Report (61) d7S,2 )7!7-- �a7 7 S14 RECEIVED American Security Alarms A Secure Pacific Company AUG 31 2017 8220 N. Interstate Ave., Portland, OR 97217 CITYOF TIGARD UII..DINC DIVISION PROPOSAL COMMERCIAL FIRE ALARM SYSTEM '"/t ' ATTN: Ryan Robinson August 18, 2017 Hilltop Building 3rd Floor Remodel ' '4' 7320 SW Hunziger Tigard, OR 972 We appreciate your business and hope to have the privilege of serving your fire alarm needs! The following is our recommendation: Changes to Fire Alarm System 1. Remove pull station in lobby and move to adjacent wall to the left. 2. Horn/strobe -remove wall mount in lobby and remount a new Ceiling mount Horn/strobe about 4-8 feet away in ceiling to cover Waiting room 302 and Reception 301 3. Drop elevator smoke down from current ceiling height to new lower drop ceiling in lobby 4. Mount one used wall mount (from number 2 above) at Hall 307 intersection. 5. Remove wall mount Strobe only in current break room. Mount a new ceiling mount Strobe only 5-15 feet away in the center of the new break room 6. Move existing Horn/Strobe to new wall in new Hallway 310 7. Move existing Horn/Strobe Hallway 314 5-10 feet to new wall South side of Office 316 8. Remove wall mount Horn/strobe at the Eastside Stairwell hall which currently runs North to South and Replace it with a Ceiling mount Horn/strobe in the central area of Open office 320. Move the pull station at the Eastside stairwell to the wall opposite. 9. Add one new Ceiling Mount Horn/strobe to Conference room 335 10. Remove wall mount strobe in current SW Hall. Move to wall of Office 341 • THE SECURITY PROFESSIONALS...SINCE 1970 . ' I American Security Alarms A Secure Pacific Company 8220 N. interstate Ave., Portland, OR 97217 11. Move current SW wall mt Horn Strobe to wall of Room 347 12. Move wall mount Horn/Strobe from mid-West area to the South wall of Training Room 364 13. Move wall mount in Hall 355 to new wall in Hall 355 14. Add on Sk-5495 Silent Knight Power supply to ensure proper voltage drop for the circuits on this floor. ESTIMATED PARTS AND LABOR $3603.00 ESTIMATED FIRE PERMIT ..$540.00 ESTIMATED PLAN PREPARATION, SUBMITTAL, AND MEET FIRE MARSHALL FOR FINAL TEST $990.00 ESTIMATED TOTAL $5133.00 Also needs electrician to hook up dedicated circuit to 5495. Estimated at approximately$350.00. No warranty on customer's existing wiring, sensors, controls, etc. Electrical permit will be additional cost of$125.00 Includes a full One Year Warranty on all American Security provided materials. Additional Fire Alarm Sensors or Warning Devices Maybe required by Authority having Jurisdiction &State/Local Fire Codes. Customer is responsible if any additional devices are required Electric Co. or other to run dedicated circuit to the power supply mark it red, and provide a lock on for the assigned bree r(if this is not already d e),An estimated$350 charge. 1441 Approved: ! !r Date: `'g I'IC' P2-401-1. By Rich Miller, Fire Alar Consultant, cell phone 503-706-1605 Office 503-231-0303— Please call if you have any questions r* *6'1 L THE SECURITY PROFESSIONALS...SINCE 1970 EAGLE MORTGAGE REMODEL HILLTOP BUILDING 7320 SW HUNZIGER RD. TIGARD, OR 97223 8/30/17 177 30 75 30 5 75 15/75 15/75 s••••m.mottentasta•E•soessonov. ••••••••• 0 •••••••• atax.mome. •******• 0 tainna•smxx, 0 A....... 0 N1C2 0 \ COPY HALL 310 HALL 307 BREAK HALL 303 HALL 363 OPEN STATION ROOM 305 OFFICE 320 317 15/75 15/75 15 30 15/75 75 115 Ei 110 75 15/75 15 15 .......................... ......... .1 0 “"""' ........I,„„„„,„ •16“011111111111•111.111$1110M. INKINIINE / \0 St if MP StitO813. a elela...1" "ERNE... N1C1 El HALL 329 MENS RR HALL 334 RECEPTION/ OPEN TRAINING HALL 365 OPEN HALLWAY 33 WOMENS RR CONF 335 WEST END WAITING OFFICE 342 OFFICE 350 ROOM 364 SILENT KNIGHT 5495 POWER SUPPLY EXPANDER CONTROL PANEL IN 3RD FLOOR TELCO CLOSET NAC . . . . , , ............ ::::�.i ::: i:jik';A:i::�::�::� Y T' .......... it :;Hilltop Bldg. 3rd Floor-7320 ':..:..:... .:::...:.:..A16 14/61.. ::; 24 "!, E:::illKNIT I Ifi «<... h. . :;j: € :I "7320 S5 "j' W Hunziger , 9 is <:::>::>: : :. :;:: . .,:1 RICH MILLER < :::<:»::;j. . . .:::.:.»j .: .1 Brat!: :; ac#ru'j:: 1.2 : °:::::: �195 Power Ex andel ;;;;; ,;;;;;;;;,;;,;;; Calculat9ons <.s:::a::j::jj:y:.:.. ;:.>:.y:.,j::>::>::>::>::>:>:::jj:<::::.:: ::.::.::.::..'. ,.. .... . .:. ..j:>::>::>::>;:: ;:;:.:;.;:..y<:.. P .::::::;;:, :.;> ts>:.8/30/2017 y:.;:.;:.;Vt .. :.:. ....:::::.::::.............................. an 02.1 �"fi � ....::'�.6:.. .....:..::. ii f, .r �:::':':':'�::;�`�f:`"`'`�::'ti:::sjilj::x.�a:x�ii::i:'::i.�:::is:s�:3:3:t'::::j�::i::i::j:::�::i:::::i:3:::,�::::3:::::f;::: :i:::::: ?: •:.,..,,. .:...............:...............:.....,.::,;.:::.a,.::::::::::::::::: ::::. :. :.::::::::: .:.::.:......:.:..:::..::::::::::...:.:.:::.:::.:::::.:.:::::::: :. 3r d floor telco co roo ...................... ::.:::::::.. :..:.:........... : ,..,.... ;;.;. ::':?�.,;, : :j::i:ij:::::;jjjtjjjj;::j::' ;:;:>j:;<;;.;:::yy:.; :;::<:>::j::::::::>:: j::jj>j.;':.y:.y:.y:.;';;.;:.;j;::>::» ::>::>::::::::::>::>:. ...:...:. ..:.::::::.:.::..::::._.:>:::.:jy::>::>::>:: �:�;:::::'..:::.:.;>;:.;:.y:.>::>::>.:::::.::.:..:..:...:.....:.�;.;:.;:.;:.:...::..:_:...,:.;:.;:.;:.,: :::::..:jj::j::j:«:.yy:.y.y:.y:.y:.:;.y:.:;:::.::.;:.:.>:>::j::j>:::ii >:>': c ;,;;;;,;;,;;; ;;.;;; y:. .. ..k,...........E. ..................�....... :f',4.:::::: :�fiM't":.1k.1k.4ikF..:::y;; 11._!.it:.:;;oyy;;:.;:.;:.: � ::::::::.;;�`_.::::::::: ............ 5495 Pwr �:.::.::....::::::': ...::.. ,....... wr Module ......,.........:.... .. .::::....:::ii.:!! ;..... :j::j,ykf.:.�;..... ;:.;:.;... :::::.:.;'..;: 0 2(15.. SIA ? raj:: N1C1 •O.fl00" 1.331 #14 Solid 1 '< :>'> 381 » . t5 m M:r. €`> J# .> ..:,N1C2 0.000 0.967 #14 Solid <1 .: 305 o 9.22 70 . 0.000 •,:•,;,:.0.0::=:0-00000:,i:.:::.:,,#14 Solid #s G <'..:>;... : 43 # 0.00°la . . >'<: 0.000 #14 Solid o I' �:...,:;: .'�;'1 ':n.' 0 ,{�:::... F�#+�Q .0.0010:: ,;,.,,,.:.;) .., i 5495 Aux Power ���� �. Out 0.000!: 0.00Q #12 Solid ".".::..:...,: f.t `:.::.F.:::>i> Q 0.00°10 : �s �€t't�n�:, ''''.''''''''(;/'©75; 2.503 1"t�llt'�€1>: u�� °' :A,'>: .. ,.. ,,...............::..:::._:..::::::.a'f�Tl .:�ItY .�f '.of,.�:::: .2 . ::..:::::Q,�.;:.y:..: ::::>. : :. >::> :.:: ..:.;::.»:, ��' ::. ,::::.�;;:;:.:.yyr:.:jyy..;..:>:z_iy..:::::..:.....::::::::::.5....:..;.:.y.::....... ::::::.:y�.;y:.;:.....y:.�:.::..... <.., ;.;:.;;:c ..::::.»N:. . +, ate.., y. y>;:.>: .: �:. ..:^�:..:, ;y:.;:.;'::.,,,..:.::::.:::::::,....:.....:.:::'.;:.;:.;'::;.;:. :::.,,...:..:..:::::;y:.;.;:.;..;.:. :::::::::::. Wire resistances a ' ;y;:;:»:a:;>;>:::;::j::j::jjz.......: .... .:.:.. :.y:...:';':.:>: .:::::.::.. ..::::. .:..:::.;:.:.;:.;:.;:.»::>::>::>::>::>•,,.......:>::»�::>::ky, rebased upon an ambient temperatureof 72 de rees F. Because of 9 ........:.:. ..:.:....:. ..:.. ....::.........:.::::::.. ::.. j.< the minimal difference between solid and stranded wire no differential was made. Configure Circuits Print Page II` Voltage Drop Calculations These calculations provide voltage drop calculations in three formats(Point to Point, End of Line,and Load Centering). End of line&load centering methods use only the wire gauge for the first device to source. Wire resistance is doubled for two wires(+&-). The voltage calculated @ the last device must not be lower then the manufactures listed minimum operating voltage. Point to Point End of Line Load Centering Project Name = r e n - Circuit Within Limits Circuit Within Limits Circuit Within Limits Project Address = v - - Date a Area Covered - - Circuit# End of Line