Loading...
Permit (44) CITY OF TIGARD MASTER PERMIT .111.„,„ ti r, ' COMMUNITY DEVELOPMENT Permit#: MST2016-00466 T jGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 08/03/2017 Parcel: 1 S 135AD03500 Jurisdiction: Tigard Site address: 8723 SW SPRUCE ST Subdivision: 1990-053 PARTITION PLAT Lot: 3 Project: Hall Pointe Townhomes Project Description: Building C-New SFA BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 2 First: 590 sf Basement: sf Left: Parking Spaces: Height: 28 Bathrooms: 3 Second: 600 sf Garage: sf Front: Smoke Dwelling Units: 1 Third: sf Detectors: Yes Right: Total: 1190 sf Value: $138,249.26 Rear: PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 LaundryTrays: 0 Y Rain Drain: 1 Urinals: 0 Lavatories: 4 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer 100 Tubs/Showers: 2 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Drains: 0 Bckflw Prevntr: 0 Catch Basins: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 0 Backwater Value: 1 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 4 Clothes Dryers: 1 Natural Gas Heat Pump: Y Hoods: 1 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 4 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 1 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener N Other: N Other Description: All Ecompasing: Y BUILDING INFO Class of Work: Type of Use: Type of Constr: NEW Occupancy Group: Square Feet: SFA VB R-3 1190 Owner: Contractor: DAVIS,EUGENE REVOCABLE LIVING T RICH DUNCAN CONSTRUCTION INC Required Items and Reports(Conditions) BY DAVIS,EUGENE LOREN TR 2295 RURAL AVE SE 1 Ersn Cntrl 503-639-4175 10875 SW 89TH ST SALEM,OR 97302 TIGARD,OR 97223 PHONE: 503-246-5862 PHONE: 503-390-4999 FAX: Total Fees: $20,460.44 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-00 090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1,800.332.2344. Issued By: IAir I� � ► Permittee Signature: Ce-z'_ //�✓//r- � Call 503.639.4175 by 7:00 a.m.for the next available inspection date. / / This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. BuildingPermit Application 0y'"CF I VI?P Residential 1 OR€31 11( 1:I.s1 O!i 1 / CityofTigard 2016 IIIDaeB �f© , 11)16 Permit No.:I-Kiva'-tiycC�, • 13125 SW Hall Blvd.,Tigard,OR 97223 t;. I ;ti @_ Pian Revie _ ►+� ether Permit:�wi�2of j�- 3 i Phone: 503.7182439 Fax: 503 598.146{& ' x ,i(a;\i J DateBy: / TI GARD; Inspection Line: 503.639.4175 „„„.„„1,,T,. ,f ,, , Date Ready/By: /Iris El See PaGge2for Internet: www.tigard-or.gcr ij La:3i'NC Ft lV13i 111 Notified/Method; Supplemental Information TYPE OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING ft New construction 0 Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all 0 Addition'alteration/replacement 0 Other: equipment materials,labor,overhead.and the profit for the CATEGORY OF CONS"TRUCTIO work indicate- on. this application. ►� I-and 2-family dwelling 0 Commercial/industrial Valuation: $134; J } Number of bedrooms: 2 '` (� ❑Accessory building 0 Multi-family 13 S' a.4 1- 0 Master builder 0 Other: Number of bathrooms: 2.5 JOB SITE INFORMATION AND LOCATION Total number of floors: 2 Job site address: SW Spruce St SI Z3 New dwelling area: 1190 square feet City/State2lP:Tigard,OR 97223 Garage/carport area: square feet Suite/bldg./apt.nia ; Project name:Hall Pointe