Loading...
Permit CITY OF TIGARD MASTER PERMIT rill 11. . COMMUNITY DEVELOPMENT Permit#: MST2018-00010 1-t GAp,fl 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 01/11/2018 Parcel: 2S103CC11100 Jurisdiction: Tigard Site address: 12285 SW WHISTLER'S LN Subdivision: WHISTLERS WALK Lot: 58 Project: GLAVCIC Project Description: Solar photovoltaic system. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $17,557.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Drains: 0 Bckflw Prevntr: 0 Catch Basins: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add!500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Roof top PV system Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 0 Owner: Contractor: DRAGAN GLAVCIC A AND R SOLAR CORP Required Items and Reports(Conditions) 12285 SW WHISTLER'S LN 1887 SW MILPORT RD TIGARD,OR 97223 MILWAUKIE,OR 97222 PHONE: 503-999-3336 PHONE: 503-939-7663 FAX: Total Fees: $363.69 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification C-nter. Those rules are set forth in OAR 952-001-0010 through SOAR 952-001-0090. You may•• - a copy ofth rules or direct questions to OUNC by calling •• - 1987 or 1.800.332.2344. . �/ Issued By: �� Permittee ig':ture: V ,-,_, C,----------- :: 1603.639.4175 503.639.4175 by 7:00 a.m.for the next ay. table inspection :-te. This permit card shall be kept in a conspicuous place on the job site until completio of the project. Approved plans are required on the job site at he time of each inspection. Building Permit Application residential ( ; v 1 , FOR OFFICE LSE O'NE1' City of Tigard Received 8I Permit No.: 111111 ie 13125 SW Hall Blvd.,Tigard,OR 97223 JAN I Date/By: f �r� � -.� � el ■ Plan Review rl Phone: 503.718.2439 Fax: 503.598.1960 '-)Q.�J b Other Permit: ti �-y B Date/By: I-I R.I) Inspection Line: 503.639.4175 C I &_S t(,.r Date Ready/By: Juris: la See Page 2 for Internet: www.tigard-or.gov tt D �t I`) `otified/Method: / ��1�,��y"' t���lt�€�.+ 4 7/ /IT I Supplemental Information 0 New construction 0 Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ®Addition/alteration/replacement 0 Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION ""%" " work indicated on this application. ® 1-and 2-family dwellingValuation: $17,557.00 0 Commercial/industrial ❑Accessory building ❑Multi-family Number of bedrooms: ❑Master builder 0 Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: I. _.. Job site address:12285 SW Whistlers Lane New dwelling area: square feet City/State/ZIP:Tigard,OR 97223 Garage/carport area: square feet Suite/bldg./apt.no.: Project name:Dragon Glavcic Covered porch area: square feet Cross street/directions to job site:SW 121ST Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: 1 Lot no.: Permit fees*are based on the value of the work performed. . Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. Installation OF 5.4 kW Photovoltaic system on roof Valuation: $ i ,, �r — - — .- 01‹ Existing building area: square feet �.. ' �� ••-•-• New building area: square feet - 0 PROPERTY OWNER 0 TENANT Number of stories: Name:Dragan Glavcic Type of construction: Address:12285 SW Whistlers Lane Occupancy groups: City/State/ZIP:Tigard,OR 97223 _ _ Existing: Phone:(503 )999-3336 Fax:( ) New: t..4 APPLICANT 0 CONTACT PERSON BUILDING PERMIT FEES* Business name:A&R Solar (Please rekrto!ce schedule) Structural plan review fee(or deposit): Contact name:Tina Kayser Address: 1887 SE Milport RD -- FLS plan review fee(if applicable): City/State/ZIP:Milwaukie OR 97222 Total fees due upon application: Phone:(503)939-7663 Fax::( ) Amount received: E-mail:permits@a-rsolar.com PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* CONTRACTORCommercial