Loading...
Report (2) FIRE ALARM CONTROL PANEL •P-PS / 307 SILENT �'?3� Model 5208 901 KNIGHT Fire Alarm Control Panel by Honeywell with Digital Communicator The Fire Alarm Control Designed to Grow with Your Systems Needs, Without The Growing Pains. The SK-5208 is a microprocessor based control panel with built-in UL listed communicator designed for applications requiring smoke detection, manual pull stations, and sprinkler supervision. It features an easy to read LCD display with programmable English readout and user friendly tactile keys. The basic unit offers 10 zones of initiation and is expandable up to 30 zones for larger applications. The SK-5208 has a complete line of supervised accessories that provide remote annunciation, auxiliary control zone expansion. Ideal for new and retrofit applications, the SK-5208 delivers the performance to handle your installation. Features • Built-in synchronization for • 10 zones, 8 Class B (Style B)and 2 appliances from AMSECO®, Class A(Style D)or Class B (Style Gentex®, Faraday, System Sensor®, B)zones, expandable to 30 zones and Wheelock® • Supervised zone expanders and I/O • Programmable date settings for modules can be mounted remotely Daylight Saving Time from the main control panel • Clock source setting options for 50 I • Event History Buffer(150 events) Hz, 60 Hz,or intemal (uses the with date/time stamp panel's internal clock) • All zones are compatible with 2-or Specifications 4-wire detectors • 8 selectable/programmable output Operating Voltage: 24 VDC patterns for notification appliance Primary AC: 120 Vrms @ 60Hz, 2A circuits Total DC Load: 6 Amp • Built-in Digital Alarm Communicator Current Draw: Transmitter(DACT) Standby: 140 mA • 4 Notification Appliance Circuits Alarm: 460 mA • 4 programmable general purpose Flush Mounting Dimensions: relays Height: 24.75"(62.9 cm) • Programmable smoke verification, Width: 14.5"(36.8 cm) pre-alarm delay, cross zoning and Depth: 3-7/16"(8.73 cm) enhanced verification mode features with 5/8"protruding that can help minimize false alarms Overall Dimensions: SK-5208 • Programmable from the built-in Height: 26-3/8"(67 cm) • Plex-2 Door Option control panel touchpad, remote Width: 17-3/16"(43.66 cm) • SK-SCK Seismic Compliance Kit annunciator, or Windows®SKSS Total Depth: 4"(10.16 cm) downloading software Operating Temp: 32°to 120° F Listings and Approvals • Direct connect port for on-site (0° to 49° C) • UL Listed up/downloading with Windows® Humidity: 10-93% noncondensing • CSFM Listed SKSS downloading software • MEA approval 429-92-E Vol.XIII • Built-in walk test feature Optional Accessories • OSHPD (CA)OSP-0065-10 • Single or dual interlock water • SK-5235 LCD Remote Annunciator releasing capability • SK-5217 10 Zone Expander • Plex door option combines a dead (2 max. per system) front cabinet door with a clear • SK-5280 Status Display Module (8 window, limiting access to the panel max. per system) while providing single button • 5220 Direct Connect Module operation of the reset and silence • 5824 Serial/Parallel Printer Interface functions Module • Programmable AC trouble relay • SKSS Downloading Software FIRE HLARM CONTROL PANEL Model 5208 Fire Alarm Control Panel with Digital Communicator Engineering Specification The system shall contain a fire alarm control panel to supervise and operate heat and smoke detection devices, manual fire alarm devices, alarm notification devices and visual annunciators. The system shall also be capable of