Plans (158) r Markup Legend SPRINKLER SYMBOL DEFINITION COLOR/LINETYPE LEGEND %BLUE LINES=FEED TO FIXTURES(BATH,SHOWER,ETC.). f 0 Delete Line // \ /'\ /\ XXX-XX GREEN LINES- INTERLEVEL CONNECTIONS/SUPPLY. J o MAXIMUM SPACING(TYP) BLACK LINES=SPRINKLER HEAD TO SPRINKLER HEAD. O a o Add Line — — SPRINKLER MODEL(TYP) - = 1/2"PIPE SIZE w o HEAD SYMBOL(TYP) / - =3/4"PIPE SIZE a�§u Add Tee I - = 1"PIPE SIZE 0 a u 1-1/4"PIPE SIZE ',1'!,:'1 w Add Elbow ..,..6,„.,,.,,,,.;,sOD * �aP�3 Add Coupling CITY OF TIGARD 5 <W tip RECEIVED Ciro I-w3 Add Head -�- ,����� Approved � �,( ',*.,,„-2 Conditionally Approved0z > ,,-2 Delete Head217-(X 1- [ ] z 0,%4 o J��k See Letter to: Follow [ ] JUL 5 2017 Q ,o�oz00%'ow Move Head -Q-• -o- Attached ['ermitNumber:ffIsTA017— 00/00 "�,-`�`-irCa ° Note:All revisions mus[be reviewed by Uponor n „ ,I' /� p G`l�rY� p�j�l" l y [ms`s p, F-_¢-f m o E U w c ¢c Table F002-1 Address:130 140 SW /'� tijS�Jtr T e.er BUILDING l�f�t"i'w.�9V o zc3 Multipurpose Fire Safety Systems 88. ,,-.,..E.,,,,,,2 s< r . The Uponor Residential Fire SafetySystem is a residential fire rotections j' A' 'tj� °i"-r • `� 26, ,......-.:,...E. z system installed in combination with the cold side of the domestic potable } ems]v'. I - Ig '04.01.0:i .-c .o f o Q�,o o>Q a z water system. Only licensed contractors trained by Uponor can install this y�' C j�'i� - o°z N> z¢ system. Jam" 7 ®C y . �. _._ v- � Q i¢ o zc z'<�>3z What to do if Changes are Required U zz����¢�d ¢dmo If any features or obstructions require the addition or deletion of sprinkler - E.,-L'7',`,615.,6 z°o `�m 1"AQTIONSUAPEX INTERLEVEL 1"AQUAPEX INTERLEVEL w mz ¢?x heads,or significant relocation of sprinkler heads,contact the Uponor Design CONNECTIONS FROM SECOND CONNECTIONS FROM FIRST O m "'d o E a a Z"m h y- FLOOR TO SECOND FLOOR -LL`s' z i 2,' >V F N Department to determine if observed changes require a redesign FLOOR TO THIRD FLOOR o (888.594.7726). _ --- r� SAFET` - z2Sz°o3 °zam o 888.594.7726 �-�— _-_ fi. I 1 _.... - - _ zQ Q� ' ,, '�z MOST HYDRAULICALLY REMOTE HEADS r �_ 1- // \\ A �z ,,,„,, .z. HEAD# GPM PRESSURE REQ'D AT STREET R" r 144. - 71 l� `Hii;A ' I °`'>�z'�O o i �. A V� \ _i-==® - . _ -. �f �� pcs'Lr r ��, III I- oo�mFaso9wyk�m 1 HEAD H.4 11 28.35 - 1 /'i u Ak <�o� 2 HEAD H.8&H.7 20.0023 35.79 L'I P L(28-186:T1881.1... i = + / > m z °,9' , ' ' 1,1/e l k' I H.10 H.9 / ( / IEI I 1st Floor .l V,._ 7 RC-RESLF-14 r KC=RELF-14 FURNACE� 7 2nd Floor 17+ 1 I / 8 3rd Floor - i� ( 7,.; I I 4':.-/‘ / i \ \ '\ I R, / \\ I L BE \ 16 TOTAL I- R( RESLF 14 / y�__C- LF,f 1 1\ \ A 1 \ t �. , Ear r rl, %� " I \V -t < CG� I here by certify that this plan,specification, �. j• � -- L-ff•- or report was prepared by me or under my SENJU Model RC-RESLF37 LowFlow K3.7 Residential Concealed Pendent SS8261 \ I,A - \ :RE 1�. I; Tandem 2-Car --�, direct supervision and that I am NICET h n _,1, _ \ I \ \\ III Garage a �r NI ( S.1 MAIN SHUTOFF Certified at Level IV. 0 ' ' 15 K=3.7, 162F°,7/16"Orifice,Maximum Spacing 14'x14' m SENJU Model RC-RESLFIT LowFlow K3.7 Residential Concealed Pendent SS8261 ,� I 1 F r, ., )S n. / , \\ 1 r / Tl P.