Method Load Centering Method Nominal System Voltage Totals Voltage Totals Voltage Minimum Device Voltage 41,14 { Current Distance Drop Current Distance Drop Total Circuit Current � Wire Ohm's 1.331 381 3.235 1.331 381 1.618 Gauge Per 1000 End of Line Voltage 17.165 End of Line Voltage 18.782 Distance from source to 1st device Precent Drop 0.159 Precent Drop 0.079 Wire Gauge for balance of circuit Current in amps. Distance .117= 117 ma from Voltage Current Device Device Previous At Drop from Percent Candela at Rated Number Current Device Device Source Drop Device Manufacture Model# Rating Voltage Location Device 1 0.090 15 20.27 0.127 0.62% SYSTEM SENSOR pc2r ceil h/s 15/75 0.090 hallway 334 2 0.090 39 19.96 0.436 2.14% SYSTEM SENSOR p2r wall h/s 15/75 0.090 hallway 329 3 0.066 52 19.58 0.818 4.01% SYSTEM SENSOR sr strobe,wall mt 15 0.066 womens rr 4 0.090 23 19.42 0.977 4.79% SYSTEM SENSOR pc2rl ceil h/s 30 0.090 conf 335 5 0.066 35 19.20 1.199 5.88% SYSTEM SENSOR sr strobe,wall mt 15 0.066 mens rr 6 0.090 19 19.09 1.312 6.43% SYSTEM SENSOR pc2r ceil h/s 15/75 0.090 hall 334 west end 7 0.143 26 18.95 1.451 7.11% SYSTEM SENSOR pc2rl ceil h/s 75 0.143 reception/waiting 8 0.218 49 18.73 1.669 8.18% SYSTEM SENSOR p2r wall h/s 115 0.218 open office 342 9 0.212 45 18.59 1.806 8.85% SYSTEM SENSOR p2r wall h/s 110 0.212 open office 350 10 0.176 48 18.51 1.887 9.25% SYSTEM SENSOR p2r wall h/s 75 0.176 training room 364 11 0.090 30 18.50 1.905 9.34% SYSTEM SENSOR p2r wall h/s 15/75 0.090 hall 355 END 0.000 0 18.50 1.905 9.34% END 0.000 0 18.50 1.905 9.34% END 0.000 0 18.50 1.905 9.34% END 0.000 0 18.50 1.905 9.34% END 0.000 18.50 1.905 9.34% END 0.000 18.50 1.905 9.34% END 0.000 18.50 1.905 9.34% END 0.000 18.50 1.905 9.34% END 0.000 18.50 1.905 9.34% END 0.000 18.50 1.905 9.34% _ HILLTOP 3RD FLOOR 7320 HUNZIGER 8/30/2017 Voltage Drop Calculations These calculations provide voltage drop calculations in three formats(Point to Point, End of Line,and Load Centering). End of line&load centering methods use only the wire gauge for the first device to source. Wire resistance is doubled for two wires(+&-). The voltage calculated @ the last device must not be lower then the manufactures listed minimum operating voltage. Point to Point End of Line Load Centering Project Name + - Circuit Within Limits Circuit Within Limits Circuit Within Limits Project Address d • . - Date e a , Area Covered End of Line Method Load Centering Method �,- ` .: � �Circuit# Nominal System Voltage -460446-101x- Totals Voltage Totals Voltage Minimum Device Voltage s Current Distance Drop Current Distance Drop Total Circuit Current °» Wire Ohm's 0.967 305 - 1.882 0.967 305 0.941 Gauge Per 1000 End of Line Voltage 18.518 End of Line Voltage 19.459 Distance from source to 1st device 9 "' Precent Drop 0.092 Precent Drop 0.046 Wire Gauge for balance of circuit Current in amps. Distance .117= 117 ma from Voltage Current Device Device Previous At Drop from Percent Candela at Rated Number Current Device Device Source Drop Device Manufacture Model# Rating Voltage Location Device 1 0.254 50 20.09 0.308 1.51% SYSTEM SENSOR pc2rl ceil h/s 177 0.254 open office 320 2 0.107 55 19.84 0.559 2.74% SYSTEM SENSOR p2r wall h/s 30 0.107 copy station 317 3 0.176 26 19.74 0.659 3.23% SYSTEM SENSOR p2r wall h/s 75 0.176 hall 310 4 0.107 50 19.60 0.796 3.90% SYSTEM SENSOR p2r wall h/s 30 0.107 hall 307 5 0.143 38 19.53 0.875 4.29% SYSTEM SENSOR pc2rl ceil h/s 75 0.143 break room 305 6 0.090 31 19.49 0.910 4.46% SYSTEM SENSOR p2r wall h/s 15/75 0.090 hall 303 7 0.090 55 19.46 0.942 4.62% SYSTEM SENSOR p2r wall h/s 15/75 0.090 hall 363 END 0.000 0 19.46 0.942 4.62% END 0.000 0 19.46 0.942 4.62% END 0.000 0 19.46 0.942 4.62% END 0.000 0 19.46 0.942 4.62% END 0.000 0 19.46 0.942 4.62% END 0.000 0 19.46 