Report ..f.-eS),..0 1 2 - 1 GL 12(°'-c S , Aic 4 s2- RECEIVED - '*' JUL 6 2017 " " . . . . • wyATBTINOFItt,°` , ' .`' � � TIGARD ' � `: G DIVISION . FIRE PROTECTION, INC. 9095 S.W. Burnham Tigard, OR 97223 VISIONWORKS WASH SQUARE 10104 SW WASHINGTON SQUARE RD TIGARD, OR 97223 : , FIRE PROTECTION EQUIPMENT SUBMITTAL tqcciWorldwide Fire Protection Contacts www.tyco-fire.com Products Series TY-FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage GeneralNOTICE The TYCO Series TY-FRB Sprinklers . •`+ " - Description described herein must be installed and A The TYCO Series TY FRB,5.6 K factor, maintained in compliance with this doc- ument, as well as with the applicable ii Upright(TY313)and Pendent(TY323) standards of the National Fire Protec- ., '' a.s', Sprinklers described in this data sheet tion Association,in addition to the stan- :" ' are quick response,standard coverage, dards of any other authorities having I, decorative 3 mm glass bulb-type spray jurisdiction.Failure to do so may impair sprinklers designed for use in light or the performance of these devices. Y ordinary hazard,commercial occupan- : cies such as banks, hotels,and shop- The owner is responsible for maintain " ping malls. ing their fire protection system and devices in proper operating condition. The recessed version of the Series TY- The installing contractor or sprinkler FRB Pendent Sprinkler,where applica- manufacturer should be contacted with ble, is intended for use in areas with a any questions. , finished ceiling.This recessed pendent sprinkler uses one of the following: • A two-piece Style 15 Recessed Sprinkler Escutcheon with recessed adjust- Identification ment up to 5/8 inch (15,9 mm)from the flush pendent position. Number (SIN) a • A two-piece Style 20 Recessed Escutcheon with recessed adjust- TY313 Upright 5.6K, 1/2:NPT �rr ment up to 1/2 inch (12,7 mm)from TY323 Pendent 5.6K, 1/2"NPT the flush pendent position. The adjustment provided by the Technical Recessed Escutcheon reduces the Temperature Rating accuracy to which the fixed pipe drops Data 135°F(57°C) to the sprinklers must be cut. 155°F(68°C) Intermediate level versions of Series Approvals 175°F(79°C) TY-FRB Sprinklers are described in UL and C-UL Listed 200°F(93°C) Technical Data Sheet TFP357. Sprin- FM, LPCB,and VdS Approved 286°F(141°C) kler guards and shields are described CE Certified Finishes in Technical Data Sheet TFP780. Sprinklers with Polyester Finish are UL Sprinkler:Refer to Table A and C-UL Listed as Corrosion-Resis- Recessed Escutcheon:White Coated, tant Sprinklers. Chrome Plated,or Brass Plated Maximum Working Pressure Physical Characteristics 175 psi(12.1 bar) Frame Bronze 250 psi(17.2 bar)* Button Brass/Copper *The maximum working pressure of 250 psi Sealing Assembly Stainless IMPORTANT (17.2 bar)only applies to the listing by Un- Steel w/TEFLON Always refer to Technical Data derwriters Laboratories,Inc.(UL). Bulb Glass Sheet TFP700 for the "INSTALLER Discharge Coefficient Compression Screw Bronze WARNING"that provides cautions K=5.6 GPM/psi1/2(80,6 LPM/bars/2) Deflector Bronze with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 FEBRUARY 2014 TFP172 TFP172 Page 2 of 4 Components: *Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16"(11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 6* P.7/nigiMA ' /rirr-LiT-I-1-u - \ i 5 ! 7/16" 1 (11,1 mm) I N.1 c q 1 NOMINAL 01 2" - 101 lir MAKE-IN (50,8 mm) ' i 2 I! 0 (50,8 mm) (34,9 mm) I-!1-3/8" I �- - 3 • I� WRENCH 1 t / ! FLATS 1/2"NPT** DEFLECTOR* [.