Loading...
Plans (8) BtP2015 - 00375 RECEIVED DEC 30 2015 CITY Qty TtGARD GRUSKIN ■ BUILDINGDIVISION .294 Morris Avenue Springfield,NJ 07081 Tel: 973.376.4411 Fax: 973.376.8989 www.GruskinGroup.com NJ REG 0100.9869.14 This document and the Ideas and designs Incorporated herein, as an Instrument of professional service,is the property of GRUSKIN ARCHITECTURE+DESIGN,P.C.,and Is not to be used In whole or In part for any other project without the written authorization of GRUSKIN ARCHITECTURE+DESIGN,P.C. All Rights Reserved ©2015 Gruskin Architecture+Design,P.C. Kenneth A. Grwddn AIA AL 5421 MT 2537 AK 13167 NC 9961 AR 3811 ND 1666 AZ 39209 NE A-3547 CA C-29898 NH 2796 CO ARC-400347 NJ Al 09999 CT 9613 NM 004168 DC ARC100723 NV 5521 DE 0006261 NY 025528-1 NY FL AR91629 OK 04895 GA RA011075 OH 13761 HI AR 11489 1 OR 4899 IA 05713 PA RA-015432-8 ID AR-94459 PR 19965 IL 001-019152 RI 2666 IN AR10400066 SC 6834 KS 4674 SD 11532 KY 5967 TN 101374 LA 5734 TX 17680 ME ARC 2596 UT 5881358-0301 MD 11016 V1- 2572 MA 10635 VA 0401 011223 MI 1301052379 WA 10344 MN 44326 WI 9900-005 MO A-20050 9740 WV 3727 MS 3860 WY C-1967 Professional Seal: Washington Square Mall A.GRUSKIN 4899 9585 S.W. Washington Square Road PMGFIELD,NJ OF at Space : R05-07Porti n R 97223 .�► Consultant: � HENDERSON FA7JENGINEERSN 8325 LENEXA DRIVE LENEXA,KS 66214 TEL 913 742 5000 Fax 913 742 5001 www.hei-eng.com 1550003152 Job Name and Number. 2015-0131 Code Analysis Scope of Work Vicinity Map Drawing List Proposed The work covered in this set of construction documents is for the interior fit-up for the tenant space in Sheet Titles Rev. Sheet Titles Rev. V E R S ZO N Building: 2014 Oregon Structural Specialty Code existing mall which was built under separate building permits. A brief description of the work is as follows: f „n w C$ Cover Sheet Plumbing: 2014 Oregon Plumbing Specialty Code 1. Demolition work shall include removal of interior partitions, suspended ceilings,ductwork,soffits and STORE Electrical: 2014 Oregon Electrical Specialty Code finishes. In addition,floor trenching which will be required for new electrical stub up.See Demolition , �., �, :. ..., . Architectural Electrical 9 P tY x � � . plan. . ,m � ... A1.1 General Notes and Specifications (LEED) Mechanical: 2014 Oregon Mechanical Specialty Code 2. New work shall include construction of interior partitions, millwork, ceilings,door&door hardware,etc. r � Eeasarrnrc p E 1 Electrical Power Plan . x :::; ::€: ':iii .. a .. .. „9„ .:. : ;� .,� �� :: A1.2 General Notes and Specifications New interior floor and wall finishes to be Installed throughout.See Plans. ::::.::::::..:::.:,.............. .:...::,::::. p E2 Electrical Lighting Plan Fire. 2014 Oregon Fire Code g - ' •, 3. Mechanical work to include distribution ductwork from new air handler units. See Mechanical plans. :: :: ar�,r. rts«u,.a:; ..... A1.3 General Notes and Specifications St >; .....:: .. rd Schedule and Details Accessibility. ICC/ANSI A117.1 4. Electrical work to Include all distribution receptacles,lighting and power. See Electrical plans. , ..:.: � ...,. -.<, z �� >:. Jardra tapr:a3asc xlo6k :. 5. Plumbingwork to include adding service sink and floor sink and replacing existing toilets to the tenant : ' a ... Accessibility Details, Matrix and Egress Diagram Electrical Le vend, Details and Schedule 9 P 9 9 wi �, g Energy: 2014 Energy Efficiency Specialty Code >:.::. � ' space. Refer to Plumbing plans for Plumbing work. �° � Job Address A3 Demolition Plan E5 Electrical Details .Blom A4 Architectural Plan Washington Square Mall All work including but not limited to, general construction, plumbing, electrical and mechanical,shall be E5a Telco Room Details & Light Fixture Schedule b q n n .a. .}. 1afpleSfrxe$ &Watch.ni:{+mirtIx'C .- '> .?Ihim ,.,.,,�, performed in accordance with all codes listed on Code Analysis and Local Amendments. All work shall ' � � A5 Reflected Ceiling Plan and Details Electrical Specifications 9585 S.W. Washington BuildingAnalysis g E6 g y be done in a first class manner using standard construction practices and according to the rules and n SquareR ad regulations of the governing Building Department. A6 Furniture and Security Plan and Details E7 Electrical Specifications Portland, R 97223 a A7 Wall and Floor Finish Plan and Details o rid, 0 - Space R05-R07 Construction Type. II-N Sprinldered , x:. x A8 Interior Elevations and Construction Details LEED S p ` cad ..... 4 e �� 1Vettefc Prettelt rc Use Group: M (Mercantile) �� A9 Millwork Elevations and Details LEED1 LEED Prototype Green Specifications Seismic Design Category: D � A10 Door and Finish Schedules LEED2 LEED Prototype Green Specifications Drawing Title: Architectur I Symbols A11 Y y ��.. Area of Work(Gross}. 3,389 sq.ft. atIOI1S . ���� F1 Fixture List _ Exterior ev No. of Stories: 1 x k A CITY of Cover Sheet DETAIL ENLARGED PLAN DOOR ........ 'I'IGARD Tenant Improvement Location: Ground Floor xx NO OR NUMBER ' Plumbing REVIEWEDoR CO E COMPLIANCE SHEET DETAIL �. .::..:. P1 PPlumbin Plan Approved: r NO. REFERENCE ': : :::... .. . ....... �� :�� �� Y 0 ter. s � x ...... _ g OTC: Maximum Occupancy(Table 1004.1.1): I I »»." ] DATE REVISION P2 Plumbing Details and Schedules Drawn By. North Retail Sales`: 2,286 sf/30 =77 —J DETAIL NO./SHEET TRIANGLE P3 Plumbing Specifications Pcrrnit#: '2bt�j— '? �� Arrow. Office": 855 sf/100 =9 Address: Checked By. =__. Site Plan Mechanical Suite#: KG &Stock Rooms***: sf/300 = 1 x ELEVATION NO. ALL�/�N�'IEp NO�y LEED/GREEN �� Date Issued For ELEVATION B}: Dates 7 (G Client: 12/24/15 Total Occupancy: =87 SHEET NO. REFERENCE WILL BE BOXED A5 SHOWN NOTES - M2 Mechanical Plan Landlord: 12/24/15 Exit(s) Requirements(Table 1015.1): Required:2; Provided: 2 JCPenney Mechanical Details and Schedules I/ Permit: 12/24/15 «. KbA f V Required: Minimum Egress Width (Section 1005.3.2) - ___ e M3 Mechanical Specifications Bid: , Required: 87 x 0.20= 17.4" RETAIL 5ALE5 - j - M4 Mechanical Specifications OFFICE COPY construction: Minimum width: use 36"as a minimum x SECTION NO. SECTIONROOM NO. ROOM - '- Na Date Description Revision Issue: DESIGNATION Front door(2)36"width=72"/0.2=360 Occupants SHEET NO. REFERENCE SPORTING r Rear door 36"width=36"/0.2= 180 Occupants RETAIL SALES Gooas ROOM PlumbingFixtures: Table 2902.1 vv�v/ WALL FLOOR BASE FINISHES : _ I - ( ) M PLAN OR P-2 G-2 B-1 ; t Water Closet: Required:2; Provided:2X DETAIL TITLE Project Contact CEILINGLavatory: Required:2; Provided:2 1 u HEIGHT Bottleless Water Cooler. Required:0; Provided: 1 +10-0 n Architect Engineer MEP G1 ,4GT-1 CEILING MACY S - 9 ELEVATION DESIGNATION zl ';` 3 1 rl ;� ,, ► { :i 1...1 l.¢ _ Gruskin Architecture+ Design, P.C. Henderson Engineers Inc. 294 Morris Avenue 8345 Lenexa Drive, Suite 300 BOTTOM OF 1131-01 REFERENCE CEILING CEILING 3 Springfield, NJ 07081 Lenexa, KS 66214-1695 FACADE V.I.F. TYPE FINISH ;I -- t it Sprinkler System: ❑ No ®Yes ® Existing/Modified ❑ New ' NORDSTROM Tel: 973-376-4411 Tel: 913-307-5300 Berl r- 1 _ Deferred Submittals Special Inspection '' r°�3 `' I LEED Consultant Owner Sales areas include Retail Sales Drawing Number. PROPOSED STORE DESIGN FOR d 0 i Y =fi , Paladino+Company, Inc. Macerich "Offices include Open Office, Manager, Break Area and Restroomsm 1932 First Ave, Suite 200 11411 North Tatum Blvd. • Fire Sprinkler System; • Not Required fi Seattle, WA 98101 Phoenix, AZ 85028 Storage and Stock Rooms include Inventory, Electrical Room and Telco • Exterior Signage q '-' Tel: 206-522-7600 Tenant Coordinator: Karen Maynard ACCE551BLE PATH OF TRAVEL VERIZON WIRELE55 STORE Tel: 602-953-6526 Division 01 - General Reguirements Samples shall be submitted with full documentation in Contractor shall provide a binder for Client containing All studs and / or joists and accessories shall be Between Open Web Bar Joists: Secure with 16 or 18 08 70 00 —Hardware 09 3013—Ceramic Tiling sets of two (2); one (1) set will be returned. Provide maintenance manuals including operating instructions, galvanized with a minimum G-60 coating and of the gauge wire running diagonally or perpendicular to three (3) or more samples in each set where variations spare parts, warranties, inspection procedures, type, size, steel thickness and spacing shown on the insulation, spaced at 18 to 24 inches. Door hardware Iocksets and metal frames shall be Ceramic tile flooring shall be as specified in the Finish 0100 00 - General Requirements 9 in color, pattern or texture are noticeable; samples diagrams, safety, security and similar appropriate data plans. Studs, runners (track), bracing and bridging installed by Contractor as per Door Schedule or Schedule. Contractor shall provide allowances for should represent the average condition and the for each system or equipment item. shall be manufactured per ASTM Specification C-955. Over Suspended Ceilings: Install insulation with face Specifications. Hardware and lockset finishes shall be flooring material not specified on the drawings. GRUSKIN The Contractor shall provide all labor, materials, extreme range of variations. Sample submittals are All galvanized studs, joists and accessories, 14 ga. or contacting back of ceiling panels; butt insulation tightly silver, brushed chrome or aluminum unless noted Installation of ceramic tile flooring shall be performed appliances and equipment required to complete all far the review of color, texture, pattern and "kind". At final payment the Contractor shall deliver to Client a heavier, shall be formed from steel that conforms to together at edges to revert thermal leaks. work, etc., as shown on drawings, unless otherwise p Y g g p otherwise. in strict accordance with the flooring manufacturer's Contractor shall keep the returned samples at the complete release of all Sub-Contractors and suppliers the requirements of ASTM A-446 with a yield strength Instructions. 294 Morris Avenue Springfield,NJ 07081 ARCHITECTURE + DESIGN.P.C. specified. project site for quality control purposes. liens arising out of this contract, or receipts in full of 50 ksi as set forth in Section A3.1 of the AISI Provide full sound insulation batts in all new walls, full Installation of door hardware shall comply with the Tel: 973.376.441 1 Fax: 973.376.8989 covering all labor and materials for which a lien could "Specification for the Design of Cold-Formed Steel height. Support where necessary to prevent Building Code requirements and Accessibility Concrete slab surfaces shall be cleaned and made www.GruskinGroup.com NJ REG 0100-9869-14 The Contractor shall obtain and pay for all necessary Contractor shall maintain at the project site one (1) set be filed, or a bond satisfactory to the Client Structural Members", Latest Edition. movement or dislocation. requirements for door hardware and as Thisdocument and the Ideas and designs incorporated permits, licenses, inspections and other fees, both of prints to record and indicate: all locations of indemnifying him against an lien. q per smooth with leveling compound and substrate primer p Y g g Y manufacturer's installation instruction. prior to the installation. herein, o an Instrument of professional service,Is the permanent and temporary, necessary to execute his p property of GRUSKIN ARCHITECTURE+DESIGN,P.C.,and utilities, systems, pipes, conduits, duct work, cabling, Connections shall be accomplished with self-drilling In areas of extreme temperature changes, ceiling tiles Isnottobeused Inwholeorinpartforany other project work. without the written authorizationof GRUSKIN etc.; changes within the Construction Documents; and Division 02 - Existing Conditions screws or welding so that the connection meets or shall receive fiberglass insulation blankets in plenum Door handles, pulls, latches, locks and other operating Tile installer must examine substrate and ARCHITECTURE+DESIGN,P.C. any other items which may affect future construction, exceeds the design loads required at that connection. space (6 min. thick blankets shall be used). devices shall be installed 34 inches minimum and 48 environmental conditions under which ceramic tile is to All Rights Reserved The Contractor shall verify all conditions before renovations or repairs. This information shall be 02 40 00 -Demolition and Structure Moving inches maximum above the finished floor. be installed. ©2015GruskinArchitecture+Design,P.C. submitting his proposal. No allowance for extra submitted to the Owner and Client on a set of marked- Studs shall be installed seated squarely (within 1/16") 07 80 00 - Fire and Smoke Protection Kenneth A. Gruskin AIA charges will be permitted because of lack of up sepia transparencies upon completion of the against the web portion of the top and bottom tracks. Exit Devices for Means of Egress Doors: Comply with Maintain environmental conditions and knowledge of the conditions except as otherwise During all phases of demolition and construction, the g p Y protect work AL 5421 MT 2537 project. General Contractor shall maintain integrity of the Tracks shall rest on a continuous, uniform bearing Rated Assemblies, Separations & Fire Stopping: NFPA 101. Exit devices shall not require more than 15 during and after installation to comply with referenced AK 13167 NC 9961 specified in the Contract Documents. g Y surface. P g' AR 3811 ND 1666 structure to be demolished and adjacent areas to Ibf to release the latch. Locks shall not require use of a standards and manufacturer's printed Az 39209 NE A-3547 Any additional drawings required for mechanical, ke tool or special knowledge for operation. recommendations. CA C-29898 NH 2796 The Contractor shall check and verify all lines, levels remain with interior or exterior shoring, bracing, or Fire-rated drywall assemblies shall be constructed Y, p g p co ARC-400347 NJ Al09999 electrical or plumbing system design or for permit Gutting of steel framing members may be CT ARC NM Al 099 and dimensions shown on the drawings and will be support to prevent movement, settlement or collapse according to the diagrams on drawings and shall be 1, submission is the responsibility of the General accomplished with a saw or shear. Torch cutting of Panic Exit Devices: Listed and labeled b a testing and Comply with applicable arts of ANSI A108 series of DC ARC100723 NV 5521 held responsible for the correctness and setting out of of structure. Existing structure to remain shall be 2 or 3 hours as noted on Drawings. All rated walls Y 9 p Y PP P DE 0006261 NY 025528-1 NY p g Contractor to obtain and pay for. load bearing members is not permitted. Burning of inspecting agency acceptable to authorities having tile installation standards included under "American FL AR91629 OK o4895 his work. An omissions and/or discrepancies in the safed-off and protected from the elements at all times. shall extend from floor to underside of structure above. CA RA011075 0H 13761 Y p holes or cuts in any structural members in the field are jurisdiction, for panic protection, based on testing National Standard Institutes Specifications for the Hi AR 11489 OR 4899 drawings noted by the Contractor shall be brought to Contractor shall fully brace and otherwise protect all not permitted unless specifically approved by the according to UL 305. Installation of Ceramic Tile". IA 05713 PA RA-01 5432—B the Architect's attention prior to starting the work. Area of work shall be kept clean at all times. Concealed spaces within partitions, walls, floors, g ID AR-984459 PR 19965 work in progress until the building is completed. Architect. stairs, furring, pipe spaces, column enclosures, etc., IL 001-019152 RI 2666 The Contractor shall guarantee and maintain all Where the existingwork is to be cut underpinned shall be fire stopped with non-combustible material. Fire Exit Devices: Devices complying with NFPA 80 Comply with TCA installation methods and the IN AR10400066 SC 6834 g All Ian dimensions are given from face-of-stud to p Temporary bracing shall be provided and left in lace pp KS 4674 SD 11532 p g and/or shored Contractor shall provide all shoring, p y g p p that are listed and labeled by a testing and inspecting following: KY 5967 TN 101374 workmanship, materials and labor for a period of one r face-of-stud, face-of-masonry to face-of-masonry, or until work is permanently stabilized. agency acceptable to authorities having jurisdiction, for LA 5734 Tx 17680 year, or longer, as specified in the drawings and needling, bracing, wedging, and dry packing, and be Penetrations made in rated wall assemblies shall not g y P g J r ME ARC 2596 UT 5881358-0301 centerlines, unless noted otherwise. Written fire and panic protection, based on testing according to 1. Extend tile work into recesses and under or MD 11016 Vr 2572 specifications, from date of completion of the Contract responsible far the safety of the structure during these alter the performance of assembly and must meet the p p � g g MA 10635 VA 0401 011223 dimensions always supersede measured or scaled Vertical alignment (plumbness) of studs shall be within UL 305 and NFPA 252. behind e ui ment and fixtures to form a complete MI 1301552379 WA 10344 and make good any item proving defective during that dimensions- never measure drawings! Larger scale operations. 11960th (1/8" in 10'-0") of the span. Horizontal appropriate ASTM penetration requirements. equipment P term without an compensation. The Contractor shall covering without interruptions, obstructions, edges MN A-20 wi 9900-005 y P drawings shall take precedence over smaller scale alignment levelness of walls shall be within 11960th Mo A-2005029740 wv 3727 g p The Contractor shall repair and patch an areas that g { General Contractor shall patch and repair existing Door Closers for Means of Egress Doors: Comply with and corners without disrupting pattern or joint MS 3860 WY C-1967 submit this guarantee in writing to the Client on behalf drawings. p p Y 118" in 10'-0" of their respective lengths. p P g of himself and his Sub-Contractors. The Contractor's are altered or damaged during the process of the ( ) p g construction to maintain integrity of any fire protective NFPA 101. Door closers shall not require more than 30 alignments. Professional Seal: guarantee shall extend to match the guarantee for alteration. materials, coverings, assemblies or enclosures where Ibf to set door in motion and not more than 15 Ibf to g g Floors, walls, ceilings, partitions, beams, studs and Spacing of studs shall not be more than +/- 1/8 from open door to minimum required width. 2. Accurately form intersections and returns. products, systems and installations that have been an other arts of the building or remises which are the designed spacing provided that the cumulative disturbed by new work as called for in the drawings. Y p g P g P g p Perform cutting and drilling of tile without marring required to have guarantee lengths in excess of one cut, Any materials deemed as hazardous, such as but not 9 g 9 notched or altered in the installation of equipment error does not exceed the requirements of the Where the fire protective covering of a structural Surface Closers: Provide type of arm required for visible surfaces. Carefully grind cut edges of tile year, as indicated in the drawings and specifications. limited to, asbestos or lead paints, shall be removed, p g or systems shall be left in a safe structural condition. finishing materials. closer to be located on non-public side of door, The Contractor shall, at the request of the Client, encapsulated or left in its present condition as member is subject to damage from moving vehicles, p , unless abutting trim, finish or built-in items for straight GRUsxrrr These installations shall not cause a decrease in the otherwise indicated. aligned joints. Fit the closet to electrical outlets inspect all work, equipment and systems prior to the structural performance of any part or assembly to fall required by Federal, State and local codes. Contractor Concealed spaces within partitions walls, floors the handling of merchandise, or other activity, it shall g J Y � 4899 fixtures and other penetrations so that RING LD NJ expiration of the guarantee periods and repair all items shall utilize the appropriate techniques, procedures be protected from damage. piping, P below that which shall be the minimum required by and disposal methods as per standard practice, stairs, furring, pipe spaces, column enclosures, etc., All new doors shall be installed with lever handles. plates, collars, or covers overlap tile. ' found to be defective. these specifications and the building codes. p P P shall be fire stopped with non-combustible material. Federal, State and local codes. Any new Client demising or interior partitions shall be ati rated as required b code. An Provide floor stops for doors unless wall or other type 3. Jointing Patterns: Unless otherwise shown la OF The Contractor shall protect the Client from claims q y y penetration through an p Yp 9 i Y All equipment and furniture supplied by the Client (or All square corner beads shall be Everlast Corner stops are scheduled or indicated. Do not mount floor the in rid pattern. Alin joints when adjoining made under Workman's Compensation and Public Contractor shall remove all existing mechanical existing demising or other rated assembly wall must p g P 9 J 1 9 p others not covered elsewhere in these drawings) shall Beads by Phillips Manufacturing Company, 500-822- stops where the will impede Liability Acts which may arise under this Contract, comply with all applicable requirements for equipment, duct work, plumbing fixtures, piping 5055 or approved equal. retain the fire rated assembly, if one exists. stop/ stops are not appropriate,rraffic. Wr floor or tiles on floor, base,ter fields finlls d both directionsay out tile Consultant: whether by himself, by any Sub-Contractor or anyone systems, etc., not being reused. DO NOT JUST P provide accessibility and flame and smoke class requirements. ABANDON. All new work shall match ore equal the ratings, if an of holders. each space or on each wall area. Adjust to directly or indirectly employed by him. Certificates of q 9 r Yr Division 06 - Wood Plastics Composites the surroundingwork as appropriate. The Contractor minimize tile cutting. Provide uniform joint widths, Insurance shall be filed with the Client before starting If required upon completion of the project, Contrac#or � � ppro p Door frames shall have rubber silencers which are to unless otherwise shown. the job and shall be subject to the Client's approval. Contractor shall notify Architect immediately of any shall contact the Tenant and Architect if any areas are shall obtain a Certificate of Occupancy from the undocumented structural columns or conditions, 06 20 00 - Finish Carpentry uncovered or discovered that may require additional be installed after final painting. Color shall be as noted No extra work shall be paid for except on the order of Building Department. pipes,i etc.r Pon which are uncovered u removal of anal sis or clarification. on drawings. 4. Expansion Joints- Locate expansion joints and Y joints,t fill l other sealant e the Architect or Client. The Client will not be liable for Prior to start of work Contractor and Client shall have existing walls in the Client space, so drawings can be Cabinets and Built-ins: oj including control, revised as may be required to accommodate the Provide continuous weather-strip gasket on exterior contraction isolation joints, where indicated, or if any extra work not ordered by him. Y q Division 08 - � enings a pre-construction meeting to determine the exact uncovered as-built conditions. p doors and provide smoke, light, or sound gasket on not indicated, at spacings and locations sequencing and phasing of construction. Work shown Shop drawings for cabinetry and built-ins shall be interior doors where indicated or scheduled. Provide recommended in TCA "Handbook for Ceramic Tile Where connection is to be made to existing utilities, on drawings shall be phased such that each specific submitted to the Architect for review prior to 0810 00 - Doors and Frames noncorrosive fasteners for exterior applications and Installation" and approved b SDR. Pre are lv the Contractor shall make his own determination of The Contractor is cautioned to make continued fabrication. Contractor shall verify all field conditions pP pP Y P Job Name and Number. �, area shall be protected, demolished and completed. Y elsewhere as indicated. joints and apply sealants to comply with 2015-0131 J the location of such utilities. observations of the existing structure during the prior to fabrication. All cabinetry shall be installed level All doors shall be installed in 16 gauge hollow metal f r Y P Y J performance of his work. Should he become g g requirements of referenced standards and sealant Daily activities must be respected by the Contractor aware of an situation that requires further and plumb with no distortion; doors and drawers shall frames, unless otherwise noted. Frames shall be fully 08 80 00 —Glazinq manufacturer. Proposed Each Contractor shall provide and install all with the least amount of disturbance to the Client and y q fit openings and be properly aligned; all shims shall be welded frames and shall be shop primed, unless Ed miscellaneous steel, hanger supports, pipe racks, pipe building occupants. investigation or study, (such as abnormal concealed. otherwise noted. VERIZON anchors, etc., as necessary to support all equipment deflection) he shall notify the Architect Glazing at the front door and in windows within 24" of 5• Grout tile to comply with referenced installation Z installed under his contract. immediately. Cabinet Manufacturer and General Contractor shall be doors and in fixed panels larger than 9 sf with the standards, using grout materials indicated. STORE Due to the nature of the construction, it is essential Door frames shall have rubber silencers, which are to lowest edge Fess then 18" AFF shall be tempered and U that the Contractor or Client bring to the immediate responsible for the fabrication, installation and be installed after final painting. mus{ Upon completion of placement and grouting, clean all Substitutions for products specified herein shall be All demolition shall be in accordance with Building coordination of all appliances, cabinets electrical pass test requirements of CPSG - 16 CFR P P P g g, o attention of the Architect any variations, discrepancies pp r (LEED) L, permitted oniy with Architects or Clients approval. Code requirements and all local ordinances. plumbing and mechanical systems at areas with PART 1201. ceramic tile surfaces so they are free of foreign matter. or conditions that may affect the design, assembly and p g Y Exit doors shall be readily operable at all times from Leave finished installation clean and free of cracked, W Any requests for substitution by the Contractor shall project. the side which a egress is to be made. All exits shall be smooth construction of this ro ect. Since the Architect be submitted to the Architect or Client with the cannot detail every aspect of this project some Division 05 - Metals g All storefront glazing shall be tempered. chipped, broken, unbonded or otherwise defective the readily accessible and unobstructed at all times. work. appropriate literature, specifications, etc. The Fabricator shall determine if, and where fire retardant All glazing is tempered or safety, clear glass, unless conditions and details might need to be confirmed r warranty and performance of a substituted product or during construction by the Contractor. The Architect 05 40 00 -Cold- Metal Framing Formed materials are required by local, city or state codes. Interior doors shall be flush solid core wood doors. Job Address In material shall equal or exceed the original specified will not be held responsible for pre-existing conditions otherwise noted. When recommended by the manufacturer, apply a p p g Doors shall conform to NWMA 1.S 1-80 and AWI Type coat of neutral protective cleaner to completed the Washington Square Mall N product. In addition, the Contractor shall warrant that which could not have been known prior to Physical properties and allowable load capabilities of All cabinets shall have rubber bumpers at the top and SLC-5, and shall be "stave lumber". 9585 S.W. Washington CD substituted materials shall perform as specified. redesign,n bottom of all cabinet doors and sides of all drawers. All glass which is tempered shall bear the word walls and floors. g construction. Adjustments such as g , members shall be developed in accordance with AISI "tempered" in the corner of the glass and be visible Square Road engineering and details may need to be done at the "Specifications for the Design of Cold-Formed Steel Bumpers shall be mounted to doors or drawers. All doors 7'-0" high or smaller shall have 3 hinges (1 1/2 after installation. Contractor shall submit product data, including Portland, OR 97223 Contractor shall coordinate all aspects of the work Client's expense, as determined by the Architect. Structural Members", Latest Edition. pair) 4" x 4" with square edges. manufacturer's product sheet and flooring the sample Space R05-R07 U with: all Sub-Contractors and Suppliers engaged to All plastic laminate finishes shall be constructed Division 09 - Finishes to architect for review and approval prior to A perform work; the existing facilities/conditions, the 0170 0�0 - Execution and Closeout Requirements Walls shall be constructed of metal studs as noted on according to "Architectural Woodwork Quality All doors 8'-0" or higher shall have 4 hinges (2 pair) 4" installation. Z Owner and Client; and separate Contractors, if any. drawings at 16" o.c. 20 gauge minimum. Standards" by AVIA, Premium grade. x 4" with square edges. Finish shall be Satin Chrome DrawingTlde: U Each Sub-Contractor shall verify and review proposed D The Contractor shall notify the Architect/ Engineer and Supplementary framing, runners, furring, blocking and Plated. 09� 20 00 - Plaster and Gypsum Board Continued on Sheet Af.2 and/or existing conditions within the extent of his work All plastic laminate countertops shall have flat edges. and shall inform the Contractor of any work that will be Clients representative to perform a preliminary final bracing shall be installed as required at openings and p pGeneral Notes and required by others for the completion of his work. inspection. A punch list outlining work to be corrected, when other work cannot be adequately supported on Norton Series 6931-24 Electro-Magnetic Door Holder Drywall: Specifications finished, performed or completed shall be submitted gypsum board alone. Division 07 - Thermal and Moisture Protection shall be installed at 3 hour metal door. Holder shall be cu by the Contractor. All work outlined on the initial punch wired to release door as outlined in engineering Drywall construction shall be as per Building Code C4 Each Contractor shall pertorrn all excavation required list shall be completed by the Contractor prior to the Metal studs and joists shall be manufactured by 07 20 00 - Thermal Protection specifications for Halon Agent Extinguishing System. requirements for Gypsum Board Construction. 3 for the installation of his work and for connections. final inspection and before the project will be Marino=are Industries Corp., 400 Metuchen Road, Drawn By. North Each Contractor shall do all necessary backfilling, accepted. After all requirements preparatory to the South Plainfield, NJ 07080, (800) 627-4661, or Thermal barrier shall be in accordance with Building Weatherstripping and sill protection shall be installed Interior walls shall be finished with 518" gypsum board, JL Arrow tamping, grading and repairing or replacing of sod g unless noted otherwise on drawings tv ' final inspection have been completed, the Contractor approved equal. See plans for sizes and locations. Code requirements for thermal protection and local at all doors where "special seals" are noted on Door g and Checked By. sidewalks, blacktop access and streets which he s ecifications. KG 0 disturbs. shall notify the Architect/ Engineer to perform a final regulations. Schedule. Contractor shall install all seals and sill p Date Issued For A inspection. If all of the work has been completed Metal studs must be listed by an approved testing and protection so as not to interfere with the operation of Client: 12/24/15 Qf including punch-list items from earlier inspections and listing agency (ICBG ES) and must be installed per the Installation of insulations shall be in accordance with the door or closer mechanism. A sealing system that Interior fire rated walls shall be finished with 518" Type Landlord: 12/24/15 Shop drawings will be reviewed only when three (3) x sum board full height to bottom of structure Permit: 12/24/15 no further corrections are required, then the Architect/ listing and manufacturers installation instructions, as manufacturer's instructions NAIMA includes sill protection, is designed for use in rooms gypsum 9 copies are submitted to the Architect bearing rr equipped with halon and has an a Contractor's 'approved' stamp. In addition, the �oC{er shall recommend final acceptance of the per code. Recommendations for Installation in Residential andapproved fire rating above. Bid- Contractor's j Other Light-Frame Construction - Fiber Glass Building equal to the rating of the door shall be installed. construction: W Contractor shall note and encircle on shop drawings Provide 3 5/8" metal stud diagonal bracing on all walls Insulation" and manufacturer's instructions. All gypsum board shall be securely fastened using Revision Issue:. Date Description any variation from the Construction Documents Contractor shall be responsible for the start-up of all as required by Code. Contractor and Manufacturer shall determine drywall screws. , caused by any reason including standard shop equipment furnished installed or serviced under this appropriate frame size and lass thickness for new Z practices. Review of the shop drawings will be general ' Surface application: Apply insulation directly to surfaceg o p p g g contract. Contractor shall verify that all equipment, All full height partitions shall be wedged lightly to with appropriate spindle or prong-type anchors or windows in Tenant's space. Glass shall be installed Contractor shall coordinate all work with Plumbing, to determine conformance with the design concept of Lo electrical systems and appliances are functional and ceiling structure above. All other walls shall be follow adhesive manufacturer's recommendations for and leveled on appropriate type shims. All screws Electrical and Mechanical system Contractor(s) in = the project and shall not relieve the Contractor of operational and that all plumbing and HVAC constructed u to 6" above ceiling rid unless shall be set level and flush with frame. order to locate equipment, ducts and registers, light Q responsibility for accuracy of: shop drawings, as-built P p g p g g surface preparation and adhesive pattern. 3 equipment is operating quietly send free from vibration. otherwise noted. Any additional bracing shall be housings, waste lines, etc. and field measurements, quantities; and for proper provided by the Framing Contractor. Between Furring Strips Hat Channels and Z-Shaped 08 40 00 - Entrances, Storefronts and Curtain Walls fittings or construction of work required by the ' Non-combustible fire stops shall be installed at I L3 Final Cleaning: At the time of project close-out, the Furring: Install insulation between furring members- p oQ Contract Documents but not indicated on shop Contractor shall thoroughly clean and read the Contractor shall coordinate all required blocking for openings around vents cabling, �,� drawings. Review of shop drawings shall not be g y Y q 9 use fastening system recommended by furring strip At interior mall locations — Storefront glazing shall g g, pipes and ducts at �N Clients space for occupancy. This shall, at minimum, furniture, shelving and cabinets, etc., with the manufacturer. be 1/2" thick clear, tempered, frameless glass ceiling and floor levels. Z 1- construed as approving departures from contract ' ' „o include all fixtures, equipment, walls, floors, ceilings, appropriate vendor. Provide two (2) rows minimum 8" centered in 1 1/2" wide x 6" high aluminum storefront Ed requirements or as acceptance of responsibility by the hardware light fixtures replacement of burned out high, 20 gauge metal strapping on studs at all cabinet Draftsto in and fire blocking 1:3_J Owner, Client and / or Architect. g P g g g pp g Between Metal Studs, Rafters, and Joists: Friction fit base. It is the glass fabricator's responsibility to verify with the Building Code. g materials shall comply lamps, removal of non-permanent protection and walls and where noted on plans. insulation between framing members after cover in field the exact length of glazing required. 9 WLJ Z labels, touch-up of any minor finish damage, and material has been installed on one side of the cavity. 3" cleaning or replacement of mechanical system filters. Noncombustible fire stops shall be installed at All walls shall have a LEVEL 5 finish. Number. � � Damage to any finish, surface equipment or object openings around vents, cabling, pipes and ducts at caused during cleaning shall be repaired or replaced ceiling and floor levels. C) by the Contractor at his own cost. 1 ICD ■ ru 10F 31 Continued from Sheet Al.I Install rubber wall bases in lengths as long as practical Do not install wallcovering until a lighting level of not Shop drawings shall be prepared by Signage shall be Clear with Black lettering. All cabinets shall be All wiring and controls shall be installed in accordance drawings. One of the above circuits shall be part of the without gaps at seams and with tops of adjacent less than 15 foot - candles (160 lux) is provided on the Contractor and submitted to the Architect for review installed as per ADA guidelines. with NFPA 70, latest edition. emergency lighting system. 09 50 00—Ceilings pieces aligned. surfaces to receive wall covering. prior to signage fabrication. Division 22 - Plumbing Entire system shall be grounded as per Electrical The color and design of lettering, arrows and other Tightly adhere rubber wall bases to substrate Provide continuous ventilation during installation and Signage Contractor shall submit all signage to the Code. symbols on the exit sign shall be in high contrast with Suspended Ceilings: throughout length of each piece, with base in for not less than six days for full drying or curing. applicable building department for approval, if 22 00 00 — Plumbing their background. Words on the sign shall be in block GRUSKIN continuous contact with horizontal and vertical required. Electric outlets within 6-0" of a sink, in Janitor's letters, 6" in height with a stroke of not less than 3/4". ARCHITECTURE General Suspended Ceiling notes: substrates. Verify that colors and patterns of wall coverings are Closets, Bathrooms and outdoors shall be protected 294 Morris Avenue Springfield,N Plumbing Contractor shall install new plumbing as j 07081 those specified before beginning installation. Match Interior directional signage shall be as per Verizon by a ground fault circuit interrupter: 'GFI'. Exit signs shall be internally or externally illuminated Tel: 973.376.4411 Fax: 973.376.8989 Suspended ceiling systems shall be per Building Code Contractor shall submit product data, includ in shown on Plumbing Drawings. All plumbing fixtures www.GruskinGroup.com NIREGGIOG-9869-14 p 9 pattern 72 inches (1830 mm) above finish floor. Wireless standards, by two electrical lamps or shall be of an approved self- requirements for Suspended Ceiling. manufacturer's product sheet, and flooring tile sample and accessories shall be accessible. Contractor shall verify all conditions in the field prior to luminous type. When the luminance on the face of an This document and the Ideas and designs Incorporated to architect for review and approval prior to Install seams vertical and plumb at least 6 inches (150 Provide a readily visible durable sign posted on the bidding and installation. Remove and/or relocate exit sign is from an external source it shall have an herein,as an Instrument of professional service,Is the New suspended acoustic the ceiling rids and heights Plumbing system design and installation shall be in property of GRUSKIN ARCHITECTURE+DESIGN,P.C.,and p g g g installation. mm) from outside corners and 3 inches (75 mm) from egress side on or adjacent to the main entry door existing equipment as necessary to accommodate intensity of not less than 50 foot candles from either Is not to be used In whole or In part for any other project shall be as noted on Reflected Ceiling Plan. inside corners. No horizontal seams. statin "THIS DOOR TO REMAIN UNLOCKED accordance with the Plumbing Code. All appliances, without the written authorization of GRUSKIN g ,r plumbing fixtures and general equipment shall be new conditions. lamp. Internally illuminated signs shall provide ARCHITECTURE+DESIGN,P.C. 09 6516 - Resilient Sheet Flooring WHEN BUILDING IS OCCUPIED. The sign shall be p g g q p AIIRIghtsReserved installed according to manufacturers specifications equivalent luminance, (50 Lux). New ceiling types and styles shall be as noted on the Trim edges for color uniformity, pattern match, and in letters 1 inch high on a contrasting background. g p Where connection is to be made to existing ©2015GruskinArchitecture+Design,P.C. Finish Schedule and Interior Finishes. and installation instructions. All controls shall be the Contractor shall make his own Kenneth A. Gruskin AIA Vinyl sheet flooring shall be as specified in the Finish tight closure at seams and edges. Overlap and accessible. equipment, Division 2$ - Electronic Safetu and Security Schedule. Installation of vinyl sheet flooring shall double - cut seams. 10 2$ 00 - Restroom Accessories: determination of the location of such connection. AL 5421 MT 2537 Suspended ceiling and framing systems shall be comply with manufacturer's written instructions. AK 13167 NC 9961 designed to resist a lateral force of 20% of the weight Disinfect new potable water piping. 20 30 00 - Electronic Detection and Alarm AR 3811 ND 1666 of the ceiling assembly and an loads tributary to the Remove excess adhesive at finished seams, Accessories for Restrooms shall be by Bobrick HVAC control wiring shall be by Electrical Contractor. Az 39209 NE A-3547 g Y Y y Concrete slab surfaces shall be cleaned and made perimeter edges, and adjacent surfaces. Use cleaning Washroom Equipment, Inc., (818) 982-9600, or Control equipment and wiring diagrams to be CA C-29898 NH 2796 system. For the purposes of determining the lateral All sanitary and water lines must be tested for leaks. Contractor shall furnish and install all labor, materials Co ARC-400347 NJ Al 09999 smooth with leveling compound and substrate primer methods recommended by wall covering approved equal. Units shall be installed plumb and furnished to the Electrical Contractor by the HVAC CT 9613 NM 004168 force and where partitions are not connected to the Use 150# hydrostatic pressure for domestic water and equipment re uired for a complete modification DC ARC100723 NV 5521 ceiling system, prior to the installation. manufacturer. level, be firmly anchored, and be in accordance with lines, and electronic monitoring for as piping. Contractor. q p g y g 9 p p g. and extension of an existing fire alarms stem if DE 0006261 NY 025528-1 NY the manufacturers instructions. Y g Y FL AR91629 OK 04895 Prepare substrate(s) in accordance with Contractor shall provide wall covering sample for Temporary electric service shall be provided for currently present in the building or if required by any GA RAD11075 OH 13761 Seismic Design Categories for minimal weight design- r , g p Insulation to be ASTM E-84 or NFiPA 255 flame & p other applicable code or an of the new work. All HI AR 11489 oR 4899 g g g g manufacturers instructions. Install building expansion architects review and approval prior to installation. ■ Horizontal Grab bars B-6806.99 Series; construction by Electrical Contractor. pP Y IA 05713 PA RA-015432-B • Categories D, E & F- 16 lbs/LF. joint covering system prior to installing resilient sheet 36" and 42" smoke spread approved. equipment shall be U.L. listed and shall bear the U.L. ID AR-984459 PR 19965 J g Y p g IL 001-019152 RI 2666 flooring. 09 90 00 - Painting and Coating ■ Vertical Grab bars B-6806.99 Series; 18" All electrical devices and cover plates shall be gray, label and be compatible with existing system. The IN AR10400066 SC 6834 The followingbracing method may be employed- g A Tenant supplied bottled water cooler shall be installed system shall conform to NFPA codes 70 72 Ks 4674 SD 11532 g Y ■ Toilet Paper Dispenser B-76867(for Vilest Area) including all plug molds, telephone/data jacks Y KY 5967 TN 101374 provided. 90A and 101 and shall meet the requirements of all LA 5734 Tx 17680 Establish layout to use as few seams as possible. Finishes & Painting: Paper Towel Dispenser B-2620 (for West Area) switches and outlets except for the following: outlets , , ME ARC 2596 UT 5881358-0301 A. Lateral support may be provided by four wires of Make short seams rather than long seams as Soap Dispenser B-2112 and cover plates on walls and on exposed other codes and standards currently adopted by the MD 11016 VT 2572 minimum No. 12 gauge splayed in four directions appropriate. Place seams in low traffic areas when ■ Seat Cover Dispenser B-4221 Bottleless water cooler in lieu of a drinking fountain ceilings/soffits painted White shall be White, outlets on authorities having jurisdiction. MA 10635 VA 0401 011223 90 degrees apartand connected to the main Application of controlled interior finishes shall be in shall be supplied by Client, and shall be installed with MI 1301052379 WA 10344 possible. Avoid cross seams and utilize only seam accordance with Building Code requirements for Mirror B-165 2436 water supply line by Plumbing Contractor as indicated walls painted Midsummer Night or Black shall be black Wiring shall by in accordance with Article 760 of the Mo A-200502974D WV 44326 WI 3900-005 runner within 2" of the cross runner and to the 27 lengths as they blend better with sheet flooring ■ Toilet Partitions Duraline Series 1080 and cover plates shall be painted Midsummer Night or Ms 3860 WY C-1967 structure above at an angle not exceeding 45 Interior Finishes. on drawings. Color shall be white. Water cooler shall National Electrical Code and all local codes that apply. g g material. floor mounted Black. r Professional Seal: degrees from the lane of the ceiling. Lateral be accessible. Manufacturer shall be as per Client The Electrical Contractor is responsible for assuring g p g� Color: P-886 p g Classes of materials based upon their flame spread Regional direction. "ganged" that conduit size and wire quantity, size support points shall be placed 12 feet o.c. in each Evenly comb adhesive perpendicular to length of Grey Grit g In all locations with ganged switches, ganged q y, , and type are characteristics shall be as set forth in NFPA 13 current direction with the first point within 6 feet from sheet using proper trowel for conditions. edition ( ristic Hat and Coat Hook B-682 (for West Area) See plumbing drawings far additional notes and switchplates shall be used. suitable for the equipment supplied. All wiring shall be each wall. ■ Single Robe Hook B-671 (for West Area) p g g within EMT raceway system. Flash Cove: Apply cove stick where wall meets the specifications. Panelboards shall be equipped with typewritten A B. Allowance shall be made for lateral movement of The maximum flame spread classification of finish The Fire Alarm Equipment Su lier shall furnish wiring HA:G sKIN floor and install cap molding on the wall where the materials used on interior walls and ceilings shall not Both Hat Hook and single Robe Hook shall be indexes. pp g a the system. Main runners and cross runners may flooringends. Adhere sheet flooringflash cove to wall mounted on all restroom doors inside the room). If Division 23 - Heating and Air Conditioning diagrams detailing device and control panel 4899 be attached at two adjacent walls with clearance and hand roll. Weld inside and outside cove corners. exceed that set forth in NFPA 13. there are multi-fixture restrooms, the hooks shall I be All li ht switches shall be thea appropriate riate size for the terminations to the Electrical Contractor for installation �/ � g pp p SgUNGFIELD,NJ between the wall and the runners maintained at mounted to the inside face of the partition door(s). The 23 00 00 —Heating and Air Conditioning load which is shown. If one switch will not be guidance. 11 the other two walls. The smoke density of materials shall be no greater � Contractor shall submit product data including Bobrick B-671 Single Robe Hook should be mounted sufficient or one does not exist the Electrical ; ' i�' manufacturer's product sheet and sheet flooring than ay i when tested in accordance with NFPA 13 in at 46" AFF per ADA requirements. The B-682 Hat and Contractor shall determine the correct quantity of Contractor shall install or modify any existing fire ` OF t�� p � g the way intended for use. p q Mechanical contractor shall install new Mechanical q y C. Discontinuous ends of cross runners shall be sample to architect for review and approval prior to Coat Hook should be mounted at 68" AFF. system as shown on Mechanical Drawings. switches required by the load. alarms fire-detection systems, manual alarm boxes Consultant vertically supported within 8" of such installation. and signaling systems to comply with the Building discontinuities as may occur where the ceilingis Decorative materials shall be maintained in a flame- Code if required. An existing fire alarm systems y retardant condition. Division 21 - Fire Suppression Mechanical system design and installation shall be in Subpanels and junction boxes located on structural q y g Y disrupted by a wall. 09 68 00 —Carpeting accordance with the Mechanical Code and all local columns shall be relocated to electrical or storage shall be incorporated into new spaces and/or modified All interior finishes shall be as per Finish Schedule codes and ordinances. Mechanical system design and closets so they will not be visible from any office area. as required. D. Lighting fixtures and air diffusers shall be p 21 10 00 -Water-Based Fire-Suppression Systems Carpeting materials and finishes shall be as specified and Interior Finishes. layout shall be the responsibility of the mechanical supported directly by wires to the structure above. in the Finish Schedule. Contractor shall provide contractor. Contractor shall coordinate telephone computer Sprinkler system tamper and water flow switches shall g P Paint and finishes shall be applied in accordance with Fire Sprinkler Systems network and electrical connections/re uirements to be provided and installed by the Sprinkler Contractor allowances for flooring material not specified on the pp q and shall be wired to, and connected to the fire alarm cu Exception: drawings. the manufacturer's instructions. Contractor shall use All mechanical equipment and wiring shall be installed partition system with vendor. applicators and techniques best suited for the All items shall be as per Building Code and all local in accordance with manufacturer' system by the Electrical Contractor. s installation 1. Recessed lighting fixtures not over 56 pounds in codes and ordinances. Contractor shall install and wire electrical service All preparatory work shall be performed in strict materials and surfaces to which they are being instructions and with a minimum clearance to weight, and suspended and pendant hung fixtures not throu h ower o An approved audible and visual alarm device shall be N accordance with the flooring manufacturer's applied. combustibles for which the equipment has been 9 powerpoles les and wall feeds to partition system. N over 20 pounds in weight, may be supported and instructions. Prepare all new and existing substrates Fire Suppression Contractor shall furnish a new tested, as specified by manufacturer, or in accordance connected to the sprinkler system and shall be Job Name and Number. 2015-0131 attached directly to the ceiling system runners by a and install all carpet and accessories as per sprinkler system or modify the existing sprinkler with Standard Installation Clearances. All mechanical Telephone system design and installation of jacks, activated by water flow. J p p Surfaces shall be prepared and cleaned in strict positive attachment, such as screws or bolts. Two (2) manufacturer's directions. accordance with paint manufacturer's instructions. In system to provide proper coverage to all Tenant areas equipment and controls shall be accessible. equipment and cabling shall be wired and installed by Proposed #12 slack wires are required for support at recessed in accordance with NFPA 13. vendor selected by Verizon Wireless. Vendor shall Continued on Sheet A1.3 addition walls shall be spackled and sanded smooth V E R I�0 N a light fixtures. Air diffusers which weigh not more than Concrete slab surfaces shall be cleaned and made Contractor shall furnish control wiring diagrams to also install and wire telephone service through prior to painting. Additional coats of paint shall be 9 g Z 20 pounds, and which receive no tributary loading smooth with leveling compound and substrate primer applied when undercoats stains or other conditions All sprinkler heads in ACT-1 type ceiling shall be fully Electrical Contractor. Control wiring by Electrical powerpoles and wall feeds to partition system. from ductwork may be positively attached to and prior to the installation. concealed and centered in 2' x 2' grid. Finish shall be Contractor. STORE supported by the ceiling runners. p show through final paint coat. white powder coat finish. All sprinkler heads in ACT-2 Computer network system design, cabling and 13 type ceiling shall be fully concealed and centered in 2' installation shall be installed b vendor selected b (LEED) Do not bend suspended ceiling hanging wire at point Carpet Tile shall be installed wall to wall except where Drywall shall receive one coat of drywall primer-sealer x 2' rid. Finish shall be black powder coat finish. All Restrooms shall have a ceiling exhaust fan vented to Y Y A p g g g p indicated on the plans. Carpet Tile edges shall be g p the exterior. Verizon Wireless. Vendor shall also install and wire p p 9 prior to finish paint application. All wood required to be of attachment or at obstructing material or equipment, sprinkler heads in ACT-3 type ceiling shall be either computer network cabling through powerpoles and �_ except at lightweight items not exceeding 3E4" installed tightly together to form seams without gaps, job-painted shall be primed and sealed. concealed or semi-recessed. Finish shall be white wall feeds to partition system. Where cabling ' diameter. fit neatly to walls, columns, registers, adjacent flooring, powder coat finish. DO NOT FIELD PAINT. Verify all conditions in the field prior to bidding and P Y g must M abutting surfaces, etc. Installation shall be made to job Work of other trades shall be rotected. An dams e p installation. Remove and/or relocate existing penetrate walls to connect with equipment, a cableway p Y g lob Address site conditions and dimensions. Remove adhesive equipment as necessary to accommodate new with a removable plastic grommet shall be supplied. Seismic Requirements: caused by painting shall be corrected by cleaning, Sprinkler head layout shown on the Reflected Ceiling y Washington Square Mall promptly from the face of the carpet. repairing or replacing, and refinishing, as directed by conditions. All mechanical equipment and wiring shall g q �' Plan is for diagrammatic purposes only and is not be installed in accordance with manufacturer's Security system shall be designed and installed by 9585 S.W. Washington rr „ « „ "F": r the Architect. Category "D", "E"2 & F . Seismic suspended ceiling meant to represent an engineered system. Vendor selected b Verizon Wireless. Vendor shall S Where carpet meets dissimilar floor surface, proper installation instructions and with a minimum clearance Y quare Road shall be Armstrong Seismic RX Suspended System for coordinate work with Contractor. Z er rr rr edge molding shall be used. Install carpet edge Contractor shall provide a minimum of one (1) gallon to combustibles for which the equipment has been Portland, OR 97223 Category "D", "E", & F with BERG-2 Clip. Refer to moldings where edge of carpet is exposed and at Contractor shall supply all caps. If minimum quantity is tested as specified b manufacturer, or in accordance Space R05-R07 rr ,r g g p p of each calor paint to CI ient for future touchup work. � p Y p o Seismic Ceiling Notes on Reflected Ceiling Plan for required for orders, extra quantity shall be given to See Electrical Drawings for additional notes and transitions to other floor covering. Edge moldings shall with Standard Installation Clearances. All mechanical 9 seismic ceiling requirements. Installation of seismic be securely anchored to substrate. Client for future use. equipment and controls shall be accessible. p Z ceiling shall follow the manufacturer's instructions, ICC Division 10 - Specialties specifications. DrawingTitle: L) ESR-1308 and CISCA recommendations for areas Fire Suppression Contractor shall furnish sealed shop Transition moldings shall be used between carpets Where connection is to be made to existing 26 50 00 - Lighting subject to light to severe seismic activity. 10 14 00 - Signage & Neon: drawings of the sprinkler system prepared by a PE for V) and other flooring as shown on the drawings. equipment, the Contractor shall make his own General Notes and approval by the Building Department and Fire Marshall determination of the location of such connection. Electrical Contractor shall install new electrical work Specifications 09 6513 - Resilient Wall Base All signage shall be supplied and installed b Verizon for submission for permit, if required. All designs to be p It is the Contractor's responsibility to feather in g pp Y based on hydraulic calculations. as shown on Electrical Drawings flashing a minimum of 24 all around high point to Wireless Signage Contractor. Contractor shall Y Contractor shall adjust all supply and return registers Z Rubber Wall Base: keep a smooth and flush transition. coordinate and provide the required electrical and ducts as required providing proper ventilation, All lighting fixtures shall be as specified on the Lighting 3 connections and supports/blocking for signage. The Contractor shall employ the Landlord designated heating and cooling to all Tenant spaces. Actual Fixture Key on the Reflected Ceiling Plan. Drawn By. North Rubber wall bases shall be as specified in the Finish Contractor shall provide flooring the sample for Signage Contractor shall be responsible to field verify 0 Contractor to perform all sprinkler modifications. mechanical system design layout and equipment 1L Arrow: N Schedule. Contractor shall provide allowances for architect's review and approval prior to installation. all conditions and coordinate mounting details as System modifications shall be scheduled in advance specifications shall be the responsibility of the All lights shall be located and switched as indicated on ChecketlBy. flooring material not specified on the drawings. required. with the Landlords Field Representative. The sprinkler Mechanical Contractor. Drawings. KG system shall be full charged and operational when Date Issued For 09 72 00 —li';fall Coverings Y Y g p Client-.-..--. 12/24/15 Signage Contractor shall be responsible to verify all the Contractor is off the site. Lockingthermostat covers shall be supplied and Building standard average level of lighting throughout Landlord: 12/24/15 Store rubber wall base products and installation g g P Y conditions which may affect the installation of signage, pp g g g g g Permit: 12/24/15 I materials in dry spaces protected from the weather, Wall coverings shall be as specified in the Finish Y installed by General Contractor, unless otherwise shall be as required by code. J with ambient temperatures maintained within range Schedule. Installation of wall coverings shall comply and the signage itself. Any field or proposed design 21 20 00 - Fire-Extinguishing Systems directed by Client. Bid: recommended by manufacturer. with manufacturer's written instructions for surface conditions which may require modification or Quantity of heads on track lights shall be as shown on Construction: W relocation of si nage,e, or an related elements, shall All items shall be as er Buildin Code and all local Revision Issue: Q preparation. g g Y P g Telco Room shall have a thermostatically controlled drawings unless otherwise determined by the No, Date Description Prepare substrates according to manufacturer's be brought to the Architect's attention immediately, codes and ordinances. exhaust fan or optional wall mounted, minimum one Architect and Verizon Wireless' Project Manager. Z written instructions to ensure adhesion of rubber wall Prepare substrates to achieve a smooth, dry, clean prior to fabrication. Signage Contractor shall review ton AC unit with preset thermostat which must run 24 base. Fill cracks, holes, and depressions in surface free of flaking, unsound coatings, cracks, and Architect's proposed signage specifications and Portable fire extinguishers shall be installed as hours to cool mechanical equipment. Unit shall be See Electrical Drawings for additional notes and Z substrates with trowelable leveling and patching defects. design, and bring to attention any discrepancies or required by NFPA 10, or as required by local officials. manufactured by Mitsubishi, Liebert, Sanyo, or specifications. compound and remove bumps and ridges to produce alternatives which may result in savings to the Client, Extinguishers shall bare the label of an approved approved equal. 3 a uniform and smooth substrate. Prime or treat areas susceptible to pigment bleeding, elimination of problematic conditions which may arise agency and be of an approved type. Fire extinguishers p pig g 26 53 00 — Emergency Exit Signs. M and prime new gypsum board with primer in the present or future, provide superior performance, shall have a rating of 2A. Contractor shall determine See mechanical drawings for additional notes and � 3 Installation of rubber wall bases shall comply with recommended by wall covering manufacturer. provide reduced maintenance and enhance visibility of the quantity, location, type, etc., for conformance with specifications, Exit signs shall be provided in accordance with the NQ manufacturer's written instructions for installing signage. applicable codes. Building Code and all local ordinances Z resilient base. Remove switchplates, wall plates, and surface- Division 26 - Electrical LDo Artwork required for signage fabrication shall be Wall mounted fire extinguishers shall be provided and W J mounted fixtures in areas where wallcovering is to be provided b Verizon Wireless. Sizes as indicated on installed b Client unless otherwise directed. Exits shall be illuminated at any time the building is oQ Apply rubber bases to walls, columns, pilasters, applied. Upon completion of wallcovering installation p y Y 2600 00 - Electrical occupied with light having intensity of not less than 1 z casework and cabinets in toe spaces, and other in each space or area, reinstall items removed using drawings. footcandle at floor level. Ld 3; permanent fixtures in rooms and areas where base is workmen skilled in the trades involved. Recessed fire extinguisher cabinet shall be Cameo X— required. Signage Contractor shall submit and pay for all Series Model #AL-C2409-R by Larsen's Electrical Contractor shall install new electrical work Drawing Number: q required permits, tests and inspection certificates. Manufacturing, Co., (800) 527-7367, or approved as shown on Electrical Drawings. Exit signs shall be electronically illuminated and Z¢ equal. Trim Projection shall be Flat; Trim and Door energized from separate circuits. See electrical o� �o Material shall be Clear Anodized Aluminum; Bubble >If) A1, 2 10 �, --- ---- -- --- -- -- - 2 OF 31 Continued from Sheet A1.2 Grab bars and receptacles shall be mounted as 0 The lamp shall be a xenon strobe type or GRI Green Label Plus program. indicated in plans /diagrams on drawings. equivalent. Metal Studs & Framinq: Carpet and pad adhesives shall have a maximum Addition - Accessibility Guidelines: * Lavatories and Mirrors: The color shall be clear or nominal white. Metal studs or steel framing shall include recycled VOC content of 50g/L All equipment, accessories and work shall be � content_ GRUSKIN Lavatories shall be mounted with the rim or counter The maximum pulse duration shall be two The contractor shall complete the Materials Submittal performed in accordance with all Federal, State and surface no higher than 34" above the finished floor. tenths of one second with a maximum duty The contractor shall provide complete `Materials Form for all flooring and carpet products. A copy of ARCHITECTURE local codes with respect to handicap accessibility, and Provide a clearance of at least 29" above the finished cycle of 40%. The pulse duration is defined Submittal Forms' for all steel materials used on the the form can be found in the LEED prototype green 294 Morris Avenue Springfield,NI 07081 with the International Code Council and the American floor to the bottom of the apron as indicated on as the time interval between initial and final project. Including, but not limited to, metal studs, specifications. Tel: 973.376.4411 Fax: 973.376.8989 National Standards Institute (ICC/ANSI A117.1) or drawings. points of 10% of maximum signal. framing, bracing, ect. A copy of the form can be found www.GruskinGi•oup.com NJREG0100-9869-14 Americans with Disability Act (ADA). The more on the Green Specifications Addendum Sheet. The contractor shall provide cut sheets or other This document and the ideas and designs incorporated restrictive code shall apply. Knee and toe clearances shall be as indicated on The intensity level shall be a minimum of 75 documentation of each flooring product, hi hli htin herein, o an Instrument of professional service,Is the highlighting g property of GRUSKIN ARCHITECTURE+DESIGN,P.C.,and drawings. candela. The contractor shall provide product information for recycled content information. Is not to be used In whole or In part for any other project * Daors and Hardware: without the written authorization of GRUSKIN each metal/framing material highlighting the post- ARCHITECTURE+DESIGN,P.C. Hot water and drain pipes under lavatories shall be ■ The flash rate shall be a minimum of 1 Hz consumer and post-industrial recycled content. All hard surface flooring shall be certified as compliant All Rights Reserved Doorways shall have a minimum clear opening of 32", insulated or otherwise configured to protect against and a maximum of 3 Hz. with Floor Score standards by an independent third- ©2015GruskinArchitecture+Design,P.C. with the door opened 90 degrees, and measured contact. There shall be no sharp or abrasive surfaces Doors and Glazinq: party Kenneth A. Gruekln AIA between the face of the door and the opposite stop. ■ The appliance shall be laced 80" above the AL 5421 MT 2537 pP p� under lavatories. pp � p highest floor level within the space or 6" Cabinets and Built-ins: AK 13167 NC 9961 The contractor shall also provide manufacturers ND 1666 AR 3811 Threshold shall be 1/2" maximum total height with 1/4" Faucet controls shall be operable with one hand and belowthe ceiling, whichever is lower. information for each wood door highlighting the post- Az 3811 NE 1666 maximum vertical change at edge. Change in level shall not require tight grasping, pinching, or twisting of consumer and/or post-industrial recycled content. Adhesives used for wood substrates shall have a CA C-29898 NH 2796 9999 between 1/4" and 1/2" shall be leveled with sloe no ■ In eneral no lace in an room ors ace p y CT ARC-400347 NJ AI 168 p the wrist. The force required to activate the faucet general, p Y p maximum VOC content of 30glL cr 9613 NM 004168 greater than 1:2. shall be no more than 5 foot pounds. Lever-operated, required to have a visual signal appliance, DC ARC100723 NV 5521 Smoking areas will be at least 30 from doors, DE 0006261 NY 025528-1 NY and electronically controlled mechanisms shall be more than 50'-0" from the signal. In FL AR91629 OK a4895 Door closers shall have sweepperiods adjusted so push-type y operable windows and outdoor air intakes. Provide P J are acceptable examples of acceptable designs. If large rooms and spaces exceeding 100'-0" cA RA011075 off 13761 signage at front entrance if required by landlord. The contractor shall provide manufacturer's that it will take a door a minimum of three seconds to self-closing valves are used, the faucet shall remain across, without obstructions 6'-0" above the Hi AR 11489 oR 4899 information for each wood cabinet and/or built-in IA 05713 PA RA-015432-B move from an open position of 70 de rees to a finished floor such as auditoriums devices ID AR-984459 PR 19965 p p g open for at least 10 seconds. ( All windows and doors being replaced by contractor highlighting the post-consumer an/or post-industrial IL 001-019152 RI 2666 position where the leading edge of the door is three may be placed around the perimeter, spaced recycled content. IN AR10400066 SC 6834 inches from the jamb. at a maximum of 100'-0" apart, in lieu of shall be specified with air leakage that does not Y KS 4674 SD 11532 J Mirrors shall be mounted with the bottom edge of the p exceed 1.0 cfm/s.f. for glazed swing doors and 0.4 KY 5967 TN 101374 reflectingsurface no higher than 40" above the suspending appliances from the ceiling. The contractor shall provide MSDS for all composite osite LA 5734 TX 17680 Hardware: Operable from inside without use of key or g cfm/s.f. for fenestration and other door products (as p p ME ARC 2596 UT 5881358-0301 p Y finished floor. Mirrors that are intended to be used by determined by NFRC 400 wood adhesives, highlighting the VOC content, and MD 11016 VT 2572 special knowledge or effort and operable by lever type both ambulatory people and wheelchair users must be ■ No place in common Corridors or Hallways complete the `WDC Submittal Form' for each product MA 10635 VA 0401 011223 panic bars, push-pull activating bars not MI 44326 2379 WA 10344 hardware, p p 9 ( at least 74" high at their top most edge, such as might in which visual alarm signaling appliances used. A Go of the form can be found on the LEED MN 44326 wi 9900-005 requiring mounted 30" - 44" A.F.F. are required, shall be more than 50'-0" from Plumbing: copy Mo A-2005029740 WV 3727 q g be provided in a single-occupancy toilet room or any q r Prototype Green Specifications. MS 3860 WY C-1967 Maximum effort to operate doors shall not exceed 5 toilet room having one mirror. the signal. Plumbing systems will be commissioned per the Professional Seal: pounds for exterior doors and interior doors such pull * Grab Bars: * �� requirements of the Commissioning specifications on Contract Closeout: p p Signage:e: , or push efforts being applied, at right angles to hinged the LEED Prototype Green Specifications. Cleaning Materials: Only Green Seal cleaning doors and at the center plane of sliding or folding The nominal diameter or width of the gripping surface When new signs and identification devices are materials shall be used in the final cleanup. Provide doors. Compensating devices or automatic door Heating and Air Conditioning: P operators rn y be gutilized to meet the above or a handrail or grab bar shall be 1 1/4 to 1 1/2 or the provided the new sign and / or identification devices vendor confirmation that the materials used comply SKIN shape shall provide an equivalent gripping surface. If shall comply with the Building Code. with green seal GS37 requirements. Recycle 99 If the HVAC system is used during construction standards. When fire doors are required, the Y g r s maximum effort to operate the door may be increased handrails or grab bars are mounted adjacent to a wall, MERVB filters shall be used during construction, salvage, and return construction and demolition waste GF99 NJ p Y the space between the wall and the grab bar shall be Letters and numbers on signs shall have a width-to- from the project in accordance with the requirements ' not to exceed 15 pounds. rr height ratio between 3:5 and 1:1 and a stroke width-to- replace filtration media with new MERV13 filters prior 1 112 . g in Construction Waste Management on the LEED to occupancy. Filtration media of MERV13 or higher g height ratio between 1:5 and 1:10. Characters and prototype green specifications. OF O •� Exit door hardware shall be of an approved type and The structural strength of grab bars, fasteners and numbers on signs shall be sized according to the shall be used at each return grill. �y11� tested in accordance with procedures established by mounting devices shall meet the following viewing distance from which they are to be read. The Recycle, salvage, and return construction and 1- HVAC and controls will be commissioned per the Consultant: SFM 33.2 and SFM 33.3. specifications: minimum height is measured using an upper case ''. p demolition waste from the project in accordance with Lower case characters are permitted. For signs requirements of the commissioning specifications on p � p g the LEED Prototype Green Specifications. the requirements in Construction IAQ Management on Provide minimum 10" high smooth surface at door Bending stress in a grab bar induced by the suspended or projected above the floor, the minimum tYp p bottoms, either attached anal or bottom rail except the LEED Prototype Green Specifications. p p maximum bending moment from the character height shall be 3". automatic or sliding doors. Electrical and Lighting: application of 250 Ibf shall be less than the Refer to the LEED Prototype Green Specifications for allowable stress for the material of the grab Characters and symbols shall contrast with their the closeout submittals for LEED T14. The minimum space between two hinged or pivoted bar. background. Either light characters on a dark Lighting systems will be commissioned per the doors in a series shall be 48" plus the width of any background or dark characters on a light background. requirements of the Commissioning specifications on door swinging into the space. Doors in a series shall N Shear stress induced in a fastener or the LEED Prototype Green Specifications. 