Plans (44) 7 a Markup Legend SPRINKLER SYMBOL DEFINITION COLOR/LINETYPE LEGEND LL-P: BLUE LINES= FEED TO FIXTURES(BATH,SHOWER,ETC.). o Delete Line XXX XX GREEN LINES= INTERLEVEL CONNECTIONS/SUPPLY. J u MAXIMUM SPACING(TYP) BLACK LINES=SPRINKLER HEAD TO SPRINKLER HEAD. O e o Add Line SPRINKLER MODEL(TYP) - = 1/Z"PIPE SIZE C ,y�°E HEAD SYMBOL(TYP) >. . =3/4"PIPE SIZE a N w a a ^GO -I- = 1"PIPE SIZE Add Tee E--,' - = 1-1/4"PIPE SIZE w''.1 w o Add Elbow CITY$.' O F 'T I G A R D a f w,o u'o 1 I 191 y l-1 I L/ z a I / WL^�� Add Coupling I I Approved ['' .1 = .,3 0.�aw� p [ i RECEIVED �esiaW Add Head COIICIItI011llly Approved oS'F.L3 See Letter to: Follow [ 1 Delete Head -0 Attached �[ ] JAN 2 3 2017 ‘,,•'.' zw owxo w¢ r<.o zoo of Move Head -O- -0- Permit Number: 7y�rl 0l(]', �`) 8o�`- 2=t2 CITY 01=TIGARD 26=° ,�ow.s,.z Address: 1C°?S.S,WI, aecvIo.:'(s�i3 -j-c l',. (.. BUILDING DIVISION ---6..2. ,,,,,n-..° w molt_< Note:All revisions must be reviewed by Uponor r�-� -- ::�tus ill , ,9,-,--.,.P,,7,,„,---,w g F z S z o 3 o Table F002-1 By: u Date: �) 2,2,-;,4- _,,,,,:1,,;,z,o>?U } `n a Multipurpose Fire Safety Systems a o The Uponor Residential Fire Safety System is a residential fire protections E z z< e o _-' system installed in combination with the cold side of the domestic potable d'm v o o¢LL o o z water system. Only licensed contractors trained by Uponor can install this W o a�, _' z<3 o E E o w r system. Q 6E,E.s,.o 7.,. =. What to do if Changes are Required `zz: amu-1� J za No_z¢wp'2,Eo If any features or obstructions require the addition or deletion of sprinkler 1"AQUAPEX INTERLEVEL 1"AQUAPEX INTERLEVEL E- o F o->z o u h W heads,or significant relocation of sprinkler heads,contact the Uponor Design d E n-<2 Z o z m u 9 P P 9 CONNECTIONS FROM SECOND CONNECTIONS FROM FIRST D o - < z Department to determine if observed changes require a redesign z w o z '- �> F P9 9 FLOOR TO THIRD FLOOR FLOOR TO SECOND FLOOR ¢w-�K.x o w (888.594.7726). / Fzoz�Nw'o«zo MOST HYDRAULICALLY REMOTE HEADS // \\\ /1 \\\ ,.,-a< o!>o. `o, HEAD# GPM PRESSURE REQ'D AT STREET E i / /_1 c��w.'9 � }8 1 HEAD H.8 10 35.58 P \ \�' i o ft 'Z2< I I L Poo <xo x 7 _ 2 HEAD H.1&H.4 20.0269 47.35ii ;12-E---11-1:1,,..„ ,', / I i �� wd.x >- G2U w rn>F-> x O U i K �/ - -RH.2 14 \ r z. a w 1/ \ IARC RESLF 14 I \ H.3 H.2/ A v in ���� r� I �t Floor _ / \ ® �� A/ \ � V' 1Bedroom}\/ iJ �w'1 j�j'1To �7�$''','';,��� COPY 18 TOTAL / 1 \ T , _\ _ - O` 1 ACL 1� RECF 14� / ,71' \ { ,n SENJU Model RC-RESLF37 Low Flow K3.7 Residential Concealed Pendent SS8261 / \\ I VIII I L SIL nlad 0 - - - 18 K=3.7,162F°,7/16"Orifice,Maximum Spacing 14'x14' �� / / il \ _ Lli \ I11 j I RC-RESLF-14 Sprinkler head demand: 10 gpm @ 7.3 �� -II IT �iIMI C-iw ,_ .21 a , j A. -IF- 1 "AquaPEX TO SYSTEM .19 \ T.24 ---r; \ n \ i / \ G S.1 MAIN SHUTOFF r s ,I ,.� III I - �, = i; VALVE LOCATION TZQ z �2 /1 r` \ H.�©1 / 'CRE LF51a \ `'■ T431 �r�wq I�I�) C / 1 r \ I RC-RESLF.