Loading...
Report INDEX PROJECT: CANTEEN STORAGE UPGRADE Number Descri•tion Manufacturer Model No. 1 Sprinkler Head, TY5151 Tyco ELO 231B 2 Butterfly Valve Tyco BFV-300 3 Swing Check Valves Tyco CV-1 F 4 Riser Manifold Tyco RM-1 5 Pipe Bull Moose Eddy Flow 6 Pipe Bull Moose Sch. 10/40 7 Groove Coupling Victaulic Fire Lock 8 Groove Fittings Victaulic Fire Lock 9 Super Screw Sammy for Wood 10 Sidewinder Sammy for Wood 11 Vertical Screw Sammy for Wood 12 Hanger Afcon #300 13 Attachment Fitting Afcon #077 14 Sway Brace Fitting Afcon #410 15 Sway Brace Fitting Afcon #001/020 • S }ic ;7 WYAT T FIRE PROTECTION, INC. PROJECT 9095 S.W. Burnham Tigard,OR 97223 Fire Hydrant Fire Flow 12670 SW Hall Blvd. ADDRESS 12670 SW Hall Blvd. Tigard, OR CROSS STREET None FLOW HYDRANT 12670 SW Hall Blvd. LOCATION STATIC 100 PITOT RESIDUAL 82 • GPM 1,512 GPM AT 20 PSI 11,083 calculated per NFPA 291 DATED 06-08-17 MONITOR HYDRANT 12670 SW Hall Blvd. LOCATION STATIC 100 RESIDUAL 98 DATED 06-08-17 WITNESS WITNESSED BY TITLE ORGANIZATION City of Tigard Public Works SIGNATURE PERFORMED BY Mike Sayti FIRE SYSTEMS WEST, INC. 600 SOUTHEAST MARITIME AVENUE, SUITE 300 VANCOUVER,WA 98661 HYDRAULIC CALCULATIONS FOR • CANTEEN STORAGE UPGRADE 12670 SW HALL BLVD. , BLDG. #3 TIGARD, OR 97223 DRAWING NUMBER: 1-11-1509 DATE: JUN 12, 2017 -DESIGN DATA- REMOTE AREA NUMBER: 1 REMOTE AREA LOCATION: STORAGE OCCUPANCY CLASSIFICATION:CLASS IV, IN RACKS TO 20' DENSITY: 0.495 gpm/sq. ft. AREA OF APPLICATION: 2,000 sq. ft. COVERAGE PER SPRINKLER: 100 sq. ft. TYPE OF SPRINKLERS CALCULATED: 11.2K ELO231B NUMBER OF SPRINKLERS CALCULATED: 21 *IN-RACK SPRINKLER DEMAND: N/A gpm HOSE-STREAM DEMAND: 500 gpm TOTAL WATER REQUIRED (INCLUDING HOSE) : 1580.8 gpm FLOW AND PRESSURE (AT BASE OF RISER) : 1080.8 gpm @ 73.0 psi TYPE OF SYSTEM: WET WATER SUPPLY Source: CITY Test Date: 6/8/17 Test By:TIGARD PUBLIC WORKS Location: 12670 SW HALL BLVD. 41/1 Static: 90.7 psi Residual: 20 psi Flow: 11083.0 gpm Source Elevation Relative to Finished Flow Level: -3 ft. INSTALLING CONTRACTOR Name: FIRE SYSTEMS WEST, INC. Address: 600 SE MARITIME AVE. , VANCOUVER, WA Phone: 360-693-9906 OR CL#: 49732 NAME OF DESIGNER: B.CULLINANE NICET III #:116257 Calculations performed by HASS under license # 5009058210 , granted by HRS SYSTEMS, INC. (Notes continue after pipe calculations results.) SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 6/12/2017OGRESS\1-11-1509 CANTEEN\1-11-1509 CANTEEN REMOTE AREA.SDF JOB TITLE: CANTEEN REMOTE AREA "'TER SUPPLY ANALYSIS Static: 100.00 psi Resid: 20.00 psi Flow: 11083.0 gpm 120.0 LEGEND 100.CCO. 1AL 1 "Available pressure G 2A? 97.82 psi @ 1580.8 gpm A U 2 /required pressure 80.0 G 90.72 psi @ 1580.8 gpm E P lA "Avail. OnSite Demand Press. R 97.82 psi @ 1080.8 gpm 4111 60.0 2A "Req. OnSite Demand Press. S U 90.72 psi @ 1080.8 gpm _R E A. Source Supply Curve 40.0 B. System Demand Curve ( C. Available at Source P s i ) 20.0 • tis, . ` y�S • • 0.0 ..,II. • -14.7 1 1 1 1 1 1 1 1 24036004800 6000 7200 8400 9600 10800 12000 FLOW (GPM) •ote: (1) Dashed Lines indicate extrapolated values from Test Results (2) On Site pressures are based on hose stream deduction at the source SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 6/12/20170GRESS\1-11-1509 CANTEEN\111-1509 CANTEEN REMOTE AREA.SDF JOB TITLE: CANTEEN REMOTE AREA NFPA WATER SUPPLY DATA 4110 SOURCE STATIC RESID. FLOW AVAIL. @ TODOTALD RPRQSD .r NODE PRESS. PRESS. @ TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SOURCE 100.0 20.0 11083.0 97.8 1580.8 90.7 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 1580.8 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 500.0 GPM 0 GPM OTHER HOSE STREAM ALLOWANCES TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 1080.8 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGEHNOTES (FT) (PSI) M) SOURCE -3.0 SOURCE 90.7 1080.8 BF1 -3.0 - - - - 88.9 - - - - - BF2 -3.0 - - - - 82.9 - UG 2.8 - - - - 76.2 - -BR 4.1 - - - - 73.0 - - - - • - TR 13.5 M 15.8 - - - - 57.5 - - -Ml 19.7 - - - - 54.7 - - - T 19.7 - - - - 52.9 - - -A 19.7 - - - - 34.1 - - -B 19.7 - - - - 34.1 - - -C 19.7 - - - - 34.4 - - - - - D 19.7 E 19.7 - - - - 36.0 - - - - - - F 19.7 - - - - 37.1 - - - G 19.7 - - - - 38.4 - - - H 19.7 - - - - 40.0 - - - J 19.7 - - - - 41.8 Al 21.2 - - - - 30.0 - - -B1 21.2 - - - - 30.1 - - - - - C1 21.2 - D1 21.2 El 21.2 - - - - 34.6 - - -F1 21.2 - - - - 35.8 - - -G1 21.2 - - - - 37.2 - - -H1 21.2 - - - - 38.6 - - -J1 21.2 - - - - 40.2 - - -A2 21.2 - - - - 20.5 - - -B2 21.2 - - - - 20.8 - - -C2 21.2 - - - - 21.8 - - - - - - •. 02 21.2 - - - - 25.7 E2 21.2 - - - - 30.0 - - -F2 21.2 - - - - 32.0 - - -G2 21.2 - - - - 33.4 - - - y SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 6/12/2017OGRESS\1-11-1509 CANTEEN\1-11-1509 CANTEEN REMOTE AREA.SDF JOB TITLE: CANTEEN REMOTE AREA "'ODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE NOTES (FT) (PSI) (GPM) H2 21.2 - - - - 34.1 - - - - J2 21.2 - - - - 34.6 - - - A3 19.7 - - - - 22.5 - - - B3 19.7 - - - - 22.8 - - - C3 19.7 - - - - 24.0 - - - D3 19.7 - - - - 26.6 - - - E3 19.7 - - - - 29.9 - - F3 19.7 - - - - 32.1 - - - G3 19.7 - - - - 33.4 - - - H3 19.7 - - - - 34.1 - - - J3 19.7 - - - - 34.3 - - 1 21.2 K=11.20 21.4 51.8 2 21.2 K=11.20 20.1 50.3 3 21.2 K=11.20 19.6 49.6 4 21.2 K=11.20 19.5 49.5 5 21.2 K=11.20 19.6 49.5 6 21.2 K=11.20 19.8 49.9 7 21.2 K=11.20 21.5 52.0 8 21.2 K=11.20 20.3 50.5 9 21.2 K=11.20 19.8 49.9 10 21.2 K=11.20 19.8 49.8 11 21.2 K=11.20 19.8 49.8 2 21.2 K=11.20 20.1 50.2 13 21.2 K=11.20 22.2 52.8 14 21.2 K=11.20 21.1 51.4 15 21.2 K=11.20 20.6 50.8 16 21.2 K=11.20 20.5 50.8 17 21.2 K=11.20 20.6 50.8 18 21.2 K=11.20 21.0 51.3 19 21.2 K=11.20 25.9 57.0 20 21.2 K=11.20 25.6 56.6 21 21.2 K=11.20 25.6 56.6 i SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 6/12/2017OGRESS\1-11-1509 CANTEEN\1-11-1509 CANTEEN REMOTE AREA.SDF JOB TITLE: CANTEEN REMOTE AREA NFPA2 PIPE DATA 4110 Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) Notes To Node El (ft) PT Tot. (Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 1 Source 0.0 20.00 140 90.7 SOURCE -3.0 90.7 1080.8 BF2 D6.000 T:47.0 52.00 0.0 BF1 -3.0 88.9 1080.8 6.280 G: 5.0 72.00 0.026 1.9 Pipe: 2 0.0 Fixed Pressure Loss Device BF1 -3.0 88.9 1080.8 UG 6.0 psi, 1080.8 gpm BF2 -3.0 82.9 1080.8 0.0 0.0 140.00 140 82.9 Pipe: 3 BF2 -3.0 82.9 1080.8 BR D6.000 E:22.0 22.00 2.5 UG 2.8 76.2 1080.8 6.280 162.00 0.026 4.2 Pipe: 4 0.0 0.0 3.50 120 76.2 UG 2.8 76.2 1080.8 TR A6.000 2T:60.0 60.00 0.5 BR 4.1 73.0 1080.8 6.065 63.50 0.041 2.6 Pipe: 5 0.0 0.0 9.42 120 73.0 BR 4.1 73.0 1080.8 M A6.000 C:32.0 32.00 4.1 TR 13.5 67.3 1080.8 6.065 41.42 0.041 1.7 0.0 0.0 215.75 120 67.3 • Pipe: 6 0.00 1.0 TR 13.5 67.3 1080.8 M1 A6.000 ---- 215.75 0.041 8.8 M 15.8 57.5 1080.8 6.065 0.0 0.0 29.08 120 57.5 Pipe: 7 M 15.8 57.5 1080.8 T A6.000 0.00 1.7 M1 19.7 54.7 1080.8 6.065 29.08 0.041 1.2 Pipe: 8 0.0 0.0 44.33 120 54.7 M1 19.7 54.7 1080.8 J A6.000 ---- 0.00 0.0 T 19.7 52.9 1080.8 6.065 44.33 0.041 1.8 Pipe: 9 0.0 91.5 Jl 51.58 120 52.9 T 19.7 52.9 989.3 H 4.000 0.00 0.0 J 19.7 41.8 1080.8 4.310 51.58 0.214 11.1 Pipe: 10 0.0 80.3 Hl 10.00 120 41.8 J 19.7 41.8 909.0 G 4.000 0.00 0.0 H 19.7 40.0 989.3 4.310 10.00 0.182 1.8 Pipe: 11 0.0 73.6 G1 10.00 120 40.0 H 19,7 40.0 835.4 F 4.000 0.00 0.0 G 19.7 38.4 909.0 4.310 10.00 0.156 1.6 Pipe: 12 0.0 73.7 F1 10.00 120 38.4 G 19.7 38.4 761.7 E 4.000 ---- 0.00 0.0 F 19.7 37.1 835.4 4.310 10.00 0.133 1.3 . SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 6/12/2017OGRESS\1-11-1509 CANTEEN\1-11-1509 CANTEEN REMOTE AREA.SDF JOB TITLE: CANTEEN REMOTE AREA •ipe Tag K-fac Add Fl Add Fl To Frm Node El (ft) PT Fit: L C (Pt) (q) Node/ Nom ID Eq.Ln. F (Pe) Notes -To Node El (ft) PT Tot. (Q) Disch Act ID (ft. ) T Pf/ft. (Pf) Pipe: 13 0.0 81.6 El _F 19.7 10.00 120 37.1 37.1 680.1 D 4.000 ---- 0.00 E 19.7 36.0 761.7 0.0 4.310 10.00 0.112 1.1 Pipe: 14 0.0 122.7 D1 10.00 120 36.0 E 19.7 36.0 557.4 C 4.000 0.00 0.0 D 19.7 35.1 680.1 4.310 10.00 0.091 0.9 Pipe: 15 0.0 183.6 Cl D 19.7 35.1 373.8 B 10.00 120 35.1 4.000 --- 0.00 0.0 C 19.7 34.4 557.4 4.310 10.00 0.063 0.6 Pipe: 16 0.0 186.5 B1 10.00 120 34.4 C 19.7 34.4 187.3 A 4.000 0.00 0.0 B 19.7 34.1 373.8 4.310 10.00 0.030 0.3 Pipe: 17 0.0 0.0 10.00 120 34.1 B 19.7 34.1 187.3 Al 4.000 ---- 0.00 0.0 A 19.7 34.1 187.3 4.310 10.00 0.008 0.1 Pipe: 18 0.0 0.0 B3 19.7 22.8 113.3 A2 10.00 120 22.8 2.500 0.00 0.0 3 19.7 22.5 113.3 2.705 ---- 10.00 0.032 0.3 Pipe: 19 0.0 115.6 B2 10.00 120 24.0 C3 19.7 24.0 113.3 A3 2.500 ---- 0.00 0.0 B3 19.7 22.8 228.9 2.705 10.00 0.117 1.2 Pipe: 20 0.0 124.3 C2 D3 19.7 26.6 228.9 B3 10.00 120 26.6 2.500 ---- 0.00 0.0 C3 19.7 24.0 353.2 2.705 10.00 0.262 2.6 Pipe: 21 0.0 47.5 D2 E3 19.7 29.9 353.2 C3 10.00 120 29.9 2.500 ---- 0.00 0.0 D3 19.7 26.6 400.7 2.705 10.00 0.330 3.3 Pipe: 22 0.0 400.7D3 10.00 120 32.1 F3 19.7 32.1 -81.6 D3 2.500 ---- 0.00 0.0 E3 19.7 29. 9 319.1 2.705 10.00 0.217 2.2 Pipe: 23 0.0 319.1 E3 10.00 120 33.4 G3 19.7 33.4 -73.7 F2 2.500 ---- 0.00 F3 19.7 32.1 245.4 1.3 2.705 10.00 0.133 1.3 Pipe: 24 0.0 245.4 F3 H3 19.7 34.1 -73.6 G2 10.00 120 34.1 2.500 ---- 0.00 0.0 G3 19.7 33.4 171.8 2.705 10.00 0.069 0.7 Alkipe: 25 0.0 171.8 G3 10.00 120 34.3 3 19.7 34.3 -80.3 H2 2.500 --- H3 19.7 - 0.00 0.0 34.1 91.5 2.705 10.00 0.022 0.2 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 DATE: 6/12/2017OGRESS\1-11-1509 CANTEEN\1-11-1509 CANTEEN REMOTE AREA.SDF JOB TITLE: CANTEEN REMOTE AREA L C (Pt) Pipe Tag K-fac Add Fl Add Fl To Fit: (Pe) Notes • Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F To Node El (ft) PT Tot. (Q) Disch Act ID (ft. ) T Pf/ft. (Pf) Pipe: 26 0.0 0.0 1.58 120 34.1 A 19.7 34.1 187.3 1 2.000 T:13.6 13.64 0.7 Al 21.2 30.0 187.3 2.203 15.22 0.220 3.3 Pipe: 27 0.0 0.0 1.58 120 34.1 B 19.7 34.1 186.5 7 2.000 T:13.6 13.64 0.7 B1 21.2 30.1 186.5 2.203 15.22 0.218 3.3 Pipe: 28 0.0 0.0 1.58 120 34.4 C 19.7 34.4 183.6 13 2.000 T:13.6 13.64 0.7 Cl 21.2 30.5 183.6 2.203 15.22 0.212 3.2 Pipe: 29 0.0 0.0 1.58 120 35.1 D 19,7 35.1 122.7 19 2.000 T:13.6 13.64 0.7 D1 21.2 32.9 122.7 2.203 15.22 0.101 1.5 Pipe: 30 0.0 0.0 1.58 120 36.0 E 19,7 36.0 81.6 E2 2.000 T:13.6 13.64 0.7 El 21.2 34.6 81.6 2.203 15.22 0.047 0.7 Pipe: 31 0.0 0.0 1.58 120 37.1 F 19,7 37.1 73.7 F2 2.000 T:13.6 13.64 0.7 Fl 21.2 35.8 73.7 2.203 15.22 0.039 0.6 Pipe: 32 0.0 0.0 1.58 120 38.4 G 19,7 38.4 73.6 G2 2.000 T:13.6 13.64 0.7 01 21.2 37.2 73.6 2.203 15.22 0.039 0.6 Pipe: 33 0.0 0.0 1.58 120 40.0 H 19,7 40.0 80.3 H2 2.000 T:13.6 13.64 0.7 H1 21.2 38.6 80.3 2.203 15.22 0.046 0.7 Pipe: 34 0.0 0.0 1.58 120 41.8 J 19 7 41,8 91.5 J2 2.000 T:13.6 13.64 0.7 J1 21.2 40.2 91.5 2.203 15.22 0.058 0.9 Pipe: 35 0.0 0.0 1.58 120 22.5 A3 19.7 22.5 113.3 6 2.000 T:13.6 13.64 0.7 A2 21.2 20.5 113.3 2.203 15.22 0.087 1.3 Pipe: 36 0,0 0.0 1.58 120 22.8 B3 19.7 22.8 115.6 12 2.000 T:13.6 13.64 0.7 B2 21.2 20.8 115.6 2.203 15.22 0.090 1.4 Pipe: 37 0.0 0.0 1.58 120 24.0 2.000 T:13.6 13.64 0.7 C3 19.7 24.0 124.3 18 2 203 15.22 0.103 1.6 C2 21.2 21.8 124.3 Pipe: 38 0.0 0.0 1.58 120 26.6 D3 19.7 26.6 47 .5 21 2.000 T:13.6 13.64 0.7 410 D2 21.2 25.7 47.5 2.203 15.22 0.017 0.3 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 8 DATE: 6/12/20170GRESS\1-11-1509 CANTEEN\1-11-1509 CANTEEN REMOTE AREA.SDF JOB TITLE: CANTEEN REMOTE AREA Sipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) Notes 'To Node El (ft) PT Tot. (Q) Disch Act ID (ft. ) T Pf/ft. (Pf) Pipe: 39 0.0 400.7D3 1.58 120 30.0 "E2 21.2 30.0 -319.1 D3 2.000 T:13.6 13.64 -0.7 E3 19.7 29. 9 81.6 2.203 15.22 0.047 0.7 Pipe: 40 0.0 319.1 E3 1.58 120 32.0 F2 21.2 32.0 -245.4 G3 2.000 T:13.6 13.64 -0.7 F3 19.7 32.1 73.7 2.203 15.22 0.039 0.6 Pipe: 41 0.0 245.4 F3 1.58 120 33.4 G2 21.2 33.4 -171.8 H3 2.000 T:13.6 13.64 -0.7 G3 19.7 33.4 73.6 2.203 15.22 0.039 0.6 Pipe: 42 0.0 171.8 G3 1.58 120 34.1 H2 21.2 34.1 -91.5 J3 2.000 T:13.6 13.64 -0.7 H3 19.7 34.1 80.3 2.203 15.22 0.046 0.7 Pipe: 43 0.0 0.0 1.58 120 34.6 J2 21.2 34.6 91.5 H3 2.000 T:13.6 13.64 -0.7 J3 19.7 34.3 91.5 2.203 15.22 0.058 0.9 Pipe: 44 0.0 0.0 83.58 120 40.2 410J1 21.2 40.2 91.5 J3 2.000 2E:13.6 13.64 0.0 '2 21.2 34.6 91.5 2.203 97.22 0.058 5.7 Pipe: 45 0.0 0.0 83.58 120 38.6 Hl 21.2 38.6 80.3 H3 2.000 2E:13.6 13.64 0.0 H2 21.2 34.1 80.3 2.203 97.22 0.046 4.5 Pipe: 46 0.0 0.0 83.58 120 37.2 G1 21.2 37.2 73.6 G3 2.000 2E:13.6 13.64 0.0 G2 21.2 33.4 73.6 2.203 97.22 0.039 3.8 Pipe: 47 0.0 0.0 83.58 120 35.8 Fl 21.2 35.8 73.7 F3 2.000 2E:13.6 13.64 0.0 F2 21.2 32.0 73.7 2.203 97.22 0.039 3.8 Pipe: 48 0.0 0.0 83.58 120 34.6 El 21.2 34.6 81.6 E3 2.000 2E:13. 