11 swing either in the same direction or away from the mounting device from the application of 250 Where raised characters or symbols are used, they N space between the doors. Ibf shall be less than the allowable lateral shall conform to the following: Insulation: N load of either the fastener or mounting Job Name and Number. 2015-0131 Handles, pulls, latches, locks and other operating device or the supporting structure, whichever A. Letters and numbers shall be raised 1/32' Insulation shall include a minimum of 20%ibl ipost- devces on accessible doors shall have a shape that is �. is the smaller allowable load. and shall be sans serif uppercase characters industrial recycled content. Proposed easy to grasp with one hand and does not require tight and accompanied with Grade 2 Braille. Uf grasping, pinching, or twisting of the wrist to operate. Tensile force induced in a fastener by a B. Raised characters or symbols shall be at The contractor shall complete the `Materials Submittal VERIZ01V Z Hardware required for accessible door passage shall direct tension force of 250 Ibf plus the least 518" high; Form' for all insulation materials used on the project. A STORE be mounted no higher than 48" above the finished maximum moment from the application of C. Pictorial symbol signs (pictograms) shall be copy of the form can be found on the LEED Prototype floor. 250 Ibf shall be less than the allowable accompanied by the equivalent verbal Green Specification. withdrawal load between the fastener and description placed directly below the (LEED) A The maximum force for pushing or pulling open a door the support structure. pictogram. The border dimensions of the The contractor shall provide manufacturer's shall be as follows: pictogram shall be a minimum of 6" in height. information for each insulation product highlighting the ■ Grab bars shall not rotate within theirfittings. post-consumer and/or post-industrial recycled content. M Exterior hinged doors: reserved Contracted Grade 2 Braille shall be wherever Braille ■ Interior hinged doors: 5 foot pounds symbols are specifically required in other portions of ❑ all. Job Address: in Sliding or folding doors: 5 foot pounds A handrail or grab bar and any wall or other surface Y p Y q P r w g g p adjacent to it shall be free of any sharp or abrasive these regulations. Dots shall be 1110" on centers in Washington Square Mall Nelements. Edges shall have a minimum radius of 1/8" each cell with 2110" space between cells. Dots shall Drywall shall include a minimum of 5% post-consumer 9585 S.W. Washington * Drinking Fountains and Water Coolers: be raised a minimum of 1/40" above the background. and/or post-industrial recycled content, and shall be Square Road Z * Controls and Operating Mechanisms: manufactured within 500 miles of the project site. Portland, OR 97223 Spout outlets shall be no higher than 36" measured All building entrances that are accessible to and Space R05-R07 from the finished floor. A clear floor space that allows a forward or parallel usable by persons with disabilities, and at every major The contractor shall complete the `Materials Submittal Z approach by a person using a wheelchair shall be Junction slang or leading to an accessible route of Form' for all drywall used on the project. A copy of the Unit controls shall be front mounted or side mounted travel shall be identified with a sign displaying the form can be found on the LEED Prototype Green Drawing Tide: provided at controls, dispensers, receptacles and near the front edge. other operable equipment. The clear float space shall International Symbol of Accessibility and with Specifications. be 30"x48". directional signs, as required, to be visible to persons General Notes and Z Wall and post mounted cantilevered units shall have a along approaching pedestrian ways as per code. The contractor shall provide manufacturer's Specifications clear knee space between the bottom of the apron and All controls and operating mechanisms shall be information for each drywall product highlighting the N the floor or ground at least 27" high, 30" wide, and 17" operable with one hand and shall not require tight When permanent identification is provided for rooms post-consumer and/or post-industrial recycled content to 19" deep (refer to diagram). and spaces, raised letters shall be provided and shall t. The force be accompanied b Braille in conformance with code. Q required to activate controls shall be no more than 5 p Y Finishes & Painting. Drawn By. North *Water Closets and Toilet Stalls: Ibf. Signs shall be installed on the wall adjacent to the JL Arrow: N Controls and operating mechanisms shall be placed latch side of the door. Where there is no wall space to All paints and finishes shall not exceed the VOC Checked By. o The height of water closets shall be 17" to 19" within forward and side reach positions. the latch side of the door, including at double leaf content listed under Construction IAQ Management on KG 0 doors, signs shall be laced on the nearest adjacent Date Issued For 6 measured to the top of the toilet seat. Seats shall not g p J the LEED Prototype Green Specifications. Client: 12/24/15 be sprung to return to a lifted position. * Alarms: wall. Mounting height shall be 60" above the finished Landlord: 12/24/15 floor to the centerline of the sign. Mounting location Contractor shall provide Materials Safety Data Sheets Permit: 12/24/15 J Flush controls shall be hand operated or automatic. shall be determined so that a person may approach (MSDS) for all adhesives, sealants, primers and paints Bid: P At a minimum visual signal appliances shall be „ Controls for flush valves shall be mounted on the wide within 3 of signage without encountering protruding highlightingVOC content and complete the VOC Construction: W provided in buildings and facilities in each of the objects or standing within the swing of a door. p J g g Submittal Form for each product used. A c4 of the RedslonlDat side of toilet areas no more than 44 above the floor. following areas: Restrooms and any other general p PY No. Date Description usage areas (e.g., Meeting Rooms), Hallways, form can be found in the LEED Prototype Green Toilet paper dispensers that control delivery, or that do LEED: Specifications. Lobbies and any other area for common use. not permit continuous flow, shall not be used. Audible alarms, if provided, shall produce a sound that This project is pursuing US Green Building Council Suspended Ceilings Standard toilet stalls with a minimum depth of 56" exceeds the prevailing equivalent sound level in the LEEDTM Certification. The contractor shall meet the 3 shall have wall-mounted water closets. If the depth of room or space by at least 15 decibels or exceeds any LEED requirements listed under Sustainable Design The contractor shall complete the `Materials Submittal a standard toilet stall is increased at least 3" then a maximum sound level with duration of 60 seconds by and Construction procedures on the LEED Prototype Form' for all suspended ceiling and framing systems 3 floor-mounted water closet may be used (refer to 5 decibels, whichever is louder. Sound levels for alarm Green Specifications. on the project. A copy of the form can be found on the oQ plans/diagrams). signals shall not exceed 120 decibels. LEED Prototype Green Specifications. Z Demolition and Alteration Notes: W Z In standard stalls, the front partition and at least one Visual alarm signals shall be integrated into the The contractor shall provide cut sheets or other side partition shall provide a toe clearance of at least building or facility alarm system. If single station To meet project's LEED goals, the Contractor shall documentation for each suspended ceiling product, W 9" above the finished floor. If the depth of the stall is audible alarms are provided, then single station visual develop and implement a Construction Waste highlighting recycled content information. 3 greater than 60", then the toe clearance is not alarms shall be provided. Visual alarm signals shall Management (CWM) Plan, and divert a minimum of Drawing Number: X required. have the following minimum photometric and location 75% of the total construction and demolition waste Flooring: Z¢ from landfills, See LEED Prototype Green features: YP NM Specifications for additional LEED CWM details. All carpet products must meet the requirements of The �o > I Alm3 !s 5fu 3OF31 MIN MIN MIN 00< 00< GRUSKIN +� DISPLAY/WORK e ARCHITECTURE + PC. 6„ 6' 6" / SURFACE COUNTER MIN 294 Morris Avenue Springfield,NJ 07081 EQ, EQ, EQ. EQ, z z / z Tel: 973.376.4411 Fax: 973.376.8989 N ry . www.Grusl<inGroup.com NJ REG 0100.9869.14 This document and the Ideas and designs Incorporated LIN herein, as an Instrument of professional service,Is the TO property of GRUSHIN ARCHITECTURE+DESIGN,P.C.,and z EXIT / T' Is not to be used In whole or In part for any other project '} without the written authorization of GRUSHIN EXIT MEN WOMEN - RESTROOM ARCHITECTURE+DESIGN,P.C. All Rights Reserved 1/2" 1 m m MIN• (BRAILLE) w MIN. (BRAILLE) w m (BRAILLE) _ m (BRAILLE) _ m (BRAILLE) 2015 Gruskin Architecture+Design,P.C. 1 1 % c Kenneth A. Gruskin AIA 10 d' n u z AL 5421 MT 2537 "U �1 AK 13167 NC 9961 f o v m ~ AR 3811 ND 1666 AGGE551BILI7Y SYMBOL TACTILE 51GN TACTILE SIGN TACTILE SIGN TACTILE SIGN TACTILE SIGN _ AZ 39209 NE A-3547 CA C-29898 NH 2796 CO ARC-400347 NJ AI 09999 3 1 SCALE: "= '-0" SCALE: 3"=1'-0" v SCALE: 3"=1'-0" o CT 9613 NM 004168 DC ARC100723 NV 5521 DE 0006261 NY 025528-1 NY FL AR91629 OK a4895 NOTE:MOUNTED 30"MIN• GA RA011075 OH 13761 CLLEEAR OF DOOR�5WING. THE TO 13E LOCATED OFTHE LOWE5T BRAILLE POOP,N LATCH 51DE OF EMPLOYEE LOCKER CLEAR A AR 11489 OR 4899 RA- IA 05713 PA RA-01 5432-B CELLS SHALL BE 48"MIN.A.F.F.AND THE BASELINE OF THE HIGHEST SIDE REACH DIAGRAM 8 DISPLAY WORK SURFACE COUNTERS ID AR-984459 PR 19965 LINE OF RAISED CHARACTERS SHALL BE 60'MAX.A.F.F. IL 001-019152 RI 2666 IN AR10400066 SC 6834 KS 4674 SD 11532 KY 5967 TN 101374 LA 5734 TX 17680 ME ARC 2596 UT 5881358-0301 MD 11016 Vr 2572 MA 10635 VA 0401 011223 'CFI'OUTLET, MI 1301052379 WA 10344 MN 44326 WI 9900-005 SEE GTR G 17-25 MO A-2005029740 WV 3727 48'X 30"CLEAR 50AP DISPENSER VERTICAL GRAB 54 MIN MS 3860 WY C-1967 CLEAR PAPER TOWEL FLOOR SPACE BY 36"MIN. NOTE: DISPENSER SECTION 3053 GRAB BAR 3b'X 24'MIRROR BAR(�) Professional Seal: SINK 42"MIN• 12" DASHED LINES INDICATES ACCESSIBLE VERTICAL GRAB PAPER TOWEL FIXED SIDE WALL 'IMAX _ — — — — BAR(�) DISPENSER ON GRAB BAR(TAL) 39"-41" OF OPTIOEN51O AL CLEARANCE HAT AND COAT—L" SIGN � SINK-� ^I REAR WALL 12 24 51DE WALL HOOK(B-682) / MIN. MIN. LAVATORY ENCLOSURE EQ. EQ. GRAB BAR(TYP) Al F- _ TOILET SINGLE ROBE �, I�\ � l(,� I FLOOR ® WATER PAPER SINK-I HOOK(8-611). 8899 SPACE CLOSET WC-1 = a ® N z z _ DISPENSER u, NJ --CLEARANCE AROUND :r m z �? m PAD PIPES TO PROTECT r z _ _ \ !NATER CLOSET — — — — - y `L - d' - _ - �x / SPRII`1�FIELD, \ / m m `r m m = - 7 AGAINST CONTACT S m 48, _ - m m — - PER GENERAL NOTES T / `�Y O b>l� a 1. BAR()GRAB MIN. SEAT GOER PROVIDE ENCLOSURE OR WATER 6"MAX. 8" MIN.KNEE INSIDE OUTSIDE IV 16"-18° 24"-42"015FENoER INSULATE DRAIN E HOT CLOSET MIN.LEG CLEARANCE 11" CLEARANCE 56" WATER LINES BELOW LAV. WG-1 MIN. Consultant CLEAR FLOOR 5PAGE AT WATER CLOSET PLAN AT LAVATORY FRONT ELEVATION AT WATER CL05ET AND LAVATORY SIDE ELEVATION AT WATER CLOSET 51DE ELEVATION AT LAVATORY RESTROOM DOOR ELEVATION AGGE551BILITY DETAILS NOTES: NOTES: SIGN MOUNTING NOTE: • ALL DIMENSIONS ARE FIN15H DIMENSIONS. I FLUSH CONTROLS SHALL BE LOCATED ON THE OPEN BRAILLE SHALL BE 48'MIN.AND 60"MAX.ABOVE THE • ALL PLUMBING FIXTURES AND ACGE550RIE5 SHALL 5112E OF THE WATER CLOSET. FLOOR,MEASURED TO THE BASELINE OF BRAILLE. N.T.S. BE ACCESSIBLE.VERIFY ALL ACCE551BLE DESIGNSSEE SHEET A2 FOR ADDITIONAL INFORMATION. • ' RAISED CHARACTERS SHALL BE 48'MIN.AND b0"MAX. FOR CONFORMANCE WITH FEDERAL,STATE AND • DISPENSER MOUNTING HEIGHT AND PROJECT SHALL ABOVE THE FLOOR,MEASURED TO THE BASELINE OF RA15ED LOCAL GODE5. BE REFERRED TO TABLE 603.6. OHARA(TER5 IF THE 516N DOES NOT CONTAIN BRAILLE. v 0 u� v N NOTE: Job Name and Number. 2015-0131 1 VERIZON WIRELE55 BILL PAYMENT TELOO Proposed � KI05K HAS STANDARD ATM PIN 41 TOTAL OCG. = I ENTRY PAD WITH BRAILLE AND � AUDIO PORT FOR ACJA COMPLIANCE. I — V E R I ZO N w F KI05KPAYMENT SCREEN TOUGH SCREEN 5 — — — — —•— — — i w STANDARD ATM W � TORE PIN ENTRY PA12 RE5TROOM _••—-- C 1 WITH BRIE � TOTAL OCG. =1 0 (LEED) CARD READER . \ LLJ A — W 8° ° I INVENTORY ° _ i �—'' TOTAL OCG. = I _ L RE5TROOM MANAGE ro F ®° y, I TOTAL OCG. =1 ® I o m = v i ��� a+ TOTAL OCG. =1 � Job Address - N Washington Square Mall `•��1. LEGEND 9585 S.W. Washington Cd m _ v\ � o F— o CLEAR FLOOR " M1 BPI EP ®''•fir ® Square Road •`+ ELEG.ROOM -`'''—"—"—" E6RE55 ROUTE WITH X NUMBER Portland, OR 97223 � � 9 I o Z SPACE � TOTAL OCG. =I _ J �..—.. . w OPEN OFFICE O � I - TOTAL OCG. = 5 -- -- ■■ •■ OF EXITING OCCUPANTS FROM Space R05•R07 4'-0' EAKAREA 5PAGE WITH TRAVEL DIRECTION --- --- --- --D17;I --- --- --- -- PLAN VIEW FRONT VIER BPK 51DE REACH LIMITS TOTAL OCG. = 2 �� DrawingTlde: i ROOM AREA (5F) OGGUPANGY BILL PAYMENT MACHINE BPK EQUIPMENT FOR PERSONS WITH V15ION IMPAIRMENTS: I `� . . Z IN5TRUGTION5 AND ALL INFORMATION FOR USE 5HALL BE I SALES AREAS @ 3o GR055 5F/BGG. Accessibility Details, 5112E REACH DIAGRAM MADE ACCESSIBLE TO AND INDEPENDENTLY USABLE BY I I � � I RETAIL SALES 2,286 17 Matrix and Egress N 1 O SGALE.1/2" 1'-0" PERSONS WITH VISION IMPAIRMENTS. i I a I® g OFFIGE5 @ 100 6RO55 SF/OCG. Diagram I OPEN OFFICE 440 5 LD I I I MANAGER 84 1 El 11Drawn By. North Q BREAK AREA 151 2 Arrow. W ` --- RETAIL SALES - RESTROOM5 155 2 A N BOTTLELE55 WATER --- TOTAL OCC. = 71 J I Checked By. COOLER I - - -------- I KG A CUP ROCKER I \ ____= 0 •• •• I NyORAGE 1�300 GR055 5F/OCG. Date Issued 12/24/15 TELCO 69 1 Landlord: 12/24/15 L� I I ELECTRICAL ROOM 44 1 COOLER WATER 4'-0" I I / V ✓ v \ I TOTAL 3,389(SF) 90 BidPer: 12/24/15 MIN.GLR. I ' , Q .00/ Construction: f 1'-2" _ 1'-4"/ I `� ` I Q / I SEE REFLECTED CEILING PLAN ON SHEET A5 FOR EXIT Revision Issue: w 2'-6" I I �> <� I SIGNS ALONG PROP05ED EORF-55 ROUTE 5HOWN. No. Dace Descrlpdon IN.GLR. I NOTE:SEE BUILDING DATA'ON DOVER SHEET FOR MORE INFORMATION D z L J Ig S t=ip 3 FAUCETS E307LELE55 WATER B0TTLELE55 WATER 4q COOLER PLAN COOLER ELEVATION 13 EGRESS DIAGRAM cu z 11 SCALE:1/4"-1'-0" 1 SCALE: 1/4"-1'-0" SCALE: 0 L w 0 L7 �3 �A w 3 Q Drawing Number, Q X" X(U /Q Z 0 CD W r In A2 !o c 4 OF 31 EX15TIM EGRE55 DOOR TO REMAIN REMOVE IX15TI116 TRANSFORMER EXISTING PLUMBING PIPES TO REMAIN REMOVE EXISTING ELECTRICAL DISCONNECT \ — II r -_ — — DEMOLITION KAY: RUSKIN \ II F = = = \ II ARCHITECT,JRL - DESIGN.PC. L — -1 \ EXI5TIN6 TO REMAIN \ 294 Morris Avenue Springfield,NJ 07081 FP _U \ =Z== EX15TING SLAB TO BE REMOVED Tel: 9 ruskin.441 I Fax:973 0100.9 989 www.GruskinGroup.com NJ 0.EG 0100.9869-N IIM== EXISTING TO BE REMOVED This document and the Ideas and designs Incorporated II gn P FP II herein,as an Instrument of professional service,Is the L EXI5TING FIXTURE TO BE REMOVED property of GRUSKIN ARCHITECTURE+DESIGN,P.C.,and Is not to be used in whole or In part for any other project ( = ARCHITECTURE+DESIGN,P.C. All Rights Reserved REMOVE EXI5TING IDEM®LITI®N NOTE: ELECTRICAL PANEL,SEE REMOVE PORTION OF WALL TO I. ELECTRIC, IN MI-5 TO BE REMOVED SHALL BE DISCONNECTED AT ©2015 Gruskin Architecture+Design,P.C. DEMOLITION NOTES(TYPJ PROVIDE OPENING FOR NEW DOOR, MAIN PANEL BOARD OR JUNCTION BOX. EP \ I I REMOVE EXISTING WATER SEE ARCHITECTURAL PLAN Kenneth A. Gruskin AIA \ I CLOSET,SEE PLUMBING 2. REMOVE ANY EXI5TIN6 ELECTRIC AND LIGHTING NOT BEIN6 USED, AL 5421 MT 2537 REMOVE EXI5TING \ I I DRAWINGS 4 DEMOLISH AND REMOVE EXISTING UU55 OTHERWISE NOTED(TYP). AK 13167 NC 9961 ELECTRICAL DISCONNECT -u RE5TROOM5. REMOVE ALL PLUMBING AR 3811 ND 1666 FIXTURES. REMOVE AND GAP ALL 3. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO GUT AND AZ 39209 NE A-3547 CA C-29898 NH 2796 FLOOR AND WA5TE DRAINS(TYP.) PATCH SLAB AS REQUIRED FOR NEW ELECTRICAL(ONPUIT5 AND CO ARC-400347 NJ Al 09999 _ _ = F = = FLOOR 13045).VERIFY ALL OR ANY 5TRUGTURAL MEMBERS WHICH CT 9613 NM 004168 APPROXIMATE LOCATION \ - MAY INTERFERE WITH TRENCH. ELECTRICAL CONTRACTOR SHALL DC ARC100723 NV 5521 OF LEASE LINE I II \ IDENTIFY PRECDE 0006261 NY 025528-1 NY ISE LOCATIONS AND DEPTH IN FIELD AS REQUIRED. FL AR91629 OK a4895 GA RA011075 OH 13761 REMOVE DOOR UNIT 4. REMOVE ALL EXISTING MECHANICAL EQUIPMENT,DUCTWORK, HI AR 11489 OR 4899 PLUMBING FIXTURES,PIPING SYSTEMS,ETC.,NOT BEING RE-USED. DO IA 05713 PA RA-015432-B rT \ AND FRAME,TVP. i n n- ID AR-984459 PR 19965 I / REMOVE EXISTING GRAB / I I I I \ _ REMOVE EXI5TIN7 PARTITION AT THI5 POINT, NOT.BUST ABANDON.(COORDINATE WITH MECHANICAL PLANS) IL 001-019152 RI 2666 \ / BAR5(TYPJ I r o / I II I I \ STRIP OFF EXI5TIN6 GYPSUM WALL BOARD TO IN AR 10400066 SC 6834 / II TRANS. THE NEAREST CENTER OF REMAINING STUD AT 5. REMOVE EXI5TING FLOOR FINISHE5 DOWN TO EXI5TING SLAB UNLE55 KS 4674 SD 11532 — KY 5967 TN 101374 L EACH 5IDE OF EXI5TIN6 PARTITION OTHER11I5E NOTED(TYPJ.GLEAN,PATCH AND LEVEL EXI5TIN6 LA 5734 TX 17680 CONCRETE SLAB A5 REQUIRED FOR NEW FINISHES. ME ARC 2596 UT 5881358-0301 ® __ 1 REMOVE EXI5TIN6 TRANSFORMER MD 11016 VT 2572 T b. REMOVE ANY EXI5TING 5U5PENDED GEILING GRID5,TILE5 AND HVAC MA 10635 VA 0401 011223 T REMOVE EXI5TIN6 REMOVE EXISTING PARTITION,TVP. — — — — — — — — — — — — MI 1301052379 WA 10344 THERMOSTAT(TYPJ _ REMOVE EX15TIW SINKS, REMOVE EXISTING GRILLES,UNLESS OTHERWISE NOTED(TYPJ- u, ELECTRICAL PANEL,SEE MN 44326 WI 9900-005 SEE PLUMBING DRAWINGS MO A-2005029740 WV 3727 DEMOLITION NOTES(TYP) 1. REMOVE ANY EXI5TING WALL COVERING FINISH,UNLE-55 OTHER 15E MS 3860 WY C-1967 EXISTING TENANT DEMISING NOTED(TYP). Professional Seal: PARTITION,VERIFY WALL WIDTH A5 NEW TENANT DEM151NG PARTITION 8. REMOVE ANY EXI5TIN6 INTERIOR SOFFITS,UNLE55 OTHERA15E NOTED RUNS TO UNDERSIDE OF READ,TYP. PROVIDED BY LANDLORD. CONTRACTOR DECK ABOVE. ( ) TO VERIFY WALL RUNS TO UNOER51DE OF / DECK ABOVE. q. REMOVE ALL DEBRIS FROM ALL ROOMS(TYPJ 10. CONTRACTOR SHALL NOTIFY ARCHITECT IMMEDIATELY IF EXI5TING GRUSKIN COLUMN LOCATIONS AND SIZES ARE DIFFERENT FROM WHAT OCCURS IN THESE DRAWINGS,AND OF ANY UNDOCUMENTED 899 NJ T f 5TRUGTURAL COLUMNS OR CONDITIONS,PIPES,ETC.,WHICH ARE P GFI LOCATED IN THE TENANT SPACE BUT DO NOT APPEAR IN THESE COEI.D, EX15TING COLUMN DRAWINGS,50 PRANIN65 GAN BE REVI5ED AS MAY BE REQUIRED �S TO REMAIN(TYPJ TO ACCOMMODATE THE A5-BUILT CONDITIONS. OF Q / II. PLUMBING CONTRACTOR SHALL BE RE5PON51BLE TO 5AW GUT AND Consultant: REMOVE EXISTING CONCRETE SLAB FOR TRENCHING AS REQUIRED / FOR NEW PLUMBING FIXTURES;COORDINATE WITH PLUMBING CONTRACTORS TO IDENTIFY PRE015E LOCATIONS AND DEPTH IN REMOVE EXISTING GEILING TILES,GRID,LIGHTS, FIELD AS REQUIRED. VERIFY ALL OR ANY STRUCTURAL MEMBERS / DIFFUSERS AND OTHER DEVICES;COORDINATE Q d WITH MECHANICAL CONTRACTORS AND WHICH MAY INTERFERE WITH TRENCH. EXCAVATE ADDITIONAL ELECTRICAL CONTRACTORS. TRENCH AS REQUIRED TO CONNECT NEW 501L LINES TO EXISTING MAIN,V.I.F.,VERIFY WITH LANDLORD AND EX15TIN6 BUILDING SYSTEM FOR PRECISE LOCATION AND DIRECTION. SEE PLUMBING PLANS. In FMANAHMENT ®N5TRUGT ON WA5TE N®TE5: N GUT/TRENCH EXI5TIN6 SLAB A5 REQUIRED FOR / I. CONTRACTOR SHALL RECYCLE OR SALVAGE ALL P0551BLE lob Name and Number. 2015-0131 NEW CONDUITS. SEE ELECTRICAL DRAWIN65 CONSTRUCTION AND DEMOLITION MATERIAL PER THE REQUIREMENTS FOR LOCATION. VERIFY WITH VERIZON L15TED UNDER CONSTRUCTION WASTE MANAGEMENT ON THE LEED Proposed WIRELE55 PROJECT MANAGER $ LANDLORDS PROTOTYPE GREEN SPECIFICATIONS. TENANT COORDINATOR PRIOR TO ANY GUTTING. VERIZON 2. CONTRACTOR SHALL PROVIDE A COPY OF ALL TIPPING RECEIPTS / INDICATING THE REGYCLING OR 5ALVAGE OF MATERIALS. w a ZI / 3. CONTRACTOR SHALL PROVIDE CONTAINERS AND BINS ON-51TE TO STORE U _ / FACILITATE RECYCLING,A5 SPECIFIED UNDER CONSTRUCTION K45TE LEED) o / MANAGEMENT ON THE LEED PROTOTYPE GREEN 5PEGIFICATION5. 4. CONSTRUCTION MANAGER TO VERIFY IF EXI5TIN6 FURNITURE TO REMAIN 15 GREEN GUARD CERTIFIED. INFORM PROJECT MANAGER AND ARCHITECT ON COMPLIANCE. i 5. GON5TRUCTION MANAGER TO VERIFY IF EXI5TING EQUIPMENT TO Joh Address REMAIN 15 ENERGY-STAR RATED. INFORM PROJECT MANAGER AND ARCHITECT ON COMPLIANCE. Washington Square Mall `u 9585 S.W. Washington b. GON5ULT WITH VERIZON NRELE55 PROJECT MANAGER FOR ALL Square Road EQUIPMENT,FIXTURES,FURNITURE TO BE REMOVED. STORE,DISPOSE, w EXI5TIN6 COLUMN TO REMAIN, CAREFULLY - — — — — — — — - — — — — — — — — — — — oR RE-USE ITEMS A5 DIRECTED BY VERIZON WIRELESS. Portland, OR 97223 REMOVE 5URROUNDIN6 WALL5. VERIFY Space R05-R07 LOCATION PRIOR TO DEMOLITION. A REPAIR AND PATCH THE COLUMN A5 REQUIRED NOTE: CONSULT WITH VERIZON HIRELE55 a PROJECT MANAGER FOR ALL EQUIPMENT, DrawingTlde: ry i ry FIXTURES,FURNITURE TO BE REMOVED. STORE, I I /\ I II I Ar VERT SE,OR REQ ITEMS AS DIRECTED BY ull / \ ►1111 /\ I Idll \ IIII ILII , �' \� , II►II // \\ ii IG�I , �� \� ` IT Demolition Plan -�6 = _ _ - = = (1J L3 Z 3 Drawn By. North II Arrow. REMOVE EXI5TIN6 TILE--JChecked By JL N MALL NEUTRAL PIER TO REMOVE EXI5TIN6 STOREFRONT AS REQUIRED FOR NEW PROVIDE SAFETY BARRIER WITH DOOR ACCESS DURING KG o REMAIN FRAMING AND GLAZING STOREFRONT,SEE DEMOLITION AS REQUIRED BY 'OSHA'STANDARDS TO Date Issued For A ARCHITECTURAL PLAN PROTECT MALL INTERIOR FROM DEMOLITION AND NEW Client: 12/24/15 ¢ WORK. BARRICADE TO BE PROVIDED BY MALL AT TENANT Landlord: 12/24/15 EXPENSE. TENANT TO PROVIDE BARRICADE 6RAPHIC5. Permit: 12/24/15 DEMOLITION PLAN SUBMIT GRAPHIC5 PROP05ED FOR LANDLORD REVIEW Bid: 1 w SGALI=. 174- 1-0 Construction: Revision Issue: QNo. Date Description C 0 Z 2504psi MIN.CONCRETE INFILL 0 #4 REBAR DOWEL5® 24"O.G. 3" TRENCH INFILL 3" MAX. EMBED EMBED 3"MIN.EMBEDMENT 3 '�► EXISTING SLAB (U GRAVEL I"MIN. Z 0 LD a \\%\\%/\\j\\jj\\jam\\i\\ice\ \\ \ \��\\/�\\//�\//�\//�\//�\ \��\\��\�\\�\ w o CONDUIT,REFER TO ELECTRICAL PLAN(TYP) Drawing Number: 3 Q TRENCH INFILL DTAtIL x - X z o Xo wt >in o `� 5 OF 31 OWNER/TENANT: 5/8" 3/4" X 3/4" METAL 5/8" G.W$ OVER REVEAL PTD. BLACK METAL FRAMING 4 I/2" ol 00 GODIVA Chorolatier GODIVA CHOCOLATIER, INC. 333 WEST 34TH STREET 1/4" TEMP. GLASS NEW YORK, NY 10001 BRAKE METAL OVER + + (VF-I) PROJECT PLANNER: 3/4" F.R.T. PLYWOOD GLAZING SYSTEM INTERMEDIATE is 8" 16GAUGE BOX BEAM _ N F.R.T. BLOCKING GLAZING CHART AS REQUIRED 1/2" TEMP. GLASS UNSUPPORTED SPAN MIN. RECOMMENDED 1/2" X 1/2" METAL WJCA INC. FROM TOP TO BOTTOM THICKNESS OF FULLY OF GLASS TEMPERED GLASS REVEAL FTC). WHITE 763 SUSQUEHANNA AVE. UP TO 5'-0" 1/4" �, FRANKLIN LAKES, 9NJ 0 507417 60 OVER '-O" UP TO 8'-0" 3/8" $5/8" G.WOVER METAL FRAMING FAX: 201-848-9881 OVER 8'-0" UP TO 10'-0" 1/2" TEL: 201-848-90 OVER 10'-0" UP TO 12'-0" 5/8" OVER 12'-0" UP TO 14'-0" 3/4" GLAZING SYSTEM ARCHITECT: HEAD OVER 14'-0" UP TO 16'-0" T/8" OVER I6'-0" UP TO 18'-0" I" I/4" TEMP. GLASS OVER 18'-O" NOT RECOMMENDED DAVID A. UDKOW 11881 NORTH 113TH WAY GLAZING CHART 6 NOT USED 5 SECTION SCALE: 3" = T-0" J(D SECTION SCALE: 3" = V-011 SCOTTSDALE, AZ 85259 C X O U LIC. #: 2182 O EXP. DATE: 6/30/16 le GODIVA + MALL BULKHEAD MALL BULKHEAD MALL BULKHEAD Chocolatier + STORE NO: TAL 3/4" BLACK REVEAL 3/4" X 3/4" METAL REVEAL PTDEBLACK 524 •> REVEAL PTD. SLACK `V 5/8" G.W$ OVER 5/8" GAL$ OVER PROJECT LOCATION: METAL FRAMING METAL FRAMING � 0" 14'-0" � 0" ---� T.O. REVEAL T.O. REVEAL BRAKE METAL OVER TO. REVEAL WASHINGTON MALL + + 3/4" F.R.T. PLYWOOD + ++ BRAKE METAL OVER SPACE B04 + + ++ 3/4" F.R.T. PLYWOOD 9585 SW WASHINGTON Lo SQUARE ROAD (v PORTLAND, OR 90703 + + co 8" BOX BEAM 8" BOX BEAM i F.R.T. BLOCKING AS F.RT. BLOCKING AS ISSUE DATE: Q ++ ++ ++ ++ REQUIRED ++ ++ ++ ++i REQUIRED SII'-6" r,11'-6" ++ ++ ++ ++ �11'_6n ++ ++ ++ ++ 5 NO. DATE DESCRIPTION S.O. GAL$. CLG. SO. GAL$. CLC. 3 5/8" X 20GA. DIAGONAL B.O. GW$. GLC. 12-11-15 issueDFORRID, W BRACING O 48" O.G. TO A201 PERMIT AND LANDLORD REVIEW SUSP. G.W$. CEILING SUSP. G.W.B. CEILING STRUCTURE ABOVE. SUSP. GAL$. CEILING 3 5/8" X 20GA. DIAGONAL Q BRAKE METAL OVER 1/2" F.RT STOREFRONT SIGN PANEL BRACING a 48" O.G. TO Q PLYWOOD ON METAL FRAMING REFER TO SIGN MFR SHOP STRUCTURE ABOVE. EXISTING COLUMN EXISTING COLUMN DRAWINGS EXISTING COLUMN vJ BEYOND BEYOND BEYOND - 1/4" TEMP. GLAZING (VF-1) 4 B.O. SOFFIT 9'-0" hg 0 5/8" G.W$ OVER METAL B.O. MULLION B.O. MULLION A201 r , FRAMING REX 1/2" METAL r�.//� REVEAL PTD. WHITE \lll vJ EQ. I'-6 1/2 1/2" X 1/2" METAL TENANT SPACE MALL CONCOURSE TENANT SPACE MALL CONCOURSE REVEAL PTD. WHITE 4" V-1" TENANT SPACE 8" 2'-6" ol MALL CONCOURSE Q 4 1/2" 3'-9 1/2" RECESSED LIGHT FIXTURE ol REFER TO SHEET A102 17- V-9 1/2" RECESSED LIGHT FIXTURE REFER TO SHEET AI02 ` (? f 1/2 CLEAR TEMP. �. I/2" CLEAR TEMP. GLAZING w�` le T i GLAZING 1-w DAVID A. UDKOW t,-. T GLAZING SYSTEM =421$2 _ FRAMING BEYOND o GLAZING SYSTEM I� SCOTTSDALE, A �,� FRAMING BEYOND ��j LL ©1 6 0 LEASE LINELEASE LINE Z STOREFRONT Co GLASS DOOR DRAWING TITLE: co STOREFRONT r DETAILS 0 Y Q FIN FLOOR FIN FLOOR FIN FLOOR PROJECT NO: FL TENANT MALL TENANT MALL TENANT MALL 154129 Q y FLOORING FLOORING FLOORING > FLOORING /, FLOORING FLOORING DRAWING NO: Q INSTALL MALL FLOORING TO CLOSURE LINE PROVIDE INSTALL MALL FLOORING TO CLOSURE LINE PROVIDE INSTALL MALL FLOORING TO CLOSURE LINE PROVIDE SMOOTH CONTINUOUS TRANSITION BETWEEN DIFFERENT SMOOTH CONTINUOUS TRANSITION BETWEEN DIFFERENT SMOOTH CONTINUOUS TRANSITION BETWEEN DIFFERENT A201 Q FLOOR MATERIALS - FLASH PATCH AS REQUIRED. FLOOR MATERIALS - FLASH PATCH AS REQUIRED. FLOOR MATERIALS - FLASH PATCH AS REQUIRED. 3 SECTION AT SIDE SCALE: 3" = V-a' 2 SECTION AT ENTRY SCALE: 3/4" = V-0" (DSECTION AT GLAZING SCALE: 3/4" = V-0" Q PROVIDE(1)LAYER 314"COX FIRE ARCHITECTURAL KEY: RETARDANT PLYWOOD ON ALL WALL5 EXI5TING WALL5 TO REMAIN PANIC HARDWARE BY WITH EQUIPMENT,FULL HEIGHT OF ROOM. 5ECURITY VENDOR(TYPJ PLYWOOD SHALL BE PRIMED AND NEW WALL5(UP TO b'ABOVE CEILING GRID) -SEE DETAIL WAS LINE OF 5-0 0 WHEELCHAIR TURNING PAINTED. SPACE.SEE ACCESSIBILITY DETAILS PROVIDE A TACTILE EXIT SIGN WITH ON SHEET A2 THE WORD EXIT. SEE SHEET A2 FOR TELCO LAYOUT,SEE ELECTRICAL NEW WALL5 UP TO STRUCTURE ABOVE -SEE DETAIL b/A8G RUSKIN LINE OF CLEAR FLOOR SPACE. SEE ALIGN FINISHES3 5/S° DRAWINGS FOR MORE INFORMATION. ARCHITECTURE + DESIGN.PC. 10 10'-1° ACCESSIBILITY DETAILS ON SHEET A2 (BOTH 5IDE5) FRAM.TO FIN. ARCH I TECTURL N®TSS: 294 Morris Avenue Springfield,NJ 07081 Te1: 973.376.441I fax: 973.376.8989 _ _ I. ALL NEW WALL5 SHALL BE 3-5/8"OR b"(20 GAUGE)METAL www.GruskinGroup.com NJ REG 0100-9869-19 12" STUDS AT Ib"O.G.WITH 5/8"GYP5UM BOARD BOTH 5IDE5 AND MIN. I o FULL INSULATION,UNLE55 OTHER 15E NOTED. This document and the Ideas and designs Incorporated z herein, as an Instrument of professional service,Is the GLR. JL u property of GRUSHIN ARCHITECTURE+DESIGN,P.C.,and TELCO =; 0 2. RATED WALL CONSTRUCTION SHALL BE 3 5/8"METAL STUDS AT is not to be used In whole or in part for any other project FP without the written authorization of GRUSNIN C � � I b'O.G.WITH(U LAYER 5/8'TYPE 'X' GYPSUM BOARD BOTH / MENS \ \ 10� ARCHITECTURE+DESIGN,P.C. N.I.G. � SIDES,FULL HEIGHT TO UNDERSIDE OF STRUCTURE ABOVE AND All Rights Reserved REFROOM���, 0 FULL INSULATION.U.L. DE51GN NO.U41q. NPIP .I.G. I / 108 / ©2015 Gruskin Architecture+Design,P.C. INFILL EXISTING DOOR WITH 3 5/8" 1� / — — — — — 3. ALL NEW WALL5 SHALL EXTEND b"ABOVE SUSPENDED CEILING, Kenneth A. auskin AIA METAL 5TUD5® Ib O.G.WITH FULL BATT \ / 22 m UNLE55 OTHERWISE NOTED. INSULATION AND 6YP5UM BOARD ON • / / r AL 5421 MT 2537 EACH SIDE. MATCH AND ALIGN PROVIDE REQUIRED 51GW `s' 4. ALL DIMEN51ON5 ARE FRAMING DIMENSIONS,UNLESS OTHERWISE AR 381AK 67 ND 1666 NC 9961 FINISHES. IDENTIFICATION FOR DIFFERENT NOTED. AZ 39209 NE A-3547 GENDER,SEE SHEET A2 < PROVIDE(1)LAYER 3/4"COX--\ CA C-29898 NH 2796 ENERGY STAR REFRIGERATOR SUPPLIED (TVP.AT RESTROOMS). �— m FIRE RETARDANT PLYWOOD 5. ALL NEW DOORS SHALL BE 4`OFF WALL(AT HINGE SIDE),UNLESS CO ARC-400347 NJ Al 09999 AND INSTALLED BY GENERAL CONTRACTOR. I • AND AMIGO WIRE SECURITY OTHERWISE NOTED. CT 9613 NM 004168 / \ \ DC ARC100723 NV 5521 MESH,FULL HEIGHT TO DECK / W0 ABOVE.No GYP BD " FDL AR91629 OK a4895261 NY 8-1 NY I< RESTROOM �_ REQUIRED EXCEPT AT RATED b. PROVIDE(2)ROWS MINIMUM 8 HIGH,20 GAUGE HORIZONTAL GA RA011 075 OH 13761 MANAGER o \ 5TRAPPING ON 5TUD5 AT ALL WALL5 WITH CABINETS. HI RA 11489 OR 4899 107 �� I WALLS OR REQUIRED BY IA 05713 PA RA-015432-B 105 oo / / I GODS.PLYWOOD SHALL BE I. ANY DRYWALL FINISH WHICH 15 EXISTING TO REMAIN SHALL BE ID AR-984459 PR 19965 N ? \ \ / / PRIMED AND PAINTED.SEE IL 001-019152 RI 2666 ALIGN FINISHES v �L� DETAIL b/AS � � � PATCHED,PRIMED AND PAINTED TO LEVEL 5 CONDITION AND TO IN AR10400066 SC 6834 REF — — —I — — — _ ` 8'-4" I cn ACCEPT NEW FINISHES. CONTRACTOR SHALL DETERMINE BEST KS 4674 SD 11532 J — — — gg METHODS FOR PATCHING,OR IF DRYWALL WILL NEED TO BE KY 5967 TN 101374 FRAM.TO FIN. I tii LOCATION OF PROPOSED ELEGTRIGAL REMOVED OR REPLACED TO ACHIEVE X5IRED FINISH.EXAMPLE: LA 5734 TX 17680 PANELS,SEE ELECTRICAL PLANS. LL, © RECYCLING CENTER BY a, INVENTORY PATCH DRYWALL WHERE ITEMS ARE REMOVED SUCH A5,BUT NOT ME ARC 2596 UT 5881358-0301 106 MD 11016 Vi 2572 � CABINET CONTRACTOR �. I LIMITED T0,ELEGTRIGAL BOXES,TRIM,MIRRORS,DDOR JAMBS, HALIGN FINISHES MA 10635 VA 0401 011223 LAMINATE COUNTER WITH CABINETS "' I WALLCOVERING,ETC. MI 1301052379 WA 10344 ABOVE AND BELOW. SEE SHEET A9 MN 44326 WI 9900-005 ELEG. ROOM EP EP EP o I 8. IT 15 THE CONTRACTOR'S RESPONSIBILITY TO SMOOTH ALL ROUGH MO A-2005029740 WV 3727 1 4 BREAK AREA I 5URFAGES ON FLOORS OR PATCH,FILL OR FLOAT EXISTING MS 3860 WY C-1967 o WALL MOUNTED SMART BOARD® bb"A.F.F. WALL MOUNTED FIRE I 4 I FLOORS TO A SMOOTH CONDITION CAPABLE OF RECEIVING NEW Professlonal5eal: 103 _ _ _ _ _ _ J FIN15HED FLOOR COVERING.EXAMPLE: AT ALL REMOVED WALL v FILE O.G.AND PROVIDE BLOCKING 8'HIGH 20 GA EXTINGUI5HER PROVIDED BY AREAS,STRIPPED MATERIAL LOCATIONS(I.E.VINYL TILE, O HORIZONTAL.STRAPPING ON STUDS.REFER GENERAL CONTRACTOR.SEE � CERAMIC TILE,CARPET,ETC.),CONDUIT FEEDS AND CHIPPED GRAPHIC STORAGE m F-41 F=I TO DETAIL b/Ab GENERAL NOTES. I CONCRETE,EEG. 7 CABINET OPEN OFFICE q. PATCH AND LEVEL EXI5TIN6 CONCRETE SLAB A5 REQUIRED FOR USKIN 102 POOR3'-10" NEW FINISHES. 4899 PROVIDE METAL 5TRAPPING ON—_,v 10. CONTRACTOR SHALL PROVIDE OPTIONAL PRICING TO LEVEL OR STUDS FOR DEVICE DISPLAY FIXTURE. 15'-7" 5'-b" 5'-b" 15'-4" SMOOTH FLOORS THAT HAVE DEPRESSIONS OR DIP5 GREATER NGFIELD,Nf o THAN I"WITH GYPCRETE OR OTHER SELF-LEVELING COMPOUND. _3� SEE FURNITURE PLAN FOR FIXTURE �'" LAYOUT AND DETAIL 4/Ab FOR BOTTLELE55 WATER COOLER BY VERIZON O 5TRAPPING MOUNTING HEIGHT(TYP.). J I WIRELE55. PIPING BY PLUM5IN6 CONTRACTOR. m 11. PATCH ALL EXI5TIN6 WALL5 A5 REQUIRED DUE TO NEW WORK. OF l PROVIDE RECESSED VALVE BOX BEHIND(VB-1) I z z AT+12'A.F.F.TO CENTERLINE. i ® m So 12. THERMOSTATS,FIRE EXTINGUISHERS,CABINETS,OR ANY OTHER Consultant: FIRE EXTI%UI5HER WITH CABINET, w '�S WALL MOUNTED ARCHITECTURAL ACCESSORY 5HALL BE RECE55ED IN WALL AND PROVIDED BY 5'-T" INSTALLED PER PLAN. DO NOT LOCATE ON GRAPHIC WALL GENERAL CONTRACTOR. I I I q a COVERING. PROVIDE DIRECTIONAL SIGNAGE Q "_ 13. CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY IF THE TO ACCESSIBLE SE E RESTROOM A5 EXI5TIN5 COLUMN LOCATIONS AND SIZES ARE DIFFERENT FROM LINE INDICATES LEASE LINE Z PER CODE.SEE SHEET A2 WHAT OCCURS IN THESE ORAWIN65,AND OF ANY UNDOCUMENTED _ LU N.I.G. COLUMNS WHICH ARE `n LOCATED STRUCTURAL HE TENANTT SPACE CONDITIONS, DO NOT APPEAR IN THESE EXISTING TENANT DEMISING PARTITION, 50 THE DRAWINGS CAN BE REVISED TO VERIFY WALL RUNS TO UNDERSIDE OF I I ORAWIN65, CD DECK ABOVE. ACCOMMODATE THE A5-BUILT CONDITIONS. RETAIL 5ALE5 cru LEASE LINE 14. CONTRACTOR SHALL PROVIDE FIRE RATED BLOCKING/PLYWOOO N I 101 AT THE FOLLOWING LOCATIONS: TELCO RACK, INVENTORY ROOM Job Name and Number. (U I I I W6LL5,GRAS BARS,HANDRAIL5,WALL HUNG FURNITURE,WALL 2015-0131 HUNG CABINETS AND SHELVES,HANGING GLA55 WINDOW 015PLAY5 Proposed J 2 PROVIDE METAL 5TRAPPIN6 ON STUDS I AT STOREFRONTS,HANGING ro POSTERS AND AT ALL OTHER p Ab CONTRACTOR SHALL PROVIDE AND FOR MY VERIZON EXPRESS.SEE LOCATIONS WHERE EQUIPMENT 15 BEING WALL OR CEILING/50FFIT VERIZON t 3 FURNITURE PLAN FOR FIXTURE LAYOUT a IN5TALL AMICO SECURITY MESH FULL AND INTERIOR ELEVATION 3/A8 FOR ' LENGTH OF INTERIOR DEMISING WALL UP STRAPPING MOUNTING HEIGHT. 15. ALL SAW GUTS SHALL BE DOWELED ALTERNATING SIDES AT 18" Z TO 12-0A.F.F.OVER EX15TIM WALL. I , W APPLY NEW LAYER OF TYPE 5/8" 'X' PATCH AND REPAIR WALL AFTER I OR A5 PER CODE,PRIOR TO POUR BACK. STORE GYPSUM BOARD OVER MESH UP TO b' IN5TALLING 5TRAPPIN7 ON EX15TIZ WALL. (LEED) I Ib. NEW RESTROOMS.CONTRACTOR SHALL LOCATE(2)SINK-I,(U o ABOVE CEILING.TAPE AND SPACKLE A5 REQUIRED FOR NEW FINISHES. r 51NK-2,(2)AG-I AND ACCESSORIES TO COMPLY WITH ADA AND AN51.5EE ACCESSIBILITY DETAILS ON SHEET A2. 5AW GUT SLAB A I I I A5 REQUIRED FOR PLUMBING LINES w \ I 11. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE TO 5AW GUT I AND REMOVE EXISTING CONCRETE SLAB FOR TRENCHING AS Job Address: Washington ware Mall ' I REQUIRED FOR NEW PLUMBING FIXTURES;COORDINATE WITH N I ' PLUMBING CONTRACTORS TO IDENTIFY PRECISE LOCATIONS AND gton Sq PROVIDE IF NOT EXIST,NEW TENANT DEPTH IN FIELD A5 REQUIRED. VERIFY ALL OR ANY 5n;WTURAL 9585 S.W. Washington CD vii I I DEMISING PARTITION,RUN TO UNDERSIDE MEMBERS WHICH MAY INTERFERE WITH TRENCH. EXCAVATE Square Road ADDITIONAL TRENCH A5 REQUIRED TO CONNECT NEW 501L LINES ~ OF DECK ABOVE.PROVIDE TYPE 5/8" 'X' I L TO EXI5TIN6 MAIN,Y.I.F.,VERIFY WITH LANDLORD AND EXI5TIN5 Portland, OR 97223 GYPSUM BOARD ON BOTH SIDES(I-HOUR BUILDING SYSTEM FOR PRECISE LOCATION AND DIRECTION. SEE Space R05-R07 U i FIRE RATED WALL). PROVIDE AND PLUMBING PLANS. ❑ A INSTALL AMIGO SECURITY ME-5H FULL Z I DOOR DE516NATION,SEE LENGTH OF INTERIOR DEM151NG WALL UP I Drawing 11de: DOOR SCHEDULE,SHEET AIO TO 12'-0"A.F.F. SEE DETAIL b/AS NOTE: NEW 5-0"x 61'-0" FRAMELESS NEW FRAMELE55 6LA556LA55 ENTRY DOORS,SEE NEW FRAMELE55 67LA55 FREE5TANDIN6 FIXTURES ARE 5HOWN FOR CLARITY Z STOREFRONT,SEE GENERAL GENERAL NOTES FOR STOREFRONT,SEE GENERAL FOR FLOOR SLAB DEMOLITION. PLEASE REFER TO Architectural Plan o NOTES FOR SPECIFICATION SPECIFICATION NOTES FOR 5PECIFICATION ELECTRICAL PLANS FOR FLOOR BOX LOCATIONS AND _ - - - - - - - - - - - - - - - - - - - - _ - - - - - - - - - - - - - - - - - - - - - - - FURNITURE PLANS FOR FIXTURE LOCATIONS. (U Z 1 NOTE: 3 Drawn BNorth SECURITY MESH(WALL PENETRATION BARRIER) JLy. Arrow. G, TO BE SUPPLIED AND INSTALLED BY GENERAL CONTRACTOR. CU W4 Checked By. TYPE: ASM 15-qF MEDIUM SECURITY KG VENDOR: ALABAMA METAL INDUSTRIES CORPORATION,(AMIGO) Date Issued For 12/24 15 ENTRY DOORS 3245 FAYETTE AVENUE A 23'-41/2" 2 BIRMINGHAM,AL 35208 Client / < EXISTING NEUTRAL PIER FINISH,V.I.F. d FOCAL WALL 59'-7'-OVERALL A11 Landlord: 12/24/15 < FINISH WALL TO CENTERLINE OF ENTRY DOORS + TELEPHONE: 500-366-2642 EXISTING FINISHED WALL TO EXISTING FINISHED WALL WEB: WWW.AMICA-5E( [ Permit: 12/24/15 J VERIFY IN FIELD PRIOR TO CONSTRUCTION SECURITY MESH SHALL BE ATTACHED TO FRAMING MEMBERS U51N6 AMIGO Bid: 60-0 VERTICAL 3/4"BLACK REVEAL SECURA CLIPS FOLLOWING THE MANUFACTURERS RECOMMENDED SPACING OR Construction: M HEGTUi� L PLAN LEA5E LINE TO LEASE LINE CHANNEL ON BOTH SIDES,TYP. WA5HER5 IN LIEU OF SPECIFIED FASTENERS. Beds Issue: 1 ' No. Date Description Z C7 F- 0 Z rti 2 r/r Q 3 r. M .--r 0 0 (U Z III W t3 0 iQ F- 0_ w 3 Drawing Number, Q X" X Z Q Z O r, CD LLJ1 1 >U.) A4o cu 6 OF 31 PROVIDE b"METAL STUD CEILING I ' " SE 1u5MI G P05 5/85GG EOULE @ 12'-0"O.G. J015T5 AT Ib"O.G.WITH 5/8"TYPE 'X' MENSI. 6YP5UM BOARD FINISH.BOTTOM OF RESTROOM +10-0 JOISTS AT+q'-1'A.F.F.AT RE5TROOM5 108 G3 P_� G2 AGT-3 2. 8'-0'TO 10'-0"U5E 2-15/8"25 GA. MTL.STUDS® 12'-0" O.G. BERG-2 CLIP <CzNce FASTENED BACK TO BACK® EACH 51DE OF MAIN RUNNER TYPICAL. LATERAL SUPPORT POINT WHERE FIXNRE ROW 3. 10'-0"TO 15'-O'U5E 2-21/2"25GA.MTL.STUDS FASTEN SAME A5 WIRE HANGER® 4'-0" FALLS BETWEEN MAING •NOTTE#2' O.G.EACH WAY. RUNNER,USE 4'-0"LONG \ USKIN MAIN® 4'-0"O.G.A5 �i8„ PC.GR-20 4. ALTERNATE: UP TO 5'-0"USE 3/4" 0 EMT CONDUIT 2'-0"X 4'-O" CRO55 TEE. DESIGN. FP TELCO ACOUSTICAL TILE 294 Morris Avenue Springfield,NJ 07081 (TYP) " " Tel: 973.376.4411 Fax: 973.376.8989 CLEARANCE = 3/4 (CATEGORY D) www.GruskinGroup.com Ni REG 0100.9869-N 5E 15M I G CEILING NOTES: UNATTACHED SIDE FP I. ALL HANGER WIRE SHALL BE MIN.OF#12 GALV.WIRE OR GODS Thlsdocument and the Ideas and designs Incorporated APPROVED EQUAL. HVAC-AIR DIFFUSERS, herein,as an Instrument of professional service,Is the property of GRUSKIN ARCHITECTURE+DESIGN,P.C.,and 2'-0"X 4'-0" RECESSED WITH APPROVED CLIPS BERG-2 CLIP 6u Is not to be used In whole or In art for any other project 6"METAL STUDS 2. ALL HANGERS AND RUNNER5 SHALL BE ACCURATELY LEVELED AND FLUORE56ENT LIGHT OR WIRE5 A5 REQ.'D.BY M without the E+D authorization of GRUSKIN BE 5PAGED IN ACCORDANCE WITH MANUFACTURERS FIXTURES. SEE CITY STANDARDS(TYP) ARCHITECTURE N.I.G. AT I b'O.G. All Rights Reserved SPECIFICATIONS. ELECTRICAL DRAWIN65. 5E15MIG P05T OR EMT CONDUIT. ©2015 Gruskin Architecture+Design,P.C. WOMEN�S GR-20 3. ALL INTERSECTIONS AND GONNECTION AGCE550RIE5 THROUGHOUT SEE SCHEDULE.HORIZONTAL ❑ SHALL BE CAPABLE OF WITH5TANDING X516N LOADS REQUIRED BY CRO55 RESTRAINT BRACE#12 GA.WIRE 6 '•4& Kemeth A. Gruskin AIA SPL105 RESTROOM LOCAL CODES. RUNNER s ALL AIRES ATTACHED TO MAIN� YED @ 450 ATTACHED SIDE AL 5421 MT 2537 AK 13167 NC 9961 10� GR-20 RUNNER.PROVIDE HORIZONTAL CLIP C PERIMETER WALL DETAIL AR 1311 ND 1666 G5-20 ❑ +10-D�r 4. AT LIGHT FIXTURES PROVIDE 4/#12 GALV.WIRE TO BE SECURED TO RESTRAINTS BRACING ONLY IF G K'' AZ 3811 NE 1666 G2 THE GRID AT EACH CORNER OF LIGHT FIXTURES PER A5TM G 635 CA 39 2 9 NH A-3547 GR-20 + A(7-3 CEILING AREA MEETS OR2796 ❑ AND G b3b. EX( 1,000 50.FT. SEISMIC CO ARC-400347 NJ Al 09999 CT 9613 NM 004168 b"METAL STUDS INVENTOR I 5. SEE ELECTRICAL DRAWINGS AND REFLECTED CEILING PLANS FOR , LOOKING DC ARC100723 NV 5521 r LOCATIONS AND DIRE( OF LIGHT FIXTURES. SPLICE PROVIDE 2-#10 CLIP MAIN RUNNER DE 0006261 NY 025528-1 NY AT Ib O.G. 106 J�5REAK, AREA TILE 50REW5 AFTER TILE n FL GA AR91629 OK OH 13861 +10_0 + Z" PANEL 15 INSTALLED. G2 ACT-395 103 b. LIGHT FIXTURES,ELECTRICAL WIRING SYSTEM,LOW VOLTAGE WIRING HI AR 11489 OR 4899 COMPONENTS,COMMUNICATION,COMPUTER GABLES AND MAIN HANGER WIRE W/2 IA 05713 PA RA-015432-8 cA W MECHANICAL SERVICES SHALL BE INDEPENDENTLY SUPPORTED RUNNER 0 ° TURNS IN 11/2"TYP. ID AR-984459 PR 19965 GR-20 GR-20 EQUAL M EQUAL ® IL 001-019152 RI 2666 TILE TILE FROM THE SUSPENDED CEILING SYSTEM. IN AR10400066 SC 6834 ® �� ❑ ❑ +10�-0 LATERAL SUPPORT BRACE GRo55 RUNNER KS 4674 SD 11532 ELEC. ROOM G2 GR-20 GR-20 1. FOR CEILING AREAS EXCEEDING 2,500 5Q.FT.,A SEISMIC ^ NTS KY 5967 TN 101374 ACT-3 RUNNER DETAIL LA 5734 TX 17680 104 +10'-0" OPEN OFFICE K SEPARATION.JOINT OR FULL HEIGHT PARTITION THAT BREAKS THE NOTE: 12'-0 O.G.EACH WAY B NTS ME ARC 2596 UT 5881358-0301 GR-20 G2 GEILING UP INTO AREAS NOT EXCEEDING 2,500 50.FT.SHALL BE MD 11016 VT 2572 AGT-3 PROVIDED UU55 STRUCTURAL ANALYSES ARE PERFORMED OF THE MA 10635 VA 0401 011223 -�- - - CEILING BRACING SYSTEM FOR THE PRE56RIBED 5EI5MIC FORGES 6'-0' 12-0 ATTACH HEAVY DUTY T-BAR SYSTEM MN 44Ml 0120652379 WA /9004005 w ( THAT DEMONSTRATE CEILING SYSTEM PENETRATIONS AND CL05URE MAXIMUM O.G.EACH WAY TO MO A-2005029740 WV 3727 LATERAL TO STRUCTURE IN ACCORDANCE ANGLES PROVIDE SUFFICIENT CLEARANCE TO ACCOMMODATE THE SUPPORT POINT LATERAL SUPPORT WITH OREGON STRUCTURAL MS 3860 WY C-1967 ANTICIPATED LATERAL D15PLAGEMENT. EACH AREA SHALL BE 5UPPN b'-0"OF POINT SPECIALTY CODE SECTION 808 AND y` 77- MAX..AT ENDS Professional Seak 771- PROVIDED WITH CLOSURE ANGLES IN ACCORDANCE WITH ITEM B EACH WALLASCE 1.05 13.5.6 fy' AND HORIZONTAL RESTRAINTS OR BRACING IN ACCORDANCE WITH WIRE HANGER ITEM G OF A.5.G.E.1-05,SECTION 135.62.2. HORIZONTAL RESTRAINT F"77"' I/2"SPACE(TYP.) WIRE5. 8. EXCEPT WHERE RIGID BRACES ARE USED TO LIMIT LATERAL +I 2X2 EMERGENCY DEFLECTION,SPRINKLER HEADS AND OTHER PENETRATIONS ARMSTRONG A.GRUSICIN 0 - o b -� NIGHT LIGHT,TVP. THROUGH THE CEILING TILE REQUIRE MINIMUM 2-INCH RING5,SLEEVES BER62 CLIP(TYPJ `INSTALL 2'X4'ACOU5TICAL 1r �RUTAT TOP� SANA TE N METAL SUSPENSION +4899 • GR-OI OR ADAPTERS THAT WILL ALLOW A MINIMUM I-INCH CEILING G BOTTOM. HEAVY DUTY 'T"GRID IONTEM MOVEMENT IN ALL HORIZONTAL DIRECTIONS. ALTERNATIVELY,A 1/8"MOLDING A • 5WIN5 JOINT GAN BE PROVIDED AT THE TOP OF THE SPRINKLER (FTE OF WALL OR PER OREGON STRUCTURAL PPOGFIPit.[),NJ GR055 RUNNER \ _11XI HEAD EXTENSION TO ACCOMMODATE THE I-INCH MOVEMENT(A50E 1, SPECIALTY CODE SECTION DEMISING MAIN RUNNER. OBS SEG. 13.5.622) PARTITION 808 AND ASCE 1.05 133.15 � x xS ,!1tfl x HK > . I I q. SEISMIC SUSPENDED CEILING SHALL BE ARMSTRONG SEISMIC RX p LATERAL SUPPORT BRAGS 5ECTION %*1 - T] SUSPENDED SYSTEM. Consultant 0 I 0 10. THE BERC2 CLIP 15 L15ED TO SECURE THE MAIN RUNNERS AND CROSS NOTE: ® 12'-0"O.G.EACH WAY GR-01 GR-01 RUNNERS ON TWO ADJACENT WALL5 TO THE STRUCTURE AND THE LTERL SUPPORT DETAILS COMPACT FULLY RECESSED REFER 0 DETAIL Q3 FOR P-08 TWO OPPOSITE WALLS TO THE PERIMETER TRIM.A NOMINAL 1/8' EMERGENCY LIGHT FIXTURE + LIC714TIM FIXTURE LOGATIO + +< WALL MOLDING 15 USED IN LIEU OF THE 2"PERIMETER 5UPPORTING N.T.S. CENTERED IN CEILING TILE,TVP. GP OB CL05URE ANGLE REQUIRED BY SECTION gh.2.16,22(b)OF A5CE-1 RE AIL 5A E5 N I(, FOR SEISMIC DE5167N CATEGORY 'D'.EXCEPT FOR THE USE OF THE 1 1 1 BER02 CLIP AND THE 1/8"WALL MOLDING AND ELIMINATION OF OUTLINE OF FIXTURE BELOW,TYP. GR-02 / \ i I SPREADER BARS,INSTALLATION OF THE CEILING SYSTEM MUST BE r GPt08 AS PRE50RIBED A5 PER OREGON OREGON SPECIALTY CODE C> 0 0 0 0 5EGTION 808.1 GR-DI GR-01 GR-01 GR-01 GR-01 GR-0I GR-0I II. SEISMIC SUSPENDED CEILING SHALL COMPLY WITH ASCE 15EGTION cu �, 0 ,_ 135.6 OREGON STRUCTURAL SPECIALTY CODE SECTION 808 AND " GR-01 GR G 01 G -02 SHALL HAVE HEAVY DUTY T-BAR GRID SYSTEM. Job Name and Number. 2015-0131 SLJI J - x 420 12. CLIPS INSTALLED ON THE UNATTACHED WALL5 SHALL ALLOW THEProposed O GR-02 +10�-Dry R-02 TRACK LIGHT FIXTURE MOUNTED TO O �"\ G1 AGT-1 TERMINAL RUNNER END TO MOVE 3/4'FOR CATEGORY "D". w SUSPENDED CEILING AND AIM HEAD VERIZON AT FIXTURE,TYP. 00 00 OD 0 \ 0 + r z �-/ GR-01 GR-01 �i OR GR-0I r STORE UCEILING TYPE KEYS: O 'It \ I \ ,; �\\ �\ REFLEGTED GEILING KEYS (LEED) w SUSPENDED 24X24"ACOUSTIC TILE CEILING,REFER TO PLAN riv 00 GR P 2 GR-02 &OD O GI FOR CEILING HEIGHT5(AGT-U nil EQ. EQ. i '10 o TYPE DESCRIPTION V 00 0 �, O o SUSPENDED 24X48'ACOUSTIC TILE CEILING,REFER TO PLAN b'LED 2300 LUMEN DOWN LIGHT IN 3000K. 0 , Ind 0 0 G2 0 WHITE REFLECTOR,WHITE TRIM,USE IN AGT-I CEILING. GR-02 q-� GR-01 GR-01 �i GR-0 GR-0I GR-0I '- FOR CEILING HEIGHT5(ACT-3) GR-DI CENTERED FIXTURE IN TILE,TVP. Job Address 0 5-4 1 GR- 2 1/2 b"LED 2300 LUMEN DOWN LIGHT IN 3000K. WHITE Washington Square Mall I -02 I GR- 2 I G3 GYPSUM BOARD CEILING,REFER TO PLAN FOR CEILING HEIGHT5 GRD-Ola REFLECTOR,WHITE TRIM USE IN DRYWALL SOFFIT 9585 S.W. Washington 4'-o° 4'-0" S uare Road 2'-0" 2'-0" ONE-LIGHT ADJUSTABLE LED ACCENT LIGHT,22DEG q w + �' REFLECTED CEILING L I NG NOTES: NARROW BEAM,3000K,wH1T1=FINISHES.ANTI-GLARE Portland, OR 97223 OR-Ola w ' GR-Ola GR-02 LOUVER.USE IN ACT-I CEILING. Space R05-R07 � O O O O ALIGN I. ALL DIMENSIONS,ARE FINISH DIMENSIONS. ® THREE-LIGHT ADJUSTABLE LED ACCENT LIGHT, 22DEG WIDE 0 0 XI N BEAM,3000K,WHITE FINISHES.ANTI-GLARE LOUVER. z GR-01 GR-01 GR-01 GR-OI GR-01 GR-01 GR-03 Drawing Title: 2. ALL NEW SUSPENDED CEILI%5 SHALL BE AT HEI67HT5 AND LOCATIONS 6"LINER LIGHT SLOT FIXTURE WITH 3000K LED SOURCE; INDICATED ON PLANS. =1 (STANDARD LED OUTPUT)REGRESSED DIFFUSER LENS. p SEE PLAN FOR FIXTURE RUN LENGTH5. Reflected z m ENTRY DOORS 3. DIFFUSERS,GRILLES,SPRINKLER HEADS AND SPEAKERS IN ACT-I GR-04 . . o rE FOCAL WALL CEILINGS SHALL BE PAINTED TO MATCH CEILING(WHITE P-1. O O TWO-LIGHT ADJUSTABLE LED ACCENT LIGHT,22 DEG Ceiling Plan ) LOUVER. BEAM,3000K,WHITE FINISHES.ANIT-GLARE g ni' 4. ALL CEILING GRIDS SHALL BE CENTERED IN ROOMS, UNLE55 and Details ONE-GIRGUIT WHITE TRACK. z +Eou'] OTHERWISE NOTED. T-05 X SEE PLAN FOR RUN LEN6TH5. REFLECTED CEILING PLAN C3 5. FOR LIGHTING SPECIFICATIONS,SEE ELECTRICAL FIXTURE SCHEDULE. Draevney. JL Arow. 9 SCALE:1/4"=1-0" INTEGRAL LED WALLWASH TRACKHEAD IN 3000K.WHITE FINISHES. Checked By. b. SPRINKLER HEADS SHOWN ARE FOR DIAGRAMMATIC PURPOSES ONLY T-01 KG Cl�0 AND ARE NOT MEANT TO REPRESENT AN ENGINEERED SYSTEM.ACTUAL 5Y5TEM SHALL BE DE516NED BY A LICENSED FIRE 5UPPRE55ION SMALL DECORATIVE PENDANT HAVANNA 1I CHROME Date Issued For ra Client: 12/24/15 CONTRACTOR A5 PER NFPA 13,LOCAL ORDINANGE5 AND THE GP-OS FINISH,LED SOURCE. BOTTOM OF FIXTURE AT 1'-0"A.F.F. Landlord: 12/24/15 REQUIREMENTS OF THE LANDLORDS INSURANCE CARRIER.TENANT EMERGENCY EXIT SIGN. Permit: 12/24/15 SHALL USE LANDLORDS SPRINKLER CONTRACTOR FOR ALL J DOORS +E EQ. EQ. HELD TIGHT TO GRID SPRINKLER WORK IF REQUIRED BY OWNER �- 'XI"- FOR SALES AREA; "K' -FOR OPEN OFFICE; gid; FOCAL WALL "E" -EXISTING TO REMAIN If - RELOCATED. Construction: Li 1. IF APPLICABLE SPRINKLER HEADS IN ACT-1 CEILIN65 SHALL BE FULLY MINI GENIE 5ERIE5 COMPACT FULLY RECESSED ReNislon Issue: Q EQ. EQ. eS es CONGEALED AND(ENTERED IN CEILING TILE. EMERGENCY LIGHT.CONFIRM FIN15H WITH CEILING No. Date Description "' EM PLANS(BLACK OR WHITE) 0 w 8. AMPLIFIERS AND VOLUME CONTROL FOR RETAIL SALES 5PEAKER5 2 X 2 LED LIGHT FIXTURE. z SHALL BE LOCATED IN TELCO ROOM. CONFIRM LOCATION WITH "CR-20' -USED IN 51,15PENDED CEILING. GENERAL CONTRACTOR AND VERIZON HIRELE55 PROJECT MANAGER '05-20"-USED IN 6YP5UM BOARD CEILING. z GP OS o I OR-1 GR-03 OR GR-15 BEFORE INSTALLING. ALL PLAYNETY40RK SPECIFICATION5 PROVIDED 2 X 2 EMERGENCY E6RE55 LED FIXTURE. Z U.O.N. U.O.N. BY REGIONAL VENDOR SHALL BE VERIFIED BY VERIZON WIRELE55. WIRE FOR NIGHT LITE. 3 "GR-20-EM"-USED IN SUSPENDED CEILING. N oEQ EQ EQ. EQ. q. SEE SHEET AIO FOR FINISHES "G5-20-EM" -USED IN 6YP5UM BOARD CEILING. "' GP OS HELD TIGHT TO GRID ~ 10. LIGHTS TO BE CENTERED IN ACOUSTICAL CEILING TILE,UNLESS NOTED Q HELD TIGHT LAY-IN SUPPLY GRILLE.SEE MECHANICAL PLANS In TO GRID OTHERWISE l LU tL I UA ❑ ❑ z o 11. ALL EMERGENCY FIXTURES SHALL BE A5 PER STATE AND LOCAL LU I �w GORES TYP LAY-IN RETURN GRILLE.SEE MECHANICAL PLANS CL LU - �3 I v~,A EXHAUST FAN 3 GR-2 x W LIGHT PLACEMENT DIAGRAM U.O.N Drawing Number. DIAGRAMMATIC SPRINKLER HEAD.SPRINKLER HEAD IN ACT-I CEILING5 SHALL BE CENTERED IN CEILING TILE. z¢ FOR GP-OS FIXTURE LIGHT PLACEMENT DIAGRAM C C SCALE: SCALE: 1/4"=1'-0' >0 OS SPEAKERS, CENTERED IN GEILING TILE,TYP. io to 7 OF 31 FURNITURE PLAN SHALL NOT BE USED FOR CONSTRUCTION OR PANIC HARDWARE BY CABINETRY. IT SHALL BE CONSIDERED A LOCATION PLAN ONLY. SECURITY VENDOR(TYPJ FOR TELCO LAYOUT,SEE ELECTRICAL e GR DRAWINGS FOR MORE INFORMATION. FURNITURE NOTES: FIXTURES - KEYED NOTES D � _ I. ALL MOVABLE FURNITURE SHALL BE PROVIDED BYGUS IN SEG VERIZON WIRELE55.ALL OTHER FURNITURE ITEMS(IE. 5X-015 E55ENTIAL5 PEDESTAL SHORT WITH LIVE DEVICE GR 77 77 o COUNTERS,CABINETS,ETC.)SHALL BE THE CABINET X-01 E55ENTIAL5 PEDESTAL MEDIUM WITH LIVE DEVICE ARCHITECTiJ• CONTRACTOR'S RESPONSIBILITY. JI? 294 Morris Avenue Springfield,NJ 07081 TELCO 5x-o2 FEATURE CUBE WITH LIVE DEVICE Tel: 973.376.441 1 Fax:973.376.8989 � SEN 5ES 109 2. VERIZON WIRELE55 MUST COMPLY WITH ALL FEDERAL, 5X-05 www.GruskinGroup.com NJ REG 0100.9869.14 \ ' STATE AND LOCAL AC-CE551BILITY REQUIREMENTS FOR O ACCESSORIES WALL RESTROOM DG ALL EMPLOYEES AND THE PUBLIC,WITH RESPECT TO This document and the Ideas and designs Incorporated X-06 AIRELE55 WORKSHOP herein, as an Instrument of professional service,Is the FP N.I.G. / 108 / ALL FURNITURE,FIXTURES,DISPLAYS AND 516NA5E property of GRUSKIN ARCHITECTURE+DESIGN,P.C.,and \� WHICH THEY PROVIDE. 5X-07 BRAND MONOLITH is not to be used In whole or In part for any other project written authorization of GRUSKIN ♦ \ / I 3. CONTRACTOR SHALL VERIFY LOCATION,UNIT AND 5X-15 DEVICE 015PLAY WALL WITH LIVE DEVICE ARCHITECTURE+DESIGN,P.C. All Rights Reserved - - ' REQUIREMENTS OF FREESTANDING 015PLAY5 WITH REFRIGERATOR(ENERGY VERIZON WIRELE55.USE ELECTRICAL POWER PLAN TO 5X-16 P05 STATION (D 2015 Gruskin Architecture+Design,P.C. STAR)SUPPLIED AND _ INVENTORY LOCATE NON-MOVABLE FURNITURE. X 16ADA P05 STATION ADA Kenneth A. Gruskln AIA INSTALLED BY G.G. AL 5421 MT 2537 13W TASK LIGHTING PROVIDED ♦ / 106 21 Aq 4. ALL FURNITURE PARTITIONS SHALL BE U.L.RATED 5X-20 MY VERIZON EXPRE55 COUNTER AK 13167 NC 9961 AT DESK BY VERIZON COUNTER-TOP PRINTER � / �� � (LISTED). 5X-21 VERIZON SERVICES PANEL AR 3811 ND 1666 WIRELE55.(NP OF 3) INVUE CHARGER AND / / WOM NQS TABLET CHARGING X < STATION AZ 39209 NE A-3547 D o PROGRAMMER RESTROOM 5. INVENTORY SHELVING SHALL BE SUPPLIED AND CA C-29898 NH 2796 MANAGER "' \ \ IN5TALLED BY GENERAL CONTRACTOR. X 2`Mh MON T R AND WITH LIVE DEVICE CO ARC-400347 NJ Al 09999 32'LGD SECURITY MONITOR 10� MOTION SENSORS )) CT 9613 NM 004168 ABOVE THE MANAGER'S DESK. 105 C0 O ABOVE THE INVENTORY 5X-23 SMART ZONE FREESTANDING DISPLAY WALL WITH LIVE DEVICE DC ARC 100723 NV 5521 �., ? �-- �� 1) _ J5 b. ALL SYSTEM FURNITURE SHALL BE GREENGUARD DE 0006261 NY 025528-1 NY MONITOR SHALL BE CENTERED ON - CEILING PROVIDED AND FL AR91629 OK 04895 THE DESK AND CENTER OF REF _ _ _ L - -I - _ - -I - INSTALLED BY VZW D Aq CERTIFIED. 5X-24 SMART ZONE FREESTANDING DISPLAY WALL GA RA011 D75 OH 13761 GOMPRE55ED WITH LIVE DEVICE AND TOUGH SCREEN HI AR 11489 OR 4899 ILIA - -� - - 1 SECURITY VENDOR 1. CONTRACTOR SHALL COMPLETE THE WOOD SUBMITTAL X-3q- STRAIGHT BENCH -2 SEATER IA 05713 PA RA-015432-B MONITOR SHALL BE AT 65"A.F.F. � - ,�, BREAK AREA 4 3 CONTRACTOR SHALL IN5TALL FORM FOR ALL WOOD PRODUCTS.A COPY OF THE ID AR-984459 PR 19965 LOCATE DURESS BUTTON PER IL 001-019152 RI 2666 MANAGER'S DIRECTION ,-,W-_' A9 Aa IS"DEEP ADJJSTABLE FORM CAN BE FOUND ON THE LEER PROTOTYPE GREEN X-46 BRAND FOCAL WALL LIGHTBOX gbX84 103TABLE WITH CHAIRS BY SPECIFICATIONS. IN AR10400066 SC 6834 LAMINATE SHELVING AND PEG KS 4674 SD 11532 VERIZON WIRELE55 EMPLOYEE LOCKERS BOARD(�) 5X-15 W1RELE55 WORKSHOP STOOL KY 5967 TN 101374 ELEG. ROOM EP EP EP H.R.BOARD BY VERIZON 42"LCD MONITOR(SMART BOARD) 2 (METAL) 8. CONTRACTOR SHALL PROVIDE PRODUCT INFORMATION LA 5734 TX 17680 '771 WIRELESS,HEAD s +1'-0"A.F.F. 48'WIDE LATERAL FILING A9 FOR EACH WOOD PRODUCT,HIGHLIGHTING THE ME ARC 2596 UT 5881358-0301 104 MD 11016 VT 2572 CABINET BY VERIZON WIRELE55 FLOOR COPIER BY B 5TOR. (LG) CONTENT. AND/R P05T-INDUSTRIAL RECYCLED FURNITURE KEY NOTES: MA 1 635 A 0401 011223 5B VERIZON WIRELESS DG CONTENT. MI 1301052379 WA 10344 MARKER BOARD BY VERIZON BULLETIN BOARD BY VERIZON MN 44326 WI 9900-005 OPEN 01=1=1GE lO. FULL P05 STATION WIRELE55,HEAD e +T-0"A.F.F. q. CONTRACTOR SHALL PROVIDE M5125 FOR ALL MO A-2005029740 WV 3727 WIRELESS,HEAD® +1'-0"A.F.F. GR MS 3860 WY C-1967 102 SEG I COMPOSITE WOOD ADHESIVES,HIGHLIGHTING THE VO( O IPAD STATION r' CONTENT. CONTRACTOR SHALL COMPLETE THE VOG Professional Seal: INVENTORY ROOM 15 ON 5EPARATE Aa SUBMITTAL FORM FOR EACH PRODUCT USED. A COPY O BILL PAY K105K TB07LELE55KATER X-46 ALARM KEYPAD.ROLLING SECURITY OF THE FORM GAN BE FOUND ON THE LEED OOLER BY YERIZON SiiJTTER MAY ONLY BE CLOSED PROTOTYPE GREEN SPEGIFIGATIONS. ® FIXTURE 15 TO BE SCRIBED AROUND EXISTING STRUCTURE IRELE55 - - - - - - - - - - - MANUALLY WHEN ALARM 15 ACTIVATED. BULB STORAGE CABINET BY A.GRUSKIN 5X-15 \ CABINET CONTRACTOR EXISTING COLUMN ENERGY STAR EQUIPMENT SHALL BE 5ELEGTED 4899 tip\ 4 4 TO REMAIN \ PIR N.I.G. WHERE APPLICABLE A \ PgiNGFIELD,NJ X-01 X-01 I 5X-015 5x-01 r 5X-015 r I X-01 / \ GR = ry SECURITY/SAFETY KEY `� o£ Xt I I X-01 I I X-01 4 AS PER VERIZON WIRELESS CORPORATE SECURITY GUIDELINES. �- � ALL SPECIFICATIONS SHALL BE VERIFIED BY VERIZON WIRELESS :f11 1 .11 4'-0" 4'-0" 4'-0" 6'-1" b'-'1" 4'-0" 5'-31/2" O s BF'K I SECURITY VENDOR Consultant X-21 — GR (ARD READER,HD PROXPRO 5355 X-06 3-g X-16till ADA 2 I E5 ELECTRIC STRIKE,EQUAL TO LOGKNETI05 `1000 SERIES 24 VOG 5X-16 OI DG DOOR CONTACT EQUAL TO LOGKNETI(5 310 SERIES o o X-16ADA I 5X-20 � � � � � OD � � PIR PROXIMITY READER,EQUAL TO DETECTION SYSTEMS 051511 I O O I SEG SECURITY KEYPAD RETAIL SALES 0 5X 22M T I 101 ©�D OURE55 BUTTON,EQUAL TO KNIGHT PLASTICS LTD.MODEL KPI5 01I �� C� WITH INTEGRAL TAMPER CD J \ Imo/00 SECURITY NOTE: VENDOR TO CONFIRM LOCATION AND CONDITION OF ALL SECURITY HARDWARE ON EXISTING EXTERIOR DOORS. N 5-51/2" 8'-0 1/2" 3'-5 1/2" 8'-1 '1116" REUSE EXISTING HARDWARE IF POSSIBLE. i 8'-11/2" 3'-51/2" i Job Name and Number. 4 N 2015-0131 rT 5X-01 I 17 METAL LOCKER SPECIFICATION: Proposed GAE�I� 4LA21DVERIZON OVERALL SIZE: 12 W X 15 D X 18"H TYPE: I WIDE,b OPENING O _ _ _ TIER: b STORE 5 -05 00/ / /^\ /^\ \ \O ry 5 -05 COLOR: GRAY, / O MANUFACTURE MODEL: #B56-121512-IMG (LEED) CATALOG PG: 2334 Ul FULL 51ZE REFRIGERATOR // KENMORE#46-68882 -WHITE o \ u, 51ZE: 2q 5/8'K x bb 1/2"H.x 321/8"D. to \� s d� 5X-02\�// / s ENERGY STAR COMPLIANT TO BE SUPPLIED lob Address oI AND INSTALLED BY THE GENERAL Washington Square Mall (U -10" ''-5" 3'-0" CONTRACTOR. 9585 S.W. Washington CD uare Road Z MIGROWAVE(MEDIUM 51ZE)- Portland, OR 97223 w X 3q- X 3q SHARP#204g12 WHITE 51ZE: 21 1/8" K X 121/2" H.X 11 I/8"D. Space R05-1307 0SUPPA ,n I LRAL CONTRACTOR D BY THE GENERAL z ' Draiving Tide: MICROWAVE(LARGE SIZE) U SHARP#R403JK-BLACK Furniture and SIZE: 2121/32"K X 12 3/8" H.X 181/16"D. z DG DG TO BE SUPPLIED AND INSTALLED BY THE U I GENERAL CONTRACTOR Security Plan c , Curan Details L3 ENTRY DOORS 3 d FOCAL WALL Drawn By. North Arrow. A JL CU U TH15 DOOR 15 ALWAY5 UNLOCKED Checked By. FROM BOTH SIDES.THE DOOR'S b" KG i o b.. ca SCALE: 1/4"=1'-0" H Client 12/24/15 CARD READER 15 INSTALLED FOR PIR [)are Issued SECURITY CHIME PURPO5E5 ONLY. EXIT MOTION WHEN CARD 15 NOT USED,THE 11 Landlord: 12/24/15 DOOR WILL CHIMED TO ALERT DC DC Permit: 12/24/15 EMPLOYEES.PROXIMITY READER Bid: iv CANCELS CHIME FROM OTHER SIDE. Construction: BOTTOM OF 10'-0" BOTTOM OF h 10'-0" BOTTOM OF 10'-0" BOTTOM OF OIL 10'-0" BOTTOM OF OL 10'-0' / Revision Issue: j Na Date Description 5U5P.CEILING 5U5P.CEILING 5U5P.CEILINGTOP OF `1'-0" 5U5P.CEILING 5U5P.CEILING 18°XIS'ONE- WAY --LINE OF WALL ___ LINE OF WALL FIXTURE INE OF WALL INE E KALL GLA55 VISION PANEL o SCREW FIXTURE DIRECTLY PROVIDE 8"HIGH 20 GA .� 12 20 GA HORIZONTAL -----OUTLINE OF FIXTURE.SEE LD INTO STUDS THROUGH THE LINE OF FIXTURE.SEE 51RAPPING ON STUDS. HORIZONTAL STRAPPING ON z / FIXTURE PLAN FOR MORE = BACK OF THE FIXTURE FIXTURE PLAN FOR MORE COORDINATE WITH FIXTURE STUDS AT MONITOR BRACKET _m INFORMATION.COORDINATE GR 3 INFORMATION.COORDINATE VENDOR FOR ADDITIONAL OUTLINE OF FIXTURE.SEE FIXTURE LOCATION,COORDINATE W/. O GR VZW PRO.IEGT MANAGER POWER AND DATA LOCATIONS POWER AND DATA STRAPPING REQUIREMENTS. PLANS FOR MORE INFORMATION. W/FIXTURE GONIIZAGTOR \-E-1E(TRIG DOOR SUPPORT PANEL LOCATIONS W/FIXTURE COORDINATE POWER AND DATA 11 CD CONTRACTORo ---OUTLINE OF FIXTURE.SEE LOCATIONS W/FIXTURE CONTRACTOR. LL MOUNTED SMART BOARD, ;; MONITOR 8" STRIKE INE OF WALL FIXTURE PLAN FOR MORE CENTERED AT bb A.F.F. 8" SCREW FIXTURE DIRECTLY INFORMATION.COORDINATE - 48"LATERAL FILE CABINET II cu ANCHOR BOTTOM OF FIXTURE AGGE550RY WALL FIXTURE INTO STUDS THROUGH THE POWER AND DATA SCREW FIXTURE DIRECTLY Z BACK OF THE FIXTURE COORRDIINAT CONCRETE NTH FIXTURE INTO 5TUD5 THROUGH THE o LOCATIONS W/FIXTURE BACK OF THE FIXTURE W / CONTRACTOR. CONTRACTOR A FIN15HED h 0'-0" FIN15HED 0'-0' FINISHED D'-0" FINISHED 0'-0" FINISHED 0'-0' FIN15HED 0'-0' W Z FLOOR FLOOR FLOOR FLOOR FLOOR FLOOR 3 11 :D Dravdng Number, Z Q AGGE55ORY WALL VERIZON SERVICE PANEL DEVIGE D15PLAY WALL BRAND MONOLITH (5X-7) SMART BOARD HOME SOLUTION WALL PANEL SINGLE DOOR 1N/ PROXIMITY SINGLE DOOR W/ ELEGTRIG - „- 4 „- 6 „_ -� OR CONTACT STRIKE DOOR CONTACT �o MOUNTING DIAGRAM MOUNTING DIAGRAM MOUNTING DIAGRAM MOUNTING DIAGRAM MOUNTING DETAIL MOUNTING DIAGRAM READ��2q > SCALE: 1/4'-1-0CALE. 1/4 -1-05GALEi/4 -1 0 SCALE. 1/4 -1-0 !o CU 8 OF 31 WALL FINISH NOTES: FLOOR FINISH NOTES: FLOOR FIN15H PATTERNS: I. PROVIDE CORNER GUARDS ON EXP05ED CORNERS I. ALL DIMEN51ON5 ARE FIN15H DIMENSIONS. TELCO AS INDICATED IN RETAIL SALES.SEE CORNER oq GUARD SPECIFICATION ON SHEET AIO 2. CONTRACTOR SHALL VERIFY ALL DIMEN51ON5 PRIOR G-1 1OO • GG-1 FOR EXP05ED CORNER WITH P-b FIN15H TO ORDERING MATERIALS CARPET TILES RESTROOMS TO RECEIVE NEW VINYL WALL FLOOR BASE • 66-2 FOR EXPOSED CORNER WITH P-1 FIN15H (C-I INSTALLED IN A5HLAR PATTERN) SHEET FLOORING(V5F-1). FLOORING P-q SLAB B-3 • C6-3 FOR EXP05ED CORNER WITH P-8 FIN15H 3. SEE FIN15H 50HEMLE FOR 5PECIFI6ATION5 TO WRAP UP WALL b'MIN.ALL SIDES. 2. PROVIDE AGROYYN OR FRP CORNER GUARDS ON 4. CARPET PRODUCGRUSKIN T r THE REQUIREMENTS OF ' ' r _ �� � _' •— EXP05ED CORNERS AS INDICATED IN OPEN OFFICE. GRI GREEN LABEL PLUS PROGRAM. 294 Morris Avenue Springfield,NJ 07061 Tel: 973.376.441 1 Fax: 973.376.8989 a 3. PROVIDE AC-I TO+48"A.F.F.,1YP. 5. ANY SUBSTITUTIONS TO THE CARPET PRODUCT PT-6 www.Grusl<!nGroUp.com NJ REG 0100.9869-14 SPECIFIED MUST MEET THE LEED REQUIREMENTS LISTED PORCELAIN TILE PAINT TELCO CONCRETE SLAB FLOOR 4. PROVIDE WG-I BETWEEN$AGKSPLASH AND BOTTOM ON THE LEED PROTOTYPE GREEN SPECIFICATIONS. This document and the Ideas and designs Incorporated FP WITH 13EHR PREMIUM TWO PART EPDXY OF UPPER CABINET AT LAMINATE COUNTER herein,as an Instrument of professional service,Is the MEN'S RE5TRM. property of GRUSKIN ARCHITECTURE+DESIGN,P.C.,and 108 GARAGE FLOOR COATING LOGATIDN,IYP. 6. ALL CARPET AND CARPET PAD ADHESIVES SHALL Is not to be used In whole or In part for any other project ' M505#TAN 4155 HAVE LE55 THAN 50 G/L VOCS 5L 4B without the written authorization of GRUSKIN WALL FLOOR BASE , ARCHITECTURE+DESIGN,P.C. FP FINISH: SEMI-GLO55 5. BASE IN RETAIL 5ALE5 AREA TO BE INSTALLED EXP05ED CONCRETE SLAB-SEALED All Rights Reserved P-9,WG-1 V5F 1 V5F 1 AFTER PERIMETER FIXTURES HAVE BEEN INSTALLED. 1. ALL HARD 5URFAGE FLOORING KJST BE If A5 ©2015 Gruskin Architecture+Design,P.C. COMPLIANT WITH THE REQUIREMENTS OF THE V5F-1 b. PAINT DOORS d FRAMES IN SALES AREA TO MATCH FLOOR5GORE STANDARD A5 5HOWN WITH TESTING BY VINYL SHEET FLOORING Kenneth A. Gruskfn AIA ADJACENT WALL FINISH,HEAVY DUTY WASHABLE AN INDEPENDENT THIRD PARTY. SEMI-GL055. AL 5421 MT 2537 PROVIDE WC-1 TO+48'A.F.F. AK 13167 NC 9961 ALL WALLS IN RESTROOMS I 8. CONCRETE FLOOR FINISHES SUCH A5 SEALER,STAIN AR 3811 ND 1666 INVENTORY 1. PAINT DOORS AND FRAMES IN NON-5ALE5 AREA AND FIN15H KU5T MEET THE REQUIREMENTS OF SOUTH AZ 39209 NE A-3547 106 P-q,HEAVY DUTY WASHABLE SEMI GLASS. COAST AIR QUALITY MANAGEMENT DISTRICT(56AQMD) CA C-29898 NH 2796 VyALL FLOOR BASE RULE 1113,ARCHITECTURAL COATINGS,EFFECTIVE CO ARC-400347 NJ Al 09999 MANAGER WOMEN'S RESTRM. P-q G-1 B-3 8. GG TO PREP WALL AS REQUIRED FOR DIGITAL JANUARY I,2004. SEE CHART ON THE LEER CT 9613 NM 004168 105 NV 5521 '1 GRAPHIC WALLCOVERING.LEVEL 5 WALL FINISH, PROTOTYPE GREEN SPECIFICATIONS. DE 006261DC 23 NY 025528-1 NY WALL FLOOR BASE WALL FLOOR BA5E PRIME WITH MANUFACTURERS RECOMMENDED FL AR91629 OK 04895 P-9 C-1 B-3 PfAC 1 I V5F-1 I V5F-1 PRODUCTS TINTED TO MATCH WALLCOVERING. q. TILE 5ETTI%ADHESIVES AND GROUT KJ5T MEET SOUTH GA RA011075 OH 13761 HI AR 11489 OR 4899 COAST AIR QUALITY MANAGEMENT DISTRICT(50AQMD) IA 05713 PA M-01 5432—B q OMIT WALL BASE BEHIND ALL MILLWORK WALL THE LEED PROTOTYPE RULE II68. SEE CHART ON TYPE ID AR-984459 PR 19965 G1 015PLAY UNITS. ALL MILLWORK WALL DISPLAY IL DDI—019152 RI 2666 GREEN SPEGIFIGATIONS --- I UNITES COME WITH APRE-INSTALLED BASE. IN AR10400066 SC 6834 PR)VIDE -1 BET BAG LA5H KS 4674 SD 11532 BOTTO CABINET AT KY 5967 TN 101374 BREAK AREA LAAINATE COUNTER LC CATION I 10. ALL PAINT COATINGS,PRIMER5,5EALER5,CLEAR LA 5734 TX 17680 103 PRO TO+48'A.F.F. I WOOD FINISHES AND 5HELLA05 SHALL MEET THE ME ARC 2596 UT 5881358-0301 WALL FLOOR BA5E UNLESS OTHE .15E NO VOG LIMITS SPECIFIED UNDER INDOOR AIR QUALITY -_ MD 11016 Vi 2572 ELEG. ROOM P-a,wG-i G-t B-3 MANAGEMENT ON THE LEEP PROTOTYPE GREEN MA 10635 VA D401 011223 GJ ESTIMATED 50UARE FOOTAGE5 FOR MI 1301052379 WA 10344 104 I I OPEN OFFIGE I SPEGIFIGATIONS. FLOOR FIN15HE5. CONTRACTOR MN 44326 WI 9900-005 WALL FLOOR BASE _ I MO A-2005029740 WV 3727 MS 3860 WY C-1967 P-ci SLAB B-3 WALLI FLOOR I BA5E SHALL FIELD VERIFY. P-q,wG-t —C-TT FINISH KEY: CARPET (G-i) 225 5F Professional Seal: PAINT TELCO CONCRETE SLAB FLOOR WITH BEHR PREMIUM TWO PART EPDXY — — — — — — — — — — — — W DUTY ACROVYI I CORNER FINISH SYMBOL,REFER TO GARAGE FLOOR COATING FOG WALL WALL P-8 GIJ RD5 AT T51DE ORNERS 0 FINISH SCHEDULE X-X M595#TAN 4155 L: P-1 �----BA5E:HALL: PF -1 0 1 WALL PFK/P-1 MATCH WG-I RING IN FINISH: SEMI-GLOSS B E: B-I B-I BASE: B-I BASE: 1 BASE B-I HE CHT,TYP. . RUSIQN L: P-b CARPET TILE LAY STAR 1'-0" v-a' �45� :A FRP OR WC-I FIN15H ON WALL �— E: B-I POINT N5 IN A5HL PATTER PERM ACTURE � .) � ,% 4899 TION ME i FLOOR FIN15H TRM51TION �. PRINGFIELD,NJ BA E: B-I CORNER GUARDS OF IV' y, P_b PFW-PAINT WALL FROM CEILING Consultant CO R GU GG-I WALL P-1 DOWN 12"AND WHERE EXP05ED TO (TYP. T P-6 F11115HED L) B B-I B-I 12"BEHIND WALL FIXTURE. r REFER TO SHEET AIO FOR FINISH SCHEDULE r r i 1 RETAIL SALES N 10 I G-1 i WALL FLOOR BASE Job Name and Number. 2015-0131 -t, P-b,P-1, G-1,PT-6 B B-4 P-b PT-6 Proposed i W VERIZON z m STORE W A (LEED) L7 r I C) I Job Address C Washington Square Mall `. 9585 S.W. Washington CD r Square Road Portland, OR 97223 Z Space R05-1307 U 0 ca WALL: P- L: P-6 o BASE: -5 B DrawingTlde: b'H.RAISED PLA ORM. GRAY MP051TE ALIGN z PANEL( -6 Finish Plan CUBASENm AL1 PT-b : PT_ LZand Details L3 MALL TILE(TO MATCH EXI5TIN6) 3 REPLACE ENTIRE ROW OF COMMON DrawiBy. North TILE WHERE REQUIRED FOR JL Arrow. Q DEMOLITION(NO PATCHING OF ENTRANCE DOORS MALL TILE(TO MATCH EXI5TIN6)REPLACE MALL TILE(TO MATCH EXISTING) REPLACE Checked By. 11 INTERMITTENT TILE WILL BE ALLOWED) AND FOCAL WAIL ENTIRE ROW OF COMMON TILE WHERE ENTIRE ROW OF COMMON TILE WHERE KG YNALL AND FLOOR FIN15H PLAN REQUIRED FOR DEMOLITION(NO PATCHING OF REQUIRED FOR DEMOLITION(NO PATCHING OF Date Issued For A 1 INTERMITTENT TILE WILL BE ALLOYED) INTERMITTENT TILE WILL BE ALLOWED) Client: 12/24/15 SCALE: 1/4"=t'-0" Landlord: 12/24/15 Permit: 12/24/15 1 Bid: f PORCELAIN TILE(PT-6) Construction: w MALL TILE(TO MATCH EXISTING) Revision Issue: REPLACE ENTIRE ROW OF COMMON TILE 1/8"THICK 5ATIN ANODIZED ALUMINUM ANGLE, No. Date Description e WHERE REQUIRED TO BE REMOVED FOR '50HENE"#AEI00(VERIFY HEIGHT A5 REQUIRED) 0 DEMOLITION(NO PATCHING OF INTERMITTENT BY SCHLUTER SYSTEMS, TILE WILL BE ALLOWED),SEE PLAN TEL: (800)412-4588,OR APPROVED EQUAL BURKE MERGER MOULDING BURKE MERGER MOULDING LD #110 OR EQUAL, #110 OR EQUAL, ALUMINUM ANGLE CARPET TILE(C-I) COLOR: 502 BROWN COLOR: 502 BROWN LINE OF FINISHED WALL 3 CARPET TILE(G-)� C,ONCRE E 5L CARPET TILE(G-I)� VINYL SHEET FLOORING(V5F-U LINE OF FINISHED MWALL 41/8" VINYL SHEET WHITE MARBLE SADDLE CD FLOOR(V5F-1) r, Cd i o CONTRACTOR SHALL FEATHER IN FLASHING A MINIMUM OF LINE OF EXISTING LINE OF EXISTING W 3 24"ALL AROUND HIGH POINT(OR AS REQUIRED) TO KEEP CONCRETE SLAB CONCRETE SLAB o A A SMOOTH AND FLUSH TRANSITION a w z LINE OF EXI5TIN6 UNFINISHED FLOOR 3` MALL TILE TO PORCELAIN TILE (PT-6) DraxingNumber: X�- Z¢ TO �1ETPTILE (G-1) DETAIL GRPET TILE (G-1) TO SLAB GRPET (G-1) TO VINYL SHEET FLOORING (V5F-1) VINYL SHEETFLOOR (V5F-1) TOGRPTTILE (G-1)o FULL SCFULL SCALE FULL SCALE FULL SCALE WI > , A7 !o tv 9 OF 31 SUSPENDED ACOUSTIC TILE CEILING COLUMNN SUSPENDED ACOUSTIC TILE CEILING AT+10'-0'A.F.F.