Plans (17) PITCH: 22 ARRAY PITCH:22 MP1 AZIMUTH:250 ARRAY AZIMUTH: 250 MATERIAL: Comp Shingle STORY: 2 Stories PITCH: 22 ARRAY PITCH:22 • MP2 AZIMUTH:250 ARRAY AZIMUTH:250 0cMATERIAL: Comp Shingle STORY: 2 Stories ® Ac —4 3' FSB • ,____— U I N r -I- �C 0 i I- 3 (E)DRIVEWAY SnZ rLLL__it3. 650 3 .- - o 1111 Lo i, M A .--�p7 , PV3 I I P T d O I I 1\ LEGEND 0 (E) UTILITY METER & WARNING LABEL ® INVERTER W/ INTEGRATED DC DISCO I / & WARNING LABELS I • I A DC DISCONNECT & WARNING LABELS El I I A AC DISCONNECT & WARNING LABELS IN 0 DC JUNCTION/COMBINER BOX & LABELS Front Of House0 h iQ 1 0 DISTRIBUTION PANEL & LABELS ❑ 'I LC LOAD CENTER & WARNING LABELS I — J M O DEDICATED PV SYSTEM METER 3'FSB STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR .R GATE/FENCE 0 HEAT PRODUCING VENTS ARE RED 1( i INTERIOR EQUIPMENT IS DASHED L.J SITE PLAN N TOTAL ARRAY AREA (SF): 791 = 1' W TOTAL ROOF AREA (SF): 2495 Scale: 3/32" W, F TOTAL ARRAY AREA IS a 31.71 01' 10' 21' PERCENT OF TOTAL ROOF AREA I— S CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: JB-9722237 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE BURNS, MICHAEL BURNS RESIDENCE Aaron Banks `alt, BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: ���SoIarCityNOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C13605 SW GARRETT CT 11.22 KW PV ARRAY ►r PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES TIGARD, OR 97223 ORGANIZATION, EXCEPT IN CONNECTION 111TH THE SALE AND USE OF THE RESPECTIVE (44) TRINA SOLAR # TSM-255PA05.18 3055 earview Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME. SHEET: REV: DATE Sin Mateo,CA 94402 PERMISSION OF SOLARCITY INC. INVERTER' 5037899343 T:(650)638-1028 F:(650)638-1029 Multiple InvertersSITE PLAN PV 2 10/27/2014 (888)—SOL—CITY(765-2489)www.sdarcity.com (E) 2x4 11 (E) 2x4 11 lir ® PRE—MANUFACTURED TRUSS ® PRE—MANUFACTURED TRUSS STRUCTURE MEETS THE STRUCTURE MEETS THE PR f PRESCRIPTIVE REQUIREMENTS fi OF EPTIVE THE IOSISC SECCTIIONMENTS 305.4 OF THE OSISC SECTION 305.4 ' r - —/ 7'-5" / 6'-9" / 6'-10" / 6'-10" / 6'-8" / 6'-9" / 6'-10" / G'-10 1'-4. (E) LBW 1'— (E) LBW SIDE VIEW OF MP1 NTS..A_.) 0 SIDE VIEW OF MP2 NTS MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 72" 24" STAGGERED MP2 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 72" 24" STAGGERED PORTRAIT 48" 20" PORTRAIT 48" 20" TOP CHORD 2x4 @ 24"OC ROOF AZI 250 PITCH 22 STORIES:2 ROOF AZI 250 PITCH 22 ARRAY AZI 250 PITCH 22 TOP CHORD 2x4 @ 24"OC ARRAY AZI 250 PITCH 22 STORIES:2 BOT CHORD 2x4 @24"OC Comp Shingle BOT CHORD 2x4 @24"OC Comp Shingle PV MODULE 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS ...--- LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. (4) (2) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. ZEP COMP MOUNT CA,',1124110/41111118110 ■101440� 1 ZEP FLASHING C ,"��t� �� (3) INSERT FLASHING. rs�ja1- -...._jV— (E) COMP. SHINGLE i ; limiii- (4) PLACE MOUNT. (E) ROOFMP MOUNTVALCII Mil LAG BOLT WITH - 5/16" DIA STAINLESS (5) (5) SEALING WASHER. STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH WITH SEALING WASHER (6) BOLT & WASHERS. _ (2-1/2" EMBED, MIN) (E) RAFTEReD STANDOFF Scale: 1 1/2" = 1' CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE JB-9722237 00 ` t,SolaiCity BURNS, MICHAEL BURNS RESIDENCE Aaron Banks BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM "I„ NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 13605 SW GARRETT CT 11.22 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES TIGARD OR 97223 ORGANIZATION, EXCEPT IN CONNECTION WITH , 3055 geaMew Way - THE SALE AND USE OF THE RESPECTIVE (44) TRINA SOLAR # TSM-255PA05.18 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN NvERER: PAGE NAME: SHEET: REV: DATE: San Mateo,CA 94402 PERMISSION OF SOLARCITY INC. Multiple Inverters 5037899343 STRUCTURAL VIEWS PV 3 10/27/2014 (888)-sa-a 638-1028 F:(650) aeitYaam UPLIFT CALCULATIONS X4 9 10.27.2014 SoIarCit1. SleekMountTM PV System Version#39.5 Structural Desian Software Project Information ak Table Of Contents Risk Category: II PV System Type SolarOty SleekMOunt'K Comp Roof Comp Roof Layers of Comp Roofing , 1 Roof Slope 22° Rafter Spacing 24"O.C. PV System Module Orientation Landscape and Portrait - PV Moue Area 740 sf PV Module Width 39" PV Module Length 65" Standoff(Attachment Hardware) Comp Mount Type C Reduced iRoof Live/Snow Loads Ground Snow Load pg 25.0 pit ' ASCE Table 7-1 Surrounding Roof Snow 108% 25.0 psf 'ASCE Eq:7.4-1 Roof Snow Over PV Modules 100% 25.0 psf 'ASCE Eq:7.4-1 Wind oitakUt t rWaria Wind Design Code ASCE 7-05 ' Wind Deggn Method Partiafly/Fully Endosed Method Basic Wind Speed V 95 mph ' Fig.6-1 Exposure Category C ' Section 6.5.6.3 Roof Style Gable Roof 'Fig.6-11BJC/D-14A/B Mean Roof Height h 25 ft Section 6.2 Effective Wind Area(1 Module) A 17.6 sf IBC 1509.7.1 Wind Ikassaare Cmaplation