Loading...
Permit (36) CITY OF TIGARD MASTER PERMIT RPermit#: MST2016 00456 II.: ' COMMUNITY DEVELOPMENT Date Issued: 08/03/2017 -F[ AR D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 1S135AD03400 Jurisdiction: Tigard Site address: 8775 SW SPRUCE ST Subdivision: 1990-053 PARTITION PLAT Lot: 2 Project: Hall Pointe Townhomes Project Description: Building A-New SFA BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 2 First: 590 sf Basement: sf Left: Parking Spaces: Height: 28 Bathrooms: 3 Second: 600 sf Garage: sf Front: Smoke Yes Dwelling Units: 1 Third: sf Right: Detectors: Total: 1190 sf Value: $138,249.26 Rear: PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 4 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Drains: 0 Tubs/Showers: 2 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 0 Backwater Value: 1 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 4 Clothes Dryers: 1 Natural Gas Heat Pump: Y Hoods: 1 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 4 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add!500 sf: 1 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: Y BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SFA VB R-3 1190 Owner: Contractor: DAVIS,EUGENE REVOCABLE LIVING T RICH DUNCAN CONSTRUCTION INC Required Items and Reports(Conditions) 10875 SW 89TH AVE 2295 RURAL AVE SE 1 Ersn Cntrl 503-639-4175 TIGARD,OR 97223 SALEM,OR 97302 PHONE: 503-246-5862 PHONE: 503-390-4999 FAX: Total Fees: $20,460.44 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-0 1-0090. You may obtain a copy of the rule or direct questions to OUNC by calling 503.232.19872. or 1.800.332.2344. Issued By: 4I Permittee Signature: Srt. �L�✓/`�u�0� `/ Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Applic ' „,- - -, Residential � KFOR OF I( E 1 SE ONE1 City of Tigard -Received ��Q/�, Permit No.:Ml T 5 Date/By /I Up J l��� et r 5 111 .., 13125 SW Hall Blvd.,Tigard,OR" ?223 Plan Review ■ Phone: 503.718.2439 Fax: 503.598.1960 Dare/By: -a6- I) Other Permit:51.4)e010t6,-e6 377 r 1 G A R'tl Inspection Line: 503.639.417 . ini r AD Date ReadyBy:� H See Page 2 for Juris Internet: www.tigard-or.gov Notified/Method• �/' rg' Supplemental Information T14L'NG IV ,,IO '' k-1/1 it- 57&--A /v7 TYPE OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING ®New construction 0 Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ❑Addition/alteration/replacement 0 Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. Valuation: $1;053+00 �� 4 1-and 2-family dwelling 0 Commercial/industrial . ❑Accessory building 0 Multi-family Number of be ooms: 2 J 3 g'4,9 9 4 ❑Master builder 0 Other: Number of bathrooms: X2`S„3 JOB SITE INFORMATION AND LOCATION Total number of floors: 2 Job site address: SW Spruce St B-r-,J New dwelling area: 1190 square feet City/State/ZIP:Tigard,OR 97223 Garage/carport area: square feet Suite/bldg./apt.no.: /— Project name:Hall Pointe Townhomes Covered porch area: 17 square feet 6 6 0 Cross street/directions to job site:SW Spruce St and Hall Blvd Deck area: 91 square feet v 9 0 Other trite ure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. •190 sq ft 2 story townhouse built to Oregon Residential Specialty Code,2014 ed Valuation: $ Existing building area: square feet New building area: square feet rgi PROPERTY OWNER 0 TENANT Number of stories: Name:E&V Devlopment,LLC Type of construction: Address:10879 SW 89th Ave Occupancy groups: City/State/ZIP:Tigard,OR 97223 Existing: Phone:(503)246-5862 Fax:(N/A) New: ® APPLICANT ® CONTACT PERSON BUILDING