Plans (23) ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A VE - AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. - BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN OCT 2 2x14 • EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. CITY�P•�•YCs1 � (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING - EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, REVIEWED FOR CODE COMPLIANCE CITY OFT[GAR FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE ANGDNISION GALV GALVANIZED HAZARDS PER ART. 690.17. pp 14 GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE OTC: I j GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY Permit#: ice( -20(n _0Q(e HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. t I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Address: i `76 Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Suite#: Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER (� .-7(t4-7 kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR By: Date: l kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC BUILDI LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY OFFICE COPY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE • OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE - ------4 PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING P01 POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL - STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT3R NEMA 3R, RAINTIGHT y " a " '„ .. ''3 le"' PV1 COVER SHEET ti „E_ Y , 4, PV2 SITE PLAN ` ` ''"''" ,;. PV3 STRUCTURAL VIEWS ' % - . .. - "i. `` ' ev .f " , ,. PV4 UPLIFT CALCULATIONS �q R. ':�-- ., �2, ." �, + PV5 THREE LINE DIAGRAM LICENSE GENERAL NOTES `a , F.. - —; .j� t._ PV6 ELECTRICAL CALCULATIONS 1. ALL WORK TO BE DONE TO THE 2010 OBC ` " • '' �� '"" '� .0 t-.. ...-° Cutsheets Attached OR # 180498 BASED ON THE 2009 IBC. = '* _"= - _ "� , , J RGC, CGC1 2. ALL ELECTRICAL WORK SHALL COMPLY WITH f � THE CURRENT NATIONAL ELECTRIC CODE AS v ` r AMENDED BY THE OREGON ELECTRICAL SPECIALTY � " ° . �' •`� • to ' CODE. a! —a�"i -"` s '�i ,`,�; .. _ MODULE GROUNDING METHOD: ZEP SOLAR , ' ,- , tET -- K AHJ: Tigard 'r4 f ' - '°' " at... :* .. .,• t, , .' REV BY DATE COMMENTS ��,m:„ �" * '-, �'., t REV AIMS DATE COMMENTS • - UTILITY: Portland General Electricilt0 0 ' ®®© e ro, .r and regon, of,Oregon, U.S. GecJ igal Survey© m . CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: JB-9722209 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: �\`!� CONTAINED SHALL NOT BE USED FOR THE SMITH, RICHARD SMITH RESIDENCE Derrick Olds -- •�SolarCity BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: , NOR SHALL IT BE DISCLOSED IN WHOLE OR IN CompMount Type C 10470 SW KABLE ST 5.61 KW PV ARRAY PIN TO OTHERS OUTSIDE THE RECIPIENTS MODULES: TIGARD, OR 97224 ORGANIZATION, EXCEPT IN CONNECTION WITH w Way THE SALE AND USE OF THE RESPECTIVE (22) TRINA SOLAR # TSM-255PA05.18 3055 ClearyePAGE NAME: SHEET: REV: DATE: Son Mateo, CAe 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. ABB ; PVI-5000—OUTD—US—Z—A (503) 639-5893 COVER SHEET PV 1 9/30/2014 (888)-SOL-CITY(765-2489)www.solarcity.com PITCH: 24 ARRAY PITCH:24 MP1 AZIMUTH: 180 ARRAY AZIMUTH: 180 MATERIAL: Comp Shingle STORY: 2 Stories PITCH: 24 ARRAY PITCH:24 MP2 AZIMUTH: 180 ARRAY AZIMUTH: 180 10470 SW Kable St MATERIAL: Comp Shingle STORY: 2 Stories (E) DRIVEWAY Front Of House LEGEND O0 (E) UTILITY METER & WARNING LABEL AMITIOAV ' AC INVERTER W INTEGRATED DC DISCO ',`'tAiiiiii • 12" FSBI ��--I M, ® & WARNING LABELS ,, o o - • • ��i ����� 12" FSB 0 DC DC DISCONNECT & WARNING LABELS ., ``'1 v _ I0. 61 * �--1 AC DISCONNECT & WARNING LABELS I t M, = - ii `, ��� i • ` O DC JUNCTION/COMBINER BOX & LABELS ., o ' M ---Ja� MP2 ' ' `, D,.. /. . �,`Vt411111111 . DISTRIBUTION PANEL & LABELS "AA A '� ,, � ' Lc LOAD CENTER 8c WARNING LABELS ►&$, _.&al Wale*/`-���'��_' O DEDICATED PV SYSTEM METER /� � � �, � � A , Q STANDOFF LOCATIONS �•'I `,,' . 