Loading...
15055 SW SEQUOIA PARKWAY STE 140 1 ^, ?71ri STRUCTURE Awvt iii ---- CAULKING IN 1/2' SPACE D1/2' DAIT !NSUAN,�EL ------ WILDING INFORMATION ' 3-i/1 FsATT •NSUL. SUSPENDED CEILING r I -- — --- 3 5/8' MTL.STUDS • I6'O.C. _--- \� BUILDING OWNER: FaCIFIC REALTY ASSOCIATES, L.P. 0 _ 50 SIDYPE S GYP. BAD. - — - -------J� _s_,� ���,_ 15350 SW SEQUOIA PK.bVY #300 I'RO.�EC ! 3330 BOTH SIDES SCREW ATTACHED TO PORTLAND CARMAN RD. '---� — PORTLAND, 0 R E 97224 -- -- CENTER LINE OF STUD EXIT#291 _ �__` 15 \� ` _`� — (503) 624-6300 (PHONE) -- o-- -o--� I 12 13 - (503) 624-7755 (FAX) I! I ao-------t—o--- � - - 1 �'""`° �►n `�_�� BLDG. #: PCC BLDG. 8 (PCC 232) 14 �NNNiI � G --- - 3-1/2' BATT I1J.SUL• Intl ASF BLDG. PERMIT ML4' RUBBER BASE-TYP. 11 17 ATTACH BOTTOM TRACK TO FLOOR WI1M r r uuwu� `etc rmnn. rourrmn POWrER DRIVEN ANCHORS AT 24' OC. ` C� c-��� �� "Uuu,� � r cul C �� C� CARPET AND "AD o,- v , j CONST. TYPE.. V—N FINIbH FLC-JR TOP OF SLAB rrL yrrm"n.im� s - m nmm�rmrtmmr ° � $ 7 TENANT INFORMA PION ONE HOUR WALL SECTION W/ INS. s - 2 SC'ALl l it ._ 1'-0" �, ' _ 4 m� 3 a C,, rt A T ENANT: GEOFNGINCERS x o / ( -1/2' 24 GA METAL STUDS AT I0'-0' O.C. �` , i•.�••r Q rCM- BLDG. STRUCTURE ABOVE FOR wu B 44 WALLS E � TVAN 12'-0' N k5ECTIhCj WALLS VENLIWITHOUT INTJ FLOOR ARCS',. 1 1 , 1 37 SF TOTAL CD 14") \ LOCATION PLAN 10,272 SF OFFICE � NO SC'f�L E BLOCKING TYP. � FASTENING POINTS EXISTING SUSPENDED CEILING _—RAW T5-415 RECF55ED REVEAL HEADER I GENERAL NOTt✓S — 3-5/8'MTL.STUDS * 24' O.C. 5/8'GYP. BIRD.BOTH SIDES 3 -----CENTER LINE OF STUD 1. ALL, CONSTRUCTION WORK SI [ALL BE DONE IN COMPLIANCE: WITH THE LATEST EDITION OF THE UNIFORM BUILDING CODE. AS EL AMENDED BY THE STATE OF OREGON AND ALL OTHER STATE OR �I LOCAL CODE REQ1.11REMENTS THAT APPLY. --T----- 4' RUBBER BASE-T'P" 3 THE CON'T'RALTO[: SHALL VERIFY ALL DIM[:NSIONS .AND CONDITIONS /----ATTACH BOTTOM TRACK TO FLOOR WITH Q POWDER DRIVEN ANCHORS AT 24' O.C. SHOWN ON DRAWINGS AND A'f TME EXISTING BUILDING AND NOTIFY FINISH FLOOR ARCHITECT OF ANY DISCREPi,NCI ES PRIOR TO STARTING THF WORK. TYPICAL WALL SECTION 3. CONTRACTOR SHALL KEEP THE AREA OF WORK FREE OF GARBAGE SCALE I'' = 1'-0" AND DEBRIS ON A DAILY BASIS INCLUDING DOCK ACCESS AREAS. 