Plans (31) I/P4-s PROJECT NOTES: SYSTEM INFORMATION VICINITY MAP-SCALE: NTS MODULE NOTES: TABLE OF CONTENTS 1. 9880W DC, 7800W AC SOLAR PHOTOVOLTAIC SYSTEM. 1. REC SOLAR: REC260PE(BLK) DIMENSIONS: 2. (38) REC SOLAR: REC260PE(BLK) MODULES WITH (1) MAGNETIC TRUE -4 65.55"x 39.02"x 1.5" PAGE POWER-ONE: PVI-4.2-OUTD-S-US-A(240V) INVERTER AND ARRAY PITCH ORIENTATION ORIENTATION DESCRIPTION z 2. PORTRAIT: CLAMP 8.2"-16.4"FROM EDGE # (1) POWER ONE: PVI 3.6 OUTD S US A(240V) INVERTER. a 3. LANDSCAPE: CLAMP 0"-9.8"FROM EDGE - 3. TWO STORY COMP SHINGLE ROOF AT 30° PITCH. AR-01 30° 164° 180° PV-01 SITE PLAN 11607SW 04 RACKING NOTES: 4. CONSTRUCTION FOREMAN TO CONFIRM FINAL CONDUIT M— U ai M . ,7 i% 1. SNAPNRACK SERIES 100 OR S100 UL LISTED; RUN PLACEMENT WITH CUSTOMER. FLUSH MOUNT L-FOOT. SEE PEN D01. PV-02 MECHANICAL 5. APN#: R0491505 8 o 2. RAFTER AND PENETRATION LOCATIONS TO BE 6. CONTACT: BOB ANNENBERG, (503) 805-4339 ' PV-03 ELECTRICAL 7. DESIGN CRITERIA: Z DETERMINED IN THE FIELD 7.1. SYSTEM WEIGHT: 3LBS/SQFT. 3. LAG SCREWS:5/16"TECEINIEDMENT _° \„/tG. S-1 STRUCTURAL DETAIL _a FEB 2 3 2015 40 CITY OF TIGARD BUII DING DIVISION SITE PLAN-SCALE=3/128"= 1'0" i t D1 -AR-01 -SCALE: 1/8"= 1'-0" (N) PV PRODUCTION METER (N) REC INSTALLED PV ��� / 35'-1" / %' / 26'-3" �-1" (EXTERIOR WALL) LOAD CENTER `� (E) MAIN PANEL (EXTERIOR WALL) r 1'-2" (INTERIOR WALL) (N) INVERTERS WITHv � o (E) SERVICE ENTRANCE INTEGRATED DC DISCONNECTS (EXTERIOR WALL) (EXTERIOR WALL) )' 22' /4'-5" '- PL --��- 6 MOUNTAIN ROAD PLN 97% s SW BULL PL 97% PL r1' • �� N. V\� t.A,A 26'-2" i a 96% 97% ............ .- 9 ....., a.... --... ...---- - 8'-9" - 4 A J d . , 97% a Ii 3 -* I - _ ----"- _ I C97% ITY OF TUMID a ItEViiIVEDFOR ©D COM' TA'l�t Allaroyeat f 1.4''' 4 1 1 46'-1" OM I . 4 1 SEE SHEET S-1 FOR # INDICATE E t 2r- 1-s- y+�C.,G/ 44 I ,. I PENETRATION LOCATIONS ##% AT MARKED �fi lltddres� : i +�tw `�` - D2 -ELEVATION DETAIL-SCALE: NTS Suite ft p 4 Ja kg ........► Dates '2. I e s %. IPOOMMINIMMONIMIONN.e 4 1-5" PL PL PL PL 31'-2" (N)CONDUIT RUN (IN ATTIC) (E) DRIVEWAY °° (E) PROPERTY LINE (N)ARRAY AR-01 (E) RESIDENCE ♦ - . OFFICE COPY REC .1REC SOLAR,INC. 3380SE20TH,PORTLAND,OR DESIGNER: ORCL#180a6a s7zoz KLEIN REC PROJECT NUMBER: ANNENBERG RESIDENCE SITE PLAN REV:A PHONE 503-766-4332 PV-01 SO �` FAX5o3205-0743 