Plans (48) RECEIVED MAR 7 2013 CITYOFTIGARD PROJECT INFORMATION BUILDING DIVISION OWNER MEATH RESIDENCE CONTRACTOR ADVANCED ENERGY SERVICES 12445 SW BELL COURT 14755 SE 82ND DRIVE I TIGARD,OR 97223 CLACKAMAS,OR 97215 MAIN:503-635-0117 CONTACT:JORDAN WEISMAN BUILDING SINGLE FAMILY RESIDENTIAL PHONE:503-407-6820 DATA ROOF SPECS ASPHALT COMPOSITE SHINGLE ROOF(SINGLE LAYER) I/j APPLICABLE 2010 OREGON SOLAR INSTALLATION WI 2X4 TRUSSES DOUGLAS FIR#2 Q 24'0.C. ! CODES SPECIALTY CODE TILT:18 DEGREES r AZIMUTH:100 DEGREES SYSTEM SOLARWORLD 255W MONO& ROOF AREA(PLAN VIEW)= 2,025 SF SOLARWORLD 260W (8 MODULES) ARRAY AREA= 185 SF ARRAY IS<25%OF ROOF AREA 5 X 255W-1.275kW 3 X 260W- .780kW MODULE SOLARWORLD SUNMODULE SW 255W MONO&SW 260W TOTAL SYSTEM-2.055kW SPECS MAIN MEre•• (L)66'X(W)39,5'X(H)1.34° WEIGHT:47.6"LBS MAIN PANEL t��� r (8)ENPHASE M215 INVERTERS, D COMBINED WEIGHT OF MODULES AND RACKING IS< 1 INVERTER AT EACH MODULE 4,5 PSF. ti MAYr i• PROJECT NOTES g 1 i 1. 303.2- PV SYSTEMS AND SUPPORTING STRUCTURE 7. ROOF STRUCTURE IS CONVENTIONAL LIGHT FRAMED • ''= SHALL COMPLY WITH REQUIREMENTS OF OSSC WOOD CONSTRUCTION WITH 2X4 TRUSSES AT 24" 0.C, CHAPTER 6 OR THE ORSC AS APPLICABLE. MAX. EXEMPT FROM ALLOWABLE SPAN REQUIREMENTS .,•Area CF Work 2. 303.3-ALL PV MODULES TO BE UL 1703 LISTED. IN TABLE 305.4.1. PV.arra.y: 3. 303.5- PV SYSTEM SHALL HAVE A FIRE 8. 304.9,5-DISCONNECTS,.I-BOXES,COMBINER BOXES OR CLASSIFICATION THAT IS EQUAL TO OR GREATER GUTTERS SHALL NOT BE PLACED IN ANY REQUIRED THAN THE ROOF ASSEMBLY REQUIRED BY OSSC PATHWAY OR CUTOUT. , SECTION 1505.1. 9. ROOF MATERIAL IS ASPHALT COMPOSITE SHINGLE. 4. 303.6-ALL COMPONENTS OF THE PV SYSTEM SHALL BE 10. PER 305.4 ITEM 3:TOTAL SYSTEM WEIGHT SHALL NOT RATED FOR THEIR USE, EXCEED 4.5 PSF.PV MODULES AND RACKING SHALL BE 5. 303.4-304,8-PV LAYOUT SHALL NOT RESTRICT DIRECTLY ATTACHED TO ROOF FRAMING AS SHOWN IN • EGRESS, LIGHT,VENTILATION,OR ROOF DRAINAGE CONNECTION DETAIL#2.ATTACHMENT SPACING WILL REQUIREMENTS. BE 48"O.C.MAX,AND WHEN ATTACHMENT LOCATED 6. 304.9.1 GENERAL PATHWAY REQUIREMENTS- WITHIN 3'OF ROOF EDGE, HIP,EAVE, RIDGE SHALL BE EXCEPTION 1:ON STRUCTURES WITH A PV ARRAY 24"0.C. MAX. AREA OF 1,000 SF OR LESS INSTALLED ON A ROOF 11. MAX MODULE HEIGHT< 12"OFF ROOF SURFACE. WITH A SLOPE THAT EXCEEDS 2:12 AND WITH AN 12. SECTION 304.7-MECHANICAL EQUIPMENT INTERSECTING ADJACENT ROOF AND WHERE NO CLEARANCES: NOT APPLICABLE,THERE IS NO SECTION IS LARGER THAN 150 FEET MEASURED IN MECHANICAL EQUIPMENT WITHIN OR ADJACENT TO LENGTH OR WIDTH. AREA OF WORK. EXCEPTION 1A: WHERE PV ARRAY DOES NOT EXCEED 25%AS MEASURED IN PLAN VIEW OF TOTAL ROOF AREA OF A STRUCTURE,A MINIMUM OF 12" UNOBSTRUCTED PATHWAY SHALL BE MAINTAINED ALONG EACH SIDE OF ANY HORIZONTAL RIDGE. NORTH Cf1) 1. SITE PLAN ADVANCED ENERGY SERVICES DATE: MARCH 6, 2013 PROJECT #: AES MEATH Scale: 1" ■ 30'-0" iiiiminiemilli 14755 SE 82ND DRIVE o' 15' 30' 60' CLACKAMAS, OR 97015 MEATH RESIDENCE 12445 SW BELL COURT CITY OF TIGARD 503.635.0117 TIGARD,OR 97223 CCB# 180882 Approved s� [1,.