Loading...
Plans (6) BUP2017 - 00012 DEMOLITION PLAN LEGEND KEY PLAN OX DESIGNATED BY THIS SYMBOL 1. SHADED WALLS INDICATE WALLS TO REMAIN. TAKEN'SAKE PIZZA Ken McCracken, 4 2. EXISTING CEILING GRID TO BE MODIFIED PER SHEET A2.0. Architect Architecture•Program Management•Permitting 7 1L 3. PREPARE EXISTING FLOOR FOR NEW FINISHES. -- 4. DASHED LINES INDICATE WALLS TO BE REMOVED. 16219 SE 12th STREET \ / SUITE 202 5. REMOVE EXISTING DOOR AND FRAME;SAVE AND PROTECT FOR REINSTALLATION. SEEN0TVANCOUVER, WA 98683 �A 5 > SHEET A1.0. Contact: Martin D. Lakey - 6. EXISTING LIGHTS TO BE REMOVED. (360)719-1952 7. EXISTING PLUMBING FIXTURES TO BE REMOVED,SEAL AND CAP ABANDONED UTILITIES. r• , " ' ken.mccracken@comcast.net 7 SEE SHEET P 1.0. 4f i TAKEWBAKE PIZZA VIA 1 � . Q . ill ����*D A � ; � � KENNETH J. DEMOLITION GENERAL NOTES C� JAN 23OFTIUA D M RACK -------_---� r___-_------- 1. DEMOLITION CONTRACTOR RESPONSIBLE FOR VERIFICATION OF ALL D BUILDING DIVISION AM S,WA MATERIALS AND CONSTRUCTION OF ALL FLOOR,WALL,CEILING AND ROOF ,yYr license#5599 \ ASSEMBLIES. r r �jA o\ 2. DEMOLITION CONTRACTOR TO SURVEY THE CONDITION OF THE BUILDING TO 9JF OF DETERMINE WHETHER REMOVING ANY ELEMENT MIGHT RESULT IN A STRUCTURAL VICINITY DEFICIENCY OR UNPLANNED COLLAPSE OF ANY PORTION OF THE STRUCTURE OR ADJACENT STRUCTURES DURING SELECTIVE DEMOLITION. 01/18/17 3. EXISTING CONSTRUCTION THAT IS TO REMAIN SHALL BE PROTECTED FROM DAMAGE AS REQUIRED DURING DEMOLITION OPERATIONS.ANY DAMAGEKJM/1434 CAUSED BY THE DEMOLITION SHALL BE REPAIRED AT THE EXPENSE OF THE / / ITV, DEMOLITION CONTRACTOR. / (( \� / Seal 7AKE'N'BAKE PIZZA 4. DEMOLITION CONTRACTOR IS RESPONSIBLE TO MAINTAIN THE CONSTRUCTION FIRE ASSEMBLY RATING FOR ALL EXISTING RATED WALL ASSEMBLIES, ROOF ASSEMBLIES AND/OR SHAFTS. a 5. EXISTING UTILITIES TO REMAIN IN SERVICE AND PROTECT THEM DURING SELECTIVE rns DEMOLITION sw raves Metxg r b. CONDUCT DEMOLITION OPERATIONS AND REMOVE DEBRIS TO ENSURE MINIMAL INTERFERENCE WITH ROADS,STREETS,WALKS AND OTHER ADJACENT OCCUPIED ra m AND USED FACILITIES.REMOVE AND TRANSPORT DEBRIS IN A MANNER THAT WILL PREVENT SPILLAGE ON ADJACENT SURFACES AND AREAS. PROMPTLY DISPOSE OF '°"'"" Store ALL DEMOLISHED MATERIALS. NOT ALLOW DEMOLISHED MATERIALS TO C # OR 130 ACCUMULATE ON SITE. LEGALLYLY TRANSPORT AND DISPOSE OF ALL DEMOLISHEDMATERIALS. 7. PROVIDE TEMPORARY WEATHER PROTECTION,AS REQUIRED, DURING SELECTIVE \t DEMOLITION AND CONSTRUCTION PROCESS TO ENSURE THAT NO WATER DAMAGE OCCURS TO STRUCTURE, EQUIPMENT, EXTERIOR OR INTERIOR AREAS. \� ® ° 11705 S Pacific Hwy , Su � te Z117U1 soutl,w.a � ��P+dfictlighwry ®DEMOLITION SHALL BE PATCHED TO MATCH EXISTING ADJACENT SURFACES s O sqUNLESS CONCEALED BY NEW CONSTRUCTION. Z 9. ALL EXISTING CABINETRY,COUNTERTOPS,SHELVES, ETC.IN AREAS OF DEMOLITION " '� �mR s O � G� SHALL BED PATOREMOVED, FLOOR AS REQTHATUIRED FOR ALL NEW PLUMBING. ON DRAWINGS. ev dao 4 Tigard u y Tigard , OR 9w CO D 10. CUT AND PATCH FLOOR AS REQUIRED FOR ALL NEW PLUMBING.CAPABANDONED MECHANICAL BELOW PATCH OF FLOOR SLAB. 9 _w NORTH11. VERIFY ALL MODIFICATIONS OF PLUMBING WITH PLUMBING DRAWINGS. 44 w 12. THOROUGHLY CLEAN BUILDING UPON COMPLETION OF SELECTIVE DEMOLITION. vy4�s .° &` _ O 13. TOTAL SCOPE OF DEMOLITION MAY NOT BE COVERED IN THESE PLANS, REVIEW w DEMOLITION PLAN 1 Q ALL SHEETS IN THE CONSTRUCTION DOCUMENTS AND COORDINATE WITH OWNER Oregon. U = m 1/8"=1'-0" I (, TO DETERMINE TOTAL SCOPE OF DEMOLITION. F,n Temple-The-Thecnurcn... C uck Park {;� t NO W GENERAL NOTES DRAWING SYMBOLS CODE ANALYSIS PROJECT CONTACTS SHEET INDEX N N 0 1. CONTRACTOR SHALL VERIFY AND COORDINATE ALL DRAWINGS AND REPORT PROPERTY INFORMATION: BUILDING CODES Ao.o COVER SHEETTtt ANY DISCREPANCIES TO THE ARCHITECT FOR CLARIFICATION AND (� - COLUMN GRIDLINE & BUBBLE O.S.S.C. (2014) EDITION WITH AMENDMENTS FRANCHISER A0.1 ACCESSIBILITY PLANS RESOLUTION PRIOR TO PERFORMING ANY WORK. DISCREPANCIES AMONG PACIFIC CROSSROADS O.S.P.C. (2014) EDITION WITH AMENDMENTS IL A0.2 ACCESSIBILITY DETAILS THE DRAWINGS OR BETWEEN THE DRAWINGS AND THE SITE CONDITIONS DO _ DTL# APN:- PAPA MURPHY'S COMPANY STORES, INC. NOT QUALIFY AS GROUNDS FOR COMPENSATION FROM THE OWNER, SHT# DETAIL OR ENLARGED PLAN MARKER O.S.M.C. (2014) EDITION WITH AMENDMENTS 8000 NORTHEAST PARKWAY DRIVE,SUITE 350 A1.0 DIMENSION FLOOR PLAN AND SCHEDULE FRANCHISER OR DESIGN PROFESSIONALS FOR ERRORS IN BUILD-OUT OR O.S.F.C. (2014) EDITION WITH AMENDMENTS VANCOUVER, WASHINGTON 98662 A2.0 REFLECTED CEILING PLAN INSTALLATION. _ O.S.E.0 (2014) EDITION WITH AMENDMENTS PHONE NO.: (360) 260-7272 J A2.1 FINISH PLAN AND SCHEDULE 2. DO NOT SCALE THE DRAWINGS. DTL# O.E.E.S.C. (2014) EDITION WITH AMENDMENTS FAX NO.: (360) 260-0500 SHT# ELEVATION INDICATION A3.0 INTERIOR ELEVATIONS 3. CONTRACTOR IS TO VISIT SITE PRIOR TO BID SUBMISSION AND COMPARE OWNER-OF-RECORD & PRIMARY CONTACT A4.0 DETAILS DRAWINGS AND SPECIFICATIONS TO EXISTING CONDITIONS AND BE Xo-- WALL TYPE INDICATION EQ 1.0 EQUIPMENT PLAN KNOWLEDGEABLE OF ALL WORK BEING PERFORMED. IV JERRY KENNEY EQ1.1 EQUIPMENT AND DECOR SCHEDULES 4. ALL WORK SHALL CONFORM TO THE LATEST ADOPTED ISSUES OF ALL 24794 SW 65TH AVE Q REVISION MARKER TUALATIN, OR 97062 } APPLICABLE CODES AND LOCAL REGULATIONS. BUILDING SUMMARY PHONE NO.: (503) 970-5700 E1.0 FLOOR POWER PLAN D 5. ALL NEW WORK SHALL BE IN COMPLIANCE WITH FEDERAL, STATE, AND LOCAL 00 NOTE MARKER-REFER TO CONSTRUCTION TYPE: V-B piaapride.jk@gmail.com E2.0 LIGHTING PLAN L/) (o REGULATIONS. DRAWING LEGEND (NON-SPRINKLERED) Q ACV E3.0 ELECTRICAL RISER AND SCHEDULES Eq (y) CV 6. ALL DIMENSIONS ARE INSIDE ROOM CLEAR DIMENSIONS, UNLESS NOTED TOTAL AREA UNDER THIS PERMIT: 1784 SF \ r � OTHERWISE. I WALL BLOCKING/ BACKING OR FINISH TOTAL BUILDING AREA: ±40,000 SF ARCHITECT crrYOFTIGAIiD I� = p" MARKER MIA MECHANICAL PLAN FOR CODS COMPLIANCE a U 7. CONTRACTOR SHALL PROVIDE ALL NEEDED BLOCKING FOR ATTACHMENT OF NUMBER OF STORIES: 1 KEN McCRACKEN, ARCHITECT Approvc& Q O 4= 0 ALL WALL-HUNG ITEMS. ACCESSIBLE PATH OF TRAVEL OCCUPANCY GROUPS: M VAN O VTR ST.,SUITE 202 UU1L 8 44-- 8. 'U O VANCOUVER, WA 98683 P1.0 PLUMBING PLANS 8. ANY/ALL SITE WORK AND/OR LANDSCAPE DESIGN IS BIDDER-DESIGNED PHONE NO.: (360) 719-1952 Permit#t © O AND IS NOT THE RESPONSIBILITY OF THE FRANCHISOR OR ARCHITECT. DR # DOOR/WINDOW NUMBER FAX NO.: (360) 719-1955 Address: \ PROJECT MANAGER:MARTY LAKEY +- 2 9. EXTERIOR SIGNAGE SHALL FALL UNDER A SEPARATE SUBMITTAL. ROOM Suite#: \ N J NAME ROOM NAME& NUMBER-REFER TO C/) XXX ROOM FINISH SCHEDULE By. Date: L0 10. ALL EXISTING BUILDING INFORMATION IS BASED UPON INFORMATION Z t /) RECEIVED FROM PAPA MURPHY'S INTERNATIONAL, INC. OR STORE OWNER. V .Y117�, ,PAa[a O� THE ARCHITECT SHALL NOT BE HELD RESPONSIBLE FOR THE ACCURACY OF XX EQUIPMENT MARKER THESE EXISTING CONDITIONS. O NOTE MARKER-REFER TO NATE: OFFICE COPY 11. IT DIS THE GENERAL CONTRACTOR'S RESPONSIBILITY A COORDINATE WITH DRAWING LEGEND DISCLAIMER DECOR SUPPLIER FOR INFORMATION FOR BIDDING AND INSTALLATION OF THERE ARE NO HAZARDOUS MATERIALS STORED OR USED AT THIS FACILITY IN EXCESS ITEMS SUPPLIED IN THE DECOR PACKAGE. OF THOSE LISTED ON CHARTS 307.1(1) AND 307.1(2) OF THE 2014 O.S.S.C. 12. DEMO WORK MAY NOT BE SHOWN IN PLANS. CONTRACTOR SHALL ABBREVIATIONS SCOPE O F WORK NOTICE TO FRANCHISEE FOR THIS LOCATION: COORDINATE WITH OWNER AND RECONCILE WITH PLANS TO DETERMINE SCOPE OF DEMO WORK. THESE PLANS HAVE BEEN PREPARED TO DEPICT A COMPLETE,TRUE-TO-STANDARDS (AS TENANT IMPROVEMENT INTO A TAKE N' BAKE PIZZA STORE. (NO COOKING FOR SALE INVOLVED) LANDLORD THEY EXIST ON THE DATE OF THE PLANS) "PAPA MURPHY'S TAKE'N' BAKE PIZZA SHOP". F.O.W. FACE OF WALL WORK INCLUDES NEW FLOORING AND WALL FINISHES, PLUMBING AND ELECTRICAL ROUGH-IN THE PLANS HAVE BEEN DRAWN BASED UPON LEASE INFORMATION AND A WORKING R. F. I . PROCEDURES F.O.B. FACE OF BLOCK WYSE INVESTMENT KNOWLEDGE OF BUILDING CODES AND PRACTICES. HOWEVER, EXACT COMPLIANCE Project Number FOR NEW EQUIPMENT AND PLUMBING FIXTURES. F.O.F. FACE OF FINISH KATHI PEARCE WITH CODES IS NOT REPRESENTED OR GUARANTEED BY PAPA MURPHY'S F.O.S. FACE OF STUD OR STOREFRONT THIS SET OF PLANS TO BE ON JOB SITE AT ALL TIMES DURING CONSTRUCTION. NO CHANGES OR PHONE: (503) 294-0400 INTERNATIONAL, INC.. BUILDING CODES VARY IN VARIOUS JURISDICTIONS. IT IS THE PPM 16049. 1 A.F.F. ABOVE FINISHED FLOOR REVISIONS TO THE APPROVED PLANS OR SPECIFICATIONS SHALL BE PERMITTED UNLESS SUBMITTED ALL REQUESTS FOR INFORMATION SHALL COME DIRECTLY FROM THE GENERAL REF, REFER TO TO AND APPROVED BY THE BUILDING OFFICIAL.THE ISSUANCE OF A PERMIT SHALL NOT PREVENT STORE OWNER'S RESPONSIBILITY TO MAKE SURE THE DRAWINGS CONFORM TO THE B.O. BOTTOM OF THE BUILDING OFFICIAL FROM REQUIRING THE CORRECTION OF ERRORS OR OMISSIONS FROM SPECIFIC REQUIREMENTS OF THEIR LOCAL JURISDICTION. CONTRACTOR TO THE ARCHITECT.SUB-CONTRACTORS SHALL NOT CONTACT THE THE APPROVED PLANS AND SPECIFICATIONS. Sheet Name TOP OF ARCHITECT OR ENGINEERS DIRECTLY.THE GENERAL CONTRACTOR SHALL COPY T.O.T.O. VERIFY THEREFORE, PAPA MURPHY'S INTERNATIONAL. INC.ACCEPTS NO RESPONSIBILITY OR THE STORE OWNER AND PAPA MURPHY'S PROJECT MANAGER ON ALL V.I.F. VERIFY IN FIELD LIABILITY FOR THE USE OF THESE PLANS OR OTHER DATA FURNISHED BY PAPA MURPHY'S CORRESPONDENCES. EC ELECTRICAL CONTRACTOR PROJECT VALUATION$110,000. INTERNATIONAL. INC. RELATIVE TO THIS PROJECT. THE STORE OWNER IS HEREBY GIVEN GC GENERAL CONTRACTOR INTERIOR DESIGN PACKAGE EXTERIOR SIGNAGE PERMISSION TO USE THIS INFORMATION FOR BIDDING AND CONSTRUCTION, AND TO COVER SHEET PC PLUMBING CONTRACTOR FSE FOODSERVICE EQUIPMENT SUPPLIER PROVIDE THIS INFORMATION TO ARCHITECTS, ENGINEERS,AND CONTRACTORS AS SEPARATE PERMITS KING RETAIL SOLUTIONS EVERBRITE JUSTIN GRISHKIN PROJECTS IN TEXAS &WEST OF TEXAS MAY BE NECESSARY TO SECURE A BUILDING PERMIT, CONSTRUCT THE IMPROVEMENTS, PI PLUG-IN CONNECTION (800) 533-2796 KLYE FRYE AND OBTAIN A CERTIFICATE OF OCCUPANCY. PROVIDE SUPPLY AND INSTALL AS REQUIRED ADJUSTMENTS TO THE FIRE ALARM AND THE FIRE PROTECTION SYSTEMS,IF REQUIRED,ARE TO BE 414.529.7190 A COPY OF THE BUILDING PERMIT AND CERTIFICATE OF OCCUPANCY IS REQUIRED TO AND IN COMPLIANCE WITH ALL COMPLETED BY A QUALIFIED FIRE ALARM AND/OR FIRE PROTECTION CONTRACTOR, UNDER FIXTURES/EQUIPMENT/SMALL WARES BE PROVIDED TO PAPA MURPHY'S INTERNATIONAL, INC. APPLICABLE CODES, BUILDING CONTRACT TO THE STORE OWNER. OWNER SHALL CONTACT LANDLORD REGARDING LANDLORD CURTIS RESTAURANT EQUIPMENT PROJECTS EAST OF TEXAS CONDITIONS AND OWNER PREFERENCES OR REQUIREMENTS FOR FA/FP CONTRACTORS AND/OR SYSTEMS. FA/FP DRAWINGS, SHAUN RELKEN Sheet Number BRIAN HUTCHESON REQUIREMENTS IF REQUIRED,ARE TO BE PROVIDED BY THE FA/FP CONTRACTOR UNDER A SEPARATE SUBMITTAL RI HUTCH 414.529.7278 AND WORK SHALL BE COORDINATED WITH THE GENERAL CONTRACTOR ( ) OWNER PAPA MURPHY'S STORE OWNER OR SUPPLIER UNDER NO CHANGES OR REVISIONS TO THE APPROVED CONSTRUCTION A 0 0 CONTRACT TO OWNER PAPA MURPHY'S IS CARRY-OUT TRI-MARK DOCUMENTS ARE TO BE MADE WITHOUT THE EXPRESSED WRITTEN ONLY AND DOES NOT COOK KIM NOVAK CONSENT OF PAPA MURPHY'S INTERNATIONAL/ • PIZZAS FOR SALE (800) 729-5367 CONSTRUCTION DEPARTMENT OCCUPANCY LOAD CALCULATIONS ROOM AREA (S.F.) OCCUPANT LOAD FACTOR OCCUPANCY LOAD —~ LOBBY 328 15 22 PREP AREA $07 200 5 Ken McCracken, �\ UTILITY (W/H, WASH/DRYER) 30 TRANSIENT USE N/A Architect Architecture•Program Management•Permitting R ESTROOMS 4$ 100 1 \\ 16219 SE 12th STREET FRONT LINE 393 200 1 2 SUITE 202 I OFFICE 48 100 1 VANCOUVER, WA 98683 � .,� , CIRCULATION 47 N/A N/A M X, ._ ACCESSIBLE PATH Contact: Martin D. Lakey ('---- - -- TO PUBLIC WAY (360)719-1952 ------------------ ----------- _ * E ken.mccracken@comcast.net I I - " TOTAL 1,701 (1)l I 31 I I I I I I I LL'VEL AREA I I I JI { 1. GROSS SQUARE FOOTAGE OF SPACE AS DEFINED BY THE INTERIOR FACES OF THE BUILDING I \ I UNISEX WALLS AND DEMISING WALLS. INCLUDES ALL OCCUPIABLE AREAS, INCLUDING AREAS OF I I RESTROOM I I 30x48 CIRCULATION. I I 106 I I 11 _ — I --- _I \ / \E A C I — 1 I j I I I A0.1 1 \ / I �ED ARo CD 1 I ! I I I 160 D I NOT PART ! I I �/ I KENNETH J. I I 1 .{ 4 M RACKS ,. I I L------ -� ° \ I ' I -----J • \ I L-__ _____--__7_-- - -- AM S,WA V I � O� License#5599 _- OF 0 EXIT WIDTH/NUMBER CALCULATIONS �- ' i MANAGER 01118117 / 103 NUMBER OF EXITS PER I.B.C. (2006) EDITION ' �� KJM/1434 I NUMBER OF EXITS REQUIRED TOTAL PROVIDED Seal / LOBBY/FRONT LINE: M OCCUPANCY WITH OCCUPANT LOAD OF 1 TO 49= 1 1 � PREP AREA: M OCCUPANCY WITH OCCUPANT LOAD OF 1 TO 49= 1 ' PREP AREA OVERALL EXIT WIDTHS PER I.B.C. (2006) EDITION 102 c TOTAL EXIT WIDTH REQUIRED TOTAL PROVIDED ' ® CE— LOBBY/FRONT LINE: 34" 24 X .2=4.9" (32"MIN.) ' I PREP AREA: I 34" I II I J 7 X .2= 1.4" (32"MIN.) I I ' I > ILIJ ca c I.- co 1 rn cn �\ w W NORTH ® LU LU °- >Y u u r LL:L—u_J� LZLI Q COOLER ;r=-=r�=,; W ZD ENLARGED RESTROOM PLAN 1/2"=1'-0" _ `° 11 10' x 20' UJ IE it II FI r co FIRE / LIFE SAFETY COTES `` " " '` Cq C LL tt_u J� � N N \ �r=�s==rt �� O 1. PROVIDE MINIMUM 2A-10B-C RATED FIRE EXTINGUISHERS LOCATED WITHIN A 75-FOOTFE TRAVEL DISTANCE FROM ANY POINT IN THE BUILDING ON EACH FLOOR LEVEL. EXTINGUISHERS SHALL BE MOUNTED ON THE WALL OR IN CABINETS,SUCH THAT THE TOP OF THE EXTINGUISHER IS NO MORE THAN FIVE (5) FEET ABOVE FLOOR LEVEL. Lh 2. EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANYVv SPECIAL KNOWLEDGE OR EFFORT. MANUALLY OPERATED EDGE OR SURFACE MOUNTED BOLTS ARE PROHIBITED. B 3. PROVIDE APPROVED PANIC HARDWARE ASSEMBLIES ON ALL REQUIRED EXIT DOORS - ELEVATION — A ELEVATION - (DEAD BOLTS, LATCHES, LOCKS, AND SIMILAR DEVICES SHALL NOT BE INSTALLED ON B ANY DOOR WHICH IS PROVIDED WITH A PANIC HARDWARE ASSEMBLY).SEE FLOOR FRONT LINE % --"^'-"--`— PLAN AND DOOR SCHEDULE ON SHEET A1.0. P2 4. PROVIDE,MAXIMUM OCCUPANCY SIGN OVER MAIN DOOR(S) (SIGNS SHALL BE POSTED a ❑� ❑� IN A CONSPICUOUS LOCATION NEAR THE MAIN EXIT OR EXIT-ACCESS DOORWAY FROM R6 P2 THE ROOM). V) R8 5. PROVIDE APPROVED EXIT SIGNS INSTALLED AT ALL REQUIRED EXITS AND WHERE I >,,,N LU OTHERWISE NECESSARY IN ORDER TO INDICATE THE DIRECTION OF EGRESS. NO POINT 1 M } N R2 � SHALL BE MORE THAN 100 FEET FROM THE NEAREST VISIBLE SIGN. EXIT SIGNS SHALL BE � ? R5 INTERNALLY OR EXTERNALLY ILLUMINATED.SEE CEILING PLAN ON SHEET A2.OFOR `\ ° G�=' (�/ E U LOCATIONS. Q O c� --- !! •-- � W3 6. EMERGENCY LIGHTING, ILLUMINATING THE PATH OF EXITS SHALL BE PROVIDED PER " 8 z GOVERNING CODES. ' L W3 �� p R3L- LL O Q� a 7 o ' LOBBY r I I t/) � 0 B2 62 LEGEND � ELEVATION — C ELEVATION — D o _----- MN. r--, I I CLR I LEVEE I 60"BY 60"MIN.CLEAR FLOOR SPACE AT EXTERIOR OF DOOR. I I `AREA, MAXIMUM SLOPE OF 2.0%IN ANY DIRECTION. I \E P2 P2 = I ACCESSIBLE PATH OF TRAVEL (MIN.36"CLEAR WIDTH) 7 !J 0 I A4.0 19 " R6 I R7 'DEL AREA � Project Number R5 R2 PPM16049. 