6797272993 DRAFTER: DI ANNENBERG (601R-430ANNE) 14680 SW 117TH PLACE, TIGARD, OR 97224 7/24/2014 (2) 5/16"-18 x 2-1/2" SS HCS (2) 5/16" SS SPLIT LOCK WASHER SNAPNRACK MODULE MID CLAMP RAIL SPLICE INSERT NOTES: ® • LAG BOLTS MUST EMBED IN ROOF SNAPNRACK MODULE END CLAMP So- STRUCTURAL MEMBERS/RAFTERS • TORQUE ALL 5/16" HARDWARE TO 10 FT-LBS SNAPNRACK CHANNEL NUT (120 IN-LBS) TORQUE ostr-- i RAIL SPLICE TOP • RAIL CAN MOUNT TO EITHER SIDE OF L-FOOT SNAPNRACK STANDARD RAIL // (UPSLOPE VS. DOWNSLOPE) �4` ___-_-.--;., -:::-.........0000004r. (2) 5/16" SS SPLIT • FOR UNEVEN ROOFS, USE 1" STANDOFF SHAFT �lo LOCK WASHER SNAPNRACK RAIL 5/16%18 x 1" SS HCS SPLICE ASSEMBLY SNAPNRACK FLASHED STEP 3: SECURE L-FOOT TO L-FOOT KIT STANDOFF BASE TO 5/16" SS SPLIT SECURE FLASHING AND LOCK WASHER 5/16"-18 x 3.5" SS HLS MOUNTING RAILS (MIN 2.5" EMBEDMENT TO STEP 2: SLIP FLASHING OVER SNAPNRACK L-FOOT RAFTERS) L-FOOT BASE 5/16"x 3/4" FLAT WASHER STEP 1: BOLT L-FOOT BASE TO SNAPNRACK CHANNEL NUT ROOF WITH LAG BOLT 5/16"-18 x 3/4" SS HCS SNAPNRACK STANDARD RAIL ' 5/16"-18 SS FLAT HEX NUT = _ �$7 ` 5/16" SS SPLIT LOCK WASHER SNAPNRACK L-FOOT BASE \ �, `� \ ROOF DECKING SEAL PENETRATION AND �1� E _ UNDER BASE WITH -Ak RAINBUSTER (OR \wih,. 4 EQUIVALENT) SEALANT /� (E) ROOF \ DECKING i� N Ili il SNAPNRACK COM OSITION EEO`NS1PL��xO FLASHING GOM' (E) RAFTER SNAPNRACK RACKING SYSTEM SERIES 100: L-FOOT MOUNTING DETAIL REC REC SOLAR,INC. 3380SE20TH,PORTLAND,OP DESIGNER: OR CL#180464 s720z KLEIN REC PROJECT NUMBER: ANNENBERG RESIDENCE REV:A PHONE 503-766-2-0 MECHANICAL PV-02 SD FAX 503-205-0748 6197272993 DRAFTER: DI ANNENBERG (601R-430ANNE) 14680 SW 117TH PLACE,TIGARD, OR 97224 7/24/2014 LINE DIAGRAM: I 120/240 VAC SYSTEM CHARACTERISTICS-INVERTER 1 SINGLE PHASE SERVICE PV MODULES POWER-ONE: SYSTEM SIZE 5200 W METER#: PVI-4.2-OUTD-S-US-A(240V) / REC SOLAR: REC260PE(BLK) • < © PGE IN23153664 4200 WATT INVERTER JUNCTION BOXI - *�// (10) MODULES SYSTEM OPEN CIRCUIT VOLTAGE 412 V UTILITY 0---e----0 �2 OR EQUIVALENT 1 (1)STRING OF (10) MODULES SYSTEM OPERATING VOLTAGE 307 V GRID - .../-, _ -w- MAX ALLOWABLE DC VOLTAGE 600 V b EXISTING o--��o . PV MODULES C320A MAIN SYSTEM OPERATING CURRENT 17 A 4 - / REC SOLAR: REC260PE(BLK) 1 BREAKER DUAL MPPT TRACKERS STRING * V/ (10) MODULES SYSTEM SHORT CIRCUIT CURRENT 