Report ,. t1112c1Worldwide Fire Protection Contacts www.tyco-fire.com Products Series TY-FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General NOTICE The TYCO Series TY-FRB Sprinklers - Description described herein must be installed and . maintained in compliance with this doc- The TYCO Series TY-FRB,5.6 K-factor, ument, as well as with the applicable Upright(TY313) and Pendent(TY323) standards of the National Fire Protec- Sprinklers described in this data sheet tion Association,in addition to the stan- are quick response,standard coverage, dards of any other authorities having decorative 3 mm glass bulb-type spray jurisdiction.Failure to do so may impair ",` `' , ' sprinklers designed for use in light or the performance of these devices. . ` W \ fix, ordinary hazard,commercial occupan cies such as banks, hotels,and shop The owner is responsible for maintain -- ping malls. ing their fire protection system and devices in proper operating condition. The recessed version of the Series TY- The installing contractor or sprinkler FRB Pendent Sprinkler,where applica- manufacturer should be contacted with ble, is intended for use in areas with a any questions. finished ceiling.This recessed pendent sprinkler uses one of the following: j • A two-piece Style 15 Recessed Sprinkler ;" P, Escutcheon with recessed adjust f e ment up to 5/8 inch (15,9 mm)from Identification {, the flush pendent position. Number (SIN) ,. ` • A two-piece Style 20 Recessed Escutcheon with recessed adjust- TY313 Upright 5.6K, 1/2"NPT �' ment up to 1/2 inch (12,7 mm)from TY323 Pendent 5.6K, 1/2""NPT :. the flush pendent position. The adjustment provided by the Technical Recessed Escutcheon reduces the Temperature Rating accuracy to which the fixed pipe drops Data 135°F(57°C) to the sprinklers must be cut. 155°F(68°C) 175°F(79°C) Intermediate level versions of Series Approvals 200°F(93°C) TY-FRB Sprinklers are described in UL and C-UL Listed 286°F(141°C) Technical Data Sheet TFP357. Sprin- FM, LPCB,and VdS Approved kler guards and shields are described CE Certified Finishes in Technical Data Sheet TFP780. Sprinklers with Polyester Finish are UL Sprinkler: Refer to Table A and C-UL Listed as Corrosion-Resis- Recessed Escutcheon:White Coated, tant Sprinklers. Chrome Plated,or Brass Plated Maximum Working Pressure Physical Characteristics 175 psi(12.1 bar) Frame Bronze 250 psi(17.2 bar)* Button Brass/Copper *The maximum working pressure of 250 psi Sealing Assembly Stainless IMPORTANT (17.2 bar)only applies to the listing by Un- Steel w/TEFLON Always refer to Technical Data derwriters Laboratories,Inc.(UL). Bulb Glass Sheet TFP700 for the "INSTALLER Discharge Coefficient Compression Screw Bronze WARNING"that provides cautions K=5.6 GPM/psiii2(80,6 LPM/bar"2) Deflector Bronze with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 FEBRUARY 2014 TFP172 TFP172 Page 2 of 4 Components: *Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16"(11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON o'i7iT7 ITrIrYT 1.1�1A� \ i - ^IR�\�\ 5 �.5• 7/16" YI \ (11,1 mm) 1 1■FM 4 ( NOMINAL 2" �� [II* MAKE-IN 6.4- (50,8 mm) J al 11111 , 2 p• 2" 1-3/8 3 �� (50,8 mm) (34,9 mm) I I J WRENCH 1 f / 1 l f / Z = FLATS 1/2"NPT** DEFLECTOR* F _ 2-7/8"(73,0 mm)DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT(TY313)AND PENDENT(TY323)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE L, Operation Installation WRENCH RECESS The glass bulb contains a fluid which The TYCO Series TY-FRB,5.6 K-factor, expands when exposed to heat.When Upright(TY313)and Pendent(TY323) (USE ONLY the rated temperature is reached, the Sprinklers must be installed in accor- .. 