Loading...
Report .r?it .zofC- --0o 75-Z)�/1 ilk L!U W (hC 11 Gas Furnaces RUUD R92P Series pannumiumer Ruud Achiever° Series Multi position Gas Furnaces If- R92P- Series 92% A.F.U.E.t Input Rates from 40 to 115 kBTU [11.72 to 33.71 kW] ItA.F.U.E.(Annual Fuel Utilization Efficiency)calculated in accordance with Department of Energy test procedures MI I • 92% residential gas furnace CSA certified • Blower Shelf design—serviceable in all furnace orientations • 4 way multi-poise design • Pre marked hoses—insures proper system drainage • PlusOne-r"Diagnostics 7-Segment LED all units • Vent with 2" or 3" PVC • PlusOne"Ignition System—DSI for reliability and longevity • Replaceable Collector box • PlusOne'"Water Management System with patented Blocked • Hemmed edges on cabinet and doors Drain Sensor • Quarter turn fasteners for tool less access • Heat exchanger is removable for improved serviceability. • Integrated control boards feature dip switches for easy system Aluminized steel primary and stainless steel secondary con- set up struction provide maximum corrosion resistance and thermal . Self priming condensate trap fatigue reliability. • Low profile"34 inch"cabinet ideal for space constrained installations. • RELY ON RUUD.TM FORM NO.G22-536 REV.3 Table of Contents R92P Series Standard&Optional Equipment 3 Physical Data&Specifications 4 Model Number Identification 5 Dimensional Data 6 Blower Performance Data 7 Accessories 8 Limited Warranty 9 • 2 RELY ON RUUD.TM Standard&Optional Equipment R92P Series REMOTE SENSOR DIRECT SPARK IGNITION& REMOTE SENSOR i PRIMARY AND SECONDARY HEAT EXCHANGER a \te. \t„ 3n %40444114440GAS VALVE AND MANIFOLD IN-SHOT BURNERS sip IR it ..e. ' Mil DRAFT INDUCER PRESSURE SWITCHES -_` , 1 I� - 8 1 # '' BLOCKED DRAIN SENSOR SF i CONTROL 1- ' ) BOARD STANDARD EQUIPMENTOPTIONAL EQUIPMENT Completely assembled and wired; blocked drain sensor,7 Side and bottom filter racks;return air cabinet for all sizes. segment LED and marked hoses; heat exchanger; primary: NOTE: Furnace is not listed for use with fuels other than natural aluminized steel,secondary:29-4C stainless steel; induced or L.P. (propane)gas. draft; pressure switches; redundant main gas control; blower All models can be converted by a qualified distributor or local compartment door safety switch;solid state time on/off service dealer to use L.P.(propane)gas without changing burn- blower control; limit controls; manual shut-off valve; 100% ers. Factory approved kits must be used to convert from safety lock out;cool fan off delay;field selectable heat fan off natural to L.P.(propane)gas and may be ordered as optional delay; one hour automatic retry; power and self-test diagnos- accessories from a parts distributor. tics;flame sense current diagnostics;electronic air cleaner connections;twinning(built-in)features; humidifier connec For L.P.