Coefftdents Wind Pressure Exposure Kz 0.95 Table 6-3 Topographic Factor Kzt 1.00 Section 6.5.7 I Wind Directionality Factor Kd 0.85 Table 6-4 Importance Fad 1 1.0 Table 64 Velocity Pressure qh qh=0.00256(Kz)(Kzt)(Kd)(Y^2)(I) Equation 6-15 18.6 psf Ext.Pressure Coefficient(Up) GCp(Up) -0.88 Fig.6-118/C/D-14A/B Ext Pressure Coefficient(Down) GC9(Down) 0.45 rg 6-UBICID-4MB Design Wind Pressure p p=qh(GCp) Equation 6-22 Wind Presume Up p(rga) -16.3 psf Wind Pressure Down p(down) 10.0 psf Allosaile Sendoff X-1Nrec ion Y Max Allowable Standoff Spacing Landscape 72" 39" Max Allowithle Cantilever Lame 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Tri 20 s( PV Assembly Dead Load W-PV 3 psf Net Wind Uplift at Standoff T-adual -285 roe Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/CaparitY DGR 56.9% Max Allowable Standoff Spacing Portrait 48" 65" Max Allowable Portrait 20" NA Standoff Configuration Portrait Staggered Max Standoff Tributary Area Tit 22 sf' PV Assembly Dead Load W-PV 3 psf Net Wind Uplift at Standoff Tactual -316 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff DernandICanadtV DO 63.1% CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: J B-9722237 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: `���t� v CONTAINED SHALL NOT E USED FOR THE BURNS, MICHAEL BURNS RESIDENCE Aaron Banks ':,;So�arCity. BENEFlT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: — - �.�$ NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 13605 SW GARRETT CT 11.22 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MDDULEs TIGARD OR 97223 ORGANIZATION, EXCEPT IN CONNECTION WITH � THE SALE AND USE OF THE RESPECTIVE (44) TRINA SOLAR # TSM-255PA05.18 PAGE NAME: SHEET: REV: DATE: s3��Mateo,CA 94402 CleaMew Woy SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. Multiple Inverters 5037899343 UPLIFT CALCULATIONS PV 4 10/27/2014 (886)—SCI—CITY(765-2489)www.edaraty.com GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO E GROUND ROD Panel Number: Inv 1: DC UngroundedOR # 180498 ( ) INV 1 -(1)ABB #PVI-3.6-OUTD-S-US-Z-A LqgEL: A -(44)TRINA SOLAR TSM-255PA05.18 AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:24 525 076 Inv 2: DC Ungrounded FCI Inverter; Zigbee 3600W, 240V, 96% PV Module; 255W, 232.2W PTC, 40MM, Black Frame, MC4, ZEP Enabled RGC, CGC1 Underground Service Entrance Tie-In: Supply Side Connection INV 2-(1)ABB #PVI-6000-OUTD-US-Z-A MEL: B FCI Inverter; Zigbee 6000W, 240V, 96.52 Voc: 37.7 Vpmax: 30.5 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 200A MAIN SERVICE PANEL E 200A/2P MAIN CIRCUIT BREAKER Inverter 1 IND CUTLER-HAMMER BRYANT Disconnect CUTLER-HAMMER COOPER (N) 125A Load Center © Vstart= DEFAULT rrii 0 Disconnect Meter Socket © ABB . Dc+ A 60ADPVI-3.6-OUTD-S-US-Z-A11.1� , MP 1: 1x8 IrlirilL oB20A/2PEMI EccA £ A , L+ r/ B SI• =BIM -NM MAE EI®� DC+ I 200A 2P ■_ `` IIS■= _■M _■•_, ■■©� D4 I I, ■ I _ its ,_ , - - __ I_EGC/ ___ Dc+ Dc+ Vstart = DEFAULT (E) LOADS - - - - -_I GND -- , r GEC m I� l • ' I Ip - Da -- -- �����,ir MP 1: 1x8 -� • r----J I T I I GND I _ EGC- --f-- EGC (1)Conduit Kit; 1" EMT N I I Inverter 2 IND 0 I ABB 3 DC, Vstart= DEFAULT c I I Z-z I I PVI-6000-OUTD-US-Z-A DC- MP 2: 1x14 -I I I 35A/2P EGC 1240V I I A L+ J T--- - GEC♦ ��®_ ,I.---- DC+ 1 TO120/240V 1 iill MUM �i Dc 1 SINGLE PHASE 1 Vstart= DEFAULT I L_ M ____ I_EGC/ __- •� DC+ DC+ UTILITY SERVICE I GEC i© • __._-- 1 +/ DG DC- MP 2: 1x14 I GND I----EGC--- ------- - _� EGC I 1/L V I (1)Conduit Kit; 1" EMT J- Voc* = MAX VOC AT MIN TEMP POI- 2)ILScO L'IPC 4 0- A (1)CUTLER-HAMMER DG222NRB ( Insula ion Piercing Connector; Main 4/0-4, Tap 6-14 Disconnect; 60A,#240Vac, Fusible, NEMA 3R AC DC D -(1)CUTLER-HAMMER #DG100N6 -(1)BRYANT# 1 P Ground/Neutral Kit; 60-100A General Duty(DG) Load Center; 125A25A,, 1 120/240V, NEMA 3R -(1)CUTLER-HAMMER #DS16FK -(1)CUTLER-HAMMER#BR220 Class R Fuse Kit Breaker, 20A/2P, 2 Spaces -(2)FERRAZ SHAWMUT#1R6OR PV BACKFEED OCP -(1)CUTLER-HAMMER#BR235 Fuse; 60A, 250V, Class RK5 Breaker; 35A/2P, 2 Spaces SSC-SUPPLY SIDE CONNECTION. DISCONNECTING MEANS SHALL BE SUITABLE B 1-(1)CUTLER-HAMMER #DG222URB Disconnect; 60A, 240Vac, Non-Fusible, NEMA 3R AS SERVICE EQUIPMENT AND SHALL BE RATED PER NEC. -(1)CUTLER-HAMMER /DG100NB Ground/Neutral Kit; 60-100A, General Duty(DG) (1)AWG#6, THWN-2, Black C 1-0)uuui&N #B-Line Meter socket 1111 (2)AWG#10, PV WIRE Black Voc* =338.27VDC Isc =$.92 ADC O L �(1)AWG 116, THWN-2, Red Meter Socket 125A, 4-14AWG, Ring Type LLL I -(1)AW CAP; B-Line Meter Socket Accessory 1 (1)AWG#6, Stranded Bare Copper EGC Vmp =244 VDC Imp=8.36 ADC (1)AWG 6,THWN-2,White NEUTRAL Vmp =240 VAC Imp=44 AAC -(1)Milbank J CL200D /Itron CIS 666 (1)Conduit Kit; 3/4" EMT THWN-2, Green EGC GEC 1)Conduit Kit; 3 4 EMT Solid-State Single-Phase Meter; Digital(1)Conduit Kit; 3/e EMT (2 AWG 0, PV 1MRE Black Voc* =338.27VDC Isc =8.92 