and residential prescriptive installation of roof-top mounted Photo Voltaic Solar Panel System. Business name:A&R Solar Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address:1887 SE Milport RD Solar Installation Specialty Code checklist. City/State/ZIP:Milwaukie OR 97222 Permit Fee(includes plan review $180.00 and administrative fees): Phone:(503)420-8680 Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lic.:207641 h l9 Total fee due upon application: $201.60 Authorized si • This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name Tina Kayser Date:Fir *Fee methodology set by Tri-County Building Industry Service Board. I:\Building\Permits\BUP-RESPernitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) Electrical Permit Application ,C 4 FOR OFFICE I SF.ONLY City of Tigard Received LPTBMIMI Il 's 13125 SW Hall Blvd.,Tigard,OR 97223 Plan R : f L� ' Phone: 503.718.2439 Fax: 503.598.1960`� ' r���i Plan Review Date/I3Related Permit#: T I t ,.a G P Inspection Line: 503.639.4175 Internet: www ti ard-or. ov x" ReadyDate/By: kris: g g k d G iT a�ei n s 9 See Page 2 for f x a� 9�,A�^��� Notified/Method: Supplemental Information 0 New construction ®Addition/alteration/re lacement Please check all that apply Addition/alteration/replacement pp y(submit 2 sets of plans w/items checked): 0 DemOhlitlODemolition ❑Other: ❑Service or feeder 400 amps or more ❑Building over three stories. ,, where the available fault current 13Marinas and boatyards. F a� ,, exceeds 10,000 amps at 150 volts or ID Floating buildings. ® 1-and 2-family dwelling 0 Commercial/industrial 0 Accessory building less to ground,or exceeds 14,000 ❑Commercial-use agricultural EI Multi-family ❑Master builder ❑Other amps for all other installations. buildings. fa Ire pump.g y} tiu .�. t�l k r ET L, ,M frInstallation at ly 150 KVA or � ., � :� ❑Emergency system. larger separately derived Job#: Job site address:12285 SW Whistlers Lane ❑Addition of new motor load of system. 100HP or more. ❑"A","E","1-2","1-3", City/State/ZIP:Tigard OR 97223 ❑Six or more residential units. occupancy. ❑Health-care facilities. ❑Recreational vehicle parks. Suite/bldg./apt.#: I Project name:Glavcic ❑Hazardous locations. CI Supply voltage for more than ❑Service or feeder 600 amps or more. 600 volts nominal. Cross street/directions to job site:SW 121"Ave r .tee. 271" N Description Qty. Each Total * New residential single-or multi-family dwelling unit. Subdivision: I Lot#: Includes attached garage. Tax map/parcel#: 1,000 sq.ft.or less 168.54 4 t Ea.add'l 500 sq.ft.or portion 33.92 1 � Limited energy,residential Installation of 5.400 kW Photovoltaic system on roof (with above sq.ft.) 75.00 2 Limed enegwimthulaib -ovmilqy ft.) 75.00 2 t a ;t•'' V . �,Y k �Y4 SRvewasbEedregrys installation,a❑ SeeonP,aagnd2/or relocation Name:Dragan Glavcic 200 amps or less 100.70 2 Address:12285 SW Whistlers Lane 201 amps to 400 amps 133.56 2 City/State/ZIP:Tigard OR 97223 401 amps to 600 amps 200.34 2 601 amps to 1,000 amps 301.04 2 Phone:(503)999-3336 I Fax:( ) Over 1,000 amps or volts 552.26 2 Email: Temporary services or feeders installation,alteration,and/or relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 I intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 r :: y5 Branch circuits—new,alteration,or extension,per panel A.Fee for branch circuits with Business name:A&R Solar above service or feeder fee, each branch circuit 7.42 2 Contact name:Tina Kayser B.Fee for branch circuits without Address:1887 SE Milport RD service or feeder fee,first branch circuit 56.18 2 City/State/ZIP:Milwaukie OR 97222 Each add'1 branch circuit 7,42 2 Miscellaneous(service