Loading...
Report (43) (&[O/ c 7) Capitol :26 ::: -47191?//116 4 Electric Co., Inc. �U6 p4 2 016 all nr 1,4 August 01, 2016 (11 B Plans Examiner City of Tigard Building Services 13125 SW Hall Blvd. Tigard, OR 97223 Re: Tenant Fire Alarm System Additions Perlo Construction TI, Suite 140 @ Building A 16101 SW 72nd Avenue Tigard, OR 97224 Please find attached building and electrical permit applications,three sets of plans, calculations, and product submittals for the fire alarm tenant improvements at the address shown above. The fire alarm system design alterations include the following: 1. Install new ADA synchronized fire alarm notification devices in the tenant space including (3) horn/strobes. 2. Relocate ADA synchronized fire alarm notification devices in the tenant space including (2) horn/strobes. 3. We will pre-test the fire alarm devices prior to requesting a final fire alarm inspection. Please contact me if you have questions or comments. Resp ctfully, -TIN Shane Terc k Project Manager/Estimator Fire/Life Safety Division Capitol Electric Company, Inc. (503) 262-0405 Direct it _ shane@cepdx.com NICET Level II, Fire Alarm Systems #140599 t 11401 NE Marx • Portland, Oregon 97220-1041 • 503-255-9488 • Fax 503-257-7121 CCB# 48748 • www.capitolelectricco.com SYSTEM �� SENSO ' Y AUG 042016 , Selectable Output nor, TIGARf Notification Device TIJ piNc jvlsI1 E1/4 SpectrAlert°Advance selectable-output horns,strobes, and horn/strobes are rich with features guaranteed to cut installation times and maximize profits. SPECTROVIert amiarzy A N C The SpectrAlert Advance series of notification appliances is Features designed to simplify your installations,with features such as:plug in • designs,instant feedback messages to ensure correct installation of Plug in design individual devices,and eleven field-selectable candela settings for •Same mounting plate for wall-and ceiling-mount units wall and ceiling strobes and horn/strobes. •Shorting spring on mounting plate for continuity check before installation More specifically,when installing Advance products,first attach a universal mounting plate to a four-inch square,four-inch octagon or Captive mounting screw double-gang junction box.The two-wire mounting plate attaches to •Tamper resistance capability a single-gang junction box. •Field selectable candela settings on wall and ceiling units:15,15/75, Then,connect the notification appliance circuit wiring to the SEMS 30,75,95,110,1 15,135,150,177,185 terminals on the mounting plate. •Automatic selection of 12 or 24 volt operation at 15 and 15/75 candela Finally,attach the horn,strobe or horn/strobe to the mounting plate Outdoor wall and ceiling products by inserting the product's tabs in the mounting plate's grooves.The device will rotate into position,locking the product's pins into the •Outdoor products rated from-40°to 151°F mounting plate's terminals.The device will temporarily hold in place •Minimal intrusion into the back box with a catch until it is secured with a captured mounting screw. SpectrAlert Advance products allow you to choose: ▪Horn rated at 88+dbA at 16 volts •12 or 24 volts •Rotary switch for tone selection •At 24 volts,15,15/75,30,75,95,110,115,135,150,177 or 185 • candela by way of rear-mounted slide switch and front viewing 3 horn volume settings window •Electrically compatible with existing SpectrAlert products •Horn tones and