Loading...
Plans BUP2015 - 00347 3 2 LEGEND :=::i:I:== EXISTING CONSTRUCTION TO BE DEMOLISHEDErum"' WARD JONES 4 tx'S EXIT c� EXISTING WALL TO REMAIN rA OFFICE ,.. oma® NEW WALL TO UNDERSIDE OF GRID, SEE 3/A8.1 xts 105 _ ��� P-2 / P-2 OFFICE 5 o EXISTING 1 HOUR RATED WALL TO REMAIN Architecture-Interiors P-2 1 106 TENANT IMPROVEMENT 1�{t 6 SFE 7 REC1PP1 ION EXISTING DEMISING WALL TO REMAIN Planning-Engineering 3 t IP XIS ti' EXISTING BASE FEED i� STORARGE 4 y HALL �I NEW QUADRUPLEX OUTLET 1 LINCOLN 104 103 °� NEW DEDICATED SIMPLEX OUTLET TO BE MARKED WITH "D" AND ORANGE ECEIVEI g Portland,OR V HALL 106A O P I,,,_r 503.224.9560 10300 SW GREENBURG ROAD O � 102 v Tt�'`= EXISTING OUTLET AND VOICE/DATA ROUGH IN LOCATION $ 2015 f N I 1 Vancouver,WA qpA NEW OUTLET AND VOICE/DATA ROUGH IN LOCATION CITY OF HGARI) 360.695.7879 p� NEW DOUBLE GANGED VOICE/DATA ROUGH IN LOCATION TIGARD OREGON BUILDING DIVISION SeattleWA' 206.749.9993 PARTIAL FIRST FLOOR PLAN -Q. EXISTING COVERPLATE LOCATION TO RECEIVE NEW DUPLEX OUTLET www.mcknze.com EXISTING COVERPLATE INDEX OF DRAWINGS M AC K E N Z I E D g � EXISTING LIGHT SWITCH DESION DRIVEN I CLIENT iOODSED A2.1 PARTIAL FIRST FLOOR PLAN, REFLECTED CEILING PLAN, KEY PLAN, SITE PLAN Client NEW LIGHT SWITCH WITH OCCUPANCY SENSOR AND NOTES 100�� NEW 3—WAY LIGHT SWITCH A8.1 DETAILS, ELEVATIONS AND SCHEDULES 2�E W C�ONHUS RTION AVE NEW LIGHT SWITCH FOR CAN LIGHT SCOPE OF WORK TUALATIN,OREGON FS EXISTING FIRE STROBE TO BE REMOVED/RELOCATED THE SCOPE OF WORK FOR THE PROJECT INCLUDES INTERIOR TENANT IMPROVEMENTS Y' c PROPOSED NEW FIRE STROBE LOCATION — DESIGN BUILDER TO PROVIDE DEFERRED SUBMITTAL FOR AN APPROXIMATELY 1,171 SQUARE FOOT TENANT ON THE FIRST OF FIVE FLOORS. 10 re WORK TO INCLUDE NEW WALLS AND DOOR. Fs EXISTING FIRE EXTINGUISHER TO BE RELOCATED J 8 C'1 LU )C( FE e RELOCATED FIRE EXTINGUISHER PERMIT SET DEVELOPED FROM TENANT PROVIDED DOCUMENTS, FOR BUILDING PERMIT. CONTRACTOR TO SEE ATTACHED REFERENCE DRAWINGS FOR ADDITIONAL PROJECT FA Project EXISTING FIRE ALARM INFORMATION, PROCUREMENT AND SPECIFICATION REQUIREMENTS. EDWARD JONES .d,z (21 EXISTING THERMOSTAT SUITE 140 _ YY \ TENANT APPROVAL: TENANT ~� EXISTING THERMOSTAT TO BE RELOCATED r: IMPROVEMENT OT RELOCATED THERMOSTAT 2 REFLECTED CEILING PLAN O1 . KEY NOTE FOR REFERENCE DESIGN/CODE DATA 1 LINCOLN 10300 SW GREENBURG RD A2.1 1/8"=1'-0" tOOA DOOR NUMBER SYMBOL11GARD,OREGON GOVERNING CODE:. 