Loading...
Permit (42) CITY OF TIGARD MASTER PERMIT N.. ' COMMUNITY DEVELOPMENT 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Permit#: MST2016-00452 GARD Date Issued: 08/03/2017 Parcel: 1 S 135AD03400 Site address: 8737 SW SPRUCE ST Jurisdiction: Tigard Subdivision: 1990-053 PARTITION PLAT Project: Hall Pointe Townhomes Lot: 2 Project Description: Building B-New SFA BUILDING Floor Areas Stories: 2 Bedrooms: 2 Reauirecks Re`— First: 590 sf Basement: 0 Height 28 Bathrooms: 3 sf Left: 0 Parking Spaces: 0 Second: 600 sf Garage: 0 sf Front: 0 Dwelling Units: 1 Third: 0 sf Smoke Right: 0 Detectors: Yes Total: 1190 sf Value: $138,249.26 Rear 0 PLUMBING Sinks: 1 Water losets: 3 Washing Mach: 1 Laundry Trays: 0 Lavatories: 4 Dishwashers: 1 Rain Drain: 1 Floor Drains: 0 Sewer Lines: 100 Urinals: 0 Tubs/Showers: 2 Garbage Disp: 1 SF Rain Storm Sewer: 100 Water Heaters: 1 Water Lines: 100 Drains: 0 Footing Drain: 0 Ice Maker: 1 Catch Basins: 0 Hose Bib: 0 Backwater Value: 1 Bckflw Prevntr: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Tvpes Air Conditioning: N Vent Fans: 4 Clothes Dryers: 1 Natural Gas Heat Pump: Y Furn<100K: 0 Hoods: 1 Other Units: 0 Vents: 0 Woodstoves: 0 Furn>=100K: 0 Gas Outlets; 4 ELECTRICAL Residential Unit Serv------ice eeder F-- _ _ Tema Srvc/Feeders Branch 1000 sf or less: 1 0-200 amp: 0 Ea add'I 500 sf: 1 0-200 amp: 0 W/Svc or Fdr: 0 201-400 amp: 0 201-400 amp: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 W/O Svc/Fdr: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Other: N Vaccuum System' N Garage Opener N Other Description: All Ecompasing: Y BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SFA Owner: R-3 1190 Contractor: RICH DUNCAN CONSTRUCTION INC Required Items and Reports(Conditions) 2295 RURAL AVE SE 1 Ersn Cntrl 503-639-4175 SALEM,OR 97302 PHONE: PHONE: 503-390-4999 FAX: Total Fees: $20,460.44 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 952-001-0010 through OAR 9 -001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: � L.... M.ILA' -dieJt Permittee Signature: –,...././ k. &c..-e Oil Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. / Approved plans are required on the job site at the time of each inspection. I Building Permit Applicata 4--,Residential d' n' , it ' 10R OI I ICE I SF ON Ll City of Tigard Received • • 13125 SW Hall Blvd.,Tigard,OR 972/11 � 0 7016 Date/By: // �,�(Fi t:.4,.. Permit Ny!�5� � �t�s� Phone: 503.718.2439 Fax: 503.598 1960 Plan Revie Z 111 ARD Phone:5 Line: 503.639.4175 9 = '- Dare/By: ZLj J7 Other Perm / o r'Z ' '�. � � �? ; �,,, a*o� Date Read/B ������ � J Internet: Line:g 03.639.41 Ready/By: 0 . . Juns: I S See Page 2 for 1 k, Notified/Method: d / 4.4„, ��. 1 P 11 , 71 1 y " i r k �Jy Supplemental Information 7 6/ / (4, �1F-,6*( -v/ TYPE OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING ®New construction 0 Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ❑Addition/alteration/replacement 0 Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. ►5 1-and 2-family dwelling Valuation: I ' .7.134;11534406-9 $ ❑Commercial/industrial --}►J 13/_!t 0.04 4 0 4 ❑Accessory building ❑Multi-family Number of bedrooms: 2 1 3 81 7a J9.C) ❑Master builder 0 Other: Number of bathrooms: 12`5 '2 I O JOB SITE INFORMATION AND LOCATION Total number of floors: 2 -J Job site address: SW Spruce St 77 37 New dwelling area: 1190 square City/State/ZIP:Tigard, R 97223 feet Garage/carport area: square feet Suite/bldg./apt.no.: ` i Project name:Hall Pointe Townhomes Cross street/directions to job site:SW Spruce St and Hall Blvd Covered porch area: 17 square feet QQ Deck area: 91 square feet S'90 Other str re area" //0 square feet Subdivision: REQUIRED DATA:COMMERCIAL-USE CHECKLIST Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. 