Loading...
Report (73) fig VO/?'.a)/2-2 1I ttica AUG 8 2017 Worldwide - Fire Protection www.tyco-fire.com ��-�� ��; �-•��� �� Contacts Products BUILDING DIVISION N( Series TY-FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General NOTICE The TYCO Series TY-FRB Sprinklers Description described herein must be installed and , ` ° maintained in compliance with this doc- The TYCO Series TY-FRB,5.6 K-factor, ument, as well as with the applicable r„ Upright (TY313) and Pendent(TY323) standards of the National Fire Protec- Sprinklers described in this data sheet tion Association,in addition to the stan- ` , are quick response,standard coverage, dards of any other authorities having decorative 3 mm glass bulb-type spray jurisdiction. Failure to do so may impair ,, sprinklers designed for use in light p 9 g the performance of these devices. or ordinary hazard,commercial occupan- cies such as banks, hotels, and shop- The owner is responsible for maintain- :' ping malls. T. their fire protection system and devices in proper operating condition. The recessed version of the Series TY- The installing contractor or sprinkler FRB Pendent Sprinkler,where applica- manufacturer should be contacted with ! - ble, is intended for use in areas with a any questions. /` `; finished ceiling.This recessed pendent sprinkler uses one of the following: • A two-piece Style 15 Recessed Sprinkler s Escutcheon with recessed adjust- i/ ° . ham ment up to 5/8 inch (15,9 mm) from Identification /�. v% / the flush pendent position. %` Number (SIN) • A two-piece Style 20 Recessed s. Escutcheon with recessed adjust- TY313 Upright 5.6K, 1/2"NPT ment up to 1/2 inch (12,7 mm) from TY323 Pendent 5.6K, 1/2"NPT r;iii',-; - the flush pendent position. v," "`" The adjustment provided by the Technical Recessed Escutcheon reduces the Temperature Rating accuracy to which the fixed pipe drops Data 135°F(57°C) to the sprinklers must be cut. 155°F(68°C) Intermediate level versions of Series Approvals 200°F (7900°F (79°C) TY-FRB Sprinklers are described in UL and C-UL Listed 286°F(141 C) Technical Data Sheet TFP357. Sprin- FM, LPCB,and VdS Approved ° ( ° ) kler guards and shields are described CE Certified Finishes in Technical Data Sheet TFP780. Sprinklers with Polyester Finish are UL Sprinkler: Refer to Table A and C-UL Listed as Corrosion-Resis- Recessed Escutcheon:White Coated, tant Sprinklers. Chrome Plated,or Brass Plated Maximum Working Pressure Physical Characteristics 175 psi (12.1 bar) Frame Bronze 250 psi(17.2 bar)* Button Brass/Copper *The maximum working pressure of 250 psi Sealing Assembly Stainless IMPORTANT (17.2 bar)only applies to the listing by Un- Steel w/TEFLON Always refer to Technical Data derwriters Laboratories, Inc.(UL). Bulb Glass Sheet TFP700 for the "INSTALLER Discharge Coefficient Compression Screw Bronze WARNING"that provides cautions K=5.6 GPM/psi"2(80,6 LPM/barl!2) Deflector Bronze with respect to handling and instal- lation of sprinkler systems and com- .., ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 FEBRUARY 2014 TFP172 TFP172 Page 2 of 4 - Components: *Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16"(11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON Piiiiiinili-V-- .:`, /rrrrN \ ; 5 =I 7/16" rR (11,1 mm) ort } ��1 c 4 NOMINAL 2" I) (I I� MAKE-IN I (50,8 mm) IMEMP 2 Fr ii ya 2' \�� (I/ 1-3/8" 3 �, (50,8 mm) (34,9 mm) �_� WRENCH 1 1 / FLATS 1/2"NPT** DEFLECTOR* 1 . 2-7/8"(73,0 mm)DIA. - CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT(TY313)AND PENDENT(TY323)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE L. Operation Installation WRENCH RECESS The glass bulb contains a fluid which The TYCO Series TY-FRB,5.6 K-factor, .