Loading...
Plans (69) GENERAL NOTES AERIAL VIEW t 1. ALL WORK SHALL COMPLY WITH 2017 NATIONAL ELECTRIC CODE(NEC),2015 :r ° } = 1 _ INTERNATIONAL RESIDENTIAL CODE(IRC),2014 NATIONAL BUILDING CODE(NBC),2015 . ' `' ,,,,s �.. 3''a • ;, s INTERNATIONAL BUILDING CODE(IBC),2015 INTERNATIONAL PLUMBING CODE(IPC),AND # x t e ALL STATE AND LOCAL BUILDING,ELECTRICAL,AND PLUMBING CODES. { }s 4t. � , r a744 +� ° 2. DRAWINGS HAVE BEEN DETAILED ACCORDING TO UL LISTING REQUIREMENTS. :,,: Iv 0 V 2017 1220 S.630E STE.430 AMERICAN FORK.UT 84003 �.,.�! Y .3F d it.-2Aft y i BUILDING 183r way 8003774480 • s WWW.BLUERAVENSOLAR.COM SITE NOTES $ - R 1. A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. ) CONFIDENTIAL-THE INFORMATION 2. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS AN UTILITYit ti 1. HEREIN• CONTAINED SHALL NOT BE ': s USED FOR THE BENEFIT OF INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. y T 3. THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING,MECHANICAL,OR • ) ANYONE EXCEPT AB BLL NOR SHALL IT BUILDING ROOF VENTS. : y BE DISCLOSED IN WHOLE OR IN 4. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL k 3 PART TO OTHERS OUTSIDE EQUIPMENT WILL BE PROVIDED AS PER SECTION[NEC 110.26] ? µ RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE 5. THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE x4 ° ; _ �- - SALE AND USE OF THE RESPECTIVE BETWEEN THE GROUNDING ELECTRODE AND THE PANEL(OR INVERTER)IF SMALLER THAN#6 s ! • " EQUIPMENT,WITHOUT THE z s .# }# f ' AWG COPPER WIRE PER NEC 250-64B.THE GROUNDING ELECTRODE CONDUCTOR WILL BE - "� � �€ �,„ � ] � � WRITTEN PERMISSION OF CONTINUOUS,EXCEPT FOR SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT PER 3 k E ":: �._. BLUERAVENSOLAR LLC. NEC 250.64C. ;IIIIIIIIIIII•11 > e [ 1 � ' 6. ROOF COVERINGS SHALL BE DESIGNED,INSTALLED,AND MAINTAINED IN ACCORDANCE WITH ° • W O O U THIS CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF '' , 40 r z "„ � • i , p.:. W Z COVERING SHALL SERVE TO PROTECT THE BUILDING OR STRUCTURE. `7 ',* } ��� [ .'; ';' C� D H o d 7. RIGID CONDUIT(AND/OR NIPPLES)MUST HAVE A PULL BUSHING TO PROTECT WIRES. ,; a I 1- H#L =r<` Q Y Q U ~ oo 8. BOLTED CONNECTION REQUIRED IN DC DISCONNECTS ON THE WHITE GROUNDED E � • C C'Q CONDUCTOR(USE POLARIS BLOCK OR NEUTRAL BAR) w ••• ° LC) I- W O 4111 9. ANY CONNECTION ABOVE LIVE PARTS MUST BE WATERTIGHT.REDUCING WASHERS & - O co Zo Q DISALLOWED ABOVE LIVE PARTS,MEYERS HUBS RECOMMENDED • p • : ' 10. UV RESISTANT CABLE TIES(NOT ZIP TIES)USED FOR PERMANENT WIRE MANAGEMENT OFF w• LULL U THE ROOF SURFACE IN ACCORDANCE WITH NEC 110.2,110.3(A-B).300.4 , 4 • W 11.SOLADECK JUNCTION BOXES MOUNTED FLUSH W/ROOF SURFACE TO BE USED FOR WIRE • " ° o ; s .`. r: t fr -J MANAGEMENT AND AS FLASHED ROOF PENETRATIONS FOR INTERIOR CONDUIT RUNS. s PIIIICO ��s � 4 a. SOLAR CONTRACTOR 1. MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730. C , 2. IF APPLICABLE,MODULE GROUNDING LUGS MUST BE INSTALLED AT THE MARKED GROUNDING cn s i1, LUG HOLES PER THE MANUFACTURERS'INSTALLATION REQUIREMENTS. • 3. AS INDICATED BY DESIGN,OTHER NRTL LISTED MODULE GROUNDING DEVICES MAY BE USED {" - s a • }. IN PLACE OF STANDARD GROUNDING LUGS AS SHOWN IN MANUFACTURER DOCUMENTATION s•.... •, AND APPROVED BY THE AHJ. ASCE 7-10 WIND SPEED: 110 MPH OCCUPANCY R3 SHEET INDEX °' 4. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND GROUND SNOW LOAD: 10 PSF ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. CONSTRUCTION - V-B PV1 - COVER SHEET OFFICE COPY Q 5. CONDUIT POINT OF PENETRATION FROM EXTERIOR TO INTERIOR TO BE INSTALLED AND EXPOSURE CATEGORY: C Z - . ZONING: RESIDENTIAL PV2 - PROPERTY PLAN SEALED WITH A SUITABLE SEALING COMPOUND. SEISMIC DESIGN CATEGORY: D N W 6. DC WIRING LIMITED TO MODULE FOOTPRINT W/ENPHASE AC SYSTEM. PV3 - SITE PLAN I- U) N N 7. ENPHASE WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/ PV4 EQUIPMENT & ATTACHMENT DETAIL < 1-15 rn u) SUITABLE WIRING CLIPS. SCOPE OF WORK PV5 - ELECTRICAL SINGLE LINE DIAGRAM a� o o 8. MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR o c Y W 0 VOC UNLESS NOT AVAILABLE. DC SYSTEM SIZE: 4.56 kW DC PV6 ELECTRICAL CALCULATIONS o 2 1- as 9. ALL INVERTERS,MOTOR GENERATORS,PHOTOVOLTAIC MODULES,PHOTOVOLTAIC PANELS, ROOF TYPE: Comp Shingle & STRING DIAGRAM Z ct u) O } AC PHOTOVOLTAIC MODULES,DC COMBINERS,DC-TO-DC CONVERTERS,SOURCE CIRCUIT MODULES: (16) Sunmodule Plus SW 285M Black PV7 - MBD CALCS. (IF NEEDED) w U) a) COMBINERS,AND CHARGE CONTROLLERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER PV8 LABELS & LOCATIONS N SYSTEM WILL BE IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4(B). INVERTER(S): Enphase IQ6 60 2 US,- - = 0 10. ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. PV9 - STRING & SE OPTIMIZER RACKING: Iron Ridge XR10 PV Mounting & Racking System PV10 - PLACARD (IF NEEDED - NEC 690.56(8)) DRAWING BY EQUIPMENT LOCATIONS Ryan Sperry 1. ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY[NEC 110.26]. ANCHORED ON MAX 48 INCH CENTERS USING UL LISTED RACKING CITY OF TTG A R!l 2. EQUIPMENT INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING SYSTEM TO SPEC. �.i 1 I / IJriLW TEMPERATURE AS SPECIFIED BY[NEC 690.31 (A)-(B)]AND[NEC TABLE 310.15(B)]. REVI FO.R CODE COMPLIANCE DATE 3. ADDITIONAL AC DISCONNECTS SHALL BE PROVIDED WHERE THE INVERTER IS NOT ADJACENT November 1, 2017 TO THE UTILITY AG DISCONNECT,OR NOT WITHIN SIGHT OF THE UTILITY AC DISCONNECT. 3b�pr-e Approved: 4. ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING �+ OTC: I PROJECT NUMBER TO NEC APPLICABLE CODES. The e Ci Tigard and I#$ .,• ` J 45184128 5. ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE t mpf� u v shall not be Permit#; rn s-r a0 "7 01 o 4 3 WHEN APPROPRIATE. !!i A(�(ress: iC-C Lk �7 A y� r, AI �� sHEET NaME responsible for discrepancies I ' 1 COVER !Ely: EET which may appear herein., Suite#: �-�( Date: IIS 6� `� PAGE NUMBER ION II t PV1 0 LEGEND INV INVERTER&DC DISCONNECT BLUE RAVEN 12464 Southwest Saint Andrews Lane SUB (E) SUBPANEL LC (N) LOAD CENTER 1220 S.630 E STE.430 AMERICAN FORK,UT 84003 AC AC DISCONNECT 800-377-4480 WWW.BLUE RAVEN SOLAR.COM M UTILITY METER 1 SERVICE PANEL CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF JB JUNCTION BOX ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE C COMBINER BOX RECIPIENTS ORGANIZATION. EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE FRONT OF HOME PV PV REVENUE METER EQUIPMENT,WITHOUT THE N WRITTEN PERMISSION OF BLUERAVENSOLAR LL(4-1-11) C ji FIRE SETBACK O EMT CONDUIT RUN W W O J CD lr I (TO BE DETERMINED IN FIELD) o z 't Z D 6) <Et co O N PV WIRE STRING Ur �' Q 1 CC Z 2 I__ I— W o I PROPERTY LINE U U M O <©® W ° Uw -) 07 W o SCALE: 1116"= 1'-0" 0 1:11 0 O 3' 4' 8' 16' 32' N J 0 �i %!%7,ff51e 0 LCL m 0 o 131111o o o J COCCI13o O0 MP1 m O o Q AZIMUTH:173° z PITCH:22° o ° ©©13 o O NV N j j TSRF:81% Q N N rn AZIMUTH:173° 0O oc o 0 .. cm W p PITCH:22° Z Et U) p ca 5 TSRF:84% a W co Cn cnCO U (N H 0 4 ROOF ATTACHMENTS SHALL BE SPACED NO DRAWING BY GREATER THAN 24" ON CENTER IN ANY Ryan Sperry DIRECTION WHERE LOCATED WITHIN 3' OF A ROOF EDGE, HIP, EAVE, OR RIDGE OSSC DATE 3111.5.3 ITEM 3.44 November 1, 2017 PROJECT NUMBER DC SYSTEM SIZE: 4.56 kW DC 45184128 ROOF TYPE: Comp Shingle SHEET NAME (16) Sunmodule Plus SW 285M Black PROPERTY PLAN Enphase IQ6-60-2-US,----INVERTER PAGE NUMBER REVISION PV2 0 LEGEND \e- N FRONT OF HOME INV INVERTER&DC DISCONNECT BLUE RAVEN (;;Iiii) SUB (E) SUBPANEL LC (N) LOAD CENTER 1220 S.630 E STE.430 AMERICAN FORK,UT 84003 AC AC DISCONNECT 800-377-4480 WWW.BLU E RAVENSOLAR.COM M UTILITY