190 sq ft story townhouse built to Oregon Residential Specialty Code,2014 ed Valuation: $ Existing building area: square feet New building area: square feet El PROPERTY OWNER 0 TENANT Number of stories: Name:E&V Devlopment,LLC Address: 10879 SW 89th Ave Type of construction: City/State/ZIP:Tigard,OR 97223 Occupancy groups: Phone:(503)246-5862 Existing: Fax:(N/A) ® APPLICANT New: ® CONTACT PERSON BUILDING PERMIT FEES* Business name:Rich Duncan Construction (Please Wet tofee scheda/e� Structural plan review fee(or deposit): Contact name:Chad Elliott 503-910-0897 Address: 2295 Rural Ave SE FLS plan review fee(if applicable): City/State/ZIP:Salem,OR 97032 Total fees due upon application: Phone:(503)390-4999 I Fax::(503)390-3633 Amount received: E-mail:Chad@richduncaneonstruction.com PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* CONTRACTOR Commercial and residential prescriptive installation of roof-top mounted Photo Voltaic Solar Panel System. Submit two(2)sets of roof plan with connection details Business name:Rich Duncan Construction Address:2295 Rural Ave SE and fire department access,along with the 2010 Oregon Solar Installation Specialty Code checklist. City/State/ZIP:Salem,OR 97032 Permit Fee(includes plan review Phone:(503)4 3j-t{ /� ( and administrative fees): $180.00 i 99-3633 4111/CB lic.:158330 State surcharge(12%of permit fee): $21.60 Total fee due upon application: $201.60 Authorized signature: This permit application expires if a permit is not obtained r^ * Print name:CHAD-ELL-Kr} 'y�C within 180 days after it has been accepted as complete. Date:10/13/16 Fee methodology set by Tri-County Building Industry Service Board. I:1BuildinglPermits1BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) , Mechanical Permit Appli o ,- � , 4 Mk(lwrl( l: I sl, ()NIA City of Tigardg'';1.4-,,::.) `, --r„ ` Received �/ IN 41Date/By: Permit No,//f7p0/ _, 75 13125 SW Hall Blvd.,Tigard,OR 97223 G� CgJ7 ■ Phone: 503.718.2439 Fax: 503.598 I,964- 016 Date/By:Plan iew 1 1 G n 1.i:> Inspection Line: 503.639.4175 -!�- Other Permit: Internet: Line:gard-or.gov Date Ready/By: Juris: I See Page 2 for Notified/Method: Supplemental Information TYPlith ill i S I 0 N COMMERCIAL FEE* SCHEDULE — USE CHECKLIST Mechanical permit fees*are based on the value of the work ®New construction 0 Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all 0 Demolition 0 Other: mechanical materials,equipment,labor,overhead,and profit. CATEGORY OF CONSTRUCTION Value:$ 1-and 2-family dwelling 0 Commercial/industrialRESIDENTIAL EQUIPMENT/SYSTEMS FEES* 0 Accessory building For special information use checklist. ❑Multi-family 0 Master builder 0 Other: Description Qty. Ea. Total JOB SITE INFORMATION AND LOCATION Heating/cooling: Job site address: SW Spruce St ,, Q7 Air conditioning 46.75 v 7 Furnace 100,00(1 BTU(ducts/vents) 46.75 City/State/ZIP:Tigard,OR 97223 Furnace 100,000+BTU(ducts/vents) 54.91 Suite/bldg./apt.no.: Project name:Hall Pointe Townhomes Heat pump 61.06 Duct work 23.32 Cross street/directions to job site:SW Spruce St&Hall Blvd Hydronic hot water system 23.32 Residential boiler(radiator or hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Subdivision: l Lot no.: Other: 23.32 Other fuel appliances: Tax map/parcel no.: Water heater 23.32 DESCRIPTION OF WORK Gas fireplace/insert 1 33.39 installation of 4 remote heads for a"mini-split"system,misc sheet metal