Plans (19) Markup Legend SPRINKLER SYMBOL DEFINITION T COLOR/LINETYPE LEGEND 7 T Q T1 \ BLUE LINES=FEED TO FIXTURES(BATH,SHOWER,ETC.). %MBO o Delete Line 0 XXX-XX GREET!LINES= IED TO XT CO(�JPJECTIOL]SHOWER, z } BLACK LINES=SPRINKLER HEAD TO SPRINKLER HEAD. o MAXIMUM SPACING(TYP) §F:.)8 =_= = 1/2"PIPE SIZE C Add Line SPRINKLER MODEL(TYP) '-',1�t o ` HEAD SYMBOL(TYP) =3/4"PIPE SIZE a co.,,,u Add Tee = = 1"PIPE SIZE O u = 1-1/4"PIPE SIZE ,(^,:' `.2L.68 Add Elbow CITY OF TIGARD „,i'' Add Coupling I Approved [viD = "”'w Conditionally Approved [ ] RECEIVE WMaawin.=W3 Add Head -A.1\--�.2\--A.3\- .N 1-W See Letter to:Follow [ ] N Delete Head _ , _ Attached [ 1 JAN 23 2017 _i zY�o o= = MS` aoV- -OO,,�,A, < eo=ri r4 Permit Number: CITY OF TIGARD _" �s°- � Move Head O- -0- 1J ISQ S.W. Si IR-K+ rraI« IV1,# Ill Czs� BUILDING DIVISION y ,z6O Address: _o2zzwR 4-s Notes All revisions mus[be reviewed by Uponor By: .Date I�. �; (l z o N'=-,u o 3=,� Table F002-1 u Moos_z�>��z CZ Zen>.0 ,W___— O0<0S. ,+F_7 z Multipurpose Fire Safety Systems o z z< 'a o w:=44 system insThe tallr ed Residential comb Inat cre ombination with thefety e cold side ofm is a fthe domestic al fire protections potable W m o g¢>.--o o z 3<S water system. Only licensed contractors trained by Uponor can install this a w=z 'F Y¢z¢z t system. y iz�� jai¢386°2¢N-],,� g UWhat to do if Changes are Required -E'.:S"" a6 ',. te°. If any features or obstructions require the addition or deletion of sprinkler 1"AQUAPEX INTERLEVEL 1"AQUAPEX INTERLEVEL N 4< : - ¢ o N s heads,or significant relocation of sprinkler heads,contact the Uponor Design CONNECTIONS FROM SECOND CONNECTIONS FROM FIRST C°5'25--:°-‘2 ,1:.,` '''''±2 `o z F � -> F u' FLOOR TO SECOND FLOOR i'FFzm opo (888.594.7726. _ Department to determine if observed changes require a redesign FLOOR 4 MOST HYDRAULICALLY REMOTE HEADS /�� \ \! A _�� \ I p.� !> � < Q FI pJpz p�0 HEAD# GPM PRESSURE RE 'D AT STREET �I i _ ._�� A = ,00mi- xm- z 1 HEAD H.4 11 40.9 /I'll \A \ / V \ ,„ ,[s `zz� 2 HEAD H.8&H.7 20.02 59.16 - � 'i V 0 iz> .a d w \\ N ,RC-RESLF-14 / \ \ 0 R SLF /I 111 4 \ ,_'_,.� 9 1 1st Floor RC ESLF-14/ ai ( \ V '�' RC-RL .14 . ., l;' ._ �� A - 6 2nd Floor 8 3rd Floor �• I 1 4 r 5.1 MAIN SHUTOFF \ - -- i-- - N VALVE LOCATION 16 TOTAL — , ' \ ® 14 KSE3.7,�16d2Fl°RC-RESLrfce,Maximum Spacinw K3.7 g 4ax 4oncealed Pendent SS8261 / t, 1 A - I�l' \ �l \ Garae pN Model RC-RESLFIT LowFlow K3.7 Residential Concealed Pendent SS8261 At �� e �� O �II �- A \ T - - l+ V II T OFFICE COPY Sprinkler head demand. 10 m @ 7.3 \ T 22 I 011 \ 1 n y !N RC RESLF 14 . SE 7U od C ® - - - 1 K=3.7, 175E°,7/16 Orifice,Maximum Spacing 14'x14' r \ O RC-RESLF-14-175 Sprinkler head demand: 11 gpm @ 8.8 1,—.; at 1 �i A . "� -I \ I / I \ _ I 1"AquaPEX TO SYSTEM r l I 1� A M.25� /4 '� Meth. .> o 1' .18 111, F.7 r F.6 I . F:I h.I =z rz2 -p I a._ a�, .,,..11, m f�i RC-RES�-14 ,���c� a ill I'l tv„,.