- - 2-7/8"(73,0 mm)DIA. -- CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT(TY313)AND PENDENT(TY323)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE L, Operation Installation The glass bulb contains a fluid which The TYCO Series TY-FRB,5.6 K-factor, WRENCH RECESS expands when exposed to heat.When Upright(TY313)and Pendent(TY323) (USE ONLY the rated temperature is reached, the Sprinklers must be installed in accor- END"A") fluid expands sufficiently to shatter the dance with this section. glass bulb, allowing the sprinkler to FIGURE 2 activate and water to flow. General Instructions Do not install any bulb-type sprinkler if W-TYPE 6 the bulb is cracked or there is a loss SPRINKLER WRENCH Design of liquid from the bulb.With the sprin- kler held horizontally,a small air bub- WRENCH Criteria ble should be present. The diameter RECESS The TYCO Series TY-FRB,5.6 K-factor, of the air bubble is approximately 1/16 inch (1,6 mm)for the 135°F(57°C)and Upright(TY313)and Pendent(TY323) 3/32 inch(2,4 mm)for the 286°F(141°C) ��, Sprinklers are intended for fire protec- temperature ratings. tion systems designed in accordance A leak-tight 1/2 inch NPT sprinklerI /A with the standard installation rules rec- ognized by the applicable Listing or should be obtained by applying a min Approval agency(such as, UL Listing imum to maximum torque of 7 to 14 is based on the requirements of NFPA ft.-lbs. (9,5 to 19,0 Nm). Higher levels dlib t ��' 13, and FM Approval is based on the of torque can distort the sprinkler Inlet PUSH WRENCH requirements of FM's Loss Prevention with consequent leakage or impairment IN TO ENSURE Data Sheets).Only the Style 15 or Style of the sprinkler. ENGAGEMENT 20 Recessed Escutcheon is to be used Do not attempt to compensate for WITH SPRINKLER for recessed pendent installations. insufficient adjustment in the Escutch- WRENCHING AREA eon Plate by under-or over-tightening FIGURE 3 the sprinkler. Re-adjust the position of W-TYPE 7 RECESSED the sprinkler fitting to suit. SPRINKLER WRENCH Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1.Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. TFP172 Page 3 of 4 Step 3.Tighten the sprinkler into the sprinkler fitting using only the W-Type _ 2-7/8" DIA. 6 Sprinkler Wrench(Figure 2).With ref- (73,0 mm) erence to Figure 1,apply the W-Type 6 Sprinkler Wrench to the wrench flats. 2-1/4"DIA. Torque sprinklers 7 to 14 ft.-lbs.(9,5 to FACE OF (57,2 mm) 19,0 Nm). SPRINKLER FITTING Recessed Pendent Sprinklers + \ 5/8"(15,9 mm) ml The Series TY-FRB Recessed Pendent __ FLUSH Sprinklers must be installed in accor- 3/8±5/16 1 fI dance with the following instructions. 1 , ir WNW Step A.After installing the Style 15 or }MOUNTING !i, 1/8" 1 Style 20 Mounting Plate over the sprin- SURFACE mm) J(3,2 1 kler threads, and with pipe-thread ff sealant applied to the pipe threads, CLOSURE SERIES MOUNTING 1-3/8"(34 ,9 mm) hand-tighten the sprinkler into the sprinkler fitting. TY-FRB PLATE 3/4"(19,1 mm) Step B.Tighten the sprinkler into the FIGURE 4 Step B. fitting using in the int the SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) 7 Recessed Sprinkler Wrench (Figure WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 3).With reference to Figure 1,apply the RECESSED ESCUTCHEON W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque _ 2-7/8"DIA. sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 (73,0 mm) Nm). FACE OF Step C.After ceiling installation and fin- SPRINKLER 2-1/4" DIA. fishing,slide on the Style 15 or Style 20 FITTING (57,2 mm) Closure over the Series TY-FRB Sprin- 5/16±1/4" kler and push the Closure over the "1/2mm) Mounting Plate until its flange comes in (7,9±6,4 mm) (12,7 contact with the ceiling. FLUSH Care and t / ' - - MOUNTING imp 1/8" Maintenance SURFACE (3,2 mm) The TYCO Series TY-FRB,5.6 K-factor, --_--- Upright(TY313)and Pendent(TY323) CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) Sprinklers must be maintained and ser- TY-FRB PLATE viced in accordance with this section. 