Loading...
Report PHYSICAL DATA & SPECIFICATIONS GF1 R92P SERIES GF3 GF2 Physical Data and Specifications—Upflow Models U.S.and Canadian Models _ _ _ MODEL NUMBERS R92PA0401317MSA R92PA0601317MSA R92PA0701317MSA R92PA085121MSA R92PA1001521MSAg92PA1151524MSA HIGH FIRE INPUT BTU/HR[kW] D 42,000[12.31] 56,000[16.41] 70,0 .50] 84,000[24.61] 98,000[38.71] 11 , . 2] HEATING CAPACITY BTU/HR[kW] 39,060[11.45] 52,080[15.26] 65,100[19.67] 78,120[22.89] 91,140[36.00] 104,160[30.52] HIGH ALTITUDE OUTPUT 35,154[10.30] 46,872[13.74] 58,590[17.17] 70,308[26.60] 82,026[24.03] 93,744[27.47] 10%DERATE[kW]a BLOWER(DxW) 11x7 11x8 11x8 11x10 11x10 11x11 [mm] [279 x 178] [279 x 203] [279 x 203] [279 x 254] [279 x 254] [279 x 279] MOTOR H.P.[W]— 1/4[187]-4-PSC 1/2[373]-4-PSC 1/2[373]-4-PSC 3/4[559]-4-PSC 3/4[559]-4-PSC 3/4[559]-4-PSC TYPE MOTOR FULL LOAD AMPS 4.0 6.8 6.8 8.3 8.3 8.3 HEATING SPEED MED-HIGH MED-HIGH MED-HIGH MED-HIGH MED-HIGH MED-HIGH COOLING SPEED HIGH HIGH HIGH HIGH HIGH HIGH MINIMUM EXT.STATIC .18[.045] .20[.050] .23[.057] .28[070] .28[.070] .28[.070] PRESSURE(IN.W.C.)[kPa] MAXIMUM EXT.STATIC 0.8[0.19] 0.8[0.19] 0.8[0.19] 0.8[0.19] 0.8[0.19] 0.8[0.19] PRESSURE(IN.W.C.)[kPa] HEATING CFM @.2"[.049 kPa] 1049[494] 1139[537] 1211 [571] 1704[804] 1748[825] 1750[825] W.C.E.S.P.[Us] COOLING CFM @.5"[.124 kPa] 1121 [528] 1232[581] 1318[622] 1742[822] 1782[841] 1934[912] W.C.E.S.P.[Us] TEMPERATURE RISE-HIGH FIRE 25-55 35-65 40-70 35-65 35-65 45-75 RANGE IN DEGREES°F[°C] [14-31] [19-36] [22-39] [19-36] [19-36] [25-42] RETURN AIR CABINETS(OPT.) C17B C17B C17B C21B C21B C24B RXGR- (2)12"x 16" (2)12"x 16" (2)12"x 16" (2)12"x 20" (2)12"x 20" (2)24"x 16" FILTER SIZE [305 x 406] [305 x 406] [305 x 406] [305 x 508] [305 x 508] [609 x 406] [mm] APPROX.SHIPPING WEIGHT [56] 128[58] t\ 132[60] 147.5[67] 152[69] 165[75] (LBS.)[kg] AFUE OO 92.00% 92.00% 92.00% 92.00% 92.00% 92.00% NOTES: All models are 115V,60HZ,1 phase Gas connection size for all models is 1/2"[13 mm]N.P.T. O Installation instructions for high altitude derate. ®Canadian installations only. OO In accordance with D.O.E.test procedures. *S=Standard Models NOTE:Standard model complies with California low nox requirements. GF3 furnace [ ]Designates Metric Conversions in attic 4 RELY ON RUUD.Ul A DIMENSIONAL DATA • R 9 2 P SERIES FRONT BOTTOM TOP A __ 121/32" 15/e„ [42 mm]1 [41 mm] [�B �] g OPTIONAL OPTIONAL ♦ ' s/e„ VENT OUTLET I vie COMBUSTION AIR [16 mm] Ili-5/e" KNOCKOUT rit [8 mm] INLET KNOCKOUT [16 mmj A v _. .. • et SUPPLY AIR O . . 1927/32" A 247/8" [504 mm] [631 mm] 261/4" A [667 mm] 24" 237/32" RETURN o [633 mm] [590 mm] yy AIR 1925/32" [502 mm] i /._ I [864 mm] : $ 9/32" 1 1 [17 mm] `/ 0. 