Loading...
Report (7) Building#1 9510 SW Greenburg Rd. FPS2016-00149 Building#2 9520 SW Greenburg Rd. FPS2016-00150 Building#3 9530 SW Greenburg Rd. FPS2016-00151 Building#4 9570 SW Greenburg Rd. FPS2016-00152 Building#5 9580 SW Greenburg Rd. FPS2016-00153 Building#6 9590 SW Greenburg Rd. FPS2016-00154 a RECEIVED • AUG 3 1 2016 Integrated West Technologies CITYOFTIGARD Sandy, Oregon BUILDING DIVISIGIV 503-476-2106 Reference: Fire Alarm System Greenburq Road Apartments 9550 S.W. Green burg Rd Tigard, OR 97202 Product Data Sheets August 12, 2016 S INTELLIKNIGHT FIRE ALARM CONTROL PANEL • SILENT Intel iKn ght® 5808 KNIGHT Single Loop Addressable Fire Alarm Control System by Honeywell The convenience of an addressable fire alarm control panel in a cost-effective easy to use package. IntelliKnight Model 5808 is a 127 point class leading single loop addressable fire alarm control/communicator system. 5808 provides you with the revolutionary value and performance of addressable sensing technology combined with exclusive, built-in digital communication, distributed intelligent power, easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Description The basic 5808 system can be enhanced by adding modules such as 5860 remote annunciator, 5824 serial/parallel printer interface module (for printing system reports), and 5496 intelligent power module. 5808 supports a SD or SK protocol devices. 5808 also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. .c . Features • Built-in support forup to 99 SK detctors and 99 SK 'z modules. • Built in support for 127 SD devices. • Up to 125 zones and 125 output groups. • Uses standard wire—no shielded or twisted pair required z� • Built-in digital communicator. Model 5808 • Central station reporting by point or by zone • Plex-2 door option combines a dead front • Supports Class B (Style 4) and Class A(Style 6 or 7) cabinet door with a clear window, limiting configuration for SLC. access to the panel while providing single • Distributed, intelligent power. button operation of the reset and silence • Drift compensation. functions. • 13 pre-programmed output cadences, (including ANSI- • Integrated dead front panel protects operator 3.41), and 4 programmable outputs. from exposure to electrical components. • Notification circuitscan be configured as 2 Class A (Style Z)or 4 Class B (Style Y), or auxiliary power for • The FACP enclosure features a Plexiglass® resettable, constant, or door holder power. viewing window to protect annunciator. • wilt-in:annunciator with SO-character LCD display. • Acknowledge function allows operator to keep • RS-485 bus provides communication to system track of event status. accessories. • Built-in RS-232 and USB interface for programming Installation via a PC. The 5800 can be surface or flush mounted. • Upload or download programming, event history, or ti detector status via remote or direct connection. Compatibility • Improvements in SKSS deliver five times faster The 5808 signal line circuit (SLC)supports upload/downloads. multiple device types of the same protocol: • Built-in synchronization for appliances from AMSECO, • SK 410 Gentex®, Faraday, System Sensor®, and Wheelock®. • SD • One Form C trouble relay rated at 2.5A at 27.4 VDC and You cannot mix SD and SK SLC devices on a two Form C programmable relays rated at 2.5A at 27.4 FACP. VDC. INTELLIKNIGHT FIRE ALARM CONTROL PANEL • IMO .7,1,?r!Ai2,9 *,..,,, .7t),) * -,e w ",,,, x .„,„,, , mit 4880 mccea.� ez,l erx'�m I NM 1' ,>•.9•,,, A .. �... lak 7— 5496 +11 w,._..: 5808 Specifications Protected Premises Unit; &Water Deluge Miscellaneous Accessories Electrical Releasing Service. Suitable for automatic, 5660 Silent Knight Software Suite Primary AC: 120 VRMS at 50/60 Hz, manual,waterflow, sprinkler supervisory (DACT non-coded)signalling services. PC base software for FACP 2.75A UL Listed programming. Upload and view panel Total Accessory Load: 6A @ 27.4 CSFM 7165-0559:0142; account information, event history, and VDC MEA 429-92-E Vol. XIV detector status. Notification Power: 6A©27.4 VDC, OSHPD (CA)OSP-0065-10 5670 Silent Knight Software Suite power-limited End-user facilitymanagement software Standby Current: 170 mA S-BUS Accessories allows viewing of detector status and Alarm Current: 365 mA 5860/R Remote Fire Annunciator event history via modem or direct Notification&Auxiliary Circuits: Features the same 80 character backlit connection. 3A @ 27.4 VDC per circuit,power- LCD display keypad and firefighter's key limited switch as the 5808. 5860 is gray and Plex-2 Door IP Battery Charging Capacity: 5860R is red. 5496 Intelligent Power Module Dead front cabinet door with clear 7.0-35 AH window to limit access to the FACP. Battery Size: 18 AH max. allowed in A 6 amp notification power expander that RBB FACP. Larger capacity batteries can provides four additional power-limited Remote Battery Box Accessory be housed in an RBB accessory notification appliance circuit outputs. Cabinet. Use if backup batteries are cabinet too large to fit into FACP cabinet. 5880 LED/IO Module Dimensions: 16"W x 10" H x 6"D Physical Features 40 LED outputs, 8 normally open (406 mm W x 254 mm H x 152 mm D) Flush Mount Dimensions: dry contact inputs and one piezo output. 14.5"W x 24.75" H x 3.5" D SK-SCK (36.8 W x 62.9 H x 8.73 D cm) 5865-3 and 5865-4 Seismic Compliance Kit Remote LED Annunciator Overall Dimensions: Features 30 programmable LED(15 red SD and SK Devices 16"W x 26.4" H x 4.65" D and 15 yellow)outputs and a piezo See the specification sheets listed (40.6 W x 67 H x 11.8 D cm) sounder.The 5865-4 adds a silence and below for a complete listing of the SD Weight: 28 lbs. (12.8 kg) reset switch to the package. and SK devices. Color: Red 5824 Serial/Parallel Printer 53624 SD Devices data sheet Telephone Requirements: Interface Module 53623 SK Devices data sheet FCC Part 15 and Part 68 approved Provides one parallel and one RS-232 Type of Jack: RJ31X(two required) serial port for connecting a printer to 5808. Approvals Use to print a real-time log of system NFPA 13, NFPA 15, NFPA 16, NFPA events, detector status reports, and event 70, &NFPA 72: Central Station; history. Remote Signalling; Local Protective 5883 Relay Board IntelliKnight&JumpStart are Registered Signalling Systems;Auxiliary Features 10 general purpose Form C Trademarks of Silent Knight Flexput is a relays. Used with 5880 module. Trademark of Silent Knight SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA keep our product information up-to-date and accurate.We cannot cover all • Iii KNIGHT specific applications or anticipate all requirements.All specifications are 350386 Rev.L subject to change without notice.For more information,contact Silent Knight ©2013 Honeywell International Inc. by Honeywell 12 Clintonville Road,Northford,CT 06472-1610.Phone: (800)328-0103, Fax:(203)484-7118. For Technical Support,Please call 800-446-6444. www.silentknight.com INTELLIKNIGHT ACCESSORY •, 4irt SILENT 51360 Remote Annunciator KNIGHT by Honeywell Bring the power to control an IntelliKnight fire