Specifications (18) , , Ffi6olag - O HYDRAULIC CALCULATIONSI 5-3 7G S w /T dt;4;-2 -1 for ` Job Information Project Name:Arlington Heights Lot#88 Contract No.: City: Tigard, OR 97223 Project Location: 15376 SW Arlington Terrace Date: 10/5/2013 Contractor Information Name of Contractor: Wyatt Fire Protection Address: 9095 SW Burnham Dr City: Tigard, OR 97223 Phone Number: (503)684-2928 E-mail:a.payne@wyattfire.com Name of Designer: Ashley Payne Authority Having Jurisdiction: City of Tigard Design Remote Area Name Arlington 88 Remote Area Location Occupancy Classification Density(gpm/ft2) 0.04 Area of Application(ft2) 648 Coverage per Sprinkler(ft2) 324 * Number of Calculated Sprinklers 2 In-Rack Demand(gpm) 0 Special Heads Hose Streams(gpm) 0 Total Water Required(incl.Hose Streams)(gpm) 27 Required Pressure at Source(psi) 66.9 Type of System Wet Volume-Entire System (gal) 3.6 gal Water Supply Information Date Location Source Notes \. 1 i File:C:\Users\Ashley\Documents\Projects\Arlington\88 c13 4502\Arlington 88 calc v.1.tyc3 Date 10/5/2013 Copyright©2002-2012 Tyco Fire Protection Products Page 1 Job:Arlington Heights Lot#88 Hydraulic Analysis for : Arlington 88 Calculation Info Calculation Mode Demand Hydraulic Model Hazen-Williams • Fluid Name Water @ 60F (15.6C) Fluid Weight, (Ib/ft3) N/A for Hazen-Williams calculation. Fluid Dynamic Viscosity, (Ib•s/ft2) N/A for Hazen-Williams calculation. Water Supply Parameters Supply 1 : srcl Flow(gpm) Pressure(psi) 0 118 1230 54 Hoses Inside Hose Flow/Standpipe Demand(gpm) Outside Hose Flow(gpm) Additional Outside Hose Flow(gpm) Other(custom defined) Hose Flow(gpm) Total Hose Flow(gpm) Sprinklers Ovehead Sprinkler Flow(gpm) 27 InRack Sprinkler Flow(gpm) 0 Other(custom defined)Sprinkler Flow(gpm) 0 Total Sprinkler Flow(gpm) 27 Other Required Margin of Safety(psi) 0 Base of Riser -Pressure(psi) 66.9 Base of Riser -Flow(gpm) 27 Demand w/o System Pump(s) N/A File:C:\Users\Ashley\Documents\Projects\Arlington\88 c13 4502\Arlington 88 calc v.1.tyc3 Date 10/5/2013 Copyright©2002-2012 Tyco Fire Protection Products Page 2 Job:Arlington Heights Lot#88. Hydraulic Analysis for : Arlington 88 OF Supply f System Demand II 150 I + 140 w__�_ y ; 120 — 110 f--- ��----® \, ,_ 100 ------- — ,�— N 8- D2 - \ va a) S2 s- kamemu60 E-----�,--_ -- '`G 47. i 50 ----- --- — 40 E ------- — 30 F:-------- — 20 E--- D1 i 3 0i 1..._-_______,____ ___ 0 400 500 600 700 800 900 1000 1100 1200 1300 Flow, gpm File:C:\Users\Ashley\Documents\Projects\Arlington\88 c13 4502\Arlington 88 calc v.1.tyc3 Date 10/5/2013 Copyright©2002-2012 Tyco Fire Protection Products Page 3 Job:Arlington Heights Lot#88 Hydraulic Analysis for : Arlington 88 Graph Labels Label Description Values Flow (gpm) Pressure (psi) S1 Supply point#1 -Static 0 118 S2 Supply point#2-Residual 1230 54 D1 Elevation Pressure 0 3 D2 System Demand 27 66.9 Curve Intersections & Safety Margins Intersection Safety Margin Curve Name Pressure (psi)(p ) Flow (gpm) Pressure (psi) @ Flow (gpm) Supply 117.9 37.1 51 27 Open Heads Required Calculated Head Ref. Head Type Coverage K-Factor Density Flow Pressure Density Flow Pressure (ft2) (gpm/psi1/2) (gpm/ft2) (gpm) (psi) (gpm/ft2) (gpm) (psi) h19 