Loading...
Permit (65) CITY OF TIGARD BUILDING PERMIT 111 ` > COMMUNITY DEVELOPMENT Permit#: BUP2017-00188 f t GARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 08/17/2017 Parcel: 1S136CD02200 Jurisdiction: Tigard Site address: 7850 SW DARTMOUTH ST Project: Costco Subdivision: PALMER ACRES Lot: 3 Project Description: Demolition and reconstruction of the deli prep,chicken rotisserie,and meat prep rooms. Contractor: KEY MECHANICAL CO OF WASHINGTON Owner: COSTCO WHOLESALE CORPORATION 19430 68TH AVE SO PROPERTY TAX DEPT 111 KENT,WA 98032 999 LAKE DR ISSAQUAH,WA 98027 PHONE: 503-231-0731 PHONE: FAX: 503-236-5848 Specifics: FEES Description Date Amount Type of Use: COM Class of Work: ALT Type of Const: Permit Fee-Additions,Alterations, 08/17/2017 $4,947.15 Demolition Occupancy Grp: M Occupancy Load: 12%State Surcharge-Building 08/17/2017 $593.66 Dwelling Units: Plan Review 07/03/2017 $3,215.65 Stories: Height: ft DC Provision Review,COM TI-Ping 08/17/2017 $357.00 Bedrooms: Bathrooms: Plan Review-Fire Life Safety 08/17/2017 $1,978.86 Value: $780,000 Info Process/Archiving-Lg$2.00(over 08/17/2017 $30.00 11x17) Info Process/Archiving-Sm$0.50(up to 08/17/2017 $27.50 Floor Areas: 11x17) Metro Const.Excise Tax 08/17/2017 $936.00 Total Area: Accessory Struct: Basement: Carport: Covered Porch: Deck: Garage: Mezzanine: Total $12,085.82 Required: Required Items and Reports(Conditions) Fire Sprinkler: Yes Parapet: Fire Alarm: Yes Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if •k is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. ' ose rules are set forth in OAR 952-0 - 010 throu•'OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.19: o .800.332.2344. *sued By: • , i ,, r Permittee Signature: Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. rwrriiii=iiiMEM11=1=1=11== 11=t.. Building Permit Application Commercial FOR OFFICE USE ONLY City of Tigard Received Date/By: �L (7 , PermitNo.: 9 .10,1 q 13125 SW Hall Blvd.,Tigard,OR 97223i set) �' 1/2 O/7 CO/t Plan Revie Phone: 503.718.2439 Fax: 503.598.19 Date/By: 1' r3-.) OtherPermit:41 O/?_ )`L T Ii,A RI) Inspection Line: 503.639.4175 4 Date ReadyB y: e / Jur s: ® See Page 2 for !J Internet: www.tigard-or.gov t Q 1�t Notfied/Method: 7(16(/7 �. I Supplemental Information JUS r , TYPE OF•''''el.'-'''''''''''''''''''''''''c'''' ,. ' . ❑ D •1 , , .; .. . REQUIRED I AT 1-ANi)2 FAIGI LX I)i LLIN ❑ New construction �yny%i kkG Permit fees*are based on the value of the work performed. �1 Indicate the value(rounded to the nearest dollar)of all ® Addition/alteration/replacement ❑ Other: equipment,materials,labor,overhead,and the profit for the r CATEGORY OF CONSTRUCTION workindicated on this application. � d• ❑ 1-and 2-family dwelling ® Commercial/industrial Valuation: $ ❑ Accessory building IDMulti-familyNumber of bedrooms: ❑ Master builder ElOther: Number of bathrooms: JOB SITE INFORMATIO1K AND LOCATION Total number of floors: Job site address:7850 SW Dartmouth St New dwelling area: square feet City/State/ZIP:Tigard,OR,97223 Garage/carport area: square feet Suite/bldg./apt.no.:N/A Project name:Costco Food Prep.Area Covered porch area: square feet Cross street/directions to job site:Pacific Highway and Dartmouth Street Deck area: square feet Other structure area: square feet REQUIREDDATA C31►IMERCI,JUS CHECKL ST: Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.:1S136CD02200 Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the yDESCRIPTIOI pF WOQt work indicated on this application. Demolition and reconstruction of the deli prep,chicken rotisserie,and the meat prep rooms Valuation: $780,000.00 Existing building area: 145,824 square feet New building area: 145,824 square feet ,.. . .. m,s..