Loading...
Plans (92) yt 57)-&iCe-000 E7 RECEIVEDc S-3 U 3 S�v verc�s«45 011). MitMAR 8 2016 CITY OF TIGARD M iTe k BUILDING DIVISION MiTek USA, Inc. 7777 Greenback Lane Suite 109 Citrus Heights,CA,95610 Telephone 916/676-1900 Re: PL14-403_UPPER Fax 916/676-1909 POLYGON The truss drawing(s)referenced below have been prepared by MiTek Industries,Inc.under my direct supervision based on the parameters provided by Pacific Lumber & Truss Co.. Pages or sheets covered by this seal:R43360047 thru R43360076 My license renewal date for the state of Oregon is June 30,2015. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. � R a. PRO ✓ c. GlNF fi C: 8 • 2PE SNA 7 �� OREGON qo t1r "PO 6) $ER1� A. HE EXPIRES:06/30/2015 December 5,2014 Hemandez,Marcos The seal on these drawings indicate acceptance of professional engineering responsibility solely for the truss components shown. The suitability and use of this component for any particular building is the responsibility of the building designer,per ANSUTPI 1. is Job Truss Truss Type Qty Ply POLYGON R43360047 PL14-403_UPPER F01 FLOOR GIRDER 1 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Fri Dec 05 09:52:58 2014 Page 1 ID:L2O9JJu6omRCBuYOhHV69uyFHbu-QufpMT16arSsJ2n33KuAhlo&mlUbPT5HTux_y5yCOw3 3x6 II 1-3-4 3xI6 11 1-6-0 13x6 Il 1 6 2 7 3 Scale=1:13.1 _ 0o ot ,:4% 5 4 6x6= 6x6= I 3-3.4 I 3-3-4 LOADING(psf) SPACING- 1-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.41 Vert(LL) 0.00 5 """" 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.06 Vert(TL) -0.00 4-5 >999 360 BCLL 0.0 Rep Stress Incr NO WB 0.23 Horz(TL) 0.00 4 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:31 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 3-3-4 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 5=1026/Mechanical,4=1154/Mechanical FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 1-5=-278/0,3-4=-511/0 BOT CHORD 4-5=0/590 WEBS 2-4=-868/0,2-5=-947/0 NOTES- 1)Refer to girder(s)for truss to truss connections. 2)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)1007 lb down at 0-11-3,and 1007 lb down at 2-6-6 on top chord. The design/selection of such connection device(s)is the responsibility of others. 5)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). LOAD CASE(S) Standard 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 Uniform Loads(pit) ConcentVert 6rated =1d007(F)7=-1007(F) 7CO�' 4 GIOF-zNE cS'l%, '3 ct 8 e 2PE f ("` -7 to it N �A OREGO 41, QAC/ Or)�' $ER1 Ca 8 A. HERkP EXPIRES:06/30/2015 December 5,2014 i _ e A WtFINIMi-tfertrdesign r lrantrGts xxd READ?,CIES CNINISAND 1fCf1P.ED Kra REF€RENa PAGE NII 7473 re c 1125/2014ft1F#.4£f/5€ Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component. . Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown MiTek* �T '` is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the �IQK•� erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding 1 R fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TPI1 Quailly Cdfeda,DSB-89 and SCSI Building Component 7777 Greenback Lane,Suite 109 Safely Information available from Truss Plate Institute.781 N.Lee Street,Suite 312.Alexandria.VA 22314. Citrus Heights,CA,95610 Ef Southern Mast f&P)lumber is cifIad,the Nesters values art tf1ME effective €8?1/2OLS bv ALSG Job Truss Truss Type Qty Ply POLYGON R43360048 PL14403_UPPER F02 FLOOR GIRDER 1 2 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Fri Dec 05 09:52:59 2014 Pagel ID:L2O9JJu6ortsRCBuYOhHV69uyFHbu-u4DBap1 kL8ajxCMGd1 PPEyLE?9N8rOQYhXUXyCOw2 1 1-2-0 1 1-9-0 Scale=1:26.3 2x4 II 5x10 = 1.5x4 II 3x4= 1.5x4 I I 3x4= 1.5x4 II 5x10= 3x4 II 1 2 15 3 16 17 18 4 19 20 5 21 22 6 23 7 24 25 8 26 9 0 H II 11 1 ° 1/ J '', 2-- o 0 d N �. e I o I o e Nf 13 12 11 4x8 MT2OHS= 6x10= 3x8= 8x10= 4x8 MT2OHS= I 14-10-8 I 1410-8 LOADING(psf) SPACING- 1-0-0 CSI. DEFL. in (loc) I/deft Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.76 Vert(LL) -0.18 12 >977 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.75 Vert(TL) -0.28 12 >620 360 MT2OHS 165/146 BCLL 0.0 Rep Stress Incr NO WB 0.54 Horz(TL) 0.09 10 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:147 lb FT=0% LUMBER- BRACING- TOP CHORD 2x4 DF 2400F 2.0E TOP CHORD Structural wood sheathing directly applied or 3-5-15 oc purlins, except BOT CHORD 2x4 DF 2400F 2.0E end verticals. WEBS 2x4 DF No.1&Btr BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (Ib/size) 10=6417/0-5-8 (min.0-3-3),14=5901/0-5-8 (min.0-2-15) FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 9-10=-1219/0,2-15=-9563/0,315=-9563/0,3-16=-9563/0,16-17=-9563/0,17-18=-9563/0,4-18=-9563/0, 4-19=-13782/0,19-20=-13782/0,5-20=-13782/0,5-21=-13782/0,21-22=-13782/0,6-22=-13782/0,6-23=-10085/0, 7-23=-10085/0,7-24=10085/0,24-25=-10085/0,8-25=-10085/0 BOT CHORD 13-14=0/4476,12-13=0/12626,11-12=0/12830,10-11=0/5836 WEBS 8-10=-7656/0,8-11=0/5720,7-11=-1402/0,6-11=-3696/0,6-12=0/1281,5-12=-1875/0,4-1200/1556,4-13=-4123/0, 3-13=-1888/0,2-13=0/6849,2-14=-7081/0 NOTES- 1)2-ply truss to be connected together with 10d(0.131"x3")nails as follows: Top chords connected as follows:2x4-1 row at 0-2-0 oc. Bottom chords connected as follows:2x4-1 row at 0-9-0 oc. Webs connected as follows:2x4-1 row at 0-9-0 oc. 2)All loads are considered equally applied to all plies,except if noted as front(F)or back(B)face in the LOAD CASE(S)section.Ply to ply connections have been provided to distribute only loads noted as(F)or(B),unless otherwise indicated. 3)All plates are MT20 plates unless otherwise indicated. 4)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-lOd(0.131"X 3")nails. Strongbacks to � 0) PR QE be attached to walls at their outer ends or restrained by other means. tSkr 6)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)114 lb down at 1-3-1,1033 lb down �C3 NGINE -� !Q at 1-7-12,114 lb down at 2-10-4,1033 lb down at 3-2-15,637 lb down at 311-4,114 lb down at 4-4-15,1007 lb down at 4-10-2,114 2 lb down at 5-11-2,1007 lb down at 6-5-5,114 lb down at 7-0-13,637 lb down at 7-6-4,1027 lb down at 8-0-8,114 lb down at 9-1-8, kr^ 1' 1027 lb down at 9-7-11,114 lb down at 10-8-11,1027 lb down at 11-2-14,114 lb down at 12-3-14,1027 lb down at 12-10-1,and 114 Q 87022PE t'" lb down at 13-11-1,and 1027 lb down at 14-8-12 on top chord. The design/selection of such connection device(s)is the responsibility of others. LOAD CASE(S) Standard SCA O Ni 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 OREG N ti kr `Q Uniform Loads(plf) 0BA �'� Vert:10-14=-5,1-9=-50 Concentrated Loads(lb) G A He.04 Vert:9=-1027(F)8=-1027(F)7=-114(B)6=-114(B)5=-114(B)3=-1033(F)2=-1147(F=-1033,B=-114)15=-114(8)16=-637(F) 17=-114(B)18=-1007(F)19=-114(B)20=-1007(F)21=-637(F)22=-1027(F)23=-1027(F)24=-1027(F)25=-114(B)26=-114(B) EXPIRES:06/30/2015 December 5,2014 . t AWAINN/MS-Vi/fydes)7a,:arametrrsartdREAP WITS O`THIS AM DOZED ICIEK REFERENCE PAMg7473rcxi,/J5/ _aRE.:(f Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component. Applllcabirity of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the MiTek. Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding fabrication,quality control,storage,delvery,erection and bracing,consult ANSI/TPIt Quality Criteria,DSB-89 and SCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria.VA 22314. Citrus Heights,CA,95610 if Southern.Stir.(&P)toe ben is specified,.the Jexigvsvatues aka those a astrue 0614t3f201.3 by MSC Job Truss Truss Type Qty Ply POLYGON R43360049 PL14-403_UPPER F03 FLOOR GIRDER 2 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Fri Dec 05 09:52:59 2014 Paget ID:L2O9JJu6omRCBuYOhHV69uyFHbu-u4DBap1kL8ajxCMGd1PPEyLOp9ga8ztQiYhXUXyC0 2 I 1-6-4 I 1.5x3 II 1 3x4= 2 Scale=1:13.2 0 • o N r 4 3 1.5x3 II 3x4= I 1-9-4 1-9-4 LOADING(psf) SPACING- 1-0-0 CSI. DEFL. in (loc) I/dell Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.07 Vert(LL) 0.00 4 "" 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.01 Vert(TL) -0.00 4 >999 360 BCLL 0.0 Rep Stress Incr NO WB 0.00 Horz(TL) 0.00 3 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:13 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 1-9-4 oc purlins, except BOT CHORD 2x4 OF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 4=45/Mechanical,3=45/Mechanical FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)Refer to girder(s)for truss to truss connections. 2)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard 'atD PROre ' tv co� , ,. 5��* 4 87022PE r- 7 5, �,.0T QREG N cy'q(U �0 8'ER 1� �� S A. Ntic\.