(ACT-1) P-1 PAINT P-1 PAINT AT+10'-0'A.F.F.(ACT-1) BOTTOM OF SU5P. 10'-0" BOTTOM OF 5U5P. � 10'-0' P-1 PAINT � CEILING P-D CEILING CB RAND FOCAL WALL FLUSH DOOR WITH METAL LIGHTBOX 'D FRAME.PAINT DOOR AND _ FRAME 5EMI-GL055.MATCH ............ p -� J-BOX -� ADJACENT WALL FINISH P-b GRUSKIN MONITOR AR(.HITEC C. - PFW 4 Ll PFW 294 Morris Avenue Springfield,NJ 07081 � _ � \ Tel: 973.376.441 I Fax: 973.376.8989 -_ 2'-0" ! www.GruskinGroup.com NJ REG 0100.9869.14 This document and the ideas and designs Incorporated f - — herein,as an Instrument of professional service.Is the I FINISHED FLOOR D'-O' � ! property of GRUSKIN ARCHITECTURE+DES IGN,P.C.,and „ Is not to be used In whole or In part for any other project - - FIN15HED FLOOR 0-0 without the written authorization of GRUSKIN 5X-05 B-I BASE AT X-22M 5X-21 FIRE EXTINGUISHER B-4 BASE AT X-46 PAINT A 3bX24 AREA B-I BASE AT ARCHITECTURE+DESIGN,P.G ts Reserved P-b FINISH,TYP. 6-I BASE ,T NP. P-8 FINISH,TYP. AROUND OUTLET WHITE(P-1) P4FINISH,TYP. ©2015 Gruskin Architecture+Desi P-1 FINISH, Design, P.C. 1 INTERIOR ELEVATION 2 INTERIOR ELEVATION Kenneth A. Gruskin AIA LE: 1/4"=1'-0" SCALE: 1/4"=1'-0" AL 5421 MT 2537 AK 13167 NC 9961 10 1/2" —LINE OF ROUGH AR 3811 ND 1666 56PENDED ACOUSTIC TILE CEILING R,O, OPENING AZ 39209 NE A-3547 BOTTOM OF 5U5P. ID'-0° CA C-29898 NH 2796 AT+10-0 A.F.F.(ALT-1) F XTUIRES e KEYED NOTES CO ARC-400347 NJ Al 09999 NM 004168 DC 9613 723 NV 5521 GE L NG 5X-05 ACCESSORIES WALL CT 9613 DE 0006261 NY 025528-1 NY FL AR91629 OK a4895 GA RA011075 OH 13761 5X-15 DEVICE DISPLAY WALL HI AR 11489 F OR 4899 5X-20 MY VERIZON EXPRESS 4HOPELINE COUNTER IA 05713 PA RA-015432-B CP--bD ID AR-984459 PR 19965 P 5X-21 VERIZON SERVICE PANEL �' IL 001-019152 RI 2666 IN AR10400066 SC 6834 KS 4674 SD 11532 FN-05 STRAIGHT BENCH-2 SEATER KY 5967 TN 101374 LA 5734 TX 17680 FULL INSULATION(TVP) ME ARC 2596 UT 5881358-0301 X-46 BRAND FOCAL WALL LIGHTBOX gbX84 u�z 10 1/2" MD 11016 Vi 2572 MA 10635 VA 011223 ® Q R.O. 5/8"GYPSUM BOARD(TYP.) 0401 MI 1301052379 WA 10344 0401 MN 44326 WI 9900-005 ( MO A-2005029740 WV 3727 FIN15HED FLOOR OIL 0'-0° MS 3860 WY C-1967 BPK 5X-20 20"HIGH 20 GA.HORIZONTAL '\—B-1 BASE AT Professional Seal: / METAL STRAPPING ON 5TUD5 AND P-b FIN15H,TYP. CENTER VERTICALLY ON FIXTURE. ATT` 3 5/8"METAL STUD S PER INTERIOR ELEVATION �� MANUFACTU H FIXRSA SPECIFICATIONS 3 SCALE: 1/4"=1'-0" LARSEN AL-G240q-R CABINET. H.A.GRUSKIN SEE ARCH PLAN FOR HINGE ORIENTATION.SPECIFY ORIENTATION 4899 WHEN ORDERING. CONTINUOUS IP TRACK WITH 2" EXI5TING METAL DECK SPRINGFIELD,NJ 5L ELEVATION FOR PLAN DETAIL FOR *�, FLANGE.WITH#8 SCREWS �l'� FIRE EXTINGUISHER CABINET FIRE EXTINGUISHER G,�BINET of v� BOTTOM OF EXISTING OL VARIES SCALE: 1"=1'-0" � SCALE: 1"=1'-0" BOTTOM OF EXISTING VARIES METAL DECK Y.I.F. Donsulrant: ry _1F_ METAL DECK V.I.F. EXISTING OPEN WEB STEEL J015T(TYP.) PROVIDE GAP BETNEEN PROVIDE UNISTRUT AS REQUIRED(TYP) 8 EXI5TING OPEN WEB STEEL J015T(TYP) BRACE 8 UN15TRUT FOR DEFLECTION. 8" BOTTOM OF EXISTING OIL VARIES BOTTOM OF EXISTING VARIES PROVIDE GAP OPEN WEB STEEL JOISTS V.I.F. BETWEEN BRACE METAL STUD TOP SLIP TRACK OPEN NEB STEEL JOISTS V.I.F. 4 UN15TRUT FOR ATTACHED TO 2x4 WITH#8 3/4 PLYWOOD PROVIDE SEISMIC BRACING PLATE DEFLECTION. SCREWS(TVP.AT EACH END) (2)1/16'#8 SHARP POINT 5CREW5 (2) 1/I6" #8 SHARP POINT 5GREW5 DRYWALL CONTINUE PLYWOOD AND METAL STUD �� 20 GA.,3 5/8"STUD BRACE FRAMING TO UNDER51DE OF EXISTING AT V-0"O.G.MAX. t,1 METAL 20 GA 3-5/8 METAL STUD DIAGONAL ALTERNATE DIRECTIONS 2015-0131 a1 STUD ROOF DECK BRACING® 48"O.G.PERPENDICULAR Job Name and Number: i TO WALL.ALTERNATE DIRECTIONS. _J AMIGO PROVIDE FIRE INSULATION A5NOTE: SECURITY REQUIRED FOR FIRE STOPPING UN15TRUT SHALL BE CONNECTED TO NOTE: Proposed EX15TIM JOISTS 16"WITHIN PANEL ATTACH BOTTOM OF BRACE TO TOP TRACK OF WALL WITH(3)#8 SHEET w MESH BOTTOM of VARIES BOTTOM of VARIES POINTS WITH PIOOO UN15TRUT METAL SCREWS EACH BRAGS. DO NOT ATTACH THROUGH CEILING TILE. VERIZON SUSPENDED 01-6. SEE PLAN SUSPENDED 61-6. SEE PLAN FASTENERS AND BOLTED 6ETWEEN z AMIGO 5ECURA CONTINUE GYPSUM BOARD AND CONTINUE ATTACH BOTTOM OF BRACE TO TOP TRACK OF WALL OPEN WEB STEEL BOLTED FLANGES AT L CLIPS INSTALLED METAL STUD FRAMING TO b"ABOVE PROVIDE(U LAYER 3/4"GDX FIRE RETARDANT GYPSUM BOARD WITH(3)#8 SHEET METAL SCREWS FOR EACH BRACE. CONTRACTOR5 P15CRETION(TYP) STUD BR GING DETAIL STORE FOLLOWING THE SUSPEND.GLC. PLYWOOD ON INSIDE SURFACE OF ALL INVENTORY AND METAL MANUFACTURERS WALLS. NO GYPSUM BOARD REQ'D,SEE PLAN (U LAYER 5/8'GYPSUM BOARD ON BOTH SIDES OF ATE: v SCALE: 11/2"=1'-0" (LEED) o RECOMMENDED STUD�FRAMING FRAMING.HOLD BOTTOM EDGE 1/4"ABOVE FINI5H FLOOR TGG-ES#FOR METAL 5TUD5.........ER-4943P ALL DIMENSIONS ARE FINISH DIMEN510N5. NON-INVENTORY SIDE TO b ABOVE SPACING FASTEN TO METAL STUDS WITH#b X 15/8"DRYWALL (STUDS SHALL BE PER"STEEL STUD PROVIDE(I)LAYER 5/8'G INVENTORY 51DE SUSPEND.GLC. SCREWS 12'O.G. IN FIELD AND 8"O.G.AT SEAMS. MANUFACTURERS ASSOCIATION') BOARD ON THI5 SIDE.HOLD TGG-ES#FOR FA5TENER5..........ER-3056 BOTTOM EDGE I/4'ABOVE FIN15H BATT INSULATION FULL HEIGHT OF PARTITION BATT INSULATION FULL HEIGHT OF PARTITION (ITYi"SHEET METAL'BUILDEX 5CREW5) M FLOOR.FASTEN TO METAL STUDS 20 GAUGE,3 5/8' METAL STUD WALL FRAMING AT Ib"O.G. 20 GAUGE,3 5/8'METAL STUD WALL FRAMING AT Ib"O.G. IGG-E5#FOR SHOT PINS..........E5R-1663 WITH#b X 15/8"DRYWALL o � _ _ _ _ _ _ _ loh Address �' 50REYG IT D.G. IN FIELD AND 4"BASE(SEE INTERIOR FINISHES 5CHEDULE) 4"BASE(5EE INTERIOR FIN15HES SCHEDULE) (.145 POWDER DRIVEN HILTI PINS) rTi Washington Square Mall CD 8'O.G.AT SEAMS. TOP OF FIN15HED FLOOR OL 0'-0" TOP OF FIN15HED FLOOR OL 0'-0' 9585 S.W. Washington 3/4'LONG HILTI CONTINUOUS TRACK W/1/4" 0,3/4'LONG HILTI ' NOTE: PROVIDE FIRE SEALANT AT CONTINUOUS TRACK W/I/4 �, Square Road F- ANY PENETRATIONS IN RATED WALLS POWDER ACTUATED ANCHORS @ 32'O.G. POWDER ACTUATED ANCHORS®32"O.G. OR 97223 Portland, Space R05-1307 U WALL UP TO STRUCTURE ABOVE W,�LL UP TO 6" ABOVE CEILING GRID CLk r` DrawingTlde: O \` >1 E I L7�j U � - Interior Elevations and FIXTURE VENDOR TO �J5�ALUMINUM COYER PLATE _ ® Construction Details SHADED AREA INDICATES N 613055-SECTION OF FIXTURE MODIFY OBSTRUCTED OMNIBOX SERIES 830CKTCAL.SET I I 0 SUPPORT LEG. AREA A5 REQUIRED FULLY RECESSED INTO TILE FLANGE z TO ACCE55 OUTLETS. ONE-GANG,ADJUSTABLE HEIGHT,BRUSHED I . ......,.., ----- 3 CRITICAL NOTE: ALUMINUM TILE FLANGE-OMNIBOX SERIES Drawn By. North a FINAL INSTALLATION OF(OVER 80TAL.ADJUST INSTALLED HEIGHT FLUSH I JL avow. cu PLATE CANNOT BE HIGHER THAN 0 0 W/FIN15HED FLOOR �' checked By, KG FINISH FLOORING. 5'-3"TO ADJACENT FLOOR BOX GROUPING 0 0 0 WOOD FLOORING TO BE 50RIBED SMOOTH LINE OF 14 GA.CENTER MOUNT (SEE PLAN FOR ACTUAL DIRECTIOW I ALIGN TOP OF PLATE AND TILE -- - - Date Issued For A EXI5TIN6 WALL ABOVE EX15TING AND STRAIGHT AROUND PERIMETER OF ANCHOR BRACKET ABOVE.BY I Tient: 12/24/15 � FLANGE FLUSH WITH TOP OF ROUTE CONDUIT A5 REQUIRED __ DOOR OPENING TILE FLANGE.FILL ANY GAPS WITH CLEAR MILLYVORK VENDOR G.G.TO WOOD FLOORING 4 4 INTO FLOOR BOX I EP i Landlord: 12/24/15 EXISTING 56PENDEP GEILING SILICONE CAULK iF- PLACE NO CONDUIT RUNS ONE-GANG BRUSHED ALUMINUM TILE I I (� I� � Permit: 12/24/15 _J BOTTOM OF VARIES EXISTING FLOOR SLAB � UNDER ANCHOR BRACKET FLANGE-OMNIBOX SERIES 818TAL i I Bid: LI D G G. SEE PLAN L, " ONE-GANG CAST IRON FLOOR BOX I o®o11 I Construction: " �I MIN. -OMNIBOX 880051-I I I Revision Issue: 7-04 GONTINUOU5 3 5/8 METAL TRACK �— I ir�0�" /a�,� No. Date Description 1 3 � I - a , BRUSHED ALUMINUM COVER PLATE - J I \ Ll 210 ALIGN FINISH I) LAYER 5/8'GYPSUM BOARD ON 60TH 4° i% 4" d' m o OMNIBOX 830GKTGAL I 1 �� 0 (BOTH SIDES) SIDES OF FRAMING.HOLD BOTTOM EDGE I/4' m � o o o ABOVE FIN15H FLOOR.FASTEN TO METAL LD STUDS WITH#b X 15/8"DRYWALL 50REW5 10 I I 4 12"O.G. IN FIELD AND 8'O.G.AT SEAMS. ° ° GENTERLINE OF FIXTURE LEG AND V) z FLOOR BOX GROUPING 3 OUTLINE OF FIXTURE ABOVE. I " ROUTE CONDUIT POWER DATA FOR RETRO-FIT,SAW CUT EXISTING W 20 GAUGE,3 5/8 METAL 5TUD WALL CONCRETE AS REQUIRED TO SET LONE-GANG CAST IRON FLOOR BOX-OMNIBOX FOR RETRO-FIT,FILL WITH ARDEX TRM OUTLINE OF 1.125"x 2.5"CLEAR I �'' ' `� e I C) FRAMING AT Ib O.G. NEW FLOOR BOX AND RE-ROUTE SERIES 880651-I.SET BOX PARALLEL AND TRUE (OR OTHER FAST SETTING CONCRETE REQUIRED CONCRETE ANCHORS LAYOUT POINT OF OPEN AREA WITHIN FIXTURE ABOVE L01 INTO FLOOR BOX I Q I 0 4"BASE(5EE INTERIOR FINISHES SCHEDULE) CONDUIT INTO FLOOR BOX. TO CENTERLINE OF FIXTURE SUPPORT PANEL. PATCH MATERIAL) BY MILLWORK VENDOR. FLOOR BOX GROUPING. FOR POWER CORD AND DATA N QSET BOX ELEVATION SUCH THAT THE INSTALLED FOR NEW INSTALLATION,FILL TRENCH AS SEE FURNITURE PLAN GABLE CONNECTION. TOP OF FIN15HED FLOOR �0'-0" ELECTRICAL CONDUIT-POWE TILE FLANGE,IN FULLY RECESSED P05ITION, 15 INDICATED ON DEMOLITION PLAN. 0 3 ORDATA.RE-ROUTE A5 W 1/4'BENEATH THE FIN15H FLOOR ELEVATION.Q CONTINUOUS TRACK W/ 1/4" 0,3/4'LONG HILTI REQUIRED INTO FLOOR BOX o w POWDER ACTUATED ANCHORS @ 32"O.G. J 3 Z DOOR OPENING INFILL TYPIGL FLUSH MOUNTED POWER DT,� SECTION DETAIL TYPIGR �ILI�IHM�01N�TED POWER DT PLAN DET, IL Drawing Number: x SCALE: 3/4"=i'-0" 3"=1'-0 — - �CO CO - --- - Z Qf� KEY PLAN N� � SCALE: i/8"=1'-0" C:, CU 10 OF 31 CABINET FINISHED END(L-5) 3'-0" 2'-0° 3'-0" 1'-3" FILLER(L-5) 1-6 u 2'-6° 2'-0' 125° FULL OVERLAY 'BLUM' (L-5)FIN15H 12 3/4' 1'0" I I L-5 FIN15H ON 51DE 1, 13 1/2" i= CONGEALED SELF-CLOSING (L-5)ON ALL GRUSKIN 1q rn CLEARANCE FOR UPPER CABINETS(L-5 FINISH) UPPER CABINETS(L-5 FINISH) : HINGES,(2)PER DOOR;(3)ON EXTERIOR EXP05ED DESIGN. CABINET DOOR, L-5 FIN15H ON DESKTOP COPIER / / / DOORS OVER 36". SURFACES OF • C. TYP 9F(2) SIDE(TVP) _ = 4 4 = / ICN CABINETS 125° FULL OVERLAY z 3/4"THICK DODR CABINET BOX 294 Morris Avenue S ringfield,N 07081 cn cn O ' O Tel: 973.376.4411 Fax: 973.376.8989 (L-5 FINISH) I I I LINE OF DESKTOP COPIER ------; = DATA OUTLET,SEE - _ ABOVE AND BELOW GLUM CONGEALED I c' I I SELF-GLo51NG HINGES, > 3/4'ADJUSTABLE WHITE www.GruskinGroup.com NJ REG 0100.9869-I+ / \ ELECTRICAL PLAN(TYP) _ i GFI OUTLET ON WALL : : NE SH —PRE-DRILLED HOLES ` (2)PER DOOR � MELAMINE ELVES; - ---- CONTINUOUS PLUGMOLD I I/2 °THICK;25'DEEP (TVP.OF 2) ,L (2)AT 3'-0' HIGH CABINET (TYP-) This document and the Ideas and designs Incorporated I I/2 THICK,25 DEEP 4 LAMINATE TOP WITH 4'HIGH 4 3/4'THICK DOOR ,moi " herein, as an Instrument of professional service,is the EMPLOYEE LOCKERS �• , WITH OUTLETS @ b O.G. ry H, (3)AT 3-10 HIGH CABINET �? (2)3/4"ADJUSTABLE \ LAMINATE TOP WITH 4 HIGH - property of GRUSKIN ARCHITECTURE+DESIGN,P.C.,and Q I I ON BAGK5PLA5H BAGK5PLA5H(L-5 FINISH) REFRIGERATOR BY PRE-DRILLED HOLES(TYP.) o m Is not to be used in whole or in part for any other project 4'BRUSH CHROME BACK SPLASH(L-5)W/(2) _ _ WHITE MELAMINE GROMMET / / ERGONOMIC KEYBOARD 24'DEEP BASE CABINETS -- - GENERAL CONTRACTOR cn n, without the enau SIGN, zatlon of GRUSHIN WIRE PULL(TYP) \ / I I I (2)3/4 ADJUSTABLE WHITE PRE-DRILLED HOLES(TVP.) SHELVES ARCHITECTURE+DESIGN,P.C. i� / - OPEN \/O/P EN TRAY BY CABINET (L-5 FINISH),TYP. MELAMINE SHELVES " All Rights Reserved \ I I I PROVIDE WG-I FROM TOP �+ cv OPEN m " 3/4 THICK BACK t J iCONTRACTOR(TVP) / \ 3/4 THICK BACK ' 11 1 1 11 11 It OF BAGKSPLASH TO / WALL BASE ' 3/4 THICK BACK f— ©2015 Gruskin Architecture+Design,P.C. UNDERSIDE OF GABINET Kenneth A. Gruskin AIA WALL BASE 2 0, 3'0' 3'-0" 3'-0" 2'-0" 3'-0" 1'-3" 2„ WALL BASE 1'-6" 2'-b" 2'-0" 2'-9" LIGHT BULB STORAGE 13/4" FILLER(L-5) MIN. 4'BRUSHED CHROME WIRE 4"BRUSHED CHROME WIRE PULL AL 5421 MT 2537 FILLER(L-5) q 10 24"DEEP BASE CABINETS 11 12 8 LOCK(IF APPLICABLE)FULL AK 131 1 NC 9961 AR 3811 ND 1666 (L-5 FINISH),TVP. UPPER CABINET UPPER CABINET SECTION- CA 3929 NE 2796 OPEN OFFICE ELEVATION LOCKERS P�E LEVATION NOTE: CA 9613 8 NH 0041CO ARC-400347 NJ AI 09999 UPPER SHELF SECTION-TECH CT 9613 NM 004168 CABINETS WITHIN BREAK AREA �j DC ARC100723 NV 5521 SHALL HAVE NO LOCKS,NO OPENING SCALE: 1/4" = 1'-0" ✓ SCALE: 3/4" = 1'-O" SCALE: 3/4" = 1'-O" 56ALE: 3/4" = 1'-0" DE 0006261 NY 025528-1 NY IN BACK OF BASE CABINET AND FL AR91629 OK 04895 5-1/2'HIGH DRAWER5,TYP. NOTE: INTERIOR OF CABINET BOX SHALL BE WHITE MELAMINE. GA RA011075 OH 13761 HI AR 11489 OR 4899 IA 05713 PA RA-015432—B ID AR-984459 PR 19965 INTERIOR ELEVATION IL 001-019152 RI 2666 � IN AR10400066 SC 6834 KS 4674 SD 11532 MILLWORK NOTES: KY 5734 TN 101374 3/4"THICK,4"HIGH LA 5734 TX 17680 3/4'THICK,4"HIGH 3/4"THICK,4'HIGH GONTINUOU5 PLUGMOLD BACK5PLA5H ME ARC 2596 UT 5881358-0301 3/4'THICK,4"HIGH I'° I. ALL CABINETS AND DRAWERS SHALL HAVE SILENCERS, MD 11016 Vf 2572 $AGKSPLASH BAGKSPL ASH WITH OUTLETS® b"O.G. WHITE MA 10635 VA 0401 011223 B�K'P- ` 5EE ELEVATION FOR I I/2'LAMINATE TOP MINIMUM(2)PER DOOR OR DRAWER. MI 1301052379 WA 10344 I I/2'LAMINATE TOP 25" I I/2"LAMINATE TOP 31 25" MELAMINE 1 1/2'LAMINATE TOP 25" LOCATION(WIREMOLD 3/4"HINGED PANEL 25 MN 44326 WI 9900-005 4"BRUSHED CHROME 2. ALL CABINET DOOR5 AND DRAWER5 FOR TECH AND On MO A-2005029740 WV 3727 125°FULL OVERLAY N 125° FULL OVERLAY - 2000 SERIES WIRE PULL IN OPEN OFFICE SHALL BE EQUIPPED WITH SELF-LOCKING MS 3860 WY C-1967 #ENGTH S GRAY- LOCK(CHROME) CABINET LOGK5. ALL GABINET5 SHALL BE KEYED ALIKE, Professional Seal: 'BLUM'CONGEALED 'BLUM'CONGEALED `Y LENGTH 60 REQUIRED- . SELF-CLOSING HINGES, SELF-GL0511�HINGES, SEE ELEVATION) EXCEPT FOR LOCKERS. ALL LOCKERS SHALL BE KEYED (2)PER DOOR �, (2)PER DOOR = SINK-2 125°FULL OVERLAY CABINET CONTRACTOR SEPARATELY AND HAVE(U MASTER KEY. SHALL PROVIDE 18" SUPPORT G� IENALEjH CONCEALED �, 3. CABINET CONTRACTOR SHALL PROVIDE OPENING IN DRAWER WITH METAL DRAWER WITH METAL-/ HIGH X 24'WIDE CLIPS (3)PER DOOR ' GLIDES GLIDES : R WITH METAL - OPENING IN BACK OF (TYP OF 4) ZWHITE BACK OF BASE CABINETS(WHERE 5HOWN)A5 REQUIRED Q!) 4'BRUSHED CHROME 0 4'BRUSHED CHROME 6LIDE5 0_1 _ BASE CABINET AS - 2 � � :MELAMINE • FOR POWER,EXCEPT BREAK AREA SHALL HAVE NO 4'BRUSHED CHROME REQUIRED FOR ACCESS o Z 3/4'THICK FIXED SHELF OPENING IN BACK OF BASE CABINET. WIRE PULL N WIRE PULL o , z ETH.A.GRUSKIN ADJU5TABLE 5HELVE5 ADJUSTABLE SHELVES �, WIRE PULL TO TELEPHONE/DATA tu (WHITE MELAMINE) 4. CABINETS WITHIN BREAK AREA SHALL HAVE NO LOCKS, (WHITE MELAMINE) (WHITE MELAMINE) ADJUSTABLE SHELVES AND POWER OUTLETS z / p. 4599 3/4'THICK DOOR WITH 3/4'THICK DOOR WITH : (WHITE MELAMINE) BELOW COUNTER. = z NO OPENING IN BACK OF BASE CABINET AND 5-I/2"HIGH 3/4'THICK DOOR WITH : (WHERE REQUIRED)SEE ----- Y ,� DRAWERS,TYP. SPRINGFIELD,NJ z 3/4 THICK DOOR WITH LO K,5EE NOTES LO K,SEE NOTES �' L K,5EE NOTES - _ u, � INDIVIDUAL LOCK � 3 � 5. SELF-LOCKING CABINET LOCKS SHALL BE KENSTAN SNAP / 125° FULL OVERLAY BOLT LOCK WITH INTERCHANGEABLE GORE, � ' PRE-DRILLED HOLES-/ PRE-DRILLED HOLES FULL EXTENSION HEAVY . Consultant: 3" 3" DRILLED HOLES-J GLUM CONGEALED DRAWER GLIDES 311 VALANCE PANEL 3" 14" I (MODEL DL- I-36 -RV-(BG)BRUSHED CHROME FINISH (TYP.) (TYP.) 3„ SELF-61HINGES. DUTY UNDER MOUNT MTL. 24" 8"MIN 4"VINYL BASE -N) KEYED ALIKE. 4'WALL BASE 24 4"WALL BASE ( ) 24' (2)PER DOOR KNEE GLEARANGE SIZE A5 REQUIRED, 18" KEN5TAN LOCK COMPANY 4'WALL BASE 4'WALL BASE (L-5 FINISH) 101 COMMERLIAL STREET,SUITE 100 PLAINVIEW,NY II803 BASE CABINET SECTION BASE G BINET SECTION BASE G>�BINET SECTION-TECH RECYCLE CENTER CABINET SECTION SINK GLE�RANCES-BREAK ARES BULB STORAGE SECTION (516)516-9090. 8 5GALE: 3/4" = 1'-0" 5GALE: 3/4" = 1'-0" O SCALE: 3/4" = 1'-0" 11 5GALE: 3/4" = 1'-0" 5GALE: 3/4" = 1'-0" 5GALE: 3/4" = 1'-0" b. ALL GROMMETS SHALL BE CENTERED ABOVE OUTLET BELOW. 1. ALL GROMMETS SHALL BE 2" �AND "PUTTY" IN COLOR i 8. CONTRACTOR SHALL COMPLETE THE VOG SUBMITTAL 2 3/4" / FORM AND PROVIDE MATERIAL SAFETY DATA 5HEET5 (U l Job Name and Number. (U (M5D5)HIGHLIGHTING THE VOG CONTENT FOR ALL 2015'0131 l 2'O GROMMET ADHE51VE PRODUCTS. A COPY OF THE FORM GAN BE _J 21-0 3/4' 2-OM 3/4° 1'-I0 I/8' 1/ ! L/4„ FOUND ON THE LEEP PROTOTYPE GREEN SPECIFICATIONS. Proposed 3/4" 3/4" 10 15/16' 3/kk 4 IO 13/16" SCREW FIXTURE DIRECTLY I. CONTRACTOR SHALL COMPLETE THE "MATERIAL V E R I ZO N W I'-10 I/2° INTO STUDS THROUGH THE SUBMITTAL FORM'- WOOD PRODUCTS FOR ALL WOOD m BACK OF THE FIXTURE PRODUCTS. A COPY OF THE FORM CAN BE FOUND ON STORE z THE w 4' J (3)3/4"THICK ADJUSTABLE `r D TO GREEN SPEGIFIGATIONS. cJ m m SHELVES(WHITE MELAMINE)AND (b)3/4"THICK ADJUSTABLE 10. CONTRACTOR SHALL PROVIDE GUT SHEETS OF THE (LEED) oDRAWER (3)PERFORATED ADJJSTABLE SHELVES(WHITE MELAMINE) DOCUMENTATION FOR EACH WDOD PRODUCT A o 5HELVE5 (6)3/4'THICK ADJU5TABLE HIGHLIGHTING RECYCLED CONTENT INFORMATION. 4 SHELVES(WHITE MELAMINE) W v DIVIDER WHITE MELAMINE 3/4"THICK DOOR WITH PRE-DRILLED HOLE5(TYP) TVP. �7���M�ETDETAIL INDIVIDUAL LOCK(L-5 FINISH) - Job Address: - - — - - - I-0 I 0 WHITE MELAMINE WHITE MELAMINE Washington Square Mall a5GALE: 1 1 n u 7 !, 4'BRUSHED CHROME o o JL TIMBERLINE LOCK 290 KEY# IOOTA W —�.\ 9585 S.W. Washington N WIRE PULL(TYP) Square Road W I Portland, OR 97223 z TABLET CHARGING CABINET � 1250 SELF-CLOSING 13JR0 HINGE � 1� DETAIL PL,�N SECTION Space R05-R07 A TABLET CHARGING ; 21 2'-0' 5GALE: 3/4" = 1'-0" l z CABINET WITH(b) 3/4'THICK DOOR WITH l DrawingTlde: ADJU5TABLE 5HELVE5 : INDIVIDUAL LOCK(L-5 FINISH) PROVIDE PERFORATED PROVIDE PERFORATED ® PANEL ON TOP PORTION PANEL AT TOP PORTION ou° ,? BLOCKING A5 REQUIRED 4"HIGH WALL BASE(B-3) I ' o OF CABINET DOOR OF CABINET DOOR 0 Millwork Elevations n 04 i., SCREW FIXTURE DIRECTLY CR055 BRACING SUPPORT; _ TM EHT H, e, [} ® and Details 4'BRUSH CHROME WIRE a' ADJUST SPACING AS REQUIRED m I I 3 INTO STUDS THROUGH THE 2 PULL(TVP.) - BACK OF THE FIXTURE ❑ a e oa o°o° GDX PLYWOOD BASE ----- o` a 3 (3)UPPER WHITE a� Q U 7. PERFORATED 2'-0" 3/4" 21-0' I' _ __ 1 Drawn BY JL a°°"` ADJUSTABLE SHELVES I -= _ Checked By. o TIMBERLINE LOOK _ 16 : 125° SELF-CLOSING POSTER CABINET POSTER CABINET I �`` KG 290 KEYS IOOTA N EURO HINGE DETAI��� > SECTIONI I o � DatelssuClior ent: 12/24/15 a (2)CABINET DOOR '� 1 ® ® e Landlord: 12/24/15 WITH L-5 FINISH =_ -/_ WHITE MELAMINE 5GALE: 3/45GALE: 3/4" = 1'-O" 1 I 1 E I � L-5 FINISH ON 510E � PRE-DRILLED 1 I � I Permit: 12/24/15 J (TYP.) HOLES(TYP) i I I Bid: TIMBERLINE LOCK I °®° I Construction: W 4'HIGH WALL BASE : 290 KEY#IOOTA I ✓i I Recision Issue: (B-3) 2'-0' u� p /,j — I No. Date Description M 4 (3)LOWER 3/4 THICK 21-011 I I e-? AD15TABLE 5HELVE5 WITH �W' z T>�BLET CH,�RGING GBINET WHITE MELAMINE FINISH 3/4' 3/4' (4), 18'DEEP,3/4'THICK � 1 m 3/4"THICK DOOR WITH 101/8 101/8 ADJUSTABLE WHITE MELAMINE I I LD SCALE: 1/2" = 1'-0" ' SHELVES ON WHITE HEAVY-DUTY INDIVIDUAL LOCK(L-5 FINISH) (SHELVES(MITE MELAMINE) - a OPENING FOR POWER DOUBLE-TRACK STANDARDS. 3 ACCE55 OPEN AREA FOR STORAGE FASTEN ALL SHELVES TO SELF OF TALL ITEMS - SUPPORT BRACKET Al.WOOD00 • eri.: SCREWS @EACH SUPPORT I 4' HIGH WALL BASE(B-3) o _ J eese i i I 4 — pari °: LOCATION(TYP) - - - v °°°° €€ �i�ir��� oeeeee��e°ee oo; : I €ir o CD PA55-THROUGH r = r�lee eesili33aa:�:?'i'oe23e SELF SUPPORT BRACKET I > < (U - Q so�oo �.i- E r I ACCESS FOR WIRE - �� ��f€� iiTYP Z m =o�Se °seep°e`III'�lE� 'EEEee�eeE�seli., . o MANAGEMENT 3/4 THICK DOOR WITH „3 _ � ..�i�osoao°epoeo€� `°`�`� I I W Q INDIVIDUAL LOCK(L-5 FINISH) eDeEee 'I: :;;ir,:e o 000:,:;;:�;:; esipiieri: 4'-0"HIGH PEG BOARD ALL GDX PLYYVOOD BASE 000 or'eiiiiii r '• I°iri`iiiie,ii r;:.:; o TIMBERLINE LOCK 290 KEYS •i _ AROUND SHELVING AREA AND 0 3" 1'-11/4" II 1/8" IOOTA PROVIDE FURRING CHANNEL w J 3/4" 2,0„ 1" 4'BRUSHED CHROME 77/ BACKING AS REQUIRED X WIRE PULL(TYP) TRACK BEHIND PEG BOARD, VINYL BASE -_ Drawing Number. X 0" TABLET CHARGING CABINET POSTER CABINET _LLL I -- - - -- NM DETIL SECTION DET>�IL PL>�N SECTION TYPIG ��HEL /IN5 ELEVATION KEY PL>�N ..r. = W o W l >to !o N 11 OF 31 STANDARD INTERIOR E I N I SHE5 PAINT GOLOR5 DOOR 56HEDULE BENJAMIN MOORE REGAL SELECT#2134-20 "MIDSUMMER DOOR FRAME HARDWARE SYMBOL ITEM MANUFACTURER SPECIFIGATION AND COLOR P_6 NIGHT',DOLOR PREVIEW EGGSHELL FINISH ON FIXTURES, MILLWORK,DOOR5 E FRAMES. v ~ LOCATION: LIFESTYLE WALL PILASTER,HOME SOLUTIONS DOOR O o o Q '� o z Q VINYL SHEET ARM5TRON6 ARMSTRONG MEDINTONE WAINSCOT,VERIZON SERVICES WALL PANEL t ? `� � O O Q GRUSKIN VSF-I FLOORING COLOR: "ROCK DUST MID",H6308 N0. ROOM NUMBER NAME SIZE SWING STYLE MATERIAL FINISH MATERIAL FINISH RATING LOGKSET ,� �, LU �, o GOMMENT5 P-� BENJAMIN MOORE REGAL SELECT#PM-4 "BRILLIANT WHITE', Oj 101 RETAIL 5ALE5 (2)3'-0"x q'-0" PAIR BB GLASS CLEAR NONE NONE NONE WA NO YES* NO NO YES NO A;1/2"THICK CLEAR TEMPERED FRAMELE55 6LA65 DOORS WITH 10"HIGH BOTTOM RAIL. COLOR PREVIEW;E665HELL ON WALL5,SEMI-GLO55 ON PROVIDE KEY LOCK AT BOTTOM RAIL ARCHITECTLJRE + DESIGN.PC. CARPET TILE NUMBER: R241X DOORS AND FRAMES. ,G,D; WITH IS"x 18"ONE-WAY GLA-%VISION PANEL ONE WAY ON RETAIL SIDE THI5 DOOR 15 A MEANS OF CARPET TILE PATGRAFT(WWW.PATGRAFT.GOM) 0 102 OPEN OFFICE 3'-O"x l'-0"x 13/4" RH GG WOOD SOLID GORE d GLA55 *P-6/1'-01 PAINT H.M.H "P-6/P-q PAINT NONE PASSAGE YES YE5 YES NO YES YES E6REe.�S PASSAGE LOGKSET SHALL BE USED AND CARD ACCESS SHALL BE INSTALLED MD ELECTRIC STRIKE). 294 Morris Avenue Springfield,NJ 07081 G-I FLOORING CONTACT: JJ TERZ16NI (614)582-8131 SIZE: 24'X 24° LOCATION: CEILINGS d SALES AREA WALLS CONTRACTOR SHALL INSTALL A PROXIMITY READER AND DOOR CHIME TO SIGNAL WHEN DOOR 15 OPENED Tel: .Grusk 6.441 I Fax: 973.376.8989 989 JO5EPH.TERZI6NI@PATCRAFT.COM INSTALLATION: A5HLAR BENJAMIN MOORE REGAL SELECT#PM-q "BLACK', WITHOUT GARD KEY.*PAINT P-6 ON RETAIL SALES SIDE AND PAINT P-q ON OPEN OFFICE SIDE. www.GruskinGroup.com NJ REG 0100 9869-14 PORCELAIN TILE CASALGRANDE PADANA PORCELAIN TILE P_g COLOR PREVIEW;EGGSHELL ON WALL5,SEMI-GLO55 03 106 INVENTORY Y-O'x T-0'x 13/4' LH AA STEEL INSULATED P11 PAINT H.M. P-q PAINT NONE ENTRY-2 YES YES YES YES YE-5 YES A,G,Dg This document and the Ideas and designs Incorporated PT-6 WWW.GA5ALGRANDEPADANA.GOM SERIES: 5PAZIO ON DOORS AND FRAMES. herein, as an Instrument of professional service,Is the COLOR: GRIGIO LOCATION: SALES AREA BRAND FOCAL WALL ® 106 INVENTORY Y-6"x W-0' 66** GALVANIZED STEEL WA WA WA NONE WA WA WA WA WA WA WA "ROLLING SECURITY 6RILLE MOUNTED ON BACK AREA 51DE OF INVENTORY DOOR SEE NOTE BELOW property of GRUSKIN ARCHITECTURE+DESIGN,P.C.,and CONTACT: PRO SPEC A>✓p;DOOR TO BE UNDERCUT I"TO ALLOW FOR AIR TRANSFER PROVIDE Ib' Ib'LOUVERED OPENING ON Is not to be used In whole or in part for any other project BRIAN KELLEY(114)665-0654 EXT: 301 FINISH: NATURAL BENJAMIN MOORE REGAL SELECT#AF-685'THUNDER", 05 104 ELECTRICAL ROOM 5-0"x T-O'x 13/4' LH AA WOOD 50LID GORE P-1 PAINT H.M. P-01 PAINT NONE ENTRY-1 YES YES YES NO NO NO BOTTOM PORTION OF THE DOOR without the written authorization of GRUSKIN BKELLEY®PR05PEGLLCLOM 51ZE: 12X24 AFFINITY. ARCHITECTURE+DESIGN,P.C. ADD BONDING PRIMER FOR METAL #55VRZ$POS © 105 MANAGER 5-0'x T-0'x 13/4' LH HH WOOD SOLID GORE d GLASS P-q PAINT H.M. P-q PAINT NONE ENTRY-1 YES NO NO NO NO NO A,G,D;WITH IS'x 18'CLEAR GLA55 V151ON PANEL All Rights Reserved GROUT: I/8"KERAPDXY 21 SILVER E66WIL ON WALL5,SEMI-01_055 ON DOOR5 AND FRAMES. A G,D;DOOR TO BE UNDERCUT I"TO ALLOW FOR AIR TRANSFER. PROVIDE HAT AND GOAT HOOK5 ©2015 Gruskin Architecture+Design,P.C. LOCATION: BACK OF HOUSE WALL,DOORS d FRAMES O 101 WOMENS RESTROOM 3'-O°x 1'-0"x 13/4' LH AA WOOD SOLID GORE Pa PAINT H.M. P-q PAINT NONE PRIVACY YES YES YES NO NO 114 AND SINGLE ROBE HOOK. SEE NOTE BELOW ACROVYN IMPACT SPECIALTIES AGROVYN BY IMPACT SPECIALTIES 108 MENS RESTROOM 3'-0"x'I'-0"x 13/4' RH AA WOOD SOLID GORE P-9 PAINT H.M. -q PAINT NONE PRIVACY YES YES YES NO NO P14 C A G,P,DOOR TO BE UNDERCUT I'TO ALLOW FOR AIR TRANSFER. PROVIDE HAT AND COAT HOOK5 Kenneth A. Gruskin AIA 888-424-6 p281 COLOR: OYSTER GRAY FAINT NT NOTES OS AND 51W ROBE HOOK. SEE NOTE BELOW AL 131 MT 2537 FAX 0108-84q-4215 TEXTURE: SUEDE Q 109 TELCO 3'-0"x l'-0"x 13/4" RH AA WOOD SOLID GORE P-q PAINT H.M. P-q PAINT NONE ENTRY-2 YES YES YES YES YE5 YES A,G,D;PROVIDE DOOR SY�EP. SEE SPECIFICATIONS BELOW AK 13167 NC 9961 WG-1 GEORDER5®G-56ROUP.GOM THICKNESS: .040 THIGKNE55 TYPICAL APPLICATION AND INSTALLATION AB9;PROVIDE DOOR VIEWER,5ECURITY HIN6E5 8 PICK GUARD. "PAINT INTERIOR 51DE ONLY. DOOR SHALL AR 3811 ND 1666 SHEET 51ZE: 4'-0"X V-0" 10 102 OPEN OFFICE Y-0'x T-0'EXISTING N.1.FJ LH AA STEEL INSULATED P-q PAINT" H.M. P--q PAINT" NONE PANIC-2 NO YES YES YES YES YES HAVE PANIC,BAR HARDWARE. SEE NOTE BELOW. CONTRACTOR SHALL PROVIDE HINGES WHICH WILL NOT ALLOW AZ 39209 NE A-3547 ALL TRIMS,INCLUDING INSIDE,VERTICAL AND WAIN500T TRIM SHALL WALLS: LO SHEEN EGGSHELL LATEX REMOVAL OF HINGE PINS Vim!DDDR 15 IN LOCKED POSITION. STEEL PINS SHALL BE SET IN DOOR WHICH ENGAGE CA C-29898 NH 2796 09999 BE ORDERED IN 10'-0"LENGTHS;COLOR: OYSTER GRAY DOORS AND FRAMES: SEMI GLOSS,ALKYD(EXCEPT AT P-b) FRAME N­IEN DOOR 15 CLOSED. CO 9613 ARC-400347 NJ AI NM 004116868 PROVIDE 55M20 HEAVY-DUTY CORNER GUARDS ON ALL EXPOSED FIXTURES AND MILLWORK: SEMI 6LO55 ALKYD(EXCEPT AT P-6ARC1 DC ARC100723) CT COMMENT KEY LOCKET KEY DOOR 5TYLE KEY � DOOR 56HEDULE NOTES 00723 NV 5521 OUTSIDE GARNERS;COLOR: OYSTER GRAY CEILING: MATTE LATEX MODEL NUMBER DE 0006261 NY 025528-1 NY SLATWALL: LO SHEEN EC65HELL ALKYD AA FLUSH DOOR 'EXISTING' FL AR91629 OK a4895 A LOCK5ET SHALL BE OPERATED ENTRY =FRONT DOOR CYLINDER PASSAGE LATCH N0105 DOORS NOTED A5 EXISTING SHALL HAVE HARDWARE MODIFIED A5 CLOSERS SHALL BE NORTON SERIES 1600 REGULAR ARM BY NORTON GA RA011075 OH 13761 A(ROVYN CORNER GUARD(2'LEGS) FROM THE INTERIOR SIDE WITHOUT BB ALUMINUM AND 6LA55 ENTRY DOOR REQUIRED TO MATCH SPECIFICATIONS INDICATED ON DOOR SCHEDULE. DOOR CONTROLS(600)438-1162,OR APPROVED EQUAL. ALL HI AR 11489 OR 4899 MODEL-55M-20 ATTACHED USING MOUNTING HARDWARE PROVIDED ALL NET APPLIED PRODUCTS 5UCH A5 PAINT COATINGS PRIMERS ANY SPECIAL KNOINLEDGE, ENTRY-1 =LOCKED;KEYED WITH THUMBTURN PRIVACY LOCK ND405 ' ON INTERIOR SIDE GG FLUSH DOOR WITH IS"XIS"ONE-WAY FINISHES TO BE IN ALUMINUM NORTON FINISH SYMBOL "AL'. IA 05713 PA RA-015432-B COLOR-#01201 OYSTER GRAY LENGTH-4'-0' SEALERS,CLEAR WOOD FINISHE5 AND 5HELLA05 SHALL MEET THE VOG EFFORT OR KEY. �-I ND53xx ID AR-984459 PR 19965 GLASS VISION PANEL.PROVIDE 11"X 11' DOORS AND THEIR FRAMES SHALL BE PAINTED TO MATCH ADJACENT CONTRACTOR SHALL COORDINATE THE FABRICATION AND IL 001-019152 RI 2666 LIMITS SPECIFIED UNDER THE VOG LIMITS CHART.SEE CHART ON THIS ENTRY-2=FIXED;ENTRY BY KEY ONLY-ND ENTRY-2 NDBOxx B EXISTING DOOR �Bj>�ON INTERIOR SIDE MIRRO-PANE TEMPERED GLASS TO FIT WALL FINISH ON BOTH SIDES,UNLESS OTHERWISE NOTED. INSTALLATION OF ALL DOORS AND METAL FRAMES TO ACCOMMODATE IN AR10400066 SC 6834 RUBBER WALL BASE JOHN50NITE MILLWORK RESILIENT WALL BASE-MANDALAY MW-41-H WALL BASE;A SHEET GONTAGT: LAURIE BAATZ (440)313-8238 RECTANGULAR SHAPED PROFILE W/45'CHAMFER TOP. G HARDWARE SHALL BE STANDARD PA55A6E=NON-LOCKING 18"XIS'VISION PANEL,OR APPROVED xx:RD-FULL SIZE GORE STANDARD DOOR CLOSERS. KS 4674 SD 11532 EQUAL. .1D-TO ORDER LOCK LESS GORE • KEY ALL EXTERIOR DOERS ALIKE WITH ONE MASTER KEY. KY 5967 TN 101374 CYLINB-I LAURIE.BAATZ®JOHN50NITE.GOM COLOR: 41 BROWN;51ZE 3/8"THICK X 41/2';FIRE RESISTANCE: A5TM GYPSUM BOARD: LEVER HANDLES LATCH TYPE WITH PRIVACY-LOCKED,NO KEY PICK GUARD SHALL BE SPECIFIED BY VERIZON WIRELESS PROJECT LA 5734 TX 17680 LEVER HANDLES GD-SMALL REMOVABLE GORE ME ARC 2596 UT 5881358-0301 E648/NFPA 253(CRITICAL RADIANT FLUX) -CLA55 I,A5TM E84/NFPA GYPSUM BOARD RECEIVING LATEX PAINT SHALL BE PRIMED WITH 66 SECURITY ROLLING GRILLE FOR INVENTORY KEY ALL INTERIOR DOOR5 SEPARATELY WITH ONE MASTER KEY. MANAGER. MD 11016 Vr 2572 PANIC I =PROVIDED BY MSE CORPORATE SECURITY BD-TO ORDER LOCK LE55 GORE 255 FLAME/SMOKE-GLA55 A/LE55 THAT 450 SMOKE. ONE(U GOAT OF VINYL PLASTIC SEALER PRIOR TO RECEIVING D ALL FRAMES SHALL BE SHOP ROOM MA 10635 VA 0401 011223 TWO(2)COATS OF PAINT. PRIMED AND FIELD FIN15HED WITH FOR ENTRY DOORS(RETAIL SALES) ENTRY-I AND ENTRY-2 LOGK5ET5 SHALL HAVE REMOVABLE GORES. KICKPLATE5 SHALL BE#1905, 12"HIGH X 2'-10"WIDE(VERIFY WITH MI 1301052379 WA 10344 5TAINLE55 STEEL ELITE XPRE5510N5 MX 50LID STAINLESS STEEL WALL BASE-5TRAIGHT 5EM16LO55 ENAMEL. PANIC 2 =PROVIDED BY MSE CORPORATE SECURITY HH FLUSH DOOR WITH 18"X 18"CLEAR 6LA55 MN 44326 WI 9900-005 B-2 D WALL BASE CONTACT: (361)106-0863 COLOR: 22 GAUGE STAINLE55 STEEL#4 SATIN POL15H FOR EXIT DOOR(OPEN OFFICE) V15ION PANEL DOOR SIZE)ALUMINIUM BY HALER GOMPANIE5(800)325-01g95,OR MO A-2005029740 WV 3727 WOOD TRIM: E HEATHER-STRIPPED DOORS WITH CLO5ER5 SHALL HAVE CLOSERS MOUNTED ON THE APPROVED EQUAL. MS 3860 WY C-1967 WWW.ELITE-XPRE5510N5.GOM SIZE: 4"HIGH CHAIR RAIL PRODUCT 15 THE STRAIGHT NAL BASE NO CWOOD TRIM RECEIVING ALKYD OR ENAMEL PAINT SHALL BEOVE INCLUDED PRIMED WITH ONE(I)GOAT OF ENAMEL UNDERWATER PRIOR TO PRIVATE SIDE OF THE DOOR. Professional Seal; • PROVIDE DOOR 5WEEP FOR TELCO ROOM DOOR DOOR 51NEEP SHALL VINYL WALL BASE JOHN50NITE VINYL GAVE BASE#55 RECEIVING TWO(2)COATS OF PAINT.PAINT ALL WIRE5,RETURN I LOCK5ET5 SHALL BE 5GHLAGE D 5ERIE5 RHODES(LEVER HANDLE) BE PEMKO #2g3I00GNB CLEAR ANODIZED ALUMINUM WITH GRAY NYLON CONTACT: LAURIE BAATZ (440) 313-8238 COLOR: 121 'CEMENT' AIR GRILLE5 AND SUPPLY AIR GRILLES TO MATCH ADJACENT WITH REMOVABLE GORES. FINISH SHALL BE#626 "SATIN CHROME BRU5H INSERT BY PEMKO MANUFACTURING,(800)283-9988;,OR B-3 LAURIE.BAATZ@JOHN50NITE.GOM SIZE: 4"HIGH GEILING AREA. SECURITY ROLLING PLATED',UNLE55 OTHERWI5E NOTED. APPROVED EQUAL. FIRE RESISTANCE: ASTM E 84/NFPA 255(FLAME/SMOKE) -GLASS B, / TEMPERED PAINT V151ON 6RILLE TO REMAIN (450;A5TM E648/NFPA 253: GRITAL RADIANT FLUX-CLA55 1 14ALLGOVERIN6: / GLA55 PANE.TO UNLOCKED AND IN OPEN PANIG-1 ENTRY DOOR: PANIC BAR AT ENTRY DOORS SHALL BE 0 FLOOR STOPS SHALL BE #243F DOME STOP,U5261?BY HAGER PRIMER/51ZER: ZIN55ER-SHIELOZ UNIVERSAL PRE-WALLCOVERING / MATCH DOOR POSITION DURING STORE 5ECURITRON MODEL #T55-3BK TOUGH SENSE BAR,BLACK ANODIZED COMPANIES(800)325-9995. A.GRUSKIN RUBBER WALL BASE C,O JOHN50NITE MILLWORK RESILIENT WALL BASE- 45'MANCH AY MWTOP. WALL BASE;A PRIMER AT MINIMUM,WALLS SHOULD BE PRIMED AND SIZED AT / BUSINESS HOURS 36"FOR BRONZE/BLACK FRAME,MODEL#T5B-3CL TOUGH SENSE 4899 O CONTACT: LAURIE BAATZ (440) 313-8238 RECTANGULAR SHAPED PROFILE W/ X CHAMFER TOP. LEAST TWO(2)DAY5 BEFORE THE GRAPHICS INSTALLER ARRIVES. / BAR,CLEAR ANODIZED 36"FOR CLEAR FRAME,SUPPLIED AND • B-4 LAURIEBAATZeJOHN50NITE.GOM DOLOR: 40 BLACK;SIZE 3/8"THICK X 4 I/2°;FIRE RE515TANGE: ASTM CRITICAL RADIANT FLUX)-If I,A5TM E84/NFPA / 1 ALL DOORS AT RAIR TRA S AND JANITORS CLOSET SHALL BE E648/NFPA 253( GRAPHIC WALLGOVERING: _4 INSTALLED BY MSE CORPORATE SECURITY. UNDERCUT I"FOR AIR TRANSFER S NGFIELD,NJ 255 FLAME/SMOKE-GLA65 A/LESS THAT 450 SMOKE. PRIMED AND PAINT WITH A SEMI GLOSS,LATEX. AT MINIMUM PANIG-2 REAR DOOR(BACK AREA): PANIC HARDWARE AT REAR MERE RE5TROOM5 HAVE MULTI-FIXTURE5,DOOR SHALL HAVE ACOUSTICAL GEILING ARM5TRONG (WWWARM5TRONG.GOM) ARMSTRONG "l7UNE"#1115-2'x 2'x 5/8° WALLS SHOULD 8E PRIMED AND PAINTED AT LEAST THREE(3) U_ FRAME TYPE EXIT ODOR SHALL BE SEGURITEGH TRIDENT MULTI-POINT DEADBOLT PUSH/PULL PLATES BY HAGER GOMPMIE5(800)325-g115. PUSH �' TILE CONTACT: MAUREEN GONE PH: (103)389-2101 EDGE-BEVELED TEGULAR XbDAYS BEFORE THE GRAPHICS INSTALLER ARRIVES. Q LU EXIT LOCK,MODEL#TEL-EED32,SUPPLIED AND INSTALLED BY M5E PLATE SHALL BE 4'X16"STAINLE55 STEEL#305 BEVELED. FULL PLATE AGT-I MMGONE�ARMSTRONG.GOM COLOR- 'WHITE" "' CORPORATE SECURITY. GRID: SUPRAFINE XL 1/Ib'EXPOSED TEE GRID(WHITE) 2-10" SHALL BE 4"Xlb"5TAINLE55 STEEL#30 5ERIE5 WITH 10"PULL(33J),OR Consultant BENJAMIN MOORS CONTACT: 11_ APPROVED EQUAL. FIN15H SHALL BE 2bD(SATIN CHROME PLATED). FIRE RATINGS: GLA55 A MICHAEL EGKE w ELECTRIC,STRIKES SHALL BE VON OUPRIN STRIKE FORGE#6211 � FULLY WELDED Ib GAWE HOLLOW SERIES ELECTRIC STRIKE WITH FAIL SECURE OPERATION. CARD ACOUSTICAL CEILING ARMSTRONG (YMARM5TRONG.GOM) ARMSTRONG "FINE F15%RED'#1121 -2'x 4'x 5/8" (201)183-1658 METAL FRAME(KNOCK DOWN BOTH HAT HOOK AND SINGLE ROBE HOOK ON ALL RE5TROOM DOORS GRID: SQUARE LAY-IN 15/16" MIGHAEL.ECKE@BENJAMINMOORE.COM AA BB GG/HH GG FRAMES ARE OPTIONAL.VERIFY ACGE55 SHALL BE BY VERIZON WIRELE55 5ECURITY VENDOR. IF NO TILE CONTACT: MAUREEN GONE PH: (103)389-2101 WITH VERIZON WIRELESS PRO.EGT CARD ACCESS IS PROVIDED IN STORE,PROVIDE SEIFER-TYPE SHALL BE REFERRED TO GENERAL NOTES,SECTION 1028.00. M AGT-3 MCONE®ARM5TRONG.COM COLOR: "WHITE" KICKPLATE WERE GRID: PRELUDE XL 15/I6'EXP05M TEE IN WHITE 3 6 SPECIFIED) MANAGER) LLGKSET ON INVENTORY ROOM DOERS. ROLLING DOOR(GG) AT INVENTORY ROOM SHALL BE MODEL#URD-3 FIRE RATINGS: GLASS A CORNER GUARDS I I/2'LEG X 8'-0'H CORNER GUARD ODOR FRAMES SHALL HAVE RUBBER SILENCERS,WHICH ARE TO BE MANUFACTURED BY OMI,KEVIN BEC AT I-800-446-2500 E-MAIL: CORNER GUARDS IMPACT SPECIALTIES: CORSER MODEL: VA2 '- W/TAPE;INSTALL ABOVE WALL BASE INSTALLED AFTER FINAL PAINTING. SILENCERS SHALL BE#3010, KBECERRA®QMIU5A.GOM. ROLLING DOOR SHALL BE INSTALLED A5 CONTACT: MICHELLE GG-I P: 108.841.3013;F: 510.435.2110; COLOR: P+ #181 MIDSUMMER NIGHT PER MANUFACTURER'S SPECIFICATIONS. GRAY,BY HAGER COMPANIES (800)325-1115. a EMAIL: M8UEHLER®G-5GROUP.COM LOCATION: FRONT OF HOUSE® 11ALL5 WITH P-6 CORNER GUARD IMPACT SPECIALTIES: CORNER GUARDS 11/2'LEG X 8'-O°H GARNER GUARD CONTACT: MICHELLE BUEHLER MODEL: VA200 W/TAPE;INSTALL ABOVE WALL BASE ROOM FIN15H 5GHEDULE Joh Name and Number.cu GG-2 P: 0108.84q.3013;F: 570.435.2110; COLOR: P-1.#014`1 BRILLIANT WHITE 2015-0131 CU EMAIL: MBUEHLER@G-5GROUP.GOM LOCATION: FRONT OF HOUSE @ WALL5 WITH P-1 CORNER GUARD IMPACT 5PEGIALTIE5: CORNER GUARDS 11/2'LEG X 8'-O'H CORNER GUARD ROOM NUMBER NAME FLOOR BASE WALLS GEILING CABINETRY COUNTERTOP COMMENTS Proposed GG-3 CONTACT: MICHELLE BUEHLER MODEL: VA200 W/TAPE;INSTALL ABOVE WALL BASE NOTE: 101 RETAIL SALES G-I,PT-b B-I,B4,PT-6 P-b,P-1,P-8 AOT-1 - VERIZON P: g08.84`13013;F: 510.4352110; COLOR: P-8.#108 BLACK d EMAIL: MBUEHLER®G-SC-MP.COM LOCATION: FRONT OF HOUSE® WALL5 WITH P-8CONTRACTOR TO PROVIDE AGM PANEL 102 OPEN OFFICE C-1 B-3 P-q,WG-I ACT-3 L-5 L-5 *PROVIDE AG-I TO+48'AFF.PAINT WALL P-q ABOVE WG-I ~ 103 BREAK AREA G-1 B-3 P-q,WC-I ACT-5 L-5 L-5 *PROVIDE WC-1 TO+48'AFF.PAINT WALL P-q ABOVE WG-I STORE W SHOP DRAWINGS TO ARGHITEGT PRIOR TO VERIZON NIRELE55 5TORE MATRIX - PNW MILLWORK FINISHES FABR I GAT I ON. 104 ELEC. (LEED)ROOM SLAB B-3 P-q AGT-3 -- - SUPPLIED BY INSTALLED BY ITEM SYMBOL ITEM MANUFACTURER SPECIFICATION AND COLOR 105 MANAGER G-I B-3 P-q T- -- VERIZON VERIZON VERIZON GENERAL VERIZON GENERAL 106 INVENTORY G-I B-3 P-q AGT-3 A -- -- WIRELESS WIRELE55 w AIRELE55 VENDOR CONTRACTOR WIRELE55 VENDOR CONTRACTOR PLASTIC LAMINATE INIL50NART WIL5ONART LAMINATE#011-60 ALL METAL PANEL SIZES SHALL BE ** * _ _ *PROVIDE WG-1 TO+48'AFF.PAINT WALL P-q ABOVE WG-1 � 101 WOMEN5 ROOM V5F-I V5F-I P-q,WG-I GYP.BD.(P-1) L-I CONTACT: LESLIE REED HUMPHREY (614)813-6853 DOLOR: "SLATE GRAY" **WRAP SHEET VINYL 6"MINIMUM UP WALL • BOTTLELE55 KATER COOLER VERIFIED I N FIELD BY GONTRAGTOR *PROVIDE SHEET IN+48"AFF.PAINT WALL P-q ABOVE WG-I HUMPHRL®WIL50NART.GOM FINISH: MATTE108 MENS ROOM V5F-I **Y5F-I P-q,WG-I* GYP.BD(P-T) - - **y�Ap SHEET VINYL 6'MINIMUM UP WALL • TELCO RACK Jon Address: to PLASTIC LAMINATE WIL50NART COLOR- 'CANYON ZEPHYR'#4842-bo PRIOR TO EABRIGATION. IOq TELCO SLAG B-3 P-q ALT-3 -- -- • PHONE PANEL Washington Square Mall C) L-5 (800)433-3222 FINISH-MATTE • • FIRE EXTINGUISHERS 1 FIRE RATING: GLA55 I OR TYPE&04,605 AND 601 • •CD REFRIGERATOR-ENERGY STAR 9585 S.W. Washington Square Road • • MICROWAVE Portland, OR 97223 Z STOREFRONT COLOR CHART BILPAYMENT MH Space R05-R07 KEY MANUFACTURER I MANJFALTURER 2 • • COPIER A HARDWARE MANUFACTURER: KAMEER MANUFACTURER: ROLKWOOD A55A ABLOY Z WWW.KAWNEER.GOM WWW.R.OGKWDODMFG.GOM EXTERIOR ALUMINUM COMPOSITE PANG.COLOR CHART " • • MOVABLE FURNITURE DESKS,CHAIRS,ETC, DrarvingTitle: 3 5/8 METAL STUD • • TELEPHONE 5Y5TEM o SERIES: ARCHITECTS CLASSIC PRODUCT: RM 258(12"ANGLE 50LID PULL) KEY MANUFACTURER I MANUFACTURER 2 INVENTORY SIDE FRAMING(TYP) • • GOMPUTER/DATA SYSTEM U PRODUCT: STYLE 6012 BASE MATERIAL: 5TAINLE55 STEEL 303/304 MP-5 MANUFACTURER: ALPOLIG MITSUBISHI PLASTICS GOMP051TES AMERICA; WWWALPOLIC-USA.GOM � FINISH: SATIN FIN15H: SATIN PRODUCT: 4MM4BGY35 " • • POS DESK EQUIPMENT Door, Fixture CONTACT: (ql1)50q-Sgbb CONTACT: 800)458-2424 COLOR: B6Y GREY 3/4 FIRE DOOR N.A. LOCKING THERMOSTAT GONERS E3 ( CONTACT: DAVE KEARNY, RETARDANT • • SECURITY SYSTEM and Finish Schedules U DAVE@ALPOLIG.GOM PLYWOOD • • SECURITY CHEST/SAFE CU (151)381-5124 5/8"CARRIAGE DOOR JAMB z LEED NOTES: BOLT MIN 5 • • INVENTORY SHELF UNITS & SLATWALL/PEGBOARD 3 NOTE: BOLTS PER SIDE. • • T-I PHONE LI CONDUIT BY GG Drawr.Bi: North A ALL CARPET PRODUCTS SHALL MEET THE REQUIREMENTS OF GRI GREEN LABEL PLUS PROGRAM. • GH05E EITHER METAL PANEL MANUFACTURER • • ISDN LINE CONDUIT BY GG JL Arrow nil ANY SUBSTITUTIONS TO THE CARPET PRODUCT SPECIFIED MUST MEET THE LEED REQUIREMENTS LISTED IN LEED SPECIFICATION SECTION 'FLOORING'ON SHEET A13. CONTRACTOR MUST USE SAME MANUFACTURER FOR ALL METAL PANELS NUT AND WASHER • • TRASH CANS KG By: CONTRACTOR MAY : . KG W • • INTERIOR DIRECTIONAL 51GNAGE* Date Issued For CARPET AND CARPET PAD ADHESIVES SHALL HAVE A MAXIMUM VOG CONTENT OF 50 G/L. AGM PANEL GUIDELINES 5/8"GYPSUM BOARD Client 12/24/15 • • LIGHT FIXTURES I.PANEL SIZES TO BE BETWEEN 3'-0'-4'-8'A5 REQUIRED FOR EQUAL PANEL SIZES. ROLLING DOOR • • RESTROOM AGGE550RIE5 Landlord: 12/24/15 ALL HARD SURFACE FLOORING MUST BE CERTIFIED AS COMPLIANT WITH THE REQUIREMENTS OF THE FLOOR56ORE STANDARD A5 5HOWN WITH TESTING BY AN INDEPENDENT THIRD PARTY. 2.ALL SEAMS AT RED AND WHITE AGM PANELS TO BE VERTICAL. 1/2" 3-6 WIDE X 8-0 HIGH(V.I.FJ • • IN STORE MUSIC,SYSTEM Permit: / /15 H 3.AGM PANELS COME IN STANDARD SIZES OF 5'-0"X I6-0". EXTRUDED ALUMINUM SEE DOOR 50HEDULE a ALL PAINTS,COATINGS,PRIMERS,SEALERS,CLEAR WOOD FINISHES AND 5HELLAC5 SHALL MEET THE VOG LIMITS SPECIFIED UNDER INDOOR AIR QUALITY MANAGEMENT ON THE LEED PROTOTYPE - IF THE RED BALKER 15 3-0 TALL OR UNDER,THE ENTIRE BACKER SHOULD BE ABLE TO BE FABRICATED OUT OF WINDOW SHADES GREEN SPECIFICATIONS. I-2 SHEETS OF METAL. GUIDE BY MANUFACTURER Construction: • • WINDOW FILM Revision Issue: W 4.OVERALL METAL PANEL THICKNE55 SHALL BE 13/4"WITH MOUNTING SPACE AND METAL COMPOSITE THICKNESS NIGHTTIME ROLLING SECURITY a CONCRETE FLOOR FINISHES SUCH A5 SEALER,5TAIN AND FIN15H MUST MEET THE REQUIREMENTS OF THE SOUTH COAST AIR QUALITY MANAGEMENT D15TRIGT(5GAQMD)RULE 1113,ARCHITECTURAL SHALL BE 4MM(0.151'). • • 50LAR FILM No. Date Description • • MARKER BOARDS/TRACK BOARDS 0 COATINGS,EFFECTIVE JANUARY 1,2004. REFER TO THE VOG LIMITS TABLE ON THE LEED PROTOTYPE GREEN SPECIFICATION. GRILLE - PLAN DETAIL 0 SUBSTITUTIONS FOR ANY STANDARD FINISHES LISTED HERE SHALL BE SUBMITTED TO AND APPROVED BY GGA ARGHITEGTIIRE AND THE GONSTRUGTION PROJECT MANAGER FOR LEED REQUIREMENT5. 1 • • RECYCLING CONTAINERS SGALE: 3" = V-O" NOTE: BOTTOM OF HOOD @ 8'-0'A.F.F. • • 13 WATT PLUG-IN TASK LAMP z_ REFER TO REQUIREMENTS L15TED UNDER THE SUBSTITUTIONS HEADING ON THE LEED PROTOTYPE GREEN SPECIFICATION. • • CARPET G-I t" FOR PAINT AND SEALANT AND ADHE5IVE PRODUCTS: • • NYL SHEET FLOORING Dr CONTRACTOR SHALL COMPLETE THE VOG SUBMITTAL FORM AND PROVIDE MATERIAL SAFETY DATA SHEETS(M5125)HIGHLIGHTING THE VOG CONTENT. • • NON-GRAPHIC WALLGOVERI2 Q GG-3 • • CORNER GUARDS CG-I,GG-2 FOR FLOORING PRODUCTS: CONTRACTOR SHALL COMPLETE THE MATERIALS SUBMITTAL FORM AND PROVIDE CUT 5HEET5 OR OTHER DOCUMENTATION FOR EACH FLOORING PRODUCT,HIGHLIGHTING • • WALL I DOOR PAINTS RECYCLED CONTENT INFORMATION. • • WALL BA5E5 (U Z 3 FOR WOOD AND WMP051TE WOOD PRODUCTS: CONTRACTOR SHALL COMPLETE THE MATERIALS SUBMITTAL FORM AND PROVIDE GUT 5HEET5 OR OTHER DOCUMENTATION FOR EACH WOOD PRODUCT ❑�' HIGHLIGHTING RECYCLED CONTENT INFORMATION. • • P G RD T t EXIT 000 • • DOORS 4 DOOR HARDWARE FOR ALL OTHER PRODUCTS: CONTRACTOR SHALL COMPLETE THE MATERIALS SUBMITTAL FORM AND PROVIDE GUT SHEETS OR OTHER DOCUMENTATION FOR THE PRODUCT/MATERIAL HIGHLIGHTING • • SECURITY SHUTTERS AT INVENTORY W w RECYCLED CONTENT INFORMATION. • • SMART BEARD • • METAL EMPLOYEE LOCKER DravAng Number, 3 X 0 GOPIE5 OF ALL SUBMITTAL FORMS REFERENCED ABOVE CAN BE FOUND ON THE LEED PROTOTYPE GREEN SPECIFICATIONS. *VERIZON WIRELESS'MINIMUM REQUIRED INTERIOR DIRECTIONAL STORE SIGNAGE(DEPENDING ON STORE LAYOUT)SHALL BE X o -ADA RESTROOM; -ADA ROOM ID(ELECTRICAL CLOSET); Z¢ -WAYFINDER: HANGING WAIL OR FREESTANDING -CUSTOMER SERVICE DIRECTIONAL SIGNAGE* (yo GENERAL CONTRACTOR 15 RESPONSIBLE TO COORDINATE WITH VERIZON INIRELE55 VENDOR5 FOR 5ECURITY,OATA/rELGO,516N5,MILLWORK,AND MERCHAN0I51N6. A10 W >to I o 12 OF 31 -5 CU BOTTOM OF MALL +32'-0" CEILING � � J BOTTOM OF MALL +I6'-0' BOTTOM OF MALL Jk +I6-0' BULKHEAD V.I.F. BULKHEAD 1V V.I.F. GRUSKIN COOL GRAY ALUMINUM GRAY ALUMINUM COMP051TE COMPOSITE PANEL(MP-5) PANEL(MP-5) ARCHITECTURE 294 Morris Avenue Springfield,NJ 07081 ANGLE BRACING AT 48" Tel: 973.376.441 1 Fax: 973.376.8989 ANGLE BRACING AT 48" 1/2"THICK FIRE RETARDANT ^W^r Grusl<inGroup.com NJ REG 0100-9869-14 O.G. TO STABILIZE 1/2"THICK FIRE RETARDANT D.G. TO STABILIZE ENTRY STRUCTURE PLYWOOD STRX� PLYWOOD This document and the Ideas and designs Incorporated DOORS herein, as an Instrument of professional service,Is the propenyof GRUSKIN ARCHITECTURE+DESIGN,P.C.,and Is not to be used In whole or In part for any other project without the written authorization of GRUSKIN ARCHITECTURE+DESIGN,P.C. 3'DEEP HALO ILLUMINATED,WHITE LED.REVERSE All Rights Reserved 3 50'METAL 5TUD 3 5/8"METAL STUD ©2015 Gruskin Archltecture+Design P.C. CHANNEL LETTERS PINNED 0/2"OFF OF FACADE. FRAMING AT 16'O.G.(TYP) FRAMING AT 16°O.G.(TYP) Kenneth A. Gruskln AIA LETTERS SHALL BE AHITE FACES AITH WHITE RETURNS AND CHECK MARK SHALL BE RED FACE WITH RED F71AL 5416 NT 9537 t RETURN.SIGN SHAM HAVE AN 18"HIGH "V'. • • • • AK 13167 C 961 ------------- TOP OF STOREFRONT +10'-0" ----- i - - TOP OF STOREFRONT +ID'-0" ------------------- ------- 141-1 1 141-1 AR 3811 66 PROVIDE 3/4"ALUMINUM TOP OF STOREFRONT +I6'-0" CGYP5UM BOARD 5U5PEN510N 6YP5UM BOARD AZ 39209 NDE A6 3547 VERTICAL REVEAL CHANNEL 5Y5TEM WITH 5/8" GYPSUM COOL GRAY ALUMINUM 5U5PEN51ON 5Y5TEM WITH COOL GRAY ALUMINUM CA C-29898 NH 2796 PANEL 5EAM. CONTRACTOR TO BOARD (P-1) COMPOSITE PANEL(MP-5) 5/8" GYPSUM BOARD COMPOSITE PANEL(MP-5) CO RC-400347 NJ Al 09999 10'-41/2" CT 9613 NM 004168 516N PROVIDE SHOP ELEVATIONS WITH COOL GRAY ALUMINUM 7 (P-1) DC ARC100723 NV 5521 EX15TING LOCATION OF FINAL LOCATIONS FOR APPROVAL COMPO51TE PANEL(MP-5) DE 0006261 NY 025528-1 NY LEASE LINE MP-5 COOL GRAY ALUMINUM I/2"THIGK,GLEAR TEMPERED FL R91629 OK a4895 m p ❑ HA RD 110489 OR 48991 z LEASE LINE OF NEW SPACE COMPO51TE PANEL FRAMELE55 GLA55 BEYOND COOL GRAY ALUMINUM `� � ( -5) ID ARIA 7984459 PR 113 PA 199655432-B COMPOSITE PANEL(MP-5) 4 I/2"THIGKGLEAR IL 001-019152 RI 2666 TDP OF STOREFRONT +10'-0" / IN AR10400066 SC 6834 TEMPERED KS 4674 SD 11532 FRAMELE55 GLA55 / KY 5967 TN 101374 i LA 5734 TX 17680 VA / \VA ME ARC 2596 LIT 5881358-0301 / \ MD 11016 VF 2572 / PROVIDE 3/4'ALUMINUM VERTICAL MA 10635 VA 0401 011223 MI/ \ REVEAL CHANNEL MN 44332652379 WA 99004005 / \ MO A-2005029740 WV 3727 / \ COOL GRAY ALUMINUM I/2"THICK,GLFAR TEMPERED MS 3860 WY C-1967 COW051TE PANEL.(4P-5) FRAMELE55 GLA55 Professional Seat: \ / FIN15HED FLOOR J�0'-0' FASTEN COOL GRAY ALUMINUMA.GRUSKIN I-b r u °2-0 EQUAL EQU EQUAL EQUAL 2'-0- I-6 COMPOSITE PANEL(MP-5)TO 1/2 n „ COOL GRAY ALUMINUM THICK FIRE RETARDANT PLYWOOD COMPOSITE PANEL 16 4899 PROVIDE KEY LOCK AT BOTTOM RAIL AND 2 1/2'METAL STUD FRAMING AT BEYOND(MP-5) SPRINGFIELD,NJ ` 16'O.G. TYP. 3/4"x 1/2"METAL CHANNEL,PAINTED BLACK,TVP. CSF 1 STOREFRONT ELEVATION Consultant SCALE: 1/4" = 1'-D" 0=14YVALL SECTION 6 WALL SECTION ' M_ r 6 ALIGN 1 r CU 1/2'THICKGLEAR TEMPERED FRAMELE55 GLA55 2015-0131 loame an b Nd Number CUr — — — — ALIGN I NEOPRENE A5 REQUIRED Proposed 2 1/2"METAL STUD FRAMING Ld ® I6'D.G. V E R T ZO N ENTRY( w D-) — — — — EQUAL "A' EQUAL 'A' EQUAL 'A" DOORS 4 EQUAL "B" EQUAL "B" EQUAL 'B' EQUAL 'B' EQUAL "B" — — — 4 — — 1PLYAOOD FIRE RETARDANT STORE FOCAL KALL 2'o -0" Ib'-6 I/2' I-O. b'-0° 1'-0" 2-0 I-6 � % -METAL PANEL(GREY),TVP. (LEED) ;D 1/2'AIR SPACE(TYP) W PARTIAL PLAN 3/4"x 1/2"METAL CHANNEL, � PAINTED BLACK,TYP. M I s FASTEN COOL GRAY ALUMINUM Job Address: o PANEL(MP-5)TO PLYWOOD AND SECTION DETAIL AT I ASE Washington Square Mall N MOUNTING 5Y5TEM BY FABRICATOR _ 9585 S.W. Washington EXISTING DEMISING WALL EXISTING DEMISING HALL SCALE: 3" - 1'-0" TO REMAIN(HATCHED 1/2'THICK,FIRE RETARDANT PLYWOOD TO REMAIN(HATCHED Square Road w ARES 3 50'MTL.STUD FRAMING® 16'O.C. ARM Portland, OR 97223 5/5"GYP5UM BD.ON 2'-0' (TYP) 2'-0 1 1 5/5'GYP5UM BD.ON NOTE: Space R05-R07 a METAL 5TUD5 FRAMING 1/2'THICKGLEAR TEMPERED METAL STUDS FRAMING SIGNAGE WILL REQUIRE SEPARATE PERMIT. 516N CONTRACTOR SHALL SUBMIT ALL 51GN DRAAI%5 TO TOWN OR z FRAMELESS GLA55 - CITY FOR APPROVAL. DravdngThle: - --- COOL GRAY ALUMINUM PANEL(MP-5) --- `~ BELOW z 516NA6E GALGULATION GNART Exterior Elevations z 07 17 L) _________________ ------------------ AS PER ZONINGGODEOFGcu 4 ITY v 516NA6E GRITERIA LOCATION ALLOYED PROP05ED I 1 SEE PLAN SEE PLAN 21-011 I I PROVIDE 3/4"ALUMINUM 60 LF X 2/3 = WALL 516NA6E CRITERIA(LANDLORD): MAX.516N AREA SIGN AREA 23.12 5Q.FT. VERTICAL REVEAL CHANNEL 40.02 5Q.FT. Drawn Y. North ALL STOREFRONT 51616 M15T BE ILLUMNATED.INTERNALLY ,1 Arrow. a PROVIDE 3/4 ALUMINUM Q ILLUMINATED RZA-FACED GHAw6L LETM ARE 40.02 5F=2.31 = L Q 1 - FRONT ELEVATION MAX.LENGTH OF SIGN LENGTH OF SIGN 10'-4 I/2" Checked By. `/" VERTICAL REVEAL CHANNEL — I o o — I�TED. 11'-31/2" — — I REVERSE CHANNEL LETTERS ARE TO BE A MINIKH OF 3' , KG C3 I DEEP. Ib-0 MAX.HT.OF LETTER h x 13% = HEIGHT OF LETTER 24.31" Date Issued For I I BOTTOM OF 516N TO BE A MINIMUM OF 4'-0"AFF. 24.96" Client: 12/24/15 PANEL(MP-5) �—————————————————— ———— " STOREFRONT LETTER FEI6Hr 15 To BE 13%OF THE � -----J L----------- Landlord: 12/24/15 2'-0' ( 2'-0" ° 516%AREA 15 MEAE%FED BY CIRLUMSGRIBIN6 A BOX PLAN PETAI L AT �` PLAN PETAI L AT AROUND THE MAIN BODY of THE 5i&K Biedrmit: 12/24/15 J ° MAXIKM 516N AREA PERHTTED 15 CALCULATED BY INTERIOR MALL LOCATION INTERIOR MALL LOCATION MA-TIPLYI Construction: MAXIMIM SIGN WIDiH 5 CALCULATED ATED BY DIVIDING THE Revision Issue: 11�Li 3 MAXIRH PERMITTED 516N AREA BY THE MAXIMUM LETTER SCALE: 1 1/2" = 1'-0" SCALE: 1 1/2" = 1'-0" No. Date Descr�pdon HEIGHT of THE PROPOSED 516K c� z 0 LD K TYPICAL METAL PANEL PETAIL5 31/4 It I Q 3 FRAMING FRAMING FRAMING FRAMIN6 BACKER ROD CD ro FRAMING AND SEALANT to SHEATHING SHEATHING SHEATHING w C) SHEATHING NG SHEATHI (U Z L3 _ ALUMINUM/METAL Z — - I A — — — — — — — — — — — — — — — COMPOSITE PANEL5 CIN 00 VARIESALUMINUM/METAL ALUMINUM/METAL VARIES. VARIES. —ALUMINUM/METAL 3 X COMPOSITE PANELS COMPOS COMPOSITE PANELS 3/4"X I/2°METAL VARIES Drawing Number. X 3/4"x 1/2"METAL BUTT JOINT CHANNEL,PAINTED ALUMINUM/METAL ALUMINUM/METAL X.-, CHANNEL,PAINTED BUTT JOINT BLACK,TYP. COMPOSITE PANELS COMP051TE PANELS Z a BLACK,TYP. UCDl) C WRAPPEP PANEL END TERMINATION �1���1�?NT GLA55 @MALL8 ND TERMINATION @ 1N �ERTIGAL JOINT TERMINATION @GRADE o SCALE: 3" = 1'-0" 5CALE: 3" = 1'-0" SCALE3" = 1'-0" SCALE3" = 1'-0" N 13 OF 31 GRUSKIN / DESIGN,ARCHITECTURE + O 294 Morris Avenue Springfield,NJ 07081 Tel: 973.376.4411 Fax: 973.376.8989 www.G ruskinGroup.com NJ REG 0100.9869.14 This document and the Ideas and designs Incorporated iv herein,as an Instrument of professional service,Is the �— property of GRUSKIN ARCHITECTURE+DESIGN,P.C.,and Is not to be used In whole or In part for any other project m Q n � without the written authorizadon of GRUSKIN Q - ARCHITECTURE+DESIGN,P.C. All Rights Reserved ©2015 Gruskin Architecture+Design,P.C. ti ��1� �F�� Kenneth A. Gruskin AIA AL 5421 MT 2537 AK 13167 NC 9961 AR 3811 ND 1666 AZ 39209 NE A-3547 CA C-29898 NH 2796 FLOOR LINE CO ARC-400347 NJ Al 09999 CT 9613 NM 004168 DC ARC100723 NV 5521 DE 0006261 NY 025528-1 NY FL AR91629 OK a4895 5X-015 SX-01M 5X-02 SX-05 SX-07 SX-15 GA AR 11 75 OH 13761 HI AR 11489 OR 4899 ESSENTIALS PEDESTAL SHORT ESSENTIALS PEDESTAL MEDIUM FEATURE CUBE A 66ESSORI ES YNA�LL BRAND MONOLITH DEVICE DI5PLA�Y YELL IA AR-9 PA 19965 432-B ID AR-984459 PR 19965 IL 001-019152 RI 2666 IN AR10400066 SC 6834 KS 4674 SD 11532 KY 5967 TN 101374 LA 5734 TX 17680 ME ARC 2596 UT 5881358-0301 MD 11016 Vi 2572 MA 10635 VA 0401 011223 MI MN 44032652379 WI 99004005 12,E MO A-2005029740 WV 3727 MS 3860 WY C-1967 Professional Seal: ! CEILING LINE � ® MONITOR LOCATION 5X-46L o FOR 5X-22M OR A.GRUSKIN m r • 4899 • m o RINGFIELD,NJ / Cj m o 1 r- FLOOR LINE m ConsultanC v 5X-16 � 5X-16ADA SX-20 5X-21 5X-22 SX-22M 5X-24 (GOMPRE55EP) SX-46L OR 5X-465 6A54NRAP P05 MY VERIZON EXPRESS COUNTER VERIZON SERVICES PANEL HOMES SOLUTIONS FREESTANDING PANEL SMART ZONE FREESTANDING DISPLAY YELL BRAND FOGAL 1NALL LIGHT BOX N Job Name and Number, 2015-0131 1 (U J Proposed -8 VERIZON W z Z STORE (LEED) W LLJU 0 a o !. n, .Mr ®a � lob Address Washington Square Mall LO N N 9585 S.W. Washington Square Road Portland, OR 97223 W Space R05-1307 U O P Drange: z FRONT ELEVATION LEFT 510E ELEVATION Fixture List U F- H N z 13 BPK CLJ 1-1 0 BILL PAYMENT 1<1051< Z_ Drawn By. North 3 �L Arrow. lY Checked By. N KG 0 Date Issued For o Client: 12/24/15 to Landlord: 12/24/15 Permit: 12/24/15 ►= Bid: I J J Construction: Revision slue: W No. Date Description Q' C'S V1 Z C H L Z 2 ¢ Dr M O I to O (U Z LD 03 WA o v, - iW F-Q 0 F W F— Drawing Number: 3 x� X i r+ z� 0 �o WI I C3 14 OF 31 �(U PLUMBING SYMBOLS GENERAL PLUMBING NOTES: NOTE: THIS IS A MASTER LEGEND AND NOT ALL SYMBOLS, 1 1. DRAWINGS ARE DIAGRAMMATIC ONLY AND REPRESENT THE GENERAL SCOPE ABBREVIATIONS, ETC. ARE NECESSARILY USED ON THE DRAWINGS. 2 3 OF THE WORK. PRIOR TO SUBMITTING BID, VISIT THE JOB SITE TO OBSERVE THE PIPING EXISTING CONDITIONS OF THE PROJECT. REVIEW THE GENERAL NOTES, SPECIFICATIONS, AND PLANS FOR ADDITIONAL REQUIREMENTS THAT MAY NOT DOMESTIC COLD WATER (CW) (7 a v BE SPECIFICALLY CALLED OUT IN THIS PORTION OF THE CONSTRUCTION GRUSKIN DOMESTIC HOT WATER (HW) DOCUMENTS. NOTIFY VERIZON WIRELESS CONSTRUCTION MANAGER OF ANY CONFLICTS OR DISCREPANCIES PRIOR TO SUBMISSION OF BID. T TRAP PRIMER LINE (T) S SOIL PIPING - ABOVE FLOOR (S) WHA M 2. PROVIDE TO THE VERIZON WIRELESS CONSTRUCTION MANAGER A COPY OF --S-- SOIL PIPING — BELOW FLOOR S 3/4"CW =�,_� INSPECTION REPORTS AND APPROVAL CERTIFICATES FROM LOCAL AND STATE 294 Morris Avenue Springfield.NJ 07081 ( ) [i— II II° INSPECTIONS, REFER TO SPECIFICATIONS. Tel: 973.376.4411 Fax:973.376.8989 W WASTE PIPING — ABOVE FLOOR (W) WCO 6 WM 5 J_ www.GruskinGroup.com NI REG 0100.9869-14 WC1 TECO 3. INSTALLATION SHALL COMPLY WITH LEGALLY CONSTITUTED CODES AND THE --W-- WASTE PIPING — BELOW FLOOR (W) CR REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION AND ALSO MEET ALL This document and the ideas and designs incorporated V VENT PIPING (V) �f 1.C. 1 109 REQUIREMENTS OF THE LANDLORD. OBTAIN A COPY OF THE LANDLORD'S herproein,as n IInstruSKIN ment of professional DESIGN,P.C.,(anile ( ) WHA I FD - 3 "CD is REQUIREMENTS AND REVIEW PRIOR TO SUBMITTING BID. is not to be used in whole or in part for any other project CD CONDENSATE DRAIN CD without the written authalzationof GRUSKIN G NATURAL GAS (G) I 1/2"CW v o I 4. PLANS AND SPECIFICATIONS GOVERN WHERE THEY EXCEED CODE ARCHITECTURE+DESIGN,P.C. —— ——G———— NATURAL GAS ON ROOF G) - - --- - — --.... REQUIREMENTS. Reserved ( ZC — TP ——— — ©2015 Gruskin Architecture+Design,P.C. FP FIRE PROTECTION (FP) NIROM CDB 5. VERIFY LOCATION AND DEPTH OF UTILITIES AT POINTS OF CONNECTION BEFORE 1 8 START OF PIPING INSTALLATION. K�Ih A. all" AIA PD CONDENSATE PUMP DISCHARGE (PD) — — — AL 5421 WT 2537 EXISTING PIPING TO BE REMOVED 6. REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATION AND MOUNTING I I WHA OM S 4"CD I I AK 13167 INC 9961 EXISTING PIPING TO REMAIN OOM — _J HEIGHTS OF PLUMBING FIXTURES. AR 3811 ND 1666 MANAG I 1/2"CW --- AZ 39209 NE A-3547 ® ROUND FLOOR DRAIN (FD), SIZE & TYPE 07 7. DO NOT SCALE FLOOR PLANS FOR EXACT HORIZONTAL LOCATION OF PIPE CA C-29898 NH 2796 C SINK1 ROUTING. CCO ARC-400347 3400347 NM 0041689 � BALL VALVE 105 I WH I CONTROL VALVE EWH EWH1 FD 8. INSTALL CONCEALED PIPING TIGHT TO THE STRUCTURE AND AS HIGH AS DC ARC100723 NV 5521 THREE—WAY CONTROL VALVE I ©UI t POSSIBLE. INSTALL EXPOSED PIPING TIGHT TO THE STRUCTURE, WALL, OR DE 0006261 NY 025528-1 NY CEILING AND AS HIGH AS POSSIBLE. COORDINATE WITH OTHER TRADES TO FL AR91629 OK a4895 SHUTOFF VALVE �— r AVOID CONFLICTS. GA RA011075 0 13761 P' HI AR 11489 OR 4899 CHECK VALVE j ? _ ________i__ __i___----i_ o IA 05713 — —B s. --- -1---- ------ 3 4 C WC1 9. VALVES SHALL BE LINE SIZE UNLESS OTHERWISE NOTED. ID AR-984459 PR 19965 WATER METER s NK2 INVENTORY IL 001-019152 RI 2666 PRESSURE REDUCING VALVE -- - 10. PIPING IN FINISHED AREAS SHALL BE ROUTED CONCEALED; EXPOSED PIPING, IN AR10400066 SC 6834 1/2 CW — 1 CW — — 106 WHERE NECESSARY, SHALL BE ROUTED AS HIGH AS POSSIBLE AND TIGHT TO KS 4674 SD 11532 GAS PRESSURE REGULATOR BREAK AREA I I WALLS. KY 5967 TN 101374 W THERMOSTATIC MIXING VALVE 11 I E ARLA C2596LIT 5881TX 8358-0301 1 D3 I I 1 1. COORDINATE ALL WORK WITH OTHER TRADES AND CONTRACTORS. BACKFLOW PREVENTER I I OPEN OFFICE I MD 11016 VT 2572 C. ROOM 13 4"CD MA 10635 VA 0401 011223 UNION — ( 102 12. COORDINATE PIPING INSTALLATION WITH STRUCTURAL GRADE BEAMS, MI 1301052379 WA 10344 1 ( FOOTINGS, COLUMN PIERS, ETC. SLEEVE PIPING THROUGH GRADE BEAMS, MN 44326 WI 9900-005 FLANGE CONNECTION 04FOOTING, ETC. WHERE REQUIRED AND AS NOTED ON PLANS. COORDINATE MO A-2005029740 WV 3727 HOSE BIBB (HB) SLEEVE INSTALLATIONS WITH THE ARCHITECT, STRUCTURAL ENGINEER, MS 3860 WY C-1967 CLEANOUT STRUCTURAL CONTRACTOR, AND GENERAL CONTRACTOR BEFORE CONCRETE IS P,o{�p,g�; INSTALLED. CAP u � 0-II WALL CLEANOUT (WCO) VB1 13 OVERCLEAN OWNER.AERATORS AND PIPE STRAINERS PRIOR TO TURNING BUILDING �\�,� XA NR��ss �0 O FLOOR CLEANOUT (FCO) 0 0 o o ELBOW UP I I 14. COORDINATE PIPE ROUTING AWAY FROM ELECTRICAL PANELS. DO NOT — --- -------- -------- -------- -------- -------- -------- ------- I INSTALL PIPING OVER ELECTRICAL PANELS. ro ELBOW DOWN CO I 15. PAINT ALL EXPOSED GAS AND WATER PIPING USING RUST INHIBITOR PAINT. TEE UP `� PAINT AND COLOR SHALL BE COORDINATED WITH THE ARCHITECT AND / OR ,o „ O E N o TEE DOWN `�' `� L iI OWNER. xx Q rQ ELBOW UP WITH SHUT—OFF VALVE (SOV) 14 I 16. COORDINATE ALL ROOF PENETRATIONS WITH OTHER TRADES. MAINTAIN 15' ELBOW DOWN WITH SHUT—OFF VALVE (SOV) — i — — — — — — — — — — — — MINIMUM CLEARANCE FROM ALL AIR INTAKES. MAINTAIN 2' CLEARANCE I ___ ___ ___ I FROM ALL OTHER EQUIPMENT. EXPIR S: 1 ri5r TEE UP WITH SHUT—OFF VALVE (SOV) I � �i i � �i i � �i i � `� I /2 TEE DOWN WITH SHUT—OFF VALVE (SOV) --T i i it I i iI i it O '�` i 17. ROOFING PENETRATIONS MUST BE DONE BY LANDLORD APPROVED ROOFING consultant A , \\ I CONTRACTOR TO MAINTAIN ROOF WARRANTY. * WATER HAMMER ARRESTER (WHA) WITH PDI SIZES, (A, B, C, D, & E) �o P-TRAP 18. PLUMBING FIXTURES TO BE FURNISHED AND INSTALLED BY PLUMBING I CONTRACTOR UNLESS NOTED OTHERWISE. HENDERSON I I I GAS COCK J y ENGINEERS I I I 19. PROVIDE PLUMBING FIXTURES IN RESTROOMS AND WATER HEATER INCLUDING TRAP PRIMER I PIPE CONNECTED TO EXISTING UTILITIES, BRANCH PIPING TO FIXTURES, AND 3N 0 TRAP PRIMER WITH DISTRIBUTION UNIT i i ° F=—1 O i ° SHUTOFF VALVES AS SHOWN ON PLAN UN LESS EXISTING. PROVIDE BACKFLOW 8345 LENEXA DRIVE,SUIT E 300 I I RETAIL SALES PREVENTER IN COLD WATER MAIN IF NOT EXISTING PER LOCAL CODE LENEXA,KS 66214 REQUIREMENT. TEL 913 742 5000 FAX 913 742 5001 ANNOTATION i i T,` 101 ,m 0 i __ www.hei-eng.com < ` O 20. PLUMBING SYSTEMS WILL BE COMMISSIONED PER THE REQUIREMENTS OF THE ,' `� O PLUMBING PLAN NOTE CALLOUT I I E�+— E _+— > I COMMISSIONING SPECIFICATIONS DESCRIBED ON THE LEED PROTOTYPE GREEN 1550003152 I ,' --- __ SPECIFICATIONS. [E] 11 PLUMBING EQUIPMENT DESIGNATION. (CONTRACTOR FURNISHED I , O AND INSTALLED). REFER TO PLUMBING FIXTURE OR EQUIPMENT I -------- I 21. PRIOR TO COMMENCING WORK ON THE STORE, THE GENERAL CONTRACTOR Job Name and Number. 2015-0131 SCHEDULES i I i I SHALL PROVIDE COPIES OF THE COMMISSIONING SPECIFICATIONS ON THE LEED CU MECHANICAL EQUIPMENT DESIGNATION (CONTRACTOR FURNISHED i PROTOTYPE GREEN SPECIFICATIONS TO THE MECHANICAL, ELECTRICAL, Proposed AND INSTALLED UNLESS NOTED OTHERWISE) PLUMBING, AND CONTROLS SUB—CONTRACTORS. p CONNECTION POINT OF NEW WORK TO EXISTING I I VERIZON 1 DETAIL REFERENCE UPPER NUMBER INDICATES DETAIL NUMBER i ``� 0 _____------ �', ; PLUMBING PLAN NOTES: M1 LOWER NUMBER INDICATES SHEET NUMBER STO R E ° �� � , �\ ° i O LOCATION TO MINIMUM 1" EXISTING DOMESTIC WATER. FIELD VERIFY EXACT STANDARD MOUNTING HEIGHTS I (LEED) I CONNECT TO MINIMUM 4" EXISTING SANITARY. FIELD VERIFY EXACT PLUMBING (AFF, AFG, UNLESS NOTED OTHERWISE) / I LOCATION, SIZE, INVERT AND FLOW DIRECTION. PROVIDE FLOOR CLEANOUT (FCO) AS REQUIRED BY LOCAL CODE. REFER TO THE ARCHITECTURAL DRAWINGS FOR PLUMBING FIXTURE MOUNTING HEIGHTS. CONNECT TO MINIMUM 2" EXISTING PLUMBING VENT. FIELD VERIFY EXACT LINO, INSTALL PLUMBING FIXTURES WITH THE MOUNTING HEIGHTS AS LISTED BELOW ��\ ,' ` ��� LOCATION. CONTRACTOR SHALL RELOCATE PLUMBING VENT DISCHARGE AS WITH FINAL APPROVAL BY THE ARCHITECT. I `� ,� , \ \� ,' I REQUIRED TO ACCOMMODATE MINIMUM 15'-0" CLEARANCE FROM ALL 1obAddr= OUTSIDE AIR INTAKES AND 2'-0" FROM OTHER EQUIPMENT.] Washington Square Mall ADA ACCESSIBLE DRINKING FOUNTAIN 17" FLOOR TO RIM ADA ACCESSIBLE LAVATORIES 34" FLOOR TO RIM i �> `� l� i O ROUTE 3/4"CD FROM CRU-1 CONDENSATE PUMP DOWN IN WALL TO VALVE 9585 S.W. Washington ADA ACCESSIBLE WATER CLOSET 17" TO 19" FLOOR TO DRAIN BOX. SLOPE 1/8" PER FOOT MINIMUM. MOUNT VDB 12" ABOVE q FINISHED FLOOR. Scare Road I '"— 3 TOP OF SEATortland 5 VERIFY THE EXISTENCE OF SUB WATER METER. IF SUB METER IS NOT EXISTING, P , OR 97223 o ADA ACCESSIBLE WATER COOLER 35" FLOOR TO RIM O PROVIDE NEW, LABELED SUB METER AS SCHEDULED. Space R05-R07 N ADULT STANDARD DRINKING FOUNTAIN 40" FLOOR TO RIM LO ADULT STANDARD WATER COOLER 30" FLOOR TO RIM O VERIFY THE EXISTENCE OF LABELED, MAIN SHUTOFF VALVE. IF SHUTOFF o JANITOR'S SINK FAUCET FITTINGS 42" FLOOR TO CENTERLINE I I VALVE IS EXISTING BUT NOT LABELED, PROVIDE LABEL. IF SHUTOFF IS NOT tkawir�giltle EXISTING, NEW E AT EYE IN OFF 10 LAVATORY OR SINK 31" FLOOR TO RIM EMPLOYEE PROVIDE REO TIROOM BSE NDE ACDCESS TPANEL. PR FESS ONALESIGN OR PLUMBING PLAN cc I-, WASHING MACHINE OUTLET BOXES 42" FLOOR TO RIM STICKER ACCEPTABLE — NO LABEL MAKERS. COORDINATE LOCATION WITH cc � LANDLORD. WATER CLOSET 15" FLOOR TO RIM — — — — — — — — — — — — — — — a` j O CONNECT CONDENSATE LINE FROM FAN COIL UNITS TO CONDENSATE DRAIN BOX. o ABBREVIATIONS N0 AFF ABOVE FINISHED FLOOR MH MANHOLE ------------------------------------------ ----------------------------------------- m AFG ABOVE FINISHED GRADE MIN MINIMUM - - - - - - - - - - - - - - - - - - - - - - - - - - --- — -- -------- — — — — ----------- — — — — ---' - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Drawn By: North I AHU AIR HANDLING UNIT N/C NORMALLY CLOSED '�0W' M Q� BFF BELOW FINISHED FLOOR N/O NORMALLY OPEN Che&ed4 C9 BFG BELOW FINISHED GRADE ORD OVERFLOW ROOF DRAIN 0 ~ BOP BOTTOM OF PIPE PDI PLUMBING DRAINAGE INSTITUTE Date For n0 I BOS BOTTOM OF STRUCTURE PVC POLYVINYL CHLORIDE Client,12f24J2015 BTU BRITISH THERMAL UNIT PRV PRESSURE REDUCING VALVE Landlord; UQ4/2Oi5 a j CPUC CHLORINATED POLYVINYL RD ROOF DRAIN N Permit; 2 CHLORIDE RPM REVOLUTIONS PER MINUTE o DN DOWN RTU ROOFTOP UNIT P LU�JB I N GPLAN Bid: o ' Construction: DS DOWNSPOUT SF SQUARE FEET, SUPPLY FAN ss s saETR EXISTING TO REMAIN SP SUMP PUMP SCALE /4 =1 —0 Mon Issue: 2 EWC ELECTRIC WATER COOLER SS STAINLESS STEEL, SANITARY No. Date DescrkRion a FD FLOOR DRAIN 'o 3 SEWER, SOIL STACK FFA FROM FLOOR ABOVE TDH TOTAL DYNAMIC HEAD O FFB FROM FLOOR BELOW TFA TO FLOOR ABOVE i FF FINISHED FLOOR TFB TO FLOOR BELOW cc FL FLOW LINE TYP TYPICAL FLA FULL LOAD AMPS UL UNDERWRITERS LABORATORIES, M FLR FLOOR INC. N p GPM GALLONS PER MINUTE LINO UNLESS NOTED OTHERWISE c ° LO HD HEAD, HUB DRAIN V VOLT(S) rn w IE INVERT ELEVATION VS VENT STACK ZO IN WC INCHES OF WATER COLUMN VTR VENT THROUGH ROOF N JB JUNCTION BOX W/ WITH j J—BOX JUNCTION BOX W/O WITHOUT kW KILOWATT WC WATER COLUMN fV MAX MAXIMUM o I WS WASTE STACK C:1 j MBH 1000 BTU PER HOUR LEE N CLARITY m � c JDrawingNumber: O ? � a PLUMBING CODE: 2014 OREGON PLUMBING Z SPECIALTY CODE (2009 UPC) 15 OF 31 OWNER/TENANT: q& GODIVA Choco[atier GODIVA CHOCOLATIER, INC. 333 WEST 34TH STREET NEW YORK, NY 10001 00 PROJECT PLANNER: 5/8" G.W.S. OVER METAL FRAMING / O WJCA INC. 763 SUSQUEHANNA AVE. FRANKLIN LAKES, NJ 07417 TEL: 201-848-9060 FAX: 201-848-9881 ARCHITECT: 2'-2 5/8" DAVID A. UDKOW BREAK METAL OVER I/2" F.R.T PLYWOOp 11881 NORTH 113TH WAY 4-J SCOTTSDALE, AZ 85259 ^+ LEASE LINE Szi I/2" TEMP. CLEAR GLAZING X 0 U LIC. #: 2182 0 EXP. DATE: 6/30/16 GODIVA :3 Chocolatier 4 PLAN SECTION SCALE: 3" = 1 -o STORE NO: � 524 > PROJECT LOCATION: 41/2" le 2" GLAZING SYSTEM WASHINGTON SQ. MALL SPACE B04 0) FRAMING 9585 SW WASHINGTON Lo SQUAREROAD N PORTLAND, OR 90703 Lo L' - LEASE LINE 00 v In ISSUE DATE: Q NO. DATE DESCRIPTION 12-11-15 ISSUED FOR BID, W PERMIT AND LANDLORD Q REVIEW V` I�zl 5/8" G.W.B. OVER METAL FRAMING Fd 0 1/2" TEMP. CLEAR R NON-COMBUSTABLE U GLAZING %� BLOCKING AS REQUIRED 5/8" G.W.B. OVER U) NON-CON5USTA5LE METAL FRAMING BLOCKING AS REQUIRED 5 7/8" /3/,3/4" X 3/4" METAL >. m STOREFRONT REVEAL PTD. BLACK GLASS DOOR GLAZING SYSTEM EXISTING NEUTRAL PIER FRAMING >� 4-JL n ry 0 GLAZING SYSTEM FRAMING •C'�, v htt� co DA GLAZING 41/2"4 1/2 Q DAVID 2.82DKOW �f 2 a L SCOTTSDALE, AZ LEASE LINE00 6. O 1/2" TEMP. CLEAR GLAZING MT-1 BRAKE METAL OVER I/2" F.RT PLYWOOD (3) 3 5/8° T GLAZING SYSTEM MTL STUD POST. (TYP) FRAMING DRAWING TITLE: co MT-1 DRAKE METAL OVER 1/2" TEMP. CLEAR STOREFRONT r MTL STUD POST. DETAILS(3) 3 5/8" GLAZING DETAILS T N _N 0 LA Q CNil PROJECT NO: 41/2" X 41/2" 154129 Q CORNER POST DRAWING NO: Q LEASE LINE LEASE LINE 2"1 10 40 A202 Q 3 PLAN SECTION SCALE: 3" = V-0" 2 PLAN SECTION SCALE: 3" = 1'-0" 1 PLAN SECTION SCALE: 3" = V-0" Q PLUMBING FIXTURE SCHEDULE: INSTANTANEOUS GRUSKIN FIXTURES IN THIS SCHEDULE OR THEIR APPROVED EQUIVALENT ARE PROVIDED ELECTRIC WATER BY THE PLUMBING CONTRACTOR. SUBMIT SHOP DRAWINGS ON EACH OF HEATER MOUNTED WALL HUNG LAVATORY THESE ITEMS. REFER TO SPECIFICATIONS FOR FURTHER INFORMATION AND TO WALL. REFER TO SECURE PIPE HANGER INSTALLATION REQUIREMENTS. VERIFY ROUGH—IN REQUIREMENTS WITH SPECIFICATIONS FLEXIBLE RISERS TO 294 Morris Avenue Springfield,TO STRUCTURE N 07081 AND SCHEDULE REFER TO SPECIFICATIONS1 MANUFACTURER'S INSTALLATION INSTRUCTIONS AND INSTALL PER O O LAVATORY FAUCET FOR CONNECTIONS Tel: 973.376.4411 Fax:973.376.89$9 MANUFACTURER'S RECOMMENDATIONS. REFER TO THE ARCHITECTURAL www.GruskinGroup.com NJREGOIOD-9669-14 DRAWINGS FOR THE PLUMBING FIXTURE MOUNTING HEIGHTS. ANGLE STOP VALVE ON CDB CONDENSATE DRAIN BOX: GUY GRAY MODEL PL20OLV, HIGH COLD WATER SUPPLY— This document and the ideas and designs incorporated # DUAL OUTLET TYPE herein,as an Instrument of professional service, is the IMPACT POLYSTYRENE BOX AND FACEPLATE, WITHOUT WATER SUPPLIES AND THREADED STEEL ROD property of GRUSKIN ARCHITECTURE+DESIGN,P.C.,and VALVES, AND 2" BOTTOM OUTLET DRAIN. O WITH NUT AND WASHER is not to be used inwhdeorinpart for any other project TRIM: 24" LONG TAIL PIECE AND 2" DIAMETER P—TRAP. BOTH SIDES without the written aulhorizatlon of GRUSKIN HOT WATER SUPPLY &—a REFER TO SPECIFICATIONS ARCHITECTURE+DESIGN,P.C. EWH1 WATER HEATER: EEMAX # SP3208, INSTANTANEOUS, Ni CHROME TO LAVATORY IN FOR ROD SIZE All Rights Reserved REPLACEABLE CARTRIDGE TYPE HEATING ELEMENT, 3.0 KW INPUT, GLASS ADJACENT TOILET ©2015GruskinArchitecture+Design,P.C. REINFORCED BODY, WHITE ABS COVER, 3/8" COMPRESSION INLET AND OUTLET, ROOM IF SHOWN ON CLEVIS HANGER, SHOWN FOR CLARITY i( A, ( MA GPM FLOW RESTRICTOR, AND 0.5 GALLONS PER MINUTE AT A 40 DEGREE PLAN TEMPERATURE RISE. REFER TO SPECIFICATIONS FOR ELECTRICAL REQUIREMENTS: 208 VOLT SINGLE PHASE, 14.4 FULL DISCONNECT OTHER HANGER TYPES FOR PIPE AL 131 MT 2537 LOAD AMPS. FINISHED FLOOR SWITCH IS SERVED & SPACING AK NC 9961 3 1 SPECIFIED AR 38111 ND 1666 BY ELEC AZ 39209 NE A-3547 EWH2 WATER HEATER: EEMAX # SP4208, INSTANTANEOUS, Ni CHROME CA C-29898 NH 2796 PROVIDE FOR INSULATED PIPING REPLACEABLE CARTRIDGE TYPE HEATING ELEMENT, 4.1 KW INPUT, GLASS CO ARC-400347 NJ AI 09999 AT EACH HANGER A SECTION OF REINFORCED BODY, WHITE ABS COVER, 3/8" COMPRESSION INLET AND OUTLET, HIGH DENSITY INSULATION OR CT 9613 NM 004168 0.5 GPM FLOW RESTRICTOR, AND 0.5 GALLONS PER MINUTE AT A 56 DEGREE a ° ° a DC ARC100723 NV 5521 TEMPERATURE RISE. I 'e, °� STYROFOAM BILLETS DE 0006261 NY 025528-1 NY REFER TO SPECIFICATIONS FOR FL AR91629 OK a4895 ELECTRICAL REQUIREMENTS: 208 VOLT SINGLE PHASE, 19.7 FULL REFER TO SPECIFICATIONS, SCHEDULES, AND NOTES FOR MORE INFORMATION. MORE INFORMATION GA RA011075 OH 13761 LOAD AMPS. PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD ...._. HI AR 11489 _9R999 CONDITIONS. VERIFY CONNECTION SIZES AND LOCATIONS PER MANUFACTURER'S IA 05713 PA RA—015432—B FD FLOOR DRAIN: JAY R .SMITH # 2005L (—A), CAST IRON BODY AND REQUIREMENTS, AND INSTALL PER MANUFACTURER'S INSTRUCTIONS. REFER TO ID AR-984459 PR 19965 CLAMPING COLLAR, ADJUSTABLE 6" ROUND NICKEL BRONZE STRAINER. USE FLOOR PLANS FOR PIPE SIZES. INSTALL WATER HEATER CLEAR OF ADA PROVIDE INSULATION SHIELD IL 001-019152 RI 2666 PUSH—ON JOINT OF OUTLET SIZE AS SHOWN ON PLANS. REQUIRED SPACE FOR ADA COMPLIANT LAVATORY OR SINK. PROVIDE T&P FOR INSULATED PIPE IN AR10400066 SC 6834 KS 4674 SD 11532 RELIEF VALVE ON WATER HEATER OUTLET ONLY IF REQUIRED BY LOCAL KY 5967 TN 101374 SINK1 LAVATORY DECLYN A 19" X 17' RECTANGULAR WALL MOUNTED BLE) AMERICAN AUTHORITIES, AND DISCHARGE WERE DIRECTED BY AUTHORITIES. P I P E HANGER D ETA I L LA 5734 TX 17680 STANDARD # 0321 026 1 ME ARC 2596 UT 5881358-0301 WHITE VITREOUS CHINA FIXTURE WITH FAUCET LEDGE, REAR OVERFLOW AND NO SCALE MD 11016 VT 2572 WALL FAUCET: GER. MA 10635 VA 0401 CHICAGOFAUCET # 802—V665ABCP — 4" LEAD FREE INSTANTANEOUS WATER HEATER MI 130 052379 WA 0344 11223 CENTERSET FAUCET WITH #665 PUSH BUTTON METERING CARTRIDGE (:2 ) MN 44326 WI 9900-005 HANDLES, VANDAL RESISTANT, 12 SECOND CYCLE DURATION, AND # E2805 0.5 NO SCALE MO 386005029740 WV 3727 C-1 GPM AERATOR. MS 3860 WY C-1967 TRIM: McGUIRE # 155WC GRID DRAIN WITH OFFSET TAILPIECE, Professionaiseal: NIBCO 7145A—LF LEAD FREE QUARTER TURN BALL COMPRESSION LOOSE KEY TYPE ANGLE STOP VALVES WITH 3/8" CHROME PLATED COPPER RISERS AND ESCUTCHEONS, McGUIRE # 8872CF 1-1/4" 17 GAUGE TUBULAR CHROME PLATED BRASS ADJUSTABLE P—TRAP AND WASTE ARM WITH CLEANOUT PLUG C^S� ��GINE�R`rS�� AND ESCUTCHEON, CONCEALED ARM CARRIER WITH STANCHIONS TO FLOOR, c� TRUEBRO "HANDI LAV—GUARD" # 103 INSULATION KIT FOR WATER AND WASTE 84242PE 9 PIPES. SINK2 SINK (ADA ACCESSIBLE) JUST # SL—ADA-1921—A—GR, 19" x 21" x 5-1/2" DEEP, SINGLE COMPARTMENT, SELF—RIMMING, 18 GAUGE TYPE 304 STAINLESS O E STEEL, FIXTURE WITH FAUCET LEDGE. SET IN BED OF PUTTY. PROVIDE DRAIN y OPENING ON RIGHT SIDE. FAUCET: JUST # J-900 8" CENTERSET LEAD—FREE FAUCET WITH SINGLE LEVER HANDLE AND 1.0 GPM AERATOR. TRIM: NIBCO 7145A—LF LEAD FREE QUARTER TURN BALL ti'`l > EXP ES: 1?J COMPRESSION LEVER HANDLE TYPE ANGLE STOP VALVES WITH 3/8" CHROME I PLATED COPPER RISERS AND ESCUTCHEONS, McGUIRE # 151M CUP STRAINER l WCO COfisuftant WITH 1-1/2" 17 GAUGE TAILPIECE, McGUIRE # 8912—C—F 1-1/2" 17 GAUGE ? TUBULAR CHROME PLATED BRASS ADJUSTABLE P—TRAP WITH BRASS CLEANOUT "S AND ESCUTCHEON. TP TRAP PRIMER: PRECISION PLUMBING PRODUCTS # PR-500 "PRIME HENDERSON RITE", CORROSION RESISTANT BRASS BODY, "0" RING SEALS, 1/2" INLET AND > Y WC1 2 ENGINEERSM OUTLET, AND INTEGRAL VACUUM BREAKER. INSTALL TRAP PRIMER ATA WCO N l/ L rxi MINIMUM OF 12" ABOVE FINISHED FLOOR. PROVIDE WITH DISTRIBUTION # 2'1, `V 8345LENEXADRIVE,SUfTE300 DU-2 FOR TWO, # DU-3 FOR THREE, OR # DU-4 FOR FOUR DRAIN CONNECTIONS. SINK1 SINK1 LENEXA,KS 66214 SINK2 TEL 913 742 5000 Fax 913 742 5001 CK) VALVE BOX: GUY GRAY MODEL # BIM875, 20 GAUGE STEEL BOX, 18 ti`l 2 W � S 3"W FD www.hei-eng.com GAUGE STEEL FACEPLATE, BOTTOM INLET WATER SUPPLY WITH 1/2" x 1/4" 1550003152 COMPRESSION ANGLE STOP VALVE. MOUNT AT 12" AFF. Y TRIM: LOOP 4 FEET OF 1/4" TYPE "K" SOFT COPPER TUBING. ? ` D \ WC1 FLOOR—MOUNTED WATER CLOSET (ADA ACCESSIBLE): MANSFIELD # `V 2"W /JkS� kb Name and Number. 