•<,..;'71- ,.,. .,, ,:W:! f,,.0 lTt0a1 4Veg Number of stories: 1 Name:Costco Wholesale Corporation Type of construction: V-B Address:999 Lake Drive Occupancy groups: City/State/ZIP:Issaquah,WA 98027 Existing: Mercantile Phone:(425)313-8100 Fax ( ) New: Mercantile rfi rq x+ .....t, to r ; ro RKt . fi '�� wr J : gtaN.; t � 'f , :z' fif� . _,t .� ,CrTI: r k RC E ,rru mfER» � sof� �refewfescr • ,Business name:MG2 Structural plan review fee(or deposit): Contact name:Ken Wong FLS plan review fee(if applicable): Address:1101 Second Ave,Suite 100 City/State/ZIP:Seattle,WA 98101 Total fees due upon application: Phone:(206)962-6646 Fax::( ) Amount received: mrowir&v,,s`4 fik frxFtW4rfr i to,"i' %r1%u ., 1 LAR �. E-mail:ken.wong@mg2.com 4u " ,., "'-A ,�. . . . . <.,? .a U.,., ,, pl fit 01`,4' tyk:'` `'1ZAW h ' &A r`,�te r, ,�04fi,: t fi,'r �fi , f 4 Commercial and residential prescriptive installation of e` er ' f eAf ' A 4 . ': }k } ' fi✓ ;Wigg, roof-top mounted Photo Voltaic Solar Panel System. Business name:Key Mechanical Submit two(2)sets of roof plan with connection details m and fire department access,along with the 2010 Oregon Address:19430 68 Ave S Solar Installation Specialty Code checklist. City/State/ZIP:Kent WA 98032 Permit fee(includes plan review and administrative fees): $180.00 Phone:(253)872-7392 Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lic.: ` 3L(� 1,?l/r , Total fee due upon application: $201.60 Authorized signature: , :)4vN.et.......„_C____,\L„,' This permit application expires if a permit is not obtainedithi within 180 days after it has been accepted as complete. Print name:Mostafa Ahanchi,Costco orized Agent Date:6 / /,//17 * Fee methodology set by Tri-County Building Industry �� Service Board. I:\Building\Permits\BUP-COM PermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) City of Tigard Ifi i'llhi . COMMUNITY DEVELOPMENT DEPARTMENT TICARD Building Permit Review — Commercial - No Land Use Building Permit #: / ,,,,,,...,,, , _,0, /, Site Address: ---2 >c 5 / c yl. S7- Suite/Bldg#: Project Name: ,(.a 3 fL6 (Name of commercial business occupying the space. If vacant,enter Spec Space.) Planning Review 1 Proposal: , / ),T/Chh , --74:'".)..0/--- Existing LExisting Business Activity: ps— aneteL.. fr,. .' J Proposed Business Activity: // /1 // / /A Verify site address/suite#exists and active in permit syst . ■, ! `ver Terrace Neighborhood: ❑ Yes No oning: �_ �� lC� ennitted Use: Yes ❑ No 0 Spec Space firm no land use required. BunZBusiness License• Exists: Yes 0 No,applicant notified to obtain business license Notes: Approved by Planning: _____ _._- . .