•41)* EXPIRES:06/30/2015 December 5,2014 4 A WARNL'43.ttet tr detfn pram tern ar:d READ IC TSS ai THIS AM MUM MITEf REFERENCE PAGE HIT 7 413 MB 1,;75/2#84 BEMUSE is Design valid for use only with MTek connectors.This design is based only upon parameters shown,and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the MiTek` erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding R fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TPD QuaBly Criter a.DSB-89 and SCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute.781 N.Lee Street,Suite 312.Alexandria.VA 22314. Citrus Heights,CA,95810 tfSeruSharri Fine(SP ttar ttax is specified,the ledge vetums are these 413081t111e 06/i}1f 13 try ALSC Job Truss Truss Type Qty Ply POLYGON R43360050 PL14-403_UPPER F04 FLOOR GIRDER 2 1 Job Reference(optional) Pacific Lumber 8 Truss Co., Lake Oswego,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Fri Dec 05 09:53:00 2014 Page 1 ID:L2O9JJu6omRCBuYOhHV69uyFHbu-NHman92M6Sja71 xSAkwemAtXdZ33tIEZwBQ4OzyCOw1 11-0-8 II 2-0.0 1 Scale=1:37.9 3x4= 5x6= 1.5x3 I I 4x4= 1.5x3 I I 3x4= 1.5x3 I I 3x4= 1.5x3 I I 3x6 FP= 1.5x3 I I 4x5= 3x4 I I 1 2 3 4 5 6 22 7 23 8 9 10 11 12 13 m o ee i \-/A.\ - /i 2/ X-/.." 141444\ - /4'4IN 0 d m' n 21 20 19 18 17 16 15 14 3x4 I I 5x5= 4x6= 3x6 FP= 3x5= 3x5= 4x6= 3x6= 1.5x3 SP= I 22-2-0 22-2-0 I Plate Offsets(X.Y)— j1Edge 0-1-81 121'Edge.0-1-81 LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (lac) 1/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.19 Vert(LL) -0.16 16-17 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.50 Vert(TL) -0.26 16-17 >999 360 BCLL 0.0 Rep Stress Incr NO WB 0.57 Horz(TL) 0.06 14 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:120 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (Ib/size) 21=969/0-5-8 (min.0-1-8),14=969/0-5-8 (min.0-1-8) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-21=-970/0,1-2=-615/0,2-3=-615/0,3-4=-2111/0,4-5=-2111/0,5-6=-2806/0, 6-22=-2806/0,7-22=-2806/0,7-23=-2693/0,8-23=-2693/0,8-9=-2693/0,9-10=-1772/0, 10-11=-1772/0,11-12=-1772/0 BOT CHORD 19-20=0/1456,18-19=0/2550,17-18=0/2550,16-17=0/2844,15-16=0/2324,14-15=0/1005 WEBS 12-14=-1341/0,12-15=0/1035,9-15=-747/0,9-16=0/498,5-17=0/346,5-19=-593/0, 3-19=0/885,3-20=-1137/0,1-20=0/1121 NOTES- 1)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 2)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 3)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)5 lb down at 10-6-12,and 5 lb down at 12-11-4 on top chord. The design/selection of such connection device(s)is the responsibility of others. 4)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). LOAD CASE(S) Standard 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 ‘,1/4'0 PR°Fe Uniform Loads(plf) )N j Vert:14-21=-8,1-13=-80 ?`� T`, ,9 Qj Concentrated Loads(Ib) 4L Vert:22=-5(B)23=-5(B) � 870 2PE. r" N -7 '��,, ORES Nti� 4/ dor48ERA 4) A. HER EXPIRES:0613012015 December 5,2014 4 B A W4!INI?SO-tte:fp destms parameters mad REAS W,IES ON mrs AND TEEXUSEO efITEK REFE.RENCE;AGE M117473 set 1,129/201W 8ff011E(SE Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component. �m Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the MiTek" erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding i VBI Iek" fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane,Suite 109 Solely Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Carus Heights,CA,95610 IfSauthe eene(SR)lumber is specified,the design values are:theee effective 136/&83/21123 by MSC Job Truss Truss Type Qty Ply POLYGON R43360051 PL14-403_UPPER F06 GABLE 1 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Fri Dec 05 09:53:02 2014 Page 1 I D:L2O9JJu6omRCBuYOhHV69uyFHbu-JfuKC r4de3zlof5r19z6razwN NsH LK5sOVvBSsyCOw? 0-ftr8 Scale=1:38.6 3x6 FP= 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 ■ g 9 9 9 2 9 a 9 9 o 9 ■ 0 9 9 9 9 e 42 I o i 7 7' '7 - - - _ -40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 3x6 FP= 1 1-4-0 1 2-8-0 1 4-0-0 I 5-4-0 I 6-8-0 1 8-0-0 I 9-4-0 I 10-8-0 1 12-0-0 1 13-4-0 1 14-8-0 I 16-0-0 1 17-4-0 1 18-8-0 1 20-0-0 I 21-4-0 1 22-8-0 3-5-1?� 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 b-9-12 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.05 Vert(LL) n/a - n/a 999 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.01 Vert(TL) n/a - n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.03 Horz(TL) 0.00 21 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:110 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 DF Stud/Std(flat) REACTIONS. All bearings 23-5-12. (Ib)- Max Gray All reactions 250 lb or less at joint(s)40,21,39,38,37,36,34,33,32,31,30,29,28,27,26, 25,24,23,22 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)All plates are 1.5x3 MT20 unless otherwise indicated. 2)Gable requires continuous bottom chord bearing. 3)Truss to be fully sheathed from one face or securely braced against lateral movement(Le.diagonal web). 4)Gable studs spaced at 1-4-0 oc. 5)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 6)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 7)CAUTION,Do not erect truss backwards. LOAD CASE(S) Standard ,a ,o PRQFE• �cNG(NE€9 of 87022PE r'" w EXPIRES:06/30/2015 December 5,2014 t f ®WA.>1NIM3-Vc„')f dcaiyn pa;ausrmrs and REAIl hG7£S GM THIS A70 Iii uno AfI7£XREFERENCE PAGE 94717 473 rex.1/75/29148 lWt£t1 Design valid for use only with MiTek connectors.This design is based onlyupon parameters shown.and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer-not Muss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the MiTek erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding IY� fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TPII Quality Criteria,DSB-89 and SCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available horn Truss Plate Institute.781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 14S sustaerePinh t1SPItunstner isswiftest the design■*Goes are those etfestire 06/03/2013 byAt.SC Job Truss Truss Type Qty Ply POLYGON R43360052 PL14-403_UPPER F07 GABLE 1 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Fri Dec 05 09:53:03 2014 Page 1 ID:L2O9JJu6omRCBuYOhHV69uyFHbu-nsSIQB4FON59Qpg1 stULOoV4YmCP4nLOd9fldlyCOw_ P Scale=1:18.4 1 2 3 4 5 6 7 8 9 10 21 J 123 O 0 0 d N O 0 20 ^o O 0 0 0 0 22 19 18 17 16 15 14 13 12 11 3x4= 1-4-0 2-8-0 1 4-0-0 5-4-0 6-8-0 8-0-0 9-4-0 1 10-8-0 111-1-81 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 0-58 LOADING(pst) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.09 Vert(LL) n/a - n/a 999 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.01 Vert(TL) n/a - n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.03 Horz(TL) 0.00 11 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:57 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 DF Stud/Std(flat) REACTIONS. All bearings 11-1-8. (Ib)- Max Gray All reactions 250 lb or less at joint(s)19,11,18,17,16,15,14,13,12 FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)All plates are 1.5x3 MT20 unless otherwise indicated. 2)Gable requires continuous bottom chord bearing. 3)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web). 4)Gable studs spaced at 1-4-0 oc. 5)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/Mil. 6)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard �.,,�o PROF , w\ <‘..t4 GINE '',9 �0_ 'r $70 2PE - m'0,,, OREGO -,1,O4A "POs'f8ER 41 v.� A. NES ' EXPIRES:06/30/2015 December 5,2014 4 f ps :da-4cr;fydesiggn parametersandREAD WIES 01THIS AND 1M21/OEEMIT€X:lEFEf(EME ME MEl.7473rex 1,129/20/48LF 3f>OE Design valid for use only with MTek connectors.This design is based only upon parameters shown,and is for an individual building component. 'Y Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the MiTek* erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding IMl 1 R fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/7P11 Quality Criteria,DSB-89 and BCSI Bu8ding Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute,781 N.Lee Street.Suite 312,Alexandria.VA 22314. Citrus Heights,CA,95610 1fSouthern Pine!SP)tum,,erts the ified,thd sign wig.are ti•esadE effective W05/2MM/2M 3 bliAILSC • Job Truss Truss Type Qty Ply POLYGON R43360053 1.1_14-403_UPPER FOB GABLE 1 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Fri Dec 05 09:53:03 2014 Page 1 ID:L2O9JJu6omRCBuYOhHV69uyFHbu-nsSiQB4FON59Qpg1 stULOoV55mCX4nLOd9fidlyCOw_ i4 1 2 3 4 Scale=1:13.0 J 10 O N — — — 9 .. .. . ... ... .... .. ... 8 7 6 5 1-4-0 2-B-0 38-8 1-4-0 1-4-0 1-0-8 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.05 Vert(LL) n/a - n/a 999 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.01 Vert(TL) n/a - n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.03 Horz(TL) 0.00 5 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:21 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 3-8-8 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 DF Stud/Std(flat) REACTIONS. All bearings 3-8-8. (Ib)- Max Gray All reactions 250 lb or less at joint(s)8,5,7,6 FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)All plates are 1.5x3 MT20 unless otherwise indicated. 2)Gable requires continuous bottom chord bearing. 3)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web). 4)Gable studs spaced at 1-4-0 oc. 5)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 6)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 7)CAUTION,Do not erect truss backwards. LOAD CASE(S) Standard PRoits G N do, Q .