2014 OSSC xIs EXISTING DOOR TO REMAIN OCCUPANCY: BCONSTRUCTION TYPE: TYPE I—B 1 n EXIT REQUIRED EXIT TENANT AREA (APPROX): APPROX. 1,172 S.F. `fit C OCCUPANCY LOAD: 12 EXISTING CEILING GRID ~ AUL G 1 REQUIRED EXIT, 1 EXIT PROVIDED GENERAL NOTES EXISTING SUPPLY/RETURN VENT TO REMAIN EXIT IS EXISTING AND HAS APPROPRIATE EXIT SIGNAGE . ' .� , I BUILDING HAS NFPA SMOKE DETECTION WITH ON SITE EMERGENCY PORT 1 , R G0 A. ALL EXISTING CONDITIONS TO REMAIN, UNLESS NOTED OTHERWISE. a; EXISTING EXIT SIGN TO BE REMOVED RELOCATED B. DIMENSIONS REFLECT FACE OF FINISH TO FACE OF FINISH, UNLESS NOTED OTHERWISE. REMOVED/RELOCATED FOR FIRE, LIFE/SAFETY BACKUP POWER C. WALL THICKNESSES ARE NOMINAL, UNLESS NOTED OTHERWISE. 0 PROPOSED NEW EXIT SIGN LOCATION — DESIGN BUILDER TO PROVIDE DEFERRED SUBMITTAL p/] Qj'i D. SUSPENDED ACOUSTICAL TILE CEILINGS AT 8'-5"t (EXISTING) AFF, UNLESS NOTED OTHERWISE. DEFERRED SUBMITTAL E. FOR SEISMIC BRACING OF SUSPENDED CEILING AND INTERSTITIAL EQUIPMENT SEE DETAILS 1/A8.1. ® NEW OR RELOCATED 2x4' FLUORESCENT LIGHT FIXTURE F. CENTER ALL DOWN LIGHTS, SMOKE DETECTORS AND ALL OTHER CEILING PENETRATIONS IN CENTER OF 2x2 TILE, UNLESS NOTED OTHERWISE. - EXISTING 2'x4' FLUORESCENT LIGHT FIXTURE TO REMAIN 2014 OSSC SECTION 107.3.4.2 (by separate permit) © MACKENZIE 2015 I ti G. ELECTRICAL, DATA AND SWITCHING LOCATIONS ARE SHOWN TO CONVEY GENERAL INTENT ONLY. --- FIRE ALARM ALL RIGHTS RESERVED COORDINATE ELECTRICAL/DATA/SWITCHING REQUIREMENTS WITH TENANT AND PROVIDE DRAWINGS BY MECHANICAL THESE DRAWINGS ARE THE PROPERTY DEFERRED SUBMITTAL. DEMOLISHED 2'X4' FLUORESCENT LIGHT FIXTURE TO BE RELOCATED USOF ED OR REPRODUCED IN ANY MAONNER, '� ELECTRICAL H. FURNITURE IS SHOWN FOR SCHEMATIC PURPOSES ONLY. TENANT OR TENANT'S VENDOR TO CONFIRM i EXISTING 2'x4' 24 HR EGRESS FLUORESCENT LIGHT FIXTURE TO REMAIN EXIT ILLUMINATION WITHOUT PRIOR WRITTEN PERMISSION BUILT CONDITIONS FOR SPATIAL REQUIREMENTS AND FINAL LAYOUTS. I. HVAC CONTRACTOR TO PROVIDE FULL SHEET OF THE FLOOR AFFECTED UPON COMPLETION. REVISIONS: CONTRACTOR IS RESPONSIBLE TO PROGRAM THE OVERRIDE HVAC BUTTON. EXISTING 2'x2' FLUORESCENT LIGHT FIXTURE TO REMAIN NOTE: DESIGN BUILDERS FOR