07e. END"A") fluid expands sufficiently to shatter the dance with this section. ^� glass bulb, allowing the sprinkler to activate and water to flow. General Instructions FIGURE 2 Do not install any bulb-type sprinkler if W-TYPE 6 the bulb is cracked or there is a loss SPRINKLER WRENCH Design of liquid from the bulb.With the sprin- kler held horizontally, a small air bub- - Criteria ble should be present. The diameter WRENCH of the air bubble is approximately 1/16 RECESS The TYCO Series TY-FRB,5.6 K-factor, inch (1,6 mm)for the 135°F(57°C)and Upright(TY313)and Pendent(TY323) 3/32 inch(2,4 mm)for the 286°F(141°C) ��� Sprinklers are intended for fire protec- temperature ratings. /tom tion systems designed in accordance ir with the standard installation rules rec- ognized by the applicable Listing or should be obtained by applying a min Approval agency(such as, UL Listing imum to maximum torque of 7 to 14 S� is based on the requirements of NFPA ft.-lbs. (9,5 to 19,0 Nm). Higher levels Ni......, 13, and FM Approval is based on the of torque can distort the sprinkler Inlet requirements of FM's Loss Prevention with consequent leakage or impairment PUSH WRENCH Data Sheets).Only the Style 15 or Style of the sprinkler. IN TO ENSURE 20 Recessed Escutcheon is to be used Do not attempt to compensate for ENGAGEMENT for recessed pendent installations. insufficient adjustment in the Escutch- WITH SPRINKLER WRENCHING AREA eon Plate by under-or over-tightening FIGURE 3 the sprinkler. Re-adjust the position of W-TYPE 7 RECESSED the sprinkler fitting to suit. SPRINKLER WRENCH Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1.Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- - tighten the sprinkler into the sprinkler fitting. TFP172 Page 3 of 4 , Step 3.Tighten the sprinkler into the 2-7/8" DIA. sprinkler fitting using only the W-Type - (73,0 mm) - 6 Sprinkler Wrench(Figure 2).With ref- erence to Figure 1,apply the W-Type 6 2-1/4" DIA. Sprinkler Wrench to the wrench flats. FACE OF — (57,2 mm) —' Torque sprinklers 7 to 14 ft.-lbs.(9,5 to SPRINKLER 19,0 Nm). FITTING 5/8"(15,9 mm) Recessed Pendent Sprinklers \ - FLUSH The Series TY-FRB Recessed Pendent 3/8±5/16" _'1 I I Sprinklers must be installed in accor- (9,5±7,9 mm) zui i dance with the following instructions. } / , '% I Step A.After installing the Style 15 or MOUNTING S • 1/8" Style 20 Mounting Plate over the sprin- SURFACE (3,2 mm) kler threads, and with pipe-thread --— sealant applied to the pipe threads, CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) hand-tighten the sprinkler into the TY-FRB PLATE 3/4" sprinkler fitting. (19,1 mm) Step B.Tighten the sprinkler into the FIGURE 4 Step B. fitting using onln the W-Tthe SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) 7spriRecessed SprinkleruinWrench (Figure WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 3).With reference to Figure 1,apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque _ 2-7/8" DIA. , sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 (73,0 mm) Nm). FACE OF Step C.After ceiling installation and fin- SPRINKLER 2-1/4" DIA. fishing,slide on the Style 15 or Style 20 FITTING (57,2 mm) Closure over the Series TY-FRB Sprin- 5/16±1/4" kler and push the Closure over the (7,9±6,4 mm) 1/2"(12,7 mm) Mounting Plate until its flange comes in + FLUSH contact with the ceiling. Care and f / MOUNTING 1110 1/8" J} Maintenance SURFACE (3,2 mm) The TYCO Series TY-FRB,5.6 K-factor, I Upright(TY313) and Pendent(TY323) CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) Sprinklers must be maintained and ser- TY-FRB PLATE 7/8"(22,2 mm) viced in accordance with this section. FIGURE 5 Before closing a fire protection system SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) main control valve for maintenance WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 work on the fire protection system RECESSED ESCUTCHEON that it controls, obtain permission to shut down the affected fire protection Modified sprinklers must be replaced. standards of any other authorities hay- systems from the proper authorities Sprinklers that have been exposed to ing jurisdiction. Contact the installing and notify all personnel who may be corrosive products of combustion, but contractor or sprinkler manufacturer affected by this action. have not operated,should be replaced regarding any questions. Absence of the outerpiece of an if they cannot be completely cleaned by wiping the sprinkler with a cloth or Automatic sprinkler systems are rec- escutcheon, which is used to cover by brushing it with a soft bristle brush. mended to be inspected, tested, a clearance hole, can delay sprinkler and maintained by a qualified Inspec- operation in a fire situation. Care must be exercised to avoid dam- tion Service in accordance with local The owner must assure that the sprin- age to the sprinklers before,during,and requirements and/or national codes. klers are not used for hanging any after installation. Sprinklers damaged objects and that the sprinklers are only by dropping, striking, wrench twist/ cleaned by means of gently dusting slippage,or the like,must be replaced. with a feather duster;otherwise, non- Also, replace any sprinkler that has a operation in the event of a fire or inad cracked bulb or that has lost liquid from vertent operation may result. its bulb.(Ref. Installation Section.) Sprinklers which are found to be leak- The owner is responsible for the ing or exhibiting visible signs of corro inspection,testing,and maintenance of sion must be replaced. their fire protection system and devices in compliance with this document, as Automatic sprinklers must never be well as with the applicable standards painted, plated, coated, or other- of the National Fire Protection Associa- wise altered after leaving the factory. tion (e.g., NFPA 25), in addition to the TFP172 Page 4 of 4 P/N* 77 - XXX - X - XXX � I SPRINKLER TEMPERATURE FINISH RATINGS SIN 1 NATURAL BRASS 135 135°F(57°C) 370 5.6K UPRIGHT(1/2"NPT) TY313 g PURE WHITE(RAL9010)** 155 155°F(68°C) POLYESTER SIGNAL WHITE(RAL9003) 371 5.6K PENDENT(1/2"NPT) TY323 4 POLYESTER 175 175°F(79°C) *Use suffix"I"for ISO 7-1 connection; 9 CHROME PLATED 200 200°F(93°C) for example,77-370-4-175-I **Eastern Hemisphere sales only 286 286°F(141°C) TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Ordering Warranty Procedure