1 TACTILE EXIT SIGN LOCATION,SEE DETAIL 5/Ao.2. I I I ACCESSIBLE PATH I I TO PUBLIC WAY OINTERNATIONAL SIGN OF ACCESSIBILITY LOCATION, Sheet Name SEE DETAIL 6/AO.2. 1 W3 p51 W3 A4.0 ACCESSIBILITY PLANS B2 62 NOTES: NORTH Sheet Number 1. SEE SHEET AO.2 FOR ALL REQUIRED FIXTURE DIMENSIONS. 2. SEE SHEET EQ1.1 FOR RESTROOM ACCESSORY FIXTURE SCHEDULE. NOTE:SEE REFLECTED CEILING PLAN AND LIGHTING PLAN FOR EMERGENCY LIGHT FIXTURES A • UNISEX RESTROOM ELEVATIONS 3/$"=1'-0" AND EXIT SIGNS. EGRESS PLAN 1/4"=1'-0" 4 4'-5" EMBLEM MUST BE LOCATED IN STALL SO THAT IT IS VISIBLE BY A TRAFFIC 1/2"RADIUS 8" DOOR NOTES: 3'-9" ENFORCEMENT OFFICER WHEN A VEHICLE IS PROPERLY PARKED IN THE FLOOR FINISH TO BE FLUSH OR 1. ALL EXIT DOORS SHALL BE PIVOTED OR 48"MIN. 18" BLUE Z.8 1/2" SPACE (CENTERED AT ENTRANCE TO STALL RECOMMENDED.) MEET SLOPE STANDARDS FOR SIDE HINGED SWINGING TYPE. 8"MIN. 17" RAISED CHARACTERS TRANSITIONS AS SHOWN ON 25"MAX. - WHITE ° 1. SIGNAGE AND IDENTIFICATION OF SPACES: BOTH SIDES. 2.THE MINIMUM SIZE FOR ANY DOOR MIN. SHALL BE 3'-0"x6'-8"AND SHALL HAVE A PARKED IN UNAUTHORIZEDVEHICLES2. EACH ACCESSIBLE PARKING SPACE TO HAVE PERMANENT 2 MINIMUM OF 32"CLEAR, SIGN z �, Ken McCracken, PARKED IN DESIGNATED - ACCESSIBLE SPACES NOT DISPLAYING �' (70 SQ. IN.) REFLECTORfZED PORCELAIN ENAMELED STEEL 1 X 0 U 8"MIN. DISTINGUISHING PLACARDS REFLECTORIZED SIGN 1/2"MAX. cr" z `� F-- ¢ X Architect OR LICENSE PLATES PARKING SIGN, FREE STANDING SIGNS LOCATED IN A PATH OF 3. ALL DOORS SHALL HAVE A LEVEL FLOOR ISSUED FOR PERSONS CONSTRUCTED OF ONLY AT 1:2 SLOPE OR LANDING ON EACH SIDE OF THE ° o 0 0 X `'� m "" z z "� WETOWABILRlES - TRAVEL SHALL BE MOUNTEDAMIN. OF80"ABOVE � p � � L` Architecture�ProgramManagement�PernTttin N MAY BETOWEDAWAYA7 p 11"MIN. g OWNERS EXPENSE. PORCELAIN STEEL DOOR NOT TO EXCEED A MAXIMUM OF � �t 0 „ TOWED VEHICLES MAY BE b �r WALKING SURFACE.WALL MOUNTED SIGNS LOCATED AT 1/4 MAX. 1/4"PER FOOT OR 2%. RECLAIMED AT WITH BEADED TEXT BLUE N (Address) INTERIOR END OF PARKING SPACE SHALL BE MOUNTED A LZ 16219 SE 12th STREET 1z Xi OR BY TELEPHONING OR EQUAL WALL MOUNTED SIGN 4.A MINIMUM BOTTOM RAIL OF SOLID FLAT _ (Telephone Number WHITE MIN. OF 36"ABOVE FINISH GRADE. -- - - -- SURFACE SHALL BE A MINIMUM 10"(NO GRADE 2 BRAILLE (CENTER OR LEFT JUSTIFY) _ SUITE 202 APPROPRIATE INFO. THRESHOLD GLAZING PERMITTED). TOP EDGE OF BRAILLE AT 60"MAX.AFF. a0 CLEAR FLOOR 6"MAX. z_ VANCOUVER, WA 98683 3. OFF-STREET PARKING FACILITIES TO HAVE SIGN AT EACH BOTTOM EDGE OF BRAILLE AT 48"MIN.AFF. SPACE MUST BE INCLUDED ENTRANCE OR IMMEDIATELY ADJACENT TO OR VISIBLE o ON SIGN (MIN. OF 1" INTERNATIONAL � PROPORTIONS- 5.DOUBLE DOOR WIDTH SHALL BE 3'-O" Contact:Martin D. Lakey IN HEIGHT). SYMBOL OF SURFACE IDENTIFICATION FROM EACH STALL OR SPACE NOT LESS THAN 17"x22 IN NOMINAL OPENING (ACTIVE LEAF). CHARACTERS ON SIGNS$HALL BE RAISED 1/32"MIN.AND HAVE A WIDTH TO HEIGHT RATIO (360)719-1952 SIZE.SIGN TEXT TO BE BEADED (OR EQUAL}. COMPRESSED OF BETWEEN 3:5 AND 1:1 AND A STROKE WIDTH TO HEIGHT RATIO OF BETWEEN 1:5 AND ACCESSIBILITY{N - ken.mccracken@comcast.net LETTERING ON SIGN VAN ACCESSIBLE SIGN CARPET 1/4"MAX. FINISH FLOOR b NO REVOLVING DOOR ALLOWED FOR 1:10. THE MINIMUM CHARACTER HEIGHT SHALL BE 3 INCHES AND SANS-SERIF UPPER CASE. LAVATORY NOTES: 0 WHITE ON BLUE .4SIGN TEXT TO STATE THE FOLLOWING:"UNAUTHORIZED 0o MUST BE A MIN. OF BELOW THRESHOLD ACCESSIBLE DOORS. 1"IN HEIGHT BACKGROUND PARKING NOTE: EVEN 0 1. PROVIDE A CLEAR SPACE 30"x48"MIN. IN FRONT OF THE LAVATORY. THE CLEAR SPACE ONLY VEHICLES PARKED IN DESIGNATED ACCESSIBLE SPACES THRESHOLD .o 36" SIGN TO BE CENTERED AT THE DOOR HARDWARE NOTES: MAY EXTEND INTO KNEE AND TOE SPACE UNDER LAVATORY. � NOT DISPLAYING DISTINGUISHING PLACARDS OR LICENSE GRADE 2 BRAILLE DOTS SHALL BE 1110'ON CENTER IN EACH CELL WITH 2110"SPACE PAV D SURFACE MINIMUM INTERIOR END OF PARKING SPACE. PLATES ISSUED FOR PERSONS WIRH DISABILITIES MAY BE 1.DOORS SHALL BE OPERABLE FROM BETWEEN CELLS, MEASURED FROM THE SECOND COLUMN OF DOTS IN THE FIRST CELL TO 2. INSULATE OR CONFIGURE HOT WATER SUPPLY AND DRAIN PIPING UNDER LAVATORIES TO IDENTIFICATION FINE$2,% SINGLE EFFORT, NO GRASPING OR WRIST PREVENT CONTACT. AREA OF SIGN TO BE A MINIMUM TOWED AWAY AT THE OWNER'S EXPENSE.TOWED VEHICLES MOVEMENT USING LEVERS, PUSH-PULLS THE FIRST COLUMN OF DOTS W THE SECOND CELL.DOTS SHALL BE RAISED A MINIMUM OF FINISH SURFACE VAN ACCESSIBLE OF 70 SQUARE INCHES. MAY BE RECLAIMED AT OR BY TELEPHONING OR PANIC DEVICES, AND SHALL BE 1/40"ABOVE THE BACKGROUND. 3. NO SHARP OR ABRASIVE ELEMENTS ARE ALLOWED UNDER LAVATORIES. EFFORT TO OPERATE DOORS: "FILL IN BLANK SPACES WITH APPROPRIATE OPENABLE WITHOUT USE OF A KEY OR 4. FAUCET CONTROLS AND OPERATING MECHANISMS ARE REQUIRED TO BE OPERABLE WITH 80"MINIMUM TO DESIGNATE FOR"VAN ACCESSIBLE" INTERIOR DOOR=5 POUNDS ANY SPECIAL KNOWLEDGE OR EFFORT. SIGNS SHALL BE INSTALLED ON THE WALL ADJACENT TO THE LATCH OUTSIDE THE DOOR. ONE HAND AND CANNOT REQUIRE GRASPING, PINCHING, OR TWISTING OF WRIST. THE FREE STANDING WHEN APPROPRIATE. WHERE THERE IS NO WALL SPACE ON THE LATCH SIDEINCLDO ENTRY DRIVEWAY SIGNAGE INFORMATION A$A PERMANENT PART OF THE SIGN. D�� , INCLUDING DOUBLE LEAF DOORS, FORCE REQUIRED TO ACTIVATE CONTROLS IS NOT TO EXCEED 5 LBS. LEVER OPERATED, CONTACT LOCAL JURISDICTION FOR APPROPRIATE . EXTERIOR DOORS= 5 POUNDS 2.HARDWARE SHALL BE MOUNTED AT 8O"MIN. FOR INFORMATION. FIRE DOORS= 15 POUNDS 38"-44"HIGH. SIGNS SHALL BE PLACED ON THE NEAREST ADJACENT WALL, PREFERABLY TO THE RIGHT. PUSH TYPE AND ELECTRONICALLY CONTROLLED MECHANISMS ARE EXAMPLES OF WALL MOUNTED MINIMUM 3.DOOR CLOSERS SHALL PROVIDE A ACCEPTABLE DESIGN. FINE$250 MINIMUM OF 3 SECONDS TO MOVE 5. SELF CLOSING VALVES ARE ALLOWED IF THE FAUCET REMAINS OPEN FOR AT LEAST 10 KENNETH J. 5. SIGNS SHALL BE LOCATED CURB SIDE SO THAT A 24" LV TO TOP OF OVERHANG OF A PARKED VEHICLE SHALL NOT DAMAGE IT. FROM A 70 DEGREE OPEN POSITION SECONDS. M ACK WALKING SURFACE TO A POINT 3"FROM THE LATCH. FINISHED FLOOR TYPICAL ACCESSIBLE PARKINSIGNAGE 13 DOORS 9 EXIT SIGNS 5 VUI `AMe#,SwA C � 3/4"=,'�' 6"=1'-0" ,"=1'-0' LAVATORIES R I ES 3/4„=,'-0" �, PREDOMINANT DIRECTION CLEAR ANY AMOUNT 3'-0"MIN. EXTERIOR HAZARDS: C C QFl. ABRUPT CHANGES IN LEVEL EXCEEDING 4!'[N LONG DIMENSION PERPENDICULAR TO OF TRAFFIC WIDTH VERTICAL HEIGHT,SUCH AS AT PLANTERS, 01118/17 ROUTE OF TRAVEL 1/2"MAX. FOUNTAINS OR FOUNDATIONS LOCATED IN OR ADJACENT TO WALKS,SIDEWALKS, OR 48"MIN. OTHER PEDESTRIAN WAYS, REQUIRE WARNING r 14" KJM/1434 - � CURBS AT LEAST 6"HIGH ABOVE THE WALKING & MIN. PROJECTION 0 SURFACE. NO CURB IS REQUIRED IF A Seal v SURFACE A GUARDRAIL IS PROVIDED,CENTERED 3"PLUS o o --_---___-- 17" r) CE OF RAMP � - OR MINUS 1"ABOVE SURFACE OF WALK OR - MAX. PROJECTION C;7 1z 4.r SIDEWALK. `"� GRATING SECTION MAX. i o / qt�- �_ -_ - NOTES: i ``J 0 1 OBJECTS PROJECTING FROM WALLS WHOSE 10 GRATING NOTES: i� � iI O / N J MC14 LEADING EDGES ARE BETWEEN 27"AND 79" -----------� 1. WALKS,SIDEWALKS, AND PEDESTRIAN WAYS SHOULD NOT HAVE GRATINGS. ,Y ABOVE FINISH FLOOR CANNOT PROTRUDE 12" HORIZONTAL PROJECTION OF RUN 12" MORE THAN 4' INTO WALKS AND HALLS. V� ♦ _ X 2. WHERE GRATINGS OCCUR IN ANY OTHER PATH OF TRAVEL,THE GRID OPENINGS ARE 2.OBJECTS WHOSE LEADING EDGES ARE AT OR 9 V V <t REQUIRED TO BE NO GREATER THAN 1/2"IN THE DIRECTION OF TRAFFIC FLOW. BELOW 27"ABOVE FINISH FLOOR MAY 1 ]/W'TO PROTRUDE ANY DISTANCE, BUT MAY NOT T 9 DEPTHAT PRIVACY URINAL 1 1 J2 REDUCE THE REQUIRED CLEAR SPACE. SCREEN IF CLEAR SPACE IS 1 1/2 PROTECT SHADED AREA 3.FREE STANDING OBJECTS ON POSTS OR LESS THAN 30"WIDE WALKS AND SIDEWALKS NOTES: (MAY VARY ACCORDING TO STATE LAW) FROM CROSS-TRAFFIC PYLONS MAY OVERHANG 4"MAX. FROM 27"TO 79"ABOVE FINISH FLOOR AND HAVE URINAL NOTES: 1: PRIVATE WALKS OR SIDEWALKS ARE REQUIRED TO BE ACCESSIBLE IF THEY LEAD TO BUILDINGS t AND FACILITIES REQUIRED TO BE ACCESSIBLE. CANE DETECTION A RADIUS CORNER OF/s'". AREA 1.AT EVERY PRIMARY PUBLIC ENTRANCE AND AT EVERY MAJOR JUNCTION ALONG OR LEADING 1. PROVIDE STALL-TYPE OR WALL HUNG URINALS WITH AN ELONGATED RIM AT MAXIMUM 77 4.WALKS, HALLS,CORRIDORS, PASSAGEWAYS, TO AN ACCESSIBLE ROUTE OF TRAVEL,THERE SHALL BE A SIGN DISPLAYING THE INTERNATIONAL z ALLOWABLE RAMP LENGTHS 2. MINIMUM WIDTH:48". AISLES OR OTHER CIRCULATION SPACE SHALL SYMBOL OF ACCESSIBILITY.SIGNS SHALL INDICATE THE DIRECTION TO ACCESSIBLE BU[LD1NG HEIGHT 17". FLUSH CONTROLS TO BE HAND OPERATED AND MEET SAME REQUIREMENTS AS 0 _, ¢ HAVE 80"MINIMUM CLEAR HEAD ROOM. ENTRANCES AND FACILITIES. FLUSH CONTROLS OF TOILET AND TO BE NO MORE THAN 44"ABOVE FLOOR. ¢ :2 MAXIMUM MAXIMUM HORIZONTAL 3. WALKS AND SIDEWALKS SHALL HAVE CONTINUOUS COMMON SURFACE, NOT INTERRUPTED BY w m SLOPE % RISE PROJECTION STEPS OR BY ABRUPT VERTICAL CHANGES IN LEVEL EXCEEDING 1/4!'. LEVEL CHANGES BETWEEN n? FLOORS: 2.WHEN A BUILDING CONTAINS AN ENTRANCE OTHER THAN THE MAIN ENTRANCE WHICH IS 2. ALTHOUGH NOT EMPHASIZED IN REGULATIONS,THE ACCESSIBLE WALL HUNG URINAL , m 1/4"AND 1/2"ARE BEVELED A MINIMUM OF 1:2. �o l,FLOORS OF A GIVEN STORY ARE A RAMPED OR LEVEL FOR USE BY DISABLED PERSONS, A SIGN SHOWING ITS LOCATION IS SHOULD BE MAXIMUM ELONGATED RIM TYPE IF AVAILABLE. N 1:12 8.33% 30 INCHES 30.0 FEET ry COMMON FLOOR LEVEL THROUGHOUT, REQUIRED TO BE POSTED AT OR NEAR THE MAIN ENTRANCE. 1:15 6.67% 30 INCHES 37.5 FEET UNLESS CONNECTED BY CONFORMING w W 3.PROVIDE SIGNS WITH INTERNATIONAL SYMBOL OF ACCESSIBILITY INDICATING LOCATION OF 3. WHERE URINALS ARE PROVIDED AT LEAST ONE SHALL HAVE A 30"x48"MIN.CLEAR SPACE IN c� 1:16 6.25% 30 INCHES 40.0 FEET 4. SURFACES WITH SLOPE OF LESS THAN 6%GRADIENT SHALL BE SLIP-RESISTANT. RAMPS, ELEVATORS OR OTHER ACCESSIBLE > Lu a- 1:20 5.00% 30 INCHES 50.0 FEET MEANS OF VERTICAL ACCESS. EACH ACCESSIBLE ENTRY. PROVIDE ADDITIONAL DIRECTIONAL SIGNS AS REQUIRED. FRONT OF URINAL. UJ a- O 5. SURFACE CROSS SLOPES SHALL NOT EXCEED 2%AND 5%IN THE DIRECTION OF TRAVEL. INTERIOR HAZARDS 2.ALL FLOORS SHALL BE SLIP RESISTANT. 4.MAT CARPETING MUST BE SECURELY ANCHORED TO FLOOR OR RECESSED INTO DOOR LANDING. z � o w ¢ HANDRAIL AT RAMP 1/4"=1'-0" 1 $ WALKS, SIDEWALKS & ROUTES 6"=V-0" 14 HAZARDS 1/8"=V-0„ 10 ENTRY SIGNS 1/4" 6 URINALS 3/8"=V-0" 2 ^ 000 39"-41" ACCESSIBLE PARKING STALL NOTES VERTICAL GRAB o IF SLOPE OF RAMP IS BAR N O BETWEEN 5%AND 6.67%, 1. ACCESSIBLE SPACE MUST PERMIT USE OF EITHER CAR DOOR WITH AN UNLOADING z THE RUNNING PORTION AREA ON THE PASSENGER SIDE. TWO-ROLL PAPER ACCESSIBLE OF THE RAMP MUST 2. WHEELSTOPS ARE REQUIRED WHEN NO CURB OF BARRIER IS PROVIDED OR FACES � HOLDER WITHOUT ¢ SIGN,SEE DETAIL HAVE A DETECTABLE OF BUILDINGS,SIGNS OR OTHER OBJECTS CAN BE DAMAGED. STOPS. 12"MAX. 1 1/4"TO 1 1/2" � NOTE: IF X IS LESS THAN FROM TOILET TO WARNING SURFACE 54"MlN, 13/A0.2 3. WHEELCHAIR USERS MUST NOT BE FORCED TO TRAVEL BEHIND PARKED CARS OTHER 48"THEN THE SLOPE OF FRONT OF OUTER 36"MIN. 1 112" PRODUCT THAN THEIR OWN. 42 MIN. PAPER ROLL DISPENSER MIRROR 4. SURFACE SLOPES OF PARKING AREAS FOR THE DISABLED SHOULD BE MINIMAL AND THE FANNED OR FLARED GRAB BAR ARE REQUIRED TO NOT EXCEED 2%IN ANY DIRECTION. SIDE MAY NOT EXCEED MAX. MAX. TOWEL& HAND 5. RAMPS SHALL NOT ENCROACH INTO ANY PARKING OR UNLOADING SPACE. 1:12 (8.33%)• AATRASH DRYER 2'-0"OR 6. ACCESSIBLE SPACES SHALL BE AS CLOSE AS POSSIBLE TO ACCESSIBLE PRIMARY 24" 12" LESS ENTRANCE TO FACILITY. OSL it WHEN PROVIDED, FACE OF 7. WHEN ONLY ONE SPACE IS PROVIDED, 1T IS TO BE DESIGNED AS A VAN ACCESSIBLE �� NOTE:CROSS SLOPE OF `� - --� ° MIN MIN. SEAT X WHEEL STOP 2'-0"OR BLDG. OR SPACE. p���G�\O� LANDING AREA DOES 17"_19" M COVER Z (a:] LESS FROM CURB STRUCTURE 8. A 36"CLEAR ROUTE IS REQUIRED BETWEEN AN ACCESSIBLE PARKING SIGN AND THE ��� NOT EXCEED 2%IN ANY TO TOP OF DISPENSER BUILDING IT SERVES. 0`' o•7 7 o �g 9. PROVIDE 6"HIGH WHEELSTOPS OR BOLLARDS WHERE NO RAISED CURB EXISTS AT 0 DIRECTION TOILET EAT w Cl) N ACCESSIBLE PARKING SPACE. 36"MAX. PARKING SPACE 10. THE NUMBER OF ACCESSIBLE PARKING STALLS PROVIDED IS TO BE IN ACCORD WITH P ' _ 18" EMBLEM,SEE TABLE 11 B-6. 1 OF EVERY 8 ACCESSIBLE STALLS PROVIDED IS TO BE DESIGNED AS e GRAB BARS: TOILET ACCESSORIES: •� DETAIL 13/A0.2 12„ �.�°M ql WARNING DOMES 1, LOCATE GRAB BARS,ONE SIDE AND ONE BACK OF TOILET, 33"ABOVE AND PARALLEL 1. WHERE TOWEL,SANITARY NAPKIN AND WASTE RECEPTACLES AND SIMILAR M ACCESSIBLE PAINT STRIPING '0-%MA), REQUIRED ON SHADED TO THE FLOOR, EXCEPT WITH A TANK-TYPE TOILET WHICH OBSTRUCTS PLACEMENT,THE - Q �N �� OTION OF THE RAMP. DISPENSERS AND DISPOSAL FIXTURES ARE PROVIDED, AT LEAST ONE OF < > AT ACCESS AISLES: GROOVED BORDER � PRGRAB BAR MAY BE AS HIGH AS 36". DIAMETER OF GRAB BAR IS 1 1/4"TO 1 1/2",OR EACH TYPE IS TO BE LOCATED WITH ALL OPERABLE PARTS, INCLUDING CAIN � � � USE COMMERCIAL GRADE COATING SPECIFICALLY INTENDED FOR STRIPING ON PAVED MUST BE ON THE LEVEL SEE 20/AO.2 SHAPE PROVIDES AN EQUIVALENT GRIPPING SURFACE. r-- 9 TRAFFIC SURFACES. SLOTS,WITHIN 40"FROM THE FLOOR. MINIMUM 30"x48"CLEAR FLOOR ,® � _ � M/ti �n� PROVIDE 4"BORDER IN BLUE COLOR CONTRASTING WITH THE PAVED SURFACE. SURFACE AT THE TOP 2. IF GRAB BARS ARE MOUNTED ADJACENT TO WALL THE SPACE BETWEEN WALL AND BAR SPACE TO ALLOW FORWARD OR PARALLEL APPROACH TO ACCESSORIES. �.