-14 T.25 mi ,f I \ \ ` II 1012-1L-41 W�«<,4k S /� \!'11 F.8 i T.2f I.F., I \ \ Mecf ;11 o 11 - °/ , u7 e____� \ 1A A IF TEES d z m.i of r \ \,..' f L 1C - r`T/ 4tg i' F S O o d GEL \ J A , ,1 , F7-'.`'76' M. B th_ , ,/1 { - / T. 61-r I �7 2 F.1 - '���i w ; ii 06. RC/HATSVF k'4 , ` 1, I / J "� : j��iE IIH 1 H IIII o o m ii _ /Fic,..... tF,r- - 13�'' - k ;I ✓ .1.' 7 - 1' r.... 11 " k K v�O o ri �..i LET, t'-'''''',•,,W4,. � 1 ci 3 '� \,,, C l� � 0 f�a J 4 T181 l w �, -T;32 _ EXTERIOR WALL / 1• I' F.3 H.12 T 34 �11 1 u Ilse Y i R ..er er 2 �; i '� < 1--- aaUzo°' LI / ELEV=108' al.N,,.,u R 1 e� RC-iAWf 84 11 - f 7 �F 1 STATIC: 60psi , � _, T.3« r.. Isl1 T,4� �' P aM Z.z a o w m 06 RESIDUAL: SSpsi !Lir ❑Ir` < �. i�' y FLOW RATE: 3650gpm h`F nu H.13 p Evr` I 7 �� ,--, N1 o 0 0 = o En _/ s; '-� ` uu ua amzo 1-1/4"AquaPEX lvk s,eqv. I 11 - '.L. Irl _ /H 15 .P J i L.L. D N > o % \TOSYSTEM HOT WATER HEATER RC-rt 1111- iF�+.L.„,_,,,__I, it 111 'RC-Ft:NV 14^ rlL, Q Ill w s.l '1 R�� .1 00 Y % ELEV 104 111 5 H U �� 1 1 FI.1 8+ s __ cLO \. � / F"1 S 4 ,'/ V O w 0 �� p �1 1/4"FULL PORT r �A4 1 i Z m a N a LI RRESLF 14 C RE F / BALL VALVE 4 (14r_4,_1, P rcr rlier�// L_ �H j°y I � j 1L- w rn>w t ' / li. 5 1 Q i , � E r / - 7� - r 'FFTY i Wr H W =m F / ,;IS-r z o G ELEV=100' ELEV=100' / ce CO 1--I G z Y S F ///////////1 ~ �ouE3 6 5/8"METER 3 THIRD FLOOR SECOND FLOOR 1 FIRST FLOOR F 35'OF 60'OF I r SHEET DESCRIPTION v 1"COPPER-K 1-1/2"AquaPEX F100/ 1/4" = F10�% = I II F100 ALL LEVELS _� 11-0" 1/4" 1 -0 1/4" = 1'-0" WATER SERVICE DETAIL 5 _ 5 15 SHEET NUMBER 4 Y� E F100/' NTS 1/4"=1'-0" © UPONOR - CONFIDENTIAL Markup• Legend • SPRINKLER SYMBOL DEFINITION r .. 1 COLOR/LINE-TYPE LEGEND 8 XXX-XX a ' BLUE LINES=FEED TO FIXTURES(BATH,SHOWER,ETC.). o Delete Line } 1 I 4 GREEN LINES=INTERLEVEL CONNECTIONS/SUPPLY. i u MAXIMUM SPACING(TYP) -_ (— t- BLACK LINES=SPRINKLER HEAD TO SPRINKLER HEAD. O o :::: ��j //// i,.' = 1"PIPE SIZE a cr u W� ��� H� , = 1-1/4"PIPE SIZE O 2!.1,,,,„2 Add Elbow �� .:117/1: "w o 2 ry a d j r. mm1.�?� W Add Coupling j / I Z m o nrvmaw Add Head A 1\ A2\ A.3 - i- O,r°'i w t i Delete Head -(X)- ( 1 � " i / //// rI oy Ii ! II �.1Ir 11 y ma Note:All revisions must be reviewed byU onor k... r - ff ' E w m 'T'1','-:.`F±8 P � J � I� ¢❑ o ¢ ❑c^zd F. Table F002-1 — - L�_-_ — ¢ °:.'�... -'z 0 s¢ Multipurpose Fire Safety Systems ¢ 000 . The Uponor Residential Fire Safety System is a residential fire protections o 0 0 n z,z o J _F' system installed m combination with the cold side of the domestic potable �1 0' c i o¢=' >¢¢ water system. Only licensed contractors trained by Uponor can install this 4 KEY PLAN uJ o,_, ,..,...._.,,n,,,,,_,xz system _� "-I¢= z~z< a 3`; F101; �2I�°so°,anFeno What to do if Changes are Required NTS UI zz- <>.cy4 If any features or obstructions require the addition or deletion of sprinkler fA z -C.-5M75>-.5u.,-E.