Plans (67) on BULL '= MCNINIAfN t, Haggerty Solar _n CITY OTIVIGATill rIG : . • FOR CODS COMPLIANCE 1 15298 SW Greenridge P1 AP _rY f �g 1 JUL 2014 Tigard OR 97224 OTCs i `� g �. • K�►,y Coty gCIT�O£ - IGS} _D Permit r'"1 1 ``- f� (C)- - (4 Golf l sNINGt:a�' GiNEERING Addresu i5 ., _ A F u :e SCOPE OF WORK 8r, n [(47" - OFFICE COPY The project scope includes the installation of a grid-tied, Roof-mounted SW Durham Rd 3.3 kW SolarWorld PV module array in Tigard,WA. beipen t fl d KING az This installation consists of the roof-mounted array, CITY 1 SMA inverter,and related electrical metering and safety equipment. All equipment will be installed as required by applical codes ELECTRICAL NOTES and the local utility company. SHEET INDEX 1. A nationally recognized testing labratory shall list all equipment in compliance with ART,110.3 LEGEND ABBREVIATIONS PV 1 - COVER SHEET PV 2 - ELECTRICAL NOTES AND LABELS 2. Each ungrounded conductor of the multiwire PV 3 - PROPERTY PLAN ---- branch circuit will be identified by phase and system Inverter A AMPERE kW KILOWATT PV 4 - SITE PLAN per ART.210.5. AC ALTERNATING CURRENT OC ON CENTER BLDG BUILDING PL PROPERTY LINES PV 5 - ELEVATION Meter CONC CONCRETE PV PHOTOVOLTAIC PV 6- ATTACHMENT DETAIL 3. When a circuit may be energized in the open C COMBINER BOX SS STAINLESS STEEL PV 7 - RACKING PLAN position,a sign will be provided warning of the PV Module D DISTRIBUTION PANEL STC STANDARD TEST CONDITIONS PV 8 - ARRAY SPECIFICATIONS hazard per art.690.17. DC DC DIRECT CURRENT V VOLTS PV 9 - VOLTAGE DROP CALLS E3 DC disconnect EGC EQUIP GROUNDING CONDUCTOR Vmp VOLTAGE AT MAX POWER 4. DC conductors shall be run in metalic raceways or PV 10- ELECTRICAL DIAGRAM EMT ELECTRICAL METALIC TUBING Voc VOLTAGE AT OPEN CIRCUITenclosures to the first accessible DC disconnecting AC AC Disconnect GALV GALVANIZED W WATT PV 11 - MODULE CUT SHEET GEC GROUNDING ELECTRODE CONDUCTER means per article 690.31(E). P� PV 12- INVERTER CUT SHEET I ND GROUND CURRENT PV 13- MOUNTING SYSTEM CUT SHEET 5. All exposed metal parts(Module frames,rails, - Imp CURRENT AT MAX POWER PV 14- MATERIALS LIST boxes,ETC)shall be grounded be bonded and Isc SHORT CIRUIT CURRENT grounded at the main electrical panel. Contractor Information Project Information Energy Unlimited LLC Kelly and Jackie Haggerty PV 1- COVER SHEET EN E RGY 38888 Pioneer Blvd 15298 SW Greenridge PL UNLIMITED Sandy,OR 97055 Tigard, OR 97224 CCB#185705 g 6/3/2014 LABELS ELECTRICAL NOTES FOR NEW PHOTOVOLTAIC SYSTEM; 6,IF USED,ALL Vb1 REM JTS ARE TO BE INSTALLED DER LOCATION 6 THE CONNECTION 0 THE MODULE OF THIS PROPOSED GENERAL NOTES GRID TIE PHOTOVOLTAIC INVERTERS; REQUIREMENTS AND MANUFACTURERS SPECIFICATIONS BY A SOLAR ELECIR C SYSTEM SHALL BE SO ARRANGED THAT 1,THIS PROPOSED SOLAR ELECTRIC SYSTEM IS INTENDED TO OUALIrIEDicERTIrIEo PERSON,WIRCNUTS SHALL NOT DC USED RE'AOVAL OFA MODULE FROM THE DHCTONOLTAIC SOURCE 1.SYSTEM GROUNDING MEANS;THIS INVERTER IS INTENDED TO 0 ' ' r D"s on -oat OPERATE IN PARALLEL WITH POWER RECEIVED FROM THE ON DC CONDUCTORS. CIRCUIT DCES 401 INTERRUPT A GROUNDED CONDUCTOR 10 BE INSTALLED AS PART OF A PERMANENTLY GROUNDED I " 1 ' - ' ANOTH R PHOTOVOLTAIC SOURCE CINCUIT, SETS OF ELECTRICAL SYSTEM PER-HE NEC ANSENFPA 70,A GROUND UTILITY SERVICE PROVIDER, 7,FUSES AND WIRES SUBJECT TO TRANSFORMER INRUSH CONNECTION FOR THE TRANSFORMER AND INVERTER MUST BE CIONODULES INTERCONNECTED AS SYSTEMS RATED