monitoring for sprinkler supervisory and water flow conditions. The system must have a built in UL listed fire communicator that can be enabled/disabled as needed on a per job basis. In addition, the system will sound alarms locally for purpose of evacuation. Telephone Line 1 Telephone Line 2 ," ""� Direct Connect For On-Site Programming 2 Class A (Style D) m' s ® 4 �:s ,ot ug or Class B (Style B) � ; - Initiation Circuits ' , Programmable •_ 3 Form C Relays asa, 8Class B (Style B) . . jam ��-* Notification Initiation Circuits 410 • Appliance Circuits 44'4F�FB I 5235 Remote in 44,.------00 } Annunciators _ IFIAII —'�' SBUS Devices i5280, 5217, & 5824 To AC .-, SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA keep our product information up-to-date and accurate.We cannot cover all NI KNIGHTth specific applicationstochangewithout or anticipnotice. Forate all requirements.moreinform All ationspecicontfiactcationsSilent are Knight ©2013 FORM#Honeywell 350318 Rev E by Honeywell 12 Clintonville Road, Northford, CT 06472-1610 Phone:(800)328-0103, International Inc. Fax:(203)484-7118. For Technical support, Please call 800-446-6444. www silpntkninht_cnm a Lw vs SILENT IfZi } me"It? Wtgte Baptist Church Ph#5 . d _; At rnMl _. 650 K.NICII'l Advanced_PreParedar- Securtiy&Fire 1: ` gFactor: 1 2 SK-5208 Calc.;lat,ons Date 7/7/2014 Volt*geDrop Trestkeii,° 10 - Panel-1U JSK-5208 ModeI "5,205,. ;Fite Ala, Control•P,anel "- t ,i4AC Curr y 3.0" Loton:I Fire/Security Closet :" 24 Max8.0 Amps Old# 0iroui#Name" y f Draw wire-.J WG ohms Per t�(4t) Actual VeIs , 160,0j,' Standby_Alarm; E�T 10 3 Ft. " one~Way C t '. 01‘' 81(-5208-:SK-5208 Main Control � ^l` 0.140 0.160 :- - "` NAC KT SK-5208 Prgm'd NAC's 4 0.000 0.160 ALM-R-LY SK-5208 Pgm Alm Rly 0.000 0.000 SK-521-7, SK-5217 Zone Expdr 1 0.060 0.260 j SK-5235;_ SK-5235 LCD Remote 1, 0.035 0.050 S1(- SK-5280 Display Mod 0.000 0.000 -31( 220---SK-5220 Dir Con Mod 0.000 0.000 SK-7181 --SK-7181 Zn Cnvtr 0.000 0.000 5824 Serial/Parallel Cnvtr 0.000 0.000 IDC-1 1st Floor S Side-Ckt 1 0.001 0.095 1t5C-2 : i 1st Floor N Side-Ckt 2 0.001 0.095 `IDC-3 Initiating Device Ckt 3 0.000 0.095 1D.C-4, Initiating Device Ckt 4 0.000 0.095 1CG-S 2nd Floor N Side-Ckt 5 _ 0.000 0.095 IDC-8 2nd Floor S Side-Ckt 6 0.001 0.095 10C-7. 2nd Floor E Side-Ckt 7 0.001 0.095 10C"8 '•Initiating Device Ckt 8 0.000 0.000 " ICC Initiating Device Ckt 9 0.000 0.000 100-`10 Initiating Device Ckt 10 0.000 0.000 IDC-11 Initiating Device Ckt 11 0.000 0.000 IOC-12 Initiating Device Ckt 12 0.000 0.000 IOC-13 Initiating Device Ckt 13 0.000 0.000 100-'14" '.Initiating Device Ckt 14 0.000 0.000 10 -15 ", Initiating Device Ckt 15 0.000 0.000 100-16 Initiating Device Ckt 16 0.000 0.000 100-17 Initiating Device Ckt 17 0.000 0. IOC-18 ``Initiating Device Ckt 18 0.000 0.000 400-19.•`<Initiating Device Ckt 19 0.000 0.000 IDC-20 s:Initiating Device Ckt 20 0.000 0.000 #00-21 Inactive, Add$K-5217 0.000 0.000 100-22 Inactive, Add SK-5217 0.0000.000 ID023 Inactive, Add SK-5217 0.000 0.000 100-24 Inactive, Add SK=5217` 0.000 0.000 100-25 Inactive, Add 8K-5217 0.000 0.000 IDC-28 Inactive, Add SK-52 l7 0.000 0.000 100.27 "Inactive, Add SK-5247 0.000 0.000 100-28 Inactive, Add SK-5217 0.000 0.000 100-29 . Inactive, Add SK-5217 0.000 0.000 100=.30 Inactive, Add SI(5217 0.000 0.000 -.RAO-1," 1st Floor S Side 0.000 1.125 #16 Solid 4.02 200 1,61;. } 18.59 8.87% NAC-2= 1st Floor S Side 0.000 0.875 #16 Solid 4:02 179 1.44 19.14 6.17% NAC-3 1st Floor N Side 0.000 