-_, heads,or significant relocation of spookier heads,contact the Uponor Design C m 2 z?s¢F z o s�'= Department to determine 4 observed changes require aredesign - - j 1"A UAPEX INTERLEVEL ' <=x - w w z'' =v (888.594.7726). 4 V,., y-_- hy,^, Q '� _ INTERLEVEL i-" - xiF- ,1, - ,,z:. ¢, =o 888.594.7726. 1 r CONNECTIONS FROM SECOND ( J ,�,C� L •L' CONNECTIONS FROM FIRST j `=Q d �+ yo 0 FLOOR TO THIRD FLOOR 1 t FLOOR TO SECOND FLOOR "- v " c z F RESL ,, �� ,7 �n c// / \A r - " L�' / ' A �.'., 8-u 1- 11 = �> m °i�cxa` H.? / \ \ RC ESLF 14 ' r / :1,L_ ,-,,,,' — � � �A RC RESLF 14 VA 1 F zz opo "fedroor �j / 44I! \ \f _x o / IILry TI / _ �L RC-RESLF � / G� \F f \ I / \ \ \ �I 1� — IFE L,Uc \ LL AFL t _ 21 �> ,� 1�1 'r 11 T.1 V20-ELN1 FA / fC E I1F14- / / � I y. l' 1 CS.1 MAIN SHUTOFFION _ a"I, I� / T.25� F 14 / ( o Mi v21 J' VALVE' goa EXTTO SYSTEM 0 I II RC S 1 '11.27_1:' / T.26 '- r-F71'.8-R..j6ESI- q ech f / hs-Mil ill 1 _ .r. -, , ,...,,,R A_0,,,.,,,, ,_,„ , 14 1 11 'ID SL 214= / 3iR�M. Bath & °` °`r. b \ N12�91'I '� \ oli� SLE44 I% .9 / - = . \5 1,1 w I wzH.11 , 4 ,w E1 ,, � ,, 2 °���a1 1 F.LL '1 9`1 T.31 T: 3` T 34 H.1211\` x 3�'f_ — ,1 -, w W _f SLF44 G�� F.3 I Ln e. Lrr.l T:3 R 14III _ ti t, 111 i' a <�%. ‘-','ENT .3811 ll� _ - L a \� r Y 'u u a a RSL1 + , SII TAO 141% QOM =<J�w g r' H.13 I - "-± ill � I „ r � a3 , OMzc� ggsa°,=o F • �i h �o, .,,P N o Ii a ' ( ,,fl \ L 0 I ,� � c l � I I y 16 >_ II 14 ER,,•!, III LJ,J o� iii 1 .I 118 I— °t) C7 O RR HAS �� V SLF 1 RC RE �4 \ ' (- 1 . o I a� 111 ,\,ITCH 6:12 ? -- Fh DYE 3 ,,,.III Z m¢,ry 0 PI c" r r 1 I ;7 rvj 13 ill 612 6;12 1 4 1 1 219 X11 � 5---_—,_:::-_,(1,..,_ W 0 ..w''m� 7. , }i_ 1 i 1 , I `�_, i nn t r_ � Fxi E REIN / i--i Q m ..`,3•:-' �� Q o ..S z b r �J 1 L rx� ;' ��./�� \./ z Y o Ce W G z uc H i L, F='"K EE c U El r g Z 3 THIRD FLOOR-MIRROR 2 SECOND FLOOR-MIRROR 1 FIRST FLOOR-MIRROR SHEET DESCRIPTION t n F101 _ ii F101 ALL LEVELS MIRROR F1o1," 1/4" 1 -0 1/4" 1 -0 1/4" = 1'-O" 6 SHEET NUMBER 0 5 0 5 1s © UPONOR - CONFIDENTIAL F101 F- Senju RC-RES:Open Web Truss/TJI Construction Insulation Recommendations AquaSAFETM GENERAL NOTES: In areas subject to freezing,care should be taken in unheated attic spaces See General Notes 8.2.5.7 for Architectural ProPEX LF Brass Fire to cover Uponor AquaPEX tubing completely with insulation. Insulation Feature Requirements '^ Sprinkler Adapter Tee Z should follow the guidelines of the insulation manufacturer. See Uponor z 1. THIS SYSTEM IS DESIGNED AS PER NFPA 13D 2016 EDITION AS A RESIDENTIAL MULTIPURPOSE SYSTEM BlockingMaybe Fire Sprinkler Adapter g f SECTION 3.3.11.3. Y - - _ Document'Uponor AquaSAFE Attic Insulation Guidlines"for attic \ O 0 Required.If �� _ Push-on Nut installation guidelines(Provided in Contractors Documents package or online > u 2. UPONOR COMPANY RESERVES THE EXCLUSIVE RIGHTS TO ALL DETAILS AND DRAWINGS AS SHOWN ON Blocking is Used, -�-, • 1%q"Min. at www.Uponorpro.com). 