� ACCESSIBLE PROVIDE 4"CROSS-HATCHINGS BETWEEN BORDERS AT 36"O.C.AT 450 IN BLUE COLOR OF THE RAMP IS TO BE 1 1/2". a0 O ROUTE CONTRASTING WITH THE PAVED SURFACE. 2• MOUNT MIRRORS WITH BOTTOM EDGE NO MORE THAN 40"FROM FLOOR. 4U 0 = CURB RAMP,SEE 11/AO.2 3. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS. 3. LOCATE TOILET TISSUE DISPENSER ON WALL WITHIN 12"OF FRONT EDGE OF � S * *5 5'-0" ` > PROVIDE 4"STRIPING 4. GRAB BARS AND ANY SURFACE ADJACENT TO THEM CANNOT HAVE ANY SHARP OR TOILET SEAT. O Q) 0 8'-0STANDARVAN D PROVIDE 12"LETTERS,"NO ABRASIVE ELEMENTS. EDGES ARE TO HAVE A MINIMUM RADIUS OF 1/8". Q (L PARKING"@ALL LANDINGS,TYP. 5• GRAB BAR CAPACITY SHALL BE A MINIMUM 250 POUNDS. � TYPICAL PARKING STALL DESIGN N.T.S. 15 TYPICAL CURB RAMP N.T.S. 11 TOILET ACCESSORIES 3/8"=V-0" 3 0 ENTIRE WIDTH OF RAMP OR 12 1' 6" 24 WALKING SURFACE RAMP A MIN. MAX. 5'-0"MIN. 5' 0"MIN. 16"-1 , L 16"-18" 1 IN MIN. „ ADA SIGN 36"GRAB BAR '` 36"GRAB BAR '"- ID 6 MIN. HI-LOW FACE OF I IF ALCOVE WALL o e N `[ `� 32"MIN. 2.4"MAX. a °° ° ,..� 32"MIN. �; T ° $ 31'/ DRINKING STANDARD • < Z z _ ¢ 2"MIN. 2"MIN. 4 ° FOUNTAIN zUJ °0 0 o O o o U o HEIGHT _ STANDARD co � _A MIN. ` � � _ _ C7 ® Q a� O o HEIGHT ` ¢ 2"MIN cv <v LU Caw nter� ACCESSIBLE a ACCESSIBLE g CLEAR R ( EAR CLIA `t 4 z Oo Q°(� O 3 o CaC_ )Q tJ oo �� GRADE 2 C �} d ¢ Q Q Q Q Q HEIGHT X HEIGHT 0 SPACE O O O Grooved Border BRAILLE - z ¢ o - z � ¢ ~ - - b0" 60"MIN.00v 0 �/ �- - 6' MAX. 'n i� 'v? CLR. ADA ROOM A-A Z 2"MIN s ' IDENTIFICATION M v - � cit _ CLIA U z o �a I _ LEVEL AND 4"M! 32"MIN. 0 cv @ @ @ @ @ SIGN ") i. 0"x60" I z N U r © O Q Q Q a -� 0 L wonnert CLEAR FLOOR N (� Project Number l/ z INTERIOR COMPARTMENT: PPM 16049. 1 p ° STRIKE SIDE 18"MIN. SPACE4 10 9 * I CLEAR o Q Q A A a 4 4 a 4 OF DOOR 19"MAX. PLAN SECTION A-A 9z v ° a � - -- � � t,.} 0 1• FLUSH VALVE IS ON WIDE SIDE OF TOILET AREA. z A ° o AREA FOR 0 a FLUSH ACTIVATOR :o U \O 2• 44"MAXIMUM FROM FLOOR TO FLUSH VALVE. '�-�' '�-' Q 0 @ D��a�I A co HARDWARE DRINKING FOUNTAIN NOTES: 16"-18" ON WIDE SIDE � 3• 5 LBS. MAXIMUM FORCE TO OPERATE VALVE. Sheet Name i 4• SEE 3/AO.2 FOR HEIGHTS OF GRAB BARS AND _ 1. DRINKING FOUNTAINS ARE TO BE LOCATED WITHIN ALCOVES OR POSITIONED SO AS NOT TO MULTIPLE ACCOMMODATION ROOMS-NEW CONSTRUCTION 50%MIN z BE IN CORRIDOR OR WALK. ACCESSORIES. AT TOP uNisex FRONT APPROACH SIDE APPROACH 6"MIN., 8"MAX. 60%MAX. IN TAPERED 2GES . WHEN ENFORCING AGENCY ALLOWS AN UNREASONABLE HARDSHIP, FOUNTAINS MAY BE TOILET ROOM NOTES: FROM F.O.CURB0.9"MIN. AT BASE O WHERE NOTES LOCATED IN PATH OF TRAVEL BUT MUST HAVE A TEXTURED AREA FOR 1 FOOT AROUND 1• CLEAR ACCESS A MIN.OF 44"IN WIDTH THROUGHOUT SANITARY FACILITY TO REACH ACCESSIBILITY 4„ EXPOSED 1. CHARACTERS AND SYMBOLS SHALL CONTRAST WITH THEIR BACKGROUND. FOUNTAIN, OR WING WALL WILL BE REQUIRED ON EACH SIDE OF FOUNTAIN. THE HANDICAPPED COMPARTMENT. (48"CLEAR @ HINGE SIDE APPROACH TO 2. CLEAR OPENING WIDTH OF 32"IF LOCATED AT THE END.34"IF LOCATED AT SIDE OF Section A-A 2. IDENTIFICATION SYMBOLS ARE TO BE CENTERED ON DOOR 60"ABOVE FLOOR AND 3. THE BUBBLER CAN BE ACTIVATED BY HAND OPERATED LEVER WITHIN 6"OF THE FRONT, PUSH 2 COMPARTMENT). E A CLEAR SPACE OF SUFFICIENT SIZE TO INSCRIBE A 60'DIA.CIRCLE COMPARTMENT. DETAILS ARE TO BE DISTINCTLY DIFFERENT FROM THE DOOR IN COLOR AND CONTRAST. BAR ALONG FRONT OR BY ANOTHER APPROVED CONTROL EASILY OPERATED BY A PERSON 3. COMPARTMENT DOOR PROVIDES MINIMUM 9"CLEARANCE FOR FOOTRESTS DETECTABLE WARNINGS: UNDERNEATH DOOR. 1, IF A WALK CROSSES OR ADJOINS A VEHICULAR WAY, AND THE WALKING SURFACES ARE NOT 3. PROVIDE ROOM IDENTIFICATION SIGN ON LATCH SIDE OF DOOR. WITH DISABILITIES.THE TEXTURED SURFACE IS TO BE CLEARLY IDENTIFIABLE BY A BLIND PERSON WITHIN THE SANITARY FACILITY ROOM ATA HEIGHT A 27"A.F.F. DOORS OTHER THAN USING A DANE. THE TOILET COMPARTMENT DOOR MAY NOT ENCROACH MORE THAN 12"INTO CIRCLE. 4. INSIDE AND OUTSIDE OF THE COMPARTMENT DOOR IS EQUIPPED WITH A LOOP OR SEPARATED BY CURBS,RAILINGS, OR OTHER ELEMENTS BETWEEN THE PEDESTRIAN AREAS AND 4. LETTERS&NUMBERS ON SIGNS SHALL BE RAISED 1/32"MIN.,SHALL BE A MIN.OF U-SHAPED HANDLE IMMEDIATELY BELOW THE LATCH.THE LATCH IS A FLIP-OVER THE VEHICULAR AREAS,THE BOUNDARY BETWEEN THE AREAS SHALL BE DEFINED BY A 5/8"HIGH, A MAX. OF 2"HIGH, &SHALL BE SANS-SERIF UPPERCASE CHARACTERS 4. WATER STREAM IS TO BE PARALLEL TO THE FRONT SIDE OF FOUNTAIN. 3. WHERE 6 OR MORE STALLS ARE PROVIDED; 1 SHALL BE SIDE TRANSFER STALL AS SHOWN, STYLE,SLIDING,OR OTHER HARDWARE NOT REQUIRING TIGHT GRASPING OR CONTINUOUS DETECTABLE WARNING WHICH IS 36"WIDE. ACCOMPANIED BY CONTRACTED GRADE 2 BRAILLE. 5. IN EXISTING BUILDING AND FACILITIES WHERE UNREASONABLE HARDSHIP IS GRANTED,THE AND 1 SHALL BE A 36"WIDE SEMI-AMBULATORY STALL. TWISTING. 2. CURB RAMPS SHALL HAVE A DETECTABLE WARNING THAT EXTENDS THE FULL WIDTH AND DEPTH EXISTING FOUNTAINS MAY REMAIN. HOWEVER,THE TEXTURED SURFACE OR WING WALLS HANDICAPPED COMPARTMENT DOOR: 5. OPENING HARDWARE IS CENTERED BETWEEN 30"AND 44"ABOVE FINISH FLOOR, Sheet Number OF THE CURB RAMP, EXCLUDING THE FLARED SIDES. WILL BE REQUIRED. 6. DOOR MAY SWING IN OR OUT.COMPLY WITH CLEAR SPACE REQUIREMENT 3. DETECTABLE WARNINGS SHALL CONTRAST VISUALLY WITH ADJOINING SURFACES, EITHER 6. A STANDARD HEIGHT DRINKING FOUNTAIN MUST BE PROVIDED WITH AN ACCESSIBLE ONE. 1. EQUIPPED WITH AN AUTOMATIC CLOSING DEVICE (3 SECOND MINIMUM SWEEP TIME FOR ALL DOORS. LIGHT-ON-DARK OR DARK-ON-LIGHT. FROM OPEN POSITION OF 70 DEGREES TO A POINT 3"FROM THE LATCH). AO *2 WARNING DOMES N.T.S. 20 RESTROOM SIGNAGE N.T.S• 16 DRINKING FOUNTAIN 3/8"=1'-0" 1TOILET ROOMS 3/16"=1'-0" 6 GA.CLIP L WITH 34 10 SMS DIMENSION PLAN LEGEND a THIS s MBO BY SYMBOL LEG 1. INSTALL SELF-ADHESIVE STRIP SIGN ACROSS THE FRAME 8. PROVIDE 5/8"PLYWOOD BACKING FROM FINISH FLOOR AT THE TOP OF THE DOOR STATING'THIS DOOR MUST TO 6-0"A.F.F. @ WALL BEHIND MOP SINK. REMAIN UNLOCKED WHILE BUILDING IS OCCUPIED". Ken McCracken, 362S125-33 (3 5/8") STUD BRACE @ 9. 24"X24"X5/8"PLYWOOD BACKING BEHIND PHONE SHELF Architect 48"O.C. MAX.-CENTER OVER 2. EXIST.THRESHOLD TO REMAIN VERIFY 1/2"LIP MAX. & @ 48"A.F.F.TO CENTER OF BACKING-SEE DETAIL STUD BELOW BEVELED SIDES THAT SLOPE 1 :2 MAX.-REPLACE AS 15/A4.0. Architecture•Program Management•Permitting NEEDED. 10. 1"F.R.P. OUTSIDE CORNER;TYPICAL AT ALL OUTSIDE 16219 SE 12th STREET 3. DASHED LINES INDICATES HEADER/SOFFIT ABOVE-SEE CORNERS WITH F.R.P. SUITE 202 A2.0 &A3.0. VANCOUVER,WA 98683 11. OMIT F.R.P FROM WALLS BEHIND COOLER. 4. EXISTING ELECTRICAL PANEL TO BE REPLACED-VERIFY �„ Contact: Martin D. Lakey LOCATION-REFER TO ELECTRICAL DRAWINGS. ENSURE 12. PROVIDE 5/8"PLYWOOD WALL BACKING AT MANAGER'S / 3'-4 -p 362T125-33 TRACK WITH (2) #8 (360)719-1952 SCREWS @ EACH STUD-TYP. A 30"x36"CLEAR SPACE IN FRONT OF PANEL. DESK FROM 54"A.F.F.TO 102"A.F.F. ken.mccracken@comcast.net 5. PROVIDE 5/8"x 24"W. PLYWOOD BACKING FROM 24" ~ UNISEX A.F.F.TO 60"A.F.F. BEHIND HAND SINKS-PROVIDE FIRE 102 �� RESTROOM RATED PLYWOOD IN DEMISING WALL AS REQUIRED. Ln 106 6. PROVIDE 5/8" PLYWOOD BACKING FROM 36"A.F.F.TO ;. �• iv WALL STUD PER PLAN 84"A.F.F.- PROVIDE FIRE RATED PLYWOOD IN DEMISING WALL AS REQUIRED. ~ 1 4 40 7. G.C.TO PROVIDE AND INSTALL 36"X36"X3/4"SURFACE ,� :RT o 1068 � � ,�E.D A CMOUNTED PLYWOOD BACKER BOARD TIGHT TO CEILING NOT A �f 1.AND PAINT P4. FOR LOW VOLTAGE COMPONENTS. SEE I I - ' °' � KENNETH J. DATA BOARD DETAIL ON E1.0 FOR ADDITIONAL 1M RACKE1 INFORMATION. B AM S, WA WALL & HEADER BRACING 3"=1 13 , , �� license#5599 WALL TYPES I I B MANAGER OF O� MAX. CLEAR HEIGHT (1) o 1 1 103 ��/ 1�� TYPE 16"O.C. 24"O.C. EXISTING WALL TO REMAIN (WALL , 01/1(9/17 362S]25-18 (3-5/8"x 1-1/4"x 18 MILS) 13'-8" 11'-2" O I I i CONSTRUCTION VARIES) r 3625125-33 (3-5/8"x 1-1/4"x 33 MILS) 17'-0" 15-0" I I - KJMl1434 362S125-43 (3-5/8"x 1-1/4"x 43 MILS) 18'-6" 16-0" __J1 - 362S125-54 (3-5/8"x 1-1/4"x 54 MILS) 20'-0" 17'-6" > Ln Seal 600S125-33 (6"x 1-1/4"x 33 MILS) 25-6" 22'-6" 7 600S125-43 (6"x 1-1/4"x 43 MILS) 27'-6" 24'-0" INTERIOR METAL STUDS PER ICBO #4943 2A 5/8"GYPSUM BOARD SHEATHING 12 (1) WHERE LATERAL BRACE SUPPORT IS - 362S125-33 (3 5/8") METAL STUD FRAMING @ 16"O.C. PROVIDED, CLEAR HEIGHT IS THE DISTANCE BETWEN LATERAL SUPPORTS O 5/8"GYPSUM BOARD SHEATHING - ---- - - AND FLOOR OR ROOF CONNECTIONS Z *TAPE, MUD, AND SAND ALL JOINTS PREP AREA *CONSTRUCT WALL FLUSH TO UNDERSIDE OF "00 1 W 5/8"GYP. BD, EACH SIDE OF CEILING GRID a 6 _5 d METAL STUDS-SEE PLANS ct �rCL TRACK GUAGE TO MATCH FOR MOISTURE RESISTANT 2B � N 5/8' GYPSUM BOARD SHEATHING _ VERTICAL STUDS U.N.O.WITH GYP. BD. LOCATIONS ¢ 362S,25-33 (3 5/8") METAL STUD FRAMING @ 16"O.C. 0 N " MIN. (2) #8 SCREWS EACH g 3 1/2"BATT INSULATION c 11 d STUD l45"x 3/4"MIN. HILTI � z0 5/8"GYPSUM BOARD SHEATHING a UJ FASTENERS PER ICBO #2388 AT __A___ *TAPE, MUD, AND SAND ALL JOINTS � 1 w 16"O.C. MAX. * LU CONSTRUCT WALL FLUSH TO UNDERSIDE OF z EXISTING CONCRETE HOLD GYP. BD. 1/4"MAX. A.F.F. CEILING GRID W 6 W O < FLOOR U 0 d a W rx cc G < I- =) V) 6) N F^ U Q I U F O ON o _W W O- d. W WV n r3,-0„ COOLER W 1-7 4 5!8"GYPSUM BOARD SHEATHING (PAPA MURPHYS z 1 O4 , z U z co WALL TO FLOOR CONNECT. 1-1/2"-,'-0" 14 SIDE ONLY) Ln w o 1a X z0 co 0 6005125-33 (6")METAL STUD FRAMING @ 16"O.C. v a 9'-0" n W 0 00 __J '� Oz 5/8"GYPSUM BOARD SHEATHING z r � ¢ `~ EXISTING STRUCTURE * a j' 5 9 Q TAPE, MUD, AND SAND ALL JOINTS - Z b o i-z: (2) #10 WOOD SCREWS *CONSTRUCT WALL TO UNDERSIDE OF ROOF DECK @ 32"O.C.OR AT EACH ¢ ROOF MEMBER. T LJI _6„ t0 W - ALL WALLS, NEW OR EXISTING, RECEIVING A PAINTED FINISH OR MURAL COVERING (TYP. FRONT-OF-HOUSE) ARE r) z I .1 UJ TO BE (MADE) SMOOTH AND UNTEXTURED. I 5 -PROVIDE MOISTURE RESISTANT GYPSUM BOARD BEHIND AND ADJACENT TO ALL SINKS. z L-- ---- -------�- -PROVIDE DIAGONAL BRACING @ TOPS OF FREESTANDING WALLS AND HEADERS PER 13/A1.0. 4'-0" 4'-0" 13'-11 3/4" p" 6'-3 1/2" -CONSTRUCT FULL HEIGHT (FROM FINISH FLOOR TO ROOF DECK) WALLS PER 14/A,.0. UJ -INSTALL GYP. BD.CONTROL JOINTS AS NEEDED TO PREVENT CRACKING. -PLYWOOD BACKING,WHERE INDICATED, IS TO BE INSTALLED BETWEEN STUDS. 3 10 FRONT LINE LL DOOR SCHEDULE W 101 W DOOR FRAME DOOR HDWR. 2"DEEP X 18 GA.TRACK # SIZE GROUP '{- MAT'L. FINISH MAT'L. FINISH CD Co 100 EXIST.3-0"x 7'-0" EXIST. EXIST. EXIST. EXIST. A (3) ON 102 NEW 3'-0"x 7'-0" STEEL PAINT P4 HC.AL. PAINT P4 D (3) III 0 Cy) �r*_, 103 NEW 3'-0"x 7'-0" NEW PAINT P4 NEW PAINT P4 D (3} N � _6,WALL STUD PER PLAN 106B NEW 3'-0"x b'-8" STEEL (2) PAINT P4 SC.WD. PAINT P4 B `i `a O.0 w 4- 0 U I C� W 0 Z3 LOBBY CL 10Q ( 0 NOTES: 1.ALL NEW INTERIOR DOORS TO BE PAINT GRADE. E- FULL HEIGHT WALL BRACING 3-1 -0 2. FRAME: 16 GA. LO 3.CONFIRM HARDWARE ON ALL EXISTING DOORS TO REMAIN. REPLACE IF REQUIRED. _ O I\ DOOR HARDWARE SCHEDULE GROUP A (REUSE EXISTING HARDWARE WHEN GROUP C (REUSE EXISTING HARDWARE WHEN 1 2 POSSIBLE) POSSIBLE) 1. THERMALLY-BROKEN ALUMINUM 1. THERMALLY-BROKEN ALUMINUM THRESHOLD, 1/2"MAX. THRESHOLD, 1/2"MAX. - -- C F.0_13. HEIGHT, 1:2 BEVELED EDGES HEIGHT, 1:2 BEVELED EDGES 2. RODENT-PROOF DOOR SWEEP 2. RODENT-PROOF DOOR SWEEP 100 f/ 4 3. WEATHERSTRIPPING (JAMBS AND HEAD) 3. WEATHERSTRIPPING (JAMBS AND HEAD) 4. (3) NRP HEAVY-DUTY BUTT HINGES 4. (3) NRP HEAVY-DUTY BUTT HINGES 5. HEAVY-DUTY CLOSER 5. HEAVY-DUTY CLOSER Project Number 6. CYLINDER 6. PANIC HARDWARE PPM 1604 7 . 7. PULL 7. CYLINDER 7 GROUP B (REUSE EXISTING HARDWARE WHEN 8. DOOR VIEWER POSSIBLE) 4• ALUMINUM KICKPLATE Sheet Name 1. PRIVACY SET GROUP D (REUSE EXISTING HARDWARE WHEN 2. BUTT HINGES POSSIBLE) 29'-41/2" DIMENSION G.C. TO VERIFY THIS DIMENSION IN THE FIELD; CONTACT PMI 3. CLOSER 1• LOCK SET CONSTRUCTION PROJECT MANAGER IF THERE ARE ANY DISCREPANCIES 4. RESTROOM SIGNAGE 2. BUTT HINGES 5. (3) SILENCERS 3. (3) SILENCERS FLOOR 6. ALUMINUM KICKPLATE(PUSH SIDE) GROUP E PLAN & INCLUDED HARDWARE KIT BY DOOR MFR. SCHEDULES NORTHSheet Number A 1 ,00 DIMENSION FLOOR PLAN 1/4"=1'-0" 4 REFLECTED CEILING PLAN LEGEND 1. BOTTOM OF HEADER @ 7'-0"-REF.A3.0. 2. BOTTOM OF SOFFIT @ 6'-6"-REF.A3.0. Ken McCracken, 3. PROVIDE CONTINUOUS DRAFT STOP PER LOCAL CODE AND IF ANY Architect ATTIC/CONCEALED ROOF SPACE IS OVER 3,000 S.F. Architecture•Program Management•Permitting 4. DASHED LINE INDICATES EXTENT OF COOLER BELOW-ENCLOSE OPEN SIDES ABOVE COOLER WITH VERTICAL CEILING GRID AND TYPE C1/C1.1 WASHABLE CEILING 16219 SE 12th STREET PANELS. SUITE 202 VANCOUVER, WA 98683 5. DASHED LINES INDICATES EXTENTS OF COUNTER ASSEMBLY BELOW. 6. EXTERIOR SIGNAGE BY OTHERS UNDER SEPARATE CONTRACT-SIGN Contact:Martin D. Lakey MANUFACTURER TO PROVIDE SHOP DRAWINGS FOR APPROVAL. (360)719-1952 ken.mccracken@comcast.net 7. HVAC DISTRIBUTION NOT SHOWN ON THIS PLAN. REFER TO SHEET M1.0 FOR MECHANICAL SYSTEM LAYOUT 8. CEILING GRID CONTINUES OVER RESTROOM. \� UNISEX a RESTROOM 9. G.C. IS RESPONSIBLE TO VERIFY NO CONFLICT BETWEEN LIGHT AND CEILING 106 CLG:C4 FIXTURES AND FIRE SPRINKLERS, IF EXISTING.SPRINKLER HEADS ARE TO BE ADJUSTED @ 8'-0"A.F.F. TO ACCOMMODATE CEILING PLAN PER INSTRUCTIONS ON INDEX SHEET. " 10. ADJUST ACCENT LIGHTS MAX.4"IF NEEDED TO AVOID CEILING GRID. `\ / C - �ZD ARS 11. SEE FINISH SCHEDULE ON SHEET A2.1 FOR CEILING TYPES. \ /' C ✓. NOT A PART - KENNETH J. M RACKE � EQUIPMENT DESIGNATED BY THIS WA A # KEY NOTE DESIGNATED BY THIS SYMBOL # License O SYMBOL,SEE SHEET EQ1.1 ��� c c OF MANAGER 01118117 LM 103 C CLG:C1.1, C3 KJM/1434 @ 9'-9.5"A.F.F. Seal C C C PREPAREA c 17- -- — — --� 75A. CLC3 @ F.F. — — C 3 7 9 11 z 1 ° Q < 03 C c m w LU � LU ILU Z C w In a COOLER `` J w U = 104 COa 10' 20' LU 0 00 I.