ADC (1)AWG#10, THWN-2, Black (�' (1)AWG#6, THWN-2, Black C LE 2 I�(1)AWG#6, Stranded Bare Copper EGC Vmp =244 VDC Imp=8.36 ADC 8O (1)AWG#10, THWN-2, Red L=L 1 Conduit Kit; 3 4 EMT O (1)AWG#6, THWN-2, Red ( / ���LLL (1)AWG#6, THWN-2, White NEUTRAL Vmp =240 VAC Imp=44 MC (1)AWG#10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=16 MC -(2)AWG 0, PV WIRE, Black Voc* =591.98 VDC Isc =8.92 ADC Solid Bare.Co er GEC 1 Conduit Ki 3 4 EMT , , , . , . . . . -(1 AWG#8,.TH.WN-2,.Green, . . EGC/GEC._(1)Conduit Kit;•3 4•EMT °D 1 AWGCopper EGC Vmp 427 VDC Im -(1)AWG 1)6. Copper. . . . . . . . -(.) . . . . . .t;. ./7. . . . /" 3 5-( ) #6, Stranded Bore = Imp=8.36 ADC O6 � (1)AWG#8, 1HWM-Y,Black -(1)Conduit Kit; 3/4"EMT liE(1)AWG;8, THWN-2, RedVoc* = L (1)AWG#10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=28 MC (1)AWG#6, tr WIRE, Black 591.987VDC Iscm =8.92 ADC THWN-2, Green EGC GEC (1)AWG#6, Stranded Bare Copper EGC Vmp =427 VDC Imp=8.36 ADC (1)AWG#8 / • (1)Conduit Kit: 3/4"EMT J B-9722237 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL- THE INFORMATION USED FORHETHN JOB NUMBER: ;,,ei. 1 e....._ CONTAINED SHALL NOT BE USED THE BURNS, MICHAEL BURNS RESIDENCE Aaron Banks �_ . BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: 1 4" NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 13605 SW GARRETT CT 11.22 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULESTIGARD, OR 97223 ORGANIZATION, EXCEPT IN CONNECTION WITH3055 Clearview Way THE SALE AND USE OF THE RESPECTIVE (44) TRINA SOLAR # TSM-255PA05.18 PAGE"AME SHEET: REV DATE San Mateo,CA 94402 )638-1029 PERMISSION PS SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN 'N 5037899343 PV 5 10/27/2014 (888)soL-aTY((765-2489)T:(650)638-1028 �www.sdarcclty.cam Multiple Inverters THREE LINE DIAGRAM ELECTRICAL CALCULATIONSModule: 16 TRINA SOLAR#TSM255 ZEP 232.2 Inv Power WPTC Voltage Drop Calculations Version 5.8.0 Inverter 1: 1 ABB PVI 3.6 S AFCI 0.96 3840 3566.59 Vdrop= Imp) * (2*Length)*(Resistance) / (Vmp) Module: 28 TRINA SOLAR#TSM-255 ZEP 232.2 Imp(A) Max.Length(ft) Wire Inverter 2: 1 ABB PVI-6000-S AFCI 0.965 6000 6274.044 String: 8.36 70 AWG_10 at Max Ave Hi:87 deg F Module: Vdrop= (8.36 * 140 *0.00124Ohms) / 200.9828 0.72 Inverter 3: Branch: 8.36 I 50 I AWG_10 at Max Ave Hi:87 deg F Module: Vdrop= (8.36 * 100 *0.001240hms) / 200.9828 0.52 Inverter 4: Total voltage drop in DC conductors= 1.24 Inverter: 8.36 I 10 I AWG_10 I at 240V Vdrop= (8.36 *20 *0.0012 Ohms) / 240 V 0.0836 Total: 44 Modules Total Inv Pwr: 9840 9840.64 PTC Combined: 16.72 25 I AWG_6 at 240V Photovoltaic Module Electrical Specifications: Total STC: 11220 Vdrop= ( 16.72 *50 0.00049 Ohms) / 240 V 0.170683333333333 Voc: 37.7 V deg F deg C Vmp: 30.5 V Record Low Temp: 8 -13 Total voltage drop in AC conductors= 0.25 Isc: 8.92 A Max Average Hi Temp: 87 31 Total voltage drop in AC and DC conductors= 1.49 • Imp: 8.36 A Record Hi Temp: 96 36 Tvoc: -0.12064 V/deg C Tisc: 4.1924 mA/deg C String Type A and 2 Combined Strings Type A Voc Correction Method: Manuf Tvoc data Branch Circuit Type A 1 way wire length: 50 Voc Correction Factor: ABB PVI-3.6-S AFCI 1 strings per branch 1 1 strings per branch 2 8 TRINA SOLAR#TSM-255 ZEP Inverter Min Vdc Input: 120 8 modules per series string 8 modules per series string Voc= 301.6 Min Vmp at Max Temp: 200.98 Voc= 301.6 V Voc= 301.6 V Max Voc at Min Temp: 338.27 Vmp= 244 Vmp= 244 V Vmp= 244 V Inverter Max Vdc Input: 600 Isc= 8.92 Isc= 8.92 A Isc= 8.92 A Max String Size: 14 Imp= 8.36 1-way wire length: 70 Imp= 8.36 A Imp= 8.36 A Icont= 11.15 Art 690.8(A)(1) Icont= 11.15 A Icont= 11.15 A Art 690.8(A)(1) 1.a Conductor: AWG_10 PV Wire 2.a Conductor 1: AWG_10 Conductor 2: AWG_10 Icont*1.25=(Amps) 13.94 Conductor 1 Conductor 2 30 deg C ampacity= 40 Icont*1.25=(Amps) 13.94 13.94 1.b Icont=(Amps) 11.15 30 deg C ampacity= 40 40 Start ampacity 40 2.b Icont=(Amps) 11.15 11.15 Temperature derate(%=F) 0.76 Start ampacity 40 40 Conduit fill derate(%=#) 1 Temperature derate(%=F) 0.76 0.76 Derated ampacity 30.4 Conduit fill derate(%=#) 0.8 0.8 1.c Derated ampacity 24.32 24.32 Icont*1.25=(Amps) 13.94 2.c Term 1 Term 2 Ampacity 40 . Temp table 75degC 75degC Icont*1.25=(Amps) 13.94 13.94 1.d Icont*1.25=(Amps) 13.94 Ampacity 35 35 OCP Size= 15 Inverter Type A Output 2.d OCP Size= 15 15 ABB PVI-3.6-S AFCI 1 way wire length: 10 ft Combined Inverter Output Icont= 16 A Art 690.8(A)(1) Service Voltage= 3.a Icont*1.25=(Amps) 20 Art 690.8(B)(1) Total Inverter Power= 1 way wire length= 25 OCP Size= 20 Art 240.6(A) Icont=#of inverters*max inverter current Art 690.8(A)(1) 3.b Conductor: AWG_10 THWN-2 at 90 deg C:Table 310.16 Icont=(Amps) Icont*1.25=(Amps) 20 4.a Icont*1.25=(Amps) 55 Art 690.8(B)(1) 30 deg C ampacity= 40 OCP size= 55 Art 240.6(A) 3.c Icont=(Amps) 16 4.b Conductor: AWG_6 THWN-2 at 90 deg C:Table 310.16 Start