Loading...
Permit (29) CITY OF TIGARD i. MASTER PERMIT COMMUNITY DEVELOPMENT Permit#: MST2017-00257 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 07/10/2017 TIGARD 9 Parcel: 2S109DA18600 Jurisdiction: Tigard Site address: 12758 SW WILLOW POINT LN Subdivision: ARLINGTON HEIGHTS NO.3 Lot: 115 Project: Brooks Project Description: Installation of solar photovoltaic system BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $7,500.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Drains: Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Roof top PV system Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF 0 Owner: Contractor: BROOKS,STEPHANIE A&CLAYTON M SOLARCITY CORPORATION Required Items and Reports(Conditions) 12758 SW WILLOW POINT LN 6132 NE 112TH AVE TIGARD,OR 97224 PORTLAND,OR 97220 PHONE: 503-840-4481 PHONE: 503-894-6903 FAX: 866-445-7459 Total Fees: $360.19 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. YouYmay obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2) . Gc 344. Issued By: .91)0 `e �9 Permittee Signature: Sr,- _{/✓/L25�LI Call 503.639.4175 by 7:00 a.m.for the next available inspection date. �/ This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application Residential II CE1%rEl t}lt Ul Fit', I`ll i)N l City of Tigard Received r l F7 a91' /7 Peril*Na.: A ,i , w 13125 SW Hall Blvd.,Tigard,OR 97223 Platt Re t � 17�^v 'e 7 ;257 �� Phone: 503.718 2439 Pax: 503.598.1'. Pae/By: Inspection Line; 503.639.4175. �N � 8 2017 BAt�v' v � a�Permit: �,,I I p Date Rt�dy/By: )one: t3 See Page 2 for Internet* www.ligard-or, av xnt,a vas.'rs s- 7../..6(.."1„;p;74/ �11 I OF T�II�� _ Supplemental information New construction 0 Demolition Permit fees"are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all 0.2 Addition/alteration/replacement 0 Other equipment,materials,labor,overhead,and the profit for the .‘ . ., . . ',=.. .,,,._,L-,,,,,,-,4',-, `r ;5 % t -s -1, TAwork indicatedon this application. 121 1-and 2-family dwelling ElCommercial/industrial Valuation; $ 7500 ❑Accessory building 0 Multi-family Number of bedrooms: 0 Master builder 0 Other: Number of bathrooms ; 1 t = '. $ , r '''f€;;'''. Eco 46"Pw , NewTotal number of floors: Job site address: 12758 SW WILLOW POINT LN New dwelling area: square feet City/State/ZIP: PORTLAND IR 97224 Garage carport area: square feet Suite/bldg./apt.no.: Project name: BROQK S Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet ; t t4 a s e I f r,, l °', Tax map/parcel no.: , Lai no.: Indicate the value(rounded to the nearest Subdivision: fees*Permit of the work performed. P/p ( dollar)of all equipment,materials,labor,overhead,and the profit for the ' 3r work indicated on this application. Valuation: $ PV ROOF MOUNT Existing building area: square feet New building area: aqua re feet :,t t � '14- Number of stories: Name: STEPHANIE BROOKS Type of construction: Address: 12758 SW Willow Point Ln, ... Occupancy groups: City/State/ZIP:Portland,OR 97224 Existing: Phone:( 1 ) I 4 :1 Fax ( ) Business name: Structural plan , S[11arClty Corp Contact name: review fee(or deposit): Melissa Farias Address: FLS plan review fee(if applicable): -., 6 13 2 NE 112th Ave. City/StateCLiP: Portland OR 97220 Total feesdueuponapplication:, Phone:(503)$94-6903 Fax: ( Amount received: 186a 445-7459 i E-mail Melissa FariasC'SolarCit .comt r ri s r,; � a s : Commercial and residential prescriptive installation of . :- rooftop mounted Photo Voltaic Solar Panel System. Business name:SolarCi ly Corp. Submit two(2)sets of roof plan with connection+ is and fire dep:1 • at access,along w' , r t Oregon Address: 6132 NE 112th Ave Solar Installation S eci.:.: i I Electrical Permit Anpl1C �g� hells tstt I t t: l r t ax i City of Tigard !,/ r 13125 Sw Hall Blvd.,Tigard,aR 97223 itPC tEP Received 4,. Penni'No.: f l i^ v'Z Phone 503.718.2439 Fax; 503. c? ,Plan Review thbecpsrmtt. inspeonan E tae 503 634,4173 (7 7�� + c aorls El gee page 2 tar Internet www tsgard or goo �I, .w Supplementala nrmadaa Q New constructiol] 1<4 A A . R. r!". l A �7} ►t �7 Please cheek all that apply(submit sets ofplant w/items