$ f 2PE / < QREGO <i BER �� C�S A. HER EXPIRES:06/30/2015 December 5,2014 i _ f ®W4AW -Verify-dcaiye%auraetorsuralREAD l'DITS ONMIS MC//MOEDNTTESREFERENCE TMEMTi7473m 1,/79/291$DEMME Design valid for use only with Mitek connectors.This design is based only upon parameters shown,and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the a '���* erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TPI1 QuaIBy Crlteda,DSB-B9 and BCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312.Alexandria,VA 22314. Citrus Heights,CA,95610 ttSersttae'rerPine tiSin lunsbakr is specified,the designuatuzs am thous efiective 0.6101f2O13 tsq•MSC Job Truss Truss Type Qty Ply POLYGON R43360054 PL14-403_UPPER F09 GABLE 1 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Fri Dec 05 09:53:04 2014 Page 1 ID:L2O9JJu6omRCBuYOhHV69uyFHbu-F204dW5t9hD?1zFDPa?ax?2F1AYipDa9rpO181yCOvz 0-flt-8 Scale=1:39.8 3x6 FP= 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 ■ = 0 7 a c e e ? o ° m g o o e 1 a 42 I o a a.","A ny nn ° Al(' r iv�nnn nnw?n �l 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 28 25 24 23 22 21 3x6 FP= i 1-401 2-8-0 I 4-0-0 i 5-4 4 4 0 i 6-8-0 1 8-0.0 i 90 I 10-8-0 i 12-0-0 i 130 I 14-8-0 I 16-0-0 i 17-4-0 i 18-8-0 I 20-0.0 i 21-4-0 I 22-8-0 i 24-3-0 1-4-0 1-4-0 1-4-0 140 1-4-0 140 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-7-0 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Lldefl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.10 Vert(LL) n/a - n/a 999 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.01 Vert(TL) n/a - n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.03 Horz(TL) 0.00 21 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:112 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 DF Stud/Std(flat) REACTIONS. All bearings 24-3-0. (Ib)- Max Gray All reactions 250 lb or less at joint(s)40,21,39,38,37,36,34,33,32,31,30,29,28,27,26, 25,24,23,22 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)All plates are 1.5x3 MT20 unless otherwise indicated. 2)Gable requires continuous bottom chord bearing. 3)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web). 4)Gable studs spaced at 1-4-0 oc. 5)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/Mil. 6)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 7)CAUTION,Do not erect truss backwards. LOAD CASE(S) Standard ��,,>cp QF�ss 'PR� to 2 , • 2PE (r 7 -0),OREGO cit 4(i Is0 ''OBER \0 A. Heiik NP EXPIRES:06/30/2015 December 5,2014 B AWHA .Voritydesignparametersand PO7ESONTHIS AND It1QIUOED MITEKSEEEREN7EPAGE MU.7473 mmc1/29/2L}i4MR34EEt15E a...« Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the ■� erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding MITA' . fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TPIt Qualify Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 if Smuth.erss Pine(5P}kuntsea is spec r111e4 The dawn-values are Phase effacen a oG/ff1/2£tiby .3 AL6C e Job Truss Truss Type Qty Ply POLYGON R43360055 PL14-403_UPPER F10 GABLE 1 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Fri Dec 05 09:53:05 2014 Page 1 I D:L209JJu6omRCBuYOhH V69uyFHbu-jEaTgs6Vw_Lsf7gPzl WpTDbQZat?YgtJ4T8rgByCOvy apa Scale=1:28.3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 e o e e e _ o O o e _ _ e • 31 : 0 d M 29 . 0 0 0 o o e o o o o o e • XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX. 28 27 26 25 24 23 22 21 20 19 18 17 16 15 1-4-0 2-8-0 4-0-0 54-0 6-8-0 8-0-0 9-4-0 10-8-0 12-0-0 13-4-0 14-8-0 16-0-0 17-3-0 l 1-4-0 l 1-4-0 1 1-4-0 l 1-4-0 l 1-4-0 l 1-4-0 l 1-4-0 l 1-4-0 l II ' l 1-4-0 1-4-0 1-4-0 1-4-0 1-3-0 LOADING(psi) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Lid PLATES GRIP TOLL 40.0 Plates Increase 1.00 TC 0.05 Vert(LL) n/a - n/a 999 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.01 Vert(TL) n/a - n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.03 Horz(TL) 0.00 15 n/a n/a BCDL 5.0 Code IBC2012/rP12007 (Matrix) Weight:81 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 DF Stud/Std(flat) REACTIONS. All bearings 17-3-0. (Ib)- Max Gray All reactions 250 lb or less at joint(s)28,15,27,26,25,24,23,22,21,20,19,18,17,16 FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)All plates are 1.5x3 MT20 unless otherwise indicated. 2)Gable requires continuous bottom chord bearing. 3)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web). 4)Gable studs spaced at 1-4-0 oc. 5)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 6)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 7)CAUTION,Do not erect truss backwards. LOAD CASE(S) Standard �ycO PR OFe6, 870 2PE f 7 A},OREGON rt-4- ' 0'0 fi48ER 1� A. SC;'- EXPIRES:06/30/2015 December 5,2014 e _ A 4RNTMI-Verrdetignpass ersemitREATIliOTESON1HTSAM)1M3.l ED Ml EK REFERENCE PAGE MTTL7473ret 1,29/26tal�tTSE Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component. M• Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the MiTek.erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding �BYM�B i fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TPI1 Quality Criteria,DSB-89 and SCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 If Southern Pine('SP)tamsber is Spetifirtik,the design asthma aro those effective 06/GS12013 by AMSC • Job Truss Truss Type Qty Ply POLYGON R43360056 PL14-403_UPPER F11 GABLE 1 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Fri Dec 05 09:53:06 2014 Page 1 ID:L2O9JJu6omRCBuYOhI-V69uyFHbu-BQ8r2C77hIT)HGPcX?120Q7bO_DFH76SJ7tPDdyCOvx Scale=1:18.4 1 2 3 4 5 6 7 8 9 20 d 0 18 17 16 15 14 13 12 11 10 1-4.0 2-8-0 4-0-0 I 5-4-0 I 6-8-0 I 8-0-0 9-4-0 I9-9-12 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 1-4-0 0-5-12 LOADING(psi) SPACING- 2-0.0 CSI. DEFL. in (lac) 1/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.05 Vert(LL) n/a - n/a 999 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.01 Vert(TL) n/a - n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.03 Horz(TL) 0.00 10 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:49 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 DF Stud/Std(flat) REACTIONS. All bearings 9-9-12. (Ib)- Max Gray All reactions 250 lb or less at joint(s)18,10,17,16,15,14,13,12,11 FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)All plates are 1.5x3 MT20 unless otherwise indicated. 2)Gable requires continuous bottom chord bearing. 3)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web). 4)Gable studs spaced at 1-4-0 oc. 5)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 6)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 7)CAUTION,Do not erect truss backwards. LOAD CASE(S) Standard ‘NtO PR 0 - Ca k,GIN4- 70 870 2PE /9 11 Al y SAT OREGON tid�4 0" �418ER 1\ 0S k H ERS EXPIRES:06/30/2015 December 5,2014 0 e ®M4!WI -Verity design parameters a d READ N2IEES CU THIS AND MIMED 14fIEK R€FER€7CE PAW MMMT 7473 ret J/25/2S?4 !/SE Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component. Applicability of design parameters and proper incorporation of component i responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibility of the ■�i.t�.� erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding �}(t fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 if Southern Fine(SP)turnber is specified,tie designvalues are Thole.effective 06/831/201.4 byA SC Job Truss Truss Type Qty Ply POLYGON R43360057 PL14-403_UPPER F12 Floor 8 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Fri Dec 05 09:53:07 2014 Page 1 ID:L2O9JJu6omRCBuYOhH V69uyFHbu-fdiDFY7lScbauQzoSYHYegk_OVjOTSbXndyl3yCOvw 0-1-8 H I 1-6-0 H I 2-6-0 I Scale=1:30.0 4x4= 1.5x3= 1.5x3= 1.5x3 I I 3x4= 1.5x3 II 3x4= 1.5x3 II 3x4= 1.5x3 II 1 2 3 4 5 6 7 8 7 -N.o ° 15 Ne R 7 - . 7 -N. . 0 14e > 4. *M 12 11 10 9 1.5x3 II 4x5= 3x5= 3x5= 3x4= I 17-3-0 I 17-3-0 Plate Offsets(X.Y)— VI:Edae.0-1-8] LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/deft Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.19 Vert(LL) -0.07 10-11 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.31 Vert(TL) -0.11 10-11 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.47 Horz(TL) 0.03 9 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:88 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (Ib/size) 13=748/0-5-4 (min.0-1-8),9=748/Mechanical FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 13-14=-749/0,14-15=-749/0,1-15=-749/0,1-2=-611/0,2-3=-611/0,3-4=-1651/0,4-5=-1651/0,5-6=-1457/0, 6-7=-1457/0 BOT CHORD 11-12=0/1275,10-11=0/1696,9-10=0/887 WEBS 7-9=-1100/0,7-10=0/706,5-10=-296/0,3-11=0/466,3-12=-822/0,1-12=0/933 NOTES- 1)Refer to girder(s)for truss to truss connections. 2)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4)CAUTION,Do not erect truss backwards. LOAD CASE(S) Standard 4,. .4 .5 PRQ/ s,9 , F.NGIt44 R "0 cc 8 e 2PE. c 40( / eY tv 9 �A�OREGO: ti,.40 Ch SER`9 A. HERS EXPIRES:06/30/2015 December 5,2014 A mom-4EsitrdesiyrspsrammfersaasdREAD GOfESONTHIS: MUM htfTEKREFERENCE PAGE ffaa 7473 mc 1/7S/294d& A£UUSE mil... Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stabilrfy during construction is the responsibillity of the MiTek.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/1PI1 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane,Suite 109 ISSo rithwrn (SP)v available from Truss redlat Institute,781 N.Lee Street,d Suite$ ou 06/01/sari;by 22314. Citrus Heights,CA,95610 Job Truss Truss Type Qty Ply POLYGON R43360058 PL14-403_UPPER F13 Floor 11 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Fri Dec 05 09:53:08 2014 Page 1 ID:L209JJu6omRCBuYOhHV69uyFHbu-8pFbTu80DvjRWaY_eQ3W5rDtZnn9lsPImRMVHWyCOvv p-1O-81 2-8-0 ) 0-j8 Scale=1:41.2 4x6 = 3x4= 3x4= 3x4= 3x6 FP= 4x5= 1 2 3 4 5 6 7 8 9 10 11 12 a 21 I a v e e e e 20 19 18 17 16 15 14 13 3x4= 4x8= 3x6 FP= 3x5= 3x5= 4x6 = 3x4= 243-0 24-3-0 LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) 1/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.26 Vert(LL) -0.23 15-16 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.55 Vert(TL) -0.38 15-16 >760 360 BCLL 0.0 Rep Stress Ina YES WB 0.75 Horz(TL) 0.08 13 n/a n/a BCDL 5.0 Code 1BC2012/TP12007 (Matrix) Weight:121 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 13=1055/0-5-4 (min.0-1-8),19=1055/Mechanical FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-1712/0,3-4=-1712/0,4-5=-3137/0,5-6=-3137/0,6-7=-3331/0,7-8=-3331/0,8-9=-2298/0,9-10=-2298/0, 10-11=-2298/0 BOT CHORD 18-19=0/522,17-18=0/2564,16-17=0/2564,15-16=0/3375,14-15=0/2956,13-14=0/1307 WEBS 11-13=-1620/0,11-14=0/1227,8-14=-816/0,8-15=0/464,6-16=-294/0,4-16=01710,4-18=-1056/0,2-18=0/1474, 2-19=-1167/0 NOTES- 1)All plates are 1.5x3 MT20 unless otherwise indicated. 2)Refer to girder(s)for truss to truss connections. 3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSUTPI 1. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5)CAUTION,Do not erect truss backwards. LOAD CASE(S) Standard REp PR 0A-p. `-SS co tIGINE ,,,s �444 ' 8 • 2PE / � t‘‘'al, OREGO . `,/ BER \\ . s-IG A. HE P EXPIRES:06/30/2015 December 5,2014 : t A t iffhO Vedry deign pararneirrs au i READ 1461E5 074 THIS AK Ir7C2tSEf)MI7EK PEFE8EN E PAGE(477.7 473 reg,1115/2014 BEM(J5 Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer-riot truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the MiTek' erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding MFYI fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/IPI1 Quality Cdteda,DSB-89 and BCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 t#Southern Pin.(&P)tunshnx s specified,.the'ensign values WE those etioceive 06/03/els tuyA SC Job Truss Truss Type Qty Ply POLYGON R43360059 PL14-403 UPPER F14 Floor 5 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Fri Dec 55 09:53:09 2014 Page 1 ID:L209JJu6omRCBuYOhHV69uyFHbuc?pzgE90_Drl8k7BC7ble312CB7CUJou?563gyyCOvu 0-1-8 H I 1-1-12 1 2-6-0 Scale=1:41.7 4x6= 3x4= 3x4= 3x4 = 3x6 FP= 4x5= 1 2 3 4 5 6 7 8 9 10 11 12 a \ 7 7 IN ,, \ w 2 rse PM 19 18 17 16 15 14 13 3x4= 4x8= 3x6 FP= 3x5= 3x5= 4x6= 3x4= I, 1.5x3 SP= I 24-6-4 I 24-6-4 LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) 1/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.27 Vert(LL) -0.24 15-16 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.57 Vert(TL) -0.39 15-16 >738 360 BCLL 0.0 Rep Stress Incr YES WB 0.74 Horz(TL) 0.08 13 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:122 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 13=1067/Mechanical,19=1067/0-5-8 (min.0-1-8) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 2-3=-1842/0,3-4=-1842/0,4-5=-3235/0,5-6=-3235/0,6-7=-3396/0,7-8=-3396/0,8-9=-2330/0,9-10=-2330/0, 10-11=-2330/0 BOT CHORD 18-19=0/667,17-18=0/2678,16-17=0/2678,15-16=0/3456,14-15=0/3005,13-14=0/1324 WEBS 11-13=-1640/0,11-14=0/1247,8-14=-836/0,8-15=0/485,6-16=274/0,4-16=0/690,4-18=-1036/0,2-18=0/1456, 2-19=-1232/0 NOTES- 1)All plates are 1.5x3 MT20 unless otherwise indicated. 2)Refer to girder(s)for truss to truss connections. 3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5)CAUTION,Do not erect truss backwards. LOAD CASE(S) Standard ti_to PR QFp. �� iNESR s✓0 870 2PE y(11 04N '0j, OREGON i5 d 0 41BER tv 6 A,- HEP EXPIRES:06/3012015 December 5,2014 e AW.4R5 -Way deign iarametsrsanalREAD ffTES01/THIS AND/ICIER;€0?4I1EKR€FESEMTTPAC MIT 7473set J/16/20114 8FU55 .. Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component. Appliicabifrty of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown MiTis ek' for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the IYI�l��p erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding 1 fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TPI1 Quality Criteria,DSB-89 and SCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 1f Southern Pine ilsP).tsuTAW!it specified the dmagn values are thoseeltective 061031/201:3 by MSC Job Truss Truss Type Qty Ply POLYGON R43360060 PL14-403_UPPER F15 Floor 9 1 Job Reference(optional) Pacific Lumber 8 Truss Co., Lake Oswego,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Fri Dec 05 09:53:09 2014 Page 1 ID:L2O9JJu6omRCBuYOhHV69uyFHbuc?pzgE90_Drl8k7BC7ble314iBE1 UUiu?563gyyCOvu 1.5x5 II 0-10-8 � 2-60 1.5x3 1 2 3x4 = 3 Scale=1:13.0 II Mil 111 ,, 7 1.5x3= • 0 0 1.5x3= ►�,,, `� 6 5 =' 3x4= 3x4= 9-1-83-9-0 0.1- 3-7-8 LOADING(ps() SPACING- 1-7-3 CSI. DEFL. in (loc) I/defl Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.17 Vert(LL) 0.00 5 "" 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.06 Vert(TL) -0.02 4-5 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.04 Horz(TL) 0.00 4 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:23 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 3-9-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (Ib/size) 4=154/0-5-4 (min.0-1-8),5=154/Mechanical FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)Refer to girder(s)for truss to truss connections. 2)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4)CAUTION,Do not erect truss backwards. LOAD CASE(S) Standard Rtp PROFS. tIGINE 87022PE u? <C‘�r OREGO BER ‘,4 A. H EXPIRES::06/30/2015 December 5,2014 c r A WARN7f'.Verity deign pararamers and READ N217S CS THIS A C mums)MP7€X REFERS EE PAGE MU 7473 reg 1/25120i4DER"REUSE Design valid for use only with MTek connectors.Thu design is based only upon parameters shown,and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction's the responsibillity of the IY1-iQ�* erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding 1 fabrication,quality control,storage.delivery,erection and bracing,consult ANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute.781 N.Lee Sheet,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 tfSautitarn Pir,e$,SP}finT1ua:1sspecified,the Aesigaseohscs are Ilfase a#•ashes OG/Oaf2FRs.3 ALSC Job Truss Truss Type Oty Ply POLYGON R43360061 PL14-403_UPPER F16 FLOOR 2 1 Job Reference(optional) Pacific Lumber 8 Truss Co., Lake Oswego,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Fri Dec 05 09:53:10 2014 Page 1 ID:L2O9JJu6omRCBuYOhHV69uyFHbu-4CNMuaAeIXz9luiNmr6 AGID8bTmDmo2EIrcMOyCOvt f6-41 2-6-0 I Scale=1:41.8 4x6= 1.5x3 I I 1.5x3 I I 1.5x3 I I 3x4= 1.5x3 I I 3x4= 1.5x3 I I 3x4= 3x6 FP= 4x5= 1.5x3 I I 1 2 3 4 5 6 7 8 9 10 11 12 4. 'NN NN. i 7N'''''''''t dN 19 18 17 16 15 14 13 4x4 = 4x8= 3x6 FP= 3x5= 3x5= 4x6= 3x4= I 23-11-4 I 23-11-4 Plate Offsets(X Y)— [19:Edge.0-1-8] LOADING(psf) SPACING- 1-7-3 CSI. DEFL- in (loc) I/deft Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.26 Vert(LL) -0.22 15-16 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.54 Vert(TL) -0.37 15-16 >776 360 BCLL 0.0 Rep Stress Incr YES WB 0.76 Horz(TL) 0.08 13 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:119 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 13=1047/Mechanical,19=1047/Mechanical FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-1621/0,3-4=-1621/0,4-5=-3070/0,5-6=-3070/0,0.7=-3286/0,7-8=-3286/0,8-9=-2275/0,9-10=-2275/0, 10.11=-2275/0 BOT CHORD 18-19=0/421,17-18=0/2485,10.17=0/2485,10.16=0/3319,1415=0/2922,13-14=0/1296 WEBS 11-13=-1606/0,11-14=0/1213,8-14=-802/0,8-15=0/450,6-16=-308/0,416=0/724,418=-1071/0,2-18=0/1487, 2-19=-1135/0 NOTES- 1)Refer to girder(s)for truss to truss connections. 2)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard ti,?,c0 PR©Fes 870 2PE 1, c%,,,,OREGO if,4041S ER A s A. Heck EXPIRES:06/30/2015 December 5,2014 7 _ f ® N7.5€i-Vesityde_sipararameiersa,dREAfiOCTESCMTHIS.4NOL'KT.