AT 50 VOLTS A.URRENT SHALL BE SIZED I RF I I ACCORDINGLY, INSTALLED AND CONNECTED TO THE UNIT AS DESCRIBED IN 2.THE INVERTER FOR THE PROPOSED SOLAR ELECTRIC CR LESS WTH OF PENT UT ICE SHAG DIODES ANC 1-AVINC A THE INSTALLATION MANUAL THE AC AND DC GROUND BUS VYMt�iIWEa'; :k SYSTEM SHALL BE IDENTIFIED AND LISTED AS A UTILITY R.AI11)[ MATFRIAI S SHAT I RF I I.STFD FnR iV DC SINGLEOVER CURRENT CEVICE SHAL BE CONSICEREQAS ABARS ARE CONNECTED TO THE MAIN INVERTER ENCLOSURE,A FI®TMINA" INTERACTIVE INVERTER FOR USE IN SOLAR PHOTOVOLTAIC SINGLE SOURCE CIRCU T. GROUND FAULT INTERRUPT FUSE IS PROVIDED BETWEEN Teri is oaPnd Lo4Ld ski.* SYSTEMS, 9 CONDUITS AND CONDUCTORS;ALL INTERCONNECT WuIRING NEGATIVE DC INPUT AND DC GROUND BUS BAR, THE GROUND in tle Olen Paofean. AND POWER CONI:YJCTORS INTERFACING THE UNIT MUST NE IN 7 GROUND NG SYSTEMCOMFONENFS SHALL 36 LISTED FOR FAULT FUSE IS MONITORED AND 1HE INVERTER IS A THIS SYSTEM IS INTENDED TO CONNECT TO THE EXISTING ACCORDANCE WITH THE NEC ANSINrPA 70 AND ANY THEIR PLRPCSE,INCLUDNG BLT NOT L M TEC 10 GROUND DISCONNECTED FROM THE GRID IN THE EVENT OF A GROUND FACILITY POWER SYSTEM AT ONE POINT,POINT OF COMMON APP,ICAPI F I OCA, CODES.I ARGF GAUGE WIRF 11 LIST RQD5.GROUNCING LUGS GROUNDNS CLAMFS EC`, FAULT, COUPLING(POCC). THIS CONNECTION SHALL BE IN CONFORM TO THE MINI MUM BEND RADIUS SPECIFIED IN THE SMAFZtr1IM{s'-Dual Plower Sou mos NEC,ARTICLE 300,3 1,KEEP ALL WIRE BUND_ES AWAY FROM g W ERE GROUND FAIL FRO'EC?ION I5 NOT PROVIDED 2.UTILITY SIDE ISOLATION TRANSFORMER:INVERTERS ARE 0 COMPLIANCE.WITH THE NEC ARTICLE 696,64"POINT OF among aaPUFCR I� ie spm ANY SHAH'tJt S IU RVUIU DAPo1ACit i0 WINE INSULA ION, EACH GROUNDING CONDUCTOR SHALL 3E SIZED TO TNCE'HE SUPPLIED WITH AN INTEGRAL CUSTOM HIGH EFFICIENCY CONNECTION", ALL CONDUCTORS SI 1OULD BE MADE Or COPPER AND RATEDISOLATION TRANSFORMER AS PART OF THE INVERTER FOR FO DEGREE C MININUM.FOR OUTDOOR INSTALLATIONS, NOVAE CALCULATED OPACITY,ER NEC F90,45(3) 0RATED OPERATING CURRENT: —A ASSEMBLY,THE OUTPUT TRANSFORMER IS USED FOR VOLTAGE 4.ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE ALL INTERCONNECT CONDUITS AND FITTINGS MUST BE NEMA-4 MATCHING TO UTILITY VOLTAGE APPLICATION,THIS OROVIDES CIRCUIT PROTECTION FOR TESTING AND ISOLATION. RATED AS REQUIRED BY THE NEC, A BALANCED,CURRENT SOURCING INVERTER AND ONLY RATED OPERATING VOLTAGE° MIV GROUND FAULT PROTECTION; OPERATES WITH THE PRESENCE OF A STABLE UTILITY VOLTAGE 5,ALL DISCONNECTS AND COMBINERS SHALL BE SECURED 10,CONNECTORS TO DC TORQUED PER DEVICE LISTING_OR MAXIMUM SYSTEM VOLTAGE: =IV FROM UNAUTHORIZED+UNQUALIFIED PERSONNEL BY LOCK OR MANUFACTURERS RECOWMENDATIONS. 1 PHOTOVOLTAIC INVERTERS SIiAL.BE EQUIPPED WID CC 3.INVERTER ENCLOSURE;INVERTERS ARE NDOOROUTD00R LOCATION GROUND FAULT PROTECTION TO REDUCE F RE HAZARDS. RATED,IEC GRADE,NEMA 3R.ALUMINUM CONSTRUCTION WITH FATED SHORT-CIRCUIT CURRENT:®A 11,ALL AC WIRING SHALL BE COPPER MIRE,TYPE THWNN-2 ENAMEL COATED PAINT ON ALL SURFACES,ALL REMOVABLE 6,ALL DISCONNECTS,COMBINERS,PULL SPLICE BOXES.AND RATED AT 90 DEGREE C.AND RATED FOR BOOP.OR APPROVED DISCONNECT NS MEANS; INTERNAL PANELS ARE COVERED WITH ENAMEL COATED PAINT ® ENCLOSURES SHALL BE LISTED FOR IT'S PURPOSE. EQUAL, ON ALL SURFACES,ALL SURFACES ARE TREATED WITH A Customer Owned Solar 1 MEANS SHALL BE PROVIDED HODISCONNECTALL CURRENT ZINC-RICH PRIMER AND THEN POWDER COATED TO INHIBIT 7, EQUIPMENT SHALL BE INSTALLED IN A