M.E.P. AND FP. ARE FULLY RESPONSIBLE FOR THE DESIGN z J. ALL INTERIOR WALLS TO GO TO UNDERSIDE OF GRID UNLESS NOTED OTHERWISE. OF THESE SYSTEMS/COMPONENTS. THESE SYSTEMS/COMPONENTS SHOWN ON DOCUMENTS oQ REVISIONS REVISION DELTA K. ALL INTERIOR DOORS TO BE SOLID CORE FLUSH WOOD DOORS TO MATCH SUITE STANDARD UNLESS EXISTING 2'x2' 24 HR EGRESS FLUORESCENT LIGHT FIXTURE TO REMAIN ARE SCHEMATIC ONLY. THEY ARE NOT INTENDED TO REPRESENT FINAL/CODE COMPLIANT �o SWEET CLOSING DATE NOTED OTHERWISE. DESIGN. PROVIDE DESIGN DOCUMENT SUBMITTAL TO ARCHITECT OF RECORD FOR REVIEW L. OUTLETS INDICATED ARE EXISTING UNLESS NOTED OTHERWISE. SITE VERIFICATION HAS BEEN DEMOLISHED 2'X2' FLUORESCENT LIGHT FIXTURE TO BE RELOCATED PRIOR TO SUBMITTAL PERFORMED (ON 9/10/2014, WHILE OCCUPIED, AND ROOM 105 WAS LOCKED AND INACCESSIBLE AND NOT VERIFIED) AND PLAN, ELECTRICAL AND CEILING INFORMATION HAS BEEN UPDATED (OBSERVATION ® NEW OR RELOCATED 2'X2' FLUORESCENT LIGHT FIXTURE 1 IS LIMITED TO VISIBLE/ACCESSIBLE AREAS). CONTRACTOR TO FIELD VERIFY AND CONFIRM ADDITIONAL VALUATION REQUIREMENTS WITH TENANT. G EXISTING RECESSED CAN LIGHT TO REMAIN M. NO VOC PAINT SYSTEMS TO BE UTILIZED, TO INCLUDE PRIMERS AS WELL AS FINISH PRODUCTS. O NEW RECESSED SPOTLIGHT CAN TI N. LIGHTING LAYOUT IS SHOWN FOR PRELIMINARY DESIGN INTENT ONLY. FINAL LIGHTING LAYOUT TO BE VALUATION OF WORK = $16,895 PROVIDED BY THE ELECTRICAL CONTRACTOR AND IS DEPENDANT ON OREGON ENERGY CODE NEW BATT INSULATION CENTERED ON WALL ALLOWANCES AND EXISTING BUILDING INFRASTRUCTURE IN CEILING. 0. ALL DIMENSIONS SHOWN AS PLUS/MINUS (t) ARE FOR GENERAL LAYOUT AND REFERENCE ONLY. ""s" TI'OFTIGARD VERIFY AND CONFIRM ALL DIMENSIONS AND CONDITIONS PRIOR TO START OF WORK. NOTIFY FOR CODE CgMPLIANCB ARCHITECT/ENGINEER OF ANY DISCREPANCIES PRIOR TO START OF WORK. " SHEET TITLE: P. REPLACE DAMAGED AND SOILED CEILING TILES WHERE AFFECTED BY CONSTRUCTION TO MATCH �L.u, l DApprO° [ PARTIAL FIRST EXISTING. [1� Q. ADD SOUND INSULATION IN ALL NEW WALLS. -006q7 FLOOR PLAN, KEYNOTES a . , Aaategs: o CEILING PELDAN, AREA OF Suits# 1. ALIGN NEW WALL WITH EXISTING WALL. WORK �o r n J BSC- Date: ( KEY PLAN, SITE 2. CENTER NEW WALL WITH EXISTING MULLION, SEE DETAIL 4/A8.1. MODIFY EXISTING WINDOW LONGEST COMMON ( r / PLAN AND NOTES COVERINGS AS REQUIRED. `�( 