2015.4131 148-153 TANK TYPE WHITE VITREOUS CHINA FIXTURE WITH ELONGATED BOWL, \ 3»W \2 1.0 GALLON PER FLUSH, AND PRESSURE ASSISTED FLUSHMATE ACTION ANDC14 Proposed LEFT OR RIGHT HAND TRIP LEVER. INSTALL TRIP LEVER ON THE WIDE SIDE OF 2 h% THE STALL. MEETS DEFINITION FOR HIGH EFFICIENCY TOILET (HET). JkS \� CDB TRIM: CHURCH # 950OSSC WHITE OPEN—FRONT CONTOURED, SOLID o VE R I ZO N PLASTIC, HEAVY DUTY, SEAT LESS COVER WTH SELF—SUSTAINING CHECK HINGES WCO FD AND STAINLESS STEEL BOLTS, McGUIRE 2166CC ANGLE STOP VALVE WITH STORE RISER AND CHROME—PLATED ESCUTCHEON. r WHA WATER HAMMER ARRESTER: PRECISION PLUMBING PRODUCTS, �\INS WC1 HARD DRAWN COPPER BODY WITH WROUGHT COPPER FITTINGS, PISTON TYPE (LEED) WITH LUBRICATED EPDM "0" RING SEALS, ASSE 1010 CERTIFICATION. PROVIDE PDI SIZES "A" THROUGH "F" AS SHOWN ON PLANS. PROVIDE SIZE "A" UNLESS 4"S SHOWN OTHERWISE ON THE PLANS. WCO WALL CLEANOUT: J.R.SMITH # 4530 SERIES CLEANOUT TEE AND STAINLESS STEEL COVER WITH IRON PLUG AND GASKET SEAL. REFER TO SPECIFICATIONS FOR INSTALLATION. Job Address: WM IF NOT EXISTING: (:3ANO ASTE & VENT RISER DIAGRAM Washington Square Mall WATER METER: BADGER METER # 55 1", LEAD FREE BRONZE SCALE 9585 S.W. Washington MAINCASE AND MEASURING CHAMBER, BOTTOM PLATE, STAINLESS STEEL Square Road TRIM AND BOLTS, THERMOPLASTIC STRAINER, OSCILLATING PISTON Portland OR 97223 MEASURING ELEMENT, STRAIGHT READING HERMETICALLY SEALED REGISTER, r o REGISTRATION IN US GALLONS, MAGNETIC DRIVE, AND COMPLIANCE WITH Space R05-R07 N ANSI / AWWA C700. PROVIDE WITH REMOTE READING SYSTEM IF / AS a_ � REQUIRED. r j DrawbrgMe: O LO PLUMBING DETAILS coca 2 AND SCHEDULES a` j :fo a o N UJ N O 1 Drawn By: Nonh Arrow. N Q FIXTURE BRANCH CONNECTION SCHEDULE Checked Br. 0 N C9 r FIXTURE COLD WATER HOT WATER WASTE VENT 0I Date Issued For LLJ Landlord; 12/24/2015 WATER CLOSET (TANK) 1/2" — 4" 2" lent 12,424/2015a a ? LAVATORY/ HAND SINK 1/2" 1/2" 2" 2" SINK 1/2" 1/2" 2" 2" Permit; 12/24/2015 cli 12 (nco Bid: C o DRAIN BOX — — 2" 2" Construction: r O FLOOR DRAIN — — 2" 2" Revislon Issue: Z Na. Date Desaiptlm NOTE: 0 3 PIPE SIZES SHOWN ARE MINIMUM. � I 0 -o _m ~ N m u7 C M Cr O O c O o LO c LO r % Z N ix N o N o L0 rn � N WQ Drawing Number: > =r O N a_ P2 E W N (L 16 OF 31 SECTION 15B: PLUMBING: 156 1 GENERAL INSTRUCTIONS THE TERMS APPROVED", "APPROVED EQUAL", OR "EQUAL", REFER TO APPROVAL BY THE PROVIDE SLEEVES FOR HORIZONTAL PIPE PASSING THROUGH OR UNDER FOUNDATION. INTERIOR WASTE AND VENT ABOVE SLAB: WASTE AND VENT PIPE ABOVE SLAB INSIDE ABOVE GROUND INSTALLATION FOR SOIL AND WASTE: INSTALL SOIL AND WASTE PIPING TO PROVIDE FAUCETS AS SCHEDULED ON DRAWINGS: BY CHICAGO, SPEAKMEN, ZURN, OR T&S ENGINEER AS AN ACCEPTABLE ALTERNATE BID. NO SUBSTITUTIONS WILL BE CONSIDERED SLEEVES SHALL BE CAST IRON SOIL PIPE TWO NOMINAL PIPE SIZES LARGER THAN THE PIPE BUILDING SHALL BE HUBLESS CAST IRON SOIL PIPE AND FITTINGS, MEETING ASTM A888 AND A UNIFORM SLOPE OF NOT LESS THAN 1/8" PER FOOT FOR PIPING 4" OR LARGER, AND NOT BRASS. GENERAL REQUIREMENTS THAT ARE NOT BID AS AN ALTERNATE. NO MATERIAL SUBSTITUTIONS SHALL BE CONSIDERED SERVED. CISPI 301, MANUFACTURED BY AB & I FOUNDRY, CHARLOTTE OR TYLER PIPE AND BEARING LESS THAN 1/4" PER FOOT FOR PIPING 3" OR SMALLER. LAY PIPE AT UNIFORM SLOPE FREE FOR APPROVAL PRIOR TO AWARD OF CONTRACT. THE TRADEMARK OF THE CISPI AND NSF. PVC SCHEDULE 40 DWV ASTM D2665 PIPE WITH PVC FROM SAGS. SUPPORT PIPE WITHIN 12" OF EACH JOINT. MAKE CHANGES IN DIRECTION PROVIDE SINGLE LEVER HANDLE FAUCETS AS SCHEDULED ON DRAWINGS: BY CHICAGO, JUST, REQUIREMENTS UNDER DIVISION ONE AND THE GENERAL AND SUPPLEMENTARY CONDITIONS PROVIDE SCHEDULE 40 PVC PIPE SLEEVES FOR VERTICAL PRESSURE PIPE PASSING THROUGH MEETING ASTM B1784, "SOLID WALL" CELL CLASS 12454-B WITH ASTM 2665 SOCKET FROM HORIZONTAL TO VERTICAL, AT FIXTURE BRANCHES AND OTHER BRANCH CONNECTIONS KOHLER, SPEAKMEN, OR SYMMONS OF THESE SPECIFICATIONS SHALL BE A PART OF THIS SECTION. THE CONTRACTOR SHALL BE COORDINATE AND VERIFY WITH OTHER TRADES WHETHER OR NOT THE SUBSTITUTED CONCRETE SLAB ON GRADE. SLEEVES SHALL BE ONE NOMINAL PIPE SIZE LARGER THAN THE FITTINGS WITH SOLVENT WELD JOINTS IS ALSO PERMITTED WHERE APPROVED BY CODE. WITH SANITARY 'TEES" OR SHORT SWEEP "ELLS". MAKE CHANGES IN DIRECTION FROM RESPONSIBLE TO BECOME THOROUGHLY ACQUAINTED WITH ITS CONTENTS AS TO EQUIPMENT CAN BE INSTALLED AS SHOWN ON THE CONSTRUCTION DRAWINGS WITHOUT PIPE SERVED AND TWO PIPE SIZES LARGER THAN PIPE SERVED FOR DUCTILE IRON PIPES WITH VERTICAL TO HORIZONTAL OR HORIZONTAL TO HORIZONTAL WITH LONG RADIUS FITTINGS, FIXTURE P-TRAPS SHALL BE 17 GAUGE BRASS BODY WITH CLEANOUT, 17 GAUGE SEAMLESS REQUIREMENTS THAT AFFECT THIS DIVISION OR SECTION. WORK REQUIRED UNDER THIS MODIFICATION TO ASSOCIATED SYSTEMS OR ARCHITECTURAL OR ENGINEERING DESIGN. RESTRAINING RODS. SEAL WATER-TIGHT WITH SILICONE CAULK. CONNECTIONS TO PLUMBING FIXTURES AND EQUIPMENT: 1-1/4" AND LARGER WASTE LONG SWEEPING "ELLS", COMBINATION 'Y AND 1/8 BEND" FITTINGS, OR 45 DEGREE "ELLS" TUBULAR WALL BEND WITH CAST BRASS SLIP NUT, SHALLOW STEEL FLANGE, ALL CHROME SECTION INCLUDES MATERIAL, EQUIPMENT, APPLIANCES, TRANSPORTATION, SERVICES AND INCLUDE ADDITIONAL COSTS FOR ARCHITECTURAL AND ENGINEERING DESIGN FEES IN BID IF CONNECTIONS FROM FIXTURE TRAPS TO CAST IRON PIPE SHALL BE "DWV" COPPER WITH (1/8 BEND FITTINGS), 1/6 BEND OR 1/16 BEND AND 'Y" FITTINGS. PROVIDE A SMOOTH AND PLATED: BY MCGUIRE, BRASS CRAFT, DEARBORN BRASS, EBC, PROFLO, WATTS BRASS AND LABOR REQUIRED TO COMPLETE THE ENTIRE PLUMBING SYSTEM AS REQUIRED BY THE DRAWING MODIFICATIONS ARE REQUIRED BECAUSE OF SUBSTITUTED EQUIPMENT. PROVIDE 1/2" THICK CELLULAR FOAM INSULATION AROUND PERIMETER OF NON-PRESSURE WROUGHT COPPER DRAINAGE PATTERN FITTINGS WITH COPPER SWEAT OR COMPRESSION UNIFORM INVERT IN THE SYSTEM. DRILLING OR TAPPING OF SOIL AND WASTE LINES, AND TUBULAR, OR ZURN. DRAWINGS AND SPECIFICATIONS. PIPE PASSING THRU CONCRETE SLAB ON GRADE. INSULATION SHALL EXTEND TO 2" ABOVE JOINTS AT FIXTURE TRAP CONNECTIONS AND THREADED JOINTS AT CONNECTIONS TO CAST SADDLE HUBS AND BANDS ARE NOT PERMITTED. LOCATE AND INSTALL SOIL AND WASTE ELECTRONIC DRAWINGS AND BELOW THE CONCRETE SLAB. IRON PIPE. LINES AS INDICATED ON THE DRAWINGS. DETERMINE EXACT LOCATIONS IN SUCH A MANNER LAVATORY, SINK, AND WATER CLOSET SUPPLIES SHALL BE SOLID BRASS ANGLE OR STRAIGHT THE SPECIFICATIONS AND THE DRAWINGS ARE COMPLEMENTARY, AND ANY PORTION OF AS TO MAINTAIN PROPER CLEARANCE. TYPE WITH FULL TURN BRASS STEM, WHEEL HANDLE OR LOOSE KEY TYPES AS NOTED ON WORK DESCRIBED IN ONE SHALL BE PROVIDED AS IF DESCRIBED IN BOTH. IN THE EVENT OF IN PREPARATION OF SHOP OR RECORD DRAWINGS, CONTRACTOR MAY, AT HIS OPTION, ELECTRICAL WIRING INDIRECT AND CONDENSATE DRAIN INSIDE BUILDING: INDIRECT AND CONDENSATE DRAIN DRAWINGS, SHALLOW STEEL FLANGE, 3/8" COPPER RISER FLANGE, ALL CHROME PLATED, 294 Morris Avenue Springfield,NJ 07081 DISCREPANCIES ON THE DRAWINGS AND SPECIFICATIONS, THE CONTRACTOR SHALL NOTIFY OBTAIN ELECTRONIC DRAWING FILES IN AUTOCAD OR DXF FORMAT FROM THE ENGINEER PIPE INSTALLED INSIDE THE BUILDING SHALL BE TYPE "M" HARD COPPER WITH WROUGHT PLUMBING VENT: CONNECT PLUMBING VENT PIPES TO FIXTURE DRAIN PIPES AS INDICATED FINAL CONNECTION AS REQUIRED: BY MCGUIRE, BRASS CRAFT, EBC, PROFLO, OR ZURN. Tel: 973.376.4411 Fax:973.376.8989 THE ENGINEER OF SAME PRIOR TO PROCEEDING WITH THE WORK INVOLVED, IN ORDER THAT FOR A SHIPPING AND HANDLING FEE OF $200 FOR A DRAWING SET UP TO 12 SHEETS AND $15 LINE VOLTAGE WIRING SHALL BE PROVIDED BY DIVISION 16. LINE VOLTAGE CONTROL AND COPPER FITTINGS FOR 1" AND SMALLER AND "DWV" COPPER WITH WROUGHT COPPER ON THE DRAWINGS OR AS REQUIRED BY THE INSTALLATION PRACTICES ADOPTED AND www.GruskinGroup.com NIREG0100-9869-14 CORRECT PROGRESS OF THE WORK MAY BE PERFORMED. PER SHEET FOR EACH ADDITIONAL SHEET. CONTRACTOR SHALL CONTACT THE ARCHITECT INTERLOCK WIRING FOR PLUMBING SYSTEMS SHALL ALSO BE PROVIDED BY DIVISION 16 DRAINAGE PATTERN FITTINGS FOR 1-1/4" AND LARGER HARD TEMPER COPPER TUBE AND ENFORCED BY LOCAL CODES OFFICIAL, AND EXTEND VENT PIPES FULL SIZE TO EXISTING VENT LAVATORY DRAINS SHALL BE GRID TYPE CHROME PLATED 17 GAUGE BRASS OPEN GRID WITH FOR WRITTEN AUTHORIZATION. CONTRACTOR SHALL COMPLETE AND SEND THE FORM CONTRACTOR. LOW VOLTAGE CONTROL WIRING SHALL BE PROVIDED BY THE DIVISION 15 SOLDERED CONNECTIONS MADE WITH 95/5 SOLDER. INSTALL CLEANOUTS AT ELBOWS GRADE PIPE TO A UNIFORM SLOPE SO AS TO DRAIN BACK BY GRAVITY TO THE DRAINAGE 1-1/4" X 6" LONG SEAMLESS BRASS TAILPIECE AND BRASS LOCKNUT WITH HEAVY RUBBER DEFINITIONS ATTACHED AT THE END OF THIS SECTION ALONG WITH A CHECK MADE PAYABLE TO CONTRACTOR. FURNISH WIRING DIAGRAMS TO THE DIVISION 16 CONTRACTOR AS REQUIRED GREATER THAN 45 DEGREES. PIPING SYSTEM. APPLY WHITE LEAD PIPE DOPE ON MALE STEEL PIPE THREADS. VENT LINES BASIN WASHER AND FIBER FRICTION WASHER, BY MCGUIRE, BRASS CRAFT, DEARBORN BRASS, Thisdocument and the ideas and designs incorporated HENDERSON ENGINEERS, INC. CONTRACTOR SHALL INDICATE THE DESIRED SHIPPING FOR PROPER EQUIPMENT HOOKUP. COORDINATE WITH THE DIVISION 16 CONTRACTOR THE SHALL BE AIR AND WATER TIGHT. VENT FLOOR DRAINS INDIVIDUALLY OR CONNECT THEM TO EBC, PROFLO, WATTS BRASS AND TUBULAR, OR ZURN. herein,as an instrument of professlonal service, Is the FURNISH: "TO SUPPLY AND DELIVER TO THE PROJECT SITE, READY FOR UNLOADING, METHOD AND DRAWING FORMAT ON THE ATTACHED FORM. IN ADDITION TO PAYMENT, ACTUAL WIRE SIZING AMPS FOR PLUMBING EQUIPMENT (FROM THE EQUIPMENT PIPING AND EQUIPMENT INSULATION A HORIZONTALLY VENTED LINE AS SHOWN ON THE DRAWINGS. propertyof GRUSKIN ARCHITECTURE+DESIGN,P.C.,and UNPACKING, ASSEMBLY, INSTALLATION AND SIMILAR OPERATIONS." ARCHITECT'S WRITTEN AUTHORIZATION AND ENGINEER'S RELEASE AGREEMENT FORM MUST NAMEPLATE) TO ENSURE PROPER INSTALLATION. SINK DRAINS SHALL BE BASKET TYPE WITH CHROME PLATED FORGED BRASS BASKET STRAINER 'snottobeusedinwholeorinpartforany other project BE RECEIVED BEFORE ELECTRONIC DRAWING FILES WILL BE SENT. DOMESTIC COLD WATER, HOT WATER, INDIRECT, AND CONDENSATE DRAIN PIPE (WITHIN DOMESTIC WATER: ARRANGE COLD AND HOT PIPING TO DRAIN AT THE LOWEST POINT IN AND STRAINER BODY WITH 1-1/2" X 4" LONG SEAMLESS BRASS TAILPIECE AND CAST BRASS without the writtenauthorlzatlonof GRUSKIN INSTALL: 'TO PERFORM ALL OPERATIONS AT THE PROJECT SITE INCLUDING, BUT NOT LIMITED EQUIPMENT FURNISHED BY OTHERS BUILDING) 1" ONE-PIECE FIBERGLASS COVERING WITH FIRE-RESISTANT JACKET WITH SELF- EACH SYSTEM. INSTALL AT LEAST ONE PIPE UNION ADJACENT TO ALL SHUTOFF VALVES, AT LOCK AND COUPLING NUTS BY MCGUIRE, BRASS CRAFT, DEARBORN BRASS, EBC, PROFLO OR ARCHITECTURE+DESIGN,P.C. TO, THE ACTUAL UNLOADING, UNPACKING, ASSEMBLING, ERECTING, PLACING, ANCHORING, OPERATION AND MAINTENANCE INSTRUCTIONS SEALING LAP TO PROVIDE A CONTINUOUS VAPOR BARRIER BY CERTAINTEED, OWENS- CONNECTION POINTS OF EACH PIECE OF EQUIPMENT, AND ELSEWHERE IN THE SYSTEM ZURN.. AllRiglitsReserved APPLYING, WORKING TO DIMENSION, FINISHING, CURING, PROTECTING, CLEANING, TESTING, FURNISH AND INSTALL ROUGHED-IN WASTES, VENTS AND WATER SERVICES. PROVIDE FINAL CORNING, OR ARMSTRONG. FOR HOT PIPING, PROVIDE PIPE HANGERS AND RISER CLAMPS WHERE REQUIRED TO ALLOW PROPER MAINTENANCE. PROVIDE UNIONS OF THE GROUND COMMISSIONING, STARTING UP AND SIMILAR OPERATIONS, COMPLETE, AND READY FOR THE DURING THE COURSE OF CONSTRUCTION, COLLECT AND COMPILE A COMPLETE BROCHURE CONNECTION TO KITCHEN EQUIPMENT, FURNISHED BY OTHERS, IN LOCATIONS AS INDICATED SIZED FOR THE OUTSIDE DIAMETER OF PIPING. BUTT INSULATION TO HANGER OR RISER JOINT TYPE. MAKE ALLOWANCE FOR EXPANSION AND CONTRACTION WHERE REQUIRED BY PROVIDE HANDICAP INSULATION KITS FOR LAVATORIES AND SINKS ON EXPOSED WATER AND ©2015GruskinArchitecture+Design,P.C. INTENDED USE. OF EQUIPMENT FURNISHED AND INSTALLED ON THIS PROJECT. INCLUDE OPERATIONAL AND ON THE DRAWINGS. PROVIDE ACCESSORY ITEMS THAT ARE REQUIRED BUT NOT FURNISHED CLAMP FOR VERTICAL PIPE. SEAL EXPOSED INSULATION WITH INSULATION SEALER. THE INSTALLATION. WHERE WATER PIPING OCCURS IN EXTERIOR WALLS, HOLD PIPE AS WASTE PIPES AND FITTINGS, INCLUDING OFFSET DRAIN AND CONTINUOUS WASTE COVERS MAINTENANCE INSTRUCTIONS, MANUFACTURER'S CATALOG SHEETS, WIRING DIAGRAMS, WITH THE EQUIPMENT, INCLUDING TRAPS, STOP VALVES, PRV'S, INDIRECT DRAIN FROM EXCEPTION FOR VERTICAL PIPING: PROVIDE CLAMPS SIZED FOR THE OUTSIDE DIAMETER OF CLOSE AS POSSIBLE TO THE INTERIOR FACE OF WALL AND INSTALL INSULATION BATT OR WHERE REQUIRED: BY BROCAR, MCGUIRE, PLUMBEREX "PRO-2000", PROFLO, TRAP-WRAP KWEIGM A, 1 AIA PROVIDE: 'TO FURNISH AND INSTALL, COMPLETE AND READY FOR THE INTENDED USE." PARTS LISTS, APPROVED SHOP DRAWINGS, AND DESCRIPTIVE LITERATURE AS FURNISHED BY EQUIPMENT TO FLOOR DRAINS, AND ACCESSORY ITEMS INDICATED OR REQUIRED FOR THE THE VERTICAL PIPE AND EXTEND CLAMP THROUGH INSULATION. SEAL PENETRATIONS OF OTHER INSULATION (MINIMUM R-8) BETWEEN PIPING AND THE EXTERIOR WALL FACE. OR TRU-BRO. THE EQUIPMENT MANUFACTURER. INCLUDE AN INSIDE COVER SHEET THAT LISTS THE PROPER OPERATION OF THE COMPLETE SYSTEM AT THE TERMINATION OF THE WORK. INSULATION AND VAPOR BARRIER WITH WET COAT OF VAPOR BARRIER IAP CEMENT. FOR AL 5421 WT 2537 FURNISHED BY OWNER OR FURNISHED BY OTHERS: AN ITEM FURNISHED BY THE OWNER OR PROJECT NAME, DATE, OWNER, ARCHITECT, CONSULTING ENGINEER, GENERAL CONTRACTOR, COLD PIPING AT HANGERS PROVIDE 8" LONG SECTIONS OF HIGH DENSITY, HIGH PIPING SANITIZATION WATER HEATER AK 13167 NC 9961 UNDER OTHER DIVISIONS OR CONTRACTS, AND INSTALLED UNDER THE REQUIREMENTS OF SUB-CONTRACTOR, AND AN INDEX OF CONTENTS. DIVISION 15 CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECT ROUGH-IN DIMENSIONS, TEMPERATURE CALCIUM SILICATE BY JOHNS-MANVILLE, FIBERGLASS BY KNAUF, OR 8" LONG THIS DIVISION, COMPLETE, AND READY FOR THE INTENDED USE, INCLUDING ALL ITEMS AND AND SHALL VERIFY SAME WITH ARCHITECT AND/OR EQUIPMENT SUPPLIER PRIOR TO SERVICE STYROFOAM BILLETS BY DOW OR FLEXIBLE UNICELLULAR PIPING INSULATION MEETING ASTM SANITIZE THE ENTIRE DOMESTIC WATER PIPING SYSTEM (COLD AND HOT) WITH A SOLUTION WATER HEATER SHALL BE BY A.O.SMITH, BRADFORD-WHITE, LOCHINVAR, STATE, RHEEM, OR AR 3811 ND 1666 SERVICES INCIDENTAL TO THE WORK NECESSARY FOR PROPER INSTALLATION AND SUBMIT THREE COPIES OF LITERATURE BOUND IN APPROVED BINDERS TO THE ARCHITECT AT INSTALLATIONS. C 534-01A, TYPE I WITH INTEGRAL HIGH DENSITY PIPE SUPPORTS AND ENCASED IN STEEL CONTAINING NOT LESS THAN 50 PPM AVAILABLE CHLORINE. KEEP SOLUTION IN THE SYSTEM RUUD WITH CAPACITY AS SCHEDULED ON THE DRAWINGS. UNIT SHALL BE ELECTRIC AZ 39209 NE A-3547 OPERATION. INCLUDE THE INSTALLATION UNDER THE WARRANTY REQUIRED BY THIS THE TERMINATION OF THE WORK. PAPER CLIPS, STAPLES, RUBBER BANDS, AND MAILING INSULATION SHIELD BY COOPER B-LINE / ARMACELL OR APPROVED EQUAL. INSULATION FOR A MINIMUM OF 24 HOURS, WITH EACH VALVE BEING OPERATED SEVERAL TIMES DURING GLASSLINED TANK TYPE COMPLETE WITH STEEL JACKET, FIBERGLASS INSULATION, CA C-29698 NH 2796 DIVISION." ENVELOPES ARE NOT CONSIDERED APPROVED BINDERS. FINAL APPROVAL OF MECHANICAL ALTERNATES SHALL BE CONTINUOUS ALONG THE PIPE SURFACE, EXCEPT AT VALVES, UNIONS, AND WHERE THE PERIOD. AFTER COMPLETION, FLUSH SYSTEM WITH CITY WATER UNTIL CHLORINE MAGNESIUM ANODE, INTEGRAL THERMOSTATS AND CONTROLS, AND TEMPERATURE & CO ARC-400347 NJ AI 09999 SYSTEMS INSTALLED UNDER THIS CONTRACT WILL BE WITHHELD UNTIL THIS EQUIPMENT PIPING IS EXPOSED AT FIXTURES. PROVIDE 1" FIBERGLASS INSULATION ON VENT PIPING RESIDUAL IS LOWERED TO INCOMING CIN WATER LEVEL. PRESSURE RELIEF VALVE. WATER HEATER SHALL BE UL LISTED AND MEET ASHRAE 90.1B CT 9613 NM 004168 ENGINEER: WHERE REFERENCED IN THIS DIVISION, "ENGINEER" IS THE ENGINEER OF RECORD BROCHURE IS RECEIVED AND DEEMED COMPLETE BY THE ARCHITECT AND ENGINEER. REFER TO THE ARCHITECTURAL PORTION OF THE SPECIFICATION FOR LIST OF ALTERNATES. WITHIN SIX FEET OF VENT THROUGH THE OF ROOF. PROVIDE FIBERGLASS INSULATION ON STANDARDS FOR THERMAL EFFICIENCY AND STANDBY HEAT LOSS. DC ARC100723 NV 5521 AND THE DESIGN PROFESSIONAL FOR THE WORK UNDER THIS DIVISION, AND IS A INSTRUCT WORKMEN TO SAVE REQUIRED LITERATURE SHIPPED WITH THE EQUIPMENT APPLICABLE SECTIONS OF THE BASE SPECIFICATIONS SHALL APPLY TO ALL WORK REQUIRED BY DOMESTIC COLD AND HOT WATER PIPES INSTALLED IN WALLS AND CHASES. PROVIDE PIPE AND VALVE MARKERS DE 0006261 NY 025528-1 NY CONSULTANT TO, AND AN AUTHORIZED REPRESENTATIVE OF, THE ARCHITECT, AS DEFINED IN ITSELF, FOR INCLUSION IN THIS BROCHURE. THE ALTERNATE UNLESS OTHERWISE SPECIFIED. DETERMINE WHETHER OR NOT AND HOW FIBERGLASS INSULATION ON DOMESTIC COLD AND HOT WATER PIPES INSTALLED IN WALLS RELIEF VALVE: WATER HEATER RELIEF VALVE SHALL BE OF THE TEST LEVER TYPE, WITH FL AR91629 OK a4895 THE GENERAL AND/OR SUPPLEMENTARY CONDITIONS. WHEN USED IN THIS DIVISION, IT EACH ALTERNATE AFFECTS WORK. INCLUDE LABOR, MATERIALS, EQUIPMENT AND AND CHASES. PROVIDE INSULATION PROTECTION SHIELD AT EACH HANGER FOR INSULATED PROVIDE PLASTIC LAMINATE OR BRASS VALVE TAG ON EVERY VALVE, COCK AND CONTROL AUTOMATIC RESET, COMBINATION TEMPERATURE AND PRESSURE RELIEF, APPROVED AND GA RA011075 OH 13761 MEANS INCREASED INVOLVEMENT BY, AND OBLIGATIONS TO, THE ENGINEER, IN ADDITION PROVIDE "AS-BUILT" DRAWINGS (SEE SPECIAL CONDITIONS). TRANSPORTATION SERVICES NECESSARY FOR AND INCIDENTAL TO THE COMPLETION OF PIPING. DEVICE IN EACH PLUMBING PIPING SYSTEM; EXCLUDE CHECK VALVES, VALVES WITHIN STAMPED BY THE AMERICAN GAS ASSOCIATION. IT SHALL BE INSTALLED DIRECTLY ON THE TO INVOLVEMENT BY, AND OBLIGATIONS T0, THE "ARCHITECT". WORK UNDER EACH PARTICULAR ALTERNATE. FURNISH SEPARATE BID FOR EACH ALTERNATE FACTORY-FABRICATED EQUIPMENT UNITS, PLUMBING FIXTURE FAUCETS, CONVENIENCE AND HEATER TANK, OR IN THE HOT WATER OUTLET, NOT MORE THAN 3" FROM THE TANK. THE HI AR 114$9 OR 4899 TRAINING APPLICABLE TO WORK, STATING THE AMOUNT TO BE ADDED OR DEDUCTED FROM THE BASE COVER FITTINGS WITH ZESTON, KNAUF, OR EQUAL ONE-PIECE PVC PREMOLDED INSULATING LAWN-WATERING HOSE BIBBS, AND SHUT-OFF VALVES AT PLUMBING FIXTURES AND SIMILAR TEMPERATURE SHALL BE NORMALLY SET TO RELIEVE AT 210'F AND THE PRESSURE RELIEF IA 05713 P A-01 2-9 AHJ: THE LOCAL CODE AND/OR INSPECTION AGENCY (AUTHORITY) HAVING JURISDICTION BID. COVERS. FITTING COVERS, JACKETS, AND ADHESIVES SHALL NOT EXCEED FLAME SPREAD ROUGH-IN CONNECTIONS OF END-USE FIXTURES AND UNITS. SHALL BE AT 125 PSI. THE RELIEF VALVE DISCHARGE LINE SHALL BE PIPED DOWN AND ID AR-984459 PR 19965 OVER THE WORK. AT A TIME MUTUALLY AGREED UPON BETWEEN THE OWNER AND CONTRACTOR, PROVIDE RATING OF 25 AND SMOKE DEVELOPMENT RATING OF 50 PER ASTM E84. AT ALL ELBOWS TERMINATE 6" ABOVE A FLOOR DRAIN. IL 001-01 9 1 52 RI 2666 THE SERVICES OF A FACTORY TRAINED AND AUTHORIZED REPRESENTATIVE TO TRAIN UTILITY CONNECTIONS AND TEES, FILL VOIDS BETWEEN COVERS AND PIPING WITH FIBERGLASS INSULATION AND 1583 PLUMBING SPECIALTIES IN AR10400066 SC 6834 NRTL: NATIONALLY RECOGNIZED TESTING LABORATORY, AS DEFINED AND LISTED BY OSHA IN OWNER'S DESIGNATED PERSONNEL ON THE OPERATION AND MAINTENANCE OF THE TAPE JOINTS. INSTALL PIPE INSULATION IN COMPLIANCE WITH MANUFACTURER'S VACUUM RELIEF VALVE: WATTS #N36 OR WILKINS #VR-10 WITH BRONZE BODY AND SILICON KS 4674 SD 11532 29 CFR 1910.7 (E.G., UL, ETL, CSA), AND ACCEPTABLE TO THE AHJ OVER THIS PROJECT. EQUIPMENT PROVIDED FOR THIS PROJECT. PROVIDE UTILITY CONNECTIONS REQUIRED AND INDICATED ON THE DRAWINGS. INSTALL RECOMMENDATIONS. WHERE PREMOLDED INSULATING FITTINGS ARE NOT APPROVED BY WATER HAMMER ARRESTORS AND TRAPS DISC. VALVE SHALL OPEN AT 0.5"HG VACUUM AND BE RATED FOR 200 PSIG WORKING KY 5967 TN 101374 INTERIOR AND EXTERIOR CONNECTIONS TO "MAINS" AND EXISTING SERVICE LINES COMPLETE LOCAL AUTHORITIES, MITER INSULATION AT FITTINGS. PRESSURE AND 250'F TEMPERATURE. INSTALL IN COLD WATER SUPPLY TO EACH WATER LA 5734 TX 17680 THE TERMS APPROVED EQUAL", "EQUIVALENT", OR "EQUAL" ARE USED SYNONYMOUSLY PROVIDE TRAINING TO INCLUDE BUT NOT BE LIMITED TO AN OVERVIEW OF THE SYSTEM AND FUNCTIONING, IN COMPLIANCE WITH THE REQUIREMENTS OF THE CODES HAVING PROVIDE WATER HAMMER ARRESTORS AT VALVES OR BATTERIES OF FIXTURES AS INDICATED HEATER DOWNSTREAM OF THE SHUTOFF AND CHECK VALVES. ME ARC 2596 UT 5881358-0301 AND SHALL MEAN "ACCEPTED BY OR ACCEPTABLE TO THE ENGINEER AS EQUIVALENT TO THE AND/OR EQUIPMENT AS IT RELATES TO THE FACILITY AS A WHOLE; OPERATION AND JURISDICTION AND THE SERVING UTILITY INVOLVED. VERIFY THE EXACT LOCATION OF UTILITY INSULATE WATER HEATERS, STORAGE TANKS, HOT WATER PUMPS, ETC. THAT ARE NOT ON THE DRAWINGS TO PREVENT WATER HAMMER. ARRESTORS SHALL BE JOSAM, SMITH, ITEM OR MANUFACTURER SPECIFIED". THE TERM "APPROVED" SHALL MEAN LABELED, MAINTENANCE PROCEDURES, AND SCHEDULES RELATED TO STARTUP AND SHUTDOWN, MAINS, SERVICE LINES, AND CONNECTION POINTS REQUIRING CONNECTION IN THE FIELD FACTORY INSULATED. PRECISION PLUMBING PRODUCTS, PROFLO, SIOUX CHIEF, WADE, WATTS, OR ZURN, EXPANSION TANK: EXPANSION TANK SHALL BE AMTROL "THERM-X-TROL" AS SCHEDULED ON MD 11016 VT 2572 LISTED, OR BOTH, BY AN NRTL, AND ACCEPTABLE TO THE AHJ OVER THIS PROJECT. TROUBLESHOOTING, SERVICING, PREVENTIVE MAINTENANCE, AND APPROPRIATE OPERATOR PRIOR TO INSTALLATION. WORK IN CONJUNCTION WITH THE UTILITY INVOLVED IN THE STAINLESS STEEL BELLOWS TYPE, OR 0-RING SEALED AND LUBRICATED ACETAL PISTON. THE DRAWINGS OR EQUAL BY ARMSTRONG, BELL & GOSSETT, PROFLO, TACO, OR WATTS. MA 10635 VA 0401 011223 INTERVENTION; AND REVIEW OF DATA INCLUDED IN THE OPERATION AND MAINTENANCE INSTALLATION OF SERVICES. VERIFY THAT INSTALLATION WILL TIE INTO THE EXISTING UTILITY PIPING JOINTS INSTALL WATER HAMMER ARRESTORS PER THE PLUMBING AND DRAINAGE INSTITUTE PDI UNIT SHALL BE CONSTRUCTED OF WELDED CARBON STEEL LISTED FOR 150 PSIG WORKING MI 1301052379 WA 10344 THE TERM LEAD FREE REFERS TO THE WETTED SURFACE OF PIPE, FITTINGS AND FIXTURES IN MANUALS. MAINS, SERVICE LINES, AND CONNECTION POINTS AT THE INDICATED INVERT ELEVATION WH-201 INSTALLATION INSTRUCTIONS. INSTALLATION OF ARRESTORS AT BATTERIES OF PRESSURE, WITH A FDA APPROVED BUTYL RUBBER DIAPHRAGM, TAPS FOR PRESSURE GAGE, MN 44326 WI 9900-005 POTABLE WATER SYSTEMS THAT HAVE A WEIGHTED AVERAGE LEAD CONTENT LESS THAN OR POINT PRIOR TO INSTALLATION. IF THE INSTALLATION WILL NOT TIE INTO THE INDICATED COPPER TUBING: JOINTS IN HARD TEMPER TUBING SHALL BE SOLDERED JOINTS USING LEAD- FIXTURES PRECLUDES THE REQUIREMENT FOR INDIVIDUAL AIR CHAMBERS AT EACH BATTERY AIR CHARGING FITTING, AND DRAIN FITTING. SUPPORT AS DETAILED ON THE DRAWINGS. MO A-2005029740 WV 3727 EQUAL TO 0.25% PER SAFE DRINKING WATER ACT AS AMENDED JANUARY 4, 2011 SECTION SUBMIT A CERTIFICATION LETTER TO THE ARCHITECT STATING THAT THE OWNER'S INVERT ELEVATION POINT WHILE MAINTAINING PROPER FALL, NOTIFY THE ARCHITECT AND FREE 95/5 SOLDER EXCEPT WHERE TUBING IS INSTALLED BELOW GRADE OR BELOW THE BASE FIXTURE. SUBMIT CERTIFICATION THAT WATER HAMMER ARRESTORS COMPLY WITH NSF CHARGE TANK WITH AIR PRESSURE EQUAL TO THE STATIC WATER PRESSURE. MS 3860 WY C-1967 1417. DESIGNATED REPRESENTATIVE HAS BEEN TRAINED AS SPECIFIED HEREIN. LETTER SHALL THE ENGINEER SO THAT AN ALTERNATIVE MAY BE DETERMINED. SLAB, IN WHICH CASE JOINTS SHALL BE SOLDERED WITH SILVER SOLDER (SILFOS). JOINTS IN 61 ANNEX G AND / OR NSF 372. ProtessbnalSeal: INCLUDE DATE, TIME, ATTENDEES, AND SUBJECT OF TRAINING. THE CONTRACTOR AND THE SOFT TEMPER COPPER TUBING SHALL BE OF THE FLARED TYPE INSTALLED IN COMPLIANCE HOT WATER TEMPERATURE AT THE FAUCET SHALL BE 110-F (+/-5'F). PREBID SITE VISIT OWNER'S REPRESENTATIVE SHALL SIGN THE CERTIFICATION LETTER INDICATING AGREEMENT MISCELLANEOUS REMODELING WORK WITH THE FITTING MANUFACTURER'S RECOMMENDATIONS. PROVIDE WATER-SEAL TRAPS ON FIXTURES, AND EQUIPMENT WITH DRAIN CONNECTIONS, SPED PRO,CF THAT THE TRAINING HAS BEEN PROVIDED. INCLUDING TRAPS NOT FURNISHED IN COMBINATION WITH FIXTURES AND EQUIPMENT. `ScS' PRIOR TO SUBMITTING BID, VISIT THE SITE OF THE PROPOSED WORK AND BECOME FULLY PROVIDE ITEMS OF PLUMBING SYSTEMS MODIFICATION REQUIRED BECAUSE OF BUILDING CAST IRON PIPE BELOW GRADE: JOINTS IN BELL AND SPIGOT CAST IRON WASTE AND VENT PLACE TRAP AS CLOSE TO THE FIXTURE OR DRAIN AS POSSIBLE. EXPOSED TRAPS IN FINISHED ��Gj �NGINEF9 �O, INFORMED AS TO THE CONDITIONS UNDER WHICH THE WORK IS TO BE DONE. FAILURE TO SCHEDULE TRAINING WITH OWNER WITH AT LEAST 7 DAYS' ADVANCE NOTICE. REMODELING, AS NOTED ON THE DRAWINGS, OR NECESSARY FOR PROPER OPERATION. PIPE SHALL BE NEOPRENE COMPRESSION GASKETS, TYSEAL, OR EQUAL. SPACES SHALL BE CHROME-PLATED BRASS. DO SO WILL NOT BE CONSIDERED SUFFICIENT JUSTIFICATION TO REQUEST OR OBTAIN EXTRA MATCH EXISTING MATERIALS AND CONSTRUCTION TECHNIQUES WHEN MODIFYING EXISTING `:' 84242PE COMPENSATION OVER AND ABOVE THE CONTRACT PRICE. WARRANTIES SYSTEMS. COORDINATE REQUIREMENTS WITH GENERAL CONTRACTOR AND ARCHITECT. CAST IRON PIPE ABOVE GRADE: JOINTS IN HUBLESS PIPE SHALL BE STANDARD CISPI 310 PROVIDE CONVENTIONAL "P" TYPE TRAP, WATER-SEALED SELF-CLEANING DESIGN. FULL "S" DOMESTICALLY MANUFACTURED BY ANACO, A B & I FOUNDRY, CHARLOTTE, HUSKY, IDEAL, TRAPS OR TRAP STANDARDS SHALL BE USED ONLY WHERE SPECIFICALLY CALLED FOR ON THE MATERIAL AND WORKMANSHIP COORDINATE WITH DIVISION 1 AND GENERAL CONDITIONS TO DETERMINE WHAT THE EXISTING FLOOR DRAINS REQUIRED TO BE ABANDONED OR NOT IN USE AT THE TERMINATION TYLER, MISSON, OR FERNCO. JOINTS IN STORM PIPING, INCLUDING CONNECTIONS TO ROOF DRAWINGS OR ELSEWHERE IN THIS SPECIFICATION. TRAP WATER SEALS SHALL NOT BE LESS ACTUAL REQUIREMENTS ARE, AND MODIFY THE FOLLOWING AS REQUIRED SO AS TO NOT OF THE WORK SHALL BE SEALED GAS-TIGHT. CLEAN TRAP OF DEBRIS AND FILL WITH SILICONE. DRAINS, SHALL BE HEAVY DUTY COUPLINGS MEETING ASTM C1540 AND FM 1680, ANACO THAN 2", AND DEEP SEAL TRAPS SHALL BE PROVIDED WHERE SPECIFIED OR INDICATED. EACH MATERIAL, EQUIPMENT, AND APPARATUS PROVIDED UNDER THIS CONTRACT SHALL BE NEW CONTRADICT THEM. REMOVE GRATE AND FILL DRAIN BODY WITH GROUT. IN THE FINISHED PORTIONS OF THE HUSKY #SD-4000 OR CLAMP-ALL "HI TORQUE" 125 IN. LB. TRAP NOT INTEGRAL WITH THE FIXTURE OR INSTALLED BELOW THE BASE SLAB SHALL BE E N UNLESS OTHERWISE STATED HEREIN, OF BEST QUALITY NORMALLY USED FOR THE PURPOSE BUILDING THEY SHALL BE COVERED WITH FLOOR MATERIAL MATCHING ADJACENT AREA. ANY PROVIDED WITH AN ACCESSIBLE CLEANOUT OF ADEQUATE SIZE. PROVIDE TRAP PRIMERS y G y -�� IN GOOD COMMERCIAL PRACTICE, AND FREE FROM DEFECTS. MODEL NUMBERS LISTED IN WARRANT EACH SYSTEM AND EACH ELEMENT THEREOF AGAINST ALL DEFECTS DUE TO FLOOR DEPRESSIONS RESULTING FROM ABANDONED FLOOR DRAINS SHALL BE LEVELED PVC PIPE: CLEAN JOINTS FREE FROM DEBRIS AND MOISTURE. APPLY PVC PRIMER MEETING WHERE REQUIRED BY CODE AND WHERE INDICATED ON THE DRAWINGS. �� SPECIFICATIONS OR SHOWN ON THE DRAWINGS ARE NOT NECESSARILY INTENDED TO FAULTY WORKMANSHIP, DESIGN, OR MATERIAL FOR A PERIOD OF 12 MONTHS FROM DATE BEFORE FINAL FLOOR FINISHING. ASTM F656 TO EACH JOINT. APPLY SOLVENT CEMENT MEETING ASTM D2564 AND MAKE I DESIGNATE THE REQUIRED TRIM, WRITTEN DESCRIPTIONS OF THE TRIM GOVERN MODEL OF SUBSTANTIAL COMPLETION, UNLESS SPECIFIC ITEMS ARE NOTED TO CARRY A LONGER JOINT WHILE WET AND IN ACCORDANCE WITH ASTM D2855. CLEANOUTS AND FLOOR DRAINS d NUMBERS. WARRANTY IN THE CONSTRUCTION DOCUMENTS OR MANUFACTURER'S STANDARD NEW FLOOR DRAINS SHALL BE CONNECTED TO THE EXISTING SANITARY DRAINAGE SYSTEM AS WARRANTY EXCEEDS 12 MONTHS. REMEDY ALL DEFECTS, OCCURRING WITHIN THE SHOWN ON THE DRAWINGS OR AS REQUIRED. SAW-CUT EXISTING CONCRETE FLOOR AS PIPE ADAPTERS: MAKE CONNECTION OF NEW WASTE PIPE TO NEW OR EXISTING DISSIMILAR CLEANOUTS AND FLOOR DRAINS SHALL BE BY ONE MANUFACTURER IF POSSIBLE. EXP ES: 1 PIPE, PIPE FITTINGS, PIPE SPECIALTIES, AND VALVES SHALL BE MANUFACTURED IN PLANTS WARRANTY PERIOD(S), AS STATED IN THE GENERAL CONDITIONS AND DIVISION 1. REQUIRED TO INSTALL NEW UNDERFLOOR LINES, AND PATCH TO MATCH EXISTING SUB- WASTE PIPE USING ADAPTER COUPLINGS. PROVIDE FERNCO, PROFLEX 3000 SERIES, OR ACCEPTABLE MANUFACTURERS ARE JOSAM, SMITH, WADE, WATTS, AND ZURN. PROVIDE 1 LOCATED IN THE UNITED STATES. FLOOR. REFER TO ARCHITECTURAL SPECIFICATIONS FOR FINISH FLOOR PATCHING MISSION FLEXSEAL MR56 SERIES WITH NEOPRENE ADAPTER GASKET WITH STAINLESS STEEL LONG SWEEP FITTINGS FOR CLEANOUT EXTENSIONS; SHORT SWEEPS AT START OF RUNS OR WARRANTIES SHALL INCLUDE LABOR AND MATERIAL. MAKE REPAIRS OR REPLACEMENTS REQUIREMENTS. SHIELD AND HOSE CLAMPS FOR CONNECTING DISSIMILAR PIPES ABOVE GRADE. PROVIDE CHANGE IN DIRECTION AND COMBINATION WYE AND EIGHT BEND FITTINGS IN HORIZONTAL WORK PERFORMED UNDER THIS CONTRACT SHALL PROVIDE A NEAT AND "WORKMANLIKE" WITHOUT ANY ADDITIONAL COSTS TO THE OWNER. FERNCO, 1056 SERIES OR MISSION SEWER COUPLINGS WITH NEOPRENE ADAPTER GASKET RUNS. INSTALL CLEANOUTS WITH A MINIMUM OF 18" CLEAR ALL AROUND, CONSULT LOCAL � � APPEARANCE WHEN COMPLETED, TO THE SATISFACTION OF THE ARCHITECT AND ENGINEER. EXISTING PLUMBING FIXTURES WHERE INDICATED ON THE DRAWINGS TO BE REUSED SHALL AND HOSE CLAMPS FOR CONNECTING DISSIMILAR PIPES BELOW GRADE AND COAT STAINLESS CODES FOR OTHER REQUIREMENTS, FOR EASY SYSTEM MAINTENANCE. INSTALL PLUG WITH WORKMANSHIP SHALL BE THE FINEST POSSIBLE BY EXPERIENCED MECHANICS. PERFORM THE REMEDIAL WORK PROMPTLY, UPON WRITTEN NOTICE FROM THE ENGINEER BE CLEANED, REPAIRED, PROVIDED WITH NEW WASHERS, ETC. AS REQUIRED TO PUT THEM STEEL BANDS WITH MASTIC. TEFLON JOINT COMPOUND. INSTALLATIONS SHALL BE MADE IN A MANNER THAT WILL COMPLY WITH APPLICABLE CODES OR OWNER. INTO GOOD OPERATING CONDITION. AND LAWS. PIPING INSTALLATION FLOOR CLEANOUTS: SHALL BE AS SCHEDULED ON THE DRAWINGS. INSTALL CLEANOUTS AT AT THE TIME OF SUBSTANTIAL COMPLETION, DELIVER TO THE OWNER ALL WARRANTIES, IN PATCH HOLES WEATHER-TIGHT IN EXISTING ROOFS CAUSED BY REMOVAL OF PLUMBING POINTS AS NOTED ON THE DRAWINGS, AT THE BUILDING EXIT; AT A MINIMUM OF EVERY 50 INSTALLATION SHALL FUNCTION AS DESIGNED AND INTENDED WITH RESPECT TO EFFICIENCY, WRITING AND PROPERLY EXECUTED, INCLUDING TERM LIMITS FOR WARRANTIES EXTENDING ITEMS SUCH AS PIPING. GENERAL: CLEAN PIPE THOROUGHLY PRIOR TO INSTALLATION. REAM ENDS OF PIPE TO FEET IN HORIZONTAL SOIL AND WASTE LINES; AND AT TURNS OF PIPE GREATER THAN 45 CAPACITY, AND NOISE LEVEL, ETC. ABNORMAL NOISE CAUSED BY RATTLING EQUIPMENT OR BEYOND THE ONE YEAR PERIOD, EACH WARRANTY INSTRUMENT BEING ADDRESSED TO THE REMOVE BURRS. CUT PIPE ACCURATELY TO MEASUREMENTS TAKEN ON THE JOB. INSTALL DEGREES CLEANOUTS SHALL BE FULL SIZE OF THE PIPE UP TO 4", AND 4" SIZE FOR PIPES HENDERSON PIPING AND SQUEAKS IN ROTATING COMPONENTS WILL NOT BE ACCEPTABLE. MATERIALS OWNER AND STATING THE COMMENCEMENT DATE AND TERM. MAKE CONNECTION OF NEW PIPE TO SIMILAR EXISTING WASTE, WATER AND GAS PIPE USING WITH ADEQUATE CLEARANCE FOR INSTALLATION OF COVERINGS WHERE REQUIRED. PIPE LARGER THAN 4". DETERMINE THE TYPE OF FLOOR COVERING TO BE USED AT EACH FLOOR AND EQUIPMENT SHALL BE OF COMMERCIAL SPECIFICATION GRADE IN QUALITY. LIGHT DUTY STANDARD FITTINGS AND JOINING PRACTICES. SHALL NOT BE SPRUNG OR BENT. NEATLY ALIGN PIPE, CONNECT IT SECURELY, AND SUPPORT CLEANOUT LOCATION AND PROVIDE TOP WITH VARIATIONS SUITABLE FOR FLOOR COVERING ENGINEERS-N AND RESIDENTIAL GRADE EQUIPMENT WILL NOT BE ACCEPTED UNLESS OTHERWISE SPARE PARTS IT FROM THE BUILDING STRUCTURE WITH HANGERS AS SPECIFIED BELOW. PROVIDE (CARPET MARKERS, RECESSED FOR TILE AND SCORIATED FOR UNFINISHED FLOOR). ROUGH-IN INDICATED. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING EXISTING HVAC EQUIPMENT CHROME-PLATED ESCUTCHEONS ON PIPES PASSING THROUGH CEILINGS, FLOORS, OR WALLS AND INSTALL EACH FLOOR CLEANOUT FLUSH WITH THE FINISHED FLOOR CONSTRUCTION. 8345 LENEXA DRIVE,SUfTE 300 FURNISH TO OWNER, WITH RECEIPT, THE SPARE PARTS TO INCLUDE FAUCET WASHERS AND CONDENSATE DRAINAGE IS EXISTING AND INSTALLED PER CODE AND COORDINATING WITH OF FINISHED SPACES. RUN PIPES FREELY THROUGH FLOOR AND WALL PENETRATIONS USING LENEXA,KS 66214 REMOVE FROM THE PREMISES WASTE MATERIAL PRESENT AS A RESULT OF HIS WORK, 0-RINGS, FLUSHOMETER REPAIR KITS, AND WATER CLOSET TANK REPAIR KITS FOR THE MECHANICAL AND PLUMBING CONTRACTORS TO PROVIDE NEW CONDENSATE DRAINAGE TO PIPE SLEEVES. DO NOT GROUT IN PLACE UNLESS REQUIRED FOR STRUCTURAL FIRE INTEGRITY. WALL CLEANOUTS: SHALL BE AS SCHEDULED ON THE DRAWINGS. INSTALL WALL CLEANOUTS TEL 913 742 5000 Fax 913 742 5001 INCLUDING CARTONS, CRATING, PAPER, STICKERS, AND/OR EXCAVATION MATERIAL NOT FIXTURES FURNISHED FOR THIS PROJECT. MEET CODE AS NECESSARY. INSTALL PIPE CONCEALED IN FINISHED SPACES WHEREVER POSSIBLE. USE A DIELECTRIC AT POINTS AS NOTED ON THE DRAWINGS; AT THE FOOT OF EACH SOIL, WASTE, OR INTERIOR USED IN BACKFILLING, ETC. CLEAN PIECES OF EQUIPMENT INSTALLED UNDER THIS CONTRACT UNION WHERE FERROUS AND COPPER PIPE CONNECT. DIELECTRIC UNION SHALL HAVE A DOWNSPOUT STACK; AT HORIZONTAL SOIL AND WASTE BRANCHES LONGER THAN FIVE FEET www.hei-eng.Wm TO PRESENT A NEAT AND CLEAN INSTALLATION AT THE TERMINATION OF THE WORK. EXCAVATION AND BACKFILLING SYSTEM TESTING AND ADJUSTING ZINC-PLATED STEEL BODY, A THREADED NYLON INSERT, AND INSULATING PRESSURE GASKET. NOT SERVED BY A FLOOR CLEANOUT; CONSULT LOCAL CODES FOR INSTALLATION AT SPECIFIC 1550003152 NO FERROUS METAL-TO-COPPER CONNECTION MADE WITHOUT INSULATING UNIONS WILL FIXTURE TYPES. INSTALL WALL CLEANOUTS ABOVE THE FLOOD RIM OF THE FIXTURE SERVED REPAIR OR REPLACE PUBLIC AND PRIVATE PROPERTY DAMAGED AS A RESULT OF WORK PERFORM EXCAVATION AND BACKFILL REQUIRED FOR INSTALLATION OF UNDERGROUND UPON COMPLETION OF EACH PHASE OF THE INSTALLATION, TEST EACH SYSTEM IN BE ALLOWED. WITHIN FOUR FEET OF THE FLOOR AND INSTALL EXTENSIONS FROM THE CLEANOUT TEE TO PERFORMED UNDER THIS CONTRACT TO THE SATISFACTION OF AUTHORITIES AND WORK UNDER THIS CONTRACT. TRENCHES SHALL BE OF SUFFICIENT WIDTH. CRIB OR BRACE CONFORMANCE WITH LOCAL CODE REQUIREMENTS AND AS NOTED BELOW. FURNISH LABOR THE WALL TO LOCATE THE PLUG WITHIN 2" OF THE WALL WHERE REQUIRED. INSTALL REGULATIONS HAVING JURISDICTION. TRENCHES TO PREVENT CAVE-IN OR SETTLEMENT. DO NOT EXCAVATE TRENCHES CLOSE TO AND EQUIPMENT REQUIRED TO TEST PLUMBING WORK INSTALLED UNDER THIS CONTRACT, HANGER & SUPPORTS: PIPE HANGERS SHALL BE AS DESCRIBED IN THE SPECIFICATIONS BY B- CLEANOUTS ON URINALS AND SINKS WHERE REQUIRED BY CODE. kb Name and Number. 2015-0131 COLUMNS AND WALLS OF NEW BUILDING WITHOUT PRIOR CONSULTATION WITH THE AND ASSUME COSTS INVOLVED IN MAKING THE TESTS, AND REPAIRING AND/OR REPLACING LINE OR EQUAL BY ANVIL, MICHIGAN, TRUSCON, OR UNISTRUT. CONNECT HANGERS TO THE COORDINATION ARCHITECT. USE PUMPING EQUIPMENT IF REQUIRED TO KEEP TRENCHES FREE OF WATER. DAMAGE RESULTING THEREFROM. STRUCTURE WITH SIDE BEAM CONNECTORS AND ALL THREAD HANGER RODS. PROVIDE VALVES AND UNIONS BACKFILL TRENCHES IN MAXIMUM 6" LAYERS OF WELL-TAMPED DRY EARTH IN A MANNER TO ENGINEERED SUPPORT STRUTS BETWEEN JOISTS AND OTHER STRUCTURAL MEMBERS AS COORDINATE WORK WITH THAT OF OTHER TRADES SO THAT THE VARIOUS COMPONENTS OF PREVENT FUTURE SETTLEMENT. NOTIFY THE ARCHITECT AND THE AUTHORITY HAVING JURISDICTION, THREE (3) WORKING REQUIRED TO PROVIDE A RIGID HANGING INSTALLATION. DO NOT HANG PIPES FROM OTHER PLUMBING SYSTEM VALVES SHALL BE CRANE COMPANY OR NIBCO OF MODELS HEREIN THE SYSTEMS WILL BE INSTALLED AT THE PROPER TIME, WILL FIT THE AVAILABLE SPACE, AND DAYS PRIOR TO MAKING PLUMBING SYSTEM TESTS. LEAVE CONCEALED WORK UNCOVERED PIPES, CONDUIT, OR DUCTWORK. PROVIDE HANGER RODS AND SPACE HANGERS AT SPECIFIED, OR APPROVED EQUAL BY HAMMOND, MILWAUKEE, STOCKHAM OR MUELLER Proposed WILL ALLOW PROPER SERVICE ACCESS TO THOSE ITEMS REQUIRING MAINTENANCE. EXCAVATION AS HEREIN SPECIFIED SHALL BE CLASSIFIED AS COMMON EXCAVATION. UNTIL THE REQUIRED TESTS HAVE BEEN COMPLETED, BUT IF NECESSARY DUE TO INTERVALS AS SPECIFIED IN "HANGER SPACING". PROVIDE SUPPORT WITHIN 1' OF EACH VALVES. VALVES SHALL BE OF THE BEST QUALITY, DESIGNED FOR 125 PSI STEAM WORKING COMPONENTS WHICH ARE INSTALLED WITHOUT REGARD TO THE ABOVE SHALL BE COMMON EXCAVATION SHALL COMPRISE THE SATISFACTORY REMOVAL AND DISPOSITION OF CONSTRUCTION PROCEDURE, TESTS ON PORTIONS OF THE WORK MAY BE MADE, AND WHEN ELBOW AND TEE. PROVIDE SUPPORTS WITHIN 1' OF EACH EQUIPMENT CONNECTION. PRESSURE AND 200 PSI COLD WATER PRESSURE. INSTALL VALVES ON THE HOT AND COLD RELOCATED AT NO ADDITIONAL COST TO THE OWNER. MATERIAL OF WHATEVER SUBSTANCES AND OF EVERY DESCRIPTION ENCOUNTERED, SATISFACTORY, THE WORK MAY BE CONCEALED. TEST PIPING BEFORE INSULATION IS PROVIDE TWO NUTS ON THREADED SUPPORTS TO SECURELY FASTEN THE SUPPORT. INSTALL WATER LINES AT THE WATER HEATER CONNECTIONS AND OTHER ITEMS OF EQUIPMENT, AT VE R IZO N INCLUDING ROCK, IF ANY, WITHIN THE LIMITS OF THE WORK AS SPECIFIED AND SHOWN ON INSTALLED, AND BEFORE BACKFILL. PIPES, JOINTS, FLANGES, VALVE STEMS, ETC., SHALL BE HANGER TYPES OR SUPPORTS FOR VARIOUS PIPING AS FOLLOWS: BRANCHES FROM MAINS SERVING GROUPS OF FIXTURES, AND AT OTHER PLACES INDICATED UNLESS NOTED ELSEWHERE, GENERAL CONTRACTOR WILL PROVIDE CHASES AND OPENINGS THE DRAWINGS. EXCAVATION SHALL BE PERFORMED TO THE LINES AND GRADES INDICATED LEAK TIGHT. REPAIR OR REPLACE SYSTEM DEFECTS WITH NEW MATERIALS. CAULKING OF OR REQUIRED BY THE INSTALLATION TO ALLOW EASE OF FUTURE MAINTENANCE. SUBMIT IN BUILDING CONSTRUCTION REQUIRED FOR INSTALLATION OF THE SYSTEMS SPECIFIED ON THE DRAWINGS. EXCAVATED MATERIALS WHICH ARE CONSIDERED UNSUITABLE FOR DEFECTIVE JOINTS, CRACKS, OR HOLES WILL NOT BE PERMITTED. REPEAT TESTS AFTER COPPER TUBE: ADJUSTABLE BAND HANGERS FOR BARE COPPER TUBE 3" AND SMALLER CERTIFICATION THAT VALVES, FITTINGS AND SPECIALTIES COMPLY WITH NSF 61 ANNEX G STO R E HEREIN. CONTRACTOR SHALL FURNISH THE GENERAL CONTRACTOR WITH INFORMATION BACKFILL, AND SURPLUS OF EXCAVATED MATERIAL WHICH IS NOT REQUIRED FOR BACKFILL, DEFECTS HAVE BEEN ELIMINATED. MAKE TESTS IN THE PRESENCE OF THE ADMINISTRATIVE SHALL BE B-LINE #B3170 CT COPPER PLATED ADJUSTABLE BAND SWIVEL RING TYPE. AND / OR NSF 372. REGARDING CHASES AND OPENINGS WHEN REQUIRED. CONTRACTOR SHALL KEEP INFORMED SHALL BE DISPOSED OF BY THE CONTRACTOR AT HIS OWN EXPENSE AND RESPONSIBILITY, AUTHORITY AND/OR THE OWNER'S AUTHORIZED REPRESENTATIVE. ADJUSTABLE BAND HANGERS FOR INSULATED COPPER TUBE AND 3" SMALLER SHALL BE B- AS TO THE WORK OF OTHER TRADES ENGAGED IN THE CONSTRUCTION OF THE PROJECT, AND AND TO THE SATISFACTION OF THE ARCHITECT. LINE #B3170 NF ADJUSTABLE BAND SWIVEL RING TYPE. CLEVIS HANGERS FOR INSULATED BALL VALVES 2" AND SMALLER: (MAY BE USED IN LIEU OF GATE VALVES UP TO 2")Class 150, (L E E D) SHALL EXECUTE HIS WORK IN SUCH A MANNER AS NOT TO INTERFERE WITH OR DELAY THE UPON COMPLETION OF THE SYSTEMS INSTALLATION, AND PRIOR TO ACCEPTANCE BY THE COPPER TUBE 4" AND LARGER SHALL BE B-LINE #83100 GALVANIZED STEEL CLEVIS TYPE. TWO PIECE LEAD FREE CAST BRONZE BODY, WITH SWEAT ENDS, CHROME PLATED BRONZE WORK OF OTHER TRADES. COINCIDENTAL DAMAGE ARCHITECT AND ENGINEER, MAKE GENERAL OPERATING TESTS TO DEMONSTRATE THAT SUPPORT EXPOSED COPPER TUBE 2" AND SMALLER TO WALLS OR IN CHASES WITH B-LINE BALL WITH CONVENTIONAL PORT, 600 PSI, BLOW-OUT PROOF STEM BY APOLLO # 70-LF-200, EQUIPMENT AND SYSTEMS ARE IN PROPER WORKING ORDER, AND ARE FUNCTIONING IN #B3198RCT COPPER COATED EXTENSION SPLIT RING PIPE CLAMPS, 3/8" THREADED ROD AND HAMMOND # UP8501, MILWAUKEE # UPBA-150. FIGURED DIMENSIONS SHALL BE TAKEN IN PREFERENCE TO SCALED DIMENSIONS. CONTRACTOR SHALL REPAIR STREETS, SIDEWALKS, DRIVES, PAVING, WALLS AND FINISHES CONFORMANCE WITH THE INTENT OF THE DRAWINGS AND SPECIFICATIONS. AS A PART OF B-LINE #B3199CT CEILING FLANGES. SUPPORT COPPER TUBE IN CHASES AND WALLS AT CONTRACTOR SHALL TAKE HIS OWN MEASUREMENTS AT THE BUILDING, AS VARIATIONS MAY ETC. THAT HE DAMAGES IN THE COURSE OF THIS PROJECT. REPAIR MATERIALS SHALL MATCH THESE TESTS, OPEN EVERY WATER OUTLET TO ENSURE COMPLETE SYSTEM FLUSHING, PLUMBING FIXTURES WITH PLASTIC OR COPPER BRACKETS SECURED TO STRUCTURE AND U- SWING CHECK VALVES 2" AND SMALLER: CLASS 125, LEAD FREE CAST BRONZE BODY AND OCCUR. CONTRACTOR WILL BE HELD RESPONSIBLE FOR ERRORS WHICH COULD HAVE BEEN EXISTING CONSTRUCTION. REPAIR WORK SHALL MEET REQUIREMENTS OF THE LOCAL REMOVE AND CLEAN FAUCET AERATORS, CLEAN STRAINERS, LIGHT PILOT LIGHTS, AND BOLTS SIZED TO BARE ON THE PIPE. RISER CLAMPS TO SUPPORT VERTICAL COPPER TUBE WITH SWEAT ENDS BY APOLLO # 163S-LF,MILWAUKEE #UP-1509, OR NIBCO # S-413-Y-LF. AVOIDED BY PROPER CHECKING AND VERIFICATION. AUTHORITIES HAVING JURISDICTION AND MEET THE SATISFACTION OF THE ARCHITECT. OPERATE EVERY PIECE OF EQUIPMENT FURNISHED UNDER THIS CONTRACT TO SHALL BE B-LINE #B3373CT COPPER COATED STEEL, CUT INSULATION, SEAL VAPOR BARRIER, INSTALL IN HORIZONTAL PIPE RUNS. DEMONSTRATE PROPER FUNCTIONING. AND ATTACH TO BARE TUBE. PROVIDE MATERIALS WITH TRIM THAT WILL PROPERLY FIT THE TYPES OF CEILING, WALL, OR CUTTING AND PATCHING LIFT CHECK VALVES 2" AND SMALLER: CLASS 125, LEAD FREE CAST BRONZE BODY, STAINLESS JobAddre� FLOOR FINISHES ACTUALLY INSTALLED. MODEL NUMBERS LISTED IN THE SPECIFICATIONS OR TEST THE DRAINAGE AND VENT SYSTEM BY PLUGGING OPENINGS WITH TEST PLUGS, EXCEPT CAST IRON PIPE: ADJUSTABLE BAND HANGERS FOR 2" AND SMALLER. CLEVIS HANGERS FOR STEEL SPRING AND WITH SWEAT ENDS BY HAMMOND # LP-947 OR NIBCO # S-413-Y-LF. + SHOWN ON THE DRAWINGS ARE NOT INTENDED TO DESIGNATE THE REQUIRED TRIM. OBTAIN PERMISSION FROM THE ARCHITECT BEFORE CUTTING WALLS, FLOORS, CEILINGS, ETC. THOSE AT THE TOP OF THE STACKS. FILL THE SYSTEM WITH WATER; TEST RESULTS WILL BE 3" AND LARGER SHALL BE B-LINE #63100 GALVANIZED STEEL CLEVIS TYPE. RISER CLAMPS TO INSTALL IN VERTICAL PIPE OR IN HORIZNTAL RUNS WHERE REQUIRED. (Washington Square Mall AS REQUIRED BY THE PROJECT. DO NOT DISTURB STRUCTURAL MEMBERS WITHOUT PRIOR SATISFACTORY IF THE WATER LEVEL REMAINS STATIONARY FOR NOT LESS THAN ONE (1) SUPPORT VERTICAL PIPE SHALL BE B-LINE #83373 GALVANIZED STEEL. 7905 S.W. Washington ORDINANCES AND CODES APPROVAL FROM THE ARCHITECT. CUT HOLES AS SMALL AS POSSIBLE. GENERAL HOUR. SUBJECT THE DRAINAGE AND VENT SYSTEM TO A PRESSURE OF AT LEAST TEN (10) UNIONS: FERROUS UNIONS SHALL BE CRANE OR EQUAL, COMBINATION IRON AND BRASS, CONTRACTOR SHALL PATCH WALLS, FLOORS, ETC. AS REQUIRED BY WORK UNDER THIS FEET OF WATER. IF LEAKS DEVELOP, REPAIR THEM AND REPEAT THE TEST. PVC PIPE: ADJUSTABLE BAND HANGERS FOR 3' AND SMALLER. CLEVIS HANGERS FOR 4" AND GROUND JOINT WITH SCREWED ENDS. COPPER UNIONS SHALL BE STREAMLINE OR EQUAL, S//'+JJuare Road WORK PERFORMED UNDER THIS CONTRACT SHALL, AT A MINIMUM, BE IN CONFORMANCE SECTION. PATCHING SHALL MATCH ORIGINAL MATERIAL AND CONSTRUCTION. REPAIR AND LARGER SHALL BE B LINE #83100 GALVANIZED STEEL CLEVIS TYPE. RISER CLAMPS TO CAST BRONZE SWEAT TYPE WITH GROUND JOINT. FERROUS TO COPPER UNIONS SHALL BE M O WITH APPLICABLE NATIONAL, STATE, AND LOCAL CODES HAVING JURISDICTION. EQUIPMENT REFINISH AREAS DISTURBED BY WORK TO THE CONDITION OF ADJOINING SURFACES IN A TEST THE DOMESTIC WATER SYSTEM BY FILLING IT WITH WATER AND THEN ISOLATING THE SUPPORT VERTICAL PIPE SHALL BE B-LINE #83373 GALVANIZED STEEL. UNIVERSAL CONTROLS OR EQUAL, DIELECTRIC TYPE WITH THREADED NYLON INSERT. Portland OR 97223 FURNISHED AND ASSOCIATED INSTALLATION WORK PERFORMED UNDER THIS CONTRACT MANNER SATISFACTORY TO THE ARCHITECT. SYSTEM FROM ITS SOURCE. KEEP THE SYSTEM CLOSED FOR A PERIOD OF TWENTY-FOUR t p SHALL BE IN STRICT COMPLIANCE WITH CURRENT APPLICABLE CODES ADOPTED BY THE LOCAL HOURS, WITH NO FIXTURE BEING USED. THE PRESSURE DIFFERENTIAL FOR THIS TEST PERIOD INSULATION PROTECTION SHIELDS: B-LINE #63151 OF 18 GAUGE GALVANIZED SHEET METAL. THERMOSTATIC MIXING VALVES: THERMOSTATIC MIXING VALVES SHALL BE POWERS AS n AHJ INCLUDING ANY AMENDMENTS AND STANDARDS AS SET FORTH BY THE NATIONAL FIRE ROUGH-IN SHALL NOT EXCEED 10 PSIG. TEST WATER PIPING TO A 125 PSI HYDROSTATIC PRESSURE. SHIELD SHALL COVER HALF OF THE CIRCUMFERENCE OF THE PIPE AND SHALL BE OF LENGTH DESCRIBED ON THE DRAWINGS OR EQUAL BRADLEY, LEONARD, LAWLER, SYMMONS OR Space R05-R07 a_ PROTECTION ASSOCIATION (NFPA), UNDERWRITERS LABORATORIES (UL), OCCUPATIONAL INDICATED BY MANUFACTURER FOR PIPE SIZE AND THICKNESS OF INSULATION. WATTS MEETING ASSE 1070 WITH LEAD FREE BRASS BODY, NON-CORROSIVE INTERNAL LO SAFETY AND HEALTH ADMINISTRATION (OSHA), AMERICAN SOCIETY OF MECHANICAL BEFORE STARTING CONSTRUCTION, COORDINATE WITH OTHER CONTRACTORS REGARDING GUARANTEE PARTS, TAMPER RESISTANT TEMPERATURE ADJUSTMENT, UNION INLETS AND CHECK STOPS ENGINEERS (ASME), AMERICAN SOCIETY OF HEATING, REFRIGERATION, AND AIR ROUGH-IN WITH GENERAL CONSTRUCTION. CONCEAL PIPING, CONDUIT, AND ROUGH-IN HANGER SPACING, ROD SIZES, & CONNECTORS: CONNECT RODS TO STEEL BEAMS OR JOISTS WITH STRAINERS. SET TEMPERATURE AS SCHEDULED ON THE DRAWINGS. SET DrawlngTide: o CONDITIONING ENGINEERS (ASHRAE), AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI), EXCEPT IN UNFINISHED AREAS AND WHERE OTHERWISE SHOWN. THE WORK TO BE PERFORMED UNDER THIS CONTRACT SHALL INCLUDE THE FURNISHING, WITH B-LINE #83031 OR #B3033BEAM CLAMPS AS REQUIRED. CONNECT RODS TO CONCRETE TEMPERATURE AT 110'F FOR HAND WASHING. AMERICAN SOCIETY OF TESTING MATERIALS (ASTM) AND OTHER NATIONAL STANDARDS AND INSTALLATION, AND CONNECTION OF PLUMBING SYSTEMS INDICATED ON THE DRAWINGS WITH B-LINE #3014 MALLEABLE IRON SINGLE TYPE INSERTS WITH MALLEABLE IRON NUT. PLUMBING c LO CODES WHERE APPLICABLE. WHERE THE CONTRACT DOCUMENTS EXCEED THE STRUCTURAL STEEL AND IN THE SPECIFICATIONS. BY SIGNING THE CONTRACT, THE CONTRACTOR CONNECT RODS IN WOOD CONSTRUCTION WITH B-LINE #83058 SIDE BEAM CONNECTORS. SYSTEM ACCESSORIES ��++ j� > REQUIREMENTS OF THE REFERENCED CODES, STANDARDS, ETC., THE CONTRACT DOCUMENTS ACKNOWLEDGES THAT HE HAS ACQUAINTED HIMSELF WITH THE SITE AND THE EXISTING HANG AND SUPPORT PIPING WITH SPACING AND ROD SIZES AS FOLLOWS: �7PECIFICATILNS ' SHALL TAKE PRECEDENCE. STRUCTURAL STEEL USED FOR PIPE SUPPORTS, EQUIPMENT SUPPORTS, ETC., SHALL BE NEW CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED, AND THE DRAWINGS AND NOT USED. m M AND CLEAN, AND SHALL CONFORM TO ASTM DESIGNATION A-36. SPECIFICATIONS PERTAINING THERETO, AND HE INDICATES THAT HE WILL COMPLY WITH THE COPPER TUBE: 1-1/2" AND SMALLER - EVERY 6' WITH 3/8"HANGER RODS; 2" EVERY 10' WITH a -1 PROCURE AND PAY FOR PERMITS AND LICENSES REQUIRED FOR THE ACCOMPLISHMENT OF REQUIREMENTS AND INTENT OF PERTINENT DOCUMENTS IN THE PERFORMANCE OF THE 3/8"HANGER RODS; 2-1/2" EVERY 10' WITH 3/8" HANGER RODS; 3" EVERY 10' WITH 1/2" Q a_ THE WORK HEREIN DESCRIBED. WHERE REQUIRED, OBTAIN, PAY FOR, AND FURNISH SUPPORT PLUMBING EQUIPMENT AND PIPING FROM THE BUILDING STRUCTURE. DO NOT WORK. RODS, 4" EVERY 10' WITH 5/8" HANGER RODS. SUPPORT VERTICAL COPPER TUBE EVERY 10'. : p/ CERTIFICATES OF INSPECTION TO OWNER. THE CONTRACTOR WILL BE HELD RESPONSIBL`: SUPPORT PLUMBING EQUIPMENT AND PIPING FROM CEILINGS, OTHER MECHANICAL OR 1584 PLUMBING FIXTURES AND EQUIPMENT Q O FOR ANY VIOLATION OF THE LAW. MAINTAIN NECESSARY SIGNAL LIGHTS AND GUARDS FOR ELECTRICAL COMPONENTS, AND OTHER NON—STRUCTURAL ELEMENTS. GUARANTEE THAT THE PLUMBING INSTALLED UNDER THIS CONTRACT IS FREE OF DEFECTS IN CAST IRON PIPE: EVERY 10' AND WITHIN 1' OF EACH JOINT. 2" AND SMALLER WITH 3/8" o j THE SAFETY OF THE PUBLIC. WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF JOB HANGER RODS; 3" WITH 1/2" HANGER RODS; 4" WITH 5/8" HANGER RODS; 6" WITH 3/4" PLUMBING FIXTURES N irO ACCESS DOORS ACCEPTANCE BY THE OWNER. THIS SHALL INCLUDE A GUARANTEE OF FREE CIRCULATION OF HANGER RODS; 8" AND LARGER WITH 7/8" HANGER RODS. SUPPORT VERTICAL CAST IRON PROTECTION OF EQUIPMENT AND MATERIAL LIQUIDS THROUGHOUT THE SYSTEM AS INTENDED WITHOUT LEAKS, EXCESSIVE NOISE, OR PIPE EVERY 15'. FURNISH AND INSTALL COMMERCIAL GRADE PLUMBING FIXTURES, SEE THE DRAWINGS FOR rn I PROVIDE ACCESS DOORS IN CEILINGS AND WALLS WHERE INDICATED OR REQUIRED FOR WATER HAMMER. QUANTITIES AND DESCRIPTIONS. PROVIDE CHINA FIXTURES AS SCHEDULED BY MANSFIELD Drawn By. North o STORE AND PROTECT FROM DAMAGE EQUIPMENT AND MATERIAL AFTER DELIVERY TO JOB ACCESS TO CONCEALED VALVES AND EQUIPMENT INSTALLED UNDER THIS SECTION. PROVIDE PVC PIPE: SUPPORT ALL PIPES SIZES EVERY 4'. 1-1/2" AND SMALLER WITH 3/8" HANGER OR APPROVED EQUAL BY AMERICAN-STANDARD, CAROMA, CRANE, EL�JER, GERBER, KOHLER, Anon"' CY) CK SITE. COVER WITH WATERPROOF, TEAR—RESISTANT, HEAVY TARP OR POLYETHYLENE PLASTIC CONCEALED HINGES, SCREWDRIVER—TYPE LOCK, ANCHOR STRAPS; MANUFACTURED BY IF DEFECTS OCCUR DURING THE ONE YEAR GUARANTEE PERIOD, REPAIR OR REPLACE SUCH RODS; 2" WITH 1/2"HANGER RODS; 2-1/2" AND 3" WITH 1/2" HANGER RODS, 4" AND TOTO—KIKI, OR ZURN. PROVIDE STAINLESS STEEL SINKS AS SCHEDULED BY ELKAY OR EQUAL BY N Q AS REQUIRED TO PROTECT FROM PLASTER, DIRT, PAINT, WATER, OR PHYSICAL DAMAGE. MILCOR, ZURN, TITUS, OR EQUAL. OBTAIN ARCHITECT'S APPROVAL OF TYPE, SIZE, LOCATION, DEFECTS AT NO EXPENSE TO THE OWNER, AND TO THE SATISFACTION OF THE OWNER, LARGER WITH 5/8" HANGER RODS. SUPPORT VERTICAL PVC PIPE EVERY 4'. JUST. PROVIDE ELECTRIC WATER COOLERS AS SCHEDULED BY ELKAY OR APPROVED EQUAL BY a ��' r O EQUIPMENT AND MATERIAL DAMAGED BY CONSTRUCTION ACTIVITIES WILL BE REJECTED, AND COLOR BEFORE ORDERING. ARCHITECT AND ENGINEER. ACORN / AQUA, HALSEY TAYLOR, OR HAWS. PROVIDE MOP SINKS AS SCHEDULED BY STERN— O F- AND CONTRACTOR IS OBLIGATED TO FURNISH NEW EQUIPMENT AND MATERIAL OF A LIKE BELOW GROUND INSTALLATION FOR SOIL AND WASTE: INSTALL SOIL AND WASTE PIPING TO WILLIAMS OR EQUAL BY ACORN ENGINEERING CO., FIAT, OR FLORESTONE. PROVIDE Date Issued For a I KIND AT HIS OWN EXPENSE. PENETRATIONS 1582 PLUMBING PIPING A UNIFORM SLOPE OF NOT LESS THAN 1/8" PER FOOT FOR PIPING 4" OR LARGER, AND NOT FIXTURES OF SAME MANUFACTURER WHERE POSSIBLE. Client i2J24/2015 o) W LESS THAN 1/4" PER FOOT FOR PIPING 3" OR SMALLER. LAY PIPE AT UNIFORM SLOPE, FREE 3 N N FROM SAGS WITH HUB END UPSTREA n I 2 2015 M Q KEEP PREMISES BROOM CLEAN OF FOREIGN MATERIAL CREATED UNDER THIS CONTRACT. SEAL FLOOR, EXTERIOR WALL, AND ROOF PE ETRATIO S WATERTIGHT AND WEATHERTIGHT PIPING MATERIALS M. MAKE CHANGES IN DIRECTION FROM HORIZONTAL FIXTURES SHOWN ON THE DRAWINGS OR SPECIFIED HEREIN SHALL BE FURNISHED AND La d Ord�2f 4/ o. O PIPING, EQUIPMENT, ETC. SHALL HAVE A NEAT AND CLEAN APPEARANCE AT THE WITH NON-SHRINK, NON-HARDENING COMMERCIAL SEALANT. PACK WITH MINERAL WOOL TO VERTICAL, AT FIXTURE BRANCHES AND OTHER BRANCH CONNECTIONS WITH SANITARY INSTALLED, SET FIRM AND TRUE, CONNECTED TO REQUIRED PIPING SERVICES, THOROUGHLY N a TERMINATION OF THE WORK. AND SEAL BOTH ENDS WITH MINIMUM OF 1/2" OF SEALANT. MATERIALS SPECIFIED OR NOTED ON THE DRAWINGS ARE SUBJECT TO THE APPROVAL OF "TEES" OR SHORT SWEEP "ELLS". MAKE CHANGES IN DIRECTION FROM VERTICAL TO CLEANED, LEFT CLEAN AND READY FOR USE. EXPOSED FITTINGS AND PIPING AT THE FIXTURES Permit; /2442015 M LOCAL CODE AUTHORITIES. VERIFY APPROVAL BEFORE INSTALLING ANY MATERIAL OR HORIZONTAL OR HORIZONTAL TO HORIZONTAL WITH LONG RADIUS FITTINGS, LONG SHALL BE CHROME-PLATED, AND WATER SUPPLY PIPING SHALL BE VALVED AT EACH FIXTURE. Bid: 0 T RING NSTRU TION WHEN NOT IN FIRE RATED ASSEMBLIES. COORDINATE FIR RATIN A SWEEPING ELLS COMBINATION 'Y AND 1 8 BEND" FITTINGS 0 4 "EL o Z PLUG OR CAP OPEN ENDS OF PIPING SYS EMS DU CO C USE, SEAL AROUND PENETRATIONS OF E GS ND JOINING METHOD. / R 5 DEGREE LS (1/8 N O TO PREVENT THE ENTRANCE OF DEBRIS INTO THE SYSTEMS. LOCATIONS WITH THE ARCHITECTURAL DRAWINGS. REFER TO ARCHITECTURAL BEND FITTINGS), 1/6 BEND OR 1/16 BEND AND -"' FITTINGS. INSTALL PIPE WITH THE BARREL VITREOUS CHINA FIXTURES SHALL BE OF THE BEST GRADE VITREOUS WARE, WITHOUT PIT Construction• C9 SPECIFICATIONS FOR FIRE STOPPINGS. PROVIDE A PRODUCT SCHEDULE FOR UL LISTING, DOMESTIC WATER (COLD AND HOT WATER): DOMESTIC WATER PIPING INSTALLED ABOVE OF THE PIPE ON FIRM, SOLID EARTH FOR ITS ENTIRE LENGTH, AND EXCAVATE HOLES FOR THE HOLES OR BLEMISHES, AND THE OUTLINES SHALL BE GENERALLY TRUE. THE ENGINEER RevlSlonlsuw. E KEEP THE MANUFACTURER-PROVIDED PROTECTIVE COVERINGS ON FLOOR DRAINS, FLOOR LOCATION, WALL OR FLOOR RATING AND INSTALLATION DRAWING FOR EACH PENETRATION THE FLOOR SLAB INSIDE THE BUILDING SHALL BE TYPE "L" HARD TEMPER COPPER TUBE WITH PIPE BELLS. LAY PIPE IN A STRAIGHT LINE AND INSTALL WITH UNIFORM GRADE TO LINE WITH RESERVES THE RIGHT TO REJECT ANY PIECES WHICH, IN HIS OPINION, ARE FAULTY. FIXTURES c=am SINKS AND TRENCH DRAINS DURING CONSTRUCTION. REMOVE COVERINGS AT THE FIRE STOP SYSTEM. WROUGHT COPPER FITTINGS AND SOLDERED CONNECTIONS MADE UP WITH 95/5 SOLDER. BATTEN BOARDS SET NOT MORE THAN 24'-0" APART. CLOSE OPEN ENDS OF PIPE WITH A SET AGAINST WALLS SHALL HAVE GROUND BACKS AND SHALL BE CAULKED WITH SILICONE No. Date DesaQtian r1 Q TERMINATION OF THE WORK AND POLISH EXPOSED SURFACES. BRAZED MECHANICALLY FORMED TEE CONNECTIONS (T-DRILL) MAY BE USED IN COPPER STOPPER WHEN PIPE LAYING IS NOT IN PROGRESS. CENTER SPIGOTS ACCURATELY IN BELLS SEALANT OF A MATCHING COLOR. 0 0 3 EXTEND PIPE INSULATION FOR INSULATED PIPE THROUGH FLOOR, WALL AND ROOF LINES WHERE APPROVED BY CODE; CONNECTION SHALL BE MADE WITH BRAZED SILVER FOR UNIFORM CAULKING. PROVIDE A SMOOTH AND UNIFORM INVERT IN THE SYSTEM. W I SUBSTITUTIONS PENETRATIONS, INCLUDING FIRE RATED WALLS AND FLOORS. THE VAPOR BARRIER SHALL BE SOLDER (SILFOS) JOINTS IN CONFORMANCE WITH MANUFACTURER'S INSTRUCTIONS. DRILLING OR TAPPING OF SOIL AND WASTE LINES, AND SADDLE HUBS AND BANDS ARE NOT PLUMBING FIXTURE TRIM MAINTAINED. SIZE SLEEVE FOR A MINIMUM OF 1" ANNULAR CLEAR SPACE BETWEEN INSIDE PERMITTED. LOCATE AND INSTALL SOIL AND WASTE LINES AS INDICATED ON THE DRAWINGS. '� THE BASE BID SHALL INCLUDE ONLY THE PRODUCTS FROM MANUFACTURERS SPECIFICALLY OF SLEEVE AND OUTSIDE OF INSULATION. INTERIOR WASTE AND VENT BELOW SLAB: WASTE AND VENT PIPE BELOW SLAB INSIDE DETERMINE EXACT LOCATIONS IN SUCH A MANNER AS TO MAINTAIN PROPER CLEARANCE. SUBMIT CERTIFICATION THAT FAUCETS AND TRIM COMPLY WITH NSF 61 ANNEX G AND / OR m NAMED IN THE DRAWINGS AND SPECIFICATIONS. NO SUBSTITUTION WILL BE CONSIDERED BUILDING SHALL BE SERVICE WEIGHT CAST IRON SOIL PIPE WITH HUB AND SPIGOT FITTINGS PRIOR TO INSTALLATION OF ANY BUILDING DRAIN PIPE, VERIFY ELEVATION OF CONNECTION NSF 372. � N PRIOR TO RECEIPT OF BIDS UNLESS WRITTEN REQUEST FOR APPROVAL TO BID HAS BEEN SEAL CONCRETE OR MASONRY EXTERIOR WALL PENETRATIONS BELOW GRADE WITH 'WALL WITH NEOPRENE GASKET JOINTS, MEETING ASTM A74, MANUFACTURED BY AB & I FOUNDRY, POINT OF EXISTING SEWER, SERVICE LINE, OR EXISTING TENANT CONNECTIONS INDICATED a� u7 RECEIVED BY THE ENGINEER AT LEAST TEN CALENDAR DAYS PRIOR TO THE DATE FOR RECEIPT PIPES" AND MECHANICAL SLEEVE SEALS. PROVIDE CAST IRON "WALL PIPES" WITH INTEGRAL CHARLOTTE OR TYLER PIPE AND BEARING THE TRADEMARK OF THE CISPI AND NSF. HUBLESS ON THE DRAWINGS. IF THE INSTALLATION WILL NOT TIE INTO THE INDICATED INVERT FIXTURE TRIM SHALL HAVE THE MANUFACTURER'S NAME STAMPED CLEARLY AND VISIBLY ON c M OF BIDS. EACH SUCH REQUEST SHALL INCLUDE THE NAME OF THE MATERIAL OR EQUIPMENT WATERSTOP RING MANUFACTURED BY JOSAM, JAY R. SMITH, WADE, WATTS OR ZURN. WASTE AND VENT PIPE IS NOT PERMITTED BELOW BASE SLAB. PVC SCHEDULE 40 DWV ASTM ELEVATION POINT WHILE MAINTAINING PROPER FALL, NOTIFY ARCHITECT SO THAT AN EACH ITEM. rn O FOR WHICH IT IS TO BE SUBSTITUTED AND A COMPLETE DESCRIPTION OF THE PROPOSED PROVIDE MODULAR MECHANICAL SLEEVE SEALS, MANUFACTURED BY THUNDERLINE / LINK D2665 PIPE WITH PVC MEETING ASTM 81784, "SOLID WALL" CELL CLASS 12454—B WITH ASTM ALTERNATIVE MAY BE DETERMINED. c SUBSTITUTE INCLUDING DRAWINGS, CUTS, PERFORMANCE AND TEST DATA, AND OTHER SEAL, CALPICO, INC. AND METRAFLEX. 2665 SOCKET FITTINGS WITH SOLVENT WELD JOINTS IS ALSO PERMITTED WHERE APPROVED o, � INFORMATION NECESSARY FOR AN EVALUATION. A STATEMENT SETTING FORTH CHANGES IN BY CODE. s OTHER MATERIALS, EQUIPMENT OR OTHER WORK THAT INCORPORATION OF THE a' / SUBSTITUTE WOULD REQUIRE SHALL BE INCLUDED. THE BURDEN OF PROOF OF THE MERIT ZO OF THE PROPOSED SUBSTITUTE IS UPON THE PROPOSER. THE ENGINEER'S DECISION OF � N APPROVAL OR DISAPPROVAL TO BID OF A PROPOSED SUBSTITUTION SHALL BE FINAL. N Q�'J N / a N o cD Lo U) o �. N LLI > J O N _j 0 wingNumbec (3 � LEED NOTES PROVIDED IN BOXES FOR CLARITY a � o J Z a _J x = / c � 17 OF 31 MECHANICAL SYMBOLS (ONROOF) O 1 M2 THISNECISARILMA TED E ENDEAND NOGS. LL SYMBOLS, ETC. ARE7OTE7 PIPING r —, GENERAL MECHANICAL NOTES: CD CONDENSATE DRAIN (CD) I I 1. SYSTEM SHALL BE BALANCED BY THIRD PARTY NEBB CERTIFIED ACD AUXILIARY CONDENSATE DRAIN (ACD) I I PERSONNEL. SUBMIT T&B REPORT TO ENGINEER FOR REVIEW. GRUSKIN RL REFRIGERANT LIQUID (RL) L——J 2. SYSTEM SHALL BE BALANCED BY THIRD PARTY NEBB CERTIFIED RD REFRIGERANT DISCHARGE (HOT GAS) (RD) PERSONNEL OTHER THAN ROTH BROS AND INSTALLING CONTRACTOR. 294 Morris Avenue Springfield,NJ 07081 RS REFRIGERANT SUCTION (RS) SUBMIT T&B REPORT TO ENGINEER FOR REVIEW. Tel: 973.376.4411 Fax:973.376.8989 www.GruskinGroup.com NJ REG 0100.9869-N HWS HEATING HOT WATER SUPPLY (HWS) 3. PRIOR TO SUBMITTING BID, VISIT THE JOB SITE AND BECOME FULLY ACQUAINTED WITH — —HWR— — HEATING HOT WATER RETURN (HWR) THE EXISTING CONDITIONS OF THE PROJECT. REVIEW THE GENERAL NOTES, This document and the ideas and designs incorporated SPECIFICATIONS, AND OTHER DRAWINGS FOR ADDITIONAL REQUIREMENTS WHICH herein,as an Instrument of professlonai service, Is the CWS CHILLED WATER SUPPLY (CWS) 6 11 MAY NOT BE SPECIFICALLY CALLED OUT IN THIS PORTION OF THE CONSTRUCTION property of GRUSKIN ARCHITECTURE+DESIGN,P.C.,and —CWR— — CHILLED WATER RETURN (CWR) DOCUMENTS. NOTIFY ARCHITECT, ENGINEER, AND/OR OWNER OF CONFLICTS OR is notwKhouthebe sedinw1ioleorinpan written on for any oN�prokd HS HEAT PUMP SUPPLY (HS) 12 DISCREPANCIES PRIOR TO SUBMISSION OF BID. ARCHttECNRE+DESIGN,P.C. 22x22 All Rights Reserved ---HR--- HEAT PUMP RETURN (HR) CRG1 ¢ 4. EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS AND SITE VISITS AND >, ©2015 Gruskin Architecture+Design,P.C. MAY NOT REFLECT EXACT AS-BUILT CONDITIONS. FIELD VERIFY EXISTING CONDITIONS LPS LOW PRESSURE STEAM SUPPLY (LPS) I 1 1/4 41, cR —1 _�_� PRIOR TO SUBMITTING FINAL BIDS. COORDINATE NEW WORK AND DEMOLITION WITH K�ih JL GrUdd g AIA —LPC— — LOW PRESSURE STEAM CONDENSATE (LPC) II��I® ° OTHER DISCIPLINES AND EXISTING CONDITIONS PRIOR TO CONSTRUCTION. cn N AL 5421 MT 2537 — — — — — EXISTING PIPING TO BE REMOVEDDM6 TELCO 5. ALL MECHANICAL EQUIPMENT SHOWN ON THE MECHANICAL PLANS SHALL BE AK 13167 NC 9961 EXISTING PIPING TO REMAIN 109 PROVIDED BY THE MECHANICAL CONTRACTOR UNLESS OTHERWISE NOTED. AR 3811 ND 1666 AZ DIRECTION OF FLOW N.1.C. 2 6 v RA 8x8 R 5 CA C929898 NH 2796209 NE 47 6. THERMOSTATS SHALL BE LOCATED AND SET BY MECHANICAL CONTRACTOR AND WIRED CO ARC-400347 NJ AI 09999 BALL VALVE I M2 2 I ® - -1 ( IN CONDUIT BY ELECTRICAL CONTRACTOR. THERMOSTATS SHALL BE LABELED WITH CT 9613 NM 004168 �D CONTROL VALVE o ASSOCIATED HVAC UNIT. MOUNTING HEIGHTS SHALL BE 48" AFF TO MEET ADA DC ARC100723 NV 5521 MENS „ REQUIREMENTS UNLESS NOTED OTHERWISE ON PLANS. DE 0006261 NY 025528-1 NY THREE-WAY CONTROL VALVE RESTROOM SD2 - FL AR91629 OK a4895 SHUTOFF VALVE N.I.C. 108 50 2 7 OPERATIONLOFOFANACOOL UNITSLIN ALLDE ALL CONTROL MODES PER SEQUEIRING ETC. FOR NCE OF OPERATION.PER HI AR j�ggg OR 4899OH 1 CHECK VALVE I 1A 05713 PA ID AR-984459 PR 19965 _g d� BALANCING VALVE WITH PRESSURE PORTS I OMEN I 3/ 10"� 8. STRUCTURAL ENGINEERING, BRACING, FRAMES, AND ROOF PENETRATIONS, IF IL 001-019152 RI 2666 REQUIRED, MUST BE DONE BY LANDLORD APPROVED ROOFING CONTRACTOR AT CSD1 IN AR10400066 SC 6834 0.4 TRIPLE DUTY VALVE WITH PRESSURE PORTS STRO — -- J 5 250 CONTRACTOR'S EXPENSE TO MAINTAIN ROOF WARRANTY AND AS REQUIRED BY CITY KS 4674 SD 11532 MANAG E 07 M2 BUILDING INSPECTOR. KY 5967 TN 101374 WATER METER 105 i M2 6"� I CU 1 LA 5734 TX 17680 STRAINER 10 CSD2 2 9. COORDINATE THE INSTALLATION OF THE MECHANICAL SYSTEMS WITH OTHER TRADES ME ARC 2596 LIT 5881358-0301 SOLENOID VALVE 8"QS / 50 TO ENSURE A NEAT AND ORDERLY INSTALLATION. INSTALL DUCTWORK AND PIPING AS MD 11016 Vf 2572 T 1 3 MA 10635 VA 0401 011223 TIGHT TO STRUCTURE AS POSSIBLE. COORDINATE WITH OTHER TRADES TO AVOID PRESSURE GAUGE CSD1 22x10 I a a8 6 rd I MI 1301052379 WA 10344 CONFLICTS. COORDINATE INSTALLATION OF DUCTWORK AND PIPING TO AVOID 150 CRG2 T °°° I _L __ _ �_ N MN 44326 WI 9900-005 THERMOMETER F U 2 ____ _�_ 4---_ �- - +-- 1_1/4" X — CONFLICTS WITH ELECTRICAL PANELS, LIGHTING FIXTURES, ETC. ANY MODIFICATIONS MO A-2005029740 WV 3727 �I�--- UNION — — — — o — REQUIRED DUE TO LACK OF COORDINATION WILL BE THE RESPONSIBILITY OF THE MS 3860 WY C-1967 8"0 - - 1 — x _ _ CONTRACTOR AT NO EXTRA COST TO THE OWNER. FLANGE CONNECTION INVENTORY aroresslose�. — 10. DUCTWORK AND PIPING SHALL BE ROUTED IN THE PLANE 2'-0" ABOVE THE CEILING TO �o ELBOW UP 1O6 6'-0" ABOVE THE CEILING. ROUTE DUCTWORK AS LOW AS POSSIBLE IN THIS PLANE Ep PROF I -- -I EXCEPT AS NEEDED FOR DUCT CROSSINGS AND ROUTING AROUND OTHER TRADES. P e ELBOW DOWN BREAK AREA 8"Sri 22x10 LL-4 LOCATE ALL EQUIPMENT, DAMPERS, AND VALVES THAT NEED ACCESS WITH BOTTOM �5�� NGINEF s'1 TEE UP 1 3 C CRG2 I 1 OF DUCT AT 2'-0" ABOVE THE CEILING. CONTRACTOR SHALL COORDINATE ALL � 9 TEE DOWN EF-3 T 0 D I OPEN OFFICE 8"0 1 O x ROUTING AND HEIGHTS WITH OTHER TRADES, STRUCTURE, AND CEILING HEIGHTS 84242PE ' C. ROOM I CS0 102 0501 I 8x8 CRG1 PRIOR TO FABRICATION OR INSTALLATION. ' HVAC EQUIPMENT & DUCTWORK 1 4 / 8"� I 200 A 1 3 11. REFER TO ARCHITECTURAL PLANS FOR DIFFUSER LOCATIONS. O E AD NOTE: ALL DUCT DIMENSIONS SHOWN ON DRAWINGS ARE INSIDE DIMENSIONS. 2 F �� 18x12 8x8 4 2 SEE SECTION 15250 OF THE SPECIFICATION FOR DUCTWORK TO \1 vil 12. HVAC SYSTEMS AND CONTROLS WILL BE COMMISSIONED PER THE REQUIREMENTS OF 7 � I M2 M2 THE COMMISSIONING SECTION OF THE LEED PROTOTYPE GREEN SPECIFICATIONS. RECEIVE INSULATION OR LINER. M2 RA EXISTING DUCTWORK OR EQUIPMENT TO REMAIN cu-3 13. PRIOR TO COMMENCING WORK ON THE STORE, THE GENERAL CONTRACTOR SHALL TS I % PROVIDE COPIES OF THE COMMISSIONING SPECIFICATIONS ON THE LEED PROTOTYPE EXP RES; 1 1 1 EXISTING DUCTWORK OR EQUIPMENT TO BE REMOVED i _ ,�' GREEN SPECIFICATIONS TO THE MECHANICAL, ELECTRICAL, PLUMBING, AND CONTROLS - - - 2 x 1 RA I SUB—CONTRACTORS. conwira� it BRANCH DUCT WITH 45' RECTANGLE-ROUND BRANCH14.I (TYP 5) \'� -� j FITTING AND MANUAL VOLUME DAMPER I PROVIDE UNIT MOUNTED GFCI CONVENIENCE RECEPTACLE, UNLESS A FUNCTIONING N I I RECEPTACLE IS EXISTING TO REMAIN. 171 ELBOW WITH TURNING VANES I X ` i i X HENDERSON L I � 15. REFER TO SPECIFICATIONS FOR SEISMIC DESIGN REQUIREMENTS. 8„0 8„0 10„o ENGINEERSM JM RETURN, EXHAUST, OR OUTSIDE AIR DUCT UP — I — 1 — — — —CS— — — Di — — — \� 1 1 TS — 8345LENEXADRIVE,SUITE300 EIIL ___ ___ �----� ` LENEXA,K566214 0 I210 , 250 250 9 Trey 913 742 5000 Fax 913 742 5001 RETURN, EXHAUST, OR OUTSIDE AIR DUCT DOWN r � � � � � ,' ��D4 IM SUPPLY AIR DUCT UP i I i ,L___J 1 .4 �� ,;�' � � MECHANICAL PLAN NOTES: www.tie003152 m ___ L___J �v� O � � 1550003152 Ol NEW FCU PROVIDED BY VERIZON CONTRACTOR. VERIFY LOCATION WITH EXISTING rXr r SUPPLY AIR DUCT DOWNi i I I ` ' �v� STRUCTURE. I EQUIPMENT WITH FLEXIBLE DUCT CONNECTION I O2 ROUTE OUTSIDE AIR DUCTWORK HIGH ABOVE CLEARANCE OF FCU. kbNemeandNumber. 2015'0131 10” CSD-1 300 CFM -i i IF] 0 F= 0 i ° O3 PROVIDE MINIMUM MERV-13 FILTERS. Proposed NECK SIZE, TYPE, CFM OF SUPPLY DIFFUSER OR REGISTER I RETAIL SALES �, 4 CONNECT OUTSIDE AIR TO FAN COIL UNIT WITH BALANCING DAMPER. MOTORIZED 101 ©' ( ( O DAMPER SHALL BE SET TO MINIMUM OUTSIDE AIR CFM FOR ALL UNITS. INTERLOCK VERIZON MANUAL VOLUME DAMPER I I T�`� D MOTORIZED DAMPER WITH FCU-1. , , I ` 1 2x 12 O x12 r STO R E SQUARE TO ROUND TRANSITION i I E'�T- �� '' I O5 MOUNT COMPUTER ROOM UNIT (CRU-1) AT SHOWN LOCATION ABOVE DOOR. EXTEND `� I ,' `� I REFRIGERANT PIPING FROM CRU-1 THRU ROOF TO CU-1. SIZE PIPING PER DUCT MOUNTED SMOKE DETECTOR -� � -------- (LEED)RD (SD=SUPPLY/RD=RETURN) ________ MANUFACTURER'S REQUIREMENTS. REFER TO SPECIFICATIONS. © NEW EXHAUST FAN AND ASSOCIATED DUCTWORK AND AIR DEVICES PROVIDED BY 1 SD I VERIZON CONTRACTOR. INSTALL FAN DISCHARGE AT MINIMUM OF 15'-0” FROM ANY FD FIRE DAMPER CO2 CARBON DIOXIDE SENSOR I CSD1 250 I OUTSIDE AIR INTAKES AND 2'-0” FROM ANY OTHER ROOF MOUNTED EQUIPMENT. FSD FIRE SMOKE DAMPER HS HUMIDITY SENSOR FIELD VERIFY EXACT LOCATION. SD SMOKE DAMPER PS PULL STATION i CSD1C 'D1 ( O7 NEIN EXHAUST FAN AND ASSOCIATED DUCTWORK AND AIR DEVICES PROVIDED BY Job Address // \\ 210 �00 �' \\ i I VERIZON CONTRACTOR. DISCHARGE FAN ABOVE ADJACENT PLENUM. Washington Square Mail VD VOLUME DAMPER SP STATIC PRESSURE SENSOR i / \\ \ ® ARCHITECT TO PROVIDE 16x16 LOUVERED OPENING IN DOOR FOR AIR PASSAGE, AND OI \ DOOR SHALL BE UNDERCUT ,". SquareRoaWashington MD MOTORIZED DAMPER TS TEMPERATURE SENSOR � � ��.' `✓' �\ BD BACKDRAFr DAMPER OH HUMIDISTAT I / o ,' \ �� ©�' O9 PROVIDE REMOTE TEMPERATURE SENSOR WITH AN OCCUPANT ADJUSTABLE SPACE Portland OR 97223 3 , % O TEMPERATURE OF +/- 2 'F. I X I Space ROHM N OT THERMOSTAT I / / u ( �\ ( I 10 LOCATE 7-DAY PROGRAMMABLE THERMOSTAT IN MANAGER ROOM 105 OR OPEN ,o ( O I OFFICE 102 AS APPLICABLE. THERMOSTATS SHALL BE LABELED WITH ASSOCIATED UNIT. W) ABBREVIATIONS '�� �' �'` I REFER TO SPECIFICATIONS. DrawlagUhr O I p AFF ABOVE FINISHED FLOOR Mc MECHANICAL CONTRACTOR `� 4 �� ,' I 11 CONNECT TO CHILLED WATER SUPPLY/RETURN OF EQUAL OR GREATER SIZE. MECHANICAL PLAN > Ln BAS BUILDING AUTOMATION SYSTEM MIN MINIMUM ( `� ,' j BD BACKDRAFT DAMPER NC NOISE CRITERIA I ' M2 �' I COORDINATE EXACT LOCATION IN FIELD. CFM CUBIC FEET PER MINUTE CA OUTSIDE AIR ( (TYP) I I 12 CONNECT OUTSIDE AIR DUCT TO COMMON MALL OUTSIDE AIR DUCTWORK. VERIFY a DDC DIRECT DIGITAL CONTROL RA RETURN AIR 8"� `— C, 10"0 10"o LOCATION ON SITE. g / DX DIRECT EXPANSION SA SUPPLY AIR CSD1 CSD1 CSD1 CSD1 a 0I 210 210 250 250 00 p EA EXHAUST AIR SD SMOKE DUCT DETECTOR m W FFA FROM FLOOR ABOVE TFA TO FLOOR ABOVE 0 FFB FROM FLOOR BELOW TFB TO FLOOR BELOW I I GPM GALLONS PER MINUTE TYP TYPICAL I Drawn By. Nonh C43 0 IN WC INCHES OF WATER COLUMN LINO UNLESS NOTED OTHERWISE a MAX MAXIMUM W/ WITH Checked 0 F MBH 1000 BTU PER HOUR W/O WITHOUT 3 STANDARD MOUNTING HEIGHTS _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Client i2_424./20i5 or 04 0r MECHANICAL (AFF, AFG, UNLESS NOTED OTHERWISE) I Permit�2f24/2015 N Landlord; /24/2 5 Cl) THERMOSTATS (USER ADJUSTABLE) 48" Bid: oCONTROLS (CENTERLINE) 48" — — — — — — — — — — — — — — — — — — — — — — — Construction: Revision Issue: 4 ANNOTATION Nn. oesapuan c 3 C. O MECHANICAL PLAN CALLOUT 0 I e MECHANICAL EQUIPMENT DESIGNATION (CONTRACTOR FURNISHED . AND INSTALLED UNLESS NOTED OTHERWISE) eq m t� & CONNECTION POINT OF NEW WORK TO EXISTING 0 1 DETAIL REFERENCE UPPER NUMBER INDICATES DETAIL NUMBER &SCA ECHANICAL PLAN N 0 �LID M1 LOWER NUMBER INDICATES SHEET NUMBER LE: 1 1 '-0" i N M1 SECTION CUT DESIGNATION o N caN LEED NOTES PROVIDED IN BOXES FOR CLARITY N W DrawingNumber: c > —J O a MECHANICAL CODE: cn 2014 OREGON MECHANICAL SPECIALTY CODE (2012 IMC) X = / a) 18 OF 31 J_ 7 FAN COIL UNIT SCHEDULE (HYDRONIC COOLING WITH ELECTRIC HEAT) MARK MANUFACTURER MODEL SUPPLY FAN COOLING COIL HEATING COIL MIN. ELECTRICAL WEIGHT NOTES CFM IMIN. ESP TSP TH SH EAT LAT GPM EWT LWT ROWS MAX. MAX. VEL. MIN. OUT. NOMINAL STAGES 0/A VPH MCA MOCP DISC. STARTER LBS HP IN IN MBH MBH DB WB DB WB 'F 'F FPI WPD FT FPM MBH KW CFM TYPE TYPE FCU-1 JCI AHI-12 1,250 0.75 0.6 1.64 35.9 31.9 77.7 62.9 55 54 4.8 44 59 6 10.0 400 41.2 12.0 2 285 460/3 21 25 NF FVNR 303 A-P FCU-2 JCI AHI-12 1,250 0.75 0.6 1.64 35.9 31.9 77.7 62.9 55 54 4.8 44 59 6 10.0 400 41.2 12.0 2 285 460/3 21 25 NF FVNR 303 A-P SUPPORT DRAIN PAN FROM HANG FAN COIL UNIT FROM FCU-3 JCI AHI-08 1,000 0.75 0.5 1.64 28.3 25.2 77.5 62.8 55 54 3.8 44 59 6 10.0 400 32.7 10.0 2 115 460/3 17 20 NF FVNR 269 A-P STRUCTURE INDEPENDENT STRUCTURE WITH SPRING GRUSKIN OF FAN COIL UNIT. VIBRATION ISOLATORS AND MODEL NUMBERS SHALL NOT BE CONSIDERED COMPLETE AND MATERIAL SHALL NOT BE ORDERED BY MANUFACTURER AND MODEL NUMBERS ONLY. REVIEW THE COMPLETE DESCRIPTION, NOTES AND STRUCTURE ALL-THREAD ROD. SPECIFICATIONS TO DETERMINE THE EXACT MATERIAL AND ACCESSORIES TO BE ORDERED. THE MANUFACTURERS LISTED ARE THE BASIS FOR THE DESIGN. 294 Morris Avenue Springfield,Nj 07081 OUTSIDE NOTES Tel: 973.376.441 1 Fax:973.376.8989 AIR DUCT NOTE 3 www.GruskinGroup.com NJ REGo1049869-14 MANUAL A. EQUIPMENT COMPONENTS SHALL BE BY THE SAME MANUFACTURER. This document and the ideas and designs incorporated VENT B. EQUIPMENT SIZED FOR 95' F AMBIENT TEMPERATURE. herein,as an Instrument of professional service, Is the �� 11 C. NOT USED. property of GRUSKIN ARCHITECTURE+DESIGN,P.C.,and FLEXIBLE CONNECTORS (TYP) is not to be used in whole or in part for any other project D. PROVIDE UNIT WITH HIGH EFFICIENCY FILTER BANK AND MINIMUM MERV 13 FILTER. without the written authalzationof GRUSKIN NOTE 3 MD SUPPLY AIR DUCT E. PROVIDE WITH 7-DAY PROGRAMMABLE THERMOSTAT WITH STAGED HEATING AND COOLING CAPABILITY AS REQUIRED FOR OPERATION OF AUXILIARY HEATING AND COOLING CONTROLS. ARCHITECTURE+DESIGN,P.C. F. PROVIDE FACTORY MOUNTED DISCONNECT INSTALLED ON SERVICE SIDE OF UNIT. All RWAs Reserved FAN - G. STARTER FURNISHED BY DIVISION 21 CONTRACTOR. ©2015GruskinArchitecture+Design,P.C. -f- COIL = -+- H. PROVIDE SINGLE POINT POWER CONNECTION. J. PROVIDE WITH SPRING VIBRATION ISOLATION AND ALL-THREAD HANGING RODS. K�1h A GuM MA K. SPECIFIED FAN ESP ACCOUNTS FOR DUCT LOSSES EXTERNAL TO UNIT. AL 5421 MT 2537 PROVIDE AUXILIARY DRAIN AN, L. SPECIFIED FAN TSP INCLUDES EXTERNAL DUCT AND INTERNAL FILTER, COIL AND CASING LOSSES. FILTER LOSS IS AT MAXIMUM 400 FPM. AK 13167 NC 9961 RETURN SEE NOTE 4 M. SELECT EQUIPMENT FOR ELEVATION OF 230 FEET ABOVE SEA LEVEL. AR 3811 ND 1666 AIR DUCTJ AZ 39209 NE A-3547 N. PROVIDE AUXILIARY DRAIN PAN WITH FLOAT SWITCH TO SHUT OFF UNIT WHEN WATER IS PRESENT IN DRAIN PAN. CA C-29898 NH 2796 0. PROVIDE HEATER TO MEET OR EXCEED SCHEDULED MINIMUM MBH OUTPUT. NOMINAL KW IS BASED ON LISTED MANUFACTURER?S STANDARD PRODUCT. CO ARC-400347 NJ AI 09999 DRAIN VALVE (TYP.) AUXILIARY CONDENSATE DRAIN P. COORDINATE EQUIPMENT POWER SUPPLY WITH ELECTRICAL CONTRACTOR IF DIFFERENT FROM THAT SCHEDULED. CT 9613 NM 004168 RE: PLUMBING DRAWINGS DC ARC100723 NV 5521 DE 0006261 NY 025528-1 NY �CHWR CONDENSATE DRAIN AND P-TRAP FL AR91629 OK a4895 CONTROL VALVE (TYP.) RE: PLUMBING DRAWINGS GA M011075 OH 13761 �CHWS 4899 _j PROVIDE FLOAT SWITCH. SEE NOTE 5. COMPUTER ROOM UNIT SCHEDULE HI AR 11489 OR RA- IA 05713 -0 5432-8 NOTES: ID AR-984459 PR 19965 1. ARRANGEMENT SHOWN IS SCHEMATIC, ADJUST TO SUIT FIELD CONDITIONS OR MEET MARK MANUFACTURER MODEL REFR. EVAPORATOR SECTION CONDENSING SECTION EFF. NOTES IL 001-019152 RI 2666 LOCAL CODE REQUIREMENTS. TYPE AIRFLOW TC EAT V/PH MCA / MOCP FLA AMB V/PH MCA / MOCP (SEER) IN AR10400066 SC 6834 2. SIZE CONTROL VALVE FOR MAXIMUM PRESSURE DROP OF 5 PSIG BUT NOT LESS CFM MBH DB WB F KS 4674 SD 11532 THAN 1/2 INCH. CRU-1/CU-1 MITSUBISHI MSVMUY-GE12NA R-41 DA 388 12.0 75/62 208/1 1/15 1 100 208/1 12/15 20.5 A-E LA KY 5967 TN 101374 3. INTERLOCK 2-POSITION MOTORIZED OUTDOOR AIR DAMPER WITH FCU-1 TO OPEN E ARC2596UT 5881TX 8358-0301 WHEN FAN STARTS IN OCCUPIED MODE. SET OPEN POSITION TO MINIMUM MODEL NUMBERS SHALL NOT BE CONSIDERED COMPLETE AND MATERIAL SHALL NOT BE ORDERED BY MANUFACTURER AND MODEL NUMBERS ONLY. REVIEW THE MD 11016 VT 2572 OUTSIDE AIR VENTILATION CFM SCHEDULED FOR ALL FAN COIL UNITS. MA 10635 VA 0401 011223 COMPLETE DESCRIPTION, NOTES AND SPECIFICATIONS TO DETERMINE THE EXACT MATERIAL AND ACCESSORIES TO BE ORDERED. THE MANUFACTURERS LISTED MI 1301052379 WA 10344 4. EXTEND AUXILIARY DRAIN PAN MINIMUM 3" BEYOND UNIT ON ALL SIDES. ARE THE BASIS FOR THE DESIGN. MN 44326 WI 9900-005 5. PROVIDE FLOAT SWITCH IN 1/2" COUPLING 1" ABOVE BOTTOM OF DRAIN PAN. MO A-2005029740 WV 3727 INTERLOCK FLOAT SWITCH TO TURN OFF UNIT WHEN WATER IS PRESENT. NOTES: MS 3860 WY C-1967 6. BALANCE TO MINIMUM OUTSIDE AIR SCHEDULED FOR ASSOCIATED FAN COIL UNIT. Professtonlseal: PIPING. INSTALL REFRIGERANT A. CONTRACTOR SHALL VERIFY WITH EQUIPMENT SUPPLIER EXACT ROUTING AND SIZE OF INSULATED x£. w. . �a>:s 4< �4e PER MANUFACTURERS RECOMMENDATIONS. F FAN COIL L UNIT D h.