€XEDMITEK REFERENCE PAGEtfff7473see1/24/2108 BEMUSE Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component. �- Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown '! is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibility of the (AITe K" -- erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding Mile fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/1161 Quality Criteria,DSB-89 and SCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312.Alexandria,VA 22314. Citrus Heights,CA,95610 1f Southern,f+rs,e t5P)Iunn x is apex-AEA,rho desrge values axe these effer-tise 0€.103/201#byAISC • Job Truss Truss Type Qty Ply POLYGON R43360062 PL14-403_UPPER F17 Floor 10 1 Job Reference(optional) Pacific Lumber&Truss Co. Lake Oswego,Oregon 7.530 s Jul 11 2014 MTek Industries,Inc. Fri Dec 05 09:5311 2014 Page 1 ID:L209JJu6omRCBuY0hHV69uyFHbu-YOxkSwBGWg50N2HZKYdDjUrLR?r9yK3BSPbAuryCOvs 0-1-8 1, 21 2-5-8 I 2Fr0 I Scale=1:27.9 3x4 I I 1.5x3 II 1.5x3= 1.5x3= 3x4= 1.5x3 II 3x4= 1.5x3 I I 3x4= 1.5x3 I I 1 2 3 4 5 6 7 8 e to e_ e 5 7-NIt 0 c, DE 4 o e a -e 13 '*. 11 10 i 1.5x3 II 3x5= 3x5= 3x4= 3x6=- 0-7-4 0-7-4 121 I 16-0-12 5-5-12 I 15-5-8 0-1-8 LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) 1/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.48 Vert(LL) 0.06 11-12 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.34 Vert(TL) -0.10 10-11 >999 360 BCLL 0.0 Rep Stress Incr NO WB 0.31 Horz(TL) 0.02 9 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:84 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (Ib/size) 9=666/0-2-12 (min.0-1-8),12=1125/0-3-8 (min.0-1-8) Max Grav9=674(LC 4),12=1125(LC 1) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 3-4=-1249/0,4-5=-1249/0,5-6=-1256/0,6-7=-1256/0 BOT CHORD 11-12=0/773,10-11=0/1395,9-10=0/787 WEBS 2-12=-431/0,7-9=-975/0,7-10=0/582,3-11=0/603,3-12=-955/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)9. 3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5)CAUTION,Do not erect truss backwards. 6)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)400 lb down at 0-2-4 on top chord. The design/selection of such connection device(s)is the responsibility of others. 7)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). LOAD CASE(S) Standard cD PROP 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 Vs Fs Uniform Loads(plf) (jyj cS de Vert:9-13=-8,1-8=-80 C\� �i�G C, Concentrated Loads(Ib) j'' -� Vert:1=-400(F) �Q �PE 7(1) h '",,©REG N ©aW bOv 4SER V� Pr 61 04. 4. HE EXPIRES:06/30/2015 December 5,2014 6 A wfiANDiti Ye y, Eta*Yaranie rs alrr READ IFS ON THIS Ale DOMED MITF!£SEFEFEM.z PAGE MIT.7473 m c il 25/2014 DifonisE �"" Design valid for use only with MTek connectors.This design is based only upon parameters shown,and is for an individual building component. �' Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the 6 ,+ erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding Mi ek' fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/1P11 Quality Criteria,DSB-89 and SCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 If Sauthears Pine )laenhaq is spetifeu€,the design.valuesnrettrameffective 0e/01/2O1..3byALec Job Truss Truss Type Qty Ply POLYGON R43360063 PL14-403_UPPER F18 Floor 8 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc. Fri Dec 05 09:53:11 2014 Page 1 ID:L209JJu6omRCBuYOhHV69uyFHbu-YOxk5wBGWg5ON2HZKYdDjUrQh?u4yKEBSPbAuryCOvs I 1-7-0 I I 2-3-0I &14 Scale=1:19.4 1.5x3 I I 1.5x3= 1.5x3 I I 3x4= 1.5x3 II 3x4= 1.5x3= 1 3x4= 2 3 4 5 6 12 d N 11 10] 9 8 . 3x5= 3x5= 1.5x3 II 3x4= 11-2-8 I 11-7-8 LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) 1/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.14 Vert(LL) -0.01 8 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.16 Vert(TL) -0.05 7-8 >999 360 BCLL 0.0 Rep Stress Ina YES WB 0.30 Horz(TL) 0.01 7 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:60 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No,1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 10=482/0-2-12 (min.0-1-8),7=482/0-5-4 (min.0-1-8) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 1-10=-480/0,1-2=-391/0,2-3=-391/0,3-4=-713/0,4-5=-713/0 BOT CHORD 8-9=0/669,7-8=0/486 WEBS 5-7=-625/0,5-8=0/292,3-9=-357/0,1-9=0/581 NOTES- 1)Provide mechanical connection(by others)of truss to bearing plate at joint(s)10. 2)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/-PI 1. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4)CAUTION,Do not erect truss backwards. LOAD CASE(S) Standard ti .O PROPe. ,., lNE �4 s,,o29 870 2PE f cp 04 7 '0,,,,GREG N (1,Q,AO -P ''BER �' CSS k HSR-- EXPIRES:06/30/2015 December 5,2014 i 4 _ A C4i4RNMCi-Verify design raraxtu en 3iid READ PC TES Ott THIS AND IMITIi0E0 HTTE!t REFERENCE PAI3i MIT 7413 reg.,t/29/2.ogd 115E Design valid for use only with Mick connectors.This design is based only upon parameters shown,and is for an individual building component. I Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown MiTek* ■T '` a for lateral support of individual web members only.Additional temporary bracing to insure stability during construction a the responsibillity of the EYI)IpR' erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding {Yi R fabrication,quality control storage,delivery,erection and bracing,consult ANSI/TPIT Quality Criteria,DSB-89 and SCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute,781 N.Lee Street.Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 Ifseutbetn;Pine ISP)lumber isapacift &tiereest a values are those 06/01/ 33bvA SC Job Truss Truss Type Qty Ply POLYGON R43360064 PL14-403_UPPER F19 Floor 2 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Fri Dec 05 09:53:12 2014 Page 1 ID:L209JJu6omRCBuY0hHV69uyFHbu0aV61GBuH8Dt?BsmtGBSFhNaFP9LhhOLh3K]QHyCOvr 0-1-8 HI 1-7-8 ii 2-6-0 ] 0148 Scale=1:38.2 4x4= 3x4= 3x4= 3x4= 3x6 FP= 3x6= 2 3 4 5 6 7 8 9 10 11 e -\ ZINN. - m aNie. 1 2 a a 0 d a a 1 ,..,, 'o m o 21 -11H-11 A.E1 18 17 16 15 14 13 12 4x6= 3x6 FP= 3x8= 3x5= 3x8= 3x4= I 22-7-8 I 22-7-8 Plate Offsets(X.Y)- [1:Edge 0-1-8] LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/deft Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.22 Vert(LL) -0.17 14-15 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.47 Vert(TL) -0.29 14-15 >931 360 BCLL 0.0 Rep Stress Incr YES WB 0.65 Horz(TL) 0.06 12 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:115 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (Ib/size) 18=978/0-5-8 (min.0-1-8),12=978/0-5-4 (min.0-1-8) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 18-19=-978/0,19-20=-978/0,1-20=-978/0,1-2=-867/0,2-3=-867/0,3-4=-2507/0,4-5=-2507/0,5-6=-2911/0, 6-7=-2911/0,7-8=-2088/0,8-9=-2088/0,9-10=-2088/0 BOT CHORD 16-17=0/1830,15-16=0/1830,14-15=0/2850,13-14=0/2641,12-13=0/1202 WEBS 10-12=-1490/0,10-13=0/1097,7-13=-686/0,7-14=0/334,5-15=-425/0,3-15=0/840,3-17=-1193/0,1-17=0/1271 NOTES- 1)All plates are 1.5x3 MT20 unless otherwise indicated. 2)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/7P11. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard ,SD PROF `r• .8702PE f - ySATOREGON 1•P14/ 1 ��Bt R 1\ ©'. �S A- He ,�aP EXPIRES:06/30/2015 December 5,2014 _ f ®6-IRS/S i.Vcd/pxx/a;aranroers ax3 READ ND/PS ON THIS ANC matzo H.TFK REFEREA T PAGE 5117473 me 1/28/22359EFOREUSE Design valid for use only with Miles connectors.This design is based only upon parameters shown,and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the � ��* erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding fabrication,quality control storage,delivery,erection and bracing,consult ANSI/TPI1 Qualtiy Cdteda,DSB-B9 and BCSI Building Component 7777 Greenback Lane,Suite 109 Safely Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 IfSauthern.Pine(SN)lumbar is specified,dm design velum ace Mose effective Of401,2191:0 by Job Truss Truss Type Qty Ply POLYGON R43360065 PL14-403_UPPER F22 FLOOR GIRDER 2 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Fri Dec 05 09:53:14 2014 Page 1 ID:L2O9JJu6omRCBuYOhHV69uyFHbu-yzdsjxD8p1TbEV08?hAwL6SxmCtE9eDd8NpgV9yCOvp 10-941 2-60 1 0148 Scale=1:41.8 3x5= 1.5x3 II 3x6= 3x4 114x4 = 1.5x3 11 3x4= 1.5x3 II 3x4= 1.5x3 11 3x4= 3x6 FP= 3x4= 3x6= 1 2 3 4 5 6 7 8 9 10 11 12 i - — 7"1111111VNVII . 0 21 O N 1- n i � 20 19 18 17 16 15 14 13 4x6 = 3x6= 3x6 FP= 3x5= 3x5= 3x5= 3x10= 1 24-6-4 I 24-6-4 Plate Offsets(X Y)— [1:Edge.0-1-8] [12:0-2-0.Edge].[20:0-1-8.0-1-81.121:0-1-8.0-1-81 LOADING(psf) SPACING- 1-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.15 Vert(LL) -0.15 15-16 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.38 Vert(TL) -0.24 15-16 >999 360 BCLL 0.0 Rep Stress Incr NO WB 0.47 Horz(TL) 0.05 13 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:129 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 19=662/Mechanical,13=179210-5-8 (min.0-1-8) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 13-20=-1142/0,20-21=-1183/0,12-21=-1142/0,2-3=-1064/0,3-4=-1064/0,4-5=-1969/0,5-6=-1969/0,6-7=-2102/0, 7-8=-2102/0,8-9=-1468/0,9-10=-1468/0,10-11=-1468/0 BOT CHORD 18-19=0/314,17-18=0/1604,16-17=0/1604,15-16=0/2123,14-15=0/1874,13-14=0/856 WEBS 11-13=-1044/0,11-14=0/758,8-14=-503/0,8-15=0/282,4-16=0/452,4-18=-668/0,2-18=0/930,2-19=-729/0 NOTES- 1)Refer to girder(s)for truss to truss connections. 2)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4)CAUTION,Do not erect truss backwards. 