--- _ VALVE LOCATION RC-RESLF-14 Sprinkler head demand: 10 gpm @ 7.3 a. a y 0 - - - a a• _ + r� . '. \\ L ., r 81 F Brentat : Kotula - " I) 1 I' 28±0 2 ti II Date: Reg.No.113889 1 K=3.7, 175F°,7/16"Orifice, Maximum Spacing 14'x14' s IrHiEe_8444E ALL n Lu 1 RC-RESLF-14-175 Sprinkler head demand: 11 gpm @ 8.8 !,,,,,,2.1.,7N-,. th N„,_-.1 `L \ \ _ ,r= N Af I, 1-1/4"AquaPEX TO I I1I _ ,,� L 1 \ 1� 6 M.25 / 1\ �_ RP FRC SYSTEM 7 SLF 14 / �_��r 1_:r` ech.-I 1 1 T:�$ i it,'-(1 1 R2 /i<.3 • y io - _ T \ - -Qi Gr— I \ r DOWN IT , a L (.i,.<,. 1 1'II \ FIDE „_r R'N -i IP ii- 1 I a \ • k I RI-RE LF=111A \ \ PER r f ''2 5,ri .E Irl RC F 1 ' , , �� X11 9 T 8� �� J A \ <,, T.3&, �I W v s R T2 ,L5 il.,„:: .e. 1 a „ w �n6(� H�0i ..._ 3 _ _ I moo IMI .. as L F Ili -7 1i I. 7 RC'-RES F=11 ° T.40 LI r `Jq ' 1 Q c H O 1, t12. H Gj 11T T •., 6 F.9 41 _ w = CURRENT STATIC ` Ett$ 3 r o o Ce R .Ri '-" RISER 8F PII1. a EXTERIOR WALL . a <a w T 34 �� PEE i_C /� WATER PRESSURE ELEV=109' 4 .33 Al)� M z w u < STATIC: 62psi r n i0 11 a (V o CCC/ 1 �1-t/a"AquaPEX I,a �'{3L,v`- rn U � 1 �\ 1t i�� t Ce N z o -.'"---„,.,,,,,,,,,,TO SYSTEM `' 1 .it��t`tt'v. 1 �� - 11� - �� >�t 2. ‘.._-_,JJ,.) 1' I I�(I Y I 1t- 0 TO HOT WATER HEATER 1 ! 7 RGRESLF 14 R I�IESI�F 14. -+2ear-1,,,,, 1I L-n SoHo n� > a m 1 ELEv-loa' RC-RE�SL1 I 11 T - , f�ES Z Y � -` 1` i t FLOOR 1--I 6<ft C C / �/ 1-/a"FULL PORT QnE2 m BALL VALVE { LL I. — L —�- F�p m e �24-6� a-o' �aY! 1 J / I — q T _ - H ((Q�� W w ,r-NT or �.1 nom I ac m m z; a 'm o 0 C1:1 I--1 G�Y552,V-'1 z3 a w � c'''2; ELEV=100 ELEV=100' / -- ��x g O' o 3 THIRD FLOOR 2 SECOND FLOOR FIRST FLOOR �UVV� ////////////J SHEET DESCRIPTION H 1"METER - -- 35'OF 100'OF F100 i _ 1 n F100,' n ALL LEVELS 1"COPPER-K 1-1/2"AquaPEX 1/4 — 11-0" 1/4 = 11_011 F100 i/^n = i 1_U 1 `t 1 P o ' 4 WATER SERVICE DETAIL 5 15 SHEET NUMBER r _100 - -- - NTSSi "' 1/4„=1,_0„ © UPONOR - CONFIDENTIAL F100 F- Markup Legend SPRINKLER SYMBOL DEFINITION COLOR/LINETYPE LEGEND %BLUE LINES= FEED FIXTURES(BATH,SHOWER,ETC.). o Delete Line 0 XXX-XX GREENLINES= INTERLEVEL CONNECTIONSjSUPPLY. i-• u I BLACK LINES=SPRINKLER HEAD TO SPRINKLER HEAD. Q o MAXIMUM SPACING(TYP) /. = 1/2"PIPE SIZE > o Add Line SPRINKLER MODEL(TYP) � � 3 4"PIPE SIZE C a,G° HEAD SYMBOL(TYP) �: _ / u Add Tee I 1 — — = 1"PIPE SIZE 0 N o u = 1-1/4"PIPE SIZE W 3 LL w o v �z Add Elbow >,`r�iza s. o3 Add Coupling Hy v C 3 A N ro 6 m Add Head 1 2 3 G L~W I i -�I�( zS o C�o o` Delete Head -lX)- o� zY-z >�5- �n ¢"az= c= "N ~f ,.'3 ¢`.c. .< '1.2-<7....., o ^7.. _ _ _ _ du o _oz¢o Move Head zNy¢ > yy i �a O O o7hz o �7-' la=xCmO Note:All revisions must be reviewed by Uponor ,. p�o?u 7 zo_C< -Ca ' oox- zg>7.Table FOO2-1o Multipurpose Fire SafetySystems CC C>QJr.