0.750 #16 Solid 4.02 260 2.OG " T, 18.83•" 7.69% NAC-4 let Floor N Side 0.000 0.750 #16 Solid , '402 290 2.33 15.85 8.57% Aux Aux Power Out 0.000 0.000 #12 Solid 1;59 0.00' 20.40 0.00% Total Standby"Current(Ampex 0.238 4.795 Total Alarm Current",(Amps). Standby Time h Flours 80 0.083 Alarm Time In Minutes!80 (5"Mine) Total Standby Ali Requi - 14295 04th Total Atom"A H Rectiered" Total Combined-AH Required: 14.69' Command Shortcuts Multiply By Th-0 "Factor 1.20 , MinBattery At pi-lours'Requlred 1T Configure Circuits Print Page .S11.1,;Vcti -I' ``"" '`I Circuit Configuration Project Name: Westgate Baptist Church Ph#5 Project ID: 0 Prepared By: Advanced Securtiy& Fire Date: 7/7/2014 Ckt. Number: IDC-1 Pani Its: 'SK-5 0 Ckt. Name: >1 st Floor S Side-Ckt 1 Qty err ce Gurent otaw ego. Current©raw Tota 15 System Sensor 2100TS 0.000 100 0 001 ,I 500 #N/A0.000 ' 0,000 0.000 0.000 #N/A 0, 0.000_ ;?0.000 #N/A 0.000 0.000 0 000 oboo 0.000 0.000- Totals 000Totals 0.001 0.095 Ckt. Number: IDC-2 Panel ID: SK-5208 Ckt,Name: 1st Floor N Side-Ckt qty Device ourrerit Draw E; ch Currant I t r `otet $ta dby Alattri Standby :4lartri 10 System Sensor 2W-B 0,000 - 0,100 w 0.001 1.000 Unused 0.000 0.000 0.000 ; 0.000 4 t F Unused 0,0 0.000 0.000 0.000 Unused 0.000 V, , 0.000 0 000 o 000: 0.000 0 000 Totals 0.001 0.095 Ckt.Number. tDC-3 Panel.ID: SK 5208 Ckt. Name:-Initiating Device Ckt 3 afy Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 7 System Sensor 2W-B 0000 " 0.100 0.000 0" 00, Unused 0.000 0 000 0,000 0,000 ,a Unused 0,000 0.000 0.000 0.000 - Unused 0.000 0.000 0,000 0.000 0-000 -0.0 Totals 0.000 0.095 "NI`=III Circuit Configuration Project Name: Westgate Baptist Church Ph#5 Project ID: 0 Prepared By: Advanced Securtiy& Fire Date: 7/7/2014 Ckt.Number IDC-4 Panel 11 :'S1 5248 Mkt N Initiating Devic e'Ckt 4 ; y Qty Device Ctrirerit f)ttomlraot = Gurrent©r r Tata! Stantlbjt : Alam Startr y Alar m-- 3 System Sensor 2W-B 0;000 01011 0.000 0 3. ': Unused :11•1161,1. l 000 Unused 0. :03000-1_r4 0 000 . Unused 0.000" ' � .{ 0 000 s r 0000 0.000 0 Totals 0.000 0.095 Ckt.Number Al C-5 Pmt 1©:,SK-5208 CktName 2n f Floor N Sid - tt 5 Qty Device C ucent d F Current Drawn Total st ttdb Alarm Standby Alar r19 8 System Sensor 2W-B 0.000 U 0.1 E 040 q 800 Unused 0.000 `f 0.000 0.000 :`0.000 Unused 0 0 0.000 0000; Unused 0000 0;000 0001 ;0-000 0-000 Totals 0.000 0.095 Ckt.Number:10C-6 Parcel I):. Sl-5208: Ckt latae 2nd Floor S Side-Ckt6 tfy Device Current tr`awr Each Current Draw Total Standby Alarm Standby ; Alarms 10 System Sensor 2W-B t}r000 0.1- 0 y 0.001 1000 Unused 0.000 11.000 Oft 0 0€i Unused 0.000 000 0.000 0 t 00 Unused 0.000 0.000 0.00° 0.060 0 Totals 0.001 0.095 FIRE SYSTEM ACCESSORY Model 5495 SILENT Distributed Power Module KNIGHT In an emergency, by Honeywell you need maximum power The 5495 Distributed Power Module by Silent Knight is the most powerful and cost-effective power supply available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensor®,Gentex®,AMSECO®, Wheelock and Faraday—what you need to drive power- hungry components like ADA notification appliances. The 5495's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies.And,ADA retrofits are easier and less expensive with the 5495 because it integrates into current systems without the costly investment in new components. For the most sophisticated and cost-effective notification power supply available, you need the 5495. Call Silent Knight today for more information at 