7/8"(22,2 mm) FIGURE 5 Before closing a fire protection system SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) main control valve for maintenance WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 work on the fire protection system RECESSED ESCUTCHEON that it controls, obtain permission to shut down the affected fire protection Modified sprinklers must be replaced. standards of any other authorities hav- systems from the proper authorities Sprinklers that have been exposed to ing jurisdiction. Contact the installing and notify all personnel who may be corrosive products of combustion, but contractor or sprinkler manufacturer affected by this action. have not operated,should be replaced regarding if theycannot be completely cleaned g g any questions. Absence of the outer piece of an p y rec- escutcheon, which is used to cover by wiping the sprinkler with a cloth or Automatic sprinkler systems are a clearance hole, can delay sprinkler by brushing it with a soft bristle brush. ommended to be inspected, tested, and maintained by a qualified Inspec- operation in a fire situation. Care must be exercised to avoid dam- tion Service in accordance with local The owner must assure that the sprin- age to the sprinklers before,during,and requirements and/or national codes. klers are not used for hanging any after installation. Sprinklers damaged objects and that the sprinklers are only by dropping, striking, wrench twist/ cleaned by means of gently dusting slippage,or the like,must be replaced. with a feather duster;otherwise, non- Also, replace any sprinkler that has a operation in the event of a fire or inad- cracked bulb or that has lost liquid from vertent operation may result. its bulb.(Ref. Installation Section.) Sprinklers which are found to be leak- The owner is responsible for the ing or exhibiting visible signs of corro- inspection,testing,and maintenance of sion must be replaced. their fire protection system and devices Automatic sprinklers must never be in compliance with this document, as well as with the applicable standards - painted, plated, coated, or other- of the National Fire Protection Associa- wise altered after leaving the factory. tion (e.g., NFPA 25), in addition to the TFP172 Page 4of4 P/N* 77 - XXX - X - XXX I I SPRINKLER TEMPERATURE FINISH RATINGS SIN 1 NATURAL BRASS 135 135°F(57°C) 370 5.6K UPRIGHT(1/2"NPT) TY313 3 PURE WHITE(RAL9010)°° POLYESTER 155 155°F(68°C) 371 5.6K PENDENT(VT NPT) TY323 q SIGNAL WHITE(RAL9003) POLYESTER 175 175°F(79°C) Use suffix"I"for ISO 7-1 connection; for example,77-370-4-175-I 9 CHROME PLATED 200 200°F(93°C) "Eastern Hemisphere sales only 286 286°F(141°C) TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Ordering Warranty Procedure For warranty terms and conditions,visit Contact your local distributor for avail- www.tyco-fire.com. ability.When placing an order,indicate the full product name and Part Num- ber(P/N). Sprinkler Assemblies with NPT Thread Connections Specify:Series TY-FRB Upright or Pen- dent(specify)Sprinkler, SIN (specify), K=5.6,Quick Response, (specify)tem- perature rating, (specify) finish, P/N (specify,refer to Table A). Recessed Escutcheon Specify:Style 15 Recessed Escutcheon with(specify*)finish, P/N(specify*) Specify: Style 20 Recessed Escutch- eon with(specify*)finish,P/N(specify*) *Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 Copyright CO 2014 Tyco Fire Products,LP. All rights reserved. ,t�,/co TEFLON is trademark of The DuPont Corporation. `f Fire Protection Products Eddythread 40 A Lightweight Schedule 40 Replacement Pipe That Has a Corrosion Resistance Ratio of 1.0 Bull Moose Tube Company has been making pipe for a long time and is recognized as a producer of quality pipe products. Eddythread 40 is designed with the same thoroughness as our other fine pipe products and now our customers have an option to buy a carefully designed replacement for Schedule 40 