6 13.64 0.0 E2 21.2 30.0 81.6 2.203 97.22 0.047 4.6 Pipe: 49 11.20 57.0 Disch 62.58 120 32.9 D1 21.2 32. 9 65.7 20 2.000 E: 6.8 6.82 0.0 19 21.2 25. 9 122.7 2.203 69.40 0.101 7.0 Pipe: 50 11.20 56.6 Disch 10.00 120 25.9 19 21.2 25.9 9.1 21 2.000 ---- 0.00 0.0 20 21.2 25.6 65.7 2.203 10.00 0.032 0.3 4,ipe: 51 11.20 56.6 Disch 10.00 120 25.6 0 21.2 25.6 -47.5 D2 2.000 ---- 0.00 0.0 21 21.2 25.6 9.1 2.203 10.00 0.001 0.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 9 DATE: 6/12/2017OGRESS\1-11-1509 CANTEEN\1-11-1509 CANTEEN REMOTE AREA.SDF JOB TITLE: CANTEEN REMOTE AREA Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) • Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) Notes To Node El (ft) PT Tot. (Q) Disch Act ID (ft. ) T Pf/ft. (Pf) Pipe: 52 11.20 56.6 Disch 1.00 120 25.7 D2 21.2 25.7 -9.1 20 2.000 E: 6.8 6.82 0.0 21 21.2 25.6 47.5 2.203 7.82 0.017 0.1 Pipe: 53 11.20 52.8 Disch 32.58 120 30.5 Cl 21.2 30.5 130.8 14 2.000 E: 6.8 6.82 0.0 13 21.2 22.2 183.6 2.203 39.40 0.212 8.3 Pipe: 54 11.20 51.4 Disch 10.00 120 22.2 13 21.2 22.2 79.4 15 2.000 ---- 0.00 0.0 14 21.2 21.1 130.8 2.203 10.00 0.113 1.1 Pipe: 55 11.20 50.8 Disch 10.00 120 21.1 14 21.2 21.1 28.6 16 2.000 ---- 0.00 0.0 15 21.2 20.6 79.4 2.203 10.00 0.045 0.4 Pipe: 56 11.20 50.8 Disch 10.00 120 20.6 15 21.2 20.6 -22.2 17 2.000 ---- 0.00 0.0 16 21.2 20.5 28.6 2.203 10.00 0.007 0.1 Pipe: 57 11.20 50.8 Disch 10.00 120 20.6 17 21.2 20.6 -28.6 15 2.000 ---- 0.00 0.0 16 21.2 20.5 22.2 2.203 10.00 0.004 0.0 Pipe: 58 11.20 50.8 Disch 10.00 120 21.0 18 21.2 21.0 22.2 16 2.000 ---- 0.00 0.0 17 21.2 20. 6 73.0 2.203 10.00 0.038 0.4 Pipe: 59 11.20 51.3 Disch 1.00 120 21.8 C2 21.2 21.8 73.0 17 2.000 E: 6.8 6.82 0.0 18 21.2 21.0 124.3 2.203 7.82 0.103 0.8 Pipe: 60 11.20 52.0 Disch 32.58 120 30.1 B1 21.2 30.1 134.5 8 2.000 E: 6.8 6.82 0.0 7 21.2 21.5 186.5 2.203 39.40 0.218 8.6 Pipe: 61 11.20 50.5 Disch 10.00 120 21.5 7 21.2 21.5 84.0 9 2.000 ---- 0.00 0.0 8 21.2 20.3 134.5 2.203 10.00 0.119 1.2 Pipe: 62 11.20 49.9 Disch 10.00 120 20.3 8 21.2 20.3 34.1 10 2.000 ---- 0.00 0.0 9 21.2 19.8 84.0 2.203 10.00 0.050 0.5 Pipe: 63 11.20 49.8 Disch 10.00 120 19.8 9 21.2 19.8 -15.6 11 2.000 ---- 0.00 0.0 10 21.2 19.8 34.1 2.203 10.00 0.009 0.1 Pipe: 64 11.20 49.8 Disch 10.00 120 19.8 • ii 21.2 19.8 -34.1 9 2.000 ---- 0.00 0.0 10 21.2 19.8 15.6 2.203 10.00 0.002 0.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 10 DATE: 6/12/2017OGRESS\1-11-1509 CANTEEN\1-11-1509 CANTEEN REMOTE AREA.SDF JOB TITLE: CANTEEN REMOTE AREA Sipe Tag K-fac Add Fl Add Fl To Frm Node El (ft) PT Fit: L C (Pt) (q) Node/ Nom ID Eq.Ln. F To Node El (ft) PT Tot. (Q) Disch Act ID (Pe) Notes (ft. ) T Pf/ft. (Pf) Pipe: 65 11.20 49.8 Disch "12 21.2 20.1 15.6 10 10.00 120 20.1 11 21.2 2.000 ---- 0.00 0.0 19.8 65.4 2.203 10.00 0.031 0.3 Pipe: 66 11.20 50.2 Disch 1.00 120 20.8 B2 21.2 20.8 65.4 11 2.000 E: 6.8 6.82 0.0 12 21.2 20.1 115.6 2.203 7.82 0.090 0.7 Pipe: 67 11.20 51.8 Disch 32.58 120 Al 21.2 30.0 135.6 2 30.0 1 21.2 21.4 187.3 2.000 E: 6.8 6.82 0.0 2.203 39.40 0.220 8.7 Pipe: 68 11.20 50.3 Disch 1 21.2 21.4 85.3 3 10.00 120 21.4 2.000 ---- 0.00 0.0 2 21.2 20.1 135.6 2.203 10.00 0.121 1.2 Pipe: 69 11.20 49.6 Disch 2 21.2 20.1 35.7 4 10.00 120 20.1 2.000 ---- 0.00 0.0 3 21.2 19.6 85.3 2.203 10.00 0.051 0.5 Pipe: 70 11.20 49.5 Disch 3 10.00 120 19.6 idd 21.2 19. 6 -13.8 5 2.000 ---- 0.00 0.0 IF 21.2 19.5 35.7 2.203 10.00 0.010 0.1 Pipe: 71 11.20 49.5 Disch 5 21.2 19. 6 -35.7 3 10.00 120 19.6 - 4 21.2 19.5 13.8 2.000 ---- 0.00 0.0 2.203 10.00 0.002 0.0 Pipe: 72 11.20 49.5 Disch 6 21 2 10.00 120 19.8 19.8 13.8 4 2.000 ---- 0.00 5 21.2 19.6 63.4 0.3 2.203 10.00 0.030 0.3 Pipe: 73 11.20 49.9 Disch A2 21.2 20.5 63.4 5 1.00120 20.5 6 21.2 19.8 113.3 2.000 E: 6.8 6.8220.0 2.203 7.82 0.087 0.7 NOTES (HASS) : (1) Calculations were performed by the HASS 8.6 computer program in accordance with NFPA13 (2016) under license no. 5009058210 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 (2) The system has been calculated to provide an average 4110 imbalance at each node of 0.001 gpm and a maximum imbalance at any node of 0.064 gpm. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 11 DATE: 6/12/2017OGRESS\1-11-1509 CANTEEN\1-11-1509 CANTEEN REMOTE AREA.SDF JOB TITLE: CANTEEN REMOTE AREA 4110 (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 23.8 ft/sec at pipe 9. (4) Items listed in bold print on the cover sheet are automatically transferred from the calculation report. (5) Available pressure at source node SOURCE under full flow conditions is 97.68 psi with a flow of 1633.24 gpm. (6) PIPE FITTINGS TABLE Pipe Table Name: STANDARD.PIP PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) D N E T L C B G A Ell Tee LngEll ChkVly BfyVly GatVly AlmChk DPV1v NPTee 2.203 6.82 13.64 4.09 15.00 8.18 1.36 13.64 13.64 13.64 2.705 9.36 18.72 6.24 21.84 10.92 1.56 15.60 15.60 18.72 4.310 13.94 27.87 8.36 30.66 16.72 2.79 27.87 27.87 27.87 PAGE: A MATERIAL: S40 HWC: 120411, Diameter Equivalent Fitting Lengths in Feet D N (in) E T L C B G A Ell Tee LngEll ChkVly BfyV1v GatViv AlmChk DPV1v NPTee 6.065 14.00 30.00 9.00 32.00 10.00 3.00 28.00 28.00 30.00 PAGE: D MATERIAL: DIRON HWC: 140 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G N Ell Tee LngEll ChkV1v BfyVly GatVly NPTee 6.280 22.00 47.00 14.00 51.00 16.00 5.00 47.00 0 tiici Worldwide Fire Protection Contacts www.tyco-fire.com Products Series ELO-231B - 11.2 K-factor Upright and Pendent Sprinklers Standard Response, Standard Coverage General concentration of chemicals, and gas/ chemical velocity, should be consid- Description ered,as a minimum,along with the cor- rosive nature of the chemical to which , " TYCO Series ELO 2316 11.2K Standard the sprinklers will be exposed Response,Standard Coverage Upright An upright intermediate level version,:," f and Pendent Sprinklers(Ref. Figure 1) of the Series ELO-231B Sprinklers for are automatic sprinklers of the frangible in-rack applications can be obtained by ` bulb type.They are standard response, utilizing the Series ELO-231 B Upright spray sprinklers that produce a hemi- Sprinkler with the WSG-2 Guard & spherical water distribution pattern Shield, and a pendent intermediate below the deflector. level version of the Series ELO-2316 The 11.2 K-factor,ELO-231B Sprinklers Sprinklers can be obtained by utilizing ' the Series ELO-231 B Pendent were subjected to full-scale,high-piled Sprinkler storage fire tests to qualify their use with the WS-2 Shield. If there is a pos ' in lieu of 5.6 or 8.0 K-factor standard sibility of the pendent intermediate level spray sprinklers for the protection of version being exposed to mechanical 0 high piled storage. damage,a G-2 Guard can be added. , Higher flow rates can be achieved at NOTICE much lower pressures with the 11.2 • K factor,ELO 2316 Sprinklers,making The 11.2 K-factor, Series ELO-231B {; .`.. :' their use highly advantageous in high Upright and Pendent Sprinklers described herein must be installed density applications, such as the pro , tection of high-piled storage. and maintained in compliance with this document,as well as with the applica11 - Wax or lead coatings can be used ble standards of the National Fire Pro- to extend the life of the copper alloy tection Association(NFPA),in addition components used in Series ELO-2316 to the standards of any other authori- sprinklers beyond that which would ties having jurisdiction.Failure to do so • otherwise be obtained when exposed may impair the performance of these r. to corrosive atmospheres. Although wax, lead,and polyester coated sprit-devices. klers have passed the standard corro The owner is responsible for main- sion tests of the applicable approval taining their fire protection system agencies, the testing is not repre and devices in proper operating con- sentative of all possible corrosive dition. Contact the installing contrac- Sprinkler atmospheres. Consequently, it is rec tor or product manufacturer with any ommended that the end-user be con- sulted with respect to the suitability Installation of Series ELO-2318 Pendent Numbers (SINS) of these corrosion resistant coatings Sprinklers in recessed escutcheons will for The any given of ambient corrosive environment. nv rnmntvoid all sprinkler warranties,as well as TY5151 -Upright 11.2K,3/4"NPT temperature, possibly void the sprinkler's Approvals TY5251 -Pendent 11.2K,3/4"NPT and/or Listings. TY5851 -Upright 11.2K, 1/2"NPT TY5151 is a redesignation for Central IMPORTANT SIN C5151. Always refer to Technical Data Sheet TFP700 for the "INSTALLER TY5251 is a redesignation for Central, WARNING"that provides cautions Gem, and Star SINs C5251, G1871, with respect to handling and instal and S2531,respectively. lation of sprinkler systems and corn- TY5851 is a redesignation for Central • ponents. Improper handling and SIN C5851. installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 NOVEMBER 2016 TFP342 TFP342 Page 2 of 4 • 1/2"(12,7 mm) Components: NOMINAL MAKE-IN 1 - Frame —.1111.11.11111.- 3/4" i 2 Seal NPT 1 f Assembly l/1 J' t 1\C .11 \\\ 3 Cap 2-13/16" —_ 2 �_ 5 - Compression (71,4 mm) WRENCHOil THREAD3 +n\ ScrewTYP. FLATS RELIEF 6 - Deflector*/ f j 4 *Temperature 1/2" 1 3/4" 5 ----_j rating is NPT NPT � ��'__ indicated on 6 deflector. 7/16"(11,1 mm) 1/2"(12,7 mm) NOMINAL MAKE-IN NOMINAL MAKE-IN UPRIGHT UPRIGHT PENDENT CROSS TY5851 TY5151 TY5251 SECTION FIGURE 1 SERIES ELO-231B (TY5851),AND PENDENT 3/4"NPT(TY5251)SPRINKLERS,STANDARD RESPONSE Technical Design "FITTING SIDE" TOWARDS SPRINKLER Data Criteria FITTING Approvals UL and C-UL UL and C-UL Listed Listing Requirements �\ FM Approved TYCO Series ELO-231 B 11.2K Standard NYC Approved Response,Standard Coverage Upright WRENCH (Refer to Table A for complete approval and Pendent Sprinklers are to be RRENS • information, including corrosion-resis- installed in accordance with NFPA 13 (END"A") tant status. The approvals apply to standard sprinkler position and area/ 00% the service conditions indicated in the density flow calculation requirements 2 Design Criteria section.) for light,ordinary,or extra hazard occu- FIGURE FIGURE 2 pancies, as well as high-piled storage W-TYPE3 SPRINKLER WRENCH Maximum Working Pressure occupancies (solid-piled, palletized, 175 psi(12,1 bar) rack storage,bin box,and shelf storage Discharge Coefficient including but not limited to Class I-IV Operation K=11.2 gpm/psiv(161,4 Ipm/bar's) and Group A plastics)with a minimum Temperature Ratings residual(flowing)pressure of 7 psi(0,5 The glass bulb contains a fluid that Refer to Table A bar)for wet or dry pipe systems. expands when exposed to heat.When Finishes FM Approval Requirements the rated temperature is reached, the Refer to Table A The 11.2 K-factor, Model ELO-231B fluid expands sufficiently to shatter the Physical Characteristics (TY5151,TY5251 &TY5851)Sprinklers glass bulb, allowing the sprinkler to Frame Bronze are to be installed in accordance with activate and water to flow. Cap Bronze the applicable control mode density/ Sealing Assembly..Beryllium Nickel w/TEFLON area guidelines provided by FM Global. Bulb(5 mm dia.) Glass (FM Approval guidelines may differ Compression Screw Bronze from UL and C-UL Listing criteria.) Deflector Bronze • TFP342 Page 3 of 4 SPRINKLER TEMPERATURE BULB SPRINKLER FINISH TYPE RATING LIQUID NBRASSL , PLATEDE LEAD I WAX COATED COATED I WAX OA COATED 155°F(68°C) Red UPRIGHT 200°F 93°C 3 (TY5151&TY5851) ( ) Green 1,2,3,4 286°F(141°C) Blue 3 3* 155°F(68°C) Red PENDENT (TY5251) 200°F(93°C) Green 1,2,3,4 3 286°F(141°C) Blue 3 Notes: 3` 1. Listed by Underwriters Laboratories,Inc.