22.53 A NEW 100A PV COMBINER& LOAD RATED DC `t' (1)STRING OF(10) MODULES LABEL PLACEMENT:AC BREAKER EXISTING LOAD CENTER DISCONNECT AND ACFI (INSIDE OR FRONT OF PANEL) < _ 400A MAIN *NO LOADS TO PV MODULES SYSTEM CHARACTERISTICS-INVERTER 2 PANEL DEDICATED PV BE INSTALLED* POWER-ONE: FACILITY KH METER PVI-3.6-OUTD-S-US-A(240V) REC SOLAR: REC260PE(BLK) KV VH - 3600 WATT INVERTER JUNCTION BOX - `¢�/ (9) MODULES- SYSTEM SIZE 4680 W d_4 r 43 2 OR EQUIVALENT 1 (1)STRING OF (9) MODULES SYSTEM OPEN CIRCUIT VOLTAGE 371 V -0 0- 0 .�` I -.--- SYSTEM OPERATING VOLTAGE 276.3 V e-e o I PV MODULES MAX ALLOWABLE DC VOLTAGE 600 V FACILITY GROUND 250V METER SOCKET 25A BREAKER(A) / REC SOLAR: REC260PE(BLK) SYSTEM OPERATING CURRENT 17 A 50A PV T BREAKER AT 125A CONTINUOUS& 20A BREAKER(B) DUAL MPPT TRACKERS STRING - *fiN// (9) MODULES OPPOSITE END 240V METER COMBINER&LOAD RATED DC `I' (1)STRING OF (9) MODULES SYSTEM SHORT CIRCUIT CURRENT 22.53 A OF BUSBAR 200A, FORM 2S DISCONNECT AND AFC! LABEL PLACEMENT:AC BREAKER (INSIDE OR FRONT OF PANEL) NOTES TO INSTALLER: CONDUIT SCHEDULE SIGNAGE: WARNING 1. 378 VDC EXPECTED OPEN CIRCUIT STRING VOLTAGE. 2. ADD 50 AMP PV BREAKER TO MAIN PANEL. WARNING-Dual Power Sources ELECTRIC SHOCK HAZARD # CONDUIT CONDUCTOR NEUTRAL GROUND Second source is photovoltaic system 3. FIT METER BASES SHOULD BE WIRED AS FOLLOWS: UTILITY SOURCE TO DO NOT TOUCH TERMINALS LABEL PLACEMENT:MAIN PANEL TERMINALS ON BOTH LINE AND TOP LUGS, PV SOURCE TO BOTTOM LUGS. 1 NONE (4) 10 AWG PV WIRE NONE (1)6 AWG BARE COPPER NEAR METER LOAD SIDES MAY BE ENERGIZED WARNING IN THE OPEN POSITION 2 3/4"EMT OR EQUIV. (4) 10 AWG PV WIRE NONE (1)6 AWG THHN/THWN-2NVERTEROUTPUTCONECTIONHIS OVERCURRENT DOE RELOCADC VOLTAGE IS ALWAYS PRESENT 3 3/4"EMT OR EQUIV. (2) 10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 LABEL PLACEMENT:AC DISCONNECT, WHEN SOLAR OODULES COMBINER BOX,INVERTER ARE EXPOSED TO SUNLIGHT 4 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 WARNING-Electric Shock Hazard LABEL PLACEMENT: (1)8 AWG THHN/THWN-2 No user serviceable parts insi st /� DC DISCONNECTS Contact authorized servicer for assistance LABEL PLACEMENT:AC DISCONNECT, WARNING COMBINER BOX,INVERTER Voltage Drop AC Voltage Drop DC ELECTRICAL NOTES: CAUTION:SOLAR ELECTRIC ELECTRIC SHOCK HAZARD Run Name Inverter