SECURE AREA TZ.PROPERLY SUPPORT A_L EXPOSED PM SOURCE CIRCUITS 1 MEA CARRYING BE TOOOF THE PHOIOVOLTAC POWER CORROSION, Generator Output INVERTER PERFORMANCE MAY BE AFFECTED IF INSTALLED IN TO MAINTAIN THE INTEGRITY OF THE CONDUCTOR'S SOURCE FROM ALL OTHER CONDUCTORS IN THE BUILDING, INSULATION, 4.ENVIRONMENTAL CONDITIONS:INVERTERS ARE DESIGNED TO DIRECT SUNLIGHT, BE INSTALLED IN EITHER AN INDOOR OR OUTDOOR LOCATION, WIRING METHODS: GROUNDING; 2, THE DISCCNVECTNG MEANS SHALL NOT BE REQUIRED TO THE UNI'MUST BE ANCHORED TOA LEVEL CONCRETE FLOOR BE SUITABLE AS SERVICE EQVIPNENT AND SHALL BE RATED IN OR STEEL PLATFORM.ALLOWABLE OPERATING TEMPERATURE SEE ELECTRICAL DIAGRAM AND ELE CTRICA_DETAILS FOR ACCORDANCE WITH SECTION690.17. RANGE FOR THE UNITS ARE SPECIFIED BY THE ALL WIRING METHODS AND INSTALLATION PRACTICES SHALL MORE GROUNDING IN FORMATION. MANUFACTURER, CONFORM TO THE NATIONAL ELECTRICAL CODE(NEC),LOCAL 3 A SIMS E CISCONN_CT Na NEAN5 SF1ALLBE?ERMi`TED F02 STATE CODES.AND OTHER APPLICABLE LOCAL CODES 1,ONLY ONE CONNECTION TO DC CIRCUITS AND ONE THE COMBINED A C.OUTPUT OF ONE OR MORE NYERTERS IN CONNECTION TO AC CIRCUITS WILL BE USED FOR SYSTEM AN INTERACTIVE SYSTEM, 1,EXPOSED PV SOLAR PANEL WIRING WILL BE USE,2,90 GROUNDING{REFERENCED TO THE SAME POINT,,THIS WILL DEGREE C,WET RATED AND UV RESISTANT, ALL EXPOSED NORMA'I Y RE I OC.ATF0 AT THE INVERTER. REQUIRE)SAFETY SIGNS AND LABELS: CABLES,SUCH AS MODULE LEADS SHALL BE SECURED WITH 2.EQUIPMENT GROUNDING CONDUCTORS AND SYSTEM 1.REQUIRED SAFETY SIGNS AND LABELS SHALL BE MECHANICAL OR OTHER SUNLIGHT RESISTANT MEANS, GROUNDING CONDUCTORS WILL HAVE AS SHORT A DISTANCE PERMANENTLY ATTACHED BY ADHESIVE,OR OTHER MECHANICAL MEANS, LABELS SHALL COMPLY WITH ARTICLE 2.ALL GROUNDED CONDUCTORS SHALL BE WHITE OR GRAY 3,NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED 690 VI OF THE NEC OR OTHER APPLICABLE STATE AND LOCAL AND EQUIPMENT GROUNDING CONDUCTORS GREEN OR BARE, FOR PROPER GROUNDING;NOTING THAT TERMINAL LUGS CODES, SEE LABELS AND MARKING PAGE FOR MORE (NEC 200.61.LABEL COMBINER BOX WIRING RED FOR POSITIVE. BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE INFORMATION, WHITE FOR NEGATIVE AND GREEN FOR GROUND, INSULATED BECAUSE OF PAINT'FINISH, PAINTJFINIS-t AT POINT ELECTRICAL SAFETY FEATURES: 3.ALL FIELD WIRING THA IS NOT COLOR CODED SHALL BE OF CONTACT SHALL BE PROPERLY REMOVED, MARKED AT BOTH ENDS WITH PERMANENT WIRE MARKERS TO THE UNI'HAS ONLY ONE MODE OF OPERATION,LINE LINKAGE IDENTIFY POLARITY AND CIRCUIT IDENTIFICATION, 5,MODULES SHALL BE GROUNDED WITH EQUIPMENT MODE(GRID EXPORT MODE),THE OUTPUT VOLTAGES AND GROUNDING CONDUCTORS BONDED TO A LOCATION APPROVED CURRENTS ARE SINUSOIDAL WITH LOW TOTAL HARMONIC BY THE MANUFACTURER WITH A MEANS OF BONDING LISTED DISTORTION MEETING IEEE 5' 1952 HARMONIC STANDARDS. 4,CONDUIT TYPES USED IN THE PV INSTALLATION SHALL BE FOR THIS PURPOSE. APPROVED FOR THEIR SPECIFIC APPLICATION AND SUPPORTED THE ANTHSLANDING TRIP RIP TIME IS LESS THAN(2)SECONDS AS PROPERLY PER NEC, PER UL 1741 STANDARDS,THE INVERTER UNIT WILL AUTOMATICALLY SHUT DOWN WHEN THE LOSS OF GRID POWER 5,LONG STRAIGHT CONDUIT RUNS,100 FEET OR MORE,S-tALI IS DETECTED. HAVE EXPANSION FITTINGS,IF EXPOSED TO WEATHER. Contractor Information Project Information PV 2- ELECTRICAL NOTES Energy Unlimited LLC Kelly and Jackie Haggerty ENERGY 38888 Pioneer Blvd 15298 SW Greenridge PL AND LABELS UNLIMITED Sandy,0R 97055 