Loading...
Plans (6) ,ei► 1 Markup Legend SPRINKLER SYMBOL DEFINITION ' q COLOR/LINETYPE LEGEND S _10,.1\11 BLUE LINES=FEED TO FIXTURES(BATH,SHOWER,ETC.). % o Delete Line ®XXX XX GREEN LINES=INTERLEVEL CONNECTIONS/SUPPLY. O w u BLACK LINES=SPRINKLER HEAD TO SPRINKLER HEAD. MAXIMUM SPACING(TYP) -' O Add Line — — SPRINKLER MODEL(TYP) = 1/2"PIPE SIZE >M HEAD SYMBOL(TYP) —oma =3/4"PIPE SIZE s O Gdu • = 1"PIPE SIZE O a u m Add Tee CITY OF TIGARD �., = 1-1/4"PIPE SIZE v,i S '' �tLLNo Add ElbowL Approved 0. z :N �° Conditionally Approved [ z's r,w 3 �p�o3 Add Coupling See Letter to: Follow Add Head -A.1 A.2-- 3 Y W 0 0 o RECEIVED if! 13 Attached o��w s , r Permit Number: MS i -. .1 - C. I.� '' -,..,..4. Delete Head JAN 2 3 2017 ¢ Address: is 1`�I -).4...4. -) It,k.-+' '' o= oo- r r }-c �TYYti�cr �c �r '=Y � } Move Head �— (� � ��� u5 J.N�o�° � 3 Date: =sLz�><nyo } Note:All revisions must be reviewed by Uponor CITY OF TIGARD ,w o 2 o=z z ,,-,“,,-A Table be revs ~o¢ w~-¢LL.LL-o BUILDING DIVISION =M z83=z Multipurpose Fire Safety Systems z >o -'-=- oo¢o w, oz o<�¢¢oym��o The Uponor Residential Fire Safety System is a residential fire protections 9_,..,._m00....-g, o z system installed in combination with the cold side of the domestic potable water system. Only licensed contractors trained by Uponor can install this 1"AQUAPEX INTERLEVEL W a n> z 3 R CONNECTIONS FROM SECOND 1"AQUAPEX INTERLEVEL .+ o¢d z z�'�'¢ d system. a o-2¢,z¢a°� FLOOR TO THIRD FLOOR CONNECTIONS FROM FIRST Q i.EF,,z z"o o -v,>3 What to do if Changes are Required J ��r���� ¢�z y 4 FLOOR TO SECOND FLOOR ,,zy" � `wN Jd�,F If any features or obstructions require the addition or deletion of sprinkler S.1 MAIN SHUTOFF V ¢_: ¢ heads,or significant relocation of spookier heads,contact the Uponor Design \� A \'\ VALVE LOCATION 1 q"AquaPEX TO SYSTEM „.y w i o z o° ¢='„-, Department to determine if observed changes require a redesign o z z- ,4 (860.5947726). // Il - i.. x o o MOST HYDRAULICALLY REMOTE HEADS t � ��__ r \\\� \ fico ° o,'ouoo HEAD# GPM PRESSURE REQ'D AT STREET a \ I _',I ._. �� r � V� L o o °Y p> ° > - 1 HEAD H.3 10 37.08 6,12 6:1 1' / A �� � J8zz 2 HEAD H.3&H.4 20.04 53.01 `�rFPiTCH'PI/ \ i� t, l 1 ! NGar 7r-2_1-',.-\; �2<so zyz"a RGRESLF 4 y I \ 1 .R y F 4 C RES f�14 \ �\ , L- ,- t a� ° r" H.3k n , RSL 14-- ,_ \ ., Lyr% FA- - I �� �` . - " - SN 3 1st Floor 1 I .SII -` 'I `�/ \ I? \ ' .r 18 spaFioo� Ifst / droc� I n/ '� I� \ T— ��- i., �� ttt 22 TOTAL l N I IA � A7 ' — —,-yn�N � � II \ H � �f. SENJU Model RC-RESLF37 LowFlow K3.7 Residential Concealed Pendent 888261 I • �. _ Liv ng/ 1 0 - - - 22 K=3.7,162F°,7/16"Orifice, Maximum Spacing 14'x14' - - I , I�"�-��� , ,23 /" ��� "� \, � � �j C Sprinkler head demand: 10 � SL / I V �� \ OFFICE COPY RC-RESLF-14 P gpm@7.3 -- -- ---L--y_._,_,.. ,k4 -, �/ - \ � I �, �I 4 , 1I,, �'; � 2� ,t. . 12. .s.," M. B it �'I�Ir - II�.� I -h r Linen—, �. �.32 C- ESLF-14 EY'IJ. -, .0P,� ,.. ��_, L- SRC �S IF�' iF ;'// T.34' : ,I iT33 /� M 36 �; L rI -' 8 l - 1K � F �� \ ATTENTION:THE DESIGN FLOW EXCEEDS THE MAXIMUM RATED FLOW ALLOWED BY THE ;F:;,_r,:3:''.':ll\''':',:.,- r y R RE LF I =I ,, IR st-I \ l \ .3 -, X1.37 i a wot8 J ''.---„:"/,'-:.