volume by way of rotary switch The SpectrAlert Advance series includes outdoor notification Agency Listings appliances.Outdoor strobes and horn/strobes(two wire and four wire)are available for wall or ceiling.Outdoor horns are available for SIGNALING wall only.All System Sensor outdoor products are rated between ® MEA 'y 7125-1653:IA6(ind000,slobs) /�,� 7125-7653:1A7(oucdoor strobes) minus 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or 7175'1653183(hornlstrobes) g LISTED APPROVED approved /I 5-1653:139(horns) dry applications. 54011 3023572 MEA452-0S-E SpectrAlert Advance Specifications Architect/Engineer Specifications General SpectrAlert Advance horns,strobes and horn/strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch octagon back box or double-gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 1k-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,SpectrAlert Advance products,when used with the Sync•Circuit" Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync.Circuit Module,12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts;24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC,or full-wave rectified,unfiltered power supply.Strobes and horn/strobes shall have field-selectable candela settings including 15,15/75,30,75,95,110,115, 135,150,177,185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn/Strobe Combination The horn/strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn/strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal(continuous) pattern.These options are set by a multiple position switch.On four-wire products,the strobe shall be powered independently of the sounder.The horn on horn/strobe models shall operate on a coded or non-coded power supply. Outdoor Products SpectrAlert Advance outdoor horns,strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahrenheit.The products shall be listed for use with a System Sensor outdoor/weatherproof back box with half inch and three-fourths inch conduit entries. Synchronization Module The module shall be a System Sensor Sync•Circuit listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn/strobe models over a single pair of wires.The module shall mount to a 41)16 x 4'X6 x 276-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) K Series Operating Temperature —40°F to 151°F(-40°C to 66°C) Humidity Range 10 to 93%non-condensing(indoor products) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR1 Operating Voltage Rangel 8 to 17.5 V(12V nominal)or 16 to 33 V(24 nominal) Input terminal wire gauge 12 to 18 AWG Ceiling mount dimensions(including lens) 6.8-diameter x 2.5"high(173 mm diameter x 64 mm high) Wall mount dimensions(including lens) 5.61 x 4.7"W x 2.5"D(142 mm L x 119 mm W x 64 mm D) Horn dimensions 5.61.x 4.7W x 1.3"D(142 mm L x 119 mm Wx33 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. A05-0395-002 , UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-175 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15/75 142 148 77 81 Temporal Medium 44 49 58 69 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-temporal High 57 56 69 75 95 NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-wire Horn/Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-temporal High 141 152 91 100 116 176 201 221 229 Non-temporal Medium 133 145 75 85 102 163 187 207 216 Non-temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-temporal