4. CONTRACTOR SI TALL KEF•.P THE ROOF FREE OF DEBRIS (I.E. NAILS, TO/BLGCs�STR-UCTU,E A15OAE ©R O.C. SCREWS) AT ALL TINIES. WALLS LONGER TP4N 12'-0' WITHOUT INTER51ECTIN'G WALLS 5. ALL GYPSUM BOARD TO BE A MININIUM OF 5/8' THICK VERTICALLY R-11 BATT IN5ULATION 4' CENTERED OVER WALL ATTACHED 'f0 3 1/2" METAL S'T'UDS 24" O.C. WITH 1" TYPE S-12 - BLOCKING TYP. 9 FASTENING POINTS SCREWS 12" O.C. UNLESS OTHERWISE NOTED. F X'15TING SUSPENDED CEILING ��- RACO TP5-4B RECESSED 6. IN FINISHED SPACES FURR-OUT BUILDING COLUMS AND EXTERIOR REVEAL HEADER WALLS WITI-T 5/8" GYPSUM BOARD OVER METAL STUDS. 3-1/2' BATT iNSUL. 7. ACOUSTICAL CEILING SYSTFAIS: SUSPENSION SYSTEM TO BE EXPOSED _ ME:TAT, 'T-BARI., REFIN1SLi:'.D COMPLY WITH U. S. O.WHITE, TO � — 5/8/GYP. BRD BOTH L. STUDS 0 5IDE5 STANDARDS. ,NSTAL,L LATEIRAI , BRACING PER CODE. CENTER LINE: OF STUD w;7 ;st >p'- 8. 8. ALL DOORS SHALL BE 3'-U"x7'-0"xl 3/4" SOLID CORE WOOD (_1NLESS -- NOTED O'fHERWISE. DOOR- HARDWARE SHALL BE SCHLAGE AL EW-� --- ~ �1 SERIES. BUTTS, CLOSERS, AND OTHER HARDWARE TO MA"fCT-T -- 3-I/z' BATT INS:tL. IN SOUND A`.rTEN'.IATION WALLS BUILDINGS►ANDARD. DOORS WITFI CLOSER USE D-•SERIES "�'� O CLV -- -4' RUBBER BASE-i 'o p W - C/) ---ATTACH BOTTOM TRACK TO FLOOR WITH d � Q POWDER DRIVEN ANCHORS AT 24' oma. 9. HVAC TO BE A BALANCED, DESIGN-BUILD SYSTEM. MECHANICAL w U 3 FINISH FLOOR CONSTRUCTION LEGEND CONTRACTOR TO SUBMIT ZONE. MAP AND THERMOSTAT LOCATIONS2-1 U 4118' FOR TENANT/LANDLORD APPROVAL BEFORE CONSTRUCTION. U a 04 r � EXIST!145 TO REMAIN � WALL SECTION W/ SOUND INSUL. kxISTING TO BE REMOVED 10 PP.OVIDE SPRINKLER,; BELOW SUSPENDED CEILING PER CODE. scALt; 1�'- 1'-0" . , , � , � � I REVISION S[ ,.INKLER HEADS SHALL BE CENTERED IN 2 X 2 CEILING TILE. 0-T-C ��� NEW STANDARD WALL LAYOUT OF SPRINKLERS BY CONTRACTOR. — 5/8' PLYWOOD DECK OVER AREA occupancy Type �L-S z l. INDICATED ON PLAN rxx=xxxK= NEW 5TANDAR17..) WALL WITH INSULATION Occupancy toad L�? / JOISTS a TU 11. PROVIDE LABEL FOR EACH CIRCUIT AT PANEL FOR IDENTIFICATION Construction Type 1�L — LOCATE DI(i�GTLY OVER S1UD5 � NEW OFFICE;WARE'�OU3E SEPERATION WALL Anted Cu-riUor A 3. ( — — b'FG.INSULATIGN PURPOSES. THERMOSTAT LOCATIONS TO BE REVIEWED BY OWNER �- ;� ,-IR�'EFGID.EIND�GEIING Energy Code nJ4 1LATlON ff DOUPLEX RECEPTICAL PRIORTO INSTALLATION. Accessibility 4017PA Je 45 . T'ICAL 5/8'GYP.BAD - ----3-5/b'25 GA MTL.STUDS e IV O.C. FOURPLEX RECEP - 5/8 GYP.BRD 12. TELECOMMUNICATION SYSTEM BY FUTURE TENANT. TEL/DATA PULL ---------CENTER LINE Lf6TUD FEXISTING FIXTURE TO REMAIN 13. PROVIDE ACOUSTIC GASKETS WHERE WALL CNTI?RSECTS MULLIONS DEFEItRF Ffprinklat OR GLAZING. Fir?s Ftre Marra i -- _\x`' 2 X 4 FLUOR. FIXTURE W.i PARABOLIC LENSE Mcchonfcall 2 X 4 FLUOR. FIXTURE W/STEADY BURN BALLIST 14. CONTRACTOR TO PROVIDE BUILDING STANDARD BLINDS AT ALL Plumbing 5/8 r'�PElU2G"P.BRn EX'TIF IOR GLASS. 