-]:;.-.:\ - I H1 N ) H1© 1 � METER MANUFACTURER.THE PRESSURE LOSS TABLE FROM NFPA 13D 2013 EDITION 10.4.3(a) r1 rap ;� \, iHAS BEEN USED TO DETERMINE THE PRESSURE LOSS FOR THE DESIGN FLOW USED.A FULL F oIJJJ . �u r ° " > ``r ,, - _ / z\I _ - I•/ _' y,;;' - a w e \ a Bat .L FLOW TEST CONSISTING OF THE TWO MOST HYDRAULICALLY DEMANDING SPRINKLERS PLUS o o m AN ADDITIONAL FLOW OF 5 GPM FROM DOMESTIC FIXTURES SHALL BE PERFORMED TO v , _-�ilyrt Bath I / lig I� VERIFY SYSTEM PERFORMANCE ` 24 ,, I� 3�_�' 4(e..-4L-L.,' I > '42 I, m o F14 T4 C 1S F14 n w z� EXTERIOR WALL 72 ELEV=108' , ESLF 14 �` S � � �F try ly: �r III i u u I x`;41 STATIC: 60psi \ /i ' .r - II �ual RC-RESL z.-Y..j i Y �' M a a a 'z 3 RESIDUAL: SSgpsi q - r. / \ -- - RC-RE it " -_- _- ---- _.,, gce fz'owvuioFLOW RATE: 3650 pm - �� p' \ edn om 3 N B B a a m ze 1-1/4"A uaPEX � � T.45TO SYSTEM f '' �iT %kRGRESL 14 T. 7 � ii� X��� � r�'F 14 g z 'g 1 oO TO HOT WATER HEATER Ch Rm. QJyy}`/� ' (y G TrAffam. w o ELEV-104 \ .,�_ .. - < �/o li � ��SV IT{FM,il /'/ �II1. f ,- -%, ' 22 ��—_..% _ � NGPwdr _ cc Tr . 1 s� 7,�BALL"FULL PORT �. 2 p.�I�e,: w. ",� ® H.21 v zSAF=14 ■ - t }�I� 1 RC RES =14;2-612-2 4 z LL m a o te' ,KC-R4tgEr�4r 0 <wz� 7 i 1F _ - � I � # � d o I R 7 �III 1-1 9 E o ro / ELEV=100' ELEV=IDD' / ///,/„///l 3 THIRD FLOOR -„ ;._2............. SECOND FLOOR 1 ' , °C CO F F a Q _ 5/8METER35' -_ FIRST FLOOR R OF 80'OF F100:� = , „ F100 „ = , „ F100/ SHEET DESCRIPTION 1”COPPER-K 1-1/4"AquaPEX 1/4" 11-0" 1/4 1 _O1/4 = 1'-0" ALL LEVELS — WATER SERVICE DETAIL 6 D 5 15 SHEET NUMBER F1oo NTS i 1/4"=1'-0" © UPONOR - CONFIDENTIAL N Markup Legend SPRINKLER SYMBOL DEFINITION } t COLOR/LINETYPE LEGEND `" \ ✓� 0 XXX-XX BLUE LINES FEED TO FIXTURES(BATH,SHOWER,ETC.). DAddeL nine ' ° EK LIES— INTERLEVEL CONNECTIONS/SUPPLY.D o GRE BLAC NES SPRINKLER HEAD TO SPRINKLER HEA MAXIMUM SPACING(TYP) ' {.. j__ a O Line SPRINKLER MODEL(TYP) _ i �r = 1/2 PIPE SIZE >C°- HEAD SYMBOL(TYP) / - a J / �,� C " S /----/-;7' �� 3/4"PIPE SIZE a E Add Tee / / a �� �I� = 1"PIPE SIZE amiLT,�co, './ i £� _ Add Elbow _ ,/ If 7/= Il7/� fU7-6 1 L/jP = , //: _1-1/4"PIPE SIZE V >,>,', / � / a.� W , W W LSc,J On y�zp Add Coupling / / J//' m s, w 3 Add Head A 1 2 ..:. ,!..43 a w J -� / ' :ItHH: ��- ��- �) - //ll�l �cu.<000y 5u Note:All revisions must be reviewed by Uponor i , �- I ".,o o z¢ _ o - F ' . z oTable F002-1 I 17 ,1 zzz�yo�yzo3ia,.. ,i Icoo> o� zMultipurpose Fire Safety Systems I ', -_ oThe Uponor Residential Fire Safety System is a residential fire protectionsoz z¢ft < `e�o-oozzz f-usysteminstalled in combination with the cold side of the domestic potable ❑z ¢ �, m�'zwater system. Only licensed contractors trained by Uponor can install thisWmom¢oa > _=stem. -4 KEY PLAN � �� �0� �°3vCr 7. What to do if Changes are Required J zu ¢ o$ziyy ¢adIfanyfeaturesorobstructions require the addition or deletion of sprinkier F1 O1 ¢ `' _>° ¢ >¢NTS �<a�o�� zheads,orsignificant relocation of sprinkler heads,contact the Uponor Design pm acx< , -Department to determine if observed changes require a redesign(888.594.7726). 1,"AquaPEX TO SYSTEM _ oo2d o �,woz:u.