„,.....07.. expands when exposed to heat.When Upright(TY313) and Pendent (TY323) (USE ONLY the rated temperature is reached, the Sprinklers must be installed in accor- END"A") fluid expands sufficiently to shatter the dance with this section. glass bulb, allowing the sprinkler to activate and water to flow. General Instructions FIGURE 2 Do not install any bulb-type sprinkler if W-TYPE 6 the bulb is cracked or there is a loss SPRINKLER WRENCH Design of liquid from the bulb.With the sprin- kler held horizontally, a small air bub- Criteria ble should be present. The diameter WRENCH of the air bubble is approximately 1/16 RECESS The TYCO Series TY-FRB,5.6 K-factor, inch(1,6 mm)for the 135°F(57°C)and Upright (TY313) and Pendent(TY323) 3/32 inch(2,4 mm)for the 286°F(141°C) ��� Sprinklers are intended for fire protec- temperature ratings. / tion systems designed in accordance with the standard installation rules rec A leak tight 1/2 inch NPT sprinkler joint ognized by the applicable Listing or should be obtained by applying a min 11 Approval agency(such as, UL Listing mum to maximum torque of 7 to 14 2,0H �' s based on the requirements of NFPA ft.-lbs. (9,5 to 19,0 Nm). Higher levels 114...., 13, and FM Approval is based on the of torque can distort the sprinkler Inlet PUSH WRENCH requirements of FM's Loss Prevention with consequent leakage or impairment Data Sheets).Only the Style 15 or Style of the sprinkler. INTO ENSURE 20 Recessed Escutcheon is to be used Do not attempt to compensate for ENGAGEMENT for recessed pendent installations. insufficient adjustment in the Escutch- WITH SPRINKLER WRENCHING AREA eon Plate by under-or over-tightening FIGURE 3 the sprinkler. Re-adjust the position of the sprinkler fitting to suit. W-TYPE 7 RECESSED SPRINKLER WRENCH Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1.Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. TFP172 Page 3 of 4 Step 3. Tighten the sprinkler into the 2-7/8" DIA. sprinkler fitting using only the W-Type (73,0 mm) 6 Sprinkler Wrench(Figure 2).With ref- ` erence to Figure 1, apply the W-Type 6 2-1/4" DIA. Sprinkler Wrench to the wrench flats. FACE OF (57,2 mm) Torque sprinklers 7 to 14 ft.-lbs.(9,5 to SPRINKLER 19,0 Nm). FITTING 5/8"(15,9 mm) Recessed Pendent Sprinklers l' \ _� ; FLUSH The Series TY-FRB Recessed Pendent 3/8±5/16" Sprinklers must be installed in accor- (9,5±7,9 mm) ANI N '% j + ' dance with the following instructions. Step A.After installing the Style 15 or MOUN�ING ,�, 1/8" i Style 20 Mounting Plate over the sprin- SURFACE (3,2 mm) kler threads, and with pipe-thread j sealant applied to the pipe threads, CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) hand-tighten the sprinkler into the TY-FRB PLATE 3/4"(19,1 mm) sprinkler fitting. FIGURE 4 Step B.Tighten the sprinkler into the SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) sprinkler fitting using only the W-Type WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 7 Recessed Sprinkler Wrench (Figure RECESSED ESCUTCHEON 3).With reference to Figure 1,apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque - 2-7/8" DIA. _ sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 (73,0 mm) Nm). FACE OF Step C.After ceiling installation and fin- SPRINKLER 251/4" 21I Dm ishing,slide on the Style 15 or Style 20 FITTING ( ) Closure over the Series TY-FRB Sprin- 5/16±1/4" kler and push the Closure over the (7,9±6,4 mm) 1/2"(12,7 mm) Mounting Plate until its flange comes in + - FLUSH contact with the ceiling. } =-1 I ikiCare and � 1/8" J MOUNTING , Maintenance SURFACE (3, 3 2 mm) _. The TYCO Series TY-FRB,5.6 K-factor, I - Upright (TY313) and Pendent(TY323) CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) Sprinklers must be maintained and ser- TY-FRB PLATE 7/8"(22,2 mm) viced in accordance with this section. FIGURE 5 Before