1Etcctric Trotsti/15/U 3 SUPPLY DUCT Shop I)raveings - ___ 3-112,FG.INSULATION 15. CONTRACTOR TO PROVIDE: AND INSTALL FIRE EXTINGUISHERS AS aha► RETURN DUCT 6' BASE 1--- ,-- 4'RUBBER BAS-TYP REQU1 RED PER CODE. Sequoia Pkwv Suite140. 15055 SEE FINI5HE I - RNLR CHANNEL SPRINKLER SUP2003-00502 FOR MATERIAL ATTACHED TO FLOOR 16. of 4 FIMATE A F� EXIT SIGN 16. ALL DIMENSIONS ARE TO FACE OFSHEETROCK UNLESS OTHERWISE FINISH FLOOR TOP OF SLAC? NOTED. CITY OF TIGARD RE-,^1ROOM 51GE OFFICE SIDE Approved....... ...- .... . ..__............... b<1 i� Conditionally Approved.......... ..........._._......For only the ( ►� RESTROOM WALL SECTION PERMIT NOw k o described SCALE' i" , f � z �j .. 'Y ..ttr'f X41.,. :.,.,.h. , , ..��, l' , .. �w 4,C<�::�: 1, .._-nl,.:....... .... _... .�t..n 'T_ �:.J.,._ .]:U r.x.tY.r.:' � ....... ,...,. ., .., .•.._... ... ,�....1"..,u,... n..... . �— .... �• f FINISH SCHEDULE _ JUIN i;. ! ,� U'ALL5 _ _ 1 RM# NAME FLR BASE NORTHJ EAST SOUTH WEST_- - CEILING CLC. HT, REMARKS I - II , I II , -� 21 - 'e -^ II - , n �I-_ II _^ I I n I ---- I II 1 -- - - 101 ENTRY/WAI1 /REC --- LP/WO RIF c U �-,GWB E FGWB E FGWB-- E PGWB E 5AT 9'a' -- - - - j • 1� 12 `� _ 2 5 2 5 " 2 � 102 CIRC LP RF -- - E PGWB E PGWB E PGWB E SAT 9'-0' - ___-__ _ 103 CONF. •-«- _CP - RF E P'aWB E PGWB9 _ E PGWB E PGWB E SAT '-01 - OF 104 CONF, CP F'F E WW F61115 E F16iU_B _ E PGWB E 111111 PGWB I E SAT 9'-0' - , -- - -I- - -- - - - - - -- /--- -- - -- - - --------- --------------_ ( -___- - --__-----_--- - --- ------___ PacTrust IIVAC 'Specification 1 2 2.5 3 � 46 2 1 fl.: �.. JOHN I I. 1`,3I�;�rt IIVAC - Design Procedure `; I u , i u , _ i `;� ii inventory existing 11.V.A.C. rooftop units and submit to owner a conditions report of each unit: ® �, 1 , _ 0 1 i - 0 u 1 2 1 - 0 1I 1 `) 1. List tonnage of each tufa. ­01111111-- �J - -- 215 6 _ 2. List b unit recommended maintenance or repair of unit. Use existing H.VA_.C. units to design mechanical H.V.A.C. system per Pac"frust design standards. PROJECT #03330 I - - _ IIVAC Design Standards I - a The following are minimus design standards for all PacTrust properties: 1. 350 square foot per ton. 2. No zone shall be larger than 1,000 square feet. [urge bullpen or common areas are the exception. iAl 3. Specialty rooms to be considered according to exterior load phis interior use criteria as provided to PacTrust by Tenant prior to construction. Pricing should reflect cost in ADDITION to the basic allotment oti 350 square feet per ton. Computer/Server andTelephone rooms to have provision for low ambient operation and ?4-hour use. 4. Units: Lennox, Trane, York and Carrier. o 5. Unit placement 24' minimum to center from roof edge. Multi-placed units should be symmetrically in a line based on structural x I calc►ilations by engineer. (Group Mackenzie) ?