„ JZF6S 5.1MAINSHUTOFF w '-z '-:oVALVELOCATION _zY, '.z ouo��¢w¢ u __ l ,,,, _ _-_ CONNECTIONSFROMFIRST , a = ¢1'AQUAPEX INTERLEVEL EC 7 { ,, ' QUAPEX INTERLEVEL z= <<- :!-, ozCONNECTIONS FROM SECOND ( �j {�� .' ,1 1 .� r .-� `I I - 7O FLOORTOSECONDFLOOR 1\� f _ ��,.zoooft5 y i /�/ FLOOR TO THIRD FLOOR \ / / \ I / s �” \\ I ;� H.2` r // \ Garage 1 i` D g N b i2 612 , -� FPITCH PA,TCI-T 7 I I_ 3 0 4 � � � , >>vocoi � �q- �� / ESLF 14 r� l � � H.4� � ---i RESLF-14 �/ ��4 RC� , �. / �-,, // .� � � � �ti -� ti �' • RES� 14 H.3 // RSL, I J / ester Bedroo �.// \T A ,4-:_ `�A / A �N ) f ;_, } ing r 11--/--HH-1- \� 7I L4 : , I / 1 a i "T.2 �,� j1,, l 1I 1 A \\ �. '��,. T.2 �ESLF 14 ( / z � / - . ,4 R �. 25 1 6 F4 05/ �_ / T sky^\ T.N FI H. a . i . _ ., , 11111 1 HI / M Bath'' 1- - r I. , I 1 H ^'I - Rb T.32 j1� ,; -, �� A / i RC-R LF-14 _ �� ?I le_ T 3 RES F 1 I ;9 -'ti �__-'4 ` - - - �;I�i �� ��� 13 I'F12-11"1-11';',11,1,11'1 � if.3� r F 4-',111.4-.-�� .TF 4 // RESLF 1` F.3 1CItC -!a i ��x x1 M u \ -moi— ` 3 ath m SI I,' ' at�h ,/ ;_ " it : •�,►39 -.1-1,,,;,:,;.,,,,,, o\II % t C1BE LF 1� ,, r �.�.� T8 �t t/ A‘r RC-RE L (� t Ft '1 T,43 \RC-RE LE-34' _' _ oJTATE .,2l e . .r' g 'fI(. 4.- y'-� 1 it - .� ��- °, ,_�- + if ntry,',.-,:,_- ii, aaz�o� s �� P R ESL D Ts, =r,/ - �a I Hz's , `Tr \ , (Bedroom \< �C SLF14i zN o0oa° ^o i 'il P ,. pa� L.L m � I /` �` SLF 14� / �11 T ® �� I� w RC -14 �� -- T.47 I I I A W N .19 Tech R di "�i Din.�TF.$ k ! h. cce V �\ _ ®iF�_14Pwdr.j I Vi O o "'. i0 lI_, �o � ` I Ce owe 48 ♦ T.5 ') H.21 © " y RC tdES1 SLF 14Lij„,,',2,,) z >`i,',' o r1 ¢ . p r------- ,_';',,=.c':,,..,4,-- , ER'�i- L��f N11#; w��,.`',.L,,.; Q w in.. R is � �w �� Y , ; � J o °o= o Porch us o g w E o 0 3 THIRD FLOOR—MIRROR 2 SECOND FLOOR—MIRROR FIRST FLOOR—MIRROR SHEET DESCRIPTION ALL LEVELS-MIRROR F1O1 1/^n = 1f_On F101 1/411 = 1i_On F101 1/4” = 1i_O" `tSHEET NUMBER = o 5 15 1/4"=1'-D" © UPONOR - CONFIDENTIAL F101 • , s Senju RC-RES:Open Web Truss/TJI Construction Insulation Recommendations AquaSAFETM GENERAL NOTES: spaces See General Notes 8.2.5.7 for Architectural In areas subject to freezing,care should be taken in unheated attic `+ ProPEX LF Brass Fire to cover Uponor AquaPEX tubing completely with insulation. Insulation Feature Requirements vi Sprinkler Adapter Teeshould follow the guidelines of the insulation manufacturer. See Uponor ` z 1. THIS SYSTEM IS DESIGNED AS PER NFPA 13D 2016 EDITION AS A RESIDENTIAL MULTIPURPOSE SYSTEM Fire Sprinkler Adapter Document"U"Uponor AquaSAFE Attic Insulation Guidlines"for attic 2 p Blocking Maybe p q SECTION 3.3.11.3. Required.If - Posh-on Nut installation guidelines(Provided in Contractors Documents package or online \ / O 'w u Blocking is Used, 1 1 at www.Uponorpro.com). -, O 2. UPONOR COMPANY RESERVES THE EXCLUSIVE•RIGHTS TO ALL DETAILS AND DRAWINGS AS SHOWN ON ..