Overhead 324 4.9 0.04 13 7 0.043 14 8.2 Sprinkler - h20 Overhead 324 4.9 0.04 13 7 0.04 13 7 Sprinkler File:C:\Users\Ashley\Documents\Projects\Arlington\88 c13 4502\Arlington 88 calc v.1.tyc3 Date 10/5/2013 Copyright©2002-2012 Tyco Fire Protection Products Page 4 Job name:Arlington Heights Lot#88 Sheet number: PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added(q)* Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psis/z) (gpm) (in) (ft) (ft) (psi) (psi) h20 9 4.9 13 .75 12.16 150 7 h19 9 4.9 13 0.874 0 0.0939 0 12.16 1.1 h19 9 4.9 14 .75 1x(BM.Tee-Br)=3 2.88 150 8.2 n18 9 27 0.874 3 0.3641 0 5.88 2.1 n18 9 0 .75 lx(BM.90)=4 10 150 10.3 n17 19 27 0.874 4 0.3641 -4.3 14 5.1 n17 19 0 .75 lx(BM.Tee-Br)=3 2.5 150 11.1 n16 19 27 0.874 3 0.3641 0 5.5 2 n16 19 0 .75 lx(BM.Tee-Br)=3 3 150 13.1 n15 19 27 0.874 3 0.3641 0 6 2.2 n15 19 0 .75 lx(BM.Tee-Br)=3 5.17 150 15.3 n13 19 27 0.874 3 0.3641 0 8.17 3 n13 19 0 .75 1x(BM.Tee-Br)=3 4 150 18.2 n12 19 27 0.874 3 0.3641 0 7 2.5 n12 19 0 .75 11.83 150 20.8 h13 19 27 0.874 0 0.3641 0 11.83 4.3 h13 19 0 .75 18 150 25.1 h11 19 27 0.874 0 0.3641 0 18 6.6 hll 19 0 .75 1x(BM.Tee-Br)=3 20 150 31.7 n7 19 27 0.874 3 0.3641 0 23 8.4 n7 19 0 .75 lx(BM.90)=4 3.5 150 40 n9 19 27 0.874 4 0.3641 0 7.5 2.7 n9 19 0 .75 1x(BM.Tee-Br)=3 10 150 42.8 n6 9 27 0.874 3 0.3641 4.3 13 4.7 n6 9 0 .75 1x(BM.Tee-Run)=1 5 150 51.8 n4 9 27 0.874 lx(BM.90)=4 5 0.3641 0 10 3.6 n4 9 0 .75 lx(BM.90)=4 1.5 150 55.5 n3 9 27 0.874 4 0.3641 0 5.5 2 n3 9 0 .75 lx(coupling)=2.01 3 150 57.5 n2 6 27 0.874 2.01 0.3641 1.3 5.01 1.8 n2 6 0 1 lx(coupling)=1 2 120 60.6 - nl 4 27 1.049 1 0.2263 0.9 3 0.7 n1 4 0 1 2 0 62.1 Ames 200B 1" srcl 2 27 0 0 1.9675 0.9 2 3.9 ©2006 National Fire Protection Association Page 5 Job name:Arlington Heights Lot#88 Sheet number: PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added(q)* Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psis/z) (gpm) (in) (ft) (ft) (psi) (psi) * Discharge shown for flowing nodes only ©2006 National Fire Protection Association Page 6 Job:Arlington Heights Lot#88 Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psilh) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 1 h20 9 4.9 13 .75 12.16 150 7 h19 9 4.9 13 0.874 0 0.0939 0 12.16 1.1 h19 9 4.9 14 .75 lx(BM.Tee-Br)=3 2.88 150 8.2 n18 9 27 0.874 3 0.3641 0 5.88 2.1 n18 9 0 .75 lx(BM.90)=4 10 150 10.3 n17 19 27 0.874 4 0.3641 -4.3 14 5.1 n17 19 0 .75 lx(BM.Tee-Br)=3 2.5 150 11.1 n16 19 27 0.874 3 0.3641 0 5.5 2 n16 19 0 .75 1x(BM.Tee-Br)=3 3 150 13.1 n15 19 27 0.874 3 0.3641 0 6 2.2 n15 19 0 .75 lx(BM.Tee-Br)=3 5.17 150 15.3 n13 19 27 0.874 3 0.3641 0 8.17 3 n13 19 0 .75 lx(BM.Tee-Br)=3 4 150 18.2 n12 19 27 0.874 3 0.3641 0 7 2.5 n12 19 0 .75 11.83 150 20.8 h13 19 27 0.874 0 0.3641 0 11.83 4.3 h13 19 0 .75 18 150 25.1 h l l 19 27 0.874 0 0.3641 0 18 6.6 hll 19 0 .75 lx(BM.Tee-Br)=3 20 150 31.7 n7 19 27 0.874 3 0.3641 0 23 8.4 n7 19 0 .75 lx(BM.90)=4 3.5 150 40 n9 19 27 0.874 4 0.3641 0 7.5 2.7 n9 19 0 .75 1x(BM.Tee-Br)=3 10 150 42.8 n6 9 27 0.874 3 0.3641 4.3 13 4.7 n6 9 0 .75lx(BM.Tee-Run)=1 5 150 51.8 n4 9 27 0.874 lx(BM.90)=4 5 0.3641 0 10 3.6 n4 9 0 .75 lx(BM.90)=4 1.5 150 55.5 n3 9 27 