CCB#185705 Tigard, OR 97224 6/3/2014 Site Plan Sheet Notes Scale: Not to scale 1. Dedicated PV System Meter 2. Distribution panel and N (2)SMA Inverters Warning Labels 1,2,3,4,5 3.Utility Meter 4. Warning sticker 4 5. Refer to PV 1 for warning 13 Pathfinder Placement labels 1 Location —...1;n1\ z TEC, N >. a7 A a) on 1. cu Existing System NEW SYSTEM 8 SW255 Solar Panels 12 SW275 Solar Panels Contractor Information Project Information Energy Unlimited LLC Kelly and Jackie Haggerty PV 4- SITE PLAN ENERGY 38888 Pioneer Blvd 15298 SW Greenridge PL UNLIMITED Sandy,0R 97055 Tigard, OR 97224 CCB#185705 g 6/3/2014 ELEVATION Scale: Not to Scale dpw solar rail and L-brackets 2 rows of 6 Solar Modules Modules>12" from ridge Quickmount PV mounting System (See Cut Sheet for details) 2"x 4"premanufactured ' trusses spaced at 24"OC 414.000111111100.0000••••e°00, 11%%1%1I% Composition Roofing 11 E� I Contractor Information Project Information Energy Unlimited LLC Kelly and Jackie Haggerty PV 5- ELEVATION ENERGY 38888 Pioneer Blvd 15298 SW Greenridge PL UNLIMITED Sandy,OR 97055 Tigard, OR 97224 CCB#185705 g 6/3/2014 ATTACHMENT DETAIL Scale' 3 = 1 (1:4) Rail spacing must be 33">=49 1/2" 111 Stainless Steel Lag bolt provided by viimanufacturer SolarWorld Solar Module .;' Standard Compostion roofing �\ I Solar Rail \\ \� \� Flashing provided by PV Quickmount �% . ,..... See product sheet for more detail IS '1 \ Contractor Information Project Information Energy Unlimited LLC Kelly and Jackie Haggerty PV 6- ATTACHMENT DETAIL EN E RGY 38888 Pioneer Blvd 15298 SW Greenridge PL UNLIMITED Sandy,OR 97055 Tigard, OR 97224 CCB#185705 g 6/3/2014 SECTION VIEW is ° • Scale: 1/4" : 1' (1:48) Plumbing Pipes East Facing Solar Roof co 55" / 394/2" / 42" \ / --2‘. 24" 1 48"� -- O �4" o e O e n b 48"tYP 1 �4" �r N �4 4s e o O 1 48"I O e e � 1 24" 7t Fr) 4S-O" /I. Contractor Information Project Information Energy Unlimited LLC Kelly and Jackie Haggerty PV 7- RACKING PLAN EN E RGY 38888 Pioneer Blvd 15298 SW Greenridge PL UNLIMITED Sandy,OR 97055 Tigard,CCB#185705 g 6/3/2014 • Design Location and Temperatures Module Specifications Lyltiw! ' tAS 21:'er.4VaxdseleectCoent.y4agta,ax1,4.pot ' gaily 2.Select A xdErn3ycrC.cechrnsiM.ivx�ieralc+rabsieriten rakaate Module Name SW 275 mono Temperature Data Source ASHRAE 2%High Temp 1 v Rated Power(STC) 275 W Country United_States v Module Voc 39.40 VDC State Oregon ► Module Vmp 31.00 VDC Weather Station PORTLAND/HILLSBORO ► Module Imp 8.94 ADC ZIP Code Reference 97224 1Module Isc 9.58 ADC Weather Information Solar ABC's ' Weather.com 1 Voc Correction(VC) -0.300% ASHRAE Extreme Low Temp -8.4'C Vmp Correction(WC) -a450% ASHRAE 2%High Temp 32.1'C Rated Power Tolerance(+I-%) +51-0 Average Summer Time High 27.1'C Series fuse rating 16 Adj.Module Voc @ ASHRAE Low Temp 43.35 VDC Equipment Selection Adj.Module Vmp @ ASHRAE 2%Nigh Temp 25.13 VDC Ad.Module Vmp @ ASHRAE Avg.High Temp 25.83 VDC Low Temp for Calculations -8.4'C High Temp for Calculations 32.1'C Average Summer Time High 27.1'C Inverter Specifications Roof,Rack or Pole mount? Roof 1 y Module Manufacturer SolarWorld ,► Inverter Name Module Model Number SW 275 mono `♦ SB3000TL-US @ 240 Inverter Manufacturer SMA America 1► Number of MPPT's Two Inverter Model Number SB3000TL-US @ 240 1► Maximum Power Point Tracking((PK) 175 Min. 480 Max. Maximum Input Voltage 600 VDC Maximum Input Current Per MPPT 15.00 ADC System Design Parameters