METER/SERVICE PANEL CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF JB JUNCTION BOX ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE C COMBINER BOX RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE PV PV REVENUE METER EQUIPMENT,WITHOUT THE AC DISCO TO BE LOCATED WRITTEN PERMISSION OF WITHIN 10' OF UTIILTY BLUERAVENSOLAR LLC. jFIRE SETBACK >- r O METER EMT CONDUIT RUN (U w O Q co M MSP (TO BE DETERMINED IN FIELD) Q U O AC 0 PV WIRE STRING < Z co O 2 I-- 1r) I— w0 C / //5-33g,/,110 •� 0 I PROPERTY LINE W 0 0 CO —) rA W SCALE: 1/8"= 1'-0" 0 D 0 0 2' 4' 8' 16' fl CO JB 0 Iffc fftc Etc Iffc 0 a) 0 cc ca J 0 N a) ffc ffc Iffc ffc 0 2 z O O O C C N LLI N JB 0 2 3 6' 0 o u) 0 MP1 O 92 = m H o AZIMUTH:173° c I§c Etc Z o co O PITCH:22° 0 w o co u co (A r- i= 0 4 Itac afcc DRAWING BY Ryan Sperry DATE November 1, 2017 MP2 AZIMUTH:173° PROJECT NUMBER DC SYSTEM SIZE: 4.56 kW DC PITCH:22° 45184128 TSRF:84/° ROOF TYPE: Comp Shingle SHEET NAME SITE PLAN (16) Sunmodule Plus SW 285M Black Enphase IQ6-60-2-US,---INVERTER PAGE NUMBER REVISION PV3 0 • PV ARRAY STRUCTURAL CRITERIA ROOF ATTACHMENTS SHALL BE SPACED NO • 0 PV MODULE PV MODULE COUNT: 16 MODULES Ridge XR10 PV RAIL GREATER THAN 24" ON # OF ATTACHMENT POINTS: 36 CENTER IN ANY r<N® ®m_ _:v_______ 4._-_,::,„:,,,,,,,:-__-_- - -4rt7/Iron ..m,. 2...__..;.._--------_;:; _ , - BLUE RAVEN ARRAY AREA: Module Count X 17.51ft2= 280.2ft2 DIRECTION WHERE ,.. ,i NN LOCATED WITHIN 3' OF A 1'-11" ROOF AREA: 3269.Oft2 ROOF EDGE, HIP, EAVE, MAX. 48" MAX.' 1220 S.630E STE.430 OR RIDGE OSSC 3111.5.3 ARRAY DETAIL, FRONT VIEW AMERICAN FORK,UT 84003 % OF ARRAY/ROOF: 9.2% ITEM 3.44800-377-4480 Scale: 3/8" = 1'-0" WWW BLUERAVENSOLAR COM ARRAY WEIGHT: Module Count x 501bs = 800.OIbs ROOF TYPE: Comp Shingle DISTRIBUTED LOAD: Array Weight_Array Area =2.86 lbs/ft2 ROOF FRAMING TYPE: Manufactured Truss CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE RAFTER OR TOP CHORD SIZE: 2 x 4 USED FOR THE BENEFIT OF POINT LOAD: Array Weight:Attachments = 22.2lbs/attachment RAFTER OR TOP CHORD SPACING: 24"O.C. Iron Ridge XR10 PV RAIL ANYONE EXCEPT CEILING JOIST OR BOTTOM CHORD SIZE: 2 x 4 BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ASCE 7-10 WIND SPEED: 110 MPH EXPOSURE CATEGORY: C CEILING JOIST OR BOTTOM CHORD SPACING: 24"O.C. PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, SITE CRITERIA 10"MIN - FlashFoot2 EXCEPT IN CONNEC ON WITH THE GROUND SNOW LOAD: 10 PSF SEISMIC DESIGN CATEGORY: D 1 4„ ' SALE AND USE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE MAX WRITTEN PERMISSION OF IRONRIDGE STOPPER SLEEVE IRONRIDGE UNIVERSAL 10"MIN BLUERAVENSOLAR LLC. IRONRIDGE UNIVERSAL FASTENING OBJECT 1'-4" 2' 8" MIN o FASTENING OBJECT ��a� � '1- 1',dr PV MODULE FRAME PV MODULE FRAME MAX 3' 10"MAX 22° W w ' r O Q d1- J Ir IRONRIDGE RAIL / Q cc U O F 19 IRONRIDGE RAILA /=' 2'-8" MIN - Q D0 o) < Z °? H W O '1 ;- 3' 10"MAX coZCD ARRAY DETAIL, SIDE VIEW 01- 0 (n 0 < c° Scale: 3/8" = 1'-0" p ri U u O DETAIL, END CLAMP FRONT O DETAIL, MID CLAMP FRONT 0 m Scale: 6"= 1'-0" Scale: 6"= 1'-0" Sunmodule Plus SW 285M Black PV MODULECD PV MODULE Iron Ridge XR10 PV RAIL It It J is, to _ .. . Iron Ridge XR10 PV IRONRIDGE N N N N m RAIL Jr4--- 1' 11" 48"MAX." c MAX. Z Q _._._ ARRAY DETAIL, FRONT VIEW 0 - . N L (E) ROOF Scale: 3/8" = 1'-0" Qcn MEMBRANE ROOF TYPE:TOP ComShingleRD L U' 4 :.�j� ul� ROOF FRAMING TYPE: Manufactured Truss a) o 0' RAFTER OR CoHOSIZE: 2 x 4 O 1 ° H 9 RAFTER OR TOP CHORD SPACING: 24"O.C. z o CEILING JOIST OR BOTTOM CHORD SIZE: 2 x 4 CEILING JOIST OR BOTTOM CHORD SPACING: 24"0.C. = d H u) 4 N O Lco O I_MIRONRIDGE ""_10 to (N . Iron Ridge XR10 PV RAIL FLASHFOOT 2.5' MIN ASSEMBLY 10" MAX,\.- ---__ / DRAWING BY EMBED ., \ ---- _- Ryan Sperry at FLASHING 10"MAXA \ =, ..., 22 DATE ____10.