SGN2017-00006 CITY OF TIGARD SIGN PERMIT :� s Permit#: SGN2017-00006 COMMUNITY DEVELOPMENT Date Issued: 01/05/2017 T I G A k P 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Parcel: 2S112AD01100 Jurisdiction: Tigard Name of Business: Mattress Firm Business Address: 6650 SW BONITA RD Applicant/Agent: Kayser, Tina Work Description: One(1)new 121.5-square-foot wall sign. Single element greater than 20 pounds. Permanent: Yes Freestanding: No Freeway: No Temporary: Wall: Yes Electronic: Yes Billboard: No Balloon: No Banner: No A-Board: No Sign Dimensions: Total Sign Area: 121.5 Wall Area: 2200 Wall Face(Direction): North Sign Height: 19 ft. Projection From Wall: 5 in. Illumination: Internal Materials: Aluminum, vinyl, LED Electrical Permit Required: Yes Building Permit Required: Yes Total Permit Fee: $201.00 Conditions: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. A permanent sign must be placed within 90 days from approval date or sign permit shall expire. A temporary sign shall expire 30 days from validity date. A balloon sign shall expire 10 days from validity date. -24 Approved By: Permittee Signatur " RECEIVED City of Tigard JAN 0 5 2017 COMMUNITY DEVELOPMENT DEPARTMEdy(1IY OF TIGARD g n A- • PLANNING/ENGINEERING TIGARD Sign Permit Application SIGN LOCATI(O I (` REQUIRED SUBMITTAL Address: S J Ir(J )J on ( uite#: ELEMENTS Ci state:l/,t1 V a ore-- Zip: ! 7LL y City/state: lip �'' 2 copies of elevations on 81/2"x 11 Tenant or business: m i(tilt S 1 /7 rill or 11"x 17"pages(Wall sign ) elevations must include dimensions Property owner name: Pauf l Pi/� h Q//L of sign and wall face and show the location of sign on the wall. Address: Freestanding sign elevations must City/state: Zip: drawn to scale.) Phone: Email: pies of site/plot plan,drawn to scale,on 8t/2"x11"or 11"x17" /pages(not required for wall signs) Sign contractor: kg Ms , .17/Z//7 f y(1J 9/ a jl f y/� ,q�/ List or diagram of all existing sign Address: �/� r 'mensions and square footage City/state: Df''I t2n d Zip: q 7 L a Application Fee Phones -777 %J TTEmail: iI f'. rr, CCB License #://32- Z Expiration date: v/ NOTES: Contact person: /11 ih' f'(qf-0 y • Freestanding signs over 6 ft.in height and walls signs of which any element weighs 20 lbs.or more require a SIGN DATA(Complete all items in this section) building permit for construction. If any element of a wall sign weighs 70 lbs.or more,plans must be prepared TYPE (Check all that a ply) by a structural engineer. New sign ❑ FreestandingElectrical • Building permits require 2 sets of 0 Alteration to 0 Freeway Wall construction drawings and,if sign is freestanding,2 copies of site/plot plan existing sign 0 Roof 0 Other and 2 sets of engineering must be Sign#: submitted with building permit application. Sign dimensions: J 3 'I (h) x it l 1Z I.-i4ft. sign area New sign: sq.ft. + Existing sign area sq.ft.= Total FOR STAFF USE ONLY Total sign area:i L 1 sq.g/ -144g lding face sq.ft.=S.S%of bldg face Q0 �' / Case No.: 1.(. Height to top of sign: I ., ift)Proje tion from wall: Sin. Related Case o.(s): Materials: 1�1�1M J 1 n I i 11/'( Fee: 02 0, Application accepted: i 1}-� Is the sign under 20 lbs.? ► JKes No By: 1.--� /Date: // // 'Tr (Building Permit required if over 20 lbs Direction wall faces (circle one): 1bs� S E W NE NW SE SW Applicati1 d�e'terminD complet Will the sign have illumination?? Yes 111 No By Date: /� 1 - If yes,what type: Internal ❑ External 1:\CURPUJ\Masten\Land Use Applications Rev.03/03/2015 City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov • 503-718-2421 • Page 1 of 2 APPLICANTS NOTE: Person specified as"_Applicant"shall be designated"Permittee"and shall provide financial assurance for work. •\L hen the owner and the applicant ace different people,the applicant must be the purchaser of record or a lessee in possessu,n with written authorization from the owner or an agent of the owner The ownerts)must iign this application in the space provided on the back of this form or submit a written authorization with this application. THE APPLICANT(S) SHALL CERTIFY THAT: • If the application is granted,the applicant will exercise the rights granted in accordance with the terms and subject to all the conditions and limitations of the approval. • All of the above statements and the statements in the plot plan,attachtnents,and exhibits transmitted herewith,are true;and the applicants so acknowledge that any permit issued,based on this application,may be revoked if it is found that any such statements arc false. • The applicant has read rhe entire contents of the application,including the policies and criteria,and understands the requirements for approving or denying the application. I hereby acknowledge that I have read this application,that the information given is correct,that I am the owner or authorized agent of the owner,and