that: • Has a Corrosion Resistance Ratio of 1.0 • Has a Pressure Rating of 300 psi • Is Lighter Weight Than Schedule 40 • Is Approved by Factory Mutual and Listed by Underwriters Laboratories • Is Produced in Accordance to ASTM A-135 and A-795 • Can be Used With Standard Schedule 40 Threaded Fittings, Couplings and Valves • Is Produced From Steel With Excellent Properties of Strength and Threadability • Can be Used in Wet, Dry, Preaction, and Deluge Type Sprinkler Systems* • Offers Lower Freight Costs EDDYTHREAD 40 SPECIFICATIONS NOMINAL PIPE SIZE(in) WEIGHT(lbsift) 1.D. On) BUNDLE SIZE 1 1.461 1.083 70 1 1/4 2.070 1.418 51 1 1/2 2.547 1.654 44 2 3.308 2.123 30 CORROSION RESISTANCE RATIOS NOMINAL PIPE SIZE f SCHEDULE 40 EDDYTHREAD 1 1.00 1.00 1 1/4 1.00 1.00 1 1/2 1.00 1.00 2 1.00 1.00 *Eddythread 40 can be hot dipped galvanized to meet FM's requirement for dry systems .,._ ilZ .>. rte..m a.:.,.-.•3y. ..'#t...,.m' k / C/►1 1819 Clarkson Road For additional information, ,1� \ (fit`/ Chesterfield,MO 63017 contact your salesperson todayat c .L us J ( BULB Most=TUBE CpMpgNy (800)325-4467 (800)325-4467 or(636)537-2600 USTEo v FAX:(636)537-2645 in the USA,or from Canada www.bullmoosetube.com call(800)882-4666 A CCAPAAO)company e-mail:sales )bullmoosetube.com All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurnng obligation 8/08 Ductile Iron Fittings- Class 300 UL/FM c us 41/10" APPROVED LISTED Fig. 35E 3-90°Elbow A - Size .' Part N mb ` , A . .. packinL , Weight . u er - . - IIIP'Apirmr,,.. ,,,.. in 'in Inner ' aster lb I ___-I.,\, 1/2 35E 3004 1.13 100 200 0.2 'll 1 'S : '3/4, ' - 35E 3006 1.31 ''''' 70 "' ,- 140 , ; 0.3 , iiiiiPibil I A 1 35E 3010 1.50 40 80 0.5 IMM. '' ''',,17,,i/4 ,.., ' 36E 3012 ,, 1.78 ' ., 26; ' 60' 0.8', 1-1/2 35E 3014 1.94 18 36 1.1 2, -:35E3820 A- 2.25 -- ' 10 : A' 20 .., : - 1- 1.8 2-1/2 35E 3024 2.70 4 8 3.2 Fig. 35RE3-90°Reducing Elbow IIIB ,Size- - -:. ''' Part Number -'' 4,- ,- B ,- ii,.. . 'Packing .., - weight ,, 1 .''in ' , , ..• . in' , , '''''' in -, „ Inner ,.Master lb 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3 11 1?(1/2.0 4§11001,00q4„ , '1.N ''''2. , ,,;*-1:46,, 1 4 7ps '4"-',14d: ' -0.4 I A 1 x 3/4 35RE3010006 1.38 1.45 50 100 0.4 14',1/4. *1/?..,., - .4f1...Wit964., ''' ----1:40 * :- 4:07'-- *.p$'.. .** .to* * 45 1-1/4 x 3/4 35RE3012006 1.45 1.63 35 70 0.6 :,... 4-114 i,(-441 , ,,3644E361016' 44 15 .&?4" 1,„6" Ni. : '''Stfi.: ...0:A. . 01.7 1-1/2 x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1I23/41t,,, :8E.AQ-14006;.,, ,..4 :IL, :. Air 4-'-.7§ i.'71:. --1-7-4."-lA ',.tb::! 4 w,g, 1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0.8 4-11?)''i:171.14'n 7t5i4g3:614.0.12 ' '1'' 1,62 Jf -: 1)§8 *4 b::1:84:.;A(1,443..e.: t , 11b7 2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0 2 x1/4 '' ,S5Fit8e0006 -;`,"''' 3.N,, 1* ;„:„ ' !''-1'. 7 .:::„,, ,'.'- i8 P .,. -,,34 ,:,,. „4'1.0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 ;2)'(1z1/4 ,: 1:859:F3020012 11,, 1:90 : ,,,, I2194# 1 .'42,4 >';' 4144?44 4 4 145, A 2 x 1-1/2 35RE3020014 2.02 2.16 10 20 1.5 2*if:40 ,..- .14/2.,....?<I-112 '.: pi9E40249144, ' $'2.16, 4'''' .:-4.5J4„:',,, 446: ,, 4., ,42,,,,. , 2.2 2-1/2 x 2 35RE3024020 2.39 2.60 6 12 2.5 ....'..1:4,1r..1 '...i;g.:*i•I Fig. 35F 3-45°Elbow 'A1,1R1 'Sip'', ' ... -, fr.:4, ).,.., :, , .4 .': 4. 4 .14Packing 4- 44 4 7 Weight - ..,. ... ...Part N$P1C1--,,fr .vInner ...v. ' Master- ''''''-"- lb...,,,. 'Irleitai t: • x6,, 1/2 35F3004 0.88 150 300 0.2 814, .,„ '2'; 4..F 40.08..,, ..,„ "'"' 0,98 ,?- ' ,, 80,:2. ,.,::, 1801, 44 1 35F 3010 1.13 40 80 0.5 3=44 : '..,,:, ,,,4----5.F,Serf i :,., ,,,..„..1. 0 ,. P, '7,26 it* '''' z,50 ',.. 7 7,. 7 oj ,olin IA ,,,,, ,,,:i-12:2 ,,. ,35F 3014 , 1.44 ‘,.., ,4 20 , , 40 .„ ,,,,., , „.„1.0 35F 3020,4g, !.,,„ 1.69 '- „, 10 It 4. ',',' 4 ?14 ',.'4 ' ''''7' ii. l'-:, 4 . 