Townhomes Covered porch area: X17 square feet C,CND Cross street/directions to job'site:SW Spruce St and Hall Blvd Deck area: 91 square feet s”q 0 Other structure area: z-fieD square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all Tax map/parcel no.: equipment.materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. �190 sq ft 2 story townhouse built to Oregon Residential Specialty Code,2014 ed Valuation: $ '- Existing building area: square feet New building area: square feet �d PROPERTY OWNER 0:TENANT Number of stories: Name:E&V Devlopment,LLC TYpe of construction: Address:10879 SW 89t5 Ave Occupancy groups: City/State'ZIP:Tigard,OR 97223 Existing: Phone:(503)246-5862 Fax:(N/A) New: C, APPLICANT >I`CONTACT PERSON BUILDING PERMIT FEES* (Pieese refer to fee scheduteei Business name:Rich Duncan Construction Structural plan review fee(or deposit): Contact name:Chad Elliott 503-910-0897 —~ FLS plan review fee(if applicable): Address: 2295 Rural Ave SE — Total fees due upon application:City/State/ZIP;Salem,OR 97032 65;..* 1 Phone:(503,1390-4999 Fax::# Amount received:503)390-3633 PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* E-mail:chadvrichduacancanstruction.cam Comm-rcial and residential prescriptive installation of CONTRACTOR roof-top t ounted PhotoVoltaic Solar Panel Systet•. Business name:Rich Duncan Construction Submit two 2)sets of roof plan with conn-. ': details — and fire depat 1 -,t access.al.t• I e 2010 Oregon Address:2295 Rural Ave SE Solar Installation .1,- ". _ ode checklist. City/State/ZIP:Salem,OR 97032 Pe �inclu, plan review 5180.00 and administrative fees): Phone:(503 1 40993 9 D-49.9 5 Fax:(503)399-3633 State surcharge(I2%of permit fee) 521.60 ^ — 'CB lic.:158330 Total fee due upon application: ` 60 — Authorized signature: This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name:CHAD ELLIOTT I Date: 10/13/16 *Fee methodology set by Tri-County Building Industry, I Service Board. I:\Building'Permits\BUP-RESPermitApp.=:oc 02/24/2011 440-4613T(11/02/COM/WEL') 1 E �',.._,4 '1 . Mechanical Permit Application =, City of Tigard ! tN01mr!.o �Jg <�Z Ccs ] 13125 SW Hall Blvd.,Tigard,OR 97223 0 U > d 8 _''!' Plan Review ■ Phone: 503.718.2439 Fax: 503.598.1960 Other Permit: Date/By: T I c A R D Inspection Line: 503.639.4175 , , ' ' :''3 Date Ready/By: Juris: ® See Page 2 for Internet: www.tigard-or.gov - Notified/Method: Supplemental Information Pili TYPE OF WORK COMMERCIAL FEE* SCHEDULE –USE CHECKLIST Mechanical permit fees*are based on the value of the work 1/ New construction 0 Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all ❑Demolition 0 Other: mechanical materials,equipment,labor,overhead,and profit. Value:$ CATEGORY OF CONSTRUCTION RESIDENTIAL EQUIPMENT/SYSTEMS FEES* ® 1-and 2-family dwelling 0 Commercial/industrial 0 Accessory building For special information use checklist. ❑Multi-family 0 Master builder 0 Other: Description Qty. Ea. Total JOB SITE INFORMATION AND LOCATION Heating/cooling: Air conditioning 46.75 Job site address: SW Spruce St S1 .3 Furnace 100,000 BTU(ducts/vents) _ 46.75 City/State/ZIP:Tigard,OR 97223 Furnace 100,000+BTU(duets/vents) _ 54.91 Heat pump 61.06 Suite/bldg./apt.no.: Project name:Hall Pointe Townhomes Duct work 23.32 Cross street/directions to job site:SW Spruce