£,. R 0 ETAIL � :.�:.: F _ F N CONDENSING SECTION. B. DIVISION 16 CONTRACTOR TO PROVIDE DISCONNECT SWITCH FOR EVAPORATOR SECTION AND C J G IN 1 � . NO SCALE F t. E't .:...:::::::::::::::::::..�::;::::. ............. . �................ C. PROVIDE WITH WALL MOUNTED THERMOSTAT BY UNIT MANUFACTURER. �. r 't:........:is -a 4 D. PROVIDE WITH INTEGRAL CONDENSATE PUMP. ' 242P E :Y. r iI tt ..\"'es:<::esssnns:cssss:yssvtt'::.. 0.,..:l It, .l: �......:.....:........:..:.. ............................ .....................�,\E,,.......................»,.•s::,:........:.,. ..... ...»..:..::: A ENERGY STAR LED E. PACKAGED UNITARY HVAC EQUIPMENT SHALL BE ENE G LASE MITSUBISHI CONDENSING UNIT .::$... �.i ennnnns: •s£::`'s:;•is:;•snns4:i4:G:;;""'• v.:sns:;4css,: f� tt� d ..::...:..::::.:':;i.s:a:;.,, , : ,,...:..:.:. �.s..:.:::.i£s;.tv',..`„i's%a•::iiiii;ssssss;;:.;s>?:s:;.::::::..,;:::'.:...; 6£;c E ON O ��\4:i5i::i::i::i::i::isr,.:{•,s$�':6:\1`t:FSi:::i::i::i::i';o ..............., ,.�.s,:asssss:.s:is„^:.::f'£vi::nr:::.s.::.v.:.. ...,s::,......, •� , > < »> GRILLE, REGISTER, AND DIFFUSER SCHEDULE w ;£; MARK SERVICE MANUFACTURER MODEL FACE MOUNTING FACE SIZE MAX NOTES TYPE (IN) NC EX I ES: 1 / 1 : '�" • �' CSD-1 SUPPLY TIT OMNIPLAQUE LAY IN 24x24 30 A-F consultant k: CSD-2 SUPPLY TITUS OMNI PLAQUE LAY IN 12x12 30 A F - x 4 30 A- - CSD-3 SUPPLY TIT OMNI PLAQUE LAY IN 24 2 C E G Q ELECTRICAL •• ° , :, ;t::" r' k r x WIRING BY >',', ::: .k ; CSD-4 SUPPLY TITUS ML-TZ SLOT LAY IN 48" LONG, (3) 3/4" SLOTS 30 A,C,D,E,L R. ;� HENDER N ELECTRICAL �i�`"�:>:::��;>:' >.� '::..:>< .:;�>`>1 SO ALL-THREAD ROD CONTRACTOR £:."' ; .: ;;:' ENGINEERSN TO STRUCTURE .�"`�"` �_�_>'_» ;�»»>! CRG-1 RETURN TITUS 350FL LOUVERED LAY IN 24x24 30 A,C-F,H 8345 LENEXADRNE SUfiE 300 ` CRG 2 RETURN TITUS 350FL LOUVERED LAY IN 24x1 2 30 A C-F J EXHAUST DUCT _ " `<=E::»: LENEXA,KS 66214 " ' \ ::"' CRG-3 RETURN TITUS 350FL LOUVERED LAY IN 12x12 30 A,C-F,K RE: MECHANICAL PLAN .:>:... :x<:>;:.::..: „s,.N':..,;,., �` �}'.;;;,� TEL 913142 5000 Fax 913142 5001 3 www.hei-eng.com BACKDRAFT af �P {" A; 3� £i� � ° � 1550003152 FAN HOUSING t< m. 4� ger rf �� ` tt , � ;.:'` MODEL NUMBERS SHALL NOT BE CONSIDERED COMPLETE AND MATERIAL SHALL NOT BE ORDERED BY MANUFACTURER AND MODEL NUMBERS ONLY. DAMPER a k4 A, REVIEW THE COMPLETE DESCRIPTION, NOTES AND SPECIFICATIONS TO DETERMINE THE EXACT MATERIAL AND ACCESSORIES TO BE ORDERED. '�' .�M�;::.}'�: -8n`s T•..��: y£a:'.#."' .:�.^Dx.�...::.. sk.,:.z9�> :,�;..: � r,,. 7� v *d#., �\� Y THE MANUFACTURERS LISTED ARE THE BASIS FOR THE DESIGN. kb Name and Number 2015-0131 ADJUSTABLE w.. 3.:..`s'.x.-:.,7,., .�`` �. �z�w..l�'.a.f ', �`,' `: Z•t 'eF MOUNTING BRACKETS -�� NOTES: REFRIGERANT PIPING Proposed FLEX CONNECTOR A. NECK SIZE SHOWN ON DRAWINGS. PIPE CURB B. 4-WAY THROW PATTERN UNLESS OTHERWISE SHOWN ON DRAWINGS. VE R IZO N NOTES: C. BRANCH DUCT SIZE SHALL BE SAME AS NECK SIZE UNLESS OTHERWISE SHOWN ON DRAWINGS. STORE INSTALL THE MITSUBISHI CONDENSING UNIT SERVING THE ELEC/TECH CLOSET ON THE FLAT ROOF. INSTALL D. BAKED ENAMEL FINISH, COORDINATE COLOR TO MATCH CEILING COLOR. STO R E ISOLATOR BUSHING CEILING UNIT ON PRE CAST CONCRETE PAVERS ON TOP OF RUBBER CUSHION MATTING. THE PAVERS SHOULD BE E. FRAME TYPE TO MATCH CEILING CONSTRUCTION, COORDINATE WITH ARCHITECTURAL REFLECTED CEILING PLAN. WITH FLANGED NUT EXHAUST GRILLE COORDINATED WITH THE CONDENSING UNIT IN SIZE (APPROXIMATE 3" THICK x 4' LONG x 8" WIDE). USING F. PROVIDE BORDER TYPE TO MATCH CEILING CONSTRUCTION. COORDINATE WITH ARCHITECTURAL REFLECTED CEILING PLAN. (LEED)PROVIDED WITH TAPCON TYPE ANCHORS, ATTACH UNIT TO PAVERS. PROVIDE NEMA 3R DISCONNECT SWITCH. EXTEND G. BAKED ENAMEL FINISH, COLOR SHALL BE BLACK TO MATCH CEILING COLOR. EXHAUST FAN REFRIGERANT PIPING AND LIQUIDTIGHT CONDUIT THROUGH ROOF IN FLASHED ROOF OPENING THROUGH SIDE H. NECK SIZE SHALL BE 22x22. BRANCH DUCT SIZE SHALL BE AS SHOWN ON DRAWINGS. TRANSITION CONNECTION AS NECESSARY TO MATCH. (NO VERTICAL OPENINGS IN THE ROOF OR TAR PITCH POCKETS) THYCURB TP-2 OR APPROVED EQUAL. J. NECK SIZE SHALL BE 22x10. BRANCH DUCT SIZE SHALL BE AS SHOWN ON DRAWINGS. TRANSITION CONNECTION AS NECESSARY TO MATCH. L. PROVIDE BORDER TYPE TO MATCH CEILING CONSTRUCTION WITH CONCEALED MOUNTING AND INSULATED PLENUM WITH NECK. COMPUTER ROOM CONDENSING 2 CEILING MOUNTED EXHAUST FAN 3 UNIT INSTALLATION DETAIL kbMdrm NO SCALE NO SCALE FAN SCHEDULE Washington Square Mall MARK SERVICE MANUFACTURER MOUNTING MODEL AIRFLOW ESP DRIVE MOTOR FAN ELECTRICAL NOTES 9585 S.W. Washington (EA, RA, SA) (CFM) (IN) (BELT/DIRECT) (W) RPM V/PH DISC. TYPE Square Road EF-1 EA COOK CEILING GC-142 75 0.375 DIRECT 54 900 120/1 NF A,B,C,D,F,G,H Portland, OR 97223 a EF-2 EA COOK CEILING GC-142 75 0.375 DIRECT 54 900 120/1 NF A,B,C,D,F,G,H Space R05-R07 N INSTALL MANUAL AIR VENT AT HIGH POINT MV EF-3 EA COOK CEILING GC 215 0.3 DIRECT 100 900 120/1 NF B,C,D,E LO METAL BAND OVER INSULATION (TYPICAL) WHEN TAPPED INTO TOP OF MAINS. USE A 0 PIPE STUB WITH MINIMUM HEIGHT OF 4 MODEL NUMBERS SHALL NOT BE CONSIDERED COMPLETE AND MATERIAL SHALL NOT BE ORDERED BY MANUFACTURER AND MODEL DrawmgTftk 0 HIGH EFFICIENCY TAKEOFF EXTERNALLY INSULATED DUCT PIPE DIAMETERS. (TYP). MV NUMBERS ONLY. REVIEW THE COMPLETE DESCRIPTION, NOTES, AND SPECIFICATIONS TO DETERMINE THE EXACT MATERIAL AND MECHANICAL LO cc INSULATED, WITH VOLUME DAMPER AND ACCESSORIES TO BE ORDERED. THE MANUFACTURERS LISTED ARE THE BASIS FOR THE DESIGN. i DAMPER LOCK WITH EXTENSION MAINS AS SHOWNNNECT TO UON PLAN DETAILS AND c FOIL TAPE AT PRESSURE & TEMPERATURE NOTES: a INSULATION JOINT TEST PLUG (TYP) BALANCING VALVE SCHEDULES g A. DIVISION 21 CONTRACTOR SHALL FURNISH CONTROL RELAY AS REQUIRED TO INTERLOCK FAN WITH LIGHT SWITCHES. a p o UNION (TYP) 0 0 B. PROVIDE WITH INTEGRAL DISCONNECT SWITCH. o SEE NOTE 1. o MANUAL AIR VENT C. PROVIDE WITH INTEGRAL WHITE PLASTIC CEILING GRILLE. N III MV D. PROVIDE WITH RUBBER IN-SHEAR ISOLATORS. PRE-INSULATED FLEXIBLE C E. DIVISION 21 CONTRACTOR SHALL INTERLOCK FAN OPERATION WITH THERMOSTAT. DUCT AS REQUIRED, I I ( F. PROVIDE CURB MOUNTED ROOF CAP (COOK #PR8)WITH 1/2" GALVANIZED STEEL MESH BIRDSCREEN AND BACKDRAFT DAMPER. DrewnBy North N o COIL J TWO-WAY CONTROL G. INSTALL CURB DISCHARGE AT MINIMUM OF 15'-0" FROM ALL OUTSIDE AIR INTAKES. INSTALL PERMANENTLY SEE NOTE 2. Cl) VALVE NORMALLY OPEN CheoedBy: N 0 SEALED AND SUPPORTED H. SELECT EQUIPMENT FOR ELEVATION OF 230 FEET ABOVE SEA LEVEL. i= TO PREVENT KINKING SEE NOTE 3. (SEE NOTE 1) a I AND SHARP TURNS Date Iswed For AIR FLOW ♦ Client 12.124,/2015 Uj N a METAL BAND (TYPICAL) ISOLATION Landlord; VALVE (TYPICAL) OUTSIDE AIR REQUIREMENTS Permit�2,/24J2015 N qq\�\\� ,/ co Bid: AREA NET PEOPLE ASHRAE 62.1-2007 SYSTEM DCV MAX DCV MIN CD M uuu9oo 00000uolo C I PURPOSE FLOOR OUTSIDE AIR NUMBER OUTSIDE AIR OUTSIDE AIR Construction: __� AREA REQUIREMENTS CFM PER UNIT CFM PER UNIT ReNsionIsm& Z COIL DRAIN WITH SQ. FT CFM PER CFM PER Ez CFM FCU-1 285 285 No. Date Desrnptlon CAP AT LOWEST SEE PLANS FOR ( ) o PIPE SIZES. PERSON SQ. FT READ. FCU-2 285 285 0 3 POINT OF COIL 101 RETAIL SALES 2,143 32 7.5 0.12 0.80 621 FCU-3 115 115 I CEILING u 102 WINDOW DISPLAY 0 0 0 0.12 0.80 0 ° NOTES: 103 INVENTORY 150 2 5.0 0.06 0.80 24 1. INSTALL CONTROL VALVE BETWEEN UNIONS OR FLANGES. 104 MANAGER 74 2 5.0 0.06 0.80 18 C-4 2. PROVIDE CONCENTRIC REDUCERS BOTH SIDES OF CONTROL VALVE AS REQUIRED. 105 RESTROOM 1 61 0 0 0 0.80 0 co M NOTES: 3. REPLACE UNION/FLANGE SET WITH A FLEXIBLE PIPE CONNECTOR WHERE 106 RESTROOM 2 61 0 0 0 0.80 0 Cr 0 EQUIPMENT IS SUPPORTED OR SUSPENDED BY SPRING ISOLATORS. 107 J.C. 0 0 0 0 0.80 0 o ro 1. EXTEND RIGID METAL DUCT SO THAT MAXIMUM FLEXIBLE DUCT LENGTH DOES NOT 4. ARRANGEMENT SHOWN FOR FULL FLOW THROUGH COIL ON FAILURE. 108 BACK AREA 689 10 5.0 0.06 0.80 114 Ch LO EXCEED 5'-0". PROVIDE RIGID 90' ELBOW WHERE REQUIRED TO KEEP FLEXIBLE 109 TELCO 60 0 0 0 0.8D 0 DUCT WITHIN 5'-0" LENGTH LIMITATION. 5. PRE-ASSEMBLED HOSE KITS ARE ACCEPTABLE. ALL COMPONENTS SHALL BE ADJUSTMENT FOR VENT. RATE PROCEDURE = 685 ETOTAL 685 685 z INCLUDED AND ARRANGED AS SHOWN. ALL SIZES SHALL BE LINE SIZE EXCEPT 0 CONTROL VALVE MAY BE REDUCED SIZE AS SELECTED BY MANUFACTURER. FLEXIBLE PIPE CONNECTORS SHALL NOT EXCEED 6" LENGTH FOR PIPING > � 1" AND SMALLER OR 12" FOR PIPING OVER 1" IN SIZE. PROJECT DESIGN CONDITIONS N / FAN-COIL UNIT OR REHEAT COIL WITH SPACE COOLING 0.4% WINTER 99% rn d LAY-IN TYPE CEILING DIFFUSER DETAIL TWO-WAY CONTROL VALV�EP IPING DETAIL SERVED MAX. TEMPERATURE COINCIDENT RH % MIN. TEMPERATURE N w T NO SCALE DrawingNumbev: J o NO SCALE OUTSIDE AIR 90.1'F 16.0% 4.8'F N _ SALES 72'F 50% 68'F c� OFFICE 72'F 50% 687 a J TELCO ROOM 707 50% 70'F cc a) 19 OF 31 _J 15A: Heating, Ventilating, and Air Conditioning: PENETRATIONS PIPE CONNECTIONS. PROVIDE FLEXIBLE CONNECTORS FOR PIPING SYSTEM g g: CONTRACTOR SHALL PROVIDE A MINIMUM OF 40 PHOTOGRAPHS (10 EACH WEEK OF CONNECTIONS ON EQUIPMENT SIDE OF SHUTOFF VALVES FOR ALL PUMPS, 15A 1 GENERAL INSTRUCTIONS DIFFERENT ITEMS AND/OR VIEWS) OF CONSTRUCTION IAQ MANAGEMENT MEASURES SUCH SEAL ELEVATED FLOOR, EXTERIOR WALL AND ROOF PENETRATIONS WATERTIGHT AND MECHANICAL EQUIPMENT SUPPORTED OR SUSPENDED BY SPRING ISOLATORS, AS PROTECTION OF DUCTS AND ON—SITE STORED OR INSTALLED ABSORPTIVE MATERIALS. WEATHERTIGHT WITH NON—SHRINK, NON—HARDENING COMMERCIAL SEALANT. PACK WITH AND WHERE INDICATED ON DRAWINGS. FABRICATE FLEXIBLE PIPING GENERAL REQUIREMENTS SEE CONSTRUCTION IAQ MANAGEMENT SPECIFICATIONS PROVIDED ON THE LEED MINERAL WOOL AND SEAL BOTH ENDS WITH MINIMUM OF 1/2" OF SEALANT. CONNECTORS FROM STAINLESS STEEL OR RUBBER MATERIALS AS SUITABLE FOR PROTOTYPE GREEN SPECIFICATIONS FOR MORE INFORMATION. SEAL AROUND PENETRATIONS OF FIRE RATED ASSEMBLIES. COORDINATE FIRE RATINGS SYSTEM FLUID. FLEXIBLE PIPING CONNECTORS SHALL BE BELLOWS, SPHERICAL REQUIREMENTS UNDER DIVISION ONE AND THE GENERAL AND SUPPLEMENTARY AND LOCATIONS WITH THE ARCHITECTURAL DRAWINGS. REFER TO ARCHITECTURAL APPLICATION. HOSE TYPE AS RECOMMENDED BY THE MANUFACTURER FOR THE SUBSTITUTIONS SPECIFICATIONS FOR FIRE STOPPINGS. PROVIDE A PRODUCT SCHEDULE FOR UL LISTING, GRUSKIN CONDITIONS OF THESE SPECIFICATIONS SHALL BE A PART OF THIS SECTION. CONTRACTOR LOCATION, WALL OR FLOOR RATING AND INSTALLATION DRAWING FOR EACH SHALL BECOME THOROUGHLY ACQUAINTED WITH ITS CONTENTS AS TO REQUIREMENTS THE BASE BID SHALL INCLUDE ONLY THE PRODUCTS FROM MANUFACTURERS SPECIFICALLY PENETRATION FIRE STOP SYSTEM. ISOLATOR TYPES THAT AFFECT THIS DIVISION OR SECTION. THE WORK REQUIRED UNDER THIS SECTION NAMED IN THE DRAWINGS AND SPECIFICATIONS. NO SUBSTITUTION WILL BE CONSIDERED INCLUDES MATERIAL, EQUIPMENT, APPLIANCES, TRANSPORTATION, SERVICES, AND LABOR PRIOR TO RECEIPT OF BIDS UNLESS WRITTEN REQUEST FOR APPROVAL TO BID HAS BEEN PROVIDE PREFABRICATED ROOF CURBS MANUFACTURED BY CUSTOM CURB, INC., PATE A. TYPE WP (WAFFLE PADS): PROVIDE 5/16 INCH THICK NEOPRENE PADS RIBBED OR 294 Morris Avenue Springfield,NJ 07081 REQUIRED TO COMPLETE THE ENTIRE SYSTEM AS REQUIRED BY THE DRAWINGS ANDRECEIVED BY THE ENGINEER AT LEAST TEN CALENDAR DAYS PRIOR TO THE DATE FOR COMPANY, THYCURB, OR APPROVED EQUAL. PROVIDE ROOF CURB WITH FACTORY WAFFLED ON BOTH SIDES. MANUFACTURE PADS WITH BRIDGE BEARING QUALITY Tel: 973.376.4411 Fax:973.376.8989 SPECIFICATIONS. RECEIPT OF BIDS. EACH SUCH REQUEST SHALL INCLUDE THE NAME OF THE MATERIAL OR INSTALLED WOOD NAILER; WELDED, 18 GAUGE GALVANIZED STEEL SHELL, BASE PLATE AND NEOPRENE, AND SELECT FORA MAXIMUM DUADING PLATES WHERE OF 50 AND DESIGNED FOR vrww.GruskinGroup.com NJ REG 0100.4864-14 EQUIPMENT FOR WHICH IT IS TO BE SUBSTITUTED AND A COMPLETE DESCRIPTION OF THE FLASHING; 1-1/2" THICK, 3 POUND RIGID INSULATION; FULLY MITERED 3—INCH RAISED 15 PERCENT STRAIN. INCORPORATE STEEL LOAD—SPREADING THE SPECIFICATIONS AND DRAWINGS FOR THE PROJECT ARE COMPLEMENTARY, AND PROPOSED SUBSTITUTE INCLUDING DRAWINGS, CUTS, PERFORMANCE AND TEST DATA, CANT; COVER OF WEATHER—RESISTANT, WEATHER—PROOF MATERIAL AND PIPE COLLAR OF REQUIRED BETWEEN THE EQUIPMENT AND THE NEOPRENE PAD. IF THE ISOLATOR This document and the ideas and designs incorporated PORTIONS OF THE WORK DESCRIBED IN ONE SHALL BE PROVIDED AS IF DESCRIBED IN BOTH. IS BOLTED TO THE STRUCTURE, INSTALL A NEOPRENE VIBRATION ISOLATION herein,as an Instrument of professional service, Is the AND OTHER INFORMATION NECESSARY FOR AN EVALUATION. A STATEMENT SETTING WEATHER—RESISTANT MATERIAL WITH STAINLESS STEEL PIPE CLAMPS. WASHER AND SLEEVE UNIROYAL TYPE 620 660 OR AS APPROVED SHALL BE property of GRUSKIN ARCHnECTURE+DESIGN,P.C.,and IN THE EVENT OF DISCREPANCIES, NOTIFY THE ENGINEER AND REQUEST CLARIFICATION FORTH CHANGES IN OTHER MATERIALS, EQUIPMENT OR OTHER WORK THAT ( / ) isnot to be used in wholeorin partfor any other project PRIOR TO PROCEEDING WITH THE WORK INVOLVED. INCORPORATION OF THE SUBSTITUTE WOULD REQUIRE SHALL BE INCLUDED. THE BURDEN AIR FILTERS INSTALLED UNDER THE BOLT HEAD BETWEEN THE STEEL WASHER AND THE BASE without the wrtttenauthorization of GRUSKIN OF PROOF OF THE MERIT OF THE PROPOSED SUBSTITUTE IS UPON THE PROPOSER. THE PLATE. PROVIDE MASON INDUSTRIES TYPE W OR EQUAL. ARCHITECTURE+DESIGN,P.C. DEFINITIONS ENGINEER'S DECISION OF APPROVAL OR DISAPPROVAL TO BID OF A PROPOSED PROVIDE MINIMUM MERV-13 FILTERS MANUFACTURED BY FARR, AMERICAN AIR FILTER, AIDesi Design, SUBSTITUTION SHALL BE FINAL. FLANDERS, OR APPROVED EQUAL, UNLESS OTHERWISE INDICATED IN OUTSIDE AIR DUCTWORK. B. TYPE SPNH (SPRING AND NEOPRENE HANGERS): PROVIDE A STEEL SPRING IN ©2015GtuskinArchitecture+Design,P.C. FURNISH: THE TERM "FURNISH" IS USED TO MEAN "SUPPLY AND DELIVER TO THE PROJECT AIR UNITS SHALL HAVE NEW FILTERS INSTALLED WHEN THEY ARE OPERATED BEFORE FINAL SERIES WITH A NEOPRENE ISOLATING ELEMENT. THE SPRING SHALL HAVE A SITE, READY FOR UNLOADING, UNPACKING, ASSEMBLY, INSTALLATION AND SIMILAR THE TERMS "APPROVED", "APPROVED EQUAL", AND "EQUAL" REFER TO APPROVAL BY THE ACCEPTANCE. MINIMUM ADDITIONAL TRAVEL TO SOLID EQUAL TO 50 PERCENT OF THE SPECIFIED KWMDM A, GrUdd n NA OPERATIONS." ENGINEER AS AN ACCEPTABLE ALTERNATE BID. NO SUBSTITUTIONS WILL BE CONSIDERED IF HVAC EQUIPMENT IS USED DURING THE CONSTRUCTION PERIOD, CONTRACTOR SHALL DEFLECTION. THE NEOPRENE ELEMENT SHALL HAVE A STATIC DEFLECTION OF NOT LESS THAN 0.3 INCHES WITH A STRAIN NOT EXCEEDING 15 PERCENT. UNLESS AL 5421 MT 2537 THAT ARE NOT BID AS AN ALTERNATE. NO MATERIAL SUBSTITUTIONS SHALL BE PROVIDE MINIMUM MERV-8 FILTERS OVER ALL RETURN GRILLE OPENINGS FOR THE INSTALL: THE TERM "INSTALL" IS USED TO DESCRIBE OPERATIONS AT THE PROJECT SITE OTHERWISE SPECIFIED, THE STATIC DEFLECTION OF SPNH HANGERS SHALL BE 2 AK 13167 NC 9961 CONSIDERED FOR APPROVAL PRIOR TO AWARD OF CONTRACT. DURATION OF THE CONSTRUCTION PERIOD. INCHES. SPRING DIAMETER AND HANGER BOX HOLE SIZE SHALL BE LARGE INCLUDING THE ACTUAL "UNLOADING, UNPACKING, ASSEMBLY, ERECTION, PLACING, AR 3811 ND 1666AZ 39209 NE A-3547 ANCHORING, APPLYING, WORKING TO DIMENSION, FINISHING, CURING, PROTECTING, COORDINATE AND VERIFY WITH OTHER TRADES WHETHER OR NOT THE SUBSTITUTED IF HVAC EQUIPMENT IS USED DURING THE CONSTRUCTION PERIOD, CONTRACTOR SHALL ENOUGH TO PERMIT THE HANGER ROD TO SWING THROUGH A 30 DEGREE ARC. CA C-29898 NH 2796 CLEANING, AND SIMILAR OPERATIONS." EQUIPMENT CAN BE INSTALLED AS SHOWN ON THE CONSTRUCTION DRAWINGS WITHOUT PROVIDE ONE SET OF FILTERS WHEN THE UNIT IS STARTED AND REPLACE FILTERS WHEN PROVIDE NEOPRENE SLEEVE WHERE THE LOWER HANGER ROD PASSES CO ARC-400347 NJ AI 09999 MODIFICATION TO ASSOCIATED SYSTEMS OR ARCHITECTURAL OR ENGINEERING DESIGN. NEEDED, BUT NOT LESS THAN EVERY MONTH. ON THE DAY OF SUBSTANTIAL COMPLETION, THROUGH THE STEEL HANGER BOX, SUCH THAT THE HANGER ROD CANNOT CT 9613 NM 004168 PROVIDE: THE TERM "PROVIDE" MEANS "TO FURNISH AND INSTALL, COMPLETE AND INCLUDE ADDITIONAL COSTS FOR ARCHITECTURAL AND ENGINEERING DESIGN FEES IN BID THE CONTRACTOR SHALL CLEAN THE UNIT AND PROVIDE A NEW SET OF FILTERS IN THE CONTACT THE STEEL HANGER. THE DIAMETER OF THE CLEAR HOLE IN THE DC ARC100723 NV 5521 READY FOR THE INTENDED USE." IF DRAWING MODIFICATIONS ARE REQUIRED BECAUSE OF SUBSTITUTED EQUIPMENT. UNIT. HANGER BOX SHALL BE AT LEAST 3/4 INCH LARGER THAN THE DIAMETER OF THE AR96NY 8-1 NY 629 OK 04895 HANGER ROD. WHEN INSTALLED, DO NOT COCK THE SPRING ELEMENT AND DO FIL GA AR9RA01629 OH 13761 FURNISHED BY OWNER OR FURNISHED BY OTHERS: THE ITEM WILL BE FURNISHED BY THE SUBSTITUTIONS FOR ANY REFRIGERANTS OR EQUIPMENT SHALL BE SUBMITTED AND MOTORS AND STARTERS NOT ALLOW THE HANGER BOX TO ROTATE THROUGH A FULL 360 DEGREE ARC AR 9 HI 11489 OR 489 OWNER OR OTHERS. IT IS TO BE INSTALLED AND CONNECTED UNDER THE REQUIREMENTS APPROVED BY ARCHITECT FOR LEED REQUIREMENTS. SEE REQUIREMENTS FOR WITHOUT ENCOUNTERING OBSTRUCTIONS. PROVIDE MASON INDUSTRIES TYPE IA AIR 13 9 4 2-B OF THIS DIVISION, COMPLETE AND READY FOR OPERATION, INCLUDING ITEMS INCIDENTAL SUBSTITUTIONS ON THE LEED PROTOTYPE GREEN SPECIFICATIONS. PROVIDE MOTORS AND STARTING EQUIPMENT WHERE NOT FURNISHED WITH THE 3ON OR EQUAL. ID AR-984459 PR 19965 TO THE WORK, INCLUDING SERVICES NECESSARY FOR PROPER INSTALLATION AND EQUIPMENT PACKAGE. MOTORS SHALL HAVE COPPER WINDINGS, CLASS B INSULATION, IL 001-019152 RI 2666 OPERATION. THE INSTALLATION SHALL BE INCLUDED UNDER THE GUARANTEE REQUIRED ELECTRONIC DRAWING FILES AND STANDARD SQUIRREL CAGE WITH STARTING TORQUE CHARACTERISTICS SUITABLE FOR C. TYPE SPNM (SPRING AND NEOPRENE MOUNTS): PROVIDE FREE-STANDING AND IN AR10400066 SC 6834 BY THIS DIVISION. THE EQUIPMENT SERVED. MOTORS FOR AIR HANDLING EQUIPMENT SHALL BE SELECTED LATERALLY STABLE STEEL SPRING WITHOUT A HOUSING. DESIGN SPRINGS SO KS 4674 SD 11532 IN PREPARATION OF SHOP DRAWINGS OR RECORD DRAWINGS, CONTRACTOR MAY, AT HIS FOR QUIET OPERATION. EACH MOTOR SHALL BE CHECKED FOR PROPER ROTATION AFTER THE RATIO OF THE HORIZONTAL TO VERTICAL SPRING CONSTANT IS BETWEEN KY 5967 TN 101374 ONE AND TWO. THE SPRING DIAMETER SHALL BE NOT LESS THAN 80% OF THE LA 5734 TX 17680 ENGINEER: WHERE REFERENCED IN THIS DIVISION, "ENGINEER" IS THE ENGINEER OF OPTION, OBTAIN ELECTRONIC DRAWING FILES IN AUTOCAD OR DXF FORMAT ON 3.5 INCH ELECTRICAL CONNECTION HAS BEEN COMPLETED. PROVIDE DRIPPROOF ENCLOSURE FOR COMPRESSED HEIGHT OF THE SPRING AT RATED LOADLOADED SPRINGS SHALL ME ARC 2596 UT 5881358-0301 . RECORD AND THE DESIGN PROFESSIONAL FOR THE WORK UNDER THIS DIVISION, AND IS A FLOPPY DISK, 100 MB ZIP DISK OR CD-ROM DISK, AS DESIRED, FROM THE ENGINEER FOR A LOCATIONS PROTECTED FROM WEATHER AND NOT IN AIR STREAM OF FAN; AND TOTALLY MD 11016 Vi 2572 CONSULTANT TO, AND AN AUTHORIZED REPRESENTATIVE OF, THE ARCHITECT, AS DEFINED SHIPPING AND HANDLING FEE OF $200 FOR A DRAWING SET UP TO 12 SHEETS AND $15 PER ENCLOSED FAN COOLED ENCLOSURE FOR MOTORS EXPOSED TO WEATHER. MOTORS SHALL HAVE A MINIMUM ADDITIONAL TRAVEL TO SOLID EQUAL TO 50% OF THE SPECIFIED MA 10535 VA 0401 011223 IN THE GENERAL AND/OR SUPPLEMENTARY CONDITIONS. WHEN USED IN THIS DIVISION, IT SHEET FOR EACH ADDITIONAL SHEET. CONTRACTOR SHALL CONTACT THE ARCHITECT FOR STATIC DEFLECTION. UNLESS OTHERWISE SPECIFIED, THE MINIMUM STATIC MI 1301052379 WA 10344 / BE MANUFACTURED BY CENTURY, GENERAL ELECTRIC, WESTINGHOUSE, LOUIS ALLIS, OR MEANS INCREASED INVOLVEMENT BY, AND OBLIGATIONS T0, THE ENGINEER, IN ADDITION WRITTEN AUTHORIZATION AND ENGINEER FOR THE NECESSARY RELEASE AGREEMENT APPROVED EQUAL. DEFLECTION OF SPNM ISOLATORS FOR EQUIPMENT MOUNTED ON GRADE SLABS MN 44326 WI 9900-005 TO INVOLVEMENT BY, AND OBLIGATIONS TO, THE "ARCHITECT". FORM AND TO SPECIFY SHIPPING METHOD AND DRAWING FORMAT. IN ADDITION TO SHALL BE 1 INCH, AND THE MINIMUM STATIC DEFLECTION FOR EQUIPMENT MO A-2005029740 WV 3727 PAYMENT, ARCHITECT'S WRITTEN AUTHORIZATION AND ENGINEER'S RELEASE AGREEMENT PROVIDE EVERY MOTOR, EXCEPT FRACTIONAL HORSEPOWER SINGLE PHASE MOTORS WITH MOUNTED ABOVE GRADE LEVEL SHALL BE 2 INCHES. BOND TWO TYPE WP MS 3860 WY C-1967 AHJ: THE LOCAL CODE AND/OR INSPECTION AGENCY (AUTHORITY) HAVING JURISDICTION FORM MUST BE RECEIVED BEFORE ELECTRONIC DRAWING FILES WILL BE SENT. AN APPROVED TYPE OF "BUILT-IN" THERMAL OVERLOAD PROTECTION, WITH A MOTOR ISOLATION PADS SANDWICHING A 16 GAUGE STAINLESS OR GALVANIZED STEEL ProfesslanalSed: OVER THE WORK. STARTER. EACH STARTER SHALL BE PROVIDED WITH OVERLOAD HEATERS SIZED TO THE SEPARATOR PLATE TO THE ISOLATOR BASEPLATE. UNLESS OTHERWISE OPERATION AND MAINTENANCE INSTRUCTIONS MOTOR RATING, AND EVERY THREE PHASE MOTOR STARTER SHALL HAVE OVERLOAD SPECIFIED, ISOLATORS NEED NOT BE BOLTED TO THE FLOOR FOR INDOOR THE TERMS "APPROVED EQUAL", "EQUIVALENT", OR "EQUAL" ARE USED SYNONYMOUSLY HEATERS IN EACH PHASE. AMBIENT COMPENSATED HEATERS SHALL BE INSTALLED INSTALLATIONS. IF THE BASE PLATES ARE BOLTED TO THE STRUCTURE, INSTALL A AND SHALL MEAN "ACCEPTED BY OR ACCEPTABLE TO THE ENGINEER AS EQUIVALENT TO DURING THE COURSE OF CONSTRUCTION, COLLECT AND COMPILE A COMPLETE BROCHURE WHEREVER NECESSARY. UNLESS NOTED OTHERWISE, MOTOR STARTERS SHALL BE NEOPRENE VIBRATION ISOLATION WASHER AND SLEEVE (UNIROYAL TYPE 620/660 Ep PROFS,, THE ITEM OR MANUFACTURER SPECIFIED". THE TERM "APPROVED" SHALL MEAN LABELED, OF EQUIPMENT FURNISHED AND INSTALLED ON THIS PROJECT. INCLUDE OPERATIONAL FURNISHED BY THE DIVISION 15 CONTRACTOR FOR INSTALLATION AND CONNECTION BY OR AS APPROVED) UNDER THE BOLT HEAD BETWEEN THE STEEL WASHER AND �`c�� GINS `s, LISTED, OR BOTH, BY A NATIONALLY RECOGNIZED TESTING LABORATORY (E.G. UL, ETL, CSA), AND MAINTENANCE INSTRUCTIONS, MANUFACTURER'S CATALOG SHEETS, WIRING THE DIVISION 16 CONTRACTOR. STARTERS SHALL BE ALLEN—BRADLEY, CLARK, FURNAS, THE BASE PLATE. PROVIDE MASON INDUSTRIES TYPE SLFH OR EQUAL. �� �N ,,, AND ACCEPTABLE TO THE AHJ OVER THIS PROJECT. DIAGRAMS, PARTS LISTS, APPROVED SHOP DRAWINGS, AND DESCRIPTIVE LITERATURE AS SQUARE D, OR APPROVED EQUAL. CURB MOUNTED BASE): CURB MOUNTED BASE FOR ROOF—MOUNTED 84242PE D. TYPE CMB M FURNISHED BY THE EQUIPMENT MANUFACTURER. INCLUDE AN INSIDE COVER SHEET THAT EQUIPMENT (SHALL BEA STRUCTURAL STEEL BASE MOUNTED DIRECTLY M THE PREBID SITE VISIT LISTS THE PROJECT NAME, DATE, OWNER, ARCHITECT, CONSULTING ENGINEER, GENERAL ELECTRICAL WIRING STRUCTURE WITH AN UPPER FLOATING SECTION ON ADJUSTABLE STEEL SPRINGS. CONTRACTOR, SUB—CONTRACTOR, AND AN INDEX OF CONTENTS. PRIOR TO SUBMITTING BID, VISIT THE SITE OF THE PROPOSED WORK AND BECOME FULLY LINE VOLTAGE WIRING SHALL BE PROVIDED BY DIVISION 16. LINE VOLTAGE CONTROL AND THE UPPER FRAME SHALL PROVIDE CONTINUOUS SUPPORT FOR THE EQUIPMENT. E N INFORMED AS TO THE CONDITIONS UNDER WHICH THE WORK IS TO BE DONE. FAILURE TO SUBMIT THREE COPIES OF LITERATURE BOUND IN APPROVED BINDERS WITH INDEX AND INTERLOCK WIRING FOR MECHANICAL SYSTEMS SHALL ALSO BE PROVIDED BY DIVISION 16 STEEL SPRINGS SHALL REST ON 1/4" MIN. THICKNESS NEOPRENE PADS AND SHALL ,0vG C • Q7 DO SO WILL NOT BE CONSIDERED SUFFICIENT JUSTIFICATION TO REQUEST OR OBTAIN TABS SEPARATING EQUIPMENT TYPES TO THE ARCHITECT AT THE TERMINATION OF THE CONTRACTOR. LOW VOLTAGE CONTROL WIRING SHALL BE PROVIDED BY THE DIVISION 15 HAVE A MINIMUM STATIC DEFLECTION OF 2 UNLESS OTHERWISE SPECIFIED. 'Sj 2 � EXTRA COMPENSATION OVER AND ABOVE THE CONTRACT PRICE. WORK. PAPER CLIPS, STAPLES, RUBBER BANDS, AND MAILING ENVELOPES ARE NOT CONTRACTOR. FURNISH WIRING DIAGRAMS TO THE DIVISION 16 CONTRACTOR AS ALL—DIRECTIONAL SNUBBER BUSHINGS SHALL BE 1/4" MINIMUM THICKNESS / \� CONSIDERED APPROVED BINDERS. FINAL APPROVAL OF MECHANICAL SYSTEMS INSTALLED REQUIRED FOR PROPER EQUIPMENT HOOKUP. COORDINATE WITH THE DIVISION 16 NEOPRENE. ALL HARDWARE SHALL BE CADMIUM OR ZINC ELECTROPLATED TO MATERIAL AND WORKMANSHIP UNDER THIS CONTRACT WILL BE WITHHELD UNTIL THIS EQUIPMENT BROCHURE IS CONTRACTOR THE ACTUAL WIRE SIZING AMPS FOR MECHANICAL EQUIPMENT (FROM THE PROVIDE A RUST RESISTANT FINISH. WEATHER PROOFING SHALL CONSIST OF A r RECEIVED AND DEEMED COMPLETE BY THE ARCHITECT AND ENGINEER. INSTRUCT EQUIPMENT NAMEPLATE) TO ENSURE PROPER INSTALLATION. CONTINUOUS GALVANIZED FLEXIBLE COUNTERFLASHING NAILED OVER THE Consultant PROVIDE NEW MATERIAL, EQUIPMENT, AND APPARATUS UNDER THIS CONTRACT UNLESS WORKMEN TO SAVE REQUIRED LITERATURE SHIPPED WITH THE EQUIPMENT ITSELF, FOR LOWER CURB'S WATERPROOFING AND JOINED AT THE CORNERS BY EPDM OTHERWISE STATED HEREIN, OF BEST QUALITY NORMALLY USED FOR THE PURPOSE IN INCLUSION IN THIS BROCHURE. REFRIGERANT AND OIL BELLOWS. ALL SPRING LOCATIONS SHALL HAVE ACCESS PORTS WITH GOOD COMMERCIAL PRACTICE, AND FREE FROM DEFECTS. MODEL NUMBERS LISTED IN THE REMOVABLE WATERPROOF COVERS TO ALLOW FOR ADJUSTMENT OR SPECIFICATIONS OR SHOWN ON THE DRAWINGS ARE NOT NECESSARILY INTENDED TO PROVIDE "AS—BUILT" DRAWINGS (SEE DIVISION 1 AND GENERAL CONDITIONS). PROVIDE FULL REFRIGERANT AND OIL CHARGE IN NEW AIR CONDITIONING REFRIGERATION REPLACEMENT OF SPRINGS. LOWER CURBS SHALL HAVE PROVISION FOR 2" HENDERSON DESIGNATE THE REQUIRED TRIM, WRITTEN DESCRIPTIONS OF THE TRIM GOVERN MODEL SYSTEMS, AND MAINTAIN IT FOR FULL TERM OF THE GUARANTEE. INSULATION. DUCT CONNECTIONS SHALL BE MADE USING A LENGTH OF FLEXIBLE NUMBERS. TRAINING I DUCT DIMENSIONED TO MATCH THE EQUIPMENT OPENING, USING A FOAM RUBBER ENGINEERSM ALL NEW MECHANICAL EQUIPMENT SHALL UTILIZE R-410A. GASKET TO SEAL AGAINST THE UNIT BOTTOM. PROVIDE MASON INDUSTRIES TYPE r7xj PIPE, PIPE FITTINGS, PIPE SPECIALTIES, AND VALVES SHALL BE MANUFACTURED IN PLANTS AT A TIME MUTUALLY AGREED UPON BETWEEN THE OWNER AND CONTRACTOR, PROVIDE RSC, OR EQUAL. 8345 LENEXA DRIVE,SURE 300 LOCATED IN THE UNITED STATES. THE SERVICES OF A FACTORY TRAINED AND AUTHORIZED REPRESENTATIVE TO TRAIN FINAL TESTING AND ADJUSTMENTS LENEXA,KS 66214 OWNER'S DESIGNATED PERSONNEL ON THE OPERATION AND MAINTENANCE OF THE E. TYPE NR (NEOPRENE MOUNTS): PROVIDE NEOPRENE, RUBBER—IN—SHEAR MOUNTS TEL 913 742 5000 Fax 913 742 5001 WORK PERFORMED UNDER THIS CONTRACT SHALL PROVIDE A NEAT AND "WORKMANLIKE" EQUIPMENT PROVIDED FOR THIS PROJECT. FINAL SYSTEM TESTING, BALANCING, AND ADJUSTMENTS SHALL BE PERFORMED BY A FOR LIGHT WEIGHT, SUSPENDED EQUIPMENT SUPPORTED FROM STRUCTURE wwwheli-eng.com APPEARANCE WHEN COMPLETED, TO THE SATISFACTION OF THE ARCHITECT AND CONTRACTOR CERTIFIED BY THE NATIONAL ENVIRONMENTAL BALANCING BUREAU (NEBB), WITH ALL THREAD ROD AND ANGLE IRON OR UNISTRUT. PROVIDE MASON 1550003152 ENGINEER. WORKMANSHIP SHALL BE THE FINEST POSSIBLE BY EXPERIENCED MECHANICS. PROVIDE TRAINING TO INCLUDE BUT NOT BE LIMITED TO AN OVERVIEW OF THE SYSTEM ASSOCIATED AIR BALANCE COUNCIL (AABC), OR OTHER APPROVED AGENCY. PERFORM INDUSTRIES TYPE HMIB OR EQUAL. INSTALLATIONS SHALL COMPLY WITH APPLICABLE CODES AND LAWS. AND/OR EQUIPMENT AS IT RELATES TO THE FACILITY AS A WHOLE; OPERATION AND TEST READINGS ON FANS, UNITS, COILS, ETC. AND ADJUST EQUIPMENT TO DELIVER MAINTENANCE PROCEDURES AND SCHEDULES RELATED TO STARTUP AND SHUTDOWN, SPECIFIED AMOUNTS OF AIR. PREPARE TESTING AND BALANCING REPORT LOG SHOWING 15A SEISMIC CONTROLS FOR MEPF SYSTEMS JobNameandNurnW.. THE COMPLETE INSTALLATION SHALL FUNCTION AS DESIGNED AND INTENDED WITH TROUBLESHOOTING, SERVICING, PREVENTIVE MAINTENANCE, AND APPROPRIATE AIR SUPPLY QUANTITIES, AIR ENTERING AND LEAVING TEMPERATURES AND PRESSURES, SEISMIC PROTECTION CRITERIA: 2015-0131 RESPECT TO EFFICIENCY, CAPACITY, NOISE LEVEL, ETC. ABNORMAL NOISE CAUSED BY OPERATOR INTERVENTION; AND REVIEW OF DATA INCLUDED IN THE OPERATION AND FAN AND UNIT TEST READINGS, OUTSIDE AIR QUANTITIES, MOTOR VOLTAGE AND AMP RISK/OCCUPANCY CATEGORY: I, II or III RATTLING EQUIPMENT, PIPING, DUCTS, AIR DEVICES, AND SQUEAKS IN ROTATING MAINTENANCE MANUALS. DRAWS, ETC., AND SUBMIT SIX COPIES OF THE FINAL COMPILATION OF DATA TO THE SITE SOIL CATEGORY: CONTRACTOR'S SEISMIC ENGINEER TO Proposed COMPONENTS WILL NOT BE ACCEPTABLE. IN GENERAL, MATERIALS AND EQUIPMENT ARCHITECT FOR EVALUATION AND APPROVAL BEFORE FINAL INSPECTION OF THE PROJECT. DETERMINE SHALL BE OF COMMERCIAL SPECIFICATION GRADE IN QUALITY. LIGHT DUTY AND SUBMIT A CERTIFICATION LETTER TO THE ARCHITECT STATING THAT THE OWNER'S BALANCE EXHAUST AIR SYSTEMS TO WITHIN PLUS OR MINUS 10 PERCENT AND OUTSIDE AIR SEISMIC DESIGN CATEGORY: CONTRACTOR'S SEISMIC ENGINEER TO RESIDENTIAL TYPE EQUIPMENT WILL NOT BE ACCEPTED. DESIGNATED REPRESENTATIVE HAS BEEN TRAINED AS SPECIFIED HEREIN. LETTER SHALL TO WITHIN PLUS 5 PERCENT. BALANCE ALL OTHER SYSTEMS WITHIN PLUS OR MINUS 10 DETERMINE VERIZON INCLUDE DATE, TIME, ATTENDEES, AND SUBJECT OF TRAINING. THE CONTRACTOR AND THE PERCENT FOR TERMINAL DEVICES AND BRANCH LINES AND PLUS OR MINUS 5 PERCENT FOR COMPONENT IMPORTANCE FACTOR: DETERMINED FROM ASCE 7-2010 REMOVE FROM THE PREMISES WASTE MATERIAL PRESENT AS A RESULT OF WORK, OWNER'S REPRESENTATIVE SHALL SIGN THE CERTIFICATION LETTER INDICATING MAIN DUCTS AND AIR HANDLING EQUIPMENT OF THE AMOUNT OF AIR SHOWN ON THE STORE INCLUDING CARTONS, CRATING, PAPER, STICKERS, AND/OR EXCAVATION MATERIAL NOT AGREEMENT THAT THE TRAINING HAS BEEN PROVIDED. DRAWINGS. FURTHER ADJUSTMENTS SHALL BE MADE TO OBTAIN UNIFORM TEMPERATURE THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE USED IN BACKFILLING, ETC. CLEAN EQUIPMENT INSTALLED UNDER THIS CONTRACT TO IN SPACES. ADJUST EQUIPMENT TO OPERATE AS INTENDED BY THE SPECIFICATION. ALIGN REQUIREMENTS FOR SEISMIC BRACING OF MECHANICAL, ELECTRICAL, AND PRESENT A NEAT AND CLEAN INSTALLATION AT THE TERMINATION OF THE WORK. SCHEDULE OWNER TRAINING WITH AT LEAST 7 DAYS' ADVANCE NOTICE. BEARINGS AND REPLACE BEARINGS THAT HAVE DIRT OR FOREIGN MATERIAL IN THEM WITH PLUMBING SYSTEMS. SEISMIC PROTECTION CRITERIA USED TO DETERMINE (LEED) NEW BEARINGS WITHOUT ADDITIONAL COST TO THE OWNER. BALANCE CONTRACTOR SEISMIC BRACING REQUIREMENTS OF ALL MECHANICAL, ELECTRICAL AND REPAIR OR REPLACE PUBLIC AND PRIVATE PROPERTY DAMAGED AS A RESULT OF WORK SPARE PARTS SHALL INCLUDE IN THE REPORT ANY IMPROPERLY INSTALLED OR MISSING BALANCING PLUMBING SYSTEMS SHALL BE DETERMINED BY THE APPLICABLE CODE ADOPTED PERFORMED UNDER THIS CONTRACT TO THE SATISFACTION OF AUTHORITIES AND DEVICES THAT WOULD NEGATIVELY IMPACT THE SYSTEM OPERATION. IN THE PROJECT JURISDICTION. WHERE NOT ALREADY DETERMINED WITHIN THE REGULATIONS HAVING JURISDICTION. FURNISH TO OWNER, WITH RECEIPT, THE FOLLOWING SPARE PARTS FOR THE EQUIPMENT CONTRACT DOCUMENTS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR FURNISHED FOR THIS PROJECT: ADJUST THERMOSTATS AND CONTROL DEVICES TO OPERATE AS INTENDED. ADJUST CONTRACTING A LICENSED PROFESSIONAL ENGINEER TO ESTABLISH BUILDING COORDINATION BURNERS, FANS, ETC. FOR PROPER AND EFFICIENT OPERATION. CERTIFY TO ARCHITECT SITE CLASS, SEISMIC DESIGN CATEGORY, SEISMIC ZONE OR ANY OTHER CRITERIA A. ONE SET OF SPARE FILTERS OF EACH TYPE REQUIRED FOR EACH UNIT. IN ADDITION TO THE THAT ADJUSTMENTS HAVE BEEN MADE AND THAT SYSTEM IS OPERATING SATISFACTORILY. NECESSARY TO DETERMINE THE REQUIREMENTS FOR SEISMIC BRACING ON SPARE SET OF FILTERS, INSTALL NEW FILTERS PRIOR TO TESTING, ADJUSTING, AND kbAdaess COORDINATE WORK WITH THAT OF OTHER TRADES SO THAT THE VARIOUS COMPONENTS FURTHER ADJUSTMENTS SHALL BE MADE TO OBTAIN UNIFORM TEMPERATURE IN SPACES. MECHANICAL, ELECTRICAL AND/OR PLUMBING SYSTEMS. OF THE SYSTEMS WILL BE INSTALLED AT THE PROPER TIME, WILL FIT THE AVAILABLE SPACE, BALANCING WORK AND BEFORE TURNING SYSTEM OVER TO OWNER. CALIBRATE, SET, AND ADJUST AUTOMATIC TEMPERATURE CONTROLS. CHECK PROPER Washington Square Mall AND WILL ALLOW PROPER SERVICE WHICH ARE INSTALLED TREGARD CESS OTHOSE ITEMS T MHE ABOVE SHALL MAINTENANCE. g FURNISH ONE COMPLETE SET OF BELTS FOR EACH FAN. SEQUENCING OF INTERLOCK SYSTEMS, AND OPERATION OF SAFETY CONTROLS. SEISMIC BRACING OF FIRE PROTECTION SYSTEMS SHALL BE INSTALLED IN STRICT 9585 S.W. Washington ACCORDANCE WITH THE PROVISIONS OF NFPA 13 (2010 OR LATER EDITION). RELOCATED AT NO ADDITIONAL COST TO THE OWNER. C. FURNISH THREE OPERATING KEYS FOR EACH TYPE OF AIR OUTLET AND INLET THAT REQUIRE MERV-13 FILTERS SHALL BE INSTALLED PRIOR TO TEST AND BALANCE. Square Road c� THEM. THE CONTRACTOR SHALL DETERMINE THE TYPE AND LOCATION OF SEISMIC Portland 0R 97223 9 UNLESS OTHERWISE INDICATED, THE GENERAL CONTRACTOR WILL PROVIDE CHASES AND CONTRACTOR SHALL COMPLY WITH THE REQUIREMENTS LISTED UNDER COMMISSIONING BRACING REQUIRED FOR THE MECHANICAL ELECTRICAL AND PLUMBING f q OPENINGS IN BUILDING CONSTRUCTION REQUIRED FOR INSTALLATION OF THE SYSTEMS ON THE LEED PROTOTYPE GREEN SPECIFICATIONS. r7 SPECIFIED HEREIN. CONTRACTOR SHALL FURNISH THE GENERAL CONTRACTOR WITH WARRANTIES ELEMENTS SHOWN ON THE DRAWINGS BASED ON THE ESTABLISHED SEISMIC pace R 5-R 7 N CRITERIA, THE SIZE AND WEIGHT OF THE SUPPORTED ELEMENT AND THE � INFORMATION WHERE CHASES AND OPENINGS ARE REQUIRED. KEEP INFORMED AS TO THE EQUIPMENT FURNISHED BY OTHERS DISTANCE FROM STRUCTURE OF THE SUPPORTED ELEMENT. WORK OF OTHER TRADES ENGAGED IN THE CONSTRUCTION OF THE PROJECT, AND EXECUTE WARRANT EACH SYSTEM AND EACH ELEMENT THEREOF AGAINST ALL DEFECTS DUE TO W) WORK IN A MANNER AS TO NOT INTERFERE WITH OR DELAY THE WORK OF OTHER TRADES. FAULTY WORKMANSHIP, DESIGN, OR MATERIAL FOR A PERIOD OF 12 MONTHS FROM DATE PROVIDE NECESSARY EQUIPMENT AND ACCESSORIES THAT ARE NOT PROVIDED BY THE orawrn� 0 OF SUBSTANTIAL COMPLETION, UNLESS SPECIFIC ITEMS ARE NOTED TO CARRY A LONGER THE CONTRACTOR SHALL SUBMIT THE FOLLOWING SHOP DRAWING INFORMATION MECHANICAL >71 0WARRANTY IN THE CONSTRUCTION DOCUMENTS OR MANUFACTURER'S STANDARD EQUIPMENT SUPPLIER OR OWNER TO COMPLETE INSTALLATION OF EQUIPMENT TO THE AUTHORITY HAVING JURISDICTION AND THE ENGINEER OF RECORD FOR : rn FIGURED DIMENSIONS SHALL BE TAKEN IN PREFERENCE TO SCALE DIMENSIONS. FURNISHED BY OTHERS, IN LOCATIONS AS INDICATED ON THE DRAWINGS AND/OR REVIEW AND APPROVAL: (1) SEISMIC ANALYSIS LISTING ALL APPLICABLE SEISMIC 2 j CONTRACTOR SHALL TAKE HIS OWN MEASUREMENTS AT THE BUILDING, AS VARIATIONS WARRANTY EXCEEDS 12 MONTHS. REMEDY ALL DEFECTS, OCCURRING WITHIN THE DESCRIBED IN THE GENERAL NOTES TO THIS CONTRACTOR. EQUIPMENT AND ACCESSORIES SPECIFICATIONS 0 MAY OCCUR. CONTRACTOR WILL BE HELD RESPONSIBLE FOR ERRORS THAT COULD HAVE WARRANTY PERIOD(S), AS STATED IN THE GENERAL CONDITIONS AND DIVISION 1. NOT PROVIDED BY THE EQUIPMENT SUPPLIER MAY INCLUDE CONDENSATE DRAINS, FLUES, DESIGN CRITERIA (2) DESCRIPTIVE CATALOG DATA OF SEISMIC BRACING v MATERIALS, (3) SHOP DRAWINGS SHOWING BRACING TYPE AND LOCATION, (4) a Uj BEEN AVOIDED BY PROPER CHECKING AND INSPECTION. VENTS, INTAKES, ASSOCIATED ROOF JACKS AND CAPS TO OUTDOORS, DAMPERS, IN—LINE INSTALLATION DETAILS OF ALL BRACING USED AND 5 CALCULATIONS SHOWING WARRANTIES SHALL INCLUDE LABOR AND MATERIAL. MAKE REPAIRS OR REPLACEMENTS ( ) o WITHOUT ANY ADDITIONAL COSTS TO THE OWNER. FANS, ROOF FANS, CONTROL INTERLOCKS, ETC. AS REQUIRED FOR PROPER OPERATION OF THAT THE SEISMIC RESTRAINTS MEET THE SEISMIC REQUIREMENTS. SHOP 0 0o PROVIDE MATERIALS WITH TRIM THAT WILL PROPERLY FIT THE TYPES OF CEILING, WALL, OR THE COMPLETE SYSTEM IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. DRAWINGS AND CALCULATIONS SHALL BE SIGNED AND SEALED BY A REGISTERED FLOOR FINISHES ACTUALLY INSTALLED. MODEL NUMBERS LISTED IN THE SPECIFICATIONS N OR SHOWN ON THE DRAWINGS ARE NOT INTENDED TO DESIGNATE THE REQUIRED TRIM. PERFORM THE REMEDIAL WORK PROMPTLY, UPON WRITTEN NOTICE FROM THE ENGINEER CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECT ROUGH—IN DIMENSIONS, AND SHALL PROFESSIONAL ENGINEER, LICENSED IN THE STATE OF THE PROJECT AND o OR OWNER. EMPLOYED BY THE MANUFACTURER OF THE SEISMIC BRACING PRODUCTS. ;, VERIFY SAME WITH ARCHITECT AND/OR EQUIPMENT SUPPLIER PRIOR TO SERVICE CALCULATIONS SHALL INCLUDE DEAD LOADS, STATIC SEISMIC LOADS AND Drawn By: North N o ORDINANCES AND CODES AT THE TIME OF SUBSTANTIAL COMPLETION, DELIVER TO THE OWNER ALL WARRANTIES, IN INSTALLATIONS. CAPACITY OF MATERIALS UTILIZED FOR CONNECTIONS. " co ¢ WRITING AND PROPERLY EXECUTED, INCLUDING TERM LIMITS FOR WARRANTIES Checked By. o WORK PERFORMED UNDER THIS CONTRACT SHALL, AT A MINIMUM, BE IN CONFORMANCE MISCELLANEOUS REMODELING WORK SEISMIC BRACING, RESTRAINTS, ISOLATORS, AND ISOLATION MATERIALS SHALL BE 0 � WITH APPLICABLE NATIONAL, STATE, AND LOCAL CODES HAVING JURISDICTION. EXTENDING BEYOND THE ONE YEAR PERIOD, EACH WARRANTY INSTRUMENT BEING ADDRESSED TO THE OWNER AND STATING THE COMMENCEMENT DATE AND TERM. OF THE SAME MANUFACTURER AND SHALL BE CERTIFIED BY THE MANUFACTURER. Date Issued For a. I EQUIPMENT FURNISHED AND ASSOCIATED INSTALLATION WORK PERFORMED UNDER THIS REMOVE ALL UNUSED EQUIPMENT, DUCTWORK, PIPING, AND ASSOCIATED SUPPORTS. CAP APPROVED MANUFACTURERS ARE: AMBER/BOOTH COMPANY, INC., KINETICS Client i2124/2015 3 w CONTRACT SHALL BE IN STRICT COMPLIANCE WITH CURRENT APPLICABLE CODES ADOPTED DUCTWORK AND PIPING AT MAINS AND SEAL AIR AND WATER TIGHT. NOISE CONTROL, INC., LOOS & COMPANY, INC., MASON INDUSTRIES, INC., UNI— CUTTING AND PATCHING Landlard2f24/2015 M a BY THE LOCAL AHJ INCLUDING ANY AMENDMENTS AND STANDARDS AS SET FORTH BY THE STRUT, VIBRO—ACOUSTICS, OR B—LINE/TOLCO. EACH DEVICE SHALL HAVE A PRE- 2 � NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), UNDERWRITERS LABORATORIES (UL), PROVIDE ITEMS OF HVAC SYSTEMS MODIFICATION REQUIRED BECAUSE OF BUILDING APPROVAL NUMBER FROM CALIFORNIA OSHPD OR OTHER RECOGNIZED Pernnitl1-2/24/2015 PERFORM CUTTING OF WALLS, FLOORS, CEILINGS, ETC. AS REQUIRED TO INSTALL WORK co OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA), AMERICAN SOCIETY OF UNDER THIS SECTION. OBTAIN PERMISSION FROM THE ARCHITECT PRIOR TO CUTTING. DO REMODELING, AS NOTED ON THE DRAWINGS OR NECESSARY FOR PROPER OPERATION. GOVERNMENT AGENCY SHOWING MAXIMUM RESTRAINT RATINGS. Bid: C, z MECHANICAL ENGINEERS (ASME), AMERICAN SOCIETY OF HEATING, REFRIGERATION AND MATCH EXISTING MATERIALS AND CONSTRUCTION TECHNIQUES WHEN MODIFYING 0 o ' NOT CUT OR DISTURB STRUCTURAL MEMBERS WITHOUT PRIOR APPROVAL FROM THE Construction: In � AIR CONDITIONING ENGINEERS (ASHRAE), AMERICAN NATIONAL STANDARDS INSTITUTE EXISTING SYSTEMS UNLESS SPECIFIED OTHERWISE. COORDINATE ADDITIONAL SEISMIC BRACING MEASURES TO BE APPLIED TO e3 ARCHITECT. CUT HOLES AS SMALL AS POSSIBLE. GENERAL CONTRACTOR SHALL PATCH Revision issue: z (ANSI), AMERICAN SOCIETY OF TESTING MATERIALS (ASTM), AND OTHER NATIONAL WALLS, FLOORS, ETC. AS REQUIRED BY WORK UNDER THIS SECTION. PATCHING SHALL REQUIREMENTS WITH GENERAL CONTRACTOR AND ARCHITECT. MECHANICAL/ELECTRICAL/PLUMBING EQUIPMENT AND SYSTEMS SHALL BE a) = STANDARDS AND CODES WHERE APPLICABLE. WHERE THE CONTRACT DOCUMENTS EXCEED INSTALLED IN STRICT ACCORDANCE WITH ALL APPLICABLE LOCAL, STATE, AND/OR No. Data aesviptian THE REQUIREMENTS OF THE REFERENCED CODES, STANDARDS, ETC., THE CONTRACT MATCH THE ORIGINAL MATERIAL AND CONSTRUCTION. REPAIR AND REFINISH AREAS CAP AND SEAL WEATHERTIGHT EXISTING ROOF CURBS AND ROOF OPENINGS TO BE / 0 3 DISTURBED BY WORK TO THE CONDITION OF ADJOINING SURFACES IN A MANNER FEDERAL CODES AS WELL AS MANUFACTURER'S REQUIREMENTS. THE MOST o I DOCUMENTS SHALL TAKE PRECEDENCE. SATISFACTORY TO THE ARCHITECT. ABANDONED IN PLACE AS A RESULT OF EQUIPMENT REMOVAL. STRINGENT CRITERIA SHALL APPLY. ALL ANCHOR CONNECTIONS TO STRUCTURE i 0 PERMITS AND LICENSES REQUIRED FOR THE ACCOMPLISHMENT OF VIBRATION ISOLATION FOR SUPPORT OF MECHANICAL AND ELECTRICAL EQUIPMENT, REGARDLESS OF THE WORK HEREIN DESCRIBED. WHERE REQUIRED, OBTAIN, PAY FOR, AND FURNISH ROUGH—IN THE NEED FOR SEISMIC RESTRAINTS, SHALL BE SHOWN ON SHOP DRAWINGS. � CERTIFICATES OF INSPECTION TO OWNER. CONTRACTOR WILL BE HELD RESPONSIBLE FOR COORDINATE WITHOUT DELAY ROUGHING—IN WITH GENERAL CONSTRUCTION. CONCEAL MANUFACTURERS: PROVIDE VIBRATION ISOLATION EQUIPMENT AND MATERIALS 15A 2 DUCT INSULATION, DUCTWORK, ACCESSORIES, AND FANS cc VIOLATIONS OF THE LAW. BY A SINGLE MANUFACTURER. IF TYPE AND DEFLECTION FOR SPECIFIC Cr M PIPING AND CONDUIT ROUGH—IN EXCEPT IN UNFINISHED AREAS AND WHERE OTHERWISE o EQUIPMENT IS NOT SPECIFIED WITHIN THE CONTRACT DOCUMENTS, REFERENCE DUCT INSULATION o PROTECTION OF EQUIPMENT AND MATERIALS SHOWN. ASHRAE HANDBOOK "HVAC APPLICATIONS" OR PROVIDE PER MANUFACTURER'S RECOMMENDATIONS. APPROVED MANUFACTURERS PROVIDED THEIR SYSTEMS COVER CONCEALED RIGID ROUND AND RECTANGULAR DUCTWORK WITH 2-1 4" THICK, 3 4 r STRUCTURAL STEEL / / N j STORE AND PROTECT FROM DAMAGE EQUIPMENT AND MATERIALS DELIVERED TO JOB SITE. ARE IN COMPLIANCE WITH THE SPECIFIED DESIGN AND PERFORMANCE POUND DENSITY, MINIMUM R-6.0 DUCT WRAP, CERTAINTEED, OR EQUIVALENT OWENS— Zo COVER WITH WATERPROOF, TEAR—RESISTANT HEAVY TARP OR POLYETHYLENE PLASTIC AS STRUCTURAL STEEL USED FOR SUPPORT OF EQUIPMENT, DUCTWORK, AND PIPING SHALL BE REQUIREMENTS INCLUDE AMBER BOOTH, KINETICS NOISE CONTROL, MASON CORNING OR KNAUF WITH HEAVY—DUTY FOIL—SCRIM—KRAFT FACING, AND WITH JOINTS � N REQUIRED TO PROTECT FROM PLASTER, DIRT, PAINT, WATER, OR PHYSICAL DAMAGE. NEWCLEANAND CONFORM TO ASTM DESIGNATION A-36INDUSTRIES, INC., VIBRATION ELIMINATOR CO., INC., AND VIBRATION MOUNTING TAPED WITH 3" WIDE FOIL TAPE AS FOLLOWS: N , , .Ix EQUIPMENT AND MATERIAL THAT HAS BEEN DAMAGED BY CONSTRUCTION ACTIVITIES AND CONTROLS. > !� WILLBE REJECTED, AND CONTRACTOR IS OBLIGATED TO FURNISH NEW EQUIPMENT AND A. SUPPLY AND RETURN AIR DUCTWORK IN ENTIRETY SUPPORT MECHANICAL COMPONENTS FROM THE BUILDING STRUCTURE. DO NOT MN MATERIAL OF A LIKE KIND. GENERAL REQUIREMENTS: SELECT VIBRATION ISOLATORS BY THE WEIGHT 0 1 SUPPORT MECHANICAL COMPONENTS FROM CEILINGS, OTHER MECHANICAL OR DISTRIBUTION TO PRODUCE UNIFORM DEFLECTION. VIBRATION ISOLATORS SHALL N j ELECTRICAL COMPONENTS, AND OTHER NON—STRUCTURAL ELEMENTS. B. EXHAUST AND RELIEF AIR DUCTWORK WITHIN 10 FEET OF EXTERIOR DISCHARGE KEEP PREMISES BROOM CLEAN FROM FOREIGN MATERIAL CREATED DURING WORK HAVE EITHER KNOWN UN—DEFLECTED HEIGHTS OR CALIBRATION MARKINGS SO X PERFORMED UNDER THIS CONTRACT. PIPING, EQUIPMENT, ETC. SHALL HAVE A NEAT AND THAT, AFTER ADJUSTMENT, THE STATIC DEFLECTION CAN BE VERIFIED, THUS INSULATING MATERIALS, ADHESIVES, COATINGS, ETC., SHALL NOT EXCEED FLAME SPREAD ACCESS DOORS DravdngNumbw: 0 CLEAN APPEARANCE AT THE TERMINATION OF THE WORK. DETERMINING THAT THE LOAD IS WITHIN THE PROPER RANGE OF THE ISOLATOR. RATING OF 25 AND SMOKE DEVELOPED RATING OF 50 PER ASTM E 84. CONTAINERS FOR o ISOLATORS SHALL OPERATE IN THE LINEAR PORTION OF THEIR LOAD VERSUS MASTICS AND ADHESIVES SHALL HAVE U.L. LABEL. r4 M x PROVIDE ACCESS DOORS IN CEILINGS, WALLS, ETC. WHERE INDICATED OR REQUIRED FOR o_ PLUG OR CAP OPEN ENDS OF DUCTWORK AND PIPING SYSTEMS WHILE STORED AND DEFLECTION CURVES. SPRING ISOLATORS SHALL HAVE 50 PERCENT EXCESS ACCESS OR MAINTENANCE TO CONCEALED VALVES AND EQUIPMENT INSTALLED UNDER c� � INSTALLED DURING CONSTRUCTION WHEN NOT IN USE TO PREVENT THE ENTRANCE OF CAPACITY WITHOUT BECOMING COIL BOUND. COAT VIBRATION ISOLATORS WITH 2 � DEBRIS INTO THE SYSTEMS. THIS SECTION. PROVIDE CONCEALED HINGES, SCREWDRIVER—TYPE LOCK, ANCHOR STRAPS; FACTORY—APPLIED PAINT. COAT VIBRATION ISOLATORS EXPOSED TO WEATHER o J Z MANUFACTURED BY MILCOR, ZURN, TITUS, OR EQUAL. OBTAIN ARCHITECT'S APPROVAL OF AND OTHER CORROSIVE ENVIRONMENTS WITH FACTORY—APPLIED CORROSION I j M3 LEED NOTES PROVIDED IN BOXES FOR CLARITY TYPE, SIZE, LOCATION AND COLOR BEFORE ORDERING. RESISTANCE PROTECTION. INSTALL AND ADJUST VIBRATION ISOLATORS IN d a � ACCORDANCE WITH MANUFACTURERS WRITTEN INSTRUCTIONS. 20 OF 31 DUCTWORK 15A HYDRONIC SPECIALTIES 15A FAN COIL UNITS CHILLED WATER EXHAUST FAN CONTROL DUCT CONSTRUCTION, BOTH METAL AND FLEXIBLE, SHALL BE PERFORMED IN ACCORDANCE PROVIDE SHUTOFF VALVES 2" AND SMALLER WITH THREADED ENDS AND BRONZE BODY PROVIDE CHILLED WATER FAN COIL UNITS AS SCHEDULED ON THE DRAWINGS, EF-1 AND EF-2: EXHAUST FAN SHALL BE INTERLOCKED WITH RESPECTIVE RESTROOM LIGHT WITH CURRENT SMACNA HVAC DUCT CONSTRUCTION STANDARDS. CONSTRUCTION. PROVIDE VALVES LARGER THAN 2" WITH FLANGED ENDS AND CAST IRON MANUFACTURED BY TRANE, CARRIER, DAIKIN, OR JOHNSON CONTROLS, HORIZONTAL SWITCHES/OCCUPANCY SENSORS AND BE ENERGIZED THRU A RELAY CONTROL WHEN LIGHT BODY CONSTRUCTION. PROVIDE RISING OR OS&Y STEMS EXTENDED TYPE IF INSULATED, CONFIGURATION COMPLETE WITH ZINC COATED, HEAVY GAUGE, GALVANIZED STEEL SWITCH IS 'ON' AND DE—ENERGIZED WHEN LIGHT SWITCH IS 'OFF'. CONTRACTOR SHALL DEVELOP AND IMPLEMENT AN INDOOR AIR QUALITY MANAGEMENT HANDWHEEL OPERATORS, SOLID DISCS, AND REPLACEABLE TEFLON PACKING. PROVIDE CABINET WITH WEATHER—RESISTANT BAKED ENAMEL FINISH; INTERNALLY INSULATED; PLAN THAT MEETS OR EXCEEDS THE MINIMUM REQUIREMENTS OF SMACNA IAQ LUG TYPE BUTTERFLY VALVES. VALVES SHALL BE CLASS 125 FOR GATE, CHECK AND GLOBE ACCESS DOORS; CHILLED WATER COOLING COIL SECTION OF ALUMINUM/COPPER EF-3: EXHAUST FAN SHALL BE INTERLOCKED WITH THERMOSTAT TO MAINTAIN ROOM GUIDELINES FOR OCCUPIED BUILDINGS UNDER CONSTRUCTION, SECOND EDITION 2007, VALVES, CLASS 150 FOR BALL VALVES, AND CLASS 200 FOR BUTTERFLY VALVES. VALVES CONSTRUCTION; CONDENSATE DRAIN PAN; STATICALLY AND DYNAMICALLY BALANCED TEMPERATURE SETPOINT (80 DEGREES FAHRENHEIT. (ADJUSTABLE). ANSI/SMACNA 008-2008 CHAPTER 3. CONTRACTOR SHALL MEET REQUIREMENTS FOR SHALL MEET MSS SPECIFICATIONS. INSTALL VALVES WHERE SHOWN AND WHERE CENTRIFUGAL FAN SECTION WITH BUILT—IN MOTOR THERMAL OVERLOAD PROTECTION; CONSTRUCTION INDOOR AIR QUALITY MANAGEMENT PROVIDED ON THE LEED PROTOTYPE NECESSARY FOR CUT—OFF, FOR BALANCING AND FOR CONTROL. VALVES SHALL BE CRANE, FACTORY INSTALLED AND WIRED CONTROLS AND SINGLE POINT ELECTRICAL POWER COMPUTER ROOM UNIT CONTROL GRUSKIN GREEN SPECIFICATION. HAMMOND, JENKINS, MILWAUKEE, NIBCO, POWELL, OR STOCKHAM. FOR 2" AND CONNECTION; MAGNETIC MOTOR STARTERS AND CONTACTORS AS REQUIRED; AIR FILTER SMALLER, REFERENCE MANUFACTURER WITH MODEL NUMBER FOR BALL VALVES IS NIBCO RACK WITH 1" THICK THROWAWAY FILTERS; FACTORY INSTALLED ELECTRIC HEATING COIL OPERATE COMPUTER ROOM UNIT CONTINUOUSLY. CYCLE STAGE(S) OF COOLING TO PROVIDE GALVANIZED STEEL DUCTWORK AND HOUSINGS AS SHOWN ON DRAWINGS. #T580, GATE VALVES IS NIBCO T-111, CHECK VALVES IS NIBCO T-413, AND GLOBE VALVES IS WITH CODE REQUIRED INTEGRAL SAFETY FEATURES AND CONTROLS. PROVIDE HONEYWELL MAINTAIN ROOM TEMPERATURE SETPOINT (70 DEGREES FAHRENHEIT, ADJUSTABLE). CONSTRUCT DUCTWORK INCLUDING FITTINGS AND TRANSITIONS IN CONFORMANCE WITH NIBCO T-21 1—B. FOR LARGER THAN 2", REFERENCE MANUFACTURER WITH MODEL NUMBER OR EQUAL ELECTRONIC PROGRAMMABLE TYPE THERMOSTAT, SEVEN—DAY MODEL, MANUAL LEED VERBIAGE TO BE BOXED ON SHEET M3. Tel Morris Avenue Springfield.NJ .8981 CURRENT SMACNA STANDARDS RELATIVE TO GAUGE, BRACING, JOINTS, ETC. MINIMUM FOR GATE VALVES IS NIBCO F-617-0, FOR CHECK VALVES IS NIBCO F-918, FOR GLOBE LEED VERBIAGE TO BE BOXED ON SHEET M3. www.GruskinGrou41 p.com omFaxNJRG0100.8989 CHANGEOVER, SWITCHING SUBBASE, MODULATING CHILLED WATER VALVE CONTROL AND www.GruskinGroup.com NJ REG 0100.9869-14 THICKNESS OF DUCT SHALL BE 26—GAUGE SHEET METAL. REINFORCE HOUSINGS AND VALVES IS NIBCO F-718—B, AND FOR BUTTERFLY VALVES IS NIBCO LD-20103. MULTI—STAGE ELECTRIC HEATING AS REQUIRED TO MATCH UNIT COOLING/HEATING LEED VERBIAGE TO BE BOXED ON SHEET M3. DUCTWORK OVER 30" WITH 1-1/4" ANGLES NOT LESS THAN 5'-6" ON CENTERS, AND CONFIGURATION. DIVISION 21 CONTRACTOR SHALL PROVIDE AND WIRE UL LISTED DUCT LEED VERBIAGE TO BE BOXED ON SHEET M3. This document and the ideas and designs incorporated CLOSER IF REQUIRED FOR SUFFICIENT RIGIDITY TO PREVENT VIBRATION. SUPPORT SIZE THE CONTROL VALVES TO PRODUCE THE REQUIRED CAPACITY AT A PRESSURE LOSS TYPE SMOKE DETECTORS AS REQUIRED BY CODE TO SHUT DOWN FAN COIL UNIT UPON LEED VERBIAGE TO BE BOXED ON SHEET M3. herein,as an Instrument of professional service, Is the HORIZONTAL RUNS OF DUCT FROM STRAP IRON HANGERS ON CENTERS NOT TO EXCEED 8'— NOT EXCEEDING 5 PSI. NOMINAL BODY RATING SHALL BE NOT LESS THAN 125 PSI. DETECTION OF SMOKE. PROVIDE SPRING VIBRATION ISOLATORS AND ALL—THREAD DELETE PARAGRAPHS IF ALL AIR DEVICES, DUCTWORK, AND HVAC EQUIPMENT ARE propertyof GRUSKIN ARCH ITECTURE+DESIGN,P.C.,and 0". DO NOT SUPPORT CEILING GRID, CONDUITS, PIPES, EQUIPMENT, ETC. FROM HOWEVER, SIZE VALVE BODY AND SELECT PACKING TO WITHSTAND THE SYSTEM STATIC HANGING RODS FOR HORIZONTAL INSTALLATIONS. PROVIDE AN AUXILIARY DRAIN PAN FOR SPECIFIED AS NEW. isnottobeusedinwholeorinpanforany other project DUCTWORK. COORDINATE ROUTING OF DUCTWORK WITH OTHER CONTRACTORS SUCH HEAD PLUS THE MAXIMUM PUMP HEAD AND THE MAXIMUM TEMPERATURE OF THE SUSPENDED UNITS WITH [AUXILIARY CONDENSATE DRAIN PROVIDED BY PLUMBING without the written authorIzatlonof GRUSKIN THAT PIPING, ELECTRICAL CONDUIT, AND ASSOCIATED SUPPORTS ARE NOT ROUTED CONTROL MEDIUM I.E. CHILLED WATER, HEATING WATER, ETC. . PROVIDE TWO—WAY ARCHITECTURE+DESIGN,P.C. ( ) CONTRACTOR. FLOAT SWITCH TO SHUT OFF UNIT WHEN WATER IS DETECTED IN AUXILIARY All RightsReserved THROUGH THE DUCTWORK. MODULATING VALVES WITH CLOSE—OFF RATINGS EXCEEDING THE MAXIMUM PRESSURE DRAIN PAN. FLOAT SWITCH SHALL BE AQUAHUB #FLT231 OR EQUAL BY COLE—PALMER, DIFFERENCE, AT ANY LOAD CONDITION, BETWEEN THE OUTLET AND INLET. EQUIP EACH FLOWLINE, OMEGA OR SMD MICRO FLOAT SWITCH WITH POLYPROPYLENE BODY AND ©2015GruskinArchitecture+Design,P.C. CONSTRUCT SUPPLY DUCTS TO MEET SMACNA POSITIVE PRESSURE OF 2" W.G. CONSTRUCT VALVE WITH PROPER PACKING TO ENSURE THERE WILL BE NO LEAKAGE AT THE VALVE FLOAT WITH 1/2" NPT PIPE CONNECTION AND NORMALLY CLOSED CONTACT. CONTACT KiFfl GNU" AIA RETURN, OUTDOOR AND EXHAUST DUCTWORK UPSTREAM OF FANS TO MEET SMACNA STEM. SHALL CLOSE WHEN FLOAT RAISES DUE TO WATER PRESENT IN DRAIN PAN MINIMUM 1" NEGATIVE PRESSURE OF 1" W.G. CONSTRUCT EXHAUST DUCTWORK DOWNSTREAM OF ABOVE BOTTOM OF PAN. INSTALL IN 1/2" COUPLING WELDED TO DRAIN PAN WITH AL 5421 MT 2537 FANS TO MEET SMACNA POSITIVE PRESSURE OF 1" W.G. PROVIDE VALVE OPERATORS FOR EACH AUTOMATIC VALVE WITH SUFFICIENT CAPACITY TO CENTERLINE 1" ABOVE BOTTOM OF PAN. AK 13167 INC 9961 OPERATE THE VALVE UNDER ALL CONDITIONS AND TO GUARANTEE TIGHT CLOSE—OFF OF AR 3811 ND 1666 SEAL DUCTWORK WITH HEAVY LIQUID SEALANT, HARDCAST IRONGRIP 601, DESIGN DAMPERS OR VALVES AS SPECIFIED AGAINST SYSTEM PRESSURE ENCOUNTERED. PROVIDE SPLIT DUCTLESS AIR—CONDITIONING SYSTEMS AZ 39209 NE A-3547 POLYMER DP 1010, UNITED MCGILL DUCT SEALER OR APPROVED EQUAL, APPLIED OPERATORS WITH SPRING—RETURN FOR NORMALLY CLOSED OR NORMALLY OPEN POSITION CA C-29898 NH 2796 ACCORDING TO SEALANT MANUFACTURER'S INSTRUCTIONS. OUTDOOR DUCTWORK SHALL FOR FAIL SAFE OPERATION TO ACCOUNT FOR FIRE, LOW TEMPERATURES, OR POWER PROVIDE SPLIT DUCTLESS SYSTEM CONSISTING OF EVAPORATOR SECTION FOR WALL CO ARC-400347 NJ AI 09999 BE SEALED TO: SUPPLY — CLASS A, EXHAUST — CLASS C, RETURN — CLASS A. INDOOR INTERRUPTION AS INDICATED. MOUNTING AS INDICATED AND REMOTE CONDENSING SECTION SIMILAR TO MITSUBISHI, CT 9613 NM 004168 DUCTWORK SHALL BE SEALED TO: SUPPLY — CLASS C, EXHAUST — CLASS B, RETURN — DC ARC100723 NV 5521 CLASS C. FUJITSU, FRIEDRICH, DAIKIN OR TRANE. EVAPORATOR CABINET SHALL BE FACTORY DE 0006261 NY 025528-1 NY PROVIDE CIRCUIT BALANCING VALVES MANUFACTURED BY ITT BELL & GOSSETT, ASSEMBLED PRE—WIRED CONSISTING OF FURNITURE—GRADE STEEL WITH BAKED—ENAMEL FL AR91629 OK a4895 ARMSTRONG, TOUR & ANDERSSON, NIBCO, GRISWOLD, PRO HYDRONICS OR TACO. VALVE FINISH, FRONT ACCESS, WITH DIRECT—DRIVE CENTRIFUGAL FANS, 2—SPEED MOTOR, AND GA RA011075 OH 13761 PROVIDE RADIUS ELBOWS, TURNS, AND OFFSETS WITH A MINIMUM CENTERLINE RADIUS SHALL BE RATED FOR 125 PSIG WATER WORKING PRESSURE, 250 DEG F MAXIMUM CLEANABLE FOAM FILTER. EVAPORATOR COIL SHALL BE DIRECT—EXPANSION COOLING COIL HI AR 11489 1 OR 4899 OF 1-1/2 TIMES THE DUCT WIDTH. WHERE SPACE DOES NOT PERMIT FULL RADIUS ELBOWS, OPERATING TEMPERATURE AND SHALL BE BRONZE BODY WITH PLUG OR GLOBE STYLE OF SEAMLESS COPPER TUBES EXPANDED INTO ALUMINUM FINS, WITH THERMAL— IA 05713 PA RA-015 3 —B PROVIDE SHORT RADIUS ELBOWS WITH A MINIMUM OF TWO CONTINUOUS SPLITTER VALVE AND CALIBRATED ORIFICE OR VENTURI. PROVIDE WITH CONNECTIONS FOR EXPANSION VALVE WITH EXTERNAL EQUALIZER. AIR—COOLED CONDENSER SHALL BE OF ID AR-984459 PR 19965 VANES. VANES SHALL BE THE ENTIRE LENGTH OF THE BEND. PROVIDE MITERED ELBOWS PORTABLE DIFFERENTIAL PRESSURE METER WITH INTEGRAL CHECK VALVES AND SEALS. CORROSION—RESISTANT CABINET CONTAINING COMPRESSOR, COPPER—TUBE ALUMINUM— IL 001-019152 RI 2666 WHERE SPACE DOES NOT PERMIT RADIUS ELBOWS, WHERE SHOWN ON THE DRAWINGS, OR VALVE SHALL HAVE INTEGRAL POINTER AND CALIBRATED SCALE TO REGISTER DEGREE OF FIN COILS, DIRECT—DRIVE PROPELLER FANS WITH MOTORS WITH INTERNAL OVERLOAD IN AR10400066 SC 6834 AT THE OPTION OF THE CONTRACTOR WITH THE ENGINEER'S APPROVAL. MITERED ELBOWS VALVE OPENING. VALVE SHALL HAVE POSITION INDICATION READOUT AND BUILT—IN KS 4674 SD 11532 LESS THAN 45 DEGREES SHALL NOT REQUIRE TURNING VANES. MITERED ELBOWS 45— PROTECTION; CAPACITY CONTROL TO 0 DEG F. KY 5967 TN 101374 MEMORY STOP FOR REPEATABLE REGULATION AND CONTROL. VALVES 2 INCH AND LA 5734 TX 17680 DEGREES AND GREATER SHALL HAVE SINGLE THICKNESS TURNING VANES OF SAME GAUGE SMALLER SHALL HAVE THREADED CONNECTIONS AND 2-1/2 INCH VALVES SHALL HAVE PROVIDE REFRIGERANT PIPING SIZED AS RECOMMENDED BY EQUIPMENT MANUFACTURER ME ARC 2596 UT 5881358-0301 AS DUCTWORK, RIGIDLY FASTENED WITH GUIDE STRIPS IN DUCTWORK. VANES FOR FLANGED CONNECTIONS. WITH FOAMED PLASTIC INSULATION ON THE SUCTION LINE AS SPECIFIED IN THIS SECTION. MD 11016 VT 2572 MITERED ELBOWS SHALL BE PROVIDED IN ALL SUPPLY AND EXHAUST DUCTWORK AND IN MA 10635 VA 0401 011223 RETURN AND OUTSIDE AIR DUCTWORK THAT HAS AN AIR VELOCITY EXCEEDING 1000 FPM. PROVIDE Y—TYPE STRAINERS RATED FOR 125 PSIG WORKING PRESSURE AND WITH CONTROL SYSTEM: UNIT—MOUNTED PANEL WITH CONTACTORS, CONTROL TRANSFORMER MI 1301052379 WA 10344 PERFORATED TYPE 304 STAINLESS STEEL BASKET AND BOTTOM DRAIN CONNECTION. WITH CIRCUIT BREAKER, SOLID—STATE TEMPERATURE— AND HUMIDITY—CONTROL MODULES. MN 44326 WI 9900-005 DUCTS SHALL BE CONNECTED TO FANS, FAN CASINGS, AND FAN PLENUMS BY MEANS OF SCREEN OPENINGS SHALL BE 20 MESH FOR 2" AND SMALLER, 1/16" PERFORATIONS FOR 2— MO A-2005029740 WV 3727 FLEXIBLE CONNECTORS. FLEXIBLE CONNECTORS SHALL BE NEOPRENE COATED GLASS 1 2" TO 4" AND 1 8" PERFORATIONS FOR LARGER THAN 4". FOR 2-1/2" AND LARGER, PROVIDE SOLID—STATE, UNIT—MOUNTED CONTROL PANEL WITH START—STOP SWITCH, MS 3860 WY C-1967 CLOTH CANVAS CONNECTIONS, DURO—DYNE, ELGEN, VENTFABRIC OR EQUAL. FLEXIBLE / / ADJUSTABLE HUMIDITY SET POINT, AND ADJUSTABLE TEMPERATURE SET POINT. REFER TO Protessianalseal. PROVIDE CAST—IRON BODY (ASTM A 126, CLASS B), FLANGED ENDS, AND BOLTED COVER. SEQUENCE OF OPERATION. CONNECTORS SHALL HAVE A FLAME SPREAD OF 25 OR LESS AND SMOKE DEVELOPED FOR 2" AND SMALLER, PROVIDE CAST BRONZE (ASTM B 62) BODY, THREADED ENDS AND RATING NOT HIGHER THAN 50. MAKE AIRTIGHT JOINTS AND INSTALL WITH MINIMUM 1— SCREWED COVER. REFRIGERANT PIPING AND INSULATION Ep pR� 1/2" SLACK. `t�(', F;3 PROVIDE THERMOMETERS (GENERAL) WITH ACCURACY OF PLUS OR MINUS 1 PERCENT OF PROVIDE ASTM B 88, TYPE L OR ASTM B 280, TYPE ACR HARD DRAWN COPPER ��5 �tJGINEF9 0/',) PROVIDE BALANCING DAMPERS, MANUFACTURED BY RUSKIN, GREENHECK, NAILOR RANGE SPAN OR PLUS OR MINUS ONE SCALE DIVISION TO MAXIMUM OF 1.5 PERCENT OF REFRIGERANT PIPING, CLEANED AND SEALED AT THE FACTORY, AND SPECIFICALLY v� INDUSTRIES, CESCO, LOUVERS & DAMPERS, POTTORFF OR APPROVED EQUAL, WHERE RANGE SPAN. TEMPERATURE RANGE FOR CHILLED WATER SERVICE SHALL BE 30 TO 240 DESIGNED FOR REFRIGERANT. FITTINGS SHALL BE HARD DRAWN AND HAVE LONG RADIUS 84242PE SHOWN ON DRAWINGS AND WHEREVER NECESSARY FOR COMPLETE CONTROL OF AIR DEG WITH 2—DEGREE SCALE DIVISIONS (0 TO 115 DEG C WITH 1—DEGREE SCALE DIVISIONS); TURNS. SOLDER JOINTS WITH "SILFOS" (15 PERCENT SILVER, 5 PERCENT PHOSPHORUS, 80 FLOW. SPLITTER DAMPERS SHALL BE CONTROLLED BY LOCKING QUADRANTS; PROVIDE HEATING WATER SHALL BE 30 TO 300 DEG WITH 2—DEGREE SCALE DIVISIONS (0 TO 150 DEG PERCENT COPPER, 1300 DEGREES FAHRENHEIT FLOW TEMPERATURE). SOLDER JOINTS WITH YOUNG REGULATOR OR VENTLOK END BEARINGS FOR THE DAMPER ROD. RECTANGULAR C WITH 1—DEGREE SCALE DIVISIONS). A SLOW STREAM OF DRY NITROGEN PASSING THROUGH THE PIPING. VOLUME DAMPERS SHALL BE OPPOSED BLADE INTERLOCKING TYPE. ROUND VOLUME OR DAMPERS SHALL BE BUTTERFLY TYPE CONSISTING OF CIRCULAR BLADE MOUNTED TO A PROVIDE BRASS OR STAINLESS STEEL THERMOWELLS, PRESSURE RATED TO MATCH PIPING INSULATE SUCTION LINES WITH 1" FOAMED PLASTIC INSULATION WITH A MINIMUM ��Y,73 �y SHAFT. DAMPER LEAKAGE FOR OUTSIDE AIR DAMPERS SHALL NOT EXCEED 4.0 SYSTEM DESIGN PRESSURE; WITH 2—INCH EXTENSION FOR INSULATED PIPING AND CONDUCTIVITY OF 0.22-0.28 (BTU*IN)/(HR*SF*'F), ARMAFLEX OR EQUAL. PIPING CFM/SQUARE FOOT IN FULL CLOSED POSITION AT 1" WG PRESSURE DIFFERENTIAL ACROSS THREADED CAP NUT WITH CHAIN PERMANENTLY FASTENED TO WELL AND CAP. INSTALL IN INSULATION SHALL HAVE A FLAME SPREAD OF 25 OR LESS, AND A SMOKE DEVELOPED DAMPER. REFERENCE MANUFACTURER AND MODEL NUMBER FOR OUTSIDE AIR DAMPERS PIPING TEE WHERE THERMOMETERS ARE INDICATED, IN VERTICAL POSITION. FILL WELL RATING OF 50 OR LESS WHEN TESTED IN ACCORDANCE WITH ASTM E84. COAT INSULATION IS RUSKIN MODEL CD-50. PROVIDE FLEXMASTER MODEL STO OR EQUAL 45 DEGREE WITH OIL OR GRAPHITE AND SECURE CAP. THAT IS EXPOSED TO THE ELEMENTS WITH A PROTECTIVE SEALER. INSTALL AND SUPPORT EXP1 RECTANGULAR/ROUND SIDE TAKEOFF FITTING WITH MODEL SLBO DOUBLE BEARING PIPING TO KEEP NOISE AND VIBRATION TO A MINIMUM. SUPPORT AND SECURE PIPING TO DAMPER WITH INSULATION BUILD OUT FOR ROUND DUCTWORK BRANCH TAKEOFFS TO PROVIDE GENERAL USE PRESSURE GAUGES, ASME 840.1, GRADE A, PHOSPHOR BRONZE UNISTRUT TYPE SUPPORTS SO THAT NO VIBRATION PASSES TO THE BUILDING STRUCTURE. co 'lta INDIVIDUAL AIR DEVICES. OMIT DAMPER AT TAKEOFF FITTING WHEN DAMPER IS LOCATED BOURDON—TUBE TYPE, BOTTOM CONNECTION; CASE OF DRAWN STEEL OR BRASS, GLASS PIPE ATTACHMENTS SHALL BE COPPER—PLATED OR HAVE NONMETALLIC COATING FOR DOWNSTREAM OF TAKEOFF. LENS, 4-1/2—INCHES DIAMETER; CONNECTOR OF BRASS, 1/4—INCH NPS; SCALE SHALL BE ELECTROLYTIC PROTECTION WHERE ATTACHMENTS ARE IN DIRECT CONTACT WITH COPPER WHITE COATED ALUMINUM, WITH PERMANENTLY ETCHED MARKINGS; ACCURACY OF PLUS TUBING. INSTALL A SUPPORT WITHIN ONE FOOT OF EACH CHANGE OF DIRECTION. MOUNT WHERE ACCESS TO DAMPERS THROUGH A HARD CEILING IS REQUIRED, PROVIDE A OR MINUS 1 PERCENT OF RANGE SPAN, 2 TIMES OPERATING PRESSURE; SYPHON OF 1/4— PIPE HANGERS AROUND THE OUTSIDE OF THE INSULATION WITH SADDLES TO PREVENTMETHENDERSON CONCEALLED C BOPOLITAN I E OPERAOEDGVOLUUMELDAMP ROWITHEQUAL REMOTEYOPOERATOR.RED DAMPER INCH NPS SNUBBER OFRA14H INCHLNPSSNBRASSTED OF BUSHINGRASS TUBING WTH CORROSOINH RESITHRSTANT POROUS METAL DS ON EACH END; HANGERS FROM RUPTURING THE INSULATION. REPLACE INSULATION THAT IS CUT OR ENGINEERSM SHALL BE ADJUSTABLE THROUGH THE DIFFUSER FACE OR FRAME WITH STANDARD 1/4" / BROKEN BY THE HANGERS. / DISC. DISC MATERIAL SHALL BE SUITABLE FOR FLUID SERVED AND RATED PRESSURE. rx7j NUTDRIVER OR FLAT SCREWDRIVER. CABLE ASSEMBLY SHALL ATTACH TO DAMPER AS ONE RUN REFRIGERANT LINES PARALLEL AND PERPENDICULAR TO WALL AND FLOOR LINES AND 8345 LENEXA DRIVE,SUITE 300 PIECE WITH NO LINKAGE ADJUSTMENT. POSITIVE, DIRECT, TWO—WAY DAMPER CONTROL PROVIDE TEST PLUGS MANUFACTURED BY PETERSON EQUIPMENT CO., FLOW DESIGN, INC., TO APPEAR STRAIGHT AND IN GOOD ORDER. PITCH SUCTION LINES DOWN SLIGHTLY (1" IN LENEXA,KS 66214 SHALL BE PROVIDED WITH NO SLEEVES, SPRINGS OR SCREW ADJUSTMENTS TO COME MG PIPING PRODUCTS CO., SISCO, WATTS REGULATOR CO. OR EQUAL. TEST PLUGS SHALL 20') TOWARDS THE COMPRESSOR. PROVIDE OIL TRAPS AT THE BASE OF VERTICAL SUCTION TEL 9137425000 Fax 913 742 5001 LOOSE AFTER INSTALLATION. SUPPORT CABLE ASSEMBLY TO AVOID BENDS AND KINKS IN BE NICKEL—PLATED BRASS BODY WITH NEOPRENE CORE MATERIAL, WITH 1/2—INCH NPS RISERS OVER 6 FEET HIGH. www.hei-eng.rcom CABLE. FITTING AND 2 SELF—SEALING VALVE—TYPE CORE INSERTS, SUITABLE FOR INSERTING A 1/8— 1550003152 INCH O.D. PROBE ASSEMBLY FROM A DIAL—TYPE THERMOMETER OR PRESSURE GAUGE. INSTALL LIQUID LINE SIGHT GLASSES IN LIQUID LINES NEAREST THE EXPANSION VALVE. ROUND OR OVAL DUCTWORK SHALL BE SEMCO, UNITED, WESCO OR EQUAL, SHEETMETAL, TEST PLUG SHALL HAVE GASKETED AND THREADED CAP WITH RETENTION CHAIN AND BODY FACTORY MOUNT EXPANSION VALVES WITH THE SENSING BULBS SHIPPED LOOSE. FIELD WITH SMOOTH INTERIOR SURFACE, WITH LOW PRESSURE (DUCT PRESSURE CLASS UP TO OF LENGTH TO EXTEND BEYOND INSULATION. PRESSURE RATING SHALL BE 500 PSIG. MOUNT EXPANSION VALVE BULB AFTER REFRIGERANT PIPING IS COMPLETE (DAMAGE MAY Jab Name and Number. 2015-0131 AND INCLUDING 2" W.G.) ROUND DUCTWORK GAUGES PER THE FOLLOWING TABLE (REFERENCE SMACNA HVAC DUCT CONSTRUCTION STANDARDS FOR GAUGES WHEN FLEXIBLE DUCT OCCUR IF BULBS COME IN CONTACT WITH HEAT). PRESSURES EXCEED 2" W.G.): LOW PRESSURE (DUCT PRESSURE CLASS UP TO AND INCLUDING 2" W.G.) AND MEDIUM FOR SYSTEMS OF 5 TON CAPACITY AND SMALLER, THE CONTRACTOR SHALL HAVE THE Proposed SIZE DUCT GAUGE FITTING GAUGE PRESSURE (DUCT PRESSURE CLASS 2.1" TO 6' W.G.) FLEXIBLE DUCT SHALL BE FLEXMASTER OPTION TO PROVIDE COPPER REFRIGERANT TUBING LINE SET SIZED AS RECOMMENDED BY EQUIPMENT MANUFACTURER AND OF LENGTH AS REQUIRED FOR THE INSTALLATION. 14" & UNDER 26 24 TYPE 8TYPE G—KM, M—KE, OR EQUAL (FIRE RETARDANT POLYETHYLENE) PROVIDE 1" THICK FOAMED PLASTIC INSULATION, ARMAFLEX OR EQUAL, ON THE SUCTION VERIZON 15" THRU 26" 24 22 PROTECTIVE VAPOR BARRIER, U.L.181 CLASS 1, ACOUSTICAL INSULATED DUCT, R— LINE. PROVIDE QUICK—CONNECT FLARE TUBING COMPRESSION FITTINGS OR SOLDER 28" THRU 36" 22 20 6.0FIBERGLASS INSULATION. PROVIDE CPE LINER WITH STEEL WIRE HELIX MECHANICALLY LOCKED OR PERMANENTLY BONDED TO THE LINER. CONNECTIONS AS REQUIRED TO MATCH THE CONNECTIONS OF THE CONDENSING UNIT STORE LINDAB SPIROSAFE, LEWIS & LAMBERT OR APPROVED EQUAL FACTORY—MANUFACTURED AND EVAPORATOR COIL. ROUND DUCTWORK AND FITTINGS MAY BE SUBSTITUTED FOR SPECIFIED ROUND BRANCH FLEXIBLE DUCT RUNS SHALL NOT EXCEED 5 FEET IN LENGTH, AND SHALL BE INSTALLED 15A 4 TEMPERATURE CONTROLS (LEED) DUCTWORK, AT CONTRACTORS OPTION. HEAVY LIQUID JOINT SEALANT MAY BE OMITTED FULLY EXTENDED AND STRAIGHT AS POSSIBLE AVOIDING TIGHT TURNS. INSTALL FLEXIBLE ON FACTORY—MANUFACTURED ROUND DUCTWORK. DUCT IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. SUPPORT FLEXIBLE DUCT GENERAL REQUIREMENTS AT MAXIMUM 5 FEET ON CENTER AND WITHIN 6 INCHES OF BENDS. BENDS SHALL NOT LOW PRESSURE (DUCT PRESSURE CLASS UP TO AND INCLUDING 2" W.G.) FITTINGS 24" IN EXCEED A CENTERLINE RADIUS OF ONE DUCT DIAMETER. DUCT SAG SHALL NOT EXCEED 1/2 EQUIPMENT SUPPLIER SHALL PROVIDE A SYSTEM OF TEMPERATURE CONTROLS INCLUDING DIAMETER AND LESS SHALL BE PREFABRICATED, SPOTWELDED AND INTERNALLY SEALED. INCH. SUPPORTING MATERIAL IN DIRECT CONTACT WITH THE DUCT SHALL NOT BE LESS THERMOSTATS, CONTROL PANELS, TIME SWITCHES, OVERRIDE TIMERS, DAMPER MOTORS, CONTINUOUSLY WELD FITTINGS LARGER THAN 24" IN DIAMETER. FITTING GAUGE SHALL BE THAN 1-1/2 INCHES IN WIDTH. AND RELAYS REQUIRED TO PROVIDE THE DESIRED SEQUENCE OF OPERATION. PROVIDE 22 GAUGE FOR 36" FITTINGS AND UNDER, 20 GAUGE FOR LARGER SIZES. 90 DEGREE TEE'S INTEGRATED WIRING DIAGRAMS SHOWING INTERCONNECTIONS BETWEEN FIELD SHALL BE CONICAL TYPE. SEAL LONGITUDINAL AND TRANSVERSE DUCTWORK JOINTS CONNECT FLEXIBLE DUCT TO RIGID METAL DUCT OR AIR DEVICES AS RECOMMENDED BY kbAddress INSTALLED EQUIPMENT AND PACKAGE WIRING FURNISHED WITH THE HVAC EQUIPMENT AIRTIGHT WITH HEAVY LIQUID SEALANT APPLIED ACCORDING TO MANUFACTURER'S THE MANUFACTURER. AT A MINIMUM, INSTALL TWO WRAPS OF DUCT TAPE AROUND THE . INSTRUCTIONS. PROVIDE GAUGE THICKNESS IN MEDIUM PRESSURE (DUCT PRESSURE CLASS INNER CORE CONNECTION AND A METALLIC OR NON—METALLIC CLAMP OVER THE TAPE EQUIPMENT SUPPLIER SHALL PROVIDE SUPERVISION AND ON—JOB CHECKOUT SERVICE AS Washington Square Mall 3" TO 6" W.G.) DUCTWORK AS RECOMMENDED BY SMACNA. AND TWO WRAPS OF DUCT TAPE OR A CLAMP OVER THE OUTER JACKET. DUCT CLAMPS REQUIRED TO ENSURE THAT INSTALLATION MEETS REQUIREMENTS OF THE SPECIFICATION. 9585 S.W. Washington SHALL BE LABELED IN ACCORDANCE WITH UL-181B AND MARKED 18113—C. DUCT TAPE THE SYSTEM SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FOLLOWING THE Square Road 15A HYDRONIC PIPING AND INSULATION SHALL BE LABELED IN ACCORDANCE WITH UL 181B AND MARKED 181B—FX. ACCEPTANCE OF THE SYSTEM BY THE ARCHITECT ENGINEER. CORRECT DEFECTS 3 OCCURRING DURING THIS PERIOD AT NO ADDITIONAL AL COST TO THE OWNER. Portland, OR 97223 o FOR 2 AND SMALLER, PROVIDE HYDRONIC PIPING OF TYPE L HARD COPPER, ASTM B-88 AIR DEVICES Space R05-R07 WITH WROUGHT COPPER FITTINGS, ANSI 816.22 WITH SOLDER JOINTS. INSTALL DIELECTRIC TEMPERATURE CONTROLS SHALL BE LABELED WITH ASSOCIATED HVAC UNIT AND a UNIONS WHEREVER DISSIMILAR PIPING IS JOINED. AT CONTRACTORS OPTION, SCHEDULE PROVIDE AIR DEVICES AS SCHEDULED ON DRAWINGS, MANUFACTURED BY CARNES, E.H. to 40, ASTM A 53, GRADE B, BLACK STEEL WITH WELDED OR SCREWED FITTINGS MAY BE USED. PRICE, KRUEGER, NAILOR INDUSTRIES, TITUS, OR TUTTLE & BAILEY. SELECT AIR DEVICES TO INSTALLED PER MANUFACTURER'S SPECIFICATIONS INCLUDING LOCATING THE UNITS ON M SURFACES THAT ARE NOT EXPECTED TO EXPERIENCE RAPIDLY CHANGING TEMPERATURES. Dra.ingMv. o LIMIT ROOM NOISE LEVEL TO NO HIGHER THAN NC-30 UNLESS OTHERWISE SHOWN. CONTROLS SHALL BE CAPABLE OF MAINTAINING TIME AND SETTINGS DURING A 10—HOUR MECHANICAL 0 INSTALL PIPING PARALLEL TO THE BUILDING LINES UNLESS INDICATED OTHERWISE. PROVIDE DEVICES WITH A SOFT PLASTIC CASKET TO MAKE AN AIRTIGHT SEAL AGAINST THE POWER OUTAGE. cc to SUPPORT AND ANCHOR PIPING AS REQUIRED TO FACILITATE EXPANSION AND MOUNTING SURFACE. COORDINATE FINAL LOCATION, FRAME, AND MOUNTING TYPE OF SPECIFICATIONS CONTRACTION, AND TO PREVENT THE TRANSMISSION OF NOISE AND VIBRATION. AIR DEVICES WITH ARCHITECTURAL REFLECTED CEILING PLANS. TEMPERATURE CONTROLS SHALL BE CALIBRATED TO +/— 2°F. w INSTALL PIPING CONCEALED EXCEPT IN UNFINISHED AREAS. INSTALL PIPING AS REQUIRED PROVIDE CEILING SUPPLY AIR DIFFUSERS AND RETURN AIR GRILLES OF LAY—IN OR SURFACE Q TO MEET CONSTRUCTION CONDITIONS AND ALLOW FOR THE INSTALLATION OF OTHER MOUNTED TYPE AS REQUIRED TO BE COMPATIBLE WITH CEILING CONSTRUCTION. PROVIDE TEMPERATURE CONTROLS SHALL HAVE ALL LOCAL CONTROLS DISABLED OR A LOCKABLE :fCOVER MOUNTED AROUND THEM. Q Oo WORK INCLUDING AIR DUCTS, ELECTRICAL CONDUIT AND LIGHT FIXTURES. INSTALL THE CEILING DIFFUSERS AND GRILLES WITH WHITE ENAMEL FINISH UNLESS NOTED OTHERWISE. CN HORIZONTAL PIPING AS HIGH AS POSSIBLE TO ALLOW FOR SPECIFIED SLOPE AND EQUIPMENT N COORDINATION WITH OTHER COMPONENTS. INSTALL VERTICAL PIPING TIGHT TO SCREENS I COLUMNS OR WALLS. PROVIDE SPACE TO PERMIT INSULATION APPLICATIONS, WITH 1 MANUFACTURERS AND MODEL NUMBERS ARE LISTED FOR REFERENCE AS TO QUALITY AND INCH CLEARANCE OUTSIDE THE INSULATION. ALLOW SUFFICIENT SPACE ABOVE PROVIDE SCREENS ON LOUVERS, DUCTS, HOODS, FANS, AND OPENINGS TO THE OUTDOORS Drawn By Arrow.N FEATURES REQUIRED FOR THE CONTROL DEVICES. PROVIDE CONTROL DEVICES BY BARBER— REMOVABLE CEILING PANELS TO ALLOW FOR PANEL REMOVAL. ARRANGE WATER SYSTEMS AS SCHEDULED AND/OR NOTED ON THE DRAWINGS. BIRD SCREENS SHALL BE 0.041—INCH, COLMAN, HONEYWELL, JOHNSON CONTROLS, TRANE, OR WHITE RODGERS WITH QUALITY checked By N a SO THAT THE ENTIRE BUILDING CAN BE DRAINED. PROVIDE A 3/4" DRAIN VALVE WITH 1/2—INCH MESH GALVANIZED STEEL WIRE. HOSE END CONNECTION AT EACH LOW POINT. INSTALL VALVES WHERE SHOWN AND AND FEATURES AS INDICATED. a I WHERE NECESSARY FOR CUT—OFF, FOR BALANCING AND FOR CONTROL. INSTALL REDUCING EXHAUST AIR SYSTEMS DatelssuedFor FCU-1 AND FCU-2 Client 12/24/2015 FITTINGS AT LINE SIZE CHANGES. PROVIDE ECCENTRIC REDUCERS WHERE APPROPRIATE FOR DRAINAGE. PROVIDE DIELECTRIC FITTINGS WITH APPROPRIATE END CONNECTIONS SEVEN DAY PROGRAMMABLE, OCCUPIED/UNOCCUPIED THERMOSTATS FOR Landlord; i2a4/2015 PROVIDE CEILING MOUNTED EXHAUST FANS AS SCHEDULED ON THE DRAWINGS, OR EQUAL CONTROL OF MULTIPLE STAGES OF HEATING AND COOLING SYSTEMS SHALL BE FOR THE PIPE MATERIALS IN WHICH INSTALLED (SCREWED, SOLDERED, OR FLANGED), COOK, GREENHECK, CARNES, TWIN CITY FANS, ACME OR PENNBARRY COMPLETE WITH Permit; �j24/2015 12 cn WHICH EFFECTIVELY ISOLATE DISSIMILAR METALS, PREVENT GALVANIC ACTION, AND STOP ISOLATED BLOWER UNIT AND CEILING GRILLE. PROVIDE DISCONNECT SWITCH, BACKDRAFT HONEYWELL SERIES T88220 OR EQUAL. INSTALL THERMOSTATS AT 48" AFF TO o Z CORROSION. BRANCH CONNECTIONS SHALL BE FROM THE TOP OR SIDE OF THE MAIN DAMPER, DISCHARGE DUCT, ROOF JACK, AND NEOPRENE VIBRATION ISOLATORS WITH ALL— MEET ADA REQUIREMENTS UNLESS OTHERWISE NOTED ON THE PLANS. Bid: O 0 Construction: PIPING. THREAD HANGING RODS. Revision Ismw.. RTU-3 PROVIDE HANGER RODS OF THE REQUIRED LENGTH AND SIZE SUSPENDED FROM INSERTS IN DRAIN PANS No. Date Desertion c�rSEVEN DAY PROGRAMMABLE, OCCUPIED/UNOCCUPIED THERMOSTATS FOR a THE CONCRETE OR SUITABLE STEEL SUPPORTS FASTENED TO THE BUILDING CONSTRUCTION 0 3 SO THAT PIPES ARE PARALLEL AND EVENLY SPACED. PIPE ATTACHMENTS SHALL BE COPPER— DRAIN PANS SHALL SLOPE TOWARDS THE DRAIN OUTLET BY AT LEAST 0.125 INCHES PER CONTROL OF MULTIPLE STAGES OF HEATING AND COOLING SYSTEMS SHALL BE o I PLATED OR HAVE NONMETALLIC COATING FOR ELECTROLYTIC PROTECTION WHERE FOOT. THE OUTLET SHALL BE LOCATED AT THE LOWEST POINT OF THE PAN AND BE SIZED HONEYWELL SERIES TB8220 OR EQUAL. INSTALL THERMOSTATS AT 48" AFF TO ATTACHMENTS ARE IN DIRECT CONTACT WITH COPPER TUBING. INSTALL INSULATION TO PRECLUDE OVERFLOW. FOR UNITS WITH NEGATIVE STATIC DRAW AT THE DRAIN PAN MEET ADA REQUIREMENTS UNLESS OTHERWISE NOTED ON THE PLANS. m SHIELDS AT HANGER AND PIPE LOCATIONS WITH INSULATION INSERTS ON PIPING OF 1" OR RELATIVE TO THE OUTLET, DRAIN LINE SHALL INCLUDE A P—TRAP OR OTHER SEAL TO GREATER TO PROTECT THE INSULATION AND VAPOR BARRIER JACKET. PROVIDE CLEVIS PREVENT INGESTION OF AMBIENT AIR WHILE ALLOWING THE PAN TO DRAIN COMPLETELY. fD to TYPE HANGERS AND SPACE ON 6 FOOT CENTERS FOR PIPE UP TO 1-1/2" AND ON 10 FOOT DRAIN PANS SHALL BE LOCATED DIRECTLY BELOW COILS OR OTHER WATER PRODUCING 15A 5 SEQUENCE OF OPERATION cc - CENTERS FOR 2" PIPE AND GREATER. INSTALL A SUPPORT WITHIN ONE FOOT OF EACH DEVICES. iT r7 `� 0 CHANGE OF DIRECTION. PROVIDE TWO NUTS ON THREADED SUPPORTS TO SECURELY HVAC UNITS (EXCLUDING COMPUTER ROOM UNIT) SHALL SWITCH TO OCCUPIED MODE oto 0 FASTEN THE SUPPORT. 