�" Conditionally Approved [ ] ,� DWG. 1 OF 3 See Letter to:Follow [ ] Att.ched [ Approved plans Permit Number. 4 G" ' 7 Addr- -• 4 4 - low— �1— shall be on job site_ • By: ink Date: likl OFFICE COPY • • • • • REFER TO •• 3 DRAWING 3 • . 3 FOR ROOF SECTION,TYP. • • • .1 .. 0 I 2X4 ROOF TRUSS . 0241'O.C.,1'P. \ I • 36" ATTACHMENT CONNECTION RAILSE,TYPTf ROOF AkA TRUSS,TY r . . " SOAR N x ,,, 7a 0 ARRAY N .EXIsr.VENT -moo is Area of SUNEYE • N r .. 1 * , READING Work . _ n , ,,ars :f :•47,t' e,` " • c0 I 1 1 1 -.i I 1 1 1 L _ _ _ _ _ _ _/ EXISTINGR OFRIDE_ .4 _ _ _ _ _ _1 J • N.0 1. ENLARGED ROOF PLAN Scale: 1/4" - 1'-0" ADVANCED ENERGY SERVICES DATE: MARCH 6, 2013 PROJECT #: AES MEATH 14755 SE 82ND DRIVE MEATH RESIDENCE CLACKAMAS, OR 97015 12445 SW BELL COURT 503-635-0117 TIGARD,OR 97223 CCB# 180882 DWG. 2 O F 3 SOLAR COLLECTOR MODULE MODULE(4.5 PSF,MAX.) DIMENSION fi VARIES '.:. fiiisC*KPIKii;:{;asst;iii rj • i 7, f 14+1+1444:10��+•••• 44 0•, �•i':basis isi:*•ii,,,:txii •1 :iib t•:::i 34..- :;:s• ::•''S'•:::l':•:S 1 MODULE DIMENSION "*•'•��:::f k'+4JiO!..:44 ; :.... 10'MAX ':i:•i;:�•.i4•. *:4.:•:::::X.:44%% '4:iso s if::f P•::•••;..•.••+ :: :da i i's•, SECTION A y;..b:;•+..i,.1'i+• i«.•.+.i;t..b: �.•fib i�i b•:.:40,.............:• f� !�bbi 'i, •ice;;:r1 i;::?;..::,: •,:;! i, a ids�••..i•, ♦s•i••isi.� �f�i SECTION A :.v.• „....4,4,,.........),� CONNECT SOLAR MODULE TO i—•`iii%•i's:,:+:�.4.:ii•'ff•O:+i:'!s:': RAILS WITH 1 CONNECTOR •`'s•::•:`�' O'•`�•+b:' �i`'I FOR EACH 8.S(1 FT.OR 4:'•i•:�.;.;i.•:+•::•ii;b• s;; LESS OF MODULE SURFACE .•••'•.....•.;...,.• CORROSION RESISITANT •••..•..•s;•••,:••'. p0�•bit••••;•..:.4 METAL RAIL ANCHOR AA rAW.�1.f•,0.. TO ALTERNATE ROOF ..y.Z.:::::;'''.1.7.'.7::: •��,'�i���i.•.�;y;+ FRAMING 48”MAX.ON _:4.• -s.,e:•.,..`...�:e.,.SS CENTER PER SECTION A-A II ;:�•'.• :+";• �'' TYPICAL.PROVIDE A b'"�•.i":'.aS..+s:.`: .... NEW SOLAR MODULE MINIMUM RFMO�LE ` I I I ARRAY AND ATTACHMENT SYSTEM TO EXISTING ROOF TRUSSES ROOF FRAMING ...5..f �� a,MAX ON CENTER -"----,./..,... 2. CONNECTION DETAIL j Scale: NTS \A/\,. EXISTING 2X4 TRUSSES COLLECTOR MODULE V 24"O.C.,TYP. MIN,2 X 4 RAFTER OR TRUSS CONTINUOUS SUPPORT CHORD V 2'MAX.ON CENTER RAIL AND CONNECTION POST CTR MANUFACTURER 1. SECTION ` SUNMODO EZ ROOF MOUNT AND FLASHING \ WITH 3"POST AND L FEET WITH 5/16"X 3" Scale: NTS STAINLESS LAG BOLT.INSTALL PER .4•44 MANUFACTURER'S INSTALLATION INSTRUCTIONS 3. CONNECTION DETAIL ADVANCED ENERGY SERVICES DATE: MARCH 6, 