0.942 4.62% END 0.000 0 19.46 0.942 4.62% END 0.000 0 19.46 0.942 4.62% END 0.000 19.46 0.942 4.62% END 0.000 19.46 0.942 4.62% END 0.000 19.46 0.942 4.62% END 0.000 19.46 0.942 4.62% END 0.000 19.46 0.942 4.62% END 0.000 19.46 0.942 4.62% HILLTOP 3RD FLOOR 7320 HUNZIGER N1C2 8/30/2017 FIRE SYSTEM ACCESSORY Model 5495 tSILENT Distributed Power Module ivj KNIGHT In an emergency, by Honeywell you need maximum power The 5495 Distributed Power Module by Silent Knight is the most powerful and cost-effective power supply available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensore,Gentex®,AMSECO®, Wheelock and Faraday—what you need to drive power- hungry components like ADA notification appliances.The 5495's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies.And,ADA retrofits are easier and less expensive with the 5495 because it integrates into current systems without the costly investment in new components. For the most sophisticated and cost-effective notification power supply available, you need the 5495. Call Silent Knight today for more information at 1-800-328-0103. Model 5495 accessories like magnetic door Distributed Power Module holders • Built-in synchronization for The 5495 is a 6 amp notification power appliances from System expander that provides its own AC Sensor®,Gentex®,AMSECO®, power connection, battery charging Wheelock and Faraday circuit,and backup battery for use with fire and security controls such as the • Stand alone operation Silent Knight Model 5208 Fire Control • Lightweight design adds to ease of /Communicator.The 5495 is the cost- installation and reduces shipping effective solution for powering costs notification appliances required by the • Operates with most polarized, UL Americans with Disabilities Act(ADA). Listed notification devices The 5495 has built-in ANSI cadence pattern,which can upgrade older • ANSI Cadence pattern output control panels that lack cadence capability built-in capability. Connection to Local Fire Control Features The 5495 may be connected to a local • UL Listed for 6 amps of notification fire control which utilizes Class A or Class B type notification circuits Model 5495 power operating between 9 and 32 VDC.The Distributed Power Module • Power supply's advanced switch control panel's notification circuit is mode design reduces damaging connected to one of the inputs on the Approvals heat and manages power up to 50% 5495.The control panel's notification • UL Listed more efficiently than other systems circuit end-of-line resistor is also • • Dip switches allow for easy connected across two terminals on the MEA 429-92-E Vol XII reconfiguration 5495,which provides supervision • CSFM 7300-0559:123 • 24 VDC filtered output voltage between the 5495 and the fire control • NFPA 72 • Four power-limited notification panel. Polarized audible and/or visual • OSHPD(CA)OSP-0065-10 outputs;2 Class A or 4 Class B,or 1 notification devices are then connected (see accessories) Class A and 2 Class B to the 5495 signal circuits using the • Additional continuous auxiliary 4.7k52 end-of-line resistors provided. output Since the 5495 draws very little power from the control, it is possible to • 3 amps per output circuit connect one 5495 to each notification • 2 inputs;2 Class B or 2 Class A circuit on the control panel and still • Ground fault detector/indicator provide full supervision of the • Independent trouble relay notification circuits all the way back to • AC loss delay option shuts off power the control panel. PN 350395 Rev G to non-essential high-current ©2015 Honeywell International Inc. FIRE SYSTEM ACCESSORY Model 5495 Distributed Power Module Model 5495 Block Diagram Signal Circuit Output Signal 1 Signal 1 Input Distributed Signal 2 Signal Circuit Output Signal 2 Power Input