alarm control panel to every area within your facility - Now you can operate and program your IntelliKnight system from up to twelve locations throughout your facility. The 5860 remote annunciator provides the same advanced, easy-to-use interface found on the IntelliKnight panel's built-in annunciator. The 80-character display and ergonomically designed keypad allow for simple and . error-free system operation.All operations—including reset, silence, detector status checking, fire drill, and programming—are identical. Access to the system is through a firefighter's key or an access code. For security, a special installation code is needed for programming functions. The 5860 connects to the IntelliKnight panel via the RS-485 system bus. Wire runs can be up to 6000 feet from the panel. For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Description • Available in red or light gray Features include an 80-character • Support for simultaneous use of backlit LCD providing easy-to- multiple 5860s understand system messages. The • RS-485 interface to panel4111 annunciator is ergonomically • Operation and appearance is designed with over-sized buttons identical to 5860 built-in for the most frequently used annunciator , m features, like Reset and Silence. • On-board piezo sounder audibly i indicates alarms, troubles, and In addition to status messages supervisories - displayed on the LCD, there are supervisory, • Five status LEDs for alarm, five LEDs for alarm, su p ry, supervisory, trouble, silence and trouble, silence, and AC power AC power conditions status. • Wiring lengths up to 6000 ft. from 5860 The annunciator is available in gray the FACP (depending on wire Environmental to match virtual) anydecor and gauge and number of devices on Operating Temperature: 32°F– red for applications where the SBUS) 120°F (0°C–49°C) annunciator must stand out. The • UL listed, complies with NFPA 72 Humidity: 10%–93% non- annunciator enclosure can be • CSFM approved condensing surface or flush mounted.A trim Electrical Specifications Compatibility ring kit is available for surface Operating Voltage: 24 VDC The 5860 is compatible with the, mounting. Standby Current: 20 mA max following ACPs: Features Alarm Current: 25 mA • 5820XL Addressable Fire Control • "80-chi,rt 'backlit 4D":display' Wiring Distance: 6,000 max. from Panel (4 lines with 2a characters on FACP (depending on wire gauge • 5820XL-EVS Fire Control Panel each line) and number of devices on the with Emergency Voice System • Tactile and audible feedback SBUS) • 5808 Addressable Fire Control • Accepts user codes or fire Panel. fighter's key Mechanical Specifications - • Larger keypad buttons for system Physical 9.1"W x 7.4" H x 1.5" D • Pa0nel0 Addressable Fire Control reset and;silence (23.1 W x 18.8 H x 3.8 D cm) • • -install up to twelve 5860e per; Shipping Weight: 2.8 lbs (1.3 kg) 588XL/EVS or 5808 system • Install up to eight 5860s per 5700 Color PN 350224 Rev G 5860R: Red system ©2014 Honeywell International Inc 5860: Gray INTELLIKNIGHT ACCESSORY i 5860 Remote Annunciator Engineering Specifications The main control must have a built-in annunciator and must support up to 12 remote annunciators. Remote annunciators shall have the same control and display layout so as to match the appearance of the built-in annunciator. Remote annunciators shall be available in two colors, red or light gray. Remote annunciators shall have identical functionality and operation as the built-in annunciator.All annunciators must have an 80-character LCD display and must feature five LEDs for: General Alarm, Supervisory, System Trouble, System Silence, and System Power. All controls and programming keys are silicone mechanical type with tactile and audible feedback. Keys have a travel of.040 inches. No membrane style buttons will be permissible. The annunciator must be able to silence and reset alarms through the use of a code entered on the annunciator keypad or by using a firefighter's key. The annunciator must have two levels of user codes that will limit the operating system programming to authorized individuals. The control panel must allow all annunciators to accommodate multiple user input simultaneously. Wire Runs Up to 6000 Feet From FACP SBUS 4Atv. 410 5860 5860 5860 • Up to 12 5860s Per IFP-100IECS or IFP-1000/ECS System a *Up to Eight 5860s Per 5700 System Compatible intelliKnight FRCP Listings Ordering Information NFPA 72; UL Listed; 5860R Remote Armani ator four line LCD CSFM 7170-0559: 135; annunciator with 20 characters perline,'. MEA 429-92-E Vol. IX; Red FM Approved 5860 Remote Annunciator four line LCD annunciator with 20 characters per line. Gray Accessories 5860TR Red Trim Ring for surface mounting 5860TG Gray Trim Ring for surface mounting SILENT This document is not intended to be used for installation purposes.We try to KNIGHT keep our product information up-to-date and accurate.We cannot cover all , • specific applications or anticipate all requirements.All specifications are � • by Honeywell subject to change without notice. For more information,contact Silent Knight 12 Clintonville Road, Northford,CT 06472-1610.Phone:(800)328-0103, Fax:(203)484-7118.For Technical Support,Please call 800-446-6444. www.silentknight.com Assembled in America FIRE SYSTEM ACCESSORY i SILENT 5 6i wint elii . nt KNIGHT Poer Module by Honeywell A dynamic combination of power and intelligence for your notification expansion needs. The Model 5496 Intelligent Power Module by Silent Knight is the most-powerful and cost-effective power supply available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensor®, Gentex®, Faraday,AMSECO and Wheelock®—what you need to drive power-hungry components like ADA notification appliances. The 5496's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. For the most sophisticated and cost-effective notification power supply available, you need Model 5496. Call Silent Knight today for more information at 1-800-328-0103. Model 5496 power Intelligent Power Module • 3 amps per output circuit 1 The model 5496 is a 6 amp notification • Ground fault detector ) power expander that provides its own • Communicates to the FACP via 4- AC power connection, battery charging wire SBUS (wire runs up to 6000 ft) circuit, and backup battery for use with • AC loss delay option shuts off power al fire and security controls such as the to non-essential high-current IntelliKnight Model 5808 Fire Control accessories like magnetic door /Communicator.The 5496 is the cost- holders effective solution for powering • Lightweight design adds to ease of notification appliances required by the installation and reduces shipping Americans with Disabilities Act(ADA). costs The 5496 has built-in ANSI cadence pattern, which can upgrade older • UL 864,1481 & 1971 listed control panels that lack cadence • ANSI Cadence pattern output capability.The Output circuits can be capability built-in programmed as Notification Appliance Specifications ;111,1. Circuits, or as Auxiliary Power ' (configurable for, constant, resettable, AC