vents Flue vent for water heater or gas fireplace _ 23.32 Or microwave unit,dryer,and bath exhausts Log lighter(gas) 23.32 Wood/pellet stove 33.39 Wood fireplace/insert 23.32 Chimney/liner/flue/vent 23.32 e? PROPERTY OWNER ® TENANT Other: 23.32 Environmental exhaust and ventilation: Name:E&V Development<LLC Range hood/other kitchen Address:10879 SW 89th Ave equipment 33.39 Clothes dryer exhaust 33.39 City/State/ZIP:Tigard,OR 97223 Single-duct exhaust(bathrooms, toilet compartments,utility rooms) 23.32 Phone:(503)246-5862 Fax:(N/A) Attic/crawlspace fans 23.32 I APPLICANT ® CONTACT PERSON Other: 23.32 Business name:Rich Duncan Construction,LLC Fuel piping: $14.15 for first four;$4.03 for each additional Contact name:Chad Elliott 503-910-0897 Furnace,etc. Address:2295 Rural Ave SE Gas heat pump Wall/suspended/unit heater City/State/ZIP:Salem,OR Water heater Phone:(503)390-4999 Fax::(503)390-3633 Fireplace E-mail:chad@richduncanconstruction.comRich Range Barbecue CONTRACTOR Clothes dryer(gas) Busint Other: Advanced Mechanical Services MECHANICAL PERMIT FEES* Addre; PO Box 1699 Subtotal City/S McMinnville, OR 97128 Phone: 503-434-8544 Minimum permit fee($90.00) one CCB: 194814 Plan review(25%of permit fee) State surcharge(12%of permit fee) CCB 11... TOTAL PERMIT FEE This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Authorized signature: _ Fee methodology set by Tri-County Building Industry Service Board _ 41/10 Print name:CHAD 01 Date:10/13/16 J I:1Building\Pennits\MEC_PermitApp_040113_doe 440-46t7T(1 1/02/COM/WEB) , . . , , RECFSVED .. Electrical Permit Arolication 1 01; uf IA( I I S1 (I\1 '1 City of Tigard AUG 2 ?In? Received Dtdc113 : rIZIENSIXIMM . 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review 11 B Phone; 503.718.2439 Fax 503.tfirry 5-11 ti'..rP 4 GARD D., „ : Related Permit 1: 1,3 s 1 1 Inspection Line: 503.6394175 Ready Date/By: km: 0 See Page 1 for AKI) - Internet: www.tigard-or.gov ',131i114.Qrsi..;nrosit)N Noedldethod; Supplemental information M.1...."V-:- ..414:2*---- -M3441,140.0$44,VOIAM":Mningter,111/4-7"-i-MINA MINEPWSLIZIT-attlitW.W.W. 04-St41.6 Ell illi New construction 0 Addition/alteration/replacement Please check an that apply(submit l sets of plans w/items checked): 0 Service or feeder 400 amps or more 0 Building over three stories. D Demolition 0 Other: where the available fault current 0 Marinas and boatyards. F.S.-MINEVIEWSIMAIWWW00.01#000)11ageBRIOMAM exceeds MOM amps at 150 volts or Cr FlOation buildings. 0 I.and 2-family dwelling 0 Commercial/industrial 0 Accessory building less to ground.or exceeds 14.000 0 Commercial-use agricehural amps for all other installations. buildings. 5 Multi-family 0 Master builder 0 Other: ()Fire pump. 0 Installation of 150 KVA or itaiN4eirkea,01/.10**HiltititiWigt-r.7");100-4WASIOW.SITA 0ErnmencY system. larger separately derived ' 0 Addition of new motor load of system. Job#: Job site address. W Spruce St 100HP or more. City/State/ZIP:Tigard,OR 97223 1737 units. _ . 0 occupancy. Recreational vehicle parks. Suite/bldg./apt.#: ,6? Project name: Hall Pointe Townhomes 0 Hazardous locations. El Supply voltage for more than 0 Service or feeder 600 amps Of more. 600 volts nominal. Crossstreet/directions to job site: Hall Blvd&SVV Spruce St Wittiele-VMS001;::...:7.'-.7 7 :ftViVigiOha; Discoed's I no. i nub I Total I • New residential single-or multi-family dwelling thuds Subdivision: Lot#: Includes attached garage. ' 1,000 sq.ft or less I 16834 ji,g.stt 4 Tax map/parcel#: 1S135AD03500 . , . Ea.add'I 500q.R.or portion I 33.92 . 1 tift4b4.''-.Z-F-0.