St&Hall Blvd Hydronic hot water system 23.32 Residential boiler(radiator or hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Subdivision: Lot no.: Other: 23.32 Other fuel appliances: Tax map/parcel no.: Water heater 23.32 DESCRIPTION OF WORK Gas fireplace/insert 33.39 Flue vent for water heater or gas installation of 4 remote heads for a"mini-split"system,misc sheet metal vents fireplace 23.32 or microwave unit,dryer,and bath exhausts Log lighter(gas) 23.32 Wood/pellet stove 33.39 Wood fireplace/insert _23.32 Chimney/liner/flue/vent 23.32 ® PROPERTY OWNER 0 TENANT Other: 23.32 Environmental exhaust and ventilation: Name:E&V Development<LLC Range hood/other kitchen equipment 33.39 Address:10879 SW 89"'Ave Clothes dryer exhaust 33.39 City/State/ZIP:Tigard,OR 97223 Single-duct exhaust(bathrooms, toilet compartments,utility rooms) 23.32 Phone:(503)246-5862 Fax:(N/A) Attic/crawlspace fans 23.32 0 APPLICANT ►Zi CONTACT PERSON Other: 23.32 Business name:Rich Duncan Construction,LLC Fuel piping: $14.15 for first four;$4.03 for each additional Contact name:Chad Elliott 503-910-0897 Furnace,etc. Address:2295 Rural Ave SE Gas heat pump - Wall/suspended/unit heater City/State/ZIP:Salem,OR _Water heater Phone:(503)390-4999 Fax::(503)390-3633 Fireplace Range E-mail:chad@richduncanconstruction.comRich Barbecue CONTRACTOR Clothes dryer(gas) Busine Other: Advanced Mechanical Services MECHANICAL PERMIT FEES* Addre: PO Box 1699 — Subtotal city/S: McMinnville, OR 97128 Phone: 503-434-8544 J Minimum permit fee($90.00) CCB: 194814 Plan review(25%of permit fee) or►e: State surcharge(12%of permit fee) CCB li. _ TOTAL PERMIT FEE This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Authorized signature: ‘4\\\A\\, * Fee methodology set by Tri-County Building Industry Service Board Print name:CHAD ELLOTT Date:10/13/16 IaBuilding\Permits\MEC PemritApp_040113.doc 4404617T(11/02/COM/WEB) • IA Fl V Electrical Permit Application I-I)R(11 VI( I I SI-u v l City of Tigard AUG 2, ?_017 Received Penni d: 13125 SW Hall Blvd.,Tigard,OR 97223_ Date/II ' , 1 sr�/'t y :' = Phone: 503.718.2439 Fax: 503.5�18� ,r ,, ^."( L P Review Related Permit N: - Inspection Line: 503.639.4175 o.Lsr i Ret sP Ready Date/By: Suns: $See Page TI(;ARLp -5-��; "i � �' t p; sg Efor Internet: www.tigard-or.gov I J 1 a i�G� V o j 3.) ,i Notified/Method: Supplemental Information :��:' "�" e _ T.;•rrxr Pico-- 'r^.,, p bye.. .,.:fx-,s^.t_4^t`a„•.:3'f3�=01%vR4�i:-34-?"'.•.:�$•,.%"•=n, ci ''•_ r.crg �---,- :.N-.. :S ��� ,.-, �fi...w.-,.;z:�c�sr�::��'+��.��,-�.i�L�.!a,;�.".'-''..-�.`�^.s::�=•.'�''•,i-a`="'.x:�:'�=�-,-.z-...•r. �='rte`." G�;>..�..-�;`,��s'�'�--'+' 'v '""," .�' � .,rte-•'..,�. ' i•Ss gvYGr.`.:.��".»ri�-'tus�� .��ra,;~'��."�r`n �•�::rry Q New construction 0 Addition/alteration/replacement Please check all that apply(submit j sets of plans w/items checked): 0 Demolition Other; 0 Service or feeder 400 amps or more ❑Building over three stories. µ the eaverteu t entrant ry a rd s. Su ,t:fwM� � . . 0010 ^ *lt1iran` � arai � 'weeds 10.000 amps at t O volts o ❑Flotg buildings 1-and 2-family dwelling 0 Commercial/industrial 0 Accessory building less to ground,or exceeds 14.000 0 Carmnercialwse agricultural amps for all installations. buildings.❑Master builder ❑Other: ❑Fire pump. 0 Installatio nofIS0KVA or Pr • � Y_ i.