closing a fire protection system SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) main control valve for maintenance WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 work on the fire protection system RECESSED ESCUTCHEON that it controls, obtain permission to shut down the affected fire protection Modified sprinklers must be replaced. standards of any other authorities hav- systems from the proper authorities Sprinklers that have been exposed to ing jurisdiction. Contact the installing and notify all personnel who may be corrosive products of combustion, but contractor or sprinkler manufacturer affected by this action. have not operated,should be replaced regarding any questions. Absence of the outer piece of an if they cannot be completely cleaned Automatic sprinkler systems are rec- escutcheon, which is used to cover by wiping the sprinkler with a cloth or ommended to be inspected, tested, a clearance hole, can delay sprinkler by brushing it with a soft bristle brush. and maintained by a qualified Inspec- operation in a fire situation. Care must be exercised to avoid dam- tion Service in accordance with local The owner must assure that the sprin- age to the sprinklers before,during,and requirements and/or national codes. klers are not used for hanging any after installation. Sprinklers damaged objects and that the sprinklers are only by dropping, striking, wrench twist/ cleaned by means of gently dusting slippage,or the like, must be replaced. with a feather duster; otherwise, non- Also, replace any sprinkler that has a operation in the event of a fire or inad- cracked bulb or that has lost liquid from vertent operation may result. its bulb.(Ref.Installation Section.) Sprinklers which are found to be leak The owner is responsible for the ing or exhibiting visible signs of corro- inspection,testing,and maintenance of sion must be replaced. their fire protection system and devices in compliance with this document, as Automatic sprinklers must never be well as with the applicable standards painted, plated, coated, or other- of the National Fire Protection Associa- wise altered after leaving the factory. tion (e.g., NFPA 25), in addition to the TFP172 Page 4 of 4 P/N* 77 - XXX - X - XXX SPRINKLER TEMPERATURE FINISH RATINGS SIN 1 NATURAL BRASS 135 135°F(57°C) 370 5.6K UPRIGHT(1/2-NPT) TY313 3 PURE WHITE(RAL9010)°° 155 155°F(68°C) POLYESTER 371 5.6K PENDENT(1/2-NPT) TY323 q SIGNAL WHITE(RAL9003) 175 175°F(79°C) POLYESTER Use suffix"I"for ISO 7-1 connection; 9 CHROME PLATED 200 200°F(93°C) for example,77-370-4-175-I Eastern Hemisphere sales only 286 286°F(141°C) TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Ordering Warranty Procedure For warranty terms and conditions,visit Contact your local distributor for avail- www.tyco-fire.com. ability.When placing an order, indicate the full product name and Part Num- ber(P/N). Sprinkler Assemblies with NPT Thread Connections Specify:Series TY-FRB Upright or Pen- dent(specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify)tem . perature rating, (specify) finish, P/N (specify,refer to Table A). Recessed Escutcheon Specify:Style 15 Recessed Escutcheon with (specify')finish, P/N(specify') Specify: Style 20 Recessed Escutch- eon with(specify*)finish, P/N(specify') *Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 Copyright©2014 Tyco Fire Products,LP. All rights reserved. vice TEFLON is trademark of The DuPont Corporation. Fire Protection Products MALLEABLE IRON & CAST IRON FITTI 3I '« ))A!W!!= Malleable Iron Face Bushing AUG 8 2017 CITY OF TIGARD FIGURE 385 BUILD100140NisInr,t Size Face Bushing Black GaIv. NPS ON" NPS ,.' ON k kg Eb ktt3 3/a 10 0.08 0.04 - - /a 20 1/2 15 0.06 0.03 0.06 0.03 1---.