0.874 4 0.3641 0 5.5 2 n3 9 0 .75 lx(coupling)=2.01 3 150 57.5 n2 6 27 0.874 2.01 0.3641 1.3 5.01 1.8 n2 6 0 1 lx(coupling)=1 2 120 60.6 n1 4 27 1.049 1 0.2263 0.9 3 0.7 File:C:\Users\Ashley\Documents\Projects\Arlington\88 c13 4502\Arlington 88 calc v.1.tyc3 Date 10/5/2013 Copyright©2002-2012 Tyco Fire Protection Products Page 7 Job:Arlington Heights Lot#88 Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psit/z) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 1 n1 4 0 1 2 0 62.1 Ames 200B 1" srcl 2 27 0 0 1.9675 0.9 2 3.9 srcl 66.9 * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. * Maximum Velocity of 14.45 ft/s occurs in the following pipe(s): (n18-h19), (n17-n18), (n16-n17), (n15-n16), (n11-nig) (n17_n111 (1111-n1/1 (hi1_h11\ (1-17_h11\ (nO_n7) (nFi_n0\ (nd_nI,) (nZ-nd\ (n7_nZ\ File:C:\Users\Ashley\Documents\Projects\Arlington\88 c13 4502\Arlington 88 calc v.1.tyc3 Date 10/5/2013 Copyright©2002-2012 Tyco Fire Protection Products Page 8 • Job:Arlington Heights Lot#88 Device Graphs Pressure vs. Flow Function Design Area: Arlington 88; Supply Ref.: srcl 130 120 110 100 90 ch Q 80 7 70 V! y 60 L a so 40 3o 20 10 0 0 0 0 0 0 0 0 0 0 O O O O O O O O O M N M V h D h 00 CT p N Row,gpm Pressure Loss Function Design Area: Arlington 88; BFP Ref.: BF1 (Ames 200B 1", Size = 1) 10 9 8 7 .y Q. 6 3 fA 3.9 psi @ 27 gpm 4- .. 3 2- 1 0 0 0 0 Row,gpm File:C:\Users\Ashley\Documents\Projects\Arlington\88 c13 4502\Arlington 88 calc v.1.tyc3 Date 10/5/2013 Copyright©2002-2012 Tyco Fire Protection Products Page 9 t co Fire Suppression & SuppftressiProducts rapid response° Technical Services 800-381-9312 I+1-401-781-8220 HOME FIRE SPRINKLER SYSTEM www.tyco-fire.com Series LFII Residential Sprinklers Flat-Plate Concealed Pendent 4.9 K-Factor The Series LFII Residential Flat-Plate General Concealed Pendent Sprinkler has a 4.9 Description (60,5)K-factor that provides the required residential flow rates at reduced pres- The TYCO RAPID RESPONSE Series sures,enabling smaller pipe sizes and . -42;,7 LFII Residential Flat-Plate Concealed water supply requirements. . V�it k, Pendent Sprinklers(TY2524)are decora- This sprinkler has been designed with r1• , tive,fast response,fusible solder sprin- - " ; heat sensitivityand water distribution klers designed for use in residential oc- characteristics proven to help in the con- ' ' cu ancies such as homes, apartments, �n p p trot of residential fires and to improve dormitories,and hotels. the chance for occupants to escape or The Cover Plate/Retainer Assemblycon- be evacuated. r 1 41,E,��� 1_, F � L� '`� , e�ary�,��"u'M3.',v,�,Y TG Fy... ceals the sprinkler operating compo- The Series LFII Residential Flat-Plate "�" "` ";:;.':1 .. nents above the ceiling.The flat profile Concealed Pendent Sprinklers are of the Cover Plate provides the optimum shipped with a Disposable Protective aesthetically appealing sprinkler design. Cap.The Protective Cap protects the Additionally,the concealed design of the sprinkler during ceiling installation or Series_LFII_Residential Flat-Plate Con -- __ = finish.