For warranty terms and conditions,visit Contact your local distributor for avail- www.tyco-fire.com. ability.When placing an order,indicate the full product name and Part Num- ber(P/N). Sprinkler Assemblies with NPT Thread Connections Specify:Series TY-FRB Upright or Pen- dent(specify)Sprinkler, SIN (specify), K=5.6,Quick Response,(specify)tem- perature rating, (specify) finish, P/N (specify,refer to Table A). Recessed Escutcheon Specify:Style 15 Recessed Escutcheon with(specify`)finish, P/N(specify") Specify: Style 20 Recessed Escutch- eon with(specify`)finish,P/N(specify') *Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 • GLOBAL HEADQUARTERS I 1400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 Copyright©2014 Tyco Fire Products,LP. All rights reserved. ti co TEFLON is trademark of The DuPont Corporation. Fire Protection Products Eddythread 40 A Lightweight Schedule 40 Replacement Pipe That Has a Corrosion Resistance Ratio of 1.0 Bull Moose Tube Company has been making pipe for a long time and is recognized as a producer of quality pipe products. Eddythread 40 is designed with the same thoroughness as our other fine pipe products and now our customers have an option to buy a carefully designed replacement for Schedule 40 that: • Has a Corrosion Resistance Ratio of 1.0 • Has a Pressure Rating of 300 psi • Is Lighter Weight Than Schedule 40 • Is Approved by Factory Mutual and Listed by Underwriters Laboratories • Is Produced in Accordance to ASTM A-135 and A-795 • Can be Used With Standard Schedule 40 Threaded Fittings, Couplings and Valves • Is Produced From Steel With Excellent Properties of Strength and Threadability • Can be Used in Wet, Dry, Preaction, and Deluge Type Sprinkler Systems* • Offers Lower Freight Costs EDDYTHREAD 40 SPECIFICATIONS ''/MOMINAL.PIPE SIZEfini . WEIGHT(lbs/ft) , on): BUNDLE 81,4E 1 1.461 1.083 70 1 1/4 2.070 1.418 51 1 1/2 2.547 1.654 44 2 3.308 2.123 30 CORROSION RESISTANCE RATIOS Asx NOMINAL pIPE SCHEDULE EDDYTHREAD 40 1 1.00 1.00 1 1/4 1.00 1.00 1 1/2 1.00 1.00 2 1.00 1.00 *Eddythread 40 can be hot dipped galvanized to meet FM's requirement for dry systems 1819 Clarkson Road For additional information, Chesterfield,MO 63017 contact your salesperson today at c @us Atqlti r Bu"Mph TuBE cpMprgNY (800)325-4467 (800)325-4467 or(636)537-2600 L TEo ---"'- CJ FAX:(636)537-2645 in the USA,or from Canada www.bullmoosetube.com call(800)882-4666 411> • A CAPRRO company e-mail:salesrcf bullmoosetube.com APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 8/08 g� „' Duct' e ron i<ttings- ass I I 1 ' QUATII7 PLUS'. c ® US APPROVED Fig. 35E 3-90°Elbow LISTED Agill Size A Packing Weight I in Part Number in Inner Master lb ___� 1/235E30041.13100 200 0.2 3/4 35E 3006 1.31 70 140' 0.3 A 1 35E 3010 1.50 40 80 0.5 Ips, 1-1/4 35E 3012 1.75 25 `50 0.8 1-1/2 35E 3014 1.94 18 36 1.1 2 • 35E 3020 2.25 10 20 1.8 2-1/2 35E 3024 2.70 4 8 3.2 Fig. 35RE3-90°Reducing Elbow IIIB Size A B Packing Weight < > Part Number in` in in Inner Master lb II \ 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3 1 x 1/2 5RE3010004 1.28 ; . i , 1 ucti e ron fittings- ass I I I _ Q Aura c ® us APPROVED A Fig. 35CP3 -Straight Coupling with Ribs LISTED Size0 - - A Packing Weight in Part Number in Inner Master lb 1/2 35CP3004 1.38 200 400 0.1 3/4 35CP3006 1.63 100 200 0.2 ''"' 1 35CP3010 1.75 60 120 0.4 "1=1/4 35CP3012 2.00 35 70 0.5 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62 15 30 1.2 2-1/2 35CP3024 3.00 9 18 2.2 Fig. 35RC3 -Hex Reducing Coupling 11111 Size A Packing Weight in Part Number in Inner Master lb ® A 1 x 1/2 35RC3010004 1.69 80 160 0.3 1,x3/4„. 