% /z 15 0.16 0.07 0.16 0.07 1 25 3/a 20 0.10 0.05 0.10 0.05 1/2 15 0.30 0.14 11/4 32 3/a 20 0.27 0.12 - - 1 25 0.19 0.09 0.19 0.09 1/2 15 0.40 0.18 - - 11/z 40 3/a 20 0.39 0.18 - - 1 25 0.33 0.15 - - 11/4 32 0.16 0.07 0.16 0.07 1 25 0.65 0.29 0.65 0.29 2 50 11/4 32 0.53 0.24 0.53 0.24 11/z 40 0.40 0.18 0.40 0.18 21/2 65 11/4 32 1.10 0.50 - - 2 50 0.40 0.18 0.40 0.18 3 80 21/2 65 0.99 0.45 - - Note:See following page for malleable iron pressure-temperature ratings. Cast Iron Face Bushing FIGURE 385 Unit Weight Size Face Bushing Black NPS ON NPS " • ON lbs `kg 3 80 2 50 13.30 6.03 ` 21/2 65 2.55 1.16 4 100 3 80 19.20 8.71 According to specifications,hex bushings and cored plugs should be used with 150#malleable iron and 125#cast iron.Solid plugs and face bushings are recommended for use with 250#and 300#fittings. Note:See page 3 for cast iron pressure-temperature ratings. PROJECT INFORMATION APPROVAL STAMP Project: ❑Approved Address: Approved as noted Contractor: ❑Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: PF-11.16 4 MALLEABLE IRON FITTINGS (0)4 M' ' 7 iii k I , a ' n,,,:,k,±. „.,. ..... Malleable Iron Threaded Pipe Unions Malleable Iron Threaded Fittings Pressure- Temperature Ratings Pressure-Temperature Ratings Pressure Pressure Temperature Class 150 Class 250 Class 300Class 300 Temperature ,.,_,41)>-•'' (°C)0 psi...,,_ bar psi bar- psi .' bar Class 150 Sizes 1/4"-1" Sizes 11/4"-2" Sizes 21/4"-3° 20° 28 9° (6-25 mm) (32-51 mm) (64-76 mm) to to 300 20.7 500 34.5 600 41.4 (°F) '' (C) psi..:, bar psi bar psi bar psi bar`;: 150° 65.6° -20° -28.9° 200° 93.3° 265 18.3 455 31.4 550 379 to to 300 20.7 2,000 137.9 1,500 103.4 1,000 68.9 150° 65.6° 250° 121.1° 225 15.5 405 27.9 505 34.8 200° 93.3 265 18.3 1,785 123.1 1,350 93.1 910 62.7 300° 148.9° 185 12.8 360 24.8 460 31.7 250° 121.1 225 15.5 1,575 108.6 1,200 82.7 825 56.9 350° 176.7° 150 10.3 315 21.7 415 28.6 - 300° 148.9 185 12.8 1,360 93.8 1,050 72.4 735 50.7 400° 204.4° 110 7.6 270 18.6 370 25.5 450° 232.2° 75 5.2 225 15.5 325 22.4 350° 176.7 150 10.3 1,150 79.3 900 62.1 650 44.8 500° 260.0° - - 180 12.4 280 19.3 400° 204.4 - - 935 64.5 750 51.7 560 38.6 450° 232.2 - - 725 50.0 600 41.4 475 32.8 550° 287.8° - - 130 9.0 230 15.9 Note:Unions with Copper or Copper Alloy seats are not intended for use where temperature exceeds 500° 260.0 - - 510 35.2 450 31.0 385 26.5 450°F 550° 287.8 - - 300 20.7 300 20.7 300 20.7 c us OV Anvil Class 150/300 Malleable Iron Fittings conform to ASME APPROVED 816.3 and Unions conform to ASME 316.39. For Listings/Approval Details and Limitations,visit our website at ALL ELBOWS&TEES 3/8"(10 DN)and LARGER ARE 100%GAS TESTED AT www.anvilintl.com or contact an Anvil Sales Representative. A MINIMUM OF 100 PSI.(6.9 bar) Standards and Specifications Dimensions Material Galvanizing* Thread Pressure Rating ;. ,UALLEAB`Is'llt©N TTINGS, r, Class 150/PN 20 ASME B16.3 ASTM A-197 ASTM A-153 ASME B1 20.1 ASME 816.3 Class 300/PN 50 ASME 816.3 ASTM A-197 ASTM A-153 ASME B1 20.1 ,ty ASME B16.3 : �:.'. MALLEABLE IRN A ONIONS :. s. �'. 4.. - Class 150/PN 20 ASME B16.39 ASTM A-197 ASTM A-153 ASME B1 20.1 ASME B16.39 Class 250 ASME B16.39 ASTM A-197 ASTM A-153 ASME B1 20.1 ASME B16.39 Class 300/PN 50 ASME 816.39 ASTM A-197 ASTM A-153 ASME B1 20.1 ASME 816.39 `ASTM B 633,Type I,SC 4,may be supplied as alternate zinc coating per applicable ASME B16 product standard. PF-11.16 4 CAST IRON FITTINGS (0)Anw! . ,,.,#. ,,,,,oVI::;€;t:••,"' :'-‘',','":t.::::.-;01‘g,;,,,),; / Fa e 4 :i•t Vi I 4.."''''