� ' .� = - ?rMELWzg10 Emergencysystem. larger separately derived Job#: Job site address: ?jSW Spruce St 0 Addition of new motor load of system. IOOHP or more. ❑"A""E""1-2""1-3 City/State/ZIP:Tigard,OR 97223 Roc 0 six or more residential units. anion 0 Health-care facilities. 0 Recreational vehicle parks. Suite/bldg,/apt.#: C, ,Project name: Hall Pointe Townhomes 0 Hazardous locations. 0 Supply voltage for more than 0 Service or freder 600 amps or more. 600 volts nominal. Cross street/directions to_job site: Hall Blvd&SW Spruce St - . a { < ; , ---r;�. �.~..+;t.•^.�'+r��,3.rE~k'{�ft .�*.e,':'�'^..,".l'd �:;�,. Y".t'.XE.�sic'- .aerieuea I thy. (. Ugh 1 Total L New residential single-or multi-family dwelling unit. Subdivision: Lot#: Includes attached garage. m #: 1S135AD03500 1• sq.ft.or less f 168.54 f jib, 4 :'Tax map/parcel n`''om er x .,._.... �{� may x.,> <sx F_ s,a� ;w Ea.add'l 500 sq.ft.or portion 33.02 35:17. I ..,..rF..'u::SNRP- r r:--.".-R"'r„ux..:�1 '!!tf�:,'Ji.,. +:d!:i ,f'.-�".'t'=< "'�c-Y':rxR'' +`'.. ...r•.a":"s,:... Limited energy,residential 7500 2 (with above sq.ft.) Limited energy,multi-family 75 2 residential(with above sq.ft.) �`���y:� _ - - .i, ���=" �f"'s`;^.'��.,«.� _.w_ y.�=�c:;=;,�:t'��"s-i= Reaewabte Euerat`v C]3tx Page Z .Tr,.:;;.,: s.-.,.; ;wti�?ro3=`;zr%=-Kis; ;. .. '.' —...,, '�� "''' '�;':-:�'�°�='-_'� Services or feeders Itis illation,alteration,andlor e+ettsation Name: 200 amps or less j 100.70 jpp.70 2 Address: 201 amps to 400 amps 133.56 2 City/State/ZIP: 401 amps to 600 amps 200.34 2 601 amps to 1,000 amps 301.04 2 Phone:( ) Fax;( ) Over 1.000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email: relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 Kms✓�, v'�.A.-. . ,�. ,;�,,-:Yom; - t F .;, :. ? , ;i s==-rn:n,.;:-n Branch Circuits- neW,alteration,or extension,per panel . � `£"r "'."`: ",'::�` ��' �"'"i'"``""�`* A.Fee fot branch circuits with Business name: E&V Development above service or feeder fee, 7 A2 2 each branch circuit Contact name: Dr.Gene Davis B.Fee for branch circuits without • Address: 10875 SW 89th Ave service or feeder fee,first 5618 2 branch circuit City/State/ZIP: Tigard,OR 97223 Each add'l branch circuit 7.42 2 Miscellaneous(service or feeder not included) • Phone:(503)887-9966 Fax::( ) Each manufactured or modular dwelling,service and/or feeder 67'84 2 Email: fmfindia@ • a oo corn Win^ Reconnect only 6784 2 bT%'.: - ell . e - nrz. -`'";F,'" Pump or irrigation circle 67.84 2 Business name: ProTech Power Sign or outline lighting 67,84 2 • Address: 17937 McEwen Rd#200 Signal circuit(s)or limited-energy .See Page 2 2 panel•alteration,or extension. City/state/ , Portland,OR 97224 Each additional inspection over allowable in any of the above Additional inspection(1 hr mita) 66.25/hr Phone:( 503)780-6207 Fax:( ) Investigation(1 hr min) 90.00/hr • Email: Industrial plant(1 hr min) 78.18/hr • Inspections for which no fee is CCB Lie.: 198878 Electrical 1.' ,: C916 ' Pry.Lt•ri.' 6125S specifically listed eh hr min 9000/hr r.;rr: K�...:s.,....,..