Maximum Input Power 3,750 WDC Single MPPT Dual MDPT Minimum String Size 7 7 Maximum Output Current 15.00 AAC Maximum String Size 13 13 AC Overcurrent Protection 20 AAC Est.Maximum Strings in Parallel 31 Maximum Output Power 3,000 WAC Maximum Number of Modules 13 6 per MPPT CEC Weighted Efficiency 96.5% Array Design Options System Electrical Specifications MPPT Setup ( Single MPPT T I, Single MPPT - Single MPPT String Configuration: 1 x 12 Select String Size 12 Power Rating per MPPT(STC) 3,300 W Select Total Strings in Parallel 1 Adj.Array Vmp @ ASHRAE 2%High Temp 301.6 VDC Adj.Array Vmp @ ASHRAE Avg.High Temp 310.0 VDC Rated Isc For Specified Array 9.6 ADC Total Number of Modules 12 DC Disconnect Calculations: STC Rating of Array 3,300 WATTS Max.System Voc @ ASHRAE Low Temp 520.2 VDC Voltage @ Rated Max Power(Typ.Op.Vmp) 372.0 VDC Array will operate within the parameters of the selected inverter Maximum Short Circuit Current 120 ADC Current @ Maximum Power Point(Imp For array) 8.9 ADC Contractor Information Project Information Energy Unlimited LLC Kelly and Jackie Haggerty PV 8- Array Specifications ENERGY 38888 Pioneer Blvd 15298 SW Greenridge PL UNLIMITED sandy,OR 97055 Tigard, OR 97224 CCB# 185705 g 6/3/2014 1 _______ Array Specifications Enphase Internal Voltage Drop .._.._ Module From String Sizing SW 275 mono Inverter Inverter From String Sizing SB3000TL-US @ 240 Select Inverter ' String Configuration for Calculations 1 x 12 Used for M215&M250 Inverters Only-> STC Rating of MPPT 3,300 W Enphase Internal Voltage Drop 0.00 STC Rating of Array 3,300 WATTS Enphase Internal Voltage Drop% 0.00% Adj.Array Vmp @ ASHRAE 2%High Temp 427.91 VDC Adj.Array Vmp @ ASHRAE Avg. High Temp 310.0 VDC Single Inverter AC Voltage Drop Rated lsc For Specified Array 9.6 ADC Max. System Voc @ ASHRAE Low Temp 520.2 VDC Conductor Type Copper ' Voltage @ Rated Max Power(Typ. Op.Vmp) 372.0 VDC Wire Size(AWG) 12 Current @ Maximum Power Point(Imp for array) 8.9 ADC Length of Inverter Output Circuit 8 ' Output Phase 1 ' Minimum Wire Size to Keep VD<2% 18 PV Source Circuit DC Voltage Drop Calculated VD with selected wire size(%) 0.17% Conductor Type Copper Wire Size(AWG) 10 Multiple Inverter AC Voltage Drop Length of PV Source Circuit in(feet) 75 Number of PV Source Circuits 1 Conductor Type ".4 Minimum Wire Size to Keep VD <2% 14 Wire Size(AWG) ' Calculated VD with selected wire size(%) 0.56% Length of Inverter Output Circuit ' Number of Inverters ' Output Phase ' PV Output Circuit DC Voltage Drop Minimum Wire Size to Keep VD<2% #DIV/0! Calculated VD with selected wire size(%) 0.00% Conductor Type Wire Size(AWG) Length of PV Source Circuit in(feet) ' Total Voltage Drop Combined Output Circuit? ' Minimum Wire Size to Keep VD <2% #DIV/0! Total DC Voltage Drop: 0.56' Calculated VD with selected wire size(%) 0.00% Total AC Voltage Drop: 0.17% Contractor Information Project Information Energy Unlimited LLC Kelly and Jackie Haggerty PV 9- VOLTAGE DROP EN E RGY 38888 Pioneer Blvd 15298 SW Greenridge PL UNLIMITED Sandy,OR 97055 Tigard, OR 97224 CCB#185705 g 6/3/2014 ' Existing I DC+ string of 8 SW255 N/ \Z N/ NZ NZ N/ \/ DC- modules ��DC D ----+ ----+ --+ --+ ---+ - • C DC DC DC DC DC T t t t t t T Additional N/// \\/// \\/// \,// \/,/ + - - - - - - -' + --+ - I --+ --� - 75�Wire Run string of 12 DC DC DC DC DC DC DC ; DC DC DC DC DC (2)AWG#10,USE-2/RWII-2, Black SW275 - _ _ _ - _ ; (2)AWG#to,USE-2/RWH-2, Red modules T T T T T (I)AWG#6, Stranded bare copper AWG#6,Stranded Bare Copper Ground Rod;5/8"x 8'Copper will- lir Existing SB2000 Inverter SMA SB3000 J(r)2 pole 4o TL-US u)240V Inverter Inverter O amp circuit breaker transformerless Inverter GFP GFP 8'Wire Run N GND -- EIM N GND .