%� i Date: C-/ Revisions (after Building Submittal only) Reviewer Date Revision 1: 0 Approved ❑ Not Approved Revision 2: 0 Approved 0 Not Approved Revision 3: ❑ Approved 0 Not Approved Building Permit Submittal Original Submittal Date: 4/)/7/ri 7 Site Plans: # 440- Building Plans: # 3 Building Permit#: r-E'fter building permit#above. Workflow Routing: Ea-i fanning 0 Permit Coordinator 0 Building Workflow Sign-off: [ --Si�gn-off for Planning(include notes from planning review) Route Application Documents: Efding: original permit application, site plans,building plans, engineer and beam calculations and trust details,if applicable,etc. Notes: By Permit Technician: % Date: 0/) I:\BuildingWorms\BldgPermitRvw COM_NoLandUse 060116.docx Permit Coordinator Review ❑ Conditions "Met"prior to issuance of building permit ❑ Approved,NOT Released: Date: Notes: Revisions (after Building Submittal only) Revision Notice 1: Date Sent to Applicant: Revision Notice 2: Date Sent to Applicant: Revision Notice 3: Date Sent to Applicant: Fees Entered: Wash Co Trans Dev Tax: El Yes U /A Tigard Trans SDC: Ci ►. N/A ?;ii §DC Parks SDC: ❑ Yes PI /A ?OK to Issue Permit Approved by Permit Coordinator: Date: //I/ I:\BuildineForms\BldgPernutRvw_COM_NoLandUse_070915.docx Commercial Application Checklist City of Tigard RECEIVED 13125 SW Hall Blvd.,Tigard,OR 97223 Phone:503.718.2439,Fax:503.598.1960 ('' " Internet address: www.tigard-or.gov JUN 2017 Cl . . • PROJECT INFORMATIO,`1 Project name:Costco Food Preparation Area- Deli/Chicken/Meat Alteration Date: Address: 7850 S.W. Dartmouth City: Tigard State: OR ZIP: 97223 Scope of work: demolition at re-construction of the deli prep.,chicken rotisserie,and the meat prep. rooms. Reference no.: Map and tax-lot no.: Contact person name: Ken Wong Company:MG2 P Y� Phone:(206) 962-6646 Fax: n/a Cellular phone: n/a E-mail: ken.wong@mg2.com NOTES AND INSTRUCTIONS • The purpose of this checklist is to help define a complete submittal package for the scope of work. Plan review will not take place until a complete package is submitted. • This checklist can be used for all commercial construction projects, including new construction, additions, alterations and tenant improvements. • For complex projects, applicants should use the "location" space to note the item's location and page number from the plans or the specification book. • It is not necessary to duplicate submittal information, even if it is asked for in multiple sections. • In the checklist, "Required"means that the applicant must provide this information for plan review. • In the checklist, "P"means— • if checked by the applicant—the information is provided for the plan review. • if checked by the plans reviewer—this information is required for the plan review. • In the checklist, "NA"means that the information does not apply. • Choose only those sections of the checklist that apply to your scope of work. Section 1.0, "General Project Data,"must be included with each project submitted. PRE-SUBMITTAL PROCESS An applicant may request a pre-submittal meeting with representatives of the jurisdiction in which the project will be built. The meeting may take place during the conceptual, schematic, or in-progress phase, or when the applicant has completed plans. INDEX OF CHECKLIST SECTIONS 1.0 General project data Page 2 7.0 Mechanical data (Types I and II 2.0 Civil data Page 2 kitchen-hood permits) Pae 6 3.0 Architectural