Input: 120 VAC at 2.7 A or door holder power). Output: 24 VDC at 6 amps 5496 Intelligent Power Module Features Current: _ UL Listed for 6 smps of notification, Standby 40 mA Ambient Temp.: 32°to 120° F (0°to 49° C) power Alarm 160 mA • Power supply's advanced switch Dimensions: mode design reduces damaging Notification/Aux.Power circuits: 4 12.25"W x 16"H x3" D heat and manages power up to 50% (30.88 Wx 40.64 H x7.62 D more efficiently than other systems Output configuration: cm) 2 Class A(Style Z) Listings: • �t-in synchronization for` -4 Class B (Style Y)(1 Class A&2 9 UL - pliances from AMSECO, Gentex®, Class B) ap CSFM Faraday,System Sensor®, and Amps per output circuit: MEA 429-92-E vol. XIV Wheelock® 3.0 (6.0 amps total) • 24 VDC filtered output voltage Compatible FACPs Notification circuit output: - • Four power-limited notification • IntelliKnight 5700 20.4 to 27.3 VDC, 3.0 amps each, outputs; 2 Class A or 4 Class B, or 1 4.7k EOL resistor required on each • IntelliKnightt5808'; Class A and 2 Class B Class B circuit • IntelliKnight 5820XL ill • NACs are programmable as • IntelliKnight 5820XL-EVS Notification Appliance Circuits,or as Battery charging capacity: 35.0 AH auxiliary power to be used as constant, resettable, or door holder FIRE SYSTEM ACCESSORY • Firepower 5496 Distributed Power Module Engineering Specifications The contractor shall supply a power module compatible with the Silent Knight FACP. The power module must have 6.0 amps of output power. The power module shall connect to the main FACP via an RS 485 system bus (SBUS). The Outputs shall be programmable as Notification Appliance Circuits, or as Auxiliary Power (configurable for, constant, resettable, or door holder power). The power module shall have four separate outputs. The power module RS 485 bus shall be optically isolated providing ground loop isolation and transient protection. 4 Outputs Programmable as Notification Appliance Circuits, • or as Auxiliary Power Output 1 44 SBUS Communication To a Compatible Output 2 Silent Knight FRCP ) 4111 Op,. Output 3 41111111 Output 4 -44 cE.E Auxiliary Power Can Be it Programmed To Be Constant, Resettable, or Door Holder Power thSILENT This document is not intended to be used for installation purposes.We try MADE IN AMERICA j KNIGHT to keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are FORM#350387 Rev E . subject to change without notice. For more information,contact ©2013 Honeywell International Inc. by Honeywell Silent Knight 12 Clintonville Road,Northford, CT 06472-1610 Phone: (800)328-0103,Fax: (203)484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com Honeywell • IPGS11.40 Single or,Dual Path commercial Fire Communicator General The IPGSM-4G is a commercial fire alarm communicator that is offers contact ID reporting with any Fire Alarm Control Panel (FACP)that has a built-in dialer. This single or dual path com- municator connects directly to the primary and secondary communication ports of a fire panel's Digital Alarm Communi- cator Transmitter (DACT). it offers three selectable reporting paths which Include;Cellular only, IP only, or IP primary/cellu- lar backup All signals from the IPGSM-4G are delivered to Honeywell's AlarmNet Network Control Center, which routes highly encrypted Ethernet data packets via a customer pro- vided internet connection or cellular network to the appropriate central station. The state of the art AlarmNet network control center is fully redundant and monitored 24/7. AlarmNet has • Multi-GSM platform compatibility for 2G, 3G and 4G net- the ability to route messages using AlarmNet-1 and 800 PLUS works. services, providing true redundancy and multipath message delivery. • Operates over the following communication protocols: HSPA+ (4G) HSPA (HSDPA & HSUPA) (3G) EDGE (2G) Alternative communication methods are critical in the market- GPRS(2G). place due to VoIP(Voice over IP), migration from POTS(Plain • Selectable reporting paths and supervision intervals to Old Telephone Service) and growth of digital radio networks. meet NFPA 72, chapter 26 requirements. (Compliant with The IPGSM-4G's single path communications solution allows NFPA 72 2010 and 2013 supervision requirements.) one technology to be used(Either IP or cellular)to provide the appropriate connectivity to a central station. For added reliabil- • Works over any type of customer provided Ethernet 10/100 • ity, our exclusive dual path solution allows both technologies based network connection (LAN or WAN), DSL modem or (IP and cellular)to be used together for maximum survivability cable modem. or for local jurisdiction requirements that specify a dual tech- • Data transmits over standard contact-ID protocol but is nology system. secured with the industry's advanced encryption standard The IPGSM-4G is designed to operate over the most common (AES 256 bit). cellular networks including 2G,3G and 4G. Its multi-GSM plat- • Supports both dynamic(DHCP)or Public and Private Static form technology automatically chooses the best available cel- IP addressing. lular signal in the area based on signal strength and • Built-In Power Supply module: On board charging circuit seamlessly self-adjusts to maintain critical life safety communi- design accommodates back-up battery. Includes primary cation. In addition, it connects to any type of customer pro- power and battery supervision. vided Ethernet 10/100 base network connection (LAN or • Diagnostic LEDs:Signal strength and status indicators. WAN), DSL model or cable modem. Our selectable reporting path feature allows the radio to be configured for a single or • Reliable connection: IP and GSM connection tested every dual path solution as well as the appropriate supervision inter- day. vals based on NFPA 72 requirements. (See diagram below for • QOS: Quality of Service diagnostics via AlarmNet conveys selectable paths and supervision timing intervals.) vital communicator information including when message was received,signal strength,and message path used. • 7720P Hand-held programmer for easy setup. Selectable Path Description Supervision Times Operation 2010 GSM Single Path(cellular only) 5 minutes When an event occurs, the Fire Alarm Control Panel goes off 2010 IP Single Path(IP only) 5 minutes hook to dial the central station.The IPGSM-4G Dialer Capture Module detects the off-hook condition and provides the fire 2010 IP&GSM Dual Path(IP and cellular) 24 hours panel with a dial tone. When the fire panel detects the dial 2013 GSM Single Path(cellular only) 1 hour tone, it begins dialing the central station. After the dialing is completed,the Dialer Capture Module returns a handshake to 2013 IP Single Path(IP only) 1 hour the fire panel.The fire panel then sends the contact ID reports 2013 IP&GSM Dual Path(IP and cellular) 6 hours to the Dialer Capture Module, which in turn sends a kiss-off after the report is successfully received from the fire panel. The Dialer Capture Module sends the contact ID reports to the Features IPGSM communications module. When all the reports are • Saves the cost of two dedicated phone lines. sent, the fire panel goes on-hook. The IPGSM communica- • • Single or dual path communications. (Can communicate to tions module then transmits the messages to the central sta central station using cellular technology,internet or both. tion either over the GSM network or the Internet (dependent on configuration). • Requires no change to the existing Fire Alarm Control Panel configuration. (Connects directly to the primary and secondary telephone ports of a DACT.) Easy to Program -One 12 V 7.0 AH lead-acid battery(not supplied). • The IPGSM-4G communicator can be pre-programmed using —Battery charging current: 1 Amp maximum. the 7720P programmer to enter all central-station information. —Battery discharge current: Standby 230mA, Active This is saved to the IPGSM-4G communicator panel memory. 