- N O ap N N ~ 2'-0" — I Q Q L2 - I B li i 5 , 2 , 1000 DA Ah A6 i FRONT LINE B B B 101 "' — — — - - — — N 3.1 '-0 1/ --- @ 91-9."" A.F.F. V) co — ST RT CREA NG N H � � ( � � al 3 7 9 11 � 0.0ry 10 IJP 8 c.) N -41 1 LOBBY -i � 100 - - t37 a- CLTC�, C 3 1TY @ A.F. . Q t c, i A A L 1 0 10 — _ O 2'— --- i f cv 0 EN 8'-4 1/2" A4 0 O E 6 Project Number PPM 16049.1 Sheet Name REFLECTED CEILING PLAN NORTHSheet Number A2 *0 REFLECTED CEILING PLAN FLOOR FINISHES PLAN LEGEND 1. HEAVY DASHED LINE INDICATES EXTENT OF WALK-IN COOLER 2. HEAVY DASHED LINE INDICATES EXTENT OF COUNTER ASSEMBLY Ken McCracken, 3. INSTALL LVT TILE IN 1/3 RUNNING BOND PATTERN AS SHOWN Architect 4. INSTALL VCT TILE IN STACKED BOND PATTERN Architecture•Program Management•Permitting 5. LINE INDICATES TRANSITION OF TILE TYPES-SEE DETAIL 3/A4.0. 16219 SE 12th STREET SUITE 202 6. INSTALL SCHLUTER RENO-T STRIP BETWEEN TWO TILE TYPES, PART#T925AE, RE:4/A4.0 VANCOUVER, WA 98683 7. INSTALL WATERPROOF MEMBRANE BEHIND FRP TO 12"A.F.F.;APPLY CLEAR SILICONE Contact: Martin D. Lakey SEALANT TO TOP OF BASE. (360)719-1952 ken.mccracken@comcast.net UNISEX RESTROOM 106I FLOOR: F2 BASE: B2 \ / / BRED ARC NOT A PART KENNETH J. r / \ \ M RACKE AM S. WA # �KEY NOTE DESIGNATED BY THIS SYMBOL \/ n License�5599 g tJ i OF ROOM FINISH SCHEDU E MANAGER ,I 103 01118/17 ROOM # AREA FLOOR BASE WALL CEI'_ING CEILING REMARKS r FLOOR: F2 HEIGHT �' BASE: B2 K1M/1434 100 LOBBY F1 B1 W1,P1 C1,C3.1 9'-9.5" REF. ELEVATIONS FOR APPLICATION OF WALL FINISHES Seal 101 FRONT LINE F1 81 W1,P1 C1,C3.1 9'-9.5" REF. ELEVATIONS FOR APPLICATION OF WALL FINISHES 102 PREP AREA F2 B2 W4 C1.1,C3 9'-9.5" 103 MANAGER F2 B2 P4 C1.1,C3 9'-9.5" 104 COOLER F2 B3, B4 W7 W7 8'-4" MAX. SEE MFR. SPEC, SHEET FOR ADDITIONAL INFORMATION PREP AREA 106 UNISEX RESTROOM F2 B2 W3,P2 C4 8'-0" FLOOR: F2 BASE: B2 I v FINISHES SCHEDULE TYP. KEY # MANUFACTURER DESCRIPTION REMARKS SIZE SUPPL I BY I FLOORING t Z � 1 < Q � . O L m I NATURAL CREATIONS EARTH CUTS LUX. USE ARMSTRONG S-288 PREMIUM o° N F1 ARMSTRONG 12"x24"x1/8" GC w =)VINYL TILE BRACO MORTAR NA331 OR S-543 HIGH MOISTURE ADHESIVE I , 'sem V W LU LU IMPERIAL TEXTURE VCT — STC EXCELQN GC > w °- F2 ARMSTRONG USE ARMSTRONG APPROVED ADHESIVE 12"x12"x1/8" w O IMPERIAL — FIELD GRAY I = Z 7 r- COOLER W J 104 14 U UJ 10' x 20' BASE INTBOASEFB3 � o 00 t \, 6 EXT. BASE: B4 t p 131 BURKE RUBBER COVE BASE TYPE TP RUBBERMYTE BLACK 701 1/8" GC I N o A4.0 _ 1 Q B2 BURKE FLOORING RUBBER COVE BASE, TYPE TP 4" GC RUBBERMYTE 1/8" BLACK 701 B3 IMPERIAL SMOOTH ALUMINUM COVE BASE FOR 1/2" COVE, NSF—COMPLIANT, .080" 6" FSE ----- COOLER BOX INTERIOR B4 IMPERIAL STUCCO GALVANIZED METAL COVE 1/2" COVE, NSF—COMPLIANT, 28—GA 6" FSE BASE FOR COOLER BOX EXTERIOR UE t GROUT 2 5 G1 MAPEI ULTRACOLOR PLUS SANDED GROUT GC TO SEAL_ GROUT GC GRAY 09 G2 MAPE1 ULTRACOLOR PLUS SANDED GROUT GC TO SEAL GROUT GC FRONT LINE BISCUIT 14 WALL APPLICATIONS 101 .._ ..... FLOOR: Fl N W1 DALTILE SKYBRIDGE GLAZED CERAMIC TILE GROUT G2, 1/16 JOINT 12"x24"x3/8" GC BASE: Bl OFF WHITE SY95 } W2 DECOR SUPPLIER WASHABLE VINYL WALL COVERING INSTALL SEAMS AND GRAIN HORIZONTAL OWN WOODGRAIN PATTERN RIGID VINYL SHEET, VELVET TEXTURE MAY BE SUBSTITUTED FOR PAINT _ V) W3 InPro CORPORATION (I.P.C.} 405 FEATHER 0238 P1 IN NON—LOBBY AREAS 040" GC t `M W4 MARLITE PEBBLE—SURFACE FRP APPLY FULL—HEIGHT GC t I 0 WHITE P-100 M W5 InPro CORPORATION (I.P.C.) 500 WALL GUARD REFER TO ELEVATIONS FSE FEATHER 0238 W7 IMPERIAL COOLER BOX WALL AND CEILING PANELS, 26—GA STUCCO GALVANIZED STEEL GC ' 3 - INTERIOR AND EXTERIOR I = Q 00 ry PAINT 4+= P1 BENJAMIN MOORE SEMI—GLOSS FINISH PAINT APPLY P5 FIRST GC I I .0 OC-45 SWISS COFFEE" P2 BENJAMIN MOORE SEMI—GLOSS FINISH PAINT APPLY P5 FIRST GC \ 1 ® AF-705 "CINDER" L-- SEMI—GLASS FINISH PAINT � LOBBY � 0 P4 BENJAMIN MOORS APPLY P5 FIRST GC -+— 2122-70 "SNOW WHITE" 100 V) FRESH START MULTI—PURPOSE FLOOR: F1 P5 BENJAMIN MOORS ACRYLIC LATEX PRIMER 023 APPLY UNDER P1/P2/P4 GC I BASE: B1 I-- P6 BENJAMIN MOORS SUPER SPEC HP URETHANE ALKYD GC l() GLOSS ENAMEL P22-78 "ALUMINUM" 0 CEILING 1 C1 ARMSTRONG GEORGIAN UNPERFORATED LAY-INSHIBILITY PANEL SPECIAL ORDER, 3-WEEK LEAD TIME 2'x2' GC I TYP. Bl C1.1 ARMSTRONG GEORGIAN 793 HIGH—WASHIBILITY SPECIAL ORDER; 3—WEEK LEAD TIME 2'x4' GC -- UNPERFORATED LAY—IN CEILING PANEL C3.1 SUSPENDED CEILING GRID MODIFY EXISTING: ADD CROSS—TEES TO REFER TO REFLECTED CLG. PLAN GC CREATE 2x2 GRID j C4 GYPSUM BOARD CEILING, NEW PAINT P1 IF PUBLIC RESTROOM REFER TO REFLECTED CLG. PLAN GC PAINT P4 IF EMPLOYEE RESTROOM !� Project Number PPM 16049. 1 ARMSTRONG: FLOORING: 800.442.4212 OR armstrong—orders@armstrong.com FIRE CLASS/FLAME SPREAD Sheet Name NATIONAL ACCOUNT #4100013 CEILING: 800.442.4212 OR armstrongcsa@armstrong.com CEILING TILE FINISH NATIONAL ACCOUNT #PAPA MURPHY'S (GRID SYSTEM AVAIL. @ NAT. ACCT. PRICING) FLAME SPREAD: 25 BENJAMIN MOORE: 866.708.9181 (PROMPT FOR CUSTOMER CARE) OR benjaminmoore.com SMOKE DEVELOPED: 50 NATIONAL ACCOUNT #NA-015. CLASS 'A' INTERIOR FINISH PLAN BURKE FLOORING: 800.447.8442 OR burkeflooring.com/contact—us.php DALTILE: 877.556.5728 OR products.daltile.com/locate.cfm FRP r"'1 NATIONAL ACCOUNT #NA-001259. FLAME SPREAD: 200 AND InPro CORP: BRUCE KLIND — 800.214.7749 x5118. NATIONAL ACCOUNT #452517 SMOKE DEVELOPED: >400 KOSTER: DAVID ZEAGLER — 281.723.7057 OR david@kosteruso.com CLASS 'C' INTERIOR FINISH SCHEDULES MAPEI: 800.426.2734 OR mopei.com/US—EN/contact—us.asp MARLITE: 800.377.1221 OR mariite.com/contact.aspx IPC RIGID VINYL SHEET REFERENCE PAPA MURPHY'S CHAIN ACCOUNT WHEN ORDERING FRP FLAME SPREAD: 25 NORTH Sheet Number MATTHEWS PAINT: 800.323.6593 OR matthewspaint.com SMOKE DEVELOPED: 350 CLASS 'A' INTERIOR FINISH A2 . 1 FINISH PLAN 1/4"=V-0" 4 KEYNOTES EQ EQ OITEM SHOWN IS IN FOREGROUND, NOT ATTACHED TO WALL. /� START INSTALLATION OF VINYL WALL COVERING PANELS AT CEILING GRID AND CUT-TO-FIT FROM Ken McCracken, Q Q < 2 BOTTOM OF PANEL IF NEEDED;GRAIN TO RUN HORIZONTALLY;REFER TO VINYL WALL COVERING `�/ SEAMING DETAIL FOR MORE INFORMATION Architect FINISH EDGE OF VINYL WALL COVERING WITH I.P.C.VINYL WALL CAP TRIM #407, Architecture•Program Management•Permuting EQ EQ OPALOMINO 0270, PROVIDED BY DECOR SUPPLIER .� 16219 SE 12th STREET FINISH CORNER OF VINYL WALL COVERING WITH I.P.C.VINYL 90-DEGREE INSIDE CORNER SUITE 202 Plc� Up H 1 aTRIM#409, PALOMINO 0270, PROVIDED BY DECOR SUPPLIER VANCOUVER,WA 98683 D 2 P 1 ONOT USED. Contact:Martin D. Lakey (� ) I bken.mccracken@ omcast.net 6________ __/__ �6 MOUNT SIGN TO CEILING. LU 9D 0,_--1 C5vIrA4.0 6 4 R2 a _- R1 C;1 = o w2 wvi INT. ELEVATIONS NOTES � z � 2 R9 �ZD ARC o XX CINDICATES WALL APPLICATION OR FINISH -SEE ROOM FINISH SCHEDULE ON SHEET A2.1. KENNETH J. 0 0 4 6 M RACKE .t � INDICATES EQUIPMENT, FIXTURE OR DECOR ELEMENT-SEE SCHEDULES ON SHEET EQ1.1 A4.0LU \ _ I 70 FOR IDENTIFICATION OF ITEM AND RELATED INSTRUCTIONS. AM S, WA cn OPP, r f' License#5599 REFER TO SHEETS A1.0 AND A2.1 FOR ADDITIONAL INFORMATION V� ��j�\ 12 � OF 0� P1 01/18/17 K3Ml1434 4.-6,. 16-19' B 1 4'-0., B 1 Seal VINYL WALL TILE VINYL CREATE WALL ELEVATION - A EQUAL EQUAL M P1 \ z J P 1 C 101 EAT E F QES 1TU j i O Q G d ( "' w A ca c w F cn vt L ( � w w I > w °- UJ CL wa C14I A — W j v U S ca 10 I ° L UJ Q N o 0 p I I O 0 �. cti cv o // ff '5; 1 rf f B1 Bi IV 5 V)Co LOBBY WALL ELEVATION - B STOREFRONT ELEVATION - C 'N ry S-7" MENUS O Q� CL H 1 Q V) EQ EQ �� i p 1 O iSTART CRPATING W2 r— i r 4 j 2 IIF-R-El'"I Ou D , � G : ,11 EP1H LU LU ♦ ♦ R2 MAQE_D1���.Yi P 1 RI \ \ \ Q P 1 0 �X� O Project Number W PPM 16049. 1 -1 = 0 7 10 10 � LU o PI Pi , , J fl Sheet Name v / v, 5 5 f i i C i i i N ,�` INTERIOR i 2 , ,� , ,` 10.1 10.1,' ELEVATIONS B1 B1 B1 B1 Bl B4 B1 Sheet Number PARTITION WALL ELEVATION - D A3 .0 � W2 START INSTALLATION AT INSTALL WATERPROOFKen McCracken, MEMBRANE BEHIND FRP TO W GRAIN CEILING 12" A.F.F. AND APPLY Architect WIDTH OF OPENING TILE OR FLOORING PER a "' HORZ. CLEAR SILICONE SEALANT Architecture-Program Management•Permitting OR PER PLAN FLOOR FINISHES PLAN TO TOP OF BASE @ WALLS O o WASHABLE WOODGRAIN SURROUNDING/FACING 16219 SE 12th STREET TRANSITION STRIP PER 2 VINYL WALL COVERING 3—COMPARTMENT SINK SUITE 202 FLOOR FINISHES PLAN ------------ PANELS VANCOUVER,WA 98683 r //-- BASE TYPE B1 Contact:Martin D. Lake EY DASHED LINES INDICATE SEAMS BETWEEN PANELS {360}719-1952 W GRAIN _ ken.mccracken@comcast.net a " HORZ FLOORING TYPE F1 z 00 Q < Z w O " o ------------- CUT—TO—FIT FROM BOTTOM Co U TILE PER FLOOR GRAIN PANEL TO ACCOMMODATE uFINISHES PLAN HORz. BASE AND/OR LOW CEILING >N ° °° ° REFER TO FINISH BASE SCHEDULE ON SHEET A2.1 p�D pr A AND FLOOR FINISHES PLAN /rC.� 4——WIDTH VARIES — SEE ELEV. ON SHEET A2.1 '\,� KENNETH J. M RACKE �1 • AM S, WA TYP. TRANS. CLR. DOORS 1/2"=1'-0" 9 VINYL WALL COVERING SEAMING 3,8"=1'-0 5 LVT W/ RUBBER COVE BASE 3"=1'-0" 1 License#5599 LATERAL BRACING SHALL CONSIST OF FOUR 12 GA.WIRES SECURED TO MAIN OF RUNNER WITHIN 2"OF THE GRID INTERSECTION&SPACED 90"FROM EA.@ AN ANGLE 01118/17 NOT EXCEEDING 45"FROM THE PLANE OF THE CEILING TYP.@ 12'-0"O.C.&STARTING PROVIDE 24"Hx24"Wx5/8" KJM/1434 48"MAX.FROM WALLS-ANCHOR WIRES TO ROOF STRUCTURE. I PLYWOOD BACKING BEHIND VERTICAL BRACING SHALL CONSIST OFAI/2"DIA.E.M.T.COMPRESSION STRUTSHEETROCK GYPSUM BOARD INSTALL WATERPROOF Seal FASTENED TO CEILING GRID&ROOF STRUCTURE MEMBRANE BEHIND FRP T0. -ALL WIRES TIES ARE T1 BE THREE TIGHT TURNS AROUND ITSELF WITHIN 3 INCHES. ' GROUT G2, 1/16" 12" A.F.F. AND APPLY -LATERAL FORCE BRACING SHALL BE12FEET ONCENTER(MAX)AND BEGIN NO _ MOUNTING BRACKET (SHOWN WALL TILE W1 CLEAR SILICONE SEALANT TO TOP OF BASE @ WALLS �______________ --------------- FURTHER ___ __ FURTHER THAN$FEET FROM WALLS ; 1 ------_; FOR REFERENCE) PROVIDED VERTICAL STRUTS MUST BE POSITIVELY ATTACHED TO THE SUSPENSION SYSTEMS i AND INSTALLED BY OTHERS SURROUNDING/FACING AND THE STRUCTURE ABOVE. �' `' �' i ADJACENT WALL 3—COMPARTMENT SINK 4 -WALL MOLDINGS ARE REQUIRED TO HAVE A HORIZONTAL FLANGE 2"WIDE.ONE END OF THE CEILING GRID SHALL BE ATTACHED TO THE WALL MOLDING AND THE OTHER 25 GA METAL CLOSURE BASE TYPE B2 END SHALL HAVE A3I4"CLEARANCE FROM THE WALL AND FREE TOSLIDE. Q o I o CENTER OF BACKING PROVIDED BY EQUIPMENT ' , -LIGHT FIXTURES WEIGHING MORE THAN 10 POUNDS AND LESS THAN 56 POUNDS iv � ELEV-5'-4" SU P P LEI R _ . .-._ _.. VINYL WAIL COVERING W2 SHALL HAVE TWO 12 GAGE WIRES ATTACHED AT OPPOSING CORNERS OF THE LIGHT I Fol I FIXTURE TO THE STRUCTURE ABOVE. CENTER OF OUTLETS COOLER PANEL -PENDANT MOUNTED FIXTURES SHALL BE DIRECTLY SUPPORTED FROM THE I © ELEV•S-0" SCHLUTER QUADEC—K EDGE d FLOORING TYPE F2 FINISH ;#Q125AEK (1/2" STRUCTURE ABOVE USING A 9 GAGE WIRE WITHOUT USING THE CEILING SYSTEM SATIN AN N OD I Z ED ALUM.); FOR DIRECT SUPPORT. DUPLEX OUTLET BY E.C. U,L_ ANCHOR IN—PLACE WITH ° SINGLE RJ-45 JACK BY E.C. SCHLUTER KERDI—FIX a a 4 ° °d Z , ADHESIVE ° °°e °°° ° ° ° ¢ O I REFER TO: REFER TO FINISH °° ° ° REFER TO FINISH w II m FLOOR PLAN ON A1.0 SCHEDULE ON SHEET A2.1 SCHEDULE ON SHEET A2.1 03 V ELECTRICAL PLAN ON E1.0 AND INTERIOR ELEVATIONS AND FLOOR FINISHES PLAN ON SHEET A2.1 ON SHEET A2.1LU w > Ce CL LU CL w C7 Z WJ < J W J 12 GA.VERTICAL OPEN SIGN MOUNTING 14 COOLER-TO-WALL CLOSURE 10 WALL TILE TRANSITION b RUBBER COVE BASE3"= 2 " �' 48"O.C.-ATTACH TO 3/4"=1'-0" 3 1 0 1"=1'-0' 1'-0' F N O u0 TRAPEZEOBSTRUCTIONS (USE BACK TO BACK COLD ¢ N ,... ROLLED MTL.CHANNELS FOR O N v SPANS GREATER THAN 48" 12 GA.HORIZONTAL SEISMIC POS TERMINAL AND MOUNTING w RESTRAINTS SPLAYED 90" BRACKET PROVIDED AND R2 INT, F.O. COOLER PANEL < a FROM EA.OTHER BOTH INSTALLED BY OTHERS (SHOWN GYPSUM BOARD WAYS TO WITHIN 48"OF FOR REFERENCE ONLY) R m EXT. F.O. COOLER PANEL WALLS PROVIDE 24"x24"x$"PLYWOOD OPERATING CONTROLS PAINT (TYP.) OR OTHER BACKING BEHIND SHEETROCK ELEV.4'-0" FINISH AS SPECIFIED 112"D[A.E.M.T. ----- ---- INTERIOR BASE B3 COMPRESSION STRUT-DO ; ' TOP MOUNTING HOLE NOT EXCEED 1:6OUTOF l �j 4 ELEV.N-9"� J EXTERIOR BASE B4 FOR PLUMB ; - ; MIDPT.GLOVE HOLDER SCHLUTER QUADEC j EXPOSED COOLER WALL WALL SHELF-PROVIDED BY R g TRANSITION #Q60EB (1/4" ELEV.3'-8" EQUIPMENT SUPPLIER BRUSHED STAINLESSS) ` CROSS RUNNER G CENTER OF BACKING - CAULK COOLER PANEL TO 12 GA.SPLAYED WIRE ; L ELEV.4'-U' TOP OF SINK �o � 7 , FLOOR BEHIND BASE N ELEV.2'-10" { WALL FINISH W3 �� BRACING PERPENDICULAR � TOP OF SHELF 2° TO EA.RUNNER&8"MAX. ELEV.3'-8" -REFER TO ELEVATION k �— FROM EA.END OR BREAK " CENTER OF OUTLETS DRAWINGS FOR EXACT " p F ELEV.3'-4" PLACEMENT OF FIXTURES ° a L------------ - -- --------� (VARIES BY STORE ° 4 N MAIN RUNNER DUPLEX BY E.C. CONFIGURATION) ° °° ° a° C� °° ° FLOORING TYPES PER r-- i DUAL RJ-45 JACKS BY E.C. -REFER TO EQUIPMENT AND FINISHES PLAN w; '� ry = I DUAL RJ-14 JACKS BY E.C. (� REFER TO: FIXTURE SCHEDULES FOR REFER TO FINISH REFER TO FINISH `� `", � SPECIFICATIONS AND 4= FLOOR PLAN ON A1.0 LOCATIONS SCHEDULE ON SHEET A2.1 SCHEDULE ON SHEET A2.1 [LfLf #I- '— ELECTRICAL PLAN ON E1.0 AND FLOOR FINISHES PLAN 0 ON SHEET A2.1 _ O � C) -n CL �11 V) �: n CATEGORY "D" BRACING1"= 19 P.O.S. STATION MOUNTING 3/4"=1'-0" 1 11"=V-0" 3"=1'-0'5 TYPICAL HAND SINK ELEV. 1 1 PUBLIC RR WALL TRANS . (7] COVE BASE AT COOLER WALL (3]1'-0" 1"=1'-0" LO 0 PROVIDE C&J METAL G.C. TO PROVIDE TIE-OFFS TO PRODUCTS INC.VERTICAL REFER TO INSTALLATION STRUCTURE GLASS SNEEZE GUARD 4 N INSTRUCTIONS BY DECOR V-6" SUPPLIER DRYER VENT WITH INTEGRAL THREADED EYE BOLT ANCHOR _ RETURN AS REQUIRED BY TRANSITION STRIP PER BACKDRAFT DAMPER (OR 1/4-20 THREADED ROD LOCAL CODES FINISH PLAN A2.1 APPROVED EQUAL) 1/4-20 TOGGLE ANCHOR 1"o � o_ , ROOF DECK HOLE O GLASS SNEEZE GUARD 2x4 BLOCKING - SECURE TO u, < GROUT IF NEEDED -- T-BAR; G.C. MAY SUBSTITUTE w �- --' REFRIGERATED MAKELINE WITH UNISTRUT BAR ¢ C' O OR SERVICE COUNTER FLOORING TYPE T-BAR CEILING GRID m C'4 O Q AS SPECIFIED Project Number 1 4"0 EXHAUST PIPE PPM 16049. 