Module 5495 Signal 3 (Optional) Signal 4 120 VAC Aux. Power Trouble Output Local Fire Control (Alternative to notification circuit trouble.) Supervision •4 Class B(Style Y) Aux trouble: Yellow The 5495 supervises a variety of (1 Class A&2 Class B) Output troubles(1-4): Yellow functions including: Amps per output circuit:3.0(6.0 amps • Low AC power total) Ordering Information • Low battery condition Notification circuit output: 5495 Distributed Power Module • Earth ground fault Alarm Current(for typical voltages) Accessories: • Auxiliary output power limit condition drawn from main panel's notification • EOL supervision trouble or power appliance circuits. SK-SCK Seismic Compliance Kit limited condition at an output 12 VDC 6.5 mA When a trouble condition occurs,the 24 VDC One input circuit- 15 mA; 5495 creates a trouble condition on the Both input circuits-30 mA host control signal circuits to which it is No.of inputs: 2 connected.the 5495 still maintains the ability to be activated by the host Input configuration:2 Class B or 2 control. In addition,the 5495 provides a Class A Form C trouble relay output as an Input voltage range: 9-32 VDC alternative to using the notification Battery charging capacity: 35.0 AH circuit trouble. Ambient temp.: 32°to 120° F Electrical Specification (0°to 49°C) AC input: 120 VAC at 2 amps Mechanical Output:24 VDC at 6 amps Dimensions: Current: 12.25"W x 16"H x 3"D(30.88 cm W x Standby 75 mA 40.64 cm H x 7.62 D cm) Alarm 205 mA Auxiliary power circuit: 1 Indicator Lights Notification circuits:4 AC power on : Green Output configuration: Battery trouble: Yellow •2 Class A(Style Z) Ground fault: Yellow SILENT This document is not intended to be used for installation purposes.We try to KNIGHT keep 000n decnco specificur applicationsprductinformatior anticipateup-to-all ate requirements.and accuratAll.speciWefiancationsot are all 11/ subject to change without notice.For more information,contact Silent Knight by Honeywell 12 Clintonville Road,Northford,CT 06472-7161 Phone:(800)328-0103, Fax:(203)484-7118.For Technical Support,please call 800-446-6444. Assembled In America www.silentknight.com r S IIJ - iffig`/QS ' S ° ES *Th, SYSTEM `... SENSOR' F I Indoor Selectable- E Output Horns, Strobes, and Horn Strobes for 144.4 Wall Applications SpectrAlerl®Advance audible visible notification products SPECI Iett are rich with features guaranteed to cut installation timesAmilikaimiladuaRE `_r c�r� and maximize profits. Features The SpectrAlert Advance series offers the most versatile and • Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry. With white and red plastic housings,wall and ceiling mounting • Tamper-resistant construction options,and plain and FIRE-printed devices,SpectrAlert Advance • Automatic selection of 12-or 24-volt operation at can meet virtually any application requirement. 15 and 15/75 candela • Field-selectable candela settings on wall units: 15,15/75, Like the entire SpectrAlert Advance product line,wall-mount horns, 30,75,95,110,115,135,150,177,and 185 strobes,and horn strobes include a variety of features that increase their application versatility while simplifying installation.All devices • Horn rated at 88+dBA at 16 volts feature plug-in designs with minimal intrusion into the back box, • Rotary switch for horn tone and three volume selections making installations fast and foolproof while virtually eliminating • Universal mounting plate for wall units costly and time-consuming ground faults. • Mounting plate shorting spring checks wiring continuity before To further simplify installation and protect devices from construction device installation damage,SpectrAlert Advance utilizes a universal mounting plate • Electrically Compatible with legacy SpectrAlert devices with an onboard shorting