`=`s;!Y!0.11!ia,AM�? _ 'r ry::r;t Suprv.Electrician signature,required: i1 I '"`'` "'"' "''1 mow+ Subtotal: 30.414 Print name: Andrew Anderson Da 8/2/2017 0 Plan Review Required(25%of permit fee): State surcharge(12%of permit fee): Authorized signature: TOTAL PERMIT FEE: Print name: This permit application expires if a permit is not obtained within ISO Date: days after it has been accepted as complete. • Number of inspections allowed per permit. • 1 klituldipgt\Permes5EL( Petmit.4pp_ELR_ERE.doc Rev 06,17/2015 440-46151(1 t/O5MOMM'EB 1 ` Plumbing Permit Applic t v4n , i'° , l BuildingFixtures =~" roa olrlcr 1'SI: o\11 City of Tigard Received V Date/By: IIII Permit Nopco/6)'`0696 013125 SW Hall Blvd.,Tigard,OR 9722 PlanRe view 111 Phone:411) . . Date/By: Other Permit No.: TIGnzDInspection Line: 503.639.4175 J - Internet: www.tigard-or.gov Date Ready/By: Juris: ifi See Page 2 for i���as 4 ��..- 1��� Notified/Method: Supplemental Information TYPE FEE* SCHEDULE ®New construction 0 Demolition For s ecial in ormation use checklist. - Description Qty. i Ea. Total ❑Addition/alteration/replacement 0 Other: New 1-2-family dwellings(includes 100 ft.for each utility connection) CATEGORY OF CONSTRUCTION SFR(1)bath 312.70 ►.1 1-and 2-family dwelling ElCommercial/industrial SFR(2)bath 437.78 SFR(3)bath 500.32 ❑Accessory building 0 Multi-family ❑Master builder - Each additional bath/kitchen 25.02 0 Other: Fire sprinkler( sq.ft.) Page 2 JOB SITE INFORMATION AND LOCATION Site utilities: - Job site address: SW Spruce St 8/ 5 Catch basin or area drain 18.76 City/State/ZIP:Tigard,OR 97223 Drywell,leach line,or trench drain 18.76 Footing drain(no.linear ft.: ) Page 2 Suite/bldg./apt.no.: Project name:Hall Point Townhomes - Manufactured home utilities 50.03 Cross street/directions to jolt site:SW Spruce St and Hall Blvd Manholes 18.76 Rain drain connector 18.76 Sanitary sewer(no.linear ft.:_) Page 2 Storm sewer(no.linear ft.:_) Page 2 - Water service(no.linear ft.: ) Page 2 Subdivision: Lot no.: Fixture or item: Tax map/parcel no.: Backflow preventer 31.27 DESCRIPTION OF WORK Backwater valve 12.51 Clothes washer 25.02 •ough and finish plumbing for 1190 sf2 steory townhome with 2 and 1/2 bath, Dishwasher 25.02 laundry,kitchen.Water and sewer on site Drinking fountain 25.02 Ejectors/sump 25.02 0 PROPERTY OWNER ❑ TENANT Expansion tank 12.51 Name:E&V Development,LLC Fixture/sewer cap 25.02 Address:10879 89th Ave Floor drain/floor sink/hub 25.02 Garbage disposal 25.02 City/State/ZIP:Tigard,OR 97223 - Hose bib 25.02 Phone:(503)246-5862 Fax:(N/A) Ice maker 12.51 ® APPLICANT 0 CONTACT PERSON - Interceptor/grease trap 25.02 Business name:Rich Duncan construction Medical gas(value:$ ) page 2 Contact name:Chad Elliott 503-910-0897 Primer 12.51 - Roof drain(commercial) 12.51 Address:2295 Rural Ave SE Sink/basin/lavatory 25.02 City/State/ZIP:Salem,OR 97032 Solar units(potable water) 62.54 Phone:(503)399-4999 Fax::(503)390-3633 Tub/shower/shower pan 12.51 E-mail:charichduncanconstruction.com Urinal 25.02 d@ CONTRACTOR Water closet 25.02 Water heater 37.52 Bu' .-- York Custom Mechanical - Water Waterpiping/DWV 56.29 Ad PO Box 21474 _ Other: 25.02 Cit Keizer, OR 97307 Phone: 503-584-1771 _ Subtotal Pht CCB: 203341 Plumbing: PB 1481 Minimum permit fee: $72.50 SE_ - Plan review (25%of permit fee) State surcharge(12%of permit fee) Authorized signature: TOTAL PERMIT FEE Print name:CHAD ELLIOTT Date:10/13/16 This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. *Fee methodology set by Tri-County Building Industry Service Board. I.