ampacity 40 Icont*1.25=(Amps) 55 Temperature derate(%=F) 0.91 30 deg C ampacity= 75 Conduit fill derate(%=#) 1 4.c Icont=(Amps) 44 Derated ampacity 36.4 Start ampacity 3.d _ 75 3.d Icont*1.25=(Amps) 20 Temperature derate(/a=F) 0.91 Ampacity 35 Conduit fill derate(%=#) 1 Derated ampacity 68.25 4.d Icont*1.25=(Amps) 55 Ampacity 65 J B-9722237 00 PREMISE OWNER: DESCI8P11ON: DESIGN: CONFIDENTIALCONTAINED - THE INFORMATION HEREIN JOB NUMBER: ;,,SolarCity. CONTAINED SHALL NOT BE USED FOR THE BURNS, MICHAEL BURNS RESIDENCE Aaron Banks . , BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �I NOR SHALL IT BE DISCLOSED IN WHOLE OR IN CompMount Type C 13605 SW GARRETT CT 11.22 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: TIGARD, OR 97223 ORGANIZATION, EXCEPT IN CONNECTION MATH 3055 gearview Way THE SALE AND USE OF THE RESPECTIVE (44) TRINA SOLAR # TSM-255PA05.18 PACE NAME. SHEET: REV: DATE: San Mateo,CA 94402 PER IMSSIONOLARCITY EOFIS ENT,OLARCITY INC.T THE WRITTEN INVERTER: 5037899343 PV 6 10/27/2014 (888T:(650) -SSot-CTTY((76258-2489)�w)wwsolarcitycom Multiple Inverters ELECTRICAL CALCULATIONS Label Location: Label Location: Label Location: CAUTION: SOLAR CIRCUIT (C)(IC)(CB) MAXIMUM AC _ A (AC) (P01) CAUTION (P01) Per Code: OPERATING CURRENT Per Code: DUAL POWER SOURCE Per Code: IFC 605.11.1.4 MAXIMUM AC - v NEC 690.54 SECOND SOURCE IS NEC 690.64.6.4 OPERATING VOLTAGE PHOTOVOLTAIC SYSTEM Label Location: PHOTOVOLTAIC DC (DC)(INV) DISCONNECT Per Code: NEC 690.14.C.2 Label Location: Label Location: PV SYSTEM (AC) WARNING (DC) (INV) DISCONNECT FOR Per Code: UTILITY OPERATION ELECTRIC SHOCK HAZARD NEC 690.35(F) Label Location: THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE TO BE USED WHEN MAXIMUM POWER- A (DC)(INV) UNGROUNDED AND POINT CURRENT(Imp) Per Code: MAY BE ENERGIZED INVERTER IS MAXIMUM POWER- UNGROUNDED NEC 690.53 UNGROUNDED POINT VOLTAGE(Vmp) MAXIMUM SYSTEMv Label Location: VOLTAGE(Voc) WARNING (AC)(POI) SHORT-CIRCUIT Per Code: CURRENT(Isc) A ELECTRIC SHOCK HAZARD NEC 690.17(4) DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION j Label Location: WARNING (DC)(CB) Per Code: ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS NEC 690.17(4) Label Location: TERMINALS ON BOTH LINE AND WARNING (P01) LOAD SIDES MAY BE ENERGIZED Per Code: IN THE OPEN POSITION INVERTER OUTPUT DC VOLTAGE IS CONNECTION NEC 690.64.6.7 ALWAYS PRESENT WHEN DO NOT RELOCATE SOLAR MODULES ARE THIS OVERCURRENT EXPOSED TO SUNLIGHT DEVICE Label Location: Label Location: WARNING (DC)(INV) PHOTOVOLTAIC POINT OF (P01) Per Code: INTERCONNECTION Per Code: ELECTRIC SHOCK HAZARD NEC 690.5(C) WARNING: ELECTRIC SHOCK NEC 690.17.4; NEC 690.54 IF A GROUND FAULT IS INDICATED HAZARD.DO NOT TOUCH NORMALLY GROUNDED TERMINALS.TERMINALS ON CONDUCTORS MAY BE BOTH THE LINE AND LOAD SIDE UNGROUNDED AND ENERGIZED MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER. PV POWER SOURCE Label Location: MAXIMUM AC _ A OPERATING CURRENT (AC): AC Disconnect PHOTOVOLTAIC AC (AC) (P01) MAXIMUM AC v (C): Conduit DISCONNECT Per Code: OPERATING VOLTAGE (CB): Combiner Box NEC 690.14.C.2 (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit Label Location: (INV): Inverter With Integrated DC Disconnect CAUTION (D) (P01) (LC): Load Center PHOTOVOLTAIC SYSTEM Per Code: (M): Utility Meter CIRCUIT IS BACKFED NEC 690.64.6.4 (P01): Point of Interconnection CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR v0111I THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED ������� San30Mateo,i CAw Way - IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, ' ■ 94402 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE Sc - OR Label Set p-":ip�S�I ��ty T:(650)638-1028 F:(650)638-1029 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. (888)-SOL-CITY(765-2489)www.solarcity.com ZS Comp Edge Zone Calculations 1 of 49 ZS Comp Edge Zone Calculations 2 of 4 Zep S o to r 5/28/13 Zep S o l a r 5/28/13 This set of calculations is intended to show that ZS Comp has sufficient strength to allow for attachment Down Force Spacing spacings of at least 48"in Edge Zones whether the modules are orientated in landscape or portrait.The down force spacing= Allowable Down Force Load calculations will vary the design variables to account for the worst case for each failure mode that is being module width x design load checked. Wind Down Calculations All variable the same as above except for roof pitch General Design Information: Roof Pitch Module Size: 39"x 65" Basic Wind Speed= 95 mph 14 30 45 System Weight= 3 psf Ground Snow Load= 30 psf GCN landscape= 0.5 0.9 0.9 GCN portrait= 0.4 0.9 0.9 Comp Mount Allowable Loads Uplift= 656 lbs design load landscape= 9.62 17.32 17.32 psf Lateral= 436 lbs design load portrait= 7.70 17.32 17.32 psf Down Force= 1147 lbs - 'R o 0,I1 note:use 10 psf minimum 4w4wppp.