'I — CONDUIT RUN ON EXTERIOR --- CONDUIT RUN ON INTERIOR 41wrov GATE/FENCE 0 HEAT PRODUCING VENTS ARE RED I, ;I INTERIOR EQUIPMENT IS DASHED L-J SITE PLAN N TOTAL ARRAY AREA (SF): 396 Scale: 1/8" = 1' �+ TOTAL ROOF AREA (SF): 2362 w `+ E TOTAL ARRAY AREA IS a 16.75 0 1' 8' 16' PERCENT OF TOTAL ROOF AREA ■ 11. .. ____ S CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: J B-9722209 00 PREMISE OWNER: DESCRIPTION: -DESIGN: \`` CONTAINED SHALL NOT BE USED FOR THE SMITH, RICHARD SMITH RESIDENCE Derrick Olds ��`'� BENEFIT OF ANYONE EXCEPT IN WHOLE OR INC., MOUNTING SYSTEM: 1:D SolarCity PNOR ARTSTO OTHERS DISCLOOUTSIDSED THE RECIPIENTS IN Comp Mount Type C 10470 SW KABLE ST 5.61 KW PV ARRAY �1� ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: TIGARD, OR 97224 THE SALE AND USE OF THE RESPECTIVE (22) TRINA SOLAR # TSM-255PA05.18 3055 ClearvA Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEEP: REV: DATE: Son Mateo, CA 94402 PERMISSION OF SOLARCITY INC. INVERTER: (503) 639-5893 PV 2 9/30/2014 T:(650)636-1028 F:CA(695404)0L8-1029 ABB # PVI-5000-OUTD-US-Z-A SITE PLAN (888)—SOL—OTY(765-2489) www.sdorcity.com rO (E) 2x4 ier VIIIIIIIB (E) 2x4 ® / PRE—MANUFACTURED TRUSS .0, ,„,, .„„; PRE—MANUFACTURED TRUSS STRUCTURE MEETS THE ` 00111- \i" STRUCTURE MEETS THE PRESCRIPTIVE REQUIREMENTS PRESCRIPTIVE REQUIREMENTS �/ tiD � �� OF THE OSISC SECTION 305.4 �� OF THE OSISC SECTION 305.4 ,» �� k 1'-10" 4 5'-5" / 5'-9" / 4" '-10" 7'-4" / 7'-3" / + (E) LBW (E) LBW SIDE VIEW OF MP1 NTS B SIDE VIEW OF MP2 NTS CA) MP2 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 72" 24" STAGGERED LANDSCAPE 72" 24" STAGGERED PORTRAIT 48" 20" PORTRAIT 48" 20" ROOF AZI 180 PITCH 24 TOP CHORD 2x4 @ 24" OC ROOF AZI 180 PITCH 24 STORIES: 2 TOP CHORD 2x4 @ 24" OC ARRAY AZI 180 PITCH 24 STORIES: 2 ARRAY AZI 180 PITCH 24 BOT CHORD 2x4 @24"OC Comp Shingle BOT CHORD 2x4 @24" OC Comp Shingle PV MODULE 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. (4) ) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. ZEP COMP MOUNT C Air k � � ____ [1;f --- Z E P ZEP FLASHING C =t1`�tfE i _� --(;-3-_... INSERT FLASHING. (E) COMP. SHINGLE r:' . m (4) PLACE MOUNT. I0 (E) ROOF DECKING (5) INSTALL LAG BOLT WITH 5/16" DIA STAINLESS (5) SEALING WASHER. STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES -------- INSTALL LEVELING FOOT WITH WITH SEALING WASHER (6) BOLT & WASHERS. (2-1/2" EMBED, MIN) (E) RAFTER STANDOFF S i Scale: 1 1/2" = 1' • CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: JB-9722209 O O PREMISE OWNER: DESCRIPTION: DESIGN: tie CONTAINED SHALL NOT BE USED FOR THE SMITH, RICHARD SMITH RESIDENCE Derrick OldsBENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: 10 SolarCity NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount T e C10470 SW KABLE ST 5.61 KW PV ARRAY �� PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: TIGARD OR 97224 ORGANIZATION, EXCEPT IN CONNECTION WITHr THE SALE AND USE OF THE RESPECTIVE (22) TRINA SOLAR # TSM-255PA05.18 3055 t e,CA Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: San MoeoCA 94402 PERMISSION OF SOLARCITY INC. INVERTER:# (503) 639-5893 PV 3 9/30/2014 T:(650)638-1028 F:(650)638-1029 ABB PVI-5000-OUTD-US-Z-A STRUCTURAL VIEWS (888)—SOL—CITY(165-2489)www.soIarclt.aam UPLIFT CALCULATIONS 09.30.2014 SolarCity SleekMount'M PV System Version#39.1 • Structural Design Software Project Information&Table Of Contents Risk Category: II PV System Type SolarCity SleekMount'" Comp Roof Comp Roof Layers of Comp Roofing 1 Roof Slope 24° Rafter Spacing 24"O.C. PV System Module Orientation Landscape and Portrait PV Module Area 388 sf PV Module Width 39" PV Module Length 65" Standoff(Attachment Hardware) Comp Mount Type C Reduced Ground/Roof Live/Snow Loads Ground Snow Load pg 25.0 psf ' ASCE Table 7-1 Surrounding Roof Snow 100% 25.0 psf 'ASCE Eq:7.4-1 Roof Snow Over PV Modules 100% 25.0 psf 'ASCE Eq:7.4-1 Wind Design Criteria Wind Design Code ASCE 7-05 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 95 mph Fig.6-1 Exposure Category C Section 6.5.6.3 Roof Style Gable Roof 'Fig.6-11B/C/D-14A,1B Mean Roof Height h 25 ft Section 6.2 Effective Wind Area(1 Module) A 17.6 sf IBC 1509.7.1 Wind Pressure Calculation Coefficients Wind Pressure Exposure Kz 0.95 Table 6-3 Topographic Factor Kzt 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor I 1.0 Table 6-1 Velocity Pressure qh qh=0.00256(Kz)(Kzt)(Kd)(V^2)(I) Equation 6-15 18.6 psf Ext.Pressure Coefficient(Up) GCp(Up) -0.88 Fig.6418/CID-14A/B Ext.Pressure Coefficient(Down) GCp(Down) 0.45 Fig.6-11B/C/D-14A/B Design Wind Pressure p p=qh(GCp) Equation 6-22 Wind Pressure Up p(up) -16.3 psf Wind Pressure Down p(down) 10.0 psf Allowable Standoff Spacings X-Direction Y-Direction Max Allowable Standoff Spacing Landscape 