\Building\Permits\PLMU-PermitApp.doe 10/01/09 440-4616T(10/02/COM/WEB) City of Tigard ~ COMMUNITY DEVELOPMENT DEPARTMENT : ■ T 1 cA R n Building Permit Review — Residential Building Permit #: /17S7- 2,9/6) -- 00 6 Site Address: -).P--3 S/, or2t!e Project Name: �`/ Pe/h71 nhoyye c Lot #: (New dwelling=subdivision name;Addition or Alteration=last name of owner) Planning Review Proposal: ki ) S)F/ct Verify site address/suite# exists and acttiiv$,in permit system. Liver Terrace Neighborhood: 114 No ❑ Yes,See River Terrace Review Addendum Attached Sit Plan Elements: tree(3)copies of site plan ting structures on site o plan must be on 8-1/2"x 11"or 11 x 17"paper +r44.4". . ,tOtWorUnKtUre'**chiddecks)with fittigted Vi Drawn to scale(standard architect or engineer scale) il-, k �'. a� ' #,,ortli nrn w liviOiti v.ttility locations(required for new,may apply for additions) rite address,project or subdivision name and lot number cation of wells/septic systems pplicant information(name and phone number) fisting trees to be retained with drip line,and tree VISLot dimensions and building setback dimensions irotection measures t rpt? tam & 4 r ,,k.< $ ,.�' eet tree size,type and location ` s • area.( if s ° R'41 `- a �_ fAStreet names /.� (a(� .x,-, b. .:A + s (2 foot/con+o u 1,'f'Emote ta.', p ��)()( ' . t ',F "�rtZpi^ e. W� NSW./` ,. a , .,dt32., I P iL0-4C e'S.A,,., ?Alt s-o.1. 'J ii lean Water Services—Service Provider Lett (lot platted prior to 9/10/1995): ,Required: ❑ Yes,applicant was notified PO No Received: ❑ Yes ❑ No Pig Public Facilitie Improvement(PFI) Permit: Required: TrYes,applicant was notified ❑ No Applied For: /Yes ❑ No,stop intake Land Use Case#: S'Ae0I�=C29��c- Zoning: Mu/2-cQ V Required Setbacks: Front . Rear 0 Sides 0 Street Side �/� Garage 6andscape Requirement: % SII /&'Oil klegf S1Cle_ ,ot Coverage Maximum: st, • RIMYBuilding Height: Maximum Height ZAS-- Actual Height 6,73 0 l isual Clearance Al asements 'ensitive Lands: ❑ Yes V/No Type 1. Urban Forestry Plan ❑ Conditions "Met"prior to issuance of building permit > Notes: (174 / /a �' i , dor 7� C').#70.107et . 'i t 1y) Albite` cr7-1l / /0174? "In/ 1. .cel Z Approved By Planning: Date: /0 — /8—,4 Revisions (after Building Submittal only) Reviewer Date Revision 1: ❑ Approved ❑ Not Approved Revision 2: ❑ Approved ❑ Not Approved Revision 3: ❑ Approved ❑ Not Approved l:\Building\Forms\BldgPermitRvw REs 091216.docx Building Permit Submittal Original Submittal Date: /01t//,6 Site Plans: # 3 Building Plans: # Building Permit#: ©--Enter building permit#above. Workflow Routing: P.-Planning E3' Engineering CSI ermit Coordinator '1i Building Workflow Sign-off: yl'Sign-off for Planning(include notes from planning review) Route Application Documents: ❑-Engineering: (1) copy of permit application,(1) site plan, (1) building plan and original plan review routing form. Building: original permit application, site plans,building plans,engineer and beam calculations and trust details,if applicable, etc. Notes: By Permit Technician: 6), i Date: ///3�IA, Engineering Review Slope at building pad: 1 ,.) ,.. 