3. CONFIRM EXISTING SEALANT WHERE EXISTING WALL MEETS COLUMN AND/OR MULLION. PROVIDE NEW PATH OF EGRESS SEALANT AS REQUIRED TO MITIGATE SOUND TRANSFER. — 78—1 p — OFFICE COPY 4. CONFIRM IF INSULATION OCCURS AT EXISTING WALL. IF NOT, PROVIDE NEW BUILDING STANDARD W DRAWN BY: LER INSULATION WITHIN EXISTING WALL IF REQUIRED. ®®® 5. PROVIDE ELECTRICAL TO ACCOMMODATE NEW DOOR BELL. DOOR BELL CHIME TO BE LOCATED WITHINAREA OF % CHECKED BY: SBH, PDK HALL 102. CONFIRM FINAL LOCATION OF DOOR BELL AND DOOR BELL CHIME WITH TENANT. DOOR WORKSHEET: BELL TO BE HEATH ZENITH WIRELESS PLUG—IN DOOR CHIME WITH WHITE COVER AND HORIZONTAL Q LINES — HOME DEPOT MODEL #DL-6168 OR COMPARABLE ALTERNATIVE. O 6. CONVERT EXISTING SWITCH TO BE 3—WAY. SW 01k S11 1 7. PROVIDE BLOCKING AS REQUIRED TO ACCOMMODATE TENANT PROVIDED SIGNAGE. CENTER SIGNAGE A2.1 ON WALL INDICATED. BOTTOM OF SIGNAGE TO BE 6'-0" AFF. CONFIRM FINAL REQUIREMENTS PRIOR (OCO(A .,.x, � TO INSTALLATION WITH TENANT. KEY PLAN 4SITE PLAN 8. PROVIDE NEW 2'x2' PHONE BOARD. REFER TO 6/A8.1. CONFIRM FINAL REQUIREMENTS WITH TENANT.9. PROVIDE BATT INSULATION ABOVE CEILING TILES, 4'-0" CENTERED ON WALL. .1 FIRST FLOOR NTS A2.1 1 LINCOLN NTS JOB N0. 10. PROVIDE (1) RECESSED DIRECTIONAL SPOTLIGHT CAN W/ WHITE ADJUSTABLE EYEBALL TRIM KIT 2150955,11 UTILIZING AN ENERGY SAVING BULB. CONFIRM FINAL LOCATION AND SPECIFICATIONS WITH TENANT. TRUE PLAN TRUE 11. CONFIRM EXISTING DEMISING WALL TERMINATES AT STRUCTURE. IF NOT, EXTEND TO STRUCTURE. NORTH NORTH NORTH PERMIT SET: 12/4/15 215095511\4_DRAWINGS\ARCHITECTURAL\I1J2.1.OWG LER 12/04/15 13:50 1:96.00 FLOOR OR ROOF STRUCTURE 1 LINCOLN STUD SIZE: 21�" POP RIVET RUNNER TO 7/8" WALL ANGLE AT 2 SERC 2 g" MAX. ADJACENT WALLS, FASTEN CLOSURE ANGLE WITH #6 CLIP SCREWS DIRECTLY TO WALL FRAMING OR PROVIDE STRUT LIMITING WALL HEIGHT TABLE DOOR SCHEDULE STABILIZER BAR BETWEEN ALL MEMBERS AT PERIMETER ADDITIONAL #12 WIRE SUPPORT AT ALL MEMBERS ° A INTERIOR NON STRUCTURAL NON-COMPOSITE WALLS L/240 ® 5psf 4 WITHIN 8" OF PERIMETER DOOR DOOR DOOR FRAME HDWR p m DOOR DETAILS RATING COMMENTS LATERAL BRACING WITH APPROVED VERTICAL \ DESIGNATION SPACING MAX.WALL HEIGHT OPENING SIZE THK TYPE MAT'L FINISH MAT'L FINISH GROUP COMPRESSION STRUT AT 12'-0" OC EA WAY e 250S125-18 24" 8'-4" EXIST 3'-0"x8'-3"t EXISTING