//' //j` , � rye ,v .,.wS eR +t� _.M�} P \ 4 y '' ax � � • r is � + ‘1,,, / \ 'r ••• Anvil standard and extra heavy cast iron threaded fittings Cast Iron Threaded Fittings are manufactured in accordance with ASME 616.4.Plugs and Temperature Class 125 Pressure- Temperature Ratings Class 250 bushings are manufactured in accordance with ASME B16.14. Pressure NOTE:Figure 367 Concentric Reducers do not meet the overall length requirement of ASME B16.4. All other dimensions are in compliance. °�� � Gtr psi bar -20°to 150° -28.9 to 65 6 175 12.1 400 27.6 200° 93.3 165 11.4 370 25.5 C � US APPROVED ® 250° 121.1 150 10.3 340 23.4 300° 148.9 140 9.7 310 21.4 176.7 125 8.6 300 20.7 For Listings/Approval Details and Limitations,visit our website at 350° www.anvilintl.com or contact an Anvil Sales Representative. 400° 204.4 — — 250 17.2 Standards and Specifications Dimensions Material Galvanizing* Thread Pressure Rating ,ft'''gST,IRON THREADED JI NG ;: y k., Dimensions Class 125 ASME B16.4 ASTM A-126(A) ASTM A-153 ASME B1.20.1 ASME B16.4 Class 250 ASME B16.4 ASTM A-126(As) ASTM A-153 ASME B1 20.1 ASME 616.4 CAST IRON D UGS A�D BUSHINGS y s ASME 616.14 ASTM A-126(A) ASTM A 153 ASME B1.20.1 ASME B16.14 ASTM B 633.Type I,SC 4,may be supplied as alternate zinc coating per applicable ASME 616 product standard. PF-11.16 MALLEABLE IRON & CAST IRON FITTINGSnw! General Assembly of Threaded Fittings 1) Inspect both male and female components prior to assembly. • Threads should be free from mechanical damage,dirt,chips and excess cutting oil. • Clean or replace components as necessary. 2) Application of thread sealant • Use a thread sealant that is fast drying,sets-up to a semi hard condition and is vibration resistant.Alternately,an anaerobic sealant may be utilized. • Thoroughly mix the thread sealant prior to application. • Apply a thick even coat to the male threads only.Best application is achieved with a brush stiff enough to force sealant down to the root of the threads. 3) Joint Makeup • For sizes up to and including 2"pipe,wrench tight makeup is considered three full turns past handtight.Handtight engagement for 1/2"through 2"thread varies from 41/2 turns to 5 turns. • For 21/2"through 4"sizes,wrench tight makeup is considered two full turns past handtight. Handtight engagement for 21/2" through 4"thread varies from 51/2 turns to 63/4turns. PF-6.13 • RECAVEr MECHANICAL TEE (THREAD) AUG 8 ?017 Model 402 AR CO CITY OF IIGARD erNCE * BUILDING' .SIV SION • c <: L US The Model 402 Mechanical Tee provides a fast and easy mid-pipe threaded branch outlet. It elimi- �� LISTED nates the need for welding or mulple fittings. The ;� ,; mechanical tee utilizes ductile iron housings, a < grade E moulded gasket and heat-treated carbon APPROVED steel track bolts and nuts. Pressure rated to 300 , psi (20 bar). • Pipe Material • Carbon steel, Schedule 10, Schedule 40. For use with alternative materials and wall thicknesses please contact ARGCO. Maximum Working Pressure • Up to 300 psi/20 bar Function •Joins carbon steel pipe. • Provides a rigid pipe joint designed to restrict axial or angular movement. CERTIFICATIONS/LISTINGS Underwriters Laboratories, Underwriters Laboratories Canada, Factory Mutual. SPECIFICATIONS - MATERIAL Housing Sections: Ductile Iron conforming to ASTM A 536, Grade 65-45-12. Housing Coating: Standard: Orange Enamel Available: Hot Dipped Galvanized Gasket: Standard: Grade E EPDM (Type A) ARGCO's products are listed by Underwriters Laboratories UL Canada and Approved by Factory Mutual for we and dry (oil free air) sprinkler services within the rated working pressure. Bolts and Nuts Standard: Carbon Steel oval neck track bolts meeing ASTM A449 and ISO 898-1. Carbon steel hex nuts meet ASTM A563 Grade B. Nuts and Bolts are zinc electroplated per ASTM B633 NZ/FE5, finish Type III. Available: Stainless Steel. Meets ASTM F593, Group 2 (316 stainless steel), condition CW. Hex nuts meets ASTM F594, Group 2 (316 stainless steel), condition CW, with galling-resistant coating. System No. Location Spec Section Paragraph Submitted