�A � . ,r. wog/ t. �II f�C-RStL 1 1�-',I y/ /14C,-R t�F- 4 \ RCS -s-EF-14'i 14 7 I T.)34 , " __ ` m H ATTENTION:THE DESIGN FLOW EXCEEDS THE MAXIMUM RATED FLOW ALLOWED BY THE � 4- I� y tI` I METER MANUFACTURER.THE PRESSURE LOSS TABLE FROM NFPA 13D 2013 EDITION 10.4.3(a) 6 - d, I h' J o m v i1T � ': 1 '' ,r i a K F- HAS BEEN USED TO DETERMINE THE PRESSURE LOSS FOR THE DESIGN FLOW USED.A FULL q RE i �, 21 _ 29 r �1 3 T:3512 FLOW TEST CONSISTING OF THE TWO MOST HYDRAULICALLY DEMANDING SPRINKLERS PLUS - �` T.A�„ $.,- �, w m °z AN ADDITIONAL FLOW OF 5 GPM FROM DOMESTIC FIXTURES SHALL BE PERFORMED TO �, Rc � F 4 T• I I R_ Ec I n VERIFY SYSTEM PERFORMANCE. ° I T i Y kV ' I o w z a EXTERIOR WALL T . ' Q o ELEV-108' ,.y , 15 �' <v .a a STATIC: 62psi ,I T.3 F �, a a z o r T.30 , QHPI z'gs� w RESIDUAL: 57psi �. hi +�I .3 ' I I: ;(-- -IY � FF I--I N 0 o a a z o 0 FLOW RATE: 3650gpm / 1"AquaPEX II I ��� ®� �_ / 4 o / s 7 4,3 s�TO SYSTEM I RC-RESLF-14 v I .�, 'li `�i F-14 ,. �a•,1�. 'J ..�1 -y �fii� SII rl w 0 RC-RES TO HOT WATER HEATER d �. �1I "_ s_li> Ill r�� � � ", i �� z EH s r' RC ESh 1 /` \ \ _ - , ,_ z Q o 0 0 I--� Iowe 1"FULL PORTf E �1 'rid ' _ l m d 1 z tl FaJF�� BALL VALVE w 7. � I� I— I s . 46 > Qw w= ® ® 1 iia >i ' II' 1'-1 /V9 =m =A LL ELEV=100' ELEV=100' / ce mb--i G3o5 ¢ � w=g; F 5/8"METER /// ///////" 3 THIRD FLOOR 2 SECOND FLOOR FIRST FLOOR ��_��a 35'OF 120'OF SHEET DESCRIPTION 1"COPPER-K 1-1/4"AquaPEX F100 ;' 1/4" /^n = 11-0" F100 1/4" /^n _ 11-0" F100 ' 1/4" /^n = l I_On ALL LEVELS 4 WATER SERVICE DETAIL 5 0 5 15 SHEET NUMBER F100; NTS 14 - © UPONOR - CONFIDENTIAL , Markup Legend COLOR/LINETYPE LEGEND `_ z I _ �� - i BLUE LINES=FEED TO FIXTURES(BATH,SHOWER,ETC.). o � � �� 0XXX-XX ��o� GREEN LINES= IfJTERLEVEL CONNECTIONS/SUPPLY. ' o Delete Line 1PRIN l ,/„� 4 BLACK LINES SPRINKLER HEAD TO SPRINKLER HEAD. MAXIMUM SPACING(TYP) /�I'� '� j/�° — >^O q�q�j � � /�� —1/2” LEE W 3 LL's a i/��r / � �/, ' U N tWJI z / /� / ! ( k'',.;', °- Add a:N za CL Add Elbow a �l, @@ � i�� � .--2-) !;,--[,',c'4-5,41' Add Cou lin -I C q% ✓4 Y f>/� �;� ''' --_,',-...7,-. a v°'i 3 Add Head Al :11 -�.3- .,,174p;� - o�,�W3 Delete Head - n J - 3%�/ / /� _oi ¢¢z1 � �x Move Head -0- \O- I'._-.� �...� ,�:y;for/� /K,"447.,)",.% �o�'/�� 1�: __ �',, z .. >���z¢oma 'L1---(;41, I �� - z.., Note:All revisions must be reviewed by Uponor ¢ i4' tl ) o• ns z35¢ Table F002-1 t i+I I , _ �I I, 1, El c �o � urz oo¢�m� �Fdz-z Multipurpose Fire Safety Systems o . ¢o o The Uponor Residential Fire SafetySystem is a residential fire protections ,— z z o o-' r" system installed in combination with the cold ode of the domestic potable 4 KEY PLAN N> ¢_ = `LL water system. Only licensed contractors trained by Uponor can install this a z o: ¢ ¢z 1"AQUAPEX INTERLEVEL a i z¢g 0 ¢ o system. _ i _� w¢Fo F�¢>3_ F101� l�'Tc CONNECTIONS FROM FIRST U-iz u- Ka4¢j Fy.EK What to do if Changes are Required NTS I J TO SECOND FLOOR 0 y y u'1'�'o z Ei:,-,,.-,,'..),- FLOOR If any features or obstructions require the addition or deletion of spookier -- N ¢ d o ¢¢o K' y u heads,or significant relocation of spookier heads,contact the Uponor Design 1'AQUAPEX INTERLEVEL z o CONNECTIONS FROM SECOND Z ¢ o 0 D epartment to determine If observed changes require a redesign /I \ y z 0 p¢o m o B 8.594.7726 9 91 ��/ I z �,a o z z FLOOR TO THIRD FLOOR } I 7 0�'- F ¢ ¢ ....4__. r /I Y --1.