72" 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib 20 sf PV Assembly Dead Load W-PV 3 psf Net Wind Uplift at Standoff T-actual -285 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacity DCR 57.0% Max Allowable Standoff Spacing Portrait 48" 65" Max Allowable Cantilever Portrait 20" NA Standoff Configuration Portrait Staggered Max Standoff Tributary Area Trib 22 sf PV Assembly Dead Load W-PV 3 psf Net Wind Uplift at Standoff T-actual -316 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacity DCR 63.3% J B—9722209 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: 14501a CONTAINED SHALL NOT BE USED FOR THE SMITH, RICHARD SMITH RESIDENCE Derrick Olds BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL L IT BE OUTSIDEED IN RECIPIENTS ORGANIZATION, IN Comp Mount Type c 10470 SW KABLE ST 5.61 KW PV ARRAY PART TO ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: TIGARD, OR 97224 THE SALE AND USE OF THE RESPECTIVE (22) TRINA SOLAR # TSM-255PA05.18 PAGE NAME: SHEET: REV: DATE: S 3055 Gearvi30 Mateo,Ceew Way 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. ABB # PVI-5000-OUTD-US-Z-A (503) 639-5893 UPLIFT CALCULATIONS PV 4 9/30/2014 (888)—SOL—CITY(765-2489)www.solorcity.com GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO TWO (N) GROUND Panel Number: Inv 1: DC Ungrounded INV 1 —(1)ABB # PVI-5000—OUTD—US—Z—A LABEL: A —(22)TRINA SOLAR # TSM-255PA05.18 OR # 180498 RODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:24523490 FCI Inverter; Zigbee 5000W, 240V, 96.57 PV Module; 255W, 232.2W PTC, 40MM, Black Frame, MC4, ZEP Enabled RGC, CGC1 Underground Service Entrance INV 2• Voc: 37.7 Vpmax: 30.5 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER (E) 200A MAIN SERVICE PANEL ADJUST MIN. ACTIVATION VOLTAGES! 1 Multiple Main Breakers (6 or fewer) (E) WIRING CUTLER—HAMMER COOPER Inverter 1 IND Disconnect Meter Socket 0 ABB i DC' Vstart = 181V PVI-5000—OUTD—US—Z—A DC- MP 2: 1x6 (E) LOADS A B _ EGC Lt ( 240V I I— r WC+ I �,�R• \ —1�Lz�— DC i I Vstart= DEFAULT 0- —• • y 1 FI ' N DC- I I C- ,�, /� 30A/2P I EGC! DC. �C. I GND _ GND�-— ❑ MP 1: 2x8 i, I +� A r rt----��f— �-- �� GEC 1N DC_ �G —• S-- t V EGC -GC J B I I®r--- ---- ----f--- --�'r I (1)Conduit Kit; 1' EMT N — J EGC/GEC -i Z-Z C., GEC r 1 TO 120/240V SINGLE PHASE I I UTILITY SERVICE I I i I I I I I I I I �__I__ Voc* = MAX VOC AT MIN TEMP POI_(1)MURRAY#MP230 PV BACKFEED BREAKER A -(1)CUTLER-HAMMER #DG221URB /f\ I . Breaker, 30A/2P, 2 Spaces Disconnect; 30A, 240Vac, Non—Fusible, NEMA 3R A —(2)Ground Rod; 5/8` x 8', Copper I —(1)CUTLER—HAMMER #DG03ONB Ground/Neutral Kit; 30A, General Duty(DG) B (1)COOPER #B—Line Meter Socket 011 Meter Socket; 125A, 4-14AWG, Ring Type —(1)AW CAP; B—Line Meter Socket Accessory —(1)Milbank #CL200D /Itron C1S Solid— ate Single—Phase Meter; Digital (1)AWG#10, THWN-2, Block I (2)AWG#10, PV WIRE, Black Voc* =253.71 VDC Isc =8.92 ADC O 1:::,";31—(1)AWG#10, THWN-2, Red O Icy'+(—(1)AWG#6, Stranded Bare Copper EGC Vmp =183 VDC Imp=8.36 ADC (1)AWG#10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=23 AAC 6666 ll (1)Conduit Kit; 3/4' EMT . . -(1)AWG#8,.THWN-2, Green EGC/GEC-(1)ConduitKit; 3/4".EMT. . . . . , . . . (4)AWG #10, PV WIRE, Block Voc* =338.27VDC Isc =8.92 ADC O I �(1)AWG #6, Stranded Bare Copper EGC Vmp =244 VDC Imp=8.36 ADC (1)Conduit Kit; 1' EMT J3-9722209 O O PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE IN BE USED N JOB NUMBER: � Ars SolarCity CONTAINED SHALL NOT BE USED FOR THE SMITH, RICHARD SMITH RESIDENCE Derrick Olds : BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: ;.'" PNOR ARTTOSHALL OIT BERS DISCLOUTSIOSED IN RECIPIENTS IN Comp Mount Type C 10470 SW K ABLE ST 5.61 KW PV ARRAY ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: TIGARD, OR 97224 arve THE SALE AND USE OF THE RESPECTIVE (22) TRINA SOLAR # TSM-255PA05.18 PAGE NAME: SHEET: REV: DATE: S 3055 an Mateo CleCle eCA ew y 9Waa SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN 02 INVERTER: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. ABB # PVI-5000—OUTD—US—Z-A (503) 639-5893 THREE LINE DIAGRAM PV 5 9/30/2014 (BBB)—SOL—CITY(765-2489)www.solarcity.com ELECTRICAL CALCULATIONSModule: 22 TRINA SOLAR#TSM255 ZEP 232.2 Inv Power WPIC Voltage Drop Calculations Version 5_8.0 Inverter 1: 1 ABB PVI 5000 S AFCI 0.965 5000 4929.61 Vdrop= Imp) * (2*Length)*(Resistance) / (Vmp) Module: Imp(A) Max.Length(ft) Wire Inverter 2: String: 8.36 65 AWG_10 at Max Ave Hi:87 deg F • Module: Vdrop= (8.36 * 130 *0.001240hms) / 200.9828 0.89 Inverter 3: Branch: 16.72 I 50 AWG_10 at Max Ave Hi:87 deg F Module: Vdrop= ( 16.72 * 100 *0.001240hms) / 200.9828 1.03 Total voltage drop in DC conductors= 1.93 • Inverter 4: Inverter: 8.36 20 AWG_10 at 240V Vdrop= (8.36 *40 *0.0012 Ohms) / 240 V 0.1672 Total: 22 Modules Total Inv Pwr: 5000 4929.61 FTC Combined: 0 0 AWG_10 at 240V Photovoltaic Module Electrical Specifications: Total STC: 5610 Vdrop= (0 *0 0.0012 Ohms) / 240 V 0 Voc: 37.7 V deg F deg C Vmp: 30.5 V Record Low Temp: 8 -13 Total voltage drop in AC conductors= 0.17 Isc: 8.92 A Max Average Hi Temp: 87 31 Total voltage drop in AC and DC conductors= 2.09 Imp: 8.36 A Record Hi Temp: 96 36 Tvoc: -0.12064 V/deg C Tisc: 4.1924 mA/deg C String Type A and 2 Combined Strings Type A Voc Correction Method: Manuf Tvoc data Branch Circuit Type A 1 way wire length: 50 Voc Correction Factor: ABB PVI-5000-S AFCI 2 strings per branch 1 1 strings per branch 2 Inverter Min Vdc Input: 120 8 TRINA SOLAR#TSM-255 ZEP 8 modules per series string 6 modules per series string Voc= 301.6 Min Vmp at Max Temp: 200.98 Voc= 301.6 V Voc= 226.2 V Max Voc at Min Temp: 338.27 Vmp= 244 Vmp= 244 V Vmp= 183 V Inverter Max Vdc Input: 600 Isc= 8.92 Isc= 17.84 A Isc= 8.92 A Imp= 8.36 Max String Size: 14 Imp= 16.72 A Imp= 8.36 A Icont= 11.15 Art 690.8(A)(1) 1-way wire length: 65 Icont= 22.3 A Icont= 11.15 A Art 690.8(A)(1) 1.a Conductor: AWG_10 PV Wire 2.a Conductor 1: AWG_10 Conductor 2: AWG_10 Icont*1.25=(Amps) 13.94 Conductor 1 Conductor 2 30 deg C ampacity= 40 Icont"1.25=(Amps) 27.88 13.94 1.b Icont=(Amps) 11.15 30 deg C ampacity= 40 40 Start ampacity 40 2.b Icont=(Amps) 22.3 11.15 Temperature derate(%=F) 0.76 Start ampacity 40 40 Conduit fill derate(%=#) 1 Temperature derate(%=F) 0.76 0.76 Derated ampacity 30.4 Conduit fill derate(%=#) 0.8 0.8 1.c Derated ampacity 24.32 24.32 Icont*1.25=(Amps) 13.94 2.c Term 1 Term 2 Ampacity 40 Temp table 75degC 75degC Icont"1.25=(Amps) 27.88 27.88 1.d Icont*1.25=(Amps) 13.94 Ampacity 35 35 OCP Size= 15 Inverter Type A Output 2.d OCP Size= 30 15 ABB PVI-5000-S AFCI 1 way wire length: 10 ft Combined Inverter Output Icont= 23 'A Art 690.8(A)(1) Service Voltage= 3.a Icont"1.25=(Amps) 28.75 Art 690.8(B)(1) Total Inverter Power= 1 way wire length= 0 OCP Size= 30 Art 240.6(A) Icont=#of inverters*max inverter current Art 690.8(A)(1) 3.b Conductor: AWG_10 THWN-2 at 90 deg C:Table 310.16 Icont=(Amps) Icont*1.25=(Amps) 28.75 4.a Icont"1.25=(Amps) 28.75 Art 690.8(B)(1) 30 deg C ampacity= 40 OCP size= 30 Art 240.6(A) 3.c Icont=(Amps) 23 4.b Conductor: AWG 10 THWN-2 at 90 deg C:Table 310.16 Start ampacity 40 Icont"1.25=(Amps) 28.75 Temperature derate(%=F) 0.91 30 deg C ampacity= 40 Conduit fill derate(%=#) 1 4.c Icont=(Amps) 23 Derated ampacity 36.4 Start ampacity 40 3.d Icont"1.25=(Amps) 28.75 Temperature derate(%=F) 0.91 Ampacity 35 Conduit fill derate(%=#) 1 Derated ampacity 36.4 4.d (cont"1.25=(Amps) 28.75 Ampacity 35 CONFIDENTIAL JB-9722209 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: ��\!� CONTAINED SHALL NOT BE USED FOR THE SMITH, RICHARD SMITH RESIDENCE Derrick Olds ;,,SoIarCity BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: dela NOR SHALL IT BE DISCLOSED IN WHOLE OR IN CompMount Type C 10470 SW KABLE ST 5.61 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: TIGARD, OR 97224 ORGANIZATION, EXCEPT IN CONNECTION WITH 3055 Clearview Way THE SALE AND USE OF THE RESPECTIVE (22) TRINA SOLAR # TSM-255PA05.1 8 PAGE NAME: SHEET REV DATE: San Mateo, CA 94402 29 PERMISSIONSOLARCITY EOFIPMENT,SOLARCITY INC. (503) THE WRITTEN INVERTER: T9 2014 (888)(SOL)CITY(765-2489)2 ) 5 www.sola0) rcity.com ABB # PVI-5000-OUTD-US-Z-A 639-5893 ELECTRICAL CALCULATIONS PV 6 /30/ Label Location: Label Location: Label Location: CAUTION: SOLAR CIRCUIT (C)(IC)(CB) MAXIMUM AC _ A (AC) (P01) CAUTION (P01) - Per Code: OPERATING CURRENT Per Code: DUAL POWER SOURCE Per Code: IFC 605.11.1.4 MAXIMUM AC _ v NEC 690.54 SECOND SOURCE IS NEC 690.64.6.4 - OPERATING VOLTAGE PHOTOVOLTAIC SYSTEM Label Location: PHOTOVOLTAIC DC (DC) (INV) DISCONNECT Per Code: NEC 690.14.C.2 Label Location: Label Location: PV SYSTEM (AC) WARNING (DC) (INV) DISCONNECT FOR Per Code: UTILITY OPERATION ELECTRIC SHOCK HAZARD NEC 690.35(F) Label