checked below): 1 E ©3ervi et• or feeder 4011 amps or mom Cl Building over three stories [�Demolition 0 Other: where the available Pants decent 0 Marinas and boatyards, rl f r° s s s", ° t'--_,,s �-. exceeds 10,000 amps at 150 volts or 0 Flooding buildings. ices to ground,ort eccds 14 0,00 ©Commercial-use agricultural 1-and 2-family dwelling 0 Comnsereiallindustrial ❑Accessary building a m"far°other instafiations. b�uitdirigs. Multi-Tamely Q Master build ( 0 Fire pimp ❑installation of ISO KVA or t r: t. ' v '° : ©6mergancy system larger separately derived system ❑Addition of new motor load of ❑"A,"h""1-2","1.3" Jab na.: 3ab site address: 1001-IP or more, occupancy. 12758 SW Willow Pgint Ln. 0 Six or more residenuiol units. 0 Rccnzauanal vebieleparks, City/State/ IF: 0 Heahh-cam facilities. ❑Supply voltage far more than Portland,OR 97224 0Hazardouslocations, 600vuitsnominat Suite/tate/Z pt.no.: Project name: 0&Price or fender 600 amps or rrore RRnnK_ c �.� Thi.« . ro Cross street/directions to job site: neaodptiue ata, Fa, Turd New residential single-or multi-family dwelling unit. includes attached garage' Subdivision: Last no.: 1.000 sq.it,arias Less 168.54 4 Ea.add"I 500 sq.ft,or portion 33,92 1 Tax map/parcel na. itom Lim energy,restd.etilial 75.00 2 M=7;;':-7,u€•�l .." � PV �. �EEE Willi above'. .. Limited em rgy,muki«family 75.00 2 residential(with above stl.ft.) Renewable Energy; ® '�see !'age 2 �%,,,`•'' t + .; .,$,$$,:$1,-. ;s F 200 amps orr lewder tion100.Oar relocation 2 s installation altersn � x. 201 amps to 400 amps 133.56 2 Name: STEPHANIE BROOKS 401 amps to 600 amps 200.34 2 Address:12758 SW Willow Point Ln, 601 xlnps to1,000 amps 301.04 2 City/State/ZIP: Portland,OR 97224 Over 1,tro4amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Phone:(503 ) 840 4481 ( Fax:( ) relocation 200 amps or less 59,36 L Owner installation:This installation is being made on property that I awn which is not 201 amps to 410 amps 125.08 2 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 401 amps 10599 amps 166.54 2 Owner signature Date; Branch circuits—new alteration or extension 'er'and a ,. �"' , at:.,, ,a, i A.Fee above ebranchcireedfem above service or feeder fee, Business name: each branch circuit 7.42 2 $OI TCitY Corp. Ii.Fee for branch circuits without Contact name: Melissa Farias service or fncdcr fex,first 56.18 2 branch circuit Address: 613 2 NE 112th Ave Each add'i branch circuit 7.42 2 City/State/Z1P: Miscellaneous service or feeder not Included Portland, OR 97220 ! Each manufactured or rrwdutar 67.84 2 Phone:(503 ) 894 6903 ! Fax::(1866) 445-7459 dwelling service and/or feeder Reconnect only b7.84 2 E-mail:Mel>spa Frlas@SolarCit cam p or tmgatro 0 _., tvt<., Pomp n circ) 67.84 2 _..._ Sign l outline Lighting 67.84 2 Business name: Signal circuits}or limited.energy S +1`_�1 + ! panel,alteration,or extenson, Page 2 2 Address. 6132 NE 112th Ave investigation Each additional ins 4n over allowable in an of the above P a T ,' y Additional inspection(1 hr min) 66.251 hr City/Stat a(Zlis; ' n I Fax: industrial plant(1F hr nu 66.25/hr t+ 6 Phone: 503) 894-6903 (1866) 445-7459n} 7818/ hr inspeenons for which no fee is CCB Lie.:180498 Electrical Lie.: C562 Suprv.Lie.: 58735 a ctficaU listed Y3 hr min 90.0W hr Suprv.Electrician signature,required:Ail Subtotal: - t Print name: DMI: ae: 6.26.17 Plan review(25°/a of permit fee}: Nicholas Ar r strong state surcharge(112%0 of permit fee): Authorized signature: .--,,, ' < TOTAL PERMIT FEE: Print name: 4 Date: .Phis permit application expires if a permitIss not obtained within 180 Melt sSa Farla6.26.17 days after tt her been accepted sa complex. Number or inspections allowed per permit. lenaltdiogttenoa:s1ELC PemiitApp_ELRI:Rf.doe Rev 05/21/2013 M0.