*A-401:•M•jr7r1777.7!•!--..: lag e:!1•.:•1010alraWASOW:ZO. , Limited energy,residential 75.00 2 (with above sq.R.) Limited mere,multi-family 75.00 2 residential(svith above sq.ft.) katiM43.0113MBIMiiiilaeall'ataiMPOSraUROIMMESIN ServicesorfEenedeeers.installation,a IpteroSetlion,Paatior relocation Name: 200 amps or less 1 100.70 100:70 2 Address: 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP: 601 amps to 1,000 amps 301,04 2, Phone:( ) Fax ( ) Over 1,000 amps or volts , 552.26 2 Temporary services or feeders installation,alteration,and/or Email: relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 I intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 ., 2 Owner signature: Date: ,401 amps to 599 amps 168.54 2 '0.41:02:ftfrObilaittilingiargatilleAtittAtt*ERSNRSESS ABraFea:hforc ire nits h;rncehwts,:ration,or-eXtension,per panel , Business name: E&V Development above service or feeder fee, 742 2 each branch circuit : , Contact name: Dr.Gene Davis B.Fee for branch circuits without . service or feeder fee,first • Address: 10875 SW 89th Ave branch circuit 56.18 2 . City/State/ZIP: Tigard,OR 97223 Each add'I branch circuit 7.42 2 : Miscellaneous(service or feeder not included) , Phone:(503)887-9966 Fax::( ) Each manufactured or modular 67.84 2 dwelling,service and/or feeder Email: fmt.india@yahoo.com Reconnect only , s 67.84 2 'afratelilanaNatill*:70111WOOTAI-MIMPANRONSVONSW Pump or irrigation circle 67.84 2 Business name: ProTeeh Power Sign or outline lighting 67.84 2... Signal circuit(s)or limited-energy Address: 17937 MeEwen Rd#200 panel,alteration,or extension. f:l See Page 2 2 Each additional inspection over allowable in any of the above . City/State/ZIP: Portland,OR 97224 . Additional inspection(1 hi min) 66.25/hr Phone:( 503)780-6207 Fax:( ) Investigation(I hr min) 90.00/hr . Email: Industrial plant(1 hr min) 78.18/hr Inspections for which no fee is 90.00/hr CCB Lic.: 198878 Electrical L' .: C916 sprv.Lice: 6125S NESAA-4010iitatIORMO:4100.................................. Suprv.Electrician signature,required: Subtotal: 3 ),I t, Print name: Andrew Anderson Da : 8/2/2017 CI Plan Review Required(25%of permit fee): State surcharge(12%of permit fee): Authorized signature: TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within 180 Print name: Date: days after it has been accepted as complete. * Nuinbcr of inspections allowed per permit. • 1.1fluoldinglPerminiELC_ParaitApp ELR_ERE.doc Rev 06/17/2015 4404615T(1110SICOMMEB Plumbing Permit pp A h Building Fixtures I Jr,t-, ' ,I FOR 0111('1. USE 0A'E1 City of Tigard y Received 4 It 13125 S W Hall Blvd.,Tigard,(I T 1273 8 2016 Date/By: Permit NWSI /6,19p yS..) • Phone: 503.718.2439 Fax: 503.598.1960 Plan Review T I G A 1Z U Inspection Line: 503.639 47 't Date/By: Other Permit No.: Internet: Line:gard-or..4 1 2 e' h r 3 Date Ready/By: Juris: ® See Page 2 for NotiiedJMethod: TY- d Supplemental Information FEE* SCHEDULE ®New construction 0 Demolition For special information use checklist 0 Addition/alteration/replacementDescription Qty. Ea Total 0 Other: New 1-2-family dwellings(includes 100 ft.for each utility connection) CATEGORY OF CONSTRUCTION SFR(1)bath 312.70 ® 1-and 2-family dwelling ❑Commercial/industrial SFR(2)bath 437.78 ❑Accessory building 0 Multi-family SFR(3)bath 500.32 Each additional bath/kitchen 25.02 ❑Master builder 0 Other: JOB SITE INFORMATION AND LOCATION Fire utisprlities:ties:nkler( sq.ft.) Page 2 Site utilities: Job site address: SW Spruce St Z1 27 18,76 87Catch basin or area drain I ✓/ City/State/ZIP:Tigard,OR 97223 Drywell,leach line,or trench drain 