=After ceilingmstallatiori is corn -----Technical ..... cealed Pendent Sprinklers provides 1/2 plete, the Protective Cap is removed inch(12,8 mm)vertical adjustment.This and the Cover Plate/Retainer Assem- Data adjustment provides a measure of flex- bly is installed. Removing the Protec- - ibility when cutting fixed pipe drops. tive Cap is required for proper sprinkler Approvals The Series LFII Residential Flat-Plate performance. UL and C-UL Listed Concealed Pendent Sprinklers are in- NSF-61 Certified tended for use in the following systems: NOTICE The Series LFII Residential Flat-Plate • per NFPA 13D, wet pipe residential The Series LFII Residential Flat-Plate Concealed Pendent Sprinklers are only sprinkler systems for one-and two- Concealed Pendent Sprinklers(TY2524) listed with the Series LFII Concealed family dwellings and mobile homes; described herein must be installed and Cover Plates having a factory-applied • per NFPA 13R, wet pie residential maintained in compliance with this doc- finish. p sprinkler systems for residential oc- ument and with the applicable standards cupancies up to and including four of the National Fire Protection Associa Maximum Working Pressure tion,in addition to the standards of any 175 psi(12,1 bar) stories in height;and authorities having jurisdiction. Failure •per NFPA 13, wet pipe sprinkler sys- to dd so may impair the performance Discharge Coefficient tems for the residential portions of of these devices. K=4.9 GPM/psi'" (70,6 LPMlbar'�) any occupancy. Owners are responsible for maintaining Temperature Rating their fire protection system and devices Sprinkler: 160°F(71°C) in proper operating condition. The in Cover Plate: 139°F(59°C) IMPORTANT stalling contractor or sprinkler manuVertical Adjustment Always refer to Technical Data facturershould be contacted with any 1/2 inch (12,7 mm) Sheet TF 700 for the "INSTALLER questions. WARNING" that provides cautions Finishes with respect to handling and instal- Model/Sprinkler Refer to the Ordering Procedure lation of sprinkler systems and corn- section. • ponents. Improper handling and in- Identification Physical al Characteristicsstallation can permanently damage a sprinkler system or its components • Cover Plate/Retainer Assembly: and cause the sprinkler to fail to Number (SIN) Cover Plate Copper • operate in a fire situation or cause it TY2524 Ejection Spring . . . . Stainless Steel to operate prematurely. Retainer Brass Page 1 of 6 OCTOBER 2010 TFP443 TFP443 Page 2 of 6 Horizontal Ceiling Sloped Ceiling Sloped Ceiling Minimum Flow(b)and Minimum Flow(biand Minimum Flowibland Residual Pressure Residual Pressure Residual Pressure Maximum Maximum (Maximum 2-inch rise (Greater than 2-inch rise (Greater than 4-inch rise Coverage Spacing for 12-inch run) up to maximum 4-inch up to maximum 8-inch Area °' rise for 12-inch run) rise for 12-inch run) 160°F(71°C) 160°F(71°C) 160°F(71°C) Sprinkler Sprinkler Sprinkler 12'x 12' 12' 13 GPM(49,2 LPM) 17 GPM(64,3 LPM) 17 GPM(64,3 LPM) (3,7 m x 3,7 m) (3,7 m) 7.0 psi(0,48 bar) 12.0 psi(0,83 bar) 12.0 psi(0,83 bar) 14'x 14' 14' 13 GPM(49,2 LPM) 17 GPM(64,3 LPM) 17 GPM(64,3 LPM) (4,3 m x 4,3 m) (4,3 m) 7.0 psi(0,48 bar) 12.0 psi(0,83 bar) 12.0 psi(0,83 bar) 16'x 16' 16' 13 GPM(49,2 LPM) 17 GPM(64,3 LPM) 17 GPM(64,3 LPM) (4,9 m