Loading...
Report i Product FLINTLASTIC modified bitumen roofing systems shall be applied in accordance with installation Application procedures contained in the CertainTeed Commercial Roof Systems Manual. The following information is intended for general information purposes only and is not all-inclusive. Preparation:Substrates to receive a roof system shall be firmly attached, smooth, dry, clean and free of sharp projections and depressions. Substrates requiring priming shall be primed with asphalt primer such as CertainTeed's FlintPrime-and be allowed to completely dry. Substrates shall provide positive drainage. Roof shall be tapered to drains. Installation: Install one ply of GLASBASE or other CertainTeed approved alternate base sheet lapping 2" on sides and 4" on ends. Base sheet shall be mechanically fastened to nailable substrates, and either solid or spot mopped in hot asphalt to non-nailable or insulated substrates as specified in the CertainTeed Commercial Roof Systems Manual. Apply base sheet in such a manner to provide and maintain a minimum 6" offset between side and end laps of base ply and FLINTLASTIC finishing membrane. Over the base ply, install one ply of FLINTLASTIC GTA lapping 3" on sides and 6" on ends with end laps diagonally staggered not less than 3 feet apart. Side and end laps should be inspected to ensure a minimum 3/8" flow of modified compound has been achieved. Precautions:Cold weather applications require special handling to prevent damage to the rolls and to ensure satisfactory installation. Do not apply roofing systems over improperly prepared substrates or substrates which contain moisture. Follow all safety recommendations relating to the use and maintenance of liquid propane gas torches and equipment. Refer to the CertainTeed Commercial Roof Systems Manual for additional safety information. Maintenance:FLINTLASTIC Roof Systems do not require any additional maintenance beyond normal yearly roof maintenance procedures. CertainTeed recommends regular roof maintenance and inspection to determine the condition of drains, flashings and other similar items, and to prolong the life expectancy of the roof system. Warranties CertainTeed offers a number of different types of Roof Membrane Warranties designed to meet the building owner's specific requirements. Please contact your nearest CertainTeed office for additional information and requirements. Technical CertainTeed provides technical assistance in the design, selection, specification and application Assistance and guidelines for all CertainTeed Roof Systems. Architectural and field representatives are available for Services consultation within each region. For more information, contact CertainTeed's Customer Support at 800-233-8990. Caution: Torch application of this product may create a risk of FIRE, including SMOLDERING FIRES. Fire Hazard The roofing applicator is solely responsible for ensuring and enforcing safe and proper application of CertainTeed's roofing products by competent and qualified personnel. Only properly trained roofing professionals are authorized to install this product. Never apply flame directly to combustible materials or allow the flame to enter into hidden or protected areas that may contain combustible materials. Follow all local code requirements. Have a Class A-B-C fire extinguisher available to each applicator. Thoroughly inspect the job site whenever torching equipment has been used. Be certain that all chances of a fire have been eliminated. Refer to the CertainTeed Commercial Roof Systems Manual, Midwestern Roofing Contractors Association (MRCA) CERTA program, National LP Gas Association, National Roofing Contractors Association (NRCA), National Fire Protection Association (NFPA), and Asphalt Roofing Manufacturers Association (ARMA) for further information and safety recommendations. ASK ABOUT