950mA. When the IPGSM-4G communicator is installed at the site and connected to the Internet/Intranet, it registers itself with the Cabinet Specifications AlarmNet receiver. Dimensions: 14.875"H x 12.75"W x 3.0"D(37.8 cm H x 32.4 .For most installations,the only required parameters are: cm W x 7.6 cm D). • Primary City ID (two digits) obtained from your monitoring Color: Red. station. • Primary Central Station ID (two digits) obtained from your Shipping Specifications monitoring station. Weight:5.3 lbs. (6.94 kg). • Primary Subscriber ID(four digits)obtained from your mon Dimensions: 15.625" H x 13.79" W x 9.25" D (39.7 cm H x itoring station. 34.9 cm W x 23.9 cm D) • Communication Module's MAC ID, and MAC CRC number located on outside of box,and inside of the module. Temperature and Humidity Ranges All of these parameters are assigned by the monitoring station. This system meets NFPA requirements for operation at 0 - NOTE: Some assembly is required. See Installation and Setup 49°C/32-120°F and at a relative humidity 93%t 2%RH(non Guide#800-12454 for full details. condensing at 32°C t 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic corn- Fire Communicator Capability ponents may be adversely affected by extreme temperature The IPGSM-4G is compatible with fire panels that use the ranges and humidity. Therefore, it is recommended that this Contact ID communications format as described in the SIA system and its peripherals be installed in an environment with DC-05 standard. a normal room temperature of 15-27°C/60-80°F. AlarmNet Product Line Information Honeywell's AlarmNet has been the nationwide leader in IPGSM-4G: Internet and Digital Cellular Fire Alarm Communi- alarm communications technology since 1986.A reliable alter- cator Panel. Includes red cabinet with Ademco key and lock, native for the transmission of alarm signals,our radio network wall outlet box, Dialer Capture Module, IGSM Communications provides extensive coverage in the United States and Canada. Module, antenna & mounting adapter, PowerBoostl power 110 AlarmNet Network Control center processes signals from pow- supply, LED display board, transformer, manual, & required erful servers in multiple locations equipped with 24/7 infra- screws,cables,etc. structure support.The AlarmNet network consist of redundant Antenna Kits hardware servers, hot back-up databases and generators with GSM-ANT3DB25KT:25 ft.antenna kit.Includes GSM-ANT3DB, battery back-up at all locations to ensure continuity of service. WA7626-CA adapter cable,and a 25'RF cable. Signals from Alarm-Net are transmitted to the central station's GSM-ANT3DB5OKT:50 ft.antenna kit. Includes GSM-ANT3DB, receivers using multiple communications paths consisting of WA7626-CA adapter cable,and a 50'RF cable. the Internet, radio network or toll-free POTS service. Antenna External Hardware Installation Requirements GSM-ANT3DB:3db gain external/remote antenna. WA7626-CA: SNA to N Adapter. UL COMPLIANCE 7626-50HC:50 ft.antenna cable, low loss. To meet UL864/NFPA,ensure the following: 7626-25HC:25 ft.antenna cable, low loss. • IPGSM-4G must be installed in accordance with NFPA NOTE: The GSM-ANT3DB and the WA7626-CA are both required (National Fire Protection Association)standards 70 and 72. for installing an external antenna along with the necessary cable needed(7626-50HC:50 ft.or 7626-25HC:25 ft.) • IPGSM-4G must be mounted in the same room and within 20 feet of the fire panel. Other Accessories • IPGSM-4G, and all equipment used for the IP connection 7720P: IPGSM-4G hand held programmer. (such as the router, hub, modem, etc.)shall be listed, must HPTCOVER:Plug in transformer box for IPGSM communicator. be powered from an un-switched branch circuit,and be pro- BAT-1270: Battery 12 Volts,7 AH,sealed. vided with appropriate standby power. • IPGSM-4G must use the 7AH battery(not supplied)to pro- Agency Listings and Approvals vide 24-hour backup capability. The listings and approvals below apply to the basic IPGSM-4G communicator panel. In some cases,certain modules may not be Electrical Specifications listed by certain approval agencies,or listing may be in process. Transformer: Consult factory for latest listing status. —Primary 120VAC,60Hz,0.5A. UL Listed:S789. —Secondary: 18VDC,50VA. CSFM:7300-1645:0199. Battery: FDNY:COA#6150. • Page 2 of 3—DH-60769:B•3/25/13 www.honeywell.com • This document is not intended to be used for installation purposes.We try to keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are subject to change without notice. ©2014 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. Automation and Control Solutions Honeywell Honeywell 12 Clintonville Road 1(877)HPP-POWR • Northford,CT 06472-1610 hpp_techsery@honeywell.com www.honeywellpower.com DH-60769:8 April 2014 Made inU.S.A. 'Q® ®U.S.Registered Trademark V 02014 Honeywell International Inc. MUMMY EMANYfACHIPA Page 3of3 QUALITY SYSTEMS INTELLIKNIGHT ACCESSORY • SILENT SK-Pull-SA andSK-Pull-DA KNIGHT • by Honeywell Intelligent Pull tations The SK-Pull-SA and SK-Pull-DA are a single action or dual action addressable fire alarm pull station for use with Silent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SK-Pull-DA and SK-Pull-SA provide a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Description The SK-Pull-SA is a single action pull station requiring only one motion to activate the station.The SK-Pull-DA is a dual action pull station requiring two motions to active the station. Both pull stations are designed to work with Silent Knight PULL I DOWN Intelliknight series fire alarm control panels (FACPs). Features • Installer can open station without causing an alarm ••''"' 111 conditionSli..1.1k I KNK,Hr • Dual-color LED is visible through handle of station blinks green to indicate normal operation and remains steady red in an alarm condition SK-Pull-SA • Key operated test and reset lock using lock plate actuator • Key matches compatible FACP locksR • Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG) controls and operating mechanisms I PUSH IN guidelines (Section 4.1.3[13]) PULLDOWN • Meets ADA requirement for 5 lbs maximum pull force to active • Shell, door, and handle molded from durable LEXAN® KNIGHT • Reliable analog communications for trouble-free operation • Braille text on station handle SK-Pull-DA • Handle latches in down position and the word Activated Compatibility appears, clearly indicating the station has been pulled The SK-Pull-SA and,SK-Pull-DA are compeitible • • Rotary address switches for fast installation with the following IrtelllKnight:F.AI.P's: 5600 • UL Listed, including UL 38, Standard of Manually Actuated 5700 • Signaling System 5808 5820XL 5820XL-EVS INTELLIKNIGHT ACCESSORY Model SK-Pull-DA and SK-Pull-SA Intelligent Pull Stations Engineering Specifications The contractor shall furnish and install where indicated on the plans,Addressable Pull Stations, Silent Knight • model SK-Pull-SA single action pull station or SK-Pull-DA, dual action pull station. SK-Pull-DA or SK-Pull-SA meet the ADAAG controls and operating mechanisms guidelines, and the ADA requirements for a 5 lb. maximum pull force to activate the pull station. Class A Class B Cornpatlble FACP - T pg •Class A wiring:^•^^^•-• .:.