� / 11 I \\ _� / _ _2r-r .._- • m0�_VYd>Q O �� �� z I Al c >▪ � apo / RR�- �ESLF 14 ii I '� z / „— ` / / �� - 1 Aqua PEX TO SYSTEM �" 00 R RE �F 1fi N,/ I H.9 \ /1.10 1 M oSHUTOvFF / r I', Hj O 1 RC RESL 14 � 1_f f 1 \ \1 �IN Y / / \ \ �T .,r.,.E RESLF-14 / 1I �. j 1, T.17, �z/ / / ;1 I A_ mi. A ;.. e r� IL II I a �I, ,, ,_i 1,,,, 4.„-:,,„ L., 04-44-1� 11 I 'NA ii ;1 �� 't V 1 • 1.T.2 : 1 ` F7 I ea�I � T� O I t,�= � 6 V -- I , , k I I 1 RC RESLF 14 � f :3 wA. °=0 F -F---14,z ' f1ESLP14 51 11 f ,I ;. III 4 r ���1 z ic a°I 1 - S f°^ r'','' v FC'-' �> r i.l "' -R. -.i� .I, I .w.' w�l' 1 �/ �I 1 _ comm I . 'v.,' � I � I h I h I' � n �t-F 4 Fkip w F 4 T.2 1 � �� �, � Lam H 1� T�37 M 41T (Y 1-1 oo�s=� w ,, F '," '17"4=''' �( L. I Z uuuaamZOo RGR � F.2 n H.F- �, f#ESLF 14 , I,. r `'I F.4 _,-a) RC RESLF 14� I RC�& �' fi ,--I w - r Sr_r r ht_, f i; 1� III •',•° � �. • Y I U 1, LF 14 �_' ' �� �� L � � � oz0 F mwf�!� 1 (- 1-i 1 , k �I I fi '_ m��� w E of i ••""_2'';? ,,_ ` ,i- I H z'o LL o o F wF w 3 THIRD FLOOR 2 SECOND FLOOR FIRST FLOOR SHEET DESCRIPTION z ALL LEVELS-MIRROR F101 " F101) F101 1/4" = 1 1/4" = 1 -0 1/4" = 11-0" -0 SHEET NUMBER MIRROR 5 D S 15 © UPONOR - CONFIDENTIAL F101 Senju RC-RES:Open Web Truss/T]I Construction Insulation Recommendations A uaSAFETm GENERAL NOTES: In areas subject to freezing,care should be taken in unheated attic spaces See General Notes 8.2.5.7 for Architectural `1 ProPEX LF Brass Fire to cover Uponor AquaPEX tubing completely with insulation. Insulation Feature Requirements Sprinkler Adapter Tee should follow the guidelines of the insulation manufacturer. See Uponor _ %mom li. 1. THIS SYSTEM IS DESIGNED AS PER NFPA 13D 2016 EDITION ASA RESIDENTIAL MULTIPURPOSE SYSTEM Fire Sprinkler Adapter z Blocking Maybe Document"Uponor AquaSAFE Attic Insulation Guidlines"for attic O SECTION 3.3.11.3. �rc --- -- Pash-an Nut w u Required.If installation guidelines(Provided in Contractors Documents package or online ` / o 2. UPONOR COMPANY RESERVES THE EXCLUSIVE RIGHTS TO ALL DETAILS AND DRAWINGS AS SHOWN ON Blocking is Used, �,-1 r 1%4"Min. at www.Uponorpro.com). ` I- I / O Q N o THIS SHEET. THESE DETAILS AND DRAWINGS ARE PROPRIETARY INFORMATION OF UPONOR COMPANY AND Use The 2 Top 1 Max. w a Screw Holes. �^ / Bottom of Mounting Extreme Temperature Installations Planter Box Window,Bay Window or Similar Feature. 5 O8 UNAUTHORIZED USE MAY BE SUBJECT TO PROSECUTION TO THE FULL EXTENT OF THE LAW. P _ Bracket m Face of Truss If no additinal floor area is created No Additional Sprinkler is Required. m G u AquaSAFE Residential Fire Safety systems are often installed in attics or a o,w a 3. THE DESIGN OF THIS SYSTEM IS DICTATED BY SPECIFIC CEILING HEIGHTS AND ROOM SIZES. IT IS THE Fire Sprinkler Adapter-\ - -/ 7 other areas exposed to temperature extremes of heat and/or cold. Follow 8'-0"or less L O .