High 142 161 103 112 126 181 203 221 229 Non-temporal Medium 134 155 85 95 110 166 189 208 216 Non-temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-wire Horn/Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-temporal High 255 270 303 309 Non-temporal High 233 248 275 281 Non-temporal Medium 242 259 293 299 Non-temporal Medium 219 232 262 267 Non-temporal Low 238 254 291 295 Non-temporal Low 214 229 256 262 Horn Tones and Sound Output Data Rotary Horn and Horn/Strobe Switch Settings Horn and Horn/Strobe Output(dBA) Setting Repetition Rate dB Level Switch 8-17.5 Volts 16-33 Volts 1 Temporal horn High Position Sound Pattern dB DC FWR DC FWR 2 Temporal horn Medium 1 Temporal High 78 78 84 84 3 Temporal horn Low 2 Temporal Medium 74 74 80 80 4 Normal horn High 3 Temporal Low 71 73 76 76 5 Normal horn Medium 4 Non-temporal High 82 82 88 88 6 Normal horn Low 5 Non-temporal Medium 78 78 85 85 7* Externally coded High 6 Non-temporal Low 75 75 81 81 8* Externally coded Medium 7* Coded High 82 82 88 88 9* Externally coded Low 8* Coded Medium 78 78 85 85 9* Coded Low 75 75 81 81 *Settings 7,8,and 9 are not available on 2-wire horn/strobe. A05-0395-002 SpectrAlert Advance Dimensions r_____4.7" ► ,■ 1' I' Dia. 1111 ;jam ,,,lit( ;r.f 1.5" K--%..._ -,05-7) III irli ill yi / SpectrAlert Advance Ordering Information Model Description Model Description Wall Horn/Strobes Ceiling Horn/Strobes(contd.) P2R*' 2-wire Horn/Strobe,Standard cd*,Red ti_PC2W*1; 2-wire Horn/Strobe,Standard cd,White P2RH* 2-wire Horn/Strobe,High cd,Red PC2WH*t 2-wire Horn/Strobe,High cd,White P2RK* 2-wire Horn/Strobe,Standard cd,Red,Outdoor PC4R 4-wire Horn/Strobe,Standard cd,Red - P2RHK* 2-wire Horn/Strobe,High cd,Red,Outdoor PC4RH 4-wire Horn/Strobe,High cd,Red P2W* 2-wire Horn/Strobe,Standard cd,White PC4RK 4-wire Horn/Strobe,Standard cd,Red,Outdoor P2WH* 2-wire Horn/Strobe,High cd,White PC4RHK 4-wire Horn/Strobe,High cd,Red,Outdoor P4R* 4-wire Horn/Strobe,Standard cd,Red PC4W 4-wire Horn/Strobe,Standard cd,White P4RH* 4-wire Horn/Strobe,High cd,Red PC4WH 4-wire Horn/Strobe,High cd,White P4RK 4-wire Horn/Strobe,Standard cd,Red,Outdoor Ceiling Strobes P4RHK 4-wire Horn/Strobe,High cd,Red,Outdoor SCR* Strobe,Standard cd,Red P4W* 4-wire Horn/Strobe,Standard cd,White SCRH* Strobe,High cd,Red P4WH* 4-wire Horn/Strobe,High cd,White SCRK Strobe,Standard cd,Red,Outdoor Wall Strobes SCRHK Strobe,High cd,Red,Outdoor SR*t Strobe,Standard cd,Red SCW*t Strobe,Standard cd,White SRH*t Strobe,High cd,Red SCWH*` Strobe,High cd,White SRK Strobe,Standard cd,Red,Outdoor Horns SRHK Strobe,High cd,Red,Outdoor HR Horn,Red SW* Strobe,Standard cd,White HRK Horn,Red,Outdoor SWH* Strobe,High cd,White HW Horn,White Ceiling Horn/Strobes Accessories PC2R* 2-wire Horn/Strobe,Standard cd,Red BBS-2 Back Box Skirt,Wall,Red PC2RH* 2-wire Horn/Strobe,High cd,Red BBSW-2 Back Box Skirt,Wall,White PC2RK 2-wire Horn/Strobe,Standard cd,Red,Outdoor BBSC-2 Back Box Skirt,Ceiling,Red PC2RHK 2-wire Horn/Strobe,High cd,Red,Outdoor BBSCW-2 Back Box Skirt,Ceiling,White Notes: *Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g.,P2R-P t Add"-SP"to model number for"FUEGO"marking on cover,e.g.,P2R-SP #"High cd"refers to strobes that include 135,150,177,and 185 candela settings."Standard cd,"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings. • T SYSTEM3825 ©2006 System Sensor. '�1 S�CA'c^Q Ohio