` Class B Wiring: Wiring SK-Pull-SA&SK-Pull-DA Pull Stations Specifications Electrical Physical Operating Voltage: 15-32 VDC Height: 5.5"(14 cm) Average Operating Current(LED flashing): 300 pA Width:4" (10.2 cm) Wire Gauge: Up to 12 AWG (3.1 mm2) Depth: 5.4 oz. (3.7 cm) Environmental Housing Material: LEXAN polycarbonate resin Operating Temperature 32°— 120°F (0°C—49°C) Bi-Colored LED: Humidity: 10%—93% non-condensing Blinking Green: Normal Steady Red:Alarm Accessories Switch: Single pole, single throw(SPST)normally open (N/O) BG-TR Optional trim ring. switch which closes upon activation of the pull station SB-I/O Surface backbox SILENT This document is not intended to be used for installation purposes.We try MADE IN AMERICA • to keep our product information up-to-date and accurate.We cannot cover KNIGHT all specific applications or anticipate all requirements.All specifications are subject to change without notice.For more information,contact Silent FORM#350135 Rev C • by Honeywell Knight 12 Clintonville Road,Northford, CT 06472-1610 ©2013 Honeywell International Inc. Phone:(800)328-0103,Fax:(203)484-7118.For Technical Support, Please call 800-446-6444. www.silentknight.com INTELLIKNIGHT ACCESSORY • SILENT SK-Photo, SK-Photo-T t'S KNIGHT and SK-PhotoR by Honeywell - Intelligent Photoelectric Smoke Sensors The SK-Photo is a photoelectric smoke detector, the SK-Photo-T is a photoelectric smoke detector with thermal and SK-PhotoR is a photoelectric detector with remote test capability. These plug in smoke detectors, with integral communication, provide features that surpass conventional detectors and are for use with Silent Knight IntelliKnight Fire Alarm Control Panels (FACPs). For more information about the IntelliKnight system, or to locate your nearest source, please call 800-328-0103. Description • Optional remote LED annunciator (System Sensor®PN RA100Z) ,- , s SK-Photo and SK-Photo-T are plug-in • Plug in mounting provides ease of ,- ,, type smoke sensors that combine a installation .• r photoelectric sensing chamber with addressable analog communications. • Tamper-proof feature available on 3 , Point ID capability allows each mounting bases detector's address to be set with rotary • Listed for use in duct applications ,„„)...,j, address switches, providing exact • Rotary address switches for fast ) detector locations for selective installation maintenance when chamber • UL Listed ,i contamination reaches unacceptable . FM Approvede.i M -, - • levels. Specifications SK-Photo and SK-Photo-T have a ` , f i r/ -: unique optical sensingchamber that is !. ' q p Physical engineered to sense smoke produced Height: 2.0" (5.0 cm) SK-Photo (Base included) by a wide range of combustion Diameter:4.1"(10.4 cm)installed in sources. In the SK-Photo-T, dual B501 base electronic thermistors add 135°F (57°C) Installation thermal technology to maximize Electrical Operating Voltage: 15-32 VDC The SK-Photo and SK-Photo-T plug detection. P 9 9 Standby Current: into a compatible IntelliKnight-series The SK-PhotoR is a remote test detector base.The SK-PhotoR is a capable detector for use with the 300 pA @ 24 VDC Maximum remote test capable detector head DNR/DNRW duct smoke detector. (not Alarm Current: 6.5 mA @ 24 VDC max included within the DNR(W)duct included) (with LED on) smoke detector. Environmental Operating Temperature Compatibility Features SK-Photo: 32°—120°F (0°C—49°C) SK-Photo, and SK-Photo-T are • Sleek, low-profile design SK-Photo-T: 32°—100°F (0°C—38°C) compatible with the following detector • Base included Humidity: 10%—93% non-condensing bases: • Reliable analog communications for Other Ratings BP'" "base(included) trouble-free operation SK-Photo-T Thermal: Fixed B501 2 wire base B224RB Relay base • Age resistant polymer housing temperature set point 135°F (57°C) B224B1 Isolator base • Dual electronic thermistor design on Velocity: 0—4000 fpm (0—20 m/sec) B200SR Sounder base the SK-Photo-T The SK=Photo,SK-Photo-T,and 5K' • Superior EMI resistance for reliability PhotoR are compatible with the • Simple field cleaning for code followingInfelliKnight FACPs: compliance 5820XL • Variety of mounting options to meet 5820XL-EVS III 08 any application 5700 • Dual LED indicators for 360°visibility 5600(Rev 2.0 or higher) • Detector transmits signal to indicate maintenance is required INTELLIKNIGHT ACCESSORY Model SK-Photo, SK-Photo-T and SK-PhotoR Intelligent Photoelectric Smoke Sensors Engineering Specifications The contractor shall furnish and install where indicated on the plans, Intelligent photoelectric smoke sensors Silent Knight SK-Photo or SK-Photo-T with thermal. The combination detector head, and twist-lock base, shall be UL listed and compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with SK-Photo or SK-Photo-T. Base shall be the appropriate twist-lock base part number B210LP (included). The PhotoR is a remote test capable detector for use with DNR(W) duct smoke detectors. (not included). The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SK-Photo shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. • ,.-` $LC IN OUT/ g )! Compatible FACP ILTI RAIOOZ(Optional) to,WN (INN %re 1:1°131 \air Class A Optional Wiring Wiring SK-Series Detector Mounting Bases SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate.We cannot cover all • specific applications or anticipate all requirements.All specifications are FORM#350118 Rev E subject to change without notice.For more information,contact Silent Knight ©2013 Honeywell International Inc. by Honeywell 12 Clintonville Road, Northford,CT 06472-1610 Phone: (800)328-0103, Fax:(203)484-7118. For Technical Support,Please call 800-446-6444. www.silentknight.com INTELLIKNIGHT ACCESSORY • SILENT KNIGHT (F "'. by Honeywell The SK-ISO Isolator Module enable part of a communication loop to continue operating when a short circuit occurs on it. If a short occurs between any two isolators, then both isolators immediately switch to an open circuit state and isolate the device between them. • For more information about the IntelliKnight system, or to locate you nearest source, please call 800-328-0103. Description ". The SK-ISO is an addressable line isolator module for N ; use with Silent Knight IntelliKnight series fire alarm control ' panels (FACPs). The SK-ISO acts as an automatic switch that opens when s« �� the line voltage on the signaling line circuit (SLC) loop drops below four volts. Isolator modules should be spaced between groups of sensors or modules in a loop to VxM t ' protect the rest of the loop. If a short occurs between any " two isolators, then both isolators immediately switch to an 411 open circuit state and isolate the devices between them. • a, Lam.