Permit (43) CITY OF TIGARD FIRE PROTECTION SYSTEM PERMIT 3. COMMUNITY DEVELOPMENT Permit#: FPS2017-00059 D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/15/2017 T E(-3" f`` g Parcel: 2S 112 DA00800 Jurisdiction: Tigard Site address: 15055 SW SEQUOIA PKWY 180 Project: SMC Corporation Subdivision: PACIFIC CORPORATE CENTER Lot: 2 Project Description: Adding and relocating(6)sprinkler heads for TI. Contractor: WYATT FIRE PROTECTION INC. Owner: PACIFIC REALTY ASSOCIATES LP 9095 SW BURNHAM ATTN: N PIVEN TIGARD, OR 97223 15350 SW SEQUOIA PKWY#300 PORTLAND, OR 97224 PHONE: 503-684-2928 PHONE: 503-624-6300 FAX: 503-684-9657 FEES Description Date Amount Specifics: Permit Fee-COM 05/15/2017 $64.54 12%State Surcharge-Building 05/15/2017 $7.74 Type of Use: COM Plan Review-Fire Life Safety-COM 05/15/2017 $25.82 Class of Work: ALT Type of Const: Info Process/Archiving-Sm$0.50(up to 05/15/2017 $0.50 Occupancy Grp: Height: ft 11x17) Stories: Commercial Sprinkler System: Sprinkler Required: Yes Sprinkler Type: Wet Standpipe Required: Hazard: LT Density: .10 Design Area: 900 K Factor: 5.6 Commercial Fire Alarm System: Fire Alarm Required: Alarm Type: Pull Station Required: Smoke Detectors Req: Battery Calcs Provided: Cut Sheets Required: Total $98.60 Valuations: Required Items and Reports(Conditions) Sprinkler Valuation: $980.00 Residential Square Footage: 0 Fire Alarm Valuation: $0.00 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1. 2344. Issued By: Permittee Signature: Call 503.639.4175 by 7:00 a.m.for the next available inspec • date. r This permit card shall be kept in a conspicuous place on the Job site until completion • project. Approved plans are required on the job site at the time of each inspection. Building Permit Application Fire Protection System �' ECLiV I t SE FOR OFFICE o tA City of Tigard Received: 5' t 7 ;flip Permit No.: r 1t" , ' r Is la 13125 SW Hall Blvd.,Tigard,OR 97223Plan Review ' ' C Phone: 503.718.2439 Fax: 503.598.1960 MAXA4 ?017 Date/ B : -� Other Permit: (. ^- .."i e$ T i G A R D Inspection Line: 503.639.4175 �` (., tII•' Ready/By: H See 'age 2 for Internet: www.tigard-or.gov CITY�I I lJ"' It,:1 fied/Method: . > Ini Supplemental Information 21 Y' . 4. .,iY4TYP-:E OF',WO4 •preyA ,. •. , a." N -, `- REQUIRED DATA:`1-AND 2-FALY DWEvLLNG 0 New construction 0 Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ®Addition/alteration/replacement 0 Other: equipment,materials,labor,overhead,and the profit for the " >y , 1, :4A;, 'F" ' '''' work indicated on this application. �., CATEGO�� OB;CONSTRUCTION;:; .: • ❑ 1-and 2-family dwelling ®Commercial/industrial Valuation: $ ❑Accessory building 0 Multi-family Number of bedrooms: ❑Master builder ❑Other: Number of bathrooms: '''' r4' ' Total number of floors: . �*; y ...,�.' JOBSITE IIVFl�R11'IOAND LOCr�TION Job site address:15055 SW Sequoia Pkwq New dwelling area: square feet City/State/ZIP:Portland,OR 97224 Garage/carport area: square feet Suite/bldg./apt.no.: 180 Project name:SMC Corporation Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQU1ItEI?j?ATA OOMMLIYCIAL-USE CHE5ICLI§T„" Subdivision: I Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK '.' ; �" t 41 ,k "' work indicated on this application. Add/relocate/plug fire sprinklers for TI Valuation: $$980.00 Existing building area: square feet New building area: 0 square feet RO ER ❑ T' 1OW11TER� `=" F ;t'' Number of stories: 1 � .� � � O�TENANT Name: Type of construction: Address: Occupancy groups: City/State/ZIP: Existing: Light Phone:( ) Fax:( ) New: II AS 64 .°r' APPLICANT '41:4' •p:'-`'La.'1 ,® CONTACT-'PERSON. ,� .,4' NOTICE ,a ? a!"* ,.r .:,�"..?. Business name:Wyatt Fire Protection All • t contractors and subcontractors are required to be Contact name:Ashley Nishihara licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address:9095 SW Burnham Rd jurisdiction in which work is being performed.If the City/State/ZIP:Tigard,OR 97223 applicant is exempt from licensing,the following reasons apply: Phone:(503)684-2928 Fax::( ) I E-mail:a.nishihara@wyattfire.com Mid ,P - CONTRACTOR _ 4. „. BUILDING,PERMITFEES*, 1F, s(Please refer'to fee schedule Business name:Wyatt Fire Protection Permit fee: Address: State surcharge(12%of permit fee): City/State/ZIP: FLS plan review(40%of permit fee): Phone:( ) Fax:( ) (Due uponpplication.) CCB lie.:64077 Total permit fees. f�.,6I 0 Authorized signature: / I /1/1"41144/ Amount received: This permit application expires if a permit is not obtained Print name:Ashley i ihara ate:5/4/2017 within 180 days after it has been accepted as complete. * Fee methodology set by Tri-County Building Industry Service Board. I:\Building\Permits\FPS-PermitApp.doe Rev 01/05/2012 440.4613T(i 1/02/COM/WEB) City of Tigard: Fire Protection Permit Checklist Page 2- Supplemental Information Descr lle work to l d&is &" rr. ;sem ;,: ' a. ra r 1.) ❑ New 2.) Modification to sprinkler heads only. ❑ Addition ® 1-10 heads: No plan review required. • Alteration ❑ 11+heads: Plan review required. ❑ Repair Number of sprinkler heads: 6 • Additional description of work: Type of System,(Cpmplete A,B�,C� °gib a `applicable) `` 4 4, A) Comm rcial S rinkler .;, .r.� '� 4 . „ Wet El Dry Additional Standpipes 0 Information: Hazard Group Light Density 0.10 Design Area 900 K. Factor 5.6 Sprinkler Project Valuation: $ 980 'B.)*Type IN„I o i:Fire,Suppression'Syktei .0. „ `t,, ;4,, 3 Hood Project Valuation: $ ` * A Sff k F Kar yw a ,. ; . C) 14 44 Fire Aiarr� R,, � � s µ� ,'t �* Submittal shall Battery Calculations El Yes include: Individual Component ❑ Yes Cut Sheets Fire Alarm Project Valuation: $ D) Residenkal Sp plcter(Stand Mote bys m " c x t Square Footage: Permit Fee: 0 to 2,000 $198.75Sir 4 2,001 to 3,600 $246.45 k$ fi 3,601 to 7,200 $310.05 s4'.1b� 7,201 and greater $404.39 t vitt`i Sprinkler Project Square Footage: sq. ft. Fire'Proteclton Pe it Fee's' Project valuation subtotal (see A,B&C above): $ Permit fee based on project valuation (see fee schedule): $ Permit fee based on square footage (see D above): $ State Surcharge (112% of permit fee): $ FLS Plan Review(40% of permit fee): $ TOTAL: $ Plan review requires a completed application and three (3) sets of plans at submittal. Plan review fees are required at submittal. C:\Users\Ashley\Desktop\Permit Applications\Tigard App.doc Rev 01/05/2012 2 City of Tigard RECEIVE4mto.: ;{Jj pi 7—c q 14q 13125 SW Hall Blvd.,Tigard,OR 97223 Phone: 503.718.2439 Fax: 503.598.1960 Date Received: 5/107 T 1 c;A It I7 Inspection Line: 503.639.4175 V2017 /� Internet: www.tigard-or.gov ! 4 By: /'S ye4j✓ /A Zv'f ' tv/ rF/ FIRE SPRINKLE i �• ,� ,�•, xi ` .OR ALTERATIONS OR TENANT IMPROVEMENTS (1 to 10 SPRINKLER HEADS WITHOUT PLANS) Project Name: SMC Corporation Occupancy: Light Job Address: 15055 SW Sequoia Pkwy Type of Construction: IIIB Suite: 180 Contractor: Wyatt Fire Protection Phone: 503-684-2928 Number of Proposed or Altered Heads: 6 Type: SSP Hazard: Light Density: 0.10 I, Ashley Nishihara, Wyatt Fire Protection Oregon Construction Contractors Board No. 64077 certify the following is true and reasonably defines the scope of work for this project: a) All work is limited to drops and armovers in a light-hazard occupancy. b) Positions of sprinkler heads relative to architectural features such as soffits,beams, partitions, walls, etc. complies with current adopted edition of NFPA 13. c) The proposed work does not require hydraulic calculations. d) Only one sprinkler head will be installed from one drop (exception: up to two heads from one drop may be installed when each head is in a separate fire area). e) The area covered per sprinkler head is limited to the spacing requirements of NFPA 13. f) Tenant improvements in a new building shall be equipped with Quick Response heads (see 2002 NFPA 13, Section 8.3.3.1 for exceptions). g) The installation shall comply with the requirements of the current adopted edition of NPFA 13. h) Piping shall not be concealed until hangers and bracing are inspected. i) Final approval shall be subject to onsite tests and inspections. In addition, I understand the following is required: • Submit(3) copies of a sketch showing the area of work within the building's structure. • Building fire protection system permit. • A copy of this document with a copy of the sketch attached shall be available for all inspections. Signature: Mie AliclettovikDate: 5/4/2017 Print Name: Ashley Nishihara I:\Building\Forms\FireSprinklerAffidavit_071514.docx Page 1 of 1 City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 15055 SW SEQUOIA PKWY 180, TIGARD, OR, May 16, 2017 at 10:38:46 AM 97224 Record Type: Record ID: Commercial - Fire Protection System FPS2017-00059 Inspection Type: Inspector: 999 Sprinkler final Chip Barnett Result: PASS - NoCofO Comments: Violation Summary: Inspector Contractor