--- � November 1, 2017 5/16"STAINLESS STEEL LAG BOLT ,_ WITH 2-1/2"MIN. EMBEDMENT � ' 1 8 AND FLAT WASHER 0/'� MIN. PROJECT NUMBER ' 1.-8" 45184128 (E) BUILDING MIN. ARRAY DETAIL, SIDE VIEW A \, _ ,.....,,,_ SHEET NAME �+ STRUCTURE Scale: 3/8" = 1'-0" EQUIP. DETAIL O DETAIL, STANDOFF PAGE NUMBER REVISION Scale: 3" = 1'-0" PV4 0 (1) 10 AWG THWN-2,COPPER,BLACK(LINE 1) 15.36 AAC (1) 10 AWG THWN-2,COPPER,BLACK(MEI) MAX 16.3€r A AC (1) 10-2 NM B W/C,COPPER MAX 15.36 A AC (1) 12-2 TC-ER,rHWN-2,COPPER MAX 15.36 A AC 240 V AC (1) 10 AWE THWN-2,COPPER,RED(LINE 2) 240 V AC (1) 10 AWE THWN-2,COPPER,RED(LINE 2) 240 V AC 240 V AC (1) 6 AWE BARE,COPPER(EEC) 111 BLUE (1) 10 A THWN-2,COPPER,WHITE(NEUTRAL) (1) 10 AWETH N-2 COPPER,GREEN(GROUND) (1) 10 AWG THWN-2,COPPER,GREEN(EGC) RAVEN (1) 3/4"EMT CONDUIT (1) 3/4"EMT CONDUIT Microln rerter VOLTAGE DROP CALCULATIONS CONDUCTOR CONDUCTOR VOLTAGE STARTING. VOLTAGE AT 1220 S.630 E STE.430 (2014 NEC CHAPTER 9 TABLE 81 (THWN-2,COPPER) IMP(A) LENGTH(Fr) DROP(V) VOLTAGE(V) END(V) %DROP AMERICAN FORK,UT 84003 F PV MODU TO MICROINVERTER 10 9.20 3 0.07 3L3 31„2 0.2296 W W W.BLU E UERA RAVEEN NSO SO LAR.COM MICROINVERTER TO JUNCTION BOX 12 15.36 20 1.22 240.0 238.8 0.51% CONFIDENTIAL-THE INFORMATION JUNCTION BOX TO COMBINER BOX 10 15,36 55 2.13 240 237.9 0...';; HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ALL CONDUIT TO BE RAN AT LEAST 7/8"ABOVE ROOF SURFACE WHERE EXPOSED TO SUNLIGHT. COMBINER BOX TO INTERCONNECTION 10 15,4 10 039 240 239.6 0.16% ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT TOTAL DROP 1.78% BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE WRITTEN PERMISSION OF (E)200A MAIN SERVICE PANEL BLUERAVENSOLAR (E)200A/2P MAIN BREAKER (E PV AC DISCONNECT >- O NON-FUSED ENPHASE IQ COMBINER (16)Sunmodule Plus SW 285M Black ,I-1-1 71" Q (E)200A/2P LOCKABLE,VISIBLE OPEN JUNCTION BOX(S) W Z F) O J 3oA,24oV,2-POLE OPTIONAL IF PV (16)Enphase 1Q6-60-2-US 1741 COMPLIANT INVERTERS 0 CO U O (E)LOADS — WIRE USED FORQ ��o— ENTIRE HOMERUN Z ° 7t. CL Z . OD moo— _N JUNCTION BOX JUNCTION BOX F— W O �/ --/(12 `- (1) CIRCUIT ��It♦� 0 ~ 00 co Z > 00 Li (N)20A/2P — (N)20A/2P A A I OF 16 MODULES w Q Q X10 I , ,/°�_, G �2 _i I -7 w W " I O G 120/240 VAC N I G G G G ^ 60HZ ll 11 LL TO UTILITY (� GRID 15 0 O O G 0) ._. ttlQ Vit- '.: J PV BREAKER TO BE LOCATED OPPOSITE END OF BUSSING FROM MAIN BREAKER e� r N R �rw (E) GROUNDING rs - .41 x a ELECTRODE Y ° L"gg''1'Aa0g'9.Wr;1J1:g4gZ4g4t'iVll'i;g.,;T„..:-.-,ig,g:1,I,,g4gSt'::-,,T,,;P;r-;;'-:, Q is y� #: ,. am '"` — •'' tea' , x v �"k# 3 9 d y-. — , - d# '. i as sd w 6. , " 4 " ' ..' � ' ' Oi: -,.: , : -c W INTERCONNECTION NOTES x .J .. o } 7r ',I! ou) 4 1. ONE OF THE METHODS THAT FOLLOWS SHALL BE USED TO DETERMINE THE RATINGS OF ° Z O BUSBARS AND PANELBOARDS. (a)THE SUM OF 125 PERCENT OF THE INVERTER(S)OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE .- N BUSBAR SHALL NOT EXCEED THE AMPACITY OF THE BUS BAR. (b)WHERE TWO SOURCES, :'„ .,.44;;T:-4.44-',..4"` a I ONE THE UTILITY AND THE OTHER AN INVERTER ARE LOCATED AT OPPOSITE ENDS OF A I • ,; •,; DRAWING BY BUSBAR THAT CONTAINS LOADS,THE SUM OF 125 PERCENT OF THE INVERTER(S)OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE Ryan Sperry BUSBAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUSBAR[NEC a .