Location: - THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE TO BE USED WHEN MAXIMUM POWER-_A (DC) (INV) UNGROUNDED AND INVERTER IS POINT CURRENT(Imp) Per Code: MAY BE ENERGIZED UNGROUNDED MAXIMUM POWER--v NEC 690.53 POINT VOLTAGE(Vmp) Label Location: MAXIMUM SYSTEM V VOLTAGE(Voc) WARNING (AC) (P01) SHORT-CIRCUIT CURRENT(Isc) A ELECTRIC SHOCK HAZARD Per Code: DO NOT TOUCH TERMINALS NEC 690.17(4) TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION Label Location: WARNING (DC) (CB) Per Code: ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS NEC 690.17(4) Label Location: TERMINALS ON BOTH LINE AND WARNING (P01) LOAD SIDES MAY BE ENERGIZED Per Code: IN THE OPEN POSITION INVERTER OUTPUT NEC 690.64.6.7 . DC VOLTAGE IS CONNECTION ALWAYS PRESENT WHEN DO NOT RELOCATE SOLAR MODULES ARE THIS OVERCURRENT EXPOSED TO SUNLIGHT DEVICE Label Location: Label Location: WARNING (DC) (INV) PHOTOVOLTAIC POINT OF (P01) Per Code: INTERCONNECTION Per Code: ELECTRIC SHOCK HAZARD NEC 690.5(C) WARNING: ELECTRIC SHOCK NEC 690.17.4; NEC 690.54 IF A GROUND FAULT IS INDICATED HAZARD.DO NOT TOUCH NORMALLY GROUNDED TERMINALS.TERMINALS ON CONDUCTORS MAY BE BOTH THE LINE AND LOAD SIDE UNGROUNDED AND ENERGIZED MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER. PV POWER SOURCE MAXIMUM AC Label Location: A OPERATING CURRENT (AC): AC Disconnect PHOTOVOLTAIC AC (AC) (P01) MAXIMUM AC _ (C): Conduit DISCONNECT Per Code: OPERATING VOLTAGE (CB): Combiner Box NEC 690.14.C.2 (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit Label Location: (INV): Inverter With Integrated DC Disconnect CAUTION (D) (P01) (LC): Load Center PHOTOVOLTAIC SYSTEM Per Code: (M): Utility Meter • CIRCUIT IS BACKFED NEC 690.64.8.4 (P01): Point of Interconnection CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR N,k1I THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED ������ 3055 Cleayiew Way San Mateo,CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, SC - OR Label Set ���� T:(650)638-1028 F:(650)638-1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE /� SoIaI1Cu1.y (888)-SOL-CITY(765-2489)www.solarcity.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. i ZS Comp Edge Zone Calculations 1 of 4 ZS Comp Edge Zone Calculations 2 of 4 Pr pU r 5/28/13 Zep a r 5/28/13 This set of calculations is intended to show that ZS Comp has sufficient strength to allow for attachment Down Force Spacing spacings of at least 48"in Edge Zones whether the modules are orientated in landscape or portrait.The Allowable Down Force Load down force spacing= calculations will vary the design variables to account for the worst case for each failure mode that is being module width x design load checked. Wind Down Calculations All variable the same as above except for roof pitch General Design Information: Roof Pitch Module Size: 39"x 65" Basic Wind Speed= 95 mph 14 30 45 System Weight= 3 psf Ground Snow Load= 30 psf GCN landscape= 0.5 0.9 0.9 GCN portrait= 0.4 0.9 0.9 Comp Mount Allowable Loads Uplift= 656 lbs design load landscape= 9.62 17.32 17.32 psf Lateral= 436 lbs design load portrait= 7.70 17.32 17.32 psf Down Force= 1147 lbs - 'Ro ,x.11 note:use 10 psf minimum - - if7r •�r�►r:til Snow Calculations Attachment Spacing Calculations 85818 To account for unbalanced snow loads,ground snow loads will be used for roof pitches 30 degrees and Uplift Spacing ,o OREGON o lower.Per section 7.6.1 of ASCE 7-10 unbalanced snow loads do not need to be considered for slopes 'Ilk ro 5P above 30 degrees. Allowable Uplift Load F'CtMY RGGC uplift spacing= module length or width x design load EXPIRES: 12/31/14 Ground Snow Load= 30 psf Wind Uplift Calculations FOR PAGES 1-4 Roof Pitch ASCE 7-05 Method 2 14 30 Design Snow Load 29.11 25.98 psf p=ghGCN qh=0.00256 KZ K,Kd V2 I (snow load spread over the length of the rafter) Basic Wind Speed= 95 mph Down Force Load Roof Pitch Exposure= C Roof Zone= Edge Zone Combinations: 14 30 Importance Factor= 1.0 KZ= 0.98 from Table 6-3 D+S= 31.16 25.10 psf Gable/Hip Roof Kit= 1.0 per 6.5.7.2 D+W= 12.91 19.92 psf /orst Case Roof Pitch= 14 degrees Kd= 0.85 from Table 6-4 D+0.75W+0.755 31.59 32.46 psf Roof Height= 30 GCN landscape= -1.6 iscape effective area= 13.0 ft2 GCN portrait= -1.5 landscape down force spacing = 39"x132.46 s x 144 in = 130" ortrait effective area= 21.7 ft2 p f f plandscape= -30.79 psf qh= 