5 o Use The 2 Top I I I THIS SHEET. THESE DETAILS AND DRAWINGS ARE PROPRIETARY INFORMATION OF UPONOR COMPANY AND 1 3'"Max. >n p Screw Holes. J Planter Box Window,Ba Window or Similar Feature. UNAUTHORIZED USE MAY BE SUBJECT TO PROSECUTION TO THE FULL EXTENT OF THE LAW. 4D- E / Bottom of Mounting Extreme Temperature Installations Y C a o Bracket to Face of Truss If no additinal floor area is created No Additional Sprinkler is Required. ^G u AquaSAFE Residential Fire Safety systems are often installed in attics or a W Q 3. THE DESIGN OF THIS SYSTEM IS DICTATED BY SPECIFIC CEILING HEIGHTS AND ROOM SIZES. IT IS THE Fire Sprinkler Adapter- - 7 other areas exposed to temperature extremes of heat and/or cold. Followm RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO ENSURE THAT THE CONDITIONS SHOWN ON THESE p p p p / 8'-0"or less O N ry u 0 Mounting Bracket the recommended extreme weather installation instructions to isolate and / u'> PLANS ARE EXACTLY AS THEY EXIST IN THE FIELD. DEVIATIONS FROM THE DESIGN MAY CAUSE THE w 3 LL w SYSTEM TO BE UNABLE TO CONTROL A FIRE.IF THE BUILDING CONSTRUCTION DIFFERS FROM THE FIRE protect system components from extreme temperatures. Because this RC-RES-16 O system also delivers domestic cold water directly to plumbing fixtures, ® \ .w.w u p SPRINKLER PLAN,CONTACT THE SYSTEM DESIGNER IMMEDIATELY. 3-#10 x 1 1/2" - 9'-0"or less Q >T. z a �_r } Uponor highly recommends that you protect the tubing with adequate / 4' y m^0 4. THIS SYSTEM AND THE ACCOMPANYING HYDRAULIC CALCULATIONS ARE DESIGNED IN COMPLIANCE WITH ThreadFull uSr yews 'L7 I ll� i insulation in warm weather areas to minimize heating of the cold water N\ y s,v w NFPA 13D 2016 EDITION. supply. - 0 a 74 i a In Button-Holes - o v 5. "STAND-ALONE"OR"MULTIPURPOSE,WET PIPE"SYSTEMS ARE NOT PERMITTED TO USE ANTI-FREEZE. -\ -� Installation methods include,but are not limited to: o W rn m E w • Tenting over the fire sprinkler piping. O u,t• ?i 6. MODIFICATIONS ARE PROHIBITED.SPRINKLERS THAT HAVE BEEN PAINTED,CAULKED,MODIFIED OR Lead-Fre Flat y • Additional layers of batt insulation. If additional floor area is created.Cannot exceed 18 ft',be more than 2'-0" DAMAGED MUST BE REPLACED. Conceale�Senju Concealed Flat • Increased depth of blown-in insulation. deep,more than 9'-0"wide and be with in the coverage area of the o w Sprinkler Head Cover Plate sprinkler.No Additional Sprinkler is Required. 85 o Y z z F w¢ 7. WATER SHUT OFF VALVE IS NOT PERMITTED THAT ISOLATES THE SPRINKLER SYSTEM. Caution: If you will be installing spray foam insulation,make sure to U,> U¢"o z o o 0 �.0 - 8. OWNERS MANUAL MUST BE PROVIDED TO THE OWNER. Senju RC-RES:Traditional Wood Framing Construction Protect all components during application.Consult with the spray foam <.z.r o?o v,-m o c manufacturer to ensure compatibility with all products before application. NFPA 13D Table 7.5.5.3 Distances From z N 0 z r o z¢o`' 9. AT THE MAIN SHUT OFF VALVE,A TAG OR A SIGN STATING THE FOLLOWING IS REQUIRED;"WARNING,THE Heat Sources 9 r t z t,-.