�iai15T(t1AA51(iM/1vE11 Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: Fee for all residential systems combined......,. $75.00 llyscriplion I [ PsI Teta/ I • Renewable electrical energy systems: Check Type of Work Involved: 5 kva or less 100.70 2 5.01 to(Ski's 1 133.56 133.56 2 111 Audio and Stereo Systems* 15.01 to 2$kva 200.34 2 Whal_generation systems in excess of 25 kva: D Burglar Alarm 25.1)110 50 kva 301.04 2 El Garage Door Opener* 50.01 to 100 kva 552.26 >100 kva(tee in accordance with 552.26 2 Ll Heating,Ventilation and Air Conditioning OAR 918-309-0040) System* Solar generation systems In excess of 25 kva: Each additional kva over 25 7.42 3 DI Vacuum Systems* >100 kva-no additional charge 0.0 3 Each additional inspection over allowable in any at the above: Ej Other: Each additional Inspection is 56.251 hr 1 charged at an hourly(1 hr min) Inspections for which no fee is S1iCLifiClt1ly hued l6 90.001 hr hr min) Fee for each commercial system. $75.00 Subtotal: (SEE OAR 918-309-0000) Plan review,if required(25%of permit fee): State surcharge(12%of permit fee): Check Type of Work Involved: TOTAL PERMIT PEE: This permit application expires if a permit is nal obtained within 180 D Audio and Stereo Systems days after it has been accepted as complete. Number of Mspt.tiirms allowed per permit. • Boiler Controls D Clock Systems El Data Telecommunication Installation • Fire Alarm Installation ▪ HVAC fl Instrumentation El Intercom and Paging Systems D Landscape Irrigation Control* D Medical D Nurse Calls D Outdoor Landscape Lighting* D Protective Signaling El Other Total number of commercial systems: *Isla licenses are required. Licenses are required for all other installations mil.iidworrnehAEI.C_PertneApp.Elit..r.REaktc lic•05/2 LW 3 in City of Tigard I . Building1,1 Division • ' �I�IN 13125 SW Hall Blvd, Tigard, OR 97223 8 2017 Phone: 503.718.2439 Fax: 503.598.1960 TIGARD Inspection Line: 503.639.4175 �' ��'TIGARI� www.tigard-or.gov BUILDING D ,ISIOI' 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 12758 SW WILLOW POINT LN City: TIGARD Zip: 97224 Owner's Name: STEPHANIE BROOKS Date: 6.26.17 Contractor's Name: SOLAR CITY CCB #: 180498 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation ❑ Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? ® No OSSC or ORSC for design requirements. Is the wind exposure ® Yes If Wind Exposure "Yes", qualifies for "C" or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes ® Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? structures other than If"Yes", qualifies for ® Yes the prescriptive path. above ❑ No 1 I:/Building/Forms/PhotoVoltaic-Checklist.docx • Is the construction material wood and does ® Yes Type of If"Yes", qualifies for the construction qualify Construction as "conventional light n No the prescriptive path. frame"construction? Is the spacing 24 inches or less? Pre-engineered trusses. RI Yes If"Yes", qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. If"Yes", qualifies for ® Yes the prescriptive path. ❑ No Is the combined weight N Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation Fl layout in accordance Yes with Section 305.4(3) of If"Yes", qualifies for the 2010 Oregon Solar n No the prescriptive path. Code? ❑ Metal Single layer If roofing material is RoofingCheck the type of ❑ of wood Yp one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers the prescriptive path. 11 of composition shingle. Is the roof mounted N Yes Connections of solar assembly the solar assembly connected to roof If"Yes", qualifies for n No the prescriptive path., to the roof framing or blocking directly? 2 I:/Building/Forms/PhotoVoltaic-Checkl ist.docx ❑ Yes If"Yes", qualifies for Is the gauge 26 or less? ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directl to inches inches, qualifies for the Y Maximum 60 inches prescriptive path. standing seam metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of If"Yes", qualifies for fastener? 111 Yes the prescriptive path. ❑ No Is the roof decking of WSP min. '/2"thickness, ❑ Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12" o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof ® Yes the prescriptive path. surface. ❑ No 3 I:/Building/Forms/Photovoltaic-Checklist.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing (rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: TRINA Model Number: 260 Listing Agency: UL1703 4 I:/Building/Forms/Photovoltaic-Checklist.docx