`m C Y o�z¢m o QC_F, The Uponor Residential Fire Safety System is a residential fire protectionsft c ¢ o o z system installed in combination with the cold side of the domestic potable YJ m c c N>N¢a C z 3?o water system. Only licensed contractors trained by Uponor can install this o_z_6 F ¢w<>°; system. N 6,4,�z �i �37., zz. mow What to do if Changes are Required IJ d<=waw -<,`r¢ In z7.UCno S>O,CC If any features or obstructions require the addition or deletion of sprinkler �W-c-k,�o,,..2.-.<6"�h�u heads,or significant relocation of sprinkler heads,contact the Uponor Design C 7 , 1 -<r-z o z o z�"o 5 to determine if observed changes require a redesign ¢ ? -.,,,s,,,, -,2,5,- Department x (888.594.7726). 1 ��lzzd37.z7.z�co� R _ 'Zr,i mErd»'oCz¢ 1 es� r¢ z : I e - � aL6FvC'h r � ��� iii rig I" rao 0000- T1 r _ Rb-RESLF14 RC-RESLF-14 t. r' - WATER ?T R a; E� R h ROI-•' SIF-1 \RC-RESLF714 -LPII S r `rFn }._ II i,-�I FI I. II r c SILT D(,CR RE I here by certify that this plan,specification, v < or report was p prepared by me or under my 1 ( I " <r TFJ direct supervision and that I am NICET i I Certified at Level IV. < (I Tandem 2 Car o �. E� s vALVENLocAT LOCATION VI Garage I�I� Brent D Kotula Z.-',::. VT5i11-% d `tr I g TINIER ni -, IT j A5.'±-/ Date: Reg.No.113889 I� s;.0157,1 4 h J C /r J IR Di II T.24 1 T37 k PE RGRES�F 1 ,_ �4i ✓y M.25 I.L� '1'A"Aquage7CT0 I ,-,,,L_ 4 rkkh r Cr ' SYSTEM - � LO CE I o .N- �.�, /I' �- ` \ 1"AQUAPEX INTERLEVEL R P a J ®I L: I ���E 1 ill 11'"9• v It�d d F.3 F.2 / - Mech. EH Et INSULATE E., / '— -1-1.x,I� / v CONNECTIONS FROM FIRST` ^ - I rL00F e ,F. q- _ ` it:+1 ‘111I' r-„�� CONNECTIONS FROM SECOND F // - • - -OI+ ",I / �r FLOOR TO SECOND FLOOR \\ {'I'/ J Jh i I C ^- 0 I (J 4 1"AQUAPEX INTERLEVEL _ _ / m ip��I F.5 AC-RESLF-1 A f f o� . . S F -11=1-- - FLOOR TO THIRD FLOOR - I / r� . y / A�o s � _ T 27( 6,444 T �� 09 E�a� `. �I W E _ iy - .11 GELATION 1' 77 '^1� n =� oom Irij N IT ' IV :PIAce w I .' T ri: ; FT ;,,,,a, T.40 1 R I "' E� �I �; 2 �1 • �.v �' � . „ T 1, F9' W zo`sonno T.34 T13 � CO a�a��� v I1U/, \�' \.�-- E,°c ��` h _i !I'1: 3 \\j� ?i OH iI HN o0oa°szo PER 11RUSS 1 i - o _ 4 ,eF.-u1 Z (� _' _ �mi �1� E i-" n Ii l _ � �� `�1fi ,� no H a' RC-RESLF-14 ll z E. ESL �1r.--,. LF I" �i�# ;' (' 4 TATER, EAC C RES' EL _ �' ll o RCSRE8Lr• 4 f m ��E V - T �/ Z Y EI(OR a Y - II - 4 �I 6J III 'I' rb __ -- — "( I I..L. I_, Q SKF Zmto III - z .. 1 u , ( r — I' rte ' ��� � �R rcri,t F.a m in v1—CHI--, - - 7 -- F'r 1--I '.- m E fT DCD m - �, ( } rr � s 2-8'482, � z 1' 1 .?ir _o m w o iWALLFEE Imo " z, 1.��) 'ail 'H Z � � G3Uss¢ ag =w d o ' 3 THIRD FLOOR 2 SECOND FLOOR FIRST FLOOR SHEET DESCRIPTION z I- --- - --- -- - -- -- - - ALL LEVELS-MIRROR Fioi 1411 = 11_011 Flol 1411 = 11_011 Fioi 1411 = 11_011 SHEET NUMBER 5 _ 0 mim5 5 1/4"-1.-0" g © UPONOR - CONFIDENTIAL F101 H Senju RC-RES:Open Web Truss/TJI Construction Insulation Recommendations AquaSAFETM GENERAL NOTES: In areas subject to freezing,care should be taken in unheated attic spaces See General Notes 8.2.5.7 for Architectural N ProPEX LF Brass Fire to cover Uponor AquaPEX tubing completely with insulation. Insulation Feature Requirements Sprinkler Adapter Tee should follow theguidelines of the insulation manufacturer. See UponorN 1. THIS SYSTEM IS DESIGNED