(UL) 2. Listed by Underwriters Laboratories,Inc.for use in Canada(C-UL) 3. Approved by FM Global(FM Approvals) 4. Approved by the City of New York(NYC)under MEA 291-04-E * Listed/Approved for a maximum ceiling temperature of 150°F(66°C) TABLE A 11.2K SERIES ELO-231B UPRIGHT AND PENDENT SPRINKLERS,STANDARD RESPONSE LABORATORY LISTINGS AND APPROVALS Installation Step 2. Tighten the sprinkler into the The steel rod should be heated only sprinkler fitting using only the W-Type 3 to the point at which it can begin to TYCO Series ELO 231 B 11.2K Stan- Sprinkler Wrench(Ref.Figure 2),except melt the wax,and appropriate precau- dard Response, Standard Coverage that an 8 or 10 inch adjustable wrench tions need to be taken, when handling is to be used for wax-coated sprinklers. the heated rod,in order to prevent the Upright and Pendent Sprinklers must be installed in accordance with this With reference to Figure 1,the W-Type installer from being burned. section. 3 Sprinkler Wrench or the adjustable wrench,as applicable, is to be applied If attempts to retouch the wax coating A leak tight 3/4 inch NPT sprinkler joint to the wrench flats. with complete coverage are unsuc- 4110 should be obtained by applying a min cessfu/,additional wax can be ordered imum to maximum torque of 10 to 20 When installing wax-coated sprinklers in the form of a wax stick (the end with the adjustable wrench, additional of which is color-coded). Only the lbs. ft. (13,4 to 26,8 Nm). A leak tight 1/2 inch NPT sprinkler should be care needs to be exercised to prevent correct color-coded wax is to be obtained by applying a joint should b damage to the wax coating on the used, and retouching of wrench flats maximum torque of 7 to 14 lbs. ft.(9,5 sprinkler wrench flats or frame arms and frame arms is only permitted at to 19,0 Nm). Higher levels of torque and, consequently, exposure of bare the time of initial sprinkler installation. can distort the sprinkler inlet with con- metal to the corrosive environment. With the steel rod heated as previ- sequent leakage or impairment of the The jaws of the wrench should be ously described, touch the rod to the sprinkler. opened sufficiently wide to pass over area requiring additional wax with the the wrench flats without damaging the rod angled downward,and then touch Notes: Do not install any bulb type wax coating.Before wrench-tightening the wax stick to the rod approximately sprinkler if the bulb is cracked or there the sprinkler,the jaws of the wrench are 1/2 inch away from the area requiring is a loss of liquid from the bulb. With to be adjusted to just contact the sprin- retouching. The wax will melt and run the sprinkler held horizontally, a small kler wrench flats. After wrench-tight- down onto the sprinkler. air bubble should be present. The ening the sprinkler, loosen the wrench diameter of the air bubble is approxi- jaws before removing the wrench. mately 1/16 inch(1,6 mm)for the 155°F (68°C) to 3/32 inch (2,4 mm) for the After installation, the sprinkler 286°F(141°C)temperature ratings. wrench flats and frame arms must Do not attempt to make up for insuf- be inspected and the wax coating retouched (repaired) whenever the ficient adjustment in the escutcheon coating has been damaged and bare plate by under- or over-tightening the metal is exposed. The wax coating sprinkler. Re-adjust the position of the on the wrench flats can be retouched sprinkler fitting to suit. by gently applying a heated 1/8 inch diameter steel rod to the areas of wax The Series ELO-231B Upright and Pendent Sprinklers must be installed that have been damaged,to smooth it in accordance with the following back over areas where bare metal is instructions. exposed. Note: Pendent sprinklers are to be Notes: Only retouching of the wax coating applied to the wrench flats installed in the pendent position; upright sprinklers are to be installed in and frame arms is permitted, and • the upright position. the retouching is to be performed Step1. With only at the time of the initial sprinkler pipe thread sealant installation. applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. TFP342 S Page 4 of 4 P/N* 50 - XXX-X- XXX SPRINKLER TEMPERATURE SIN FINISH RATING NATURAL 155 155°F(68°C) 501 11.2K UPRIGHT(1/2"NPT) TY5851 1 BRASS 510 11.2K UPRIGHT(3/4"NPT) TY5151 6 WAX 200 200°F(93°C) COATED 512 11.2K PENDENT(3/4"NPT) TY5251 7 LEAD 286 286°F(141°C) COATED 8 WAX-OVER-LEAD COATED 9 CHROME PLATED TABLE B SERIES EL0231 11.2K UPRIGHT AND PENNDENT DR SELECT KLERS,STANDARD RESPONSE PARTN Care and Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant sprinklers,after has been completed,to warranty Maintenance verifythe the longiterm potential integrity TYCO Series ELO-231 B 11.2K Standard For warranty terms and conditions,visit of the sprinkler coatings. Thereafter, www.tyco-fire.com. Response,Standard Coverage Upright annual inspections per NFPA 25 should and Pendent Sprinklers must be main- suffice;however,instead of inspecting ordering • tamed and serviced in accordance with from the floor level,a random sampling this section. of close-up visual inspections should Procedure Before closing a fire protection system be made,so as to better determine the control valve for maintenance work on exact sprinkler condition and the long Sprinkler Assemblies with the fire protection system that it con- term integrity of the corrosion resistant NPT Connection with trols, permission to shut down the coating, as it may be affected by the PTThread ies EL ection Stan affected fire protection system must corrosive conditions present. Specify:dardResponse (specify 11.2K Stan- beobtainedfrom the proper authorities The owner is responsible for the or Upright) Sprinkler, SIN (specify), and all personnel who may be affected inspection,testing,and maintenance of (specify temperature rating), with by this action must be notified. their fire protection system and devices (specify)finish,P/N(specify from Table Sprinklers that are found to be leaking in compliance with this document, as B) or exhibiting visible signs of corrosion well as with the applicable standards Sprinkler Wrench must be replaced. of the National Fire Protection Asso- Specify: W-Type 3 Sprinkler Wrench, ciation (e.g., NFPA 25), in addition to SpP/ c f : W T-001 Automatic sprinklers must never be the standards of any other authorities painted, plated, coated or other- having jurisdiction.Contact the install- Wax Sticks wise altered after leaving the factory. in contractor or product manufacturer Modified sprinklers must be replaced. (for retouching wrench damaged wax withitany questions. coating) Sprinklers that have been exposed to Specify: (specify Color) color coded corrosive products of combustion,but It is recommended that automatic have not operated,should be replaced sprinkler systems be inspected,tested, Wax Stick for retouching(specify tem- if they cannot be completely cleaned and maintained by a qualified lnspec- perature rating) temperature rated by wiping the sprinkler with a cloth or tion Service in accordance with local Series ELO-231B Sprinklers, P/N by brushing it with a soft bristle brush. requirements and/or national codes. (specify): Red for 155°F 56-065-1-155 Care must be exercised to avoid, Blue for 200°F and 286°F 56-065-1-286 damage to the sprinklers before, during, and after installation. Sprin- Notes: Each wax stick is suitable for klers damaged by dropping, striking, retouching up to twenty-five sprinklers. wrench twist/slippage,or the like,must The wax used for 286°F sprinklers is kler replaced.thataAlso, replacebulb or thatahas the same as for 200°F sprinklers, and, losliquid has a crackedb (Ref. has therefore,the 286°F sprinkler is limited lost scsfrom its bulb Installa- to the same maximum ceiling tempera- tion section). ture as the 200°F sprinkler(i.e., 150°F). • GLOBAL HEADQUARTERS I 1400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 - Copyright©2016 Tyco Fire Products,LP. All rights reserved. taco TEFLON is trademark of the DuPont corporation. Fire Protection Products 0 tqco Fire Protection Worldwide Contacts www.tyco-fire.com Products Model BFV-300/BFV-300C Butterfly Valve Grooved End General Technical Description Data k i The TYCO Models BFV-300 and BFV- Approvals 300C Grooved End Butterfly Valves UL Listed111. are indicating type valves designed for FM Approved use in fire protection systems where CE Certified a visual indication of open or closed VdS Approved valve condition is required. They are Russian Fire Certificate used, for example, as system, sec- CNPP R1 Listed-APSAD tional and pump water control valves. Listed by California State Fire Marshall They have grooved inlet and outlet con- Refer to Tables A,B and C for applicability. nections that are suitable for use with All laboratory listings and approvals are for grooved end pipe couplings listed or approved for fire protection systems. indoor and outdoor use. For applications requiring supervi- Sizes sion of the open or closed state of the 2-12 Inch(DN50-DN300) MODEL BFV-300 SUPER • valve,the Gear Operators for the Model UL/FM Maximum Working Pressure WITH OP SWIITCHES VISORY BFV-300/BFV-300C Butterfly Valves 2-8 Inch(DN50-DN200) 300 psi(20,7 bar) feature two sets of factory installed 10-12 Inch(DN250-DN300)..175 psi(12,1 bar) internal switches each having SPDT VdS Maximum Working Pressure contacts (Ref. Figure 3). The super- 2-8 Inch(DN50-DN200) 300 psi(20,7 bar) visory switches transfer their electri- 10 Inch(DN250) 232 psi(16,0 bar) cal contacts when there is movement 12 Inch(DN300) 175 psi(12,1 bar) 10. from the open or closed disc position Maximum Working Temperaturex during the first two revolutions of the 212°F(100°C)in accordance with UL 1091 handwheel. Materials of Construction Bod NOTICE Body CoatingDuctile Iron - The Model BFV-300/BFV-300C y RILSANDuctilB1Iron Disc Grooved End Butterfly Valves described Disc Seal EPDM Encapsulated herein must be installed and maintained Upper&Lower Stem Stainless Steel Handw00 in compliance with this document, as (BFV-300 rr ck Iron ed painted;BFV-300C black painted) well as with the applicable standards Actuator,2-6 Inch(DN50-DN150): of the National Fire Protection Asso- • IP 65, bronze traveling nut gearbox, ductile ciation, in addition to the standards of iron housing MODEL BFV-300C Actuator,8-12 Inch(DN200-DN300): WITH CLOSED SUPERVISORY any other authorities having jurisdiction. Failure to do so may impair the perfor- h• usi65,brass segmented gearbox,ductile iron SWITCHES mance of these devices. Housing The owner is responsible for main- Tapping Bosses ining their fire protection system Two factory-plugged NPT threaded tapping Y bosses in the valve body are located on the UL 141120 v`ST`ti� and devices in proper operating con- up-and downstream sides of the disc for ® :`��C4'=c dition. Contact the installing contras- connection to valve trim. TappingAPPROVED " ' "' tor or product manufacturer with any sizes: boss ;=f�; questions. _��� , 2-3 inch(DN50-DN80) 3/8 NPT c [VdSJ ft'''i 1 4-12 inch(DN100-DN300) 1/2 NPT ', 100%Silicone Free Model BFV-300/BFV-300C Butterfly Valves E R( TP are produced and assembled using no • silicone lubricants in any form(like grease or aerosol spray)and are suitable for paint Control Valve Seat Leakage or oxygen applications. Class IEC 60534-4 CLASS VI(Type C)Control Valve Seat Leakage according to ANSI/FCI 70-2-2006(ASME B16.104) Page 1 of 8 JUNE 2016 TFP1511 TFP1511 Page 2 of 8 • Nominal Dimensions Weight Nominal Pipe Inches Valve Size OD (mm) (Lbs. Inches Inches D E F G H J kg) (DN) (mm) A B C 10.8 - 2 2.37 3.8 10.63 2.85 4.90 4.92 .28(108,6) (50,5)1.99 0 0 10.8 (DN50) (60,3) (96,4) (270) (72,5) (124,5) ( ) 13.0 2-1/2 2.88 3.8 11.72 3.35 5.5 4.92 4.28 1.99 0 0 15.0 (DN65) (73,0) (96,4) (297,8) (85) (139,8) (125) (108,6) (50,5) 9) — 3 3.8 11.72 3.35 5.5 4.92 4.28 1.99 0 0 13.015 (DN65) 76,1 (96,4) (297,8) (85) (139,8) (125) (108,6 (50,5) (5 9) 3 3.5 3.8 12.22 3.58 5.76 4 9 (2 4.28 1.999) 0 0 13.9 (DN80) (88,9) (96,4) (310,3) (91) (146,3) ( ) (108,6) 6,3) 4 4.5 4.54 13.92 4.29 6.75 4.92 4.28 1.99 4 0 0 16,(7,36) (DN100) (114,3) (115,4) (353,5) (109) (171,5) (125) (108,6) (50,5)) 26.4 5.5 5.83 16 5.16 7.93 5.91 5.79 2.32 0 0 (21.4) (DN—125) (139,7) (148) (406,6) (131) (201,5) (150) (147) (58,9) 11,9 5 5.56 5.83 16 5.16 7.93 5.9155'.9 0 0 26.4 .4) (DN125) (141,3) (148) (406,6) (131) (201,5) ( ) ( ) (58,9) 42 (11 , — 6.5 5.83 17.07 5.71 8.44 5.91 5.79 2.32 0 0 (13,8) 300,42 DN150 165,1 (148) (433,6) (145) (214,5) (150) (147) (58,9) 30,42 6 6.63 5.83 17.07 5.71 8.44 5.91 5.79 .9 2.322) 0 0 (13,8),42 (DN150) (168,3) (148) (433,6) (145) (214,5) ( ) ( ) 8 8.63 5.24 19.67 6.69 9.29 8.86 8.19 2.76 1466} (1.24) 47.18 (D200) (219,1) (133) (499,5) (170) (236) (225) ( ) (70) 4) 10 10.75 6.26 22.46 1.9511.1 11.14 2.91 .211) (1. 