< 5 o Y 5 o WATER SYSTEM FOR THIS HOME SUPPLIES FIRE SPRINKLERS THAT REQUIRE CERTAIN FLOWS AND Consultation with local building officials is encouraged to ensure compliance F g w�, O z a�s C m o PRESSURES TO FIGHT A FIRE.DEVICES THAT RESTRICT THE FLOW OR DECREASE THE PRESSURE OR ProPEX LF Brass Fire with local building codes. 'g.2: `2 o �m„ o <u Ordinary Intermediate z o S u >.-'!'Z' !, 'Z AUTOMATICALLY SHUT OFF THE WATER TO THE FIRE SPRINKLER SYSTEM,SUCH AS WATER SOFTENERS, Sprinkler Adapter Tee Fire Sprinkler Adapter Heat Source Temp. Tem o d _�z FILTRATION SYSTEMS AND AUTOMATIC SHUT OFF VALVES,SHALL NOT BE ADDED TO THIS SYSTEM a a Push-on Nut P• r WITHOUT REVIEW OF THE FIRE SPRINKLER SYSTEM BY A FIRE PROTECTION SPECIALIST.DO NOT REMOVE I 135°-170° 175°-225° m a o 3 z o THIS SIGN". �I��I iI 0� Bending PEX Tubing Side of Fireplace 36" 12^ o z z a �a 1 t/q'Min. The minimum bend radius of Uponor PEX tubing in any direction is six times Front of Fireplace 60" 36" W o o e S <°2 z 3<o 10. ALL INTERIOR PIPING TO BE UPONOR"AquaPEX®"UNLESS NOTED. 1 14 Max. the outside diameter(6 x OD). 0 w 5=5 a z -.w Fire Sprin der Adapter Bottom cf Mounting Bend supports are available for 3/8",1/2",3/4"and 1"Uponor AquaPEX Wood Burning Stove 42" 12" N ¢o a d �,�, z o�_ Bracket to=ace of Truss ¢a=_Z Z Z s F- <>3"' 11. UPONOR"AquaPEX"TUBING TO BE SUPPORTED PER NFPA 13D AND MANUFACTURER'S RECOMMENDATIONS. Mounting Bracket J. / tubing to facilitate 90-degree rigid bends. Kitchen Range 18" 9" Q w z<o o o z< o o Lam/ J u7-9.0.-rt, Wall Oven 18" 9" u Le 25<5 aw-,r,< 12. MINIMUM SPACING BETWEEN SPRINKLERS IS 8'-0" REFER TO SPACING CHARTS FOR MAXIMUM SPACING 2-#10 x 1 1/2" O Recommended Tubing Length Between Fittings Hot Air Flues 18" 9" Uf z u o u `o o v z>u 1. BETWEEN SPRINKLERS AND FROM WALLS.SPRINKLER HEAD MANUFACTURERS MAY HAVE MORE Full Course £ �"'f w N a o- <o' o w- RESTRICTIVE SPACING LIMITATIONS. Thread Screws i I Fitting Size Minimum Tubing Length Unin5 laced Heat Ducts 18" 9" C m z o z_F z =>?- U 3 8"ProPEX FittingPipess 5_2 _S o°z N 13. SPRINKLERS ARE NOT NECESSARILY CENTERED IN ROOMS DUE TO LIGHT FIXTURES OR OTHER CEILING In TopHoles U / 2„ Si ie of Hotod Hot Water 24" 12" azo 5 F N o¢w o MOUNTED OBSTRUCTIONS. 3 5 z N z ❑ .- 1/2"ProPEX Fitting 2 1/2" Side of Air Diffuser 24" i¢w o o F= �'a o \ ��' Front of Hot Air Diffuser 36" 18" -g y w >> ,¢w¢ o z ¢ 14. THE PLUMBING TIE IN CONNECTIONS ARE SCHEMATIC IN NATURE AND CAN BE INSTALLED OFF THE 3/4"ProPEX Fitting 3 1/2" Hot Water Heater 6" 3" z z 0 ¢ c! w SPRINKLER LOOP ANYWHERE BETWEEN SPRINKLER TO SPRINKLER CONNECTION. Lead-Free Flat r - 5 o o 5 z o 5 o=_o 'y o Concealed SenJu \ L. Concealed Flat 1"ProPEX Fitting 4 1/2" Furnace o o z in Sprinkler Head 50W-250W Light Fixture 6" 3" 'r'4->< 8-''f'" ,°7,'¢ �w,Le a ww z_i z0' 15. THIS SUGGESTED LAYOUT IS BASED UPON INFORMATION PROVIDED BY