-- Snow Calculations Attachment Spacing Calculations 85818 AA To account for unbalanced snow loads,ground snow loads will be used for roof pitches 30 degrees and Uplift Spacing OREGON Q lower.Per section 7.6.1 of ASCE 7-10 unbalanced snow loads do not need to be considered for slopes z,,ti 5 above 30 degrees. Allowable Uplift Load FRfMro , cs, uplif t spacing= module length or width x design load EXPIRES 12/31/14 Ground Snow Load= 30 psf Wind Uplift Calculations FOR PAGES 1-4 Roof Pitch ASCE 7-05 Method 2 14 30 Design Snow Load 29.11 25.98 psf p=ghGCN qh=0.00256 K,K, Kd V2 I (snow load spread over the length of the rafter) Basic Wind Speed= 95 mph Down Force Load Roof Pitch Exposure= C Roof Zone= Edge Zone Combinations: 14 30 Importance Factor= 1.0 K,= 0.98 from Table 6-3 D+S= 31.16 25.10 psf Gable/Hip Roof K,= 1.0 per 6.5.7.2 D+W= 12.91 19.92 psf /orst Case Roof Pitch= 14 degrees Kd= 0.85 from Table 6-4 D+0.75W+0.75S 31.59 32.46 psf Roof Height= 30 GCN landscape= -1.6 lscape effective area= 13.0 ft2 GCN portrait= -1.5 11471bs in 2 landscape down force spacing= -= 130" 39"x 32.46psf x 144 ft2 ortrait effective area= 21.7 ft / Plandscape= -30.79 psf qh= 19.25 psf Pportrait= -28.87 psf 11471bs in portrait down force spacing = 65"x 32.46psf x 144 ft2 = 78" Uplift Load Combination:0.6D+W(ASCE Section 2.4.1 equation 7) design load landscape= -29.05 psf design load portrait= -27.12 psf 656 lbs in landscape uplift spacing = =83" 39"x 29.05 psf x 144 ft2 656 lbs /in portrait uplift spacing = ft2 65"x 27.12 psf x 144 = 54" ZS Comp Edge Zone Calculations 3 of 4 ZS Comp Edge Zone Calculations 4 of 4 Zep Sota r 5/28/13 Zep So to r 5/28/13 Lateral Spacing Module Deflection Spacing The lateral force on the system increases as the pitch of the roof increases,but the amount of snow on landscape module spacing = -1.4545 x Maximum Uplift or Down Force Pressure+120.7273 the roof decreases for slopes greater than 30 degrees.With this in mind,the lateral force will be checked at 30 degrees with ground snow load and 45 degrees with sloped roof snow. portrait module spacing =-1.7917 x Maximum Uplift or Down Force Pressure+118.58 Allowable Lateral Load lateral spacing = module width x design load Maximum Uplift of Down Force Pressure= 32.46 psf Snow Calculations Ground Snow Load= 30 psf landscape module spacing= -1.4545 x 32.46 psf+120.7273 = 73" Ps=C5 pf Roof Pitch= 31 45 degrees pf=0.7CeCtlpg Ce= 0.9 C5= 0.71 0.45 Ct= 1.2 pf= 22.68 22.7 psf portrait module spacing = -1.7917 x 32.46 psf+118.58= 60" I= 1.0 p5= 16.1 10.2 psf Calculation Summary Calculated Edge Zone Spacing Roof Pitch Spacing Check Landscape Portrait 27 30 31 45 Uplift 83" 54" Design Snow Load 26.73 25.98 13.80 7.22 psf Down Force 130" 78" (snow load spread over the length of the rafter) 30° 27° 30° Lateral 74" 48" 45" -' Lateral Force Component Module Deflection 73" 60" Down Force Load Roof Pitch Combinations: 27 30 31 45 As can be seen in the table above,for Design Wind Speeds up to 95 mph and Ground Snow Loads up to 30 D+S= 13.50 14.49^ 8.65 7.22 psf psf with modules orientated in landscape,the system is strong enough to be installed at 72"on center in D+0.75W+0.755 10.46 11.24 6.88 5.95 psf the Edge Zone.When modules are installed in portrait,the spacing for edge zone installations can be 48" on center for most roof pitches.For roof pitches that are greater than 27°but less than 31°,the maximum 30 degree roof pitch attachment spacing is 45". 292lbs in landscape lateral spacing = 39"x 14.49 psf x 144 ft2 = 74" 292lbs in portrait lateral spacing= x 144 65"x 14.49 psf f=45" t2 Portrait spacing is less than 48".Try roof pitch of 27 degrees 292lbs in portrait lateral spacing = 65"x 13.50 psf x 144 ft2 =48" SolarCity SleekMountTM - Comp SolarCity SleekMountTM - Comp The SolarCity SleekMount hardware solution •Utilizes Zep Solar hardware and UL 1703 listed .- , " Installation Instructions is optimized to achieve superior strength and Zep CompatibleTM modules ' i aesthetics while minimizing roof disruption and Drill Pilot Hole of Proper Diameter for labor.The elimination of visible rail ends and •Interlock and grounding devices in system UL Fastener Size Per NDS Section 1.1.3.2 listed to UL 2703 mounting clamps, combined with the addition ; • of array trim and a lower profile all contribute •Interlock and Ground Zep ETL listed to UL 1703 Seal pilot hole with roofing sealant to a more visuallyappealing system.SleekMount as"Grounding and Bonding System" pp g y Insert Comp Mount flashing under upper utilizes Zep CompatibleTM modules with •Ground Zep UL and ETL listed to UL 467 as layer of shingle strengthened frames that attach directly to grounding device Zep Solar standoffs, effectively eliminating the Place Comp Mount centered need for rail and reducing the number of •Painted galvanized waterproof flashing upon flashing standoffs required. In addition, composition •Anodized components for corrosion resistance Install lag pursuant to NDS Section 11.1.3 shingles are not required to be cut for this \11111111111 • with sealing washer. system,allowing for minimal roof disturbance. •Applicable for vent spanning functions Secure Leveling Foot to the Comp Mount using machine Screw Place module c� • Components � _ • 5/16"Machine Screw • Leveling Foot '•� Lag Screw c*" • Comp Mount Comp Mount Flashing o `\ '7 1\11.FX:11111 .