35RC3010006 1.69 60 120 0.4 1-1/4 x 3/4 35RC3012006 2.06 40 80 0.6 2 x 1 (not hex) 35RC302001.0`Ti ' 2.81 7.'1'00< 40 1.0 Fig. 35HB3 -Hex Bushing SizePart Number` A <. Packing Weight in in r�.: Inner Master,- "< lb. B 1 x 1/2 35HB3010004 1.06 180 360 0.2 Iii A x 3/4 ;" 35HB3010006, 110„0„7,'` 180 360 r�` QA„f.-,,, 1 1/4 x 1 35HB3012010 1 19 90 180 0.2 • 1-1/2 x 1 " 35HB3014010-; 1:25::' 75 150 0.4 1 1/2 x 1-1/4 35HB3014012 1.25 75 150 0.3 fo el 2 x1 35003030010 1.38 40 80 -.„ 0.6 2 x 1-1/4 351-03020012 1.38 40 80 0.6 2 x 1-1/2., 35H3 0014 1.38 40 80 0.6 4. Fig. 35SP3 -Square Head Plug .k Size APacking Weight in Part Number in , Inner Master Ib ,. 4~' 1/2 35SP3004 0.94 600 1200 0.07 i IR i' 3/4 35303006 ;. 1'13. ' 350 i7000 0:‘..1 IA 1 35SP3010 1 25 200 400 0 1 � 1-114 35SP3012 .1 7 , , „ 100 200 .*„..7,'.;,,„ 0.3. ,,, 1-1/2 35SP3014 1.44 80 160 0.4 2r. 35SP3020 l';"':"146 4f 1>; 45x: 90 <:,_ 0:e141':: Fig. 35U 3-Union with Brass Seat A Size '.4' A Packing ;. Weight s ,ink `cart Number in Inner Master;=u lb _.,'° 1 35U 3010 2.19 20 40 1.0 1-1/4 35U 3013 x 2.50'a;,r 15,: 30 ,.._' 1.2 - - 1-1/2 35U 3014 2.62 10 20 1.7 ® 1151 ;;:2 35U 3020 , 3.12 6 12 , 2.4 hug 113 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • wwwsmithcooper.com � .. �� .. ...., r v q V.*» $ Coos FM V S LPCB - , is 3A ':-w�•�4 a.` :3 1157Ep • 491a/27 SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating 1l h,3/4,and 1"/15,20 and 25mm outlets for directly connecting sprinklers,drop nipples,sprigs,gauges,drains and other outlet products.Available for 11/4 through 76.1 mm/32 to 76.1 mm piping systems,Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe.When tightened,the assembly compresses the gasket onto the OD of the pipe.The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068 kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard,lightwall,Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536,grade 65-45-12. Ductile iron conforming to ASTM A-395,grade 65-45-15, is available upon special request. Gasket: • Grade"E"EPDM-Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc.and Approved by Factory Mutual Research for wet and dry(oil free air)sprinkler services up to the rated working pressure using the Grade"E"Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: • Orange enamel(North America, Latin America,Asia Pacific) • Red enamel(Europe) JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. •ctaul-G REV G 10.52 1 IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 Fire' iIle STYLE 922 DIMENSIONS Nominal Size Hole Approx. inches/mm Diameter Dimensions-inches/millimeters Weight Each IrPTt Ya X Yz 3/16 Z-11.30 1.83 1.10 3.87 2.56 1.0 V 15 30.2 33.0 465 27.9 98.3 65.0 0.45 3/a 13/16 1.28 1.83 110 3.87 2.56 1.1 e 20 30.2 32.5 46.5 27.9 98.3 65.0 0.50 . �:r Wlia1 13/16 1.52 2.18 1.10 3.87 2.56 1.2 1 I 1 I 25 30.2 38.6 55.4 27.9 98.3 65.0 0.54 1'h 'h 13/16 1.42 195 1.22 4.08 2.56 1.2 40 X 15 30.2 36.1 49.5 31.0 103.6 65.0 0.54 1 3/16 1.40 1.95 1.22 4.08 2.56 1.2 23/410 ! 