2-1/2 35F 3024 1.95 4 8 2.7 Fig. 35T 3- Tee Siz# ,..part Number ,.. , inA: ": ,, """' ') Packing.: -..`,- ';-.' -Weight, 'alit A 'ir1,11'2'. ' 3'5'T'3004 ' .0 • 1.13 ' - Inner Master.. -- Ma1:0ter ,.. t .6,0lb3, al.. *1 '-' ," 3/4 .,,, '' 36-r 3606: '''' 1:31 - -v30.„ - ' 60 i., ,, -0.5' 1 1 3513010„ 1.50 25 50 0.7 -III 1-114 3513Q12 1,75 Ip 20 1.1 (---A---)1(---/----C 1-1/2 35T 3014 1.94 10 20 1.5 '' '' 8511-80207 '''' ' 225 '''' l 6 12 ''''''' 12 2-1/2 35T 3024 2.70 4 8 4.3 111 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • kV vvwsmithcooper.com : ..-, ...„,. Ductile Iron Fittings- Class 300 UL/FM [ ri pujs::Tr • C DS 411> APPROVED A Fig. 35CP3 -Straight Coupling with Ribs USTED Size - A - Packing' Weight - ., . iPart Number . n , in Inner . Master lb 1/2 35CP3004 1.38 200 400 0.1 3/4 , 35CP3006. ' 1.63 • 100 200•• 0.2 1 35CP3010 1.75 60 120 0.4 1-114 35cP3012 * - ,2.007 .o, 35 ' 4. ••••'. 70 „ 0.5 '. 1-1/2 35CP3014 2.19 25 50 0.7 2, 7 ' q56P3020, 2 2.62 15 ,, '30'. ' 1.2 .4 2-1/2 35CP3024 3.00 9 18 2.2 ,• Fig. 35RC3 -Hex Reducing Coupling a Om Size .,A - ,,,,,, Packing p. -.e 4, Weight Part Number h 1,'-1.• ", - • • in, 1 • In 'Inner- ' ,Ataster,/, ., lb al" A , ,,,11 xx 1/2 ,,, 35RC3010004006 ,,., ,,,,,,i 11z66:.* v * 86:09 ,,,, 1.\,, , 160i*I : ,, 00..43 , ; 1 ._ -.: - 1-1/4 x 3/4 35RC3012006 2.06 40 80 0.6 2*(1,(noi hex) 40Ac.4021*(11 ,...,- ' n-1-",$," P A d.r.-** *-*415 -7:4.fr A , 1,0 Fig. 35HB3 -Hex Bushing Ill B ) ' Size * A. ,...,.. .., ,1*Paskili::** * Weight -.k. Part Number ,d. ' '- '' , 1,1 .0 - *, ...-' i in '4 - -.,`„ in _ inner, •, asterii lb.`'" 1 x 1/2 35HB3010004 1.06 - 180 360 0.2 11711 "10(di4 I * .,' '1111$40-160.0 1 ""'roe '`4.,' '4' *0 77 ''.4- '* 6O i r 1-1 4 x 1 35H33012010 1.19 90 180 0.2 11-112,755 1, , a6H00f40,10,,,- 6 1.25:1,`• , Itt• 1,5''4.' v• ,e. .4Ci:/. 111 ,•-,,, OA, :',1•• ' 1-1/2 x 1-1/4 35HB3014012 1.25 75 150 0.3 *, *k?$l" : -. 5110502g91p, 41438 -0 .,. 3 40' + • ,:. PP 4., 4.i. 4. '?.0%4 4411 2 x 1-1/4 35HB3020012 1.38 40 80 0.6 4` x1-1/2* J.3514E33020014 '''' ,:138 , ''''40•• , .v ' E1.9. 4 : " 40,6 '4,A.,• ..-itiV:• t:i!' Fig. 35SP3 -Square Head Plug olii4 ... Size . ' .i , ,.. -,.t .,A 1.,... * -,, . 'PaCking'.4-' •44 '4 Weight, Part Number.. ' ..T; 7,-,... In in, ,... ,-,, Inner' * It Master,' .,*,,,..431.0, . 14,-..-.- 1/2 35SP3004 0 94 600 1200 0.07 .3...58:P4990: : , ,..1,1,Z '7,:t 5Q 0Q.: :100, . . ' >0./' 1 35SP3010 ' 11 1.25 200 400 0 1 1421 * , *35Sf.364 * ''-* 11:07 44. '4*1.00 : 4 -4 gib ''. * ' =`, 9.,..3, 1-1/2 35SP3014 1.44 80 160 0.4 *,21 * ,.. 7 a5SP3620, * 4Y. f.561, ,1;,- 4.0 45 44 '.-- t 901/ 41.` • 0.0*, $ • pam. Fig. 35U3 7j7 Union with Brass Seat A , siz! 41a7ooer , APacking: ,iilii3ght, inlInir , Rase; ,mosumet.l.w,,m, . .,,, • II 1 1 35U 3010 ,,. 2.19 , 20 40 1.0 S5Y,36121. 4,1•• ' 2".5CE.4• 4.'"`" 0 45 :, : * to'''''' 4.:` '.. 4 1.2:: .0 1-1/2 35U 3014 2.62 10 20 1.7 IhillhWhisepilairffaln 1 1 ,2 • 351-13020 „ ,••• •••:-3.12 ..,,, •,1 .'",- 67 4 , 12 4' 4 ,, , .2„4,„ e 113 SAIITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithco()per.com .CARBONSTULa r 10.52 nFireLock-�-. Otitlet-T c® FM vds LPCB Cgr MED 491a/27 STYLE 922 l- SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS The Style 922 Outlet-T provides a convenient method of incorporating/,3/4,and 1'/15,20 and 25mm outlets for directly connecting sprinklers,drop nipples,sprigs,gauges,drains and other outlet products.Available for 1'/4 through 76.1 mm/32 to 76.1 mm piping systems,Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe.When tightened,the assembly compresses the gasket onto the OD of the pipe.The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard,lightwall,Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. • MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536,grade 65-45-12.Ductile iron conforming to ASTM A-395,grade 65-45-15,is available upon special request. Gasket: • Grade"E"EPDM-Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc.and Approved by Factory Mutual Research for wet and dry(oil free air)sprinkler services up to the rated working pressure using the Grade"E"Type A Gasket System. Bolts/Nuts:Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: • Orange enamel(North America, Latin America,Asia Pacific) • Red enamel(Europe) JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.