Plans PERMIT ADDRESS CLOSED MST2012-00299 11062 SW MALLOW TER 9/9/2013 MSl`2012 00300 11066 SW MALLOW TER 9/6/2013 • MST2012 00301 11070 SW MALLOW TER 9/9/2013 MST2012 00302 11084 SW MALLOW TER 9/9/2013 THIS TRUSS ADJUSETED BACK 2"FOR PLUMBING/TOLIET MST2012 00303 11086 SW MALLOW TER 9/9/2013 2 REQUIREMENTS 88-0-0 1 20-0-0 16-0-0 16-0-0 16-0-0 20-0-0 1 Ir UNIT AM UNIT CUNIT UNIT UNIT A LOT 69 9 LOT70 1 1LOT7 LOT 72 1 LOT 73 FRAMING BY FRAMING BY FRAMING =Y OTHERS HERE OTHERS HERE OTHERS H- -E FRAMINGHBY OTHERS HERE 0 5-1/8"X 22"GLB UP FRAMING BY 5-1/8"X 22"GLB UP °° TRUSSES STUBBED OTHERS HERE TRUSSES STUBBED TRUSSES LOADED FOR 5-1/8"INTO FACE OF 5-1/8"INTO FACE OF WET SPRINKLER SYSTEM 1 BEAM 1.1/4"X 14"RIM BOARD HERE-NO TRUSS 1-1/4"X 14"RIM BOARD HERE-NO TRUSS 1-1/4"X 14"RIM BOARD HERE-NO TR `- BEAM REQUIREMENTS USE HU-46 n HU-a6 74-Z-67 3\ 15-8-8 15-8-8 15-8-8 A FEW NOTES ON THE LAYOUT,.. ) o Cl) ¢ n r� n A2 3 c 9 1. THE TYPE"C"LAYOUT HAS BEEN ADJUSTED . o — � I 0 U U co o TO START AT 2'-0"0/C AND GO FROM THE �o --TA-67---- q4 5� Z "C-DRAG"TOWARDS THE BACK OF BLDG.FOR PLUMBING/TOLIET LOACATION J _--- J O Wo o® v v I w 2. ON THE"UNIT-A'S"THE LAST TRUSS TYPE"A2" _ C DRAG 380 PLF DRAG C-DRAG 380PLFDRAG C DRAG 380 PLF DRAG = HAS BEEN SHIFTED OUTAPPROX.2"TO PROVIDE HU-46 C C } C o o MORE ROOM FOR TOLIET/PLUMBING REQ. 9 Q GO DOWN r. C C C GLB DOWN •:( 9 3. TRUSS TYPE'A4"-AT STAIRWELL-WILL BE c� AG-3 r- �-T O m o M o O 13/4"x 14" M i/ 1-3/4"x 14'RIM BUILT AT 4'-2-1/4"(50-1/4') PER REQUEST w COm HGf�S26 2 C7 CO M CG/ CG CG HGUS26-2 c° A "' 3-: o- HU-46 °2 4. TRUSSES ADJUSTED FOR 1-1/4"RIM AT g gg 3-s- EXTERIOR WALLS&PARTY WALLS 3-6-8 ¢ 19, 3-6- o CSI N , 3-6-8 k \ / op ° 5. TRUSSES ADJUSTED FOR 1-3/4"RIM AT T ^ o m 1 - IU - _ U co'l'N M sk r STAIRWELL LOCATIONS, 6. TRUSSES DESIGNED TO ACCOMODATE N �T< rI CG CG CG WET SPRINKLER SYSTEM 3-1/2"X 14"BEAM-UP' " C 3-1/2"X 14"BEAM-UPJ-� U$E hu4e cLSE IU-46 SPANS OF EACH OF THE GIRDERS: 0 3.1/2"X14"BEAM-UP I C-DRG2 j NO TRUSS HERE c CDRG-2 NO TRUSS HERE 3-1/2"X 14"BEAM-UP >? Ig i - N !IL N o TYPE "AG" 15=8-3/4" FRAMING BY OTHERS C9 N f 381 PL'DRG TYPE "AG-1" 8'-2" 12-0-0 8-0-0 e 6-0- 7-8-0 �I 5-7-8 10-4-8 6-0-0 10-0-0 tt 11 1I_ _ 8-0-0 12-0-0 PULTE HOMES 3-1/8"X GLB UP NO DUCT CHASES PROVIDE TYPE "AG 2" 3=8-1/2" TRUSSES STUB INTO BEAM IN FIRST FLOOR TRUSSES SUMMER CREEK BLDG-20 FIRST FLOOR USE HU-46 PROBUILD CLACKAMAS TRUSS TYPE "AG-3" 211-1/2" 15877 SE 98TH.AVE. LOT 69 THRU 73 CLACKAMAS, OR 97015 TYPE "CG" 15=8-1/2" y PROBUILD TRUSS JOB#J1203520 503-557-8404 503-557-8428(FAX) 88-0-8 19-11-8 15-11-0 15-11-8 15-11-0 19-11-8 1'-4-3/16"HEEL HERE 1=4-3/16"HEEL HERE REG. HEELS HERE REG. HEELS HERE REG. HEELS HERE F < >6 < > < CO3-A < < > < < ( ) CO2A(3) 1302A(7 >) A (i ) A03(5) B02(7) CO2(3� CO3(6) O - O �/12 q . c UNIt4M--LOT 6r . - PI UNIT ALLOT 73 UNIT C LO 7 0 UNIT S-LOT 71 UNIT C-LOT--7g 4 ' 5'x1(:' C o coi I PURN*CE• o .o' 5'x10 _ MI -10' 0 9 I N TRUSS j U FURNA - 5'X 10 0 -o .. o o 01 I 0 IN TRUSS 0 5'X 10' i FURNACE SPACE i o IN TRUSS ° co 0 M c FURNACE SPACE IN TRUSS "' ''' IN TRUSS ME x/12 HUS-26 HUS-26 • r 4 HUS-26 7-'1-8 D02 ► , o - o DOl 8/12 P2 D02 N ' 8/12 2-0-0 o r �. .. 