that plans submitted are in compliance with the City of Tigard. SIGNATURES of each owner of the subject property required. /i l r 4 ; ire ei1 /i,,, / << /�; �.z'/iG-/A-- App.lant's signature Print pame Date . ' ___._ ACC 4. / .. —tom T( i y/ �7 Owner's signature J Print name D te Owner's signature Print name Date SIGN PERMIT APPLICATION City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov • 503-718-2421 • Page 2 of 2 SIGN A 33" Mattress Firm linear • Type: Channel Ltrs w/Backer on a Raceway SLEEPit TRAIN 11 i„,,,,. Illumination: Internally Illuminated LEDif Square Footage: 121.50 IN I J`' NATES: irtior- Remove existing channel letters. Patch&repair facade L - Manufacture and Install new signage Existing RECEIVED CITY OF TIGARD JAN 0 5 2017 Approved by PI nning Date: CITY OF TIGARD I nitials: _______/.2-_ PLANNING/ENGINEERING ± 100'-0"Lease Dimension 32'-0"Sign Band ii, 28'-83/4" iFQ 4 o 'lc - MATTREssFIRM a , it l''' a c? _ ,i s , ,, , N ,fib , T .. Olt' , _ �y , 7 * Via, ' ;'. iii .4.0.0*,- IIMNiiiliIllaIIIPIMIMM$11 Front Elevation (North) Scale: 3/32" = 1'-0" Allowable Square Footage this Elevation: 225.00 225.00 Actual Square Footage this Elevation: 121.50 3 Mattress Firm Project ID#: 110971 R1 10/14/16 EHRemoved awnings _ ri,epity for hicnitaasintendea.n recw sT: p R2 10/15/16 EH Added awnings back AlPille"SIGN '"®anuno°bllshedoriginaldrawingnottobedist- Tigard South Project Mgr: Denise Childers ( R3 11/18/16 MD Added directional. changed awning color&pylon color ` con e n reproducedor roup ed without thectopt pouR axou�n manager A orque r6asr gardin coinstatitirient t 6650 SW Bonita Road Designer: Kirk Forster W84.11/21/16 EH_Removed awnings G R o u Papexsigngroup.com Tigard, OR 97224 Created on: 10/13/2016 — — - SIGN A 33" Mattress Firm linear Type: Channel Ltrs w/Backer on a Raceway / 28'-8 3/4" [344 314"] / Illumination: Internally Illuminated LED / 28'-4" [340"] / Square Footage: 121.50 / 1111/2" co SIGN B 33" Mattress Firm linear (NI Type: Channel Ltrs w/Backer on a Raceway Illumination: Internally Illuminated LED Square Footage: 121.50MATTREss FiRm M CD � 3 /‘ 1 05 SoLtai ' ,46,,e) Sign Layout Detail , r Scale: 1/4" = 1'-0" 1 O ti— f° 1)it/REG[ CiTY 0 F TIGARD / 5" I 7114° P nning 1 �7 16 Approved y� \ • JAN 0 5 201, Date: Initials: / S O 10 ; CITY OF TIGARD PLANNING/ENGINEERING' 3 ® 10 3 _ __ 0 Electrical Detail: Specifications: Channel Letters w/ Backer on Raceway i .OW White LEDs 1. Existing Facade: To be determined Co)) (X) 60w Power Supplies @ 0.85 amps each 2. 0.040"Aluminum letter returns painted to match black —�� Total Amps: X.XX 3. 1"Jewelite trimcap (Black) bonded to face and #8 pan head screws to returns i i 0 (1) 20 amp 120V Circuit Req. 4. 0.063" aluminum backs fastened to returns. Seal w/VOC compliant 360 white �' . ' w 1 _ ® LISTED ._____.. latex caulk to prevent moisture penetration. (interior of sign can painted white �1 i for maximum illumination) © I .-- i General Notes: 5. GE Tetra Powermax LEDs (White) ' . I I ' --{-- 6. 3/16" acrylic faces; #2447 White Acrylic for"ME" letters, #2016 Yellow acrylic for i i 14 This sign is to be installed in accordance with "Swoosh" w/ 3m #7725-12 Gloss Black vinyl 'drop shadow' on swoosh 0 - the requirements of Article 600 of the National 7. Disconnect switch UL Outdoor rated toggle type w/ neoprene boot per NEC 600-6 r i Electrical Code. 8. Primary electrical feed in UL conduit/customer supplied UL junction box L i • 9. Power Supplies , i I 0. 1) Grounded and bonded per NEC 600.7/NEC 250 10. 0.080"Aluminum raceway painted blackI j i O O 2) Existing branch circuit in compliance with 11. 2"Aluminum mounting clips, Maximum 6"from each end and every 48" o.c. (TYP) 1/4 Drain holes at I I NEC 600.5, not to exceed 20 amps 12. Rivets, 3/16" aluminum #66 w/ 1/4"0 thru bolt & hardware (letter to raceway fastening) bottom of letter cans I 1i 3) Sign is to be UL listed per NEC 600.3 13. Mounting hardware to suit (2) per letter 4) UL disconnect switch per NEC 600.6- required per 14. 0.080" Backer panel painted to match Black sign component before leaving manufacturer* *For multiple signs, a disconnect is permitted but Section @ LED Channel Letter not required for each section Raceway (Center) Scale: N.T.S. 5 Thisrende R1 10/14/16 EH Removed is for the awnings a :; _ - - the party for which @.as Mattress Firm Project D 110971 Z p R2 10/15/16 EH Added awnings back ilimia)( Itlsanunpublished original drawing not tobe Tigard South Project Mgr: Denise Childers R3 11/18/16 MD Added directional. changed awningcolor&pylon color dbu ed.reproduced,or exhibited without the • 9 1 g g consent of Apex Sign Group.Please contact, 6650 SW Bonita Road Designer: Kirk Forster w R4 11/21/16 EH Removed awnings ac unt manager for questions regarding this 9 SIGN G R o u Papexsigngroup.com Tigard, OR 97224 Created on: 10/13/2016 —_