19.25 psf Pportrait= 28.87 psf 1147Ibs portrait down force spacing = 65"x32.46ps f x 144 in t2 = 78" Uplift Load Combination:0.6D+W(ASCE Section 2.4.1 equation 7) design load landscape= -29.05 psf design load portrait= -27.12 psf 656 lbs in landscape uplift spacing = 39"x 29.05 psf x 144 f=83" tZ 656 lbs in portrait uplift spacing = 65"x 27.12 psf x 144 ft2 = 54" ZS Comp Edge Zone Calculations 3 of 4 ZS Comp Edge Zone Calculations 4 of 4 5/28/13 5/28/13 ZepSoLor ZepSolar Lateral Spacing Module Deflection Spacing The lateral force on the system increases as the pitch of the roof increases,but the amount of snow on landscape module spacing = -1.4545 x Maximum Uplift or Down Force Pressure+120.7273 the roof decreases for slopes greater than 30 degrees.With this in mind,the lateral force will be checked at 30 degrees with ground snow load and 45 degrees with sloped roof snow. portrait module spacing=-1.7917 x Maximum Uplift or Down Force Pressure+118.58 Allowable Lateral Load lateral spacing= module width x design load Maximum Uplift of Down Force Pressure= 32.46 psf Snow Calculations Ground Snow Load= 30 psf landscape module spacing=-1.4545 x 32.46 psf+120.7273 = 73" PS=C5 Pf Roof Pitch= 31 45 degrees pf=0.7 Ce Ct I pg Ce= 0.9 C5= 0.71 0.45 Ct= 1.2 pf= 22.68 22.7 psf portrait module spacing=-1.7917 x 32.46 psf+118.58= 60" I= 1.0 p5= 16.1 10.2 psf Calculation Summary Calculated Edge Zone Spacing Roof Pitch Spacing Check Landscape Portrait 27 30 31 45 Uplift 83" 54" Design Snow Load 26.73 25.98 13.80 7.22 psf Down Force 130" 78" (snow load spread over the length of the rafter) 30° Lateral 30° 2T 74" 48" 45" • Lateral Force Component Module Deflection 73" 60" Down Force Load Roof Pitch Combinations: 27 30 31 45 As can be seen in the table above,for Design Wind Speeds up to 95 mph and Ground Snow Loads up to 30 D+S= 13.50 14.49 8.65 7.22 psf psf with modules orientated in landscape,the system is strong enough to be installed at 72"on center in D+0.75W+0.755 10.46 11.24 6.88 5.95 psf the Edge Zone.When modules are installed in portrait,the spacing for edge zone installations can be 48" on center for most roof pitches.For roof pitches that are greater than 27°but less than 31°,the maximum 30 degree roof pitch attachment spacing is 45". 292lbs in landscape lateral spacing= 39"x 14.49 psf x 144 Ft = 74" 292lbs /in portrait lateral spacing = Ft2 65"x 14.49 psf x 144 =45" Portrait spacing is less than 48".Try roof pitch of 27 degrees 292lbs in portrait lateral spacing = x 144 65"x 13.50 psf ft2 =48" SolarCity SleekMountTM — Comp SolarCity SleekMountTM — Comp The SolarCity SleekMount hardware solution •Utilizes Zep Solar hardware and UL 1703 listed ..» — \ Installation Instructions is optimized to achieve superior strength and Zep CompatibleTM modules � q aesthetics while minimizing roof disruption and • Drill Pilot Hole of Proper Diameter for labor.The elimination of visible rail ends and •Interlock and grounding devices in system UL listed to UL 2703 Fastener Size Per NDS Section 1.1.3.2 mounting clamps, combined with the addition •Interlock and Ground ZepETL listed to UL 1703 —. • Seal pilot hole with roofing sealant of array trim and a lower profile all contribute to a more visually appealing system.SleekMount as"Grounding and Bonding System" • Insert Comp Mount flashing under upper utilizes Zep CompatibleTM modules with •Ground Zep UL and ETL listed to UL 467 as \ layer of shingle strengthened frames that attach directly to grounding device • Place Comp Mount centered Zep Solar standoffs,effectively eliminating the ' need for rail and reducing the number of •Painted galvanized waterproof flashing upon flashing standoffs required. In addition, composition •Anodized components for corrosion resistance • Install lag pursuant to NDS Section 11.1.3 shingles are not required to be cut for this with sealing washer. system,allowing for minimal roof disturbance. •Applicable for vent spanning functions '• • Secure Leveling Foot to the Comp Mount using machine Screw 1 • Place module Components c-.0_ , er, ___ A 5/16"Machine Screw � � B Leveling Foot ----__ C: Lag Screw ® • Comp Mount Te t, • „ • Comp Mount Flashing 0 oO l0 o�' %il I IIII I I I I I 00 q .