� 6. Curbs: 14" curbs. Assembled and leveled to roof, anchored to structural members below roofing. � ' N N "- -'.' N a. Professionally roofed in all curbs and penetrations by Pac"Crust selected roofer. LB __---- - - - I I I _ _ b. Unit trust be levet, sealed with no air leaks and counter flashed. - - c. Condensate must be trapped at unit. � �x o • O I , • , • _ O , 7. Seismically attach unit to curb in code;-, .proved fashion, x d - - - 8. Roof jacks for low voltage and gas- must be roofed in at the same time with unit curb. No cold patch. N N 1 Poof jacks shall be secured with sealant and stainless pipe clamp. Gas pipe on interior of building only. Do not isolate a future d, M M I I - • - - - - - I I'I space from gas service. " a 9. Low voltage in Sealtite conduit from below roonine direct to unit. Do not exceed bend radius manufacturer's guideline. 10. Economizer to meet code and as fol►ows. a. Barometric relief on 5 - 7 i/2 ton units. b. 8 tons and above must have power exhaust. c. 1 '/2 thru 4 ton OSA intake with damper. - - - -� 11. Smoke detector on R.A. 5 ton and above. Meet code requirements on larger units. Q 12. All t>nits to meet or exceed current energy efficient code requirements. \ gY Y I W ' _ I AN - -� N N I 13. Drop cans to full size of unit curb opening. Minitrnnn 26 gauge with supply air. Edges of supply air sealed. Drop cans to be a . O extended to within T of ceiling. C ---------- -- - -- - - - - - - - - - - - - - - _ - - 14. . -- - - -- - - - - r -- - - h st ihution Ductwork: • N ' ' a. Spiral only if exposed. b. 26 gauge or to SMACNA standards if pipe i5 concealed above drop or hard ceiling. a c. Wrap concealed with Minimtum R4.2 & FSK barrier. { d. Hangers 12 gauge v ire or 1 9-gauge 1" wide strap. Exposed duct must have all thread hangers and full diameter strap up to 18" O. Larger than 18" must have saddle type clamp. �;,� 3 �, '' N ,`; • _ I "� I e. Branch duct plumb ands uare no octo us). No 90°take off. No tees. 0-4 CEILING NC. _S } q ( p N I. REPLACE BALLA5T5 A1�lD RELAMP ALL f. Each branch duct to have balance damper in Y branch, a - I I I _ r I. I I EXI5TING LIGHT FIXi'URE5 WITH T S TUBES. 