< DATE 705.12(D)(3)]. November 1, 2017 3. GROUND FAULT PROTECTION IN ACCORDANCE WITH[NEC 215.9]&[NEC 230.95] 4. ALL EQUIPMENT TO BE RATED FOR BACKFEEDING. Lt R k : . ^ # )''-, 1:',,i } PROJECT NUMBER45184128 c 1 041 20 DISCONNECT NOTES 45 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS4# " p#I OPENED THE CONDUCTORS REMAINING LIVE ARE CONNECTED TO THE • SHEET NAME .., ]` TERMINALS MARKED"LINE SIDE"(TYPICALLY THE UPPER TERMINALS) � ELEC. 3 LINE D IAC. 2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL,BE LOCKABLE,AND BE A VISIBLE-BREAK SWITCH " � I� 2 I,; PAGE NUMBER REVISION 3. DC CURRENT CONDUCTORS ARE TO REMAIN OUTSIDE OF BUILDING PRIOR TO EITHER A FUSEABLE SOURCE CIRCUIT " "''"°""" '" PV5 MODULESPECIFICATIONS Sunmodule Plus SW 285M Black DESIGN LOCATION AND TEMPERATURES CONDUCTOR SIZE CALCULATIONS RATED POWER(STC) 285 W TEMPERATURE DATA SOURCE ASHRAE 0.4%HIGH TEMP MICROINVERTER TO MAX.SHORT CIRCUIT CURRRENT(ISC)= 15.36 A DC \Or- MODULE VOC 39.7 V DC STATE Oregon JUNCTION BOX MAX.CURRENT(ISC X1.25)= 19.20 A DC MODULE VMP 31.3 V DC CITY Tigard CONDUCTOR(TC-ER,(90°C))= 12 AWG BLU E RAVEN MODULE IMP 9.2 A DC WEATHER STATION PORTLAND INTERNATIONAL AP CONDUCTOR RATING= 30 A MODULE ISC 9.84 A DC ASHRAE EXTREME LOW TEMP(°C) -6 AMB.TEMP.AMP.CORRECTION= 0.91 VOC CORRECTION(voC) -0.31 °C ASHRAE 0.4%HIGH TEMP(°C) 36 ADJUSTED AMP.= 27.3 > 19.20 1220 S.630E STE.430 AMERICAN FORK,UT 84003 VMP CORRECTION(%/°C) -0.44 °C JUNCTION BOX TO MAX.SHORT CIRCUIT CURRRENT(ISC)= 15.36 ADC 800-377-4480 SERIES FUSE RATING 25 A DC SYSTEM ELECTRICALSPECIFICATIONS CIR 1 CIR 2 CIR 3 CIR 4 CIR 5 CIR 6 COMBINER BOX MAX.CURRENT(ISC X1.25) = 19.20 A DC WWW.BLUERAVENSOLAR.COM ADJ.MODULE VOC @ ASHRAE LOW TEMP 43.5 V DC NUMBER OF MODULES PER MPPT 16 CONDUCTOR(THWN-2, (90°C) = 10 AWG CONFIDENTIAL-THE INFORMATION ADJ.MODULE VMP @ ASHRAE 0.4%HIGH TEMP 25.4 V DC DC POWER RATING PER CIRCUIT(STC) 4560 CONDUCTOR RATING= 40 A HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF TOTAL MODULE NUMBER 16 MODULES CONDUIT FILL DERATE= 1 ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT MICROINVER I tR SPECIFICATIONS Enphase IQ6-60-2-US STC RATING OF ARRAY 4560W DC AMB.TEMP.AMP.CORRECTION= 0.71 BE DISCLOSED IN WHOLE OR IN POWER POINT TRACKING (MPPT) MIN/MAX 22 - 48 V DC AC CURRENT @ MAX POWER POINT(IMP) 15.36 ADJUSTED AMP.= 28.4 > 19.20 PART TOTOOUTSIDE RECIPIENN TS ORRGGS ANIZATION, MAXIMUM INPUT VOLTAGE 48 V DC MAX.CURRENT(IMP X 1.25) 19.2 EGC MAX.CHANNEL ISC= 19.20 A DC EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE MAXIMUM DC SHORT CIRCUIT CURRENT 1.5 A DC OCPD CURRENT RATING PER CIRCUIT 20 CONDUCTOR(THWN-2,(90°C))= 10 AWG EQUIPMENT,WITHOUT THE WRITTEN PERMISSION OF MAXIMUM USABLE DC INPUT POWER 330 W MAX.COMB.ARRAY AC CURRENT(IMP) 15.4 EGC CONDUCTOR RATING= 60 A BLUERAVENSOLAR LLC. MAXIMUM OUTPUT CURRENT 0.96 A AC MAX.ARRAY AC POWER 3:-i SW AC CONDUIT FILL DERATE= 1 AC OVERCURRENT PROTECTION 20 A AMB.TEMP.AMP.CORRECTION= 0.71 L 1-1-1 ( � . 09 Z J MAXIMUM OUTPUT POWER 240 W AC PHOTOVOLATIC MODULE MARKING (NEC 690.52) ADJUSTED AMP. 42.6 > 19.20 UCC , H 0 '71- CEC WEIGHTED EFFICIENCY 97 % NOMINAL OPERATING AC VOLTAGE 240 V AC COMBINER BOX TO INVERTER RATED AMPS= 15.4 A AC Z D a) Q N- NOMINAL OPERATING AC FREQUENCY 47-68 HZ AC MAIN PV OCPD MAX.CURRENT(RATED AMPS X1.25)= 19.2 AACCD c� 2F- u7 I- W o PHOTOVOLTAIC AC DISCONNECT OUTPUT LABEL(NEC 690.54) MAXIMUM AC POWER 240 VA AC CONDUCTOR(THWN-2,(90°C)) = 10 AWG I- °° Z > AC OUTPUT CURRENT 15.36 A AC MAXIMUM AC CURRENT 15.36 A AC CONDUCTOR RATING= 40 A IU 0 11 NOMINAL AC VOLTAGE 240 VAC MAXIMUM OCPD RATING PER CIRCUIT 20 A AC CONDUIT FILL DERATE= 1 O (1) LIJ AMB.TEMP.AMP. CORRECTION= 0.91 IY J ADJUSTED AMP.= 36.4 > 19.2 0.. m a) GROUNDING NOTES STRANDED,AND BARE WHEN EXPOSED. USED TO PROTECT WIRE FROM SHARP EDGES c (13 1. A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH[NEC 690-47]AND 10. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZE ACCORDING TO[NEC 6. PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHN/THWN-2 -J [NEC 250-50]THROUGH[NEC 250-60]SHALL BE PROVIDED.PER NEC, 690.45] AND BE A MINIMUM OF#10AWG WHEN NOT EXPOSED TO DAMAGE(#6AWG INSULATED.90°C RATED,WET AND UV RESISTANT,RATED FOR 600V 0 GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND SHALL BE USED WHEN EXPOSED TO DAMAGE). 