or feeder not included) Phone:(503)420-8680 Fax: :( Each manufactured or modular Email:permits@a-rsolar.com dwelling,service and/or feeder 67.84 2 Reconnect only 67.84 2 ;.,y, ,; DN :OR. .ff :::::-.711::-.4,,,, '"' ,,, . s Pump or irrigation circle 67.84 2 Business name:A&R Solar Sign or outline lighting 67.84 2 Address:1887 SE Milport RD Signal circuits)or limited-energy 12 See Page 2 panel,alteration,or extension. g 2 City/State/ZIP:Milwaukie OR 97222 Each additional inspection over allowable in any of the above Additional inspection(1 hr min) 66.25/hr Phone:(503)420-8680 Fax:( ) Investigation(1 hr min) 90.00/hr Email:permits@a-rsolar.com Industrial plant(1 hr min) 78.18/hr Inspections for which no fee is CCB Lic.: 207641 Electrical Lie.: C1179 Suprv.Lic.: 54945 specifically listed(%hr mint 90.00/hr la:LECTII CM..P T''FE S y. Suprv.Electrician signature,required: f.! Subtotal: Print name: Robert NiemaVpG I Date: 01/05/18 ❑Plan Review Required(25%of permit fee): State surcharge(12%of permit fee): Authorized signature: c � vr�+ a TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within 180 Print name: Tina Kayser Date: 01/05/18 days after it has been accepted as complete. * Number of inspections allowed per permit. I:\Building\Permits\ELC_PemitApp_OLR_ERE.doe Rev 06/17/2015 440-4615T(I I/05/COM/WEB Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: al:' .._.r s, .:i,. W •' ::. .�. ~ z Descri•tion a>iartEMBIE4TMEN Fee for all residential systems combined: $75.00 Renewable electrical energy systems: 5 kva or less 100.70 _© Check Type of Work Involved: 5.01 to 15 kva 111 133.56 133.56 El Audio and Stereo Systems* 15.01 to 25 kva 200.34 _© Wind l eneration s stems in excess of 25 kva: ❑ Burglar Alarm 25.01 to 50 kva - 301.04 _© 50.01 to 100 kva 552.26 _© ❑ Garage Door Opener* >100 kva(fee in accordance ■ 552.26 -© with OAR 918-309-0040 ❑ Heating,Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 11.1 7.42 _© >100 kva—no additional charge - 0.0 _© ❑ Vacuum Systems* Each additional ins ection over allowable in an of the above: ElOther: additional inspection is 111166.25/hr Other: charted at an hourl 1 hr min —. Inspections for which no fee is ■ 90.00/hr s ecificall listed 'A hr min fttw;t a „: ; ,4 Subtotal(Enter on Page 1): Fee for each commercial system: $75.00 * Number of inspections allowed per permit. (SEE OAR 918-309-0000) Check Type of Work Involved: ❑ Audio and Stereo Systems ❑ Boiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC ❑ Instrumentation ❑ Intercom and Paging Systems ❑ Landscape Irrigation Control* ❑ Medical ❑ Nurse Calls ❑ O• utdoor Landscape Lighting* ❑ P• rotective Signaling ❑ Other: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations I:\Building\Permits\ELC_PennitApp_ELR_ERE.doe Rev 06/17/2015 City of Tigard w Building Division ;E I V E D 13125 SW Hall Blvd,Tigard, OR 97223 Phone: 503.718.2439 Fax: 503.598.1960 ' 18 TI G A R D Inspection Line: 503.639.4175 , 1 1 :A ,=, www.tigard-or.gov ga g11 4.7 D1 Ea, , ON 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 12285 SW Whistlers Lane City: Tigard OR Zip: 97223 Owner's Name: Dragan Glavcic Date: 01/05/18 Contractor's Name: A & R Solar CCB #: 207641 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation ❑ Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? ® No OSSC or ORSC for design requirements. Is the wind exposure ® Yes Wind Exposure p If"Yes", qualifies for "C" or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes ® Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? structures other than If"Yes", qualifies for above11] Yes the prescriptive path. ❑ No 1 I:/Building/Forms/Photovoltaic-Checklist.docx , Is the construction Type of material wood and does ® Yes the construction qualify If"Yes", qualifies for Construction as "conventional light ❑ No the prescriptive path. frame" construction? Is the spacing 24 inches or less? • Pre-engineered trusses. ® Yes If"Yes", qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. If"Yes", qualifies for ® Yes the prescriptive path. ❑ No Is the combined weight ® Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance ® Yes with Section 305.4(3) of If"Yes", qualifies for Elthe 2010 Oregon Solar No the prescriptive path. Code? ❑ Metal Single layer If roofing material is Roofing Check the type of ❑ of wood one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers the prescriptive path. ® of composition shingle. Is the roof mounted ® Yes Connections of solar assembly the solar assembly connected to roof If"Yes", qualifies for to the roof framing or blocking ❑ No the prescriptive path. directly? 2 I:/Building/Forms/Photovoltaic-Checklist.docx Y ❑ Yes If"Yes", qualifies for Is the gauge 26 or less? ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directly to inches Maximum 60 inches inches, qualifies for the standing seam prescriptive path. metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of If"Yes", qualifies for fastener? ❑ Yes the prescriptive path. ❑ No Is the roof decking of WSP min. 1/2"thickness, ❑ Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12" o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof ® Yes the prescriptive path. surface. ❑ No 3 I:/Building/Forms/PhotoVoltaic-Checklist.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing(rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: LG Model Number: 300S1 C-A5 Listing Agency: UL1703 4 I:/Building/Forms/Photovoltaic-Checklist.docx Electrical Permit Application FOR OFF►c►. 1 SF Oy►.v City of Tigard Received , Date/B Permit#: 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review Phone: 503.718.2439 Fax: 503.598.1960 Date/B : Related Permit#: -11C-1 R 1) Inspection Line: 503.639.4175 Ready Date/By: Juris: 0 See Page 2 for Internet: www.tigard-or.gov Notified/Method: Supplemental Information 0 New construction ®Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w/items checked): ❑Service or feeder 400 amps or more 0 Building over three stories. 0 Demolition 0 Other: where the available fault current 0 Marinas and boatyards. r CATEGORY OF CONSTRUCTION i exceeds 10,000 amps at 150 volts or 0 Floating buildings. ® 1-and 2-family dwelling 0 Commercial/industrial 0 Accessory building less to ground,or exceeds 14,000 0 Commercial-use agricultural ❑Multi-famil amps for all other installations. buildings. y ❑Master builder ❑Other: ❑Fire pump. 0 Installation of 150 KVA or ., ,- ,,, -'poi strxorrottmArioiANDAmpi ❑Emergency system. larger separately derived Job#: Job site address:12285 SW Whistlers Lane ❑Addition of new motor load of system. 100HP or more. ❑"A> "E" "1-2" "1-3" City/State/ZIP:Tigard OR 97223 0 Six or more residential units. occupancy. 0 Health-care facilities. 0 Recreational vehicle parks. Suite/bldg./apt.#: Project name:Glavcic 0 Hazardous locations. 