�-� 1/4"Min. I I a z Use The 2 Top w^ UNIS SHEET. THESE AYDETAILS AND DRAWINGS S ECU IOP TO THEY UINFORMATIONEXTENT LAW. COMPANY AND em v Max. 1 O Screw Holes. Planter Box Window,Ba Window or Similar Feature. UNAUTHORIZED USE MAY BE SUBJECT TO PROSECUTION TO THE FULL EXTENT OF THE LAW. �^ Bottom of ne of Extreme Temperature Installations y G o _racket to Face of Truss If no additinal floor area is created No Additional Sprinkler is Required. ^' u AquaSAFE Residential Fire Safety systems are often installed in attics or a w a 3. THE DESIGN OF THIS SYSTEM IS DICTATED BY SPECIFIC CEILING HEIGHTS AND ROOM SIZES. IT IS THE Fire Sprinkler Adapter~` - - other areas exposed to temperature extremes of heat and/or cold. Follow 8'-0"or less17',[i',u RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO ENSURE THAT THE CONDITIONS SHOWN ON THESE Mounting Bracket O the recommended extreme weather installation instructions to isolate and / > PLANS ARE EXACTLY AS THEY EXIST IN THE FIELD. DEVIATIONS FROM THE DESIGN MAY CAUSE THE l �J • protect system components from extreme temperatures. Because this RC-RES-161 W 3 LL w • SYSTEM TO BE UNABLE TO CONTROL A FIRE.IF THE BUILDING CONSTRUCTION DIFFERS FROM THE FIRE 0. u v n Oz system also delivers domestic cold water directly to plumbing fixtures, ® N\ o SPRINKLER PLAN,CONTACT THE SYSTEM DESIGNER IMMEDIATELY. 3-410 x 1 1/2" 9'-0"or less j,°��'ry z o_ } Uponor highly recommends that you protect the tubing with adequate / w u S Full Course I I - w u' insulation in warm weather areas to minimize heating of the cold water o m 5 v w 0 4. THIS SYSTEM AND THE ACCOMPANYING HYDRAULIC CALCULATIONS ARE DESIGNED IN COMPLIANCE WITH Thread SSS.rews \ 1.1 \ / Z a NFPA 13D 2016 EDITION. In Bottod Holes supply. •,`,,' o M7,0°:,i23 5. "STAND-ALONE"OR"MULTIPURPOSE,WET PIPE"SYSTEMS ARE NOT PERMITTED TO USE ANTIFREEZE. \ \ Installation methods include,but are not limited to: W rn m a W _ • Tenting over the fire sprinkler piping. I o\ I �\ O v+I-a S Lead-Free Fla[ 6. MODIFICATIONS ARE PROHIBITED.SPRINKLERS THAT HAVE BEEN PAINTED,CAULKED,MODIFIED OR -\ -rn i 9 • Additional layers of batt insulation. If additional floor area is created.Cannot exceed 18 f[z,be more than 2'-0" Concealed Senju DAMAGED MUST BE REPLACED. Concealed Flat • Increased depth of blown-in insulation. deep,more than 9'-0"wide and be with in the coverage area of the < ''m w Sprinkler Head Cover Plate sprinkler.No Additional Sprinkler is Required. z w u w' o ,>_- _.]=F, 7. WATER SHUT OFF VALVE IS NOT PERMITTED THAT ISOLATES THE SPRINKLER SYSTEM. Caution: If you will be installing spray foam insulation,make sure to -2.!. F<m o z-o r Protect all components during application.Consult with the spray foam ¢ c c-'o o 3 8. OWNERS MANUAL MUST BE PROVIDED TO THE OWNER. Senju RC-RES:Traditional Wood Framing Construction p p g pp pry u.u N o❑F w s z u, manufacturer to ensure compatibility with all products before application. NFPA 13D Table 7.5.5.3 Distances From _- >z o z¢^z Q Heat Sources -'701-'7,z;,=.-ftft 9. THE MAIN SHUT OFFS OA TAG ORIE A SIGN STATING SHEAT REQUIRE IS REQUIRED;"WARNING,THE u w o o F Consultation with local building officials is encouraged to ensure compliance �.s w w z x�o WATER SYSTEM FOR THIS HOME SUPPLIES FIRE SPRINKLERS THAT REQUIRE CERTAIN FLOWS AND C � <='y PRESSURES TO FIGHT A FIRE.DEVICES THAT RESTRICT THE FLOW OR DECREASE THE PRESSURE OR ProPEX LF`Brass Fire with local building codes. o 33 x,o j u=0 3¢u AUTOMATICALLY SHUT OFF THE WATER TO THE FIRE SPRINKLER SYSTEM,SUCH AS WATER SOFTENERS, Sprinkler Adapter Tee Fire Sprinkler Adapter