data Page 3 8.0 Plumbingdata g 4.0 Structural data Page 7 Page 4 9.0 Electrical data Page 8 5.0 Mechanical data (new construction, tenant 10.0 Fire-suppression data Page 9 improvement, gas-piping permits) Page 5 11.0 Fire-detection and fire-alarm data Page 9 6.0 Mechanical data (additional or replacement 12.0 Re-roof installation data Page 10 rooftop-equipment installation permits) Page 6 13.0 Jurisdictional requirements Page 10 This checklist is for building department jurisdictions in Clackamas,Multnomah, and Washington counties. 440-2734(8/01/WEB/COM) I:\Building\Forms\COM-Checklist.doc 05/21/15 SECTION 1.0 — GENERAL PROJECT DATA Construction documents Location(sheet number or spec section) 1.1 ® Required No. of sets of plans: New: 3 TI: 3 TS-101 TS-101 -101 1.2 ® Required Cover sheet title block Ts-tot 1.3 ® Required Cover sheet vicinity map TS-101 1.4 ® Required Cover sheet plan index 1.5 0 P ❑ NA Code summary Ts1o1 1.6 ❑x P ❑ NA Deferred submittal summary Ts1o1 1.7 P ❑ NA Professional stamp and signature 1.8 ❑x P ❑ NA Fire and life-safety plan 1.9 ❑ P 0 NA Landscape plan 1.10 ❑ P x❑ NA Landscape specifications Supporting documents Notes 1.20 ❑ P ❑x NA Land-use or planning actions 1.21 0 P ❑ NA Required fire-flow calculations 1.22 ❑ P ® NA Fire-hydrant flow-test report 1.23 0 P ❑ NA Fire department or fire district building survey report 1.24 0 P ❑ NA Material safety data sheets (MSDS) SECTION 2.0 — CIVIL DATA Location(sheet number or spec section) Construction documents n101 2.1 ® Required Site plan TS1o1 2.2 ® Required Site utility plan rs1o1 2.3 ® Required Grading plan Ts1o1 2.4 ® Required Erosion-control plan 2.5 ❑ P 0 NA Utility-vault location and details Supporting documents Notes 2.20 ❑ P 0 NA Geotechnical/soil engineer report 2.21 ❑ P 0 NA Storm-water calculations 2.22 ❑ P 0 NA Site retaining-wall structural calculations 2.23 ❑ P 0 NA "Assurance of Compliance"with environmental rules .... 440-2734(8/01/WEB/COM) Tri-County Commercial Application Checklist 2 For use in building department jurisdictions in Clackamas,Multnomah, and Washington Counties I:\Building\Forms\COM-Checklist.doc SECTION 3.0 — ARCHITECTURAL DATA Construction documents Location(sheet number or spec section) 3.1 ® Required Floor plan(s) A101 3.2 ® Required Transverse and longitudinal cross sections Atot 3.3 ® Required OSSC Chapter 11 accessibility requirements Tsioi,MO1 &A201 3.4 ® P ❑ NA Interior elevations A201 3.5 ❑ P ❑x NA Exterior elevations 3.6 ❑ P ® NA Roof plans 3.7 ❑ P ❑ NA Exterior wall sections and details 3.8 ❑ P ❑x NA Reflected ceiling plan(s) 3.9 ❑ P © NA Fire-rated construction details 3.10 LI P NA Energy code compliant construction details and specifications 3.11 ❑ P ❑x NA Door schedule 3.12 ❑ P ❑x NA Glazing schedule 3.13 ® P ❑ NA Furniture plan ,2oi Supporting documents Notes 3.20 ❑ P ❑x NA Energy code compliance forms/calculations 3.21 ❑ P ❑x NA Material safety data sheets (MSDS) 3.22 ❑ P ❑x NA Hazardous materials inventory statement(HMIS) 3.23 ❑ P ❑x NA Hazardous materials management plan (HMMP) 3.24 ❑ P ❑x NA Written fire and life-safety evacuation plan for area of rescue assistance 3.25 ❑ P ❑x NA Active and passive smoke-control information 440-2734(8/01/WEB/COM) Tri-County Commercial