By Date Approved Date ARGCO.com ARGCO Updated 5/10/2017 ©ARGCO ARGGO.eom aoo-a�,� MECHANICAL TEE (THREAD] °r Model 402 AR CO SINCE©3891 m al Aft/� 4illi 1'i 'ISI: / �" am Nalw AM i �, r', C Dimensions-in/mm Hole Dia.T Item# Nominal Size Pipe +3.2,-0 Bolt Size Bolt Torque in/mm O.D. /+0.13,-0 Tt A B C D in/mm Ft-Lbs/(Nm) 7010302 2 x 3/4 2.375 x 1.05 1.50 1.97 2.20 1.65 4.72 2.99 3/8 x 2-3/8 45-50 50 x 20 60.3 x 26.7 38 50 56 42 120 76 M 10 x 60 (61-68) 7010303 2-1/2x3/4 2.875 x 1.05 1.50 2.02 2.42 1.85 5.63 2.99 1/2x2-5/8 45-50 65 x 20 73 x 26.7 38 56 61.5 47 143 76 M 12 x 65 (61-68) 7010304 2 x 1 2.375 x 1.327 1.50 1.85 2.20 1.65 4.72 2.99 3/8 x 2-3/8 45-50 50 x 25 60.3 x 33.7 38 47 56 42 120 76 M 10 x 60 (61-68) 7010305 2 x 1-1/4 2.375 x 1.669 1.75 2.05 2.68 1.65 4.72 3.31 3/8 x 2-3/8 45-50 50 x 32 60.3 x 42.4 44.5 52 68 42 120 84 M 10 x 60 (61-68) 7010306 2 x 1-1/2 2.375 x 1.9 1.75 2.05 2.80 1.65 4.72 3.37 3/8 x 2-3/8 45-50 50 x 40 60.3 x 48.3 44.5 52 71 42 120 84 M 10 x 60 (61-68) 7010307 2-1/2 x 1 2.875 x 1.327 1.50 2.09 4.42 1.85 5.63 2.99 1/2x2-5/8 50-70 65 x 25 73.0 x 33.7 38 53 61.5 47 143 76 M 12 x 65 (68-95) 7010308 2-1/2x1-1/4 2.875 x 1.669 1.75 2.28 2.89 1.85 5.63 3.31 1/2x2-5/8 50-70 65 x 32 73.0 x 42.4 44.5 58 73.5 47 143 84 M 12 x 65 (68-95) • 7010309 2-1/2x1-1/2 2.875 x 1.9 2.00 2.28 2.89 1.85 5.63 3.54 1/2x2-5/8 50-70 65 x 40 73.0 x 48.3 50.8 58 73.5 47 143 90 M 12 x 65 (68-95) 7010310 7010310A 7010310B 7010311 3 x 1 3.5 x 1.327 1.50 2.40 2.74 2.17 6.22 2.99 1/2 x 2-5/8 50-70 80 x 25 88.9 x 33.7 38 61 69.5 55 158 76 M 12 x 65 (68-95) 7010312 3 x 1-1/4 3.5 x 1.669 1.75 2.56 3.19 2.17 6.22 3.31 1/2x2-5/8 50-70 80 x 32 88.9 x 42.4 44.5 65 81 55 158 84 M 12 x 65 (68-95) 7010313 3 x 1-1/2 3.5 x 1.9 2.00 2.80 3.19 2.17 6.22 3.54 1/2x2-5/8 50-70 80 x 40 88.9 x 48.3 50.8 71 81 55 158 90 M 12 x 65 (68-95) 7010314 3 x 2 3.5 x 2.375 2.50 2.76 3.19 2.17 6.22 3.98 1/2x2-5/8 50-70 80 x 50 88.9 x 60.3 63.5 70 81 55 158 101 M 12 x 65 (68-95) 7010315 7010316 4 x 1 4.250 x 1.327 1.50 2.87 2.99 2.44 6.57 2.99 1/2 x 2-5/8 50-70 100 x 25 108.1 x 33.7 38 73 76 62 167 76 M 12 x 65 (68-95) 7010317 4 x 1-1/4 4.25 x 1.669 1.81 3.07 2.99 2.44 6.57 3.27 1/2 x 2-5/8 50-70 100 x 32 108.0 x 42.4 46 78 76 62 167 83 M 12 x 65 (68-95) 7010318 4 x 1-12 4.25 x 1.9 2.09 3.27 2.99 2.44 6.57 3.54 1/2x2-5/8 50-70 100 x 40 108.0 x 48.3 53 83 76 62 167 90 M 12 x 65 (68-95) 7010319 4 x 2 4.25 x 2.375 2.50 3.27 3.07 2.44 6.57 3.94 1/2x2-5/8 50-70 100 x 50 108.0 x 60.3 63.5 83 78 62 167 100 M 12 x 65 (68-95) 7010320 4 x 2-1/2 4.25 x 3 2.76 2.87 4.13 2.44 6.57 4.61 1/2x2-5/8 50-70 100 x 65 108.0 x 76.1 70 73 105 62 167 117 M 12 x 65 (68-95) Nuts must be torqued to 50 ft/lbss (68 N/m). Do not exceed 70 ft/bls (90N/m) of torque. Increased bot torque will not improve sealing and may cause product failure. ARGCO.com ARGCO Updated 5/10/2017 ©ARGCO AGCCIco„ BOO-a6-1016 MECHANICAL TEE (THREAD] 1 ,/' Model 402 AR ` CO - SINCE O 1981 Bolt Torque: For Metal Pipe: illk The nuts must be torqued to AV Oh oli 50ft-lbs/68N-M with even gaps ' % I' ' between the bolt pads. ' B11 II �'s ,SAM DO NOT exceed 70ft-lbs/95N-M of -,� torque on the nuts. D • C Dimensions-in/mm Hole Dia.T Bolt Torque Item# Nominal Size Pipe +3.2,-0 Bolt Size Ft-Lbs/ in/mm O.D. /+0.13,-0 Tt A B C D in/mm (Nm) 7010321 4 x 3 4.5 x 3.5 3.50 3.31 3.94 2.56 7.13 5.35 112x2-3/4 50-70 100 x 80 114.3 x 88.9 89 84 100 65 181 136 M 12 x 70 (68-95) 7010322 5 x 1 5.250 x 1.327 1.50 3.35 3.50 2.91 8.07 2.99 1/2 x 3 50-70 125 x 25 133.0 x 33.7 38 85 89 74 205 76 M 12 x 75 (68-95) 7010323 5 x 1-1/4 5.25 x 1.669 1.81 3.54 3.50 2.91 8.07 3.27 1/2 x 3 50-70 125 x 32 133.0 x 42.4 46 90 89 74 205 83 M 12 x 75 (68-95) 7010324 5 x 1-1/2 5.25 x 1.9 2.09 3.74 3.50 2.91 8.07 3.54 1/2 x 3 50-70 125 x 