AS PER NFPA I3D 2016 EDITION AS A RESIDENTIAL MULTIPURPOSE SYSTEM ` z Blocking Maybe Fire Sprinkler Adapter Document"Uponor AquaSAFE Attic Insulation Guidlines"for attic SECTION 3.3.11.3. Required.If is - "" Posh-on Nut installation guidelines(Provided in Contractors Documents package or online > 2. UPONOR COMPANY RESERVES THE EXCLUSIVE RIGHTS TO ALL DETAILS AND DRAWINGS AS SHOWN ON Blocking is Used, ' ` 1%4"Min. at www.uponorpro.com). CD z THIS SHEET. THESE DETAILS AND DRAWINGS ARE PROPRIETARY INFORMATION OF UPONOR COMPANY AND Use The 2 Top 1%"Max. >;71'z Screw Holes. III���- z Planter Boz Window,Ba Window or Similar Feature. C oa UNAUTHORIZED USE MAY BE SUBJECT TO PROSECUTION TO THE FULL EXTENT OF THE LAW. I / 'Bottom of Mounting Extreme Temperature Installations Y _ Ir-J _ racket m Face of truss If no additinal floor area is created No Additional Sprinkler is Required. d U AquaSAFE Residential Fire Safety systems are often installed in attics or p q a rn w 3. THE DESIGN OF THIS SYSTEM IS DICTATED BY SPECIFIC CEILING HEIGHTS AND ROOM SIZES. IT IS THE Fire Sprinkler Adapter-\ - .-/ other areas exposed to temperature extremes of heat and/or cold. Follow 8'-0"or less O 2 u RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO ENSURE THAT THE CONDITIONS SHOWN ON THESE .LSI// - Mounting Bracket the recommended extreme weather installation instructions to isolate and / PLANS ARE EXACTLY AS THEY EXIST IN THE FIELD. DEVIATIONS FROM THE DESIGN MAY CAUSE THE > SYSTEM TO BE UNABLE TO CONTROL A FIRE.IF THE BUILDING CONSTRUCTION DIFFERS FROM THE FIRE protect system components from extreme temperatures. Because this RC-RES-16 w 3 0 w o SPRINKLER PLAN,CONTACT THE SYSTEM DESIGNER IMMEDIATELY. �} system also delivers domestic cold water directly to plumbing fixtures, ® N\ w v m z 3-#10 x 1 1/2" 9'-0"or less I- v N z a Full Course I t } Uponor highly recommends that you protect the tubing with adequate / �" w m r', u 4. THIS SYSTEM AND THE ACCOMPANYING HYDRAULIC CALCULATIONS ARE DESIGNED IN COMPLIANCE WITH 1Tr insulation in warm weather areas to minimize heatingof the cold water Thread Screws tl� \ In d w NFPA 13D 2016 EDITION. In Bottom Holes supply. _ ti ° z m oiT,41 5. "STAND-ALONE"OR"MULTIPURPOSE,WET PIPE"SYSTEMS ARE NOT PERMITTED TO USE ANTI-FREEZE. \ Installation methods include,but are not limited to: '11n m w a w • Tenting over the fire sprinkler piping. \ I ry o\ I �\ O,n H w 3 6. MODIFICATIONS ARE PROHIBITED.SPRINKLERS THAT HAVE BEEN PAINTED,CAULKED,MODIFIED OR Lead-Free.Flat -7 • Additional layers of batt insulation. If additional floor area is created.Cannot exceed 18 fS,be more than 2'-0" DAMAGED MUST BE REPLACED. Concealed Senju �'� Concealed Flat • Increased depth of blown-in insulation. deep,more than 9'-0"wide and be with in the coverage area of the o Sprinkler Head Cover Plate • sprinkler.No Additional Sprinkler is Required. z w v m z o i,,C 7. WATER SHUT OFF VALVE IS NOT PERMITTED THAT ISOLATES THE SPRINKLER SYSTEM. o z u LL z >F Caution: If you will be installing spray foam insulation,make