Application Checklist 3 For use in building department jurisdictions in Clackamas, Multnomah, and Washington Counties i:\BuildingTorms\COM-Checklistdoc • SECTION 4.0 — STRUCTURAL DATA Construction documents Location(sheet number or spec section) 4.1 ® Required Structural cover sheet 4.2 ❑ P 11 NA Foundation plan 4.3 ❑ P ® NA Under-slab mechanical plan 4.4 ❑ P 0 NA Under-slab electrical plan 4.5 ❑ P x❑ NA Under-slab plumbing plan 4.6 0 P 0 NA Floor framing plan s1.1 4.7 ❑ P 1=1 NA Roof framing plan 4.8 0 P ❑ NA Structural elevations sl.l 4.9 ❑x P ❑ NA Structural details and cross sections st.t 4.10 ❑ P 0 NA Standpipe information 4.11 ❑x P ❑ NA Special inspector/structural observation matrix so.t Supporting documents Notes 4.20 ❑ P ❑x NA Geotechnical/soil engineer report 4.21 ❑ P 0 NA Site-specific seismic hazard report 4.22 ❑ P 0 NA Design narrative 4.23 ❑x P ❑ NA Structural calculations see Structural submittal 440-2734(8/01/WEB/COM) Tri-County Commercial Application Checklist 4 For use in building department jurisdictions in Clackamas, Multnomah, and Washington Counties I:\Building\Forms\COM-Checklist.doc SECTION 5.0 - MECHANICAL DATA (New construction, tenant improvement, gas piping permits) Construction documents Location(sheet number or spec section) 5.1 ® Required Floor plan M-1 5.2 ® Required Equipment schedule M-5 5.3 ❑ P ❑x NA Site plan 5.4 ❑ P ❑x NA Under-slab mechanical plan 5.5 ❑ P 0 NA Roof plan 5.6 P ❑ NA Fuel gas piping plan M-4 5.7 ❑ P ❑ NA HVAC equipment and duct plan(s) M-2 $t M-5 5.8 ❑ P ❑x NA Roof access details 5.9 ❑ P ® NA Duct smoke detector plans 5.10 ❑ P IN NA Fire/smoke damper locations 5.11 ❑ P I NA Smoke control plan 5.12 ❑ P ® NA Outside air (OSA) table 5.13 ❑x P ❑ NA Refrigeration equipment and piping plan R5.0 at R6.0 5.14 P ❑ NA Kitchen equipment plan 5.15 ❑x P ❑ NA Type I and/or Type II kitchen hood plan (see Section 7.0 Mechanical Data) 5.16 ❑ Px❑ NA Fume/vapor hood plan 5.17 ❑ P ❑x NA Process piping/product and/or exhaust-conveying duct plan 5.18 ❑ P ❑x NA Fire-rated construction details 5.19 ❑ Px❑ NA Equipment hanger/fastener details Supporting documents Notes 5.20 ® Required Structural calculations for vertical loads and lateral loads for equipment weighing over 400 pounds See Structural Submittal 5.21 P ❑ NA Equipment manufacturers' catalog"cut sheets" or specifications See CaptiveAire Manufacturer Submittal 5.22 ❑ P ❑x NA Outside air (OSA) calculations 5.23 ❑ P ❑x NA Smoke-control calculations 5.24 ❑ P ❑x NA Combustion air calculations 5.25 ❑x P ❑ NA Fuel gas piping sizing calculations M-1 5.26 ❑x P ❑ NA Make-up air calculations M-2 5.27 ❑ P ® NA Energy code compliance forms 5.28 ❑ P ❑x NA Boiler information 440-2734(8/01/WEB/COM) Tri-County Commercial Application Checklist 5 For use in building department jurisdictions in Clackamas,Multnomah, and Washington Counties i:\Building\Forms\COM-Checklist.doc X SECTION 6.0 — MECHANICAL DATA (Additional or replacement rooftop installation permits) Construction documents Location(sheet number or spec section) 6.1 0 Required Roof plan M-5 6.2 ❑ P ® NA Roof framing plan 6.3 ❑ P ❑ NA Fuel gas piping plan M-4 6.4 ❑ P 0 NA Roof access details Supporting documents Notes 6.20 ® Required Structural calculations for vertical loads