Ordinary Intermediate _,.,z`c 5 0-- -F,,N a P P Heat Source Temp. Temp. re c >oo c- F= FILTRATION SYSTEMS AND AUTOMATIC SHUT OFF VALVES,SHALL NOT BE ADDED TO THIS SYSTEM a Push-on Nut 135°-170° 175°-225° o p >'- "`- z. • WITHOUT REVIEW OF THE FIRE SPRINKLER SYSTEM BY A FIRE PROTECTION SPECIALIST.DO NOT REMOVE o z u ft ft m<<o Bending PEX Tubing o- <�_F THIS SIGN". II'Ir r' Side of Fireplace 36" 12" c-S z w 114.Min. The minimum bend radius of Uponor PEX tubing in any direction is six times Front of Fireplace 60" 36" w''w ¢ 5< z 3 F 1%2 Max. the outside diameter 6 x OD). m°m"">n z o 10. ALL INTERIOR PIPING TO BE UPONOR"AquaPEX"UNLESS NOTED. z ( ❑-u y w n Fire Sprinkler Adapter Bottom cf nounting Bend supports are available for 3/8",1/2 3/4"and 1"Uponor AquaPEX Wood Burning Stove 42" 12" H.:4:o¢z=z ¢9=s 11. UPONOR"AquaPEX"TUBING TO BE SUPPORTED PER NFPA 13D AND MANUFACTURER'S RECOMMENDATIONS. Mounting Bracket Bracket to=ace of Truss tubing to facilitate 90-degree rigid bends. Kitchen Range 18" 9" Q 553 o o u 55.J 5 z y, �� Wall Oven 18" 9" u ftzftsff�wyfXo-Q 12. MINIMUM SPACING BETWEEN SPRINKLERS IS 8'-0" REFER TO SPACING CHARTS FOR MAXIMUM SPACING 2-410 x 1 1/2" Recommended Tubing Length Between Fittings Hot Air Flues 18" 9" x N uF os u BETWEEN SPRINKLERS AND FROM WALLS.SPRINKLER HEAD MANUFACTURERS MAY HAVE MORE Full Course w<Oao=<u z<r = ouy ; RESTRICTIVE SPACING LIMITATIONS. Thread Scrows i I Fitting Size Minimum Tubing Length Uninsulated Heat Ducts 18" CwoF z In Top Holes r -r ff 3/8"ProPEX Fitting 2Uninsulated Hot Water Pipes 12" wT~_ o2o F m ❑ Fwp0> o 13. SPRINKLERS ARE NOT NECESSARILY CENTERED IN ROOMS DUE TO LIGHT FIXTURES OR OTHER CEILING _ / Side of Hot Air Diffuser 24" 12" z'n ft y a N o_ `z MOUNTED OBSTRUCTIONS. 1/2"ProPEX Fitting 2 1/2" \ Front of Hot Air Diffuser 36" 18" 3,u x ¢ > <w< 14. THE PLUMBING TIE IN CONNECTIONS ARE SCHEMATIC IN NATURE AND CAN BE INSTALLED OFF THE _ 3/4"ProPEX Fitting 3 1/2" Hot Water Heater - 6" 3" ¢u F N Lead-Free Fla[ -' =o o z „o j y o SPRINKLER LOOP ANYWHERE BETWEEN SPRINKLER TO SPRINKLER CONNECTION. Concealed Senju \ ` 'r" '.' ' :1_,,--________ 1"ProPEX Fitting 4 1/2" Furnace 6" 3" 0‘-,..0,2`. ,f 3 J>z n Concealed Flat No;Uo_5z__J Sprinkler Head Cover Plate 1 1/4"Pro PEX Fitting 5 1/2" SOW-250W Light Fixture 6" 3" - n 3 n o o m 15. THIS SUGGESTED LAYOUT IS BASED UPON INFORMATION PROVIDED BY OTHERS. CHANGES IN a n<��w�,u. CONSTRUCTION OR FIELD CONDITIONS MAY OCCUR WHICH MAY REQUIRE CHANGES TO THE LAYOUT. IT I5 250W-499W Light Fixture 12" 6" n u ¢, 3 y n.y z y o oLctl THE RESPONSIBILITY OF THE INSTALLER TO NOTIFY UPONOR TECHNICAL SERVICES OF SUCH CHANGES. z_ M � Exposed installation Requirements. w 16. NFPA 13DOBSTRUCTIONS TO RESIDENTIAL SPRINKLERS • 8.2.5.6* SHADOW AREAS SHALL BE PERMITTED IN THE PROTECTION AREA OF A SPRINKLER AS LONG AS Uponor AquaPEXr"'tubing(white)and ProPEXTM EP Fittings and ProPEXr"' I m THE CUMULATIVE DRY AREAS DO NOT EXCEED 15 FT'PER SPRINKLER. Brass Fittings are approved for exposed installation where the following • 8.2.5.7 SMALL AREAS CREATED BY ARCHITECTURAL FEATURES,SUCH AS PLANTER BOX WINDOWS,BAY conditions are met.