5)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)1129 lb down at 24-2-8 on top chord. The design/selection of such connection device(s)is the responsibility of others. 6)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). LOAD CASE(S) Standard ���U PRO) 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 GINE u n Uniform Loads CD Vert:13P 9=-5,1-12=-50 C• 'c A Q�9 Concentrated Loads(Ib) 7 Vert:12=-1129(8) y, A S OREGO if'©!1! Os, A- HERP EXPIRES:06/30/2015 December 5,2014 i _ f A NARNffsS Yed'f dello;araa xlcrs x,:i READ WITS Chi TUTS Ale IMI(SEO HIIT.REFERENCE PAGE MIT 7473 its 1,12512C4 HEW FUSE Design valid for use only with Wink connectors.This design is based only upon parameters shown,and is for an individual building component. . Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown - - is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the - -- MiTek' erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding I fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TPII Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute,781 N.Lee Street.Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 it Southern Pile tSP)8aunt eu is specifiedd,dm dezign vatuits arethese effective OG101/101.3.IstALSC Job Truss Truss Type Qty Ply POLYGON R43360066 PL14-403_UPPER F23 Floor Supported Gable 1 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Fri Dec 05 09:53:14 2014 Page 1 . ID:L209JJu6omRCBuYOhHV69uyFHbu-yzdsjxD8plTbEV08?hAwL6Sz8Cy5915d8NpgV9yCOvp Scale=1:17.5 1 2 3 4 5 6 7 8 9 J I° J L° J J L° O d N ................................................................ 18 17 16 15 14 13 12 11 10 I 10-7-8 I 10-7-8 LOADING(ps() SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.06 Vert(LL) n/a - n/a 999 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.01 Vert(TL) n/a - n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.03 Horz(TL) 0.00 10 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:50 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 DF Stud/Std(flat) REACTIONS. All bearings 10-7-8. (Ib)- Max Gray All reactions 250 lb or less at joint(s)18,10,17,16,15,14,13,12,11 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)All plates are 1.5x3 MT20 unless otherwise indicated. 2)Gable requires continuous bottom chord bearing. 3)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web). 4)Gable studs spaced at 1-4-0 oc. 5)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 6)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard A?,.V° PR°Fe. �� 4Co N�'jN �� 'lQ17 Q 870 2PE f `" -y �A.),OREGON QI' G N4 A. Heb EXPIRES:06/30/2015 December 5,2014 e f AWrr(61fPa3-V:'pdesignporsu srsaF,-PEWd0TES OHTHIS AND MIXED H17€K RUMEN'PAGEANT.7473mg.1/25/2s21aR EUS _ Design valid for use only with Mifek connectors.This design is based only upon parameters shown,and is for an individual building component. 'x Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown B for lateral support of individual web members only.Additional temporary bracing to insure stability during construction B the responsibillify of the MiTek erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/1911 Quality Criteria,055-89 and SCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 I€Sautiarnprssw tSP)Ilurrakk4gxis npasiflrai,M.aasign>values err those effective 000s/201.3 by MSC Job Truss Truss Type Qty Ply POLYGON R43360067 PL14-403_UPPER F25 Floor 6 1 Job Reference(optional) Pacific Lumber 8 Truss Co., Lake Oswego,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Fri Dec 05 09:53:15 2014 Page 1 ID:L2O9JJu6omRCBuYOhHV69uyFHbu-Q9AFxHEna3bSsfbKZOh9tK?5ZcBCu3GnN1ZN1cyCOvo 11-5-0 I I 2-6-0 I Scale=1:38.7 1.5x3 II 4x4= 1.5x3 II 3x4= 1.5x3 II 3x4 = 1.5x3 II 3x4= 3x6 FP= 4x4= 1.5x3 II 1 2 3 4 5 6 7 8 9 10 11 ikc :-.. 7, ANN..7...ANN:-.yoeio., NsiNN..-7 .1e n e e e ,1 �1 18 17 16 15 14 13 12 1.5x3 II 4x6= 3x6 FP= 3x6= 3x5= 3x8= 3x4= I 22-2-0 I 22-2-0 Plate Offsets(X Y)— (1:Edge,0-1-81 LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/defl Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 021 Vert(LL) -0.17 14 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.46 Vert(TL) -0.28 14-15 >952 360 BCLL 0.0 Rep Stress lncr YES WB 0.61 Horz(TL) 0.06 12 n/a n/a BCDL 5.0 Code IBC20121TP12007 (Matrix) Weight:110 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 18=969/0-2-12 (min.0-1-8),12=969/0-2-8 (min.0-1-8) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 1-18=-971/0,1-2=-766/0,2-3=766/0,3-4=-2432/0,4-5=-2432/0,5-6=-2861/0,6-7=-2861/0,7-8=-2063/0, 8-9=-2063/0,9-10=-2063/0 BOT CHORD 16-17=0/1743,15-16=0/1743,14-15=0/2788,13-14=0/2604,12-13=0/1190 WEBS 10-12=-1475/0,10-13=0/1081,7-13=-670/0,7-14=0/319,5-15=-440/0,3-15=0/855,3-17=-1210/0,1-17=0/1206 NOTES- 1)Provide mechanical connection(by others)of truss to bearing plate at joint(s)18,12. 2)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSIfTPI 1. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard RE-O PROpe, iv�,� � ')lVEfi'7 0.0,. 87022PE v" N 7 �11' �, OREG N '1b Q1 On BER \' yr S ,�. HEN EXPIRES:06/30/2015 December 5,2014 1 - f A IMP17MS Verity design Yamrtteirs and READ ON THIS AND mama)will REFERENCE PAGE Pff7�7813 me 1/19/28148 x tB5€ Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component. � Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown __ is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the 'r^ erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.for general guidance regarding MiTekIl fabrication,quality control storage,delivery,erection and bracing,consult ANSI/TPII Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane,Suite 109 Safely Information available from Truss Plate Institute,781 N.Lee Street.Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 t#Southern f bre(SP)lumber Iser ifred,the design veitoes are these effective 06/01rm13 IpA£SC Job Truss Truss Type Qty Ply POLYGON R43360068 PL14-403_UPPER F26 Floor 2 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Fri Dec 05 09:53:15 2014 Page 1 ID:L2O9JJu6omRCBuYOhHV69uyFHbu-Q9AFxHEna3bSstbKZOh9tK766cHVuCOnN1ZN1cyCOvo 1.5x:) II 2-1-4 2-6x{1 T.5x3 11 1 2 3x4 = 3 Scale=1:12.9 J � N 5 4 3x4 = 3x4= 00-8 4-10-4 I 0.1-8 4-8-12 LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (lac) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.18 Vert(LL) 0.00 5 "" 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.12 Vert(TL) -0.08 4-5 >745 360 BCLL 0.0 Rep Stress Ina YES WB 0.05 Horz(TL) 0.00 4 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:26 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.18&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 4-10-4 oc purlins, except BOT CHORD 2x4 DF No.18,Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 4=208/0-2-0 (min.0-1-8),5=208/0-2-12 (min.0-1-8) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)Provide mechanical connection(by others)of truss to bearing plate at joint(s)4,5. 2)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard cs\Ep PRO s xi 870 2PE to `��, OREGO . 0 �6/SRO\ ' CSk HE P EXPIRES:06/30/2015 December 5,2014 e r A WARNDE Verity dxrlsram npaeGtsand hMIES CM THIS AleI,?KS.t:S£f)NITEK REFERENCE PAGE ma 7473rceI/1/20163PT,.4EL,E Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown _'` is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the �TeK• erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding 1 fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TPI1 Quality Cdteria,DSB-89 and BCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 1f Southern Pine f5A).bwstsar is sfaasified,thee-eel/in valuer art Chase-a ective 06/011201.3 byA SC Job Truss Truss Type Oty Ply POLYGON R43360069 PL14-403 UPPER F28 Floor 2 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Fri Dec 05 09:53:16 2014 Page 1 I D:L2O9JJu6omRCBuYOhHV69uyFHbu-vMkd8dEP LNkJTp9X65DOOXYFNOW IdUcwchlx22yCOvn 1 1-3-4 1 2-6-0 1 Scale=1:42.8 1.5x3 II 4x6= 1.5x3 I I 3x4= 1.5x3 II 3x4= 1.5x3 II 3x4=3x6 FP=1.5x3 I I 4x5= 1.5x3 I I 1 2 3 4 5 6 7 8 9 10 11 12 g AA c ,,,,N.a e 7 a\````` e e 7 7 N...,....., 7 2, \B B B 19 18 17 16 15 14 13 3x4 = 4x8= 3x6 FP= 3x5= 3x5= 5x6= 3x4= 1.5x3 SP= I 24-6r4 I 24-6-4 LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) 1/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.27 Vert(LL) -0.24 15-16 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.57 Vert(TL) -0.40 15-16 >728 360 BCLL 0.0 Rep Stress Incr YES WB 0.73 Horz(TL) 0.08 13 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:121 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (Ib/size) 13=1073/Mechanical,19=1073/0-3-4 (min.0-1-8) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-1902/0,3-4=-1902/0,4-5=-3280/0,5-6=-3280/0,6-7=-3426/0,7-8=-3426/0,8-9=-2345/0,9-10=-2345/0, 10-11=-2345/0 BOT CHORD 18-19=0/735,17-18=0/2731,16-17=0/2731,15-16=0/3494,14-15=0/3027,13-14=0/1331 WEBS 11-13=-1650/0,11-14=0/1256,8-14=-846/0,8-15=0/494,6-16=-265/0,4-16=0/680,4-18=-1027/0,2-18=0/1447, 2-19=-1268/0 NOTES- 1)Refer to girder(s)for truss to truss connections. 