%ry u S, RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO ENSURE THAT THE CONDITIONS SHOWN ON THESE Mounting Bracket i ,L�,_/J i the recommended extreme weather installation instructions to isolate and / zf W 3 LL 5 PLANS ARE EXACTLY AS THEY EXIST IN THE FIELD. DEVIATIONS FROM THE DESIGN MAY CAUSE THE t O SYSTEM TO BE UNABLE TO CONTROL A FIRE.IF THE BUILDING CONSTRUCTION DIFFERS FROM THE FIRE protect system components from extreme temperatures. Because this RC-RES-16 SPRINKLER PLAN,CONTACT THE SYSTEM DESIGNER IMMEDIATELY. 3-#10 x 1 1/2" 'tY - system higo delivers domdstih cold water t the utplumbing with uae, 9'-0"or less0 ,,•'1,:,iD z S �- Uponor highly recommends that you protect the tubing with adequate /-- - � :��� Full Course I I w insulation in warm weather areas to minimize heating of the cold water m v�^ 4. THIS SYSTEM AND THE ACCOMPANYING HYDRAULIC CALCULATIONS ARE DESIGNED IN COMPLIANCE WITH Thread Screws supply. = '"\ - Z v 4 o o - NFPA 13D 2016 EDITION. In Bottom Holes _ o .64 3 17.. ° v `o v \ Installation methods include,but are not limited to: C. In„,oe a ro S. "STAND-ALONE"OR"MULTIPURPOSE,WET PIPE"SYSTEMS ARE NOT PERMITTED TO USE ANTI-FREEZE. _ \ I °\ I / \ -Y w ~_ • Tenting over the fire sprinkler piping. O m 3 • Lead-Free Flat Additional layers of batt insulation. If additional floor area is created.Cannot exceed 18 ft',be more than 2'-0" 6. MODIFICATIONS ARE PROHIBITED.SPRINKLERS THAT HAVE BEEN PAINTED,CAULKED,MODIFIED OR - ,ru r. •. ..-3 • Y Concealer Senju L Concealed Flat • Increased depth of blown-in insulation. dee more than 9'-0"wide and be with in the coverage area of the o DAMAGED MUST BE REPLACED. P P, 9 z < y 5 Sprinkler Head LL ¢ i Cover Plate sprinkler.No Additional Sprinkler is Required. z'�+ v�+�_� y 7. WATER SHUT OFF VALVE IS NOT PERMITTED THAT ISOLATES THE SPRINKLER SYSTEM. Caution: If you will be installing spray foam insulation,make sure to ..S,'.', z<"o z 2.-o cr 1 protect all components during application.Consult with the spray foam ,2?,-c F- s. OWNERS MANUAL MUST BE PROVIDED TO THE OWNER. Senju RC RES:Traditional Wood Framing Construction NFPA 13D Table 7.5.5.3 Distances From d o °c°w manufacturer[o ensure compatibility with all products before application. - � ., o z¢o z P Y P PP 2;, FC�+wOVY< Heat Sources T <o,,sa5 9. AT THE MAIN SHUT OFF VALVE,A TAG OR A SIGN STATING THE FOLLOWING IS REQUIRED;"WARNING,THE u x o_E x z z 4 w i WATER SYSTEM FOR THIS HOME SUPPLIES FIRE SPRINKLERS THAT REQUIRE CERTAIN FLOWS AND Consultation with local building officials is encouraged to ensure compliance --°: r-.i s r o PRESSURES TO FIGHT A FIRE.DEVICES THAT RESTRICT THE FLOW OR DECREASE THE PRESSURE OR ProPEX If Brass Fire with local building codes. z o r°u-8 u z ce 3-, Ordinary Intermediate AUTOMATICALLY SHUT OFF THE WATER TO THE FIRE SPRINKLER SYSTEM,SUCH AS WATER SOFTENERS, Sprinkler Adapter Tee • Fire Sprinkler Adapter ry 2 e c o 4.z7,,:,U F z FILTRATION SYSTEMS AND AUTOMATIC SHUT OFF VALVES,SHALL NOT BE ADDED TO THIS SYSTEM p pHeat Source Temp. Temp. z z n;o .-L J F-z s Push-on Nut o e.c 135°-170° 175°-225° z-., o<Qoc ,..F WITHOUT REVIEW OF THE FIRE SPRINKLER SYSTEM BY A FIRE PROTECTION SPECIALIST.DO NOT REMOVE 'I" PEX -- d 0,z-,O w°Z C C = THIS SIGN". Bending Tubing Side of Fireplace 36" 12" z o_o.: Fire S rip der Adapter- I , - 2' 9 Bendtsupports are available xle for 3/8",1/2",3/4"and 1"Uponor AquaPEX36" W Y w o f,o.4 . ,.:.. -,9° z 3¢? 