65) (335 73.41 (DN250) (273) (159) (570,5) (195) (282) (283) (208) (4) 3) 10.75 6.26 22.46 7.68 282 11.1 (1.14 8.19 283 (208) 2.91747.21 1.65 73.41 (183,1) (41,8) (33,3) (DN250) (273) (159) (570,5) ( ) (282) (283) (74) 12 12.75 6.5 25.39 9.5 12.2 11.14 8.19 2.91 9.96 2.7 89.29 259 9) (68,5) (40,5) (DN300) (323,9) (165) (645) (241,5) (310) (283) (208) (74) 2.7 — 12.75 6.5 25.39 9.5 12.2 11.14 2.91 9.9 9) (68,5) 89.29 (DN300) (323,9) (165) (645) (241,5) (310) (283) (208) (74) ( (40,5) 1/2" NPT INDICATOR G F CONDUIT FLAG • CONNECTION GEAR t re I11 W9 OPERATOR OO EL C I 5 + 'I HANDWHEEL BODY,. .) D B TAPPING.-----I, H BOSSES } ' ' DISC �— C III J -- --A FIGURE 1 MODEL BFV-300/B NOMINAL GROO ED ONSVED D BUTTERFLY VALVE • TFP1511 111110 Page 3 of 8 No. Part Material Qty. No. Part Material Qty. No. Part Material Qty. ASTM 01 Body A-536 1 15 Spring Pin M A 228 8 1 30 Bolt(Round) ASTM A-167 3 02 Upper Stem AISI 410 1 16 Indicator ASTM ASTM A-619 1 31 Plate Washer 4 03 Lower Stem AISI 410 1 17A-167 0-Ring NBR 1 32 Switch Assembly - 1 04 Disc EPDM 1 18 Cover Gasket Paper 1 33 T/R Bolt ASTM A-307 2 05 0-Ring(P12) EPDM 4 19 Spring Pin ASTM 1 34 Tapping Screw Oiless B/R S10C 1 05x1Tx25 A-228 ST3.5 x 7.5 06 (MB1410) - 4 20 0-Ring(P10) EPDM 1 07 End Cap 35 Tooth Washer 4# S10C 1 2-1/2-4 Inch EPDM 1 21 Worm Shaft AISI 410 1 36 ASTM Lever A-619 1 08 Gear Box A-536 1 22 Bushing(1) FD-0205-45 1 37 — Connector 1 Traveling Nut 09 2-6 Inch Bronze 1 23 Collar FD-0205-45 1 38 Sticker Segment Gear - 1 8-12 Inch C3604BD 1 24 Spring Washer ASTM 4 39 Sticker A-167 - 1 10 Bushing(2) FD-0205-45 1 25 Hex Bolt ASTM M8 x 20L A-167 2 40 Spring Pin ASTM 1 11 Cover ASTM 1 26 Hex Bolt ASTM 03x0.6Tx25 A-228 A-619 M8 x 25L q-187 2 Headless Plug 12 Bushing Fe 1 27 Gasket Paper 1 2-3 Inch 13 Headless Wrench ASTM 1 28 Spring Pin ASTM 41 ASTM 2 Bolt M5 x 7L A-307 04x0.8tx25 A-228 1 Headless Plug A-307 14 Stem Housing Fe 1 29 Handwheel ASTM 1/2 NPT A-536 1 4-12 Inch 0 35 34 37 33 30 37 33 35 36 ,%.„...,--...,•-•� 30 32 ull kI mo34 t 32 I�C�'��L 36 / ■UIG 1N 38,39 / (�.L:/!28 ._� r■ 38,�r �� —" 31 C 28 �` 31 30 19, 30 29 20 40 17 14 12 18 19, 29 20 40 17 14 12 18 16 IU 11 I 11 16 21 = IN 15 API�� 21 ' 15 22 �fs�$ IL�al 09 piggi.T., 1 ral�Illl���ta1 13 I�';�� �� 'i 27 =� 22 '�r��r- 09 ��`�r-+�1 23 (Sr 08 ,� 23 i .. : 27 �,_. 25 III I r 08 ,/ 24 CII 05 1 l 24 IIl 25 ■_ ■ �,- JIL.26 ■ 05 C 25 02 !■! 25 Ij� 26 02 1,sX-m_ L9 01 1U 41 i 01 IE 41 04 03 111 :r� 04 1 � 03 ■ 06 I� 07 06 I� iri BFV-300 Normall Oen Valv y p e BFV-300C Normally Closed Valve Supervisory Switch Arrangement Supervisory Switch Arrangement • FIGURE 2 MODEL BFV-300/BFV-300C GROOVED END BUTTERFLY VALVE ASSEMBLY TFP1511 Page 4 of 8 110 FLOW RATE IN LITERS PER MINUTE(LPM) (1 GPM=3,785 LPM) 200 400 600 1000 2000 4000 6000 10000 20000 9.0 I 1111 1 1 1 1 I I IJ I I II I II I I I I III 1) 111 I l I 060 8.0 0,50 I 7.0 I — — _ , IlIflilir10,40 6.0 I, ,���r� 11 5.0 ! / iN1► nr ��...�■!wwn� �::1^n�:1 0,30 4.0 L-.----29 FAMINIM 111•1111111114111111111011M M M.- '-p AC- ■ �■�lNNINIIn il a I ,j- IN MININIENIMIUMINISINIMINIIIIIINNINNIAN v ' is V (� /�_a�_m-� _ �■_IIII1111' 0,20 z 111IIIII CO O = 2.0 N A \: ■ O`er- d � Z 1 � : � I {� 1 • 1 Illillill' � o w wW z = s �, w � D < 1 l� ■■ , O , o ' ��i■Cnno.u■iiill m (1)Q li i�� n: `ti • V. O= cli/I I A Ammo - �INIEf{ilt I 0 o LU ■ , ■ ,' _■ ■r■�DAIIIII;- 0,10 w u o_ ■ ■ Z I 0,091rr - w �� ■ , AM �� a AIM , uaIa lllllli 1 a IN A I z 11111►111 0,08 a Q A 0 p - 1ai10011n►1l 0,07 a z o • �: I /� = z II - =wpm. z_ z 1.0 N ��i 40 V - �■ L■.■mnun - 0,06 0z O0.9 I r ��■ �� �■■■� ? !� r ■ o rI mum 1 O z 1 i �� � (0o� N� i �� anon - 0,05 z �� p. . cy ? �$ '�� �1 MI /� /1=__ Z per' �l Mo.- 0,04 1 - Wiril. 111.41111.11.1111V��iwww- - U r z ■— (" ru rw� Frw=ww�• w��ww Ai .1 0.6 mow• �w ��■��w ■�w��►����■� Z U uo 0.5 rr.+ '��ii� �.���i>-�� o AEI U ui A 0,03 -.rte ����is�i��i i_�r mi � '� i.: Z n 0.4 �� -2:1mji w �, ��mil�" ���r� �■r. . �- MIT-; 1- )� "wImir/ALUI AEll mmil■a;[tea.-wAU A■ I j rNI MI•1 0.3 A 50 60 80 100 200 400 600 800 1000 2000 4000 6000 FLOW RATE IN GALLONS PER MINUTE(GPM) GRAPH A MODEL BNOMINAL PRESSURE D DROP VERSUS FLOW OVED END LY VALVE YELLOW r-- -1 YELLOW Iu S-1 FIRE ALARM COMMON(WHITE) COMMON(WHITE) END OF LINE \., :� RESISTOR CONTROL PANEL RED RED OR SUPERVISORY I NEXT DEVICE CIRCUIT - MODEL BFV-300/BFV-300C O GREEN L OPERATOR CASE GEAR OPERATOR ---y I -7- GAOUND CONTACT RATINGS: I I BLUE 16A 125V/250 VAC i 5A 24VDC SWITCH S-1,2 LEADS PER CONTACT SWITCH S-2,1 LEAD PER CONTACT S-2 i COMMON(BLACK) i I I ORANGE AUX.DEVICE VOLTAGE �-------J (BELL OR HORN) SOURCE FIGURE 3 MODEL BFV-300 BUTTERFLY VALVE OPEN POSITION-SUPERVISORY SWITCH OPEN POSITION MODEL BFV-300C BUTTERFLY VALVE CLO S D POSITION OH WIRIN-G SUPERVISORY SWITCH CLOSED POSITION TFP1511 • Page 5 of 8 Nominal Pipe Max. Part Number Agency Listing/Approval Valve Size O.D. PSI BFV-300 BFV-300C Inches I(mp)s (bar) Su OPENtch Supv.Switch CE UL FM VdS CA Fire CNPP PAVUS Russian Fire CLOSED Marshall 2 2.38 300 Cert. 59300G020WS 59300G020WSC ,/ ✓ ✓ ,/(DN50) (60,3) (20,7) 2-1/2 2.88 300 59300G025WS 59300G025WSC ✓ / / ✓ ✓ (DN65) (73,0) (20,7)- 3 ✓ / DN65 76,1 (20 7)0 59300G026WS 59300G026WSC ,/ ,/ / / ✓ ✓ 3 3,5 300 59300G030WS 59300G030WSC ✓ / / ✓ ✓ (DN80) (88,9) (20,7) ✓ ,/ { 4 ) 4 300 59300G040WS 59300G040WSC ✓ / ,/ ,/ ✓ DN100 (114,3) (20,7) - / ✓ 5.5 300 59300G056WS 59300G056WSC / / ✓ DN125 (139,7) (20,7)5 ✓ ,/ (DN125) (415,3) (230,7) - 59300G050WS 59300G050WSC / / / ✓ 6.5 / ✓ DN150 (165,1) (20�) 59300G066WS 59300G066WSC ,/ I ,/ ,/ / ✓ 6 6.63 300 59300G060WS 59300G060WSC / / / ✓ ✓ (DN150) (168,3) (20,7) ✓ ✓ 8 8.63 300 59300G080WS 59300G080WSC / / / / ✓ (DN200) (219,1) (20,7) / ,/ 10 10.75 175 59300G100WS 59300G100WSC ✓ / ✓ / ✓ ,/(DN250) (273) (12,1) - 10.75 175 , 59300G106WS 59300G106WSC ,/ V / ✓ (DN250) (273) (12,1) ✓ ✓ 12 12.75 175 59300G120WS 59300G120WSC ✓ (DN300) 323,9 (12,1) / ,/ ,/ 12.75- 175 59300G126WS 59300G126WSC ✓ (DN300) 323,9 (12,1) ,/ / / . TABLE A MODEL BFV-300/BFV-300C GROOVED END BUTTERFLY VALVE WITH INTERNAL SUPERVISORY SWITCHES PART NUMBER SELECTION AND AGENCY LISTINGS/APPROVALS Nominal Pipe Max. Part Number Agency Listing/Approval Valve Size O.D. PSI BFV-300 BFV-300C Inches I(mm) (bar) Su v.Switch Supv.Switch CE UL FM VdS CA Fire Russian CLOSED Marshall CNPP PAVUS Fire 2 2.38 300 Cert. (DN50) (60,3) (20,7) 59300G020AWS 59300G020AWSC / ✓ ,/ ,/ 2-1/2 2.88300 59300G025AWS 59300G025AWSC / / / ,/ ,/ ✓ ,/ ✓ (DN65) (73,0) (20,7) - 3 300 59300G026AWS 59300G026AWSC ✓ / / ✓ DN65 76,1 (20,7) ✓ ✓ ✓ 3 3,5 300 59300G030AWS 59300G030AWSC / / / / I ✓ 07) ✓ / (DNBo) (88,9) (2 4 3 300 59300G040AWS 59300G040AWSC ✓ // / ✓ ✓ ,/(DN100) ,/(11 ) (20,7) - 5.5 300 59300G056AWS 59300G056AWSC ✓ DN125 (139,7) (20,7) / / ✓ ,/ ✓ 5 5.(1453) (6 20,07) 59300G050AWS 59300G050AWSC ✓ / / ✓ (DN125) ✓ ✓ / - 6.5 DN150 (165,1) (20,07) 59300G066AWS 59300G066AWSC / / / / ✓ ✓ ✓ 6 6.63 300 59300G060AWS 59300G060AWSC ✓ / / / ✓ (DN150) (168,3) (20,7) ✓ ,/ / 8 8.63 300 59300G080AWS 59300G080AWSC ✓ / / / ✓ / (DN200) (219,1) (20,7) ,/ ✓ 10 10.75175 59300G100AWS 59300G100AWSC / ,/ / ,/(DN250) (273)73) (12,1) - 10.75 175 / / ✓ (DN250) (273) (12,1) 59300G106AWS 59300G106AWSC / / / / / ,/ ✓ 12 12.75 175 59300G120AWS 59300G120AWSC V (DN300) 323,9 (12,1) ✓ ,/ ✓ • ( - ) 3123,9 (123 59300G126AWS 59300G126AWSC ,/ I DN300 323,9I I TABLE B MODEL BFV-300/BFV-300C GROOVED END BUTTERFLY VALVE WITH CNPP-APSAD LARGE 100 X 100 MM FLAG AND INTERNAL SUPERVISORY SWITCHES PART NUMBER SELECTION AND AGENCY LISTINGS/APPROVALS TFP1511 Page 6 of 84110 Nominal Pipe Agency Listing/Approval Max. Part Russian Valve Size O.D. CA Fire Inches Inches (bar) Number CE UL FM VdS Marshall CNPP PAVUS Fire (DN) (mm) Ce 2 2.38 300 (DN50) (60,3) (20,7) 59300G020NS ,/ ✓ I ✓ 2-1/2 2.88 300 59300G025NS ✓ I ✓ ✓ ✓ ✓ I (DN65) (73,0) (20,7) I I 3 300 59300G026NS ✓ ✓ ✓ ✓ DN65 76,1 (20,7) 3 3,5 300 59300G030NS I I I ✓ ✓ I I (DN4 80) (88,9) (20,7) ✓ ,/(DN100) (144 ,3) (20,07) 59300G040NS ✓ ✓ ✓ ✓ ,/ — 5.5 300 59300G056NS ✓ ✓ ✓ I ✓ DN125 (139,7) (20,7) 5 5.56 300 59300G050NS ✓ ✓ ✓ ✓ 1 1 (DN125) (141,3) (20,7) I I DN— 6.5 150 (165,1) (20,07) 59300G066NS „/ ,/ ✓ ,/ 6 6.63 300 59300G060NS ✓ ✓ ✓ ✓ ✓ I ✓ (DN150) (168,3) (20,7) 8 8.63 300 (DN200) (219,1) (20,7) 59300G080NS ✓ ✓ ✓ ,/ ,/ ✓ ✓ 10 10.75 175 59300G100NS ✓ ✓ ✓ ✓ I I (DN250) (273) (12,1) 10.75 175 59300G106NS I ✓ ✓ ✓ ✓ I (DN250) (273) (12,1) 12 12.75 175 59300G120NS ✓ ✓ ✓ I _ (DN300) 323,9 (12,1) 12.75 175 59300G126NS 7 7 1 1 (DN300) 323,9 (12,1) TABLE C MODEL BFV-300 GROOVED END BUTTERFLY VALVE WITHOUT INTERNAL SUPERVISORY SWITCHES • PART NUMBER SELECTION AND AGENCY LISTINGS/APPROVALS Part Number Bernstein Nominal Gear Bernstein GC SU1Z Valve Size Mounting Bernstein i88 IP65 Ex IP-66/67 ATEX Inches Operator Bracket with i88 IP65 LED Switch (DN) Type Mounting Bolts Regular Switch 24V (Ex II2GSW'd�lh T6 Gb) 2-4 59300SPBRACKET10 (DN50-DN100) Travelling 5-6 Nut 59300SPBRACKET20 (DN125-DN200) 59300SPSW 59300SPSWLED 59300SPSWATEX 8 59300SPBRACKET25 (DN200) Segmented 10-12 Gear 59300SPBRACKET30 (DN250-DN300) Notes: 1. Install a single switch in either bracket mounting position to monitor Open oClosed valve condition ti,, 0i1, c� o I ,� _ - L-----J �; 14 1.Or tI',� �� Bernstien Switch r/ Wiring Diagram TABLED • MODEL BFV-300 GROOVED END BUTTERFLY VALVE WITHOUT INTERNAL SUPERVISORY SWITCHES ACCESSORY EXTERNAL SUPERVISORY S SELECTION AND MOUNTING BRACKETS doh• TFP1511 Page 7 of 8 Installation Nominal Valve Size Part Number Inches The Model BFV-300/BFV-300C (DN) BFV-300,Red Painted BFV-300C,Black Painted Grooved End Butterfly Valves may be 2-4 installed with flow in either direction (DN50-DN100) 59300SPHWHEELIO 59300SPHWHEEL1OB and can be positioned either horizon- 5-8 tally or vertically. (DN125-DN200) 59300SPHWHEEL20 59300SPHWHEEL20B The grooved end pipe couplings 10-12 59300SPHWHEEL30 59300SPHWHEEL30B used with the Model BFV-300/BFV (DN250-DN300) 300C must be listed or approved for TABLE E BFV-300/BFV-300C GROOVED END BUTTERFLY VALVE fire protection service and installed in accordance with the manufacturers REPLACEMENT HANDWHEEL instructions. PART NUMBER SELECTION The Model BFV-300/BFV-300C But- terfly Valve may be installed with any Limited Accessories schedule of pressure class of pipe or tubing that is listed or approved for fire Vl Tarrant External Supervisory Switch and protection. Y Mounting Bracket Conduit and connections For warranty terms and conditions,visit Note: Accessory external supervi- areCo d be electrical accordanceconewithnwww.tyco-fire.com. sory switches and mounting brackets the to be made having jurisdiction and/ are applicable only to valves without or the National Electrical Code. With Ordering factches. tailed internal supervisory reference to Figure 3, the supervisory switches. switch is intended for connection to procedure Refer to Table D for switch models and the supervisory circuit of a fire alarm Contact your local distributor for avail- part numbers. control panel in accordance with NFPA ability.When placing an order,indicate Specify:(specify size)Model BFV-300 72.The auxiliary switch is intended for the full product name and Part NumberButterfly Valve Exter- the unsupervised connection to aux- Grooved End ing iliary equipment in accordance with (P/N). nal Switch Mounting Bracket, P/N Bern- NFPA 70, National Electric Code. stein(speExt, with Switch (specifyy) , Butterfly• Valves stein External model), NOTE: For outdoor applications with Model BFV-300 with Internal P/N(specify) internal supervisory switches,itis rec- Open Supervisory Switches Replacement Parts ommended that wiring connections Specify:(specify size)Model BFV-300 be made at a temperature above 15°F Grooved End Butterfly Valve, Inter- Note: Only items described in this (-9°C),in order to insure sufficient flex- nal Open Supervisory Switches, paction are offered as replacement ibllity of the wire lead insulation. P/N(specify parts. ( p y per Table A) Care and Model BFV-300C with Internal Handwheel Closed Supervisory Switches Replacement handwheel includes pin. Maintenance Specify: (specify size) Model BFV- Refer to Table E for part numbers. 