OUR OTHER CERTAINTEED PRODUCTS AND SYSTEMS: EXTERIOR: ROOFING • SIDING • WINDOWS • FENCE • RAILING • TRIM • DECKING • FOUNDATIONS • PIPE INTERIOR: INSULATION • GYPSUM • CEILINGS CertainTeed Corporation Professional:800-233-8990 Box r wwwcertainteed.com CertainTeed El Valley Forgee,,PA 19482 0 2000 Rev 11/09 CertainTeed Corporation,Printed in U.S.A. - Code No.COMM-020 SPECIFICATION: CertainTeed GTA N B2 MAX.WARRANTY DURATION SAINT-GOBAIN • 12 YR NDL SECTION 07550 t ONE PLY OF GLASBASE'BASE SHEET, ONE PLY OF FLINTLASTIC®GTA Inclines: Up to 6"in 12"(inclines 2"to 6"in 12"See General Requirements/Nailing Section). FOR USE OVER NAILABLE DECKS (FOR LIGHTWEIGHT INSULATING CONCRETE DECKS, SEE Roofing Membrane. GENERAL REQUIREMENTS SECTION PARAGRAPH 3.9) The base ply is installed with approved mechanical fasteners in the side laps, 9" o.c., and two rows staggered in the center of the sheet, 12" from each i 4"End Lap p Nailable Deck edge and 18" o.c. Laps shall be a minimum of 2" on II sides and 4" on ends. If using APP Base T, laps shall be Sheathing Paper 393/8° , , a minimum 3" on sides and 4"on ends. These laps must (If Required) End Laps be heat-welded. Install base ply to provide and maintain Staggered • -- 3'Apart(min) a 6" minimum offset between the side laps and end laps t YV 41 respectively of the base ply and the FLINTLASTIC® GTA Drainage 2"Lap ' + , ' Field Membrane. Torch apply one ply of FLINTLASTIC® 1.-18°-4 • GTA over the base ply. Laps shall be a minimum 3" on f sides and 6" on ends. All end laps shall be diagonally -�-• •�', • 3"Lap • • ' . staggered and not less than 3' apart. All side and end • 1 ,,. 393/8 6" caps of each ply shall be staggered and offset from 1 End-+� 19'/16° 'i i• , , Lap , preceding plies. Roofing system shall be applied in a I - 'i 1 ; continuous application. ` I Nails • , 1 • , Base Flashingand Curbs. Glasbase All Weather/Empire Flintlastic GTA Over the completed membrane at vertical surfaces, Flexiglas Base Flintlastic GTA CoolStar install base flashing consisting of one ply of Flintlastic® Flintlastic Base 20 PCap Sheet torch applied to primed concrete or masonry SMS Ultrraa Poly SMS surfaces. Base flashing shall extend a minimum of 8" up Yosemite GTA-N-B2 vertical surfaces and 4" out onto field membrane. Wood surfaces shall receive one ply of base sheet extending from top of cant strip to top edge of Base Flashing prior 2.01 ROOFING SYSTEM to application of Flintlastic®Cap Sheet. Nail top edge Summary of Materials per 100 Square Feet. of Base Flashing 9" o.c. through tin-discs. Sealing the top of the base flashing prior to installation of tGLASBASE'" Base Sheet(1 ply) 25 lbs. counter-flashing is recommended. FLINTLASTIC®GTA roll roofing (1 ply) 105 lbs. Final Surfacing. Approximate Total Weight without Refer to General Requirements Section for information optional surfacing 130 lbs. on reflective coatings and optional surfacing. Cants. Refer to Commercial Roofing Systems General In angles of roof deck and vertical surfaces, the Roofing Contractor shall furnish and install an approved Cant Strip Requirements Sections for definitions. General with a minimum 3"face. Requirements shall be used in conjunction with Roof System Specification. Insulation and/or NOTES: recover specifications require the integration of tAlternate approved CertainTeed Commercial base sheets appropriate addenda into the main specification. include: FLEXIGLAS`", FLINTLASTIC'" BASE 20, ULTRA POLY SMS, ALL WEATHER/EMPIRE, POLY SMS or YOSEMITE. 1/12 VIII-25 t rp' ( ',$ •' . Performance Vr1 I E611 F414 W i'I 1 4.ki ° , i Hutt • `x, ig uildi g Products � "� ,,,� - • gii .7 x, .'r., i4 e�w "' . P �t a t construction, Inc .. $ "1j w �' y r'" * x wy� `jam f r ` >'1l` �k^>, y ''''' .1 alli..''' ' .. .!.'0.f*, it Of • .A• . • , • ' t- �. HunzikerbStreet '^ y fi . Mr 7 `a[ »soh` > t • .h i / $ 44' s`. �e' ' \ ..