`m\I b . Q4�Mvp>ip� „IF s �SolarCity® January 2013 q�/ (17) 0 LISTED - ;''SolarCityo January 2013 DMPP TSM-PA05.1 TRINAMOUNT H WITH THE UNIVERSAL MODULE Mono Multi Solutions DIMENSIONSOFPVMODULETSM-PA05.18 ELECTRICAL DATA:CSTC TSM-240 TSM-245 TSM-250 TSM-255 TSM-260 PA05.18 PA05.18 PA05.18 PA05.18 : PA05.18 941mm Peak Power Watts-Pnnx(Wp) 240 245 250 255 260 Power Output Tolerance-Pun,(%) 0/+3 0/+3 01+3 01+3 -'0/+3 JUNCTX6N w Maximum Power Voltage-Vrve(V) 29.7 30.2 30.3 30.5 30.7 0 BOX Maximum Power Current-Iv/Hi(A) : 8.10 8.13' 8.27 8.36 8.47 NAMEPLATE Open Circuit Voltage-Voc(V) 37.3 37.5 37.6 37.7 37.9 INSTALLING HOLE Short Circuit Current-Isc(A) 8.62 8.68 8.85 8.92 9.00 ISM PA05 .1 8 ,:,.., il Module Efficiency nrs(%) 14.7 15.0 '. 15.3 '.. 15.6 15.9 THE TRINAMOUNT MODULE 3 so STC:Irradiance 1000 W/m',Cell Temperature 25°C,Air Mass AMI.5 according to EN 60904-3. Average efficiency reduction of 4.5%at 200 W/m'according to EN 60904-1. E 0 0 3 m 3 ELECTRICAL DATA @ NOCT TSM-240 TSM-245 TSM-250 TSM-255 TSM-260 0 r PA05.18 PA05.18 PA05.18 PA05.18 PA05.18 Maximum Power-Peer(Wp) 174 178 181 184 188 Maximum Power Voltage-we(V) 26.6 26.8 27.0 27.2 27.4 • MULTICRYSTALLINE MODULE rersroOmursvnvsr A A Maximum Power CurrenT-IMPP(A) 6.55 6.64 6.70 6.77 6.86 WITH TRINAMOUNT nn DRAIN Open Circuit Voltage(V)-Voc(V) 34.1 34.2 34.3' 34.4 34.6 7 Short Circuit Current(A)-Isc(A) 7.04 7.10 7.25 7.31 7.37 812mm 180 I NOCT:Irradiance 01 800 W/m',Ambient Temperature 20°C,Wind Speed I m/s. 24{0-260W Back View POWER OUTPUT RANGEmi. DATA Our most versitile product 1 t1 ® COmpatlble wl!-h all major BO$components acid system - Solar cells Multicrystalline 156 x 156 mm(6 inches) designs Cell orientation 60cells(6e10),.:. • Module dimensions 1650•992 x 40 mm(64.95 x 39.05 x 1.57 inches) � v } __._. _�_ _ _ __�._�_____. Weight 18.6 kg(41.0 lbs) MAXIMUM EFFICIENCY Glass High transparency solar glass 3.2 mm(0.13 inches) Backsheet i White . . One of the industry's most trusted modules ° Frame Black Anodized Aluminium Alloy with Trinamount Groove ttisa Over 2 OW sold across all major global markets • J-Box IP"65 or IP 67 rated '. �I�3trI • Field proven performance I-V CURVES OF PV MODULE ISM-245 PA05.180 MUl1 Cables Photovoltaic Technology (0.006 ) .. cable 4.0 mm' inches2), 1 ' ie.00 1100 mm(43.3 inches) OWER OUTPUT,GUARANTE E 9. I000W/m10 Connector ©rjg nal MC4 ^7.0 800W/m% --_ -__ ,. __- Highly reliable due to stringent quality control m 5m - _-__ "ik_____ As a leading global manufacturer • Over 30 in-house tests (UV,TC,HF,and many more) s 4.0 400W/rn TEMPERATURE RATINGS MAXIMUM RATINGS of next generation photovoltaic • In-house testing goes well beyong certification requirements 300_200W/m' _ Nominal Operating Cell 45°C(±2°C) Operational Temperature as-+85°C products,we believe close �°°._.._ _ ... AM_ I° `_ "'""` _ Temperature(NOCT) cooperation with our partners Maximum System 100oVDC(IEC)/' s critical to success. With local 00.E o°° 2000 bom Temperature Coefficient of Proen, -0.43%1°C Voltage 600V DC(UL) presence around the globe,Trina is Temperature Coefficient of Voc -0.32551°C Max Series Fuse Rating I5A able to provide exceptional service voltage(v) to each customer in each marketTemperature Coefficient of Isc 0.047551°C and supplement our innovative, „v Certified to withstand challenging environmental reliable products with the backing conditions of Irina as a strong,bankablei • 130 km/hr wind load (2400 Pa) WARRANTY partner. We committed • 900 kg snow load per module (5400 Pa) 10 year Product Workmanship Warranty to building strategic,mutually beneficial collaboration with 25 year Linear Power Warranty Installers,developers,distributors (Please refer to product warranty for details) m and other partners as the backbone of our shared success in CERTIFICATION F driving Smart Energy Together. LINEAR PERFORMANCE WARRANTY s.1 RI \�1VJ PACKAGING CONFIGURATION 10 Year Product Warranty•25 Year Linear Power Warranty "- \ cool . .c��US Modules per box:24 pieces Trina Solar Limited F � ti www.frinasolar.com • - '" d l00% Modules per 40'container 672 feces a pddifion ISO % (E 0 vv`2YCLE at value b , 0 90% `'1�. -*-`"E 4f"h W y r arty Trina $q/a!"'S linear Warranf1, CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. ot4P4Tje sl` `f' '( y 3 t''tT r .. 02013 Trina Solar Limited.All rights reserved.Specifications included in this datasheet are subject to WQ !