7.4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER 2 BONDED TO AT THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE, 11. GROUNDING AND BONDING CONDUCTORS. IF INSULATED,SHALL BE COLOR VOLTAGE TO GROUND MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE MEANS. -0 OR INADEQUATE,OR IS ONLY METALLIC WATER PIPING,A SUPPLEMENTAL CODED GREEN(OR MARKED GREEN IF#4 AWG OR LARGER) 8.ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION Q GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION 12. ALL CONDUIT BETWEEN THE UTILITY AC DISCONNECT AND THE POINT OF 9.VOLTAGE DROP LIMITED TO 2%FOR DC CIRCUITS AND 3%FOR AC CIRCUITS Z CONSISTING OF A UL LISTED 8 FT GROUND ROD WITH ACORN CLAMP. CONNECTION SHALL HAVE GROUNDED BUSHINGS AT BOTH ENDS. 10. NEGATIVE GROUNDED SYSTEMS DC CONDUCTORS SHALL BE COLOR CODED AS O N NLi _ 2. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN#8 AWG AND 13.SYSTEM GEC SIZED ACCORDING TO[NEC 690.47],[NEC TABLE 250.66],DC FOLLOWS: DC POSITIVE-RED(OR MARKED RED). DC NEGATIVE-GREY(OR MARKED CO NO GREATER THAN#6 AWG COPPER AND BONDED TO THE EXISTING GROUNDING SYSTEM GEC SIZED ACCORDING TO[NEC 250.166],MINIMUM#8AWG WHEN GREY) N 2 N a, L ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM. INSULATED.#6AWG WHEN EXPOSED TO DAMAGE. 11.POSITIVE GROUNDED SYSTEMS DC CONDUCTORS COLOR CODED: IZ' a) O 2 U 3. PV SYSTEM SHALL BE GROUNDED IN ACCORDANCE TO[NEC 250.21],[NEC TABLE 14. EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES. DC POSITIVE-GREY(OR MARKED GREY), DC NEGATIVE-BLACK(OR MARKED BLACK) 0 mc ;. C3) W a 250.122], AND ALL METAL PARTS OR MODULE FRAMES ACCORDING TO[NEC EQUIPMENTS,AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN 12.AC CONDUCTORS>4AWG COLOR CODED OR MARKED: I-LZ Cl) C) 690.46]. ACCORDANCE WITH 250.134 OR 250.136(A)REGARDLESS OF VOLTAGE. PHASE A OR L1-BLACK,PHASE B OR L2-RED, PHASE C OR L3-BLUE,NEUTRAL- - >- Y 4. MODULE SOURCE CIRCUITS SHALL BE GROUNDED IN ACCORDANCE TO[NEC WHITE/GRAY W 1:2Cl) 690.42]. WIRING&CONDUIT NOTES "USE-2 IS NOT INDOOR RATED BUT PV CABLE IS RATED THWN/THWN-2 AND MAY N 0, 0 It 5. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT 1.ALL CONDUIT SIZES AND TYPES, SHALL BE LISTED FOR ITS PURPOSE AND BE USED INSIDE CO -) ,- I- 0 - THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDED CONDUCTOR APPROVED FOR THE SITE APPLICATIONS "USE-2 IS AVAILABLE AS UV WHITE DRAWING BY TO ANOTHER MODULE. 2.ALL PV CABLES AND HOMERUN WIRES BE TYPE USE-2,AND SINGLE-CONDUCTOR 13. IF CONDUIT DETERMINED TO BE RAN THROUGH ATTIC IN FIELD THEN CONDUIT WILL Ryan Sperry 6. EACH MODULE WILL BE GROUNDED USING THE SUPPLIED CONNECTIONS POINTS CABLE LISTED AND IDENTIFIED AS PV WIRE,TYPE TC-ER,OR EQUIVALENT; ROUTED TO BE EITHER EMT, FMC,OR MC CABLE IF DC CURRENT COMPLYING WITH NEC 690.31,NEC IDENTIFIED IN THE MANUFACTURERS INSTALLATION INSTRUCTIONS. SOURCE CIRCUIT COMBINER BOXES AS REQUIRED 250.118(10). DISCONNECTING MEANS SHALL COMPLY WITH 690.13 AND 690.15 7. ENCLOSURES SHALL BE PROPERLY PREPARED WITH REMOVAL OF PAINT/FINISH 3.ALL CONDUCTORS AND OCPD SIZES AND TYPES SPECIFIED ACCORDING TO[NEC 14.CONDUIT RAN THROUGH ATTIC WILL BE AT LEAST 18"BELOW ROOF SURFACE DATE AS APPROPRIATE WHEN GROUNDING EQUIPMENT WITH TERMINATION 690.8] FOR MULTIPLE CONDUCTORS COMPLYING WITH NEC 230.6(4)AND SECURED NO GREATER THAN 6'APART PER NEC November 1, 2017 GROUNDING LUGS. 4.ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE 330.30(B). 8. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE.AND DERATED ACCORDING TO[NEC TABLE 310.15(B)(2)(a), NEC TABLE 310.15(B)(3)(a), PROJECT NUMBER GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR DIRECT &NEC 310.15(B)(3)(c)] 45184128 BURIAL. 