OTHERS. CHANGES IN Cover Plate 1 1/4"ProPEX Fitting 5 1/2" 9 >5 ,„o-n THE RESPONCONSTRUCTIOIBILLITY OF THN OR FIELD E INSTALLER O NOTIFY UPONOR TECHNICALNDITIONS MAY OCCUR WHICH MAY SERVICES OFE CHANGES OTHE LAYOUT.SUCH CHANGEST IS 250W-499W Light Fixture 12" 6" w z 5 Y 5 5°w s s_ V -wr�oz¢o zmxw- w 16. NFPA 13D 8.2.5*OBSTRUCTIONS TO RESIDENTIAL SPRINKLERS Uponor A Exposed Installation a and Requirements. F -N <u u_s F o b¢ • 8.2.5.6* SHADOW AREAS SHALL BE PERMITTED IN THE PROTECTION AREA OF A SPRINKLER AS LONG AS Uponor Fittings tubing(white)and ProPEX'"EP Fittings and ProPEX'"' \ I S THE CUMULATIVE DRY AREAS DO NOT EXCEED 15 FT°PER SPRINKLER. Brass Fittings are approved for exposed installation where the following • 8.2.5.7 SMALL AREAS CREATED BY ARCHITECTURAL FEATURES,SUCH AS PLANTER BOX WINDOWS,BAY conditions are met.(UL 1821 Approved) WINDOWS,AND SIMILAR FEATURES,SHALL BE EVALUATED AS FOLLOWS: _ (1)WHERE NO ADDITIONAL FLOOR AREA IS CREATED BY THE ARCHITECTURAL FEATURE,NO Exposed Wood Joist Ceiling Assemblies, s 711 ADDITIONAL SPRINKLER PROTECTION IS REQUIRED. 1. Joists are of dimensional lumber,engineered wood,wood I-joist or open nio m (2)WHERE ADDITIONAL FLOOR AREA IS CREATED BY AN ARCHITECTURAL FEATURE,NO ADDITIONAL web wood joists. ///����' SPRINKLER PROTECTION IS REQUIRED,PROVIDED ALL OF THE FOLLOWING CONDITIONS ARE MET; 2. Joist are of depths from 6-16 inches(152-204 mm). (/ m (a)THE FLOOR AREA SHALL NOT EXCEED 18 FT"(1.7 M2) 3. Joist are of spacing from 12-24 inches(305-610 mm)on center. (b)THE FLOOR AREA SHALL NOT BE GREATER THAN 2 FT IN DEPTH AT THE DEEPEST POINT OF 4. Joists can be exposed after installation. \ I \ Q THE ARCHITECTURAL FEATURE TO THE PLANE OF THE PRIMARY WALL WHERE MEASURED 5. Metalpipe hangers spaced at maximum 24 inches(610 mm)on center 'I 1.55" / ALONG THE FINISHED FLOOR. 9 p 1.66" are used. (c)THE FLOOR SHALL NOT BE GREATER THAN 9FT IN LENGTH WHERE MEASURED ALONG THE 6. Listed residential automatic sprinklers of maximum activation to 3n Hanger 1�� Hanger E PLANE OF THE PRIMARY WALL. temperature rating of 155°F(68°C). 2 4 g g (d)MEASURED FROM THE DEEPEST POINT OF THE ARCHITECTURAL FEATURE TO THE SPRINKLER 5 SHALL NOT EXCEED THE MAXIMUM LISTED SPACING OF THE SPRINKLER. Tubing Support pacing: (3)THE HYDRAULIC DESIGN SHALL NOT BE REQUIRED TO CONSIDER THE AREA CREATED BY THE Metal Tubing Support. (Anchor AquaPEX PEX TubingSecurelyEnough to Q q 9 Support the Tubing,Yet Relaxed 1. Metal tubing supports designed for plastic tubing shall be used. ARCHITECTURAL FEATURE. Enough to Allow the Tubing to Expand and Contract) 2. Do not use supports that will damage the tubing.Inspect metal 17. NFPA 13D 8.3 LOCATION OF SPRINKLERS. supports for sharp edges. 