300C Grooved End Butterfly Valve, Model BFV-300, Red Painted Internal Closed Supervisory Switches, Specify: Handwheel, (specify size) Before closing a fire protection system control valve for maintenance or P/N(specify per Table A) Model BFV-300 Grooved End Butter- inspection work on either the valve or Model BFV-300 with Internal fly Valve, P/N(specify) fire protection system which it con- Open Supervisory Switches, Model BFV-300C, Black Painted trols, permission to shut down the APSAD Approved affected fire protection systems must Specify: Handwheel, (specify size) of obtained from the n oritie Specify:(specify size)Model BFV-300 Model BFV-300C Grooved End But- be obtained personneldmwho may bea affectedhGrooved End Butterfly Valve, Internal terfly Valve, P/N(specify) by this decision ht bem notified. Open Supervisory Switches, APSAD Approved, P/N(specify per Table B) The owner is responsible for the inspection,testing,and maintenance of Model SupervisCory with i Internal their fire protection system and devices Closed Approvedpevisory Switches, in accordance with the applicable stan- APSAD dards of the National Fire Protection BFV-3Specify: (specifyvsize) Model Butter- Association(e.g.,NFPA 25),in addition fly Valve, t Grooved Cl End to the standards of any authority having sorVa wi Ihes, Closed p oved, jurisdiction.Contact the installing con- P/Ne Switches,per APSAD Approved, tractor or product manufacturer with (specify per Table B) any questions. Any impairment must Model BFV-300 without Internal be immediately corrected. Supervisory Switches . Specify:(specify size)Model BFV-300 It is recommended that automatic sprinkler systems be inspected,tested, Grooved End Butterfly Valve, and maintained by a qualified inspec- P/N(specify per Table C) tion service. TFP1511 Page 8 of 8 • S 0 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway,Lansdale,PA 194461 Telephone+1-215-362-0700 Copyright©2016 Tyco Fire Products,LP. All rights reserved. t[uCLo RILSAN is a registered trademark of Arkema,Inc. Fire Protection Products • fico 1 Fire Protection Worldwide Contacts www•tyco-fire.com Products Model CV-IF Grooved End Swing Check Valves General The owner is responsible for main- taining their fire protection system Description and devices in proper operating con- dThe TYCO Model CV-1 F Grooved End torrio orr Tp oducttmanufactthe /u er with any f Swing Check Valves are compact questions. and rugged swing-type units that allow water flow in one direction and Technical prevent flow in the opposite direction. A resilient elastomer seal facing on the Data spring-loaded clapper ensures a leak- tight seal and non-sticking operation. Approvals The Model CV-1 F Check Valves are Compliance with CE Pressure designed to minimize water hammer Equipment Directive(PED)and caused by flow reversal. Standards of Engineering Practice The Model CV-1F Grooved End Swing • 2 to 12 Inch(DN50 to DN300): u u 4L illi* Check Valves are furnished with UL and C-UL Listed, FM Approved, ®� C . grooved ends and can be installed Bureau Veritas , using GRINNELL Grooved Couplings APPROVED or GRINNELL Figure 71 Flange Adapt- • 2-1/2 to 10 Inch(DN65 to DN250): �F, ers. The Model CV 1F Check Valves VdSApproved c�++ u have been designed with a removable Certificate No.G4060018 Vdt7 "vi rol cover for ease of field maintenance. Sizes 2e� For fire These valves can be installed horizon- 2 to 12 Inch(DN50 to DN300) and approval i formatio ,cont tally(with cover in the upward position) listing information,contact or vertically with the flow in the upward Maximum Working Pressure Your TYCO representative. direction(Ref. Figure 3). UL/FM-300 psi(20,7 bar) A check valve maintenance kit is avail- VdS 16 bar Installation Valve Assembly Finish The Model CV-1F Grooved End Swing able to allow backflushing through a Red, non-lead paint Check Valves are to be installed in fire department connection without removing the Model CV-1F Grooved accordance with this section: End Swing Check Valve from the riser. Refer to technical data sheet TFP1555. Step 1. The arrow cast on the body must point in the direction of the flow. Model CV-1F is a re-designation for Step 2. Valves installed vertically Central Figure 590E and GRINNELL must be positioned with the flow in the Figure 590F Grooved End Swing Check Valves. upward direction. Step 3. Valves installed horizontally NOTICE must be positioned with the cover The TYCO Model CV-1F Grooved End facing up(Ref. Figure 3). Swing Check Valves described herein Step 4. Grooved end pipe couplings must be installed and maintained in used with the Model CV 1F Grooved compliance with this document and End Swing Check Valves must be with the applicable standards of the installed in accordance with manufac- with Fire Protection Association turer's instructions. (NEPA), in addition to the standards Note:Valves should be installed a rea- of any authorities having jurisdiction. Failure to do so may impair the perfor sonable distance downstream from mance of these devices. pumps, elbows, expanders, reducers, or other similar devices to extend the . Never remove any piping component valve life.Standard piping practices call nor correct or modify any piping defi- a minimum of five(5)times the pipe ciencies without first de pressurizing diameter forgeneral use. and draining the system. Failure to do - so may result in serious personal injury, property damage, and/or impaired device performance. Page 1 of 6 FEBRUARY 2016 TFP1550 TFP1550 Page 2 of 6 Nominal Dimensions Cover Inch Bolt Approx. Nominal Pipe Size (mm) Weight Torque Lbs. Valve Size Pipe O.D. B C D E F J (Nm) Lbs.-ft. ( . Inch nch A (DN) (mm) 2 2.37 6.751.96 (65,3) 3.25 4.75 1.62 18(82,3) (120,7) (4,5) (25) (4,5) (50) (60,3) (1711,,5) (49,8) (49,8) 2-1/2 2.88 8.00 5.38 2.63 309 .87 (1481) (1.63) (54) 14 39 10.0 (65) (73,0) (203,2) (136,7) (66,7) (78,5) (98,3) 41,75) 76,1 mm 3.00 8.00 5.38 2.63 3.09 3.87 5.81) (4 1.63 39 10.0 ) (54) 10.0 (65) (76,1) (203,2) (136,7) (66,7) (78,5) (98,3) 4,5) 3 39 11.0 3 (88,9) (212,6) (145,3) (718,4) (84,1) (98,3) (149,1) (41,7)1 3.31 3.87 5.87 (80) 3.50 8.37 5.72 (54) (5,0) .53 4 114.50 4 3) (244 6) (169,7) (96,5) (92,2) (15, 4) (81,3 4 50 25.0 (100) 1) (46,7) (69) (11,3) .46 4.13 4.90 7.50 1.75 39 29.0 13(125)m (13950 10.5 7.40,,7) (266, ) (188,0) (13 3) (104,9) (124,5) (190,5) (44,5) (54) (13,2) (125) (1451,3) (266,7) (188,0) (13 3) (104,9) (24 5) (190,.46 4.13 4.90 5) (44,5) (54) (13,2) 165,1 ) (165,1)6.50 11.50 8.00(292,1) (203,2) (47,3) (2 14,) (2.50 �0) (193,0) (47,0) (80 7.60 1.85 22) (21,3) 47.0 (150) .50 5.00 7.60 47.0 6 6.63 (292,1)11.50 8.00(203,2) (117,3) (14,,3) (127,0) (193,0) (47,0) (82) (21,3) (150) (168,3) (200) (219,1) (355,6) (257,8) (169,4) (140,2) (1387) (214,9) (54,1) (164) (29,9) 3.00 130 109.7 (250) (273,1) (457,,22) (314,5) (218,9) (162,8) (190,5) (266,07) (76,2) (178) (49,4) 9.93 7.27 7.62 10.62 2.75 130 151.0 (300) (323,9) (533,4) (362,77) (252,2) (184,7) (193,5) (269,7) (69,9) (178) (68,0) • B A .■o ...— rima t I 0 II 0 - D 4... r IL, - �.:s 1 Mk 1/2" - - NPT 1/2" I I -- J NPT Ir E F - FIGURE 1 MODEL CV-1FROOVAD E END SWING DIMENSIONS Care CHECK VALVES NOMICare and system from the proper authorities of the National Fire FPA in Protection Associa- to the and notify all personnel who maybe n of any 25), nrad havn ing Juthe affected by this decision. standardsadar of Contact the installing con uas- Ma►ntenance After placing a fire protection system tor or product manufacturer with any The TYCO Model CV-1F Grooved End in service,notify the proper authorities questions. Any impairments must be Swing Check Valves must be main- and advise those responsible for moni- immediately corrected. tamed and serviced in accordance with toring proprietary and/or central station aic sprinklerorret systems are rec- Before section. alarms. Automommended to inspected, tested, Before closing a fire protection system The owner is responsible for the and maintained be a qualified Insped, • main control valve for maintenance inspection,testing,and maintenance of and maintained aby accordance with local work on the fire protection system their fire protection system and devices tion Service and/or national codes. th this document, as shut Idown tthe affected pre protection well o asp with the lapplicable standards TFP1550 • Page 3 of 6 No. Part Material Qty. No. Part Material Qty. No. Part Material Qty. 1 Body Ductile Iron 1 6 Clapper Facing EPDM 1 14 Locknut Stainless Grade"E" Steel 1 2 Cover Ductile Iron 1 7 S rin Stainless p g Steel 1 15 I NPT Cast Iron 2 1/2 3 Cover Gasket Nitrile Stainless Rubber 1 8 Hinge Shaft Steel 1 16 Adhesive Thread AR Sealer 4 Hex Cap Screw Steel, AR 9 RetainingRingStainless Zinc Plated Steel AR 17 Nameplate Aluminum 1 Clapper,2"-8" Stainless 11 Retention Bolt Stainless 5 (DN50-200) Steel 1 Steel 1 18 Rivet Steel 2 Clapper,10"-12" Ductile Iron 13 RetainingDisc Stainless Stainless (DN250-300) Steel 1 19 Spacer 1 Steel 8 II 4,16 18 17^ 9 ��r111'iaaiiiiiinll�!1I. 5 8 II I) l�l"""ll'1��'!''11 II II ■■ ■■ 2 SEE ,�� . ' �) ) VIEW A %%�//- 2 7 9 2"-8, alWAIIIiwo wiei..3 '``�/ R )II (DN50-DN200 2 1 D"-(DN250-DN300) N0 5 ������� VIEW A 1 I ' I D13 ; 13 4irtSEE 5 / DETAIL B I /„ 11,16 11 • i• 14,16 IN1■ ow ....-„Ni, • •�_t, % i ) /%c / 19 ,c_ / `"Illa NI-11 � \\\\\�`,+ 2'/-8, 6 , 6 5 1 15 10"-12" (DN50-DN200) (DN250-DN300) 0 DETAIL B FIGURE 2 MODEL CV-IF GROOVED END SWING CHECK VALVES ASSEMBLY FLOW RATE IN LITERS PER MINUTE(LPM) (1 GPM=3,785 LPM) 500 700 1000 2000 3000 5000 7000 10000 20000 30000 50000 5.0 iii II A 4.0 �.��q■■� �O �h IN ■ %::::::::1:::::::::::=1:::=:::.7 ,�■g1�RA�M. ��■ ■M 1•1111 ■n,■ nri.■■■■■ii��ri.■ 0,30 .■■■:■■ i , I I■ :dGu..rr�l■1: ■ir�:r�� 11:::..■:■,:■■., 1...■■.■Era'... ■��r■r�■■ ■r. t...�■r�■ii nom' �■■■■■■ O ■ ,num■ 1/.■■■■■■1♦/A■■■■■1•I__ ■■■■■■.■■111■1O■■■■U■■■ui,/■■■ in L■■■■■■ O `�■ 43a, i■nnm a a 3.0 MUM Vim, off,:■o�iiuiuuii'��,iiiiilll/iiii�iiiiiiiiiii'iiiiiiiiii�iii�innri■■■■ 0,20 Z o= IMO" �■ z ,1111111 "sr h iM r 1111/���1 Q a Z MMN■ c �� 0 41■1111 g AINErr ,,�A■M o,/1181111111111111111111111/1116111II Lii ■■■■ - I . 11■1111 „z-,4111111111 2 AN ,�h /1■111■■M1111VA11IN111111111FI■111%1■■1111 a is cc 0 2.0 111111►►/ ;VANN=;;111111 =v 11115 ,11■ I■►1111■■ �.,s1111111111111D5��1/11■■ng o 1•11111W1iN 1111111111•11M a in �.....■■...■. ■ ■■■ MM IMF.....■■.�■..■ cc m cq C� IM■■■7■■IA■E■r4■■■■■■ 71111111 4 ■■■■ i■■■■■= R'�I■■■■n■■O 1FA■.■/p■■��.■■ rn Li., MAMA■ IAMIN AMINM■■■►�p111111 h I■■■ V M■■■■■■■ O' I■■■■■■■■■ O U I W co CC M/�IN�%111■�/IN■■ 111111,,111111111 ,�n� . A •��UI•1 4UU■■■■■■ tih i11 O MIIII���N� co o a CC NIE%N�%■1111,�■N/■1111/111111111■■%/11 cO E■NN■11/ U- IUUUIIICu 0. I l°ice I■■Iu11•■■■■ 0,10 co o — a ■I■/%■�1111/AMEN■/■IINIII111111INKIN111 I■■■■I■1 2/MILIEU XII O / 0,09 w II Q 12■/%Nu1111■■■t1■1141111111111s%1111111/■.■1.111 ro,■■■■1.11 ` = 11111111111 o N►%11111PI■11■511r411N111111►411111r�■■■5■111 4N5■1111 Al=v10 al111II UUIi 0,07 a u, Z 1.0 .1... A■�..... .....roam.. miim..o■■ , .■■ _ ■ 0,07 < z.. 0 D 0.9 am..onn■g... , u..m....■o.■m.. r,m_..■o ,. Am v A•111111■IMmil Q Z �....■r.■o�■. unru■ovu■u..■■■■■r.�..■.■■ �■■ n1 n..o■o■��..■ Z O 0.8 ■■■v■■om■■rAmmuoa►�u■■o.om■.■■■■■n■�■.■■■■■000 ^ 'I1u■■■■■11 .a... 0,06 z I!iiiIIIIJiGiIIIIIIflflujjffhIIigh1IIIIIIiiiiiii1111111►,�����111 ' 1' D�05Jp ! IIll�illil 0,04 0.5 I I 100 200 300 400 600 1000 2000 3000 4000 6000 10000 15000 FLOW RATE IN GALLONS PER MINUTE(GPM) • GRAPH A MODEL CV-1F GROOVED END SWING CHECK VALVES NOMINAL PRESSURE LOSS VS. FLOW TFPI550 Page 4 of 6 • Valve Size Pipe O.D. Inch Inch Part Number (DN) (mm) 2 2.37 59-590-0-020 (50) (60,3) 2-1/2 2.88 59-590-0-025 (65) (73,0) 76,1 mm 3.00 59-590-0-076 (65) (76,1) 3 3.50 59-590-0-030 (80) (88,9) 4 4.50 59-590-0-040 (100) (114,3) 139,7 mm 5.50 59-590-0-139 (125) (139,7) 5 5.56 59-590-0-050 (125) (141,3) 165,1 mm 6.50 59-590-0-165 (150) (165,1) 6 6.63 59-590-0-060 (150) (168,3) 8 8.63 59-590-0-080 (200) (219,1) 10 10.75 59-590-0-100 (250) (273,1) 12 12.75 59-590-0-120 (300) (323,9) TABLE A MODEL CV-1F GROOVED END SWING CHECK VALVES PART NUMBER SELECTION ill Valve Size Pipe O.D. Cover Gasket Part Number Clapper Facing Part Number Clapper Assembly Part Number Inch Inch (DN) (mm) Americas Only EMEA/APAC Americas Only EMEA/APAC Americas Only EMEA/APAC 2 2.37 595907020 97670501 59020EPDM 59020EPDM 97670201A 97670201 (50) (60,3) 2-1/2 8) 595907030 97561801 59025EPDME 59025EPDM 97562801A 97562065 (65) 76,1 mm 3.00 595907030 97561801 59025EPDME 59025EPDM — 97562801 (65) (76,1) 3 3.50 .) 