--74%, ' - 141 4110ONLINE CERTIFICATIONS DIRECTORY TGFU.R11656 Roofing Systems Page Bottom Roofing Systems See General Information for Roofing Systems CERTAINTEED CORP R11656 ROOFING PRODUCTS GROUP 20 MOORES RD MALVERN,PA 19355 USA "1/2-in. thick(minimum) gypsum board or 1/4-in.thick(minimum) Georgia-Pacific Gypsum LLC"DensDeck® Roofboard" or"DensDeck® Prime Roofboard"or"DensDeck® DuraGuardTM Roofboard"or 1/4-in. thick(minimum) United States Gypsum Co. "SECUROCK® Roof Board" (Type FRX-G) or"SECUROCK®Glass-Mat Roof Board" (Type SGMRX) may be used in any existing noncombustible deck Classification. When this is done,the resulting roofing system is acceptable for use over combustible(15/32-in. thick minimum) roof decks. However,the butt joints in the gypsum board and Georgia-Pacific Gypsum LLC"DensDeck® Roofboard"or"DensDeck® Prime Roofboard"or"DensDeck® DuraGuardT" Roofboard" are to offset a minimum of 6-in. with the butt joints in the roof deck. If polystyrene is part of the roof system, it must be placed below the overlayment board. 1/4-in.thick(minimum) United Sates Gypsum Co. "SECUROCK® Roof Board" (Type FRX-G) and "SECUROCK® Glass-Mat Roof Board" (Type SGMRX) are limited to a maximum 3:12 slope when used over a combustible roof deck in a system with any UL Classified insulation except polystyrene." Any UL Classified insulation may be used underneath 1/2-in.thick(minimum) gypsum board or 1/4-in. thick(minimum) Georgia-Pacific Gypsum LLC"DensDeck® Roofboard"or"DensDeck® Prime Roofboard" or"DensDeck® DuraGuardTm' Roofboard" or 1/4-in. thick(minimum) United States Gypsum Co. "SECUROCK® Roof Board" (Type FRX-G)or"SECUROCK® Glass-Mat Roof Board" (Type SGMRX) in any existing noncombustible deck Classification. Mineral Wool Felt, is a suitable alternate for perforated Type 15 asphalt organic felt in the Class A, B or C roof constructions indicated below. Type G1 "Flintglas Ply Sheet'Type 4 or"Flintglas Premium Ply Sheet"Type 6 are suitable alternates for Type 15 organic felt; Type G2 "Glasbase Base Sheet" is a suitable alternate for Type 15 and Type 30 base sheets; Type G3 "Flintglas MS Cap" is a suitable alternate for Type 30 Cap Sheets. "Flex-I-Glas", "Premium Flex-I-Glas" or"Flintlastic Base 20 Sheet" is a suitable alternate for the Type G2 glass base and the Type 15 "All-Weather/Empire base sheet". Unless otherwise indicated, base sheets are mechanically fastened or spot mopped in place; ply and cap sheets are hot mopped in place. Two plies Type G1 may be utilized in place of one ply Type G2. "Flintlastic Ultra Glass SA" is a suitable alternate for Type G2 "Glasbase Base Sheet". "Black Diamond Base Sheet"is a suitable alternate for Type G2 "Glass Base Sheet". "Flintlastic SA Nailbase"or"Flintlastic SA Plybase" are suitable alternates for Type G2 base sheets in Roofing Systems (TGFU)that limit cover applications to self-adhering ply/base sheets or membranes. EPS insulation followed by 1/2-in.thick cover board may be utilized in any of the following systems. The"YOSEMITE Venting Base Sheet" may be used in any of the following noncombustible deck roof systems and,where indicated, in combustible roof deck systems. "Torch APP" may be utilized in any of the following systems that contain "Flintlastic STA". Flintlastic APP Base T is a suitable alternate for any Type G2 base sheet. "Flintlastic Ultra Poly SMS" may be used in lieu of"Poly SMS Base" in all application Classifications. References to Type G2 base sheets includes "Channel-Vent GB". "FlintBoard Iso", "FlintBoard Iso Cold", "FlintBoard Iso-T" or"FlintBoard Iso Plus", may be used wherever polyisocyanurate insulation is specified. Uniform thickness or tapered insulation may be used in the following systemsprovided they do not exceed the indicated incline or thickness. "FlintBoardH ISO", "FlintBoardH ISO Cold", "FlintBoardH ISO WF", "FlintBoardH ISO F", "FlintBoardH