•. The remaining units on the SLC loop continue to fully \ operate. No more than 25 devices are recommended for each group. Features SK-ISO • Panel controlled status LED that flashes green in normal state and is solid red in alarm Compatibility The SK-ISO to ped$a ' h e� 1094 4.114 04**; • Isolates short circuits on an SLC loop IntelliKnight ; 5700 • Protects the modules on the SLC loop so other devices 5808 continue to operate 5820XL 5820XL-EVS • Standard 4 inch electrical box mounting SK-FFT • SEMS screws for easy wiring • UL Listed Installation The SK-ISO mounts directly into a 4" square electrical box. The box must have a minimum depth of 2-1/8".A surface mount electrical box (System Sensor® PN SMB500) is available from Silent Knight. • P/N 350134 Rev E ©2016 Honeywell International Inc. INTELLIKNIGHT ACCESSORY 410 Model SK-ISO Intelligent Isolator Module SK-ISO Isolator Module SK-ISO Isolator Module - C O 0 O I 1(.) isolated Devices 1(-) 2(+) 2(+) 4(+) , _2(+ } 2(+) 4(-) 11; Wilk Olp ark - Isolated fi + 10.1 Groups of Devices are Separated by SK-ISO Isolator Modules. Devices I IN — imp Any Combination of Compatible Listed Devices May Be fOUTSLC + Mixed Within a Group.Oft 2(+) I Gro i \' _ A Pair of SIC-ISO Isolator Modules Will Disconnect a 2(+) Compatible FACP Group of Devices if a Short Circuit Occurs on the Signaling Line Circuit Within that Group. SK-ISO Isolator Module SK-ISO Isolator Module • .+ t ' y 4110 1(_) Isolated Devices 1(-) 2(+) 2(+) 3(-) . i(-) i "1 1-) 3(-) 4(+) . 2(+) --2(+) 4(+) . illp alp V ark Wiring SK-ISO Modules Specifications Fault Detection Delay: 250 ms min. Physical Fault Detection Threshold: 4V - Height: 4.5" (11.4 cm) Line Restoration Threshold: 7V Width: 4" (10.2 cm) Environmental Depth: 0.25" (0.6 cm) Operating Temperature: 32°F— 120°F (0°C—49°C) Shipping Weight: 6.3 oz (196 g) Humidity: 10%—93% non-condensing Electrical Accessories Operating Voltage: 15—32 VDC SMB500 4"Square Surface Mount Electrical Box Standby Current: 450 pA max (not isolating; relay closed) Isolation Current: 5 mA max SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all - KNIGHT requirements.All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800)328-0103, Fax: by Honeywell (203)484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com • INTELLIKNIGHT ACCESSORY • SILENTSkor 712 �j KNIGHT by Honeywell „� • . .mt * .. The SK-Monitor-2 module is capable of monitoring two separate Class B circuits simultaneously, making it ideal for waterflow tamper switch and flow switch monitoring. For more information about the IntelliKnight system, or to locateou nearest source, please Y call 1-800-328-0103. Description The SK-Monitor-2 is an addressable monitor ipttote module with two initiating circuits for use with Silent Knight IntelliKnight series fire alarm � �� � �� control panels (FACPs). The SK-Monitor-2 acts as an interface to contact devices, such ass ; waterflow switches and pull stations. � • ,, • The SK-Monitor-2 supports Class B supervised ,.. wiring to the load device. Conventional 4-wire smoke detectors can be monitored for alarm and trouble conditions. SK-Monitor-2 Installation Features SK-Monitor-2 mounts directly into a 4” • Monitor two circuits, with unique addresses, square electrical box. The box must have simultaneously a minimum depth of 2-1/8". A surface • Support for Class B wiring mount electrical box (System Sensor® • Fully supervised part number SMB5OO) is available from • Panel controlled status LED that flashes green Silent Knight. in normal state and is solid red in alarm Compatibility • Attractive ivory cover plate The SK-Monitor2.' corns bye-r #t l thy; • Rotary address switches for fast installation following lntelliKn t • SEMS screws for easy wiring 5700 • UL Listed 5808 582OXL • 582OXL-EVS • • INTELLIKNIGHT ACCESSORY • Model SK-Monitor-2 Intelligent Dual Monitor Module To Next Device + 41 41 n Q o . FTO [ ] T7 E-1J ((�/� O Compatible FACP \� u u Two Initiating Device Circuits NFPA Style B .- Power Limited 230 pA Max 12 VDC Max \ $LC n n OUT IN Mt, la Mt, T° • ; Tr Tile ( fav ao ° o0 Wiring 8K-Monitor-2 Modules Specifications End-of-Line Resistance:47K 52 Physical Max IDC wiring resistance: 1,50052 Height:4.5" H x 4"W x 1.25" D SLC Line Loop Resistance:4052 max. Shipping Weight: 6.3 oz(196 g) Environmental Electrical Operating Temperature: 32°F—120°F (0°C—49°C) Operating Voltage: 15—32 VDC Humidity: 10%—93% non-condensing Current Draw(LED on): 6.4 mA max Accessories Operating Current(LED flashing): 750 pA SMB500 4" Square Surface Mount Electrical Box • This document is not intended to be used for installation purposes.We try MADE IN AMERICA SILENT to keep our product information up-to-date and accurate.We cannot cover KNIGH' all specific applications or anticipate all requirements.All specifications are subject to change without notice.For more information,contact Silent FORM#350124 Rev C Knight 12 Clintonville Road,Northford,CT 06472-1610 ©2013 Honeywell International Inc. by Honeywell Phone:(800)328-0103, Fax:(203)484-7118.For Tehnical Support,Please call 800-446-6444. www.silentknight.com • S STEM dOut oor Select Ou tput Horns, .. Strobes, and $ rfl, S 1besfor Wall Applications SPECT' 'A rt SpectrAlertl Advance outdoor audible visible products *.:, . ::: `.S e et s are rich with features that cut installation times and maximize profits. Features SpectrAlert Advance offers the broadest line of outdoor horns, strobes,and horn strobes in the industry.With white or red plastic housings,wall or ceiling mounting options,and plain or FIRE-printed • I isted to UL 1638(strobe)and UL.464(horn) devices,SpectrAlert Advance can meet virtually any application • Compatible with System Sensor synchronization protocol and requirement,including indoor,outdoor,wet,and dry applications in legacy SpectrAlert products temperatures from—40°F to 151'F. • °a *lect; z de(a settina 15, 15/75.30,75,95, 110, 115, like the entire SpectrAlert Advance line,outdoor horns,strobes, 135, 150. 