1-LL C3 UJ > 3" DECORATIVE S.S. WASHER __j O w r tco 2"0 HOLE THRU Q Sheet Name CEILING PANEL " THICK PVC DIMENSIONAL w O Z STACKED WASHER & DRYER LETTERS MOUNTED TO TOP of > ~ © U-CHANNEL O 4 U - FLOORING TYPE Nr DECORATIVE METAL SLEEVE Q M ` AS SPECIFIED DETAILS 1j"x1 j" 20GA BRUSHED 'a EXISTING CONCRETE STAINLESS HANGING RAIL FLOOR SLAB FLOOR 1/4-20 LOCK NUT WITH WASHER REFER TO FINISH B.O. RAIL TYP. ALL FIXTURE AND HARDWARE SCHEDULE ON SHEET A2.1 ELEV. 8'- 4 COMPONENTS PROVIDED BY AND FLOOR FINISHES PLAN DECOR SUPPLIER, EXCEPT AS ON SHEET A2.1 1-1/2"=1'-0" 2"=1'-0" NOTED, AND INSTALLED BY G.C. Sheet Number DRYER VENT DETAIL 1/4"=1'-0" 2JO SUSP. DIMENSIONAL LETTERS VARIES 12 SNEEZE GUARD 1/2"=1'-0" 8 SAME-LEVEL FLOOR TRANS. 1"=1'-0" 4 A4 . 0 EQUIPMENT PLAN LEGEND 1. SEE INTERIOR ELEVATION DRAWINGS FOR LOCATION OF DECOR ELEMENTS 2. ENSURE 2" (TYPICAL) AIR GAP AROUND COOLER BOX Keri McCracken, 3. SNEEZE GUARD BY EQUIPMENT SUPPLIER-REFER TO 8/A4.0 Architect 4. APPLY CLEAR SILICONE SEALANT TO TOP OF BACKSPLASH/MOUNT(APPLY TO HAND Architecture•Program Management•Permitting SINKS, PREP SINK,3-COMP.SINK) 16219 SE 12th STREET 5. PROVIDE/INSTALL FIRE EXTINGUISHER-2A IOBC MOUNTED WITH TOP NOT MORE SUITE 202 THAN 5`-0"A.F.F.AND WITH CLEARANCE BETWEEN FLOOR AND BOTTOM OF VANCOUVER,WA 98683 EXTINGUISHER NOT LESS THAN 4", WITH 75'-0"MAX. DISTANCE BETWEEN EXTINGUISHERS-VERIFY FIRE EXTINGUISHER QUANTITY AND LOCATIONS WITH FIRE Contact:Martin D. Lakey MARSHALL PRIOR TO MOUNTING (360)719-1952 6. G.C.TO INSTALL KNIFE HOLDER, BROOM/MOP HOLDER AND UNIFORM RACK (ALL ken.mccracken@comcast.net PROVIDED BY OTHERS) -COORDINATE EXACT LOCATION WITH OWNER 7. REMOTE REFRIGERATION EQUIPMENT MOUNTED ON ROOF,SEE CONDENSING UNIT \� UNISEX MOUNTING DETAIL 14/--. 51 \� RESTROOM 106 N i� KENNETH J. NOT A PART M RACKE / U f� Jam` 29 53 52 EQUIPMENT DESIGNATED BY THIS / i7LL1 License#'55WssA < # �KEY NOTE DESIGNATED BY THIS SYMBOL SYMBOL,SEE SHEET EQ1.1 , 93�\ OF 28 MANAGER 1/18/17 TYPICAL CONDENSING UNIT MOUNTING DETAIL USING CONDENSING UNIT PROVIDED WITH COOLER; WEIGHT 103 PRECISION ALUMINUM PRODUCTS 'ALUMA STAND' ' TYP. DOES NOT EXCEED 250-LB i K'"viasa MODEL STD; ALL EXTRUSIONS ARE 6061-T6 ALUM. Sea! ALLOY/TEMPER; REFER TO acstands.com FOR TIE-DOWNS @ EA. CORNER: (3) ,#14 S.S. TEK ADDITIONAL SPECIFICATIONS OF COMPONENTS. SCREWS TO RAIL ANCHOR SCHEDULE ALUM. RAILS: 2.5"W @ .188" THK x 3.0"H @ .125" 22 2213 HOST STRUCTURE ANCHOR DESCRIPTION THK. 4x60 DRY S 4x64 DRY ST Q P " POWERS WEDGE-BOLT s�p�T4 C-CHANNEL: 2"W @ .156" THK x .563"H @ .250" 22 x 41 5 6 CONCRETE CONCRETE ANCHOR WITH 24" MIN. ��,1,j THK; HOLD RAIL IN-PLACE WITH -20x " GALtI. PREP AREA �-- --� EMBEDMENT & 3" MIN. EDGE DIST. �'�" 6"MAX. BOLT 102 13 20 - - _-- ------- u " GRADE 2 GALV. BOLT W/ ® __ ___ ----- SAE �� ,a CHLOR 24'x24' 14 w NUT & WASHER TO STRUCTURAL CROS5MEMBER: 1.25 x1.25 @ .093 THK GUTTER * A5 xx I o STEEL A36 STEEL MEMBERS (.27" MIN TUBING, 1"x1" @ .125" THK INNER TUBING; (2) 4-20 O 15 � O THICKNESS) THRUBOLTS TO INTERLOCK TUBES 0 ( I i 4, 11 F k x 70\ LAG SCREW W/ 34" MIN. 0VPOST: 1.5"0 @ .090" THK � 4 - WOOD THREAD PENETRATION TO WOOD NOTE: G.C. TO COORDINATE T 1 � (� FRAMING & MIN. 1" EDGE DIST. WITH LOCAL STRUCTURAL ^1"1 I 16 I I p rr ,� " (� IW 42 N ENGINEER TO ANALYZE ROOF BASE PLATE: 4x4 @ .250 THK.; ANCHORS PER °I°I-: 25 4� a• 0 ¢ G #14 ITW BUILDEX TEKS SELF- TYPE AND IMPOSED LOADS ANCHOR SCHEDULE 70 o w m DRILLING SCREWS W/ BANDED INDICATED AND PROVIDE 9 9 1 f Q PER COOLER BOX MANUFACTURER m STEEL Cn WACHER TO STRUCTURAL A36 ADDITIONAL DETAILS AS �' O EQUIPMENT SHEETS,THE BOX HAS A FLAME N STEEL MEMBERS ( " MIN. THK.) REQUIRED BY LOCAL CODE °� (m �l SPREAD RATING OF 20 AND A SMOKE 1 23 DEVELOPED RATING OF 450,WHICH MEETS j Q: LU CL rt-i=-- i� THE REQUIREMENTS FOR MAXIMUM FLAME 0- t� lq ;I SPREAD RATING OF 75 AND MAXIMUM to r112' SMOKE DEVELOPED RATING OF 450. W JQ COOLER ;----- m 4 r--------� CONDENSING UNIT MOUNTING DETAIL 1/2"=1'-0" � q. 1� m 25 20 [0J 104 1� 0011110 1' 7 3/ 5-1 8 101 X 201 L`-==-- J w o �r=_ �i w 4 iL 19 JI Q 0 00 - L= J N N _1 �o ,04 < DOU 5 10.1 10.1 lO.l 7.1 00, J 4 12 7 5 10 0 A4.0 FRONT LINE r-4 ___..,... ..,,.,,_,........, _ o '(y) (� O �N 3 LJ 3 27 L[ k�L (9 (y) OD 3 N J // t 0 e r� ' � II Ui o 4) U-0 LOBBY F F .x Z3 V 0) V)i= V LO 42 O LIJrn2 rn M K � ti G N x i Project Number P P M 16049. 1 Sheet Name EQUIPMENT PLAN NORTHSheet Number EQ EQUIPMENT PLAN 1/4"=1' 4 EQUIPMENT SCHEDULE NOTES I. SOME EQUIPMENT MODELS/SPECIFICATIONS BASED EQUIPMENT SUPPLIER SELECTED SCHEDULE BY STORE OWNER,TYPICALLY DONE AFTER PLANS ARE COMPLETED. EQUIPMENT EQUIPMENT SUPPLIER MAY SUBSTITUTE APPROVED EQUALS TO ITEMS LISTED IN THIS SCHEDULE. EQUIPMENT SELECTIONS ARE TO BE VERIFIED WITH STORE OWNER. ITEM SUPPL. INSTALL FINAL Ken McCracken, NO. BY BY CONNECT DESCRIPTION MANUFACTURER MODEL NO, REMARKS Architect 2. CONTRACTORS AND ALL SUBCONTRACTORS SHALL VERIFY ALL ELECTRICAL, 1 FSE FSE EC FRONTLINE ASSEMBLY WITH REFRIGERATED PIZZA MAKE-LINE RANDELL CUSTOM PER PLAN INCLUDES CUSTOM REFRIGERATED MAKELINES, SNEEZEGUARD AND SERVICE COUNTERS Architecture•Program Management•Permitting PLUMBING, MECHANICAL AND GAS REQUIREMENTS WITH MANUFACTURER'S EQUIPMENT DATA; CONTACT OWNER FOR EQUIPMENT SPECIFICATION SHEETS 16219 SE 12th STREET 3. ALL RESTROOM EQUIPMENT TO BE INSTALLED PER ARCHITECTURAL BARRIER 4 FSE FSE - PAN RACK WIN-HOLT AL-1820KD/HD - SUITE 202 STANDARDS 5 FSE FSE - STAINLESS STEEL CORNER GUARD WITH 2" RETURNS PACIFIC STAINLESS CUSTOM CUT-TO-FIT HEIGHT AS NEEDED WHEN INSTALLED UNDER SOFFIT OR HEADER VANCOUVER, WA 98683 4. INSTALL PROTECTIVE INSULATION OVER ALL EXPOSED PLUMBING UNDER LAVATORIES Contact:Martin D. Lakey 7 FSE FSE PC WALL MOUNT HAND SINK W/ KNEE VALVE AND FAUCET ADVANCE TABCO 7-PS-62 PROVIDE 5 8 x 247 PLYWOOD BACKING FROM 24 1A.F.F. TO 60 A.F.F. BEHIND HAND SINKS; SEE HAND SINK ELEV. 111/A4.0 (360)719-1952 AND REST OOM NAND SINK ACCESSORY FIXTURE SCHEDULE ON THIS SHEET ken.mccrackenQcomcast.net 7.1 FSE FSE STAINLESS STEEL SPLASH PANEL PACIFIC STAINLESS CUSTOM FOR USE ON PAINTED WALLS ONLY, NOT ON TILE, FRP OR VINYL SHEET - REFER TO ELEVATIONS 8 FSE FSE PC S.S. PREP TABLE SINK, WASTE VALVE, AND " " ADVANCE TABCO TKMG-30X PROVIDE 5 8 PLYWOOD BACKING FROM 36 A.F.F. TO 84 A.F.F. ® WALL BEHIND PREP SINK; DECK MOUNT FAUCET W 12 SWING SPOUT PREP SINK SEE E UIPMENT CUT SHEETS FOR INDIVIDUAL COMPONENT SPECS. S.S. 3-COMPARTMENT SINK W 18 DRAIN BOARDS OR T9-83-60-18RL PROVIDE 5/8-' PLYWOOD BACKING FROM 36 A.F.F. TO 84 A.F.F. ® WALL BEHIND 3-COMP SINK; 9 FSE FSE PC 24" DRAIN BOARDS WHERE REQUIRED ADVANCE TABCO g 4 -83-60-24 L SEE EQUIPMENT PLAN FOR DRAINBOARD SIZE: SEE EQUIPMENT CUT SHEETS FOR INDIVIDUAL COMPONENT SPECS. 9.1 FSE FSE PC PRE-RINSE UNIT W/ 16" SWING SPOUT T&S BRASS B-2194 - 10 FSE FSE EC WALK-IN COOLER BOX IMPERIAL CUSTOM PER PLAN ALL COOLER BOX SURFACES ARE 26-GA STUCCO GALVANIZED STEEL; INSTALLATION OF COOLER BOX PANELS AND DOORS BY FSE: ELECTRICAL CONNECTIONS BY EC 10.1 FSE FSE EC GLASS COOLER DOORS AND GRAVITY FLOW SHELVING CDS LEGACY SERIES COOLER DOOR LIGHTS TO BE SWITCHED WITH ACCENT LIGHTING; COOLER DOOR FRAME HEATERS TO BE UNSWITCHED SEE LIGHTING PLAN ON SHEET E2.0 o p 11 FSE OWN/GC EC/PC REFRIGERATION EQUIPMENT VARIES CUSTOM PER COOLER TECHNICIAN,ANOF H RED BY 1 OWNEROOREGCIPMENT AND(COORDINATE WITH CHARGING OWNER TEM NTH ELEC. NDFP MG.ANT BY LOCAL CONNEC ONS BYE CAND I PC. NOT HVAC t`�D A/ 12 FSE FSE EC 60—QT. MIXER G OBE HOBART SP62P2 E.C. TO VERIFY MAKE/MODEL WITH OWNER — ELEC. CONNECTIONS ON E1 AND E3 ARE TYPICAL FOR HOBART MODEL KENNETH J. RAGKE 13 FSE FSE P1 DOUGH SHEETER SOMERSET CDR-2000 E.C. TO VERIFY MAKE/MODEL WITH OWNER M .--i DOUGHPRO DPR3000 15 FSE FSE — S.S. WORK TABLE W/ UNDERSHELF ("SHEETER TABLE") ADVANCE TABCO FMG-30X — AM S, WA 16 FSE FSE — S.S. WORK TABLE W/ UNDERSHELF & CASTERS ADVANCE TABCO MG-30X — t�� license#5599 OF 19 FSE FSE - DOUGH BOX DOLLY NEW AGE 1195 - 01/18/17 20 FSE FSE DUNNAGE RACK NEW AGE 20XX - KiMt1434 Seal 22 FSE FSE - DRY STORAGE SHELVING METRO SUPER ERECTA - 23 FSE FSE - WALK-IN COOLER SHELVING METRO SUPER ERECTA COATED WITH METROSEAL III CORROSION-RESISTANT ANTIMICROBIAL EPDXY FINISH 24 FSE FSE - WALL SHELVING, SINGLE-LEVEL METRO SUPER ERECTA PROVIDE 5/8" PLYWOOD BACKING FROM 36" TO 84" A.F.F.; SEE EQUIPMENT PLAN FOR MOUTING HEIGHT 25 FSE FSE - WALL SHELVING, DOUBLE-LEVEL METRO SUPER ERECTA PROVIDE 5/8" PLYWOOD BACKING FROM 36" TO 84" A.F.F.; SEE EQUIPMENT PLAN FOR MOUTING HEIGHTS 26 FSE FSE - WALL ("PHONE STATION") SHELF ADVANCE TABCO WS-10-XX PROVIDE 24"x 24"x 5/8" PLYWOOD BACKING BEHIND PHONE SHELF AT 4 A.F.F TO CENTER OF BACKING; MOUNT TOP OF SHELF AT 44" A.F.F.• SEE POS STATION MOUNTING DETAIL ON SHEET A4 FOR REFERENCE 27 FSE GC - DROP SAFE CSS CS-2820 - 28 FSE FSE - EMPLOYEE LOCKERS WIN-HOLT WL-66 - 29 FSE FSE PC/Pl LAUNDRY CENTER - ELECTRIC KENMORE 61532 VERIFY MODEL AND REQUIREMENTS WITH OWNER; REFER TO DRYER VENT DETAIL 20 ON SHEET A4.0 VENT DRYER PER LOCAL CODE AND MANUFACTURER'S SPECIFICATION AND VERIFY LANDLORD APPROVAL OF VENTING METHOD 40 OWNER OWNER PI CHEESE GRATER - TABLE TOP PALAZZOLO GS-1 MANUAL - 0 J 41 OWNER OWNER PC/EC DISHWASHER W/ DISHTABLES AUTO-CHLOR A4ES/A5ES DOES NOT PRODUCE HEAT OR STEAM PER MANUFACTURER'S SPECIFICATIONS > < LU 42 OWNER OWNER - CLING WRAP DISPENSER ANCHOR PACKAGING MD24 - Z3 m w 50 PC PC PC MOP SINK/FAUCET, 2'x2' - NEW AS SPECIFIED OR EXISTING-TO-REMAIN SWAN MS-2424 SEE CUT SHEETS FOR ALL COMPONENTS; PROVIDE 5/8" PLYWOOD BACKING FROM FLOOR TO 72" A.F.F. 0 WALL BEHIND NEW MOP SINK N V w iE 26 � w > w UJ CL (D Cx i,_ 2 Z w J W U = m 51 PC PC PC/EC WATER HEATER, GAS TANKLESS RINNAI RL751 180 GPH RECOVERY @ 1007 RISE `O 'O LU !— N O 00 52 PC PC PC TOILET - NEW AS SPECIFIED OR EXISTING-TO-REMAIN KOHLER K3979/K3979-RA SEE CUT SHEETS FOR ALL COMPONENTS; EXIST. FIXTURE MAY REMAIN / BE REUSED IF IN GOOD CONDITION AND AGAAG-COMPLIANT a N C 53 PC PC PC RESTROOM SINK - NEW AS SPECIFIED OR EXISTING-TO-REMAIN KOHLER K-2035-4 SEE CUT SHEETS FOR ALL COMPONENTS; EXIST. FIXTURE MAY REMAIN / BE REUSED IF IN GOOD CONDITION AND AGAAG-COMPLIANT FIXTURES AND DECOR SCHEDULE ITEM SUPPL. INSTALL FINAL NO. BY BY CONNECT DESCRIPTION MANUFACTURER MODEL NO. REMARKS IV D OWNER GC - MENU PANELS, WALL-MOUNTED DECOR SUPPLIER CUSTOM MILLWORK MOUNTING HARDWARE PROVIDED BY DECOR SUPPLIER; REFER TO INSTALLATION INSTRUCTIONS BY DECOR SUPPLIER (� D F OWNER GC - "CREATE FRESH" (HOW-TO-ORDER) BOARD, WALL-MOUNTED DECOR SUPPLIER CUSTOM MILLWORK REFER TO INSTALLATION INSTRUCTIONS BY DECOR SUPPLIER CV) o � G OWNER GC - STATE GRAPHIC DECOR SUPPLIER CUSTOM MILLWORK REFER TO INSTALLATION INSTRUCTIONS BY DECOR SUPPLIER ON INSTALL AS SHOWN ON REFLECTED CEILING PLAN AND PER INSTALLATION INSTRUCTIONS PROVIDED BY DECOR SUPPLIER; Q O.g w H OWNER GC - SUSPENDED DIMENSIONAL LETTERS DECOR SUPPLIER CUSTOM MILLWORK REFER TO SUSPENDED DIMENSIONAL LETTERS DETAIL 12/A4.0 In J OWNER GC - DIMENSIONAL LETTERS AND ARTWORK DECOR SUPPLIER CUSTOM MILLWORK REFER TO INSTALLATION INSTRUCTIONS BY DECOR SUPPLIER U K OWNER GC - "CREATE-TAKE-BAKE" MURAL DECOR SUPPLIER CUSTOM MILLWORK START INSTALLATION AT TOP OF BASE AND CUT-TO-FIT FROM TOP OF MURAL IF NEEDED ® L OWNER GC P.I. OPEN SIGN DECOR SUPPLIER CUSTOM MILLWORK REFER TO INSTALLATION INSTRUCTIONS BY DECOR SUPPLIER AND TO OPEN SIGN DETAIL 14/A4.0 .0 M OWNER OWNER OWNER POS TERMINAL NCR P1530 INSTALL ELEC./LOW-VOLT. UTILITIES PER 4/E1.0 L0 N OWNER OWNER OWNER POS CALL-IN TERMINAL (WALL-MOUNTED) NCR P1530 INSTALL ELEC./LOW-VOLT. UTILITIES AND WOOD BACKING PER 4/A1.0, 4/E1.0 AND 15/A4.0 Q Imo. P OWNER OWNER - MANAGER DESK - - PROVIDE 5/8" PLYWOOD BACKING FROM 54" A.F.F. TO 102" A.F.F. 0 WALL BEHIND MANAGER DESK � Q GC GC - EMPLOYEE COUNTER CUSTOM COORDINATE SIZE/STYLE WITH OWNER RESTROOM AND HAND SINK ACCESSORY FIXTURESGC TO OBTAIN ALL FIXTURES ON THIS SCHEDULE FROM INSTALLED LOCATIONS CURTIS RESTAURANT EQUIPMENT, UNLESS NOTED OTHERWISE ITEM FINAL PUBLIC EMPLOYEE FRONT BACK NO. SUPPLY INSTALL CONNECT DESCRIPTION MANUFACTURER MODEL NO. RESTROOM RESTROOM HAND SINK HAND SINK REMARKS R1 PMI OPS GC - TOWEL DISPENSER, SENSOR-OP, SURFACE-MOUNT, DEEP RED CINTAS SIGNATURE SERIES *010 . v,.1 ✓ Project Number PPM 16049. 1 R2 PMI OPS GC - SOAP DISPENSER, MANUAL-OP, SURFACE-MOUNT, DEEP RED CINTAS SIGNATURE SERIES y/ y0'" V001 *00, R3 PMI OPS GC - TOILET PAPER DISPENSER, SURFACE-MOUNT, DEEP RED CINTAS SIGNATURE SERIES R4 GC GC - TRASH RECEPTACLE, STAINLESS STEEL, RECESSED-MOUNT, WITH COVER BRADLEY 344-65 y/ Sheet Name R4 GC GC - TRASH RECEPTACLE, PLASTIC, FLOOR-STANDING, WITH COVER RUBBERMAID FG307120 �/""� EQUIPMENT R5 GC GC - GRAB BARS - 18", 36", 42% STAINLESS STEEL, CONGEALED-MOIUNT BRADLEY 812 SERIES Vol' ✓ LOCALLY-SOURCED EQUIVALENT MAY BE SUBSTITUTED AND DECOR R6 JGC GC - MIRROR, STAINLESS STEEL FRAME, 18"X36" BRADLEY 781-1836 Vol" y/'' LOCALLY-SOURCED EQUIVALENT MAY BE SUBSTITUTED R7 GC GC BAG SHELF, STAINLESS STTEEL, 18GA, 5"x16" BRADLEY 755-16 v0*1 LOCALLY-SOURCED EQUIVALENT MAY BE SUBSTITUTED SCHEDULES R8 GC GC - COAT HOOK, SATIN STAINLESS BRADLEY 9134 vw- y/ LOCALLY-SOURCED EQUIVALENT MAY BE SUBSTITUTED R9 GC GC - GLOVE DISPENSER, STAINLESS STEEL,.3-BOX SAN JAMAR G0806 R9 GC GC - GLOVE DISPENSER, PLASTIC, 3-BOX SAN JAMAR G0805 Sheet Number EQ1 ,91 GENERALNOTES ANY QUESTIONS OR REQUESTS FOR SUBSTITUTIONS SHOULD BE SUBMITTED THRU THE GENERAL CONTRACTOR. THE GENERAL 1. WELDING OR DRILLING OF STRUCTURAL MEMBERS IS NOT ALLOWED. CONTRACTOR SHOULD THEN ISSUE AN OFFICIAL REQUEST FOR INFORMATION TO THE ARCHITECT. 2. ALL DIMENSIONS SHOWN ON PLANS ARE MEASURED FROM FINISHED SURFACES, CEILING Ken McCracken, TO THE CENTER LINE OF OUTLETS AND PULL BOXES. THE ELECTRICAL CONTRACTOR SHALL HIGH-SPEED DATA (HSD) PROVIDER:STORE OWNER IS TO OBTAIN HIGH-SPEED MAKE ALLOWANCES FOR FINISHES. Architect DATA CONNECTION/SERVICE WITH A MIN. 15Mbps DOWNLOAD AND 2Mbps Architecture-ProgramManagement-Permitting UPLOAD TO SATISFY NCR REQUIREMENTS FOR POS SYSTEM 3. PROVIDE ADDITIONAL POWER OUTLETS AS NECESSARY TO COMPLY WITH CODE REQUIREMENTS. 