1. Along Horizontal Runs,Install Supports Every 32",if Horizontal Runs are 3. Do not rigidly anchor Uponor AquaPEX"'tubing with supports.Allow y Supported,Place Tubing Supports at Six-Foot Intervals. • 8.3.1 SPRINKLERS SHALL BE INSTALLED IN ALL AREAS EXCEPT WHERE OMISSION IS PERMITTED BY 8.3.2 Continuous) Su enough tubing for freedom of movement to expand and contract. Along Supports Every Four to Five Feet,at Each THROUGH 8.3.8. 2. Vertical Runs,Install • 8.3.2 SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55 FT2(5.1 M2)AND LESS Floor and at a Mid-story Guide. 35 - 8.3.3 SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS,LINEN CLOSETS,AND PANTRIES THAT m z MEET ALL OF THE FOLLOWING CONDITIONS: In-line Flow Test z z o (1)THE AREA OF THE SPACE DOES NOT EXCEED 24 FT2(2.2 M2). The In-line Flow Test can be constructed on site. It performs a flow test to 5 0 m - (2)THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE Standard Riser Assembly ensure proper system operation and flow(see Figure F001-8). t`P MATERIALS AS DEFINED IN NFPA 220,STANDARD ON TYPES OF BUILDING CONSTRUCTION. u 0 In a safety purpose system a single control valve controls both domestic and °` '" 8.3.4* SPRINKLERS SHALL NOT BE REQUIRED IN GARAGES,OPEN ATTACHED PORCHES,CARPORTS,AND a w il 05 • fire safety needs. SIMILAR STRUCTURES J o o m p • 8.3.5 SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS WITH OR WITHOUT STORAGE,PENTHOUSE Uponor AquaPEX G .. EQUIPMENT ROOMS,ELEVATOR MACHINE ROOMS,CONCEALED SPACES DEDICATED EXCLUSIVELY TO AND Tubing j o CONTAINING ONLY DWELLING UNIT VENTILATION EQUIPMENT,FLOOR/CEILING SPACES,ELEVATOR SHAFTS, w m CRAWL SPACES,AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING j / W Ln s L.`° I z Q w z iO PURPOSES. m • 8..3.5..1.SUCH SPACES THAT CONTAIN FUEL-FIRED EQUIPMENT SHALL ALSO COMPLY WITH 8.3.5.1.1 OR j U V V¢vui u a •" 8 / C C • 8.3.5.1.1 WHERE THE FUEL-FIRED EQUIPMENT IS ABOVE ALL OF THE OCCUPIED AREAS OF THE DWELLING / __ -.4 GI F- M 5 z Q 0 - 0 UNIT,NO SPRINKLER PROTECTION SHALL BE REQUIRED IN THE CONCEALED SPACE. i aill o~w N ,3 • 8.3.5.1.2 WHERE FUEL-FIRED EQUIPMENT IS BELOW OR ON THE SAME LEVEL AS OCCUPIED AREAS OF THE I-1N O O o a 10 z o o' DWELLING UNIT,AT LEAST ONE QUICKRESPONSE INTERMEDIATE TEMPERATURE SPRINKLER SHALL BE Male Threaded Coupling-/ ProPEX Fire 7 0 INSTALLED ABOVE THE EQUIPMENT OR AT THE WALL SEPARATING THE SPACE WITH THE FUEL-FIRED Sprinkler Adapter Z N to EQUIPMENT FROM THE OCCUPIED SPACE. \_ Ce D N w 0 • 8.3.6 SPRINKLERS SHALL NOT BE REQUIRED IN COVERED,UNHEATED PROJECTIONS OF THE BUILDING AT -_ 1"Ball Valve Q -To Hot Water Heater Male Threaded Coupling al o ENTRANCES/EXITS AS LONG AS THE DWELLING UNIT HAS ANOTHER MEANS OF EGRESS. 13 -- _ H M�•./� w c • 8.3.7 SPRINKLERS SHALL NOT BE REQUIRED FOR CEILING POCKETS THAT MEET THE FOLLOWINGFemalee with Water W �/ 0 r • CONDITIONS: = a Tee Water L.f� u iv 'n (1)THE TOTAL VOLUME OF ALL UNPROTECTED CEILING POCKETS IN A COMPARTMENT DOES NOT EXCEED __ Pressure Gauge O 0°' I' Y 100 FT.