DOOR///F,—,,COUNTERSLOPE HANGERS IF MORE THAN 1:6 OUT OF PLUMB104A 3'-0"x8'-3"t EXISTING DOOR H-2 -- 1 Architecture`Interiors e 250SI25-18 16" 9'-7" 106A 3'-D"x8'-3"f 1%" FL SC S HMK FF 5/A8.1 H-1 -- -- Planning y Engineering "ATTACHED m� 250S125-27 24" 9'-10" HARDWARE GROUPS: ABBREVIATIONS: WALL" 0 ° H-1: PASSAGE LATCHSET F75 GRADE 1, OO 2505125-18 16" 11'-3" EXIST EXISTING � FF FACTORY FINISH 362S125-18 24" 13'-5" BUTTS, SEAL, STOPS CEILING®GE AT WALL FL FLUSH H-2: SERVER STORAGE HMK HOLLOW METAL KNOCKDOWN A 362S125-18 16" 14'-4" Portland,OR NOTE: FOR UNATTACHED WALLS PROVIDE A 1/2" LOCKSET F86 A 560 TO 3/4" GAP BETWEEN EDGE OF ANGLE AND CLIP 362S162-33 16" 16'-5" BUTTS,SEAL, ST1OPS, SC SOLID CORE WOOD ADE 1, S STAIN Vancouver,WA X., -- DO NOT SCREW SERC 2 CLIP TO TRACK 3625162-43 16" 18'-0" CLOSER 360.695.7879 TABLE MAX. LENGTH 6005162-33 16" 24'-6" Seattle,WA �' CROSS RUNNERS FIT BETWEEN MAIN RUNNERS — DOOR SCHEDULE COMMENTS: DOOR SCHEDULE NOTES: 206.749.9993 1/2" DIA CONDUIT (EMT) 5'-10" A. ALL DOORS CLOSURES TO BE CHECKED, ADJUSTED, MAIN RUNNERS AT 4'-0" OC INTERIOR NON STRUCTURAL NON-COMPOSITE WALLS 1. EXISTING DOOR TO RECEIVE / www.mcknze.com 3/4" DIA CONDUIT EMT 7'-8" WITH CERAMIC TILE FACING L/360 ® 5psf NEW HARDWARE. AND/OR REPLACED TO BE IN COMPLIANCE WITH ADA. 6'-0" MAX SUPPORT WITH #12 WIRE AT 4'-0" OC OR 1" DIA CONDUIT EMT 9'-9" / WITH #10 WIRE AT 5'-0" OC EA WAY B. ALL TENANT ENTRY DOORS TO RECEIVE A NEW DOOR TSGL 162S125-33 MTL STUD 12'-0" WITH MORTISE LOCKSET AS DETERMINED BY LANDLORD. M AC K E N Z I E LATERALLY BRACE MAIN RUNNER TO 1-5 8"x2OGA DESIGNATION SPACING MAX WALL HEIGHT C. ALL SECONDARY DOORS TO HAVE DEADBOLTS REMOVED, DESIGN"RIVER I CLIENT FOCUSED NOTE: STRUCTURE AT 12'-0" OC EA WAY. BACK TO BACK 162S125-33 15'-0" 3625125-18 16" 12'-4" INSTALL COVERPLATES OR CHANGE DOORS AS AVAILABLE. ALL GRID MEMBERS AND BEGIN BRACING WITHIN 6'-0" OF MTL STUDS 1-5 8"x20GA 362S125-33 16" 14'-3" I D. ALL DOORS, FRAMES AND HARDWARE TO MATCH SUITE Client w STANDARDS, UNLESS NOTED OTHERWISE. CONNECTION DEVICES TO BE OF AN PERIMETER AND 2" FROM CROSS MEMBER SGL 250S125-33 MTL STUD 13'-6" m E. VERIFY IF EXISTING DOORS ARE HOLLOW CORE. REPLACE RUSSELL CONSTRUCTION APPROVED TYPE AND HAVE A 180# IN AREAS GREATER THAN 1,000 SF 2-1 2"x2OGA ¢ SECURE ALL