� rin'soIar 80% fL 5 3 E QTY �,��5®ICid" change without notice. Smart Energy Together 4 a ...• Smart Energy Together lA e Years 5 10 15 20 25 CpMPpT INTrina Solar Additional highlights: — RS-485 communication interface (for connection to laptop or data (7 ':, !' .'' ' -.).. ;' I_t_(_: logger). ��v ; �� �i v�.�,' � �s EY i �_ � � I t� — Integrated Arc Fault Detection and Interruption(-A Version). tl ; . Technical data and types i.," Type code PVI-5000-OUTD-US PVI-6000-OUTD-US __ InpuYside - Nominal output power 5000W 6000W Maximum output power 5000W 6000W Rated grid AC voltage 208V 240V 277V 208V 240V 277V a,. Input side(PC) Number of independent MPPT channels 2 Maximum usable power for each channel 4000W 1"0 Absolute maximum voltage(Vmax) 600V Start-up voltage(Vstart) 200V(adj.120-350) € Full power MPPT voltage range 200-530V Operating MPPT voltage range 0.7 x Vstart-580V ` Maximum current(Idcmax)for both MPPT in parallel 36A Maximum usable current per channel 22A r Number of wire landing terminals per channel 2 Pairs ` Array wiring termination Terminal block,pressure clamp,AWG16-AWG6 " Output:side.(AC) Grid connection type 10/2W Split 0/3W 10/2W 10/2W Split-0/3W 10/2W Adjustable voltage range(Vmin-Vmax) 183V-228V 221 V-264V 244V-304V 183V-228V 211V-264V 244V-304V Grid frequency 60Hz Adjustable grid frequency range 57-60.5Hz Maximum current(Iw°,�„)AAMs_.. _._.._ _._27A666„ : 23Ams 20A s - 30A„s28Am6„s ...24Ams......... Designed for residential and small The wide input voltage range Highlights: Power factor >0.995 g Total harmonic distortion at rated power <2% commercial PV installations,this makes the inverter suitable to low _ Single phase and split phase output36 25 A k/ 36.5 A / 31.75 A k/ 36.25 A k/ 36.5 A k/ 31.75 A k/ Contributory fault current' power installations with reduced ___..... 25.63AgMs 25.81AaMs 22.45A'M5 25.63Als 25.81AaMs 22.45As__ inverter fills a specific niche in the grid connection. Grid wiring termination type Terminal block,pressure clamp,AWG14 AWG4 ABB product line to cater for those string size. - Wide input range for increased ttrput is The transformerless operation offers Reversepolarityprotection producing between stringing flexibility, Yes high performance efficiencies of up to Over voltage protection type Varistor,2 for each channel 5kW and 20kW. o The high speed and precise MPPT PV array ground fault detection Pre startup Riso and Dynamic GFDI(requires floating arrays) 97.1/o. algorithm offers real time power quyt Free remote monitoring capability tracking inverter includes dual input and improved energy Anti-islanding protection Meets UL 1741/IEEE1547 requirements Meets UL 1741/IEEE1547 requirements section to process two strings with available with every installation.This harvesting. Over voltage protection type Varistor,2(L,-I,/L,-G) Varistor,2(L,-L2/L, G) enables homeowners to view their Maximum AC OCPD Rating 35A 30A 25A 40A 35A 30A independent MPPT. - Outdoor NEMA 4X rated enclosure €frfeienvry energyproduction and offers installers The high speed and precise MPPTitll for unrestricted use under any Maximum efficiency 97.1% a proactive and economic way of CEC efficiency 96% 96.5% 96.5% 96% 96.5% 96.5 algorithm offers real-time power environmental conditions. user interface Graphic display Graphic display tracking and energy harvesting. maintaining and troubleshooting the - Integrated DC disconnect switch C�perating8etfvrmat�ae s Flat efficiencystem.curves ensure high y in compliance with international Stand-by consumption <sw.. <8WaMs Night time consumption <0.6w,,, <0 6W efficiency at all output levels ensuring Standards(-S Version). �M< ctirnmuriid tjcsn . .. consistent and stable performance User-interface 16 characters x 2 lines LCD display across the entire input voltage and Remote monitoring(1xRS485 incl.) VSN700 Data Logger(opt) output power range. Wired local monitoring(1 xRS485 incl.) PVI USB RS485_232(opt.) �nvirciri€rkentat" This outdoor inverter has been -13°F to+140°F(-25°C to+69°C)with Ambient air operating temperature range -13°F to+140°F(25°C to+60°C) designed as a completely sealed unit to derating Ambient air storage temperature range -40°F to+176°F(-40°C to+80°C) -40°F to+176°F above 122°F(50°C) 176°F(-40°C to+80°C) withstand the harshest environmental Relative humidity 0-100%RH condensing 0-100%RH condensing conditions. Acoustic noise emission level <50 db(A)©1m <50 db(A)@1 m 11 ,! ,! Maximum operating altitutde without derating 6560 ft(2000 m) 6560 ft(2000 m) Power and productivity 2.Inverter can apply that much current-Breaker will open for a better world"' T %UW P 2 ABB Solar Inverters I Product flyer for PVI-5000/6000-TL-OUTD Additional highlights: Solar inverters ' — RS-485 communication interface (for connection to laptop or data logger). fl\11 _ ' f / t r, 1) .TI (I I ] il ,. ; , ... .. ..,r ._.. , , ,_ '. . i_✓ — Integrated Arc Fault Detection and r Interruption(-A Version). 