595907030 97561801 59030EPDME 59030EPDM 97562201A 97562201 (80) (88,9) 4 4.50 595907040 97512001 59040EPDME 59040EPDM 97549001A 97549001 (100) (114,3) 139,7 mm 5.50 595907040 97512001 59050EPDME 59050EPDM — 97565501 (125) (139,7) 5 5.56 595907040 97512001 59050EPDME 59050EPDM 97565501A 97562125 (125) (141,3) 165,1 mm 6.50 595907060 97521801 59060EPDME 59060EPDM — 97524101 (150) (165,1) 6 6.63 595907060 97521801 59060EPDME 59060EPDM 97524101A 97562150 (150) (1 ,3) 8 8.63 595907080 97547901 59080EPDME 59080EPDM 97592201A 97592201 (200) (219,1) 10 10.75 595907100 97600001 59100EPDM 59100EPDM 97598001A 97598001 (250) (273,1) 12 12.75 595907120 97600002 59120EPDM 59120EPDM 97647701A 97647701 (300) (323,9) TABLE B MODEL CV-1F GROOVED SWING NUMCHECK VALVES BER SELECTION REPLACEMENT VALVE PARTS * TFP1550 Page 5 of 6 OUTLET Limited Ordering �, Warranty Procedure COVER 'I1111111. i_ 0 ' f For warranty terms and conditions,visit Contact your local distributor for avail- www.tyco-fire.com. ability.When placing an order,indicate �,°�� the full product name and Part Number (P/N). INLET Model CV-1F Check Valve VERTICAL ORIENTATION Specify: Model CV-1 F Grooved End Swing Check Valve, size (specify), COVER P/N(specify per Table A) FLOW Replacement Valve Parts y Refer to Figure 2 to identify Parts. g itsa. Cover Gasket INLET �I0 II OUTLET ecify: Model CV-1F Grooved End ^M-_ Swing Check Valve,Cover Gasket,size (specify), P/N(specify per Table B) HORIZONTAL ORIENTATION Clapper Facing FIGURE 3 Specify: Model CV-1 F Grooved End MODEL CV-1F GROOVED END Swing Check Valve, Clapper Seal SWING CHECK VALVES Facing,EPDM Grade"E",size(specify), PROPER ORIENTATION P/N(specify per Table B) Clapper Assembly Includes items 2,3,5-14,and 17-19. Specify: Model CV-1F Grooved End OP Swing Check Valve,Clapper Assembly, size(specify),P/N(specify per Table B) TFPI550 Page 6 of 6 110 • GLOBAL HEADQUARTERS 1400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 Copyright©2016 Tyco Fire Products,LP. All rights reserved. tacoFire Protection Products • tIJCQ Fire Protection Worldwide Contacts www•tyco-fire.com Products Model RM-1 Riser Manifold Commercial and Residential General Optional Pressure Relief Kits feature a 175 psi pressure relief valve and trim v.,... Description components for convenient integration ...r.4, into commercial and residential riser The TYCO commercial and residential manifold assemblies. M1410 Model RM-1 Riser Manifold provide The pressure relief valve, installed in ( ,,r, the necessary waterflow alarm, res '-' sure gauge, alarm test orifice, drain, malmanifold assembliand n above the nodrain and sight glass equipment in a single valve,lcautomatically b eeds system assembly for use in NFPA 13 corn- Y. t�'.� mercial sprinkler systems and in NFPA flex ble hose exceeding ed 175 pto the si through nis- 13D/13R residential sprinkler systems fold drain outlet(Ref. Figure 5), reduc- wi as follows: ing system pressure to 175 psi. NFPA 13* • 1-1/2 Inch(DN40) NOTICE Male Thread x Female Thread The ModelIt RM-1 Riser Manifolds • 2-6 Inch(DN50-DN150) described herein must be installed Groove x Groove and maintained in compliance with this NFPA 13D document,as well as with the applica- • • 1 Inch(DN25) ble standards of the National Fire Pro- Fench(D read x Female Thread tection Association(NFPA),in addition 0 to the standards of any other authori- NFPA 13R ties having jurisdiction.Failure to do so • 1-1/2 Inch(DN40) may impair the performance of these Male Thread x Female Thread devices. `� • 2 Inch(DN50) The owner is responsible for main- Groove x Groove taming their fire protection system Although the Riser Manifold described in this techni- and devices in proper operating con- dition. Contact the installing contrac- tems, it may be used for NFPA 13D or 13R residential tor or product manufacturer with any sprinkler systems,where a test orifice of 2.8K or 4.2K is acceptable. questions. i 4,-% ii The variety of sizes and grooved end Technical connections allow cost effective and easy transition to check valves,control Data valves, and system piping. The Model RM-1 Riser Manifolds may be installed Approvals either horizontally(flow switch on top) UL and ULC Listed or vertically(flow going up)orientation, FM Approved for both single sprinkler rises and floor Listed by California State Fire Marshall control in high-rises. Maximum Working Pressure 300 psi(20,7 bar) Test Orifice 1-3 Inch(DN25-DN80)Manifolds:2.8K 4-6 Inch(DN100-DN150)Manifolds:4.2K Finish Red Painted • Page 1 of 8 FEBRUARY 2017 TFP963 TFP963 Page 2 of 8 • Nominal NO DESCRIPTION P/N Nominal Dimensions Drain 1 300 psi/2000 kPa Nominal End Inches Size Water Pressure Gauge..90050001 Riser Connections (mm) Inches 2 Test and Drain Valve, Size (DN) Model TD-1: Inches 1-1/2-3 Inch (DN) Inlet Outlet A B C D E F G H (DN40 -DN80) Size Manifolds, 1-1/2 Thread Thread 10 15-1/2 2-1/4 5-5/8 8-3/8 15 4-3/8 1-1/41-1/4",2.8K Orifice A61G0420 (40) MNPT FNPT (254) (394) (57) (143) (213) (381) (111) (32) 4-6Inch 2 13 18 2-1/16 5-5/8 8-3/8 15-1/4 4-3/8 1-1/4 Size 00-Dods (50) Groove Groove (330) (457) (53) (143) (213) (388) (111) (32) Size a Orifice A61G0601 2-1/213 18-1/16 2-1/16 5-5/8 8-3/8 15-1/4 4-3/8 1-1/4 3 Flow Switch,VSR-M: 91144815 (65) Groove Groove (330) (460) (53) (143) (213) (388) (111) (32) 1-1/2"(DN4o) 91144802/ 2"(DN50) 13 18-1/16 2-1/16 5-7/8 8-5/8 15-3/4 4-3/8 1-1/4 2-1/2"(DN65) 91144825 3 Groove Groove (330) (460) (53) (150) (219) (400) (111) (32) 3"(DN8o) 91144803 (80) 4"(DN100) 91144804 4 13 20-1/4 4-1/4 6-3/4 10-3/4 18-3/8 5-3/16 291144806 Groove Groove (330) (514) (108) (172) (273) (467) (132) (50) 6"(DN150) (100) 4 Field Replaceable 6 13 2(05-1-11t)4 1(/1-01/84) 7 3/4 1(-I3-0V 21 6-3/4 2 Retard/Switch 91144800 (150) Groove Groove (330) (197) (533) (172) (50) 1 OUTLET rif _._____. ." OPTIONAL /%r,'� �� PRESSURE I— �I OHNE TRIM CONNECTION T 11 O ) ■� ; III 3,4 11'iI - 2 i(IMO Irircril r,.r..�� 'r 0 vil I ail ice,, ' i, lid milLiT MN INLET C mom ra-.71 MIMI MI G H D E F FIGURE 1 MODEL RM- COMMERCIAL (DN4I ERM MANIFOLDS 1-1/2 • TFP963 Page 3 of 8 • OPTIONAL PRESSURE RELIEF TRIM 1"NPT CONNECTION (FEMALE)IN 1 min Numw be . '� r^� 2 =nom ■ NO DESCRIPTION P/N IH 10" 1 300 psi/2000 kPa •±� (254 mm) �,= t O ,...�_ 11" Water Pressure Gauge..90050001 lip �� * (280 mm) 2 Ball Valve,1"(DN25)....97111603 !�� ''-� 3 Flow Switch,VSR-M, �� �- 1"(DN25) 91144801 0 4 Field Replaceable 2-1/2" NPT iII Retard/Switch 91144800 _ (64 mm) DRAIN I 1 3-7/8" 3 3/4" (100 mm) (96 mm) F 1"NPT 3,4 4-5/8" (FEMALE) (118 mm) 10-1/8" (257 mm) FIGURE 2 MODEL RM-1 RESIDENTIAL RISER MANIFOLD • 1 INCH(DN25) OPTIONAL PRESSURE 1 RELIEF TRIM 1-1/2"NPT CONNECTION (FEMALE) /alit r 13-1/4" rr (337 mm) NO DESCRIPTION P/N 10 1 300 psi/2000 kPa (254 mm) Water Pressure Gauge..90050001 22 Ball Valve,1"(DN25)....97111603 3 Flow Switch,VSR-M, rilillisillimmil!,,,, 1-1/2"(DN40) 91144815 .... .... .....„ 7/16"(11 mm) 4 Field Replaceable ijI Retard/Switch 91144800 liwnvaliumisak 1 3-7/8" 3-7/8" (100 mm 1 (100 mm) 3,4 NPT 1-1/2"NPT 4-3/4" (MALE) DRAIN (121 mm) 11-3/8" (290 mm) ` F 3 GURE MODEL RM-1 RESIDENTIAL RISER MANIFOLD 1-1/2 INCH(DN40) TFP963 • Page 4 of 8 1 2" / - (GROOVED) MIMI Pffill- II- I- n /I%„ lit PRESSUREOPTIONAL t�1��``��/ RELIEF TRIM -40 CONNECTION -n16" am. 4 p (406 mm) NO DESCRIPTION P/N 1 300 PrkPa Water Pressure Gauge..90050001 ii pe 13"..... (330 mm) 2 Ball Valve,1"(DN25)....97111603 3 Flow Switch,VSR-M, 91144802 2"(DN50) ■ 4 Field Replaceable 2 It di Retard/Switch 91144800 2"mm) `.al 11.9111 ��� 3-7/8" 4-1/8" 3,4 (100 mm) 1" (105 mm) 2" NPT 5" (GROOVED) DRAIN (127 mm) 11-7/8" (300 mm) III FIGURE 4 MODEL RM-1 RE2S INCH(IAL BSER MANIFOLD Notes: Step 1. Install the manifold body with - Manifold the flow arrow pointing in the down- Where applicable pipe thread sealant m position using threaded con Installation is to be applied sparingly. Use of a strew ns and/or listed mechanical non-hardening pipe thread sealant istream s grooved connections,as applicable. TYCO Model RM-1 Riser Manifold recommended. Step 2.Connect the drain line and on must be installed in accordance with Never remove any piping component commercial manifolds set the Model this section. nor correct or modify any piping defi- TD-1 Test and Drain Valve to the OFF The Model RM-1 Riser Manifold may be ciencies without first depressurizing position or on residential manifolds installed either horizontally(flow switch and draining the system. close the drain valve. on top)or vertically(flow going up).The Provisions for an alarm test flow on Step 3. Refer to Figure 6 for wiring inlet of the Riser Manifold may be con- Residential Models must be made. guidance.All wiring must be performed netted directly to a shut-off control The alarm test flow is to be through in accordance with the authority having valve. an orifice having a flow capacity equal jurisdiction and/or the National Electri- to or smaller than the smallest orifice cal Code. sprinkler in the system. One of two Step 4. Refer to Figure 5 for Optional options can be considered. The first Step 4. Relief Trim Figure O option is to temporarily install a test n. orifice in the outlet of the drain line Step 5. Place the system in service prior to performing the alarm test. The by filling the system with water. When second option is to install an Inspec- filling the system, partially open the tor's Test Connection downstream of control valve to slowly fill the system. the Waterflow Alarm Switch. Filling the system slowly will help avoid damaging the waterflow alarm switch. After the system is fully pressurized, completely open the control valve. Step 6.Secure all supply valves open. • TFP963 Page 5 of 8 Commercial Riser Manifolds Residential Riser Manifolds NO DESCRIPTION P/N 1 Pressure Relief Valve, NO DESCRIPTION P/N - 175 psi,1/2"NPT 1001184-01 1 Pressure Relief Valve, 1001184-01 2 1/2"x Close Nipple 1001023-01 175 psi,1/2"NPT 3 Flexible Hose: MODEL RM-1 2 1/2"x Close Nipple,Qty 2...1001023-01 1-1/2-3leInch(DN40-DN80) COMMERCIAL 3 Flexible Hose,1/2"x 16"....1001266-03 Size Manifolds, RISER MANIFOLD 4 Figure 815 Threaded 1/2"x 24" 1001266-02 2 Reducing Tee, 4-6 Inch(DN100-DN150) 1 1"x 1"x 1/2"NPT Size Manifolds, 1001259-07 1/2"x 30" ���yy� � 5 1"x Close Nipple 1001025-01 1001266-01 `t 4 Figure 323 Reducing Tee, r Grooved x NPT Threaded: 1 (` MODEL RM-1 1-1/2-3 Inch(DN40-DN80) ` .�.� Size Manifolds, t' RESIDENTIAL 1-1/4"x 1-1/4"x 1/2" r�7�>' 7,l� RISER MANIFOLD 3231305GS ��/iW 4-6 Inch(DN100-DN150 ♦ 2 Size Manifolds, �� 1 2"x 2"x 1/2" 3232005GS / .:Niro'I 5 Figure 577 Rigid Grooved 4" �� 'ieS Coupling: 3Ali 1-1/2-3 Inch(DN40-DN80) 5 I Size Manifolds, q 1-1/4" 11; 'y4'r 57713AGCp '''"--7". �� �.