16219 SE 12th STREET 4. E.C.TO VERIFY,WITH OWNER, LOCATION FOR CONVENIENCE OUTLETS AND TELEPHONE SUITE 202 TERMINALS: CABLES FROM POSALS:TERMINATE 4 LINES OUTLETS. REFER TO ARCHITECTURAL PLANS FOR KITCHEN EQUIPMENT DESIGNATIONS. VANCOUVER, WA 98683 T TERMIN AT PATCH PANEL TO/FROM DMARC Contact: Martin D.Lakey TELCO 5. ALL WORK,AND MATERIALS SHALL BE 1N FULL ACCORDANCE WITH THE LATEST EDITION OF G THE NATIONAL ELECTRICAL CODE (N.E.C.) AND FEDERAL,STATE AND LOCAL CODES THAT (360)719-1952 ( APPLY,MECHANICAL AND ELECTRICAL DESIGN CRITERIA. ken.mccracken@comcast.net (2) CAT-5E RUNS TO TELCO 6. ALL WIRE SIZES TO BE#12 UNLESS NOTED OTHERWISE. ALL CONDUIT TO BE 1/2"UNLESS 6 \ UNISEX DMARC ELSEWHERE IN BLDG.; FIELD �l RESTROOM COAX DSL NOTED OTHERWISE. E CONNECTION BISCUIT VERIFY LOCATION AND CONDITIONS 4 BOX** BOX** 7. TO INCREASE SAFETY TO MAINTENANCE AND SERVICE PERSONNEL WORKING ON i BY E.C. BY E.C. CEILING GRID ELECTRICAL APPLIANCES, EACH MULTI WIRE BRANCH CIRCUIT WITH SHARED NEUTRAL 17- SHALL BE PROVIDED WITH A MEANS THAT WILL SIMULTANEOUSLY DISCONNECT ALL Q LINE ** MAY BE SAME OR SEPARATE UNGROUNDED CONDUCTORS IN ACCORDANCE WITH REQUIREMENTS ARTICLE 210.4 OF \ \ �, A-20 Z CARD BUNDLE 4 Wa) PROVIDERS/ HE N.E.C. \ / < VED A,�C -<M CONNECTIONS DEPENDING ON A E14 i� A-4 8. ALL OUTLET FACEPLATES IN THE STORE TO BE WHITE WITH WHITE RECEPTACLES, EXCEPT FOR NOT A PART Pp SERVICE AVAILABILITY AND �. 4 KENNETH J. BLACK RECEPTACLES FOR DEDICATED CIRCUITS AS NOTED IN THE CONSTRUCTION NOTES. A-10,12 4,� STORE OWNER PREFERENCE. / \ 48" M RACKE F 9. PRIOR TO BID,THE CONTRACTOR SHALL REVIEW THE MECHANICAL, ELECTRICAL AND / E13 48" 12 0 LINES 1/2/3 TO CALL-IN STATION KITCHEN EQUIPMENT DRAWINGS. THE CONTRACTOR SHALL INCLUDE IN HIS BID ALL _ AM S, WA RELEVANT WORK IN THE ENTIRE SET OF DOCUMENTS AND REPORT ALL DISCREPANCIES r), License#5599 r- m _ AND MANAGER DESK FOR STORE BETWEEN THESE DRAWINGS TO THE ENGINEER PRIOR TO BIDDING FOR CLARIFICATION. IF rn r• PHONES; REF. DETAILS i b/-. 4 �cn?� z N to m o DISCREPANCIES REMAIN UNRESOLVED DUE TO A SHORT TIME FRAME,THE CONTRACTOR V OF X M x I o A `} SHALL INCLUDE THE MOST WORK AND THE HIGHER COSTS IN THE BID. SOLUTIONS TO v oo M -� m LINE 4 TO SERVICE COUNER UNREPORTED DISCREPANCIES WILL BE DETERMINED BY THE ARCHITECT/ENGINEER,WITH t MANAGER "�' ro� o ASSEMBLY FOR CREDIT CARD NO ADDITIONAL COMPENSATION DUE TO THE CONTRACTOR. jl '"� �3 7/1$�, c n 0 chi TERMINAL iaMn aaa _ LINE 4 TO FAX/DIAL-UP FSeal BACKUP AT MANAGER DESK; CONSTRUCTION NOTES M-;u PORTST PORTS REF. DETAIL 16/-. E p p A4 SWITCH ELECTRICAL ROUGH-IN AND FINAL CONNECTIONS TO ALL FOOD SERVICE EQUIPMENT G ROUTER 1 AND FIXTURES AS SHOWN ON ELECTRICAL DRAWINGS SHALL BE BY ELECTRICAL D D DVRN/VgRP FIREWALL �o 6Y 67HER� 13Y OTHERS o 0 op CONTRACTOR. f A-9 0E9 L.E.D. READOUTS LE.D. READOUTS e JUNCTION BOX IN COOLER DOOR FRAME PROVIDES FOR (2) CONNECTIONS: 7 A-30 as o0 -FOR COOLER DOOR LIGHTING TO BE SWITCHED VIA SWITCH 'c'. PREP AREA A-28 -FOR HEATER IN COOLER DOOR FRAME,TO BE NON-SWITCHED AND ALWAYS ON. CORD BUNDLE CORD BUNDLE POWER STRIP ELECTRICAL CONTRACTOR TO MAKE BOTH CONNECTIONS. CONY. DUPLEX FOR OTHER CONNECTION TO CONDENSING UNIT ON ROOF. 208V/1 PH,20 MCA, VERIFY EXACT 48 A-42 A-40 :(:D]DATA BOARD EQUIPMENTSTORE EQUIPMENTLOCATION IN FIELD. SEE EQUIPMENT SCHEDULE FOR ADDITIONAL INFORMATION. A-8 DEDICATED CIRCUIT FOR CLOTHES WASHER &DRYER OUTLETS-VERIFY REQUIREMENTS WITH OWNER. SEE E25 E2b EQUIPMENT SCHEDULE FOR DETAIL. A-22,24 I EXISTING R.T.U.-6:208-230/60/3PH, EXISTING 3-POLE DISCONNECT SWITCH, EXISTING GFI E17 WP RECEPTACLE AT UNIT. LOCATION SHOWN FOR REFERENCE ONLY, VERIFY DUCT 11 1 SMOKE DETECTOR, PROVIDE NEW AS REQUIRED. SEE EQUIPMENT SCHEDULE FOR I I 3 z0 < ADDITIONAL INFORMATION. #10 E1 `�� j NEW GAS,TANKLESS WATER HEATER: SEE EQUIPMENT SCHEDULE FOR ADDITIONAL A-1,3,5 0 4INFORMATION. w :D "' A-37,39,41 #10 "' "' ON ROOF � O7 PROVIDE BLACK RECEPTACLE FOR THIS CIRCUIT AND LABEL"P.O.S.SWITCH ONLY". E21 \� GFCI WP w L,6 WP i-r--R-�i W P >UJ w 0 ii ii i, A-7 ON ROOF 8 ?PER N.E.C.210.8(B)(2), ALL 15A AND 20A RECEPTACLES IN KITCHEN AREA TO BE G.F.I. LL U-_ -� u ., zJ a COOLER ��=n—R-�� 5 lu Q PROVIDE NEW T-STAT IN LOCATION SHOWN, REUSE AND RELOCATE EXISTING T-STAT IF IN 1 I a4 ;� ii ii i; U z co �I Q X 20 L-------� E19 DATA BOARD DETAIL N.T.S. 14 9 GOOD WORKING ORDER. ��=.�=_R=�-t E RTU A-31,33,35 li ii ii i' 208/230V 3PH 1 AT EACH BUILDING SIGN-CIRCUIT VIA TIME CLOCK/PHOTOCELL. PHOTOCELL TO TURN E10 t� I� �� �� ii CN 0 00 THIS SYMBOL DESIGNATED BY D ��_"-_-='� EQUIPMENT SCHEDULE 10 SIGN ON AND TIME CLOCK TO TURN SIGN OFF. VERIFY LOCATION-SEE DETAIL 16/E2.1 t, (A ____ ::— p N 1_- FOR SCHEMATIC DETAIL. DISCONNECT TO BE WITHIN SIGHT OF SIGN OR CONTROLLER PER C a o ZA I1 1! �! �; �- 3 VOLTS & POWER SOURCE TYPE MOUNTING N.E.C.600.6. : ITEM NO. DESCRIPTION LOAD KW PHASE PANEL C/B FEEDER SIZE CONNECTION HEIGHT(IN.) NOTES THIS CRITERIA SHALL APPLY TO THE SIGN AS FOLLOWS: A-26 $o El COOLER-ROOM CONDENSING UNIT 3.30 208/1 A-22,24 25/2 1/2"C-2 #10 DISC.SWITCH VERIFY 1,6 1. IF SIGN IS EXISTING, E.C.TO DO FINAL CONNECTIONS. 56 2 2. IF SIGN 1S NEW,SIGN VENDOR TO DO FINAL CONNECTIONS. 15" M1 M1 M1 M1 E3 MAKELINE COOLER #2 1.20 120/1 A-21 20/1 1/2"C-2 #12 C &P 12" 1, 5 Elg E4 MAKELINE COOLER #3 1.20 120/1 �A-25 20/1 1/2"C-2 #12 C &P 12" 1, 50 , 511 FLUSH MOUNT OUTLET IN CEILING MATERIAL. CIRCUIT AND CONTROL VIA SWITCH'c'. v v E5 P.O.S. #1 0.40 120/1 A-17 20/1 1/2"C-2 #12 C & P 30" 2 9 E6 P.O.S. #2 0.40 120/1 _ A-17 20/1 1/2"C-2 #12 _ C &P 30" 2 12 MAKE NECESSARY CONNECTIONS TO EXHAUST FAN FOR COMPLETE INSTALLATION. Eb E7 CIRCUIT TO ADJACENT LIGHT FIXTURE. RECONNECT EXISTING LIGHTING AS REQUIRED. E7 P.O.S. #3 0.40 120/1 A-17 2011 1/2"C-2 #12 C &P 30" 2 --- FRONT LINE �`, i < �; % O O A-17 E8 REFRIGERATED DISPLAY CASE 1.60 120/1 A-19 20/1 1/2"C-2 #12 C & P 15" E9 P.O.S.COMPUTER 0.40 120/1 A-30 20/1 1/2"C-2#12 C &P 39' 2 0 o A-6,21,25 N 0 15p E10 P.O.S. #5 0.40 120/1 A-30 20/1 1/2"C-2#12 C &P 49' 2 A 15" _ 1201 201 12 2#12 1 LOW-VOLTAGE NOTES A-2 .5 E12 CLOTHES WASHER 1.20 / A-14 ! / C &P 4$ E13 CLOTHES DRYER 5.00 208/1 A-10,12 30/2 1/2"C-2 #10 6-30R 4$" 4,5,6 1. ELECTRICAL OR LOW-VOLTAGE CONTRACTOR SHALL BE RESPONSIBLE FOR A-25 A' o o.�� 611-- E13 LOW-VOLTAGE WIRING AND DEVICES. E4 E3 x "x `� 0 �t�l E14 WATER HEATER (GAS) 0.60 120/1 A-16 20/1 1/2"C-2 #12 C &P 96" 3, 6 ro (ACy CN `/�' i� VIA SWITCH 'c' A-13 E15�^ 60 QUART MIXER 3.60 208/3 A-31,33,35 20/3 1/2"C-3 #12 NEMA # L-15-20 15" 4, 5, 6 LO 1r �l -VOLTAGE LEGEND `� 11 15" ,� _ � ii E17 DOUGH SHEETER 1.80 120/1 A-8 20/1 1/2"C-2 #12 C & P 48" 1,5 _ ;- u E19 ROOF TOP UNIT (R.T.U.) EXIST EXIST _ A-1,15 EXIST EXISTING EXISTING EXISTING 4i u Ln `+' SERVICE COUNTER ACCESS: , u 15 * •U 0 E21 CHEESE GRATER 3.00 208/3 A-37,39,41 20/3 1/2"C-3 #12 NEMA # L-15-20 CLG.MTD. 4, 6 (2) 3/4"EMT CONDUIT IN WALL; RUN VERTICAL FROM 6"ABOVE CLG. GRID AND a O TERMINATE AT OPEN J-BOX MOUNTED FLUSH WITH FACE OF WALL AT MOUNTING \" 0 ® (D C E25 FUTURE DISHWASHER 0.40 120/1 A-42 20/1 1/2"C-2 #12 C & P 38" 4, 5, 6 HEIGHT SHOWN ON PLAN. FOR PHONE/DATA CABLE ONLY. A-6 LOBBY 1-19 y� " n - - E26 DOUGH ROUNDER - 120/1 A-40 20/1 1/2"C-2 #12 C &P CLG. MTD. 1, 5 1�0 �`J -+_ > SERVICE COUNTER ASSEMBLY: V� ES \ - GENERAL NOTE:ALL 120 VOLT 15 AND 20 AMP OUTLETS IN KITCHEN/FOOD PREP AREA TO BE G.F.I. PROTECTED PER N.E.C.210.$(8)(2). INSTALL SURFACE-MOUNTED DUAL-JACK RJ45 BISCUIT BOX AT EACH POS TERMINAL 1 V)i= B LOCATION;LABEL JACKS TO CORRESPOND WITH PATCH PANEL JACK NUMBER. Q FUTURE LO EQUIPMENT NOTES: INSTALL SURFACE-MOUNTED SINGLE-JACK RJ-14 BISCUIT BOX AT TELEPHONE LINE 4 0 I VERIFY EQUIPMENT DETAILS WITH ARCHITECT LOCATION (FOR BACK-UP CREDIT CARD TERMINAL). ^ A-17 2 PROVIDE BLACK RECEPTACLE ON DEDICATED SINGLE PHASE CIRCUIT FOR EACH P.O.S.TERMINAL; LABEL AS"P.O.S.TERMINAL ONLY". POS STATION: <$> T4 A-6 A-2 VVV o 3 PROVIDE LOCK OFF DEVICE. (1) 3/4"EMT CONDUIT IN WALL;RUN VERTICAL FROM 6"ABOVE CLG. GRID AND RJ45x2 C TERMINATE AT J-BOX WITH FLUSH-MT. DUAL-JACK RJ45 FACEPLATE AT 40"A.F.F. LABEL A-15 11 11 10 _ 4 VERIFY EQUIPMENT IN FIELD. JACKS TO CORRESPOND WITH PATCH PANEL JACK NUMBER. TERMINATE RJ-14 PHONE E5 5 PROVIDE CORD ND PLUG FOR APPLIANCE. LINES 1/2/3 WITH DUAL-PORT FLUSH-MOUNT KEYSTONE FACEPLATE; REF. DETAIL D2/E1 - -- -- AND 15/A4. 6 PROVIDE EQUIPMENT GROUNDING CONDUCTOR PER N.E.C.250. MANAGER DESK: O (1) 3/4"EMT CONDUIT IN WALL; RUN VERTICAL FROM 6"ABOVE CLG. GRID AND TERMINATE AT J-BOX WITH FLUSH-MT. QUAD-JACK RJ45 FACEPLATE AT 38"A.F.F. LABEL JACKS TO CORRESPOND WITH PATCH PANEL JACK NUMBER. TERMINATE RJ-14 PHONEf Project Number LINES 1/2/3/4 WITH 3-PORT FLUSH-MOUNT KEYSTONE FACEPLATE; REF. DETAIL D3/El. V,PP A A 16049. 1 69•04 l LINE 1/2 O ACCESS TO DATA BOARD:<E> t ' C� 1 PROVIDE HOLE AND GROMMET IN CEILING GRID ABOVE DATA BOARD TO ALLOW CABLE RUNS FROM CEILING TO TERMINATE AT NETWORK PATCH PANEL ON DATA �rT Sheet Name p LINE 3 BOARD;REF. DETAIL DI/E1. REFERENCE ONLY FLOO R LINE 4 FAX DATA BOARD: NOT APPROVED WITH THIS PERMIT AND DIAL-UP PLYWOOD DATA BOARD PROVIDED BY G.C. (REF. I/A1);COMPONENTS TO BE BACKUP PROVIDED/INSTALLED PER DET.D1/E1. POWER `V✓ Y V OWER R NETWORK CABLING: PLAN ® DASHED LINES INDICATE INSTALLATION OF CAT-5E DATA CABLE FROM EACH RJ45 O JACK,THROUGH CONDUITS AND TERMINATING AT 24-PORT NETWORK PATCH PANEL MOUNTED ON DATA BOARD. RUN CABLE ABOVE GRID IN COMPLIANCE WITH LOCAL P.O.S.STATION MANAGER'S DESK CODES; USE PLENUM-RATED CABLE IF CODE REQUIRES. NORTH Sheet Number E1 .0 PHONE JACKS N.T.S. 1 b ELECTRICAL/LOW VOLTAGE PLAN SIGN Ken McCracken, Architect INTERIOR LIGHTING Architecture-Program Management-Permitting CIRCUITS 16219 SE 12th STREET PHOTOCELL FOR SUITE 202 SIGN TURN ON VANCOUVER, WA 98683 Contact:Martin D. Lakey PC LEVITON RE4BD-104 EZ-MAX RELAY CONTROL PANEL (360)719-1952 WITH INTERNAL TIMECLOCK ken.mccracken@comcast.net AND BATTERY BACKUP FOR LIGHT CONTROL \� UNISEX O ` 4 RESTROOM Ex 106 xi A-1 \ / X2' A-3 \ / A-4 u : fl ARC SPARE NOTA ART A-4a A-4a �I . . . . f� x C KENNETH J. M RACKE .--� AM S,WA LIGHTING CONTROL DIA. N.T.S. 3 - J,�' License#5599 INSTALL SWITCHES IN �I 5-GANG WALL PLATE ++ MANAGER AND APPLY LABELS WITH 1 ( 103 01/18/17 VERBIAGE AS SHOWN SWITCH `a' A-4b A-4a /� C i KJM/1434 ----- SWITCH 'b' ---- C ___.-..- A-4 ___ Seal DIRECTION OF -- SWITCH'c' APPROACH .— A-4a ' A-4b SWITCH 'd' NL c PREP AREA — o 102 — F. — ZO O O -o O O wcn `L u _ 11 X2 - _- ( Uv) ` A-4 - F - U� C ¢O A-4b SWITCH 'e' ' p J SWITCH ORDER REFLECTS APPROACH ) N < FROM THE LEFT. IF APPROACH IS FROM LU co m THE RIGHT,THEN THE SWITCH ORDER IS ( A-26 6 � D TO BE REVERSED. F w r A-4b A-4a ' TYP. ' sn LU � US REFER TO LIGHTING PLAN THIS SHEET `U a FOR ADDITIONAL INFORMATION - ___. __. _ _..._ . _ LU J CL C7 C = z COOLER J a 104 UUJ LIGHTING SWITCH DIAGRAM N.T.S. 4 A-4a 1 or x 20' 10 10 UJ __ __ ____ _ I _.__F__ F____ _.__ LIGHTING FIXTURE LEGEND edcb'a� A4 1 5- - SYMB. DESC. MANUF. MODEL# BULB PROVIDED BY A-4 — b —� 2'-0"x 2'-0" GENESIS ¢ A GLS-LG2-35- 36W r RECESSED W/ LIGHTING OWNER i PUB-UNV2-1400 3500K LED ACRYLIC LENS SOLUTIONS D� L_ A-4c � — B 2'-0"x 2'-0" GENESIS GLS-LG2-35- 45W RECESSED W/ LIGHTING OWNER D D D p ACRYLIC LENS SOLUTIONS PUB-UNV2-1670 3500K LED B j N A-4c A-4c 6A-4c C 2'-0,,x 2'-0" GENESIS ---- A-4d - - _ GLS-LG2-40- 45W B 1:7 B RECESSED W1 LIGHTING OWNER FRONT LINE ACRYLIC LENS SOLUTIONS PUB-UNV2-1670 4000K LED — — — — — — — — — - - GENESIS LIGHT: A-4e A-4d - A-4e N 6' DIRECTIONAL 13AW --- LIGHT MODULE LIGHTING GLS-DEB6-3K-WH 3000K LED OWNER ---�p ( o D SOLUTIONS HOUSING: 17002 _ A-4c- D O GENESIS LIGHT: ' w (y) 6"RECESSED 13AW LIGHTING GLSb-3K-WH OWNER --- D `" O �� E DOWNLIGHT SOLUTIONS HOUSING: 17002 3000K LED A-4c D_._ ___ .. __ N O -JD - LIGHT: A A AO4c- \ ' h 1 VAPOR PROOF 26W SB CFL LAMP COOLER BOX �,�, tT ® COOLER LIGHT KASON HOUSING: CFL MANUF. -_-{}p A-4e _ A-4d A-4e �^ __ Q U F FIXTURE 806LG0000 A-4c i NL (} EXTERIOR }--( Q ► INDUSTRIAL - - E.C. -_-()D ' 3 A LOBBY p z \ EX EXIT LIGHT A-4c Q o A-4 A-4c F- x \ V? LIGHTING PLAN NOTES EXIT LIGHT LITHONIA EDG 1 120 ELN RED LED EXISTING/E.C. t7 F— x1 _- -- __ -. __ -- __-- ___ -_ _ D o 0 WALL EMERGENCY 18102 CIRCUIT EXIT&EMERGENCY LIGHTS AHEAD OF SWITCHING. PROVIDE WITH A MINIMUM X2 NICOR (2) 5.4W E.C. ;A-4c _ ¢ 1 0 LIGHT WHITE HOUSING A-4d BATTERY RUN TIME OF 90 MINUTES. INSTALL ON CEILING PANELS AT LOCATION SHOWN. CEILING 55 V D �}D .. _- _ 2 PROVIDE SWITCHES ON THE WALL FOR LIGHT CONTROL. SEE DETAIL 14/--. PHOTO SENSOR WATT STOPPER LS-301 A-4c A-4e A-4 A-4d X2 'A-4c f� PS POWER PACK WATT STOPPER BZ-50 E.C. xi t 3 � ELECTRICAL CONTRACTOR SHALL CIRCUIT NIGHT LIGHT FIXTURE AHEAD OF SWITCH. EX � ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL EXTERIOR EMERGENCY FIXTURE WITH O r 4 4 BATTERY PACK AS REQUIRED. VERIFY REQUIREMENT WITH LANDLORD REPRESENTATIVE WALL SWITCH Fes' Project Number PRIOR TO BID. MAINTAIN CONNECTION IF EXISTING. OS OCCUPANCY WATT STOPPER PW-101 E.C. <5> REFER TO REFLECTED CEILING PLAN FOR EXACT(DIMENSIONED) LOCATION OF ACCENT SENSOR P PM 16049. 1 LIGHTS. LIGHTS IN COOLER BOX PROVIDED BY COOLER BOX MANUFACTURE AND INSTALLED r �r Sheet Name BE ELECTRICAL CONTRACTOR.