177,and 185 and horn strobes for wall applications include a variety of features • Automatic selection of 12-or 24-volt operation at 15 and that increase application flexibility and simplify installation.First, 15/75 candela field-selectable settings,including candela,automatic selection of • Rotary switch for horn tone and three volume selections 12-or 24-volt operation,horn tones,and three volume options enable • Horn rated at 88 F dBA at 16 volts installers to easily adapt devices to meet requirements. • Rated from—40°F to 151°F Next,SpectrAlert Advance devices use a universal mounting plate • Universal mounting plate with an onboard shorting spring that for both wall arid ceiling applications. This mounting plate includes tests wiring continuity before devices are installed an onboard shorting spring that ensures wiring continuity before • Plug-in design with minimal intrusion into the back box devices are installed,so installers can verify proper wiring without mounting the devices and exposing them to potential construction • Tamper-resistant construction damage.Once the plates are mounted,all SpectrAlert Advance • Listed for ceiling or wall mounting devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. • Outdoor devices ship with weatherproof plastic back boxes(metal back boxes are available separately)that accommodate in-and- - Agency Listings out wiring for daisy chaining devices.Plastic back boxes feature removable side flanges and improved resistance to saltwater TIM SIGNALING corrosion.Knock-outs located on the back eliminate the need to drill holes for screw-in mounting.Plastic and metal weatherproof back /4 MEA I` , boxes come with -inch top and bottom conduit entries and 3/4-inch • LISTED ® .as 1a r ua 6 s; a roved 12 :cd carr ,,snub knock-outs at the back.A screw-in NPT plug with an 0-ring gasket 4(.I(C.r'tr hC h t: be' O+Y.I APPROVED a„roved �. b s 3.a(°um° ,.e 1..:+,j,17 M. ,z le F 0135-1853,+ ,� , for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn, Strobe,and Horn Strobe Specifications Archil<.. ,,.... gtneer Spedficationi„.. �. �� : moa General SpectrAlert Advance outdoor horns,strobes,and horn strobes shall mount to a weatherproof hack box.A universal mounting plate shall be used for mounting ceiling and wall products.Ttie notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products.when used with the Sync•Circuit'”Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts.Outdoor SpectrAlert Advance products shall operate between-40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95, 110, 115, 135, 150, 177,and 185. - Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UI.. 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options shall be set by a multiple position switch. On four-wire products,the strobe shall he powered independently of the sounder.The horn or horn strobe models shall operate on a coded or non-coded power supply.The horn strobe must he installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Operating Temperature -40°F to 151°F(-40°C to 66'C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' Operating Voltage Rangea 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 2.5"D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"[..x 4,7"W x 1.3"D(142 mm I._x 119 mm W x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions(SA-WBB) 5.7"L x 5.1"W x 2.0"D(145 mm L x 130 mm W x 51 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,5,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. • 000001201 UL Current Draw Data 111-Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Maw(rnA RDAS) 8-175 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max.Cunard Draw(mA RMS),2-Wire Horn Strobe,Standani Candela Range(16-115 Cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 • Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 Ut.Max.Current Draw(rnA MASI 24/freflorrt Strobe,High Candela Range(135-1.85 Cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-temporal Medium 242 259 293 299 Non-lemporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures,listed How inuittan"i StrObe OutPut((MAY': candela ratings must be reduced in accordance with 6-175 16-33 24-Volt Nominal this table. Switch Sound Volts Volts Reverberant Anechoic Strobe Output(o • - Position Pattern dB DC FWR DC FWR DC FWR DC FWR Listed Candela Candela rating at-40'F Temporal High 78 78 84 84 88 88 99 98 15 2 Temporal Medium 74 74 80 80 86 86 96 96 15/75 Do not use below 32°F 3 Temporal Low 71 73 76 76 83 80 94 89 30 4 Non- High 75 44 Temporal 82 82 88 88 93 92 100 100 95 70 5 Non- Medium 78 78 85 85 90 90 98 98 110 110 lernporal 115 115 6 Non- Low 75 75 81 81 88 84 96 92 135 135 Temporal 150 150 7t Coded High 82 82 88 88 93 92 101 101 177 177 8t Coded Medium 78 78 85 85 90 90 97 98 185 185 gt Coded Low 75 75 81 81 88 85 96 92 fSettings 7,8,and 9 are not available on 2-wire horn strobe. 110 SpectrAlert Advance Diagrams _ 4.7" 2.5" _ r _ :‘ ' ''''''' . I ii , _, •r i \ MI) 4:0 /CI,- 0 ii 5.6" � _., Wall-Mount Horn Strobes 7y��� Wall Plastic Weatherproof Back Box ll 4 - - 111 471 1 0 e: ® C. 0 Ihi i1 1 1 I' _-_.ice i IIIWall-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Model '. �e ' �� \moi Wall Horn Strobes :3*7prn Strobe,,—"'—:, d cd.,+ d,00 door p9s4it if` >05t . ; P2RHK*i 2-Wire Horn Strobe,High cd.Red.Outdoor(includes plastic weatherproof back box) P2WK*t 2-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2WHK*1 2-Wire Horn Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe,High cd,Red.Outdoor, 120 V(includes plastic weatherproof back box) Wall Strobes SRK*I Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) SRHK*t. Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) SWK*t Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) SWHK*t Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) Horns HRKF Horn,Red,Outdoor(includes plastic weatherproof back box) Accessories SA-WBB Red,Metal Weatherproof Back Box SA-WBBW White,Metal Weatherproof Back Box Notes: 'Add"-P"to model number for plain housing(no"FIRE'marking on cover),e.g.,F'2RK-F'. t Add"-R"to model number for weatherproof replacement device(no back box included),only for use with weatherproof outdoor flush mounting plate,WTP and WTPW. "Standard cd"refers to strobes that include 15,15/75,30,75.95.110.and 1 15 candela settings."High cd"refers to strobes that include 135.150.177,and 185 i candela settings.When replacing standard outdoor units both the device and back box must be replaced. • 312 Sys r.m c n!. . 