HANGERS TO BLDG WALL TABLES ARE BASED ON WALLS SHEATHED BOTH SIDES FULL HEIGHT WITH I- IF REQUIRED TO MATCH BUILDING STANDARD SOLID CORE TUAL TI ,OREGON AVE CAPACITY. ALL LATERAL BRACING BACK TO BACK 2505125-33 15'-0" DOORS. TUALATIN,OREGON WIRES TO HAVE A 200# CAPACITY. STRUCTURE. TRAPEZE DUCT WORK MTL STUDS (2-1/2"x2OGA) 1/2" GYPSUM BOARD ATTACHED WITH #6 SCREWS MIN. AT 12"-0" O.C. MAX. = F. VERIFY DOOR HEIGHT DIMENSIONS. APPROXIMATE AND OTHER LARGE OBSTRUCTIONS 3 MEASUREMENTS BASED ON FIELD OBSERVATION. SUSPENDED CEILING BRACING z 2 WALL HEIGHT TABLE G. NEW DOORS MAY BE PULLED FROM EXISTING BUILDING INVENTORY OR RELOCATED WITHIN SUITE WHERE A81 NOTE: PROVIDE SEISMIC SEPARATION JOINTS IN CEILINGS GREATER NTS z A81 ¢ POSSIBLE. THAN 2,500 SF. PROVIDE HEAVY DUTY GRID SYSTEM. 3 ROOM FINISH SCHEDULE Project ROOM FLOOR BASE N. WALL E. WALL S. WALL W. WALL CEILING CEILING EDWARD JONES ATTACH STUD TRACK NO ROOM NAME MAT'L MATT MAT'L MAT'L MAT'L MAT'L HT FINISH SUITE 140 / THROUGH GRID TO GYP BD PARTITION SEE PLAN FINISH FINISH FINISH FINISH FINISH FINISH MAT'L COMMENTS TENANT / BRACE ABOVE 101 RECEPTION CPT RB P P P GB/P EXIST EXIST SOUND ATTENUATION BATT IMPROVEMENT SUSPENDED CLG AT ALL WALLS, TYP. / SOUND ATTENUATION BATT 102 HALL CPT RB GB/P -- P -- EXIST EXIST � / - ASSEMBLY / / AS OCCURS 103 HALL CPT RB P GB/P -- P EXIST EXIST LINE OF SILL AS OCCURS GYP BD WALL AS OCCURS 104 SERVER STORAGE CPT RB P GB/P P GB/P EXIST EXIST 1 LINCOLN ,IZ45' 105 OFFICE CPT RB P P P P EXIST EXIST 10300 SW GREENBURG RD - 106 OFFICE CPT RB P GB/P GB/P GB/P EXIST EXIST TIGARD,OREGON CUT TILE FOR TIGHT METAL STUD BRACING FINISH SCHEDULE NOTES: ABBREVIATIONS: ALUMINUM TRIM PIECE "CEE" D A� �5�" C�lf FIT AT WALLS TO FLOOR STRUCTURE AT 8'-0" W/ 1�" RETURNS, FINISH A. PATCH AND REPAIR ALL EXISTING WALLS WHERE CPT CARPET OC W/ (2) #8 SHEET METAL DOUBLE STUD AT JAMB, TYP AFFECTED BY NEW WORK. PAINT NEW AND EXISTING EXIST EXISTING CASING BEAD TO MATCH WINDOW FRAMES WALLS. REFER TO 1/A2.1 FOR ACCENT PAINT GB GYPSUM BOARD P L NG SCREWS AT EACH END. STUD SIZING ( LOCATIONS. CONFIRM FINAL PAINT SPECIFICATIONS WITH USG 200-A ANODIZED BUILDING PER SPAN TABLE. BRACING TO BE STANDARD) TENANT. P PAINT y SOUND ATTENUATION PROVIDED WHERE DISTANCE BETWEEN RB RUBBER BASE AT ALL NEW WALLS, TYP. DOOR