x 4,9 m) (4,9 m) 7.0 psi(0,48 bar) 12.0 psi(0,83 bar) 12.0 psi(0,83 bar) 18'x 18' 18' 17 GPM(64,3 LPM) 22 GPM(83,3 LPM) 22 GPM(83,3 LPM) (5,5 m x 5,5 m) (5,5 m) 12.0 psi(0,83 bar) 20.2 psi(1,39 bar) 20.2 psi(1,39 bar) 20'x 20' 20' 20 GPM(75,7 LPM) 24 GPM(90,8 LPM) 24 GPM(90,8 LPM) (6,1 m x 6,1 m) (6,1 m) 16.7 psi(1,15 bar) 24.0 psi(1,65 bar) 24.0 psi(1,65 bar) (a)For coverage area dimensions less than or between those indicated,use the minimum required flow for the next highest coverage. area for which Hydraulic Design section under the Design Criteria are stated. (b)The Minimum Flow requirement is based on minimum flow in GPM(LPM)from each sprinkler.The associated residual pressures-.. are calculated using the nominal K-factor.Refer to"Hydraulic Design"in the Design Criteria section for details. TABLE A SERIES LFII RESIDENTIAL FLAT-PLATE CONCEALED PENDENT SPRINKLER(TY2524) NFPA 13D AND NFPA 13R HYDRAULIC DESIGN CRITERIA WET PIPE SYSTEMS • nkler/Support Cup Assembly: Design For systems designed to NFPA 13,the Body Brass _ _ number of design sprjjnklehs_is_to_be Cap •• -. -. :. . - .-Bronze=__ -- - -- .- - -the four most hydraulically--demanding -- - - Saddle Brass Criteria sprinklers.The minimum required dis- • Sealing Assembly Beryllium The TYCO RAPID RESPONSE Series charge from each of the four sprinklers Nickel w/Teflon' LFII Residential Flat-Plate Concealed is to be the greater of the following: Soldered Link Halves Nickel • Pendent Sprinklers (TY2524) are UL Lever Bronze flow rates given in Table A for NFPA Lever Screw Brass and C-UL Listed for installation in ac- 13D and 13R as a function of tern- CompressionDeflector Bronze cordance with the following criteria. perature rating and the maximum al- Guide Pin Housing . Bronze lowable coverage area Guide Pins Bronze NOTICE Support • minimum discharge of 0.1 GPM/ pP Cup Steel When conditions exist that are outside sq. ft. over the "design area" corn- the scope of the provided criteria, re- prised of the four most hydraulically fer to the Residential Sprinkler Design demanding sprinklers for actual cov- Operation Guide TFP49i7 for the manufacturer's erage areas protected by the four recommendations that may be accept- sprinklers When exposed to heat from a fire,the able to the Authority Having Jurisdiction. Cover Plate,which is normally soldered Obstruction To Water Distribution to the Retainer at three points, falls awayThe Series LFII Residential Flat-Plate to expose the S ri hr er/Su Concealed Pendent Sprinklers must obstruLocate.sprin s in accordance with the P p pport Cup As- obstruction rules of NFPA for residential not be used in applications where the ri sembly.At this point,the Deflector,sup- snklers as well as obstruction criteria air ported by the Guide Pins, drops down pressure above the ceiling is greater P to its operated position. than that below. Down drafts through described within TYCO technical data the Support Cup can delay sprinkler op- sheet TFP490. The Solder Link Element of the Sprinkler/ eration in a fire situation. Support Cup Assembly is comprised of Operational Sensitivity two link halves that are soldered togeth- System Type Install sprinklers relative