1-800-328-0103. Model 5495 to non-essential high-current Distributed Power Module accessories like magnetic door holders The 5495 is a 6 amp notification power • Built-in synchronization for 1 expander that provides its own AC appliances from System power connection, battery charging Sensor®,Gentex®,AMSECO®, circuit, and backup battery for use with Wheelock and Faraday fire and security controls such as the Silent Knight Model 5208 Fire Control • Stand alone operation /Communicator. The 5495 is the cost- • Lightweight design adds to ease of effective solution for powering installation and reduces shipping in 9 notification appliances required by the costs Americans with Disabilities Act(ADA). • Operates with most polarized, UL The 5495 has built-in ANSI cadence Listed notification devices pattern, which can upgrade older control panels that lack cadence • ANSI Cadence pattern output capability. capability built-in Features Connection to Local Fire Control • UL Listed for 6 amps of notification The 5495 may be connected to a local fire control which utilizes Class A or Model 5495 power Class B type notification circuits Distributed Power Module • Power supply's advanced switch operating between 9 and 32 VDC.The mode design reduces damaging control panel's notification circuit is Approvals heat and manages power up to 50% connected to one of the inputs on the • UL Listed more efficiently than other systems 5495.The control panel's notification • MEA 429-92-E Vol XII • Dip switches allow for easy circuit end-of-line resistor is also • CSFM 7300-0559:123 reconfiguration connected across two terminals on the • • 24 VDC filtered output voltage 5495, which provides supervision NFPA 72 between the 5495 and the fire control • OSHPD(CA)OSP-0065-10 • Four power-limited notification (see outputs; 2 Class A or 4 Class B, or 1 panel. Polarized audible and/or visual accessories) Class A and 2 Class B notification devices are then connected • Additional continuous auxiliary to the 5495 signal circuits using the output 4.71d)end-of-line resistors provided. Since the 5495 draws very little power • 3 amps per output circuit from the control, it is possible to • 2 inputs; 2 Class B or 2 Class A connect one 5495 to each notification • Ground fault detector/indicator circuit on the control panel and still • Independent trouble relay provide full supervision of the • AC loss delay option shuts off power notification circuits all the way back to the.rnntrnl nano! FIRE SYSTEM ACCESSORY Model 5495 Distributed Power Module Model 5495 Block Diagram Signal Circuit Output Signal 1 Signal 1 Input Distributed Signal 2 Signal Circuit Output Signal 2 Power Input Module 5495 Signal 3 (Optional) Signal 4 120 VAC Aux. Power Trouble Output Local Fire Control (Alternative to notification circuit trouble.) Supervision Current: Input The 5495 supervises a variety of Standby 75 mA voltage range: 9-32 VDC functions including: Alarm 205 mA Battery charging • Low AC power Auxiliary capacity: 35.0 AH • Low battery condition power circuit: 1 Ambient temp.: 32° to 120° F • Earth ground fault Notification (0° to 49° C) • Auxiliary output power limit circuits: 4 Mechanical condition • EOL supervision trouble or Output Dimensions: 12.25" W x 16" H x configuration: 2 Class A(Style Z) 3" D (30.88 cm W power limited condition at an 4 Class B (Style Y) x 40.64 cm H x output (1 Class A& 7.62 D cm) When a trouble condition occurs, 2 Class B) the 5495 creates a trouble Indicator Lights condition