(UL 1821 Approved) WINDOWS,AND SIMILAR FEATURES,SHALL BE EVALUATED AS FOLLOWS: /� (1)WHERE NO ADDITIONAL FLOOR AREA IS CREATED BY THE ARCHITECTURAL FEATURE,NO Exposed Wood Joist Ceiling Assemblies. o2 2 /// a Um ADDITIONAL SPRINKLER PROTECTION IS REQUIRED. 1. Joists are of dimensional lumber,engineered wood,wood I-joist or open ^' U m (2)WHERE ADDITIONAL FLOOR AREA IS CREATED BY AN ARCHITECTURAL FEATURE,NO ADDITIONAL web wood joists. m SPRINKLER PROTECTION IS REQUIRED,PROVIDED ALL OF THE FOLLOWING CONDITIONS ARE MET; 2. Joist are of depths from 6-16 inches(152-204 mm). (a)THE FLOOR AREA SHALL NOT EXCEED 18 Fri(1.7 M0) 3. Joist are of spacing from 12-24 inches(305-610 mm)on center. o❑ (b)THE FLOOR AREA SHALL NOT BE GREATER THAN 2 FT IN DEPTH AT THE DEEPEST POINT OF 4. Joists can be exposed after installation. \ \ THE ARCHITECTURAL FEATURE TO THE PLANE OF THE PRIMARY WALL WHERE MEASURED 5. Metal pipe hangers spaced at maximum 24 inches(610 mm)on center 1.55" I"- / 1.66" ALONG THE FINISHED FLOOR. are used. � (c)THE FLOOR SHALL NOT BE GREATER THAN 9FT IN LENGTH WHERE MEASURED ALONG THE 6. Listed residential automatic sprinklers of maximum activation Z" -4" Hanger 1" Hanger PLANE OF THE PRIMARY WALL. temperature rating of 155°F(68°C). (d)MEASURED FROM THE DEEPEST POINT OF THE ARCHITECTURAL FEATURE TO THE SPRINKLER Tubing Support Spacing: SHALL NOT EXCEED THE MAXIMUM LISTED SPACING OF THE SPRINKLER. Metal Tubing Support. (3)THE HYDRAULIC DESIGN SHALL NOT BE REQUIRED TO CONSIDER THE AREA CREATED BY THE 1. Metal tubing supports designed for plastic tubing shall be used. (Anchor AquaPEX Tubing Securely Enough to Support the Tubing,Yet Relaxed ARCHITECTURAL FEATURE. 9 Enough to Allow the Tubing to Expand and Contract) 2. Do not use supports that will damage the tubing.Inspect metal 17. NFPA 13D 8.3 LOCATION OF SPRINKLERS. supports for sharp edges. 1. Along Horizontal Runs,Install Supports Every 32",if Horizontal Runs are • 8.3.1 SPRINKLERS SHALL BE INSTALLED IN ALL AREAS EXCEPT WHERE OMISSION IS PERMITTED BY 8.3.2 3. Do not rigidly anchor Uponor AquaPEX"'tubing with supports.Allow Continuously Supported,Place Tubing Supports at Six-Foot Intervals. enough tubing for freedom of movement to expand and contract. THROUGH 8.3.8. 2. Along Vertical Runs,Install Supports Every Four to Five Feet,at Each • 8.3.2 SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55 EI-2(5.1 M')AND LESS Floor and at a Mid-story Guide. z • 8.3.3 SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS,LINEN CLOSETS,AND PANTRIES THAT `m a MEET ALL OF THE FOLLOWING CONDITIONS: In-line Flow Test f z (1)THE AREA OF THE SPACE DOES NOT EXCEED 24 FT'(2.2 M2). The In-line Flow Test can be constructed on site. It performs a flow test to 5 5 5 (2)THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE Standard Riser Assembly ensure proper system operation and flow(see Figure FO01-8). 