Report (40) • 1. U-factors of fenestration products(windows,doors and skylights)are determined in accordance with NFRC 100 by an accredited, - independent laboratory,and labeled and certified by the manufacturer or are determined using the commercial size category values listed in Chapter 15 of the 2009 ASHRAE Handbook of Fundamentals,Table No.4 and shall include the effects of the window frame. The temporary label afixed to the fenestration products must not be removed prior to inspection. Plans reference page/section:A0.20:A7.10 • 2. Solar heat gain coefficient(SHGC)of glazed fenestration products(windows,glazed doors and skylights)shall be determined in accordance with NFRC 200 by an accredited,independent laboratory,and labeled and certified by the manufacturer or be determined using the Solar Heat Gain Coefficients(SHGC)in Chapter 15 of the 2009 ASHRAE Handbook of Fundamentals,Table No.10.The overall values must consider type of frame material and operator for the SHGC at normal incidence. Plans reference page/section:A0.20,A7.10 Air Leakage, Insulation,and Component Certification: • 3. Sealing of the building envelope.Openings and penetrations in the building envelope are sealed with caulking materials or closed with gasketing systems compatible with the construction materials and location.Joints and seams are sealed in the same manner or taped or covered with a moisture vapor-permeable wrapping material.Sealing materials spanning joints between construction materials allow for expansion and contraction of the construction materials. Plans reference page/section:A8.50 • 4. Window and door assemblies.The air leakage of window and sliding or swinging door assemblies that are part of the building envelope are determined in accordance with AAMA/WDMA/CSA 101/I.S.2/A440,or NFRC 400 by an accredited,independent laboratory,and labeled and certified by the manufacturer. Plans reference page/section: • 5. Curtain wall,storefront glazing and commercial entrance doors.Curtain wall,storefront glazing and commercial-glazed swinging entrance doors and revolving doors are tested for air leakage in accordance with ASTM E 283. For curtain walls and storefront glazing, the maximum air leakage rate is 0.3 cubic foot per minute per square foot of fenestration area.For commercial glazed swinging entrance doors and revolving doors,the maximum air leakage rate is 1.00 cfm/ft2 of door area. Plans reference page/section:A7.10 • 6. Building thermal envelope insulation.An R-value identification mark is applied(by manufacturer)to each piece of insulation 12 inches or greater in width.Alternately,the insulation installers have provided a signed,dated and posted certification listing the type, manufacturer and R-value of insulation installed.Refer to code section for blown or sprayed insulation installation/settling depths and marker requirements. • 7. Insulation mark installation.Insulating materials are installed such that the manufacturer's R-value mark is readily observable upon inspection. • 8. Insulation product rating.The thermal resistance(R-value)of insulation has been determined in accordance with the U.S. FTC R-value rule. • 9. Installation.All material,systems and equipment are installed in accordance with the manufacturer's installation instructions and the International Building Code. • 10.Outdoor air intakes and exhaust openings.Stair and elevator shaft vents and other outdoor air intakes and exhaust openings integral to the building envelope shall be equipped with not less than a Class I motorized,leakage-rated damper with a maximum leakage rate of 4 cfm per square foot at 1.0 inch water gauge when tested in accordance with AMCA 500D.Stair and shaft vent dampers shall be capable of being automatically closed during normal building operation and interlocked to open as required by fire and smoke detection systems. Plans reference page/section: Deferred Submittal-Mechanical • 11.Loading dock weatherseals.Cargo doors and loading dock doors are equipped with weather seals to restrict infiltration when vehicles are parked in the doorway. Requirement is not applicable. Plans reference page/section: • 12.Recessed lighting. Recessed luminaires installed in the building thermal envelope are sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires are IC-rated and labeled as meeting ASTM E 283.All recessed luminaires are sealed with a gasket or caulk between the housing and interior wall or ceiling covering. Plans reference page/section: Deferred Submittal-Electrical • 13.Standing seam metal building roofs require a thermal block of R-3.5.See Table 502.2(2). Plans reference page/section:A0.20:D5 • 14.Vestibules.Doors that separate conditioned space from the exterior are protected with an enclosed vestibule,with all doors of the vestibule equipped with self-closing devices.Vestibules are designed so interior and exterior doors to not operate simultaneously. Requirement is not applicable. Plans reference page/section: Project Title: StorQuest Self-Storage Report date:08/29/16 Data filename: Page 2 of 3 IIIlk - j 15'Other'components have supporting documentation for proposed U-Factors. 11. Plans reference page/section:A7.10 Project Notes: Mechanical and Electrical systems are deferred submittals for this project. Associated calculations and COMCheck Reports will be provided with those deferred submittals. Project Title:StorQuest Self-Storage Report date:08/29/16 Data filename: Page 3 of 3 f _\ FOR OFFICE USE ONLY—SITE ADDRESS: This form is recognized by most building departments in the Tri-County area for transmitting information. Please complete this form when submitting information for plan review responses and revisions. This form and the information it provides helps the review process and response to your project. City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT :74 Transmi ttal Letter T I G A R rD 13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.718.2439 • www.tigard-or.gov TO: DAN NELSON DATE RECEIVED;, DEPT: BUILDING DIVISION 1B 2 Y FROM: Dirk McCulloch r 4 ' COMPANY: Magellan Architects PHONE: 425-885-4300 By:4 j RE: 12800 SW Pacific Hwy, Tigard 97223 BUP2016-00261 (Site Address) (Permit Number) StorQuest Self Storage Tigard (Project name or subdivision name and lot number) / /// aglyi /1' ATTACHED ARE THE FOLLOWI ITEMS: .' Copies: :;Description: Copies:: Description: Additional set(s) of pla's. 2 Revisions: See attached letter Cross section(s) and a-tail Wall bracing and/or lateral analysis. Floor/roof framing. Basement and retaining walls. Beam calculation 2 Engineer's calculations. Other(explain): REMARKS: Please see attac -d letter for description of proposed revisions; accompanying engineering calculatinos are in support of 'e proposed revisions. FO O. CE USE ONLY Routed to Permit Technician. ate: - re (7 Initials Fees Due: ❑ Yes ! o Fee Description: Amount ue: Special Instructions: Reprint Permit (per PE): n Yes n No n Done Applicant Notified: Date: Initials: I:\Building\Forms\TransmittalLetter-Revisions.doc 05/25/2012