Plans (21) , waci 9 lJuel- SW Se 4o/rf AES Radio is located by Fire Panel in Breakroom. BECEIVEP Zzovac JUN 26 2017 POWER 4 AES RADIO ��ZZCir�� COMMUNICATOR BALDING DIVISION A N C 12 m 0 rn 7 p O C CO IAC O °° m -G V SILENT KNIGHT 5700 • 5 try/� Advantis Credit Union rry Rd SIZE Revision Fire Dialer Diagrammatical BG Tigard OR 97223 8.5 Rev rl CCB#55414 INSTALLATION OF NEW AES RADIO 720 NE Flanders DRA KEVINM 11 TO EXISTING SK 5700 FIRE PANEL Portland Oregon 97232 WN j P.503.235.4000 F. ISSUE - Security,Fire and Video Systems 503.235.0363 6-21-2017 SCALE None SHEET 1 of 1 ��A � ES aes-corp.com 6-SECURITY CORPORATION INNOVATION Smart Subscribers for Commercial Fire Alarm Systems 7788F/7744F Series Fire Subscribers sil! 4 Features •AES-IntelliNet'"smart mesh radio networks are self-forming,self-healing,and highly scalable *. •AES-IntelliNet alarm communications technology never sunsets compared to cellular alternatives • Each Smart Subscriber enables multiple paths to a central monitoring station • Option to transmit full data from FACP digital dialer to AES-MultiNet receiver • Simple and fast activation on AES-IntelliNet network Benefits • Most stable and profitable fire alarm communication technology • Network owner-operators retain virtually all RMR • Meets UL 864 Commercial Fire Alarm requirements for primary standalone communication • Ideal drop-in full-function replacement for phone lines • Universal wireless Smart Subscriber Transceivers support all new and legacy FACPs Advanced Wireless Fire Alarm Monitoring AES 7788F/7744F Series Subscribers are the ideal universal wireless communicators for any new or existing fire alarm system. AES-Inte/liNet networks are built using AES Corporation's patented mesh radio communications technology.A Smart Subscriber at each alarm site acts as transmitter, receiver, and repeater of alarm signals across the network. This creates a smart long-range radio network with multiple pathways between each alarm site and the central receiver. Multiple pathways mean multiple redundancies assuring the most reliable delivery of signals and compliance with rigorous industry standards.AES-IntelliNet networks self-adjust to network changes and assure that signals automatically follow the shortest path available as the network of Subscribers grows. Highest Long Term Stability and Profitability AES-IntelliNet remains the most stable and profitable fire alarm communication technology available today in the rapidly changing world of communications.AES private wireless networks never sunset compared to cellular technology and traditional phone lines. AES-IntelliNet networks maximize RMR generated from network alarm communication services because signals are delivered without the need for a costly operations center or cellular service providers. UL 864 Edition 9 Compliant - Primary Standalone Communicators In order to meet UL approval and NFPA compliance, most fire alarm communicators require either a second communication technology or a costly service plan included with sole path cellular alternatives.With AES-IntelliNet alarm communications technology,each standalone AES 7788F/7744F Subscriber provides multiple RF pathways across the mesh radio network to the central monitoring station.To meet compliance standards,only 2 RF paths are required. Please refer to the official NFPA 72 National Fire Alarm and Signaling Code handbook, Chapter 26 (26.6.3.3.2 One-Way Private Radio Alarm Systems/Technology Reference Comparison Table A.26.6.1). Multiple RF Path Reference Guide AES provides a Multiple Path Validation Reference guide detailing how to easily validate .= „:A.6 '.I multiple RF paths at each AES 7788F/7744F Series Fire Subscriber.The guide also t `' provides a complete listing of the codes and standards to which AES-lntelliNet N. products have been tested. To assist Authorities Having Jurisdiction (AHJs)with the fire alarm inspection process, the guile and other valuable installer tools are available for download from the company website.Visit our Fire Marshal Resources page at , .. (http://www.aes-intellinet.com/products/fire/fire-marshal-resources/). AES-lntelliNet® Private Wireless Mesh Network Central I Monitoring ie ✓ L Station AES Network Management System Each Smart IP Link Subscriber has Internet multiple unique1r. �. RF paths rrwet RzE��e IP Link • Alarm Automation 0 AES Fire Subscriber Alarm Panel 4SAES Customer's Premise Each Smart Subscriber acts as transmitter, receiver, and repeater creating a smart long-range radio network with multiple pathways and multiple redundancies.The AES-IntelliNet network is self-forming, self-healing, highly scalable and assures that signals follow the shortest path available as the network expands. Cost Free Supervised Operation AES Subscribers offer fully-supervised operation that includes monitoring of primary and back-up operating power • as well as the radio connection to the AES-IntelliNet network. Each Subscriber performs"Check-ins"with the AES central station receiver at least once every 24 hours which complies with the UL 864 standard for commercial fire alarm communications.The supervision Check-in time can be set to as often as needed for the application. Because the central station owns and Unlike cellular, there operates the long-range wireless network,there is no cost for air time to transmit supervisory signals.This is very different from cellular alternatives is no cost for a i r which require an aggressive supervision Check-in schedule in order to time to transmit comply with UL 864 