sure to < o z o o 5 8. OWNERS MANUAL MUST BE PROVIDED TO THE OWNER. Senju RC-RES:Traditional Wood Framing Construction protect all components during application.Consult with the spray foam <z u❑5 o 0 o w9 5w manufacturer to ensure compatibility with all products before application. NFPA 13D Table 7.5.5.3 Distances From z g h¢ ,-.6,'„-f660 9. AT THE MAIN SHUT OFF VALVE,A TAG OR A SIGN STATING THE FOLLOWING IS REQUIRED;"WARNING,THE Heat Sources o ffi a v w o WATER SYSTEM FOR THIS HOME SUPPLIES FIRE SPRINKLERS THAT REQUIRE CERTAIN FLOWS AND Consultation with local building officials is encouraged to ensure compliance i_ LL v z z `" PRESSURES TO FIGHT A FIRE.DEVICES THAT RESTRICT THE FLOW OR DECREASE THE PRESSURE OR ProPEX L•Brass Fire with local building codes. 0<° r,.u z o 3 ' AUTOMATICALLY SHUT OFF THE WATER TO THE FIRE SPRINKLER SYSTEM,SUCH AS WATER SOFTENERS, Sprinkler adapter Tee Fire Sprinkler Adapter Ordinary Intermediate z . z SYSTEMS AND AUTOMATIC SHUT OFF VALVES,SHALL NOT BE ADDED TO THIS SYSTEM Push-on Nut Heat Source Temp. Temp. ''''.° 5 '-'5i.'07- FILTRATIONz r> v WITHOUT REVIEW OF THE FIRE SPRINKLER SYSTEM BY A FIRE PROTECTION SPECIALIST.DO NOT REMOVE ---Y- 135°-170° 175°-225° <z m r= z THIS SIGN". Bending PEX Tubing Side of Fireplace 3b" 12" 2 26_,, z x o `-u`C'" z s 11/4'Min. The minimum bend radius of Uponor PEX tubing in any direction is six times Front of Fireplace 60" 36" W>m o G G> <o z 3 10. ALL INTERIOR PIPING TO BE UPONOR"AquaPEX®"UNLESS NOTED. .�,- 1/'Max. the outside diameter(6 x OD). z 5.,,i,„,'-w' Fire Sprin ler Adapter - Bottom cf Mounting Bend supports are available for 3/8",1/2",3/4"and 1"Uponor AquaPEX Wood Burning Stave 42" 12" -0¢9-'x i V°, 7 -: 11. UPONOR"AquaPEX"TUBING TO BE SUPPORTED PER NFPA 13D AND MANUFACTURERS RECOMMENDATIONS. MountingBracket Bracket to ace of truss d=P p z i o c a v>3 z tubing to facilitate 90-degree rigid bends. Kitchen Range 18" 9" Q �,_J Wall Oven 18" 9" _I mz `-m',`v-' ud'0< w- 12. MINIMUM SPACING BETWEEN SPRINKLERS IS 8'-0" REFER TO SPACING CHARTS FOR MAXIMUM SPACING 2-#10 x 1/2" O ® V BETWEEN SPRINKLERS AND FROM WALLS.SPRINKLER HEAD MANUFACTURERS MAY HAVE MORE Recommended Tubing Length Between Fittings Hot Air Flues 18" 9" w w i C z ° z°° x> RESTRICTIVE SPACING LIMITATIONS. Full Cour-- _ -• v Thread S.rews Yi } Fitting Size Minimum Tubing Length Uninsulated Heat Ducts 18" 9" C m z u o u z}h s LL In Top H.les CJ 3/8"ProPEX Fitting 2., Uninsulated Hot Water Pipes 12" x$_o o 5 N°o 13. SPRINKLERS ARE NOT NECESSARILY CENTERED IN ROOMS DUE TO LIGHT FIXTURES OR OTHER CEILING Side of Hot Air Diffuser 24" 12" r z r F-3 N z,, , MOUNTED OBSTRUCTIONS. 1/2"ProPEX Fitting 2 1/2" i a y a 2 c a• w2-_,-.. Front of Hot Air Diffuser 36" 18" - ' c -o o z z 14. THE PLUMBING TIE IN CONNECTIONS ARE SCHEMATIC IN NATURE AND CAN BE INSTALLED OFF THE l 3/4"ProPEX Fitting 3 1/2" 3 0 =¢o v Lead-Fre=-Fla[� Hot Water Heater z p d< o SPRINKLER LOOP ANYWHERE BETWEEN SPRINKLER TO SPRINKLER CONNECTION. - -to 3 c o o w : o 2 o»o Conceale•Senlu \ -- Concealed Flat 1"ProPEX Fitting 4 1/2" Furnace 6" 3" o moa > > Sprinkler Head 50W-250W Light Fixture 6" 3" ' 'o y i_Y u w z z z 15. THIS SUGGESTED LAYOUT IS BASED UPON INFORMATION PROVIDED BY OTHERS. CHANGES IN Cover Plate 1 1/4"ProPEX Fitting 5 1/2" 9 >=o 2 x x v o 3 CONSTRUCTION OR FIELD CONDITIONS MAY OCCUR WHICH MAY REQUIRE CHANGES TO THE LAYOUT. IT IS 25OW-499W Light Fixture 12" 6" n i 5 2 ,,,-.