5.EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2,90°C RATED,WET AND UV 9. GROUNDING AND BONDING CONDUCTORS SHALL BE COPPER,SOLID OR RESISTANT,AND UL LISTED RATED FOR 600V,UV RATED SPIRAL WRAP SHALL BE SHEET NAME I ELEC. CALCS. PAGE NUMBER REVISION PV6 0 LABEL1 LABEL AT EACH DIRECT CURRENT JUNCTION BOX,COMBINER R AT DIRECT-CURRENT EXPOSED COVERS ENCLOSURES Al BOX,DISCONNECT,AND DEVICE WHERE ENERGIZED JUNCTION BOXES,AND OTHER WIRING METHODS:SPACED ATMAXIMUM 10FT SECTION ORWARNING PH T1TI UNGROUNDED CONDUCTORS MAY BE EXPOSED DURINGPOWER WHERE SEPARATED BY ENCLOSURES,WALLS,PARTITIONS,CEILINGS,OR FLOORS. BLUE RAVEN ELECTRIC SERVICE E OWE SOURCE [NEC 690.31(G)(3&4)] 9�MR�� SHOCK HHAZARD [NEC.690.35(F)] THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM 1220 S.630E STE.430 AMERICAN FORK,UT 84003 ARE UNGROUNDED AND SYSTEMSOLAR PV LABEL 8 LABEL 10 MAY BE ENERGIZEDyam R: I PPED FOR PV SYSTEMS THAT SHUT DOWN THE R - I Li 1 L• PDC g ,' SIGN LOCATED AT RAPID SHUT DOWN 800-377-4480 RAND `1 ARRAY AND CONDUCTORS LEAVING THE qWWW.BLUERAVENSOLAR.COM '' ARRAY: . V{ ` .` DISCONNECT SWITCH[NEC 690.56(C)(3)]. TURN RAPID SHUTDOWN SIGN TO BE LOCATED ON OR NO MORE CONFIDENTIAL-THE INFORMATION SWITCH TOTHE THAN 3 FT AWAY FROM SERVICE SC <..,AF L")\J .; ., -'M HEREIN CONTAINED SHALL NOT BE LABEL 2 Y?FF'POSITIONTQsmasme PHOTOVOLTAIC SYSTEM FOR PV DISCONNECTING MEANS WHERE ALL SHUTDOWN PV SYSTEM DISCONNECTING MEANS TO WHICH THE USED FOR THE BENEFIT OF PV SYSTEMS ARE CONNECTED AND ANYONE EXCEPT BLUE RAVEN DISCONNECT TERMINALS OF THE DISCONNECTING MEANS MAY BE AND REDUCEaik SHALL INDICATE THE LOCATION OF ALL SOLAR NOR SHALL IT BE DC DISCONNECT ENERGIZED IN THE OPEN POSITION. SHOCK DISCLOSED IN WHOLE OR IN PART [NEC 690.13(8).NEC 705.22] „_„INTHEARRAY ,,, IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION LABEL 11 TO OTHERS OUTSIDE RECIPIENTS RATED MPP CURRENT AMPS [NEC (ONLY IF 3 OR MORE SUPPLY SOURCES TO ORGANIZATION,EXCEPT IN A BUSBAR) CONNECTION WITH THE SALE AND THIS EQUIPMENT FED BY MULTIPLE SIGN LOCATED AT LOAD CENTER IF IT USE OF THE RESPECTIVE RATED MPP VOLTAGE VOLTS SOURCES.TOTAL RATING OF ALL CONTAINS 3 OR MORE POWER SOURCES. EQUIPMENT,WITHOUT THE MAX SYSTEM VOLTAGE VDCLABEL 9 OVERCURRENT DEVICES,EXCLUDING [NEC 705.12(D)(2)(3)(C)] WRITTENPERMISSION SOLAR OF BLUE SOLAR PV SYSTEM EQUIPPED FOR PV SYSTEMS THAT ONLY SHUT DOWN MAIN SUPPLY OVERCURRENT MAX CIRCUIT CURRENT AMPS WITH RAPID SHUTDOWN CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE DEVICE,SHALL NOT EXCEED L >- L FY O TURN RAPE)SHUTDOWN SWITCH THAN 3 FT AWAY FROM SERVICE AMPACITY OF BUSBAR. LU W d' 0 Q d- TOTFE'CfFRC.S d ®TO SHUT 001,0400MX.ICTORS - _ DISCONNECTING MEANS TO WHICH THE 0Z d' H —U LABEL 3 otrisEETHE�RAY PV SYSTEMS ARE CONNECTED AND CO o a •• I IF I CT CLIRREI IT AT EACH DC DISCONNECTING MEANS,INCLUDING THE CONDUCTORSWITH�4 SHALL INDICATE THE LOCATION OF ALL z D C5) Q1/4'1 r- DC DISCONNECT AT THE INVERTER. THEARRAYREMAIJWEI I IDENTIFIED RAPID SHUTDOWN SWITCHES < (0 I CC Z c"2 PhOTOVaTAK ROWER SOURCE [NEC 690.53,NEC 690.13(B)] BE DIN IF NOT AT THE SAME LOCATION. 2 F, 14) E— LU O [NEC 690.56(C)(1)(B)] f— M z > c) 1 MAXIV TAGE VDC 0 ° < MAX CIRCUIT CURRENT AMPS LU ,I 0 W I J LABEL 4 Q. m PHOTOVOLTAIC SYSTEM AT POINT OF INTERCONNECTION,MARKED AT AC AC r DISCONNECTING MEANS. A AC DISCONNECT At [NEC 690.54,NEC 690.13(B)] a) RATED AC OUTPUT CURRENT A c NOMINAL OPERATING AC VOLTAGE V 0 m LABEL 5 C AT POINT OF INTERCONNECTION FOR EQUIPMENT Z Q CONTAINING OVERCURRENT DEVICES IN CIRCUTS SUPPLYING POWER TO A BUSBAR OR CONDUCTOR 0 1 c W • DUAL POWER SUPPLY SUPPLIED FORM MULTIPLE SOURCES,EACH SERVICE LABELING DIAGRAM: i— c N N EQUIPMENT AND ALL ELECTRIC POWER PRODUCTION < ., N SOURCES: UTILITY GRID AND SOURCE LOCATIONS. MAIN SERVICE PANEL PV SOLAR ELECTRIC SYSTEM [NEC 705.10.NEC 705.12(D)(3)[ a) o 2 0 0 m W 0 LABEL 6 EXISTING SUB PANEL PV COMBINER INVERTER(S) Z