PERMIT FEES* (Please refer to fee schedule) Business name:Rich Duncan Construction Structural plan review fee(or deposit): Contact name:Chad Elliott 503-910-0897 FLS plan review fee(if applicable): Address: 2295 Rural Ave SE —` Total fees due upon application: City/State/ZIP:Salem,OR 97032 �( p Amount received: l (p 3`. ,y0 Phone:(503)390-4999 Fax::(503)390-3633 E-mail:chad@richduncanconstruction.com PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* Commercial and residential prescriptive installation of CONTRACTOR roof-to, i ounted Photo Voltaic Solar Panel Sys -0 Business name:Rich Duncan Construction Submit two( of roof plan with ••. -coon details � and fire department ac . •• with the 2010 Oregon \kddress:2295 Rural Ave SE Solar Installation Spe '= y ':'e checklist. City/State/ZIP:Salem,OR 97032 Permit F includes plan rInli $180.00 and administrative fees 71 Phone:(503)4439 3 p- 141 019 Fax:(503)399-3633 State surcharge(12%of permit fee): $21.60 CB lie.:158330Total fee due upon application: $201.60 Authorized signature: This permit application expires if a permit is not obtained r within 180 days after it has been accepted as complete. Print name:CHAD ELLI 1 TT Date:10/13/1.6 *Fee methodology set by Tri-County Building Industry Service Board. 1:\BuildinglPermits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) 1 r i' ri�"1 1Vlecbanical Permit Aupl _ �1 � 'ji rt)R ole Fit F ttil'.o 1:v City of Tigard Received j�/ DateDate/By: Permit No e.S%cy#6v"Gti�%56 13125 SW Hall Blvd.,Tigard,OR mPlan Review ' Phone: 503.718.2439 Fax: 503.59'8.1960' 1 1 3 DateBy: Other Permit: TIG R Ia Inspection Line: 503.639 4175 ,4 ,,,r 1..„.5r, q 1.1 Date Ready/By: Juris: I Iii See Page 2 for Internet: www.tigard-or.gov q1 1 � t,,.n t.t" II.'s i. Notified/Method: Supplemental Information ,BUiLl "'3 �_ Ttl AS1ON TYPE OF WORK COMMERCIAL FEE* SCHEDULE -USE CHECKLIST Mechanical permit fees*are based on the value of the work ®New construction 0 Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all ❑Demolition 0 Other: mechanical materials,equipment,labor,overhead,and profit. Value:$ CATEGORY OF CONSTRUCTION RESIDENTIAL EQUIPMENT/SYSTEMS FEES* ® 1-and 2-family dwelling 0 Commercial/industrial 0 Accessory building For special information use checklist. ❑Multi-family 0 Master builder 0 Other: Description I Qty. I Ea. I Total JOB SITE INFORMATION AND LOCATION Heating/cooling: Air conditioning 46.75 Job site address: SW Spruce St 8115 Furnace 100,000 BTU(ducts/vents) 46.75 City/State/ZIP:Tigard,OR 97223 Furnace 100,000+BTU(ducts/vents) 54.91 Heat pump / 61.06 Suite/bldg./apt.no.: Project name:Hall Pointe Towuhomes Duct work 23.32 Cross street/directions to job site:SW Spruce St&Hall Blvd Hydronic hot water system 23.32 Residential boiler(radiator or hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Subdivision: Lot no.: Other: 23.32 Other fuel appliances: Tax map/parcel no.: Water heater _ 23.32 DESCRIPTION OF WORK Gas fireplace/insert 33.39 Flue vent for water heater or gas installation of 4 remote heads for a"mini-split"system,misc sheet metal vents fireplace 23.32 ek_ microwave unit,dryer,and bath exhausts Log lighter(gas) 23.32 Wood/pellet stove 33.39 Wood fireplace/insert 23.32 Chimney/liner/flue/vent 23.32 Other: 23.32 0 PROPERTY OWNER 0 TENANT Environmental exhaust and ventilation: Name:E&V Development<LLC Range hood/other kitchen equipment 33.39 Address:10879 SW 89th Ave Clothes dryer exhaust 33.39 City/State/ZIP:Tigard,OR 97223 Single-duct exhaust(bathrooms, toilet compartments,utility