-- r1=3-1 (i)AWG#1o,THWN-2, Black t7 r7 m0 o rn r- r- n n n r- N n n 0 (1)AWG#10,THWN-2, Red 1-, N + n + n (I)AWG#io,THWN-2,White (I)AWG#6,THWN-2, Green • • • t • • • t f 1 T I i �,--- j A� AC Combiner Box e GKI c i L1 nG O i L2 � � � + '.I N I I EGC/GEO r'I ,GCLGEC �___ - � AC distribution Panel \ — A Customer Generation Meter Contractor Information Project Information Energy Unlimited LLC Kelly and Jackie Haggerty PV10- ELECTRICAL DIAGRAM ENERGY 38888 Pioneer Blvd 15298 SW Greenridge PL UNLIMITED Sandy,OR 97055 Tigard, OR 97224 CCB#185705 g 6/3/2014 4111 SunmoduPlus SW 275 m©no Sunmodule%Plus SW 275 mono PERFORMANCE UNDER STANDARD TEST CONDITIONS(STC)' PERFORMANCE AT R00 VOW,NOCT,AM 15 e tuv,e + was % Maxlmumpower Nc Mexfmum power c 0 .: 4_„,Ai 1J0 7ower.ontrolled: ,•,,...•-^µ"�".-_ Open Mat voltage ?3.4'+., Open[agile voltage rawwud.Aei ..owest•re,suringto erance in i,ndntry Maximum power point voltage >. v Maximum power point vettage „. », n short Was n[uneat s.:EA Short&ornarrrent Ir '?SA osis ♦ ♦ *. . Mostrmfm peafo otm current ,�• E.•54A Maximum gamer pvuntcaveat r:;a t w. rN l:nc pall ,n,. ..41,,rc,, ti (\ +u.f,r,Ie.nrAM:I,twh .t,,,.',,kriar. ..:lit:',,,,,..c^-k,e: ts0•y coospooent is tested to rnPci • . 3 times Iti.req21 z.;ants •- •” COMPONENT MATERIALS . ..r O THERMAL CHARACTERISTICS Cells pet module ss,; -. ♦ ♦ _ 4. A... ♦ -- : MOOT st-,: UP type Woo Ire • _ tot, 94 13...'1C1 fli Cen 'N Designed teithsto-d Heavy • �. _.i ' __ FC,,,, - few C.4 1.!r rr G f na .•^I T n s as„EH Ci accumulations of s'ovi anc ice IC P.,, y'�• Frame r-a.alosnec a.... lurr ,.•;;°© Opemtmg temperature a ,c€`r Weight :6.r!hi i3'..:k; SYSTEM INTEGRATION PARAMETERS Su^madUc Ph,: - _• • * _ i` GOWnn Mammum systemwvhoge4t u icy:_... . Po.-t ye pertcr man cetolera^ce Max.system vottage USA NEC r-:0 ml.t kip© @7il Vern. Maximum reverse current 'CA • + - .♦ -. 4 ♦ _. W. -.-_ flea,..M: wmeerofbypass dialer a Iii f ut Design toads` Two rayl system f,w sir 25 year linear tn-for ante'h'ar'ant'? •”" -♦ ♦ 4 - 400 W^' Vt Design1Md5' rhre¢mlt. tem 1 d'NrN3re and 10-year pr.:Jet Warranty I _.. -.._ --__. -.. _ •E upvrarc ♦ - IFC Design loads Fwo1411 system Nrwarc 4 * .. 1-ca W,sn> 0 upN'are -,rTslCl'-'rC-ac,_arlS'-' ..t L.t.....:e.r.1r, s...:a..wnfi 40 Glass with anti elective coating - .wcaaa wltaErM y..� ADDITIONAL DATA � ...a 1 sown sorting' -0 et, tt.4 m • /Hope rt'.. ... - -. r Module leads v'N'e:el J.a 104 wit 5 Haf, ct0li World-doss quality ,n' Maasieeffr[len[y r .x; folly-3utorna:ed produ•tion h're,and seam�.ess monitoring of the process arc rratera s°e ; ? ( lire rating(ut 70dl Class: .... ' x t ... ..., enscre the goal ty chat he company Gets as its benchmark ford',sites wordwide. ' ' I �- class row'_.te'rpered N the AS: SoiarW�oridPlus-Sorting / a S�` „. P ios-Sortir g goarant^-es highest system efficiercy t clarWnr d only oe"vers mO9uies tnat : 15 2.41.1 have greater Char or ed I,ai to the nameplate rated power. ' ul '703 VERSION 3.5 FRAME 1 1 r •4 {a tie e: 11 1:f :,...ret 25 years linear performance guarantee and extension of product warranty to 10 yearsE 18801.1001 5i•-•I ' " eta I ,u t 1•,ler s,ls SclarrL'orld ua artees a maxlmurn emrrnanr_e depes ion of 0 c p.a.1n.he course of CerWW r,1- 'rr i - ng 1. a u E P _ , •1 c thefts-. years,a tvmflcantadded valuec mpardtothetwophasewaranties mrnoninthe i •l1,7;710n5 alo g eleng-haft-c industy.In addition,Solar world-scftering a proton warranty,which has been ex:ended • ` ntn.fide i^.the Wm*:flange' to10 years � �€r>� I. r acre id4r cm s h the 3 f ir3 a:'3rS1'or.].Il-ited'wlrra ti at purl,. 