13/4" 121/32" C f[1435/ [45 mm] [42 mm] LI ~-A ► 4 263/16"[665 mm] 4 253/16"[656 mm] ► 4 295/8"[752 mm] ► 4 257/16"[646 mm] 4 281/16"[713 mm] f 236/16"[593 mm] OPTIONAL CONDENSATE OPTIONAL —► 4_11/8" [28" 1927/32"[504 mm] 6/e" 4 225/1&'[567 mm] DRAIN(DOWNFLOW) CONDENSATE DRAIN [16 mm] v • ♦ 4 (DOWNFLOW) �.. +• • OPTIONAL TRAP • _ 2231/32" LOCATION 1/1'; 1 [583 mmj . (HORIZONTAL) ' I OPTIONAL •-'— GAS CONNECTION GAS • 321/8" - �• TRAP LOCATION CONNECTION •�I [835 mm] " (HORIZONTAL) I OPTIONAL TRAP _ 291/16" I� 2313/18 OPTIONAL COMBUSTION • LOCATION 1 [738 mm] [605 mm] VENT LOCATION 29/32" (HORIZONTAL) [738 mm] t 0,,—.7— OPTIONAL CONDENSATE • -- DRAIN(UPFLOW) t3PTiONAL�JENT 261/8" r AIR INLET 171/2" [583 mm]]] 177/16" r 1 1 [445 mm] [443 mm] —OPTIONAL LOW VOLTAGE I CONDENSATE DRAIN ••• A 263/16" v WIRING (UPFLOV� I 181/a" 322/32" 14"[665 mm] C).1.----"--OPTIONAL v��� [356 mm] ELECTRICAL CONNECTION ' [461 mm] [829 mm] \ � LINE VOLTAGE -OPTIONAL LINE VOLTAGE WIRING IELELCIRLOICWAVL CONNECTION OLTAGE • L J 3 . . . . . . . 1111111 • '- 23"[584 mm] ►r 228/8"575 mm] 248/16"[[614 mm] 8" 111/32" 11" 8" 265/16"[668 mm] [203 mm] [280 mm] [279 mm] [203 mm] RIGHT SIDE LEFT SIDE GF3 UNIT DIMENSIONS (CLEARANCE TO COMBUSTIBLES) MODEL LEFT MINIMUM CLEARANCE(IN.)[mm] SHIP WGTS. FLANGE DIMENSIONS R92P SIDE RIGHT BACK TOP FRONT VENT (LBS.)[kg] A B C SIDE 040 0 0 0 1 [25] 2[51] 0 123.5[56] 171/2[445] 1617/64[413] _ 1613/64[412] 060 0 0 0 1 [25] 2[51] 0 128 [58] 171/2[445] 1617/64[413] 1613/64[412] ......... .. 070 0 0 0 1 [25] 2[51] 0 132 [60] 171/2[445] 1617/64[413] 1613/64[412] 085 0 0 0 1 [25] 2[51] 0 147.5[67] 21 [533] 1949/64[502] 1945/64[500] 100 0 0 0 1 [25] 2[51] 0 152 [69] 21 [533] 1949/64[502] 1945/64[500] ._ . 115 0 0 0 1 [25] 2[51] 0 165 [75] 241/2[662] 2317/64[591] 2313/64[589] *A service clearance of at least 24"is recommended in front of all furnaces [ I Designates Metric Conversions Supply and return depicted as upflow configuration. Flange configuration will vary depending on installation orientation. GF1 GF2 f.1 6 RELY ON RUUD. BLOWER PERFORMANCE DATA R92P SERIES • BLOWER MOTOR BLOWER CFM[Lis]AIR DELIVERY MODEL SIZE H.P. SPEED EXTERNAL STATIC PRESSURE INCHES WATER COLUMN[kPa] [mm] [W] 0.1 [.02] 0.2[.05] 0.3[.07] 0.4[.10] 0.5[.12] 0.6[.151 0.7[.171 0.8[.191 LOW 732 [345] 695[328] 669[316] 639[301] 605[285] 547[258] 512[242] 487[230] R92PA 11 x 7 1/4 MED-LO 875 [413] 845[399] 820[387] 792[374] 766[361] 726 342 659[311] 605[286] 0401317 [279 x 178] [187] MED-111* 1073 1506] 1049[495] 1(04 1474] 97514 '041448] 9OtI 43" 0081 7,9$1376] HIGH 1279 [603] 4239.0584] 1213[572] X1174[5541 1121 [529] 1069 1033[487] 980`[46 „ LOW 830 [392] 793[374] 755[356] 705[333] 654[308] 599[283] 544[257] 496[234] R92PA 11 x 8 1/2 MED-LO 940 [443] 908[428] 875[413] 821 [387] 766[361] 710[333] 653[308] 584[275] 0601317 [279 x 203] [373] MED4II* 1168 1551] 1139[5371al:,[523] 1060 1Qj01476 , 9421444] '48.. '121 802[378] HIGH 1421 [670] 1385165 3] 1" " ti36) 129116091`i4 k„ 8 ,: 1147 15411 fili a` >a ;976[460] LOW 852 [402] 827[390] 802[378] 752[355] 701 [331] 662[312] 623[294] 580[274] R92PA 11 x 8 1/2 MED-LO 986 [465] 955[450] 923[435] 883[417] 843[398] 790[373] 737[348] 686[324] 0701317 [279 x 203] [373] MED-HI* 1238 [584] "12I ,...)1,83[558] 11: 1094 15181 1036[489) 9781461] 89714231 HIGH 1493 [704] 145216x6 1 0[665] 1 1318.