18.76 Suite/bldg./apt.no.: l Project name:Hall Point Townhomes Footing drain(no.linear ft.: ) Page 2 Cross street/directions to job site:SW Spruce St and Hall Blvd Manufactured home utilities 50.03 Manholes 18.76 Rain drain connector 18.76 Sanitary sewer(no.linear ft.: ) Page 2 Storm sewer(no.linear ft.:_) Page 2 Subdivision: Water service(no.linear ft.: ) Page 2 Lot no.: Fixture or item: Tax map/parcel no.: Backflow preventer 31.27 DESCRIPTION OF WORK Backwater valve 12.51 Gough and finish plumbing for 1190 sf 2 steory townhome with 2 and 1/2 bath, Clothes washer 25.02 laundry,kitchen.Water and sewer on site Dishwasher 25.02 Drinking fountain 25.02 Ejectors/sump 25.02 Ci PROPERTY OWNER 0 TENANT Expansion tank Name: 12.51 Fixture/sewer cap 25.02 E&V Development,LLC Address:10879 89th Ave Floor drain/floor sink/hub 25.02 City/State/ZIP:Tigard,OR 97223 Garbage disposal 25.02 Phone:(503)246-5862 Hose bib 25.02 Fax:(N/A) Ice maker APPLICANT 0 - 12.51 ® CONTACT PERSON Interceptor/grease trap 25.02 Business name:Rich Duncan construction Medical gas(value:$ ) Page 2 Contact name:Chad Elliott 503-910-0897 Primer 12.51 Address:2295 Rural Ave SE Roof drain(commercial) 12.51 City/State/ZIP:Salem,OR 97032 Sink/basin/lavatory 25.02 Solar units(potable water) 62.54 Phone:(503)399-4999 Fax:: (503)390-3633 Tub/shower/shower pan 12.51 E-mail:chad@richduncaneonstruction.com Urinal 25.02 CONTRACTOR Water closet 25.02 B' Water heater 37.52 A York Custom Mechanical Waterpiping/DWV 5629 - C PO Box 21474 Other: 25.02 -- Subtotal OR 97307 Phone: 503-584-1771 subtotal P' • CCB: 203341 Plumbing: PB1481 Minimum permit fee: $72.50 Plan review (25%of permit fee) Authorized signature: - State surcharge(12%of permit fee) � TOTAL PERMIT FEE � LIOTT -' Print name:CH I Date:10/13/16 1 This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. *Fee methodology set by Tri-County Building Industry Service Board. I:\Building\permitslpLMU-permitApp"tloc 10/01/09 440-4616T(10/02/COM/WEB) City of Tigard 111„, . q COMMUNITY DEVELOPMENT DEPARTMENT T l c R D Building Permit Review — Residential Building Permit #: CI_S'i,2-o.,_./ .._.,3.. ed 0 q3 - Site Address: q7 37 Sk.> -?aee...e. ,.771-1"-e-ed-- Project Name: ,1`/ l)ii771kmho C Lot #: (New dwelling=subdivision name;Addition or Alteration=last name of owner) Planning Review Proposal: /Wt,7 Verify site address/suite#exists and actio in permit system. idillt Iver Terrace Neighborhood: No ❑ Yes,See River Terrace Review Addendum Attached Sit Plan Elements: ree(3)copies of site plan to plan must be on 8-1/2"x 11"or 11 x 17"paper ting structures on site � � Oft of new+structare )with finished: Drawn to scale(standard architect or engineer scale) - � mow, .Ai 1,;,, s #14' orth a ow Pi Utility locations(required for new,may apply for additions) ite address,project or subdivision name and lot number pplicant information(name and phone number) cation of wells/septic systems n'sting trees to bei ot dimensions and building setback dimensions protection me suresretained with drip line,and tree j r �" ,14.-1Z P 4 `@ 4 ' ` 4,4,,, 0' eet tree size,type and location R?5 GQQ �y - � r � 1�Street names - �-- #xarii(, toot °111"ii.t ilnes if more 4'141 :. ,(�.