®2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ictaul1C* REV_G 10.52_1 IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 Far Lock Out 'z't-T STYLE 922 DIMENSIONS Ni°nRc-ireks%Sinzle DiaHole Approx. ter Dimensions-I nchesimilhmeters Weight Each - - FPyt -0.00/-0.0 T. V Italkg YI. 1/2 1 3/16 1.30 1.83 1.10 3.87 2.56 1.0 Z-1 1 321/4 15 30.2 33.0 46.5 27.9 98.3 65.0 045 :-jT 1.28 r 20133126 83 12.19 988.37 .50 5.g 1.1 • Tak Appi 1 13/16 1.52 2.18 1.10 3.87 2.56 1.2 W ti 25 30.2 38.6 55.4 27.9 98.3 65 0 054 11/2 1/2 13/16 1.42 1.95 1.22 4.08 2.56 12 v 40 15 30.2 36.1 49.5 31.0 103.6 65.0 0.54 34 13/16 1.40 1.95 '.22 4.08 2.56 1.2 20 30.2 35.6 49.5 31.0 103.6 65.0 0.54 1 1 3/16 1.64 2.30 1.22 4.08 2.56 1.3 25 30.2 41.7 58.4 31.0 103.6 65.0 0.59 2 50 X 1/2 1 3/16 1.66 2.19 1.46 4.60 2.56 1.3 15 30.2 42.2 55.6 37.1 116.8 65.0 0.59 13/16 1.64 2.19 1.46 4.60 2.56 1.4 20 30.2 41.7 55.6 37.1 116.8 65.0 0.64 1 13/16 1.88 2.54 1.46 4.60 2.56 1.5 25 30.2 47.8 64.5 37.1 116.8 65.0 0.68 2½ 1/2 1 3/16 1.91 2.44 ' 1.71 5.40 2.56 1.6 65 X 15 30.2 48.5 62.0 43.4 137.2 65.0 0.73 34 1 3/16 1.89 2.44 1.71 5.40 2.56 1.6 20 30.2 48.0 62.0 43.4 137.2 65.0 0.73 1 1 3/16 2.13 2.79 1.71 5.40 2.56 1.6 25 30.2 54.1 70.9 43.4 137.2 65.0 0.73 76.1 tom X 1/2 1 3/16 1.91 2.44 1.71 5.50 2.56 1.6 15 30.2 48.5 62.0 43.4 139.7 65.0 0.73 13/16 1.89 2.44 1.71 5.50 2.56 1.6 20 30.2 48.0 62.0 43.4 139.7 65.0 073 1 1 3/16 2.13 2.79 1.71 5.50 2.56 1.7 25 30.2 54.1 70.9 43.4 139.7 65.0 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT(optional) male pipe threads only.Use of male threaded products with special features,such as probes,dry pen- dent sprinklers,etc.,should be verified as suitable for use with this Victaulic product.Failure to verify suitability in advance may result in assembly problems or leakage. *Center of run to engaged pipe end for NPT threads(dimensions are approximate). www.victaulic.com ‘Ictaulie VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.C 2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV G 10,52 2 IPS CARBON STEEL PIPE- HOLE CUT PRODUCTS 10.52 Firet.cfc k?' ()fillet? STYLE 922 PERFORMANCE Equivalent Length of 1 inch Schedule 40 Steel Pipe(per UL Run Size x Outlet Size 213,Section 16)(C=1201',FT .... „ . . . .,.,. . , .— Inches/men . Feethnetert 1 1/4 1 8.5 32 25 2.6 1½ X 1 8.5 40 25 2.6 2 1 8.5 X 50 25 2.6 21/2 x 1 8.5 65 25 2.6 1 8.5 76.1 mm X 25 2.6 *Hazen-Williams coefficient of friction is 120 ... www.victaulic.com X1CtaUlie VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.CO 2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV G 10523 A '2' 1., -T STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing.Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. • WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. • NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 10.52 3355 REV G UPDATED 12/2009 VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. �CtaUIIC" 10.52 Pipe Hangers Fig.200- "Trimline"Adjustable Band Hanger (B-Line Fig.B317ONF) OTOLCCI • Fig.200F- "Trimline"Adjustable Band Hanger with Felt Lining (B-Line Fig.B317ONFF) Fig.200C- "Trimline"Adjustable Band Hanger with Plastic Coated (B-Line Fig.B317ONFC) G L US Fig.200S - "Trimline"Adjustable Band Hanger with Non-Captured NutUSTE 41>Size Range: Fig.200 - 1/2" (15mm)thru 8" (200mm)pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. w Features: ® \ • (1/2" (15mm)thru 2" (5omm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily a B s' installed around pipe. For hanger with non-captured nut order Fig. 200S. n • (21/2" (65mm)thru 8" (2o0mm)) Spring tension on nut holds it securely inf `r, hanger before installation.Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm)thru 8" (200mm)) _ in the USA(UL)and Canada(cUL)for steel and CPVC plastic pipe and Fig•2oo'/2•zoo'/4 Mutual Engineering 3 �� Fig. to'/ Factory 9 g Approved(FM) (/a (20mm)thru 8' (20ommJ). g200-2 Fig.2o0-2t/2to20lLB Conforms to Federal Specifications WW-H-171E&A-A-1192A,Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69&SP-58, Type 10. Maximum Temperature: 650°F(343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. , Order By: Figure number and pipe size Designed to meet or exceed requirements of FM DS 2-0. Fig.200 Fig.200C Fig.200E -..44' Pipe Size Rod Size A B Approx.Wt./100 Part No. in. Imm) in. (mm) in. Imm) lbs. (kg) 200-1/z 112., 1151 3/8"-1 't /8 16 31/8" 179.4► 25/8" (66.7) 11 15.01 200-3/4 3/4' 1201 3/8"-16 31/8" (79.4) 21/2" (63.5) 11 (5.0) 200-1 1" (251 3/8"-16 33/8" (85.7) 25/8" (66.71 12 (5.5) 200-11/4 11/4" (32) 3/8"-16 33/4" (94.0) 27/8" (73.0) 13 (5.9) 200-11/2 11/2" 1401 3/8"-16 37/8" (98.4) 27/8" (73.0) 14 (6.4) 200-2 2" (50) 3/8"-16 41/2" (114.3) 3" (76.3) 15 (6.9) 200-21/2 21/2" (65) 3/8`-16 55 " t /a 11426) 4/8,. (104.71 27 (12.3) 200-3 3" (75) 3/8"-16 57/a" (149.1) 4" (101.6) 29 (13.3) 200-31/2 31/2" 190) 3/a"-16 73/8" (187.3) 51/4" (133.31 34 (15.6) Fig.200S 200-4 4" (100) 3/8"-16 73/a" (187.3) 5" 1127.0) 35 (16.0) 200-5 5" (125) 1/2"-13 91/8" (231.8) 61/4" 1158.7) 66 (30.2) 200-6 6" (150) 1/25'-13 101/8" (257.2) 63/4" (171.4) 73 (33.4) 200-8 8" (200) 1/2"-13 131/8" (333.4) 83/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line Protection Solutions B-Line 21 by Ec'C•11i Threaded Accessories B3205 - Threaded Rod (right-hand threads - both ends) Rico Fig.103) • B3205L -Threaded Rod (right& left hand threads) rL \� Size Range: 3/8"-16 thru 3"-4 rod Specify Length ��lll Material: Steel L, 1� Function: Recommended for use as a hanger support in hanger assemblies. TL th right available with left and right handRod is threaded on both ends l threads-specify Fig. B3205L when oand threads of the length orderinwn.gl. �\l\ll\11111� A Maximum Temperature: 750°F(399°C) Thread Size Finish: Plain.Contact B-Line for alternative finish materials. z- e ,,, and iiia�enais. Order By: Part number, rod size, length and finish Standard Design Load Thread Size Thread Length TL 650°F(343°C) 750°F(399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) B3205-3/s x'L' 3/8"-16 21/2" (63.5) 730 (3.25) 572 (2.54) 83205-1/2 x'L' 1/2"-13 21/2" (63.5) 1350 (6.00) 1057 (4.70) 83205-5/8 x'L' ,- 5/8"-11 21/2" (63.5) 2160 (9.61) 1692 (7.52) L B3205-3/4 x' 'µ 3/4"-10 3" (76.2) 3230 (14.37) 2530 (11.25) ,83205-718 x'L' ' 7/8"-9 31/2" (88.9) 4480 (19.93) 3508 (15.60) B3205-1 x'L'" .= 1"-8 4" (101.6) 5900 (26.24) 4620 (20.55) 83205-11/e x'L' k` ' 11/8"-7 41/2" (114.3) 7450 (33.14) 5830 (25.93) 4 83205-11/4 X'L'e, 11/4"-7 5" (127.0) 9500 (42.25) 7440 (33.09) B3205-11/2 4'L'= "-- 11/2"-6 6" (152.4) 13800 (61.38) 10807 (48.07) 3/4 x' ' 1 B3205-1L 3/4"-5 7" (177.8) 18600 (82.73) 14566 (64.79) 1 205-2 X'L' '. 'e 2"-41/2 8" (203.2) 24600 (109.42) 19625 (87.29) 83205.214 X'L' r 21/4"-41/2 9" (228.6) 32300 ® 25295 (112.51) 83205-21/2x'L' - r 21/2"-4 10" (254.0) 39800 (177.03) 31169 (138.64) ,B3205-23/4 x'L'= 23/4"-4 11" (279.4) 49400 (219.73) 38687 (172.08) B3205-3 x'L', 3"-4 12" (304.8) 60100 (267.32) 47066 (209.35) ATR -All Threaded Rod 120" (3.05m) Lengths (TOLCo Fig.100) Fig. 99-All Threaded Rod Cut To Length ��`,0"'�1111111111�1, Size Range: 3/8"-16 thru 11/2"-6 rod in 120"(3.05m)lengths or cut to length 7 > '� ��� Material: Steel �� �111�111111111111111111 Maximum Temperature: 750°F(399°C) _J � C mi cil vd Finish: Plain.Contact B-Line for alternative finishes and materials. - Order By: Part number, rod diameter and finish s` u ~a Part No.