Plans (92) e.,2_0/(,,-6)0,a . , ./1/0 Wcie.s_ . % ILLUMINATION PLAN LEGEND AND DETAILS 5 chats GENERAL NOTES LEGEND 1.ALL MATERIAL AND WORKMANSHIP SHALL CONFORM TO P.G.E.SCHEDULE 95 OPTION•C' Install aluminum davit-style light pole with LED luminaire on new LIGHT POLE LOCATION TABLE SPECIFICATIONS(OWNED BY WASHINGTON COUNTY)EXCEPT AS SHOWN OTHERWISE. LP pre-cast foundation.See Lighting Notes.Install in-line fuse disconnect POLE SCROLLS LUMINAIRE MOUNTING ARM o i ALL MATERIALS AND INSTALLATION SHALL BE APPROVED BY P.G.E. in each pole per detail this sheet. NO. FERRY RD OFFSET POLE LIGHT HEIGHT LENGTH FOUNDATION ill ® STATION LAMP NOTES _ STYLE DIST. ) m) TYPE' \./A 2.ALL ELECTRICAL EQUIPMENT SHALL CONFORM TO THE CURRENT STANDARDS Light pole number(N).See details in Light Pole Location Table. 1(EX) 1035.41.9 47.1'LT SIGNAL(EX) 120 LED 40'(EX) 15'(EX) N/A REPLACE LUMINAIRE ON SIGNAL POLE 01 RIEs OF THE NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION(NEMA)AND THE UNDERWRITERS LABORATORIES,INC.(U.L.).WHEREVER APPLICABLE. IN ® Install new LED luminaire on existing pole.See lighting notes and 2(EX) 1035+86.9 672'RT SIGNAL(EX) 120 LED 40'(E)() 15'(EX) N/A REPLACE LUMINAIRE ON SIGNAL POLE 0z ADDITION TO THE REQUIREMENTS OF THE PLANS.STANDARD SPECIFICATIONS, light pole location table. 3 1037+64.5 45.8'RT DAVIT 35' b' PRECAST NEW POLE 8 LUMINAIRE w w AND THE SPECIAL PROVISIONS,ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE CURRENT REQUIREMENTS OF THE NATIONAL ELECTRICAL Install 13"x 24"x 18"(Mn.Dimensions)PGE approved precast 4 1096+96.5 44.8'RT DAVIT 35' 8' PRE-CAST NEW POLE a LUMINAIRE +.r- CODE(NEC)THE NATIONAL ELECTRICAL SAFETY CODE,STANDARDS OF THE 1 A concrete junction box with concrete apron. 5 1040+40.6 61.5'Rr DAVIT 35' iAMERICAN NATIONAL STANDARDS INSTITUTE(ANSI),AND ANY LOCAL (Mn. ' PRECAST NEW POLE 8 LUMINAIRE m Install 17'x30"x 18" in.Dimensions)PGE approved precast 6 1041+51.9 619'RT DAVIT 80 LED TYPE III 36' 8' PRE-CAST NEW POLE&LUMINAIRE ORDINANCES WHICH MAY APPLY. MY concrete junction box with concrete apron. 7 1043+62 41.1'RT DAVIT 35' e' PRECAST NEW POLE E.LUMINAIRE 3.LOCATION OF ILLUMINATION CONDUITS AND JUNCTION BOXES ARE O Install(S=size)inch PVC Schedule 40 electrical conduit. a 1044.459 41.0 RT DAVIT 3s 8' PRECAST NEW POLE&LUMINAIRE APPROXIMATE.CONTRACTOR SHALL COORDINATE WITH OTHER UTILITIES 9 1045.86.4 40.9'RT DAVIT 35' 8' PRE-CAST NEW POLE 8 LUMINAIRE TO ENSURE PROPER INSTALLATION. . Install 3"conduit and wire as required by P.G.E. 10(EX) 1047.39.0 45.6'RT UTILITY(Ex) 35'(EX) 8'(Ex) N/A REPLACE LUMINAIRE ON UMW POLE 4.THE CONTRACTOR SHALL COORDINATE WORK WITH JEFF STEIGLEDER OF PGE N=Number of TypeXHHW conductors 'SEE LIGHTING NOTES,THIS SHEET. AT 503 672-5462 TO COORDINATE ( ) CONNECTION OF POWER FOR THE LIGHTING SYSTEM. N X X=AWG wire size (EX)=EXISTING 5.BOND LUMINAIRES TO POLE GROUNDING TERMINAL. PL I InstallIpull po y line(500 lb.minimum strength). APPROVED STREET LIGHTING EQUIPMENT: 4 LP Retain and protect existing street light pole. LIGHT LEVEL SUMMARY TABLE ROADWAY SEGMENT OR ROADWAY OR Retain and protect existing junction box. INTERSECTION DESIGN LIGHTING RESULTS TARGET LIGHT LOSS CO JB 1. LIGHT POLES SHALL BE ANCHOR BASE,DAVIT STYLE,SPUN ALUMINUM,NATURAL INTERSECTION VALUES FACTOR ALUMINUM FINISH: CLASSIFICATION RX Remove existing luminaire and arm.To be removed with power SW SclwBs MANUFACTURER: CATALOG NUMBER: pole by others. Ferry Road/ AneriaVCollector Max:2.0 Light Level:1.5Ic Light Level:1.5 is VALMONT/LEXINGTON 3500-8610804 SW 135th Avenue Intersection Min:0.7 Uniformity 2.1:1 Uniformity 5 3:1 0• J LU HAPCO 41-231PGE UP Retain and protect existing utility pole. Max:1.5 Q PBX POLE(FLAGPOLE INC.) RTASM35AAD1832D SW S STA 10036+Ferry Road Segment Arterial Light Level:0.9 k Light Level:0.9 is 0 B5 w I- UNION METAL 920-8179-Y2 36+ 5 20 to STA 1047+25 Min:0.3 Uniformity 3.0:1 Uniformity 3:1 SP Retain and protect existing signal strain pole. 0 tt 2. ANCHOR POLE FOOTING FOR NEW ALUMINUM POLES SHALL BE PRE-CAST CONCRETE: 0Install photocontrol electronic relay. Z Q !1 MANUFACTURER: CATALOG NUMBER: ^ OUTILITY VAULT COMPANY 5CL-LB-PGE NC Q Install base mounted service cabinet 120/240 volt metered per ODOT Std.Dwg.TM485 for signal and street lighting.See cabinet < 3. JUNCTION BOXES SHALL BE PGE APPROVED SPLICE BOXES. PGE APPROVED BOXES ARE: wiring diagram below for details. Ct Z MANUFACTURER: CATALOG NUMBER: EC Electrical conduit.See Traffic Signal Plans for details. Ww 13'x 24'x 18" 17"x 30'x 18' W w ct NEWBASIS FCA132418T-00043 FCA173018T-90026 Luminaire Pole Z ARMORCAST A6001946TAX18-PGE A6001640TAX18-PGE Hand Hole In-Line Watertight J LLJ HIGHLINE CHA132418HE1 CHA173018HEI - Breakaway Fuse Holder: ~ QUAZITE(HUBBELL) A42132418A017 A42173018A017 ' Ba Part No.LEC-JS and z � < o OLDCASTLE/CARSON INDUSTRIES 13241617 17301620 i .�- 8 I "Slow-Blow'Class CC WA Fuse: < Cooper Bussmann Pan No.FN0-R-10 d 0 'WASH CO LIGHTS"SHALL BE IN THE LID MARKING AREA. a Concrete grout pad w rn ROAD I "diameter pole drain _Z O Z 4. LUMINAIRE SHALL BE TYPE III LIGHTING PATTERN * - �III� 4r_ur-. MANUFACTURER: CATALOG NUMBER: BUG RATING: O n Varies 2 = J R Center in planter strip m J LEOTEK GREEN COBRA (80 LED) GC1-80E-MV-NW-3-GY-530-PCR7-WL 113-UO-G3 1 COBRA STYLE Q (120 LED) GC2-120E-MV-NW-3-GY-530-PCR7-WL B3-UO-G3 J '�� (7 LED LUMINAIRE _ CO^/� = h- 5. THE PHOTOELECTRIC CONTROL SHALL BE: ELMOOO .Light Pole I U • IN-LINE FUSE DISCONNECT MANUFACTURER: CATALOG NUMBER: • I NOT TO SCALE SELC 8483 - , - \ I 8 *O r ...mak. 6. 