[6621 129' 1593) 1015641 1084[511] LOW 1313 [619] 1275[601] 1236[583] 1221 [576] 1184[558] 1141 [538] 1098[518] 1053[497] R92PA 11 x 10 3/4 MED-LO 1488 [702] 1452[685] 1415[667] 1384[653] " 1328[626] 1279[603] 1229[580] 1170[552] 0851521 [279 x 254] [559] MED-HI* 1732 [817] 17041804] 16761791] '163017691 1579[745] 1498[7071' 1417[668] [6331 HIGH 1983 [935] 1929[910] 187418841 1610[854] 1742[RA 103 1784] '15831747L1477 16971 LOW 1329 [627] 1313[619] 1296 611] 1260[594] 1224[577] 1171 [552] 1117[527] 1049[495] R92PA 11 x 10 3/4 MED-LO 1535 [724] 1498[707] 1461 [689] 1422[671] 1382[652] 1325[625] 1268[598] 1203[567] 1001521 [279 x 254] [559] MED-HI* 1796 [847] '17481825] 17 I +�4»�s" .,[781] 16121760) .1! 17251 14601 ; 1646)�r HIGH 2019 [952] 1981 1925] 1 1 .' [869], 1782[841] 168717 1 1592[7511 14 [702)"% LOW 1249 [589] 1234[582] 1219[575] 1183[558] 1146[541] 1112[525] 1078[508] 1017[480] R92PA 11 x 11 3/4 MED-LO 1440 [679] 1429[674] 1417[668] 1381 [651] 1344[634] 1313[619] 1281 [604] 1221 [576] 1151524 [279 x 279] [559] MED-HI* 1770 [835] 17501 1730101M 16961800) =168217841 "1611 [7601 :155911351_'4 [690] HIGH 2123[1001] 2077 j•�.+I) „:6,1[95 „;;'1983[93 ) 19341912] ']856[875] 17771 6 j" 1995 1785] *Factory setting for heat all grey cells are valid heating settings.Do not use speed tabs and/or static pressure which do not fall into the grey cells on this table. NOTE:Unit tested without filters. [ ]Designates Metric Conversions RELY ON RUUD.T' 7 General Data/Electrical Data AC3 ACI ', RA13 Series AC2 Physical Data PHYSICAL DATA ` Model No. RA1318A RA1324A RA1330A RA1336A RA1342A RA1348A RA1360A ) Nominal Tonnage 1.5 2.0 2.5 . 3.5 4.0 Valve Connections Liquid Line 0.D.-in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Suction Line 0.0.-in. 3/4 3/4 3/4 3/4 7/8 7/8 7/8 Refrigerant(R410A)furnished oz.' 50 60 72 86 105 106 148 Compressor Type Scroll Outdoor Coil Net face area-Outer Coil 5.9 9.1 9.1 12.1 14.2 14.8 18.8 Net face area-Inner Coil - - - - - Tube diameter-in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Number of rows 1 1 1 1 1 1 1 Fins per inch 22 18 22 22 22 22 22 Outdoor Fan Diameter-in. 20 20 20 20 20 24 26 Number of blades 2 2 3 3 2 3 2 Motor hp 1/8 1/8 1/4 1/4 1/8 1/6 1/5 CFM 2038 2325 2795 2900 2465 4145 3870 RPM 1075 1075 1075 1075 1075 850 820 watts 144 137 189 186 175 279 233 Shipping weight-lbs. 127 129 140 164 195 202 235 Operating weight-lbs. 120 122 133 157 188 195 228 Electrical Data Line Voltage Data(Volts-Phase-Hz) 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 Maximum overcurrent protection(amps)2 20 25 30 35 40 50 60 Minimum circuit ampacity3 13 15 18 23 24 29 35 Compressor Rated load amps 9.7 11.2 12.8 16.7 17.9 21.8 26.4 Locked rotor amps 46 60.8 64 83.9 112 117 134 Condenser Fan Motor Full load amps 0.7 0.7 1.3 1.3 0.7 1 1.2 Locked rotor amps 1.3 1.3 2.5 2.6 1.3 2 2 Line Voltage Data (Volts-Phase-Hz) - - - 208/230-3-60 208/230-3-60 208/230-3-60 208/230-3-60 Maximum overcurrent protection(amps)2 - - - 20 30 30 35 Minimum circuit ampacity3 - - - 15 18 19 22 Compressor Rated load amps - - - 10.4 13.2 13.7 16 Locked rotor amps - - - 73 88 83.1 110 Condenser Fan Motor Full load amps - - - 1.3 0.7 1 1.3 Locked rotor amps - - - 2.6 1.3 2.2 2.0 Line Voltage Data (Volts-Phase-Hz) - - - 480-3-60 480-3-60 480-3-60 480-3-60 Maximum overcurrent protection(amps)2 - - - 15 15 15 15 Minimum circuit ampacity3 - - - 8 8 9 11 Compressor Rated load amps - - - 5.8 6.0 6.2 7.8 Locked rotor amps - - - 38 44 41 52 Condenser Fan Motor Full load amps - - - .6 .3 .6 .6 Locked rotor amps l - - - 2.5 .9 L 1.6 1.1 1Refrigerant charge sufficient for 15 ft.length of refrigerant lines.For longer line set requirements see the installation instructions for information about set length and additional refrigerant charge required. 2HACR type circuit breaker of fuse. 3Refer to National Electrical Code manual to determine wire,fuse and disconnect size requirements. Tf.1 8 RELY ON RUUD. Unit Dimensions RA13 Series Unit Dimensions OPERATING SHIPPING MODEL N0. H(Height) L(Length) W(Width) H(Height) L(Length) W(Width) INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm RA1318 27 685 29.75 755 29.75 755 28.75 730 32.38 822 32.38 822 RA1324 25 635 29.75 755 29.75 755 26.75 679 32.38 822 32.38 822 RA1330 25 635 29.75 755 29.75 755 26.75 679 32.38 822 32.38 822 RA1336 27 685 29.75 755 29.75 755 28.75 730 32.38 822 32.38 822 RA1342 31 787 29.75 755 29.75 755 32.75 831 32.38 822 32.38 822 RA1348 27 685 33.75 857 33.75 857 28.75 730 36.38 924 36.38 924 RA1360 31 787 35.75 908 35.75 908 32.75 831 38.38 974 38.38 974 ALLOW 60"[1524 mm] OF CLEARANCE A 1 R ID I 5 � C �� - (04/SaK'-#1.- G" _ _ .-‘t-111 4 H -- sop:______ ___„,... .-. __...-.-.... ....,._-- ��1� SERVICE PANELS/ ji* . --____ ,..- -..--: =--. --- =_-=-...-..-.- At. 4N, INLET CONNECTIONS/HIGH&LOW VOLTAGE ACCESS ALLOW 24"[610 mm]OF CLEARANCE AIR INLET LOUVERS ALLOW 6"[152 mm]MIN.OF CLEARANCE ALL SIDES 12"[305 mm]RECOMMENDED [ ]Designates Metric Conversions ST-Al 226-02-00 10 RELY ON RUUD.I. Performance Data RA13 Series Performance Data @ AHRI Standard Conditions-Cooling High Sales Volume Tested Combination(HSVTC) Outdoor Total Capacity Net Sensible Net Latent SEER EER Indoor CFM AHRI# Unit Indoor Coil BTU/H[kW] BTU/H[kW] BTU/H[kW] [Us] RA1318AJ1 RCF2417STAM 17600 [5.2] 13100 [3.8] 4500[1.3] 13 11 600[283.2] 7507439 RA1324AJ1 RCF2417STAM 23600 [6.9] 17600 [5.2] 6000[1.8] 13 11 800[377.6] 7507649 RA1330AJ1 RCF3617STAM 28400 [8.3] 21600 [6.3] 6800[2.0] 13 11 1000[471.9] 7507846 RA1336AC1 RCF3617STAM 34600[10.1] 24500 [7.2] 10100[3.0] 13 11 1025[483.7] 7508191 RA1336AJ1 RCF3617STAM 34600[10.1] 24500 [7.2] 10100[3.0] 13 11 1025[483.7] 7508557 RA1342AC1 RCF4821STAM 40500[11.9] 30300 [8.9] 10200[3.0] 13 11 1400[660.7] 7511558 RA1342AJ1 RCF4821STAM 40500[11.9] 30300 [8.9] 10200[3.0] 13 11 1400[660.7] 7511792 RA1348AC1 RCF4821STAM 47500[13.9] 34100[10.0] 13400[3.9] 13 11 1500[707.9] 7508923 RA1348AJ1 RCF4821STAM 47500[13.9] 34100[10.0] 13400[3.9] 13 11 1500[707.9] 7509148 RA1360AC1 RCF6024STAM 56000[16.4] 39600[11.6] 16400[4.8] 13 11 1600[755.1] 7509314 RA1360AJ1 RCF6024STAM 56000[16.4] 39600[11.6] 16400[4.8] 13 11 1600[755.1] 7509436 [ ]Designates Metric Conversions RELY ON RUUD.TM 15