2013 PROJECT #: AES MEATH Scale: NTS 14755 SE 82ND DRIVE MEATH RESIDENCE CLACKAMAS, OR 97015 12445 SW BELL COURT 503-635-0117 TIGARD,OR 97223 CCB# 180882 DWG. 3 OF 3 EQUIPMENT SCHEDULE I NOTES: NEC PV LABELING REQUIREMENTS (1)PV ARRAY,5 SW 255W MODS,3 SW 260W MODS 2.055 KW SOLAR PV SYSTEM AC DISCONNECECTS&INVERTER(690.54): INV RTER.8 INVERTERS MAKE UP ONE EACH PANEL CONNECTED TO ONE 1RA 5 ENPHASE CH CIRCUIT.MICRO (3)6 AWG BARE COPPER EQUIPMENT GROUNDING CONDUCTOR WARNING:DISCONNECT IS ENPHASE M215 OUTPUT CIRCUIT PV Array-5, 255-Watt SoIarworid PV Panels SOURCES:SOLARSY TEMANDRUTILITYGIGRDD FROMTWO (4)AUUTILITY GRADE METER TOMEAS REIRES.PVOUTPUT (5)GRID INTERCONNECTION BY 15A TWO POLE BREAKER and 37260-Watt Solarworld PV Panels MAXIMUM AC LTAGE 240 Vac MAXIMUM AC RCURRENT 0.9 Aac/Inverter (6)8 200A GROUNDING HIN SERVICE PANEL WITH 200A MAIN D NG ELECTRODE CONDUCTORCONNECTED T O EXISTING BUILDING GROUNDING ELECTRODE. • w(1) AC CIRCUIT BREAKER(690.64) NOTES: - _ -THE SUM OF THE RATINGS OF BREAKERS FEEDING ANY PANEL WARNING:CIRCUIT BREAKER IS ENERGIZED FROM MUST NOT EXCEED 120%OF THE RATING OF THE PANEL BUS BARS TWO SOURCES-SOLAR SYSTEM AND UTILITY GRID. (NEC)690.64) (2) MAIN SERVICE PANEL (310 awg USE-2/RHW-2 AC POINT OF CONNECTION � Sunlight Resistant Wire plus SOLAR ELECTRIC SYSTEM One#6AWG Bare Copper Equipment Ground AC OUTPUT CURRENT:7.2A NOMINAL AC VOLTAGE:240V AC Voltage Drop Calculation 1,Internal Voltage drop within cabling:8 micro inverters=.31% WARNING 2.Voltage drop from branch circuit to dedicated OCPD:N/A INVERTER OUTPUT CONNECTION 3.Voltage drop from OCPD to Main Service Panel DO NOT RELOCATE THIS OVERCURRENT DEVICE %Vdrop=(0.9A*8)*(2*40ft) =(576*(.00124ohms/ft))/240V THIS PANEL IS FED BY TWO SOURCES OF POWER =0.0030*100 1-UTILITY 2-PV INVERTER =0.30%AC Voltage Drop Roof Top TOTAL AC VOLTAGE DROP:0.31%+0.30%=0.61% Ground METER Approximate distance from CUSTOMER OWNED SOLAR GENERATOR OUTPUT PROJECT: Shawn Meath Residence .411 roof top array to Main Electric Panel is 40 feet. 12445 SW Bell Ct. Tigard,OR 97223 3/4"EMT outdoors with 2.055 kW System two #10 awg 200A Main Panel Solar Contractor THWN-2 conductors w/(1)#10awg, 3/4"EMT from AC Disco THWN-2 Neutral,and#6 awg Meter Advanced Energy Services Equipment GND conductor to Main Electric Panel. 120/240 von, from array AC Disco to output meter Distance less than 10'. three-wire,single-phase located next to main service panel. PV ® (6) Output Meter 200A Main AZ14, Breaker TITLE: Single Line Diagram,Grid Tied Solar PV System in Utility (7) DATE: 3/6/13 DRAWN BY: Jordan Weisman (4 ISA 15A Two Pole��(5) iGrounding Drawing#:0001 PROJECT/Customer Shawn Meath Residence Name: Backfeed Breaker Electrode REVISION HISTORY DATE NOTES REVISION:00 #6 bare copper