15A 3 HVAC EQUIPMENT ONE HOUR BEFORE DOOR OPEN TIME AND SHALL SWITCH TO UNOCCUPIED MODE ONE HOUR AFTER DOOR CLOSE TIME. z SPECIFIER'S NOTE: KEEP INSULATION OF CONDENSER WATER AND HEAT PUMP WATER ALL HVAC EQUIPMENT SHALL MEET PERFORMANCE REQUIREMENTS OF ASHRAE 90.1-2007 0PIPING TO PROTECT AGAINST CONDENSATION WHEN SYSTEM OPERATES AT AND SHALL BE ENERGY STAR LABELED. ALL NEW HVAC EQUIPMENT SHALL UTILIZE R-410A. FAN COIL UNIT CONTROL N TEMPERATURES LESS THAN 60 F FOR FREE COOLING OR FOR HEATING PURPOSES. > �t DURING OCCUPIED HOURS, OPERATE FAN COIL UNIT SUPPLY FAN CONTINUOUSLY AND OPEN COMMON EQUIPMENT SHALL BE INSTALLED WITH SUFFICIENT WORK SPACE FOR INSPECTION, INSULATE CHILLED WATER PIPING SMALLER THAN 2WITH 1THICK FIBERGLASS AND ROUTINE MAINTENANCE, CLEANING, AND CALIBRATION. OUTDOOR AIR DAMPER TO MAINTAIN MINIMUM VENTILATION. MODULATE CHILLED WATER CONTROL " " CD N VALVES AND CYCLE STAGES OF ELECTRIC HEATING TO MAINTAIN ROOM THERMOSTAT SET POINT (72 C, PIPING 2" AND LARGER WITH 1-1/2" FIBERGLASS INSULATION CONFORMING TO ASTM C547 DEGREES FAHRENHEIT COOLING, 68 DEGREES FAHRENHEIT HEATING). C3 % WITH TYPE I VAPOR BARRIER JACKET CONFORMING TO ASTM C 1136. INSULATE HEATING in WATER PIPING SMALLER THAN 2" WITH 1" THICK FIBERGLASS AND PIPING 2" AND LARGER DURING UNOCCUPIED HOURS, CYCLE THE FAN COIL UNIT SUPPLY FAN AND COOLING OR HEATING Drawing Number: N w 9 WITH 2" FIBERGLASS INSULATION CONFORMING TO ASTM C547 WITH TYPE II JACKET SYSTEM TO MAINTAIN UNOCCUPIED SETBACK TEMPERATURE SET POINTS. COMMON OUTDOOR AIR N CONFORMING TO ASTM C 1136. MANUFACTURE INSULATION IN PREMOLDED SECTIONS DAMPER SHALL BE CLOSED DURING UNOCCUPIED HOURS. WITH A WHITE FIBERGLASS REINFORCED FOIL LAMINATE ALL—SERVICE JACKET. INSULATE FITTINGS AND VALVES AND COVER WITH ZESTON TYPE PREMOLDED PVC COVERINGS. FITTINGS, JACKETS, PVC COVERINGS AND ADHESIVES SHALL NOT EXCEED FLAME SPREAD LEED NOTES PROVIDED IN BOXES FOR CLARITY a a Z RATING OF 25 AND SMOKE DEVELOPMENT RATING OF 50 PER ASTM E 84. a _t M4 cc 21 OF 31 J_ GENERAL ELECTRICAL NOTES: 8 E5 19 1. PROVIDE A SEPARATE CODE SIZED GREEN EQUIPMENT GROUND CONDUCTOR IN ALL CONDUITS AND RACEWAYS CONTAINING LINE VOLTAGE CIRCUITS. FOR 3'-4" 1'-6" 12 6" V-13' 13 ALL 20A CIRCUITS, EQUIPMENT GROUND CONDUCTOR SIZE SHALL MATCH PHASE CONDUCTOR SIZE. FOR CIRCUITS UPSIZED FOR VOLTAGE DROP INCREASE EQUIPMENT GROUNDING CONDUCTOR SIZE PER CODE. (ON ROOF) 3 GRUSI L1 , 10 2. PROVIDE BACK BOX WITH 1/2" CONDUIT TO ABOVE THE ACCESSIBLE 19 CU , L 3 13 I I CEILING AS REQUIRED FOR THE DIVISION 15 WALL MOUNTED HVAC 30/2/NF TEL _� g CONTROLLERS. COORDINATE EXACT LOCATIONS AND OTHER REQUIREMENTS 294 Morris Avenue Springfield,NJ 07081 16 W 63 R 1 109 WITH MECHANICAL DRAWINGS AND THE ENERGY MANAGEMENT SYSTEM Tel: 973.376.441 1 Fax:973.376.8989 Ll R 3'-0" CONTRACTOR PRIOR TO ROUGH-IN. THERMOSTATS, TEMPERATURE SENSORS, www.GruskinGroup.com NJ REG0100-9969-14 N.I.C. 30/2/15/3R I ETC. SHALL BE INSTALLED AT THE SAME ELEVATION AS THE LIGHT 4" MEN'S L1 5 r 1 301 L132 I SWITCHES UNLESS REQUIRED OTHERWISE. BACK BOXES FOR TEMPERATURE This document and the ideas and designs incorporated RESTROOM +�6., SENSORS SHALL BE MOUNTED VERTICALLY. herein,as an Instrument of professional service, Is the Vic property of GRUSKIN ARCHITEMRE+DESIGN,P.C.,and N.I.C. H1 8 12 _ _ _ _ _ 3. ELECTRICAL CONTRACTOR SHALL COORDINATE PLACEMENT OF POWER AND is not to be usedinwhdaorinpan rany otl>erproject 108 10 17 -.- .......................... .— without the written authorization of GRUSKIN ® 45 1 1 14 CENTERED DATA L NSIDEETS ITLOWER CABINETS.H CABINET RACTOR IN ORDER THAT THEY ARE ARCNRECIURE+DESIGN,P.C. EWH 1 43 1 All Rights Reserved L 1 ©2015 Gruskin Architecture+Design,P.C. ' 4. ALL SWITCH AND ELECTRICAL RECEPTACLE HEIGHTS NOTED ON PLANS SHALL RC 3 I BE TO THE CENTERLINE OF THE DEVICE, MOUNTED VERTICALLY, UNLESS Ke Elem1 A. Qmmkh AIA + o' EWH1 ® WOMEN'S OTHERWISE NOTED. AL 5421 MT 2537 + o" 5. ELECTRICAL RECEPTACLES SHALL BE MOUNTED VERTICALLY WITH AK 13167 NC 9961 10 4947 RESTROOM CENTERLINE AT 18" A.F.F., UNLESS OTHERWISE NOTED. AR 3811 ND 1666 4 E5 L1 107 INVENTORY AZ 39209 NE A-3547 EWH 44" 26 6. ELECTRICAL CONTRACTOR SHALL PROVIDE A 1/2" CONDUIT WITH (1) #6 CA C-29898 NH 2796 L 1 10 6 CO ARC-400347 NJ Al 09999 I GROUND CONDUCTOR WITH GREEN INSULATION EXOTHERMICALLY CONNECTED Cj' 9613 NM 004168 MANAGER +4 " oo +44" +54" + 0'L _ _ �® _ _ EF TO NEAREST EFFECTIVELY GROUNDED BUILDING STEEL AND TO TGB WITH 2- DC 9613 723 NV 5521 HOLE COMPRESSION LUG. DE 0006261 NY 025528-1 NY 105 - - -�- 4-- - _ - _ 1 - _ _ _ L 1 16 FL AR91629 OK a4895 _ _ L 39 7. ELECTRICAL CONTRACTOR SHALL PROVIDE TELECOMMUNICATIONS BONDING GA RA011075 0 13761 CONDUCTOR (TBC) CONSISTING OF (1) 1"CONDUIT WITH CONDUCTOR SIZES HI AR 11489 OR 4899 L127 L151 L129 L131 L1 L1 PER CHART BELOW WITH GREEN INSULATION CONNECTING MAIN BUILDING IA AR-9 - -B ANOD GROUND BUS BAR LOCATED IN MAIN ELECTRICAL ROOM TO THE ID AR-984459 PR 19965 28L1 I TELECOMMUNICATIONS GROUNDING BUSBAR (TGB) UTILIZING 2-HOLE IL 001-019152 RI 2666 BREAK AREA COMPRESSION LUGS. LABEL EACH END OF TBC WITH A GROUND WARNING TAG IN AR10400066 SC 6834 L1 (PANDUIT #PT-BGRND OR EQUAL). BOND EACH END OF METAL CONDUIT TO KKY 59 TIN S 4674 SD 11532 H1 L1 RP 103 OPEN OFFICE 4 O 6 2 H1 TBC W/#6 WITH GREEN INSULATION. LA 5734 TX 176804 e ROOM 6 102 17 4 SIZE OF TELECOMMUNICATIONS BONDING CONDUCTOR (TBC): ME ARC 2596 UT 5881358-0301 EF L1 25 L1 E5 0 18 LENGTH<13' (FT) WIRE #6 E (AWG) MA 10635 A MD 11016 Vr 2572 0401 011223 _ MI 1301052379 WA 10344 1 16 335 I L137 1L1 Rp F 1U 21-26' #1 L1 L1 L1 ' #3 MO A-2005029740 WV 3727 005 L1 L1 20 L1 57 16 27-33' #2 MS 3860 WY C-1967 21 1 1WA 11)L1 1$ 34-41' #1 - 0040 060 010 U 53-66' #tip 1 +25° +25" 5 J 18 1 +25" + 5 1 +25" FCFrotessionalseal: �0 PROF L1 (PART) RD I >66 #3/0 (PA 4----- - - ------ -------- - L --- - -- - ------ ------ 8. VERIZON DATA CABLE VENDOR SHALL PROVIDE AND INSTALL AN ANSI-J-STD � v 2'-3" - 1 2 E5 EQ. EQ. 2'-3" - 1 2 `. 607A COMPLIANT U.L. LISTED TELECOMMUNICATIONS GROUND BUSBAR (TGB) 17547PE r �� 5 COMPLETE WITH STANDOFF BRACKET, INSULATORS, AND ALL FASTENERS (BY (PART 1 (TYP) i 1 E5 T I +2 CHATSWORTH #40156-012 OR HARGER GBI1426G). Z ,� L1 I I E5 (NP) OL GREG N L1 3 II II I L1 L1 1(PART) 3� 'II +z5 9. VERIZON WIRELESS DATA CABLING VENDOR SHALL PROVIDE AND INSTALL A C' SMB 15 a, 13(PART) II ,� `� #6 WITH GREEN INSULATION INDIVIDUALLY TO EACH DATA EQUIPMENT 'Q9/� E ��P — _ — PART)13 — _ __ — — — — RACK/CABINET, OVERHEAD LADDER TRAY/LADDER RACK, R , --- i- I EF_ ___ I �" �.�, L1 N TELECOMMUNICATIONS CONDUIT, TELECOMMUNICATIONS CABLE TRAY(S), vi 3 I ���•.� 19 ANTI STATIC TILE GROUNDING POINTS ETC. AS REQUIRED. CONNECTIONS EXPI S: 1 1/2016 L1 --� I I1 L LII I�_ L ,�' `� (PART)13 SHALL BE MADE WITH 2 HOLE COMPRESSION CONNECTORS. ALL CONNECTIONS17 I I SHALL BE BARE METAL TO BARE METAL USING APPROPRIATE ANTIOXIDANT + 01' L � ' 9'-9 1 2" L---J O ,� L1 Consultant i 4 8'-0' T-1" � 7'-8" � N 3 COMPOUND. E5 16 5 j �� E5 10. ALL TELCO POWER/DATA SHALL BE VERIFIED WITH VERIZON REGIONAL IT. E5 I (�,P) � 11'-6 1/2" g'-g" 11. NOTE: DATA WIRING IS TO BE PROVIDED BY VERIZON WIRELESS AND IS --" II I NOT THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. ALL DATA WIRING HENDERSON - 15L1 0 9 IN WALLS SHALL BE RUN IN A 1" CONDUIT TO 6" ABOVE SUSPENDED CEILING. ENGINEERS ,7" I �i 3 L1 8345 LENEXA DRIVE,SUffE 300 •��;� I' 1 �2" RETAIL SALES ELECTRICAL PLAN NOTES: ` I 101 ' '' _ +, TEL 913 742 5000 FAX 913 742 5001 z„+,I” 5 E� I �� C E I = LENEXA, 66214 [E] www.hei-eng.�om _ 2 *�° ❑1 CIRCUIT CONTROLLED THROUGH RELAY PANEL. REFER TO PANELBOARD J \�W 15 5 __� ___ E5a 5 ``W'' E5 SCHEDULES ON SHEET E3 AND DETAIL 1/E4 FOR SWITCHING AND CLOCK 1550003152 9'-2' E5 3 ( II AUTOMATION SCENARIOS SCHEDULE. (NP) II II 18 0 II 2RECEPTACLE, FLUSH IN CEILING, ABOVE STORE WINDOW, FOR SHOW WINDOW bb Name and Number. 2015-0131 DISPLAY UNITS. OUTLETS TO BE PARALLEL TO STOREFRONT. COORDINATE II I E5 5 EXACT LOCATION WITH ARCHITECT. _ _ __ Proposed j i o �3 PROVIDED (1) 1" CONDUIT, WITH CONDUCTORS FOR POWER AND (1) 1" `o `� - -- a' ,' CONDUIT, WITH PULL STRING FOR DATA. ALL CONDUITS UNDER SLAB. VERIZON DATA STUBBED UP IN WALL TO 6" ABOVE CEILING LINE. PROVIDED WITH 14 •� o / I o f� END BUSHING. REFER TO DETAIL 11/SHEET E5. 5 E5 / j STORE 3 / j ® JUNCTION BOX FOR CONTINUOUS PLUGMOLD STRIP. LOAD CALCULATED AS (nP) �' /•� — J j ��� �;• 180VA/5LF PER CODE. REFER TO DETAIL 10/SHEET E5. •• ` �5 STUB UP CONDUITS TO FLOOR MOUNTED, STEEL MASONRY J-BOX FOR POWER (LEED) ` \ 3 I AND DATA. CONNECT TO PREWIRED FURNITURE DEVICE WITH FIXTURE WHIP. \ •' •' 3'-0" 3'-0" i o0 `. / REFER TO POWER AND DATA FIXTURE SCHEDULE ON THIS SHEET FOR 8'-4 1/2" ADDITIONAL INFORMATION. 10'-6 1/2" j ' © COORDINATE WALL PENETRATION LOCATION WITH VERIZON WIRELESS D •� PROJECT MANAGER, ARCHITECT, AND SIGN MANUFACTURER. MAKE ALL FINAL kbAddress j �/ (PART)131 CONNECTIONS TO EXTERIOR SIGNAGE. Washington Square Mali 2'-10" 8'-10" 17 5 �7 J-BOX, ABOVE ACCESSIBLE CEILING, WITH LOCAL PAD-LOCKABLE-OFF 9585 S.W. Washington j E5 o DISCONNECT SWITCH, FOR EXTERIOR SIGNAGE, SHALL CONTAIN (1) 120-V, Square Road 0 20-AMP CIRCUIT. ALL BRANCH CIRCUIT WIRING TO THE SIGN SHALL BE q (TYP) PER UL2161 FOR GFCI SIGN TRANSFORMERS. UL2161 REQUIRES THAT ALL Portland, OR 97223 o i CIRCUITS SHALL HAVE A DEDICATED HOT, NEUTRAL, AND GROUND Space R05-R07 TERMINATING AT THE ELECTRICAL PANELBOARD. COORDINATE WITH N I I I VERIZON WIRELESS PROJECT MANAGER. 0 41 j ® REFER TO GENERAL ELECTRICAL NOTES 7 THRU 10 ON THIS SHEET FOR DrawingMt1: o L1 ADDITIONAL INFORMATION ON TELCO M. ELECTRICAL cc > LID —r_ LO 13(PART)— 2 — 2 — — — C 2 — 2 — — 2 — — F9 4'-0" LONG, �4" CONDUIT WITH BUSHINGS AT EACH END. CONDUIT SHALL POWER PLAN 2 / I EXTEND 2'-0" ABOVE AND BELOW CEILING. PROVIDE SUPPORT FOR CONDUIT 2 J j ( FROM STRUCTURE AS NECESSARY. REFER TO DETAIL 12/SHEET E5. a o - - - - - - - - - - - - - - - - - - - - j - - - - - - - - - - - - - - - - - - - - 10 ROUTE NEW 2" CONDUIT FROM 24" BELOW CEILING AT LOCATION SHOWN TO c o — — — — — — — — ———-- 1-1 ———� — — — — — — — BUILDING SERVICE TELCO LOCATION. FIELD VERIFY LOCATION OF m - - - - - - - - - - - - - - - - - - — ----------- - - - - - - - o �I 12 © EXISTING CIRCUITRY. COORDINATE REQUIRED NUMBER OF PAIRS WITH co I 1 7 VERIZON WIRELESS. Drawn By: North 0 DEDICATED PER FR SECURITY 1 1 REQUIREMENTOSWWITH OEQUIPMENT SUPPLIER.EQUIPMENT. COORDINATE EXACT Chocked By LKV �"�` N 12 PROVIDE (1) ONE DEDICATED 20 AMP 120V DUPLEX RECEPTACLE Date t�uedFor AJ0 0I (HBL5362GY-GRAY) LABELED "IT ONLY" AT THE RACK. Client- g2J24,/2015 a 13 PROVIDE (1) ONE DEDICATED 30 AMP TWIST LOCK OUTLET 0 +18" A.F.F. Landlord; W POWER PL.f1N N (NEMA L5-30R) LABELED "UPS" AT THE RACK. Permit_12�24/2{115 C11T (n SCALE: 1 je"= -0" Bid: 0 0 14 PROVIDE (1) ONE DEDICATED 20AMP 120V DUPLEX RECEPTACLE LABELED Construction: z "BDA" RECEPTACLE AT 6'-4" A.F.F. FOR BDA REPEATER. PROVIDE ROOF PENETRATION AS REQUIRED. COORDINATE EXACT REQUIRMENTS WITH Revision Issue No. Date Descrolon ,-„ VERIZON WIRELESS CONSTRUCTION MANAGER. 3 15 ABOVE CEILING PER NEC 450.13(8). PROVIDE TRANSFORMER TO BE o I SUPPORTED ABOVE CEILING. SUPPORT FROM STRUCTURE ABOVE. DO NOT '2FIXTURE DATA FEED SCHEDULE INSTALL TRANSFORMER WITHIN WORKING CLEARANCES OF PANELBOARDS F BELOW. C4 Go �2 NUMBER OF 16 RE: DETAIL 1/ SHEET E2 FOR CONTINUATION TO RESTROOM LIGHT DATA FEED FIXTURE NUMBER FIXTURE. CONNECT EXHAUST FAN WITH RESTROOM LIGHT SWITCH SUCH DATA WIRE SYMBOL KEY THAT EXHAUST FAN RUNS WHEN EITHER RESTROOM LIGHT FIXTURE IS "ON". LI' SX-01 SX-02, 8X-06, SX-15, PROVIDE RELAY, CIRCUITRY, ETC. AS NECESSARY. N 1 DATA WIRE(1) DATA FEED 8X_20, SX-21, BPK 17 REFER TO EQUIPMENT SCHEDULE ON SHEET M2 FOR DISCONNECT. a = (CATEGORY 6) 18 PROVIDE DUCT SMOKE DETECTORS IN RETURN DUCTS FOR MECHANICAL EQUIPMENT. (2) DATA FEEDS SX-07, SX-10, SX-22 - 2 DATA WIRES (CATEGORY 6) N — j ' - 19 GFCI RECEPTACLE AT MECHANICAL EQUIPMENT. Lo LO cn (3) DATA FEEDS SX-11, SX-16, SX-23, SX-24 4 DATA WIRES (CATEGORY 6) N g DrawingNumbet: ti Z & NOTE: DATA WIRING IS TO BE PROVIDED BY g NOTE: DATA WIRING IS TO BE PROVIDED BY VERZION WIRELESS VENDOR AND IS NOT THE GENERAL VERZION WIRELESS VENDOR AND IS NOT THE ELECTRICAL C0DE: 2 0 z CONTRACTORS RESPONSIBILITY. REFER TO GENERAL CONTRACTORS RESPONSIBILITY. 2014 O R E G E O N ELECTRICAL SPECIALTY CODE ARCHITECTURAL FIXTURE PLAN FOR FIXTURE NUMBERS. 22 OF 31 J_ 7 ( GENERAL LIGHTING NOTES: ® 1. EMERGENCY LIGHT FIXTURES SHALL BE WIRED IN A NORMALLY "ON" CONFIGURATION UNLESS NOTED OTHERWISE. 2. PROVIDE A CODE SIZE GREEN EQUIPMENT GROUNDING CONDUCTOR FOR ALL LINE VOLTAGE CIRCUITS. GRUSKIN 3. ALL EXTERIOR EGRESS LIGHTING AND EXTERIOR EMERGENCY EGRESS LIGHTING PROVIDED BY LANDLORD. K RESTROOM ®J_j 4. ALL SWITCHES SHALL BE MOUNTED VERTICALLY WITH CENTERLINE AT 44" 294 Morris Avenue Springfield.NJ 07081 ❑ 108 ❑ Q — A.F.F., UNLESS NOTED OTHERWISE. Tel: 9 rusk!n.441 I Fax:97 GOIOO-8489 vvww.GruskinGroup.com NJ REG 0100.9869-14 N.I.C. °S - - 5. GENERAL CONTRACTOR SHALL CONTACT DESIREE DUSTIN OF WEIDENBACH—BROWN ® TELCO _ TO ORDER ALL LIGHTING FIXTURES. COORDINATE WITH VERIZON WIRELESS PROJECT misdocument and the ideas and designs incorporated R MANAGER. herein,as an instrument of professional service, is the —20 I 109 N.I.C. EM F7 property of GRusKIN ARCH rtECiURE+DESIGN,PG . ,and CS-20 . 6. SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR ALL LIGHT isnot to be used In wholeorin partforany other project 4❑ tvhhout the written auttwrizatlon of GRUSKIN-- - FIXTURES/TRACK LOCATIONS. ARCHrrECTr1RE+DESIGN,P.C. All RWtts Reserved 7. LIGHTING SYSTEMS AND CONTROLS WILL BE COMMISSIONED PER THE ©2015GruskinArchitecture+Design,P.C. REQUIREMENTS OF THE COMMISSIONING SECTION OF THE LEED PROTOTYPE I WOMEN S / I GREEN SPECIFICATIONS. KMrNIH 1� aY� 1 AIA ® RESTROOM 8, PRIOR TO COMMENCING WORK ON THE STORE, THE GENERAL CONTRACTOR AL 5421 MT 2537 — SHALL PROVIDE COPIES OF THE COMMISSIONING SPECIFICATIONS ON THE AK 13167 INC 9961 a 107 1666 IN ENTORY LEED PROTOTYPE GREEN SPECIFICATIONS TO THE MECHANICAL, AR 392 ND A-3 547 CR-20 I 061 / ELECTRICAL, PLUMBING, AND CONTROLS SUB—CONTRACTORS. AZ 3929 NE 2796 77B 1 1 11CA C-29898 NH A 0 JNG os 9• CO ARC-400347 NJ Af 09999 CR-20 I REFER TO SHEET E4 FOR LIGHTING CONTROL DEVICE SCHEDULE AND SHEEP CT 9613 NM 004168 E5a FOR LIGHT FIXTURE SCHEDULE. DC W 5521 os oo° L _ _�_ ® – _+__ CS-20 3 DE 00626123 NY 025528-1 NY 11 — — — — — — OCCUPANCY SENSORS: GGA RRAA00111075 off 13761 HI AR 11489 F OR 4899 5 R * Lv OCCUPANCY SENSORS SHALL TIME OUT AT 10 MINUTES FOR THE IA 05713 – –B RESTROOMS AND ALL OTHER SPACES. ID AR-984459 PR 19965 OCCUPANCY SENSORS SHALL BE CAPABLE OF MANUAL ON/AUTOMATIC OFF IL 001-019152 M 2666 1 IN AR10400066 SC 6834 OPERATION. KS 4674 SD 11532 77E /-�q � _ OCCUPANCY SENSORS SHALL BE POSITIONED AND ADJUSTED SO THAT KY 5967 TN 101374 'H1' 'L1' 'RP' os CR-2 == EM SENSOR STATUS INDICATOR BLINKS WHEN ROOM IS OCCUPIED, AND LA 5734 TX 17680 rij ACTIVATES WHEN A PERSON BREAKS THE PLANE OF THE DOORWAY. ME ARC 2596 UT 5881358-0301 CR-20 EM-20 EM 7 1 US OCCUPANCY SENSORS SHALL NOT TURN LIGHT ON WHEN PERSON PASSES MD 11016 VF 2572 104 BREAK AREA — AN OPEN DOORWAY. MI 130 052379 WA MA 10535 VA 10344 401 11223 Ni is I OPEN OFFICE ; CR-20 MN 44326 WI 9900-05 10%L1 102 _ _ ---------------____ ; 5 LIGHTING SEQUENCE OF OPERATIONS: MS 3860°5°2x74° WY 3727 67 I RELAY PANEL SHALL TURN MERCHANDISING LIGHTING SCHEME ON 1 HOUR Professional Sed: BEFORE OPEN DOOR TIME, AND OFF 1 HOUR AFTER DOOR CLOSE TIME. p PROF RELAY PANEL SHALL TURN SALES FLOOR LIGHTING SCHEME ON WHEN SECURITY L1 -- --____-- SYSTEM IS SWITCHED OFF AND OFF WHEN SECURITY SYSTEM IS SWITCHED ON. �`^`� �NC'1 NEER RELAY PANEL SHALL TURN EXTERIOR SIGNAGE ON FROM 6AM — 12AM, AND OFF ---- --- -------- ------- VIA PHOTOCELL OVERRIDE. 1757P -- ---- — -- — ---- -------- --- ---- 2 1 1 _ I _ _ � � `\ 6 R _^' EM LIGHTING PLAN NOTES: 20 GREG --� CR 01 L1 `� Lv s 1 ❑1 MASTER SWITCH LOCATION FOR RETAIL SALES. REFER TO DETAIL 2/ C��FMeL ❑ I EM n SHEET E4 FOR ADDITIONAL INFORMATION. /� P� r v o ^ o �` ❑2 CIRCUIT CONTROLLED THROUGH RELAY PANEL. REFER TO PANELBOARD I-- — �1 I �— — �i ---�i I , SCHEDULES ON SHEET E3 AND SHEET E4 FOR SWITCHING AND ZONING-X EXPI S: 1 /20 CONTROLS. C ^� C I I 0 — —J 0 — --I I p ----I .3 `� `� .: I L_ IN- R- REFER _ L__. 1 _J ❑3 PROVIDE WALL MOUNTED INFRARED OCCUPANCY SENSOR FOR AUTOMATIC ' SHUTOFF CONTROL OF ROOM LIGHTING. REFER TO SHEET E4 FOR LIGHTING Consultant 7 11>0'\\'I', CONTROL DEVICE SCHEDULE. ADJUST OCCUPANCY SENSOR PER LIGHTING SEQUENCE OF OPERATIONS. CR-01 CR 01 __y ® ALL FIXTURES OUTSIDE VERIZON WIRELESS' LEASE SPACE WILL BE BY HENDERSON -- 0 RW 0 o LANDLORD UNLESS NOTED OTHERWISE, INCLUDING ALL NORMAL AND ENGINEERS_ 7EMERGENCY EGRESS AND EXIT LIGHTING REQUIRED PER APPLICABLE N 1 CP-08 �, ` BUILDING CODE. __ ❑5 REFER TO SHEET E4 FOR LIGHTING CONTROL DEVICE SCHEDULE. 8345 LENEXADRIVE,6621 ATE 300 �T O LENEXA,KS 66214 ( RT) Ll CR-02 , – I `��. ` �,;'� I\ PAR 8 1 D TEL 913 742 5000 Fax 913 742 5001 © PROVIDE WATTSTOPPER 8120E–P, (OR APPROVED EQUIVALENT) POWER PACK www.hei-ong.com CP-08 -- WITH CONTROL RELAY FOR USE WITH OCCUPANCY SENSOR AND ADDITIONAL 1550003152 W CR 01 CR-01 — ---- CR 01 CR-01 w CR-01 �CR O1 CR 01 2 RELAYS AS REQUIRED. g o 8 77 PROVIDE BRUCK P70418-700 LED DRIVER OR APPROVED EQUIVALENT) FOR CJl Job Name and Number. � CONTROL OF CP-08 FIXTURES. MAX 3 FIXTURES PER DRIVER. 200-0131 1 CR 01 CR-02 CR-01 0 I CR— 2 8 2A CURRENT LIMITER INTEGRAL TO TRACK. Proposed CR-02 C —02 / ,p\ I ❑9 RE: DETAIL 1/SHEET E1 FOR CONTINUATION TO EXHAUST FAN. VERIZON RETAIL S LES , CR 01 0 1 CR 01 ` '� \ ° 'P� C —01 CR 01 a STO R E 1 I o 4E-5) / o 0 (LEED) ' I CR— 2 CR-02 �� N r 7 u0 \, \\- O kbAddressR-02 �'� rCR01 CR 01 ��� CR-0 CR 01 CR 01 cR_ 2 I Washington Square Mall 9 CR—02 CR 02 5 SSuare Road ( TYP) Washington E5 P) Portland , OR 97223 3 � CR-01a CR-01a Space R05-R07 I ( N LAI C —01 CR 01 DrawingTitte: M X1 o CR-01 CR-01 CR-01 CR-01 ELECTRICAL to - - - - - - - - - - - - - - - LIGHTING PLAN d W W o — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 0CN - - - - - - - - - - - - - - - - - - - - - - - - - - --------- ---- ------- ---- r - - - O 1 Drawn By: L� NAS o p M d' ChKmd w. "a 6 AJO Date Issued For IL I Client 1/24015 3 Landlord; 2/24/2015 N &SC—AF I GH IN G PLAN A' Permit�,2,/24/2015 L1/4"=1'-0" Bid: Z a o Construction: Ln !9z Revislon Issue: No. Date Desalptlon w Q 0 3 0 � I O _rn ~ N m u7 C M cn � c � O L0 L N Z O N_ N � J C) N CD uD Q DrawingNumbar: 'c > = O Ng a- -67 O O WZ X c U zi F3 J_ 7 GRUSKIN W NOTE: CIRCUIT SCHEDULE: UTILITY TRANSFORMER: ALL CONDUCTOR SIZES ARE BASED ON 294 Morris Avenue Springfield,NJ 07081 1000 KVA, 3.5%Z, SECONDARY 480Y/277V, PAD MOUNT 75 DEG C RATED TERMINATION AND COPPER Tel: 973.376.4411 Fax:973.376.8989 AVAILABLE FAULT CURRENT AT SECONDARY IS: CONDUCTORS WITH TYPE THHN/THWN-2 www.GruskinGroup.com NJ REG0100-9869-14 38,230 FCA INSULATION. WHERE ALUMINUM CONDUCTORS F UTILITY TRANSFORMER UTILITY COMPANY: PORTLAND GENERAL ELECTRIC ARE ALLOWED PER SPECIFICATIONS AND This document and the ideas and designs incorporated 480Y/277v, 30, 4W SEC UTILITY CONTACT: JEFF BRADLEY, (503) 323-6700, CONTACTED ON 12/9/2015 FOR TERMINATION OR INSULATION TYPES herein,as an Instrument of professional service, is the FAULT CURRENT SOURCE: INIFINITE PRIMARY RATED LESS THAN 75 DEG C, MODIFYTENANT ELECTRICAL SERVICE LOAD SUMMARY property of GRUSKIN AMITECTURE+DESIGN,P.C.,and UTILITY COMPANY UNABLE TO RELEASE FAULT CURRENT SIZES ACCORDING TO NFPA 70. is not to be used in whole or in part for any other project INFORMATION AT THIS TIME. TENANT OCCUPANCY TYPE: M SERVICE DESCRIPTION: without the written authorization of GRUSKIN F1 PGE WILL NOT RELEASE TENANT INFORMATION WITHOUT AUTHORIZED CONSENT. 73 70A, (3)#4, (1)#8G, 1" C TENANT SQUARE FOOTAGE: 3,389 480Y/277V, 3PH ARCHITECTURE+DESIGN,P.C. All Rights Reserved EXISTING 1600A SERVICE, 1000kVA XFMR WITH A 3.5%Z. LOAD DESCRIPTION Connected Demand Demand Q 2015 Gruskin Architecture+Design,P.C. ASSUMING INFINITE PRIMARY, WITH FCA= 38,230A. T154 150A, (4)#1/0, (1)#6G, 1-1/2" C KVA FACTOR KVA ~ (PER BUSSMANN ELECTRICAL PROTECTION HANDBOOK 'SPD') w 204 200A, (4)#3/0, (1)#6G, 2" C HVAC - SUMMER 2.50 100% 0.00 K1tt1 A. ��� AIA HVAC - WINTER 34.00 100% 34.00 AL 5421 MT 2537 EXIST EXISTING TO REMAIN LIGHTING PER NEC-220 10.17 125% 12.71 AK 13167 NC 9961 G200 GND, #4 COPPER GROUND, 3/4" C RECEPTACLES 15.84 100%;50% 12.92 AR 3811 ND 1666 AZ 39209 NE A-3547 KITCHEN EQUIPMENT 0.00 100% 0.00 CA C-29898 NH 2796 MOTOR LOADS 4.30 100% 4.30 CO ARC-400347 NJ Al 09999 CT 9613 NM F2 MAN SWITCH BOARD (EXISTING) LARGEST MOTOR LOAD 0.00 125% 0.00 C ARC100723 NV 552168 SUPPLEMENTAL ELECTRIC HEAT 0.00 100% 0.00 DE 0006261 NY 025528-1 NY 480Y/277v 30 4W MISCELLANEOUS EQUIPMENT 20.11 100% 20.11 FL AR91629 OK a4895 DISPLAY CASE/SIGNAGE 1.20 125% 1.50 GA RA011075 OH 13761 48 99 1600A SHOW WINDOW TRACK LIGHTING 11.28 PER NEC 13.98 IHAI 00557139 PR RA-R 90 -B TOTAL LOAD 99.40 KVA 99.52 ID AR-984459 PR 19965 3P S-01 M R-0 M R-01 M R-05 M R-11 M R-O M R-09 M R-9 TM R-O M IL 001-019152 RI 2666 (` ❑2 ( ALL ELECTRICAL LOADS TO BE BALANCED TOTAL AMPACITY 119.56 AMPS 119.71 IN AR10400066 SC 6834 F \ 400A ( 1ODA C 1ODA \ 300A 1OOA \1OOA 1OOA 1OOA 1O A WITHIN 10% OF EACH PHASE. SERVICE AMPACITY 200 AMPS 200.00 KS 4674 SD 11532 \ 3P 3P SPARE CAPACITY AMPS 80 K 5767 TTN '0638704 NEUTRAL BUS EXIST ME ARC 2596 UT 5881358-0301 GROUND BUS PANELBOARD: H1 (NEW) FAULT CURRENT: REFER TO ONE-LINE DIAGRAM EQUIPMENT GROUND BUS MD 11016 Vi 2572 EXIST TENANT TENANT TENANT TENANT TENANT TENANT TENANT TENANT MA 10535 VA 0401 011223 BUS AMPS: 225A AIC RATING: REF 1-LINE - - - - - - - - - - MI 1301052379 WA 10344 MAIN SIZE TYPE: 200A MCB SERVES: GENERAL POWER MN 44326 WI 9900-005 N N N v' VOLTS/PHASE: 480Y/277V, 3PH, 4W MOUNTING: SURFACE MO A-2005029740 WV 3727 5<<z w w w w w TO GROUND BAR AT MAIN SECTION: 1 LOCATION: ELEC ROOM 104 MS 3860 WY C-1967 TELEPHONE BOARD (TTB) CKT DESCRIPTION VOLTAMPS PHASE WIRE BKR P P BKR WIRE I VOLTAMPS PHASE DESCRIPTION CKT Professional Seal: TO STRUCTURAL STEEL N NO. A B C NO. AMP AMP N0. A B C NO. 2 ED P R pFFss TO ABOVE GROUND METAL PIPING 1 15,280_ 4,444 �JGINF R �� 3 PNLBD L1 VIA TX-L1 13,175 OL 70 3 3 25 10 4,444 FCU-1 4 F O TO WATER SERVICE F3 14,538 4,444 CC TO BUILDING FOOTING (UFER) (NEW) 7 SPACE 1 4,444 8 17547PE PNLBD H1 9 SPACE 1 3 25 10 4,444 FCU-2 10 TO GROUND ROD(S) 11 SPACE f 1 4,444 12 1- 13 SPACE 1 3,777 14 L OR O �� \ 15 SPACE 1 3 20 12 3,777 FCU-3 16 �1 1/ - 17 SPACE 1 / 3,777 18 19 SPACE 1 1 i SPACE 20 GENERAL ONE-LINE NOTES: 21 SPACE 1 1 SPACE 22 EXPIRES: 31/ r` 23 SPACE 1 1 SPACE 24 1. INFORMATION SHOWN ON TENANT DRAWINGS IS INTENDED TO 25 SPACE 1 1 SPACE 26 INDICATE MINIMUM REQUIREMENTS TO MEET NEED OF TENANT. 27 SPACE 1 1 SPACE 28 Consultant VERIFY EXISTING CONDITIONS, CAPACITIES, AND OTHER 29 SPACE 1 1 SPACE 30 PROVISIONS BY OTHERS PER TENANT LEASE AGREEMENT PRIOR F4 TX-L1 SUBTOTAL 1 15,280 13,175 14,5381 12,665 12,665 12,665 SUBTOTAL TO BEGINING CONSTRUCTION. r- --� 145 kVA TOTAL PHASE A - VA 27,945 LOAD CONN. VA DF LOAD CONN. VA DF HENDERSON 2. ALL CONDUCTOR LENGTHS PROVIDED IN THESE DESIGN DESIGN i 1480/277v AMPS 101 COOLING 2,496 0 REFRIGERATION 1.00 J208/120v - ---- ENGINEERSM ---- - -------------- -- --- ------- DOCUMENTS ARE INTENDED SOLELY FOR USE IN THE DESIGN F5 TOTAL PHASE B- VA 25,840 HEATING 33,999 1.00 SIGN/DISPLAY 1,200 1.25 yj CALCULATIONS BY THE DESIGN PROFESSIONAL UNLESS SPECIFICALLY o AMPS 93 LIGHTING 3,037 1.25 KITCHEN 1.00 NOTED OTHERWISE IN THE DOCUMENTS. THEY SHALL NOT BE USED BY o TOTAL PHASE C - VA 27,203 RECEPTACLES 15,8401.0/.5- EXISTING 1.00 8345LENEXADRIVE,SUfTE300 CONTRACTORS IN BIDDING OR CONSTRUCTION THE PROJECT. THE " ~ LENEXA,KS 66214 AMPS 98 MOTORS 4,304 1.00 LARGE MOTOR 1.25 TOTAL DEMAND CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MATERIAL TEL 913 742 5000 FAx 913 742 5001 TOTAL PNLBD - VA 80,988 SUPP HEAT_ __ 1.00 SHOW WINDOW _ 10,800 1.25 _ 90,61 1 VA QUANTITIES REQUIRED TO BID AND CONSTRUCT THE COMPLETE PROJECT. - AMPS 97 MISC EQUIP 20,112 1.00 LTG TRACK 480 1.00 109 A www•hei-eng.com 3. LANDLORD SHALL VERIFY CAPACITY OF EXISTING SERVICE ENTRANCE PANELBOARD NOTES 1550003152 TO CARRY THIS CALCULATED LOAD PLUS OTHER EXISTING LOADS. F6 ELECTRICAL ONE-LINE NOTES: (NEW) LTG TRACK - TRACK LENGTH bb Name and Number: 2015-0131 PNLBD Ll SIGN DISPLAY - SIGNAGE & DISPLAY CASE F1 CONFIRM THIS IS POINT OF SERVICE ENTRANCE AND Proposed THAT NEUTRAL AND GROUND ARE BONDED TOGETHER AND TO THE GROUNDING ELECTRODE SYSTEM. PANELBOARD: L1 (NEW) FAULT CURRENT: REFER TO ONE-LINE DIAGRAM EQUIPMENT GROUND BUS VE R IZO N BUS AMPS: 225A AIC RATING: FCA +10% MINIMUM, FULLY RATED F2 PROVIDE NEW METER, SWICH AND FUSES FOR TENANT MAIN SIZE/TYPE: 150A MCB SERVES: GENERAL POWER STORE SPACE. COORDINATE METER REQUIREMENTS AND VOLTS/PHASE: 208Y/12OV, 3PH, 4W MOUNTING: SURFACE INSTALLATION WITH LANDLORD. SECTION: 1 LOCATION: ELEC ROOM 104 CKT DESCRIPTION VOLTAMPS PHASE WIRE BKR P P 8KR WIRE I VOLTAMPS/PHASE DESCRIPTION CKT (LEED) NO. A B C I NO. AMP AMP NO. I A B C I NO. 1 RCPT-DISPLAY UNSWITCHED 900 12 20 1 1 20 12 848 LTG-1/2 RETAIL SALES A + EM 2 R,EM 3 RCPT-CASH WRAP A 360 12 20 1 1 20 12 620 LTG-1/2 RETAIL SALES B + EM 4 R,EM 5 RCPT-SMART ZONE TABLE 720 12 20 1 1 20 12 696 LTG-DISPLAY 6 R 7 RCPT-NEW RELEASE/BRAND 900 z12 20 1 1 20 12 228 LTG-TRACK 8 R 9 RCPT-CASH WRAPS B 720 12 20 1 1 20 12 645 LTG-BACK OF HOUSE + EM 10 EM Jab Address 1 No s CTR I CAL 0 N E LINE DIAGRAM 11 RCPT-SMART ZONE CW 1,080 12 20 1 1 20 12 1,200 SIGNAGE 12 R Washington Square Mall 15 RCPT-HOMLE 13 E SOLUTIONS IL GENERAL 900 720 �� 12 20 1 1 20 12 12 20 1 1 20 12 720 720 RCPT-ESSEN SWITCHED B 16 RCPT-ESSEN SWITCHED A 14 R 9585 S.W. Washington 17 RCPT-SERVICE PANEL 500 12 20 1 1 20 12 500 PWR-FOCAL WALL SWITCHED 18 R Square Road 19 RCPT-BILL 3 21 RCPT-MANAG RS ELEOPELINE 860 12 20 1 1 20 12 720 12 20 1 1 20 12 720 720 RCPT-ESSEN SWITCHED D 22 R �P+ortland, OR 97223 0 23 RCPT-BREAKROOM 180 20 20 1 1 20 12 900 RCPT-DISPLAY SWITCHED 24 R Space R05-R07 Mw GF 25 RCPT-WATER COOLER 552 12 20 1 1 20 12 360 RCPT-RESTROOMS 26 U0 27 RCPT-BREAK COUNTER 180 12 20 1 1 20 12 900 RCPT-INVENTORY 28 0 29 RCPT-MICROWAVE 1,200 12 20 1 1 20 12 360 RCPT-SECURITY 30 orawirTme: 0 GF 31 RCPT-FRIDGE 800 12 20 1 1 20 12 500 RCPT-BDA REPEATER 32 ELECTRICAL LO 33 RCPT-PRINTER 800 12 20 1 1 20 12 180 RCPT-MUSIC 34 Ca 35 RCPT-RIC MONITOR 600 12 1 20 1 1 20 12 500 RCPT-IT ONLY 36 ca W 37 RCPT-BACK AREA GENERAL 540 12 1 20 1 1 30 PANELBOARD 10 2,000 RCPT-UPS 38 SCHED & DTLS w 38 RCPT-TECH DESK 54012 20 1 1 20 12 1,080 RCPT-SHOW WINDOW 40 � o 41 RCPT-COPIER 1,200 12 20 1 1 20 SPARE 42 a o 43 EWH1 (MEN'S) 1,500 12 20 2 1 20 SPARE 44 45 1,500 1 20 i SPARE 46 O 47 EWH 1 (WOMEN'S) 1,500 12 20 2 1 20 SPARE 48 Drawn By. North �_ 1 49 1,500 1 20 SPARE 50 21 Of0 0 51 EWH2 (BREAK AREA) 2ce) ,050 10 25 2 1 20 SPARE 52 L� ecli N O_ 53 2,050 1 20 SPARE 54 � ��' ~ Short-Circuit and Voltage DropCalculations v1.03 55 EF-3 100 12 20 1 1 20 SPARE 56 �fl a I 57 FCU SMOKE DETECTORS 540 / 12 20 1 1 20 / SPARE 58 Dffieissued ie Distances aro for calculation purposes only and shall not be used for contractor takeoffs nor bidding - Contractor shall notify Engineer of any field condition that results in a change of 10% or greater circuit distance Client; !t2/24/2015 Lj 58 CU-1/CRU-1 1,352 12 15 2 1 20 / SPARE Landlord; w The following calculations aro based on the 'Point-by-Point' method where: 61 1,352 1 20 SPARE 52 63 HVAC RECEPT 180 12 20 1 1 20 SPARE 64 ermit: 4,/2015 65 SPARE / 20 1 1 20 SPARE 66 Bid: CD zo ISC (2) = ISC(1) x M(1) M= 1/(1+f) reede :(30) = 1.732 x L x in XFMR: f (30) =E(sca)x Vo x 1-73 x XZ IS(sca)= Vo x M x IPVOLTAGE DROP (30): 67 SPARE 20 1 1 20 SPARE 68 Constructions 1 ISC (1) = short circuit current at fault point 1 C x E 100,000 x KVA Vs XVD= ((R x cos(arccos(pf)) + X x sin (arccas(pf))) x L/f x I x 1.73) / E 69 SPARE 20 1 1 20 SPARE 70 Revision Issue. d = 71 SPARE / 20 1 1 20 SPARE 72 No. Date Description w � ISC (2) = short circuit current at fault point 2 Feederf (10)= 2 x L x Is XFMR: f (10)=�(s�lx Vp,�� VOLTAGE DROP (10): '0 73 SPARE 20 1 1 20 SPARE 74 3 C x E 100,000 x KVA XVD= ((R x aos(arcoos(pf)) + X x sin(arccos(pf))) x 2 x L/f x 1) / E 75 ISPARE 20 1 1 1 20 SPARE 76 77 SPARE 20 1 1 20 SPARE 78 L = Length of circuit E = Line to line volts IP = Primary short circuit current %VD CUM= Cumulative Voltage Drop from Fault Point 1 to Fault Point # 79 SPARE 20 1 1 20 SPARE 80 M C =" C" Factor from Bussman table where "C" = 1 / impedance per linear foot Vp = Primary voltage R= resistance in ohms per LF 81 SPARE 20 1 1 20 ISPARE I 82 cN Feeder Types = IS= Secondary short circuit current X= reactances in ohms per LF o, en 83 SPARE 20 1 1 ISPARE 84 NM - Non Magnetic Conduit, M - Magnetic Conduit, FB - Feeder Busway, PB - Plug-in Busway, TX - Transformer Vs= Secondary voltage N Mo SUBTOTAL 1 9,904 1 8,310 1 10,382 1 5,376 1 4,865 1 4,156 1 SUBTOTAL oLO Transformer FAULT VOLTAGE TOTAL Fault TOTAL PHASE A - VA 15,280 LOAD CONN. VA DF LOAD CONN. VA DF Fault Source Source Feeder L-L Circuit Load Circuit Conductor rn AMPS 127 COOLING 2,496 1.00 REFRIGERATION 1.00 r Point Bus/Feeder Phase (Fault Isc Conduit Material Conductor Busway Volts Length Power Load Resistance Reactance Arccos (pf) Degree CURRENT DROP V.D. Point TOTAL PHASE B - VA 13,175 HEATING 0 SIGN/DISPLAY 1,200 1.25 Z (F#) Description Point) (amps) Type/TX CU or AL # Wire/Bus Size 'C' value C value E L Factor(pf) A R X (Radians) Type kVA Rise Z V sec f M Isc %VD %VD CUM (F#) O AMPS 110 LIGHTING 3,037 1.25 KITCHEN 1.00 L-4y 1 Utilit Service Point 38230 Source Isc + 6X Motor Contribution = 38530 1 N i TOTAL PHASE C - VA 14,538 RECEPTACLES 15,840 1.0/.5 EXISTING 1.00 > Motor Contribution 50 The connected full load motor amps includes compressors) on the system N W 2 AMPS 121 MOTORS 308 1.00 LARGE MOTOR 1.25 TOTAL DEMAND 2 MSB 3 38530 NM CU 6 Sets of 300 kcmil 20868 480 200 0.9 1280 0.000044 0.000041 0.451027 0.222 0.82 31528 0.88% 0.88% N 3 TOTAL PNLBD - VA 42,993 SUPP HEAT 1.00 SHOW WINDOW 1.25 41,612 VA M I 3 H 1 3 2 31528 M CU 1 Set s) of 3/0 AWG 12844 480 150 0.9 160 0.000079 0.000052 0.451027 1.329 0.43 13539 0.81% 1.70% C) 4 AMPS 119 MISC EQUIP 20,112 1.00 LTG TRACK 480 1.00 116 A 10 4 TX-L1 Prim 3 3 13539 M CU 1 Sets of 4 AWG 3806 480 10 0.9 56 0.000310 0.000060 0.451027 0.128 0.89 11999 0.06% 1.76% (n 5 TX-L1 Sec 3 4 11999 TX 208 TP-1 45 150 5 208 4.803 0.17 2068 1.76% 5 PANELBOARD NOTES 56 L1 3 5 2068 M CU 1 Sets of 1/0 AWG 8925 208 10 0.9 160 0.000120 0.000055 0.451027 0.019 0.98 2029 0.18% 1.93% 6 GF - GFCI TYPE CIRCUIT BREAKER EM - EMERG LTG HANDLE-ON CLAMP SINGLE SECTION PANELBOARD N Q Drawing Number: = 0 7 FCU-1 3 3 13539 M CU 1 Sets of 10 AWG 981 480 60 0.85 21 0.001200 0.000063 0.554811 2.988 0.25 3395 0.48% 2.18% 7 R - VIA LTG RELAY PANEL N g it 8 FCU-2 1 3 3 1 13539 1 M CU 1 Sets of 10 AWG 1 981 480 70 1 0.85 21 0.001200 1 0.000063 0.554811 3.486 0.22 3018 0.56% 2.26% 8 LTG TRACK - TRACK LENGTH N 9 FCU-3 1 3 3 1 13539 1 M CU 1 Sets of 12 AWG 617 480 70 1 0.85 17 0.002000 1 0.000068 0.554811 5.543 0.15 2069 0.75% 2.44% 9 SIGN DISPLAY - SIGNAGE & DISPLAY CASE lE o (' Z a` Lq E3 X § " � U J 24 of 31 _ - - - - - - - - - - - CLOCK AUTOMATION SCENARIOS SCHEDULE RELAY PANEL SCHEDULE GLOBAL CONTROL OF CIRCUIT BREAKERS VERSION 1.0 VERSION 1.0 Channel Circuits Group Automation Data ELECTRICAL SYMBOLS THIS IS A MASTER LEGEND AND NOT ALL SYMBOLS, Panel Name: RP Description NOTE: ABBREVIATIONS, ETC. ARE NECESSARILY USED ON THE DRAWINGS. Location: Back Area Scenario Relay Load Load Load Channel C1 L1-12 Signage X Schedule ON/OFF Occupied Mon—Fri (time schedule per owner) ELECTRICAL ONE—LINE & RISER CIRCUITING & WIRING WIRING DEVICES & OUTLETS Controlled Type VA 1 2 3 4 516171819110 Manual ON/Schedule OFF Saturday (time schedule per owner) 1 1/2 GENERAL RETAIL SALES LED 848 X Astronomic ON/OFF Sunday (time schedule per owner) PANELBOARD MULTI—SECTION SWITCHED HOT CONDUCTORS (SHOWN TRAILING NEUTRAL) $ SINGLE POLE WALL SWITCH (NO LETTER DESIGNATION) 2 1/2 GENERAL RETAIL SALES LED 620 Ix I I Astro ON/Schedule OFF GRUSKIN (SEE SCHEDULES) PANELBOARD NEUTRAL CONDUCTOR 3 DISPLAY LED X C2 L1-2 Retail Sales Area X Schedule ON/OFF Occupied Mon—Fri (time schedule per owner) (SEE SCHEDULES) UNSWITCHED HOT CONDUCTORS (SHOWN LEADING NEUTRAL) SWITCH LETTER DESIGNATIONS AS FOLLOWS: 4 TRACK LED X 1/2 General Lighting X Security System ON/OFF Saturday (time schedule per owner) Tel Morris Avenue Springfield,NJ .89 81 2 = TWO POLE WALL SWITCH 5 RETAIL SALES RECEPTACLES X Manual ON/Schedule OFF Sunday (time schedule per owner) : 973.376.441 I Fax:973.376.8984 753 HOMERUN TO PANELBOARD, ARROWS INDICATE NUMBER 3 = THREE—WAY WALL SWITCH 6 SPARE Flick Warn 5 minutes — 2 hour Override www.GruskinGroup.com NJ REG 01009864-14 �ITX# TRANSFORMER - TX# SHIELDED OF CIRCUITS, HASH MARKS INDICATE NUMBER IR 4 = FOUR-WAY WALL SWITCH X Manual Dim Dimmin levels set b owner I �--- i P1 7 SPARE g 9 Y OR CONDUCTORS. INFORMATION AT ARROWS ARE CIRCUIT D = DIMMER TYPE SWITCH C3 L1-4 Retail Sales Area X Schedule ON OFF Occupied Mon-Fri time schedule per owner TYPE AND RATINGS i � TRANSFORMER P1-3,5,7 NUMBERS AND PANELBOARD. OS = OCCUPANCY SENSOR 8 FRONT SIGNAGE X / P ( P ) This document and the ideas and designs incorporated AS SHOWN TYPE AND RATINGS 9 SPARE 1/2 General Lighting X Security System ON/OFF Saturday (time schedule per owner) herein,as an Instrument of professional service, is the _ 1 i _ _i P = SPST PILOT LIGHT SWITCH AS SHOWN � 10 SPARE Manual ON/Schedule OFF Sunday (time schedule per owner) property of GRUSKIN ARCHITECTURE+DESIGN,P.C.,and\ EQUIPMENT GROUNDING CONDUCTOR IN CONDUIT K = KEYED LIGHT SWITCH GREEN INSULATION OR BARE M = MOTOR RATED SWITCH 11 SPARE Flick Warn 5 minutes — 2 hour Override wthout not to the writsed tenauteoration for any other project 800A SWITCH 225A CIRCUIT BREAKER ( ) X Manual Dimming Dimming levels set b owner without the E+DESIGN,P.authorization of GRUSKIN WP = WEATHER PROOF 12 SPARE g g Y ARCHITECTURE+DESIGN,P.C. 3P RATING AS SHOWN 3P RATINGS AS SHOWNDGROUNDING ONCONDUITCEILING 13 SPARE C4 L1-6,8 Retail Sales Area X Schedule ON/OFF Occupied Mon—Fri (time schedule per owner) AllRi@rtsReserved CI }� (GREENINSULATION WITHYELLOW TRACER) (��((❑U )}�j) ANDMOUNTED SOITH POWER SUPPLY LOADRELAY AS REQUIREDOR14 SPARE Display/Track Lighting Manual ON/Schedule OFF Saturday (time schedule per owner) ©2015GtuskinArchitecture+Design,P.C. 15 SPARE Merchandise Sunday (time schedule per owner) CONDUIT CONCEALED SIMPLEX RECEPTACLE — NEMA 5-20R, UNO 16 SPARE K�rr�ifh � � WA 200AS FUSED SWITCH � CS L1-14,16,18 Retail Sales Area X Schedule ON/OFF Occupied Mon—Fri (time schedule per owner) 3P RATING,POLES AND '� 20,22,24 Display Receptacles Manual ON Schedule OFF Saturday time schedule per owner AL 5421 MT 2537 / \ P Y P / Y ( P ) 200AF FUSE TYPE AS SHOWN _ _ _ CONDUIT IN/UNDER FLOOR/GROUND CONSTRUCTION DUPLEX RECEPTACLE — NEMA 5-20R, UNO AK 13167 NC 9961 FRS DOUBLE DUPLEX RECEPTACLE - NEMA 5-20R &NO ELAY PANEL SCHEDULE Merchandise Sunday (time schedule per owner) AR 3811 ND 1666 EXPOSED CONDUIT , UNO AZ 39209 NE A-3547 SCALE C6 Security X Additional Security On Receives input from security system CA C-29898 NH 2796 ® CIRCUIT IDENTIFICATION - SEE CIRCUIT SCHEDULE ^ 6 SPECIAL RECEPTACLE - NEMA TYPE AS NOTED �to turn ail building lighting ON upon alarm CO ARC-400347 NJ Al 09999 FLEXIBLE CONDUIT * = Master Control Buttons for manual and/or scheduled dimming of retail sales CT 9613 NM 004168 GFR GROUND FAULT RELAY -0 TWIST-LOCK TYPE RECEPTACLE DC ARC100723 NV 5521 uGFCI **= Security System ON/OFF iniation to provide override of scheduled on/off scenarios. DE 0006261 NY 025528-1 NY ST SHUNT TRIP LOW VOLTAGE CABLE (NOT ROUTED IN CONDUIT) 46 OR till GFCI TYPE RECEPTACLE* FL AR91629 OK a4895 UTILITYMETER CONDUIT METER (AS REQUIRED BY UTILITY) CONDUIT TURNING DOWN 6 ISOLATED GROUND TYPE RECEPTACLE* GA AR 11489 A011075 OH 13761 UTIL HI AOR - y# IA 05713 A RA5 -B 0 CONDUIT TURNING UP tW RECEPTACLE INSTALLED 6" ABOVE COUNTER OR BACKSPLASH* ID AR-984459 PR 19965 CURRENT TRANSFORMER RATING AS LIGHTING CONTROL SCHEDULE IL 001-019152 RI 2666 SPECIFIED OR REQUIRED RECEPTACLE INSTALLED IN CEILING* � IN AR10400066 SC 6834 CONNECTION POINT OR EQUIPMENT TERMINATION ® NO SCALE KS 4674 SD 11532 TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR RECEPTACLE INSTALLED IN FLOOR* KY 5967 TN 101374 -� EQUIPMENT TERMINATION LA 5734 TX 17680 RECEPTACLE INSTALLED VIA DROP CORD* ME ARC 2596 UT 5881358-0301 �It GROUND CONNECTION MD 11016 VT 2572 LIGHTING *DUPLEX RECEPTACLE SHOWN, SIMILAR FOR OTHERS MA 10635 VA 0401 011223 "11 GROUND ROD WP MI 1301052379 WA 10344 RECEPTACLE LETTER DESIGNATIONS AS FOLLOWS: MN 44326 WI 9900-005 CONTACT (OPEN OR CLOSED) A� FLUORESCENT LIGHT FIXTURE: (SEE LIGHT FIXTURE SCHEDULE) C = CLOCK HANGER TYPE MO A-2005029740 WV 3727 � E = EMERGENCY POWER LIGHTING CONTROL DEVICE SCHEDULE MS 3860 WY C-1967 S = SWITCHED HEATER 0 a = SWITCHED BY SWITCH "a" Pre(essialalseM: A = LIGHT FIXTURE TYPE "A" IG = ISOLATED GROUND OCCUPANCY SENSORS o TR = TAMPER RESISTANT ,Fp FAQF HP MOTOR SYMBOL MANUFACTURER EQUIVALENT COVERAGE �F F� ® WP = WEATHERPROOF MS C_ GINE TYPE MO ES MANUFACTURER DEVICE DESCRIPTION W X D ON MODE TIME DELAY VOLTAGE NOTES ## BLOCK LOAD KW OR KVA �' WR = WEATHER RESISTANT WATTSTOPPER COOPER WALL MOUNT DUAL TECHNOLOGY OCCUPANCY PIR MAJOR 30' x 35' MANUAL 15 MIN 120/277V 1 \ �• ® . . . MULTI—OUTLET SURFACE RACEWAY WITH NEMA 5-20R OS DW-100 HUBBELL SENSOR. SINGLE RELAY. INTEGRAL MANUAL PIR MINOR 15' x 20' r 17547PE y� FLUORESCENT LIGHT FIXTURE WITH NIGHT LIGHT RECEPTACLES 12" ON CENTER, UNO. LEVITON OVERRIDE SWITCH. LINE VOLTAGE. ULT MAJOR 20' x 20' SIGNALINGm V TELEPHONE OUTLET - FLOOR OR WALL MOUNTED. INSTALL 0 ULT MINOR 15' x 15' �o FLUORESCENT LIGHT FIXTURE WITH EMERGENCY LIGHTING AT SAME ELEVATION AS ADJACENT RECEPTACLE, UNO. L 0R7FRI N o, tl SIGNALING BELL 1 WATTSTOPPER COOPER CEILING MOUNT DUAL TECHNOLOGY OCCUPANCY PIR MAJOR 44' 0 AUTO 20 MIN 24V CF�'�-r�Vv BATTERY PACK ®0 DATA OUTLET — FLOOR OR WALL MOUNTED. INSTALL AT 5 DT-300 HUBBELL SENSOR. 360' COVERAGE. LOW VOLTAGE. PIR MINOR 25y�' 0 SIGNALING BUZZER FLUORESCENT LIGHT FIXTURE WITH DUAL BALLASTS CIRCUITED SAME ELEVATION AS ADJACENT RECEPTACLE, LINO. MASTER LEVITON ISOLATED RELAY. ULT MAJOR 40' x 40' LaN ° SEPARATELY. (SHADING IMPLIES EMERGENCY BALLAST WITH SWITCH ULT MINOR 30' x 30' / J 0 LV TRANSFORMER ® MULTI-SERVICE OUTLET - FLOOR OR WALL MOUNTED. INSTALL _XPIRES: 1 1/2 16 BATTERY PACK) AT SAME ELEVATION AS ADJACENT RECEPTACLE, UNO. ABBREVIATIONS A AUXILIARY DEVICES Ay LIGHTING TRACK WITH LIGHT FIXTURE TYPES AS INDICATED MULTI-SERVICE POWER POLE WITH TELEPHONE, DATA AND POWER SYMBOL MANUFACTURER EQUIVALENT A AMPERES, AIR (COMPRESSED) MAX MAXIMUM OUTLETS A = TYPE, SEE SCHEDULE IN SPECIFICATIONS TYPE MO SSERIES MANUFACTURER DEVICE DESCRIPTION VOLTAGE NOTES consultant Q uira A/C AIR CONDITIONING MCA MINIMUM CIRCUIT AMPACITY A LIGHT FIXTURE — CEILING / WALL MOUNTED. A GENERAL NOTES: WATTSTOPPER LC&D DIGITAL ROOM CONTROLLER SINGLE RELAY WITH 0-10V DIMMER 120/277V AF AMPERE FUSE MCB MAIN CIRCUIT BREAKER A = LIGHT FIXTURE TYPE "A" 0 MULTI-SERVICE FLOOR BOX WITH TELEPHONE, DATA AND POWER 1. ARRANGE SWITCHES AS INDICATED ABOVE. FIELD MODIFY O LMRC-211 LUTRON OUTLETS A = TYPE, SEE SCHEDULE IN SPECIFICATIONS LEVITON AFC ABOVE FINISHED CEILING MCC MOTOR CONTROL CENTER ARRANGEMENT TO COMPLY WITH SPACE LIMITATIONS AND CLEARANCE AFCI ARC FAULT CIRCUIT INTERRUPTER MD MOTORIZED DAMPER A WALL WASHER LIGHT FIXTURE - ARROW INDICATES DIRECTION. A POKE THROUGH, A = TYPE, SEE SCHEDULE IN SPECIFICATIONS REQUIREMENTS. W� HENDERSON SWITCHES ENGINEERS ®� Qo AFEA AREA FOR EVACUATION MDP MAIN DISTRIBUTION PANEL A = LIGHT FIXTURE TYPE "A" 2. PROVIDE FACTORY ENGRAVED FACE-PLATES AND LABELS WITH TEXT SYMBOL MANUFACTURER EQUIVALENT ASSISTANCE MFR MANUFACTURER ® THERMOSTAT AS INDICATED. TYPE MO SERIES MANUFACTURER DEVICE DESCRIPTION VOLTAGE NOTES rjyj AFF ABOVE FINISHED FLOOR MG MOTOR GENERATOR A WALL MOUNTED LIGHT FIXTURE. 8345 LENEM DRIVE,SURE 300 AFG ABOVE FINISHED GRADE MH MANHOLE EZI A = LIGHT FIXTURE TYPE "A" JUNCTION BOX OUTLET BOX 3. PROVIDE SWITCHES WITH INDICATOR LIGHTS. LENEXA,KS bb214 ® / LV DCC2 HUBBELL WHEN LOAD IS ONWATTSTOPPER COOPER LOW VOLTAGE MOMENTARY SWITCH FOR MANUAL ON/OFF CONTROL. INTEGRAL LED ILLUMINATED 24V 3. TEL 913 742 5000 FAx 913 742 5001 Al ANALOG INPUT MIN MINIMUM (� LEVITON AIC AMPERE INTERRUPTING CURRENT MLO MAIN LUGS ONLY Y SITE LIGHTING FIXTURE (SEE LIGHT FIXTURE SCHEDULE) JUNCTION BOX/OUTLET BOX 4. ALL MASTER SWITCHES TO SERVE AS MANUAL 2—HOUR OVERRIDE. www.hei-eng.com AL ALUMINUM MOCP MAXIMUM OVERCURRENT C EATON SCHNEIDER DIGITAL MULTI-BUTTON SWITCH FOR MANUAL ON/OFF/DIMMING AND SCENE CONTROL. INTEGRAL 24V 3 1550003152 AO ANALOG OUTPUT PROTECTION A EXIT SIGN — CEILING / WALL MOUNTED, ARROWS AS INDICATED. Q BLANK FACE GFCI FEED THROUGH DEVICE MASTER SWITCH KEYED NOTES: PRC-DS-# LED AT EACH BUTTON IS ILLUMINATED WHEN LOAD IS ON. "MS" INDICATES MASTER SWITCH; AP ACCESS PANEL MSB MAIN SWITCHBOARD ® A = LIGHT FIXTURE TYPE "A" (SEE LIGHT FIXTURE SCHEDULE) MS RE: 2/E4.0 SWITCH SCHEDULE FOR PROGRAMMING. SHALL BE FROM SAME MANUFACTURER G n ATS AUTOMATIC TRANSFER SWITCH MSWB MAIN SWITCHBOARD ESR EMERGENCY SHUNT RELAY ❑1 CONFIRM JUNCTION BOX SIZE FOR DIGITAL MASTER CONTROL SWITCH $ AS SWITCHING CONTROL PANEL. Job Name and Number. 2015-0131 AWG AMERICAN WIRE GAUGE MS/TP MASTER SLAVE/TOKEN PASSING A 4--pEMERGENCY BATTERY PACK LIGHT FIXTURE - CEILING/WALL WITH MANUFACTURER PRIOR TO ROUGH-IN. SEE BELOW FOR BUTTON BAS BUILDING AUTOMATION SYSTEM - COMMUNICATION TRUNK 004 L-1 MOUNTED. (SEE LIGHT FIXTURE SCHEDULE) PROGRAMMING. BFF BELOW FINISHED FLOOR MTD MOUNTED Proposed O DRIVER FOR LIGHT FIXTURE(S). POWER EQUIPMENT & DEVICES GENERAL NOTES: VERIZON BFG BELOW FINISHED GRADE N/A NOT APPLICABLE � � A OCCUPANCY SENSOR LAYOUT BASED ON WATTSTOPPER COVERAGE PATTERNS. ADJUST QUANTITIES AND LOCATIONS FOR EQUIVALENT BI BINARY INPUT N C NORMALLY CLOSED 5—Button Master Control Switch MS Schedule / STANDARD MOUNTING HEIGHTS ELECTRICAL SERVICE PANELBOARD Button Channels Controlled Label MANUFACTURERS LISTED BELOW PER MANUFACTURER—SPECIFIC SPACING CRITERIA. BKR BREAKER NIC NOT IN CONTRACT � = B MANUFACTURERS CONSIDERED EQUIVALENT FOR SUBMISSION ARE LISTED IN 'EQUIVALENT MANUFACTURER' COLUMN IN SCHEDULE. DURING SUBMITTALS, PROVIDE STORE BO BINARY OUTPUT NL NIGHT LIGHT (AFF, AFG, UNLESS NOTED OTHERWISE) (SURFACE OR FLUSH MOUNT) 1 1 1/2 GENERAL SALES PRODUCT CUTSHEETS AND SHOP DRAWINGS (AS FURTHER DEFINED IN GENERAL NOTES OF THIS SCHEDULE) FOR ENGINEER'S REVIEW. C CONDUIT N/O NORMALLY OPEN 2 2 1/2 GENERAL SALES C SHOP DRAWINGS FOR LIGHTING CONTROL DEVICES THAT ARE INTENDED FOR USE AS A LIGHTING CONTROL SYSTEM SHALL INCLUDE PROJECT SPECIFIC LIGHTING CD OC ON CENTER ELECTRICAL T�CANDELA OS OCCUPANCY SENSOR ALARMS 48 TERMINAL CABINET (SURFACE OR (LEER) o 3 3,4 DISPLAY/TRACK LTG CONTROL SCHEMATICS AND SCHEDULES. ALSO, AT ENGINEER'S REQUEST, PROVIDE A SCALED EQUIPMENT PLAN FOR REVIEW OF EQUIPMENT LOCATIONS CT CURRENT TRANSFORMER FLUSH MOUNT), TYPE AS NOTED 4 5 RETAIL RECEPTACLES WITHIN PROJECT SPACE CONSTRAINTS. CAN CABLE TELEVISION SYSTEM PDU POWER DISTRIBUTION UNITPLYWOOD TERMINAL BOARD FOR TELEPHONE 5 1-5 RETAIL ALL 'ON OFF' D OCCUPANCY SENSOR SHOP DRAWINGS SHALL INCLUDE LIGHTING PLANS SHOWING LOCATION, MOUNTING HEIGHT, ORIENTATION AND COVERAGE AREAS FOR EACH ANNUNCIATOR PANELS 48" o OCCUPANCY SENSOR. ALSO INCLUDE ON PLANS OTHER CEILING MOUNTED SYSTEMS, SHOWING COORDINATION WITH CEILING DEVICES INCLUDING BUT NOT CCN CLOSED CIRCUIT TELEVISION PH, � PHASE SYSTEM, UNO. SIZE AS NOTED. VERSION 1.0 CKT CIRCUIT PIV POST INDICATOR VALVE CLOCK OUTLETS (CENTERLINE) 84" LIMITED TO HVAC SUPPLY AND RETURN GRILLES, SPRINKLERS, AND LIGHT FIXTURES. CPT CONTROL POWER TRANSFORMER PNL PANEL CONTROLS (CENTERLINE) 48" ® ELECTRICAL DISTRIBUTION PANELBOARD E PROVIDE ALL OCCUPANCY SENSORS BY THE SAME MANUFACTURER. CU COPPER, CONDENSING UNIT LIGHTING CONTROL F VERIFY COLOR(S) FOR ALL WALL AND CEILING MOUNTED LIGHTING CONTROL DEVICES WITH THE ARCHITECT. PNLBD PANELBOARD EXIT SIGNS (WALL MOUNTED, BOTTOM) 80" G PROVIDE COPIES OF OPERATION INSTRUCTIONS FOR ALL DEVICES TO OWNER. Job Address CVD CUMULATIVE VOLTAGE DROP PROVIDE FURNISH AND INSTALL SWITCHBOARD OR MOTOR CONTROL INTERCOM AFEA ONLY 36" ® CENTER ON HOUSEKEEPING PAD H ALL WALL SWITCH AND CEILING SENSORS SHALL HAVE AN ADJUSTABLE TIME DELAY RANGE OF 0-30 MIN, UNO. DDC DIRECT DIGITAL CONTROL PT POTENTIAL TRANSFORMER ( ) 2 SWITCHBANK ELEVATION I DO NOT INSTALL LINE VOLTAGE SENSORS ON GFCI PROTECTED CIRCUITS. Washington Square Mall DI DIGITAL INPUT, DUCTILE IRON PTZ PAN, TILT, ZOOM INTERCOMS 48" NOT TO SCALE J LIGHTING CONTROLS PRICING SHALL BE COMPLETELY SEPARATE OF ANY LIGHT FIXTURE PRICING. ANY LIGHTING CONTROLS PRICING THAT IS 9585 S.W. Washington DN DOWN TRANSFORMER g QTY QUANTITY PANELS/PANELBOARDS (TOP) 72" SUBMITTED WITH LIGHT FIXTURE PRICING (UNIT OR MINI—LOT) WILL BE IMMEDIATELY REJECTED IN ITS ENTIRETY. Square Road DPDT DOUBLE—POLE, DOUBLE—THROW RCPT RECEPTACLE PHOTOCELLS 144" `0• MOTOR K INSTALL WALL BOX DIMMERS TO ACHIEVE FULL RATING SPECIFIED AND INDICATED AFTER DE—RATING FOR GANGING AS INSTRUCTED BY MANUFACTURER. Portland, Lland OR 97223 DPST DOUBLE—POLE, SINGLE—THROW RLA RUNNING LOAD AMPS L CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING COMPATIBILITY OF ALL LIGHTING CONTROL DEVICES IN THIS SCHEDULE THAT ARE INTENDED TO OPERATE TOGETHER. f Q EM EMERGENCY RTU ROOFTOP UNIT RECEPTACLES (CENTERLINE) 16" DISCONNECT SWITCH - "200/3/150" DENOTES M PROVIDE A NEUTRAL CONDUCTOR TO ALL WALL BOX DIMMERS. DO NOT SHARE NEUTRAL CONDUCTOR ON LOAD SIDE OF DIMMER. SnaCe RO5-ROT EPO EMERGENCY POWER OFF 200/3/150 M w SD SMOKE DETECTOR, SUPPLY DUCT RECEPTACLES (EXTERIOR) 24" rp AMPERES/POLE/FUSE NF= NON-FUSED CB= CIRCUIT C14ETR EXISTING TO REMAIN SF SQUARE FEET, SUPPLY FAN RECEPTACLES GARAGES 26" BREAKER (200/3/CB) SCHEDULED NOTES: M FACP FIRE ALARM CONTROL PANEL SPDT SINGLE—POLE, DOUBLE—THROW (GARAGES) 1. REQUIRES A NEUTRAL CONDUCTOR FOR OPERATION. DrawirTttk: 0 RECEPTACLES IN EQUIPMENT ROOMS 48" 2. FOR SELECTED DAYLIGHT SENSOR, CONFIRM FINAL LOCATION AND INSTALLATION PER MANUFACTURER'S RECOMMENDATIONS. INCLUDE MANUFACTURER'S ELECTRICAL 0 FBO FURNISHED BY OTHERS/OWNER SPST SINGLE—POLE, SINGLE—THROW COMBINATION DISCONNECT (SAFETY) SWITCH AND r_ 0 FCA FAULT CURRENT AMPS SS STAINLESS STEEL, SANITARY REMOTE INDICATING LIGHT (EQUIPMENT ROOMS) 48" 30/3/15/1 MOTOR STARTER "30/3/15/1" DENOTES LIGHTING CONTROL DIAGRAM GENERAL NOTES: RECOMMENDED LOCATION WITH SUBMITTALS FOR REVIEW. Ill 3. MOMENTARY SWITCH SHALL BE COMPATIBLE WITH ITS CONNECTED LIGHTING CONTROL DEVICE (I.E. OCCUPANCY SENSOR, RELAY PANEL, ETC.) FF FINISHED FLOOR SEWER, SOIL STACK L® AMPERES/POLE/FUSE/NEMA STARTER SIZE NF= REMOTE INDICATING LIGHT FINISHED AREAS CEILING LEGEND DTLS M / ( ) 1. LIGHTING CONTROL DIAGRAM IS DIAGRAMMATIC AND REPRESENTS THE 4• LIGHT LEVEL SETPOINT REPRESENTS AVERAGE MEASURED VALUE AT HORIZONTAL TASK PLANE WITHIN DAYLIT ZONE AND DOES NOT NECESSARILY REFLECT VALUE } } ca w FLA FULL LOAD AMPS ST SHUNT TRIP, STEAM TRAP NON-FUSED CB= CIRCUIT BREAKER (30/3/CB/1) �i SCHED a t j FLR FLOOR SWBD SWITCHBOARD SAFETY SWITCHES 48" GENERAL SCOPE OF WORK AND THE LOCATION OF DEVICES IN MEASURED AT THE SENSOR ITSELF. DURING STARTUP, COMMISSION DAYLIGHT SENSOR AND LIGHTING CONTROLLER TO ADJUST LIGHTS ON/OFF AND RAISE/LOWER TO / STARTERS 48" MAGNETIC MOTOR STARTER, NEMA RELATION TO EACH OTHER ALONG THE POWER CIRCUIT. ELECTRICAL SATISFY INDICATED SETPOINT. VERSION:2.4 a 00 FVNR FULL—VOLTAGE, NON—REVERSING TL TWISTLOCK ®2 SIZE AS NOTED. 3-POLE, UNO. CONTRACTOR SHALL COORDINATE WITH SELECTED MANUFACTURER. v j GC GENERAL CONTRACTOR TR TAMPER RESISTANT SWITCHES (CENTERLINE) 44" PROVIDE ALL PARTS AND PIECES REQUIRED FOR A FULLY Q; o GFCI GROUND FAULT CIRCUIT TX TRANSFORMER TELEPHONES (PUBLIC) 1 ® 48", 1 ® 36" MS MANUAL STARTER FUNCTIONAL SYSTEM. INTERRUPTER TYP TYPICAL 'n I GFR GROUND FAULT RELAY TELEPHONE, DATA OUTLETS (CENTERLINE) 16 VFD VARIABLE FREQUENCY DRIVE 2. LIGHTING CONTROL SYSTEM INCLUDING, BUT NOT LIMITED TO Drawn Ry: North C) o U/F UNDERFLOOR INTEGRAL TIME CLOCK, RELAYS, AND DIGITAL LIGHTING CONTROL �� N Q G GROUND U/G UNDERGROUND TELEPHONE TERMINAL BOARD (BOTTOM) 6" R RELAY OR CONTACTOR (IN SCHEMATICS) SWITCHES. PROVIDE SHOP DRAWINGS FOR APPROVAL PRIOR TO � *��^ N GND GROUND UH UNIT HEATER TELEVISION OUTLETS 16" O PURCHASE. AJO GRS GALVANIZED RIGID STEEL MAGNETIC CONTACTOR, SIZE, COIL VOLTAGE AND Die Issued For o I U/S UNDERSLAB © HOA HAND-OFF-AUTOMATIC NUMBER OF POLES AS INDICATED L= LIGHTING 3. INTEGRAL TIME CLOCK SHALL BE ASTRONOMIC AND PROGRAMMABLE Client i2/24/2015 a UL UNDERWRITERS LABORATORIES, L aIG ISOLATED GROUND INC. CONTACTOR, P= POWER CONTACTOR) WITH 365 DAY AND HOLIDAY SCHEDULING AND 24 HOUR BATTERY Landlord; J2/24/2015 lsc SHORT CIRCUIT CURRENT ANNOTATION BACK-UP. RELAYS SHALL BE MECHANICALLY HELD, SINGLE POLE, N UNO UNLESS NOTED OTHERWISE 20A RATED, NORMALLY CLOSED CONTACTS. LIGHTING CONTROL PANELBOARD Permit�2/2412015 to JB JUNCTION BOX TS TIME SWITCH r UPS UNINTERRUPTIBLE POWER SUPPLY SYSTEM SHALL COMPLY WITH ALL LOCAL AND STATE ENERGY CODES. r--__------- ------ Bid: o Z J-Box JUNCTION BOX ❑1 ELECTRICAL PLAN NOTE CALLOUT C, kcmil 1000 CIRCULAR MILS V VOLT(S) PC PHOTOCELL I Constructions VAC VOLTS ALTERNATING CURRENT 4. CIRCUITING SHOWN ON THE PLAN CORRESPONDS TO THE LIGHTING I 1 TECHNOLOGY PLAN CALLOUT 0-10V DIMMABLE RevlsionIssue. Z KK KIRK KEY CONTROL SCHEME. IF CIRCUITING IS CHANGED IN THE FIELD, l = VD VOLTAGE DROP INDICATING LIGHT I LIGHT FIXTURES Na. we DesalptIon w kV KILOVOLT EQUIPMENT DESIGNATION (OWNER FURNISHED, ENSURE THAT SYSTEM PROGRAMMING WITH REVISED CIRCUITING DEDICATED CIRCUIT FOR I vDc VOLTS DIRECT CURRENT CONTRACTOR INSTALLED) F0 PUSH BUTTON 3 kVA KILOVOLT-AMPS • MEETS THE ORIGINAL LIGHTING CONTROL SCHEME. UPDATE RELAY RELAY PANEL POWER I kVAR KILOVOLT—AMPS REACTIVE VFD VARIABLE FREQUENCY DRIVE PANEL SCHEDULES IN RECORD DRAWINGS. I NON—TRACK kW KILOWATT W WIRE CONNECTION POINT OF NEW WORK TO EXISTING • STOP—START PUSH BUTTON CONTROL STATION I so LIGHT FIXTURES WP WEATHERPROOF 5. COORDINATE WITH OWNER AND LANDLORD FOR PROGRAMMABLE TIME BRANCH CIRCUITS PER m kWH KILOWATT-HOUR DETAIL REFERENCE UPPER NUMBER INDICATES DETAIL NUMBER CLOCK SCHEDULES. PROVIDE THE GENERAL CONTRACTOR WITH POWER RELAY PANEL SCHEDULES i= XP EXPLOSION-PROOF •'• HAND-OFF-AUTO PUSH BUTTON CONTROL STATION rN LF LINEAR FEET M1 LOWER NUMBER INDICATES SHEET NUMBER OPERATIONS MANUAL AFTER JOB IS COMPLETE. A COPY OF THE PANEL PANEL (TYPICAL U.N.O.) MAN MASTER ANTENNA TELEVISION aD MUSHROOM-TYPE PUSH BUTTON RECORD DRAWINGS AND RELAY SCHEDULE WITH ANY FIELD CONDITION 'L1' 'RP' TRACK uCi 0 SYSTEM CHANGES IDENTIFIED SHALL BE LEFT IN THE DOOR OF THE PANEL. LIGHT FIXTURES o M1 SECTION CUT DESIGNATION ( ) ,LO � }{`v OVERHEAD PADDLE FAN CL ON TRACK Z LIGHTING CONTROL DIAGRAM KEYED NOTES: ❑1 ca N STAND-ALONE LIGHTING CONTROL RELAY PANEL INFORMATION: J, 2 LOW VOLTAGE CABLING > a. MANUFACTURERS: LUTRON, WATTSTOPPER, LEVITON, LC&D, GREENGATE �3I MANUFACTURER'S / b. ENCLOSURE: SURFACE MOUNT, NEMA 1 REQUIREMENTS (TYPICAL) o 1 c. INTEGRAL TIME CLOCK: REFER TO CASS AND RELAY PANEL SCHEDULES ON _[PER TO ADDITIONAL N j THIS SHEET FOR TIME CLOCK AND RELAY PROGRAMMING. DIGITAL SWITCHES ❑2 DIGITAL LIGHTING CONTROL SWITCH. EMERGENCY FIXTURES WITH DrawingNumber: N z X PROVIDE ALARM INPUT FROM SECURITY. COORDINATE ALL REQUIREMENTS WITH BATTERY PACKS N � j SECURITY CONTRACTOR. dLIGHTING CONTROL DIAGRAM 2 0 ;Z E4 .- �-c �j (:T NOT TO SCALE coU , 25 OF 31 OWNER/TENANT: I. THIS PROJECT SHALL COMPLY WITH ALL ACCESSIBILITY GUIDELINES AND LOCAL ACCESS CODE REQUIREMENTS. 2. THRESHOLDS SHALL BE NO HIGHER THAN 1/2" ABOVE THE FLOOR EDGE TO BE BEVELED 1/8" HAT CHANNEL FRAMING O 24" O.G. MAX.AND NOT MORE 0" O.C. EACH WAY AND - WITH A SLOPE NO GREATER THAN I IN 2. THAN 6" FROM WALL AT CHANNEL SPLICES OVERLAP 12" AND WITHIN 6'-0"16 GA. WIRE 12''- EACH WALL SECURE WITH DOUBLE STRAND 16 GA. TIE WIRE. � O D I �� 3. DOOR HARDWARE SHALL BE OF THE LEVER OR PUSH TYPE, MOUNTED 30" TO 44" ABOVE HANGING WIRE SECURE THE FLOOR AND BE OPERABLE WITH A MAXIMUM EFFORT OF 5 LBS. FOR INTERIOR DOORS. FROM MAIN RUNNERS TO Chocolatier EXTERIOR DOOR - 81/2" POUNDS MAX. PRESSURE FIRE DOOR - 15 POUNDS MAX. HANGING WIRE TO STRUCTURE STRUCTURE ABOVE - 12 GA. GODIVA CHOCOLATIER, INC. PRESSURE. ABOVE AT 48"O.C. MAX. - PROVIDE NOTE: ALL SPLAY WIRES MIN. WIRE a 48" MAX. O.G. W/ 333 WEST 34TH STREET ADDITIONAL WIRE SUPPORT AT ALL SHALL BE TAUT 4 TIED a 4 MIN. TIGHT TURNS ON EACH NEW YORK, NY 10001 4. ACCESSIBLE DOORS MUST BE MINIMUM V-0"W X 6'-8"H. MODIFY IF REQUIRED. LIGHT FIXTURES S W/ MIN. OF END (TYP.) - (UNLESS 3 TURNS IN 1" OF RUN OTHERWISE NOTED PER MFR PROJECT PLANNER: 5. PROVIDE 18" CLEAR SPACE AT STRIKE/PULL SIDE ON INTERIOR DOORS, AND 12" CLEAR 45'MAX INSTALLATION AT STRIKE/PUSH SIDE OF DOORS W/ CLOSERS AND 24" CLEAR AT STRIKE/PULL SIDE ON INSTRUCTIONS.) EXTERIOR DOOR SECURE SUPPORT WIRES TO STRUCTURAL STEEL CROSS TEE 6. FLOOR SHALL BE LEVEL THROUGHOUT. �i� 45.*MAX MEMBERS ABOVE - NOT 45'MAX TO ROOF DECK NOTE: % 1. CONTRACTOR SHALL VERIFY WITH SUPPLIER THAT ALL HARDWARE MEETS ADAAG = ALL 2' X 2' CEILING LIGHT FIXTURES I I/2 CHANNEL AT 48 O.G. max. - REQUIREMENTS. PROVIDE ADDITIONAL BRACING A7 AND HVAC AIR BE SUPPORTED BYIA MINIMUM Or- 5 F ",-;- SHALL ALL POINT LOADS WITHIN CEILING TWO (2) HANGERS AT OPPOSITE 8. ALL DOOR HINGES TO BE STEEL BALL BEARING, FULL MORTISE TYPE, AS PER AS REQ'D 1 5/8" x 16 GA. METAL JOIST FRAMING m 48" O.C. SPECIFICATIONS. 1A CORNERS. UNLESS OTHERWISE (4)-12 GA. SPLAY WIRES - SPLAYED 90' FROM EACH NOTED PER MFR INSTALLATION 5/8" TYPE 'X' G.W$. ON MTL. STUDS - WJCA INC. S. ALL METAL DOOR FRAMES TO BE PROVIDED WITH SILENCERS. TYPICAL CEILING CONSTRUCTION OPTIONS: OTHER AND 45' (MAX.) FROM CEILING PLANE INSTRUCTIONS. STUDS SPACED/SIZED ACCORDING 763 SUSQUEHANNA AVE. Tie cartRaeTOR we ne omwTo error ones ueo sTa"oaw nwuneETRwerarawmmnemcwoeraLuia' coReiw�crnn 70 CEILING CONDITIONS WHERE aaw eDorta cwanv,�.�aR auUD e[iee'oraleLe roe ne 1/8" HAT CHANNEL FRAMING FRANKLIN LAKES, NJ 07417 24" O.C. MAX.AND TEL: 201-848-9060 10. ALL INTERIOR DOORS 70 BE PROVIDED WITH COMMERCIAL GRADE WALL OR FLOOR WILMbYe�rort�sarwJFrv»ow�waoMOT ma ne DESIGN DEFLECTION SHALL NOT STOPS. .aoarecTooRiEwv+re�Heyorx+*xiE*+erenwTwseremm NOT MORE THAN Co" FROM WALL AT CHANNEL n meronenleelaa EXCEED L/240 - REFER TO MFG'S SPLICES OVERLAP 12" AND SECURE WITH DOUBLEFAX: 201-848-9881 II. GENERAL CONTRACTOR SHALL ENSURE ALL EXISTING DOORS TO REMAIN TO BE IN GOOD SIZING TABLES STRAND 16 GA. TIE WIRE. MAIN RUNNER OPERATING ORDER AND TO MEET ALL LOCAL BUILDING CODES AND ADAAG ARCHITECT: REQUIREMENTS. GENERAL CONTRACTOR TO RESTORE DOORS AND HARDWARE TO "LIKE NEW" CONDITION. G.C. TO PROVIDE NEW HARDWARE. 12. EXTERIOR HINGES TO HAVE NON-REMOVEABLE PINS. O TYP. G .W. B. CELING NOT TO SCALE TTYP. G .W. B. CELING NOT TO SCALE rj TYP, A.C.T. CELING NOT TO SCALE DAVID A. UDKOW 13. ALL RATED DOORS TO BE SUPPLIED WITH THRESHOLDS AND SMOKE SEAL PER DOOR FRAME DETAIL HARDWARE REMARKS 11881 NORTH 113TH WAY SPECIFICATIONS AND CODE. a--r 14. COORDINATE EXTERIOR DOOR DETAILS AND THRESHOLDS WITH LANDLORD. DOO LOCATION SIZE TYPE MAT'L FINISH MAT'L FINISH HEAD JAMB SILL CaROUP SCOTTSDALE, AZ 85259 ENTRY DOOR (2) 31-0 Ilui x V-0"H F - PREFIN. N/A N/A 2O NON-SALES 3'-0"U! x -I'-0"H x 13/4"D A S.C. PAINT WOOD PAINT 2/A301 I/A301 - 3 X 3 TOILET ROOM 3'-011UJ X 6'-S"H X 13/4"D B S.C. PAINT H.M. PAINT 2/A301 1/4301 - 5 O 4 REMOTE STORACaE 3'-0V x 1'-0"H C HM. PAINT HM. PAINT - - - 1 �V` V> LIC. #: 2182 O EXP. DATE: 6/30/16 DOOR NOTES DOOR SCHEDULE G O D I VA :3 Chocolatier PULL SIDE x PUSH SIDE NO. HARDWARE GROUP NO. HARDWARE GROUP NO. HARDWARE GROUP NO. HARDWARE GROUP STORE NO: �3a�" — FRAME: HOLLOW METAL KD 524 (z E FRAME: EXISTING 1 n 2 3 4 PROJECT LOCATION: - a s w LEVER SET: 5CHLAGE ALW15P-SAT-626 STOREROOM LOCK,2 3/4' BACKSET, n LEVER SET: 5CHLAGE ALI05-JUP-613 PASSAGE LATCH,2 3/4 BACKSET, II-II6 II-096 SPRING LATCH,10-001 STRIKE (PREPARED FOR "BEST' u0 SPRING LATCH,10-025 STRIKE CORE) m a HINGES: MCKINNEY 4 1/2' X 4 1/2" 1522-HT-USI05 STANDARD WEIGHT SPRING WASHINGTON SQ. MALL X=11.8 IN. (300MM) ? HINGES: MCKINNEY 41/2' X 41/2" T2114-NRP-US26D, 11/2 SET HINGE SET SPACE B04 0)'^ IF THE DOOR HAS BOTHP ? 9585 SW WASHINGTON uJ A CLOSER AND A LATCH CL05ER: NORTON 1500 PARALLEL ARM PUSH SIDE-INTERIOR MOUNT umu} STOP: WALL BUMPER U5108 FINISH SQUARE ROAD N N SILENCERS: 3 NEOPRENE PORTLAND, OR 90703 '^ FRONT APPROACHES - SWINGING DOORS STOP: WALL BUMPER U526D FINISH J PULL SIDE PUSHSIDESILENCERS: 3 NEOPRENE SEAL: PEMKO PK33W HEAD 4 JAMBS ^0 a` in aim� SEAL: PEMKO 303APK HEAD 4 JAMBS BOTTOM: PEMKO 3155N (ON STOCKROOM SIDE) ' V MI ISSUE DATE: X y y E I I♦ THRESHOLD: PErlco 20054? KIGCPLATE: (U BRONZE 24" X36" NO. DATE DESCRIPTION _ ^ CLOSER" NORTON 8000 SERIES WITH HOLD OPEN 12-11-15 ISSUED FOR DID, PERMIT AND LANDLORD REVIEW X=36 IN.(915MM) MIN. Y=48 INA220MM) MIN. NO. HARDWARE GROUP NO. HARDWARE GROUP NO. HARDWARE GROUP NO. HARDWARE GROUP Q IF Y=60 IN.(1525MM): IF DOOR HAS BOTH A X=42 IN.(1065MMMINIMUM LATCH AND A CLOSER IF Y=54 IN. (13101"IM) 2 - SETS 12"ODOOR FULLS 8 co HINGE-SIDE APPROACHES - SWINGING DOORS 5 DOOR: WOOD SOLID GORE 6 � .C. 1 n ALL DOORS IN ALCOVES SHALL COMPLY FRAME: HOLLOW METAL KD ~ PIVOT: I - SET TOP OFFSET PIVOT WITH CLEARANCES FOR FRONT APPROACHES. O LEVER SET: SCHLAGE AL405-JUP-613 PRIVACY LATCH, CLOSER: I - DORMA RTS W FLOOR CLOSER WITH OFFSET ARM PULL SIDE w 2 3/4" BACKSET, II-II6 SPRINGLATGH, 10-025 p U PUSH SIDE o STRIKE N STRIKE: 2 - DUST PROOF STRIKE rn � vJ F '60 �m HINGES: MCKINNEY 4 1/2" X 4 1/2" 1522-HT-US10B TOP: I - 4' CRL SQUARE TOP DOOR RAIL X FULL WIDTH - BRONZE ANO. y Ee I ♦ X I ♦ ♦yn X I STANDARD WEIGHT SPRING HINGE SET BOTTOM: I - b" CRL SQUARE BOTTOM DOOR RAIL X FULL WIDTH - BRONZE ANO. 11 STOP: WALL BUMPER U5105 FINISH LOCK: 2 - BOTTOM RAIL LOCK 4= p SILENCERS: 3 NEOPRENE CYLINDER I - EXTERIOR CYLINDER(CONSTRUCTION CYLINDER) ?NUMB TURN: I - ?NUMB TURN - BRONZE ANO. Y=54 IN.0310MM) MIN. Y=48 IN.(1220MM) MIN. IF DOOR HAS A CLOSER IF DOOR HAS A CLOSER FLOOR STOP: I - SET AT W DEGREE OPEN LATCH-SIDE APPROACHES - SWINGING DOORS co 19 4 DOOR CLEARANCES HARDWARE SCHEDULE ; T NOT TO SCALE �=� DAVID A. UDKOW T C" 2182 = • SCOTTSDALE, AZ REFER TO 6, m„ PARTITION TYPES O 2 2 DOOR - AS SCHEDULED 43 2" HOLLOW MTL. FRAME - JAMB 4301 01 ii ' " " " ii DOOR TYPE A DOOR TYPE B DOOR TYPE C / � DRAWING TITLE: OD SOLID CORE WOOD DOOR, SOLID CORE WOOD DOOR, SALES / NON SALES DOOR (TOILET ROOM DOOR) p_3 / ONE WAY / \ O CONSTRUCTION T / VIEWER / 9 REFER TO NOTE "E" W F W DETAILS \J 1 IL OF THE DOOR NOTES. 0 q / - � CLi_- O O 4301 A501 9 EXIT DEVICE \ OF / =0 PULLS F y a " DOUBLE 3 5/8" BRONZE \� - SALES SIDEDE OF OF DOOR METAL STUDS 2 OR \ ` \/ / DOUBLE 3 5/8" PROVIDE ANCHORS PROJECT NO: m WHEN SWING IS INTO n m STOCK ROOM METAL STUDS THREE (3) PER JAMB \. \ HOLLOW MTL. FRAME / HEAD STIFFENER SCREWS 154129 Q NII 1� E\ I . DOOR - AS SCHEDULED AT 24" O.G. DRAWING NO: Q DOOR TYPE "A" DOOR TYPE "B" DOOR TYPE "C" DOOR TYPE "F" A301 Q 3 DOOR TYPES SCALE: NTS 2 HEAD DETAIL SCALE: 3" = V-0" 10JAMB DETAIL SCALE: 3" = l'-0" d I UNE OF SUSPENDED CEILING NE OF SUSPENDED CEILING LINE OF SUSPENDED LINE OF SUSPENDED LINE OF SUSPENDED CEILING LINE OF SUSPENDED r. CEILING CEILING RUN 1' DAT ;'ra ';io CEILING UN 1' DATA CONDUIT CONDUIT UP TO 6' OUTLINE OF INTERACTIVE UP TO 6' ABOVE CEILING. ABOVE CEILING. DISPLAY WALL UN 1' DATA CONDUIT , OUTLINE OF VERIZON UN 1' DATA CONDUIT UN 1' DATA CONDUIT SEE TYPICAL DATA PULL SEE TYPICAL DATA , ; UP TO 6" ABOVE CEILING. • PULL STRING (2) -M-07 STRIP LIGHTS AT UPPER SEE TYPICAL DATA PULL r--------------- BRAND WALL FOCAL PANEL UP TO 6' ABOVE CEILING. UP TO 6 ABOVE CEILING. , STRING DETAIL CABINET, DAISY CHAINED TOGETHER WiTH STRING DETAIL I SEE TYPICAL DATA PULL r SEE TYPICAL DATA PULL OUTLINE OF VERIZON DETAIL I _____--L__-- (1) PLUG CORD TO BE PLUGGED INTO A � OUTLINE OF 42' LCD GRUSKIN ! STRING DETAIL STRING DETAIL SERVICE PRESENTATION t MULTi-OUTLET STRIP MONITOR (SB) I I I PANG PROVIDE TWO DEDICATED CIRCUITS, (1) I I I UNSWITCHED POWER OUTLET FIXTURE & I LINE OF BILL o ---- ----- OUTIJNE OF MONITOR I I FOR FIXTURE OUTLETS FIXTURE & , SWITCHED AND (1) UN%MHED, FOR z Imo, 294 Morris Avenue Springfield.N) o7oh31 I I PAYMENT KIOSK OSS UNSWTTCHED POWER OUTLET r o I WALL MOUNTED BRACKET Tel: 973.376.4411 Fax:973.376.8989 I i FOR FIXTURE 'INTERACTIVE DISPLAY WALL FIXTURE. � I ____r- - _ _._a I www.GruskinGroup.com NJ REG 0100.9869-14 ROUTE SWITCHED CIRCUIT THROUGH I S I = DATA BY VERIZON WIRELESS 1' DATA CONDUIT TO OUTLINE OF ACCESS , CONTACTOR 'Cl' AND CONTROL VIA j I SEE WALL MOUNTING This document and the ideas and designs incorporated 04 ELECTRICAL J-BOX 6' ABOVE SUSPENDED OPENING ON BACK PANEL MULTI-OUTLET EMS. `-- --+-- BRACKET 'B' FOR DETAIL herein,as an Instrument of professional service, Is the FLUSHED WiTH WALL FINISH t CEILING. �' 10 I property of GRUSKIN ARCH RECiURE+DESIGN,P.C.,and I WiTH BLANK COVER BY EC. , OUTLINE OF MY VERIZON ' L SEE WALL MOUNTING PLUGGED INTO THE FIXTURE & ATA BY VERIZON WIRELESS TA BY VERIZON WIRELESS is not to be used in whale or in part for any other project WIRELESS EXPRESS & BRACKET B FOR DETAIL SWITCHED CIRCUIT c I without the written authorization of GRUSKIN I OUTLETS HOPELINE FIXTURE TA BY VERIZON WIRELESS DUPLEX RECEPTACLE OUTLETS I SEE WALL MOUNTING MONITOR & UNSWITCHED POWER OUTLET ARCHITECTURE+DESIGN,P.C. All Rights Reserved PROVIDE POWER FEED THROUGH ; , TA BY VERIZON WIRELESS BRACKET 'C' FOR DETAIL c OUTLETS FOR RIC SEE WALL MOUNTING I— ©2015 Gruskin Architecture+Design,P.C. I J-BOX & I J-BOX FOR FOCAL WALL LIGHT , , I � BRACKET 'D FOR DETAIL I OUTLINE OF INTERACTIVE ul, FOCAL WALL I BOX. ROUTE SWITCHED o OUTLINE OF I `� Kith A. GmuM AIA L____ __________J CIRCUIT THROUGH CONTACTOR EQ. EQ SEE WALL MOUNTING "' LINE OF FINISHED DISPLAY WALL NE OF FINISHED 'Cl' AND CONTROL VIA EMS. UTI OF ACCESS • FLOR ACCESS OPENING NE OF FINISHED FLOOR v OPENING ON BACK PANEL BRACKET 'B FOR DETAIL ON BACK PANEL Ln N FLOOR AL 131 MT 2537 LINE OF FINISHED AAR K 3 11 NC 9961 LINE OF FINISHED FLOOR I-- F FLOORZPROVIDE 1 DATA F PROVIDE 1 DATA FEED PROVIDE 1) DATA F® AZ 39209 NE A6 3547 CA C-29898 NH 2796 PROVIDE 1 DATA I CO ARC-400347 NJ AI 09999 PROVIDE 1 DATA FEED CT 9613 NM 004168 DC ARC1007W 5521 17� 1/2' DE 00626123 NY 025528-1 NY FL AR91629 OK a4895 VERIZON BRAND WALL MY VERIZON WIRELESS EXPRESS BILL PAYMENT VERIZON SERVICE PRESENTATION INTERACTIVE DISPLAY SMART BOARD GA RA011075 off 13761 HI AR 11489 1 OR 4899 &NOT 0D2 E3S GR 4 PO R DI G 5 DI 6 L 0 IA 05713 -015432-B TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE ID AR-984459 PR 19965 IL 001-019152 RI 2666 IN AR10400066 SC 6834 KS 4674 SD 11532 KY 5967 TN 101374 LINE OF SUSPENDED CEILING LA 5734 TX 17680 MUD PLATE ME ARC 2.596 UT 5881358-0301 UN 1' DATA CONDUIT UP MD 11016 VT 2572 MA 10635 TO 6" ABOVE CEILING. SEE Ts• MI 130 052379 WA 10344 011223 TYPICAL. DATA PULL STRING MN 44326 W1 9900-005 1 DETAIL MO A-2005029740 3727 p O' ° MS 3860 WY C-1967 OUTLINE OF HOME °30 1,40` ' ., Fol ° Prafesslonal Seal: SOLUTION WALL PANEL PROVIDE TWO DEDICATED TRACK CIRCUITS, (1) SWITCHED AND4 - 24-30 2'_6• L CONTINUOUS PLUGMOLD WITH BUSHING POWER DATA ���NGIN EF so 1 , ErJ PhO;:�. (1) UNSWITCHED. ROUTE OUTLETS AT 6 Q.C. WIREMOLD 2000 ` 17547PE an no BOTTOM OF 10'-O' � BOTTOM OF 10'-0' PULL STRING SWITCHED CIRCUIT THROUGH SERIES IG20GB606 (L-2 FINISH), OR 4' CONDUIT SEE PLANS FOR � FIXTURE & I CONTACTOR 'Cl' AND I�� I SUSP. CEILING SUSP. CEILING BUSHING f MOUNTING RACKET B APPROVED EQUAL (LENGTH AS SIZE AND LOCATION. OUTS FOR FIXTURES: SX-21, CONTROL VIA EMS. � ��� � � �' i C3' REQUIRED) BOTTOM OF SEE PLAN OUTLINE OF ACCESS i �� T-05 TRACK /--COUNTER AND CABINETRY, TYP. SUSPENDED CEILING N BILL PAYMENT KIOSK Z0L OREG N �a°j OPENING ON BACK PANEL t I ADJUSTABLE LED ACCENT i T-07 HEAD C=91' LIGHi FIXTURE 'CR' MUD PLATE Mt , SEE WALL MOUNTING I f RECESSED IN CEILING, PLACE i SWITCHED MUD PLATE ' ANN >�C BRACKET 'C' FOR DETAIL i 24 " TO 30' FROM THE i RED - CR5362R 16' ts' DATA BY VERIZON WIRELESS t I CONDUIT AS REQUIRED o BOTTOM OF SEE PLAN I I f FACE OF THE GRAPHICS f SUSPENDED CEILING EXPIRES: 1 31/20 N I (TYP-) I 1 PANEL I ° ° ° IWO Consultant UNSMTCHED & SWITCHED i I i ELECTRICAL BOXOUTLETS, SEE NOTE ABOVE. MART ZONE FREESTANDING CESSORY WALLUTUNE OF ° 00 " " p ° ° 0�! L— S —� OPENING ON BACK PANEL FIXTURE �� FIXTURE N ° UNswTTCHED DATA ° °UNswrrCHED DATA ° FH E N D E R S 0 N SEE WALL MOUNTING FINISHED 0'-0" FINISHED 0'-0' a BROWN - CR5362) (BROWN - CR5362) Xj E N G I N E E R SM BRACKET C FOR DETAILIL - � BUSHING PROVIDE (2 DATA FEEDS LINE OF FINISHED FLOOR FLOOR FLOOR \F r FINISHED FLOOR 0'-0' ��111111110119) FOR BRACKET C MOUNTING BRACKET D 8345 LENEXA DRIVE,SUITE 300 FOR FIXTURE SX-15 FOR FIXTURE: SX-11, LENEXA,KS 66214 SX-20 rre111.913 742 5000 FAx 913 742 5001 PROVIDE P-TOUCH LABEL DENOTING 'SWITCHED" www.hel-engAom HOME SOLUTIONS WALL SMART ZONE FREESTANDING ACCESSORY WALL PLUGMOLD DETAIL TYPICAL DATA TYP. THRU—CEILING AND "UNSWiTCHED' CIRCUITING OVER 1550003152 7 PANEL POWER DIAGRAM $ FIXTURE LIGHTING DETAIL 9 LIGHTING DETAIL 1 AT TECH COUNTER (K�NOT PULL STRING DETAIL 1 2 CONDUIT DETAIL 1 3 WALL MOUNTING BRACKET DETAILS CORRESPONDING RECERACLES.NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE TO SCALE NOT TO SCALE NOT TO SCALE Job Name and Number. 2015-ft3l LINE OF SMART ZONE FREE Proposed STANDING DISPLAY WAIL 2 SIDED FIXTURE VERIZON LINE OF SMART ZONE FREE CONDUIT STUB UPS, STANDING DISPLAY WALL 7VERIFY SPACING WiTH 2 SIDED COMPRESSED -BOX KO'S. CONDUIT STUB UPS, STORE FIXTURE CONDUIT SNB UPS, FLOOR MOUNTED Ct FIXTURE VERIFY SPACING WITH VERIFY SPACING WITH 2-GANG MASONRY `� CONDUIT STUB UPS, VERIFY FIXTURE DATA FEED SCHEDULE ____rte__ _ I J-BOX KO'S. .�Q` ; FIXTURE SPACING MTH J-BOX KO'S. (LEED) LU �------------------ r- ------- -, J-BOX KO S. J-BOX r-- ---- ----- -, FLOOR MOUNIID NE OF OPENING IN RE i r [,—LINE OF CASH WRAP i Pmt��S ,% �� 2-GANG MASONRY UNSMTCHED DUPLEX LINE OF BRAND MONOLITH NUMBER OF FIXTURE NUMBER I I I I SWITCHED DUPLEX RECEPTACLE J-BOX RECEPTACLE FOR FIXTURE DATA FEED — j I LINE OF OPENING IN ``'_I S` NE OF OPENING IN FOR FIX URE LIGHTING, COLOR: �S' �� W I I - ----------- = r-------------------- , ' I I I FIXTURE I I FIXTURE BROWN ROUTE SWITCHED CONDUIT STUB UPS, SX-01 SX-02, SX-06 SX-15, I I i �� VERIFY SPACING WITH (1) DATA FEED SX-20 SX-21, BPK DATA BY VERIZON }— _ —�_ I +- CIRCUIT THROUGH CONTACTOR < > �--�-- — +- ' WIRELESS VENDORI I I I ■ `� i J-BOX KO'S. I I I I DATA BY VERIZON I I C1 I I Job Addmw (2) DATA FEEDS SX-07, SX-10, SX-22 I iC3' WIRELESS VENDOR i DATA BY VERIZON I I I I ��� LINE OF NEW RELEASE __________ ___ _ __ Washington Square Mall I I WIRELESS VENDOR CUBE I ----- --------------J I I 1 -3 UNSWITCHED DUPLE( i I UNSWITCHED DUPLEX X LINE OF OPENING IN (3) DATA FEEDS SX-11, SX-16, SX-23, SX-24 FLOOR MOUNTED UNSWITCHED DUPLEX ------------------- -L----- I ______ SWITCHED DUPLEX RECEPTACLE FOR I _ __ ____, RECEPTACLE FOR FIXTURE ��� ; LINE OF OPENING IN FLOOR MOUNTED FIXTURE 8 S.W. Washington 3-GANG MASONRY -------- ------- FIXTURE I I - RECEPTACLE FOR FIXTURE ` FIXTURE 4-GANG MASONRY DATA BY VERIZON Square Road PROVIDE (3) DATA FEEDS RECEPTACLE FOR I I LIGHTING, ROUTE SWITCHED J-BOX J-BOX FIXTURE PROVIDE (3) DATA FEEDS FLOOR MOUNTED i i PROVIDE (1) DATA FEED CIRCUIT THROUGH CONTACTOR DATA BY VERIZON ��� SWITCHED CIRCUIT FOR FIXTURE WIRELESS VENDOR Portland, OR 97223 o PER FIXTURE 2-GANG MASONRY r.