ISO NB" and "FlintBoardH ISO DD" may be used wherever polyisocyanurate insulation is specified. "FlintBoardH ISO T", "FlintBoardH ISO T Cold" and "FlintBoardH ISO T WF"are acceptable alternatives to"FlintBoardH ISO", "FlintBoardH ISO WF"and "FlintBoardH ISO Cold", respectively, provided they do not exceed the indicated incline or thickness of the system. Any'UL Classified EPS, any thickness, may be used below "FlintBoardH ISO", "FlintBoardH ISO T", "FlintBoardH ISO Cold", "FlintBoardH ISO T Cold", "FlintBoardH ISO WF", "FlintBoardH ISO T WF", "FlintBoardH ISO F", "FlintBoardH ISO NB"or"FlintBoardH ISO DD"insulation on non- combustible decks provided a minimum 1-in. thick layer of"FlintBoardH ISO", "FlintBoardH ISO T", "FlintBoardH ISO Cold", "FlintBoardH ISO T Cold", "FlintBoardH ISO WF", FlintBoardH ISO T WF", "FlintBoardH ISO F", "FlintBoardH ISO NB"or"FlintBoardH ISO DD" polyisocyanurate 69. Deck: NC Incline: 1 Insulation: — Polyisocyanurate,glass fiber, perlite,wood fiber, mechanically fastened or adhered with hot roofing asphalt, any thickness. Base Sheet: — "Black Diamond Base Sheet", self-adhered. Ply Sheet: — "Flintlastic STA"or"Flintlastic APP Base T", heat fused. Cap Sheet: —"Flintlastic GTA-FR", heat fused. 70. Deck: C-15/32 Incline: 1 Insulation: — Minimum 2-in. thick polyisocyanurate insulation. Base Sheet: — "Black Diamond Base Sheet", self-adhered. Ply Sheet: — "Flintlastic STA"or"Flintlastic APP Base T", heat fused. Cap Sheet: — "Flintlastic GTA-FR", heat fused. Class B-Fully Adhered 1. Deck: NC Incline: 1 Vapor Retarder(Optional): —Type G2 "Glasbase" base sheet or UL Classified vapor retarder. Insulation (Optional): —One or more layers or combination of the following: UltraGard Premier, polyisocyanurate, perlite,glass fiber or wood fiber insulation. Base Sheet: — One layer Type G2 "Glasbase" base sheet. Membrane: —One layer"Flintlastic STA" (modified bitumen), heat fused. Surfacing: — "FlintCoat-A150"or Karnak Corp"97AF"applied at 11/2-gal./100-ft2. 2. Deck: C-15/32 Incline: 1/4 Vapor Retarder(Optional): —Type G2 "Glasbase" base sheet or UL Classified vapor retarder. Insulation (Optional): —One or more layers UL Classified perlite or glass fiber. Base Sheet: — One layer Type G2"Glasbase" base sheet. Membrane: — One layer"Flintlastic GTA,GTS" (modified bitumen), heat fused or"Flintlastic GMS", hot mopped. Surfacing: —APOC"No. 212 Fibrated Aluminum",applied at 11/2-gal./100-ft2. 3. Deck: C-15/32 Incline: 1/4 Vapor Retarder(Optional): —Type G2"Glasbase" base sheet or UL Classified vapor retarder. Insulation (Optional): —One or more layers or combination the following: Ultragard Premier, polyisocyanurate, perlite, glass fiber or wood fiber insulation. Base Sheet: —Two layers Type G2 "Glasbase" base sheet. Membrane: —One layer"Flintlastic STA" (modified bitumen), heat fused. Surfacing: — "FlintCoat-A150"or Karnak Corp "97AF"applied at 11/2-gal./100-ft2. 4. Deck: NC Incline: 2 Insulation: —Glass fiber, perlite, wood fiber, 21/2-in. maximum thick, mechanically fastened or adhered with hot roofing asphalt. Base Sheet: —Type G2, mechanically fastened or adhered with hot roofing asphalt. Membrane: — "GMS", "GMS Premium",adhered with hot roofing asphalt. Surfacing: — "FlintCoat-A150"or Karnak Corp "97AF"applied at 21/2-gal./100-ft2. 5. Deck: C-15/32* Incline: 1/2 *All joints blocked with 2x4's. Insulation: —Glass fiber, perlite, 3/4 to 21 in. thick,joints in insulation must be offset a minimum of 6-in.from butt joints in roof deck, mechanically fastened. Base Sheet: —Type G2, mechanically fastened or adhered with hot roofing asphalt. Membrane: — "STA", "GTA", "GTA Black Diamond"or"GTA White Diamond", heat fused. Surfacing: — "FlintCoat-A150"or Karnak Corp "97AF"applied at 11/2-gal./100-ft2. 