`all OP x 43 li SolarCity J 0 LISTED p 4 SolarCity®SolarCuty® January 2013 "pcO� m January 2013 TSM-PA05.18 TRINAMOUNT II WITH THE UNIVERSAL MODULE • Mono Multi Solutions DIMENSIONS OF PV MODULE TSM-PA05.18 ELECTRICAL DATA @ STC TSM-240 TSM-245 TSM-250 TSM-255 TSM-260 • PA05.18 PA05.18 PA05.18 PA05.18 PA05.18 941mm Peak Power Watts-Pox,(Wp) 240 245 250 255 260 , Power Output Tolerance-Pox,(MI 0/+3 0/+3 0/+3 0/+3 0/+3 • a r000 Maximum Power Voltage-VMr'(V) 29.7 30.2 30.3 30.5 30.7 Maximum Power Current-IMP,(A) 8.10 8.13 8.27 8.36 8.47 M PA05.18 ISALL r'rAreOpen Circuit Voltage-Voc(V) 37.3 37.5 37.6 37.7 37.9 HsrAwHCHoie Short Circuit Current-Isc(A) 8.62 8.68 8.85 8.92 9.00 Module Efficiencyn (%) 14.7 15.0 15.3 15.6 15.9 T H E T R I N A M O U NT MODULE ATC Irradiance reduction of 4.5%at 200 W/m'according to EN 60904-I. E E o 3 ELECTRICAL DATA NOCT TSM-240 TSM-245 TSM-250 TSM-255 TSM-260 PA05.18 PA05.18 PA05.18 PA05.18 PA05.18 60 CELL Maximum Power-Pox,(Wp) 174 178 181 184 188 Maximum Power Voltage-VMr'(V) 26.6 26.8 27.0 27.2 27.4 MULTICRYSTALLINEMQDULE 604u,ocraNerr A A Maximum Power Current-Ion=(A) 6.55 6.64 6.70 6.77 6.86 WITH TRINAMOUNT FRAME / 1pPA1NHoa Open Circuit Voltage(V)-Voc(V) 34.1 34.2 34.3 34.4 34.6 Short Circuit Current(A)-Isc(A) 7.04 7.10 7.25 7.31 7.37 I812mm I h 180 I NOCT:Irradiance at 800 VIII',Ambient Temperature 20°C,Wind Speed I m/s. 240-260W Back View POWER OUTPUT RANGE Our most versitile product MECHANICAL DATA 1-1-L-1Solar cells Multicrystalline 156x 156 mm(6 inches) • • Compatible with all major BOS components and system designs Cell orientation 60 cells(6 x 10) • Module dimensions Weight 1650•992 x 40 mm(64.95•39.05'r 1.57 inches) 18.6 kg(41.0 lbs) MAXIMUM EFFICIENCY f 1 Glass High transparency solar glass 3.2mm(0.13 inches) Backsheet White One of the industry's most trusted modules • Over 2 GW sold across all major global markets Frame Black Anodized Aluminium Alloy with Trinamount Groove �•�� 0~+3vJ- • Field proven performance I-V CURVES OF PV MODULE TSM-245 PA05.18 J-Box IP 65 or IP 67 rated Cables Photovoltaic Technology cable 4.0 mm'(0.006 inches'), 10.0 1100 mm(43.3 inches) POWER OUTPUT GUARANTEE 9m 10^OW/m' Connector Original MC4 800 7m m' 800W/m' Highly reliable due to stringent quality control <bm-- / 5W As a leading global manufacturer • Over 30 in-house tests(UV,TC,HF,and many more) u 4.m--40eW/m'-- TEMPERATURE RATINGS MAXIMUM RATINGS of next generation photovoltaic • In-house testingwell be oncertificationrequirements 3. goes beyong 200 200w/m2 \ Nominal Operating Cell 45°C(±2°C) Operational Temperature -40-+85°C products,we believe close 1 \ Temperature(NocT) cooperation with our partners \ Maximum System 1000V DC(IEC)/ om Temperature Coefficient of Pox, -0.43%/°C Voltage 600V DC(UL) is critical to success. With local op 10. 20.00 30.. 40.. presence around the globe,Trina isVoltage(V( Temperature Coefficient of Voc -0.32%/°C Max Series Fuse Rating 15A able to provide exceptional service to each customer in each market Temperature Coefficient of Isc 0.047%/°C ---- -- ---i and supplement our innovative, Certified to withstand challenging environmental reliable products with the backing conditions i of Trina as a strong,bankable • 130 km/hr wind load (2400 Pa) WARRANTY partner. We are committed • 900 kg snow load per module (5400 Pa) 10 year Product Workmanship Warranty to building strategic,mutually beneficial collaboration with 25 year Linear Power Warranty installers,developers,distributors (Please refer to product warranty for details) ce and other partners as the = backbone of our shared success in CERTIFICATION driving Smart Energy Together. LINEAR PERFORMANCE WARRANTY ( �If' PACKAGING CONFIGURATION 10 Year Product Warranty•25 Year Linear Power Warranty A \ „; Fait `,M.etek spas Modules per box:24 pieces Trina Solar Limited www.trinasolar.com Or e I PY�E•Y~CLL Modules per 40'container 672 pieces 100% ISO tq C E Addfiiorlaf value 6 v IxrEo o 0 90% A°'" Trf4a$Ofa�S ffnear N'affant CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. pOMiATjA T• `o y • ©2013 Trina Solar Limited.All rights reserved.Specifications included in this datasheet are subject to in, rinasolar 0 80% ,. •Tr�nasolar change without notice Smart Energy TogetherYears 10 15 20 25 Smart Energy Together %MPpto tandard Ill Trina Solar Additional highlights: Solar inverters — RS-485 communication interface • \BB string inverters (for connection tolaptop ordata I logger). PVI-5000/6000-TL-OUTD — Integrated Arc Fault Detection and 5kW to 6kW Interruption(-A Version). AR f MI Technical data and types Type code PVI-5000-OUTD-US PVI-6000-OUTD-US ARK Input side Nominal output power 5000W 6000W tt- ..,;. liiMaximum output power 5000W 6000W Rated grid AC voltage 208V 240V 277V 208V 240V 277V 'k Input side(DC) ° ': Number of independent MPPT channels 2 . Maximum usable power for each channel 4000W Absolute maximum voltage(Vmax) ...._ ... 