rooms) 23.32 Phone:(503)246-5862 Fax:(N/A) Attic/crawlspace fans 23.32 l** APPLICANT 0 CONTACT PERSON Other: 23.32 Fuel piping: Business name:Rich Duncan Construction,LLC $14.15 for first four;$4.03 for each additional Contact name:Chad Elliott 503-910-0897 Furnace,etc. _ Address:2295 Rural Ave SE Gas heat pump Wall/suspendedlunit heater City/State/ZIP:Salem,OR Water heater Phone:(503)390-4999 Fax::(503)390-3633 Fireplace Range E-mail:shad@richduncanconstruction.comRich Barbecue CONTRACTOR Clothes dryer(gas) Business Other: Advanced Mechanical Services — MECHANICAL PERMIT FEES* Address Subtotal PO Box 1699 Minimum permit fee($90.00) City/Sta McMinnville, OR 97128 Phone: 503-434-8544 — Plan review(25%of permit fee) 4,-i-e:- ( CCB: 194814 — State surcharge(12%of permit fee) - CCB lic.. _ TOTAL PERMIT FEE l This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Authorized signature: (.c__�J * Fee methodology set by Tri-County Building Industry Service Board Print name:CHAD ELLO / Date:10/13/16 I:\Building\Permits\MEC_PermitApp_040113.doc 440-4617T(11/02/COM/WEB) , ., . 'RECEIVED Electrical Permit Anolication 1 ()12(H ll(l- I SI-I(1J \ City of Tigard ' G 1017 Receivedf Datc/B : Pemit it f .4 /C `)y— , !e o 13125 SW Hall Blvd.,Tigard,OR 9772 TPlan Review Phone; 503.718.2439 Fax: 503.5 OFIG Da Related Permit k: Inspection Line: 503.639.41758 yNG �,,i Ready Date/By: Jurs: 0 See Page 2 for I I t_;,�l.! Internet. ativw.tigard-or.gov �pU jii. .� i • Notified/Method: Supplemental Information .. "':I, :'--"moi"_. .;1,r" ;... - - ..k. � J.S s;+=`.?%iT:=`;i,'::s=3[.,�:,�`-*,,a,.�'. %..-Y„-.`ter- t=*•,�-. '" ,"'`y pi.rc^:�•'..='t ;,.�.:.• _��.y �-.cam>'�� "p��p� .x,:-..! .�;= �.,�::,"•%�% �.�s- �"u:��:� s`u '�- moi r..�"-r-:..:. -.� `'��:. ...m;?x,...R��,.s� ,.:t✓'3�33��..a +:._'��TJ�X .;:ut�.- •__-. f._.r�`�.. �-x:.� r�{��: :!�.•�>�.r""N����:_,.,..��:.�'s=.,y�> .�:.;....:r•.r es New construction 0 Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w/items checked): 0 Service or feeder 400 amps or more 0 Building over three stories. 0 Demolition 0 Other: where the available fault current 0 Marinas and boatyards. x'xx� ��.vf�����sem;;.� �.`i�= ":�"' =�'�"�:�.x"_.-��•. '>�.-_��`•U� exceeds 10.000 amps at 150 volts or 0 Floating buildings. �:net.�:.:=.a.�a�....._..;-��:...x6,�x..:.,%;;3�, ,.�t•.,..,,.,..-:M:4:•��N,�F.f6R!0•J�.�.rsi_K='�:.;f.•„�-��'S:.-..%.';...u.:a2��;:,��7,��:�-`.tea, ❑i•and 2-family dwelling 0 Commercial/industrial 0 Accessory building less to ground,or exceeds 14.000 0 Commercial-use agricultural amps for all other installations. buildings. 5 Multi-family 0 Master builder 0 Other: D Fire pump. D Installation of 150 KVA or '~ "<< - x "+ ogre k% ^? C3,-,Einerg ency system. larger separately derived Addition of new motor load of system. Job#: Job site address:041SW Spruce St I00HP or more. 0 Six or more residential units. occupancy. City/State/ZIP:Tigard,OR 97223 0 Recreational vehicle parts. ❑Health-care facilities. Suite/bldg./apt.#: A- Project name: Hall Pointe Townhomes ['Hazardous locations. 0 Supply voltage for more than 0 Service or feeder 600 amps or more. 600 volts nominal. Cross street/directions to job site: Hall Blvd&SW Spruce St MWR" '_"' "' naeeipdea I Ow. I Ems 1 Total New residential single-or multi-family dwelling unit Subdivision: Lot#: Includes attached garage. 1,000 sq.ft.or less I 168.54 /14'Sif 4 Tax ma arcel#: 1S135AD0350ti �' ��j.�'�, ��`�� _,,�s' _ �` - �_ Es.add't S00 sq.ft.or portion 1 33.92 33',17. I > ,. `':s•s : ,.,�,:r . ..:.�;,:.. 1; :'t rf,._'!