-Size x Length Threads Recommended Load Approx.Wt./100 Ft. ATR Fig.99 Per Inch Lbs. (kN) Lbs. (kg) ATR 1/4"x 120' A; 99-1/4"x length 20 240 (1.07) 12 'ATR 3/e"x 120,, "-99-3/8"x length 16 (5.44)3.1 9 730 (3.24) 29 (13.15) ATR 1/z",x 120 99-1/271(length 13 1350 (6.00) 53 ATR 5/e"X120- ° 99-5/e"x length 11 ( 2160 (9.60) 89 0.37) (40.37) 'ATR 3/4"x'120 99.3/4"x length 10 3230 (14.37) 123 „,ATR.7f47 x 120 - 99-7/8"x length 9 4480 (55.79) (19.93) 170 (77.11) ATR 1r4 120 "' •99-1"x length:, 8 5900 (26.24) 225 (102.06) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. Pipe Hangers&Supports E3-Line 236 Revised 4/28/2014 by FITiN VERTICAL MOUNT SAMMYS SAMMYS° for Wood Not less than Wood Flooring 2"nominal width s Product Features (1 * •No pre-drilling required. A I Not less than 3 nominal •Quick to install using the Sammy thickness(2-1/2") „ Nut Driver with an IRV rnrd!ess of (depthvertical or sideber) illWood Joist drill/driver. mem •Saves time from traditional Double Sheevock methods. For vertical use- Ceiling install in center of lower face. •Reduces installation cost. Minimum 2'embedment into base material for NFPA 13 compliance. Composite/Truss ` Consult trussmanufacturerfor •Made in the U.S.A. r recommended instalabon point 'F7e3dZing maybe requved far GST f '. 25.390.Tool available on page 1 U. Approvals Rod Part Model Screw Ultimate UL Test FM Test Box Case Size Number Descriptions Pullout(lbs) Load(bs) Load(lbs) Qty Qty 77 '1/4 800 GST 110 $441/4x1 , . 210(7/16 0S8j,- A m -115*, r 4 .Z.4. r z 'r 6T4( 4 fly} ' .. r 25'30 1/4" 8003957 GST 200 1/4 x 2" 1760(Fir) 25 125 1/4 .rr r4557 77. GST 366 '' '1/470"3" 2060,0r)' .:„et ;i,. A,,,„:„,„25 -,125 ;fi 3/8' 8006957 GST.75 1/4 x 3/4" 564 (3/4'Ply) 25 125 "lt 3/8" „ 8007957 sty GST 10 1/4 x! 210(7/16'tYS6} 3 a ”, . " :- , ,_/ .., 67.j13/4 PGY} '` ...jt, . 25 125jj J.4 '4 — 3/8 8008957 GST 20 1/4x2" 1760(Fir) 850 175 25 125 3/8 '84,925'''' .,GSTS 1/4 x 2` 1760.(Fit) .. 850 ,ss e 25' ', 125'` 3/8 8009925 GST 25-380 3/8 x 2-1/T 2113 (Fir) 1500 r 25 125 ' '©,, ;- jie .801095..7 ', GST r 1/4 x 3" ,: t 2060(Fir) t ,~<', 0500 1475 "r„,'25,..„. 5 , '125 4< #14 Black 3/8” 8069925 GST 30 SS 1/4 x 3 2060(Fir) 25 125 Nut 81139 w X711 : ;.u� 5011925 '1 GST45.". f 114x4 x,„ "' r 21:r(Ar ` '" �,., ,r', ' —7 ',25 25 ,, Part#8113910 3/8" 8012925 GST 60 1/4 x 6" 2230(Fir) _ �• 25 125 _ 7 .14:1/2" 48013925 . GST 2' " 1/4x2'" 1760'Ar) y r "''';2§...,.., ,.„"125..k, 1/7' 8014925 GST 25-380 3/8 x 2-1/2" 2113(Fir) 25 125 „r < 4.W „ 12~" 801595 '`` GST3 „ 1/432275(F� _' :hW; , x'i.. .. ` 5 ,. 125 — 1/2" 8016925 GST4 1/4x4" 2180(Fir) 25 125 117 v, 1/2" 8017925. . GST6 7- 3/4 '6" `' 4.240(k) " ,4 ?s 45 ;1 X25 .,1_ #14 SW Red Nut Driver Part#8114910 SAMMY Swivel Head° for Wood Product Features ill •Eliminates distortion of threaded rod. •Saves time from traditional methods. •Accommodates up to 3'/='x 12 pitch roof. •Reduces installation cost. •Allows 17°deflection from vertical. •Made in the U.S.A. Approvals Rod Part Model Screw Ultimate UL Test FM Test Min Box Case Size Number Descriptions Pullout(lbs) Load(lbs) Load(Ws) Thickness Qty Qty C3 474..: 4 3 " ,.8139957 Ar.SH-GST 20 1/4x2' ..- 4. 1257(Fir}, - '1050 ;1475* a<> �/ �w 25 .�"125 125 � 3/8" 8141957 SH-GST 30 1/4 x 3" 1720(Fir) 1500 1475 25 125 #14 Black SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes intoNut Driver contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. Part#8113910 For the most up to date information visit www sammysuperscrew.corn 4 01. _' jj