0 iO ''''-1.' MATERIALS AS DEFINED IN NFPA 220,STANDARD ON TYPES OF BUILDING CONSTRUCTION. In a multi-purpose system a single control valve controls both domestic and z H P • 8.3.4* SPRINKLERS SHALL NOT BE REQUIRED IN GARAGES,OPEN ATTACHED PORCHES,CARPORTS,AND fire safety needs. <m 0' 0' 1 z SIMILAR STRUCTURES J O o m ry • 8.3.5 SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS WITH OR WITHOUT STORAGE,PENTHOUSE / Uponor AquaPEX a z ft F 5 ft w EQUIPMENT ROOMS,ELEVATOR MACHINE ROOMS,CONCEALED SPACES DEDICATED EXCLUSIVELY TO AND Tubing f z CONTAINING ONLY DWELLING UNIT VENTILATION EQUIPMENT,FLOOR/CEILING SPACES,ELEVATOR SHAFTS, j j W "' O PURPOSES.CRAWL CES,AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING z 2 z H • 8.3.5.1 SUCH SPACES THAT CONTAIN FUEL-FIRED EQUIPMENT SHALL ALSO COMPLY WITH 8.3.5.1.1 OR U 1 .. 0 O a O a s w 8.3.5.1.2. } w zuCizavui n¢ • 8.3.5.1.1 WHERE THE FUEL-FIRED EQUIPMENT IS ABOVE ALL OF THE OCCUPIED AREAS OF THE DWELLING I -------- j _ n a F w U w Q / aF- czft UNIT,NO SPRINKLER PROTECTION SHALL BE REQUIRED IN THE CONCEALED SPACE. 8 8 az o 5 in o • 8.3.5.1.2 WHERE FUEL-FIRED EQUIPMENT IS BELOW OR ON THE SAME LEVEL AS OCCUPIED AREAS OF THE rY 1__1 N u a a z p DWELLING UNIT,AT LEAST ONE QUICKRESPONSE INTERMEDIATE TEMPERATURE SPRINKLER SHALL BE Male Threaded Coupling ProPEX Fire O �, Sprinkler Adapter Z N in INSTALLED ABOVE THE EQUIPMENT OR AT THE WALL SEPARATING THE SPACE WITH THE FUEL-FIRED w o EQUIPMENT FROM THE OCCUPIED SPACE. �" 11.... o Q Male Threaded Coupling - 1"Ball Valve Cce Lu • 8.3.6 SPRINKLERS SHALL NOT BE REQUIRED IN COVERED,UNHEATED PROJECTIONS OF THE BUILDING AT -To Hot Water Heater P In LLJ o ENTRANCES/EXITS AS LONG AS THE DWELLING UNIT HAS ANOTHER MEANS OF EGRESS. . w 0 • 8.3.7 SPRINKLERS SHALL NOT BE REQUIRED FOR CEILING POCKETS THAT MEET THE FOLLOWING / Female Threaded ce Tee with Water N I..L F Lt z CONDITIONS: - E Ig 'c'Gauge 8 (1)THE TOTAL VOLUME OF ALL UNPROTECTED CEILING POCKETS IN A COMPARTMENT DOES NOT EXCEED Sprinkler Orifice - O 0 0 -a o C1 100 FTa(2.83 Ma). ,° II [I (Optional) /'� z p (2)THE ENTIRE FLOOR UNDER THE UNPROTECTED CEILING POCKET IS PROTECTED BY THE SPRINKLERS = _ ce z - u m¢ ry d AT THE LOWER CEILING ELEVATION. E - Uponor Warning Signs (3)*THE INTERIOR FINISH OF THE UNPROTECTED CEILING POCKET EXCLUDING DECORATIVE Flow Test 1 1 1 I-1 f z 5 o TREATMENTS IS NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE MATERIAL. To ensure the system provides enough water for proper fire sprinkler ■r r Q °..'co f rn iO performance,you should conduct a Flow verification test. ,o (4)SKYLIGHTS NOT EXCEEDING 32 FT'(2.97 M2)SHALL BE PERMITTED TO HAVE A PLASTIC COVER. v J m -. • 8.3.8 SPRINKLERS SHALL NOT BE REQUIRED IN CLOSETS IN GARAGES AND EXTERIOR CLOSETS o Note: The NFPA 13D Installation Standard does not require flow j. f m f£ a^ (REGARDLESS OF SIZE)LOCATED ON EXTERIOR BALCONIES,EXTERIOR BREEZEWAYS/CORRIDORS,OR - m verification. 11 v E m o=ft" f ACCESSED FROM OUTDOORS WHERE THE CLOSET DOES NOT HAVE DOORS OR UNPROTECTED '-' I� y P G s 00 a Main Fire Sprinkler G 3 u LLS PENETRATIONS DIRECTLY INTO THE DWELLING UNIT. _ Before performing a flow verification test,confirm the water pressures by • 8.3.9 SPRINKLERS SHALL BE INSTALLED IN ANY CLOSET USED FOR HEATING AND/OR AIR-CONDITIONING z - Shut-off Valve f i,5 O, 5,-, contacting the Water and Sewer Department of your local city. Ensure the O u m EQUIPMENT,WASHERS AND/OR DRYERS,OR WATER HEATERS EXCEPT AS ALLOWED BY 8.3.8. available water pressure matches the pressure used in the system design. 