=.,,, ,f155 THE RESPONSIBILITY OF THE INSTALLER TO NOTIFY UPONOR TECHNICAL SERVICES OF SUCH CHANGES. "z z ,❑cJ am°'.;= 16. NFPA 13D 8.2.5*OBSTRUCTIONS TO RESIDENTIAL SPRINKLERS Exposed Installation Requirements. • 8.2.5.6° SHADOW AREAS SHALL BE PERMITTED IN THE PROTECTION AREA OF A SPRINKLER AS LONG AS Uponor tubing(white)and ProPEX'"'EP Fittings and ProPEX'" \ I THE CUMULATIVE DRY AREAS DO NOT EXCEED 15 FT'PER SPRINKLER. Brass Fittings are are approved for exposed installation where the following • 8.2.5.7 SMALL AREAS CREATED BY ARCHITECTURAL FEATURES,SUCH AS PLANTER BOX WINDOWS,BAY conditions are met.(UL 1821 Approved) WINDOWS,AND SIMILAR FEATURES,SHALL BE EVALUATED AS FOLLOWS: Co (1)WHERE NO ADDITIONAL FLOOR AREA IS CREATED BY THE ARCHITECTURAL FEATURE,NO Exposed Wood Joist Ceiling Assemblies. o .1 /5 im ADDITIONAL SPRINKLER PROTECTION IS REQUIRED. 1. Joists are of dimensional lumber,engineered wood,wood Hoist or open `x m I here by certify that this plan,specification, (2)WHERE ADDITIONAL FLOOR AREA IS CREATED BY AN ARCHITECTURAL FEATURE,NO ADDITIONAL web wood joists. or report was prepared by me or under my SPRINKLER PROTECTION IS REQUIRED,PROVIDED ALL OF THE FOLLOWING CONDITIONS ARE MET; m 2. Joist are of depths from 6-16 inches(152-204 mm). (a)THE FLOOR AREA SHALL NOT EXCEED 18 FT°(1.7 M5( direct supervisiont and that I am NICET 3. Joist are of spacing from 12-24is inches(305-610 mm)on center. ❑ Certified at Level IV. (b)THE FLOOR AREA SHALL NOT BE GREATER THAN 2 FT IN DEPTH AT THE DEEPEST POINT OF Ea 4. Joists can be exposed aftereinstallation. \ THE ARCHITECTURAL FEATURE TO THE PLANE OF THE PRIMARY WALL WHERE MEASURED 5. Metal pipe hangers spaced at maximum 24 inches(610 mm)on center 1.55" / 1.66" ALONG THE FINISHED FLOOR. are used. Brent D Kotula Ri (c)THE FLOOR SHALL NOT BE GREATER THAN 9FT IN LENGTH WHERE MEASURED ALONG THE 6. Listed residential automatic sprinklers of maximum activation in 3n Han er 1" Han er PLANE OF THE PRIMARY WALL. temperature rating of 155°F(68°C), 4 g g Date: Reg.No.113889 .: (d)MEASURED FROM THE DEEPEST POINT OF THE ARCHITECTURAL FEATURE TO THE SPRINKLER ry SHALL NOT EXCEED THE MAXIMUM LISTED SPACING OF THE SPRINKLER. Tubing Support Spacing: `" (3)THE HYDRAULIC DESIGN SHALL NOT BE REQUIRED TO CONSIDER THE AREA CREATED BY THE Metal Tubing Support.sdesigned AquaPEX Tubing Securely Enough to Support the Tubing,Yet Relaxed 0 ARCHITECTURAL FEATURE. 1. Metal tubing supports designed for plastic tubing shall be used. Enough to Allow the Tubing to Expand and Contract) 2. Do not use supports that will damage the tubing.Inspect metal 0 17. NFPA 13D 8.3 LOCATION OF SPRINKLERS. supports for sharp edges. 