30.2 35.6 49.5 31.0 103.6 650 0.54 13/16 1.64 2.30 1.22 4.08 2.56 1.3 25 30.2 41.7 58.4 31.0 103.6 65.0 0.59 2 k 3/16 1.66 2.19 1.46 4.60 2.56 1.3 50 X 15 30.2 42.2 55.6 37.1 116.8 65.0 0.59 3/a 13/16 1.64 2.19 1.46 4.60 2.56 1.4 20 30.2 41.7 55.6 37.1 116.8 65.0 0.64 1 1 3/16 1.88 2.54 1.46 4.60 2.56 1.5 25 30.2 47.8 64.5 37.1 116.8 65.0 0.68 2'/ 1 13/16 1.91 2.44 1.71 5.40 2.56 1.6 65 X 15 30.2 48.5 62.0 43.4 137.2 65.0 0.73 3/4 13/16 1.89 2.44 1.71 5.40 2.56 1.6 20 30.2 48.0 62.0 43.4 137.2 65.0 0.73 1 13/16 2.13 2.79 1.71 5.40 2.56 1.6 25 I 30.2 54/ 70.9 43.4 137.2 65.0 0.73 76.1 mm X Y2 13/16 1.91 2.44 ! 1.71 5.50 2.56 1.6 15 30.2 48.5 62.0 43.4 139.7 65.0 0.73 3/a 13/161.89 2.44 1.71 5.50 2.56 1.6 20 30.2 48.0 62.0 I 43.4 139.7 65.0 0.73 1 13/16 2.13 2.79 1.71 5.50 2.56 1.7 25 30.2 54.1 70.9 43.4 139.7 65.0 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT(optional) male pipe threads only.Use of male threaded products with special features,such as probes,dry pen- dent sprinklers,etc.,should be verified as suitable for use with this Victaulic product.Failure to verify suitability in advance may result in assembly problems or leakage. *Center of run to engaged pipe end for NPT threads(dimensions are approximate). www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. /CtelUiod 10.52 2 REV G IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 HriA„ock- STYLE 922 PERFORMANCE Equivalent Length of 1 inch Schedule 40 Steel Pipe(per UL Run Size z Outlet Size 213,Section6)(C=120r,FT TIII- . trtf —** 11/4 x 1 8.5 32 25 2.6 1½ x 1 8.5 40 25 2.6 2 X 1 8.5 50 25 2.6 21/2 x 1 8.5 65 25 2.6 76.1 mm X 215 8.5 2.6 *Hazen-Williams coefficient of friction is 120 • www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.CO 2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. jctaulic° REV G 10.52 3 STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 10.52 3355 REV G UPDATED 12/2009 jctaullie VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. �--�--^--^'-'�• 10.52 Pipe Hangers Fig.200- "Trimline" Adjustable Band Hanger (B-Line Fig.B317ONF) ®TDLco Fig.200F- "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig.B317ONFF) c 0 us Fig.200C- "Trimline"Adjustable Band Hanger with Plastic Coated (B-Line Fig.B317ONFC) Us1ED Fig.200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig.200 - 1/2" (15mm)thru 8" (200mm)pipe Material: Steel, Pre-Galvanized to G90 specifications arb Function: For fire sprinkler and other general piping purposes. Knurled -- u swivel nut design permits hanger adjustment after installation. 81 Features: U _- - • (1/2" (15mm)thru 2" (50mm)) Flared edges ease installation for all pipe _ �,`�'',� types and protect CPVC plastic pipe from abrasion. Captured design ! / 1 keeps adjusting nut from separating with hanger. Hanger is easily h B " installed around pipe. A For hanger with non-captured nut order Fig. 200S. ;, h, • (21/2" (65mm)thru 8" (2o0mm)) Spring tension on nut holds it securely in - ,, - � hanger before installation.Adjusting nut is easily removed. (,,,;' Approvals: Underwriters Laboratories listed (1/2" (15mm)thru 8" (20omm)) Fig.200-1/2.2003/4 in the USA(UL)and Canada (cUL)for steel and CPVC plastic pipe and t Factory Mutual Engineering Approved(FM) (3/4" (20mm)thru 8" (200mm)). Fig.2007ta200-2 Fig.2002/z to 200-8 Conforms to Federal Specifications WW-H-171 E&A-A-1192A,Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 &SP-58, ,0. Type 10. •_ .. Maximum Temperature: 650°F(343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts µ in place of a knurl nut. `r � ,-/ , , Order By: Figure number and pipe size - Designed to meet or exceed requirements of �> `-,. FM DS 2-0. 