40 133.0 x 48.3 53 95 89 74 205 90 M 12 x 75 (68-95) 7010325 5 x 2 5.25 x 2.375 2.52 3.74 3.50 2.91 8.07 3.94 1/2 x 3 50-70 125 x 50 133.0 x 60.3 64 95 89 74 205 100 M 12 x 75 (68-95) 7010326 5x 2-1/2 5.25 x 3 3.15 3.82 3.62 2.91 8.07 4.61 1/2 x 3 50-70 125 x 65 133.0 x 76.1 80 97 92 74 205 117 M 12 x 75 (68-95) 7010327 5 x 3 5.25 x 3.5 3.62 4.17 3.70 2.91 8.07 5.08 1/2 x 3 50-70 125 x 80 133.0 x 88.9 92 106 94 74 205 129 M 12 x 75 (68-95) 7010328 6 x 1 6.250 x 1.327 1.50 4.45 4.00 3.58 9.17 2.99 1/2 x 3 50-70 150 x 25 159 x 33.7 38 113 101.5 91 233 76 M 14 x 75 (68-95) 7010329 6 x 1-1/4 6.250 x 1.669 1.81 4.45 4.00 3.58 9.17 3.27 1/2 x 3 50-70 150 x 32 159.0 x 42.4 46 113 101.5 91 233 83 M 12 x 75 (68-95) 7010330 6 x 1-1/2 6.250 x 1.9 2.09 4.41 4.00 3.58 9.17 3.54 1/2 x 3 50-70 150 x 40 159.0 x 48.3 53 112 101.5 91 233 90 M 12 x 75 (68-95) 7010331 6 x 2 6.250 x 2.375 2.52 4.37 4.00 3.58 9.17 3.94 1/2 x 3 50-70 150 x 50 159.0 x 60.3 64 111 101.5 91 233 100 M 12 x 75 (68-95) 7010332 6 x 2-1/2 6.250 x 3 3.15 4.37 4.15 3.58 9.17 4.61 5/8x3-1/3 85-90 150x65 159.0x76.1 80 111 105.5 91 233 117 M 16x85 (115-122) 7010333 6 x 3 6.250 x 3.5 3.62 4.33 4.15 3.58 9.17 5.08 5/8 x 3-1/3 85-90 150 x 80 159.0 x 88.9 92 110 105.5 91 233 129 M 16 x 85 (115-122) 7010334 8 x 1 8.625 x 1.327 1.50 5.98 5.35 1.92 12.68 2.99 5/8 x 3-1/2 85-90 200 x 25 219.1 x 33.7 38 152 136 125 322 76 M 20 x 90 (115-122) 7010335 8 x 1-1/4 8.625 x 1.669 1.75 5.98 5.79 1.92 12.68 3.31 5/8x3-1/2 85-90 200 x 32 219.9 x 42.4 44.5 152 147 125 322 84 M 20 x 90 (115-122) 7010336 8 x 1-1/2 8.625 x 1.9 2.00 5.98 5.79 1.92 12.68 3.54 5/8x3-1/2 85-90 200 x 40 219.1 x 48.3 50.8 152 147 125 322 90 M 20 x 90 (115-122) 7010337 8 x 2 8.625 x 2.375 2.50 5.43 5.79 1.92 12.68 3.98 5/8 x 3-1/2 85-90 200 x 50 219.1 x 60.3 63.5 138 147 125 322 101 M 20 x 90 (115-122) 7010338 8 x 2-1/2 8.625 x 3 2.76 5.08 6.14 1.92 12.68 4.61 5/8x3-1/2 85-90 200 x 65 219.1 x 76.1 70 129 156 125 322 117 M 20 x 90 (115-122) 7010339 8 x 3 8.625 x 3.5 3.50 5.31 6.24 1.92 12.68 136 5/8 x 3-1/2 85-90 200 x 80 219.1 x 88.9 89 135 158.5 125 322 5.35 M 20 x 90 (115-122) Nuts must be torqued to 50 ft/lbss (68 N/m). Do not exceed 70 ft/bls (90N/m) of torque. Increased bolt torque will not improve sealing and may cause product failure. ARGCO.com ARGCO Updated 5/10/2017 ©ARGCO • , moi, FM Approvals' Pipe Fittings These fittings are suitable for interconnecting piping,valves and other components in both wet and dry automatic sprinkler systems. Installation should be according to applicable sprinkler system fabrication rules.These rules limit the minimum size of sprinkler piping to 1 in., nominal. FM Approved pipe fittings of smaller sizes are intended for use as valve trim,gauge connections,and for other peripheral service.The water flow path of the sprinkler system cannot be designed using smaller sizes than 1 in.,nominal. Unless otherwise noted in the listing,these fittings have 175 psi(1205 kPa)rated working pressure. Threaded connections on fittings can be made to FM Approved threadable thinwall pipe or to Schedule 40 pipe. Refer to the"Steel Pipe"listings for a summary of the various types of FM Approved steel pipe suitable for threading or grooving." The fittings manufacturer's installation instructions must be observed in all cases.When connections are made to FM Approved pipe, the pipe manufacturer's installation instructions must also be followed. Unless otherwise stated below,the maximum ambient temperature to which these fittings should be subjected is 225°F(107°C). Fittings, Side Outlet, Rigid These fittings allow installation of a perpendicular branch line of reduced size,while joining inline pipes of equal diameters.These fittings bolt over a hole in the run pipe,and allow installation