- PER FIXTURE r r WIRELESS VENDOR w J-BOX Cl PPROVIDEER FIXTURE DATA FEED CIRCUIT THROUGHSCQNTACTOR PROVIDE (2) DATA FEEDS ITCHED Space R05-R07 N SMART ZONE FREE STANDING DISPLAY WALL CASH WRAP ESSENTIALS PEDESTAL NEW RELEASE CUBE BRAND MONOLITH OrawlngTitle: 0 14 FLOOR BOX LOCATION DIAGRAM 15 FLOOR BOX LOCATION DIAGRAM 1 6 FLOOR BOX LOCATION DIAGRAM F FLOOR BOX LOCATION DIAGRAM 18 FLOOR BOX LOCATION DIAGRAM ELECTRICAL ca 'O NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE DETAILS mU � W c W Q � � O Qto O N m O r 1 Drawn By: on o AUDIO CABLE BY MUSIC SYSTEM LKV N PROVIDER. IN STORE MUSIC PROVIDE (1) ONE 24 LONG a,e&edBy: co a 4-0 LONG 4 0 SLEEVE a WIRING RUN IN CEILING, AND TO WITH BUSHINGS ON TOP 2' SLEEVE WITH BUSHINGS St - �'� AJO 0 0 o PROVIDE (1) ONE 36 LONG o BE COILED AT THE END ABOVE AND BOTTOM IN CEILING FOR ANTENNA I I I IN STORE MUSIC Date issuedFor a I - 2 0 SLEEVE WITH - Client_12424/2015 TELCO RACK. CABLE ACCESS SYSTEM DATA JACK ® a PROVIDE (1) ONE DEDICATED 20AMP r 2 0 TELEPHONE CONDUIT WITH o BUSHINGS IN CEILING FOR HVAC UNIT ■ A.F.F. Landlord; W 0 4-0 LONG 4 0 SLEEVE BUSHINGS TO MAIN POINT OF o ��_ I o CABLE ACCESS o N STORE MUSIC SYSTEM Perrnt�2�2 2015 N a 120/208V DUPLEX RECEPTACLE I WITH BUSHINGS ON TOP ENTRY WITH PULL STRING I 6 .- I ABOVE DOOR J Z IN STORE MUSIC SYSTEM 4"0, 27' LONG PVC TUBE OUTLET (HBL5362GY-GRAY) LABELED `IT N AND BOTTOM N �`' N PROVIDE (1) ONE-/ N ,AUDIO Bid: ONLY" AT THE RACK. CABLE TRAY ABOVE ® +60 A.F.F. 3�-411 ) -6» 6 1 -61 1 PROVIDE 1 ONE DEDICATED 30 CABLE TRAY ABOVE 24' LONG 2" 0 + Construction: POWER DATA & AUDIO ( ) CDMA EVDO 3 1/2rt SLEEVE WITH No. Date DmcWlon OUTLETS FOR IN STORE AMP TWIST LOCK OUTLET 0 +18' REPEATS REP. REP. Revslonlssue 6 / 2 QUAD OUTLET FOR BUSHINGS IN CEILING 3 MUSIC @ +70' A.F.F. A.F.F. (NEMA L5-30R) GROUNDING BAR SECURTiI( 0 74 A.F.F FOR CABLE ACCESS o Ir� LABELED 'UPS' AT THE RACK, „ REPEATER BOX IN STORE MUSIC TELCO RACK 2 PROJECTED FROM WALL REE (3) DATA AND ONE o CABLE TRAY ABOVE 12 LONG BUSS GROUNDING (1) PHONE JACKS FOR �� PUMP SYSTEM POWER r r 12' LONG BUSS GROUNDING BAR BAR 0 +80' A.F.F BY CABLE CELL BURGLAR SECURITY 0 67' All SECURITY PANELS +70' A F.F. LO ® +80' A F.F BY CABLE VENDOR. VENDOR. ELEC. CONTRACTOR PROVIDE (1) ONE DEDICATE BACKUP r ALARM ,�, 20AMP DUPLEX RECEPTACLE /2r, IN STORE MUSIC SYSTEM U 0 20 ELEC. CONTRACTOR TO PROVIDE tt TO PROVIDE WIRE TO o WIRE TO GROUND AND CONNECT I GROUND AND CONNECT TO LABELED 'BDA g +60' A.F.F. to 23 21 cD GROUNDING BAR. oo N I rn TO GROUNDING BAR. c� POWER N 22 J-011 ■ ' " I I I N i� SUPPLY ACCESS t� z 3 2 0 TELEPHONE CONDUIT , „ , „ ) -6 /---PROVIDE (1) ONE DEDICATED 30 N HVAC UNIT ABOVE DOORWITH BUSHINGS 3 -4 -6 AMP TWIST LOCK OUTLET +18' I CONTROL - o c� I N • A.F.F. NEMA L5-30R N �`' POWSECRfiA D DATA FOR 4-0 LONG, 4 ¢ SLEEVE ( ) TELCO RACK to to n i 7g WiTH BUSHINGS LABELED 'UPS' AT THE RACK, N PROVIDE (1) ONE 36' LONG 2'0 D - CD SlEE1lE WITH BUSHINGS IN ROVIDE (1) ONE DEDICATED 20AMP i DUPLEX RECEPTACLE LO �' CEILING FOR CABLE ACCESS • (HBL5362GY-GRAY) LABELED IT In N REPEATER BOX ABOVE MUSIC DrawingNumtkv: > = o REPEATER BOXES SYSTEM, SEE ELEV. ONLY' AT THE RACK. N z SECURITY PANELS N i PROVIDE (1) ONE PROVIDE (1) ONE 2' 0 DEDICATED 20AMP SLEEVE IN CEILING FOR Z TELCO ROOM DETAIL 120/208V DUPLEX ANTENNA CABLE ACCESS ELCO ROOM ELEVATION �NOTTOROOM ELEVATION TELCO ROOM ELEVATION TELCO ROOM ELEVATION X 1 �+ NOT TO SCALE RECEPTACLE LABELED WITH BUSHINGS q§�!NOT TO SCALE 1ALE NOTTO SCALE 2 NOT TO SCALE zi 'BDA' 26 OF 31 J_ 7 GRUSKIN 294 Morris Avenue Springfield,NJ 07081 Tel: 973.376.441 1 Fax:973.376.8989 www.GruskinGroup.com Nj REG 0100-9869-14 This document and the ideas and designs incorporated herein,as an Instrument of professional service, is the property of GRUSKIN ARCHITECTURE+DESIGN,P.C.,and is not to be used in whole or in part for any other project without the written authorization of GRUSKIN ARCHITECTURE+DESIGN,P.C. All Rights Reserved ©2015 Gruskin Architecture+Design,P.C. Keinnih A. Onridn AIA AL 5421 MT 2537 AK 13167 NC 9961 AR 3811 ND 1666 AZ 39209 NE A-3547 CA C-29898 NH 2796 CO ARC-400347 NJ Al 09999 CT 9613 NM 004168 DC ARC100723 NV 5521 DE 0006261 NY 025528-1 NY FL AR91629 OK a4895 GA RA011075 OH 13761 HI AR 11489 FOR 4899 IA 05713 PA RA-0154J2-8 ID AR-984459 PR 19965 IL 001-019152 RI 2666 IN AR10400066 SC 6834 KS 4674 SD 11532 KY 5967 TN 101374 LA 5734 TX 17680 ME ARC 2596 UT 5881358-0301 MD 11016 VT 2572 MA 10635 VA 0401 011223 MI 1301052379 WA 10344 MN 44326 WI 9900-005 MO A-2005029740 WV 3727 MS 3860 WY C-1967 Professional leaf: P R OFFs I N EFS SAO 17547PE o�F R E/ EXPIRES: 12201 Consultant F7HENDERSON Xj ENGINEERS_ ACCESS PANEL OUTLINE OF LIGHT FIXTURE SCHEDULE CA T24 8345LLEENE�DRSIV662�4E300 TABLE LEG TAG MANUFACTURER SYMBOLS CATALOG NO. LAMPS INPUT INPUT DESCRIPTION TEL 913 742 5000 FAx 913 742 5001 1' CONDUIT UTUNE OF NO. TYPE VOLT WATTS VA www.hei-eng.com FOR POWER TABLE ABOVE T 1550003152 1" CONDUIT FOR DATA CR-20 TYC El 1501—R-41-3-0-22—LED-30 1 LED, 3000K 120 41 43 GRID RECESSED, EDGE LIT LED 2'x2' FLAT PANEL Jab Name and Number. 2015-0131 LIGHTING 3600 LUMENS FOR BACK OF HOUSE AREAS. INTEGRAL LED DRIVER. INN FIXTURE T URE OPENING PLAN GRID RECESSED, EDGE LIT LED 2'x2' FLAT PANEL Proposed CR-20 TYC 1501—R-41-3-0-22—LED-30—EM 1 LED, 3000K 120 41 43 FOR BACK OF HOUSE AREAS. INTEGRAL LED DRIVER. —EM LIGHTING 3600 LUMENS PROVIDE WITH EM BATTERY PACK. VERIZON GRID RECESSED, EDGE LIT LED 2'x2' FLAT PANEL CS-20 TYC oro 1501—R-41—3-0-22—LED-30—FK22 1 LED, 3000K 120 41 43 FOR BACK OF HOUSE AREAS. INTEGRAL LED DRIVER. 5�0 R E LIGHTING 3600 LUMENS FLANGE KIT INCLUDED FOR GYP. CEILING MOUNTING. (LEER) I I CP-08 BRUCK 135-700—CH—MP 1 LED, 3000K 120 6 7 SMALL DECORATIVE PENDANT HAVANNA II, DRIVER: P70418-700 CHROME FINISH, LED SOURCE 6" LED 2300 LUMEN DOWNLIGHT IN 3000K. LOCATION OF CR-01 JUNO O L6 23 30 (VOLTAGE) L600P W WH HB—TL 1 LED, 3000K 120 37 41 PROVIDE WITH 0-10V DIMMING. kbAddress ACCESS PANEL 2300 LUMENS WHITE REFLECTOR, WHITE TRIM Washington Square Mall I I I I PULL STRING 9585 S.W. Washington I I CR-01 a JUNO 0 L6 23 30 (VOLTAGE) L600P W WH HB—TL 1 LED, 3000K 120 37 41 6" LED 2300 LUMEN DOWNLIGHT IN 3000K. WHITE 32 I 2300 LUMENS REFLECTOR, WHITE TRIM USE IN DRYWALL SOFFIT Square Road 3 PROVIDE I I Portland, OR 97223 UNC CHER I 11 r CR-02 JUNO n- DCS10 N 10 30 120 WH 2 HB—TL—T569BL 1 LED,3000K 120 15.2 17 ONE—LIGHT ADJUSTABLE LED ACCENT LIGHT, Space R05-R07 'moi 1000 LUMENS 22DEG NARROW BEAM, 3000K, WHITE FINISHES. M 1" CONDUIT I I JUNCTION BOX Drawirgrme o FOR POWER I I (TYP. EACH SIDE) CR-03 JUNO O O O DCS10 FFF 10 30 120 WH 2 HB—TL—T569BL 1 LED,3000K 120 45.6 51 THREE—LIGHT ADJUSTABLE LED ACCENT LIGHT, TELCO ROOM ca LO zQ� FLOOR ON L I W Z I o PROVIDE 1 DATA FEED 1000 LUMENS 22DEG NARROW BEAM, 3000K, WHITE FINISHES. DETAILS V( LIGHT GRADE I I 6" LINER LIGHT SLOT FIXTURE WITH 3000K LED SOURCE; FIXTURE SCHEDULE a j I 1• CONDUIT CR-04 A—LIGHT D6—R(LENGTH)—LS30—U—SH—X—BS—W—D 1 LED,3000K 120 7/FT 8/FT (STANDARD LED OUTPUT) REGRESSED DIFFUSER LENS. a a FOR DATA SEE PLAN FOR FIXTURE RUN LENGTHS. Cn � / • >' �• s e • d 0-10V DIMMING. 01 A 4 a "• . D I y Drawn By: North N Q CR-15 JUNG [Fol DCS10 NN 10 30 120 WH 2 HB—TL—T569BL 1 LED,3000K 120 31 36 TWO—LIGHT ADJUSTABLE LED ACCENT LIGHT, LKV Ar"; N 1000 LUMENS 22DEG NARROW BEAM, 3000K, WHITE FINISHES. a' ted� AJ0 0 s EMERGENCY EXIT SIGN Dee lssuedFor 3 w � K JUNG ® ( NXPB3RWH — LED INCLUDED 120 5 10 (RE: PLANS FOR QTY. OF SIDES AND CHEVRONS) Client 12/24/20-15 Q ��.\ �\ .\� /�� BATTERY BACK—UP FOR MINIMUM 90 MIN. Landlord-, W POWER IN ELEVATION Permit2�2472015 DATA IN MINI GENIE SERIES COMPACT FULLY RECESSED Cn g Zo EM ISOLITE MINI—GENIE #MIGN-25—LC—UN 2 25W MR-11 120 50 51 EMERGENCY LIGHT. CONFIRM FINISH WITH CEILING PLANS 81d. zCOLOR — (BLACK OR WHITE (BLACK OR WHITE) WITH 90 MIN. BATTERY. 414 LUMENS Construction POWER FEED DIAGRAM AT Revslanlssue ONE—CIRCUIT WHITE TRACK WITH INTEGRAL 5—AMP CURRENT No. Date DescrVlon 0 NOTWOSCiLE —05(X') JUNO T2WH, T4WH, T6WH, T8WH NA NA 120 NA NA LIMITER DEVICE. SHALL BE 2013 TITLE 24 COMPLIANT. 0_ I 0 SEE PLAN FOR RUN LENGTH. INTEGRAL LED WALLWASH TRACKHEAD IN 3000K. ~ c-t T-07 JUNO T256LED 3K WH 1 LED, 3000K 120 35 38 PROVIDE WITH DIMMABLE DRIVER AND WHITE FINISHES 0 co M 1806 LUMENS cr' o THERMOPLASTIC LED EXIT SIGN. WHITE FINISH, RED LETTERS. o LO X1 JUNO ® NXPB3RWH — RED LED 120 4 4 (RE: PLANS FOR QTY. OF SIDES AND CHEVRONS) z BATTERY BACK—UP FOR MINIMUM 90 MIN. N NOTE: ALL LIGHT FIXTURES AND LAMPS ARE TO BE PROVIDED BY GENERAL CONTRACTOR PURCHASED FROM VERIZON WIRELESS' VENDOR. N COORDINATE WITH VERIZON WIRELESS PROJECT MANAGER. o N LIGHTING SUPPLIER SHALL BE REQUIRED TO PROVIDE ALL FIXTURE MOUNTING HARDWARE ACCESSORIES (I.E. BRACKETS, CLIPS, ETC, MADE BY THE MANUFACTURER) CD LO I'll NECESSARY TO INSTALL FIXTURES TO CEILING GRIDS OR FRAMING MEMBERS FOR MOUNTINGS INDICATED IN THE DRAWINGS. in oPROVIDE A FACTORY INSTALLED MAXIMUM WATTAGE LABEL ON ALL MEDIUM SCREW BASE LIGHT FIXTURES, THAT CORRESPOND TO THE MAXIMUM WATTAGE INDICATED Drawln Number: oIN THE LIGHT FIXTURE SCHEDULE. THE MARKINGS SHALL BE PERMANENTLY INSTALLED, IN LETTERS AT LEAST 1/4" HIGH, AND SHALL BE LOCATED WHERE VISIBLE DURING RELAMPING. g N � a_ 8 LIGHT FIXTURE SCHEDULE o 0 Z NOT TO SCALE E5aX C 7 OF 31 I i * GRUSKIN 16A EXISTING EQUIPMENT REUSE AND REMOVAL 244 Morris Avenue Springfield,NJ 07081 Tel16A SEISMIC CONTROLS FOR MEPF SYSTEMS SECTION 16A GENERAL ELECTRICAL REQUIREMENTS - REV 041013: www.GruskiriGroup.com ou omFaxNJRGO]OD-8484 REMOVE ALL EXISTING WIRING, LIGHT FIXTURES, EXPOSED CONDUITS AND OTHER www.GruskinGroup.com NJ REG 0100.9864-14 SEISMIC PROTECTION CRITERIA: 16A GENERAL INSTRUCTIONS WHERE CONFLICTS BETWEEN VARIOUS CODES, ORDINANCES, RULES, AND EXCAVATION AS HEREIN SPECIFIED SHALL BE CLASSIFIED AS COMMON EXCAVATION. 16A FIRE-STOPPING THROUGH PENETRATIONS ELECTRICAL INSTALLATIONS NOT REUSED PRIOR TO SUBSTANTIAL COMPLETION OF REGULATIONS EXIST, COMPLY WITH THE MOST STRINGENT. WHEREVER COMMON EXCAVATION SHALL COMPRISE THE SATISFACTORY REMOVAL AND THE WORK. This document and the ideas and designs incorporated RISK/OCCUPANCY CATEGORY: I 16A GENERAL REQUIREMENTS REQUIREMENTS OF THESE SPECIFICATIONS, DRAWINGS, OR BOTH, EXCEED THOSE DISPOSITION OF MATERIAL OF WHATEVER SUBSTANCES AND OF EVERY FIRE-RESISTANT THROUGH PENETRATION SEALANTS: TWO-PART, FOAMED-IN-PLACE, herein,as an Instrument of professional service, Is the OF THE ABOVE ITEMS, THE REQUIREMENTS OF THESE SPECIFICATIONS, DRAWINGS, DESCRIPTION ENCOUNTERED, INCLUDING ROCK, IF ANY, WITHIN THE LIMITS OF THE SILICONE SEALANT FORMULATED FOR USE IN THROUGH-PENETRATION FIRE- EXISTING RACEWAYS MAY BE REUSED IF THEIR POINTS OF TERMINATIONS ARE ro of GRUSKIN ARCHITECTURE+DESIGN,P.C.and SITE SOIL CATEGORY: CONTRACTOR'S SEISMIC i not ALL RE UIREME THE GENERAL AND SUPPLEMENTARY SHOWN ON THE DRAWINGS. T ARE CLEAN INSIDE WITH NO EVIDENCE OF RUST OR BURRS; IF Q NTS UNDER DIVISION 1 AND OR BOTH, SHALL GOVERN. CODE COMPLIANCE, AT A MINIMUM, IS MANDATORY. WORK AS SPECIFIED AND NGS. EXCAVATION SHALL BE STOPPING AROUND CABLES, RACEWAYS, AND CABLE TRAY PENETRATIONS SUITABLE; IF THEY is not to be used in whole or in part ocherproject ENGINEER TO DETERMINE CONDITIONS OF THESE SPECIFICATIONS APPLY TO THIS SECTION AND DIVISION. CONSTRUE NOTHING IN THESE CONSTRUCTION DOCUMENTS AS PERMITTING WORK PERFORMED TO THE LINES AND GRADES INDICATED ON THE DRAWINGS. DISPOSE THROUGH FIRE-RATED WALLS AND FLOORS. SEALANTS AND ACCESSORIES SHALL FREE FROM CRACKS, FLATTENED SECTIONS OR SHARP BENDS; AND, IF SUITABLY authorization Y SIESMIC DESIGN CATEGORY: D WHERE THE REQUIREMENTS OF THIS SECTION AND DIVISION EXCEED THOSE OF NOT IN COMPLIANCE, AT A MINIMUM, WITH THESE CODES. OF EXCAVATED MATERIALS THAT ARE CONSIDERED UNSUITABLE FOR BACKFILL, AND HAVE FIRE-RESISTANCE RATINGS INDICATED, AS ESTABLISHED BY TESTING LOCATED TO AVOID CONFLICTS WITH OTHER TRADES OR INSTALLATIONS. without thew+DESIGN,P.tten atlanof GRUSKIN COMPONENT IMPORTANCE FACTOR: DETERMINED FROM DIVISION 1, THIS SECTION AND DIVISION TAKE PRECEDENCE. BECOME THOROUGHLY SURPLUS OF EXCAVATED MATERIAL, WHICH IS NOT REQUIRED FOR BACKFILL, ALL TO IDENTICAL ASSEMBLIES IN ACCORDANCE WITH ASTM E 814, BY UNDERWRITERS' CAREFULLY "FISH" ALL EXISTING CONDUITS REUSED UNDER THIS CONTRACT TO ARCHITECTURE+DESIGN,P.C. FAMILIAR WITH ALL THEIR CONTENTS AS TO REQUIREMENTS THAT AFFECT THIS PROMPTLY BRING ALL CONFLICTS OBSERVED BETWEEN CODES, ORDINANCES, THE SATISFACTION OF THE ENGINEER. LABORATORIES, INC., OR OTHER NRTL ACCEPTABLE TO AHJ. REMOVE ALL DEBRIS AND OBSTRUCTIONS, AND SWAB UNTIL ALL MOISTURE IS AIIRtghtsReserved 2012 IBC DIVISION, SECTION OR BOTH. WORK REQUIRED UNDER THIS DIVISION INCLUDES ALL RULES, REGULATIONS, REFERENCED STANDARDS, AND THESE DOCUMENTS TO THE REMOVED. ©2015GruskinArchitecture+Design,P.C. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING MATERIAL, EQUIPMENT, APPLIANCES, AND LABOR REQUIRED TO COMPLETE THE ENGINEER'S ATTENTION FOR FINAL RESOLUTION. CONTRACTOR WILL BE HELD 16A COINCIDENTAL DAMAGE ACCEPTABLE MANUFACTURERS: THE REQUIREMENTS FOR SEISMIC BRACING OF MECHANICAL, ENTIRE ELECTRICAL SYSTEM AS REQUIRED BY THE DRAWINGS AND RESPONSIBLE FOR ANY VIOLATION OF THE LAW. CUT, PATCH, AND REPAIR WHERE REQUIRED FOR NEW ELECTRICAL INSTALLATIONS, KamwO A. ftu" AIIA ELECTRICAL, AND PLUMBING SYSTEMS. SEISMIC PROTECTION SPECIFICATIONS, OR REASONABLY INFERRED TO BE NECESSARY TO FACILITATE REPAIR ALL STREETS, SIDEWALKS, DRIVES, PAVING, WALLS, FINISHES, AND OTHER HILTI, INC. AND PATCH AND REPAIR ALL SURFACE DAMAGE RESULTING FROM THIS WORK. CUT EACH SYSTEM'S FUNCTIONING AS IMPLIED BY THE DESIGN AND THE EQUIPMENT PROVIDE AND MAINTAIN ALL NECESSARY SIGNAL LIGHTS AND GUARDS FOR THE FACILITIES DAMAGED IN THE COURSE OF THIS WORK. REPAIR MATERIALS SHALL 3M CORP. FLUSH WITH THE FLOOR AND PLUG AT BOTH ENDS, RACEWAYS STUBBED ABOVE THE CRITERIA USED TO DETERMINE SEISMIC BRACING SPECIFIED. SAFETY OF THE PUBLIC. OBTAIN AND PAY FOR ALL PERMITS FOR WORK IN THIS MATCH EXISTING CONSTRUCTION. ALL BACKFILLING AND REPAIRING SHALL MEET RECTORSEAL. FLOOR AND NOT USED AT SUBSTANTIAL COMPLETION OF THE WORK. AL 5421 MT 2537 REQUIREMENTS OF ALL MECHANICAL, ELECTRICAL AND DIVISION. ALL REQUIREMENTS OF THE OWNER, CITY AND OTHERS HAVING JURISDICTION. SPECIFY TECHNOLOGY INC. AK 13167 NC 9961 PLUMBING SYSTEMS SHALL BE DETERMINED BY THE THE SPECIFICATIONS AND DRAWINGS FOR THE PROJECT ARE COMPLEMENTARY, REPAIR WORK SHALL BE THOROUGHLY FIRST CLASS. CONFORM TO ALL UNITED STATES GYPSUM COMPANY. RELOCATE ALL EXISTING ELECTRICAL SYSTEMS REQUIRED TO BE IN OPERATION AT AR 3811 ND 1666 APPLICABLE CODE ADOPTED IN THE PROJECT JURISDICTION. AND PORTIONS OF THE WORK DESCRIBED IN ONE, SHALL BE PROVIDED AS IF 16A PROTECTION OF EQUIPMENT AND MATERIALS REQUIREMENTS OF DIVISION 2 OF THESE SPECIFICATIONS. SUBSTANTIAL COMPLETION OF THE CONTRACT, IF REQUIRED, AS A RESULT OF AZ 39209 NE A-3547 WHERE NOT ALREADY DETERMINED WITHIN THE CONTRACT DESCRIBED IN BOTH. IN THE EVENT OF DISCREPANCIES, NOTIFY THE ENGINEER AND SUBMITTALS WORK INCLUDED UNDER THIS CONTRACT, EVEN IF NOT SPECIFICALLY INDICATED IN CA C-29898 NH 2796 REQUEST CLARIFICATION PRIOR TO PROCEEDING WITH THE WORK INVOLVED. STORE AND PROTECT FROM DAMAGE EQUIPMENT AND MATERIALS DELIVERED TO 16A CUTTING AND PATCHING THE DRAWINGS OR SPECIFICATIONS. CO ARC-400347 NJ AI 09999 DOCUMENTS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR JOB SITE, IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS. FOR SUBMIT PRODUCT DATA, MANUFACTURER'S SPECIFICATIONS AND TECHNICAL DATA CT 9613 NM 004168 CONTRACTING A LICENSED PROFESSIONAL ENGINEER TO DRAWINGS ARE GRAPHIC REPRESENTATIONS OF THE WORK UPON WHICH THE MATERIALS AND EQUIPMENT SUSCEPTIBLE TO CHANGING WEATHER CONDITIONS, FOLLOWING THE REQUIREMENTS IN DIVISION 1, CUT WALLS, FLOORS, CEILINGS, AND FOR EACH MATERIAL INCLUDING THE COMPOSITION AND LIMITATIONS, EXISTING SERVICE ENTRANCE CONDUCTORS AND FEEDER CONDUCTORS MAY BE DC C 00 NV 5521 CONTRACT IS BASED. THEY SHOW THE MATERIALS AND THEIR RELATIONSHIP TO DAMPNESS, OR TEMPERATURE VARIATIONS, STORE INSIDE IN CONDITION SPACES. OTHER PORTIONS OF THE FACILITY AS REQUIRED TO PERFORM WORK UNDER THIS DOCUMENTATION OF UL FIRESTOP SYSTEMS TO BE USED AND MANUFACTURER'S REUSED IF ALL OF THE FOLLOWING CONDITIONS ARE MET: AR 1 723 ESTABLISH BUILDING SITE CLASS, SEISMIC DESIGN CATEGORY, ONE ANOTHER, INCLUDING SIZES, SHAPES, LOCATIONS, AND CONNECTIONS. THEY FOR MATERIALS AND EQUIPMENT NOT SUSCEPTIBLE TO THESE CONDITIONS, COVER DIVISION. OBTAIN PERMISSION OF THE ENGINEER, OWNER, OR BOTH, BEFORE INSTALLATION INSTRUCTIONS TO COMPLY WITH DIVISION 1. DE 0006261 NY 025528-1 NY SEISMIC ZONE OR ANY OTHER CRITERIA NECESSARY TO 1. CONDUCTOR SIZES MEET OR EXCEED THE SIZES SPECIFIED ON THE DRAWINGS. FL AR91629 OK a4895 ALSO CONVEY THE SCOPE OF WORK, INDICATING THE INTENDED GENERAL WITH WATERPROOF, TEAR-RESISTANT, HEAVY TARP OR POLYETHYLENE PLASTIC AS DOING ANY CUTTING. CUT ALL HOLES AS SMALL AS POSSIBLE. PATCH WALLS, DETERMINE THE REQUIREMENTS FOR SEISMIC BRACING ON ARRANGEMENT OF THE EQUIPMENT, FIXTURES, OUTLETS AND CIRCUITS WITHOUT REQUIRED TO PROTECT FROM PLASTER, DIRT, PAINT, WATER, OR PHYSICAL FLOORS, AND OTHER PORTIONS OF THE FACILITY AS REQUIRED BY WORK UNDER MANUFACTURER'S ENGINEERING JUDGMENT IDENTIFICATION NUMBER AND GA RA011075 OH 13761 MECHANICAL, ELECTRICAL AND/OR PLUMBING SYSTEMS. SHOWING ALL OF THE EXACT DETAILS AS TO ELEVATIONS, OFFSETS, CONTROL DAMAGE. EQUIPMENT AND MATERIAL THAT HAS BEEN DAMAGED BY CONSTRUCTION THIS DIVISION. ALL PATCHING SHALL BE THOROUGHLY FIRST CLASS AND SHALL DRAWING DETAILS WHEN NO UL SYSTEM IS AVAILABLE FOR AN APPLICATION. 2. CONDUCTOR INSULATION IS IN GOOD OR BETTER CONDITION. HI AR 11489 F OR 4899 LINES, AND OTHER INSTALLATION REQUIREMENTS. USE THE DRAWINGS AS A GUIDE ACTIVITIES WILL BE REJECTED, AND CONTRACTOR SHALL FURNISH NEW EQUIPMENT MATCH THE ORIGINAL MATERIAL AND CONSTRUCTION, INCLUDING FIRE RATINGS IF ENGINEERING JUDGMENT SHALL INCLUDE BOTH PROJECT NAME AND IA 05713 PA RA-015 32-B WHEN LAYING OUT THE WORK AND TO VERIFY THAT MATERIALS AND EQUIPMENT AND MATERIAL OF A LIKE KIND. APPLICABLE. CONTRACTOR'S NAME WHO WILL INSTALL FIRESTOP SYSTEM AS DESCRIBED IN 3. CONDUCTOR INSULATION IS THE CORRECT TYPE FOR THE CONDITIONS. ID AR-984459 PR 19965 SEISMIC BRACING OF FIRE PROTECTION SYSTEMS SHALL BE WILL FIT INTO THE DESIGNATED SPACES, AND WHICH, WHEN INSTALLED PER DRAWINGS. IL 001-019152 RI 2666 INSTALLED IN STRICT ACCORDANCE WITH THE PROVISIONS OF MANUFACTURERS' REQUIREMENTS, WILL ENSURE A COMPLETE, COORDINATED, PLUG OR CAP OPEN ENDS OF CONDUITS WHILE STORED AND INSTALLED DURING 16A ROUGH-IN 16A ALTERNATES IN AR10400066 SC 6834 NEPA 132010 OR LATER EDITION). SATISFACTORY AND PROPERLY OPERATING SYSTEM. CONSTRUCTION WHEN NOT IN USE TO PREVENT THE ENTRANCE OF DEBRIS INTO SUBMIT MATERIAL SAFETY DATA SHEETS PROVIDED WITH PRODUCT DELIVERED TO ( INCLUDE ALL LABOR, MATERIALS, EQUIPMENT AND SERVICES NECESSARY FOR AND KS 4674 SD 11532 THE SYSTEMS. COORDINATE WITHOUT DELAY ALL ROUGHING-IN WITH OTHER DIVISIONS. CONCEAL JOB-SITE. INCIDENTAL TO THE COMPLETION OF ALL WORK UNDER EACH PARTICULAR KY 5967 TN 101374 DRAWINGS ARE SCHEMATIC IN NATURE, SHOW THE VARIOUS COMPONENTS OF THE ALL RACEWAYS EXCEPT IN UNFINISHED AREAS AND WHERE OTHERWISE INDICATED THE CONTRACTOR SHALL DETERMINE THE TYPE AND LOCATION ALTERNATE. FURNISH SEPARATE BIDS FOR EACH APPLICABLE ALTERNATE, STATING LA 5734 TX 17680 SYSTEMS APPROXIMATELY SCALE AND ATTEMPT TO INDICATE HOW THEY SHALL 16A SUBSTITUTIONS ON THE DRAWINGS. 16A CONCRETE BASES THE AMOUNT TO BE ADDED TO OR DEDUCTED FROM THE BASE BID FOR EACH ME ARC 2596 UT 5881358-0301 OF SEISMIC BRACING REQUIRED FOR THE MECHANICAL BE INTEGRATED WITH OTHERR PARTS OF THE WORK. FIGURED DIMENSIONS TAKE ALTERNATE ACCEPTED. APPLICABLE SECTIONS OF THE BASE SPECIFICATIONS MD 11016 VT 2572 ELECTRICAL AND PLUMBING ELEMENTS SHOWN ON THE PRECEDENCE TO SCALED DIMENSIONS. DETERMINE EXACT LOCATIONS BY JOB INCLUDE IN THE BASE BID THE PRODUCTS SPECIFICALLY NAMED IN THESE 16A SUPPORT SYSTEMS PROVIDE CONCRETE BASES (E.G., HOUSEKEEPING PADS) FOR EQUIPMENT WHERE APPLY TO ALL WORK REQUIRED BY THE ALTERNATES UNLESS OTHERWISE DRAWINGS BASED ON THE ESTABLISHED SEISMIC CRITERIA, THE MEASUREMENTS, BY CHECKING THE REQUIREMENTS OF OTHER TRADES, AND BY SPECIFICATIONS OR ON THE DRAWINGS. SUBMIT, IN THE FORM OF ALTERNATES, INDICATED ON THE DRAWINGS AND AS SPECIFIED HEREIN. CONCRETE BASES SHALL TION OF THE SPECIFICATIONS FOR MA 10635 VA 0401 011223 REVIEWING ALL CONTRACT DOCUMENTS. CORRECT ERRORS THAT COULD HAVE WITH BID, PRODUCTS OF ANY OTHER MANUFACTURERS FOR SIMILAR USE, 1. STEEL SLOTTED SUPPORT SYSTEMS (SLOTTED CHANNEL): COMPLY WITH MFMA-3, HAVE CHAMFERED EDGES. SIZE OF BASE SHALL BE A MINIMUM OF 2 INCHES SPECIFIED. REFER TO THE ARCHITECTURAL POR MI 1301052379 WA 10344 SIZE AND WEIGHT OF THE SUPPORTED ELEMENT AND THE BEEN AVOIDED BY PROPER CHECKING AND INSPECTION, AT NO ADDITIONAL COST PROVIDED THE DIFFERENCES IN COST, IF ANY, ARE INCLUDED FOR EACH PROPOSED FACTORY-FABRICATED COMPONENTS FOR FIELD ASSEMBLY; 12-GAUGE, 1-5/8-INCH GREATER THAN THE FOOTPRINT OF THE EQUIPMENT THAT IT IS SUPPORTING. THE LIST OF ALTERNATES. MN 44.326 M 9900-005 DISTANCE FROM STRUCTURE OF THE SUPPORTED ELEMENT. TO THE OWNER. ALTERNATE. BY 1-5/8-INCH; COOPER B-LINE, ERICO INTERNATIONAL CORPORATION, HILTI, INC., MO A-2005029740 WV 3727 POWER-STRUT, THOMAS & BETTS CORPORATION, UNISTRUT. CONSTRUCT EQUIPMENT BASES OF A MINIMUM 28-DAY, 4000-PSI CONCRETE M$ 3860 WY C-1967 THE CONTRACTOR SHALL SUBMIT THE FOLLOWING SHOP SPECIFICATIONS DEFINE THE QUALITATIVE REQUIREMENTS FOR PRODUCTS, PRIOR TO THE BID DATE, SUBSTITUTIONS WILL NOT BE CONSIDERED UNLESS CONFORMING TO AMERICAN CONCRETE INSTITUTE STANDARD BUILDING CODE FOR SECTION 168 BASIC ELECTRICAL MATERIALS AND METHODS - REV MATERIALS, AND WORKMANSHIP UPON WHICH THE CONTRACT IS BASED. SUBMITTED FOR ENGINEER'S REVIEW, AT LEAST TEN CALENDAR DAYS PRIOR TO THE FINISHES: REINFORCED CONCRETE (ACI 318-99) AND THE LATEST APPLICABLE I'mfessionalSeal: DRAWING INFORMATION TO THE AUTHORITY HAVING 081214 JURISDICTION AND THE ENGINEER OF RECORD FOR REVIEW DATE FOR RECEIPT OF BIDS. INCLUDE THE NAME OF THE MATERIAL OR EQUIPMENT A. METALLIC COATINGS: HOT-DIP GALVANIZED AFTER FABRICATION AND APPLIED RECOMMENDATIONS OF THE ACI STANDARD PRACTICE MANUAL. CONCRETE SHALL 16A DEFINITIONS FOR WHICH IT IS TO BE SUBSTITUTED AND A COMPLETE DESCRIPTION OF THE ACCORDING TO MFMA-3. BE COMPOSED OF CEMENT CONFORMING TO ASTM C 150 TYPE I, AGGREGATE METALLIC CONDUIT AND TUBING: AND APPROVAL: (1) SEISMIC ANALYSIS LISTING ALL WHENEVER USE I THESE SPECIFICATIONS OR DRAWINGS THE FOLLOWING TERMS PROPOSED SUBSTITUTE INCLUDING CUTSHEETS, PHOTOMETRIC DATA, AND ALL CONFORMING TO ASTMP3,RCAND AIRPOTABLE WATER. EXPOSED EXTERIOR CONCRETE g PR`O'F APPLICABLE SEISMIC DESIGN CRITERIA (2) DESCRIPTIVE D N ESE S ECIFICATIO OTHER INFORMATION NECESSARY FOR AN EVALUATION FOR EACH SUCH REQUEST. B. NONMETALLIC COATINGS: MANUFACTURER'S STANDARD PVC, POLYURETHANE L CONTAIN 5 TO PERCENT E ELECTRICAL METALLIC TUBING, COUPLINGS AND FITTINGS (EMT): ANSI C80.3, UL 797. G �S SHALL HAVE THE INDICATED MEANINGS: PROVIDE FACTORY GENERATED POINT-BY-POINT CALCULATIONS FOR ALL EXTERIOR OR POLYESTER COATING APPLIED ACCORDING TO MFMA-3. ONLY STEEL PRODUCTS ALLOWED. GINS / CATALOG DATA OF SEISMIC BRACING MATERIALS, (3) SHOP LIGHT FIXTURES (PHOTOMETRIC FILES SUPPLIED SO THE ENGINEER CAN GENERATE UNLESS OTHERWISE SPECIFIED OR SHOWN ON THE STRUCTURAL DRAWINGS, REDUCED WALL EMT IS NOT ALLOWED i DRAWINGS SHOWING BRACING TYPE AND LOCATION, (4) FURNISH: "TO SUPPLY AND DELIVER TO THE PROJECT SITE, READY FOR UNLOADING, A POINT-BY-POINT DO NOT SUFFICE FOR THE POINT-BY-POINT CALCULATIONS). C. PAINTED COATINGS: MANUFACTURER'S STANDARD PAINTED COATING APPLIED REINFORCE EQUIPMENT BASES WITH NO. 4 REINFORCING BARS CONFORMING TO 547PE 9c' INSTALLATION DETAILS OF ALL BRACING USED AND (5) UNPACKING, ASSEMBLING, INSTALLING, AND SIMILAR OPERATIONS." PROVIDE INTERIOR POINT-BY-POINT CALCULATIONS AT THE DISCRETION OF THE ACCORDING TO MFMA-3. ASTM A 615 OR 6X6 - W2.9 X W2.9 WELDED WIRE MESH CONFORMING TO ASTM A185. FLEXIBLE METAL CONDUIT (FMC): ZINC-COATED STEEL OR ALUMINUM, UL 1. CALCULATIONS SHOWING THAT THE SEISMIC RESTRAINTS MEET ENGINEER. SUBMIT A $100.00 REVIEW FEE TO THE ENGINEER WITH EACH SUCH PLACE REINFORCING BARS 24 INCHES ON CENTER WITH A MINIMUM OF TWO BARS REDUCED-WALL FMC IS NOT ALLOWED INSTALL: "TO PERFORM ALL OPERATIONS AT THE PROJECT SITE, INCLUDING, BUT POINT-BY-POINT CALCULATION FOR USE OF ELECTRONIC BASE FILES. 2. ALUMINUM SLOTTED SUPPORT SYSTEMS (SLOTTED CHANNEL): COMPLY WITH MFMA- EACH DIRECTION. Z THE SEISMIC REQUIREMENTS. SHOP DRAWINGS AND NOT LIMITED TO, AND AS REQUIRED: UNLOADING, UNPACKING, ASSEMBLING, 3, TYPE 6063-T6, PER ASTM B221; FACTORY-FABRICATED COMPONENTS FOR FIELD INTERMEDIATE METAL CONDUIT (IMC): HOT-DIP GALVANIZED RIGID STEEL CONDUIT: CALCULATIONS SHALL BE SIGNED AND SEALED BY A ERECTING, PLACING, ANCHORING, APPLYING, WORKING TO DIMENSION, FINISHING, AFTER THE BID DATE, PROPOSALS TO SUBSTITUTE LIGHT FIXTURES FOR THOSE ASSEMBLY; 12-GAUGE, 1-5/8-INCH BY 1-5/8-INCH; COOPER B-LINE, ERICO PROVIDE GALVANIZED ANCHOR BOLTS FOR EQUIPMENT PLACED ON CONCRETE ANSI C80.6, UL 1242. L OREGO REGISTERED PROFESSIONAL ENGINEER LICENSED IN THE STATE CURING, PROTECTING, CLEANING, TESTING, COMMISSIONING, STARTING UP AND SHOWN ON THE DRAWINGS OR SPECIFIED HEREIN, WILL ONLY BE CONSIDERED AS A INTERNATIONAL CORPORATION, HILTI, INC., POWER-STRUT, THOMAS & BETTS BASES OR ON CONCRETE SLABS. ANCHOR BOLTS SIZE, NUMBER AND PLACEMENT 0 Cc1� c 5- \S OF THE PROJECT AND EMPLOYED BY THE MANUFACTURER OF SIMILAR OPERATIONS, COMPLETE, AND READY FOR THE INTENDED USE.' DEDUCT. SUBMIT PROPOSED SUBSTITUTIONS SEPARATELY, IN SUBMITTAL FORM, CORPORATION, UNISTRUT. SHALL BE AS RECOMMENDED BY THE MANUFACTURER OF THE EQUIPMENT. LIQUIDTIGHT FLEXIBLE METAL CONDUIT (LFMC): FLEXIBLE STEEL CONDUIT WITH PVC �9� BAR �P WITH A LIST OF PROPOSED SUBSTITUTIONS TOGETHER WITH A DEDUCT PRICE FOR JACKET: UL 360 THE SEISMIC BRACING PRODUCTS. CALCULATIONS SHALL PROVIDE: "TO FURNISH AND INSTALL COMPLETE, AND READY FOR THE INTENDED EACH SUBSTITUTION. THE ENGINEER WILL THEN REVIEW THE PROPOSED FIELD FABRICATION: CONCRETE EQUIPMENT BASES SHALL HAVE A MINIMUM HEIGHT OF 4 INCHES AND R. INCLUDE DEAD LOADS, STATIC SEISMIC LOADS AND CAPACITY USE." SUBSTITUTIONS. SHALL BE POURED-IN-PLACE. RIGID METAL CONDUIT (RMC): HOT-DIP GALVANIZED RIGID STEEL CONDUIT (GRS): j;/C/ OF MATERIALS UTILIZED FOR CONNECTIONS. WHERE FIELD CUTTING OF STANDARD LENGTHS OF CHANNEL ARE REQUIRED, ANSI C80.1, UL 6. :PINE : 12/31'/2016 FURNISHED BY OWNER (OR OWNER-FURNISHED) OR FURNISHED BY OTHERS: "AN THE ENGINEER WILL HAVE THE FINAL AUTHORITY AS TO WHETHER THE LIGHT MAKE CUTS STRAIGHT AND PERPENDICULAR TO MANUFACTURED SURFACES. 16A ACCESS DOORS ITEM FURNISHED BY THE OWNER OR UNDER OTHER DIVISIONS OR CONTRACTS, AND FIXTURE IS AN ACCEPTABLE REPLACEMENT TO THE SPECIFIED ITEM. THE PLASTIC-COATED IMC, RMC, AND FITTINGS: NEMA RN 1, UL LISTED. SEISMIC BRACING, RESTRAINTS, ISOLATORS, AND ISOLATION INSTALLED UNDER THE REQUIREMENTS OF THIS DIVISION, COMPLETE, AND READY PROPOSED SUBSTITUTION MAY ALSO BE REJECTED BY THE ARCHITECT, THE FOR FIELD-CUT OR DAMAGED SURFACES OF COATED CHANNELS, DRESS CUT PROVIDE ACCESS DOORS IN CEILINGS AND WALLS, WHERE INDICATED OR REQUIRED Consultant MATERIALS SHALL BE OF THE SAME MANUFACTURER AND FOR THE INTENDED USE, INCLUDING ALL ITEMS AND SERVICES INCIDENTAL TO THE ENGINEER OR THE OWNER FOR AESTHETIC REASONS IF FELT NECESSARY OR ENDS, DAMAGED SURFACES, OR BOTH, WITH AN ABRASIVE MATERIAL (E.G., FILE, FOR ACCESS OR MAINTENANCE TO CONCEALED EQUIPMENT INSTALLED UNDER THIS IMC AND RMC FITTINGS: NEMA FB 1; COMPATIBLE WITH CONDUIT TYPE AND WORK NECESSARY FOR PROPER INSTALLATION AND OPERATION. INCLUDE THE DESIRABLE. IN THE EVENT THE PROPOSED SUBSTITUTIONS HEREIN DESCRIBED ARE GRINDING STONE, OR SIMILAR) AND CLEANSER TO REMOVE OILS, RUST, SHARP SECTION. PROVIDE CONCEALED HINGES, SCREWDRIVER-TYPE LOCK, AND ANCHOR SHALL BE CERTIFIED BY THE MANUFACTURER. APPROVED MATERIAL, UL LISTED MANUFACTURERS ARE: AMBER/BOOTH COMPANY, INC., INSTALLATION UNDER THE WARRANTY REQUIRED BY THIS DIVISION. REJECTED, FURNISH THE SPECIFIED ITEM. EDGES AND SHARDS. STRAPS. KINETICS NOISE CONTROL, INC., LOOS & COMPANY, INC., ENGINEER: WHERE REFERENCED IN THIS DIVISION, "ENGINEER" IS THE ENGINEER OF 16A ELECTRONIC DRAWING FILES FOR CHANNEL WITH A FACTORY-APPLIED COATING, RE-FINISH CUT EDGES WITH MANUFACTURED BY MILCOR, ZURN, TITUS, OR EQUAL. OBTAIN ARCHITECT'S NON-METALLIC CONDUIT AND TUBING: MASON INDUSTRIES, INC., UNI-STRUT, VIBRO-ACOUSTICS, OR RECORD AND THE DESIGN PROFESSIONAL FOR THE WORK UNDER THIS DIVISION, A COATING COMPATIBLE WITH THE FACTORY FINISH AND AS RECOMMENDED BY APPROVAL OF TYPE, SIZE, LOCATION AND COLOR BEFORE ORDERING. RIGID NONMETALLIC CONDUIT (RNC): SCHEDULE 40 PVC, 90 DEG C RATED, NEMA TC- HENDERSON AND IS A CONSULTANT TO, AND AN AUTHORIZED REPRESENTATIVE OF, THE IN PREPARATION OF SHOP DRAWINGS OR RECORD DRAWINGS, CONTRACTOR MAY, THE MANUFACTURER (E.G., MANUFACTURER'S TOUCH-UP PAINT OR ZINC-RICH LINE . EACH DEVICE SHALL HAVE APRE-APPROVAL ARCHITECT, AS DEFINED IN THE GENERAL AND/OR SUPPLEMENTARY CONDITIONS. AS AN OPTION, OBTAIN ELECTRONIC DRAWING FILES IN AUTOCAD OR DXF FORMAT COLD-GALVANIZING COMPOUND, AS APPLICABLE). 16A EQUIPMENT FURNISHED BY OTHERS 2, UL 651; FITTINGS: NEMA TC 3, TC 6; UL 514, COMPATIBLE WITH CONDUIT/TUBING NUFROM NUMBER FROM CALIFORNIA OSHPD OR OTHER RECOGNIZED / TYPE AND MATERIAL, UL LISTED. r17JENGINEERSM NU WHEN USED IN THIS DIVISION, IT MEANS INCREASED INVOLVEMENT BY, AND FROM THE ENGINEER FOR A SHIPPING AND HANDLING FEE OF $200 FOR A DRAWING 16A PENETRATIONS GOVERNMENT AGENCY SHOWING MAXIMUM RESTRAINT RATINGS. OBLIGATIONS TO, THE ENGINEER, IN ADDITION TO INVOLVEMENT BY, AND SET UP TO 12 SHEETS AND $15 PER SHEET FOR EACH ADDITIONAL SHEET. CONTACT PROVIDE NECESSARY EQUIPMENT AND ACCESSORIES THAT ARE NOT PROVIDED BY 16B RACEWAY INSTALLATION 8345 LENEXA DRIVE,SUITE 300 OBLIGATIONS TO, THE "ARCHITECT". THE ARCHITECT FOR WRITTEN AUTHORIZATION; AND, CONTACT THE ENGINEER TO THE EQUIPMENT SUPPLIER OR OWNER TO COMPLETE INSTALLATION OF EQUIPMENT 14 SEISMIC BRACING MEASURES TO BE APPLIED TO COORDINATE SLEEVE SELECTION AND APPLICATION WITH SELECTION AND LENEXA,KS FAx 91 OBTAIN THE NECESSARY RELEASE AGREEMENT FORM AND TO INDICATE THE FURNISHED BY OTHERS, IN LOCATIONS AS INDICATED ON THE DRAWINGS, SPECIFIED ABOVE GROUND USE AHJ: THE LOCAL CODE AND/OR INSPECTION AGENCY (AUTHORITY) HAVING DESIRED SHIPPING METHOD AND DRAWING FORMAT. IN ADDITION TO PAYMENT, APPLICATION FI FIRE-STOPPING SPECIFIED IN DIVISION 7 SECTION "THROUGH- HEREIN, OR BOTH. EQUIPMENT AND ACCESSORIES NOT PROVIDED BY THE INSTALL ALL CIRCULAR RACEWAYS CONCEALED ABOVE SUSPENDED CEILINGS OR TEL 913 742 5000 fFA7F 413 742 5001 MECHANICAL/ELECTRICAL/PLUMBING EQUIPMENT AND SYSTEMS JURISDICTION OVER THE WORK. ARCHITECT'S WRITTEN AUTHORIZATION AND ENGINEER'S RELEASE AGREEMENT PENETRATION FIRESTOP SYSTEMS. EQUIPMENT SUPPLIER MAY INCLUDE SUCH ITEMS AS FLEXIBLE CORDS AND PLUGS, CONCEALED IN WALLS OR FLOORS WHEREVER POSSIBLE EXCEPT WHERE www.hei-eng.eom SHALL BE INSTALLED IN STRICT ACCORDANCE WITH ALL FORM MUST BE RECEIVED BEFORE ELECTRONIC DRAWING FILES WILL BE SENT. AS REQUIRED FOR PROPER OPERATION OF THE COMPLETE SYSTEM, IN OTHERWISE INDICATED. APPLICABLE LOCAL, STATE, AND/OR FEDERAL CODES AS WELL NRTL: NATIONALLY RECOGNIZED TESTING LABORATORY, AS DEFINED AND LISTED BY ROOFS: ACCORDANCE WITH THE MANUFACTURERS' INSTRUCTIONS. 1550003152 AS MANUFACTURER'S REQUIREMENTS. THE MOST STRINGENT OSHA IN 29 CFR 1910.7 (E.G., UL, ETL, CSA), AND ACCEPTABLE TO THE AHJ OVER THIS 16A TRAINING COORDINATE ALL ROOF PENETRATIONS WITH ENGINEEROWNERAND AS PROVIDE GRS FOR ALL CONDUITS RUN EXPOSED TO WEATHER, OR EXPOSED TO , , PROJECT. BE RESPONSIBLE FOR CORRECT ROUGH-IN DIMENSIONS, AND VERIFY THEM WITH OTHER HAZARDOUS CONDITIONS. CRITERIA SHALL APPLY. ALL ANCHOR CONNECTIONS TO AT A TIME MUTUALLY AGREED UPON BETWEEN THE OWNER AND CONTRACTOR, APPLICABLE, THE ROOFING CONTRACTOR PROVIDING A ROOF WARRANTY. ENGINEER, OWNER'S REPRESENTATIVE, EQUIPMENT SUPPLIER, OR ALL THREE, STRUCTURE FOR SUPPORT OF MECHANICAL AND ELECTRICAL HOMERUN: THAT PORTION OF AN ELECTRICAL CIRCUIT ORIGINATING AT A JUNCTION PROVIDE THE SERVICES OF A FACTORY TRAINED AND AUTHORIZED PRIOR TO ROUGH-IN AND SERVICE INSTALLATIONS. ALL OTHER RACEWAY MAY BE EMT WHERE APPROVED BY LOCAL CODE. USE Job Name and Number EQUIPMENT, REGARDLESS OF THE NEED FOR SEISMIC BOX, TERMINATION BOX, RECEPTACLE OR SWITCH WITH TERMINATION AT AN REPRESENTATIVE TO TRAIN OWNER'S DESIGNATED PERSONNEL ON THE OPERATION KEEP ALL RACEWAY PENETRATIONS WITHIN MECHANICAL EQUIPMENT CURBS COMPRESSION TYPE FITTINGS FOR EMT, WITH ALL FITTINGS UL LISTED FOR THE 2015-0131 WHEREVER POSSIBLE. COORDINATE WITH DIVISION 15 WORK. ELECTRICAL PANELBOARD. NOTE: WHERE MC CABLE IS UTILIZED FOR RECEPTACLE AND MAINTENANCE OF THEPROJECT. 16A CLEANING WHICH THEY ARE USED. RESTRAINTS, SHALL BE SHOWN ON SHOP DRAWINGS. EQUIPMENT PROVIDED FOR THISENVIRONMENT IN AND/OR LIGHTING BRANCH CIRCUITING LOADS, THE ORIGINATING POINT OF THE FLASH AND COUNTERFLASH ALL OPENINGS THROUGH ROOF, AND/OR PROVIDE PRE- Proposed HOMERUN SHALL BE AT THE FIRST LOAD IN THE CIRCUIT OR AT A JUNCTION BOX IN PROVIDE TRAINING TO INCLUDE BUT NOT BE LIMITED TO AN OVERVIEW OF THE FABRICATED MOLDED SEALS COMPATIBLE WITH THE ROOF CONSTRUCTION IN ADDITION TO THE REQUIREMENTS OF DIVISION 1, REMOVE FROM THE PREMISES UNDERGROUND USE p AN ACCESSIBLE CEILING SPACE IMMEDIATELY ABOVE THE FIRST LOAD. SYSTEM AND/OR EQUIPMENT AS IT RELATES TO THE FACILITY AS A WHOLE; DIRT AND REFUSE RESULTING FROM THE PERFORMANCE OF THE ELECTRICAL OR ROOFING OWNER OR AS REQUIRED BY THE ENGINEER, , OPERATION AND MAINTENANCE PROCEDURES AND SCHEDULES RELATED TO INSTALLED,CONTRACTOR. ALL ROOF PENETRATIONS SHALL BE LEAKTIGHT AT THE WORK, AS REQUIRED, TO PREVENT ACCUMULATION. COOPERATE IN MAINTAINING PROVIDE GRS INSTALLED BELOW GRADE WITH A CORROSION RESISTANT BONDED- V E R I ZO N THE TERMS 'APPROVED EQUAL", "EQUIVALENT', OR "EQUAL" ARE USED STARTUP AND SHUTDOWN, TROUBLESHOOTING, SERVICING, PREVENTIVE REASONABLY CLEAN PREMISES AT ALL TIMES. IMMEDIATELY PRIOR TO FINAL PLASTIC OR APPROVED MASTIC COATING. THIS SHALL INCLUDE THE 90-DEGREE SYNONYMOUSLY AND SHALL MEAN "ACCEPTED BY OR ACCEPTABLE TO THE MAINTENANCE AND APPROPRIATE OPERATOR INTERVENTION; AND REVIEW OF DATA TERMINATION OF THE WORK AND SHALL NOT VOID ANY NEW OR EXISTING ROOF INSPECTION, MAKE A FINAL CLEANUP OF DIRT AND REFUSE RESULTING FROM THE ELBOW BELOW GRADE AND THE ENTIRE VERTICAL TRANSITION TO ABOVE GRADE. ENGINEER AS EQUIVALENT TO THE ITEM OR MANUFACTURER SPECIFIED". THE TERM INCLUDED IN THE OPERATION AND MAINTENANCE INSTRUCTIONS. WARRANTIES. WORK. CLEAN ALL MATERIAL AND EQUIPMENT INSTALLED UNDER THIS DIVISION. "APPROVED" SHALL MEAN LABELED, LISTED, CERTIFIED, OR ALL THREE, BY AN NRTL, WALLS AND FLOORS: REMOVE DIRT, DUST, PLASTER, STAINS AND FOREIGN MATTER FROM ALL SURFACES. RNC CONDUIT MAY BE USED UNDERGROUND WHERE PERMITTED BY LOCAL CODE STORE AND ACCEPTABLE TO THE AHJ OVER THIS PROJECT. SUBMIT A CERTIFICATION LETTER TO THE ARCHITECT STATING THAT THE OWNER'S TOUCH UP AND RESTORE ALL DAMAGED FINISHES TO THEIR ORIGINAL CONDITION. AND WHERE NOT SPECIFICALLY RESTRICTED BY THESE DOCUMENTS. WHEN USED, DESIGNATED REPRESENTATIVE HAS BEEN TRAINED AS SPECIFIED HEREIN. LETTER PROVIDE COATED GRS, AS SPECIFIED ABOVE, FOR ALL BENDS GREATER THAN 30 VISIT SHALL INCLUDE DATE 16A PRE-BID , TIME, ATTENDEES AND SUBJECT OF TRAINING. THE SLEEVES FOR RACEWAYS AND CABLES 16A ADJUSTING. ALIGNING AND TESTING DEGREES, INCLUDING THE 90D (LEED) SITE SI 90-DEGREE ELBOWS BELOW GRADE AND THE ENTIRE CONTRACTOR AND THE OWNER'S REPRESENTATIVE SHALL SIGN THE CERTIFICATION 1. STEEL PIPE SLEEVES: ASTM A 53/A 53M, TYPE E, GRADE B, SCHEDULE 40, VERTICAL RISERS FOR TRANSITIONS FROM BELOW TO ABOVE GRADE OR ABOVE- PERSONALLY INSPECT THE SITE OF THE PROPOSED WORK AND BECOME FULLY LETTER INDICATING AGREEMENT THAT THE TRAINING HAS BEEN PROVIDED. GALVANIZED STEEL, PLAIN ENDS AND DRIP RINGS. ADJUST, ALIGN, AND TEST ALL ELECTRICAL EQUIPMENT ON THIS PROJECT PROVIDED SLAB. INFORMED OF CONDITIONS UNDER WHICH THE WORK IS TO BE DONE. FAILURE TO UNDER THIS DIVISION AND ALL ELECTRICAL EQUIPMENT FURNISHED BY OTHERS FOR DO SO WILL NOT BE CONSIDERED SUFFICIENT JUSTIFICATION TO REQUEST OR SCHEDULE TRAINING WITH OWNER WITH AT LEAST 7 DAYS' ADVANCE NOTICE. 2. CAST-IRON PIPE SLEEVES: CAST OR FABRICATED "WALL PIPE," EQUIVALENT TO INSTALLATION OR WIRING UNDER THIS DIVISION, FOR PROPER OPERATION. EQUIPMENT CONNECTIONS OBTAIN EXTRA COMPENSATION OVER AND ABOVE THE CONTRACT PRICE. DUCTILE-IRON PRESSURE PIPE, WITH PLAIN ENDS AND INTEGRAL WATERSTOP, USE FMC FOR FINAL CONNECTION TO EACH MOTOR AND TRANSFORMER, AND TO 16A WARRANTIES UNLESS OTHERWISE INDICATED. TEST ALL SYSTEMS AND EQUIPMENT ACCORDING TO THE REQUIREMENTS IN NETA ANY DEVICE THAT WOULD OTHERWISE TRANSMIT MOTION, VIBRATION, OR NOISE. 16A MATERIAL AND WORKMANSHIP ATS (LATEST EDITION) AND ALL ADDITIONAL REQUIREMENTS SPECIFIED IN USE LFMC WHERE EXPOSED TO LIQUIDS, VAPORS OR SUNLIGHT, AND TO CONNECT WARRANT EACH SYSTEM AND EACH ELEMENT THEREOF AGAINST ALL DEFECTS DUE SLEEVES FOR RECTANGULAR OPENINGS: GALVANIZED SHEET STEEL WITH MINIMUM FOLLOWING SECTIONS. TO KITCHEN AND FOOD SERVICE EQUIPMENT. PROVIDE ALL FMC AND LFMC WITH AN PROVIDE ALL MATERIAL AND EQUIPMENT NEW AND IN FIRST CLASS CONDITION. TO FAULTY WORKMANSHIP, DESIGN OR MATERIAL FOR A PERIOD OF 12 MONTHS 0.138 INCH THICKNESS AND OF WIDTH AND LENGTH TO SUIT APPLICATION. INSULATED BONDING CONDUCTOR. JobAddress PROVIDE MARKINGS OR A NAMEPLATE FOR ALL MATERIAL AND EQUIPMENT FROM DATE OF SUBSTANTIAL COMPLETION, UNLESS SPECIFIC ITEMS ARE NOTED TO MAINTAIN THE FOLLOWING ON THE PROJECT PREMISES AT ALL TIMES: A TRUE RMS IDENTIFYING THE MANUFACTURER AND PROVIDING SUFFICIENT REFERENCE TO CARRY A LONGER WARRANTY IN THE CONSTRUCTION DOCUMENTS OR READING VOLTMETER, A TRUE RMS READING AMMETER, AND A MEGOHMMETER USE ONLY METAL RACEWAYS FOR ALL POWER WIRING FROM THE OUTPUT OF Washington Square Mall ESTABLISH QUALITY, SIZE AND CAPACITY. ALL WORKMANSHIP SHALL BE OF THE MANUFACTURER'S STANDARD WARRANTY EXCEEDS 12 MONTHS. REMEDY ALL 16A SEISMIC CONTROLS FOR MEPF SYSTEMS INSULATION RESISTANCE TESTER. PROVIDE TEST DATA READINGS AS REQUESTED VARIABLE FREQUENCY DRIVES TO THEIR RESPECTIVE MOTORS. FINEST POSSIBLE BY EXPERIENCED MECHANICS OF THE PROPER TRADE. IN DEFECTS, OCCURRING WITHIN THE WARRANTY PERIOD(S), AS STATED IN THE SEISMIC PROTECTION CRITERIA: OR AS REQUIRED BY THE ENGINEER. 9585 S.W. Washington GENERAL, PROVIDE THE FOLLOWING QUALITY GRADE(S) FOR ALL MATERIALS AND GENERAL CONDITIONS AND DIVISION 1. RISK/OCCUPANCY CATEGORY: I, II or III GENERAL RACEWAY INSTALLATION REQUIREMENTS Square Roan EQUIPMENT SITE SOIL CATEGORY: CONTRACTOR'S SEISMIC ENGINEER TO DETERMINE 16A EQUIPMENT IDENTIFICATION INSTALL RACEWAYS PARALLEL AND PERPENDICULAR TO BUILDING LINES. u POI`Ianl� ALSO WARRANT THE FOLLOWING ADDITIONAL ITEMS: O COMMERCIAL SPECIFICATION GRADE SEISMIC DESIGN CATEGORY: CONTRACTOR'S SEISMIC ENGINEER TO DETERMINE PROVIDE EQUIPMENT IDENTIFICATION NAMEPLATES: INSTALL RACEWAYS TO REQUIREMENTS OF STRUCTURE AND TO REQUIREMENTS OF , OR 97223 ALL RACEWAYS ARE FREE FROM OBSTRUCTIONS, HOLES, CRUSHING, OR ALL OTHER WORK ON THE PROJECT; TO CLEAR ALL OPENINGS, DEPRESSIONS, q Space R05-R07 PROVIDE ALL HOISTS, SCAFFOLDS, STAGING, RUNWAYS, TOOLS, MACHINERY AND BREAKS OF ANY NATURE. COMPONENT IMPORTANCE FACTOR: DETERMINED FROM ASCE 7-2010 ON ALL PANELBOARDS, SWITCHES, STARTERS, DIMMERS, SWITCHES IN PIPES, DUCTS, REINFORCING STEEL, AND OTHER IMMOVABLE OBSTACLES. w EQUIPMENT REQUIRED FOR THE PERFORMANCE OF THE ELECTRICAL WORK. STORE DISTRIBUTION PANELBOARDS AND SWITCHBOARDS. n, AND MAINTAIN MATERIAL AND EQUIPMENT IN CLEAN CONDITION, AND PROTECTED ALL RACEWAY SEALS ARE EFFECTIVE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE REQUIREMENTS INSTALL RACEWAYS SET IN FORMS FOR CONCRETE STRUCTURE IN SUCH A MANNER FROM WEATHER, MOISTURE, AND PHYSICAL DAMAGE. FOR SEISMIC BRACING OF MECHANICAL, ELECTRICAL, AND PLUMBING SYSTEMS. WHERE INDICATED ON THE DRAWINGS. THAT INSTALLATION WILL NOT AFFECT THE STRENGTH OF THE STRUCTURE. r i THE ENTIRE ELECTRICAL SYSTEM IS FREE FROM ALL SHORT CIRCUITS AND SEISMIC PROTECTION CRITERIA USED TO DETERMINE SEISMIC BRACING txawle O FURNISH ONLY MATERIAL AND EQUIPMENT THAT ARE LISTED, LABELED, CERTIFIED, UNWANTED OPEN CIRCUITS AND GROUNDS. REQUIREMENTS OF ALL MECHANICAL, ELECTRICAL AND PLUMBING SYSTEMS SHALL NAMEPLATES: EXCEPT WHERE APPROVED IN WRITING BY THE ENGINEER, INSTALL NO RACEWAY IN ELECTRICAL cp OR ALL THREE, BY A NATIONALLY RECOGNIZED TESTING LABORATORY (NRTL), BE DETERMINED BY THE APPLICABLE CODE ADOPTED IN THE PROJECT A SLAB-ON-GRADE. LOCATE RACEWAY BELOW GRANULAR FILL BELOW SLABS-ON- m � WHENEVER ANY LISTING OR LABELING EXISTS FOR THE TYPES OF MATERIAL AND THE ABOVE WARRANTIES SHALL INCLUDE LABOR AND MATERIAL. MAKE REPAIRS OR JURISDICTION. WHERE NOT ALREADY DETERMINED WITHIN THE CONTRACT ENGRAVED, CONTRASTING COLOR, THREE-LAYER, LAMINATED PLASTIC GRADE. EQUIPMENT SPECIFIED. REPLACEMENTS WITHOUT ANY ADDITIONAL COSTS TO THE OWNER. DOCUMENTS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTRACTING A INDICATING THE NAME OF THE EQUIPMENT, LOAD, OR CIRCUIT AS DESIGNATED SPECIFICATIONS 2 LICENSED PROFESSIONAL ENGINEER TO ESTABLISH BUILDING SITE CLASS, SEISMIC ON THE DRAWINGS AND IN THE SPECIFICATIONS: INSTALL RACEWAYS CONTINUOUS BETWEEN CONNECTIONS TO OUTLETS, BOXES ca 2 w AT A MINIMUM, GENERAL WORK PRACTICES FOR ELECTRICAL CONSTRUCTION SHALL PERFORM THE REMEDIAL WORK PROMPTLY, UPON WRITTEN NOTICE FROM THE DESIGN CATEGORY, SEISMIC ZONE OR ANY OTHER CRITERIA NECESSARY TO AND CABINETS WITH A MINIMUM POSSIBLE NUMBER OF BENDS AND NOT MORE THAN BE IN ACCORDANCE WITH: ENGINEER OR OWNER. DETERMINE THE REQUIREMENTS FOR SEISMIC BRACING ON MECHANICAL, SELF-ADHERING, WITH A PERMANENT, WEATHERPROOF ADHESIVE. THE EQUIVALENT OF FOUR 90-DEGREE BENDS BETWEEN CONNECTIONS. USE % NECA 1 (LATEST EDITION), "STANDARD PRACTICES FOR GOOD ELECTRICAL AND/OR PLUMBING SYSTEMS. MANUFACTURED ELBOWS FOR ALL 45- AND 90-DEGREE BENDS, UNLESS APPROVED oo WORKMANSHIP IN ELECTRICAL CONSTRUCTION'. AT THE TIME OF SUBSTANTIAL COMPLETION, DELIVER TO THE OWNER ALL ATTACHMENT METHOD SHALL BE ACCEPTABLE TO THE MANUFACTURERS OF THE BY THE ENGINEER IN ADVANCE. MAKE OTHER BENDS SMOOTH AND EVEN AND O WARRANTIES, IN WRITING AND PROPERLY EXECUTED, INCLUDING TERM LIMITS FOR SEISMIC BRACING OF FIRE PROTECTION SYSTEMS SHALL BE INSTALLED IN STRICT EQUIPMENT TO WHICH THE NAMEPLATES ARE BEING APPLIED. WITHOUT FLATTENING RACEWAY OR FLAKING GALVANIZING OR ENAMEL. RADII OF 4M'2 11-1 16A MANUFACTURERS WARRANTIES EXTENDING BEYOND THE ONE YEAR PERIOD, EACH WARRANTY ACCORDANCE WITH THE PROVISIONS OF NFPA 13 (2010 OR LATER EDITION). BENDS SHALL BE AS LONG AS POSSIBLE AND NEVER SHORTER THAN THE r' p INSTRUMENT BEING ADDRESSED TO THE OWNER AND STATING THE COLOR: BLACK BACKGROUND WITH WHITE LETTERS FOR NORMAL POWER; 1/4- CORRESPONDING TRADE ELBOW. IN OTHER ARTICLES WHERE LISTS OF MANUFACTURERS ARE INTRODUCED, SUBJECT COMMENCEMENT DATE AND TERM. THE CONTRACTOR SHALL DETERMINE THE TYPE AND LOCATION OF SEISMIC INCH MINIMUM. Drawn By: North m 1 TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE BRACING REQUIRED FOR THE MECHANICAL ELECTRICAL AND PLUMBING ELEMENTS USE LONG RADIUS ELBOWS FOR ALL UNDERGROUND INSTALLATIONS, WHERE LKV ` 0 o MANUFACTURERS SPECIFIED. 16A MISCELLANEOUS REMODELING WORK SHOWN ON THE DRAWINGS BASED ON THE ESTABLISHED SEISMIC CRITERIA, THE 16A SYSTEM START UP NECESSARY OR INDICATED. C Q SIZE AND WEIGHT OF THE SUPPORTED ELEMENT AND THE DISTANCE FROM Checked By: !' O WHERE A LIST IS PROVIDED, MANUFACTURERS ARE LISTED ALPHABETICALLY AND PROVIDE ALL DEMOLITION OF EXISTING ELECTRICAL SYSTEMS AND NEW STRUCTURE OF THE SUPPORTED ELEMENT. PRIOR TO STARTING UP THE ELECTRICAL SYSTEMS: SECURELY FASTEN RACEWAYS IN PLACE WITH APPROVED STRAPS, HANGERS AND AJO 0 �_ NOT IN ACCORDANCE WITH ANY RANKING OR PREFERENCE. ELECTRICAL SYSTEM MODIFICATIONS REQUIRED BECAUSE OF BUILDING STEEL SUPPORTS AS REQUIRED. ATTACH RACEWAY SUPPORTS TO THE BUILDING 0 1 REMODELING, AS NOTED ON THE DRAWINGS, OR NECESSARY FOR PROPER THE CONTRACTOR SHALL SUBMIT THE FOLLOWING SHOP DRAWING INFORMATION 1. CHECK ALL COMPONENTS AND DEVICES. STRUCTURE. HANG SINGLE RACEWAYS FOR FEEDERS WITH MALLEABLE SPLIT RING DatelssuedFor a WHERE MANUFACTURERS ARE NOT LISTED, PROVIDE PRODUCTS SUBJECT TO OPERATION AND NEW CONSTRUCTION. REMOVE ALL ABANDONED CABLES AND TO THE AUTHORITY HAVING JURISDICTION AND THE ENGINEER OF RECORD FOR HANGERS WITH ROD AND TURNBUCKLE SUSPENSION FROM INSERTS SPACED NOT Client; i2f2442015 6 w COMPLIANCE WITH REQUIREMENTS FROM MANUFACTURERS THAT HAVE BEEN WIRING ABOVE ACCESSIBLE CEILINGS AND VENTILATION SHAFTS. REVIEW AND APPROVAL: 1 SEISMIC ANALYSIS LISTING ALL APPLICABLE SEISMIC 2. LUBRICATE ITEMS ACCORDINGLY. OVER 10 FEET APART IN CONSTRUCTION ABOVE. CLAMP GROUPS OF HORIZONTAL 3 re ( ) Landlord; i2L24/2015 Q ACTIVELY INVOLVED IN MANUFACTURING THE SPECIFIED PRODUCT FOR NO LESS DESIGN CRITERIA (2) DESCRIPTIVE CATALOG DATA OF SEISMIC BRACING MATERIALS, FEEDER RACEWAYS TO STEEL CHANNELS THAT ARE SUSPENDED FROM INSERTS 3. TIGHTEN SCREWS AND BOLTS FOR CONNECTORS AND TERMINALS ACCORDING TO w THAN 5 YEARS. 16A ELECTRICAL WORK (3) SHOP DRAWINGS SHOWING BRACING TYPE AND LOCATION, (4) INSTALLATION SPACED NOT OVER 10 FEET APART IN CONSTRUCTION ABOVE. SECURELY CLAMP Permit�2/24/2015 04 (li DETAILS OF ALL BRACING USED AND (5) CALCULATIONS SHOWING THAT THE SEISMIC MANUFACTURER'S PUBLISHED TORQUE-TIGHTENING VALUES. IF MANUFACTURER'S VERTICAL FEEDER RACEWAYS TO STRUCTURAL STEEL MEMBERS ATTACHED TO a Z 16A COORDINATION 16A BUILDING OPERATION RESTRAINTS MEET THE SEISMIC REQUIREMENTS. SHOP DRAWINGS AND TORQUE VALUES ARE NOT INDICATED, USE THOSE SPECIFIED IN UL 486A AND STRUCTURE. INSTALL CABLE CLAMPS FOR SUPPORT OF VERTICAL FEEDERS WHERE 81d. C, CALCULATIONS SHALL BE SIGNED AND SEALED BY A REGISTERED PROFESSIONAL UL 4866. REQUIRED. ADD RACEWAY SUPPORTS WITHIN 12 INCHES OF ALL BENDS, ON BOTH 0 o Construction: L- I LO N DO NOT SUPPORT RACEWAYS FROM SUSPENDED CEILING m O COORDINATE ALL WORK WITH OTHER DIVISIONS AND TRADES SO THAT VARIOUS COMPLY WITH THE SCHEDULE OF OPERATIONS AS OUTLINED IN THE ENGINEER, LICENSED IN THE STATE OF THE PROJECT AND EMPLOYED BY THE SIDES OF THE BENDS. Z COMPONENTS OF THE ELECTRICAL SYSTEMS ARE INSTALLED AT THE PROPER TIME, ARCHITECTURAL PORTIONS OF THIS SPECIFICATION. BUILDING SHALL BE IN MANUFACTURER OF THE SEISMIC BRACING PRODUCTS. CALCULATIONS SHALL 4. ADJUST TAPS ON EACH TRANSFORMER FOR RATED SECONDARY VOLTAGE WHEN COMPONENTS. Revsionlssue ai = FIT THE AVAILABLE SPACE, AND ALLOW PROPER SERVICE ACCESS TO ALL CONTINUOUS OPERATION. ACCOMPLISH WORK THAT REQUIRES INTERRUPTION OF INCLUDE DEAD LOADS, STATIC SEISMIC LOADS AND CAPACITY OF MATERIALS THE TRANSFORMER IS AT MINIMUM LOAD. Na. Date Desaftrilan w EQUIPMENT. REFER TO ALL DRAWINGS, INCLUDING, BUT NOT LIMITED TO, CIVIL, BUILDING OPERATION AT A TIME WHEN THE BUILDING IS NOT IN OPERATION, AND UTILIZED FOR CONNECTIONS. REAM RACEWAY ENDS, THOROUGHLY CLEAN RACEWAYS BEFORE INSTALLATION, 0 $ ARCHITECTURAL, STRUCTURAL, MECHANICAL, AND PLUMBING, AND TO RELEVANT ONLY WITH WRITTEN APPROVAL OF BUILDING OWNER AND/OR TENANT. 5. CHECK AND RECORD BUILDING'S SERVICE ENTRANCE VOLTAGE, GROUNDING AND KEEP CLEAN AFTER INSTALLATION. PLUG OR COVER OPENINGS AND BOXES AS o EQUIPMENT SUBMITTALS AND SHOP DRAWINGS TO DETERMINE THE EXTENT OF COORDINATE INTERRUPTION OF BUILDING OPERATION WITH THE OWNER AND/OR SEISMIC BRACING, RESTRAINTS, ISOLATORS, AND ISOLATION MATERIALS SHALL BE CONDITIONS, GROUNDING RESISTANCE, AND PROPER PHASING. REQUIRED TO KEEP RACEWAYS CLEAN DURING CONSTRUCTION AND FISH ALL W I CLEAR SPACES. MAKE ALL OFFSETS REQUIRED TO CLEAR EQUIPMENT, BEAMS AND TENANT A MINIMUM OF 7 DAYS IN ADVANCE OF WORK. OF THE SAME MANUFACTURER AND SHALL BE CERTIFIED BY THE MANUFACTURER. RACEWAYS CLEAR OF OBSTRUCTIONS BEFORE PULLING CONDUCTORS WIRES. OTHER STRUCTURAL MEMBERS, AND TO FACILITATE CONCEALING RACEWAYS IN APPROVED MANUFACTURERS ARE: AMBER/BOOTH COMPANY, INC., KINETICS NOISE 6. REPLACE ALL BURNED-OUT LAMPS AND LAMPS USED FOR TEMPORARY PROVIDE RACEWAYS OF AMPLE SIZE FOR PULLING OF WIRE AND NOT SMALLER m 0 THE MANNER ANTICIPATED IN THE DESIGN. PROVIDE MATERIALS WITH TRIM THAT 16A EXCAVATION AND BACKFILLING CONTROL, INC., LOOS & COMPANY, INC., MASON INDUSTRIES, INC., UNI-STRUT, CONSTRUCTION LIGHTING IN PERMANENT LIGHT FIXTURES. THAN CODE REQUIREMENTS AND NOT LESS THAN 1/2-INCH IN SIZE, UNLESS .2 WILL FIT PROPERLY THE TYPES OF CEILING, WALL, OR FLOOR FINISHES ACTUALLY VIBRO-ACOUSTICS, OR B-LINE/TOLCO. EACH DEVICE SHALL HAVE A PRE-APPROVAL INDICATED OTHERWISE ON DRAWINGS. HOMERUNS CONTAINING MORE THAN ONE a � INSTALLED. PERFORM EXCAVATION AND BACKFILL REQUIRED FOR INSTALLATION OF NUMBER FROM CALIFORNIA OSHPD OR OTHER RECOGNIZED GOVERNMENT AGENCY 7. BALANCE ALL SINGLE-PHASE LOADS AT EACH PANELBOARD, REDISTRIBUTING BRANCH CIRCUIT SHALL NOT BE LESS THAN 3/4- INCH IN SIZE. UNDERGROUND WORK UNDER THIS CONTRACT. TRENCHES SHALL BE OF SHOWING MAXIMUM RESTRAINT RATINGS. BRANCH CIRCUIT CONNECTIONS UNTIL BALANCE IS ACHIEVED. DO NOT TYPE UP M 16A ORDINANCES. CODES. AND STANDARDS SUFFICIENT WIDTH. CRIB OR BRACE TRENCHES TO PREVENT CAVE-IN OR FINAL PANELBOARD DIRECTORIES UNTIL ALL RE-BALANCING AND REDISTRIBUTION PROTECT ALL RACEWAY INSTALLATIONS AGAINST DAMAGE DURING CONSTRUCTION. C, p SETTLEMENT. DO NOT EXCAVATE TRENCHES CLOSE TO COLUMNS AND WALLS OF SEISMIC BRACING MEASURES TO BE APPLIED TO OF CIRCUITS ARE COMPLETE. TURN ON ALL LOADS IN AN ATTEMPT TO MAXIMIZE THE REPAIR ALL RACEWAYS DAMAGED OR MOVED OUT OF LINE AFTER ROUGHING-IN TO o 0 COMPLY, AT A MINIMUM, WITH NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) NEW BUILDING WITHOUT PRIOR CONSULTATION WITH THE ENGINEER. USE PUMPING MECHANICAL/ELECTRICAL/PLUMBING EQUIPMENT AND SYSTEMS SHALL BE LOAD ON THE PANEL AND TAKE AMPERE READINGS ON EACH OF THE PHASES MEET ENGINEER'S APPROVAL WITHOUT ADDITIONAL COST TO THE OWNER. rn BEFORE REDISTRUBITNG CIRCUITS AND BALANCING THE PANEL. r to STANDARDS, STATE AND LOCAL BUILDING CODES, AND ALL OTHER APPLICABLE EQUIPMENT IF REQUIRED TO KEEP TRENCHES FREE OF WATER. BACKFILL INSTALLED IN STRICT ACCORDANCE WITH ALL APPLICABLE LOCAL, STATE, AND/OR r CODES AND ORDINANCES FOR PERFORMANCE, WORKMANSHIP, EQUIPMENT, AND TRENCHES IN MAXIMUM 6-INCH LAYERS OF WELL TAMPED DRY EARTH IN A MANNER FEDERAL CODES AS WELL AS MANUFACTURER'S REQUIREMENTS. THE MOST ALIGN AND INSTALL TRUE AND PLUMB ALL RACEWAY TERMINATIONS AT m Z MATERIALS. ADDITIONALLY, COMPLY WITH RULES AND REGULATIONS OF PUBLIC TO PREVENT FUTURE SETTLEMENT. STRINGENT CRITERIA SHALL APPLY. ALL ANCHOR CONNECTIONS TO STRUCTURE 8. AFTER ALL SYSTEMS HAVE BEEN INSPECTED AND ADJUSTED, CONFIRM ALL PANELBOARDS, SWITCHBOARDS, MOTOR CONTROL EQUIPMENT AND JUNCTION �- O UTILITIES AND MUNICIPAL DEPARTMENTS AFFECTED BY CONNECTION OF SERVICES. FOR SUPPORT OF MECHANICAL AND ELECTRICAL EQUIPMENT, REGARDLESS OF THE OPERATING FEATURES REQUIRED BY THE DRAWINGS AND SPECIFICATIONS AND BOXES. _N N-N, NEED FOR SEISMIC RESTRAINTS, SHALL BE SHOWN ON SHOP DRAWINGS. MAKE FINAL ADJUSTMENTS AS NECESSARY. > > N o I C M 11-1 LO rn N : DrawingNumber: = O N J a C.,--,g £m �' Q o O wZ E6 J d 0 ", zi 28 OF 31 J_ =i % I 16B WIRING DEVICES GRUSKIN THE CATALOG NUMBERS LISTED FOR WIRING DEVICES ARE GENERALLY FOR 20A INSTALL APPROVED EXPANSION/DEFLECTION FITTINGS WHERE RACEWAYS PASS SYSTEM VOLTAGE RATED DEVICES. WHERE 15A RATED DEVICES ARE INDICATED ON THE DRAWINGS WHERE INDICATED, PROVIDE FUSIBLE SWITCHES PERMANENTLY LABELED AS PACKAGING OF LIGHT FIXTURES WILL NOT BE ALLOWED. ONLY THOSE LUMINAIRES 16B WIRING OF THERMOSTATS. TIME AND TEMPERATURE CONTROLS THROUGH (IF EMBEDDED) OR ACROSS (IF EXPOSED) EXPANSION JOINTS. ALSO OR REQUIRED FOR CIRCUIT RATING LIMITATIONS, PROVIDE WIRING DEVICES SUITABLE FOR USE AS SERVICE ENTRANCE EQUIPMENT, WITH INTEGRAL AND LISTED IN THE LIGHT FIXTURE SCHEDULE, OR APPROVED IN ACCORDANCE WITH 294 Morris Avenue Springfield,NJ 070$1 WHEN USING RNC OR RAC IN EXPOSED ENVIRONMENTS IN ACCORDANCE WITH THE SystEQUIVALENT TO THOSE SPECIFIED FOR 20A, BUT RATED FOR 15A. SEPARATE NEUTRAL AND GROUND ASSEMBLIES, SUITABLE FOR THE SIZES OF SUBSTITUTIONS OF THESE SPECIFICATIONS, WILL BE ACCEPTED. WHERE THE LIGHT PROVIDE ALL RACEWAYS, POWER WIRING, AND LINE—VOLTAGE CONTROL AND Tel: 973.376.441 1 Fax:973.376.8989 NEC AND EXPANSION/CONTRACTION PROPERTIES OF RNC OR RAC. Arlt Voltage Conducfior T Color CONDUCTORS INDICATED. DO NOT DOUBLE—LUG ANY TERMINATIONS NOT FIXTURE SCHEDULE INDICATES AN ALLOWANCE FOR A SPECIFIC LIGHT FIXTURE, THE INTERLOCK WIRING NOT PROVIDED UNDER DIVISION 15, FOR ALL THERMOSTATS, www.GruskinGroup.com NJ REG 0100-9869-14 208Y/120 Phase A Black ALL RECEPTACLES LOCATED OUTDOORS OR IN DAMP OR WET LOCATIONS: SHALL BE SPECIFICALLY LISTED AS SUITABLE FOR MORE THAN ONE CONDUCTOR. PRICE IS A CONTRACTOR PRICE. INCLUDE ALL ADDITIONAL COSTS FOR FREIGHT, TEMPERATURE CONTROL DEVICES, AND CONTROLS, INCLUDING, BUT NOT LIMITED INSTALL A PULL WIRE IN EACH EMPTY RACEWAY THAT IS LEFT FOR INSTALLATION OF Phase B Red LISTED AS 'WEATHER RESISTANT', DESIGNATED BY A 'WR' ON THE FACEPLATE. LAMPS, AND INSTALLATION OF LIGHT FIXTURE AND LAMPS. TO, NIGHT—STATS, WATER HEATER INTERLOCKS, TIME SWITCHES AND OVERRIDE Thisdocument and the ideas and designs incorporated CONDUCTORS OR CABLES UNDER OTHER DIVISIONS OR CONTRACTS. USE Phase C Blue PROVIDE SWITCHES WHERE NOT FURNISHED WITH THE STARTING EQUIPMENT, AT TIMERS. SEE MECHANICAL DRAWINGS FOR LOCATIONS AND TEMPERATURE POLYPROPYLENE OR MONOFILAMENT PLASTIC LINE WITH NOT LESS THAN 200—LB PROVIDE THE FOLLOWING WIRING DEVICES WHERE SHOWN ON DRAWINGS OR ALL OTHER POINTS REQUIRED BY NFPA 70, AND WHERE INDICATED ON THE INSTALL FLUORESCENT LIGHT FIXTURES HUNG IN CONTINUOUS ROWS ON CHANNEL CONTROL DIAGRAMS. LOW—VOLTAGE CONDUCTORS FOR THERMOSTATS AND proper, c an Instrument of professional service Is the Neutral White TENSILE STRENGTH. LEAVE AT LEAST 24 INCHES OF SLACK AT EACH END OF PULL REQUIRED. MINOR CHANGES RELATIVE TO THE LOCATION OF ELECTRICAL DRAWINGS. STRUTS SPECIFICALLY DESIGNED FOR THIS PURPOSE. TEMPERATURE CONTROL SYSTEM MAY BE RUN EXPOSED ABOVE FINISHED propertyof GRUSKIN ARCHfIECTURE+DESIGN,P.C.,and WIRE. Equipment Ground Green EQUIPMENT MAY BE MADE TO COMPLY WITH STRUCTURAL AND BUILDING ACCESSIBLE CEILINGS, IF APPROVED AND LISTED FOR THIS PURPOSE, BUT SHALL BE is not to be used in whole or in part for any other project Isolated Ground Green w/yellow stripe REQUIREMENTS AS DETERMINED IN THE COURSE OF CONSTRUCTION. PROVIDE ALL 16B FUSES SURFACE—MOUNT ALL FLUORESCENT LIGHT FIXTURES LOCATED IN AREAS WITH A INSTALLED IN CONDUIT WITHIN WALLS AND WHERE EXPOSED IN THE WORK AREAS. without the written authorization of GRUSKIN MAKE ALL JOINTS AND CONNECTIONS IN A MANNER THAT WILL ENSURE MECHANICAL WIRING DEVICES OF THE SAME MANUFACTURER AND NOT MIXED ON THE PROJECT, CEILING BUT WITHOUT SUSPENDED CEILINGS UNLESS OTHERWISE INDICATED ON ARCHITECTURE+DESIGN,P.C. STRENGTH AND ELECTRICAL CONTINUITY. TO THE MAXIMUM EXTENT POSSIBLE. PROVIDE COLOR OF TOGGLES AND PROVIDE EACH CIRCUIT AND SET OF FUSE CLIPS THROUGHOUT THE WORK WITH THE DRAWINGS. PROVIDE RIGID METAL SPACERS FINISHED IN WHITE ENAMEL 16B TELEPHONE SYSTEM PROVISIONS All Rot9Reserved 480Y/277 Phase A Brown RECEPTACLES AS REQUESTED BY THE ENGINEER: REFER TO DETAIL SHOWING BUSSMANN, FERRAZ SHAWMUT, OR LITTLEFUSE FUSES, SIZES AND TYPES AS BETWEEN THE TOP OF EACH LIGHT FIXTURE AND THE CEILING ABOVE TO MAINTAIN A 166 BUSHINGS AND LOCKNUTS Phase B Orange RECEPTACLES TABLE. REQUIRED OR INDICATED. ALL FUSES LARGER THAN 60OA: UL CLASS L, SIMILAR TO 1-1/2—INCH SPACE. SPACERS SHALL BE APPROVED BEFORE INSTALLATION. PROVIDE INCOMING TELEPHONE SERVICE RACEWAYS AS INDICATED ON DRAWINGS ©2015GrttskinArchitecture+Design,P.C. Phase C Yellow TYPE KRP—C BUSSMANN LOW PEAK OR EQUAL. FUSES USED TO PROTECT MOTORS: OR AS REQUIRED BY THE SERVING TELEPHONE COMPANY. PROVIDE 3/4—INCH THICK K�fh A. all�kh AIA RIGIDLY TERMINATE CONDUITS ENTERING SHEET METAL ENCLOSURES TO THE Neutral Gray UL CLASS RK5, BUSSMANN FUSETRON OR EQUAL. FUSES USED TO PROTECT ALL INSTALL ALL FLUORESCENT LIGHT FIXTURES LOCATED IN AREAS WITHOUT CEILINGS PLYWOOD BOARD, FIRE—RETARDANT—TREATED AND STAMPED FRT, SECURELY ENCLOSURE WITH A BUSHING AND LCON UI ON THE INSIDE AND A LOSURE OR AN of IloOm Hubbell Pap Ar Loffon p Coopw �� OTHER ELECTRICAL EQUIPMENT: UL CLASS RK1, DUAL ELEMENT, BUSSMANN IMMEDIATELY BELOW THE ROOF—FRAMING MEMBERS, OR SUSPENDED FROM CHAIN ANCHORED TO THE WALL, AT THE LOCATION AND OF THE SIZE AS INDICATED ON THE Equipment Ground Green APPROVED HUB ON THE OUTSIDE. CONDUIT SHALL ENTER THE ENCLOSURE LPS/LPN OR EQUAL. ALL FUSED DEVICES SHALL BE LABELED AS TO TYPE AND SIZE HANGERS SUITABLE IN LENGTH TO PROVIDE THE INDICATED MOUNTING HEIGHT. DRAWINGS. PROVIDE FLUSH MOUNTED TELEPHONE OUTLET BOXES WITH 1—INCH AL 5421 MT 2537 SQUARELY. Simplex Receptacle HBL 5361 5361 5891 5,351 OF FUSE REQUIRED. HANGERS: "HYDEE" HANGER TYPE FOR OUTLET BOX MOUNTING, COMPLETE WITH EMT STUB—UP CONCEALED TO ACCESSIBLE CEILING SPACE AT LOCATIONS AS AK 13167 NC 9961 Duplex Receptacle CR5352 5352 5352 5352 GROUNDING RECEPTACLE, PLUG, 3—WIRE CORD AND NECESSARY CHAIN. INDICATED ON THE DRAWINGS. AR 3811 ND 1666 PROVIDE BUSHINGS AND LOCKNUTS MADE OF GALVANIZED MALLEABLE IRON WITH USE OF MC CABLE Red Duplex Receptacle 5362—R 23642—RED 5352 5352 FURNISH THREE SPARE FUSES OF EACH SIZE AND TYPE USED ON THE PROJECT AZ 39209 NE A-3547 SHARP, CLEAN—CUT THREADS. MAY ONLY BE USED: GFCI Receptacle GF5352 2091 6898 6598 XGF20 (EXCEPT FOR MAIN SWITCH FUSES, FURNISH ONE SPARE), NEATLY CONTAINED IN A THROUGH WIRING OF RECESSED LIGHT FIXTURES, IN SUSPENDED CEILINGS, IS NOT 16B DATA SYSTEM PROVISIONS CA C-29698 NH 2796 Safety Receptacle HBL830OSG TR63 8300—SC TR 8300 PROPERLY LABELED CABINET. PERMITTED. CONNECT EACH LIGHT FIXTURE BY A WHIP TO A JUNCTION BOX. WHERE EMT ENTERS A 80X, PROVIDE APPROVED EMT COMPRESSION CONNECTORS. IN LIEU OF FLEXIBLE CONDUIT AND WIRING FROM LIGHT FIXTURES IN 20A 125V PROVIDE CABLE WHIPS OF SUFFICIENT LENGTHS TO ALLOW FOR RELOCATING EACH PROVIDE FLUSH MOUNTED DATA OUTLET BOXES WITH 1—INCH CONDUIT STUB—UP CO ARC-400347 NJ Al 09999 ACCESSIBLE CEILINGS TO JUNCTION BOXES (ATTACHED TO BUILDING WR GFCI Receptacle GFR5362—TR 2095 TRWR W7899—T TWRVG 20 166 DRY—TYPE TRANSFORMERS LIGHT FIXTURE WITHIN A 5—FOOT RADIUS OF ITS INSTALLED LOCATION, BUT NOT CONCEALED TO ACCESSIBLE CEILING SPACE AT LOCATIONS AS INDICATED ON THE CT 9613 NM 004168 USE INSULATED, GROUNDING, OR COMBINATION, BUSHINGS WHEREVER STRUCTURE) ABOVE THE CEILING. PROVIDE CABLE WHIPS OF SUFFICIENT Quad 4—Plex HBL 420 420 21254 N/A EXCEEDING 6 FEET IN UNSUPPORTED LENGTHS. DRAWINGS. DC ARC100723 NV 5521 CONNECTION IS SUBJECT TO VIBRATION OR MOISTURE, WHEN REQUIRED BY NFPA LENGTHS TO ALLOW FOR RELOCATING EACH LIGHT FIXTURE WITHIN A 5—FOOT Single Pole Switch CS1221 PS 20 ACI 1221-2 2221 TRANSFORMERS: GENERAL PURPOSE, UL—LISTED/LABELED. COMPLY WITH NEMA ST— DE 0006261 NY 025528-1 NY 70, OR BOTH. RADIUS OF ITS INSTALLED LOCATION, BUT NOT EXCEEDING 6 FEET IN Double Pale Switch CS1222 PS 20AC2 1222-2 2222 020 STANDARDS. 16B EMERGENCY LIGHTING UNITS AND EXIT SIGNS 16B TIME SWITCHES FL AR91629 OK a4895 UNSUPPORTED LENGTHS. Three—way Switch CS1223 PS 20AC3 1223-2 2223 GA RA011075 OH 13761 166 CONDUCTORS AND CABLES Four—way Switch CS1224 PS 20AC4 1224-2 12224 INSULATION CLASS: FOR THREE PHASE TRANSFORMERS LESS THAN 15 KVA AND ALL DESCRIPTION: SELF—CONTAINED UNITS COMPLYING WITH UL 924. TIME SWITCHES: ELECTRONIC DIGITAL ASTRONOMICAL, TYPE AS INDICATED, WITH HI AR 11489 FOR 4899 FOR VERTICAL DROPS IN STUD WALLS. SINGLE PHASE — 185 DEGREES C, UL—COMPONENT—RECOGNIZED INSULATION MANUAL BYPASS SWITCH, NEMA ENCLOSURE SUITABLE FOR THE ENVIRONMENT IA 05713 PA RA-01532—B CONDUCTOR MATERIAL: SYSTEM WITH A MAXIMUM OF 115 DEGREE C RISE ABOVE A 40 DEGREE C AMBIENT INSTALLED; NUMBER AND TYPES OF CONTACTS, SEQUENCE, AND VOLTAGE AS ID AR-964459 PR 19965 IN LIEU OF EMT, ONLY FOR 15A AND 20A BRANCH CIRCUITS (WITH UP TO TEMPERATURE; FOR THREE PHASE TRANSFORMERS 15 KVA AND LARGER — 220 BATTERY: SEALED, MAINTENANCE—FREE, LEAD—ACID TYPE. THE BATTERIES SHALL BE INDICATED ON THE DRAWINGS, OR AS REQUIRED, BASED ON THE TIME SWITCH 166 SWITCH AND OUTLET COVER PLATES IL 001-019152 RI 2666 ANNEALED (SOFT) COPPER COMPLYING WITH ICER 5-95-658/NEMA WC70; FOUR (4) CONDUCTORS, NOT INCLUDING GROUND CONDUCTOR), AND ONLY DEGREES C, UL—COMPONENT—RECOGNIZED INSULATION SYSTEM WITH A MAXIMUM OF SUITABLE RATING AND CAPACITY TO SUPPLY AND MAINTAIN AT NOT LESS THAN FUNCTION AND THE NUMBER OF BRANCH CIRCUITS OR CONTACTORS CONTROLLED. IN DRY CONCEALED LOCATIONS ABOVE GRADE, EXCEPT WHERE SPECIFICALLY OF 150 DEGREE C RISE ABOVE A 40 DEGREE C AMBIENT TEMPERATURE. UL— 87 1/ 2 PERCENT OF THE NOMINAL BATTERY VOLTAGE FOR THE TOTAL LAMP LOAD PROVIDE WIRING TO PHOTOCELLS, CONTACTORS, RELAYS OR OTHER CONTROL IN AR10400066 SC 6834 CONDUCTOR INSULATION TYPES: 90—DEGREE C—RATED, TYPE THHN THWN-2 OR NOT PERMITTED BY NEPA 70. SWITCH AND OUTLET PLATES: SMOOTH NYLON; BY THE SAME MANUFACTURER AS ASSOCIATED WITH THE UNIT FOR A PERIOD OF AT LEAST 1 1 2 HOURS, OR THE UNIT KS 4674 SD 11532 / THE WIRING DEVICES, WHEREVER POSSIBLE. VERIFY DESIRED MATERIALS AND COMPONENT—RECOGNIZED INSULATION SYSTEM REPLACES THE UL1446 INSULATION / POINTS AS REQUIRED. MANUFACTURERS: INTERMATIC, PARAGON OR TORK. XHHW-2 COMPLYING WITH ICEA S-95-658/NEMA WC70. COLORS WITH ENGINEER BEFORE INSTALLATION. SWITCH PLATES IN UNFINISHED RATING SYSTEM THAT USED LETTERS. EQUIPMENT SHALL SUPPLY AND MAINTAIN NOT LESS THAN 60 PERCENT OF THE KY 5967 TN 101374 MC CABLE SHALL NOT BE USED FOR ANY USE NOT LISTED ABOVE. INITIAL EMERGENCY ILLUMINATION FOR A PERIOD OF AT LEAST 1 1/ 2 HOURS. 16B PHOTO CONTROL LA 5734 TX 17680 SIZES OF CONDUCTORS AND CABLES INDICATED OR SPECIFIED ARE IN AMERICAN EXAMPLES OF THOSE USES INCLUDE, BUT ARE NOT LIMITED TO: ROOMS AND SPACES: STAMPED STEEL, CADMIUM PLATED. INSTALL GROUPS OF SWITCHES UNDER ONE GANGED—PLATE, USUALLY HORIZONTALLY; OR, WHERE PHASES, VOLTAGES, AND SIZES: AS INDICATED ON THE DRAWINGS. ME ARC 2596 UT 5881356-0301 WIRE GAGE (AWG — BROWN AND SHARPE). REQUIRED BY DETAILS, VERTICALLY. SET ALL COVER PLATES PLUMB, PARALLEL, AND CHARGER: FULLY AUTOMATIC, SOLID—STATE TYPE WITH SEALED TRANSFER RELAY. THE PHOTO CONTROL SHALL: MD 11016 VT 2572 HOMERUNS TO PANELBOARDS. FINISHED FLUSH WITH THE WALL. SOUND LEVEL: NOT EXCEEDING 3 dBA LESS THAN NEMA STANDARDS FOR THE SIZES MA 10635 VA 0401 011223 ALL FEEDER AND BRANCH CIRCUIT CONDUCTORS NO. 8 AWG AND LARGER: WHERE EXPOSED TO VIEW. INDICATED. OPERATION: RELAY AUTOMATICALLY TURNS LAMP ON WHEN POWER SUPPLY PROVIDE AUTOMATIC SWITCHING FOR LIGHTING LOADS USING A THERMAL DESIGN MI 1301052379 WA 10344 STRANDED. WHERE EXPOSED TO DAMAGE. CIRCUIT VOLTAGE DROPS TO 80 PERCENT OF NOMINAL VOLTAGE OR BELOW. LAMP N DELAY TO ENSURE THAT THE CONTROLLED LIGHTING DOES NOT 166 WEATHERPROOF COVER PLATES WITH BUILT—IN MN 44326 WI 9900-005 AUTOMATICALLY HAZARDOUS LOCATIONS. FULL—CAPACITY PRIMARY TAPS: BELOW 25 KVA —ONE 5 PERCENT TAP ABOVE AND AUT OM DISCONNECTS FROM BATTERY WHEN VOLTAGE APPROACHES SWITCH OFF DUE TO AMBIENT LIGHT OR LIGHTNING STRIKING THE PHOTOCELL. MO A-2005029740 WV 3727 ALL CONDUCTORS, NO. 10 AWG AND SMALLER: SOLID COPPER WET LOCATIONS. PROVIDE GFCI RECEPTACLES FOR DESIGNATED WEATHERPROOF RECEPTACLES, ONE 5 PERCENT TAP BELOW; 25 KVA TO 500 KVA — SIX 2.5 PERCENT TAPS (2 ABOVE, 4 DEEP—DISCHARGE LEVEL. WHEN NORMAL VOLTAGE IS RESTORED, RELAY MS 3860 WY C-1967 WHEN RESTRICTED OTHERWISE. UNLESS INDICATED OTHERWISE ON THE DRAWINGS. BELOW); ABOVE 500 KVA — FOUR 2.5 PERCENT (2 ABOVE, 2 BELOW). DISCONNECTS LAMPS FROM BATTERY, AND BATTERY IS AUTOMATICALLY HAVE A RATING BASED ON UL TESTING AT 50% POWER FACTOR FOR BALLAST ALL BRANCH CIRCUIT WIRING: NOT SMALLER THAN NO. 12 AWG. IF NO CONDUCTOR WHEN SPECIFICALLY DISALLOWED BY THE LOCAL AHJ. RECHARGED AND FLOATED ON CHARGER. LOADS, BE UL LISTED, AND MEET ALL APPLICABLE AGENCY REQUIREMENTS Professional Seal: SIZE IS INDICATED ON THE DRAWINGS FOR A BRANCH CIRCUIT, PROVIDE WHEN SPECIFICALLY DISALLOWED BY THE LANDLORD. FOR EXTERIOR UNATTENDED, WET LOCATIONS OR OTHER LOCATIONS AS TRANSFORMER CORE AND COIL ASSEMBLIES: MOUNTED ON INTEGRAL VIBRATION— CONDUCTORS AND CONDUIT SIZED PER NFPA 70 AND BASED ON THE INDICATED CIRCUITS THAT CAN BE SUPPLIED BY AN EMERGENCY OR STANDBY POWER INDICATED: IN—USE NEMA 3R RECESSED OR FLUSH MOUNT, UL—LABELED PLATES ABSORBING PADS. TEST PUSH BUTTON: PUSH—TO—TEST TYPE, IN UNIT HOUSING, SIMULATES LOSS OF BE STEM—MOUNTING TYPE WITH ALL NECESSARY MOUNTING HARDWARE AND BRANCH CIRCUIT OVERCURRENT PROTECTIVE DEVICE (OCPD) RATING AND NUMBER SOURCE. NORMAL POWER AND DEMONSTRATES UNIT OPERABILITY. INSTRUCTIONS; HAVE A HOUSING CONSTRUCTED OF HIGH IMPACT POLY— �E� i RIFF MOLDED FROM A CLEAR HIGH IMPACT ULTRAVIOLET STABILIZED POLYCARBONATE F. S OF POLES. WHERE NO CIRCUIT SIZE (I.E., CONDUCTORS AND OCPD) IS INDICATED — MATERIAL FOR EASY VERIFICATION THAT CORDS ARE PLUGGED IN AND THAT THE TRANSFORMERS 75 KVA AND LARGER SHALL BE FLOOR MOUNTED UNLESS CARBONATE; PHOTO CONTROL COMPONENTS CONSISTING OF A METAL FILM C_ NGINSF S' ON THE DRAWINGS FOR A BRANCH CIRCUIT, PROVIDE THREE NO. 12 AWG $PT INDICATED OTHERWISE. TRANSFORMERS 45 KVA AND SMALLER MAY BE WALL LED INDICATOR LIGHT: INDICATES NORMAL POWER ON. NORMAL GLOW INDICATES RESISTOR, DUAL TEMPERATURE COMPENSATING 81—METAL BLADES, SNAP ACTION C 4 CONDUCTORS, IN 3/4—INCH RACEWAY, AND A 20A CIRCUIT BREAKER. 16B JUNCTION BOXES, PULL BOXES, CABINETS AND WIREWAYS GFCI IS FUNCTIONING. BACK BOX MUST BE SUITABLE FOR CONDUIT CONNECTING. �G COORDINATE BACK BOX WITH WALL DEPTH. INTERMATIC WP1000RC/HRC OR EQUAL. MOUNTED WHERE WALL CONSTRUCTION IS SUITABLE FOR THE LOAD. FLOOR TRICKLE CHARGE; BRIGHT GLOW INDICATES CHARGING AT END OF DISCHARGE CONTACT BLADES, CHEMICALLY TREATED/POLYMER ENCAPSULATED CADMIUM 2 v MOUNTED TRANSFORMERS SHALL BE SECURELY BOLTED TO A 4 INCH HOUSE CYCLE. SULFIDE PHOTOCELL AND SILVER ALLOY CONTACTS TO ENSURE RELIABLE 5 YEAR 17547PE CONTROL WIRING: STRANDED COPPER CONDUCTORS, 600V INSULATION, OF THE PROVIDE JUNCTION BOXES, PULL BOXES, CABINETS AND WIREWAYS WHEREVER FOR ATTENDED WET OR DAMP LOCATIONS: WEATHERPROOF COVER PLATES UL— KEEPING PAD WITH VIBRATION ISOLATION PADS. WALL MOUNTED OR SUSPENDED MANUFACTURER WARRANTED OPERATION. PHOTO CONTROL SHALL BE 100% PROPER TYPE, SIZE AND NUMBER AS REQUIRED TO ACCOMPLISH SPECIFIED NECESSARY FOR PROPER INSTALLATION OF VARIOUS ELECTRICAL SYSTEMS LISTED FOR WET LOCATIONS WITH COVER( ) S CLOSED; DIE—CAST ALUMINUM OR TYPE TRANSFORMERS SHALL HAVE A MEANS OF ISOLATING VIBRATION FROM THE REMOTE TEST: SWITCH IN HAND—HELD REMOTE DEVICE AIMED IN DIRECTION OF FACTORY TESTED FOR FUNCTION WITHIN MANUFACTURER'S SPECIFIED LIGHT FUNCTION. MINIMUM SIZE: NO. 14 AWG, UNLESS NOTED OTHERWISE. ACCORDING TO NFPA 70 AND WHERE INDICATED ON THE DRAWINGS. SIZE AS 302 STAINLESS STEEL; SINGLE—COVER FOR SWITCHES AND VERTICALLY MOUNTED SUPPORT. TESTED UNIT INITIATES CODED INFRARED SIGNAL. SIGNAL RECEPTION BY FACTORY— LEVELS. 