1111111 �- AWA.=.31'N jC0 N3r{a^v ,..a �! •■■■_ s, r.re N£w! Indeperd nt y c'ea ed PAN li',es row avaitable. SOLARWORLD -— Ask your acc or:manager fpr more 1nformatior. \..r../ solarworld.com We turn sunlight Into{lower. r n 1 r-x a - r 1 a I cat,r ,,,krW0,1,-C•rsr ,r,E,11. 1 ,p,-,,An r- chc,'Mt:r. W-C1-GDc'-s 3'-.C14 Contractor Information Project Information Energy Unlimited LLC Kelly and Jackie Haggerty PV 11- MODULE EN E RGY 38888 Pioneer Blvd 15298 SW Greenridge PL CUT SHEET UNLIMITED Sandy,0R97055 CCB#185705 Tigard, OR 97224 6/3/2014 SMA Tadnicol data Sunny Boy 3000Tt•US Sunny Boy 380011.-US H lnput(DC) 208 V AC 240 V AC 208 V AC 240 V AC 9 Input(DC) Max.usable DC power(•cos W••1) 3200 W 4200 W Max.DC voltage 600 V 600 V ' `�...�. ... Rated MPPT voltage range 175-480 V 175-480 V - Hove efficient MPPT operating voltage range 125 V-500 V 125V-500V f Y Min_DC voltage/start voltage 125V/150V 1254/150V Max.input current/per MPP tracker 18A/15A 24A/15A a, 3 Number of MPP trackers/strings per MPP tracker 2/2 S ;EE AC npn'rtal)power 3000 W 3330 W 3840 W �� '■I Max,AC apparent power 3000 VA 3330 VA 3840 VA e ji � ■■ ROI Nominal AC voltage/adjustable 208 V/• 240 V/• 208 V/• 240 V/• AC voltage range 183-229 V 211-264 V 183-229 V 211-264 V a Shade R1onagement AC grid frequency;range 60 Hz/59.3-60.5 Hz 60 Hz/59.3-60.5 Hz q tr Max.output current 15 A 16 A Power factor(cos w) 1 1 Output phases/line connections 1/2 1/2 a Harmonics <4% <4% — i Iti y Max.efficiency 96.8% 97.1% 96.8% 97.2 r� CEC efficiency 96% 96.5% 96% 96.5% "' = Protection devices / DC disconnection device • qtr 11/111 Easier DC reverse-polarity protection • THE WORLD'S ONLY Ground fault monitoring/Grid monitoring it/• SECURE POWER SUPPLY 1' AC short circuit protection • i - _' '. ;. ., 1 +1 10^p All-ole sensitive residual current monitoring unit • fi : ,.� Arc fault circuit interrupter(AFCt}Compliant b UL 16998 5 a ( - Protection class/overvoltage category I/1V z.r` ' fes ; 40xP General data j Dimensions(W/H/0)in mm(in) 490/519/185 (19.3/205/7.3) DC Disconnect dimensions(W/H/D}in mm(in) 187/297/190 (74/11.7/7,5) Certified innovative PowaisA Flexible Hoed temperature range Pocking dimensions(W/H J D)in mm(in) 617/597/266 (24.3/233/10.5) •UL 1741 sect 16994 anytime •Seam Power Suppprei6s •97.2%4.i e.Bde+uy •T.ve MMee ketsprosrd. DC Disconnect packing dimensions[W J H J D}in mm{in} 370/240/280 (14.6/9.4/11.0) •Inrgrud Mei near ere...qui.* d/ar+paw.be^g PMametez • 1ePwuasps rape mowdodo, _.. Weight/DC Disconnect weight 24 kg(531b)/3.5 kg (8 Ib) e mes al NEC 2011690.11 •bale e-royrwre withs OpttTr •Btrrdsd ep.i r8 - pubat Pent Mw comp Pack g weight/DC Disconnect packing weight 27 kg (60 IL)f 3.5 kg {$Ib) Operating temperature range -40°C_,+60°C(-40°F...