on the host control signal Amps per AC power on : Green circuits to which it is connected. the output circuit: 3.0 (6.0 amps total) Battery trouble: Yellow 5495 still maintains the ability to be Notification Ground fault: Yellow activated by the host control. In circuit output: 20.4 to 27.3 VDC addition, the 5495 provides a Form @ 3.0 amps each, Aux trouble: Yellow C trouble relay output as an 4.7 kS2 EOL Output troubles (1-4): Yellow alternative to using the notification resistor required Ordering Information circuit trouble. on each Class B 5495 Distributed Power Module circuit Electrical Specification Accessories: No. of inputs 2 AC input: 120 VAC at 2 amps SK-SCK Seismic Compliance Kit Input Output: 24 VDC at 6 amps configuration: 2 Class B or 2 Class A • SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA fs KNIGHT oup-to-do specikeepfiourc applicationsprductinformation or anticipate all requirements.ateand Allaccurate.specifications Wecannotcare all FORM#350395 Rev F subject to change without notice. For more information,contact Silent Knight ©2013 Honeywell International Inc. by Honeywell 12 Clintonville Road, Northford,CT 06472-7161 Phone:(800)328-0103, Fax:(203)484-7118.For Technical Support, please call 800-446-6444. -tabat Values:" SII,EN'I s traject Islamic Westgate Baptist-Phase#4 Stant y Hour 24 - 1110 KNIGI I'1' -Project 113:1 Alarm os: 5 Prepared By: Advanced Security&Fire Deratkig Factor 12 5495 Power E:x:pander Calculat ons pate:17/7/2014 Vdltettopttit�'; Panel t#):;5495(1) Model: Silent Knight 5495 Power Expander. " Max Circuit Current, 3 Amps . Location: 2nd Floor-West Hall Volts: :24 VDC Max P�Current: S Arra Cid.* Circuit Name" Currrt:t:3raw Wire AWG Ohms Per Length(ft) . Actual Volts @ Standby Alarm. :. &Type 1000 Ft." One-Way . Ohms EOL �SbDrap.; 1` 5495(1)Circuit 1 0.000 0.422 #16 Solid 4.02177 1.42 19.80 2.95% 2 5495(1)Circuit 2 _ 0.000 0.252 #16 Solid 4.02 242 1.95 19.91 2.40% 3 5495(1)Circuit 3 0.000 _ 0.000 #12 Solid 1.59 0.00 20.40:. ' 0.00% 4 5495(1)Circuit 4 0.000 0.000 #12 Solid 1.59 0,00- 20.40 0.00% Aux 5495(1)Aux Power Out 0.000 0.000 #12 Solid 1.59; 000 20.40 0.00% • 5495 "5495 Power Expander " " 0.075 0.205 0.674 (Amps)Total Output Power,Required Total Standby Current(Amps}""0.075. . 9,879 TSI"Alarm Current(Amps) , Standby Time in Hours 24 0.083 Alarm Time In Minutes i 60 (5 Mins) Total Standby All Required 1 8tXt s" 0.073 Total Alarm AH Required Total Combined AH Required 1.87 Wire resistances are based upon an ambient temperature of 72 degrees F. Because of multiply y By ie'L Factor 1.20 the minimal difference between solid and stranded wire no differential was made. - Minimum.Battery Amp fours Required 2.25 " Panel 10: 5495(2) Model: Silent Knight 5495Power_E_xpander Max Circuit Current: 3 Amps Location: Volts: " 4 V0C Max Panel Current: 6 Amps`. Ckt# Circuit Name. Current Draw Wire AWG Ohms Per Lengh(ft) Actual Volts @ % " Standby Alarm ,&Type 1000 Ft. ; One-Way Ohms Ecol:.' `°p 1 5495(2)Circuit 1 0.000 0.000 #12 Solid 1.59 0.00 20.40' 0.00% 2 ,5495(2)Circuit 2 0.000 0.000 #12 Solid 11.59. 400 20.40 0.00% 3 5495(2)Circuit 3 0.000 0.000 #12 Solid 1.59 " 0.00 20.40 0.00% 4 " 5495(2)Circuit 4 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% Aux 5495(2)Aux Power Out 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% 5495 5495 Power Expander s 0.075 0.205 0.000 (Amps)Total Output" Power"Required Total Standby Current(Amps) 0.075 0205 Total Alarm Current(Amps) Standby Time In Hours 24 0.083" Alarm Time In Minutes(60 (5 Mins) Total Standby AK Required 1.