�€=r; -. 5 r ial l �. E# '., r__s M ............ _, Limited errergy,residents :_...,,...... (with above sq.ft.) 75.00 2 Limited energy,multi-family 75.00 2 residential(with above sq.ft.) :-;.F�Y�� r�:�yisyf >Y�y�„+^='Y'- �:��f',=`,��,..� ��r��,����� Rcaewablc Energy D See Page 2 :;r:'„^w's:c Jr�n7t: ':Jw* s+;t:•x�'-�:r%fr rrc x^ '-x.., r=:e'eat:; --�-'::=,..=F<...._.-_...,.. Services or seeders iasbtlation,alteration,and/or relocation Name: 200 amps or less l 100.70 100•-x 2 Address: 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP: 601 amps to 1,000 amps 301.04 2 Phone:( ) Fax;( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email: relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 I intended for sale,lease,rent,or exchange.according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: 4099 amps � i 2 ,„ c .aYWSWAteR�.. ;ZrEfi,yTS• Rtl.;." �:�ttA: 4 ?-` TM B711, bnrnh—nwsawtteaon,or esens n,pepanel Business name: E&V Development above service or feeder fee, 7.42 2 each branch circuit Contact name: Dr.Gene Davis B.Fee for branch circuits without Address: 10875 SW 89tb Ave service or feeder fee,first 56.18 2 branch circuit • City/State/ZIP: Tigard,OR 97223 Each add'l branch circuit 7.42 2 • Miscellaneous(service or feeder not included) • Phone:(503)887-9966 Fax::( ) Each manufactured or modular 67.84 2 Email: fmtindia@yahoo.com dwelling,service and/or feeder • �Y Reconnect only 67.84 2 ti'teain+srq,ti .tA1+ 00�! . . K _ ... Pum or irrigationccircle 67.84 2 Business name: ProTech Power Sign or outline lighting 67.84 2 Address: 17937 McEwen Rd#200 Signale. Ier circuit(s)oor limited-energy 0 See Page 2 2 panel.alteration,or extension. City/State/ZIP: Portland,OR 97224 Each additional inspection over allowable in any of the above Additional inspection(1 hr nun) 66.25/hr Phone:( 503)780-6207 Fax:( ) Investigation(1 hr rein) 90.00/hr Email' Industrial plant(1 hr min) 78.18/hr Inspections for which no fee is 90.00/hr t ifncall listed Yr hr mm CCB Lic.: 198878 Electrical L. .: C916 uprv.Li • 6125Se eY ( ) ..0 otal y Ysx.,,:_M'::%r:.+.:.::.•.>v".':;'ti.. ............ .. ' ........� ��i"Yrs v"::�%-:...t_ Suprv.Electrician signature,required: Subtotal: 303•/4 Print name: Andrew Anderson Da : 8/2/2017 ci Plan Review Required(25%of permit fee): State surcharge(12%of permit fee): Authorized signature: TOTAL PERMIT FEE: Ibis permit application expires if a permit is not obtained within 180 Print name: Date' days after it has been accepted as complete. * Number of inspections allowed per permit. I.'BwldinglPermeelELC PermitApp EI.R_ERE.doe Rev 06117t2015 440-4615T01105/COM/WEB ' Pittmbing Permit A01314tis� Building Fixtures FOR Of FR l 1st: oyLv City of Tigard OCT 1 8 2 016 Received 13125 SW Hall Blvd.,Tigarda OR 97223 14 2 Date/13y: Permit NoM$, / ..ver.5 Phone: 503.718.2439 F q + a Plan Review ia9 6416 . .f Date/By: Other Permit No.: • TI G A R D� Inspection Line: 503.639 4 i pi r t,/1 t � Date Ready/By: Juris: H See Page 2 for Internet: Line: gard-or. r s.71"i I 1',,i O i Notified/Method: Supplemental Information TYPE OF WORK FEE* SCHEDULE ®New construction 0 Demolition For special information use checklist Description I Qty. I Ea. I Total 0 Addition/alteration/replacement 0 Other: New 1-2-family dwellings(includes 100 ft.for each utility connection) CATEGORY OF CONSTRUCTION SFR(1)bath 312.70 ►14 1-and 2-family dwelling 0 Commercial/industrial SFR(2)bath 437.78 ❑Accessory building 0 Multi-family SFR(3)bath 500.32 ❑Master builderEach additional bath/kitchen 25.02 0 Other: Fire sprinkler( sq.ft.) Page 2 JOB SITE INFORMATION AND LOCATION Site utilities: Job site address: SW Spruce St Catch basin or area drain 18.76 City/State/ZIP:Tigard,OR 97223 Drywell,leach line,or trench drain 18.76 Footing drain(no.linear ft.: ) Page 2 Suite/bldg./apt.no.: Project name:Hall Point Townhomes Manufactured home utilities 50.03 Cross street/directions to job site:SW Spruce St and Hall Blvd Manholes 18.76 - Rain drain connector 18.76 Sanitary sewer(no.linear ft.: ) Page 2 Storm sewer(no.linear ft.:_) Page 2 Water service(no.linear ft.: ) Page 2 Subdivision: Lot no.: Fixture or item: Tax map/parcel no.: - Backflow preventer 31.27 DESCRIPTION OF WORK Backwater valve 12.51 •ouh and finish plumbing for 1190 sf 2 steory townhome with 2 and 1/2 bath, Clothes washer 25.02 Dishwasher 25.02 laundry,kitchen.Water and sewer on site Drinking fountain 2:5.02 Ejectors/sump 25.02 ►.:� PROPERTY OWNER 0 TENANT Expansion tank 12.51 Name:E&V Development,LLC Fixture/sewer cap 25.02 Address:10879 89th Ave Floor drain/floor sink/hub 25.02 Garbage disposal 25.02 City/State/ZIP:Tigard,OR 97223 Hose bib 25.02 Phone:(503)246-5862 Fax:(N/A) Ice maker 12.51 ® APPLICANT o4 CONTACT PERSON Interceptor/grease trap 25.02 Business name:Rich Duncan construction Medical gas(value:$ ) Page 2 Contact name:Chad Elliott 503-910-0897 Primer 12.51 Roof drain(commercial) 12.51 Address:2295 Rural Ave SE Sink/basin/lavatory 25.02 City/State/ZIP:Salem,OR 97032 Solar units(potable water) 62.54 Phone:(503)399-4999 Fax::(503)390-3633 Tub/shower/shower pan 12.51 E-mail:chad@richduncanconstruction.com Urinal 25.02 CONTRACTOR Water closet 25.02 By •`- ,, , ,� Water heater 37.52 Water piping/DW V 56.29 A, York Custom Mechanical Other: _ 25.02 Ci PO Box 21474 _ Subtotal P1 Keizer, OR 97307 Phone: 503-584-1771 Minimum permit fee: $72.50 CCB: 203341 Plumbing: PB1481 Plan review (25%of permit fee) State surcharge(12%of permit fee) Authorized signature: A"--2._, TOTAL PERMIT FEE Print name:CHAD ELLIOTT Date:10/13/16 This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. *Fee methodology set by Tri-County Building Industry Service Board. I:\Building\Permits\PLMt7-PermitApp.doc 10/01/09 440-4616T(10/02/COM/WEB) City of Tigard COMMUNITY DEVELOPMENT DEPARTMENT III ■ T 1 c A R n Building Permit Review — Residential Building Permit #: /7,5-7,?-0/6 --- off? /s Site Address: '7 75— 8k) — mom. LS/T Project Name: % �`/ PDln71 ` nhoe c Lot #: (New dwelling=subdivision name;Addition or Alteration=last name of owner) Planning Review Proposal: AJet) S# Q/Verify site address/suite#exists and actio in permit system. fiver Terrace Neighborhood: V No ❑ Yes,See River Terrace Review Addendum Attached Sit Plan Elements: I tree(3)copies of site plan td) • ting structures on site o plan must be on 8-1/2"x 11"or 11 x 17"paper I,j t 4t' . ,..,,t of nqw acture(including decks)with Ettlislicd Drawn to scale(standard architect or engineer scale)0 ' ,g"c "-+r' .'e. Orth avow 3 PAT3tihty locations (required for new,may apply for additions) 0 ite address,project or subdivision name and lot number ' 0 cation of wells/septic systems pplicant information(name and phone number) tO 'sting trees to be retained with drip line,and tree l Lot dimensions and building setback dimensions .rotection measures Peot apta pm:►eet tree size,type and location , $ � t• -- ,.;if::,, ::'4 s'.k.:44); 1'I Street names ` � ti( t Orttalut b es l ate 1 .; t4S) e-,.. '12' 1114— ` U to lean Water Services—Service Provider Lett (lot platted prior to 9/10/1995): 'equired: ❑ Yes,applicant was notifiedFr No Received: ❑ Yes ❑ No IG Public Facilaces, Improvement(PFI) Permit: Required: applicant was notified ❑ No Applied For: Yes ❑ No,stop intake Land Use Case#: S)Aed:Q.Lv15-(_2,f. c-- Zoning: MU/2—Q _ V Required Setbacks: Front Am Rear C� Side/s 0 Street Side MA Garage AM. andscape Requirement: .