FRAME; B. PROVIDE NEW FLOOR FINISH AND RUBBER BASE PERPENDICULAR INTERSECTING WALLS MATCH SUITE STD THROUGHOUT. POjty 0 E N HORIZONTAL BRACING BETWEEN NEOPRENE SEAL C. CONTRACTOR TO COORDINATE WITH TENANT AND SEE /l`` WALLS EXCEEDS 8'-0" OC ATTACHED TTAC TDINFORMENCE DRAWING FOR ADDITIONAL DITIONALPROJEO 0 *� GYP BD EA SIDE METAL STUDS SEE WALL HEIGHT SPECIFICATION REQUIREMENTS. TABLE FOR GAUGE AND SPACING CONT ACOUSTIC SEALANT STOREFRONT GLAZING © ALL CKENZ RESERVED EA SIDE AGAINST TRACK SYSTEM SCHEDULE OF INTERIOR FINISHES NO SEALANT AT SIM CCND THESE DRAWINGS ARE THE PROPERTY 1/2" MAX IOR OF MACKENZIE AND ARE NOT TO BE / CPT-1: PATCRAFT PRIVATE LABEL PRODUCT, C9 — CARPET P439Z-0 S USED OR REPRODUCED IN ANY MANNER, BOTTOM TRACK TO FINISH I WITHOUT PRIOR WRITTEN PERMISSION CONCRETE SLAB FLOOR W/ POWDER DRIVEN RB-1: ROPPE, 4" VINYL COVE BASE, B2-P147 LIGHT BROWN ANCHORS AT 4'-0" OC I REVISIONS: 3 P-1: SHERWIN WILLIAMS SW7723 COLONY BUFF, OR BENJAMIN MOOR, PUTNAM IVORY HC39, LD WALL AT EXTERIOR MULLION EGGSHELL FINISH Nr REVISIONS REVISION DELTA THIS CLOSING DATE NON-BEARING WALL 4 5 TYP INTERIOR DOOR w SHEET A8.1 AT FLOOR AND SUSPENDED CEILING 3"=1'-0" ¢ A8i 3"=1'-0" ¢ A8.i HEAD SIMILAR 3"=1'-0"o P-2: SHERWIN WILLIAMS SW 6195 ROCK GARDEN, OR BENJAMIN MOOR, CUSTOM "EDI GREEN", �� 3 3 o EGGSHELL FINISH t 1 3/4-CONDUIT TO LEC DMARC M.Comm Is IISpam NE ULL f SHEET TITLE: BOX KL 6 DOSt oaalrt MAY K Mn MMM WSr ME N=wN MWMEI' DETAILS, 3/4' CONDUIT TO ALL ft ON�a2 OF FOR M4F Cffl ) ELEVATIONS AND WORIMATiON LOCATIONS. V SCHEDULES 2'0'X 2'0'FRT PLYWOOD. PONIED TO SINGLE GANG PHONE BOX WITH MATCH WALL W/LIBEL EXPOSED. PULL SIRING AND 16 GROUND INSTALL AT 24'A.F.F.TO BOrM WIRE BY GC (INC TO RUN (1) BOARD SUPPUED&INSULLED BY GC. CA75E LINE TO THIS LOCATION) DEDICATED SIMPLEX OUTLET TO BE MARKED WITH T& ORANGE INDI fE DEDICATED BY GC. DRAWN BY: LER ACTME SINGLE GANG PHONE BOX DOLS GANG PHONE BOA, GC TO CHECKED BY: SBH, PDK WITH PULL STRINGS BY GC. INC SPUD RUN PULL SRNG NON EACH TO RUN REMAINING (4) CAME � � `CONDI W RR AREMAINYIG SHEET: LINES TO THIS LOCATION) TION LOCATIONS — SEE LAW VOLTAGE MW SPECS. A8.1 w 6 SERVER ELEVATION Joe No. 2150955.11 A8.1 ® SERVER/STORAGE 104 NTS W PERMIT SET: 12/4/15 LU •215095511•C:\TEMP\ACPUBLISH-536O\ll-A8.1.0.G LER 12/04/15 13:52 1:96.00