-TYP.QUANTITY (5). REFERENCE ONLY GENERAL LIGHTING NOTES NOT APPROVED WITH THIS PERMI LIGHTING 1. WELDING OR DRILLING OF STRUCTURAL MEMBERS IS NOT ALLOWED. PLAN 2. VERIFY FIXTURE LAYOUT COMPLIES WITH BUILDING CODE f 3. VERIFY EXIT SIGN, EMERGENCY LIGHT REQUIREMENTS AND LAYOUT COMPLY WITH LOCAL CODE. NORTHSheet Number E2 .00 ELECTRICAL LIGHTING PLAN (J4 ELECTRICAL SYMBOLS ELECTRICAL SCHEDULE NOTES ELECTRICAL PANEL SCHEDULE JUNCTION BOX 1. ELECTRICAL CONTRACTOR SHALL VISIT SITE AND NOTIFY ENGINEER OF ANY SINGLE POLE SWITCH DISCREPANCIES PRIOR TO BID. EXISTING EQUIPMENT TO BE REUSED WILL BE REQUIRED Q SWITCH GANG BOX AND COVER TO SATISFY THE REQUIREMENTS OF THE CURRENT NEC WITH REGARDS TO RATING, TELEPHONE/DATA OUTLET ® Ken McCracken, IDENTIFICATION, USE,WIRE, BENDING SPACE, ETC.AS IF THEY WERE NEW. ® PLATE (VERIFY EXACT NUMBER OF At'ChlteCt ALARM KEY PAD SWITCHES) 225 AMP FRAME MAIN LUGS ONLY 2. PROVIDE NEW CIRCUIT BREAKERS IN PANELS AS REQUIRED. MATCH EXISTING Architecture•Program Management•Permitting OT TRANSFORMER O WALL MOUNTED OCCUPANCY EQUIPMENT WITH RESPECT TO MANUFACTURER AND RATING. NEW120/208V,3 PHASE,4 WIRE BRANCH CB'S;PLUG-ON,SIZE AS INDICATED SENSOR 16219 SE 12th STREET WP WEATHER PROOF PANEL (FLUSH OR SURFACE MOUNT 3. PROVIDE CIRCUIT BREAKERS IN PANEL AS CALLED FOR AND REQUIRED. MATCH PANEL A 42 CIRCUIT,RECESSED.NEMA 1 INTERRUPTING RATING:PER UTILITYCO.REQUIREMENTS SUITE 202 AS SHOWN) COMPONENTS TO PANEL. VANCOUVER, WA 98683 TQ TIMECLOCK (J JUNCTION BOX 4. ANY QUESTIONS OR REQUESTS FOR SUBSTITUTIONS SHOULD BE SUBMITTED THROUGH F T THE GENERAL CONTRACTOR. THE GENERAL CONTRACTOR SHOULD THEN ISSUE AN Contact: Martin D. Lakey � DUPLEX RECEPTACLE OFFICIAL REQUEST FOR INFORMATION TO THE ARCHITECT. (360)719-1952 �GFI DUPLEX RECEPTACLE WITH GROUND DESIGNATION CKT.BRKR. VOLT-AMPS CKT.BRKR. DESIGNATION ken.mccracken@comcast.net FAULT INTERRUPTER `"IRE SERVES SERVES WIRE u CKT. PANEL AMP POLE AWG LOAD A B C LOAD AWG AMP POLE PANEL CKT. pft DOUBLE DUPLEX RECEPTACLE CVO. SPACE SPACE No. PENDANT RECEPTACLE 1 2,880 4,080 1,200 EXTERIOR SIGN #12 20 1 2 2 RECEPTACLE,2 POLE,208 V. 1 3 30 3 #10 E19 RTU 2,880 4,180 1,300 SALES/BACKROOM LIGHTS/EXH FAN #12 20 1 4 4 O X Q 5 2,880 4,480 1,600 P.O.S. E5, E6, E7, 8, F.Q.H. PHONE #12 20 1 6 6 X �} p t DISCONNECT SWITCH 7 7 20 1 #12 RTU SERVICE RECEPTACLE 180 1,980 1,800 E17 DOUGH SHEETER #12 20 1 8 8 �yED ARC TELEPHONE OUTLET 9 9 20 3 #12 GENERAL RECEPTACLES #1 540 3,040 2,500 10 KENNETH J. E13 CLOTHES DRYER #10 30 2 10 M RACKE ..-1 Q DATA OUTLET 11 11 20 1 #12 GENERAL RECEPTACLES #2 720 3,220 2,500 12 13 13 20 1 #12 CREATE FRESH WALL 360 1,560 1,200 E12 CLOTHES WASHER #12 20 1 14 14 AM S, WA X 15 15 20 1 #12 CEILING RECEPTACLES 360 360 SPARE 1 16 16 F License#5599 17 17 20 1 #12 POS RECEPTACLE E5, E6, E7 1,440 1,440 SPARE #12 20 1 18 18 OF O� 19 19 20 1 #12 E8 REFRIGERATED DISPLAY CASE 1,572 2,172 600 El GAS WATER HEATER 1 20 20 21 21 20 1 #12 E3MAKELINE #2 1,176 2,840 1,664 22 01/18/17 E1 COOLER CONDENSING UNIT #10 25 2 22 23 23 20 1 #12 SPARE 1,664 1,664 24 KJM11434 25 25 20 1 #12 E4 MAKELINE#3 1,176 1,296 120 COOLER WALKIN LIGHTS #12 20 1 26 26 Seal 27 27 20 1 #12 SPARE 600 600 COOLER WALKIN COIL #12 20 1 28 28 29 29 20 1 #12 SPARE 1,600 1,600 P.O.S. E10, E20, DATA BOARD, P.O.S.COMPUTER #12 20 1 30 30 31 1,200 1,200 SPARE #12 20 1 32 32 31 33 20 3 #12 E15-60 QT MIXER 1,200 1,200 SPARE #12 20 1 34 34 35 1,200 1,200 SPARE #12 20 1 1 36 36 37 1,000 1,000 SPARE #12 20 1 38 38 37 39 20 3 #12 E21-CHEESE GRATER 1,000 1,000 E26-DOUGH ROUNDER #12 20 1 40 40 41 1 11,000 2,600 1,600 E25-DISHWASHER #12 1 20 1 42 42 TOTAL CONNECTED LOAD 13,288 13,220 1 16,204 BUS A: 13,288 VA p BUS B: 13,220 VA w m CONTINUOUS LARGEST CONNECTED TOTAL N.E.C. BUS C: 16,204 VA LOAD: (CL) MOTOR LOAD: (LML) LOAD COMPUTED LOAD: LU LU w TOTAL: 42,712 VA ( 2,900 VA x 0.25) + UJ CL ( 3,600 VA x 0.25) + 42,712 VA = 43,612 VA a C� F- = Z iZ J O CALCULATED LOADS PER CHAPTER 2 OF N.E.C. AMPERES @ 120/208V,3 PHASE= 121 AMPS (AVERAGE) ' h AMPERES @ 120/208V,3 PHASE= 137 AMPS (HIGH PHASE) �O Y2 Q N o Q 1z CIL=CONTINUOUS LOAD Q Q X= ROUTE THROUGH TIMECLOCK O = LOCK ON DEVICE; F=LOCK OFF ON DEVICE hJ 5 C/) co `N O >N EXISTING ONE-NNE DIAGRAM, �r 0 O._0 cv 0 (E) 208/12OV,3(p,4W MAIN SECTION ` U (E) UTILITY CO. ( I I LO TRANSFORMER V.I.F. I ( I 0 0 f 1200A 1200A I II I SWITCH C 3P I I Project Number (E) PRIMARY7 L FEEDER P PM 16049. 1 EXISTING FEED 70 REMAIN. MINIMUM PAPA OF 2"0 C-(4)#310 CU MURPHY'S TIMECLOCK (1)#6 GND. 137A � Sheet Name L -' ELECTRICAL NEW 225A PANEL TOT REPLACE EXISTING REFERENCE ONLY RISER A N D (N) LEVITON RE480-104 EZ-MAX NOT APPROVED WITH THIS PERMIT SCHEDULES RELAY CONTROL PANEL WITH INTERNAL TIMECLOCK AND BATTERY BACKUP FOR LIGHT CONTROL Sheet Number E3 *0 PROJECT COTES KEYNOTE COTES 1 (E)SUPPLY DUCT DROP. RECONFIGURE DIFFUSER ALL APPLIANCE AND PLUMBING VENTS AND THE ENVELOPE C GENERAL MECHANICAL CONDITIONS MECHANICAL SPECIFICATIONS GENERAL NOTES LOCATIONS AS NEEDED. /� DISCHARGE OUTLET OF EXHAUST FANS SHALL BE AT NEW WALLS AND DOORS TO MATCH EXISTING AND 6 > LEAST (10) FEET IN A HORIZONTAL DIRECTION,OR MEET MINIMUM ENERGY CODE REQUIREMENTS. 1. AIR BALANCING A. DUCT SIZES SHOWN ARE SHEET METAL DIMENSIONS. NOT DUCT LINER. REFER TO T (E)RETURN DUCT DROP. RECONFIGURE RETURN �/ THREE (3) FEET ABOVE THE OUTSIDE-AIR INTAKES FOR A. CONTRACTOR SHALL PROCURE THE SERVICES OF AN INDEPENDENT NEBB OR AABC Kell MCCfgCICet"1, 1. THE GENERAL AND SPECIAL CONDITIONS OF THE ARCHITECTURAL SPECIFICATIONS CERTIFIED AIR BALANCE AND TESTING AGENCY TO BALANCE, ADJUST&TEST EQUIPMENT. MECHANICAL SPECIFICATIONS FOR DUCT INSULATION REQUIREMENTS. GRILLES AS NEEDED. HVAC UNITS. ACChIfecf SHALL BE INCLUDED AS PART OF THESE DOCUMENTS. CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING 3 COPIES OF BALANCE/TEST B. PROVIDE SINGLE WALL TURNING VANES @ ALL ELBOWS AND TEES PER SMACNA /\ Architecture•Program Management•Permitting AGENCIES REPORT TO P.S.S. PROJECT MANAGER AND LANDLORD OPERATIONS STANDARDS. <S> > NOT USED. 2. ALL MATERIALS SHALL BE NEW, UNUSED, AND THE BEST OF THEIR RESPECTIVE KINDS DIRECTOR FOR REVIEW. MIN. OUTDOOR C.F.M.AND INDOOR FAN C.F.M.SHALL BE �/ AND FREE FROM DEFECTS. PROVIDED O SHOWN ON RTU SCHEDULE. C, DO NOT PROVIDE AIR EXTRACTORS OR SPLITTER DAMPERS WHICH PROTRUDE INTO 16219 SE 12th STREET 3. THE CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE AIR DISTRIBUTION 2. DUCTWORK RECTANGULAR TRUNK DUCTS. PROVIDE ROUND SPIN-IN FITTINGS FOR ROUND 4 WALL MOUNTED THERMOSTAT. SUITE 202 A. INSTALL ALL DUCTWORK IN COMPLETE CONFORMANCE WITH RECOMMENDED BRANCH DUCTS. VANCOUVER,WA 986$3 SYSTEM WITHIN THE TENANT SPACE TO INCLUDE, BUT NOT LIMITED TO ALL TYPE'B' EXHAUST VENT. INSTALL PER DUCTWORK, HANGERS, INSULATION,VAPOR BARRIER,SUPPLY DIFFUSERS, RETURN CONSTRUCTION STANDARDS FOR RECTANGULAR AND ROUND SHEET METAL AND D. ROUND BRANCH DUCTS ARE SAME SIZE AS DIFFUSER WHICH THEY SERVE. MANUFACTURER'S RECOMMENDATION. FLEXIBLE DUCTS IN ACCORDANCE WITH SMACNA DUCT CONSTRUCTION STANDARDS O Contact: Martin D. Lakey GRILLES, FLEXIBLE CONNECTIONS, AND CONTROL INSTALLATION AS REQUIRED FOR AND ALL OTHER AUTHORITIES HAVING JURISDICTION. FLEXIBLE DUCT SHALL NOT EXCEED E. CONTRACTOR SHALL FIELD VERIFY THE EXACT SIZE, LOCATION, AND CONDITION OF LOCATE EXHAUST DUCT MIN 3'-0"FROM (360)719-1952 A COMPLETE AND WORKING SYSTEM.THE CONTRACTOR SHALL PAY ALL FEES,GIVE ALL EXISTING EQUIPMENT, PIPING, DUCTWORK, ETC.TO BE REUSED, RETAINED OR OPENINGS INTO THE BUILDING. ken.mccracken@comcast.net ALL NOTICES, FILE ALL NECESSARY DRAWINGS AND OBTAIN ALL PERMITS AND 5'-0"IN LENGTH. MINIMUM SHEET METAL THICKNESS SHALL BE 26 GA. CONNECTED TO. CERTIFICATES OF APPROVAL REQUIRED IN CONNECTION WITH ALL WORK UNDER B. ALL DUCT JOINTS LONGITUDINAL AND TRANSVERSE ARE TO BE SEALED USING 181A OR THIS CONTRACT.ALL WORK SHALL BE FURNISHED AND INSTALLED IN FULL 181 B LISTED TAPES AND MASTICS. MECHANICAL FASTENERS MUST BE USED TO FASTEN F. CONTRACTOR SHALL COMPLY WITH ALL LANDLORD'S TENANT CRITERIA. ACCORDANCE WITH ALL LOCAL LAWS,ORDINANCES, RULES AND REGULATIONS. DUCTS. COORDINATE AND SCHEDULE ALL WORK WITH LANDLORD'S FIELD REPRESENTATIVE. \� UNISEX C. STRAP HANGERS SHALL NOT BE LESS THAN I"BY 1/8"THICK ON SIX (6) FOOT CENTERS AND G. MAXIMUM FLEXIBLE DUCT LENGTH SHALL NOT EXCEED 5'-0". O \t RESTROOM 4. DRAWINGS ARE DIAGRAMMATIC ONLY, INTENDING TO SHOW GENERAL RUNS AND ATTACHED TO SIDE OF DUCT WITH SHEET METAL SCREWS. INSULATED FLEXIBLE DUCT MAY i 106 LOCATIONS OF THE WORK AND ARE NOT INTENDED TO BE RIGID IN SPECIFIC DETAIL. BE USED FOR LOW PRESSURE RUNOUTS TO INDIVIDUAL DIFFUSERS IN LENGTHS NOT TO H. CONTRACTOR SHALL PROCURE THE SERVICES OF A APPROVED NEBB OR AABC EXCEED FIVE (5) FEET FOR EACH DIFFUSER.SEAL ALL SHEET METAL SCREW PENETRATIONS. CERTIFIED AIR BALANCE&TESTING AGENCY TO BALANCE,ADJUST&TEST 3. :r,. 5. THE CONTRACTOR SHALL BE HELD TO HAVE EXAMINED THE SITE FOR HIS WORKr D. ALL RECTANGULAR AND ROUND SUPPLY DUCTWORK SHALL BE EXTERNALLY INSULATED EQUIPMENT.CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING 3 COPIES OF BEFORE HAVING SUBMITTED HIS PROPOSAL.NO ADDITIONAL COMPENSATION WILL WITH A MINIMUM THICKNESS THAT CONFORMS TO THE STANDARD OF THE LOCAL CODE BALANCE/TEST AGENCIES REPORT TO TENANT PROJECT MANAGER AND/OR / 5 BE ALLOWED FOR CONDITIONS FOUND DURING THE COURSE OF THE CONTRACT. AND SHALL IN NO CASE BE LESS THAN 1-1/2"AND SHALL HAVE A CONTINUOUS VAPOR LANDLORD'S REPRESENTATIVE AND I COPY TO THE MECHANICAL INSPECTOR AT z T I F-z _ : : :. ti ��ED ARS BARRIER JACKET W/ALL JOINTS TAPED AND SEALED. FRESH AIR DUCT SHALL HAVE 2" TIME OF MECHANICAL FINAL INSPECTION. \ , / C I �' � 6. THE CONTRACTOR SHALL VERIFY ALL MEASUREMENTS AT THE SITE AND BE KENNETH J. INTERNAL DUCT LINER FROM POINT OF OUTSIDE AIR CONNECTION TO POINT OF NOT A PART I /' RESPONSIBLE FOR THE CORRECTNESS OF THE SAME. CONNECTION AT PLENUM BOX OR MIXING BOX.ALL EXPOSED SPIRAL DUCT SHALL HAVE I. BALANCING OF AIR DEVICES SHALL BE ACCOMPLISHED BY ADJUSTING BRANCH / Nn RACKE ,..1 TAKEOFF DAMPER AT MAIN TRUNK DUCT. DAMPERS IN THE NECKS OF AIR DEVICES / \ CD-2 7. THE CONTRACTOR SHALL COORDINATE THE INSTALLATION OF HIS WORK WITH SPIRACOUSTIC INTERNAL DUCT LINER, OR TOUGHGARD ULTRA ROUND BY CERTAINTEED. SHALL BE USED FOR FINAL TRIM ONLY, AND IN PE CASE FOR GREATER THAN 10%IF / \ 50 E. PROVIDE FLEXIBLE CONNECTION BETWEEN ALL FAN POWERED EQUIPMENT AND S, WA LIGHTING PLANS, REFLECTED CEILING PLANS, LANDLORD'S SPRINKLER PLANS AND THE INDICATED VOLUME FOR THE INDIVIDUAL AIR DEVICE. / 5QALL OTHER TRADES. CONNECTING DUCTWORK. se#5599 F. ALL INSULATION, JOINING MATERIALS,SEALER, ETC..SHALL HAVE A U.L. FLAME SPREAD J. DO NOT ATTACH ANYTHING TO THE UNDERSIDE OF THE ROOF DECK. ALL LOADS ;.:. . � 8. THE INSTALLATION OF ALL EQUIPMENT AND MATERIALS REQUIRING ACCESS SHALL BE CLASSIFICATION OF NO MORE THAN 25 AND A SMOKE DEVELOPMENT RATING NOT AND BRACING MUST BE ADEQUATELY SUPPORTED FROM THE BUILDING ROOF lS1 OF MADE IN SUCH MANNER AS TO MAKE THE EQUIPMENT AND MATERIALS READILY MORE THAN 50. STRUCTURE. C 'O C f ACCESSIBLE FOR OPERATION,MAINTENANCE AND REPAIRS. 3. AIR DEVICES K. GAS PIPING SHOWN IS FOR LOW PRESSURE GAS IN THE THE BUILDING. I I A. SUPPLY DIFFUSERS: (TITUS AS STANDARD) SHALL BE FURNISHED WITH BAKED WHITE CONTRACTOR SHALL VERIFY GAS PRESSURE PRIOR TO CONSTRUCTION. 2 PSIG MAY O I I /� MANAGER Q,/,�/'7 9. STORAGE OF CONSTRUCTION EQUIPMENT AND MATERIALS SHALL BE ONLY IN ENAMEL FINISH,AND SHALL BE SELECTED FOR NECK VELOCITIES NOT EXCEEDING 800 FPM co i 1 SPACES AS DESIGNATED BY THE ARCHITECT/OWNER. AND NOISE LEVEL OF NC-35 OR LESS. BE USED IF APPROVED BY AUTHORITIES AND CLIENT. PROVIDE PRESSURE REDUCING CD-1 8"O CD-1 I I l C 103 KJW1434 B. SUPPLY DIFFUSERS SHALL BE ROUND NECK,STEEL, MODEL TMSAA,SIZED USING CRITERIA VALVES AT EACH APPLIANCE AND VENT AS RECOMMENDED BY MFG.EXTEND NEW 150 v VA 0 150 � 10. CONSTRUCTION DEBRIS AND RUBBISH GENERATED BY THE CONTRACTOR SHALL BE INDICATED ABOVE FOR LAY-IN CEILING GRID TYPE CONSTRUCTION OR DRYWALL �GAS LINE BACK TO EXISTING METER. VERIFY METER SIZE WITH UTILITY COMPANY. o o Seal CONNECT NEW GAS LINE TO EXISTING MANIFOLD. REMOVED FROM PREMISES AS OFTEN AS NECESSARY OR AS DIRECTED TO MAINTAIN CEILING AS INDICATED ON DWG.DIFFUSERS SHALL BE COMPLETE WITH ADJUSTABLE AIR C C A CLEAN AND WORKABLE AREA. PATTERNS AND VOLUME CONTROL DAMPERS. L. ALL ROOF PENETRATIONS SHALL BE APPROVED BY LANDLORD AND DONE IN C 1 l. ALL WORK AND EQUIPMENT SHALL BE FULLY GUARANTEED FOR ONE (1) YEAR FROM C. RETURNS SHALL BE 22 INCH SQUARE NECK ALUM.MODEL 50F AND/OR AS NOTED ON ACCORDANCE WITH ROOF MANUFACTURERS RECOMMENDATIONS SO AS NOT TO 100 THE DATE OF FINAL PAYMENT AND ACCEPTANCE. PLANS AND AIR DEVICE SCHEDULE. FACE VELOCITY OF RETURN REGISTERS SHALL NOT VOID THE WARRANTY. EXCEED 500 FPM. VOLUME CONTROL DAMPER NOT REQUIRED FOR RETURN INSTALLATION 12. ALL WORK, INCLUDING INSIDE OF SUPPLY AIR DUCTS,AND EQUIPMENT WITHIN THE EXCEPT WHERE NOTED. CONTRACT AREA FURNISHED AND INSTALLED UNDER THIS CONTRACT SHALL BE D. COORDINATE LOCATION OF AIR DEVICES WITH LIGHTS, SPRINKLERS,SPEAKER,SMOKE C O C CLEANED TO THE SATISFACTION OF THE OWNER BEFORE TURNING SAME OVER TO DETECTORS, ETC. PREP REA N = THE OWNER. 4. EQUIPMENT 1 QZ A. REFER TO MECHANICAL PLANS FOR SPECIFICATIONS OF HVAC EQUIPMENT. 13. CONNECT NEW WORK TO EXISTING IN A NEAT AND APPROVED MANNER. B. ALL NEW EQUIPMENT SHALL BE EQUIVALENT TO THE SPECIFIED ITEM. ANY CD-1x I 8"0 CD-1 ACCOMMODATIONS FOR ALTERNATE MANUFACTURERS SHALL BE THE RESPONSIBILITY OF GAS PIPE SIZING NOTES 150 150 14. INTERRUPTION OF HEATING, POWER AND AUXILIARY SYSTEMS WHERE AND IF THE CONTRACTOR. $ REQUIRED SHALL BE COORDINATED AND SHALL OCCUR ONLY DURING C, NEW PLATFORM EQUIPMENT SHALL HAVE VIBRATION ISOLATION MOST SUITABLE FOR THE C PREARRANGED ACCEPTABLE TIMES. APPLICATION. 1. GAS PIPE SIZING IS PER 2014 OREGON MECHANICAL PIPE SIZE: MAX CFH/MBH D. ALL EQUIPMENT SHALL BE INSTALLED ACCORDING TO MANUFACTURERS INSTRUCTIONS. SPECIALTY CODE TABLE C402.4(2). LESS THAN 2 PSI 1/2 50 15. ALL DESIGN SHALL INCORPORATE CURRENT ASHRAE METHODS. INLET PRESSURE,0.5"W.0 PRESSURE DROP. FURTHEST 3/4" 104 E. COORDINATE UNIT LOCATION WITH LANDLORD AND SITE CONDITIONS. FIXTURE FROM GAS METER IS 75 FT. (100 FT COLUMN 1" 195 O ¢ < F. GAS PIPING SHALL BE SCHEDULE 40 (ASTM-A120) BLACK STEEL WITH 300 LB. MALLEABLE 16. WHEN EXISTING DUCTWORK IS UTILIZED,SIZES SHALL BE AS SHOWN ON DWGS.AS USED.) 1-1 J4" 400 MINIMUM REQUIREMENT. IRON BANDED SCREWED OR WELD PATTERN FITTINGS AS APPLICABLE. 