to Main Panel Run Name Modules to Inverter SYSTEM CONNECTED IF A GROUND FAULT IS INDICATED 1. PHOTOVOLTAIC SYSTEM WILL LABEL PLACEMENT: NORMALLY GROUNDED CONDUCTORS COMPLY WITH 2011 NEC. Select Material Cu Select Material Cu CONDUIT,JUNCTION BOXES MAY BE UNGROUNDED AND ENERGIZED 2. ELECTRICAL SYSTEM GROUNDING Select Wire Size 8 Select Wire Size 10 PHOTOVOLTAIC POWER LABEL PLACEMENT: WILL COMPLY WITH 2011 NEC. SOURCE INVERTER 3. PHOTOVOLTAIC SYSTEM IS Select Conduit Type EMT Select Conduit Type EMT LABEL PLACEMENT: CONDUIT,JUNCTION BOXES WARNING UNGROUNDED. NO CONDUCTORS Select Voltage&Phase 240 1-phase Select Voltage&Phase DC ARE SOLIDLY GROUNDED IN THE DC Voltage(Use DC Voltage(Use string fiu[LLI[s;)Il -)> IKIL ,%1i', ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS INVERTER. SYSTEM COMPLIES string Vmp,otherwise Vmp,otherwise leave LABEL PLACEMENT: TERMINALS ON BOTH LINE AND leave blank for AC) blank for AC) 307 ALL DISCONNECTS LOAD SIDES MAY BE ENERGIZED WITH 690.35. MODULE CHARACTERISTICS Enter Distance to Load IN THE OPEN POSITION 4. MODULES CONFORM TO AND ARE (ft) 15 Enter Distance to Load(ft) 85 LABEL PLACEMENT: LISTED UNDER UL 1703. REC SOLAR: REC260PE(BLK) 260 W Enter Load(Amps) 17.19 Enter Load(Amps) 15 AC DISCONNECTS 5. INVERTER CONFORMS TO AND IS OPEN CIRCUIT VOLTAGE 37.8 V OUTPUTS OUTPUTS LISTED UNDER UL 1741. 6. ARRAY DC CONDUCTORS ARE OPEN CIRCUIT VOLTAGE: (690.7) 41.1 V Voltage Drop(Volts) 0.40 Voltage Drop(Volts) 1.99 SIZED FOR DERATED CURRENT. %Voltage Drop 0,17 a/o Voltage Drop 0.83 WARNING 9.01 AMPS MODULE SHORT MAX POWER VOLTAGE 30.7 V VARIABLES VARIABLES ELECTRIC SHOCK HAZARD CIRCUIT CURRENT. SHORT CIRCUIT CURRENT 9.01 A Phase Factor 2 Phase Factor 2 THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE 14.07 AMPS DERATED SHORT K 12.9 K 12.9 UNGROUNDED AND MAY BE ENERGIZED CIRCUIT CIRCUIT(690.8(a) &690.8 SHORT CIRCUIT CURRENT(690.8(A)(1)) 11.26 A Q-Factor 1 Q-Factor 1 (b)). Circular Mils 16510 Circular Mils 16510 LABEL PLACEMENT: JUNCTION BOXES,COMBINER BOXES, DISCONNECTS RE REC SOLAR,INC. 3380SE20TH,PORTLAND,OR KLEIN REC PROJECT NUMBER: ANNENBERG RESIDENCE REV:A E. OR CL 64 s�zoz DESIGNER: PHONE 503-766-4332 ELECTRICAL PV-03 SD �` FAX 503-205-0748 DRAFTER: DI ANNENBERG (601R-430ANNE) 14680 SW 117TH PLACE,TIGARD, OR 97224 7/24/2014 6197272993