15. Flex duct well be no longer than C from rigid duct clown to diffuse.. (LIG4TING CONTRACTO TO SU3MT ALL 16. Diffusers - PacTrust standard Krueger perforated face or equivalent with adjustable vanes. Return perforated face with no metal FORMS TO PGE TRU ,T RINE) FOR REBATE shine showing thru grill. No transfer grills, each return air to be fully ducted to unit via return ductwork main. CEILING GR IN Ton; '1 _ _ _ _ , AND COPT" PACTRUST) I 17. T-Stat - Total-line 7 day programmable with lockout function - Auto changeover only. DlkfGRID 71 , 5 ON 6UILDING ' N 18. Exhaust Fans = GRIDS B, S F � I � , • - - ,p • I 2. ALL EXIT 51GNa TO BE fNEW LED REDa. Restroom/Conference Room FIXTURES. 1 1. Individual small restrooms - Broan 688 with zone level of 4 or less. Electrician to power from light switch. - 2. Larger restrooms and conference roosts will require use of roof mount Acme or approved exhaust an to meet code cfin. Fan must 3. MAKE ALL EXISTiN.� FIE ALARM 5 TSTEMS be installed on factor curb with E3DD and roofed in b roofe.• no cold patch). Run continuous or on time clock as required. OPERABLE: DETECTO S, PULL STATIONS 4 Y Y ( p ) q HORNS r� U II - - t - I I CABINET SPECI�� ICATIO W I I I 1. AWL CUSTOM GRADE STANDARDS FOR CASEWORK AiND C'OUNT'ER TOPS U.O.N. (DEFAULT TO IF NO OTHER STANDARD GIVEN. ) � 2. HIGTI PRESSURE LAMINA TE (P-LAM HPL) ALL EXTERIOR SURFACES, INCLUDING 4 TOE KICK. EDGE BANDING (MATC1-IING PVC �,...� • I ACCEPTABLE), FIN ENDS, DOORS, LIGH C VALENCE E CC. UPPER CABINET' BOTTOMS OPTIONAL HPL FINISH, STANDARD MELAMINE �' FiNiSH. OPEN CABINETS OPTIONAL HPL FINISH, STANDARD MELAMINE FINISH. `� u J N I-- I __� TOE KICK PLYWOOD 4"H WiTH P-LAM COVER °J l___J__1_._ 1 • ` 1- - -- �--'I , I I`...�U I I IP, I Irk..,-... � I � � �O ', --f - �; �, r---e--• ---�i �, - ! 4. DOORS AND DRAWER FRONTS PRE LAID PLASTIC LAMINATE OVER 11/10" PARTICLE BOARD WITH MATCHING P-LAM OR PVC p vii Q 7 I 11 I I II p i I II II I 1 I -- -,�-- i EDGES. O 3 (1. T I C.J F' I I I + 8 2) TUBE FLOURSCENT 5. MELAMINE (LOW PRESSURE LANIINATE/ LPI.,) ALL INTERIOR AREAS, DRAWER PARTS, SHELVING ETC. FIXTUEs iN WARENOU5E LOADING e„ - 1 -I _ ' �77 1 - i �� � I I I I I L_1 1 6. FLUSI I OVERLAY/FRAMELESS STYLE CONSTRUCTION. 1l DL , -- - � __�.__I��:�...._ 1.__1_ I I REVISION C\A I 1 _.If F - -I I I� ` � I I Ir, 11 7 r .ISP---�.- I II \ II I I IIS 1-1-4 -I --yli �, h--- 7. HINGES - BLUM #75M3580 110 DEG. SELF CLOSING CLIP ON (OR EQUAL). ' 1 I +' • • I I I • I I I I I I • i 1 ----- -r - - 'l i D 0 C I , H I u H O N 8. DRAWER SLIDES - BLUM #230M SERIES EXTENSION (OR EQUAL) 75 LBS. MIN. FOR STANDARD DRAWERS. ACCURIDE #4032 (OR I _ - - - 1-- I --h --I- -1 - ►-- i -- ,•..