of a perpendicular branch line of reduced size. The maximum branch line size is one pipe size reduced from the run pipe size. 402, 403, 501, 503 Product Fitting Nominal Pipe Size, Max Working Pressure, Remarks Designation Description mm psi(kPa) 12x1-1/4 1 1/2 2-1/2x1-1/4, 1-1/2 I 76 mm x 1-1/4, 1-1/2 o 3x1-1/4, 1-1/2,2 l£ r 4 x 1-1/4, 1-1/2,2,2-1/2,76 mm 300 a,b,c,d 5 x 1-1/2,2,2-1/2 (2070) Mechanical Tee 165 mm x 2,76 mm i 402 Grooved Outlet 6 x 1-1/4, 1-1/2,2,2-1/2,76 mm I 18x2,2-1/2, 76mm,3 00 139.7 mm x 1-1/2,2 2-1l2 3 0) w �G a,d 4 x 3,., 232 a,b,c,d /111-' , 16x3 4 (1600) o. 2 x 1/2,3/4, 1, 1-1/4, 1 1/2 1 1 2-1/2 x 1/2,3/4, 1, 1-1/4, 1-1/2 76 mm x 1/2,3/4, 1, 1-1/4, 1-1/2 3 x 1/2,3/4, 1, 1-1/4, 1-1/2,21 / g 108mmx1, 1-1/4, 1-1/2,2 403 Mechanical Tee 4 x 1, 1-1/4, 1-1/2,2,2-1/2 300 0) •a,b,c,d ,Threaded Outlet 5 x 1, 1-1/4, 1-1/2,2,2-1/2 • 41 •133mmx1, 1-1/4, 1-1/2,2 o 140 mm x 1, 1-1/4, 1-1/2,2 • 6 x 1, 1-1/4, 1-1/2,2,2-1/2 165 mm x 1, 1-1/4, 1-1/2,2,2-1/2 3 8 x 1 1-1/4, 1-1/2 2 2-1/2,3 l r,u>... umoawn ii,d.,,,. .x iiiiv..n� F...::.. „_ :av:: n�ro.._ „4„:„.„.____,iiiioiiiiiig 3 3 11-- ra- g i Mechanical Tee U Bolt :21;i:11xl.C/1421/12x;1,111-13://224-11:,31744: 300;501a,b,c,d $ 1 Threaded Outlet s 2-1/2 x 1/2,3/4, 1 ,(2070) 1$76 mm x 1/2,3/4, 1 r 3x1 31-1/4 x 1/2,3/4, 1 1 1-1/2 x 1/2,3/4, 1 Mechanical Tee 300 1502 Threaded Outlet 12 x 1/2,3/4, 1 0(2070) 1a, b,c,d 0 o .2-1/2 x 1/2,3/4, 1 y 176 1mm x 1/2 3/4 1 o ©2007-2017 FM Approvals.All rights reserved. 1 of 2 1 Remarks: a.For use with Schedule 10 and heavier pipe. b.For use with Chinese Standard GB/T 3091 pipe. c. For use with Chinese Standard GB/T 3092 pipe. d.For use with EPDM gasket. Company Name: Allied Rubber&Gasket Company(ARGCO) Company Address: 5816 Dryden Place,Suite 101,Carlsbad, California 92008,USA Company Website: http://argco.com New/Updated Product Listing: No Listing Country: United States of America Certification Type: FM Approved 500, 502,601,603* ©2007-2017 FM Approvals.All rights reserved. 2 of 2 Eddyth read 40 AUG 8 2017 A Lightweight Schedule 40 Replacement Pipe CITY t4 That Has a Corrosion Resistance Ratio of 1. ;UILUING ` 11;iRi t„ Bull Moose Tube Company has been making pipe for a long time and is recognized as a producer of quality pipe products. Eddythread 40 is designed with the same thoroughness as our other fine pipe products and now our customers have an option to buy a carefully designed replacement for Schedule 40 that: • Has a Corrosion Resistance Ratio of 1.0 • Has a Pressure Rating of 300 psi • Is Lighter Weight Than Schedule 40 • Is Approved by Factory Mutual and Listed by Underwriters Laboratories • Is Produced in Accordance to ASTM A-135 and A-795 • Can be Used With Standard Schedule 40 Threaded Fittings, Couplings and Valves • Is Produced From Steel With Excellent Properties of Strength and Threadability • Can be Used in Wet, Dry, Preaction, and Deluge Type Sprinkler Systems* • Offers Lower Freight Costs EDDYTHREAD 40 SPECIFICATIONS 1 1.461 1.083 70 1 1/4 2.070 1.418 51 1 1/2 2.547 1.654 44 2 3.308 2.123 30 CORROSION RESISTANCE RATIOS NOMINAL,...,:Pil'E SIZE(i): Fes,SCHEDULE40 iy '-EDDYTHFIEAD 40 1 1.00 1.00 1 1/4 1.00 1.00 1 1/2 1.00 1.00 2 1.00 1.00 *Eddythread 40 can be hot dipped galvanized to meet FM's requirement for dry systems """""'"."?`" ',.., m.. »m � + - \\ ,. .��; dna,. ...,\\�`R�\: ... :: ... 7/%i7i/;'r'•"",? 1819 Clarkson Road For additional information, 4( 1 Chesterfield,MO 63017 contact your salesperson today at C US `_ BULL.MOOSE TUBE COMPANY (800)325-4467 (800)325-4467 or(636)537-2600 USTED FAX:(636)537-2645 in the USA,or from Canada www.bullmoosetube.com call(800)882-4666 411:> A C A R O company e-mail:sales(aibullmoosetube.com APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 8/08