(propane)operation, refer to Conversion Kit Index Form. tions;humidifier on/off delay; low speed continuous fan option; single speed option for heating and cooling applications; WARNING transformer;direct drive, multi-speed blower motor. (Please note:a thermostat is not included as standard equipment.) THIS FURNACE IS NOT APPROVED OR RECOMMENDED FOR USE IN MOBILE HOMES RELY ON RUUD.TM Physical Data &Specifications R92P Series Physical Data and Specifications—Upflow Models -2 U.S.and Canadian Models ` MODEL NUMBERS R92PA0401317MSA R92PA0601317MSA R92PA0701317MSA R92PA085121MSA R92PA1001521MSA R92PA1151524MSA HIGH FIRE INPUTBTU/HR[kW]CD 42,000[12.31] 56,000[16.41] 70,000[20.50] 84,000[24.61] 98,000[38.71] 112,000[32.82] HEATING CAPACITY BTU/HR[kW] 39,060[11.45] 52,080[15.26] 65,100[19.67] 78,120[22.89] 91,140[36.00] 104,160[30.52] HIGH ALTITUDE OUTPUT 10%DERATE[kW]OO 35,154[10.30] 46,872[13.74] 58,590[17.17] 70,308[26.60] 82,026[24.03] 93,744[27.47] BLOWER(DxW) 11x7 11x8 11x8 11x10 11x10 11x11 [mm] [279 x 178] [279 x 203] [279 x 203] [279 x 254] [279 x 254] [279 x 279] MOTOR H.P.[W]- 1/4[187]-4-PSC 1/2[373]-4-PSC 1/2[373]-4-PSC 3/4[559]-4-PSC 3/4[559]-4-PSC 3/4[559]-4-PSC TYPE MOTOR FULL LOAD AMPS 4.0 6.8 6.8 8.3 8.3 8.3 _ HEATING SPEED MED-HIGH MED-HIGH MED-HIGH MED-HIGH MED-HIGH MED-HIGH COOLING SPEED HIGH HIGH HIGH HIGH HIGH HIGH MINIMUM EXT.STATIC .18[.045] .20[.050] .23[.057] .28[.070] .28[.070] .28[.070] PRESSURE(IN.W.C.)[kPa] MAXIMUM EXT.STATIC 0.8[0.19] 0.8[0.19] 0.8[0.19] 0.8[0.19] 0.8[0.19] 0.8[0.19] PRESSURE(IN.W.C.)[kPa] HEATING CFM @.2"[.049 kPa] 1049[494] 1139[537] 1211 [571] 1704[804] 1748[825] 1750[825] W.C.E.S.P.[L/s] COOLING CFM©.5"[.124 kPa] 1121 [528] 1232[581] 1318[622] 1742[822] 1782[841] 1934[912] W.C.E.S.P.[L/s] TEMPERATURE RISE-HIGH FIRE 25-55 35-65 40-70 35-65 35-65 45-75 RANGE IN DEGREES°F[°C] [14-31] [19-36] [22-39] [19-36] [19-36] [25-42] APPROX.SHIPPING WEIGHT 123.5[56] 128[58] 132[60] 147.5[67] 152[69] 165[75] (LBS.)[kg] AFUE OO 92.00% 92.00% 92.00% 92.00% 92.00% 92.00% NOTES: All models are 115V,60HZ,1 phase Gas connection size for all models is 1/2"[13 mm]N.P.T. iU Installation instructions for high altitude derate. OO Canadian installations only. OO In accordance with D.O.E.test procedures. 'S=Standard Models NOTE:Standard model complies with California low nox requirements. [ ]Designates Metric Conversions 4 RELY ON RUUD.TM Model Number Identification R92P Series Model Number Identification R92 P A — 040 1 3 17 M S A Ruud Series Motor- Design Series Input Stage-Single Airflow Cabinet Width Configuration- S=Standard Revision- 92% PSC A=1st Design BTU/HR 3-Up to 3 Tons 17=17.5" Multi-Position Marketing Efficient 040= 42,000[12.31 kW] 5-Up to 5 Tons 21 =21.0' (A-First Time 060= 56,000[16.41 kW] 24=24.5' Release) 070= 70,000[20.51 kW] 085= 84,000[24.62 kW] 100= 98,000[28.72 kW] 115=112,000[32.82 kW] [ ]Designates Metric Conversions • RELY ON RUUD.TM 5 Dimensional Data R92P Series FRONT BOTTOM TOP I A 121/32" 15/6" [42 mm]ONAL �[ r[41 mm] B B OPTI , VENT IOUTLET , 5/16^ OPTIONAL 1 A KNOCKOUT 5/a" 5/8" a COMBUSTION AIR I. [8 mm] P INLET KNOCKOUT [16 mm] [16 mm] e' .. _._ SUPPLY AIR O r Y 1927/32" A 247/a" [504 mm] ARI [631 mm] 261/4" F [667 mm] 24" 237/32" w [633 mm] R AIRRN 1925/32" [590 mm] [502 mm] N 1 / 34" -- — [864 mm] -- -- _ B/32" 0 [17 mm] O 1 V 13/4" -1. � I 121/32" C ~[45 mm] [{ [42 mm] I li O 1 i a A-a. a 263/16"[665 mm] ► .