spring,so installers can test wiring • Compatible with MDL3 sync module continuity before the device is installed. • Listed for ceiling or wall mounting Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with three volume selections. Agency Listings (121 MEA LISTED A® approved 77125-125 165183388:188(4"sstrobes,t,5es) (torn 54011(clones.horn strobes.horns) chose str ) 555,2(strobes) 7135-1653180(horns,chanes) • SpectrAlert Advance Specifications Architect/Engineer Specifications General SpectrAlert Advance horns,strobes,and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch octagon back box,or double-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•Circuit'"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15,15/75,30,75,95, 110,115,135,150,177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.On four-wire products,the strobe shall be powered independently of the sounder.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Rangel 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 2.5"D(142 mm L x 119mm W x 64 mm D) Horn Dimensions 5.61L x 4.7"W x 1.3"D(142 mm L x 119mm W x 33 mm D) Wall-Mount Trim Ring Dimensions(sold as a 5 pack)(TR-HS) 5.7"L x 4.8"W x 0.35"D(145 mm L x 122 mm W x 9 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-temporal High 57 56 69 75 95 NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15175 30 75 ` 95 110 115 Temporal High 137 147 79 90 107 176,,.1 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Tones and Sound Output Data Horn and Horn Strobe Output(dBA) 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 75 75 80 80 86 86 96 96 3 Temporal Low 71 71 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 73 74 81 81 88 84 96 92 7r Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 74 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobes. SpectrAlert Advance Dimensions 4.7" 2.5=—• 71-4 '. 5.6" Mg its Wall-mount horn strobes SpectrAlert Advance Ordering Information Model Description Model Description Wall Horn Strobes Wall Strobes(cont.) P2R 2-Wire Horn Strobe,Standard cd,Red SRH Strobe,High cd,Red P2R-P 2-Wire Horn Strobe,Standard cd,Red,Plain SRH-P Strobe,High cd,Red,Plain P2R-SP 2-Wire Horn Strobe,Standard cd,Red,"FUEGO" SRH-SP Strobe,High cd,Red,"FUEGO" P2RH 2-Wire Horn Strobe,High cd,Red SW Strobe,Standard cd,White P2RH-P 2-Wire Horn Strobe,High cd,Red,Plain SW-P Strobe,Standard cd,White,Plain P2W 2-Wire Horn Strobe,Standard cd,White SWH Strobe,High cd,White P2W-P 2-Wire Horn Strobe,Standard cd,White,Plain SWH-P Strobe,High cd,White,Plain P2WH 2-Wire Horn Strobe,High cd,White Horns P2WH-P 2-Wire Horn Strobe,High cd,White,Plain HR Horn,Red P4R 4-Wire Horn Strobe,Standard cd,Red HW Horn,White P4R-P 4-Wire Horn Strobe,Standard cd,Red,Plain Accessories P4RH 4-Wire Horn Strobe,High cd,Red TR-HS Trim Ring,Wall,Red P4W 4-Wire Horn Strobe,Standard cd,White SBBR Indoor Surface Mount Back Box,Red Wall Strobes SBBW Indoor Surface Mount Back Box,White SR Strobe,Standard cd,Red SR-P Strobe,Standard cd,Red,Plain SR-SP Strobe,Standard cd,Red,"FUEGO" Notes: All-P models have a plain housing(no"FIRE"marking on cover) All-SP models have"FUEGO`marking on cover "Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings. "High cd"refers to strobes that include 135,150,177,and 185 candela settings. t� SYSTEM 3825 Ohio Avenue•St.Charles,IL 60174 WO/4 SystemS w�e Phone:800-SENSOR2•Fax:630-377-6495 Product e�arrs b changewPhu8 notice.SENSOR' www.systemsensor.com kr current product sfam O"B the latest at this data sheet. • SM'aEs SYSTEM SENSOR' I Indoor Selectable- : . Output Strobes and Horn Strobes forft Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut '4-4c,f0 las installation times and maximize profits with lower current draw and modern aesthetics. Features The System Sensor 1.