11/q'Min. The minimum bend radius of Uponor PEX tubing in any direction is six times 1 Front of Fireplace 60 m❑�soPzz< " 1/'Max. Bethoutside diameter(6 x ef OD). Wood BurningStove 42" 12" °¢z .4 < 10. ALL INTERIOR PIPING TO BE UPONOR"Aq ua PEX®"UNLESS NOTED. f Bottom cf=ace of n ¢= P PP q t"t O -.zzF <--r 11. UPONOR"AquaPEX"TUBING TO BE SUPPORTED PER NFPA 13D AND MANUFACTURER'S RECOMMENDATIONS. Mounting Bracket J • Bracket to-ace of Truss tubing to facilitate 90-degree rigid bends. Kitchen Range 18" 9" J _u o o_2 z Q 0 o Wall Oven 18" 9" U azT-w¢m�4,4y_a'c 12. MINIMUM SPACING BETWEEN SPRINKLERS IS 8'-0" REFER TO SPACING CHARTS FOR MAXIMUM SPACING 2-#10 x 1 1/2" 0 ® Recommended Tubing Length Between Fittings Hot Air Flues 18" 9" w`^u o �_u z o <h,-, BETWEEN SPRINKLERS AND FROM WALLS.SPRINKLER HEAD MANUFACTURERS MAY HAVE MORE Full Course j } 18" 9" O m<°�'d ¢¢N_.o w u RESTRICTIVE SPACING LIMITATIONS. Thread Screws I I Fitting Size Minimum Tubing Length Uninsulated Heat Ducts z w o z c'o o x.N Uninsulated Hot Water Pipes 12" 6" ¢,-. .-....,,,, _w In Top Holes 3/8"ProPEX Fitting 2^ x'r 0 o ,, 8 p z o 13. SPRINKLERS ARE NOT NECESSARILY CENTERED IN ROOMS DUE TO LIGHT FIXTURES OR OTHER CEILING Side of Hot Air Diffuser 24" 12" v 2 N MOUNTED OBSTRUCTIONS. 1/2"ProPEX Fitting 2 1/2" --,,,q4,,-4,--<;== .da o w-,4 S z--„z • Front of Hot Air Diffuser 36" 18" 3 0 0 e a 14. THE PLUMBING TIE IN CONNECTIONS ARE SCHEMATIC IN NATURE AND CAN BE INSTALLED OFF THE 3/4"Pr0PEX Fitting 3 1/2" Hot Water Heater 6" 3" .4u < o F 'o 2 SPRINKLER LOOP ANYWHERE BETWEEN SPRINKLER TO SPRINKLER CONNECTION. Lead-Free Flat \• _ 1"ProPEX Fittin 4 1 2" Furnace 6" 3" c`>w z 0 ,0_,7....e,,-.c 5 zcc, Concealed SenJu q / wo 4 cem o`u e r Concealed Flat ,zo20F2¢a_ 2_w Sprinkler Head 50W-250W Light Fixture 6" 3" s - 15. THIS SUGGESTED LAYOUT IS BASED UPON INFORMATION PROVIDED BY OTHERS. CHANGES IN Cover Plate 1 1/4'ProPEX Fitting 5 1/2' 9 -r''>,z u,4x LL p s- a CONSTRUCTION OR FIELD CONDITIONS MAY OCCUR WHICH MAY REQUIRE CHANGES TO THE LAYOUT. IT IS ---- 250W-499W Light Fixture 12" 6" w 2 m 5 3 5 N F z c`6 s THE RESPONSIBILITY OF THE INSTALLER TO NOTIFY UPONOR TECHNICAL SERVICES OF SUCH CHANGES. st z%'>-z>w "28 \ oouo< oz xww w Exposed Installation Requirements. c"Ns a 16. NFPA 13D OBSTRUCTIONS TO RESIDENTIAL SPRINKLERS • 8.2.5.6* SHADOW AREAS SHALL BE PERMITTED IN THE PROTECTION AREA OF A SPRINKLER AS LONG AS Uponor Aqua PEX'"'tubing(white)and ProPEXT"'EP Fittings and ProPEXT" THE CUMULATIVE DRY AREAS DO NOT EXCEED 15 FT'PER SPRINKLER. Brass Fittings are approved for exposed installation where the following • 8.2.5.7 SMALL AREAS CREATED BY ARCHITECTURAL FEATURES,SUCH AS PLANTER BOX WINDOWS,BAY conditions are met.(UL 1821 Approved) WINDOWS,AND SIMILAR FEATURES,SHALL BE EVALUATED AS FOLLOWS: (1)WHERE NO ADDITIONAL FLOOR AREA IS CREATED BY THE ARCHITECTURAL FEATURE,NO Exposed Wood Joist Ceiling Assemblies. ' /� , 10, ADDITIONAL SPRINKLER PROTECTION IS REQUIRED. 