% 51G'1,� ' • ViLot Coverage Maximum: co toes-fr — de BQ Building Height: Maximum Height 4"S Actual Height Q3 1')✓isual Clearance 41 asements 'ensitive Lands: ❑ Yes /No Type Urban Forestry Plan ❑ Conditions "Met"prior to issuance of building permit / Notes: C_17,1 1 ii ' ` /a �' %�_ AonOr 7'L c,-) ,,fi onl%P . .sVf /lYl��i73 if ` / J7r60YI/ > S l_ 4._,,f7 ' Approved By Planning: Date: /O " /8—/4 Revisions (after Building Submittal only) Reviewer Date Revision 1: ❑ Approved ❑ Not Approved Revision 2: ❑ Approved ❑ Not Approved Revision 3: ❑ Approved ❑ Not Approved I:\Building\Forms\BldgPermitRvw REs 091216.docx Building Permit Submittal Original Submittal Date: /©/iI/% Site Plans: # 3 Building Plans: # Building Permit#: EL—Enter building permit#above. Workflow Routing: ®-Planning 0--Engineering [ -15 rmit Coordinatorlfuilding Workflow Sign-off: l Sign-off for Planning(include notes from planning review) Route Application Documents: I:4--Engineering: (1) copy of permit application, (1) site plan, (1) building plan and original plan review routing form. D7Building: original permit application,site plans,building plans,engineer and beam calculations and trust details,if applicable,etc. Notes: By Permit Technician: �- r Date: //// Engineering Review XSlope at building pad: a Conditions "Met" rior to issuance of buildingpermit p ❑ Easements (encroachments)per engineering conditions of approval and plat El Water Quality/Quantity Facility: Assess Water Quality Fee in-lieu: ❑ Yes ❑ No Assess Water Quantity Fee in-lieu: ❑ Yes ❑ No LIDA Facility on lot: ❑ Yes ❑ No ❑ NOT Ap rove by ngineering: Date: Notes: w,e;t > 6 '�' Approved by Engineering: -1) Date: %� Revisions (after Building Submittal only) Reviewer Date Revision 1: ❑ Approved ❑ Not Approved Revision 2: ❑ Approved ❑ Not Approved Revision 3: ❑ Approved El Not Approved Permit Coordinator Review El Conditions "Met"prior to issuance of building permit 2kApproved,NOT Released: Date: i/l ,/ _ - otes: Revisions (after Building Submittal only) Revision Notice 1: Date Sent to Applicant: Revision Notice 2: Date Sent to Applicant: Revision Notice 3: Date Sent to Applicant: SDC Fees Entered: Wash Co Trans Dev Tax: -5/Yes El N/A Tigard Trans SDC: csiYes ❑ N/A Parks SDC: I Yes ❑ N/A i411K to Issue Permit Approved by Permit Coordinator: Date: 9 a R--- 1:\BuildingTonns\BIdgPerinitRvw_RES I:\Building\Fonns\BldgPermitRvw_RES 091216.docx City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 8775 SW SPRUCE ST, TIGARD, OR, 97223 September 21 , 2018 at 11 :21 :32 AM Record Type: Record ID: Residential - Master Permit MST2016-00456 Inspection Type: Inspector: 699 Mechanical final Aaron Cillo-Gobel Result: PASS Comments: Violation Summary: Inspector Contractor City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 8775 SW SPRUCE ST, TIGARD, OR, 97223 October 30, 2018 at 11 :46:58 AM Record Type: Record ID: Residential - Master Permit MST2016-00456 Inspection Type: Inspector: 299 Final inspection Aaron Cillo-Gobel Result: PASS - CofO Comments: Final erosion control passed Street tree certificate received Moisture content form received High efficiency lighting form received C of 0 left on counter. Violation Summary: Inspector Contractor