__k� L_._I _....I-.. I EQUAL)l ID/FULL EXT 150 LBS. MiN. FOR HD AND FiLE DRAWERS. -� - _ i__.i__ + I - I. - - - 9. PULL, 96 lviM CTO C WI RE DULLS. 605 POL1Sl iED BRASS. _5 - - 6 - - ' 10. GENERAL CON-TRACTOR TO PROVIDE CABINET MAKER WITH SiNK TEMPLATE (SPEC SHEETS) FOR EACH SINK. SINK CUTOUT I _ OS - _ _ I WILL BF, DONE 1N Si '.OP WHEN FEASIBLE AND BEFORE BACK SPLASFI IS INSTALLED IN ALL CASES. (THIS ALLOWS CUT OUT TO 1 BE POSITIONED PROPERLY.) RAW EDGES OF C'U'T OU'C AND BACK SPLASH '1'O BE SEALED. MINIMIZE COUNTERTOP BUILD UPS AT I I I i 1 N N I FRONT' AND BACK OF SINK CUT OUT TO ACCOMMODATE PLUMBERS SINK CLAMPS CLEARANCE. i (F. i - - -- - 11. KlTCill,N/131ZEAK ROOM CABINETS - BASE CABINET WITH P-LAM TOP ON PLYWOOD DECKING AND 4" BACK SPLASH. ALL DATE; 8/15/03 1 CABINE'T'S WiTH DOORS AND DRAWERS, U.O.N. UPPERS 1'2" D X 36" H, COUNTER AND COUNTERTOPS 26" D. MICROWAVE SHELF 18"D WiTI1 3" RADIUS OUTSIDE CORNERS. P-LAM TOE/BASE SKINS. ALL SHELVES AD,I. HOLES AND POSTS (1 AT BASE, 2 AT �- �equola Pkwy Suite140, 15055 BUP2003.00502 II - -- - - 3 of 4 12. WORK/COPY/S'T'ORAGE CABINETS - 13ASE CABINET'S WITH P-LAM TOP ON PARTICLEBOARD DECKING. SCRIBE TOP TO WALLS. ALL CABINETS OPEN MELAMINE STANDARD INTERIORS W}TH DRAWERS, U.O.N. UPPERS 15"D X 30"H. BASES 24"D X 36" H AT COUNTER AND COUNTERTOP. P-1_,AM 'TOE/BASE: SKINS. ALL, SHELVES ADI. HOLES AND POST ( I AT BASE, 1 AT UPPERS). .�.� 13. RESTROOMS/LAVS - 24"D P-LAM TOP ON PLYWOOD DECKING WITH 4"f l P-LAN1 BACK SPLASH. 5"H FACE MOUNT AT 341, A.F.F. SCALE: Ile;" I' n„ 1 u EGRESS PATH PROVIDE MIN EMERGENCY LIGHTWG W/BATTEP`' BACK uP TO I FOO•I CANDLE P-L.nM WAINSCOT 48"}}. SEE PLANS IF RF.0>TJI}ZED, I �.}. b I NOTICE: IF THE PRINT OR TYPE ON ANY rCr I l r i l i i l l l i l i ;I i I i l i i i IIIA 'llllIIIIII�I11��iilllill�fllllll I IIiI � � i� Illlill Ilili �l III � I I i � illli Illlill Ili iii ili , i � � Ilili �� i �illli i � iJilill � tllll ilifl � i � lili i / a'1� Ck�� � IMAGE IS NOT AS CLEAR AS THIS NOTICE, lI -- I- - - 1-- --- ' 1-- �( - 61 _ _ --- �. - ----I --$I �I I IO ZZ I 1 OA M..» •.....•+�.r»wyW+99Y1M1m IS DUE TO THE (QUALITY OF THE No,,e ®��-���• "-•�' ORIGINAL DOCUMENT £ F+Z 8Z L1Z 9Z 9�Z I ib1Z £Z ZZ iZ OZ tai 8l L�I 9I 4I 6l]. bT ZI TI i t3 8 L 19 4 ���������►I�►I����� ►�I� II�I��I�II►II���I��llll����►I�►���������������►I�!