1. Joists are of dimensional lumber,engineered wood,wood I-joist or open ^' m (2)WHERE ADDITIONAL FLOOR AREA IS CREATED BY AN ARCHITECTURAL FEATURE,NO ADDITIONAL web wood joists. m SPRINKLER PROTECTION IS REQUIRED,PROVIDED ALL OF THE FOLLOWING CONDITIONS ARE MET; 2. Joist are of depths from 6-16 inches(152-204 mm). (a)THE FLOOR AREA SHALL NOT EXCEED 18 FT'(1.7 Mk) 3. Joist are of spacing from 12-24 inches(305-610 mm)on center. 0❑ (b)THE FLOOR AREA SHALL NOT BE GREATER THAN 2 FT IN DEPTH AT THE DEEPEST POINT OF 4. Joists can be exposed after installation. \ 1.55" \ THE ARCHITECTURAL FEATURE TO THE PLANE OF THE PRIMARY WALL WHERE MEASURED 5. Metal pipe hangers spaced at maximum 24 inches(610 mm)on center 1.66" ALONG THE FINISHED FLOOR. are used. (c)THE FLOOR SHALL NOT BE GREATER THAN 9FT IN LENGTH WHERE MEASURED ALONG THE 6. Listed residential automatic sprinklers of maximum activation '" -4n Hanger 1" Hanger PLANE OF THE PRIMARY WALL. temperature rating of 155°F(684C). (d)MEASURED FROM THE DEEPEST POINT OF THE ARCHITECTURAL FEATURE TO THE SPRINKLER SHALL NOT EXCEED THE MAXIMUM LISTED SPACING OF THE SPRINKLER. Tubing Support Spacing: (3)THE HYDRAULIC DESIGN SHALL NOT BE REQUIRED TO CONSIDER THE AREA CREATED BY THE Metal Tubing Support. (Anchor AquaPEX Tubing Securely Enough to Support the Tubing,Ye[Relaxed 1. Metal tubing supports designed for plastic tubing shall be used. Enough to Allow the Tubing to Expand and Contract) ARCHITECTURAL FEATURE. 2. Do not use supports that will damage the tubing.Inspect metal supports for sharp edges. 1. Along Horizontal Runs,Install Supports Every 32",if Horizontal Runs are 17. NFPA 13D 8.3 LOCATION OF SPRINKLERS. 3. Do not ri idl anchor U onor A uaPEXT''Wbin with su orts.Allow • 8.3.1 SPRINKLERS SHALL BE INSTALLED IN ALL AREAS EXCEPT WHERE OMISSION IS PERMITTED BY 8.3.2 rigidly P q 9 pp Continuously Supported,Place Tubing Supports at Six-Foot Intervals. enough tubing for freedom of movement to expand and contra R. THROUGH 8.3.8. 2. Along Vertical Runs,Install Supports Every Four to Five Feet,at Each • 8.3.2 SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55 FT'(5.1 M')AND LESS Floor and at a Mid-story Guide. z • 8.3.3 SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS,LINEN CLOSETS,AND PANTRIES THAT 2 MEET ALL OF THE FOLLOWING CONDITIONS: In-line Flow Test �i o (1)THE AREA OF THE SPACE DOES NOT EXCEED 24 FT'(2.2 M'). The In-line Flow Test can be constructed on site. It performs a flow test to 22 2 2 _ (2)THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE Standard Riser Assembly ❑ MATERIALS AS DEFINED IN NFPA 220,STANDARD ON TYPES OF BUILDING CONSTRUCTION. ensure proper system operation and flow(see Figure F001-8). :, In amulti-purpose system a single control valve controls both domestic and u~°' • 8.3.4* SPRINKLERS SHALL NOT BE REQUIRED IN GARAGES,OPEN ATTACHED PORCHES,CARPORTS,AND fire safety needs. a w^ m II > SIMILAR STRUCTURES c'c'' ri O C • 8.3.5 SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS WITH OR WITHOUT STORAGE,PENTHOUSE % Uponor Aqua PEX a 0 o�F N- w EQUIPMENT ROOMS,ELEVATOR MACHINE ROOMS,CONCEALED