$00., 0.017 ;Total Alarm AK Required Total Combined AH Required" 1.82 Wire resistances are based upon an ambient temperature of 72 degrees F. Because of Multiply$y The"Derating F or 1,20- the minimal difference between solid and stranded wire no differential was made. Minimum Battery Ampliours Required 2.18 RII1'.A4110 '[- ` " Circuit Configuration •roJ- norma ion Project Name: Westgate Baptist-Phase#4 Project ID: 0 Prepared By: Advanced Security&Fire Date: 7/7/2014 Ckt.Number: 1 . Panel ID 5495(1 Ckt.Name; 5495(1)Circuit 1 Max Circuit Current." , 3Amps.. Device Current:Draw Each ,-Comes t rtivfTotat =;St i� , Alarm Standby :fir-m. 2 System Sensor P2R 15cd 0 } 3 System Sensor P2R 15/75cd ;O 000 = 0.077 0.000 : 1 System Sensor P2R 95cd ,0000 2 System Sensor P2R 115cd 0 00 tt-01 0 X00 0041 0.000 0;000m Totals 0.000 0.422 tct.Nur er 2 . Panel iD 95 1} Ckt Name 5495(1)Circuit 2 Max Circuit Guru 3 AiTIPS Devices >rerit Dramf Etach CurrentsDraw otat. : Standby. Alarm Standby. 2 System Sensor P2R 15/75cd 0.000 0.077 0 000 0.1:54 2 System Sensor P2R 95cd 0000';"`` 0.0#1# 0000 0036 3 System Sensor P2R 115cd ;0.000 0.02 0-000`=: 0.062: Unused 0000"° '� µ;0.'t 0 `°-0.000 3.000 0.000- Totals✓ 0.000 0.252 � t Numt er 3.` Panel iii.54 {1j Ckt,Naive 049501)Circuit 3 . Max Cir itCurr -3 Aram Qty Device urrent.7rat�t'Eti Current: raw ToteG'. Standby Alarm Standby:;" Alarm Unused 0 000" . 0-000 0 000": 0,000: Unused 0000 11;000 0000 0,000"; Unused `0.000 0.0 OOH Unused 0.000. "~ 0.000 ,0„00-0, 0.000,; Totals 0.000 , 0.000 lct:"Number: 4 Panel ID:5495(1? Ckt Name:5495(1)Circuit 4 = Max.Circuit Current'" 3 Amps Qty " Device Current Draw Ea t ; Current Draw"Total" ',Standby AtarrnStandby- `Alarm" Unused :0000 0.00 0000: Unused 0 100., 00 0.000 Unused 0,000 0.000 0000"° 0,000 v,i Unused 0.000', 0.000' -P1460,- 0.000. 0.000 Totals __ 0.000 0.000 \ __*V SENSOR' Indoor Selectable- Output Horns, Strobes, and40,07. x, Horn Strobes for dY Wall Applications SpectrAlerto Advance audible visible notification products SPECTRAlert are rich with features guaranteed to cut installation times ihriarly c and maximize profits. Features The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns, strobes,and horn strobes in the industry. • Plug-in design with minimal intrusion into the back box With white and red plastic housings,wall and ceiling mounting • Tamper-resistant construction options, and plain and FIRE-printed devices,SpectrAlert Advance • Automatic selection of 12-or 24-volt operation at can meet virtually any application requirement. 15 and 15/75 candela Like the entire SpectrAlert Advance product line,wall-mount horns, • Field-selectable candela settings on wall units: 15, 15/75, strobes,and horn strobes include a variety of features that increase 30,75,95, 110, 115. 135, 150, 177,and 185 their application versatility while simplifying installation.All devices • Horn rated at 88+dBA at 16 volts feature plug-in designs with minimal intrusion into the back box, • Rotary switch for horn tone and three volume selections making installations fast and foolproof while virtually eliminating • Universal mounting plate for wall units costly and time-consuming ground faults. • Mounting plate shorting spring checks wiring continuity before To further simplify installation and protect devices from construction device installation damage,SpectrAlert Advance utilizes a universal mounting