0 Supply voltage for more than 0 Service or feeder 600 amps or more. 600 volts nominal. Cross street/directions to job site:SW 1218'Ave Description I Qty. I Each I Total New residential single-or multi-family dwelling unit. Subdivision: Lot#: Includes attached garage. Tax map/parcel#: 1,000 sq.ft.or less 168.54 4 Ea.add'l 500 sq.ft.or portion 33.92 1 ` DESCRIPTION OF WORK Limited energy,residential Installation of 5.400 kW Photovoltaic system on roof (with above sq.ft.) 75 2 Limited energy,multi-family residential(with above sq.ft.) 75.00 2 ( pRP {lvNER- Renewabgy 2 " Services or le feedersEnerinstallation,alteration,❑ SeePage and/or relocation Name:Dragan Glavcic 200 amps or less 100.70 2 Address:12285 SW Whistlers Lane 201 amps to 400 amps 133.56 2 City/State/ZIP:Tigard OR 97223 401 amps to 600 amps 200.34 2 601 amps to 1,000 amps 301.04 2 Phone:(503)999-3336 Fax:( ) Over 1,000 amps or volts 552.26 2 Email: Temporary services or feeders installation,alteration,and/or relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 I intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 R� APPLICANT [ ' 0 CONTACT PERSON ABranchFeefor circuitsbranch ci—new,rcuits alteration,with or extension,per panel . Business name:A&R Solar above service or feeder fee, each branch circuit 7.42 2 Contact name:Tina Kayser B.Fee for branch circuits without Address:1887 SE Milport RD service or feeder fee,first branch circuit 56.18 2 City/State/ZIP:Milwaukie OR 97222 Each add'l branch circuit 7.42 2 Phone:(503)420-8680 Fax:: Miscellaneous(service or feeder not included) ( ) Each manufactured or modular Email:permits@a-rsolar.com dwelling,service and/or feeder 67.84 2 Reconnect only 67.84 2 CONTRACTOR Pump or irrigation circle 67.84 2 Business name:A&R Solar Sign or outline lighting 67.84 2 Address:1887 SE Milport RD Signal circuit(s)or limited-energy panel,alteration,or extension. 0 See Page 2 2 City/State/ZIP:Milwaukie OR 97222 Each additional inspection over allowable in any of the above Additional inspection(1 hr min) 66.25/hr Phone:(503)420-8680 Fax:( ) Investigation(1 hr min) 90.00/hr Email:permits@a-rsolar.com Industrial plant(1 hr min) 78.18/hr Inspections for which no fee is CCB Lic.: 207641 Electrical Lic.: C1179 Suprv.Lie.: 54945 specifically listed(V hr min) 90.00/hr Su rv.Electrician si ELECTRICAL PERMIT FEES p gnature,required: Subtotal: Print name: Robert Niemat 'gyp Al,,,„,,,, Date: 01/05/18 0 Plan Review Required(25%of permit fee): State surcharge(12%of permit fee): Authorized signature: L �� 7<*--40/—* -- TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within 180 Print name: Tina Kayser Date: 01/05/18 days after it has been accepted as complete. * Number of inspections allowed per permit. I:\Building\Permits\ELC_PermitApp_ELR_ERE.doc Rev 06/17/2015 440-4615T(11/05/COM/WEB Electrical Permit Application—City of Tigard * Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: srliE TIAL `VU RK ONLY; Fee for all residential systems combined: $75.00 De Renewable electrical energy systems: Check Type of Work Involved: 5 kva or less 100.70 2 5.01 to 15 kva X 133.56 133.56 2 ❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: ❑ Burglar Alarm 25.01 to so kva 301.04 2 ❑ Garage Door Opener* 50.01 to 100 kva 552.26 2 >100 kva(fee in accordance with OAR 918-309-0040) 552.26 2 ❑ Heating,Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7.42 3 ❑ Vacuum Systems* >100 kva-no additional charge 0.0 3 Each additional inspection over allowable in any of the above: El Other: Each additional inspection is 66.25/hr charged at an hourly(1 hr min) Inspections for which no fee is s.ecificall listed Vs hr min 90.00/hr p "ELECTRICAL PERMIT.PEER COMMERCIAL WORK GAILY`. Fee for each commercial system: $75.00 Subtotal(Enter on Page 1): I (SEE OAR 918-309-0000) * Number of inspections allowed per permit. Check Type of Work Involved: ❑ Audio and Stereo Systems ❑ Boiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC ❑ Instrumentation ❑ Intercom and Paging Systems ❑ Landscape Irrigation Control* ❑ Medical ❑ Nurse Calls ❑ Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations 1:\Building\Permits\ELC_PennitApp_ELR_ERE.doe Rev 06/17/2015