and lateral loads for equipment weighing over 400 pounds See Structural Submittal 6.21 ❑ P ❑ NA Equipment manufacturers' catalog"cut sheets" or specifications See cut-sheets submittal 6.22 ® P ❑ NA Fuel gas piping sizing calculations 6.23 ❑ P x❑ NA Energy code compliance forms SECTION 7.0 — MECHANICAL DATA (Type I and Type II kitchen hood permits) Construction documents Location(sheet number or spec section) 7.1 ® Required Site plan TS1ol 7.2 ® Required Floor plan(s) M-1 7.3 0 Required Kitchen equipment plan M-2, M-3 at M-4 7.4 ® Required Kitchen equipment and hood elevations M-5 7.5 ❑ P © NA Roof plan 7.6 ® P ❑ NA Cross sections through hoods, ducts and shafts M-5 7.7 ❑ P 0 NA Fire-rated construction details 7.8 ❑ P © NA Fire suppression details Supporting documents Notes 7.20 ® Required Structural calculations for vertical loads and lateral loads for equipment weighing over 400 pounds See Structural Submittal 7.21 ® Required Make-up air calculations M-2 7.22 ❑ P ❑ NA Equipment manufacturers' catalog"cut sheets" or specifications See cut-sheets submittal 7.23 ❑ P ® NA Hood/grease extractor listing documentation 7.24 ❑ P 0 NA Hood/grease duct sizing calculations 7.25 ❑ P ❑ NA Fire suppression information See fire protection submittal 440-2734(8/01/WEB/COM) Tri-County Commercial Application Checklist 6 For use in building department jurisdictions in Clackamas,Multnomah, and Washington Counties I:\Building\Forms\COM-Checklist.doc SECTION 8.0—PLUMBING DATA Construction documents Location(sheet number or spec section) 8.1 ® Required Floor plan(s) M-t a M-3 8.2 ® Required Piping and material schedule M-3 8.3 ® Required Equipment layout plan M-3 8.4 ® Required Fixture schedule M-5 8.5 ❑ P 0 NA Site utility plan 8.6 ❑ P 0 NA Building cross section 8.7 ❑ P ❑x NA Rise diagram 8.8 ❑ P 0 NA Roof plan 8.9 ❑ P 0 NA Back flow prevention location 8.10 ❑ P ® NA Irrigation plan 8.11 ❑ P ® NA Fire-rated construction details 8.12 0 P ❑ NA Under-slab plumbing plan M-3 Supporting documents Notes 8.20 ® Required Structural calculations for vertical loads and lateral loads for equipment weighing over 400 pounds See Structural Submittal 8.21 ❑ P ❑ NA Equipment manufacturers' catalog"cut sheets" or specifications See cut-sheets submittal 8.22 ❑ P ® NA Utility maintenance agreements 8.23 ❑ P 0 NA Water supply calculations 8.24 ❑ P 0 NA Sanitary system calculations 8.25 ❑ P E NA Irrigation demand calculations 8.26 ❑ P 0 NA Roof drain and storm water calculations 440-2734(8/01/WEB/COM) Tri-County Commercial Application Checklist 7 For use in building department jurisdictions in Clackamas, Multnomah, and Washington Counties i:\Building\Forms\COM-Checklist.doc SECTION 9.0—ELECTRICAL DATA Construction documents Location(sheet number or spec section) 9.1 ® Required No. of sets of plans: 2 E-tat E-2 9.2 ® Required Floor plan(s) E-2 9.3 ® Required Electrical load calculations E-1 9.4 ® Required One line diagram E- 9.5 ® Required Feeder riser diagram E-1 9.6 ® Required Available fault current information E-1 9.7 ® Required Panel schedule(s) E-1 9.8 ❑ P © NA Site electrical plan 9.9 ❑ P © NA Fire-rated construction details 9.10 II P ❑ NA Lighting plan 9.11 ❑ P 1=1 NA Emergency power system and emergency lighting plan 9.12 ❑ P I