410 AWG,600 VOLT,3-CONDUCTOR,CLASS B STRANDING,TYPE TC,WITH - �� SUNLIGHT-RESISTANT 45-MIL PVC JACKET.SUITABLE FOR DIRECT BURIAL - A`1 • 120/190 Volt INSTALLATIONS. INSULATION TO BE BLACK,RED,AND GREEN PER NEMA WC-7 FOR NEC Sin�eO/rare XIX APPLICATIONS(TFN,THWN,THHN),WITH FILLERS OR BINDING TAPE ADDED TO PRODUCE I *See plans for wiring Soiree ROUND OUTER JACKET,RATED 90 DEGREE C DRY AND 75 DEGREE C WET,1000 FT NR eil. REELS.JACKET TO DISPLAY SEQUENTIAL FOOTAGE MARKINGS.2 REEL LABELS,ONE TYPICAL STREET LIGHT INSTALLATION u) a-, Circuit Breaker € ATTACHED TO THE OUTSIDE FLANGE SURFACE,ONE ATTACHED TO THE DRUM a F (15 A,277 V,1-O) WRAPPING:EACH TO DETAIL TOTAL FOOTAGE,INSIDE OR STARTING FOOTAGE. (PLANTER STRIP) Main Breaker �� s NOT TO SCALE (1004 4B0 V.2-P) rid Test Switch �� • (15A,277 V,1-V) 19 g To Photoelectric Control IVY LiahfiigContacfor I x z , (3-Ab.12AWS) .-,,•. "mYU� (3300 A,With 120VCoil) LO <, X r , r Metal Pole Grounding required Bonding Polymer cover *O o m i �� I q To Roadway?//urnrnafion on Signal Poles w only at the J xes located near lug Stainless steel or brass'L'bolts rn n ROAD Inky c W i illumination poles and nuts in diagonal corners. i • CircuiN1--rT.-�1 _ ,.� (30Ai4BO V Breaker-v) -� S1EQED NROff Vanes 1I7,1'* IO No.6 1,t I - in W r..,E't r 1'rigid PVC conduit ! wiHe Light Pole (YP) I111 and#6 ground wire N r Lgphhtng Contactor Cl) �e�„ 5/8"x8'ground rod and No.6 ���JI�r' I '� '0 ® Jj 130A,WlM 120VCoi!) Q copper ground wire shall be installed% ! � Rigid PVC !f+G I / _in the concrete junction box riser conduit(typJ ©ti:1O ,tee. To Street L' ti Circuit Al a EXPIRES:1v31rmn �� Rigid , I (60A,177 V,1-P) ` 1 3/4"-0'pea gravel " fiberglass NOT TO SCALE ! conduit bends 4)r Circuit Breaker r on1E i ovvmis I To Controller Cabinet _ I a * I INN (30A,480 V,2-O) O DRAWN 1 ACJ DESIGNED ice 1 CONCRETE JUNCTION BOX INSTALLATION(NEAR ILLUM.POLE) _ CO CHECKED I ea No Scale ti A PROJECT* I 2150951 NOTE I *See plans for wiring SERVICE CABINET WIRING ROADWAY sumTIT E 1. See Plans for circuit wires. ILLUMINATION LEGEND s o 2. Illumination Circuits shall be spliced according to Section 0292025 TYPICAL STREET LIGHT INSTALLATION WITH 240 VOLT ILLUMINATION TYPICAL STREET-LIGHT m saiNUMBER 3. Polymer concrete junction box cover,it used,is not required to be bonded.4. BMCL POLE DETAIL Q' Metallic conduit,if used shall be on all conduit endbonded in j unction boxes and in street light poles.wires. 5. Installand circuit (BEHIND SIDEWALK) NOT TO SCALE WI Ll.O E if a' VNDUSE! so2a1s40031 • FIRE PREEMPTION OPERATION SIGNAL AND DETECTION MODIFICATION PLAN ,;. SW SCROLLS FERRY ROAD AT SW 135TH AVE : pmPH6 PH5 Nt-... W%' —0. ri— / / 1 E El m O m �� <e fp EX.R/W illl i i CHANNEL A CHANNEL B CHANNEL C 4 ,/ z"d / o 13A iia(1) / /,` NORMAL PHASE ROTATION ©`� ENni"") Co L _. /- I / Ike Y P� lF : PED6 f �,g a / L 1 `• �� ®() N(1) 7 i 651 .;--,. --______ _ _ _ 7 iii [33' MII___7_ .W PHASES1&5 PHASES2&6 PHASE4 /r /ii_ - - = -- . -.