411 8 --�`-` PI 512 ,I DO1 .r o `- 8/12 :.>tra���l ;c o r E02 \ vieo o P -�� W Z(5' 8�4 6 I \ ' 102(fi) L02 ' N 0 - 8/ 2 I ��..-.. _ , PGE XGE 0 _ate �1 E01 XGE-1 8-5-0 LO1 8-7-8 5-9-8 5-6-8 r 5-9-8 •- -: 11-4-0 6/12 12 0-0 10-11-8 ROOFS AT FIRST 6/12 FLOOR C 1-0-01 CENTEX HOMES Mil 5.w SUMMER CREEK TOWNHOMES BLDG-20 ROOF 7-8-0 1=4-7/16"HEELS HERE ROOFS AT FIRST EYEBROW ROOFS AT USE LUS-24 AT ALL FLOOR UNIT"C"TYPICAL 2-PLACES LOWER ROOFS AND PROVIDING 10 TOTAL AT EYEBROW ROOFS 200 PLF DRAG APPLIED TO MAIN UPPER GE TRUSSES 2X4 VENTS & BLOCKS ' PER PLAN SPECS PROVIDED AT TRUSS I' BALL UPPER ROOF COMMON TRUSSES HEELS-TYPICAL PROBUILD CLACKAMAS TRUSS DESIGNED FOR FURNACE PLATFORM LOADING AND FOR FIRE SPRINKLER REQUIREMENTS JOB#J1203522 • t. Z-0"0/C& GO FROM "A08"TOWARDS BACK 2'-0"0/C&GO FROM OF BUILDING "A08"TOWARDS BACK OF BUILDING 20-0-0 16-0-0 16-0-0 16-0-0 20-0-0 1 UNIT AM 7UNIT C UNIT B UNIT C 'UNIT A 1 LOT 69 LOT 70 LOT 71 LOT 72 SLOT 73 FRAMING BY FRAMING BY FRAMING BY FRAMING BY FRAMING BY OTHERS OTHERS OTHERS OTHERS OTHERS ,, 1-1/4"x 14"RIM HERE 1-1 "x 14"RIM HERE 1-1/4"x 14"RIM HERE 1-1/4' x 14"RIM HERE 1-1/4"x 14"RIM HERE 1 8-1-8 / r SPANS OF GIRDERS: u_ cob 15-8-8 15 = 8 1588 �' " TYPE "A01" 15'-8-1/2" DU TS CE E O R IT E •PPRO TOLIET DROP A- • -• DUET DROP APP OX TOLIET DROP D CTS CE TE 0 ER IT HE II 1=4"WIDE DUCT CHASE HERE (D 1=4 WIDE DUCT CHASE HERE TYPE "A02" 15=8-1/2" 0 0 ,.- 0 0o V U '� T N N I , < < < < A(5) ' TYPE "A03" 8'-5" A (5) Q Q Q Q 380 PLF DRAG I 38C PLF DRAG LIJ / —� C DRAG C DRAG I 2=0"O/C& GO w TYPE "A04" 3'-8-1/2" --> FROM OUTSIDE IN ¢ _ A08 11-10-0 A01-A A08 w a? ZFROM gUTSIDE IN 3-6-8 u, 14-10-3 _ TYPE "A06" 15-8-1/2" o op o OC 14-1 q 0 -I L 3-6-8 ,_ a - 3-61 >� Q Of M �e®oma =�__ a 4 =, HU-46(7) M oo> o o 113/4"X 14"RIM "' "' a HU-46 7 a 11 -0 1-3/4x14 Raw rr " 6 th TYPE "A08" 15=8-1/2" a 0 3-6-8 / W W W g J o k Q W W I m ^ 3 W N w Q TYPE "A01-A" 15-8-1/2" W m _ =c - 3 HGUS26-2 Hf US26-2 3 -c v Q '` pi , ^ t Q /// _. 1- 4 (/) o Fri v a A CO M 1'-113/4"WIDE DUC HASE-Il E ;:; - I.1 co- 7'3/4"WIDEDL)CTCHASENERE _co IF Q A04 A06 -4 0 ti A06 _ - ad O 4 • 1)A: 8 — - c� M o c�c, Q Q U 0 UNR 14"RIMHERE ro d 1-1/4•'x14 RI •ERE 1-1/4"x 14"'RIM HERa 1 I T 1-1/4"x 14"RIM HERE X00 LLH U-46 63A HU-46 DUCT CHASES ARE °° I 1 c PROVIDED IN THES: ci 12-0-0 8-0-0 7-1-8 7-8-0 N 5-0-. 11-0-0 7-1-8 7-8-0 — 8-0-. 1•-o-o FLOOR TRUSSES ligiiiNi CENTEX HOMES REGULAR FLOOR SUMMER CREEK TOWNHOMES TRUSS HERE-NO GIRDER ,BUILDING 20 UPPER FLOOR TRUSSE 4 1PROBUILD CLACKAMAS TRUSS ALL(21)OF THE TYPE"Cl" TRUSSES LOADED FOR JOB#J1203521 ARE ALL THE SAME TRUSS SPRINKLER SYSTEM REQUIREMTNS PER PREVIOUS REVIEWS t THESE HANGER INTO 1-3/4"X 14" BEAM UP