�tM ���I lstA •t,� e, G v lam' J j lean Water Services—Service Provider Lett (lot platted prior to 9/10/1995): ,_ S-O.1. •equired: ❑ Yes,applicant was notified No Received: ❑ Yes ❑ No f r. Public Faciliti Improvement(PFI) Permit: Required: Vi Yes,applicant was notified ❑ No Applied For: /Yes ❑ No,stop intake Land Use Case#: die.20/,s-:0::, c— Zoning: ,Mup-Q Required Setbacks: Front Airr4 Rear Side PRequirement: 7 �' Street Side A . l Garage ;.1 V andsca e % >/ Pler/Lof Coverage Maximum: % Side, /42/cn wegf s cl GO 0 0,,v htHeight: Maximum Height Y1Visual Clearance g � Actual Height 623 'i asements ensitive Lands: ❑ Yes No Urban Forestry Plan Type ❑ Conditions "Met"prior to issuance of buildingpermit Notes: (j , / A1r- it i� �� ,max �- //' ��'-� rte' Approved By Planning: r / I� °` Date: / - / —! Revisions (after Building Submittal only) Revision 1: ❑ A roved Reviewer Date 1'P ❑ Not Approved Revision 2: ❑ Approved ❑ Not Approved Revision 3: ❑ Approved 0 Not Approved I:\Building\Forms\B 1dgPermitRvw_RES_091216.docx Building Permit Submittal Original Submittal Date: 711//1//k Site Plans: # 3 Building Plans: # Building Permit#: [a`Enter building permit#above. ermit Coordinator Buildtng Workflow Routing: 't Planning ©' ngineering Workflow Sign-off: Sign-off for Planning(include notes from planning review) Route Application Documents: EThngineering: (1) copy of permit application, (1) site plan, (1)building plan and __original plan review routing form. nig Building: original permit application, site plans,building plans,engineer and beam calculations and trust details,if applicable,etc. Notes: lit...4... Ado / By Permit Technician: (/6/ Date: // `/A, Engineering Review IA Slope at building pad: /X, Londitions"Met"prior to issuance of building permit ❑ Easements (encroachments)per engineering conditions of approval and plat 0 Water Quality/Quantity Facility: Assess Water Quality Fee in-lieu: 0 Yes 0 No Assess Water Quantity Fee in-lieu: 0 Yes 0 No LIDA Facility on lot: 0 Yes 0 No Date: 0 NOT Approved jig ineering: Notes: rdec, rj :JG' iry f Date: f 3 Approved by Engineering: ___________AL____D Revisions (after Building Submittal only) Reviewer Date Revision 1: 0 Approved 0 Not Approved Revision 2: 0 Approved 0 Not Approved Revision 3: 0 Approved 0 Not Approved , Permit Coordinator Review 0 Conditions "Met"prior to issuance of building permit11 - j do„-- ate: /4- 4O '- pproved,NOT Released: ,,,,,, ..e>f Notes: /j"z Revisions (after Building Submittal only) Revision Notice 1: Date Sent to Applicant: Revision Notice 2: Date Sent to Applicant: Revision Notice 3: Date Sent to Applicant: SDC Fees Entered: Wash Co Trans Dev Tax: es 0 N/A Tigard Trans SDC: i--.)fes N/A Parks SDC: 'Yes 0 N/A K to Issue Permit? J=C4 ADate: ��Z Approved byPermit Coordinator: I:\Building\Forms\BldgPermitRvw_RES_091216.docx City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 8737 SW SPRUCE ST, TIGARD, OR, 97223 September 21 , 2018 at 9:48:39 AM Record Type: Record ID: Residential - Master Permit MST2016-00452 Inspection Type: Inspector: 699 Mechanical final Aaron Cillo-Gobel Result: PASS Comments: Violation Summary: Inspector Contractor City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 8737 SW SPRUCE ST, TIGARD, OR, 97223 September 27, 2018 at 10:59:15 AM Record Type: Record ID: Residential - Master Permit MST2016-00452 Inspection Type: Inspector: 199 Electrical final Chip Barnett Result: PASS Comments: Violation Summary: Inspector Contractor City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 8737 SW SPRUCE ST, TIGARD, OR, 97223 October 30, 2018 at 11 :44:15 AM Record Type: Record ID: Residential - Master Permit MST2016-00452 Inspection Type: Inspector: 299 Final inspection Aaron Cillo-Gobel Result: PASS - CofO Comments: Final erosion control passed Street tree certificate received Moisture content form received High efficiency lighting form received C of 0 left on counter. Violation Summary: Inspector Contractor