1. AlongHorizontal Runs,Install 3. Do not rigidly anchor Uponor Aqua PEX"tubing with supports.Allow Supports Every 32",if Horizontal Runs are 8.3.1 SPRINKLERS SHALL BE INSTALLED IN ALL AREAS EXCEPT WHERE OMISSION IS PERMITTED BY 8.3.2 Continuously Supported,Place Tubing Supports at Six-Foot Intervals. • THROUGH 8.3.8. enough tubing for freedom of movement to expand and contract. 2. Along Vertical Runs,Install Supports Every Four to Five Feet,at Each `-' • 8.3.2 SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55 FT°(5.1 M')AND LESS Floor and at a Mid-story Guide. to • 8.3.3 SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS,LINEN CLOSETS,AND PANTRIES THAT E MEET ALL OF THE FOLLOWING CONDITIONS: m a In-line Flow Test (1)THE AREA OF THE SPACE DOES NOT EXCEED 24 FT'(2.2 M°). .°-' o (2)THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLEThe In-line Flow Test can be constructed on site. It performs a flow test to n 0 - 16°` MATERIALS AS DEFINED IN NFPA 220,STANDARD ON TYPES OF BUILDING CONSTRUCTION. Standard Riser system Assemblyp,c o ensure proper system operation and flow(see Figure F001-8). In a multi-purpose systema single control valve controls both domestic and ` 2 H o, H • 8.3.4* SPRINKLERS SHALL NOT BE REQUIRED IN GARAGES,OPEN ATTACHED PORCHES,CARPORTS,AND ) z w \ u `S SIMILAR STRUCTURES fire safety needs. V a m e^.o 0 5 • 8.3.5 SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS WITH OR WITHOUT STORAGE,PENTHOUSE / Uponor AquaPEX a ti EQUIPMENT ROOMS,ELEVATOR MACHINE ROOMS,CONCEALED SPACES DEDICATED EXCLUSIVELY TO AND Tubing Q CONTAINING ONLY DWELLING UNIT VENTILATION EQUIPMENT,FLOOR/CEILING SPACES,ELEVATOR SHAFTS, / j w z CRAWL SPACES,AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING cc j m o PURPOSES. j �, j j z W O 1. •• 8.3.5.1 SUCH SPACES THAT CONTAIN FUEL-FIRED EQUIPMENT SHALL ALSO COMPLY WITH 8.3.5.1.1 OR Ce = 6 0 ..a 8.3.5.1.2. F r=u �, ' • UNIT, .1 WRINK TRE FUELCTION SHAILMENRIS IRED ALL EF THE OCCUPIED AREAS OF THE DWELLING j j LLJM F Ga a p o, UNIT,NO SPRINKLER PROTECTION SHALL BE REQUIRED IN THE CONCEALED SPACE. ,_,r w U 8.3.5.1.2 WHERE FUEL-FIRED EQUIPMENT IS BELOW OR ON THE SAME LEVEL AS OCCUPIED AREAS OF THE 1---1 N o O o 4 of x,n w L' • DWELLING UNIT,AT LEAST ONE QUICKRESPONSE INTERMEDIATE TEMPERATURE SPRINKLER SHALL BE Male Threaded Coupling ProPEX Fire 7 N u u u a a v�z0 p INSTALLED ABOVE THE EQUIPMENT OR AT THE WALL SEPARATING THE SPACE WITH THE FUEL-FIREDceD Sprinkler Adapter L u: EQUIPMENT FROM THE OCCUPIED SPACE. w • 8.3.6 SPRINKLERS SHALL NOT BE REQUIRED IN COVERED,UNHEATED PROJECTIONS OF THE BUILDING AT - _ 1"Ball Valve ..CA ENTRANCES/EXITS AS LONG AS THE DWELLING UNIT HAS ANOTHER MEANS OF EGRESS. To Hot Water Heater Male Threaded Coupling -- o �_- WTI o • 8.3.7 SPRINKLERS SHALL NOT BE REQUIRED FOR CEILING POCKETS THAT MEET THE FOLLOWING :tif Female Threaded C aC' CONDITIONS: 12 E -. , Teesure Water Cez (1)THE TOTAL VOLUME OF ALL UNPROTECTED CEILING POCKETS INA COMPARTMENT DOES NOT EXCEED - Pressure Gauge > O o 100 FT,(2.83 Ma) = Sprinkler Orifice - (Optional) 7 m (2)THE ENTIRE FLOOR UNDER THE UNPROTECTED CEILING POCKET IS PROTECTED BY THE SPRINKLERS F - II Z o 5 -' a,0 AT THE LOWER CEILING ELEVATION. E 3 Uponor Warning Signs H 0 ' z 2 8 UI Q, (3)*THE INTERIOR FINISH OF THE UNPROTECTED CEILING POCKET EXCLUDING DECORATIVEft Flow Test �.