���� ��►����������►I►��� ►��Il►��► ��►I�I��� ��Ill�l 111� 1����11��1► 1111► I I�� I III �� III�III IIII III�lf I�IIII�IIII�IIlllllll�l►lllllll�lllllllll�lllll f I V I I I IlilL111111111111�111Il�lll.11ll�1111111111111111111 � 15' -Im' Il'-II° I0'-4" 4'-00 � PROJECT #03330 L'= �I \= J ADJ SHEL - - MICRO 1�SPACE5 �I Ex15TING DJ SNE =_ _ _ _ __ _ = _ __ w RELIGHT - - nl c , I 11 I WAVE _iN u I - -I'� - Ir - II - - J _ JL JL J Kt L - - - 4) COIAL SPACES 0 COUNTER 24' DEEP cv ADJ SHELVES N $ I 11 - I I I I ^i I6' DEEP I I/ I D I R 1 �I�, , IL - - - - 14'-ra' 6) • 28' b) EQUAL SPACES _ I h 2 Off Z G � WALL I I IT 123 EAST WALL 4 IT NORTH WALL BREAK 118 EAST RECEPTION 101 SOUTH2 RECEPTION 101 EAST WALL 3 41-0' O 21'-6" 28 3 gl 4" I II y 1� Imo— 1 I -- 2 D -0 — — - lli SPACES ppJ 9HE �, ADJ SHE OPENING TO 11 w I _ _ _ S OPENING TO - OPEN OFFICE -,IOPEN OI`FiGE 10 END n� '0 N � 112 TO CIRC ° ��F------ili hh--11 tt � (20 OPENING II -I� COPY MACHINE _ c -- _ - - - - - - - - - - - - - - - - - - - - ADJ SHE F IE_ _ D _ _ _ y _��- ADJ S = F _ L - _ JL - . JL. _ JL _ 7 2'-4' - I I II'-8" 5 9 2' 4' (0 1-01 — A LL 8 WO 119 SOUTH WALL 9 WORK 119 ISLAND 21' -3" �i G� SH ADJ SHEL GLASS uLASS GLASS GLASS GLASS W c*1 7 ; D TO W AREHOUSE 134 DOUBLE a x t ACTING BACK SPLASH SINK r M1 _ v N. - ADJ SHELF . JL _ _ JI IL J W o 14'-m' 90 ® 2'_4' 1 15'40" LABORATORY EAST WALL 12 LABORATORY SOUTH WALL 10 LABORATORY NORTH WALL 11 IS'-ON 23'-3" _ REVISION — I. 3. 1- 7 JL NL ADJ SHEL: _ -_ - ADJ NEL - - -_ _ -_ - - _ _ _ _ = ADJHEI_' 4. 5. DOOR 6. �Q DOOR TT� I I I I I I I I I I I I I I I I I I I OPENOFF�CE LAB 133 L_ _ JL ._ _JL _ _ JL - /-- JL_ _ JL _ _JL _ _ J _ L _ _ .JL _ _ JL , _ JL _ _ JL _ 128 \ - DOUBLE -- 4 - -JL - ACTING — -- -- - - - - - - - - - SINK BACKSPLASH _ ct` 3ji 1—( II / DATE: 8/15/03 ADJ SHELF IV, 11 — y / — Se.luole Pkwy.Suile140. 15055 0140 i-/ II __. I I I 40" 1) 6 2'-(9' — 15'-�p 6) , 2�-b' 0 of P20030050Y 13 LABORATOhY WEST WALL 15 WAREHOUSE 129 SOUTH WALL 16 WAREHOUSE 129 SOUTH WALL NOTICE: IF THE PRINT ORTYPE ONANY i _ f�rll r i dill lllllll l�ttl l IlllTrl lllftl iTiT iTJT TIIIfl71'tTiT i t't (IIII I IIIIIII III I I IIIiTjj11t J1111111 IMAGE IS NOT AS CLEAR AS THIS NOTICE, IIII I II 13 ` I , �Ir I �' I �bl � IT IS .SUE TO THE QUALITY OF THE ORIGINAL DOCUMENT i t tli l6 S t 1 ��t IIII�IIt T t t t �II �Ot II� I L I 9 9 I 6 t � IIII IIII�IIII IIII�IIII IIII�IIII IIII�IIII IIII�IIII Wl�llll �Illl III�UII III III Il��llll IIII�IIII IIII�IIII IIIIIIIII tin II�IIII IIII1IIII IIII�IIII IIII�IIII III, Uil IUUW llllut< lllu�l Il1l�llll uu uulllul,Ill uu uu un llu lm uu IIII IIII IIII 81I