1-1/2" Epp w m G. ALL PIPING AND FITTINGS LOCATED OUTDOORS AND ABOVE GRADE SHALL BE CLEANED 2. PROVIDE CONNECTION TO EACH PIECE OF 2" 1,160 C C m FREE OF RUST AND PAINTED. ALL FITTINGS TO BE MADE WITH PIPE JOINT COMPOUND. EQUIPMENT WITH DIRT LEG, UNION AND GAS COCK E RT <"'„ HVAC NOTES: TEFLON TAPE NOT ALLOWED. (TYPICAL). PROVIDE GAS PIPING SUPPORTS FOR ROOF `� ON R OF `= a 5. CONTROLS MOUNTED PIPING SPACED I O'APART MAX. ''' LU 1. PROVIDE TESTING AND BALANCING FOR ALL AIR SYSTEMS. SUBMIT REPORTS TO 1 > w ARCHITECT. A. PROVIDE CONTROLS AS SPECIFIED. SPECIAL CONTROL METHODS WILL BE ADDRESSED ON ,_____ a O AN INDIVIDUAL BASIS. F- Z 2. SUBMIT SHOP DRAWINGS TO ARCHITECT FOR APPROVAL OF MAJOR MECHANICAL B. THE CONTRACTOR SHALL PROVIDE ALL 24V WIRING INCLUDING CONNECTIONS, CHECK, I w < EQUIPMENT PRIOR TO ORDERING. TEST AND START-UP. PLUMBING LOAD TABULATION - GAS CD-1 C b ¢ 150 COOLER U = m DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL WORK AND C. CONTRACTOR SHALL SUPPLY AND PROGRAM CONTROLS TO SATISFY THE REQUIREMENTS FIXTURE QTY MBH(EA) TOTAL I >Sl 104 3. SEE ALL OTHER DROF THE LOCAL ENERGY CODE. A 5°F DEADBAND SHALL BE PROGRAMMED WITH I 2 I l N r �2 CLARIFICATIONS A WORK TO BE PERFORMED. WATER HEATER 75 75 TO HERM STAT 10 20 CAPABILITY OF 550F HEATING AND 85°F COOLING SETBACK TEMPERATURES. CONTROLS _ _ _ _ __ J RG-1 < c i o a00 4. CONDENSATE FROM ROOFTOP EQUIPMENT SHALL DISCHARGE ONTO ROOF VERIFY SHALL ALSO HAVE AN ACCESSIBLE 2 HOUR OCCUPANT OVERRIDE. 550 p WITH LOCAL CODE OFFICIALS. IF OBJECTIONABLE, EXTEND CONDENSATE PIPE TO D. HVAC THERMOSTAT SHALL BE PROGRAMMED TO OPERATE AS FOLLOWS: (E)ROOFTOP UNIT 1 183 183 C C C140 APPROVED FLOOR RECEPTOR, OR EXTEND TO APPROVED EXTERIOR LOCATION. 1. OCCUPIED MODE: SUPPLY FAN TO RUN CONTINUOUSLY DURING BUSINESS HOURS TO TOTAL 258 O O U 5. SEE ARCHITECTURAL DRAWINGS FOR LOCATIONS OF DIFFUSERS, REGISTERS, GRILLES PROVIDE CONTINUOUS VENTILATION. HEATING AND COOLING TO CYCLE AS N Qf LOCATED IN THE CEILING GRID.SEE ARCHITECTURAL ROOF PLAN AND DETAILS FOR REQUIRED TO MAINTAIN ROOM SETPOINT. --- -- � LOCATION OF NEW ROOFTOP EQUIPMENT. 2. UNOCCUPIED MODE:SUPPLY FAN TO BE OFF AND OUTSIDE AIR DAMPER CLOSED. - T' SUPPLY FAN AND HEATING OR COOLING TO CYCLE AS REQUIRED TO MAINTAIN SET-UP 4 b. INSULATE LAST 5 FEET OF DUCT FROM TOILET ROOM EXHAUST DUCT WITH I"THICK AND SET-BACK TEMPERATURES. OUTSIDE AIR DAMPER TO REMAIN CLOSED DURING FIBERGLASS DUCT WRAP. PROVIDE VAPOR BARRIER. UNOCCUPIED HOURS. RG-1 - --- --- 7. DUCTWORK LAYOUT SHOWN IS RECOMMENDED. ADJUST TO COMPLY WITH LOCAL z 450 - CODE REQUIREMENTS AND AS BUILT CONDITIONS. B Q I I I CV CO� MECHANICAL SCHEDULES FRONT LINE B B B 101 N EXISTING ROOFTOP HVAC SCHEDULE CD-1 HVAC LEGEND ( , CD-1 ' --- FAN COOLING HEATING ELECTRICAL 175 175 SYMBOL DESCRIPTION MOUNTING NOMINAL MIN. ESP CAPACITY CAPACITY, CAPACITY, WEIGHT, �CV TAG / SUPPLY CFM EER VOLTAGE MCA MOCP MODEL Q DISCHARGE TONS OSA IN WG BTUH IM H OUTPUT AFUE% LBS. � � � SUPPLY AIR DIFFUSER --- A (E) RTU VERTICAL 3 1600 - - 36,000 8.95 100 79 81 208V/3P 20 30 YORK D7CGO36N07925A - 8$ �, 0.g � aSUPPLY AIR DIFFUSER - ral� Q) C3- RETURN AIR GRILLE VENTILATION SCHEDULE --- A0 BBY E ~ 0 C 0 OCCUPANT OUTSIDE AIR TOTAL REQUIRED TOTAL ACTUAL ROOM ROOM AREA S.F. OUTSIDE AIR REMARKS RETURN AIR GRILLE LOAD, CFM PER OUTSIDE AIR PER OUTSIDE AIR SUPPLY CFM RETURN/EXHAUST NAME PURPOSE PERSONS PERSON CFM PER SF ROOM PROVIDEDL0 CFM 0 LOBBY/FRONT ORDER'NG AND 721 24 7.5 0.18 96+ 130=226 250 CD-1 h' EXHAUST AIR GRILLE FOOD PICKUP D-z 175 CD_1 175 PREP/BOH SERVING/FOOD PREP 884 6 7.5 0.18 118+ 160=277 300 1600 1000 RETURN RTU A A TRANSFER AIR GRILLE MANAGER OFFICE 48 1 7.5 0.18 7+9 = 16 50 --- EF-2. MAKE UP AIR PROVIDED J v CTS PROGRAMMABLE THERMOSTAT RESTROOM BATHROOM 4$ EXHAUST 50 CFM/W.C. N/A N/A N/A - N/A 150 EXHAUST FROM RTU OSA sD DUCT SMOKE DETECTOR TOTALS 1701 519 . 600 1600 - i Project Number DAMPER - T P PM 16049. 1 16049. 1 i -MA/ FLEXIBLE DUCT DIFFUSER SCHEDULE EXHAUST FAN SCHEDULE Sheet Name MARK APPLICATION MFR./MODEL PATTERN TAG MANUFACTURER/ ACTUAL ELECTRICAL DRIVE NUMBER AREA SERVED QTY MODEL# CFM HP V/P/Hz TYPE REMARKS REFERENCE ONLY DUCTWORK SIZING CD-1 CEILING TITUS/TMS ADJ. 24x24EF-2 RESTROOM 1 PANASONIC FV-15VQ4 150 .25 FHP 115/1/60 DIRECT 1 NOT APPROVED WITH THIS PERMIT (� (�` CONSTANT PRESSURE DROP CD-2 CEILING TITUS/TMS ADJ. MECHANICAL MAXIMUM PRESSURE DROP 0.08 12x12PLAN DUCT SIZE CFM RG-1 CEILING TITUS 50F-NT EGG CRATE NOTES 6" 0-75 1. FURNISH WITH SPEED CONTROLLER, BACKDRAFT DAMPER,AND TIME DELAY SWITCH. NOTE: CONTRACTOR TO FIELD VERIFY EXISTING CONDITION 8" 75-200 OF MECHANICAL SYSTEMS IN BUILDING. CONTRACTOR TO 10" 200-375 CUT, CAP,ADJUST,AND REROUTE MECHANICAL SYSTEMS NORTH 12" 375-575 AS NECESSARY TO ACCOMMODATE TENANT Sheet Number 14" 575-900 IMPROVEMENT WORK AND MAINTAIN FULLY FUNCTIONING 16" 900-1300 MECHANICAL SYSTEMS IN ADJACENT TENANT SPACES. M 1! •O MECHANICAL PLAN 1/4"=I'-0" 4 DESIGNATED BY CONTRACTOR TO FIELD VERIFY EXISTING CONDITION OF THIS SYMBOL PLUMBING FIXTURE SCHEDULE PLUMBING SYSTEMS IN BUILDING. CONTRACTOR TO CUT, CAP, DIRECT INDIRECT ADJUST, AND REROUTE PLUMBING SYSTEMS AS NECESSARY TO FIXTURE NO. SUPPLIED BY TYPE MANUFACTURER:MODEL WASTE WASTE VENT CW HW REMARKS ACCOMMODATE TENANT IMPROVEMENT WORK AND P-1 PC WATER CLOSET KOHLER:HIGHLINE K-3979/3979-RA 31 - 71 1/2" - ADA, 1.6 GPF,WITH K-4650-A OPEN FRONT SEAT&ANGLE STOP MAINTAIN FULLY FUNCTIONING PLUMBING SYSTEM IN ADJACENT TENANT SPACES. Ken McCracken, P-3 PC LAVATORY KOHLER:PINOIR K-2035-4 71 - 1-112" 1/2" 1/2" ADA,PROVIDE K-1 5182-P FAUCET W/METAL DRAIN&BRASS P-TRAP;0.5 GPM Architect P-4 FSE HAND SINK ADVANCE TABCO:7-PS-62 71 - I-1/z, 1/2" 1/2, - Architecture-Program Management-Permitting P-5 PC MOP SINK SWANSTONE:MS-2424 BASIN CHICAGO 71 - 11-1/2, 3/4!' 3/4" INTEGRAL VACUUM BREAKER-VERIFY ACCESSORIES W/OWNER 16219 SE 12th STREET FAUCET:897-RCF S U ITE 202 P-6 PC FLOOR DRAIN ZURN:FD-2210-NT(ADJUSTABLE) 31 1-1/7, 5'o TYPE WNICKEL BRONZE TOP W/TRAP PRIMER CONNECTION AND/OR Z238 VANCOUVER, WA 98683 FUNNEL AS INDICATED P-7 PC FLOOR SINK ZURN:FD-2370-DS-H 311-1/7, 1 Z'xl Z'xg'DEEP,SINGLE PIECE W/1/2 GRATE AND DOME STRAINER Contact:Martin D. Lakey 9 P-8 PC GREASE TRAP ROCKFORD:GF-2420 31 (360 30 GPM, 156 LB.CAPACITY,W/INTERMITTENT FLOW 5'-5" �'-4"I,/ F.O.B. ken.mccracken@c719-1952 omcast.net P-9 PC FLOOR CLEANOUT ZURN:ZN-1 400(ADUSTABLE) 31 NICKEL BRONZE TOP 9 10 P-10 FSE 3-COMPARTMENT SINK ADVANCE TABCO:T9-83-60-18RL Z, 1-1/7, 3/4!' 314' VERIFY WITH EQUIPMENT INSTALLER CEX P-11 FSE PREP SINK ADVANCE TABCO:TKMG-305 314' 3/47 VERIFY WITH EQUIPMENT INSTALLER D 0 F, � � 1­_ WALL BOX BY PLUMBING CONTRACTOR F-0.8. P-12 FSE WASHER KENMORE:61532/71532 71 1-1/2" 1/2, 1/7 GUY-GRAY:W6200 HATH W/ INTEGRAL WATER HAMMER ARRESTOR Z,W W --------- WATER LOC. ESTIMATED - C Cw P-13 PC WALL CLEANOUT ZURN:Z-1441 71 W/STAINLESS STEEL WALL COVER .W cwE Cw Cw lyi.V SS -SS SS SS aw LLO) 30- Cw cw 11w 71 -6 11 12 0 2"V P ARC NOT A PART Q- P-15 PC WATER HEATER RINNAI C I 99i(GAS) 1-1/4" 1-1/4" GAS,TANKLESS 180 GPH RECOVERY @ I OOOF RISE S CW CW lyi,V 2"W SS 3�W KENNETH J. 1�2 SEWED LOC, ESTIMATED M RACKE _SS SS ck:: _SS _SS -SS -SS -SS SS SE SS SS P-18 N/A DISHWASHER AUTO-CHLOR:A5 WATER SAVER 1-1/7, 1/7' VERIFY WITH EQUIPMENT INSTALLER • AM S,WA NOTE:ALL FIXTURES MAY BE SUBSTITUTED WITH APPROVED EQUAL. CONTACT OWNER FOR APPROVAL. < 2 License#5599 PC PLUMBING CONTRACTOR. FSE FOOD SERVICE EQUIPMENT SUPPLIER. L 7 3r 2„W < SS SS or fl 3 P-1 HW HW HW-HW V PIPING MATERIALS 0 KEYNOTE NOTES V V V _ry _ V V V 3"VTR 01/18/17 EXISTING WATER SHUT-OFF VALVE. CONNECT TO I MIN. OR PER CODE) WATER LINE- 1. 5 7/�': > 17'-6 3�3" 1 /4" SANITARY SEWER AND VENT PIPING: I KJM/1434 Water Heater PLUMBING CONTRACTOR TO VERIFY SIZE AND SCOPE FOR REPLACING WATER LINE IF 00 a. SERVICE WEIGHT, CAST IRON BELL AND SPIGOT PIPE AND FITTINGS, NECESSARY. Seal NO-HUB SERVICE WEIGHT PIPE AND FITTINGS MAY BE USED ABOVE GRADE 1K, CONNECT TO 4"MIN. (OR PER CODE) SANITARY LINE-PLUMBING CONTRACTOR TO WHEN PERMITTED BY LOCAL CODE. T 12 0) VERIFY SIZE AND SCOPE FOR REPLACING SANITARY LINE IF NECESSARY. b. SCHEDULE 40,GALVANIZED STEEL PIPE AND BANDED MALLEABLE IRON > P-6 SCREW FITTINGS. CONNECT TO THE EXISTING 3"VENT THROUGH ROOF IF POSSIBLE-MAINTAIN MIN. 10' TANKLESS WATER HEATER PER c. SCHEDULE 40 AND 80 PVC OR ASB PIPING WITH DWV PATTERN FITTINGS FROM ANY AIR INTAKES. 11V2"V PLUMBING FIXTURE SCHEDULE MAY BE USED WHERE ALLOWED BY LOCAL CODE. FOAM CORE PVC 0 PLUMBING CONTRACTOR TO RUN 3/4"DRAIN LINE FROM WALK-IN COOLER,THROUGH U 3"W PIPING WILL NOT BE APPROVED. 314m Gas Connection WALL, AND INTO FLOOR DRAIN W/AIR GAP. DRAIN LINE SHALL HAVE TWO (2) INCH P-18 > -P-1 MINIMUM VERTICAL FALL PER 12 INCHES OF HORIZONTAL RUN. 2. WATER PIPING-TYPE: ---------- --------- a. 1"HARD COPPER WITH WROUGHT COPPER FITTINGS AND VALVED AT 1w H HW L GREASE TRAP. LOCATION SHOWN IS FOR REFERENCE ONLY. DRAIN LINES FROM SINK 2"W HW FIXTURES. SHALL BE INSTALLED TIGHT TO BOTTOM OF BOWL. VERIFY EXACT ROUTING IN FIELD. Al r V L---------- -------- La La > 3E b. PLUMBING CONTRACTOR MAY USE PEX PIPING FOR ALL INTERIOR 6 DOMESTIC WATER PIPING IF APPROVED BY LOCAL AUTHORITY HAVING CUT END OF INDIRECT WASTE PIPE ABOVE FLOOR SINK AT 450 ANGLE. lV2"V JURISDICTION-VERIFY IN FIELD. 2"W SS SS SS 3. PIPING INSULATION REQUIREMENTS: VENT DRYER PER LOCAL CODE AND MANUFACTURER'S SPECIFICATION. VERIFY I 7 > LANDLORD APPROVAL OF VENTING METHOD PRIOR TO INSTALLATION. a. PROVIDE MINIMUM 1.5"INSULATION WITH MAXIMUM K-FACTOR VALUE OF 0 >< GasSuPplv____ 0.27 BTU PER INCH/H SQ.FT. DEGREE F, OR AS REQUIRED PER CURRENT ly2.'Vj 3W Mot Supply Line PROVIDE HOT WATER MIXING VALVE, WATTS MODEL MMV-M I OR APPROVED EQUAL- I I­- ENERGY CODE. 3/4*Cad Water Sup2ly Line I 5 I ( 3 I I For Building FixturesO SET OUTLET TEMP AT 11 OOF. 0 T_ z 0 < < KEY 9\ CONNECT GAS PIPE TO (E) GAS PIPE. CONTRACTOR TO FIELD VERIFY SIZE AND SCOPE LLI_�____1- 1 "I >< PLUMBING LEGEND Pressure Regulator FOR REPLACING GAS PIPE IF NECESSARY. I& 314"Ball Valve LU co LU 3!4"Union cw CW CW LLJ 13 Circulating Pump CW V) 4.1 Check Valve Boiler Drain Valve TANKLESS WATER HEATER: RINNAI RL75i (OR APPROVED EQUAL) > LI) V) l'- Pressure Relief Valve Solenoid Valve ------- 3: t= :E HW HW LU PROVIDE JOSAM MODEL 88300 TRAP PRIMER AND EXTEND 1/2"PIPING TO FLOOR DRAIN. UJ POINT OF CONNECTION > LU Z < LUUJ COORDINATE ACCESS PANEL WITH G.C. LL CL (D J Z Z CW CW ew fill - _t LU < O PLUMBING KEYNOTE INSTALL FIXTURE FLUSH WITH FINISHED FLOOR-SEE FINISH SCHEDULE ON SHEET A2.1 04 LU F ca Ss N.T.S. I C.0 A SS WATER HEATER DETAIL 14 1 2"V HW 1W Cw- HW 10 0 COLD WATER LINE 7) 6 V _ V 2 W LL J JL z Jl Cw - CW V V N 0 00 �_�w SS _ SS < GENERAL NOTES HW- HW HW HW 0 -_ --(P-I 1� If I I HW HOT WATER LINE P-4 L [fill 1z 1. PLUMBING CONTRACTOR MAY USE PEX PIPING FOR ALL INTERIOR DOMESTIC 8 THREE COMPARTMENT SINK < SS SANITARY SEWER LINE WATER PIPING IF APPROVED BY LOCAL AUTHORITY HAVING JURISDICTION- IY2"VENT \V V VERIFY IN FIELD. IN WALL P-13 o2 V V /V\, 2"W V VENT LINE 2. PRIOR TO BID,THE CONTRACTOR SHALL REVIEW THE MECHANICAL, ELECTRICAL 12 P-7 2"V AND KITCHEN EQUIPMENT DRAWINGS. THE CONTRACTOR SHALL INCLUDE IN HIS CLEANOUTS V 8 1/2"- 3"W 8 P-4 21 , 2" 5'-8 1/2" 9'-2 3/4" BID ALL RELEVANT WORK IN THE ENTIRE SET OF DOCUMENTS AND REPORT ALL IN ENDS 14'-0 3/4" K CONDENSATE LINE DISCREPANCIES BETWEEN THESE DRAWINGS TO THE ENGINEER PRIOR TO 7r OF PIPE CLEANOU A SHORT TIME FRAME,THE CONTRACTOR SHALL INCLUDE THE MOST WORK AND 4" BIDDING FOR CLARIFICATION. IF DISCREPANCIES REMAIN UNRESOLVED DUE TO 2" GAS GAS LINE THE HIGHER COSTS IN THE BID. SOLUTIONS TO UNREPORTED DISCREPANCIES FLOOR 4, WILL BE DETERMINED BY THE ARCHITECT/ENGINEER,WITH NO ADDITIONAL COMPENSATION DUE TO THE CONTRACTOR. 0 WALL CLEANOUT E {U P-TRAP CUT AND PATCH FLOOR IF EXISTING FLOOR CLEANOUT LOCATE GREASE TRAP IN FLOOR V) (y) WHERE TOP CAN BE EASILY if 0 >1 REMOVED FOR CLEANING (y) to If FIXTURE AND WATER CALCULATION -to a, ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS OR cv NAME:PAPA MURPHY'S MEET LOCAL CODE REQUIREMENTS. UTILIZE HUBLESS,CAST IRON PIPE, FITTINGS if 0.g 0,� HOT AND COLD WATER WASTE AND CONNECTORS FOR SINK CONNECTIONS. CONNECT GREASE TRAP FROM =P 4__ 19, -50 LLI V) LU 0 LLaQ: LU Q� LU MID POINT OF SINK: PROVIDE P-TRAP IF GREASE TRAP IS MORE THAN 4' FROM U� D:f LL! SINK. TOTAL FIXTURE LU x 7< ?5 9 x U- UNITS U_ U- w 0 CL 0 0 0- 0 0 0 MARK DESCRIPTION z U: CW HW V) 11 P-1 WATER CLOSET(TANK) N.T.S. 5.0 5.0 5.0 31 1 4.0 4.0 L0 3-C OMP SINK DETAIL _E 0 F P-3 LAVATORY 1 2.0 1.5 1.5 2.0 1-1/2" 1 1.0 1.0 P-4 HAND SINK 2 2.0 1.5 1.5 4.0 1-1/2" 2 2.0 4.0 P-5 MOP SINK 1 3.0 2.25 2.25 1 3.0 2" 1 2.0 2.0 P-6 FLOOR DRAIN 2 31 2 2.0 2.0 P-7 FLOOR SINK 2 31 2 3.0 3.0 N F P-8 GREASE TRAP I - - 4" 1 - - IN /i FEEE� P-10 3-COMPARTMENT SINK 1 4,0 3.0 3.0 4.0 21 1 2.0 P-11 PREP SINK 1 4.0 3,0 3.0 4.0 2" 1 2.0 0 (a) Project Number P-12 WASHING MACHINE 1 4.0 3.0 3.0 4.0 2" 1 3.0 3.0 1 1 PPM 1 . 1 P-18 DISHWASHER 1 1.5 2 1.5 0'-2" 1 2 0(a) Sheet Name REFERENCE ONLY NOT APPROVED WITH THIS PERMIT TOTALS 14 19.3 16.3 27,5 14 19.0 ANY QUESTIONS OR REQUESTS FOR SUBSTITUTIONS SHOULD BE PLUMBING SUBMITTED THRU THE GENERAL CONTRACTOR. THE GENERAL TOTAL F.U. 19.0 CONTRACTOR SHOULD THEN ISSUE AN OFFICIAL REQUEST FOR PLAN & INFORMATION TO THE ARCHITECT. G.P.M. 21.5 ASSU SCHEDULES STREET STATIC PRESSURE RANGE MED 50 P.S.I. Note(a): Routed to floor sink. LOSSES: NORTH Sheet Number WATER METER 5.00 P.S.I. STATIC HEIGHT IOFT.X.43 4.30 P.S.I. P 1 *0 C^KE M S.WA n, Li PIPE LOSS(6 LBS/1 OOFT.) 3.00 P.S.I. PLUMBING PLAN 1/4"=1'-0" 41 - - - ------------- - -----------------------