18. INSULATION GUIDE LINES PER NFPA 13D. Note: The sprinkler plan indicates the most hydraulically remote sprinkler SHEET DESCRIPTION - • 9.1.1*WET PIPE SYSTEMS IN AREAS ABOVE 40°F. A WET PIPE SYSTEM SHALL BE PERMITTED TO BE TO BE 4, 0 (or pair of sprinklers). For test requirements on other sprinklers,consult GENERAL NOTES&DETAILS USED WHERE ALL PIPING IS INSTALLED IN AREAS MAINTAINED ABOVE 40°F,INCLUDING AREAS PROPERLY a your local code. INSULATED TO MAINTAIN 40°F. •• A.9.1.1 IN AREAS SUBJECT TO FREEZING,CARE SHOULD BE TAKEN IN UNHEATED ATTIC SPACES TO Note: It is a good idea to notify the fire inspector at least 24 hours prior to COVER SPRINKLER PIPING COMPLETELY WITH INSULATION. INSTALLATION SHOULD FOLLOW THE performing a flow verification test. This may speed up the inspection GUIDELINES OF THE INSULATION MANUFACTURER.FIGURE 8.9.1.1(8)THROUGH FIGURE A.9.1.1(F) process and eliminate the need to repeat the test for the inspector. SHEET NUMBER SHOW SEVERAL METHODS THAT CAN BE CONSIDERED. THESE ARE FOR ILLUSTRATIVE PURPOSES ONLY. CONSULTATION WITH THE GENERAL CONTRACTOR AND/OR OWNER IS RECOMMENDED TO ENSURE Note: See"AquaSAFE Flow Test Instruction Sheet"(Provided in PROPER METHODS AND MATERIALS ARE USED TO MAKE SURE 40°F WILL BE MAINTAINED. Contractors Documents package or online at www.Uponorpro.com)for more information on Flow Test Setup,Assembly,Performing the Test and Troubleshooting. If there are any questions please contact Uponor. © UPONOR - CONFIDENTIAL FO 0 1 FOR OFFICE USE ONLY–SITE ADDRESS: This form is recognized by most building departments in the Tri-County area for transmitting information. Please complete this form when submitting information for plan review responses and revisions. This form and the information it provides helps the review process and response to your project. IICity of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT w Transmittal Letter T I G A R n 13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.718.2439 • www.tigard-or.gov TO: City of Tigard DATE RECEIVED: DEPT: BUILDING DIVISION RECEIVED JAN 232017 FROM: Gavin Thomes CITY OF TIGARD COMPANY: Alliance Plumbing BUILDING DIVISION l PHONE: (503) 492-3490 By. RE: 13771 SW Silent Fox Terrace MST2016-00315 (Site Address) (Permit Number) West River Terrace - Lot 29 (Project name or subdivision name and lot number) ATTACHED ARE THE FOLLOWING ITEMS: Copies: Description: Copies: Description: Additional set(s) of plans. 2 Revisions: Fire Sprinkler Plans Cross section(s) and details. Wall bracing and/or lateral analysis. Floor/roof framing. Basement and retaining walls. Beam calculations. Engineer's calculations. Other(explain): REMARKS: Complete re-work of the multipurpose fire sprinkler design to adjust for lower than expected water pressure. FOR OFFICE USE ONLY Routed to Permit Technician: Date: -1-aotrr Initials: 64 Fees Due: ❑ Yes ❑ No Fee Description: Amount Due: '14.1,ei,� F r2 SPr�v��Z�. �lct�S $ iE s 03 $ $ $ Special Instructions: Reprint Permit(per PE): ❑ Yes ,-Vo ❑ Done Applicant Notified: f&h i C-- _ Date: 6'2'ii4y 9-1?/i7 Initials: 4,r 1:\Building\Forms\TransmittalLetter-Revisions.doc 05/25/2012