plate • Electrically Compatible with legacy SpectrAlert devices with an onboard shorting spring,so installers can test wiring continuity before the device is installed. • Compatible with MDL3 sync module • Listed for ceiling or wall mounting Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with three volume selections. Agency Listings SIGNALING t MEA approved 7125-1653.186(Indwr strobcn) LISTEDa►rAweo 7125-1653188(horn strobes, 54011(chimes,horn strobe3,norms} 3023572 MEA452-05-E chlmestrobes) 55512(strobes) 7135-1653;189 thorns,chimes; SpectrAlert Advance Specifications Architect/Engineer Specifications General SpectrAlert Advance horns,strobes,and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch octagon back box,or double-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•Circuit-Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95, 110, 115, 135, 150, 177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. t'o c.t 4 Co ,4t v e The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.On four-wire products.the strobe shall be powered independently of the sounder.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR" Operating Voltage Rangel 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wail-mount LJimensions(including tens) 5.6-L x 4.7"W x 2.5-D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.3"D(142 mm L x 119 mm W x 33 mm D) Wall-Mount Trim Ring Dimensions(sold as a 5 pack)(TR-HS) 5.7"L x 4.8""W x 0.35"D(145 mm L x 122 mm W x 9 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S, PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8--175 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 i;arpcteia 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-temporal High 57 56 69 75 95 NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 kuiVrrilti7S11111':1 9P •1:t y1irRrlii. 3 ..E.,- .e.., ...11r7fit-."541=1. .;,, ,.. 8-175 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Tones and Sound Output Data Horn and Horn Strobe Output(dBA) 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 75 75 80 80 86 86 96 96 3 Temporal Low 71 71 76 76 83 80 94 89 4 Non Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 73 74 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 81- Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 74 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobes, • SpectrAlert Advance Dimensions 14 4.7" • 2.5'=--.. W NGT Pm �. C '� 5.6" i tz:t711i==r7 • III ` � Wall-mount horn strobes SpectrAlert Advance Ordering Information Model Description Model Description Wall Horn Strobes Wall Strobes(cont.) P2R 2-Wire Horn Strobe,Standard cd,Red SRH Strobe,High cd,Red P2R-P 2-Wire Horn Strobe,Standard cd,Red,Plain SRH-P Strobe,High cd,Red,Plain P2R-SP 2-Wire Horn Strobe,Standard cd,Red,"FUEGO" SRH-SP Strobe,High cd,Red, "FUEGO" P2RH 2-Wire Horn Strobe,High cd,Red SW Strobe,Standard cd,White P2RH-P 2-Wire Horn Strobe, High cd,Red,Plain SW-P Strobe,Standard cd,White,Plain P2W 2-Wire Horn Strobe,Standard cd,White SWH Strobe,High cd,White P2W-P 2-Wire Horn Strobe,Standard cd,White, Plain SWH-P Strobe, High cd,White,Plain P2WH 2-Wire Horn Strobe,High cd,White Horns P2WH-P 2-Wire Horn Strobe,High cd,White,Plain HR Horn,Red P4R 4-Wire Horn Strobe,Standard cd,Red HW Horn,White P4R-P 4-Wire Horn Strobe,Standard cd,Red,Plain Accessories P4RH 4-Wire Horn Strobe,High cd,Red TR-HS Trim Ring,Wall,Red P4W 4-Wire Horn Strobe,Standard cd,White SBBR Indoor Surface Mount Back Box,Red Wall Strobes SBBW Indoor Surface Mount Back Box,White SR Strobe,Standard cd,Red SR-P Strobe,Standard cd,Red, Plain SR-SP Strobe,Standard cd, Red, "FUEGO" Notes: All-P models have a plain housing(no"FIRE"marking on cover) All-SP models have"FUEGO"marking on cover "Standard cd"refers to strobes that include 15, 15/75,30,75,95,110,and 115 candela settings. "High cd"refers to strobes that include 135,150,177,and 185 candela settings. 