-- ---- -- ------ ----- - 4 . . • , , .• 15 '"' air J-1 c L la1 s. ar F// 103s.o0 io3a oo 0 W _ r , ,r. e- 1-.. ..1037,00_ 5 G1 36+00 -. ... _ _ __.-- .. ,: _--___.- � --_..._. tit— ., ��� SW SCROLLS FERRY ROAD Q. g_..., _,.6 e ,.., at fa "` WI-°Z, /SI 1/F '-©!" / 'w-' .4. .., j - - rM Er 7 /z Wf -- 0 X2.5) in vf-tsy — m Al Z' �vat% p�----�- 1111- ------- UJ h- r '- _ ______ _ .____ ,aA- , ' `.' :Min. gregire'l*/,'" !in f ; m i�. C9fi1�` Q Q J 0 1a.] © \ 0 /'• i�;/ 4 SEE INSET"A' ` , O Is IA V / Q al m (/) U) 2 1- / Iv t 1.0 ' � , i at . ® vW m — LOOP DETECTOR WIRING DIAGRAM Q• / ' / "i' © �� 'Distance'is from Stop Line to center of loop or video detection zone in feet / �� � i ®♦0 O Loop/Zone Distance Phase Slot Pin / �� 117 (2)© y` ® !� O Number (Feet) ^ / Y � 0 2 EX IS 2 @U _C1-39 • / % N O op: Video EX.R/W CO �- W' Camera a EX 2 12L C7-43 ©Q OO 5 IIIS 5 J1U —C1-55 i s — J9U —C1-59 V m /S] m ®� , �` N , 8 EX 4 J6U —C1-42 Q / _pi: �� o r" 9 EX IZl1T,'] � �' A PROP.RNV 1. 10 EX I S 4 — J6L —C1-46 PROP.P.U.E. VYVY� / :: �� (2) LO I ,1 EX I S 6 — J2U C7-0o CONSTRUCTION NOTES: m ( LO 1 " PROP.F2/VV OO BOO ���III O©O W 13 Ex Match existing interconnect conduit size. /• 14 EX I S 6 J2L —C1-g4 EX.RNV 000 116411111 DO —1 '�F 15 DL 6 J3U C1-C4 0 Pull existing interconnect cable back to nearest © , / LL �1� ,NE��/ s is Ex t — liu —c13s junction box upstream and reinstall to cabinet through �„�� ��,2s) � �` �3.Lll mQ1mm •.a. LU , d 17 Ex new communications junction box. 13y nip r /�� (n 1 `i 16 EX IS 1 — f9U —01-60 © e`' r.ri Q OREGON 19 73 4 I6L —C7-45 ® Pull loop feeder cables back to nearest junction box �I ��` 13y�3y 0 g 20 75 4 lsu —a-41 upstream and reinstall to cabinet as shown. � -_.' � '� �+6��ft��0 •9y •�`Ey e� zt 15 /t� �� '� �' ' ` 'Y2��`t71I7©0 O Q ocs:12/31/2017 22 5 I s 4 18U —C1-49 ® Contact Kevin Ellington with Washington County at ®� ®dy t 23 5 4 f7L —C1-78 ® (503)846-7959 for access into the traffic signal cabinet. at �,' �'M Om47lmmm®0 I- €€ 5 IS a — nu —ct ss Install si nal and illumination conduct and whin in onem , iii‘D H oa,E 07MN,625 g g I ss JB/3 and detector and interconnect conduit and wirings yin the other JB/3. * mCEaaEm i WEEx=E%IS11ng �riOrliroper CI¢CKEO I WES S=Series Cabinet 0©00p PROJECTI i zisossro > © Connect to existing 1'conduit stub into cabinet.A,- NOTE: ©m SHEET TOLE 5 s Contractor is responsible for re-wiring and ® Connect to existing 2°conduit stub into Cabinet. 1E7© INSET'A" O� H SIGNAL&.DETECTION PLAN - re-numbering of new and existing detector ® Remove 246 conductors for signal power after new scale 1'=a' SCALE 2 SHEET NUMBER r loops 8 loop feeders,in junction boxes signal power conduit and conductors have been C 1 and cabinet,to match wiring diagram. intalleto cabinet from new BMCL. 0 20 40 /W^ TS 1. 1 LL LAND USES S0R20I5.00334