NA Under-slab electrical plan Supporting documents Notes 9.20 ® Required Structural calculations for vertical loads and lateral loads for equipment weighing over 400 pounds See Structural Submittal 9.21 ❑ P IN NA Energy code compliance forms and calculations for lighting 9.22 LI P ® NA Emergency power system specifications 9.23 ❑ P El NA Feeder riser information 9.24 0 P ❑ NA Lighting equipment manufacturers' catalog "cut sheets" or specifications 440-2734(8/01/WEB/COM) Tri-County Commercial Application Checklist 8 For use in building department jurisdictions in Clackamas, Multnomah, and Washington Counties I:\Building\Forms\COM-Checklist.doc SECTION 10.0-FIRE SUPPRESSION DATA Construction documents Location(sheet number or spec section) 10.1 ® Required Floor plan(s) rs1o1 10.2 ® Required Sprinkler piping plan(s) FP2.0 10.3 El P x❑ NA Site plan 10.4 0 P ❑ NA Standpipe information FP1.0 10.5 El P 0 NA Back flow prevention information 10.6 ❑ P © NA Reflected ceiling plan(s) 10.7 ❑ P x❑ NA Transverse and longitudinal cross sections 10.8 ❑ P NA Fire-rated construction details 10.9 ❑ P x❑ NA Specialty fire suppression system plans and list of systems Supporting documents Notes 10.20 ® Required Structural calculations for vertical loads and lateral loads for equipment weighing over 400 pounds See Structural Submittal 10.21 ® Required Equipment manufacturers' catalog"cut sheets' See CaptiveAire Manufacturer Submittal 10.22 ❑ P ❑ NA Hydraulic calculations 10.23 ❑ P El NA Specialty fire suppression system information SECTION 11.0-FIRE DETECTION AND ALARM DATA Construction documents Location(sheet number or spec section) 11.1 ®Required Floor plan(s) FP1.0 11.2 ❑ P ® NA Site plan 11.3 ❑ P ❑x NA Reflected ceiling plan(s) 11.4 El P NA Transverse and longitudinal cross sections 11.5 El P ❑x NA Wiring schematic 11.6 El P 0 NA Elevator recall information 11.7 ❑ P ® NA Operational matrix 11.8 ❑ P 0 NA Fire-rated construction details 11.9 El P ❑x NA Standard electrical notes Supporting documents Notes 11.20 ® Required Structural calculations for vertical loads and lateral loads for equipment weighing over 400 pounds See Structural Submittal 11.21 ® Required Equipment manufacturers' catalog"cut sheets" See Captive/tire Manufacturer Submittal 11.22 ® Required Installer certification information n/a existing fire detection system 11.23 El P ❑ NA Battery calculations 11.24 El P El NA Sample fire alarm log book 11.25 ❑ P ❑ NA Emergency power system specifications 11.26 ❑ P ❑ NA Monitoring station information 11.27 El P ❑ NA Voltage drop calculations 440-2734(8/01/WEB/COM) Tri-County Commercial Application Checklist 9 For use in building department jurisdictions in Clackamas,Multnomah, and Washington Counties i:\Building\Forms\COM-Checklist.doc SECTION 12.0 — RE-ROOF INSTALLATION DATA Con tion documents Location(sheet number or spec se 12.1 ® ' • ' ed Site plan or building location map 12.2 ® Requires •ccupancy classification 12.3 ® Required Typ- onstruction 12.4 ® Required Minimum .. lass required 12.5 ® Required Class of roofing to s. 