Avenue•St.Charles,IL 60174 Productspecifi;ationssubjeatochanjewahoutnotice.Ursicsystemsensorarnfor ENSORPhone:800-SENSOR2•Fax:630-377-6495 current product information,indudngthe latest versiono`this data sheet. A05.0395-002.7/06•x1659 ) NAC EOL VOLTAGE CALCULATION P CAPITOL ELECTRIC CO., INC. (503) 255-9488 Office AUG 0 4 2015 (503)255-1966 Fax CI ''Of .,FI .Gl .) Job Name: Building-A BUILDING DIVISIOrt Job Address: 16101 SW 72nd Ave. Tigard, OR 97224 Job Number: Conductor Wire Gauge 14 Prepared By: Dan Wilson Ohms Per 1000 Ft @ 75 Deg C ( 167 Deg F ) 3.07 Date: 7/22/2016 Cable Length In Feet(source to end of line) 389 Total Circuit Current 0.714 Nominal System Voltage 20.4 Panel Description: Silent Knight 5495-7 Power Supply Minimum Device Voltage 16 Panel No.: NAC 1.1 Output No.: 4 Point To Point Method EOLv 19.15 Circuit Within Limits ? YES NAC Devices Mfg By: System Sensor Load Centering Method EOLv 19.55 Circuit Within Limits ? YES Dev Device Location Device Model No. & Description Candella Alarm Distance From Voltage At No. Rating Current Previous Device Device Feet 1 Suite 140 PC2W 75cd H/S, Ceilin•, Wht, H 75 0.176 170 19.65 2 Suite 140 PC2W 15cd H/S, Ceilin., Wht, H 15 0.079 44 19.51 3 Suite 140 PC2W 30cd H/S, Ceilin., Wht, H 30 0.107 70 19.31 4 Suite 140 PC2W 75cd H/S, Ceilin., Wht, H 75 0.176 47 19.21 5 Suite 140 PC2W 75cd H/S, Ceilin., Wht, H 75 0.176 58 19.15 6 --__ 19.15 7 --�-� 19.15 8 ---_ 19.15 9 -- 19.15 10 -- 19.15 11 -- 19.15 12 --� 19.15 13 --, 19.15 14 --_- 19.15 15 --_- 19.15 16 -- 19.15 17 ---_ 19.15 18 -- 19.15 19 ---- 19.15 20 -- 19.15 NAC 1.1 EOLv Calc.xls OUTPUT 4 } NAC EXTENDER BATTERY CALCULATIONS CAPITOL ELECTRIC CO., INC. (503) 255-9488 Office, (503) 255-1966 Fax JOB NAME: Building A ADDRESS: 16101 SW 72nd Avenue Tigard,OR 97224 DATE: 8/1/16 PANEL DESCRIPTION: SK 5495-)or PREPARED BY:Shane Tercek DEVICE TOTAL DEVICE TOTAL STANDBY STANDBY ALARM ALARM DEVICE QUANTITY CURRENT CURRENT CURRENT CURRENT NAC EXTENDER Silent Knight 5495 NAC Panel 1 0.075 0.075 0.175 0.175 CIRCUIT#1 ? Estimated Load 1 • 1.500 0.000 - ' 0.000 0.000 0.000 • ` 0.000 ,--«.; 0.000 0.000 0.000 TOTAL 1.500 CIRCUIT#2 ?- Estimated Load 1 • 1.500 P e:. F 0.000 - 0.000 0.000 0.000 0.000 - 0.000 0.000 �'� Mx_.' ' �y' : �":: �• a ' `'' � ��" TOTAL 1.500 CIRCUIT#3 ? Estimated Load 1 j 1.500 0.000 0.000 0.000 0.000 • 0.000 0.000 - 0.000 s s` 0.000 ry TOTAL __1500 CIRCUIT#4 Suite 140 PC2W 75cd H/S,Ceiling,Wht,Hi 3 " 9 0.176 0.528 PC2W 30cd H/S,Ceiling,Wht,Hi 1! 7v 0.107 0.107 PC2W 15cd H/S,Ceiling,Wht,Hi 1 rl 0.079 0.079 q 0.000 0.000 - 0.000 - : 0.000 0.000 0.000 TOTAL 0.714 NAC 1.1 Batt Calc.xls Page 1 of 2 NAC EXTENDER BATTERY CALCULATIONS CAPITOL ELECTRIC CO., INC. (503)255-9488 Office, (503) 255-1966 Fax JOB NAME: Building A ADDRESS: 16101 SW 72nd Avenue Tigard,OR 97224 DATE: 8/1/16 PANEL DESCRIPTION: SK 5495-xx PREPARED BY: Dan Wilson DEVICE TOTAL DEVICE TOTAL STANDBY STANDBY ALARM ALARM DEVICE QUANTITY CURRENT CURRENT CURRENT CURRENT AUXILIARY DEVICES 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 STANDBY TOTAL CURRENT: 0.075 STANDBY HOURS: 24 STANDBY AMP HOURS: 1.800 NAC DEVICE CURRENT 5.214 ALARM TOTAL CURRENT: 5.389 ALARM MINUTES: 5 ALARM AMP HOURS: 0.449 TOTAL CALCULATED AMP HOURS 2.249 APPLIED SAFETY FACTOR 1.20 MINIMUM AMP HOURS REQURED 2.699 SELECTED BATTERY SIZE 12 EACH 12 VOLT, 7 AMP HOUR BATTERIES NAC 1.1 Batt Calc.xls Page 2 of 2