listing.The high monthly cost for cellular service fees significantly reduce RMR profit. supervisory signals. Full Data Module Option - Ideal replacement for Phone Lines AES Subscribers transmit consolidated alarm, trouble, and supervisory signals triggered by a FACP output relay. Subscribers with an integrated AES-IntelliPro Fire full data module transmit full alarm zone and event codes captured from a panel's digital communicator. Both options individually meet UL and NFPA 72 requirements. AES Fire Subscribers with built-in full data module are the ideal drop-in full-function replacement for phone lines for communicating signals from both new and existing UL commercial fire alarm systems. Replacing phone lines with AES-IntelliNet maximizes RMR profit with significant bottom line impact, unlike with cellular technologies that charge high monthly service fees. How to Order AES Fire Subscribers 7788F 8 Zone Fire Subscriber,8 Supervised Zones,Red Enclosure. 7744F 4x4 Zone Fire Subscriber,4 Reversing Polarity,4 Supervised Zones,Red Enclosure. 7788F-ULP 8 Zone Fire Subscriber,8 Supervised Zones,includes 7794 AES-Intel//Pro Fire,Red Enclosure. 7744F-ULP 4x4 Zone Fire Subscriber,4 Reversing Polarity,4 Supervised,includes 7794 AES-IntelliPro Fire,Red Enclosure. 7788E ULP P 8 Zone Fire Subscriber,8 Supervised Zones,includes 7795 AES-Intel/iPro Fire,Red Enclosure.UL listed for primary standalone communication with fire radios. 7744E ULP P 4x4 Zone Fire Subscriber,4 Reversing Polarity,4 Supervised Zones,includes 7795 AES-IntelliPro Fire,Red Enclosure.UL listed for primary standalone communication with fire radios. 7788F-C 8 Zone Fire Alarm Subscriber.ULC listed for Canada. 7788F-C-ULP 7788F-C Fire Alarm Subscriber with AES-IntelliPro Fire full data module.ULC listed for Canada. Add-on AES-IntelliPro Fire Modules 7794 AES-lntelliPro Fire Full Data Module.UL listed for supplemental communication with fire radios. 7795 AES-IntelliPro Fire Full Data Module(7794)with 7762 Hardware Supervisory Module and 7740 AES Local Annunciator.UL listed for primary standalone communication with fire radios. 7742 7762 Hardware Supervisory Module and 7740 AES Local Annunciator.7762 module provides power and supervision of the 7740 AES Local Annunciator. AES Local Annunciator 7740 7740 AES Local Annunciator.UL listed for use with 7795 module or 7742 module. I Technical Specifications 7788F/7744F Dimensions Backup Battery Antenna Cut/Communication •13.25"H x 8.5"W x 4.3"D •Will charge 12V battery up to 7.5-12 AH, Trouble Output (34cm H x 21.5cm W x 11cm D) •Requires 12VDC 7.5 AH battery for UL 864 •Form C relay;fail secure;rated for Weight Alarm Signal Inputs(subscriber) 24 VDC 1A resistive •Approx.7 pounds(3.2 kilograms), •7788F-8 individually programmable zones Reset Button excludes battery •7744F-4 individually programmable •Located on main circuit board Radio Frequency zones and 4 reverse polarity inputs Operating Temperature •Standard Frequency Range:450-470MHz UI Standards •0°to 50°C(32°to 122°F) (others available in 400-512MHz range •UL 864 Edition 9-Standard for Storage Temperature •Output Power-2 Watts and S Watts g p Control Units and Accessories for Fire •-10°to 60°C(14°to 140°F) Antenna Alarm Systems •Included 2.5 db tamper resistant antenna •UL 365-Standard for Police Station Relative Humidity mounts on enclosure Connected Burglary Alarm Units '0 to 85%RHC,Non-Condensing •Multiple remote antenna options available and Systems Power Input •UL 1681 -Standard for •16.5VAC,40VA transformer(not included) Central Station Burglary Alarm Units (AES 1640,ELK TRG1640, MG Electronics MGT1640-UL Listed for use) 7794 •Transmits full data to AES-MultiNet Input/Output Connections Size receiver using Contact ID or Pulse formats •AES Subscriber-data and power •4.875"x 5"(12.3cm x 12.7cm) •Formats Supported:Contact ID,Pulse •Handheld/PC programming port 3+1,Pulse 4+1,Pulse 4+2,Modem Ile, •Plain Old Telephone Service(POTS) Power Requirements and Modem II1a2incoming phone line •12 VDC nominal,primary and backup •Phone output connection from power provided by the AES RF alarm panel Transceiver Unit •Trouble output(form C relay) Current Consumption •350 mA nominal 7795 7762 •P/N 40-7795 is a kit that includes 7794 •Hardware Supervisory Module module and 7762 Hardware Supervisory module. For 7794,please see Technical Input/Output Connections Size Specifications above •J1 -AES 7794(J2)or Subscriber •2.5"x 4.9375"(6.3cm x 12.5cm) (J1)-data and power Power Input •Input for Subscriber J4 Output •12VDC nominal,power supplied •Input for AES 7740 Local from AES 7794 module or AES Annunciator-data and power 7788F/7744F Subscribers •AES 7740/AES 7794 Trouble Output to Subscriber input zone Current Consumption •40 mA average; 100 mA peak Specifications Subject to Change Without Notice C kil. al ENA* (.:-.W. .44. N. t( PHI About AES Corporation Established in 1974,AES Corporation empowers companies to grow profitable alarm monitoring businesses,and government agencies to enhance security anywhere in the world.By providing the industry's only patented owner operated and controlled private wireless mesh networks,AES ensures superior reliability,low Total Cost of Ownership(TCO)and optimal Recurring Monthly Revenue(RMR)while reducing dependence on service provider infrastructures.The company's flagship AES-IntelliNee systems are deployed in over a half million locations worldwide. For more information, go to or call or contact us at ©Copyright 2014 AES Corporation 1 AES-IntelliNet is a registered trademark of AES Corporation