(2.83 Ma). m Sprinkler Orifice u-.0 (Optional) Z o w 06- (2)THE ENTIRE FLOOR UNDER THE UNPROTECTED CEILING POCKET IS PROTECTED BY THE SPRINKLERS N _ ry O' 0' AT THE LOWER CEILING ELEVATION. E Y - Uponor WarningSigns I� `D m VI o (3)*THE INTERIOR FINISH OF THE UNPROTECTED CEILING POCKET EXCLUDING DECORATIVE 5 �- Tenslow Test w 0 5 J w TREATMENTS IS NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE MATERIAL. To ensure the system provides enough water for proper fire sprinkler .--w f m,�... (4)SKYLIGHTS NOT EXCEEDING 32 FT2(2.97 M2)SHALL BE PERMITTED TO HAVE A PLASTIC COVER. performance,you should conduct a flow verification test. J o • 8.3.8 SPRINKLERS SHALL NOT BE REQUIRED IN CLOSETS IN GARAGES AND EXTERIOR CLOSETS - I� is=f F Note: The NFPA 13D Installation Standard does not require flow /r1 5�;m J w oa (REGARDLESS OF SIZE)LOCATED ON EXTERIOR BALCONIES,EXTERIOR BREEZEWAYS/CORRIDORS,OR - verification. ~{ V O_.- ACCESSED FROM OUTDOORS WHERE THE CLOSET DOES NOT HAVE DOORS OR UNPROTECTED -s IL =m o F g o, PENETRATIONS DIRECTLY INTO THE DWELLING UNIT. a Main Fire Sprinkler G 3 w 5 5 a Before performing a flow verification test,confirm the water pressures by a 2 • 8.3.9 SPRINKLERS SHALL BE INSTALLED IN ANY CLOSET USED FOR HEATING AND/OR AIR-CONDITIONING - z = Shut-off Valve o 0 u w O' p contacting the Water and he Department of your hl city. Ensure the. a u 0 z EQUIPMENT,WASHERS AND/OR DRYERS,OR WATER HEATERS EXCEPT AS ALLOWED BY 8.3.8. available water pressure matches the pressure used in the system design. F 18. INSULATION GUIDE LINES PER NFPA 13D. - f Note: The sprinkler plan indicates the most hydraulically remote sprinkler SHEET DESCRIPTION • 9.1.1*WET PIPE SYSTEMS IN AREAS ABOVE 40.F. A WET PIPE SYSTEM SHALL BE PERMITTED TO BE TO BE - = (or pair of sprinklers). For test requirements on other sprinklers,consult GENERAL NOTES&DETAILS USED WHERE ALL PIPING IS INSTALLED IN AREAS MAINTAINED ABOVE 400F,INCLUDING AREAS PROPERLY a your local code. INSULATED TO MAINTAIN 40°F. •• A.9.1.1 IN AREAS SUBJECT TO FREEZING,CARE SHOULD BE TAKEN IN UNHEATED ATTIC SPACES TO Note: It is a good idea to notify the fire inspector at least 24 hours prior to a+ COVER SPRINKLER PIPING COMPLETELY WITH INSULATION. INSTALLATION SHOULD FOLLOW THE performing a flow verification test. This may speed up the inspection `,--9- p GUIDELINES OF THE INSULATION MANUFACTURER.FIGURE A.9.1.1(A)THROUGH FIGURE A.9.1.1(F) process and eliminate the need to repeat the test for the inspector. SHEET NUMBER SHOW SEVERAL METHODS THAT CAN BE CONSIDERED. THESE ARE FOR ILLUSTRATIVE PURPOSES ONLY. 5 CONSULTATION WITH THE GENERAL CONTRACTOR AND/OR OWNER IS RECOMMENDED TO ENSURE Note: See"AquaSAFE Flow Test Instruction Sheet"(Provided in PROPER METHODS AND MATERIALS ARE USED TO MAKE SURE 40°F WILL BE MAINTAINED. I Contractors Documents package or online at www.Uponorpro.com)for more information on Flow Test Setup,Assembly,Performing the Test and 5 Troubleshooting. If there are any questions please contact Uponor. U © UPONOR - CONFIDENTIAL FO 0 1