3825 Ohio Avenue•St.Charles, IL 60174 Nlod,uI su� r sublar to cla,geeI uI»ticI�I vsh.I •SeoI orn Phone:800-SENSOR2•Fax:630-377-6495 '" "'' . r 7�IId m,: e t"d'' c,. fNl)SO1)Ii IJ • STEM SENSOR �" tti t ,tItI • tttt Selectable-Output Low Frequency a • Sounder and Low Frequency Sounder t R, Strobes for Wall Applications SpectrAlert1 Advance audible visible notification products SPECT . rt are rich with features guaranteed to cut installation times and maximize profits. Features The SpectrAlert Advance series offers the most versatile • 520 Hz±10%square wave tone and easy-to-use line of low frequency sounder and low frequency sounder strobes in the industry.With white and red plastic housings, • Plug-in design with minimal intrusion into the back box dual listed for wail and ceiling mounting,SpectrAlert Advance can • Tamper-resistant construction meet virtually any application requirement. • Field-selectable candela settings on wall units: Tlx:wall mpunt .tequ• • r® few n g 135, 150, 177.and 185 bes',were tib'r• t a ..... . g�> g ?:. • Rotary switch for low frequency sounder tone = ent5:that require a low frequency notification appliance that • Universal mounting plate for wall units operates within frequency range of 520 Hz±10%and is of a square wave tone.Like the entire SpectrAlert Advance product line they • Mounting plate shorting spring checks wiring continuity before include a variety of features that increase their application versatility device installation while simplifying installation.All devices feature plug-in designs • Electrically compatible with legacy SpectrAlert devices with minimal intrusion into the back box,making installations fast • Compatible with MDL3 sync module and foolproof while virtually eliminating costly and time-consuming • Listed for ceiling or wall mounting ground faults. To further simplify installation and protect devices from construction damage,SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring,so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, Agency Listings automatic selection of 12-or 24-volt operation,arid a rotary switch for 520 Hz low frequency sounder tones. SIGNALING ® MEA o' • LISTED APPROVED approved I` 04011;^underl 304/563 VLA452-G5-E 713E105530223 05512`,.60,es; 1125-105550224 SpectrAlert Advance Specifications General SpectrAlert Advance low frequency sounder and low frequency sounder strobes shall mount to a standard 4 x 4 x 11-inch back box,4-inch octagon back box,or double-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products.when used with the Sync•Circuit'"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply.Low Frequency Sounder strobes shall have field-selectable candela settings including 135, 150, 177, arid 185.The field selectable tones will sound within the frequency range of 520 Hz±10%square wave tone and have a permanent marking on the housing that reads"low frequency sounder". Low Frequency Sounder The low frequency sounder shall be a System Sensor SpectrAlert Advance Model listed to UL 464 and shall be approved for fire • protective service.The low frequency sounder and the Sync•CircuitTM MDL3 Module accessory,if used,shall be powered from a notification appliance circuit output and shall operate on a nominal 12 or 24 volts(includes fire alarm panels with built in sync).When used with the Sync•Circuit Module MDL3, 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt rated notification appliance circuit outputs shall operate between 16.5 to 33 volts.If the notification appliances are not UL 9th edition listed with the corresponding panel or power supply being used,then refer to the compatibility listing of the panel to determine maximum devices on a circuit.The low frequency sounder has an option to switch between temporal three pattern,non-temporal(continuous)pattern and coded supply within the frequency range of 520Hz± 10%square wave tone.The low frequency sounder shall operate on a coded or non-coded power supply. Low Frequency Sounder Strobe Combination The low frequency sounder strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The low frequency sounder strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube arid associated lens/reflector system.The sounder shall have an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The low • frequency sounder on low frequency sounder strobe models shall operate on a non-coded power supply.The field selectable tones will sound within the frequency range of 52011z±10%square wave tone. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and low frequency sounder at temporal three.Also,while operating the strobes,the module shall silence the low frequency sounder on low frequency sounder strobe models over a single pair of wires.The module shall mount to a 4.7'6 x 4"/.6 x 21/2-inch back box.The module shall also control two Style Y(class B)circuits or one Style 7(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control The module shall not operate on a coded power supply. Physical/Electrical pe .r�,... ' •>• Standard Operating Temperature 32'°1-to 120°1-(0°C to 43°C) Humidity Range 1010 93%non-condensing Frequency Range 520 Hz± 10% Strobe Flash Rate 1 flash per second Nominal Voltage Low Frequency Sounder Regulated 12 DC/FWR or regulated 24 DC/FWR Nominal Voltage Range Low Frequency Sounder Strobe Regulated 24 VDC/FWR' Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 6.4 inches 1_x 4.7 inches W x 2.5 inches D (162 mm L x 119 mmWx 64 mm D) Sounder Dimensions 5.6 inches L x 4.7 inches W x 1.3 inches D (142mmLx 119 mrn W 33 mm D) Low Frequency Sounder/Strobe with Surface Mount Back Box 6.4 inches L x 4.7 inches W x 4.3 inches D Dimensions(SBBR.SBBW) (162 mm L.x 120 mm W x 108 mm D) Low Frequency Sounder with Surface Mount Back Box Dimensions 5.7 inches L x 4.8 inches W x 3 inches D • (SBBR,SBBW) (145 mm L x 120 mm W x 76 mm D) • Notes: 1,Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. • UL Current Draw Data UL Max,Low Frequency Souncke Current Draw(mA SMS) ' • 8-175 Volts 16-33 Volts Sound Pattern dB DC FWR DC FWR Temporal 3 High 191 262 138 166 • Continuous High 292 384 138 208 Coded High 292 388 153 205 UL Max.Current Ow(rnA FIMS),2-W1nt Low Frequency Sounder Strobe,High Candela Range . 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal 3 277 292 325 344 Temporal 3 296 309 343 351 Continuous 337 362 387 417 Continuous 393 395 432 433 Low Frequency Sounder Tones and Sound Output Data Low Frequency Sounder and LOW Fraquenq Sounder Strobe Output(d}M) 8-17,5 16-33 24-Volt Nominal Volts Volts Reverberant Anechoic Switch Position Sound Pattern DC FWR DC FWR DC FWR DC FWR 1 Temporal 3 76 76 76 76 76 76 86 86 2 Continuous 80 80 80 80 80 80 90 90 3T Coded 80 80 80 80 80 80 90 90 I Sounder ratings provided are for continuous voltage as provided by the NAC • • 0 SpectrAlert Advance Dimensions 141 4.7 in. ----0- 2.5 in. P. 14— 4.7 in. 01 1.3in. = a -----::\ Wff lip • 3n— II I 111/ ,== a MI II M 11 —--______ OH \\ r ___,, 5.6 in. To ,rfil), 6.4 in. \, \, , R ==== === , M , t,..........iim „, .,,:.„.,. --I c-s-_______±_________ y ........„. . i......:.,, _, Wall-mount low frequency sounder strobes Wall-mount low frequency sounder 0 SpectrAlert Advance Ordering Information ,Aggig:;:z.gjgs2u .-7- .j,li,..,,..'--..... ,.;;:.;;:lilii..,.. .:. .Ak.: ..:.., Wall Low Frequency Sounder Strobes P2RH-LF 2-Wire Low Frequency Sounder Strobe,High cd,Red P2WH-LF 2-Wire Low Frequency Sounder Strobe,High cd,White Low Frequency Sounders MO if.;;I:,,;c:,:4,ir.1;w2.:,.i::;,„„94 HW-LF Low Frequency Sounder,White Accessories - SBBR Surface Mount Back Box,Wall,Red , SBBW Surface Mount Back Box,Wall,White TR-HS Trim Ring,Wall,Rod • Notes: "High cif'refers to strobes that include 135,150,177,and 185 candela settings. • 4.. \ SYSTEM 3825 Ohio Avenue•,St.Charles,IL 6017,4, 02r,,,,,„,= 4 SENSOR Phone 800 8"\Ctv)=it re=FnZrfd-31I-643‘) .'''''''''''''-r. ;'"'41')\-‘ ,',';.-‘r:1!'irv":n4'''''''';'''''