600V _ Start-up voltage(Vstart)......... ....... .... ........... .... ....... 200V(ad1...120 350)....:..._ Full power MPPT voltage range 200 530V j Operating MPPT voltage range 0.7 x Vstart-580V lip Maximum current(Idcmax)for both MPPT in parallel 36A Maximum usable current per channel 22A Number of wire landing terminals per channel 2 Pairs t Array wiring termination Terminal block,pressure clamp,AWG16-AWG6 Output side(AC) Grid connection type 10/2W Split-0/3W 10/2W 10/2W Split-0/3W 10/2W Adjustable voltage range(Vmin Vmax) 183V 228V 221V 264V 244V-304V 183V 228V 211V-264V 244V 304V Grid frequency 60Hz Adjustable grid frequency range 57 60.5Hz Maximum current Ow...)Anus ......._27'.us........ ._.?3Awes .:. 20A,,,,,s 30A s.,....... 2S ws .......?4&s......... Designed for residential and small The wide input voltage range Highlights: Power factor >0.995 9 Total harmonic distortion at rated power <2% makes the inverter suitable to low commercial PV installations,this - Single phase and split phase output Contributory fault current' 36.25 Apk/... 36.5 Apk/ 31.75 Aok/ 36.25 Apk/ 36.5 Apk/ 31.75 A / ..... inverter fills a specific niche in the power installations with reduced grid connection. Grid wiring termination type 25 63AgMs.... 25 Terminal block,pressure camp,AWG14-AWG4 22.45A,„„._., stringsize. ABB product line to cater for those - Wide input range for increased Input installations producing between The transformerless operation offers stringing flexibility. Reverse polarity protection Yes high performance efficiencies of up to Over voltage protection type Varistor,2 for each channel 5kW and 20kW. - The high speed and precise MPPT - e 97.1%. PV array ground fault detection Pre start-up Riso and Dynamic GFDI(requires floating arrays) algorithm offers real time power Output This inverter includes dual input Free remote monitoring capability tracking and improved energy Anti-islanding protection Meets UL 1741/IEEE1547 requirements Meets UL 1741/IEEE1547 requirements available with everyinstallation.This Over voltage protection type Varistor,2(L,-L2/1,-G) Varistor,2(L, L2/L,-G) section to process two strings withharvesting. enables homeowners to view their Maximum AC OCPD Rating 35A 30A 25A 40A 35A 30A independent MPPT. - Outdoor NEMA 4X rated enclosure Efficiency The high speed and precise MPPT energy production and offers installers for unrestricted use under any Maximum efficiency 97.1% algorithm offers real-time power a proactive and economic way of environmental conditions. CEC efficiency 96% 96.5% 96.5% 96% 96.5% 96.5% maintainingand troubleshootingthe - User interface Graphic display Graphic display tracking and energy harvesting. Integrated DC disconnect switch Operating performance stem. Flat efficiency curves ensure high system. in compliance with international Stand-by consumption <BwaMs <BwAMs efficiency at all output levels ensuring Standards(-S Version). Night time consumption <0.6W, <0.6W, Communication consistent and stable performance User-interface 16 characters x 2 lines LCD display across the entire input voltage and Remote monitoring(1xR5485 incl.) VSN700 Data Logger(opt) 2. OUtpUt power range. Wired local monitoring(1xRS485 incl.) PVI-USB-RS485_232(opt.) Environmental This outdoor inverter has been 13°F to+140°F(-25°C to+60°C)with Ambient air operating temperature range 13°F to+140°F(-25°C to+60°C) deratingabove 122°F 50°C designed as a completely sealed unit to ( ) withstand the harshest environmental Ambient air storage temperature range 40°F to+176°F(-40°C to+80°C) -40°F to+176°F(-40°C to+80°C) Relative humidity 0-100%RH condensing 0-100%RH condensing conditions. Acoustic emission level <50 db(A)@1m <50 db(A)@1 m „ ,I ,t g Maximum operating muchaltitutde without derating 6560 ft(2000 m) 6560 ft(2000 m) Power and productivity 2.inverter can apply that much current Breaker wit open for a better world'" P11,.,. 2 ABB Solar Inverters I Product flyer for PVI-5000/6000-TL-OUTD