�,, 4-6 Inch(DN1 -DN150) (j,; 111 Size Manifolds, 3 2" 57720AGCP 2 FIGURE 5 MODEL RM-1 COMMERCIAL AND RESIDENTIAL RISER MANIFOLDS OPTIONAL PRESSURE RELIEF TRIM INSTALLATION • Optional Commercial Manifolds Refer to Figure 1 for commercial riser Residential Manifolds residen- Pressure Refer features 1 and or Figure 5 for res- tial Refer to Figures 2, 3 or 4 for Relief Trim sure relief trim components describedri5 fors pressure ser orelief trim componld features and ents in this procedure. described in this procedure. Installation Step 1. Remove 1/2 inch pipe plug Step 1. Remove 1/2 inch pipe plug from manifold tee. Inspect exposed from manifold tee. Inspect exposed female tee threads,remove thread seal- female tee threads,remove thread seal- Model RM-1 commercial and resi- dential riser manifold assemblies are ant remnants or debris as necessary. ant remnants or debris as necessary. designed to accommodate an optional Step 2. Install Pressure Relief Valve(1) Step 2. Install Pressure Relief Valve(1) pressure relief valve and trim compo- in manifold tee, orienting valve outlet in manifold tee, orienting valve outlet nents(Ref. Figure 5). port perpendicular to and facing away port perpendicular to and facing away Optional pressure relief trim must be installed in accordance with the follow- from manifold body. from manifold body. ing procedures. Step 3. Install 1/2 inch x Close Nipple 9 Step 3. Disconnect drain piping from (2)in pressure relief valve outlet port. threaded outlet of manifold drai valve Notes: Step 4. Disconnect drain piping from as applicable and install 1 inch x Close For assembly in Riser Manifolds grooved outlet of manifold TD-1 test Nipple(5)in valve outlet. and drain valve as applicable and install Step 4. Install Figure 815 Reducing installed and in service, verify the fire Figure 323 Grooved Reducing Tee(4) Tee(4)onto 1 inch x close nipple,align- protection system is de pressurized and drained. Close the system supply on valve outlet by securing with Fig- ing tee branch outlet parallel with pres- control valve,set the system al manifold ure 577 Grooved Coupling (5), align- sure relief valve outlet port. Reconnect test and drain valve to DRAIN or open ing tee threaded branch outlet parallel drain piping to Figure 815 tee drain out- residential drain valve to relieve resid with pressure relief valve outlet port. let as necessary. ual pressure and drain system. Make Reconnect drain piping to Figure 323 certain that drainage water will not tee drain outlet as necessary. Step 5. Install 1/2 inch x Close Nip- cause any damage or injury. Note: Refer to Technical Data Sheet ples (2) in pressure relief valve outlet Refer to Care and Maintenance section //n port and in Figure 815 reducing tee G901 for Figure 577 Grooved Coupling branch outlet. for other requirements when closing a installation and assembly instructions.fire protection system control valve and Step 6. Install Flexible Hose (3) by placing system in service. Step 5. Install Flexible Hose (3) by threading female ends onto 1/2 inch x • threading female ends onto 1/2 inch close nipples installed on relief valve Apply thread sealant or TEFLON tape x close nipple installed on relief valve outlet port and Figure 815 reducing tee on all threaded connections, with the outlet port and onto Figure 323 reduc- branch outlet. exception of internally sealed flexible ing tee branch outlet. Note:Assure Fhose connections. Note:Assure Flexible Hose is not sus- ceptible to being Hose orsnagt ceptible to being caught or snagged by other moving equipment. gedd agbsuby other moving equipment. TFP963 Page 6 of 8 • SWITCH TERMINAL CONNECTIONS CLAMPING SEVERED UNINSULATED PLATE STRIPPED CAUTION: TERMINAL ENDS LOOPED SECTION An uninsulated section of a � � SEPARATE \ SINGLE single conductor is not �� CONDUCTORS CONDUCTOR permitted to be looped around ..i the terminal and serve as two INCOMING CLAMPING /\� separate connections.The PLATE ���`\\`\ wire must be severed to serve �`;;� TERMINAL _ as two separate connections, �i�` thereby providing supervision of the connection in the event ``�'' that the wire becomes dislodged from the terminal. OUTGOING PROPER CONNECTION METHOD IMPROPER CONNECTION METHOD FIRE PANEL OR WIRE NUT LOCAL WIRE NUT ADDRESSABLE AUDIBLENISUAL MODULE ANNUNCIATOR rillaNallNEUTTAL WHITE WHITE BLACK F ccw 2u.i �_O U m BLACK F 7 q (LINE/HOT) O w z J ODZ J Q Q ___ 0 • 11111!. ... Illomm...... CONTACT RATINGS: 111111 Two sets SDT125(Form CC)10.0 Amps at 0VDC esis 2.0 Amps at in.at Resistive ,10 mAmps min.at 24VDC r- - � � �� NOTE: Q Q QWhen tedcontrolng tp a Ea UL Listed control panel, use panel resistor rating r rfor circuit supervision NOTE: For supervised circuits,see"Switch Terminal Connections"above.The Waterflow Alarm Switch has two switches,one can be used to operate a central station,proprietary or remote signaling unit,while the other contact is used to operate a local audible or visual annunciator. FIGURE 6 MODEL RM-1 COMMERCIAL D RESIDENTIAL GUIDANCE RISER MANIFOLD WIRING °The TFP963 Page 7 of 8 DRAIN ) A ��OagOFF`,L'O ale -10 0 0 smt-0 yNjjD1531OFF MARKING TEST MARKINGON HANDLE ON HANDLE DRAIN MNRKING POSITIONED POSITIONED ONO HANDLD ON DETENT ON DETENT POSITIONED ON DETENTCNN �rJ' ( �'! MEDT AND, h/ �� •MIRAN r,-_' DRAIN ��'=�r awl.-miff OO-. ��O 0,, VALVE Mil 4 11100 FLOW7CSGHT{._ O •= eno _ 111 Ill IIIDRAINSET TCONNECTIONCONDITION EST DRAINCONDITION CONDITION FRONT FIGURE 7VIEW MODEL RM-1 COMMERCIAL RISER MANIFOLD TD-1 TEST AND DRAIN VALVE OPERATION Care and standards of any authority having juris- of the NFPA,and any impairment must diction.Contact the installing contrac- be immediately corrected: Maintenance for or product manufacturer with anyTYCO Riser Manifolds RM-1 must be questions. Alarm/Flow Test Procedure sYvOeR andser Manifolds in accmust be It is recommended that automatic Drai 1.Place the Model post TestRed with this section. sprinkler systems be inspected,tested, Drain Valve in the TEST position (Ref. and maintained by a qualified Ins ec- withou 7). Ost rfice, em rasly insall Before closing a fire protection systemtion Service in accordance with local without a test orifice,temporarily install control valve for inspection or main requirements and/or national codes. a test orifice in the drain outlet and fully tenance work on the fire protection Note: No attem t is to be made toopen the Dgge wa er willl not cacertain system that it controls, permission to repair any Riser Manifold componentthat dgeior injury. shut down the effected fire protection in the field. Onl the ressure au a damssystem must first be obtained from waterflow alar switch, or relief vale Step 2.Verify operation of associated the proper authorities and all person- can be rep/aced.If any other prob/emsalarms. nel who may be affected by this action are encountered the entire riser mani- P Verif that the residual (i.e., must o notified. Ste 3. yAfter placing a fire protection s stem fold must be replaced. flowing)pressure indicated by the pres- Aservice, ngtay the proecr ontsysti m result In opeThe low tet p oe educe wd recsuro gaugo is eno ste that originally p recorded for the system when it was in and advise those responsible for moni- alarms. Consequently, notificationfirst installed. toying proprietary and/or central station must be given to the owner and the fireStep 4. Close the Drain Valve on the alarms. department, central station, or otherResidential models and the Test and owner is responsible for the signal station to which the alarms are inspection,testing,and maintenance of connected, and notification must be Drain valve on commercial models. their fire protection system and devices given to the building occupants. Step 5. Verify that the static (i.e., not in compliance with this document, as The following inspection procedure sureflowing) ge is no less that originally well as with the applicable pressure indicated by the pres- sure au of the National Fire Protection standardsa must be performed as indicated, in recorded for the system when it was tion e. addition to any specific requirements first installed. ( g., NFPA 25), in addition to the TFP963 Page 8 of 8 Optional 175 psi Pressure Relief Kit Specify: Pressure Relief Kit, Model Limited Ordering RM-1 Riser Manifold,(specify Commer- Procedure tial or Residential application),(specify Warranty size range),P/N(specify): For warranty terms and conditions,visit Contact Whenlocal placing ranutorder,avail- di- CommeciaN4o DNBo) 40721 www.tyco-fire.com. cate the full product name, including 1-1/24-8 -3 3h Inch(DN40-DN80) 40731 description and part number(P/N). Residential Riser Manifolds 1-2 Inch(DN25-DN50) 40711 Specify:Size(specify)Connection Type (specify inlet x outlet)Model RM-1 Riser Replacement Model Part 1 Riser Manifold s Manifold,P/N(specify): (specify part description), P/N(specify Commercial 40551 from Figures 1,2,3,4 or 5) 1-1/2 Inch(DN40)MT x FT 40601 2 Inch(DN50)G x G 40611 2-1/2 Inch(DN65)G x G 40621 3 Inch(DN80)G x G 40651 4 Inch(DN100)G x G 40661 6 Inch(DN150)G x G Residential 40671 1 Inch(DN25)FT x FT 40571 1-1/2 Inch(DN40)MT x FT 40591 2 Inch(DN50)G x G I • GLOBAL HEADQUARTERS 11400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 „�„l��� Copyright VICO Protection Products ri a ©2017 Tyco Fire Products,LP. All rights reserved. TEFLON is a registered trademark of DuPont ,fir *} s4f�1,y > *.. SIF "1.. ''' es {�r, ' C. t� }J� r ( t t As the leading supplier of steel sprinkler pipe,we understand that there are no second chances in fire suppression.You need products of enduring quality and exceptional strength-plus reliable service.You need Bull Moose. Bull Moose Fire Sprinkler Pipe Product Information Nominal Pipe Size(Inches) 1' 1-1/4" 1-1/2" 2" 2-1/2" 3" Min) a• 1.660 1.900 2.375 2.875 3.500 4.500 1.530 1.728 2.203 2.705 3.334 4.310 .$ ' Empty Weight(hb/tfj • 1222 1.844 2.330 2.809 3.361 4.968 » n ' Water Filled Weight(lb/ft) 2.019 2.860 3.982 5.299 7.144 11.290 C. .R.". 1.98 3.44 2.78 1.66 1.00 1.00 Pieces per Cif[ 61 61 37 30 ",_ - Lift Wgight(Ibsk21;dengths ' 19 19 • 1,565 2,362 1,810 1,770 1,341 1,982 Lift Weight(Ibs).24,lengths 1,789 2,700 2,069 2,022 1,533 2,265 Lift Weight(lbs)25'lengths 1,864 2,812 2,155 2,107 1,596 2,360 EDDY FLOW ADVANTAGES: - OTHER BENEFITS/SERVICES: UL listed(US&Canada)and FM approved . • .. • We have the most stocking locations in the industry, ' • ASTM A135 and.A795 Type E;Grade A Certified for best delivery and availability • Complies with NFPA=13,13R and 14 • Plain end or roll groove. • Industry-leading hydraulic characteristics • Eddy Guard II"bacterial-resistant internal coating • CRR of 1.0 and greater • Custom length options • All pipe NDT weld tested • Hot dipped galvanization • Reddi-Pipe®red or black pipe eliminates field painting • Compatible for use in wet,dry,preaction and deluge Exclusive maker of Reddi-Pipe® sprinkler systems RED OR BLACK PAINTED PIPE. • The only maker with EPDs(to help earn LEED points). GCERTIFIEDN COU$LISTED ® Cil 4 °Arm APPROVED A• .�. ..•,..w.......-.,....., 1442., 44 1 •1 bb f y BULL lti/[OOSE® s ° ,I TUBE .; BallMooseTube.com ,r as **' ' i.M. it o . . 44 SCHEDULE 10 8 40 , , ,,., ,..„ ** ,3/4..,..„..... * �' •- .., , ., 11,,,,,,,...„..0 , ,,, • ', .s ,.11 (3t)- e V A �tf'',1 C } ,U , 3 5 ... ,:.,...*._„1/4.;.140,-, , ,, '40* 40 ti* - **4''''''' . . , "''''' "s'''.-4,' < ' *104 4 r , • . IP` ;0*'r,. ..* to 5,. . t ' 3 4 eS �6 E t 1r �.: i, � i, ' � M� _. t �` �Ai L � 3 '- r t. _. _ .. \ .. , .. . C ond chances in fire As the leading supplier of steel sprinklerexceptionale srength—plus reliable serviceerstand that there are no .You need Bull Moose. Bull and need products of enduring quality Bull Moose Fire Sprinkler Pipe Product Information Nominal Pipe Size(Inches) 1" 1-1/4" 1.1/2" 2" 2-1/2" 3" 4" 6" 8" NPS On.) 1" 1-114" 1-1/2" 2" 2-1/2" 3" 4" 40 0.0.On) 1.315 1.660 1.900 2.375 2.875 3.500 4.500 6.625 8.625 1.315 1.660 1.900 2.315 2.875 3.500 4.500 R 'I.D:(in) 1.097 1.442 1.682 2.157 2.635 3260 4260 6357 8.249 Ov 1.049 1.380 1.610 2.067 2.469 3.068 4.026 F 1.680 2.210 2.720 3.660 5.800 7.580 10.800 €.mpty Weight(Ib/ft) 1.410 1.810 2.090 2.640 3.530 4340 5.620 9.290 16.940 iWater Filled Weight(Ib/ft) 1.820 2.518 3.053 4.223 5.893 1.951 11.196 23.038 40.086 � 2.055 2.918 3.602 5.114 7.875 10.783 16316 _ 0 1.00 1.00 1.00 1.00 1.00 1.00 1.00 C.R.R. 15.27 9.91 7.76 6.27 4.92 3.54 2.50 1.158 1.805 G - W 10 51 44 30 30 19 19 W Pieces per Lift 91 61 61 31 30 19 19 10 1 2,470 2,431 2,513 2,306 3,654 3,024 4,309 = Lift Weight(lbs)21'lengths 2,695 2,319 2,617 2,051 2,224 1,132 2,242 1,951 2,490 u Mf A 2,822 2,178 2,872 2,635 4,176 3,456 4,925 Lift Weight(lbs)24'lengths 3,079 2,650 3,060 2,344 2,542 1,979 2,563 2,230 2,848 2,940 2,894 2,992 2,745 4,350 3,601 5,130 Lift Weight fibs)25'lengths 3,208 2,760 3,181 2,442 2,648 2,062 2,610 SCHEDULE 10 0 40 ADVANTAGES: OTHER BENEFITS/SERVICES:SERVICES . • UL listed(US&Canadaaaa)and FM approved • We have the most stocking locations,in the industry, for best delivery and availability` • ;ASTM A135 and A795 Type E,Grade A Certified plain end or roll groove . - ` • Complies with NFPA-13,13R and 14, • Eddy Guard.II-bacterial-resistant internal coating •. Industry-leading hydraulic characteristics • Custom length options , • CRR of 1.0 and greater • Hot dipped galvanization • All pipe NDT weld tested • Reddi-Pipe®red or black pipe eliminates field painting • Compatible for use in wet;dry,preaction and deluge sprinkler systems Exclusive maker of Reddi-Pipe® • The only maker,with EPDs(to help earn LEED points). RED OR BLACK PAINTED PIPE. CERTIFIED CC)US LISTED ® C;) � 0,.......NFm....”