6. Deck: C-15/32* Incline: 1/4 *All joints blocked with 2x4's. Base Sheet: —Type G2, mechanically fastened. Membrane: — "STA", "GTA", "GTA Black Diamond","GTA White Diamond", heat fused. Surfacing: - "FlintCoat-A150"or Karnak Corp "97AF"applied at 11/2-gal./100-ft2. 7. Deck: C-15/32* Incline: 1/2 *All joints blocked with 2x4's. Base Sheet: —Type G2,nailed. Membrane: — "GMS", adhered with hot roofing asphalt. Surfacing: — "FlintCoat-A150" or Karnak Corp "97AF"applied at 21/2-gal./100-ft2. 8. Deck: C-15/32* Incline: 1/4 *All joints blocked with 2x4's. polyisocyanurate/composite or Partek Insulation "PAROC" roof insulation. Base Sheet: —One or more layers Type G2. Membrane: —One or more layers "Flintlastic GTA" or"-STA" (modified bitumen), heat fused. Surfacing: — Fields"F530 Heat Shield Aluminum Coating" or"F630 Heat Shield Fibered Aluminum Coating", 11/2-gal./100-ft2. 18. Deck: C-15/32 Incline: 1/2 Insulation (Optional): —Polyisocyanurate, 2-in. minimum, glass fiber 1-in. minimum. Base Sheet: —One or more layers Type G2 "Glasbase", mechanically fastened. Membrane: —One layer"GTA/FR" (modified bitumen),torch applied. 19. Deck: C-15/32 Incline: 1/2 Base Sheet: —One or more layers Type G2, mechanically fastened. Membrane: One or more layers "GTA" (modified bitimen), heat applied. 20. Deck: C-15/32 Incline: 1/2 Base Sheet: —One or more layers Type G2 "Glass Base", mechanically fastened. Membrane: — One layer"Flintlastic GMS", hot mopped or"Flintlastic GTS" (modified bitumen), heat fused. 21. Deck: C-15/32 Incline: 1/2 Insulation (Optional): —Any thickness, one or more layers UL Classified perlite,glass fiber, polyisocyanurate, Barrier Board: — Minimum 1/4-in. thick Geogia-Pacific Gypsum LLC Corp. "DensDeck® Roofboard"with all joints staggered a minimum of 6-in,from the plywood butt joints. Base Sheet(Optional): —One or more layers "Flex-I-Glas", mechanically fastened. Ply Sheet: —One or more layers "Flintlastic Ultra Poly SMS", heat fused. Membrane: —One layer"Flintlastic GTS", heat fused. 22. Deck: NC Incline: 1/2 Ply sheet: — "Flintlastic Ultra Glass SA" Membrane: — "FR-P membrane",fully adhered with Karnak Corp. "81 Brush" adhesive at 11/z-gal./100-ft2. 23. Deck: NC Incline: 1/2 Ply Sheet: — "Flintlastic Ultra Glass SA" Membrane: — "FR-P membrane hot mopped. • 24. Deck: C-15/32 Incline: 1 Base Sheet: — One layer Type G2 or"Flexiglas", mechanically fastened. Surfacing: — "Flintlastic Cap 30",hot mopped. 25. Deck: NC Incline: 1/4 Base Sheet: — "Flintlastic APP Base T", mechanically fastened or torched Ply Sheet(Optional): — "Flintlastic APP Base T",torched Cap Sheet: —"Flintlastic GTA",torched 26. Deck: NC Incline: 1/2 Barrier Board: Minimum 1/4-in.thick United States Gypsum Co. "SECUROCK® Gypsum-Fiber Roof Board" (Type FRX-G), mechanically fastened. Ply Sheet: - "Flintlastic STA"or"Flintlastic APP Base T", heat fused. • Cap Sheet: — "Flintlastic GTA", heat fused. 27. Deck: NC Incline: 1-1/2 Insulation: — Polyisocyanurate, glass fiber, perlite, wood fiber, mechanically fastened or adhered with hot roofing asphalt, any thickness. Base Sheet: — "Black Diamond Base Sheet", self-adhered. Ply Sheet: — "Flintlastic STA"or"Flintlastic APP Base T", heat fused. Cap Sheet: — "Flintlastic GTA-FR", heat fused. • • Class C-Fully Adhered 1. Deck: C-15/32 Incline: 1/2 Insulation (Optional): — Polyisocyanurate, perlite, wood fiber or glass fiber, mechanically fastened or hot mopped in place. Base Sheet: — One or more layers Type G2 or"Flex-I-glas", mechanically fastened or hot mopped in place. Ply Sheet(Optional): —One or more layers Type G1,Type G2, "Flex-I-Glas"or"Poly SMS Base Sheet", hot mopped in place. Membrane: — "GMS", "GTA", "GTA Black Diamond" or"GTA White Diamond", heat fused. 2. Deck: C-15/32 Incline: Unlimited Impact: 4 Insulation (Optional): —Wood fiber, glass fiber or perlite, any thickness. Base Sheet: — One layer"Flintlastic SA Nailbase ", mechanically fastened. Cap Sheet: —One layer"Flintlastic SA P-Cap FR",self-adhered.