SPACES DEDICATED EXCLUSIVELY TO AND Tubing % r CONTAINING ONLY DWELLING UNIT VENTILATION EQUIPMENT,FLOOR/CEILING SPACES,ELEVATOR SHAFTS, / W �7•� w 0 CRAWL SPACES,AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING ` W z PURPOSES. j ) ) a.9 F-U 0 J • 8.3.5.1 SUCH SPACES THAT CONTAIN FUEL-FIRED EQUIPMENT SHALL ALSO COMPLY WITH 8.3.5.1.1 OR v a 8.3.5.1.2. z u u a m • 8.3.5.1.1 WHERE THE FUEL-FIRED EQUIPMENT IS ABOVE ALL OF THE OCCUPIED AREAS OF THE DWELLING -------- j - j Q H (V'� 6 z a a o w U w UNIT,NO SPRINKLER PROTECTION SHALL BE REQUIRED IN THE CONCEALED SPACE. - H O o 0 0 i el 0 • 8.3.5.1.2 WHERE FUEL-FIRED EQUIPMENT IS BELOW OR ON THE SAME LEVEL AS OCCUPIED AREAS OF THE �� I N u 8 u¢a ut 8 to Male Threaded Coupling ProPEX Fire p DWELLING UNIT,AT LEAST ONE QUICKRESPONSEEINTERMEDIATESEPARATING TEMPERATURE SPRINKLER SHALL BE ("\J INSTALLED ABOVE THE EQUIPMENT OR AT THE WALL SEPARATING THE SPACE WITH THE FUEL-FIRED Sprinkler Adapter � � � E. EQUIPMENT FROM THE OCCUPIED SPACE. L,' o • 8.3.6 SPRINKLERS SHALL NOT BE REQUIRED IN COVERED,UNHEATED PROJECTIONS OF THE BUILDING AT 1"Ball Valve on To Hot Water Heater Male Threaded Coupling -- Li 1 \ > ENTRANCES/EXITS AS LONG AS THE DWELLING UNIT HAS ANOTHER MEANS OF EGRESS. " - Female Threaded IT-I /�I 0 0 • 8.3.7 SPRINKLERS SHALL NOT BE REQUIRED FOR CEILING POCKETS THAT MEET THE FOLLOWING _ E -/ \ Tee with Water H r+ G D m CONDITIONS: v _ e (rt O o U- (1)THE TOTAL VOLUME OF ALL UNPROTECTED CEILING POCKETS IN A COMPARTMENT DOES NOT EXCEED Pressure) a `•J Sprinkler Orifice (Optional) o 100 Fl,(2.83 Ma). - II /"�� z o w s 2 THE ENTIRE FLOOR UNDER THE UNPROTECTED CEILING POCKET IS PROTECTED BY THE SPRINKLERS v LL m a M d ( ) AT THE LOWER CEILING ELEVATION. c -- (3)*THE INTERIOR FINISH OF THE UNPROTECTED CEILING POCKET EXCLUDING DECORATIVE v 71 L __ Uponor Warning Signs FlowToTest W Q TREATMENTS IS NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE MATERIAL. m performance,ensure the system should provides enough a flow water for propertest fire sprinkler °' f-,,i,,, `" you conduct a verification test. \ .. S° (4)SKYLIGHTS NOT EXCEEDING 32 FT'(2.97 M')SHALL BE PERMITTED TO HAVE A PLASTIC COVER. _ 1-' / H w w • 8.3.8 SPRINKLERS SHALL NOT BE REQUIRED IN CLOSETS IN GARAGES AND EXTERIOR CLOSETS o Note: The NFPA 13D Installation Standard does not require flow 11 ' (l I y m s r0 o (REGARDLESS OF SIZE)LOCATED ON EXTERIOR BALCONIES,EXTERIOR BREEZEWAYS/CORRIDORS,OR - .. verification. M vv °'0 " m ACCESSED FROM OUTDOORS WHERE THE CLOSET DOES NOT HAVE DOORS OR UNPROTECTED ••••-• 1� 5 Y 0 3 a Main Fire SprinklerI 3`,,'Nr.,,,,' LL a PENETRATIONS DIRECTLY INTO THE DWELLING UNIT. _ - Before performing a flow verification test,confirm the water pressures by - • Shut-off Valve o G at a o.