-263/16^[656 mm] ►I 41 295/8"[752 mm] I. X257/16"[646 mm] 281/16"[713 mm] ► 4 235/16"[593 mm] I OPTIONAL CONDENSATE OPTIONAL .1-11/B" 1927/32"[504 mm]-* s/a" 225/16"[567 mm] DRAIN(DOWNFLOW) CONDENSATE DRAIN [28 mm] f[16 mm] V - -- • ♦ i (DOWNFLOVV) OPTIONAL TRAP '�' j 2231/32"la LOCATION ° V� I - II [583 mm] • (HORIZONTAL) �� Of S CNAL GAS CONNECTION GAS I 327/e" "*---.... TRAP LOCATION CONNECTION jp gi [835 mm] - (HORIZONTAL) L OPTIONAL TRAP 291/15" 2313/16" ► OPTIONAL COMBUSTION LOCATION 291/32"• mm] VENT LOCATION [738 mm] [605n A (HORIZONTAL) [738 mm] • O . • OPTIONAL CONDENSATE •�.J y 1 O • DRAIN(UPFLOW) aPTIONAL VENT ///�Pf 261/8" r °• 1 II- AIR INLET 171/2" [583 mm] 177/16" [445 mm] [443 mm] CONDENSATE DRAIN `e _ OPTIONAL LOW VOLTAGE 263/16" 1 WIRING NPFLOM) • 181/6" 322/32" [665 mm] 14" ELECTRICAL CONNECTION • I [461 mm] [829 mm] �0.-____.,.,. ° [356mm] LINE VOLTAGE I OPTIONAL LINE VOLTAGE WIRING ELECTRICAL CONNECTION L LOW VOLTAGE J . V V V V V V V C V 225/8"[575 mm] Ai--23"[584 mml ► 243/16"[614 mm] it 8" 111/32" 11" 8" 265/16"[668 mm] > [203 mm] [280 mm] [279 mm] [203 mm] RIGHT SIDE LEFT SIDE UNIT DIMENSIONS (CLEARANCE TO COMBUSTIBLES) MINIMUM CLEARANCE(IN.)[mm] FLANGE DIMENSIONS MODEL LEFT RIGHT SHIP WGTS. R92P SIDE SIDE BACK TOP FRONT VENT (LBS•)[kg] A B C 040 0 0 0 1 [25] 2[51] 0 123.5[56] 171/2[445] 1617/64[413] 1613/64[412] 060 0 0 0 1 [25] 2[51] . 0 128 [58] 171/2[445] 1617/64[413] 1613/64[412] 070 0 0 0 1 [25] 2[51] 0 132 [60] 171/2[445] 1617/64[413] 1613/64[412] 085 _ 0 0 0 1 [25] 2[51] 0 147.5[67] 21 [533] 1949/64[502] 1945/64[500] _ 100 0 0 0 1 [25] 2[51] 0 152 [69] 21 [533] 1949/64[502] 1945/64[500] , 115 0 0 0 1 [25] 2[51] 0 165 [75] 241/2[662] 2317/64[591] 2313/64[589] 'A service clearance of at least 24"is recommended in front of all furnaces [ ]Designates Metric Conversions Supply and return depicted as upflow configuration. Flange configuration will vary depending on installation orientation. 6 RELY ON RUUD•TM Blower Performance Data R92P Series BLOWER MOTOR CFM [L/s]AIR DELIVERY MODEL SIZE H.P. BLOWER EXTERNAL STATIC PRESSURE INCHES WATER COLUMN[kPa] [mm] [W] SPEED 0.1 [.021 0.2[.05] 0.3[.07] 0.4[.10] 0.5[.12] 0.6[.15] 0.7[.17] 0.8[.19] LOW 732 [345] 695[328] 669[316] 639[301] 605[285] 547[258] 512[242] 487[230] R92PA 11 x 7 1/4 MED-LO 875 [413] 845[399] 820[387] 792[374] 766[361] 726[342] 659[311] 605[286] 0401317 [279 x 178] [187] MED-HI* 1073 [506] 1049[495] 1004[474] 975[460] 943[445] 900[425] 864[408] 798[376] HIGH 1279 [603] 1239[584] 1213[572] 1174[554] 1121 [529] 1069[504] 1033[487] 980[462] LOW 830 [392] 793[374] 755[356] 705[333] 654[308] 599[283] 544[257] 496[234] R92PA 11 x 8 1/2 MED-LO 940 [443] 908[428] 875[413] 821 [387] 766[361] 710[333] 653[308] 584[275] 0601317 [279 x 203] [373] MED-HI* 1168 [551] 1139[537] 1109[523] 1060[500] 1010[476] 942[444] 874[412] 802[378] HIGH 1421 [670] 1385[653] 1349[636] 1291 [609] 1232[581] 1147[541] 1062[501] 976[460] LOW 852 [402] 827[390] 802[378] 752[355] 701 [331] 662[312] 623[294] 580[274] R92PA 11 x 8 1/2 MED-LO 986 [465] 955[450] 923[435] 883[417] 843[398] 790[373] 737[348] 686[324] 0701317 [279 x 203] [373] MED-HI* 1238 [584] 1211 [571] 1183[558] 1139[537] 1094[516] 1036[489] 978[461] 897[423] HIGH 1493 [704] 1452[685] 1410[665] 1364[643] 1318[622] 1257[593] 1195[564] 1084[511] LOW 1313 [619] 1275[601] 1236[583] 1221 [576] 1184[558] 1141 [538] 1098[518] 1053[497] R92PA 11 x 10 3/4 MED-LO 1488 [702] 1452[685] 1415[667] 1384[653] 1328[626] 1279[603] 1229[580] 1170[552] 0851521 [279 x 254] [559] MED-HI* 1732 [817] 1704[804] 1676[791] 