'x • fi. Fig.200 Fig.200C Fig.200F Pipe Size Rod Size A B Approx.Wt./100 Part No. in. (mm) in. (mm) in. (mm) lbs. (kg) '- 200-1/2 1/2" 115) 3/8"-16 31/8" (79.4) 25/8" 166.7) 11 15.01 200-3/4 3/4' 120) 3/8"-16 31/8" (79.4) 21/2" 163.5) 11 (5.0) f,, 200-1 1" 125) 3/a"-16 33/a" (85.7) 25/4" (66.7) 12 (5.5) ,,. ft 200-11/4 11/4" 132) 3/8"-16 33/4' (94.0) 27/8" (73.0) 13 (5.9) 200-11/2 11/2" 140) 3/8"-16 37/8" (98.4) 27/8" (73.0) 14 (6.4) 200-2 2" (50) 3/a"-16 41/2" (114.3) 3" 176.3) 15 (6.9) . 200-21/2 21/2" 165) 3/8"-16 55/8" (142.9) 41/8" (104.7) 27 (12.3) 200-3 3" (75) 3/8"-16 57/8" (149.1) 4" (101.6) 29 (13.3) Fig.200S 200-31/2 31/2" (90) 3/8"-16 73/8" (187.3) 51/4" (133.3) 34 115.6) 200-4 4" (100) 3/8"-16 73/a" (187.3) 5" (127.0) 35 (16.0) 200-5 5" (1251 1/2"-13 91/8" (231.8) 61/4" 1158.7) 66 (30.21 200-6 6" (1501 1/2"-13 101/8" (257.2) 63/4" (171.4) 73 (33.4) 200-8 8" 1200) 1/2"-13 131/8" (333.4) 83/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line Protection Solutions 21 by EST*M Threaded Accessories B3205 -Threaded Rod (right-hand threads - both ends) (TOLCO Fig.103) /-''\2" . B3205L- Threaded Rod (right& left hand threads) / TL l� Size Range: 3/8"-16 thru 3"-4 rod Specify Length 1111' 1�1 Material: Steel Function: Recommended for use as a hanger support in hanger assemblies. - TL 1�11 Rod is threaded on both ends with right hand threads of the length shown.Also ��,�1A1�� A available with left and right hand threads-specify Fig.B3205L when ordering. Thread size Maximum Temperature: 750°F(399°C) Finish: Plain.Contact B-Line for alternative finishes and materials. Order By: Part number, rod size, length and finish Standard Design Load Thread Size Thread Length TL 650°F(343°C) 750°F(399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) B3205-3/8 X'L' 3/8"-16 21/2" (63.5) 730 (3.25) 572 (2.54) B3205-1/2 x'1' 1/2"-13 21/2" (63.5) 1350 (6.00) 1057 (4.70) B3205-5/8 x'L' 5/8"-11 21/2° (63.5) 2160 (9.61) 1692 (7.52) 83205-3/4 x'L' 3/4"-10 3" (76.2) 3230 (14.37) 2530 (11.25) B3205-7/8 x'L' 7/8"-9 31/2" (88.9) 4480 (1933) 3508 (15.60) B3205-1 x'L' 1"-8 4" (101.6) 5900 (26.24) 4620 (20.55) B3205-11/8 x11.' 11/8"-7 41/2" (114.3) 7450 (33.14) 5830 (25.93) B3205-11/4 X'L' 11/4"-7 5" (127.0) 9500 (42.25) 7440 (33.09) B3205-11/2 x'L' 11/2"-6 6" (152.4) 13800 (61.38) 10807 (48.07) B3205-13/4 x'1' ' 13/4"-5 7" (177.8) 18600 (82.73) 14566 (64.79) 83205-2 x'1' 2"-41/2 8" (203.2) 24600 (109.42) 19625 (87.29) • 03205-21/4 x'L' 21/4"-41/2 9" (228.6) 32300 (143.67) 25295 (112.51) B3205-21/2 x'L' 21/2"-4 10" (254.0) 39800 (177.03) 31169 (138.64) B3205-23/4 x'1' 23/4"-4 11" (279.4) 49400 (219.73) 38687 (172.08) B3205-3 X'L' 3"-4 12" (304.8) 60100 (267.32) 47066 (209.35) ATR- All Threaded Rod 120" (3.05m) Lengths (TOLCO Fig.100) Fig.99 -All Threaded Rod Cut To Length �,� �p ,1`glq' r �7,1;Vii,^llll�111�1��i111 Size Range: 3/8"-16 thru 11/2"-6 rod in 120"(3.05m)lengths or cut to lengthy�1���� ' Material: Steel )0) u) vd Maximum Temperature: 750°F(399°C) as a Finish: Plain.Contact B-Line for alternative finishes and materials. s u Order By: Part number, rod diameter and finish 1-q Part No.