'I stalled 12.6 ® Required Roof plan 12.7 ❑ P ❑ NA Parapet and scupper cros ion s Supporting documents Notes 12.20 ® Required Pre-re- . inspection report 12.21 ® Required ' .ofing system listing information 12.22 ® Re• ' Roofing manufacturer's catalog"cut sheets" 12.23 ! ❑ NA Structural calculations . ❑ P ❑ NA Structural engineer's report SECTION 13.0 — JURISDICTIONAL– SPECIFIC REQUIREMENTS Construction documents Item Location(sheet number or spec section) 13.1 ❑ P ❑ NA [' Required 13.2 ❑ P ❑ NA ❑ Required 13.3 ❑ P ❑ NA ❑ Required 13.4 ❑ P ❑ NA ❑ Required 13.5 ❑ P ❑ NA ❑ Required 13.6 ❑ P ❑ NA ❑ Required 13.7 ❑ P ❑ NA ❑ Required 13.8 ❑ P ❑ NA ❑ Required 13.9 ❑ P ❑ NA ❑ Required 13.10 ❑ P ❑ NA ❑ Required 440-2734(8/01/WEB/COM) Tri-County Commercial Application Checklist 10 For use in building department jurisdictions in Clackamas,Multnomah, and Washington Counties I:\Building\Forms\COM-Checklist.doc CosTco RECEIVED JUN 2 8 2017 January 2017` CITY OF TIGARD 3UILDI NG DIVISION Re: Authorized Agent of Costco Wholesale To Whom It May Concern: This letter hereby authorizes Mostafa Ahanchi to act on behalf of the Construction Department of Costco Wholesale as Authorized Agent in regard to any Costco construction project in North America. He is authorized to sign all jurisdictional, service and utility related documents having to do with any Costco building or site under construction. Should you need any further information, please contact me at 425.313.8100. Sincerely, Ali Me.' :111r:: Sen; Vice President of Construction 999 Lake!hive * Issaquah, WA 98027 • 425/313-8100 • www.costco,com MG2 Corporation 1101 Second Ave,Ste 100 206 962 6500 Seattle,WA 98101 MG2.com RECEIVED TRANSMITTAL JUN 2 8 2017 Bul��ll�G DIVI I� To City of Tigard 13125 SW Hall Blvd Tigard, OR 97223 Attn Community Development Department Date 06.27.17 Phone 503.718.2439 Project Tigard Fax 503.598.1960 Project Number 95-1840-21 25 From Ken Wong, Jamie Elderkin Number Of Pages 50+ Incl. Cover Page Cc Todd Philabaum Send Via FedEx Priority Overnight - By 10:30am Re Costco Wholesale Tigard Food Prep Area a3 u_ }, N W > y > .. a 0� r, n > 0 dl O ce O A � E d O T Q7 T °' a ,2 E Q , Qty Description c $ 2 S 8 2 d 3 MG2 Permit Drawings (TS101, A101, A201, S0.1, S1.1, E-1, x E-2, M-1 thru M-5, FP1.0, FP2.0, FP2.1) 3 Custom Cooler Manufacturer Drawings (Sheet 1, Sheet 2) x 2 Custom Cooler Manufacturer Structural Load Calculations x 2 Hood Support Load Calculations x 1 CaptiveAire Manufacturer Exhaust Hood Cut Sheets x 1 Permit Fee - Check #107721 x 1 City of Tigard Permit application x 1 City of Tigard Commercial Application Checklist x Notes Please find the submittal for plan review attached for the alteration of the Food Preparation Area of Costco Wholesale. If you have any questions or require further information, please contact Jamie Elderkin (206.962.6808; Jamie.elderkin@mg2.com) or Ken Wong (206.962.6646; ken.wong@mg2.com). Additionally, we would appreciate it if you could email us a receipt for the enclosed check and permit/plan check number for our record and use in future communication. Thank you! Privileged and confidential information: the information in this document is intended only for the use of the above named recipient. Any wrongful review, dissemination, distribution or copying of this communication is strictly prohibited. If errors occur in transmission, or enclosures are not as noted, please notify us at once.