1630[769] 1579[745] 1498[707] 1417[668] 1343[633] HIGH 1983 [935] 1929[910] 1874[884] 1810[854] 1742[822] 1663[784] 1583[747] 1477[697] LOW 1329 [627] 1313[619] 1296 611] 1260[594] 1224[577] 1171 [552] 1117[527] 1049[495] R92PA 11 x 10 3/4 MED-LO 1535 [724] 1498[707] 1461 [689] 1422[671] 1382[652] 1325[625] 1268[598] 1203[567] 1001521 [279 x 254] [559] MED-HI* 1796 [847] 1748[825] 1700[802] 1656[781] 1612[760] 1536[725] 1460[689] 1370[646] HIGH 2019 [952] 1961 [925] 1903[898] 1843[869] 1782[841] 1687[796] 1592[751] 1489[702] LOW 1249 [589] 1234[582] 1219[575] 1183[558] 1146[541] 1112[525] 1078[508] 1017[480] R92PA 11 x 11 3/4 MED-LO 1440 [679] 1429[674] 1417[668] 1381 [651] 1344[634] 1313[619] 1281 [604] 1221 [576] 1151524 [279 x 279] [559] MED-HI* 1770 [835] 1750[825] 1730[816] 1696[800] 1662[784] 1611 [760] 1559[735] 1463[690] HIGH 2123[1001] 2077[980] 2031 [958] 1983[935] 1934[912] 1856[875] 1777[838] 1665[785] *Factory setting for heat all grey cells are valid heating settings.Do not use speed tabs and/or static pressure which do not fall into the grey cells on this table. NOTE:Unit tested without filters. [ ]Designates Metric Conversions • RELY ON RUUD.TM 7 Accessories R92P Series VENT TERMINATION KITS: = FOR HIGH ALTITUDES: RXGY-E02:Vertical/Horizontal Concentric Vent Termination Kit NOTE:For Canadian installations only,an optional Berate(manifold 2" Pipe(US Only) gas pressure reduction)method may be used to adjust the furnace for altitude.See Installation Instructions for more RXGY-E02A:Vertical/Horizontal Concentric Vent Termination Kit information.This optional method may NOT be used for U.S. 2" Pipe(US&Canadian) installations.See installation instructions as appropriate orifice RXGY-E03:Vertical/Horizontal Concentric Vent Termination Kit change is required. 3" Pipe(US Only) RXGY-E03A:Vertical/Horizontal Concentric Vent Termination Kit L.P.CONVERSION KIT:RXGJ-FP33 3" Pipe(US&Canadian) CONDENSATE PUMP KIT:PROSTOCK&1 PCB151 TUL RXGY G02:Direct Vent Furnace Side Wall Vent 2"or 3" (US Only) DOWNFLOW/HORIZONTAL CONVERSION KIT:RXGY-CK RXGY-D05:Combustion Air Drain Kit 2" DOWNFLOW/HORIZONTAL LEFT ZERO CLEARANCE CONVERSION KIT:RXGY-ZK RXGY-D06:Combustion Air Drain Kit 3" COMBUSTIBLE FLOOR BASE:RXGC-B17 NEUTRALIZER KIT:RXGY-A01 RXGC-B21 (Replacement Cartridge 54-22120-01) RXGC-B24 EXTERNAL BOTTOM FILTER(UPFLOW/HORIZONTAL)RACK: RXGF-CB [ ]Designates Metric Conversions EXTERNAL SIDE(UPFLOW)FILTER RACK:RXGF-CD EXTERNAL(DOWNFLOW)FILTER RACK:RXGF-CC FILTER RACK FILTER SIZES*INCHES[mm] RXGF CB RXGF-CD RXGF-CC MODEL (UPFLOW/ (UPFLOW) (DOWNFLOW) HORIZONTAL) R92PA040 153/4 x 25 153/4 x 25 14 x 20 [400 x 635] [400 x 635] [356 x 508] R92PA060 153/4 x 25 153/4 x 25 14 x 20 [400 x 635] [400 x 635] [356 x 508] R92PA070 153/4 x 25 153/4 x 25 14 x 20 [400 x 635] [400 x 635] [356 x 508] R92PA085 191/4 x 25 153/4 x 25 14 x 20 [489 x 635] [400 x 635] [356 x 508] R92PA100 191/4 x 25 153/4 x 25 14 x 20 [489 x 635] [400 x 635] [356 x 508] R92PA115 223/4 x 25 153/4 x 25 14 x 20 [578 x 635] [400 x 635] [356 x 508] INDOOR COIL CASINGS MODEL NUMBER RXBC-D17A1 RXBC-D21A1 RXBC-D21B1 RXBC-D24A1 8 RELY ON RuuD.TM / / ..i ., /-,-.:-:_. - ,. - / .,.. .: .44,2, '''."Sky'N.'°-..4,eiw .../.1'°/..;... , ../i . a ' J Gogle Earth G200 gIe Earthfeet. 200 A 0meters 60