2)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard � c-j�( 0 PR Ore ct 87022PE c tvsr /� r y 10),OREGO © Q1.1 �G'�fiwSER 1t >.. A. HE EXPIRES:06/30/2015 December 5,2014 k 1 A WAR,Nft43.Vrc/(f design paramemrs uort REM I MESON TH/S AND maim H17€K mFaaa PACE f4ff 7473 re& 1.11/2512014BEFCEfEl. . �" Design valid for use only with Mick connectors.This design s based only upon parameters shown,and is for an individual building component. Applicability of design parameters and proper incorporation of component n responsibility of building designer-not truss designer.Bracing shown. is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the Mitek" erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding fabrication,quality control storage,delivery,erection and bracing,consult ANSI/Tell Quaifly Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane,Suite 109 Safety information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 Southern Smern Pine(SF)Lumber is 11se design osfztes aft these affective 06/saa r s toy ALBC Job Truss Truss Type Qty Ply POLYGON R43360070 PL14-403_UPPER F40 FLOOR SUPPORTED GABL 12 1 Job Reference(optional) Pacific Lumber 8 Truss Co., Lake Oswego,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Fri Dec 05 09:53:17 2014 Page 1 ID:L209JJu6omRCBuY0hHV69uyFHbu-NYI?MzF15gs95zIggpkdyl4UwQzsM6K4rL2U6UyCOvm 1-0.8 1.5x3 II 1 3x4= 2 Scale=1:13.2 0 0 4 1.5x3 I I 3x4= 0-l-0 1-3-8 Q 3 1-3-8 LOADING(psf) SPACING- 1-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.03 Vert(LL) 0.00 4 """" 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.00 Vert(TL) -0.00 4 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:11 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 1-3-8 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 4=32/1-3-11 (min.0-1-8),3=32/1-3-11 (min.0-1-8),3=32/1-3-11 (min.0-1-8) FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web). 2)Gable studs spaced at 1-4-0 oc. 3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard PRQFes 87022PE tkaAFREG•N2 k/ BEFON 4 EXPIRES:06/30/2015 December 5,2014 e 4 A WARNINS.Vedfydvvlx ardnseers and oE/:)ICTES 0/rMIS AMMUM 41TEK FIFEREMT pAsE74177413soc1„'15/2074DEP MEtUSE Design valid for use only with Wick connectors.This design is based only upon parameters shown,and is for on individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the MiTek' erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/4911 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane,Suite 109 Salety Informalon available from Truss Plate Institute,781 N.Lee Street.Suite 312.Alexandria.VA 22314. Citrus Heights,CA,95610 if Southern rine ISP)tsmsteer is specified,.the el.rstgo us.luws are tease atfestreat O6/O1/2O13ASC Job Truss Truss Type Oty Ply POLYGON R43360071 PL14-403_UPPER F41 FLOOR SUPPORTED GABL 3 1 Job Reference(optional) Pacific Lumber 8 Truss Co., Lake Oswego,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Fri Dec 05 09:53:17 2014 Page 1 ID'L2O9JJu6omRCBuYOhHV69uyFHbu-NYI?MzF15gs95zkjgpkdyl4U?QztM6K4rL2U6UyCOvm 0-11-4 1.15x3 II 1 3x4= 2 Scale=1:13.2 0 0 c. 4 Vg 1.5x3 II 3x4= I r s 1-2-4 I 0-0 3 1-2-4 LOADING(psf) SPACING- 1-0-0 CSI. DEFL. in (lac) I/defl lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.02 Vert(LL) 0.00 4 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.00 Vert(TL) -0.00 4 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 3 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:11 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 1-2-4 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 4=29/1-2-7 (min.0-1-8),3=29/1-2-7 (min.0-1-8),3=29/1-2-7 (min.0-1-8) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web). 2)Gable studs spaced at 1-4-0 oc. 3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard �4`£D PR Q,r s 444 17 5 3 k4E- ✓�; 87O22PE f� , ' ry 7 -0/, OREG N t1 1 'p�MQER 1\ v., A. He EXPIRES:06/30/2015 December 5,2014 6 A WARMIf` Verify design arasaeers a4:i REAP NOTES C/4 THIS AND MIMED OSED?MITE(REFERENCE PAGE MIT 7473 rc4/125/201$BETPEYSE. il . a Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and k for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during constriction B the responsibillity of the ,Bj�,T��* erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding IYB f fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TP11 Qualty Criteria,DSB-89 and SCSI Building Component 7777 Greenback Lane,Suite 109 Safety Informaton available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 ft Saurtiseen Prue(SP)tuen1san is specified,xhedestgrs ensues wart/rasa effective oG/02f2013 top A&SC Job Truss Truss Type Qty Ply POLYGON R43360072 PL14-403_UPPER F42 FLOOR SUPPORTED GABL 3 1 Job Reference(optional) Pacific Lumber S Truss Co., Lake Oswego,Oregon 7.530 S Jul 11 2014 MiTek Industries,Inc.Fri Dec 05 09:53:17 2014 Page 1 ID:L2O9JJu6omRCBuYOhHV69uyFHbu-NYI?MzF15gs95zlgpkdyl4UPQzpM6K4rL2U6UyCOvm I 1-6-4 1.5x3 II 1 3x4= 2 Scale=1:13.2 0 0 • • 1.5x3 II 3x4= r.r 1-9-4 I r r 1-9-4 LOADING(psf) SPACING- 1-0-0 CSI. DEFL. in (loc) I/deft Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.06 Vert(LL) 0.00 4 "" 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.01 Vert(TL) -0.00 4 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 3 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:13 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 1-9-4 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 4=45/1-9-8 (min.0-1-8),3=45/1-9-8 (min.0-1-8),3=45/1-9-8 (min.0-1-8) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web). 2)Gable studs spaced at 1-4-0 oc. 3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard �V PR OFFS cl; 8 f 2PE r , i EXPIRES:06/30/2015 December 5,2014 f A KAM .Ver r*Alga parameters a Add READ l TES ON THIS name EU MITEK 1€EFEREM7 mar MIT 7 473 seg.I/29MM BEORE Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown Mil is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the MiTek erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding IXl 1 fabrication,quality control,storage,der>ery,erection and bracing,consult ANSI/TP11 Quality Criteda,DSB-89 and SCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 tf SeutherePine(•MP}tsrsrrt it osfrd,the denim values are was= OG/01/201.3 by MSC Job Truss Truss Type Qty Ply POLYGON R43360073 PL14 403_UPPER F43 FLOOR SUPPORTED GABL 3 1 Job Reference(optional) Pacific Lumber 8 Truss Co., Lake Oswego,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Fri Dec 05 09:53:18 2014 Page 1 ID:L2O9JJu6omRCBuYOhHV69uyFHbu-rksNZJGfs_0j6JvEWFsVydfxpJ75ZaD3?n1 exyCOvl 1.5x3 II 1 4x4= 2 Scale=1:13.3 z I 4 3 1.5x3 II 4x4= 0-1.0 0-11-0 0-01-2 0-11-0 Plate Offsets(X.Y)— [1:Edge.0-1-8].[3'Edge.0-1-8] LOADING(psf) SPACING- 1-0-0 CSI. DEFL. in (roc) 1/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.01 Vert(LL) n/a - n/a 999 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.00 Vert(TL) n/a - n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 3 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:10 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 0-11-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 4=22/0-11-2 (min.0-1-8),3=22/0-11-2 (min.0-1-8) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)Gable requires continuous bottom chord bearing. 2)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web). 3)Gable studs spaced at 1-4-0 oc. 4)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard �_tr) PRore�S c';‘,� �GI N ��oy-X" 87022PE 04 ,G�, (?REG N 41' 0./ On Sept EXPIRES:0£/3W2015 December 5,2014 a e A W NAND E-Veristy design raisxsx L+m usd READ IC TES ON THIS MC:M 7AtU€D H1TEK REFERENCE PAGE/477 7473 res 1/29V2L!t£BEMUSE Design valid for use only with MTek connectors.This design k based only upon parameters shown,and is for an individual building component. �+ Applicability of design parameters and proper incorporation of component B responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibility of the MiTek* - - - erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TPI1 Quality Cdfeda,D5B-89 and SCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 tn If Southern.Pe)CP)typifier is specified,the dega s values are those effect-Me 06,01/2013 tryAt:SC Job Truss Truss Type Qty Ply POLYGON R43360074 PL14-403_UPPER F44 FLOOR SUPPORTED GABL 3 1 Job Reference(optional) Pacific Lumber&Tess Co., Lake Oswego,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc. Fri Dec 05 09:53:18 2014 Page 1 ID:L209JJu6omRCBuYOhHV69uyFHbu-rksNZlGfs_Oj6JvEV1FsVydfgpJ65ZaD3?n1 exyCOvl I 0-10-0 1.5x3 II 1 3x4 = 2 Scale=1:13.2 a ebb. 1.5x3 II 3x4= r r r 1-1-0 0-r 2 1-1-0 LOADING(psi) SPACING- 1-0-0 CSI. DEFL. in (loc) I/deft Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.02 Vert(LL) 0.00 4 "" 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.00 Vert(TL) -0.00 4 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 5.0 Code IBC2012/1-P12007 (Matrix) Weight:10 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 1-1-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 4=26/1-1-2 (min.0-1-8),3=26/1-1-2 (min.0-1-8),3=26/1-1-2 (min.0-1-8) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web). 