-Size x Length Threads Recommended Load Approx.WtJ100 Ft. ATR Fig.99 Per Inch Lbs. (kN) Lbs. (kg) AIR 1/4"x 120 99-1/4"x length, 20 240 (1.07) 12 (5.44) ATR 3/8"x 120`` 99-3/8"x length'' 16 730 (3.24) 29 (13.15) ATR 1/2"X 120 99-1/2"x length, 13 1350 (6.00) 53 (24.04) ATR 8/a"x 120 99-5/8"x length 11 2160 (9.60) 89 (4037) ATR 3/4"x 120 99-3/4"x length " 10 3230 (1437) 123 (55.79) 'ATR 7/a"x120 11100a=119 4480 (1933) 170 (77.11) ATR 1"x 120 , 99-1"x length 8 5900 (26.24) 225 (102.06) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. Pipe Hangers&Supports Revised 4/28/2014 by Line 236 by FaAN VERTICAL MOUNT SAMMYS" SAMMYS° for Wood Not less than Wood Flooring 2"nominal width Product Features (1-v2") 1— •No pre-drilling required. INot less than •Quick to install using the Sammy a °. 3"nominal thickness(2-1/2") /`u Nut Driver with an 18V cordless (depth or side wood Joist drill/driver. of vertical member) -- i _ W •Saves time from traditional Double Sheetrock methods. i3 For vertical use- Ceiling ,' 3 install in center of louver face. •Reduces installation cost. Mnimum 2"embedment into base material for NFPA 13 compliance. Composite t Truss •Made in the U.S.A. Consult truss manufachrer for 1 recommended instillation point ~ "Pre-di/Mg maybe required for GST 25.380.Tool eyelet/on page 10. i Approvals Rod Part t Screw Ultimate UL Test' FM Test Box dose A pp ode Size Number Descriptions Pullout(lbs). Load(lbs) Load(lbs) Qty Qty _ :210(7/16°0S6) S { 1/4" 8002957 GST 100 1/4 x 1' 670(3/4'Ply) 25 125; 1/4" 8003957 GST 200 1/4 x 2" 1760(Fir) 25 125 1/4" 8004957 GST 300 1/4 x 3" 2060(Fir) ''.17.,:;. 25 : 125 m ,, 3/8" 8006957 GST.75 1/4 x 3/4" 564 (3/4"Ply) 25 125 ik 3/8" 8007957 GST 10 1/4 x 1" 210(7116 OSB) n,' 300 25 125 , ,_ 870(3/4"Ply)1:.:. ' 0 3/8" 8008957 GST 20 1/4 x 2" 1760(Fir) 850 1475 25 125 r; 3/8" 8068925 GST 20-SS 1/4x2" 1760(Fir),„ 850 25 125 g- 3/8” 8009925 GST 25-380 3/8x2-i/2" 2113 (Fir) 1500 25 125 #14 Black d 3/8" 8010957 GST 36'.'!„' 1/4x3" 2060(Fir) 1500 "'': 1475 25 ,<. 125 Nut Driver 3/8" 8069925 GST 30-SS 1/4 x 3" 2060(Fir) 25 125 Part#8113910 3/8" 8011925 GST44 .:-; 1/4x4" 2180(Fir) `' 25 125'>s 3/8" 8012925 GST 60 1/4 x 6" 2230(Fir) 25 125 1/2" 8013925 GST.2..„,'•,,,,,:;:,,,. , 1/4x2" 1760(Fir) „.r, 25 125 1. .- ,„ 1/2' 8014925 GST .5-380 3/8 x 2-1/2" 2113(Fir) 25 125 1/2" ", 8015925 '� GST 3 1/4x3" 2275(Fir) 25 :,125 , — :.s 1/2" 8016925 GST4 1/4x4" 2180(Fir) 25 125 ,,4/2," 1- 8017925 GST,57: 114x6" 2230(Fir) r". 25 r. 125,x:'', #14 SW Red Nut Driver Part#8114910 ' SAMMY Swivel Head° for Wood Product Features •Eliminates distortion of threaded rod. •Saves time from traditional methods. •Accommodates up to 3%:"x 12 pitch roof. •Reduces installation cost. •Allows 17°deflect on from vertical. •Made in the U.S.A. i + Rod Part Screw Ultimate Ut.Test FM Test Min Box Case yam- Approvals Model < Size Number Descriptions Pullout Obs) Load(lbs) Load(lbs) Thickness Qty Qty +^ 3B" 8139957 SH GST 20 1/4 x 2" 1257 1050 1475 25 125 125 '#14 i 1 3/8" 8141957 SH-GST30 1/4x 1720(Fr) 1500 1475 25 125 Black Nut Driver *) SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into Part#8113910 contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. For the most up to date information visit www.sammysuperscrew.corn 4 '4, re