�/ F w To ensure the system provides enough water for proper fire sprinkler L.L a m ut.�. m TREATMENTS IS NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE MATERIAL. to o (4)SKYLIGHTS NOT EXCEEDING 32 FT'(2.97 M°)SHALL BE PERMITTED TO HAVE A PLASTIC COVER. performance,you should conduct a flow verification test. J o • 8.3.8 SPRINKLERS SHALL NOT BE REQUIRED IN CLOSETS IN GARAGES AND EXTERIOR CLOSETS - - H Q y f I- F iL (REGARDLESS OF SIZE)LOCATED ON EXTERIOR BALCONIES,EXTERIOR BREEZEWAYS/CORRIDORS,OR _ p Note: The NFPA 13D Installation Standard does not require flow D /r1 5 y m z ¢0 S ACCESSED FROM OUTDOORS WHERE THE CLOSET DOES NOT HAVE DOORS OR UNPROTECTED verification. lJ too z" m PENETRATIONS DIRECTLY INTO THE DWELLING UNIT. El Main Fire Sprinkler 7 ~ G 3 5 S 5 z • 8.3.9 SPRINKLERS SHALL BE INSTALLED IN ANY CLOSET USED FOR HEATING AND/OR AIR-CONDITIONING - = Shut-off Valve Before performing ae flow verification test,confirm the water pressures by ` w F EQUIPMENT,WASHERS AND/OR DRYERS,OR WATER HEATERS EXCEPT AS ALLOWED BY 8.3.8. contacting the Water and Sewer Department of your local city. Ensure the a 0 u d z tz - available water pressure matches the pressure used in the system design. 18. INSULATION GUIDE LINES PER NFPA 13D. - Note: The sprinkler plan indicates the most hydraulically remote sprinkler SHEET DESCRIPTION • 9.1.1*WET PIPE SYSTEMS IN AREAS ABOVE 40°F. A WET PIPE SYSTEM SHALL BE PERMITTED TO BE TO BE - (or pair of sprinklers). For test requirements on other sprinklers,consult GENERAL NOTES&DETAILS USED WHERE ALL PIPING IS INSTALLED IN AREAS MAINTAINED ABOVE 40°F,INCLUDING AREAS PROPERLY your local code. . INSULATED TO MAINTAIN 40oF. •• A.9.1.1 IN AREAS SUBJECT TO FREEZING,CARE SHOULD BE TAKEN IN UNHEATED ATTIC SPACES TO Note: It is a good idea to notify the fire inspector at least 24 hours prior to o' COVER SPRINKLER PIPING COMPLETELY WITH INSULATION. INSTALLATION SHOULD FOLLOW THE performing a flow verification test. This may speed up the inspection ,p GUIDELINES OF THE INSULATION MANUFACTURER.FIGURE A.9.1.1(A)THROUGH FIGURE A.9.1.1(F) process and eliminate the need to repeat the test for the inspector. SHEET NUMBER o SHOW SEVERAL METHODS THAT CAN BE CONSIDERED. THESE ARE FOR ILLUSTRATIVE PURPOSES ONLY. ^�' CONSULTATION WITH THE GENERAL CONTRACTOR AND/OR OWNER IS RECOMMENDED TO ENSURE Note: See"AquaSAFE Flow Test Instruction Sheet"(Provided in S PROPER METHODS AND MATERIALS ARE USED TO MAKE SURE 40°F WILL BE MAINTAINED. ! _ Contractors Documents package or online at www.Uponorpro.com)for more information on Flow Test Setup,Assembly,Performing the Test and Troubleshooting. If there are any questions please contact Uponor. F- © UPONOR - CONFIDENTIAL FO 0 1