+140•F) Noise emission(typical) 5 25 dB(A) <25 d8(A) SUNNY BOY 300011-US/380011-US/ Internal consumption at night <,w <,w Topology Tronsformerless Transformerless 400011-US/500011-US/6000TL-US cooling concept Convection Convection secure Pewwar Supply £tectonics protection rating NEMA 3R NEMA 3R Setting new heights in residential inverter performance Features Secure Power Supply • • The Sunny Boy 3000T4US/3800TLUS/4000 IAJS/S000TL-US/6000n•US represents the next step in perfonnonce for , Di graphic • • UL certified inverters.Its tronsformedess design means high efficiency and reduced weight.Muru o dm power productionInterfaces: 9s R5485/Speedwire/Welxonnast O/O 0/0 is derived from wide input voltage and operating temperature ranges.Muliph MPP itadrers and OptiTrac*Gbbal Peak I Warranty 10/15/20 years •/o/o 1/0/0 mitigate the sited of shade and allow for installation of challenging sites.The unique Secure Power Supply feature provides Certificates and permits(more avoi4able on request) 1.111741.1.1 1998,Ut 169qa B¢1w,KCsw is}Ciao',AK CAN/75AC22.210711 daytime power in the event of a grid outage-High performance.8exfih design and:mow:give features make the Sunny Boy TL-US series the fast choice among solar professionals. NOTE US inverters ship with gray lids ®gi.48 f9ED `" INGfNEttED Fle ilslecommunications Type designation S8 30001L-US-22 SB 380011.-US-22 ASS EM B LED52 IN THE USAIR Ted-irks'data contn,ed on bodr Contractor Information Project Information Energy Unlimited LLC Kelly and Jackie Haggerty PV 12 - INVERTER CUT SHEET ENERGY 38888 Pioneer Blvd 15298 SW Greenridge PL UNLIMITED Sandy,OR 97055 and, OR 97224 CCB#185705 Tigard, 6/3/2014 • I 2.0 I __-- �� , 3.0 . 4. - _ 8) c.=-.fix`-- _ 6.0 L_______1..,,,,,, 111 7Th, 12.0 I _J lin =-- r 5`�1 '�4 ITEM DESCRIPTION QTY. 1. ---------1-3) 1 Flashing, 12"x12"x.050"', Al * 1 2 Base Block, QMSC. Cast AI* 1 ..__, 3 Hanger Bolt. 5/16"x 6", SS 1 4 Washer, Sealing, 5/16"ID x 3/4"OD, SS/EPDM 1 5 Hex Nut, 5/16-18, SS 2 1---\, 6 Washer, .296"ID x 7/8"OD x 1/g'Thick, EPDM 1 9 Ih 2 i 7 Washer, Fender 5/16"X 1"SS 1 / 8 Washer, Split-Lock, 5/16", SS 1 _______..___._.______.__ *Available in mill, clear anodized, and black anodized finishes. j',' f� , Quick Mount Pik' , 1 `� TITLE: I' �1 QMSC: Classic Composition Mount L _ __..I UNLESS OTHER WSE S'ECIFIED: $IZE DRAWN BY: JDA REV -. C MEM ONS ARE N NC-IES TOLERANCES FRACTIONAL 3 ;16 A DATE: 2/7/2012 3 FROPIWARr Alb COu1100411At TWO PLACE DEC MAL S01 1.7E E.FCRbM` I COL RAE ED t,THC NhlS I+;t MESCLE PROPEPTY Cf Cu CR MCJ.T P,.AI AY R^..(.,i..'1CF II PTC A: DO NO-SCALE DRAO:NC; AvnOLE*PIOT'THE V141.10 PEm.u:Cr OF LCKteC,.t1 �.Pk sPP:0E4 THREE PACEDeemk.. t.cos SCALE:1:4 WEIGHT:0.97 SHEET 1 OF 1 Contractor Information Project Information Energy Unlimited LLC Kelly and Jackie Haggerty PV 13- Mounting System Data EN E RGY 38888 Pioneer Blvd 15298 SW Greenridge PL Sheet UNLIMITED Sandy,0R 97055 Tigard, OR 97224 CCB#185705 g 6/3/2014 1. (12) SolarWorld SW275 Modules • 2. (1) SMA SB3000 TL-US Inverter Notes 3. (1) Customer Generation meter Need to be sure to use PV rated wire wherever wire is exposed 4. (1) Customer Generation Meter base • 5. (1) Meter base cap 6. (4) DPW P6 solar rail 240" 7. (8) DPW end clamps for SW modules 8. (20) DPW Mid clamps for SW modules 9. (24) Quickmount PV solar mounts 10. (12) WEEB washers for SolarWorld Panels 11. (4) grounding lugs with WEEBS and hardware for DPW rail 12. (1) Solodeck combiner box Contractor Information Project Information Energy Unlimited LLC Kelly and Jackie Haggerty PV 14- MATERIALS LIST ENERGY Y 38888 Pioneer Blvd 15298 SW Greenridge PL Sandy,OR 97055 CCB#185705 Tigard, OR 97224 6/3/2014