1 1 IV! 3825 Ohio Avenue•St.Charles, IL 60174 ©2814:System S rsc SEATS�.+r �w� _ Phone:800-SENSOR2•Fax 630-377-6495 Produc-GP fflce tisubject to hang without nctia.+rt sys rnsensh et R for current productintorrnahch cluding the latest ion of this data sheet. �i�mmm///i.. R./ www.systemsensor.com AJOSso,_us•1/14 r (j)Smoke Detector Specifications Architectural/Engineering Specifications Smoke detector shall be a System Sensor P Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The detector shall be a photoelectric type(Model 2W-B,4W-B)or a combination photoelectric/thermal(Model 2WT-B,4WT-B)with thermal sensor rated at 135°F (57.2°C).The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal,single-gang,and 4-inch square back boxes with a plaster ring,or direct mount to the ceiling using drywall anchors.Wiring connections shall be made by means of SEMS screws.The detector shall allow pre-wiring of the base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box.The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual- color LED indication that blinks to indicate power up,normal standby,out of sensitivity,alarm,and freeze trouble(Model 2WT-B,4WT-B)conditions.When used in conjunction with the 2W-MOD2 module,2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Electrical Specifications Operating Voltage Nominal: 12/24V non-polarized Minimum: 8.5 V Maximum:35 V Maximum Ripple Voltage 30%peak to peak of applied voltage Standby Current 2-wire:50 pA maximum average;4-wire:50 pA maximum average Maximum Alarm Current 2-wire:130 mA limited by control panel;4-wire:20 mA @12 V,23 mA @ 24 V Peak Standby Current 2-wire:100 pA;4-wire:n/a Alarm Contact Ratings 2-wire:n/a;4-wire:0.5 A @ 30 V AC/DC Ph sical S•ecifications Dimensions(including base) 5.3 inches(127 mm)diameter;2.0 inches(51 mm)height Weight 6.3 oz(178 g) Operating Temperature Range 2W-B and 4W-B:32°F to 120°F(0°C to 49°C);2WT-B and 4WT-B:32°F to 100°F(0°C to 37.8°C) Operating Humidity Range 0 to 95%RH non-condensing Thermal Sensor 135°F(57.2°C)fixed Freeze Trouble 2WT-B and 4WT-B only:41°F(5°C) Sensitivity 2.5%/ft nominal Input Terminals 14 to 22 AWG Mounting 31-inch octagonal back box 4-inch octagonal back box Single-gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED Modes Power-Up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal(standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information Model Thermal Wiring Alarm Current 2W-B No 2-wire 130 mA max.limited by control panel 2WT-B Yes 2-wire 130 mA max.limited by control panel 4W-B No 4-wire 20 mA @ 12 V,23 mA @ 24 V 4WT-B Yes 4-wire 20 mA @ 12 V,23 mA @ 24 V Accessories 2W-MOD2 2-wire loop test/maintenance module RT Removal/replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket,6.6 inch(16.76 cm)diameter *Th, SYSTEM 3825 Ohio Avenue•St.Charles,IL 60174 cod tts 02009 System Sensor. pecifications subjecttochange without notice Visit systemsensoccom for SENSOR- Phone:800-SENSOR2•Fax:630-377-6495 currant product information,induding the latest version of this data sheet. A05-0318-007.6/09-#2169