il co Q } ii PLACED ADJACENT TO THE BACK-FED BREAKER (IF WHERE POINT OF SUBPANEL- LU -E -2 Cl) a. FROM THE INVERTER IF TIE IN CONSISTS OF LOAD O INTERCONNECTION IF USED TO COMBINE H W ' ' 0 co SIDE CONNECTION TO BUSBAR. \ O S MADE) AC DISCONNECT PV OUTPUT CIRCUITS (/) N— 0 d. I TER OUTPUT CONNECTION [NEC 705.12(D)(2)(3)(6)] 5 DO NOT RELOCATE E._ o o ® O O O 0 DRAWING BY THIS OVERCURRENT � Ryan Sperry DEVICE 0 OR 0 0 0 4 Ac JUNCTION BOX DATE (0 2 OR COMBINER BOX November 1, 2017 11 DC 0 0 � 1 PROJECT NUMBER LABELING NOTES: (ONLY IF PV (ONLY IF PV 0 0 0 45184128 1. LABELING REQUIREMENTS BASED ON THE 2017 NATIONAL ELECTRIC CODE.OSHA STANDARD INTERCONNECTIONSINTERCTSNECTIOD L�// �J 19010 145.ANSI Z535. CONSISTS OF LOAD CONSISTS OF LOAD �� 10 0 0 2. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. SIDE BREAKER) SIDE BREAKER) SHEET NAME 3. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED[NEC INTEGRATED DC DISCONNECT LABELS 110.21] 4. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8",WHITE ON RED BACKGROUND:REFLECTIVE, *ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL REPRESENATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PAGE NUMBER REVISION AND PERMANENTLY AFFIXED[IFC 605.11.1.1] PRESENTED MAY VERY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON PV5 OF 3 LINE DIAGRAM. PV5 LINE DIAGRAM TO REFLECT ACTUAL P`V�p REPRESENTATION OF PROPOSED SCOPE OF WORK. U FRONT OF HOME BLUE RAVEN 1220 S.630 E STE.430 vc AMERICAN FORK,UT 84003 800-377-4480 W W W.BLU ERAVENSO LAR.COM CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE J B USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION. EXCEPT IN CONNEC TION WITH THE C`c l`c' l ' /RC SALE AND USE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC LLJ LLI 0Z't 0071-11 . zDOff) < - ~ < 0 d- cc Z o? 2F I— LI0r-A0 C jC C CC �1-jpUr) pU � °o -, U w O D CC _I 0_ CO a) c MP1 as AZIMUTH:173° [� cn PITCH:22° J U a) c Z Q c O 0co) N N rn EACCC CC O 'LJ_ '-C) 2 2 0 c 0) 1.11 c v Z Q co O } U c -2 u) � U) CO O) 0 CO MP2 VJ -) N- ~ 0 4 AZIMUTH:173° DRAWING BY PITCH:22° Ryan Sperry /C /C DATE November 1, 2017 PROJECT NUMBER 45184128 SHEET NAME SE Serial Layout PAGE NUMBER REVISION PV9 0 ! CAUTION ! BLUE RAVEN POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED SOLAR ARRAYS WITH SAFETY DISCONNECTS AS SHOWN: AMERCANFORK UT 84003 800-377-4480 MAIN DISTRIBUTION WWW BLUERAVENSOLAR.COM UTILITY DISCONNECT N CONFIDENTIAL-THE INFORMATION j� N lir HEREIN CONTAINED SHALL NOT BE iiiolill (\v'� J� USED FOR THE BENEFIT OF ANYONE EXCEPT 7 BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE I EQUIPMENT,WITHOUT THE AC DISCONNECT 0 WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. WI O ©gym wz 0J � ©� QWoo UOr,-' AC COMBINER �©©© z 0 Q cco Q O a z in I— w o Olipir„ CIA oo z > O wHin w 06 C�� —, w w COAL O D PV ARRAY(S)111 � co a) 12464 Southwest Sal Andrews Lane, Tigard Oregon 97224 J a) z DIRECTORY 11°117 ��► O Fs 'I- w PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF H C N N THE SERVICE DISCONN NG MEANS AND THE PHOTOVOLTAIC 45 CS 0) SYSTEM DISCONNECTI O c cn w o WHERE THE INVERTS` ,A REMOTELY LOCATED FROM EACH z (2c° o H OTHER, A DIRECTORY I'- :LL BE INSTALLED AT EACH DC PV w Y SYSTEM DISCONNECTI 1 ANS, AT EACH AC DISCONNECTING TA N a U MEANS, AND AT THEM 4 SERVICE DISCONNECTING MEANS cn o SHOWING THE LOCATIONALL AC AND DC PV SYSTEM DRAWING BY DISCONNECTING MEAN E BUILDING. Ryan Sperry ALTERNATE POWER SOUR PLACARD SHALL BE PLASTIC ENGRAVE DATE IN CONTRASTING COLO" t THE PLAQUE. THIS PLAQUE WILL BE November 1, 2017 ATTACHED USING AN A ' 4VED METHOD. IF EXPOSED TO PROJECT NUMBER SUNLIGHT, IT SHALL BE V RESISTANT. ALL PLAQUES AND SIGNAGE 45184128 WILL BE INSTALLED ASUIRED BY THE NEC. [NEC 690.56(B)] [NEC 705 SHEET NAME PLACARD PAGE NUMBER REVISION PV10 0