-, • 8.3.9 SPRINKLERS SHALL BE INSTALLED IN ANY CLOSET USED FOR HEATING AND/OR AIR-CONDITIONING z - contacting the Water and Sewer Department of your local city. Ensure the a p u z EQUIPMENT,WASHERS AND/OR DRYERS,OR WATER HEATERS EXCEPT AS ALLOWED BY 8.3.8. available water pressure matches the pressure used in the system design. Note: The sprinkler plan indicates the most hydraulically remote sprinkler SHEET DESCRIPTION • 9.1.1*WET PIPEE SYSTEMS IN AREAS ABOVE 40°F. A WET PIPE SYSTEM SHALL BE PERMITTED TO BE TO BE ,'E' ,� 18. INSULATION GUIDELINES PER NFPA 13D. (or pair of sprinklers). For test requirements on other sprinklers,consult GENERAL NOTES&DETAILS USED WHERE ALL PIPING IS INSTALLED IN AREAS MAINTAINED ABOVE 40°F,INCLUDING AREAS PROPERLY a your local code. INSULATED TO MAINTAIN 400F. •• A.9.1.1 IN AREAS SUBJECT TO FREEZING,CARE SHOULD BE TAKEN IN UNHEATED ATTIC SPACES TO Note: It is a good idea to notify the fire inspector at least 24 hours prior to COVER SPRINKLER PIPING COMPLETELY WITH INSULATION. INSTALLATION SHOULD FOLLOW THE performing a flow verification test. This may speed up the inspection GUIDELINES OF THE INSULATION MANUFACTURER.FIGURE A.9.1.1(A)THROUGH FIGURE A.9.1.1(F) process and eliminate the need to repeat the test for the inspector. SHEET NUMBER SHOW SEVERAL METHODS THAT CAN BE CONSIDERED. THESE ARE FOR ILLUSTRATIVE PURPOSES ONLY. CONSULTATION WITH THE GENERAL CONTRACTOR AND/OR OWNER IS RECOMMENDED TO ENSURE Note: See"AquaSAFE Flow Test Instruction Sheet"(Provided in PROPER METHODS AND MATERIALS ARE USED TO MAKE SURE 40°F WILL BE MAINTAINED. Contractors Documents package or online at www.Uponorpro.com)for more information on Flow Test Setup,Assembly,Performing the Test and Troubleshooting. If there are any questions please contact Uponor. © UPONOR - CONFIDENTIAL F001 FOR OFFICE USE ONLY—SITE ADDRESS: This form is recognized by most building departments in the Tri-County area for transmitting information. Please complete this form when submitting information for plan review responses and revisions. This form and the information it provides helps the review process and response to your project. , City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT Transmittal Letter T i ti.tµl T) 13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.718.2439 • www.tigard-or.gov TO: City of Tigard DATE RECEIVED: DEPT: BUILDING DIVISION RECEIVED JAN 232017 FROM: Gavin Thomes B CITYIOF DIVISION COMPANY: Alliance Plumbing PHONE: (503) 492-3490 By. RE: 13750 SW Silent Fox Terrace MST2016-00228 (Site Address) (Permit Number) West River Terrace - Lot 16 (Project name or subdivision name and lot number) ATTACHED ARE THE FOLLOWING ITEMS: Copies: Description: Copies: Description: Additional set(s) of plans. 2 Revisions: Fire Sprinkler Plans Cross section(s) and details. Wall bracing and/or lateral analysis. Floor/roof framing. Basement and retaining walls. Beam calculations. Engineer's calculations. Other(explain): REMARKS: Complete re-work of the multipurpose fire sprinkler design to adjust for lower than expected water pressure. FOR OFFICE USE ONLY Routed to Permit Technician: Date: Initials: L' Fees Due: ❑ Yes ❑ No Fee Description: Amount Due: �e�rsP Y42- � � ;tnklur Dtwhs $ 45 ,civ $ $ $ Special Instructions: Reprint Permit(per PE): ❑ Yes o one Applicant Notified: /97,./6-"L:- Date: L-7 /i.— „2//7 nitials: .s r, " I:\Building\Forms\TransmittalLetter-Revisions.doc 05/25/2012