1 Technical data and types ,,.. ' Type code PVI-3.11 OUTD-US PVI 3.6-OUTD-US PVI-3.8-OUTD-US PVI-4.2-OUTD-US ` ASS Mechanical specifications ^v ,: _ 3300_ Nominal output power 3000W - 3600W W 3800W 4200W • • 3000 33001 3300' 3600 4000' 4000 3300 4200' ---4200' 4200 4600' 4600' �• Maximum output power wattage ' W W W W W W W W W W W W Rated grid AC voltage 208V • 240V 277V 208V 240V 277V 208V 240V 277V 208V 240V 277V Input rside(PO) " Number of independent MPPT channels 2 2 2 2 -" Maximum usable power for each channel 2000W 3000W 3000W 3000W Absolute maximum voltage(Vmax) 600V Start-up voltage(Vstart) --- ------ 200V(adj.120-350V) -------- - ^ , Full power MPPT voltage range 160-530V - 120-530V 140-530V 140-530V Operating MPPT voltage range 0.7 x Vstart (580V(>=90V) Maximum current(Idcmax)for both MPPT in ---- 20A 32A 32A 32A parallel t�; Maximum usable current per channel ------ 10A16A -------- 16A 16A ---- Maximum short circuit current limit per 12 5A 20.0A 20 OA 20 OA channel Number of wire landing terminals per channel 2 pairs „rmgxw,.. Array wiring termination Terminal block,pressure clamp,AWG10-AWG4 Output l °' hn � ,r 10/ Split- 10/ 10/ Split- 10/ 10/ Split- 10/ 10/ . Split- 10/ Grid connection type 2W 0/3W 2W 2W 0/3W 2W 2W 0/3W 2W 2W 0/3W 2W___, ...�� �.,- Adjustable voltage range(Vmin-Vmax)(V) 183 211- 244 183- 211- 244- 183- 211- 244 183- 211- 244- 228V 264V 304V 228V 264V 304V 228V 264V 304V 228V 264V 304V Grid frequency 60Hz ' Adjustable grid frequency range 57-60.5Hz Maximum current(lam„) , 14.5 14.5 12.0 17.2 16.0 16.0 ' 16.0 16.0 16.0 20.0 20.0 20.0 _. __...... •.....Aaws AH„s Aa s L Aare :....A„ Aa„.F • AHms._. A„,„ !....mws, .....mans _..A„„ A„,„„ .. Power factor >0.995 Total harmonic distortion at rated power - <2 This family of single-phase string The high-speed MPPT offers real- Highlights: Grid wiring termination type Terminal block,Pressure clamp,AWG10-AWG4 inverters complements the typical time power tracking and improved — Single phase and split phase output tapufiproteotion°devices ” '" Reverse polarity protection Yes number of rooftop solar panels energy harvesting, grid connection. Over-voltage protection type Varistor,2 for each channel enablinghome-owners toget the most The flat efficiencycurve ensures high — Wide input range for increased PV array g p g ground fault detection Pre start-up Riso and Dynamic GFDI(requires floating arrays) efficient energy harvesting for the size efficiency at all output levels allowing stringing flexibility. Outputi;ptofection devices ' ' of the property. a consistent and stable performance — The high speed and precise MPPT Anti-islanding protection Meets UL 1741/IEEE1547 requirements N Over-voltage protection type Varistor,2(L, 4/L G) ,+ A across the entire input voltage and algorithm offers real time power Maximum AC OCPD Rating 20An„, 20A„„, 15A„„, 25Aa„° 20A„„, 20Ap„, 20A,,,, 20A„„„ 20Aa.,` 25A„,, 25A„„, 25A„„, This inverter offers a dual input output power range. tracking and improved energy ° s Maximum efficiency 96.9% 97% 97% 97% section that processes two strings The transformerless operation gives the harvesting. CEO efficiency 96% with independent Multiple Power Point highest efficiency of up to 97.0%. — Outdoor NEMA 4X rated enclosure ftpetaftng'perfornrartee” 1 Tracking(MPPT). The wide input voltage range makes for unrestricted use under any Night time consumption <0.6Wa„, • This is especially useful for rooftop the inverter suitable to low power environmental conditions. Stand-by consumption <aw„„ Gtsrruni#nit�#3titt. .:, . . installations with two different installations with reduced string size. — Integrated DC disconnect switch User interface 16 characters x 2 lines LCD display orientations from two sub-arrays This rugged outdoor inverter has been in compliance with international Remote monitoring(1xRS485 incl.) VSN700 Data Logger 99 p (opt) x uirtyftt ental '. { oriented in different directions.(For designed to be a completely sealed Standards(-S Version). a Ambient air operating temperature range -13°F to+140°F with derating above 122°F(50°C) example:East and West) unit able to withstand the harshest Ambient air storage temperature range -40°F to+176°F(40°C to+80°C) The dual input sections with environmental conditions. Relative humidity 0-100%RH condensing Acoustic noise emission level <50 db(A)@1m --- independent MPPT enable a more Maximum operating altitutde without derating 6560 ft(2000 m) optimal energy harvesting condition. Power and productivity ,® �� ,� 1.Capability enabled at nominal AC voltage and with sufficient DC power available. for a better world'” P'91111111111 2 ABB Solar Inverters I Product flyer for PVI-3.0/3.6/3.8/4.2-TL-OUTD