2)Gable studs spaced at 1-4-0 oc. 3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard Ep PROE 44/ 87022PE �� IV (1)'s OREGO ti 006% ER A. HE EXPIRES:06/30/2015 December 5,2014 fi tt:4RAi7;`-Ycd/y design raara fsrs oral Or TES ON THIS NC MUM PAGE Mir 1413 mx 1,125/2014 BffOREUSE Design valid for use only with Mick connectors.This design is based only upon parameters shown.and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown 111111 is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the a��T�'Bl`^ erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding 19i 1 fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/Tell Quality Crfeda,D5B-89 and BCSI Boning Component 7777 Greenback Lane,Suite 109 Safely Information available from Truss Plate Institute,781 N.Lee Sheet,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 If&avtham Pine f5P71aaetnaes xpecifiesis the dcsige Nsaistsm are thafx:affective re/DS/oras1sy.AaSC Job Truss Truss Type Qty Ply POLYGON R43360075 PL14-403 UPPER F45 FLOOR SUPPORTED GABL 4 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Fri Dec 05 09:53:19 2014 Paget ID:L2O9JJu6omRCBuYOhHV69uyFHbu-JxQlmfHHdl6tKGu6oEm52AAgDDfJgOqMIfXbANyCOvk 1-3-0 1.5x3 I I 3x4= 2 Scale=1:13.2 , d ♦•♦♦♦•♦•...... .. op--< .... .. . , 1.5x3 II 3x4= 0.Q-0 1-6-0 0. 1-6-0 LOADING(psf) SPACING- 1-0-0 CSI. DEFL. in (loc) 1/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.04 Vert(LL) 0.00 4 "" 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.00 Vert(TL) -0.00 4 >999 360 BCLL 0.0 Rep Stress!nor YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:12 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 1-6-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 4=38/1-6-4 (min.0-1-8),3=38/1-64 (min.0-1-8),3=38/1-6-4 (min.0-1-8) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web). 2)Gable studs spaced at 1-4-0 oc. 3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard ���c o PROF ss c>; 8 • 2PE r r U) 7 A), OREGO 441 ti •PO4•4i \� �ts4 A. Heck EXPIRES:06/3W2015 December 5,2014 A WAJWTN3-VeritydeuJJs paarnemrs and READ RO TES ON MIS AM mama N1?EK R£FEP)MI P,AOE MIT 7473 rex I/19/28u wpm115E Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component. �r Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the R � Q'j- - -- erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TPIl Quality Criteria,DSB-89 and BCSI Betiding Component 7777 Greenback Lane,Suite 109 Safety Informalon available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 It saa harem Pirie(EPI lumbar is upariti rd.thedesian values are:ltrare orartasre 06/03/2013 ay MSC Job Truss Truss Type Qty Ply POLYGON R43360076 PL14-403_UPPER F47 FLOOR SUPPORTED GABL 2 1 Job Reference(optional) Pacific Lumber 8 Truss Co., Lake Oswego,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Fri Dec 05 09:53:19 2014 Page 1 ID:L209JJu6omRCBuYOhHV69uyFHbu-JxQImfHHdl6tKGu6oEm52AAgpDfNgOgMIfXbANyCOvk 7x10 I I 1 2 Scale=1:13.3 0 c a 4 3 7x10 I I 0-9-0 0-7-4 a 0-7-4 Plate Offsets(X Y)— [1:Edge 0-1-8] [4:Edge.0-1-8] LOADING(psf) SPACING- 1-0-0 CSI. DEFL. in (loc) 1/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.00 Vert(LL) n/a - n/a 999 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.00 Vert(TL) n/a - n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 10.0 Code IBC2012/TP12007 (Matrix) Weight:9 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 0-7-4 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 4=14/0-7-8 (min.0-1-8),3=14/0-7-8 (min.0-1-8) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)Gable requires continuous bottom chord bearing. 2)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web). 3)Gable studs spaced at 1-4-0 oc. 4)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard P} OE fistS <c. NG1 N,E ,Q2-9 870 2PE yAT OREGON (1,.(:'),44/ FSSER A' EXPIRES:06/3012015 December 5,2014 4 f 64AulN1.'-yerftr design paranxters and READ ROTES 04 WS AND mama MSTER P's£F:TME107!PAGE MIT 7473 re 1 29/2 Pd BL3REUS?' Design valid for use only with MTek connectors.This design is based only upon parameters shown,and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown Mil is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the resporuibillity of the - Tek' erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding MiTek' fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane,Suite 109 Safely Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 liSouthern Plsv}lsrataexi spacified,the design wares are there effective /81/2013ay AMSC Symbols Numbering System A General Safety Notes PLATE LOCATION AND ORIENTATION 1 3/" Center plate on joint unless x,y 6-4-8 dimensions shown in ft-in-sixteenths Failure to Follow Could Cause Property 4 offsets are indicated. I I (Drawings not to scale) Damage or Personal Injury NM= Dimensions are in ft-in-sixteenths. iiimAhh„ Apply plates to both sides of truss 1 2 3 1. Additional stability bracing for truss system,e.g. and fully embed teeth. diagonal orX-bracing,is always required. See BCSI. TOP CHORDS 01 „ 2. Truss bracing must be designed by an engineer.For '/16 wide truss spacing,individual lateral braces themselves may require bracing,or alternative Tor I 111111111E O ILslIplizilki ,:„. bracing should be considered. �_� O 3. Never exceed the design loading shown and never stack materials on inadequately braced trusses. ~ c�-e C6.7 cs 6 o 4. Provide copies of this truss design to the building For 4 x 2 orientation,locate , designer,erection supervisor,property owner and plates 0-'na from outside BOTTOM CHORDS all other interested parties. edge of truss. 8 7 6 5 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each This symbol indicates the JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE joint and embed fully.Knots and wane at joint - required direction of slots in AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO locations are regulated by ANSI/TPI 1. connector plates. THE LEFT. 7. Design assumes trusses will be suitably protected from "Plate location details available In MiTek 20/20 CHORDS AND WEBS ARE IDENTIFIED BY END JOINT the environment in accord with ANSI/TPI 1. software or upon request. NUMBERS/LETTERS. 8. Unless otherwise noted,moisture content of lumber shall not exceed 19%at time of fabrication. PLATE SIZE PRODUCT CODE APPROVALS 9. Unless expressly noted,this design is not applicable for ICC ES Reports: use with fire retardant,preservative treated,or green lumber. The first dimension is the plate 10.Camber is a non-structural consideration and is the 4 x 4 width measured perpendicular ESR-1311,ESR-1352,ESR1988 responsibility of truss fabricator.General practice is to to slots.Second dimension is ER-3907,ESR 2362,ESR 1397,ESR 3282 camber for dead load deflection. the length parallel to slots. 11.Plate type,size,orientation and location dimensions indicated are minimum plating requirements. LATERAL BRACING LOCATION 12.Lumber used shall be of the species and size,and Southern Pine lumber designations are as follows: in all respects,equal to or better than that , Indicated by symbol shown and/or SYP represents values as published specified. bytext in the bracingsection of the by AWC in the 2005/2012 NDS SP represents ALSC approved/new values 13.Top chords must be sheathed or purlins provided at output. Use T or I bracing with effective date of June 1,2013 spacing indicated on design. If indicated. 14.Bottom chords require lateral bracing at 10 ft.spacing, BEARING or less,If no ceiling is Installed,unless otherwise noted. 15.Connections not shown are the responsibility of others. *IL, Indicates location where bearings 16.Do not cut or alter truss member or plate without prior (supports) occur. Icons vary but ©2012 MiTek®All Rights Reserved approval of an engineer. ■.111reaction section indicates joint number where bearings occur. 17.Install and load vertically unless indicated otherwise. Min size shown is for crushing only. 18.Use of green or treated lumber may pose unacceptable ► environmental,health or performance risks.Consult with Industry Standards: 11 ANSI/TPI1: National Design Specification for Metal 01.140 project engineer before use.19.Review all portions of this design(front,back,words Plate Connected Wood Truss Construction,9and pictures)before use.Reviewing pictures alone DSB-89: Desi n Standard for Bracing. is not sufficient. 9� MiTeke BCSI: Building Component Safety Information, 20.Design assumes manufacture in accordance with Guide to Good Practice for Handling, ANSI/TPI 1 Quality Criteria. Installing&Bracing of Metal Plate Connected Wood Trusses. MiTek Engineering Reference Sheet:MII-7473 rev.01/29/2013