2 <r REQUIRED FOR THE SPECIFIC FUNCTION OR AS REQUIRED BY NFPA 70, WHICHEVER RECEPTACLES; DOUBLE—COVER FOR HORIZONTALLY MOUNTED RECEPTACLES; INSTALLED INFRARED RECEIVER IN TESTED UNIT TRIGGERS SIMULATION OF LOSS OF , OREGON o,7' FLEXIBLE CORDS AND CABLES: STRANDED COPPER CONDUCTORS FOR ALL, UNLESS IS LARGER. CONSTRUCTION SHALL BE OF A NEMA DESIGN SUITABLE FOR THE TRANSFORMERS UP THROUGH 1000 KVA SHALL BE MOUNTED ON ELASTOMERIC ITS NORMAL POWER SUPPLY, PROVIDING VISUAL CONFIRMATION OF EITHER PROPER BE FROM THE SAME MANUFACTURER OF AND TOTALLY COMPATIBLE WITH THE TIME11 NOTED OTHERWISE. ENVIRONMENT INSTALLED. SELF—CLOSING COVERS. VIBRATION ISOLATION PADS. PAD SHALL BE CONSTRUCTED OF NEOPRENE, RUBBER, OR FAILED EMERGENCY RESPONSE. SWITCHES SPECIFIED ABOVE. C?4 , 13 E,3 Q� SPECIAL PURPOSE CONDUCTORS AND CABLES, SUCH AS LOW VOLTAGE CONTROL JUNCTION BOXES INSTALLED BEHIND WALL CASES, AND IN OR ON OTHER STORE COVER PLATES: BY THE SAME MANUFACTURER AS THE WIRING DEVICES; GLASS FIBER, OR A COMBINATION THEREOF. PADS SHALL BE "RIBBED" OR INTEGRAL SELF—TEST: FACTORY—INSTALLED ELECTRONIC DEVICE AUTOMATICALLY �/ f�, P\4 COMPLYING WITH NFPA 70 406.8 (A) OR (B) REQUIREMENTS FOR ATTENDED OR WAFFLED' IN TEXTURE. PADS SHALL BE SELECTED FOR SMALLEST DUROMETER AND SHIELDED INSTRUMENT WIRING: UNLESS INDICATED OTHERWISE, SHALL BE AS FIXTURES, EXCEPT WHERE OTHERWISE SPECIFIED, SHALL BE 4—INCH SQUARE OR UNATTENDED USE AS APPLICABLE. (HARDNESS), PREFERABLY LESS THAN 50. DEFLECTION OF PAD SHALL BE .25" INITIATES CODE—REQUIRED TEST OF UNIT EMERGENCY OPERATION AT REQUIRED 166 MISCELLANEOUS EQUIPMENT AND CONNECTIONS , RECOMMENDED BY THE SYSTEM EQUIPMENT MANUFACTURER. LARGER, WITH GALVANIZED COVERS. STATIC MINIMUM. STACK PADS UNTIL THE DESIRED DEFLECTION IS ACHIEVED. INTERVALS. TEST FAILURE IS ANNUNCIATED BY AN INTEGRAL AUDIBLE ALARM AND I/ FLASHING RED LED. ALL WIRING AND CONNECTIONS TO ILLUMINATED CASES. S: 1 /201G TYPE MC CABLE: 60OV, UNJACKETED; ANSI E119 AND E814, UL STANDARDS 44 OR 83 HORIZONTALLY MOUNT JUNCTION BOXES UNDER CENTER FIXTURES (AND CASES), MAKE FINAL CONDUIT CONNECTIONS TO TRANSFORMERS WITH FLEXIBLE CONDUIT, (AS APPLICABLE), AND 1569, NFPA 70 ARTICLE 330; ALUMINUM OR GALVANIZED STEEL HANDY BOXES OR 4—INCH SQUARE BOXES WITH TOPS OF BOXES NOT MORE THAN 3— 16B ELECTRICAL SERVICE AND GROUNDING WITH AT LEAST 6 INCHES OF SLACK IN ALL DIRECTIONS. ALL WIRING AND CONNECTIONS TO EQUIPMENT FURNISHED BY OTHERS, INCLUDING, 166 LAMPS BUT NOT LIMITED TO P.O.S. STATIONS, ETC. INTERLOCKED ARMOR; THHN— OR XHHW—INSULATED CONDUCTORS; COLOR CODE: 1/2 INCHES ABOVE THE FLOOR. SIZE JUNCTION BOXES TO ADEQUATELY CONTAIN 16B ELECTRICAL SERVICE Consultant ICER METHOD 1, WITH GREEN INSULATED GROUNDING CONDUCTOR ALL REQUIRED CONDUCTORS AND SPLICES. TRANSFORMER ENCLOSURES: FULLY ENCLOSED (EXCEPT FOR VENTILATION SEE DRAWINGS FOR TYPESIZEVOLTAGE, PHASE, AND OTHER REQUIREMENTS. OPENINGS), NEMA 2, DRIP—PROOF, FABRICATED OF HEAVY GAUGE SHEET STEEL PROVIDE LAMPS AS INDICATED ON THE DRAWINGS FOR ALL LIGHT FIXTURES; OR, IF ALL RACEWAYS, AND ALL WIRING AND CONNECTIONS OF DEVICES TO ENERGY , , 16B INSTALLATION OF CONDUCTORS AND CABLES 16B OUTLET BOXES CONSTRUCTION NOT INDICATED, AS RECOMMENDED BY THE LIGHT FIXTURE MANUFACTURER. IN ALL MANAGEMENT SYSTEM THAT ARE NOT THE RESPONSIBILITY OF DIVISION 15. PROVIDE, OR ARRANGE WITH THE SERVING UTILITY FOR INSTALLATION TO PROVIDE, CASES, LAMPS SHALL BE COMPATIBLE WITH THE SPECIFIED LIGHT FIXTURE. INSTALL ALL WIRING IN APPROVED RACEWAY AND ENCLOSURES, EXCEPT: ALL OUTLETS INCLUDING LIGHT FIXTURE, SWITCH, RECEPTACLE, AND SIMILAR A RECORDING VOLTMETER AT THE SERVICE POINT, ON THE FIRST DAY THE FACILITY PROVIDE ENERGY—EFFICIENT TRANSFORMERS COMPLYING WITH NEMA TP-1, WHEN ACCEPTABLE LAMP MANUFACTURERS: GENERAL ELECTRIC, OSRAM/SYLVANIA, ALL WIRING AND CONNECTIONS OF EXIT DOOR ALARMS. WHERE SPECIFIED OR INDICATED FOR LOW—VOLTAGE WIRING OUTLETS: NATIONAL ELECTRICAL, APPLETON, STEEL CITY, RACO, OR APPROVED IS OPEN FOR BUSINESS, FOR A 24—HOUR VOLTAGE TEST. IF VOLTAGE AND TESTED IN ACCORDANCE WITH NEMA TP-2. PHILIPS, OR VENTURE. H EN D ERSON WHERE SPECIFIED OR INDICATED FOR DIRECT—BURIED CABLES EQUAL, GALVANIZED STEEL KNOCKOUT BOXES, SUITABLE IN DESIGN TO THE REGULATION ARE NOT WITHIN ACCEPTABLE LIMITS, ARRANGE WITH THE UTILITY FOR 16B EXISTING FIRE ALARM SYSTEM MODIFICATIONSF7 WHERE TYPE MC CABLE IS INDICATED OR SPECIFIED AS ACCEPTABLE. PURPOSE THEY SERVE AND THE SPACE THEY OCCUPY. SIZE AS REQUIRED FOR THE PROPER VOLTAGE. SUBMIT TO THE OWNER A REPORT OF MAXIMUM AND MINIMUM K—RATED TRANSFORMERS SHALL BE PROVIDED AS INDICATED ON THE DRAWINGS ALL FLUORESCENT LAMPS SHALL BE MINIMUM OF 3500 DEGREES K, WITH A MINIMUM ,J SPECIFIC FUNCTION OR AS REQUIRED BY NFPA 70, WHICHEVER IS LARGER. SET ALL VOLTAGE AND A COPY OF THE RECORDING VOLTMETER CHARTAND BE LISTED FOR 115 DEGREE C RISE. COLOR—RENDERING INDEX OF 70, UNLESS NOTED OR DIRECTED OTHERWISE. ALL PROVIDE NEW EQUIPMENT, COMPATIBLE WITH, AND CONNECTED TO, THE EXISTING ENGINEERS_ . INSTALL ALL CONDUCTORS AND CABLE IN RACEWAYS CONTINUOUS WITHOUT TAPS OUTLET BOXES IN WALLS, COLUMNS, FLOORS, OR CEILINGS SO THEY ARE FLUSH FLUORESCENT LAMPS IN SALES AREAS SHALL BE 3000 DEGREES K WITH A COLOR— FIRE ALARM CONTROL SYSTEM. MODIFY IN ACCORDANCE WITH NFPA 72 AS OR SPLICES. SPLICE OR TAP ONLY IN APPROVED BOXES AND ENCLOSURES WITH WITH THE FINISHED SURFACE, ACCURATELY SET, AND RIGIDLY SECURED IN 16B CONNECTION TO SERVING UTILITIES MANUFACTURERS: SQUARE D, CUTLER HAMMER, GENERAL ELECTRIC, HAMMOND, RENDERING INDEX OF 80. APPLICABLE AND WITH THE AHJ. 8345 LENEXA DRIVE,SUITE 300 APPROVED SOLDERLESS CONNECTORS, OR CRIMP CONNECTORS AND TERMINAL POSITION. PROVIDE PLASTER RINGS, EXTENSION RINGS AND/OR MASONRY RINGS ACME OR SIEMENSALL METAL HALIDE LAMPS IN SALES AREAS SHALL BE COATED, 3000 DEGREES K 1LENEXA,KS 66214 BLOCKS FOR CONTROL WIRING, AND KEEP TO THE MINIMUM REQUIRED. INSULATE AS REQUIRED FOR FLUSH MOUNTING. PROVIDE APPROVED CAST OUTLET BOXES, . PROVIDE ALL REQUIRED INITIATING DEVICES, NOTIFICATION APPLIANCES, AUXILLARY 42 5000 ALL SPLICES, TAPS, AND JOINTS AS REQUIRED BY CODES. WITH HUBS AND WEATHERPROOF COVERS, IN ALL AREAS SUBJECT TO DAMP, WET, PROVIDE RACEWAYS, TERMINATIONS, METERING PROVISIONS, AND MISCELLANEOUS DEVICES AND INTERCONNECTING CIRCUITS. TEL 913 IV.he FAX9c m SOOT EQUIPMENT, AS REQUIRED, FOR ELECTRICAL AND TELEPHONE SERVICES FOR 166 FRACTIONAL HORSEPOWER MANUAL MOTOR STARTERS WITH ACOLOR—RENDERING INDEX OF 70. OR HARSH CONDITIONS. www.hei-eng.eom CONNECTION BY THE SERVING UTILITY, IN STRICT COMPLIANCE WITH THE INCANDESCENT LAMPS: TYPE AND WATTAGE AS SHOWN ON THE DRAWINGS; RATED 2. PROVIDE ADDITIONAL AUXILLARY PANELS AS REQUIRED TO POWER NEW EQUIPMENT ALL MATERIALS USED TO TERMINATE, SPLICE OR TAP CONDUCTORS: DESIGNED FOR, REQUIREMENTS OF ALL APPLICABLE CODES AND OF THE SERVING UTILITY FRACTIONAL HORSEPOWER MANUAL MOTOR STARTERS SHALL BE: 1550003152 PROPERLY SIZED FOR, AND UL LISTED FOR THE SPECIFIC APPLICATION AND 166 OUTLET LOCATIONS 130V UNLESS OTHERWISE SCHEDULED OR SPECIFIED. FOR SCOPE OF WORK. INVOLVED. VERIFY ALL SERVICE TERMINATIONS AND CONNECTION POINTS IN THE CONDUCTORS INVOLVED, AND INSTALLED IN STRICT ACCORDANCE WITH THE SQUARE D CLASS 2510, TYPE F MANUFACTURER'S RECOMMENDATIONS, USING THE MANUFACTURER'S COORDINATE LOCATIONS OF OUTLET BOXES. OUTLETS ARE ONLY APPROXIMATELY FIELD AND WORK IN CONJUNCTION WITH THE UTILITY INVOLVED IN THE 166 BALLASTS 3. SEQUENCE OF OPERATIONS SHALL MATCH THAT OF THE EXISTING SYSTEM. RECOMMENDED TOOLS. INSTALLATION OF ALL SERVICES. PROVIDE ALL MATERIALS AND EQUIPMENT GENERAL ELECTRIC CR101 G LOCATED ON THE SMALL SCALE DRAWINGS. USE GREAT CARE IN THE ACTUAL SIEMENS MSF SERIES Job Name and Number. 2015-0131 LOCATION BY CONSULTING THE VARIOUS LARGE SCALE DETAILED DRAWINGS USED REQUIRED FOR COMPLETE UTILITY CONNECTION BUT NOT FURNISHED BY THE FLUORESCENT BALLASTS: LOW HEAT TYPE: THERMALLY PROTECTED AGAINST 4. ALL WIRING AND CABLE SHALL MATCH THAT OF THE EXISTING SYSTEM AND BE IN SERVING UTILITY. NOTIFY THE UTILITY COMPANIES INVOLVED WITHIN TWO WEEKS WESTINGHOUSE MST SERIES OVERHEATING; ETL—CBM, CLASS P TO MEET ALL REQUIREMENTS OF SECTION 410-73 ACCORDANCE WITH APPLICABLE CODES. WHERE WIRING IS INDICATED AS INSTALLED, BUT THE CONNECTION IS INDICATED BY OTHER DIVISION TRADES, AND BY SECURING DEFINITE LOCATIONS FROM THE AFTER NOTICE TO PROCEED, OF ALL REQUIRED INFORMATION NECESSARY FOR THE CUTLER HAMMER 9101 SERIES "FUTURE" OR "BY OTHER DIVISION, TRADES, OR CONTRACTS", LEAVE A MINIMUM 3— ARCHITECT. (E) OF THE NFPA 70 AS A MINIMUM; COMPLY WITH THE NATIONAL BALLAST ENERGY FOOT "PIGTAIL" AT THE BOX TAPE THE ENDS OF THE CONDUCTORS, AND COVER THE UTILITY TO SUPPLY THE PROJECT WITHOUT DELAY. PAY ALL CHARGES OF THE MANUAL MOTOR STARTERS FOR FRACTIONAL HORSEPOWER SINGLE PHASE LAW; 90—PERCENT POWER FACTOR OR GREATER; SOUND LEVELS NOT EXCEEDING 5. CONTRACTOR SHALL INSTALL, PROGRAM AND TEST ALL NEW/EXISTING EQUIPMENT 80X. O 0 166 MOUNTING HEIGHTS SERVING UTILITY FOR THE ELECTRICAL SERVICE(S). MOTORS SHALL CONSIST OF A MANUALLY OPERATED TOGGLE SWITCH EQUIPPED CLASS A AMBIENT NOISE LEVELS. BALLASTS IN INDOOR LOCATIONS SHALL HAVE TO ENSURE SYSTEM FUNCTIONALITY PER NFPA 72 REQUIREMENTS FOR THE SCOPE Proposed sed]66 GROUNDING WITH MELTING ALLOY TYPE OVERLOAD RELAY. THERMAL UNIT SHALL BE OF ONE DISCONNECTING MEANS EITHER INTERNAL OR EXTERNAL TO THE LUMINAIRE. OF WORK. IN GENERAL, THE DIRECTION OF BRANCH CIRCUIT "HOME RUN" ROUTING IS UNLESS NOTED OTHERWISE, INSTALL WIRING DEVICES AS INDICATED BELOW (NOTE: PIECE CONSTRUCTION AND INTERCHANGEABLE. STARTER SHALL BE INOPERATIVE VE R IZO N PERMANENTLY AND EFFECTIVELY GROUND AND BOND THE ELECTRICAL INDICATED ON THE DRAWINGS, COMPLETE WITH CIRCUIT NUMBERS AND ALL DIMENSIONS ARE TO THE BOTTOM OF THE OUTLET BOX UNLESS NOTED IF THERMAL UNIT IS REMOVED. PROVIDE FLUSH MOUNTED UNITS IN FINISHED AREAS INDOOR FLUORESCENT BALLASTS: ELECTRONIC TYPE SUITABLE FOR OPERATION OF PANELBOARD DESIGNATION. CONTINUE ALL SUCH "HOME RUN" WIRING TO THE OTHERWISE): AND SURFACE MOUNTED UNITS IN UNFINISHED AREAS. STARTERS SHALL HAVE T8 LAMPS; TOTAL HARMONIC DISTORTION LESS THAN 20 PERCENT; FREQUENCY OF INSTALLATION IN A THOROUGH AND EFFICIENT MANNER, AND IN CONFORMANCE, AT STORE DESIGNATED PANELBOARD, AS THOUGH "CIRCUIT RUNS" WERE INDICATED IN THEIR A MINIMUM, WITH NFPA 70, OR THESE DOCUMENTS, WHERE THEY EXCEED CODE NEMA I GENERAL PURPOSE ENCLOSURE, UNLESS OTHERWISE INDICATED, AND BE OPERATION RA 20 KHZ DE GREATER WITH NO VISIBLE FLICKER; LINE TRANSIENT ENTIRETY. RECEPTACLES: REQUIREMENTS. USE BARE OR INSULATED CONDUCTORS, AS SPECIFIED HEREIN, RATED FOR THE MOTOR HORSEPOWER REQUIRED. WITHSTAND RATINGS AS DEFINED IN ANSI/IEEE C62.41, CATEGORY A; AND OTHER MATERIALS INDICATED ON THE DRAWINGS. MANUFACTURERS: ADVANCE REL/VEL SERIES OR APPROVED EQUAL BY MAGNETEK, THE NUMBER OF CONDUCTORS IN A SPECIFIC RACEWAY "HOME RUN" IS INDICATED VERTICALLY ALIGNED WITH THE GROUND SLOT MOUNTED AT THE TOP: BOTTOM OF PROVIDE MANUAL MOTOR STARTERS WITH AN INTEGRAL PILOT LIGHT. MOTOROLA, OR OSRAM. (LEED) WITH CROSS LINES (TICK MARKS) ON EACH "CIRCUIT RUN" ON THE DRAWINGS. OUTLET BOX 16 INCHES ABOVE FINISHED FLOOR. 16B LIGHTING AND APPLIANCE PANELBOARDS EXTERIOR AND LOW TEMPERATURE FLUORESCENT BALLASTS: SHALL BE 166 MANUAL MOTOR STARTERS ELECTRONIC TYPE SUITABLE FOR OPERATION OF F72T12/HO AND F96T12/HO LAMPS; COMMON OR SHARED NEUTRALS ARE NOT ALLOWED UNLESS SHOWN ON THE HORIZONTALLY ALIGNED, WITH NEUTRAL SLOT MOUNTED AT THE TOP: BOTTOM OF PANELBOARDS: SQUARE D TYPE NQOD OR NF, AS APPLICABLE, BASED ON VOLTAGE SHALL HAVE A TOTAL HARMONIC DISTORTION LESS THAN 20 PERCENT; SHALL HAVE DRAWINGS TO BE USED OR SPECIFICALLY NOTED TO BE ALLOWED. OUTLET BOX 16 INCHES ABOVE FINISHED FLOOR. AND AMPERE RATINGS AND REQUIRED SHORT—CIRCUIT INTERRUPTING RATINGS AS MOTOR STARTING SWITCHES SHALL BE: A FREQUENCY OF OPERATION OF 20 KHZ OR GREATER AND OPERATE WITH NO WHERE MULTIVISIBLE FLICKER; SHALL WITHSTAND LINE TRANSIENTS AS DEFINED IN ANSI/IEEE WIRE BRANCH CIRCUITS (I.E., SHARED NEUTRAL) ARE ALLOWED, THEY FOR 36—INCH HIGH COUNTER TOPS: 44 INCHES ABOVE FINISHED FLOOR, VERTICALLY SCHEDULED ON THE DRAWINGS, OR APPROVED EQUAL BY SIEMENS, CUTLER HAMMER, OR GENERAL ELECTRIC; COMPLETE WITH BOLT—ON THERMAL MAGNETIC, SQUARE D CLASS 2510, TYPE M C62.41, CATEGORY A; SHALL HAVE A MINIMUM STARTING TEMPERATURE OF —20 SHALL BE PROVIDED WITH A MEANS THAT WILL SIMULTANEOUSLY DISCONNECT ALL ALIGNED. MOLDED CASE CIRCUIT BREAKERS ASSEMBLED IN A DEAD—FRONT FINISHED CABINET CONTAINING A TYPEWRITTEN CARD DIRECTORY INDICATING EXACTLY WHAT EACH GENERAL ELECTRIC CR1062 DEGREES F; AND SHALL BE ADVANCE REL/VEL SERIES OR EQUAL OF MAGNETEK OR UNGROUNDED CONDUCTORS AT THE POINT THE BRANCH CIRCUIT ORIGINATES. SIEMENS MS SERIES MULTI—POLE BREAKERS OR 3 SINGLE POLE BREAKERS WITH A HANDLE TIE ARE TWO FOR 34—INCH HIGH COUNTER TOPS: 40 INCHES ABOVE FINISHED FLOOR, VERTICALLY WESTINGHOUSE MST SERIES MOTOROLA. CIRCUIT BREAKER CONTROLS; FULLY OR SERIES RATED AND WITH THE INTEGRATED kbAddress EXAMPLES. ALIGNED. CUTLER HAMMER 9115 OR A302 SERIES SH N THE DRAWINGS. PLUG—IN TYPE ORT CIRCUIT CURRENT RATINGS INDICATED 0 EXTERIOR AND LOW TEMPERATURE FLUORESCENT BALLASTS: SHALL BE MAGNETIC WHEN MULTIPLE HOME RUNS ARE COMBINED INTO A SINGLE RACEWAY SUCH THAT MECHANICAL AND ELECTRICAL EQUIPMENT ROOMS AND JANITORS CLOSETS: 44 BREAKERS WILL NOT BE ACCEPTABLE. ALL TWO AND THREE POLE BREAKERS: TYPE SUITABLE FOR OPERATION OF T12 LAMPS; SHALL HAVE A MINIMUM STARTING Washington Square Mall 1 COMMON TRIP TYPE. BREAKERS USED AS SWITCHES FOR 20V OR 277V LIGHTING MANUAL MOTOR STARTERS SHALL CONSIST OF A MANUALLY OPERATED SWITCH THE NUMBER OF CONDUCTORS EXCEEDS FOUR (CONDUCTOR COUNT IS MADE UP INCHES ABOVE FINISHED FLOOR, VERTICALLY ALIGNED. CIRCUITS: APPROVED FOR THE PURPOSE AND MARKED R 12 BREAKERS USED FOR EQUIPPED WITH MELTING ALLOY TYPE THERMAL OVERLOAD RELAYS. THERMAL UNIT TEMPERATURE OF 0 DEGREES F FOR RAPID START LAMPS AND A MINIMUM STARTING 9585 S.W. Washington OF ANY COMBINATION OF PHASE AND NEUTRAL CONDUCTORS), THE FOLLOWING SHALL BE OF ONE PIECE CONSTRUCTION AND INTERCHANGEABLE. STARTER SHALL TEMPERATURE OF —20 DEGREES F FOR 800MA AND 1500MA LAMPS; AND SHALL BE g RESTRICTIONS APPLY, WHICH ARE IN ADDITION TO THOSE IN NFPA 70: GARAGES: 24 INCHES A60VE FINISHED FLOOR, VERTICALLY ALIGNED. THE PROTECTION OF HVAC AND REFRIGERATION EQUIPMENT: HACR TYPE. BE INOPERATIVE IF THERMAL UNIT IS REMOVED. PROVIDE FLUSH MOUNTED UNITS IN ADVANCE REL SERIES OR EQUAL OF MAGNETEK. 166 CIRCUIT BREAKERS IN EXISTING PANELBOARDS AND SWITCHBOARDS FINISHED AREAS AND SURFACE MOUNTED UNITS IN UNFINISHED AREAS. STARTERS Square Road NORMAL OR NON—ESSENTIAL CIRCUITS. WEATHERPROOF EXTERIOR RECEPTACLES: 24 INCHES ABOVE FINISHED GRADE SHALL HAVE NEMA I GENERAL PURPOSE ENCLOSURE, UNLESS OTHERWISE COMPACT FLUORESCENT BALLASTS: SHALL BE THERMALLY PROTECTED AGAINST Portland O VERTICALLY ALIGNED. INDICATED, AND BE RATED FOR THE MOTOR HORSEPOWER REQUIRED. OVERHEATING; SHALL BE CLASS P; SHALL HAVE A MINIMUM 90 PERCENT POWER r OR 97223 3 PROVIDE NEW CIRCUIT BREAKERS FOR INSTALLATION IN EXISTING PANELBOARDS FACTOR; SOUND LEVELS SHALL NOT EXCEED CLASS A AMBIENT NOISE LEVELS; AND Space R05-R07 q MAXIMUM OF 16 CONDUCTORS IN A SINGLE RACEWAY. FOR UP TO EIGHT AND SWITCHBOARDS, OF THE SAME MANUFACTURER AND TYPE AS THE EXISTING PROVIDE MANUAL MOTOR STARTERS WITH AN INTEGRAL PILOT LIGHT. SHALL BE LOW HEAT TYPE. ALL BALLASTS SHALL BE BY ADVANCE. BALLASTS FOR CONDUCTORS IN A RACEWAY, MINIMUM RACEWAY SIZE: 3/4—INCH. GFCI RECEPTACLES: SAME AS GENERAL RECEPTACLES. PANELBOARD AND SWITCHBOARD CIRCUIT BREAKERS. SHORT CIRCUIT CURRENT 36W THRU 55W LAMPS SHALL BE MARK V ELECTRONIC TYPE. 11iN FOR GREATER THAN EIGHT CONDUCTORS, MINIMUM RACEWAY SIZE: 1—INCH. INTERRUPTING RATING OF ANY NEW BREAKER MUST BE THE LARGER OF THE 16B MOTOR STARTING SWITCHES u7 DO NOT INSTALL ANY OTHER TYPE OF CIRCUIT IN THIS RACEWAY. ISOLATED GROUND RECEPTACLES: SAME AS GENERAL RECEPTACLES. EXISTING PANEL RATING OR THE AVAILABLE FAULT CURRENT INDICATED ON THE HIGH—INTENSITY DISCHARGE (HID) BALLASTS (INCLUDES HIGH PRESSURE SODIUM O THE MINIMUM WIRE SIZE FOR ALL CONDUCTORS IN THIS RACEWAY: N0. 10 AWG. SPD RECEPTACLES: SAME AS GENERAL RECEPTACLES. DRAWINGS. MOTOR STARTING SWITCHES SHALL BE: (HPS) AND METAL HALIDE (MH)): SHALL HAVE A POWER FACTOR GREATER THAN 90 Draw111tle' PERCENT; COMPLY WITH UNDERWRITERS LABORATORY (UL) 1029; PROVIDE NORMAL ELECTRICAL >; O 16B SERIES RATINGS ON SWITCHBOARDS AND PANELBOARDS SQUARE D CLASS 2510, TYPE K OPERATION AND LIGHT OUTPUT WITH THE INPUT VOLTAGE IS WITHIN 110 c ONLY 15A AND 20A BRANCH CIRCUIT HOMERUNS MAY BE COMBINED INTO ONE CLOCK RECEPTACLES: 84 INCHES ABOVE FINISHED FLOOR. PERCENT OF NOMINAL BALLAST RATING EXCEPT HPS LAMPS SMALLER THAN 250W m GENERAL ELECTRIC TC2000 SERIES ( SPECIFICATIONS j RACEWAY. CONCRETE BLOCK WALLS: DIMENSIONS ABOVE MAY BE ADJUSTED SLIGHTLY, AS LABEL SWITCHBOARDS AND PANELBOARDS WITH A UL INTEGRATED SHORT CIRCUIT SIEMENS MS SERIES WHICH MUST HAVE THE INPUT VOLTAGE WITHIN +5 PERCENT)- SHALL HAVE A = CURRENT RATING. WESTINGHOUSE MST SERIES MINIMUM STARTING TEMPERATURE OF —20 DEGREES F. PROVIDE ENCAPSULATED Co U REQUIRED TO COMPENSATE FOR VARIABLE JOINT DIMENSIONS, SUCH THAT BOTTOM CUTLER HAMMER 9115 SERIES P W GFCI CIRCUITS. AND REMOTE TYPES WHERE INDICATED ON THE DRAWINGS. .D J OR TOP OF BOXES, AS APPLICABLE, ARE AT BLOCK JOINTS. WHEN SERIES RATINGS ARE APPLIED WITH INTEGRAL OR REMOTE UPSTREAM < j DO NOT USE MULTI—CONDUCTOR CIRCUITS, WITH A SHARED NEUTRAL, FOR ANY SWITCHES: DEVICES, PROVIDE LABELS COMPLYING WITH NFPA 70 ARTICLES 240.86 AND 110.22. MOTOR STARTING SWITCHES SHALL CONSIST OF A TOGGLE OPERATED TWO OR EMERGENCY FLUORESCENT BALLASTS: SHALL BE BODINE 850 OR IOTA 1-232 FOR : 0O GFCI CIRCUIT BREAKER OR RECEPTACLE CIRCUIT. IN ADDITION TO THE WARNING LABEL, INCLUDE, AT A MINIMUM, THE FOLLOWING THREE POLE SWITCH. CONTACTS SHALL BE DOUBLE BREAK SILVER ALLOY, VISIBLE FOUR—FOOT FLUORESCENT LAMPS; SHALL BE BODINE B30 OR IOTA 1-160 FOR EIGHT— M O GENERAL: TOP OF OUTLET BOX A MAXIMUM OF 48 INCHES ABOVE FINISHED FLOOR. CONDITIONS OF THE UL 67 SERIES RATINGS: FROM BOTH SIDES OF THE SWITCH AND SHALL HAVE A DIRECT LINKAGE TO THE FOOT FLUORESCENT LAMPS; OR AS NOTED ON THE FIXTURE SCHEDULE OR rn O EMERGENCY POWER CIRCUITS — INCLUDES ALL CIRCUITS COVERED UNDER ALL SWITCHES SHALL BE MOUNTED AT THE SAME HEIGHT THROUGHOUT THE OPERATOR FOR POSITIVE BREAK. PROVIDE FLUSH MOUNTED UNITS IN FINISHED ELSEWHERE ON THE DRAWINGS. ARTICLES 700, 701 AND 702. PROJECT UNLESS NOTED OTHERWISE. 1. SIZE AND TYPE OF UPSTREAM DEVICE. AREAS AND SURFACE MOUNTED UNITS IN UNFINISHED AREAS. STARTERS SHALL HAVE NEMA I GENERAL PURPOSE ENCLOSURE, UNLESS OTHERWISE INDICATED, AND 16B DIMMABLE LIGHT FIXTURES Drawney: North in I MAXIMUM OF EIGHT CONDUCTORS IN A SINGLE RACEWAY. 2. BRANCH DEVICES THAT CAN BE USED. BE RATED FOR THE MOTOR HORSEPOWER REQUIRED. Arrow: o MINIMUM RACEWAY SIZE: 3/4—INCH. ABOVE COUNTERS: SAME AS FOR RECEPTACLES. LKV O / FOR DIMMABLE LIGHT FIXTURES PROVIDE BOTH CONTROL AND POWER WIRING �`, Of DO NOT INSTALL ANY OTHER TYPE OF CIRCUIT IN THIS RACEWAY. 3. UL SERIES SHORT CIRCUIT CURRENT RATING. PROVIDE HANDLE GUARD WITH LOCKING PROVISIONS. BETWEEN LIGHT FIXTURE AND CONTROL DEVICE AND BETWEEN LIGHT FIXTURES. Df. ¢ CONCRETE BLOCK WALLS: 40 INCHES ABOVE FINISHED FLOOR (DIMENSION MAY BE N O ADJUSTED SLIGHTLY, AS REQUIRED TO COMPENSATE FOR VARIABLE JOINT QUANTITY OF LOW VOLTAGE AND LINE VOLTAGE WIRING AND WIRE TYPE SHALL BE AJQ 0 1= ONLY 15A AND 20A BRANCH CIRCUIT HOMERUNS MAY BE COMBINED INTO WHEN THERE IS NOT ENOUGH ROOM IN THE EQUIPMENT TO SHOW ALL THE PER MANUFACTURER'S RECOMMENDATIONS. COORDINATE LIGHT FIXTURE AND DIMENSIONS, SUCH THAT BOTTOM OF BOXES ARE AT BLOCK JOINTS). LEGITIMATE SERIES RATED COMBINATIONS, REFERENCE A BULLETIN SUPPLIED WITH Dee Issued For o I ONE RACEWAY. 16B LIGHT FIXTURES. LAMPS AND BALLASTS CONTROL DEVICE DIMMING TYPES FOR COMPATIBILITY. F, THE PANELBOARD, PER UL 67. Client 12/24/2015 FOR BRANCH CIRCUITS FED FROM GFCI CIRCUIT BREAKERS, LIMIT THE ONE—WAY WALLS WITH WAINSCOTING: 6 INCHES MINIMUM ABOVE WAINSCOTING, BUT NOT 3 CK EXCEEDING 48 INCHES ABOVE FINISHED FLOOR. SERIES RATINGS SHALL COVER ALL TRIP RATINGS OF INSTALLED FRAMES. 16B LIGHT FIXTURE LOCATIONS Landlord, -o Q CONDUCTOR LENGTH TO 100 FEET BETWEEN THE PANELBOARD AND THE MOST 16B MISCELLANEOUS ELECTRICAL N � REMOTE RECEPTACLE OR LOAD ON THE GFCI CIRCUIT. MULTI—OUTLET ASSEMBLIES: LIGHT FIXTURES SHOWN ON THE ELECTRICAL DRAWINGS REPRESENT GENERAL Permit; i2/24/2015 � 16B DISCONNECT (,SAFETY) SWITCHES ARRANGEMENTS ONLY. REFER TO ARCHITECTURAL DRAWINGS FOR MORE EXACT 16B WIRING OF MECHANICAL EQUIPMENT co PROPERLY IDENTIFY ALL TERMINAL BLOCKS AND WIRE TERMINALS FOR CONTROL AS INDICATED ON THE DRAWINGS. LOCATIONS. COORDINATE LOCATION WITH ALL OTHER TRADES BEFORE Bid` o Z WIRING WITH VINYL STICK—ON MARKERS OR EQUIVALENT. PROVIDE ENGINEER WITH DISCONNECT (SAFETY) SWITCHES: SQUARE D, SIEMENS, CUTLER HAMMER, OR GENERAL ELECTRIC FUSED OR NON—FUSED AS INDICATED ON DRAWINGS OR INSTALLATION TO AVOID CONFLICTS. COORDINATE LIGHT FIXTURE LOCATIONS IN PROVIDE ALL RACEWAYS AND POWER WIRING FOR ALL DIVISION 15 EQUIPMENT Construction LO A LIST OF PROPOSED IDENTIFYING NUMBERS FOR REVIEW PRIOR TO INSTALLING TELEPHONE/DATA OUTLET BOXES: ( MECHANICAL ROOMS WITH FINAL INSTALLED PIPING AND DUCTWORK LAYOUTS. REQUIRING ELECTRICAL CONNECTIONS, INCLUDING, BUT NOT LIMITED TO, PUMPS, REQUIRED NEMA KS1, HEAVY DUTY, EXTERNALLY OPERATED, VISIBLE—BLADE Revisionlssue: Z MARKERS. WATER HEATERS, AND HVAC EQUIPMENT, AND ALL LINE—VOLTAGE CONTROL AND m = SAFETY SWITCHES; NEMA ENCLOSURE TYPE INDICATED ON THE DRAWINGS OR No. Date Description GENERAL: MATCH MOUNTING HEIGHT OF ADJACENT WIRING DEVICE LISTED ABOVE. 166 LIGHT FIXTURES INTERLOCK WIRING NOT PROVIDED UNDER DIVISION 15. CONNECT PER w PROVIDE AN EQUIPMENT—GROUNDING CONDUCTOR, OR BONDING JUMPER, AS SUITABLE FOR THE ENVIRONMENT IN WHICH INSTALLED. BASED ON FUSIBLE SWITCH MANUFACTURERS' WIRING DIAGRAMS. COORDINATE WITH DIVISION 15 FOR 0 3 APPLICABLE, IN ALL FEEDERS AND BRANCH CIRCUITS, SIZED IN ACCORDANCE WITH WALL—MOUNTED TELEPHONE: 40 INCHES ABOVE FINISHED FLOOR. AND FUSE SIZES INDICATED, INCLUDE CLASS R, J, OR L FUSE PROVISIONS AS PROVIDE LIGHT FIXTURES AS SCHEDULED ON DRAWINGS, INCLUDING ALL LAMPS, DISCONNECTS FURNISHED WITH EQUIPMENT, AND PROVIDE ALL DISCONNECT NFPA 70 TABLES 250.66 OR 250.122, AS APPLICABLE, UNLESS INDICATED AS LARGER APPLICABLE. ALL NECESSARY ACCESSORIES, MATERIAL AND LABOR TO SECURELY HANG, CLEAN, SWITCHES AS REQUIRED. AFTER INSTALLING WIRING, VERIFY THAT EACH MOTOR O 1 ON THE DRAWINGS. FOR OTHER THAN WIRING DEVICES, REFER TO PARAGRAPHS, ARTICLES, SECTIONS, AND MAKE LIGHT FIXTURES COMPLETELY READY FOR USE. LIGHT FIXTURE MODEL LOAD HAS THE CORRECT PHASE ROTATION. DIVISIONS, OR DRAWINGS TO OBTAIN MOUNTING HEIGHTS FOR SPECIFIC EQUIPMENT NUMBERS SCHEDULED ON THE DRAWINGS SHOW ONLY THE MANUFACTURER, rn VOLTAGE DROP IN FEEDER CIRCUITS SHALL NOT EXCEED 2 PERCENT. OR SYSTEMS. GRADE AND STYLE OF LIGHT FIXTURES REQUIRED. PROVIDE: ALL HANGERS, VERIFY THE ACTUAL "MAXIMUM OVERCURRENT PROTECTION" (MOCP) DEVICE ,T VOLTAGE DROP IN BRANCH CIRCUITS SHALL NOT EXCEED 3 PERCENT. SUPPORTS, AND MISCELLANEOUS HARDWARE REQUIRED TO INSTALL LIGHT RATINGS AND "MINIMUM CIRCUIT AMPACITY" (MCA) CONDUCTOR SIZING FOR aT � FIXTURES: PROPER TRIM TO FIT EACH CEILING CONDITION ACTUALLY MECHANICAL EQUIPMENT FROM THE EQUIPMENT NAMEPLATE. BASE ELECTRICAL WIRING SHALL HAVE INSULATION OF THE PROPER COLOR TO MATCH COLOR CODE ENCOUNTERED; ADDITIONAL TIE WIRES CONNECTED TO STRUCTURE TO CONFORM INSTALLATIONS ON ACTUAL REQUIRED AMPERAGES, WHICH MAY VARY SOMEWHAT = r7 SYSTEM IN THE TABLE BELOW UNLESS THERE IS A COLOR SYSTEM CURRENTLY IN TO SEISMIC REQUIREMENTS WHERE REQUIRED BY THE APPLICABLE BUILDING CODE. FROM THE CONDUCTOR AND EQUIPMENT SIZES SHOWN ON THE DRAWINGS; rn p USE BY THE FACILITY, IN WHICH CASE THE COLORS ARE TO MATCH THE EXISTING HOWEVER, IN NO CASE, REDUCE THE SIZE OF CONDUCTORS INDICATED ON THE o SYSTEM. IN LARGER SIZES, WHERE PROPERLY COLORED INSULATION IS NOT DRAWINGS WITHOUT AUTHORIZATION FROM THE ENGINEER. PROVIDE PROPERLY to m LO AVAILABLE, USE VINYL PLASTIC ELECTRICAL TAPE OF THE APPROPRIATE COLOR SIZED ELECTRICAL WIRING AND EQUIPMENT WITHOUT EXTRA COST TO THE OWNER. w AROUND EACH CONDUCTOR AT ALL TERMINATION POINTS, JUNCTION AND PULL NOTIFY THE ENGINEER OF ALL CHANGES REQUIRED IN THE ELECTRICAL c Z BOXES. INSTALLATION DUE TO EQUIPMENT VARIANCES SO THAT THE EFFECTS ON FEEDERS, O BRANCH CIRCUITS, PANELBOARDS, FUSES AND CIRCUIT BREAKERS CAN BE N N CHECKED PRIOR TO PURCHASING AND INSTALLATION. BE RESPONSIBLE FOR �f COORDINATING WITH DIVISION 15 TO VERIFY THE ACTUAL AMPACITIES AND IN j CORRECT SIZES OF ALL CONDUCTORS AND OVERCURRENT PROTECTIVE DEVICES N FOR ALL EQUIPMENT, AND CORRECT OVERLOAD HEATERS FOR ALL MOTORS, WHEN o I STARTERS ARE PROVIDED UNDER DIVISION 16. CD u� W 0 Q DrawingNumbec > _ ¢¢O N a E 2 oC.7 Z oo � E7 L �(- 290F31 m U c m J_ 7 Sustainable Design and Construction Procedures: Coordination &,Meetings LEED TM Submittals Construcl on Waste Management (CWM): amount of any money paid or received for the recycled 5. Cleaning: Use low-toxic cleaning supplies for surfaces, TMor salvaged material, and the total disposal cost equipment and worker's personal use. Options include LEED RequirementsTM TM Contractor shall 'coordinate all aspects of the LEED work with all Achievement of LEED requirements are documented through including transportation costs, container rental costs, Green Seal certified, citrus-based or soy-based TM CWM Requirements Sub-Contractors.. Coordination shall include activities for LEED submittals which are provided to the Owner's LEED taxes, etc. Include manifests, weight tickets receipts, solvent cleaners. Refer to Green Seal website for a GRUSKIN This project will apply to the US Green Building Council for Submittals, Substitutions, Construction Waste Management, Representative for use in the U S Green Building Council LEEDTM and invoices, Obtain recycling rates for each list of approved products at building certification under the Leadership in Energy and Indoor Air Quality Management, and Commissioning as outlined in application. Contractor submittals are required to create the 1• Contractor shall reuse, salvage, or recycle waste Environmental Design LEEDTM Green Building Rating S stem® the LEED Prototype Green Specifications. LEED Application. These submittals are identified on the materials to divert a minimum of 75% of total commingled material from each receiving facility httpServi/www.greenseal.argfFindGreenSealProductsAnd g ( } g g Y YP p pp where commingled waste materials are delivered. Services-aspx DESIGN.ARCHITECTURE + for Green Interior Design and Construction (2009 Edition). This project drawings. construction and demolition waste from landfill and 294 Morris Avenue Springfield,NJ 07081 rating system sets a standard definition for a commercial green Contractor shall designate a'LEEDTM Coordination Manager' fromincineration, and redirect recyclable material back to Tel: 973.376.441 1 Fax:973.376.8989 building. a permanent member of the construction team. The LEED TM Contractor shall provide the LEED TM Submittal Forms to Ownersmanufacturing process. Contractor Shall designate an 3. If: commingled recycling services are used, the 6. Gypsum Assemblies: Use wet sanding for gypsum www.Grusk!nGroup.com NJ REG0108-9869-14 Coordination Manager's responsibilities shall include, but are not LEED Representative as indicated on the project drawings. recycling service must be required to provide hauling assemblies. Exception: Dry sanding allowed subject to The system consists of five environmental categories limited to calculations collection and collation of all materials to be Owner's LEED Representative will provide Contractor and on-site party responsible for instructing workers and g • Y 9 � P p receipts outlining what percentage of weight was Owner approval of the following measures: Thlsdocument and the Ideas and designs Incorporated turned over to Owner's LEEDTM Representative for inclusion in the a ropTriate Subcontractors with blank Submittal Forms at the overseeing and documenting results of the herein,as an Instrument of professional service,is the containing 56 prerequisites and credits, and additional P PP diverted from landfill and where each materials was propertyof GRUSKIN ARCHITECTURE+DESIGN,P.C.,and categories for design innovation and regional priority. LEEDTM Application. LEED M Kick-Off Meetin The sam le LEEDTM Submittal Forms Construction Waste Management Plan for the ProjectIs not to- 9 9 9 P Y PP g P diverted to on a per bin basis specific to the project. without the written authorization ria ion for any other project required include: P P P J Full isolation of space under finishing. without the writtenauthorizationof GRUSKIN Each prerequisite and credit identifies the intent, TM ARCHITECTURE+DESIGN,P.C. LEED requirements need ongoing communication and reporting 2. Contactor shall provide on-site instruction of • Plastic protection sheeting is installed to provide air All Rights Reserved requirements and submittals to achieve its specific TM 4. Totals to date including: trash generated b weight to ensure subcontractor participation. Contractor shall participate . LEED Materials Submittal Form: Form to be appropriate separation, handling, and recycling, g� g y g sealing during the sanding. ©2015GruskinArchitecture+Design,P.C. goal. in the following meetings: provided to each subcontractor to record recycled and percentage of total; waste materials generated by P Y salvage, reuse, and return methods to be used by all Closure of all air system devices and ductwork. Kenneth A. C�rusldn AIA • Points are awarded for accomplishments in each content both post-industrial and post-consumer). This weight and percentage of total identified by salvaged TM ( p p ) parties at the appropriate stages of the Project. Sequencing of construction precludes the possibility of credit area, and are added together in the LEED • Pre-bid Webinar: Contractor shall attend a Pre-Bid q 9 p P Y Form will also provide the material cost and details Contractor shall conduct meetings, post signage, and far resale, salvaged for reuse, or recycled; cast AL 5421 MT 2537 Scorecard to arrive at a total score for the building. Webinar meeting. This meeting will be a half-hour Savin s• and percentage of disposal fees saved. contamination of other spaces with gypsum dust. AK 13167 NC 9961 TM about the recycled content. draft Subcontractor agreements to communicate the g ' P g P Four award levels of achievement are possible: orientation session to the Project's LEED goals, and TM 9 • Worker protection is provided. AR 3811 ND 1666 TM • LEED VOC Submittal Form: Form to be provided to goals of the waste reduction plan. AZ 39209 NE A-3547 Certified {40-49 points), Silver {50-59 points), (Gold the Contractors role in the LEED documentation each Subcontractor to record VOC content for all 5. For all material sent to a landfill for use as Alternative CA C-29898 NH 2796 (60-79 points) and Platinum (80 or more points) process, CO ARC-400347 NJ Al 09999 TM TM adhesives, sealants, paints and primers used on the 3. Contractor shall maintain current waste management Daily Cover (ADC), Contractor shall obtain a letter 7, Local Exhaust: Pollution sources can be directly CT 9613 NM 004168 • A LEED rating is awarded based on the US Green • LEED Kick-Off Meeting: Contractor shall attend a inside of the vapor barrier of the project. Adhesives from the landfill stating that the material was received exhausted to the outside. This may be done through DC ARC100723 W 5521 TM P P 1 records. Y 9 Building Council's review of the LEED TM Application LEED Kick-Off Meeting. This meeting will be a one- DE 0006261 NY 025528-1 NY and sealants include, but are not limited to multi- from the Project and was specifically used for ADO, an exhaust system already available in the building or FL AR91629 OK a4895 that is created by the owner, design and construction hour training Webinar for the construction team- This construction countertop, cabinet laminate including date of use. GA RA011075 OH 13761 4. The following categories shall be diverted from the g more often by a portable fan vented to the outside and team. meeting will be scheduled by the Owner's LEEDTM purpose Pr ry, g g HI AR 11489 (-OR 4899 TM glazing, duct work, fire caulk, acoustical, and plumbing landfill to a recycling facility: attached to the work site by flex duct- Depending on IA 05713 PA RA-015432-B Representative and the Contractors LEED adhesives and sealants. VOC limits are listed in theID AR-984459 PR 19965 Gonstrzlca�on fndaorArr Quality Management: the nature of the material and the location of the The following US Green Building Council (USGBC) document Coordination Manager, at a mutually agreed date and IL 001-019152 RI 2666 explains the LEED TV Green Building Rating System and provide time between Preconstruction Meeting and start of Clean dimensional wood, pallet wood, plywood, OSB, table provided in the Indoor Air Quality Management exhaust, special filtration of the exhaust may or may IN AR10400066 SC 6834 Section of this sheet- not be necessary. Any emissions to the outside must KS 4674 SD 11532 guidance to the achievement of each prerequisite and credit. (This construction. Attendance is required of Owner's and particleboard IAQ Requirements KY 5967 TN 101374 document may be obtained from the USGBG website at Project Manager, Contractor's Project Manager, Site TM . Ferrous and non-ferrous metals be in compliance with applicable regulations and LA 5734 TX 17680 LEED Materials Submittal Forms are required, where should be directed well away from intakes. Where ME ARC 2596 UT 5881358-0301 www.usgbc.org}: P t TM q Gypsum products, acoustical ceiling tile Contractor shall develop and implement an Indoor Air Quality y MD 11016 VF 2572 Superintendent, Contractors LEED Coordination applicable, for the following materials and products: Metal Studs, exhaust is not feasible, local re-circulation of air MA 10635 VA 0401 011223 TM Manager, and representatives of primary Framing, Doors and Glazing, Insulation Materials, Drywall, • Cardboard, paper (including blueprints), paper-based Management Plan during construction that meets or exceeds the MI 1301052379 WA 10344 • LEED Reference Guide for Green Interior Design g, gr ry through a portable air cleaner may be effective. The Subcontractors as applicable. Suspended Ceilings, Flooring, Paints & Wall coverings, Plywood, packaging minimum requirements of the SMACNA IAO Guidelines for MN 44326 WI 9900-005 and Construction (2009 Edition). 447-page document • Weekly LEED TV Calls: Contractor or Contractor's Concrete, Cabinets and Built-ins. . Paint Occupied Buildings under Construction, 2nd Edition 2007, hype of filter should be suitable for the material being MO A-2005029740 WV 3727 that includes the information on the Rating System TM controlled (e.g., charcoal or potassium permanganate MS 3860 WY C-1967 LEED Coordination Manager shall participate in a Glass bottles and late and porcelain ANSIJSMAGNA 008-2008 Chapter 3. These include: and expands to include green building issues, design TM The contractor shall provide the material cost {minus labor and { plate) P for many odors, a moderate to high efficiency filter for ProfesslonalSeal: approaches, calculation methodologies, references scheduled Weekly LEED Call to give an update on • Carpet and pad: 100% Reclamation PP � g• equipment) for each product within CSI Division 3 to 12 including dust). the construction progress toward the identified + Plastics, plastic film fiberglass solid 1• Mechanical Systems: All HVAC equipment must be definitions and case studies. TM Metals, Woods & Plastics, Thermal & Moisture Protection, Doors p ' g (solid) protected from collecting dust and contaminants that LEED construction credits. &Windows Finishes Specialties, and Furniture& Furnishings Doors windows frames relites hardware millwork P g P � g � � ' � IAQ Management Plan can be collected in the system and later be released. rM + Commissioning: Please refer to requirements for Y This project is targeted to earn a LEED Silver rating from the US Specific HVAC protection requirements apply to the TM coordination and meetings related to the For commissioning submittals, refer to Testing and Submittals in 5• Contractor shall protect materials to be recycled from p p q pp y TM TM Green Building Council. To achieve the LEED rating, applicant Commissioning Section on the LEED Prototype Green p Y return side, central filtration, and supply side of the At the LEED Kick-Off Meeting, Owners LEED Representative must satisfy all of the prerequisites and the number of commissioning process under the Commissioning g yp contamination b handling, storing and transporting projects ty p q TM Specifications. The contractor shall also provide submittals listed y g' g p g system. will provide a Draft IAO Management Plan to the Contractor. Prior credit points defined in the project LEED Scorecard (provided Section in LEED Prototype Green Specifications. Y under the Indoor Air Quality and Construction Waste Management materials in a manner that meets the requirements of to HVAC work, the Contractor shall submit 1 copy of thV for reference only}. the designated facility for acceptance. completed IAQ Management Plan to Owner's LEED Sections on this sheet. g Y P • All return system openings in or immediately adjacent Representative for approval. Contractor responsibilities to support these credits are outlined in to,the construction area should be sealed with plastic. Contractor shall require Sub-Contractors to complete the following 6. Contractor shall provide the necessary containers and the LEED Prototype Green Specifications and elsewhere in the p Y The Plan shall designate an on-site art or parties) responsible drawing set. The Owner's LEED TM Representative will provide Submittal Forms before start of work. bins to facilitate the waste management program. • When the system must be operational during 9 party ( P ) p construction temporary filters should be added where for instructing workers and overseeing and documenting results of training, support, and documentation tools to the contractor team Contractor shall also arrange for adequate collection the IAQ Management Plan for the Project. in achieving all identified credits. The training, support and and transportation to deliver recovered materials to the necessary (e.g- on grills to return air shaft). Filters Consultant: documentation tools that will be provided are outlined in these approved recycling center or processing facility. used during construction must have a minimum rating Once Owner's LEEDTM Representative has determined which of LEED Prototype Green Specifications. Recycling collection may be either source separated of MERV 8 and must receive frequent periodic the BMPs contained in the above draft Plan are acceptable, the or commingled or a combination of the two maintenance. Contractor shall submit, within 3 working days, a Final IAQ LEED-CI 2009 Scorecard . Replace the filters at the end of the project with MERV Management Plan. The Contractor shall distribute copies of the approaches. p p J IAQ Management Plan to the Job Site Foreman, each as 3s o Possible -. 13 filters (if units cannot accommodate MERV-13 Certified 40-49 Silver 50-59 Gold 60-79 Platinum so+ Materials Submittal Form filters, a minimum of MERV-8 must be specified). Subcontractor, the Owner and the Architect. 7. Contractor shall separate, store, and dispose of E Credits easy to achieve on all stores hazardous waste according to local regulations. Provide MERV 13 filters to process both return and At each scheduled Weekly LEED TM Call, the Contractor shall M Credits will be achieved on majority of stores,but may have site specific variance P"Jrct.ante: outside air that is to be delivered as supply air. provide a summary of IAO Management issues. ND Credits difficult to achieve or not applicable to stores IheM°jmtoami,pursuing wruf­aMunder c�r.<ndershipioRugyFdl•:nFitoornmtolDLignLErv,rrtmm.�reial r When the general system must remain operational, Imeri°rs Ra,ing3y.A-­X.Tnfu!fil!the nyuirnamis oftnis raogram,this,f-rustFc«nnpl<trdfr,r .Widirg 8. Recycling and waste bin areas shall be kept neat and material(i,e.dnwall,insulation.swel wait•etc)that you will be ftmtt hi„g to the project Wet-a.lied"odes arc mn indudcd.FlcazcrsLer to a,eVCX'Submitral Form for r<hi all pcts ftt are wet-applied atthep.mjmt site.l Clean and clearly marked in order to avoid the heaviest work areas should be dampered off or IAQ Submittals •• -• - -• 21 3 3 Possible-• 1714 >��.e511 tat!°Ithein�a,atitm "e,t�fin l °r > r.�fnmariaa�atd°«mr otherwise blocked if temporary imbalance of the return E M D E M D isuideltnnmed.For questions atwul e mp!eting this fomt.please r°:anct the S-1 cmtracicrt for the project. contamination of materials. e `� N on rereq torage on oecycSub-Contractor: The mechanical room should not be used to store air system does not create a greater problem. ,obNameandNumber 201 -0131 5 Credit 1 Site Selection Y P1 S8r Collection Rlables 0 1. To document the construction IAQ measures 5 ' 'ri`t`e,°'�""'" J i Select a LEED Certified Building5 Points n/a Credit 1.1 Tenant Space-Long Term Commitment 1 nate: lanufacturrr: 9. Contractor shall schedule visual inspections of ` implemented on the project, the Contractor shall Brownfield Redevelopment(1 Point) n/a Credit 1.2 Building ReuseMaintain Interior Non-Structural Componen 2 ,late lalcnaf(mi„nanasltrlalrormxleyuinment) a_..........___.--_.-.--_.__.-_.-.. construction or waste materials. Proposed dumpsters and recycling bins to identify potential provide a minimum of 40 photographs (10 each week Stormwater Design,Quantity Control(1 Point) Credit 2 Construction Waste Management • Diffusers, terminal units, and ducts may be adequately tairrlalSn"trtf�„h,,, contamination of materials. during construction) of construction measures in the VERIZON w Stonnwater Design,Quality Control(1 Point) 1 Divert 50%from Disposal 2 ,im,,u„„, 1LfC. protected in most cases where the above measures CL Heat Island Effect,Non-Roof 25%(1 Point) 1 Divert 75%from Disposal R IAQ management plan such as protection of ducts and ---------- -- are implemented. When the system is off for the I- Heat Island Effect,Non-Roof 50%(1 Point) nla Credit 3.1 Materials Reuse s L° i°'°`F�aneLExtr°"`a": - W CWM Plan on-site stored or installed absorptive materials. - yhh,> ,,fl.proje taih- duration of construction, diffusers and window unitsLLJ STORE Heat Island Effect,Roof(1 Point) 5 n/a Credit 3.2 Materials Reuse Furniture 1 m 1 ❑ lhataatCcheamannfactuerdxumenmu.:„ m, t- rr tG , J Mmi,L uraR;n<rm c,Y,. n a,, nna<,,khvacroei aama�a<i,t TM should also be sealed with plastic for further U Light Pollution Reduction(1 Point) Credit 4 Recycled Contenta Owners LEED Representative will provide a Draft Construction 2. The Contractor shall provide cut sheets of filtration 0Y Water Efficient Irrigation:Reduce b 50% 2 Points 1 Specify 10%P 1 2 rh.n L/ra «,. r „f.w. F mp m l a;m,,rn ,ns.,Mmi. TM protection. (LEED) o s v ( ) P Y d..n�,m° ofd rl dei , s'.1 r,m �f a Waste Management Plan at the Pre-Construction LEED Kick- media used during construction and installed Water Efficient Irrigation:No Potable Water Use or No Irrigation(2 Points) 1 Specify 2 Off Meeting. Within fifteen (15) working days after receipt of the • Ducts, diffusers, and window units should be immediately prior to occupancy with MERV values LJ Innovative Wastewater Technologies(2 Points) 41a R al 2 Reryrktlf: Notice to Proceed, or prior to waste removal, whichever occurs inspected upon completion of the work for the amount highlighted. °'0 4Cn m,er °;6 Water Use Reduction:30%Reduction(1 Point) nufa re ocally - (rn bmrdhwl d n,iwtal=lour., sooner, the Contractor shall prepare and submit one copy of the of deposited particulate present and should be Onsite Renewable Energy(2 Points) 1 xt ed and Manufactured Regionally ----- completed Construction Waste Management Plan to the Owner's cleaned where needed before initiating the HVAC ilia m cdmanufac,urndxumcntntionstatmrthtprrucnhigeofrroycledamtent. TM 3. If air handlers must be used during construction Other Quantifiable Environmental Performance(1 Point) R Id y Renewable Materials 1 LEED Representative for approval. g ('7 'r<. n«,are,.i,aM„pr�i�,,,,<,,,.9m,�,.<,nMne�ran).,ndpMr-;nttard,t«„r,-„ii;.r,�,p,.•<ean»,rr+.n!i�n;:,l System. 0 6 Credit 2 Development Density and Community Connectivity 6Certified Wood 1 Fr =�""n' rahh"'^A`!'f`r'p`ny'`'a-„`m""rt'p c=`ta ,"'<hl`F -'"' 'aL filtration media with a Minimum Efficiency Reporting lob Address: Ln 6 Credit 3.1 Alternative Transportation,Public Transportation Access(6 Points) 1. In the Plan designate an party(or parties} Value (MERV) of 8 must be used at each return air Washington Square Mail W nla Credit 3.2 Alternative Trans ortation,Bicycle Commuting(2 Point 10 BUM - 17 "�"^'°n' nna, responsible for instructing workers and overseeing and P > ••• - Possible '' p 9 9 2. Materials Handling: Protect construction materials grill. 9585 S.W. Washington Y Prereq 1 Minimum IAO Pe o n/a Credit 3.3 Alternative Transportation,Parking Availability(2 Points) E M D -------- documenting results of the Construction Waste from contamination and pollution from contact with Square Road Performance o Management Plan for the Project. construction dust, debris fumes, solvents and other 4. After construction ends and prior to occupancy, Z BEE •e -• 11 Y Prereq 2 Environmental Tobacco Smoke(ETS)Control PPortland, OR 97223 w w pollutants. replace filtration media with new Minimum Efficiency Space RO5-RO7 j E M D 1 Creditl Outdoor Air Delivery Monitoring 1 LF]S,QxhaaidwF.vn,;G,,naH Falagi,wa,Jh,mpmp.hn•.2fAp 2. Orbe the Owner's LEEDTM Representative has Reporting Value MERV 13 filtration media If units U Y Prereq 1 Water Use Reduction 1 Credit 2 Increased Ventilation 1 p g (MERV) A Credit 1 Water Use Reduction 1 Credit 3.1 Construction IAQ Management Plan,During Construction 1 determined which of the BMPs contained in the draft • Designate receiving/storage areas for incoming cannot accommodate MERV-13 filters, a minimum of Z 6 30%Reduction(6 Points) 11 Credit 3.2 Construction IAQ Management Plan,Before Occupancy Plan are acceptable, the Contractor shall submit, material to be delivered according to installation MERV-8 must be specified). DrawngTlde: U 2 35%Reduction(8 Points) n/a Option A:Flush out 1 within 5 working days, a Final Construction Waste schedule and to be placed convenient to work area in n/a 40%Reduction(11 Points) n/a Option B:IAQ Test Management Plan. order to minimize waste due to excessive materials Continued on Sheet LEEDZ LEED Prototype F 1 Credit 4.1 Low-Emitting Materials,Adhesives&Sealants 1 v, handling and misapplication. Z 'MME • Possible -• 37 1 Credit 4.2 Low-Emitting Materials,Paints&Coatings 1 VOC Submittal Form 0 3. The Contractor shall distribute copies of the U E M D 1 Credit 4.3 Low-Emitting Materials,Flooring Systems 1 PioJertlNarne: Construction Waste Management Plan to the Job Site Protect stored on-site or installed absorptive materials Green Specifications Y Prereq 1 Fundamental Building Systems Commissioning n/a Credit 4.4 Low-Emitting Materials,Composite Wood&Agrifiber Products 1 Tlw isojoet=rra spurwangccn.rtiuix uaRz,ur.iah lipinF en. drain.n,.tallksil.(LFIM)Ctmimeteial from moisture damage. cu1 tenurollaagSa9en6..Amaoigoalof this prognmmtoreduce th .premNofind. sir enamma:^dthater,odorous Foreman, each Subcontractor, the Owner and the i Y Prereq2 Minimum Ener Performance 1 Credit 4.5 Low-Emitting Materials,Furniture and Seating1 kr, n n root°ih ant,,taro tnb i g°rt snn ,. ,T°falnnl ,gufrem m ttdi, (n Energy g ,nigretn,Ilii.funnmrMtlxeogtp1e1n1HtrschptWuctlbat{iwe4appliedeilhfrtfhelmerl„t,vp,rchameroflhe • Hazardous wastes shall be separated, stored, and L3 Y Prereq 3 Fundamental Refrigerant Management 1 Credit 5 Indoor Chemical&Pollutant Source Control 1 prdrtf Architect before work commences on the site. disposed of according to local regulations. tZi o All is docur ew.rl a re o the the Volulil<(hgls,,t Lid fcs ro loci)timimtb,m a i nrywrt a n parr twn ' Credit 1.1 Optimize Energy PerformanceLighting Power 5 1 Credit 6.1 Controllability of Systems,Lighting 1 3 ftllsdacumem.l']esureC t tl�eF,aAoprnvcxlFrodwxsL.sttarprmiuct ,g vom.Ifm)a'tur^ttiropralucti, Drawn By: North 1 Reduce li htin power to 15%below the standard n/a Credit 6.2 Controllability of S stems,HVAC 1 Stec.d,p!axtrav lcacapyo°h fiakralSaLtya•,diyam hest(MSS)S)wththe VOCSubntwlForm rhewsrjs TM • Schedule delivery of materials to minimize the duration Arrow: g g P Y Y Y must txteVO(e,mtntingmmsperlitm. f!thL mformra, ,wm la1&4.nlhr>`,Sf)�pltawte,q.�tb VOLc,tent 4, Confirm to the Owners LEED Representative in A (� ° ( gc slyer ftm ih<r.,anufacnvcr Lk.m, ,iumeamn).1C.z.n,enirih nf.tmutinn .x shown. of on-site storage. cu 1 Reduce lighting power density to 20%below the standard 1 Credit 7.1 Thermal comfort,Design 1 writing that each Subcontractor has received a copy of checked By: Please 011 out the Information in the chart belowr � 1 Reduce lighting power density to 25%below the standard 1 Credit 7.2 Thermal Comfort,Employee Verification 1 the approved Construction Waste Management Plan. K 1 Reduce lighting power density to 30%below the standard 1 Credit 8.1 Daylight&Views,Daylight 75%of Spaces 1 Date Issued For ca 1 Reduce lighting power to 35%below the standard n/a Credit 8.1 Daylight&Views,Daylight 90%of Spaces 1 Sub Contractor: >„atr'iah 3. Scheduling for VOC Control: Schedule installation of Client: 12/24/15 9 gP YP TM Credit 1.2 Optimize Energy Performance- Controls 3 n/a Credit 8.2 Daylight&Views,Views for 90%of Spaces 1 Data: 5. Approval by the Owners LEED Representative and materials to minimize contamination of absorptive Landlord: 12/24/15 Iplan°nusingthe f ll wingVOC , ,ivlwAdh.�&ea;Seanm,•Primr. °r'',°, ° q'sn. the Owner of the Contractor's Construction Waste materials with VOCs, solvents, dust, etc. (For Permit: 12/24/15 1 Option A:Daylight responsive controls within 15fee#MiW Prnaucl Name: Type of Thepr use o �•oc tent in Allovahlctot Mona ement Plan will not relieve the Contractor of exam le, install car et after aintin has been J n/a Option B:Daylight responsive controls for 5_J I 0 5 1 Possible -• 6 pnarturaaiae:md,=«m=t m) Product: acne.. m, Contentln g/L g P P P g Bid: n/a Option ant sensors for 75% oa E M D �adh�i. "ISU3aheet ;ha,chattsm responsibility for adequate and continuing control of completed, since carpet can absorb VOCs released � P Occupancy sealant. in wiR,t'OCronrem) n.�i nt, P tY q g P p Construction: w Credit 1.3 Optimize Energy Pertorman ton or ) 10 Credit 1.1 Innovation in Design pollutants and other environmental protection while the paint dries).All dry furnishings and materials RewSlonIssue: 5 Option A:Equipment Effi ' an rots(5-10 Points) 1 Credit 1.2 Occupant Recycling VP measures Specified. (such as carpet, floor tile, acoustical tile, textiles, office No. Date Description C3 n/a Option B:ReduSIplkn., pXTy(: (5-10 Points) 1 Credit 1.3 Toxic Material Source Reduction 5 furniture, wood shelving, etc.} shall be allowed to "air- IL Credit 1.4 Optimize P o c q aruipmertt and Appliances 4 1 Credit 1.4 Green Housekeeping CWM Submittals out" or pre-condition prior to installation. Reduce O 1 70%of En Ii • I equipment is Energy Star rated 1 Credit 1.5 Green Educational Program 0 1 0 o ne Igible equipment is Energy Star rated 1 Credit 1.6 Hopeline Program _ exposure t0 VOCs as fOIIOwS: Z 1 erg tar eligible equipment is Energy Star rated 1 Credit 2 LEED Accredited Professional 1War Contractor shall follow the specified method for monitoring and Cl) 1 90 Energy Star eligible equipment is Energy Star rated ❑ documenting the CWM Plan and submit a weekly report at the • Containers of wet products should be kept closed as Q 3 5 C dit 2 anted commissioning 5 Bum • • e Points weekly LEEDTM call, including the following: much as possible. Crell 3 Energy Use,Measurement&Payment Accountability 5 E M D Vttrotarr: rat°: • Waste materials that can release odor or dust should C) Install Sub-Metering Equipment(2 Points) 1 Credit 1.1 Regional Priority 1 ...-................------__._......_..__.--._..__..-....-._.._ __-.__..._._.-...___. 1. The amount (in tons or cubic yards of material) of be covered or sealed. u, 5 Tenant Pays for Energy(3 Points) 1 Credit 1.2 Regional Priority 1 -Jni<di,r.drr�!aaim ,u,Fw-ithn,he nt<ii� fear+a, material landfilled from the Project, the location of the • .-r s Applying a sealer may control a surface that is a if),,u ha,'e my g,r:stior,%please contact Roe conte nm.Thank you fcreomp-ging with the I.FXJ)re It irtmenLs and nl OR Energy Use,Measurement&Payment Accountability(5 Points) 1 Credit 1.3 Regional Priority 1 contnb,mngtothccnvirmmarttalgealsofth:spropct Receiving Facility, the total amount of tip fees paid at persistent odor source. Zs credo a Green Power 5 1 Credit 1.4 Regional Priority 1 the landfill, and the total disposal cost including 0 H . W transportation costs, container rental costs,taxes, etc. o - Include manifests, weight tickets, receipt, and 4. Inspection: Conduct regular inspection and maintenance of indoor air quality measures including w 3 invoices. ventilation system protection. Take photographs to 3 G? Drawing Number. X A 2. The amount (in tons or cubic yards of material) and document protection measures (see IAO Submittals X w on this sheet). Ductwork and appurtenances should Z_ type of waste materials salvaged for sale, salvaged for be inspected u completion of the work for the E3 on reuse and recycled. Provide the date removed from p p LK o the jobsite, the location of the Receiving Facility, the amount of deposited particulate present and cleaned where needed. LEEDI ,Lc) Cd 30 OF 31 Substitutions Closeout Checklists will be provided by the CxP to the occupancy, equipment, seasonal requirements, design Cor;'bnuOd from Sheet LEED? Contractor at the Commissioning Kick-off Meeting. or other site conditions; performance of these tests, Substitutions may impact credit achievement. Contractor Within two weeks of Commissioning completion (see below), The Checklists are completed by the Contractor and including participation of Commissioning Team shall identify which LEED credit strategies may be affected by TM Contractor or Contractor's LEEDTM Coordination Manager shall verified by the Commissioning Provider and members, remains the Contractor's responsibility the proposed substitution. All substitutions affecting LEED TM TM provide final documentation for LEED Application Closeout to Commissioning Tester. No sample of identical or near- regardless of timing. Low-VOC Product Requirements credits must be approved by Owner's LEED Representative. Owner's LEEDTM Representative. This documentation shall identical items is allowed. Prefunctional Checklists do GRUSKIN include all Materia! Tracking Forms, copies of CWM and IAQ not replace manufacturers' recommended startuARCHITECTURE + DESIGN.PC. Wherever noted on the drawings, substitutions shall be plans copies of waste reports and tipping receipts and P P 6. Retesting due to equipment not being ready for 1. Paints & Adhesives: All adhesives, sealants, paints accompanied with the applicable LEEDTM Submittal Form and checklists, regardless of apparent redundancy. Functional Testing will be at the Contractor's expense. 294 Morris Avenue Springfield,NJ 07081 and primers within the vapor barrier shall have law product information (required an the form} and provided to photographs of CWM and IAQ procedures as outlined in the Tel: 973.376.441 1 Fax: 973.376.8989 emissions of Volatile Organic Compounds e to TM. LEED Prototype Green Specifications. These expenses may include, but are not limited to, www.GruskinGroap.com NJ REG 0100-9869-14 9 P ) Owners LEED Representative for approval before product can 3. Provide complete copies of the following Prefunctional CxT time and travel expenses. with Maximum limits per the Table below. be used on site. checklists to the Owner, Commissioning Provider, and fiisdocument and the Ideas and designs Incorporated 2. Carpet Systems: Shall meet or exceed the Commissioning: Commissioning Tester at least 5 business days before herein,as an Instrument of professional service,is the P y The performance criteria of the substitute material shall be equal g y propertyof GRUSKIN ARCHITECTURE+DESIGN,P.C.,and requirements of the Carpet and Rug Institute's Green or superior to the LEED TM performance criteria as specified on this Functional Testing date: Isnottobeused lnwholeorinpartforany other project without the written authorization of GRUSKIN Label Plus Indoor Air Quality Test Program. sheet and on other drawings in this set. Cx Requirements Cx Test Equipment ARCHITECTURE+DESIGN,P.C. HVAC Units& HVAC Controls An Rights Reserved 3. Hard Surface Flooring Systems: Shall meet the Contractor shall notify Architect, Construction PM and Owner's Commissioning encompasses and coordinates the traditionally + Plumbing&Water Heaters Contractor will provide test equipment as necessary for start-up ©2015GruskinArchitecture+Design,P.C. requirements of the FloorScore standard. LEEDTM Representative immediately of any proposed separate functions of system documentation, equipment startup, + Lighting & Lighting Controls substitutions for paints, adhesives and sealants which do not meet g g g g and testing of electrical, mechanical and plumbing equipment. Kemeth A. Gruskln AIA TM P control system calibration,testing and balancing, training, and + Test and Balance Report Test equipment shall be of sufficient quality and accuracy to test AL 5421 MT 2537 LEED VOC requirements (See VOC limits in table provided in performance testing. Commissioning during the construction Testandfa measure system performance quality with the following the Indoor Air QualityManagement Section of this sheet). The y P g AK 1311 NC 9961 g , Tnn } phase is intended to achieve the following specific objectives: 4. Perform commissioning Functional Test procedures tolerances: AR 3811 ND 1666 Architect, Construction PM or Owners LEED Representative AZ 39209 NE A-3547 can assist Contractor with finding alternate compliant products. under the GxT's direction. Functional Tests{FT} are 9 P p 1. Verify that applicable equipment and systems are 1. Tem CA C-29898 NH 2796 Temperature sensors and digital thermometers shall documented tests of the dynamic operation of P 9 CO ARC-400347 NJ Al 09999 installed according to the manufacturer's equipment and systems with the goal of verifying that have an accuracy of 0.9°F and a resolution of+/- CT 9613 NM 004168 recommendations and to industry accepted minimum the Acceptance Criteria are met. Test requirements 0.1°F. Sensors and thermometers shall have been DC ARC100723 NV 5521 standards and that the receive adequate operational P q DE 0006261 NY 025528-1 NY y q P are included in the construction documents. Test calibrated within the last year. FL AR91629 OK 04895 VOC Limits for LEED-Cl 200 checkout by installing Subcontractors. results are documented b the Commissioning Tester. GA AR 11489 OH 13761 y g HI AR 11489 OR 4899 Test procedures are completed by the Contractor and 2. Pressure sensors shall have an accuracy of +1- 2.0% IA 05713 PA RA-015432-B 2. Verify the performance of applicable equipment and Subcontractors. The commissioning team will of the value range being measured (not full range of ID AR-984459 PR 19965 For any products that applied within the interior vapor barrier of the building, the VOC content{measured in gramslliter} 9 IL 001-019152 RI 2666 systems meet the Owner's Acceptance Criteria, as complete the Functional Tests. meter) and shall have been calibrated within the last IN AR10400066 SC 6834 must be less than the established limits stated below. All VOC limits are in g/L less water unless noted otherwise. documented through Prefunctional Checklists and p KS 4674 SD 11532 year. KY 5967 TN 101374 Functional Tests. 5. Functional Testing will be scheduled by the Contractor LA 5734 TX 17680 SCAQMD Rule 1168 2005)Adhesive and Sealant 3. Equipment shall be calibrated according to the ME ARC 2596 LIT 5881358-0301 ( Application Green Seal GS-36(2000)Commercial Adhesives to Occur following turnover to the owner and before9 MD 11016 VT 2572 0 3. Successful completion of the commissioning process open doors date. The following Functional Tests will manufacturer's recommended interval within the last MA 10635 VA 0401 011223 Architectural Applications VOC Limit g1L Aerosol Adhesives VOC Limit to is required to obtain a LEEDTM CI green building MI 1301052379 WA 10344 p Indoor Carpet Adhesives 50 General Purpose Mist Spray 65% be performed: year, or when dropped or damaged, whichever is more MN 44326 WI 9900-005 o certification. recent. Calibration tags shall be affixed or certificates MO A-2005029740 WV 3727 Carpet Pad Adhesives 50 General Purpose Web Spray 55% MS 3860 WY C-1967 • HVAC Units& HVAC Controls readily available. Wood Flooring Adhesives 100 Special Purpose Aerosol Adhesive 70% CommissioningActivities will be led b the CommissioningProfessional Seal: Rubber Floor Adhesives 60 y • Air Distribution Equipment&Air Balance Provider (CxP) and on-site Commissioning Tester (CxT). • Plumbing&Water Heaters 4. For products in which proprietary test equipment is Subfloor Adhesives 50 SCAQMD Rule'l 168,Adhesive and Sealant Application .ssLighting & Lighting Controls needed for a Functional Test, product manufacturer Ceramic Tile Adhesives 65 The following systems, assemblies, equipment, and components Sealants VOC Limit IL will be commissioned: shall furnish test equipment, demonstrate its use, and VCT & Asphalt Adhesives 50 6. Acceptance by each commissioning team member of D Architectural 250 wall & Panel Adhesives 50 each Prefunctional Checklist and each Functional Test assist Commissioning Provider in commissioning Cove Base Adhesives 50 • HVAC Units process. Proprietary test equipment shall become Green Seal GS-11 (1993) Paints + Air Distribution Equipment&Air Balance shall be indicated by signature and date. Multipurpose construction Adhesives 70 properly of the Owner upon completion of Architectural Paints & Primers VOC LimitIL HVAC Controls Structural Glazing Adhesives 100 g Commissioning. Interior Flat Coating �or Primer 50 Dx Unit Serving the Telco Room 7. As-built or"red line" drawings will be made available Interior Non-Flat Coating or Primer 150 Exhaust Fans for MEP systems and controls at the job site on the Substrate Specific Applications VOC Limit gIL 0 Plumbing Piping day that Functional Testing is scheduled. Metal to Metal 30 Green Seal GC=03(2"0 edition, 1997)Anti-Corrosive Paints Plumbing Fixtures Plastic Foams 50 Water Heater B. Commissioningof Mechanical and Plumbing Systems- Porous Paints VOC Limit /L Lighting Fixtures &Controls g y consultant: Porous Material (except wood 50 Anti-Corrosive)Anti-Rust Paint 250 0 For commissioning process activities relating to the Wood 30 Where these terms are used together or separately, they shall heating, ventilating, air conditioning, and domestic hot Fiberglass 80 SCAQMD Rule 1113 (2004)Architectural Coatings mean "as-built" systems, assemblies, equipment, and water systems, assemblies, equipment, and Architectural Finishes & Coatings VOC Limit IL components. components: Sealant Primers VOC Limit IL Clear Wood Finish: Lacquer 550 Architectural Non Parous 250 All substitutions affecting the identified systems that will be Final Prefunctional Checklists. Complete and submit Clear Wood Finish: Sanding Sealer 350 P commissioned in the project must be reviewed by the to the Owner, Commissioning Provider and Architectural Porous 775 Clear Wood Finish: Varnish 350 Commissioning Tester and Commissioning Provider before being Commissioning Tester of the Prefunctional Other 750 Clear Brushingg a co Lacquer 680 approved. copy Floor Coatings 100 Checklists at least 5 business days before Functional (XI date. Specialty Applications VOC Limit Sealers and Undercoaters 200 Cx Coordination 1L Shellac: Glean 730 Start Up Documentation. Provide startup checklists PVC Welding 510 Assign a Representative with expertise and authority to act on and operations and maintenance documentation from Shellac: Pigmented 550 P Job Name and Number: cu behalf of the Contractor and schedule Subcontractors to the equipment manufacturer or mechanical 2015-0131 CPVC Welding 490 Stain 250 - - articr ate In and perform commissioning process activities Proposed J 325 participate P g P Subcontractor for the packaged rooftop units and DX i ABS Welding _ Concrete Curing Compounds 350 including, but not limited to,the following: system and controls with the Prefunctional Checklists. i- Plastic Cement Welding 250 Ja ansf Faux Finishing Coatings 350 WAdhesive Primer for Plastic 550 Magnesite Cement Coatings 450 1. Designate commissioning team members to complete Test and Balance Report. Submit a copy of the Test V E R I ZO N a- Contact Adhesive 80 Pigmented Lacquer 550 the Prefunctional Checklists and participate in the and Balance Subcontractor's report including outdoor w Special Purpose Contact Adhesive 250 Waterproofing Sealers 250 Functional Tests. These team members shall be air flows 5 days before Functional Testing date. STORE Structural Wood Member Adhesive 140 Waterproofing Concrete/Masonry 400 individuals, each having authority to act on behalf of gCommissioning of Lighting Systems-For Sheet Applied Rubber Linin 850 Sealers the entity he or she represents, explicitly organized to . (LEED) 13 To & Trim Adhesive 250 Wood Preservatives 350 implement the commissioning process through commissioning process activities relating to the A Low-Solids Coatings 120 coordinated actions. The commissioning team lighting systems, assemblies, equipment, and members shall be as follows: components. c Contractor's Electrical Representative + Final Prefunctional Checklists. Complete and submit This table excludes adhesives and sealants integral to the water-proofing system or that are not building Contractor's Mechanical Representative to the Owner, Commissioning Provider and Job Address: torelated. 0 Contractor's Plumbing Representative Commissioning Tester a copy of Prefunctional Washington Square Mail N • Contractor's Test and Balance Representative Checklists at least 5 days before Functional Testing 9585 S.W. Washington • Contractor's Controls Representative date. M Contractors Project Site Superintendent Square Road Z Owner's Project Manager Portland OR 97223 Owner's Commissioning Provider CxP Provide start up and operations and maintenance • g (CxP) Space R05-1307 + Owner's Commissioning Tester (CxT) documentation from the equipment manufacturer or A electrical Subcontractor for the lighting system and Z2. Commissioning team members appointed by the controls with the Prefunctional Checklists at least 5 DravdngTitle: U Contractor shall attend commissioning meetings. days before Functional Testing slate. Attend and participate in the following Commissioning Z team meeting (may take place via telephone): Corrective Action and Retesting LEED Prototype Green Specifications • Commissioning Kick-off Meeting: This meeting 1. Contractor shall cooperate with the CxP and CxT for CU provides an overview of the commissioning process, resolution of issues recorded in "Issues Log." The Lo submittals and schedule will be reviewed.The Issues Log is a dynamic document that the CxT uses 3 Commissioning Provider will provide copies of the to track any design or performance deficiencies Drawn By North < Prefunctional Checklists for review at the meetingarom. A identified during document review and Functional JL based on the Acceptance criteria. The Acceptance Testing for presentation to the Owner. checked By . Criteria is a document that is assembled by the CxP KG o and specifies the acceptable performance of testable Date Issued For systems from which the Prefunctional Checklists and 2. Evaluate performance deficiencies identified during Client: 12/24/15 Functional Tests are derived. Functional Testing and, in collaboration with entity Landlord: 12/24/15 responsible for system and equipment installation, Permit: 12/24/15 J 3. Integrate and coordinate commissioning process recommend corrective action. Upon failure of any Bid: activities with construction schedule. Include a 1-day Functional Test item, the Contractor shall correct Construction: activity in the construction schedule called Building Revision Issue: w deficiencies in accordance with the applicable contract Commissioning which shall occur following building requirements. The item shall then be retested until the No. Date Description o turnover to the Owner and before open doors date. Z This activity shall include Functional Test procedures. Functional Test has been completed with no errors. o Functional Testing shall begin after Prefunctional L 3. In some systems, maladjustments, misapplied Checklists are completed, submitted and approved by equipment, and deficient performance under varying r=iJ the Owner's Project Manager, Commissioning Q loads will result in additional work being required to 3 Provider, and Commissioning Tester. commission systems.The Contractor will complete CD work under direction of the Owner with input from the Cx Testing and Submittals to CxT and CxP. CD N 1. Prefunctional Checklists and Functional Tests shall be Z 4. All members will have input and opportunity to discuss completed by the commissioning team under direct the work and resolve problems, and the Owner will W guidance of the Commissioning Provider and have final authority on necessary work to be done to L3 Commissioning Tester. achieve performance. Complete corrective work to w A permit completion of commissioning processes; costs XA 2. The Contractor and their Subcontractors will complete incurred to solve problems in an expeditious manner DrawnngNumber X J the Prefunctional Checklists for CxT and CxP approval will be the Contractor's responsibility. Z as work is completed. Prefunctional Checklists (PFC) W o are written checklists that include checks and tests 5. Tests may need to be performed later, after substantialLEED 2 W1 in prerequisite to the equipment's Functional Test. I o completion or open door day, due to partial cu 31 OF 31