-Series offers the most versatile and • Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry with lower current draws and modern aesthetics.With white and red • Tamper-resistant construction plastic housings,wall and ceiling mounting options,System Sensor • Automatic selection of 12-or 24-volt operation L-Series can meet virtually any application requirement. at 15 and 30 candela • Field-selectable candela settings on ceiling units: The entire L-Series product line of ceiling-mount strobes and horn 15,30,75,95,115,150,and 177 strobes include a variety of features that increase their application versatility while simplifying installation.All devices feature a plug-in • Horn rated at 88+dBA at 16 volts design with minimal intrusion into the back box,making installations • Rotary switch for horn tone and two volume selections fast and foolproof while virtually eliminating costly and time- • Universal mounting plate for ceiling units consuming ground faults. • Mounting plate shorting spring feature checks wiring continuity To further simplify installation,the L-Series utilizes a universal before device installation mounting plate so installers can mount them to a wide array of back • Electrically Compatible with legacy SpectrAlert and SpectrAlert boxes.With an onboard shorting spring,installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range of • Listed for ceiling mounting only application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING ® 411> D .PpR f:(1).1 USTE 85512 FM approved except 7125-16530504 S4011 for ALERT models 7135-16530503 3057383 • • • L-Series Specifications Architect/Engineer Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 1' -inch back box,4-inch octagon back box,or double- gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuir Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95,115,150,and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4 11/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Rangel 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range(MDL3) 8.5 to 17.5V(12 V nominal)or 16.5 to 33 V(24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8°diameter x 2.5°high(173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9°diameter x 3.4'high(175 mm diameter x 86 mm high) (SBBCRL,SBBCWL) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 30 cd. Avoca UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts Candela DC DC FWR 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15ed 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1K Temporal High 111 164 69 94 147 163 184 229 257 3.1K Temporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cdd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.1K Temporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Horn and Horn Strobe Output(dBA) 8-17.5 16-33 Volts Volts Switch Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 ` AV0S86800 L-Series Dimensions 2.47 1.37 = = 06.92 -� 2.50 06.83 ----, €€ Co")- IN:: 1 11, i I 7.-. I -IN 0 80008 __--- „ ..,-, ,/ Y Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box cm t' � x' \\ / fio. 01 1 +� a ., 1,,,,,,,iiri . . ,,g. e - 'N11111101141„. ...---..64191, . . - 4,-t1W:797:11Pf VII itikli . . . 0 „ Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box L-Series Ordering Information Model Description Model Description Ceiling Horn Strobes Ceiling Strobes PC2RL 2-Wire,Horn Strobe,Red SCRL Strobe,Red PC2WL 2-Wire,Horn Strobe,White SCWL Strobe,White SCWL-CLR-ALERT Strobe,White,ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box,Red SBBCWL Ceiling Surface Mount Back Box,White T SYSTEM 17System Sensor ``�`j ` 3825 Ohio Avenue•St.Charles,IL 60174 Proanaspedc ma e.alnaa .Mat s atom �jY SENSOR' Phone:800-SENSOR2•Fax:630-377-6495 '° � P'°� "�` °"•'8` " d ` na1:1688e01 6 a3m