0 Conditions"Met"prior to issuance of building permit ❑ Easements (encroachments)per engineering conditions of approval and plat ❑ Water Quality/Quantity Facility: Assess Water Quality Fee in-lieu: ❑ Yes ❑ No Assess Water Quantity Fee in-lieu: ❑ Yes ❑ No LIDA Facility on lot: ❑ Yes ❑ No ❑ NOT Approve by ngineering: Date: Notes: G /Z240-5- / 1 4/ J 4s- tom' / Approved by Engineering: , Date: /�11 Revisions (after Building Submittal only) Reviewer Date Revision 1: ❑ Approved ❑ Not Approved Revision 2: ❑ Approved ❑ Not Approved Revision 3: ❑ Approved ❑ Not Approved igamonssimazasmaseetensgar Permit Coordinator Review ❑ Conditions "Met"prior to issuance of building permit °approved,NOT Released: )(90.-Date: /i[�/tf l Notes: Revisions (after Building Submittal only) Revision Notice 1: Date Sent to Applicant: Revision Notice 2: Date Sent to Applicant: Revision Notice 3: Date Sent to Applicant: 'SDC Fees Entered: Wash Co Trans Dev Tax: 0es ❑ N/A f Tigard Trans SDC: Yes ❑ N/A Parks SDC: ►'Yes ❑ N/A �► `'.."to Issue Permit • pproved byPermit Coordinator: �'a Date: (4.77-�� I:\Building\Forms\BldgPermitRvw_RES_091216.docx Albert Shields From: Albert Shields Sent: Monday, November 07, 2016 2:40 PM To: 'chad@richduncanconstruction.com' Subject: RE: MST2016-00463, -00464, -00465, -00466 Hall Pointe Townhomes And the same story with these. Approved but Not Released until conditions are met. Albert. From:Albert Shields Sent: Monday, November 07, 2016 2:28 PM To: 'chad@richduncanconstruction.com' <chad@richduncanconstruction.com> Subject: MST2016-00450, -00451, -00452, -00452, -00454 Hall Pointe Townhomes Chad, same story with these townhomes. Approved but Not Released until conditions are met. Albert. From:Albert Shields Sent: Monday, November 07, 2016 10:48 AM To: 'chad@richduncanconstruction.com'<chad@richduncanconstruction.com> Subject: BUP2016-00318 Hall Pointe Townhomes Chad, same story with BUP2016-00318 except conditions 26 and 27 need to be Met also. Albert Shields From:Albert Shields Sent: Monday, November 07, 2016 10:32 AM To: 'chad@richduncanconstruction.com'<chad@irichduncanconstruction.com> Subject: SIT2016-00022 Hall Pointe Townhomes Chad, in reviewing the application for SiT2016-00022 we find that multiple Conditions of Approval remain Not Met that are required to be met before the site permit can be issued. Those conditions are highlighted on the attached list of the conditions. Accordingly, Plan Review will proceed but permit issuance will be put on hold as Approved but Not Released until the requisite conditions have been met. Please let me know if you have any questions. Albert Shields 1 City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 8723 SW SPRUCE ST, TIGARD, OR, 97223 September 21 , 2018 at 9:23:12 AM Record Type: Record ID: Residential - Master Permit MST2016-00466 Inspection Type: Inspector: 699 Mechanical final Aaron Cillo-Gobel Result: PASS Comments: Violation Summary: Inspector Contractor City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 8723 SW SPRUCE ST, TIGARD, OR, 97223 October 30, 2018 at 11 :41 :33 AM Record Type: Record ID: Residential - Master Permit MST2016-00466 Inspection Type: Inspector: 299 Final inspection Aaron Cillo-Gobel Result: PASS - CofO Comments: Final erosion control passed Street tree certificate received Moisture content form received High efficiency lighting form received C of 0 left on counter. Violation Summary: Inspector Contractor