....„r,,. • . , APPROVED '••'•"''••°�Pri .. -- 1444 . / . to i i ' i ' BULL. �1/[OOSE• BullMooseTube.com TUBE . SIDE WINDER® FOR WOOD -Horizontal Application Application Product Features " I , E Not less than 2"nominal width •No pre-drilling required. (1-1/2")up to 3-1/2"pipe;not less than 3"(2-1/2")nominal width 4"&5"pipe . -......... ............,.•10111101.0 Iliplip......11 ..)! Quick to install using the Sammy ---- . . .. ,. _ Floor Joist Nut Driver with an 18V cordless IMinimum 2-1/2"from bottom for _...._._1* sdrill/drivtier. branch lines.Minimum 3°from bot- tom for main lines.Exception This • ayes me fromtraditionalweal requirement shall not apply to 2°or methods. 4J thicker nailing strips resting on top of steel beams. . _ , , •Reduces installation costs. _ . 111 • eill) 1 •Made in the U.S.A. I Composite!Truss I Consult truss manufacturer for • ,•••-,-‘'- -'• ..' . Pre-drilling may be required for Model 1 SWG 25-38a Tool available on page 11. / t UWatch a video demonstraton) Mil qr.? wwwitwbuildex.com Lui LU Rod Part Screw Ultimate UL Test Box Case Approvals . Model Size Number Descriptions Pullout(lbs) Load(lbs) Qty Qty 0 HORIZONTAL MOUNT • 1/4" ,,.._ ,801,9957 SWG 200 ,.,1 1/4 x 2" ,,,,,, , 1725 (Fir) ,,,Saves time e4rom traditi 25 1 methods125„ ., V.4"'$74 k 4 ::118; : 7 80007# f 77* Om 1,9: ;7 7. 7 1/4,tx$7,:7' 7 ,,..§4(Fir4 7:7* .444*41' 17 "'al ' , 125 3/8" 8021957 SWG 20 1/4s 2" 1725 (Fir) 1050 25 125 4" 16'473 ,t- *87.4 A AA :AM.057 ''''' * *V 0.24-4$AA: '''' lilk Z --..f.„:44,..41725 4904444.,..1*: ,4Eg:l: ''''" 7 2 ,iit. 3/8"* 8022925 SWG 25-380 3/8 x 2-1/2" 2249(Fir) 1500 25 125 ....,.:4,... #14 SW Red 1-:-,*'--.., l' 4 % A, A 'NW A A A 8023925 ' ''''.1 ..S100t- At - ' 'I'M iS"k A A 1884;4.01-1, „ : A. ,,,,,, ''''., .'',-- 4.:, 25 4- 125 Nut Driver Part#8114910 *May require pre-drilling;consult joist manufacturer 4J Ct SAMMYS SWIVEL HEADTM FOR WOOD -Swivel Application 0 , z Application Product Features : 0 0 WOOD JOIST SH.G..T20 •Eliminates distortion of threaded rod. OR RAFIER * \ •Accommodates up to 3 W x 12 pitch roof. ' •=—.---- - *' - •Allows 17°deflection from vertical. (0) LU: it jo, •Reduces installation costs. ce I •Made in the U.S.A. 0 HANGER rr‘. MAX ANGLE 89° (#).. . CO .. Rod Part Model Screw Ultimate UL Test Load FM Test Min Box Case 1,4 Approvals Number Descriptions Pullout(lin) (lbs) Load(lbs) Thickness Qty Qty 41) SWIVEL MOUNT Size 0 , . #14 Black E4.•<> 3/8" 8139957 SH-GST 20 1/4 x 2" 1257(Fir) 1050 1475 25 125 ICC 4 ! Nut Driver - ,..„.=,.., ;,„, ., -- 144 - -Nts-r- bt. i/4,0„,„ , (,-) u , ,, , , b.0-, . .. . ., Part#8113910 •-air.--2- - .:=3/0 -- 8 957 4 -.,,,..S a - x 4 ,-1720 Fir . - 15 , 1475 . - ....25 - 125- 1903 Dim.Lumber 1500 ,Et. 3/8" 8269957 SH-GST/CST 20 5/16 x 1-3/4" 1406 @45°off vertical 0„„,,c., 25 125 Dim.Lumber '-'"u CO r; 9031,Ditit.Lu`tillaq': . - ' " 4 ''' ' ; ''''' : : , , ., ..1 111/ , ,4 .„ t,,,, ,,, lIZ:,-,839457: ,,SktfGarT/GSTg.2,0" ,5/15)(.1-3/4"4 ,1406 6 45*c*yertisal. .1" ":`: -fr1 '4: .4 2 ' '11. : ' ' ',,, 25' r:125 . cr , .,, ,,„ , „ , ,, r -,,,,, . ' '--1.,, ,,,, ,, Dim.LUmber , , = =., lllMIIIlll11"l11IlIlllll--- mmM..M.....Tl..M.11I°I.Iil.II..I.l1...IIll1llllIII: ,,,,i4 sH a.ange "May require pre-drilling;consult joist manufacturer. C) Nut Driver flt E'ql-t#5273910 - 4 4. 'ct 5 To find a distributor near you,call 800-BUILDEX t SAMMYS® FOR WOOD • SAMMYS° FOR WOOD - Vertical Application Product Features Application 111 Not less than Wood Flooring •No pre-drilling required. 2"nominal width 4(1-1/2")), m •Quick to install using the Sammy ro Nut Driver with an 18V cordless Not less man drillldriver. 3°nominal ` thickness ") Wood Joist (depthorr side") •Saves time from traditional �l. of vertical member) ) methods. mssimmolleromswielmimmilw 'V Double Sheetrock Ceiling •Reduces installation costs. For ve tical use- $i install.in center of lower face. ` •Made in the U.S.A. Mn mutit e um 2'embedment l plio base Composite i Truss S: material for NEPA 13 compliance . Consult truss manufacturer for recommended installation point 'pre-drilling may be required the GST 25-380.Toof avarfabre on page if Watch a video demonstration at vytyry.ihybuifdex.comm Rod Part Screw Ultimate UL Test FM Test Box Case ApprovalsSize Number Model Descriptions Pullout(lbs) Load(lbs) Load(lbs) Qty Qty VERTICAL MOUNT 210(7116"OSB) 114" 8002957 GST 100 1/4 x 1' 25 125 670 (314'Ply) w GST 20Q "1 v •1780 iry # 2 • 125'` �, '"114v. # 25 125 114 8004957 GST 300 1l4 x 3 2060 (Fir) • vre v 210(• 7!�€z S } • .x 25 r2 • 18s 800795T> a• GS T0 114 x 1 670144 P s rie Ar sl • • • . 31)0 850 xs 1iss 475 25 125 • 318' 8008957 GST 20 114 x 2' 1760 (Fir) . ; 25 • X25 > k r /8 a•t 2 GST 0 S, ,' 147 2"" 160(F>F} .v ,q85@ , • �- „ , 1500 25 125 CC 318' 8009925 GST 25 380 318 x 2-112' 2113(Fir) 25 � 125 r #14 Black 3 .s . 8010957 '' - GST 30 r1141 3" 206th(k ) '' ',':1,0644 25 125 Nut Driver 318 8069925 GST 30 SS 1/4 x 3" 2060(Fir) Pad#8113910 c3f � x - 2 a` 125'' 7. 1 925,, • GST40 -. b,s11. 21:.a(F5r):, 25 125 112' 8013925 GST 2 114 x 2" 1760 (Fir) • 25 125 . • • • li • • ,i s' •, , • ,a .. it 1t , ;301#9 5 GS 2,,&' 0 • /$x 2-112"'„ _. 711 ( 11 25 125 112" 8015925 GST 3 1/4 x 3" 2275 (Fir) #14 SW Red Nut Driver Part#8114910 MADE INa°F (.0 SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into • contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. For the most up to date information,visit www.itwbuildex.com 4 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 300 , 0 §0 RING HANGER NFPA 13 UL PIPE ROD 1 N7F 540 75 0 TEST LOAD � 1 3/8 30.76 403.75 750 11/4 3/8 43.95 469.75 750 11/2 3/8 54.15 520.75 750 • 2 841 2 3/8 76.95 75 750 1/2 3/8 118.35 841.75 850 1 thru 4 inch pipe 1/2&3/4 inch pipe 3 3/8 162.30 1061.50 1050 LISTED FOR STEEL/CPVC 5 thru 8 inch pipe q 3/8 246.00 1480.00 1500 5 1/2 349.45 1996.75 2000 6 1/2 476.35 2631.75 2650 8 1/2 711.00 3805.00 4050 SIZE-ROD-3/8"or 1/2" SIZE-SYSTEM PIPE- 1/2"thru 8" MATERIAL-Carbon Steel. FINISH-Mil.Galvanized to G-90 specification. LISTING/APPROVAL- °®'"203-EX 2551 1"-8" F" Approval guide-1"-8" OSHPD OPA-0601 See Website. Conforms to Federal Specification WW-H-171E type 10,and Manufacturers Standardization Society SP-69,type 10. MAXIMUM TEMPERATURE-650°F. FUNCTION-Pipe component of an AFCON hanger. To support horizontal steel,CPVC or copper pipe. INSTALLATION-Per these instructions including NFPA 13 and the CPVC manufacturers instructions. FEATURES PIPE A *Sized and listed exclusively for use with#310 Surge Restrainer. 8793 2.5259 r „/4 2.,382 2]850 4\1/ Band edge is offset for EASY pipe insertion. � „/2 2.26,3 2.9,46 *Custom fit swivel nut for better retention in ring. A s 2 2.6048 35080 ORDERING-Part#,pipe size. 1 2ia 2.,500 3.5080 3 38625 3.8205 • 4 3.5625 4.3205 5 4.0940 4.9397 6 4.6250 5.4707 8 7.5620 8.4077 0 tin 9/15 $ ,Z177ge . P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 077 ATTACHMENT FITTING LOCKING 17/32" ‘1111111V 110 a 077S STEEL BASE PLATE SIZE-BRACE PIPE: 1" and 1 1/4" Sch.40 MATERIAL-Carbon Steel or S.S.(Type 304). FINISH-Plain or E.G. LISTING/APPROVAL- '®"203A-EX2625 <>FM Approved-1950 OSHPD See Website. LISTED FUNCTION-Structure attachment fitting of an AFCON sway brace assembly. INSTALLATION-Per these instructions including NFPA 13 or FM 2-8. Load rating-see chart. ASSEMBLY Combine with proper AFCON components-see disclaimer below. cOus Max. Horizontal Load Insert brace pipe thru fitting near pivot bolt. Tighten set bolt until head contacts bracket. 30°thru 90° 2015 FEATURES * Swivel allows attachment at any angle. © Max.ASD Horizontal Load *Visual inspection,verifies proper installation. F *Larger fastener hole available.-Consult factory. 30°-44° 45°-59° 60°-74° 75°-90° ORDERING-Part#,size-brace pipe and finish. 630 870 I 1620 1810 FASTENERS Be advised A FCON products are exclusively designed apply DISC [ible ONLY with other AFCON products including parts and fasteners,resulting in a listed sway brace,restrainer or hanger assembly. • comp st e failure of its roducts n used in noet manufacturedloor sold warranty reswiction will ECON.AFCON shall NOT beliableDISCLAIMER deer anyFCOu ns an ess whatsoever foill NOT warrant r anyhdirect or indirect,ineldental or eonseque tial damages of any kind, nation with other inolding but,parts or not . limited to loss of business or profit,when non-AFCON products have been,or are used. , 5/15 • :, • goo P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 410 SWAY BRACE FITTING Part#077..E //— ,.\ — ,.\ \� \ Part#078 IP tit Part#410 — (11 • SIZE-SYSTEM PIPE:Nominal Pipe Size Sch.40 Steel 1" thru 8" Sch. 10 Steel 1 1/4"thru 8" MATERIAL-Carbon Steel FINISH-Plain or E.G. Horizontal Load Ratings LISTING/APPROVAL- Size UL 1"-4" 1000 c®ua 203A-EX 2625 6"-8" 2015 '41ED 203-EX 2551 (4"-8" Only) OSHPD OPA-0601 See Website. FUNCTION-Longitudinal fitting of an AFCON sway brace assembly. Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. INSTALLATION- Per NFPA 13 and these instructions. Load rating-see chart. Align brace pipe parallel to system pipe. ASSEMBLY-See drawing. Combine with proper AFCON components-see disclaimer below. Align brace member parallel through 410 bolt flanges. Tighten bolts to 40 ft. lbs. ORDERING-Part#,size-system pipe and finish. OP • - • Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners,resulting Be advised the following warranty restriction will apply. DISCLAIMER-AFCON will NOT warrant against the failure of its products when used insteco bin tion with other pproducts, hanger assembly.orsystems not manufactured or sold by AFCON.AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect,incidental or consequential damages of any kind,including but nou limited to loss of business or profit,when non-A FCON products have been,or are used. 5/12 o � P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 001/020 SWAY BRACE FITTING MODEL E 1 Part#077 CI - � c �I'.�..,. ,`• ��' 4 4:-.*:, 7...tte e.„ it........, Q SIZE-SYSTEM PIPE: Nominal !S> Max.ASD Horizontal Load Steel 1"thru 4" Sch. 10 and Sch.40 SIZE-BRACE PIPE: 1"or 1 1/4" Sch.40 System Sch. 30°-44° 45°-59° 60°-74°75°-90° ` NPS 430 610 750 840 MATERIAL-Carbon Steel or S.S.(Type 304). j" 40 FINISH-Plain or E.G. 1 1/4"-1 1/2" LW-40 90 130 160 180 ��� l w LISTING/APPROVAL- 2" 10 550 790 960 1080 7-3" 40 500 710 870 970 <>FM Approved-1950 2 1/2"-4" i w 160 230 280 320 21/2"-4" 10 2600 37 0 40 60 5190 0 OSHPD See Website. 4" 40 FUNCTION- Lateral fitting of an AFCON sway brace assembly. INSTALLATION-Per these instructions including NFPA 13 and FM 2-8. Load rating-see chart. ASSEMBLY-See drawing. Combine with proper AFCON components-see disclaimer below. Insert brace pipe through rod bend and under channel bracket to achieve minimum 1"extension. Tighten hex nuts until gage spring lays flat or torque to 165 lb-in. FEATURES *Visual inspection,verifies proper installation. ORDERING-Part#,size-system pipe,size-brace pipe and finish. • Beai c AFCON products are exclusively e tr c ion designedpp bey.compatible DISC LAMER-AFCON will NOT warrantwith other A FCON ts including againstt the ffailure of itrts and steners,resulting in a listed sway brace,restrainer or hanger products when used in combination with other products,partssor ystems - ne advised the followingor sowarranty N.AFC N l apply. not manufactured or sold by AFCON AFCON shall NOT be liable under any circumstances whatsoever for any director indirect,incidental or consequential damages of any kind,including but not limited to loss of business or profit,when non-A FCON products have been,or are used. < 7., -$. 8/14