to the ceiling er with a thin layer of solder. When the Only wet pipe systems may be utilized. mounting surface as shown in Figure 3. rated temperature is reached, the sol- Sprinkler Spacing der melts and the two link halves sepa- Hydraulic Design The minimum spacing between sprig- rate, allowing the sprinkler to activate Table A provides the minimum required and flow water. sprinkler flow rate for systems designed klers is 8 feet (2,4 m). to NFPA 13D or NFPA 13R as a function The maximum spacing between sprin- of temperature rating and the maximum klers cannot exceed the length of the allowable coverage areas.The sprinkler coverage area(Table A) being hydrau- flow rate is the minimum required dis- lically calculated; for example, a maxi- charge from each of the total number of mum of 12 feet for a 12 ft.x 12 ft. cov- 1 Registered trademark of Dupont "design sprinklers"as specified in NFPA erage area or 20 feet for a 20 ft. x 20 ft. 13D or NFPA 13R. coverage area. TrP443 Page 3 of 6 BODY /` SEALING (1/2" NPT) I /` ASSEMBLY CAP �ar4ih SADDLE j AREA 1 r SUPPORT �� �, i COMPRESSION CUP WITH 1 I ; SCREW i ROLL FORMED � 1 THREADS 11=1.41. , m ors �I �I �_all Itt LEVER WRENCH1 1. i, t � RECESS GUIDEPIN I '.���.' I SOLDER LINK I I ELEMENT hill t GUIDE PINMr i HOUSING i I - - I DEFLECTOR (OPERATED PUSH WRENCH DEFLECTOR ---- - I POSITION) IN TO ENSURE • I SPRINKLER/SUPPORT CUP I ENGAGEMENT ASSEMBLY WITH SPRINKLER I I WRENCHING AREA • THREAD INTO � � RETAINER SUPPORT CUP WITH THREAD UNTIL MOUNTING J j DIMPLES FIGURE2 SURFACE IS l% . p W-TYPE 18 o FLUSH WITH J EJECTION SPRINKLER WRENCH - --- _____ - ---. CEILING- - — - — — --SPRING------ --- • �_ SOLDER COVER PLATE/RETAINER COVER TAB ASSEMBLY PLATE • FIGURE 1 FLAT-PLATE CONCEALED PENDENT SPRINKLER(TY2524) . ASSEMBLY 2-1/2"DIA. • SPRINKLER- (63,5 mm) 1/2"(12,7 mm) FACE OF SUPPORT CUP 1/2" THREADED SPRINKLER ASSEMBLY NPT ADJUSTMENT FITTING / OPERATED �t �� SPRINKLER • 1 1 miw• �� ! 1-7/8"±1/8" .im PLATE �� _; (47,6 mm COVERUr? mal= I 1/8"GAP ±3,2 mm) RETAINER _ �� I I I (3,211 mm) j _lull \ = Imil _ - COVER- SPRINKLER- f MOUNTING 7/8"(22,2 mm) " RETAINER SUPPORT CUP 3/16" SURFACE 1-1/8"(28,6 mm) ASSEMBLY ASSEMBLY (4,8 mm) '� �- 3-3/16" DIA. DISPOSABLE DEFLECTOR IN (81,0 mm) TIP PROTECTIVE CAP OPERATED POSITION FIGURE 3 PROTECTIVE CAP AND ACTIVATED DEFLECTOR INSTALLATION DIMENSIONS TFP443 Page 4 of 6 Installation 6. Screw on the Cover Plate/Retainer Replace sprinklers that: Assembly until its flange contacts The TYCO RAPID RESPONSE Series the ceiling. •were damaged by dropping,striking, LFII Residential Flat Plate Concealed Do not continue to screw on the `^Tench twisting, wrench slippage, or Pendent Sprinklers must be installed Cover Plate/Retainer Assembly such the like. in accordance with the following that it lifts a ceiling panel out of its •were modified or over-heated. instructions, normal position. • are leaking or exhibiting visible signs NOTICE If the Cover Plate/Retainer Assembly of corrosion. cannot be engaged with the Mounting Responsibility lies with owners for the Damage to the Solder Link Element dur- Cup or the Cover Plate/Retainer As- inspection,testing,and maintenance of ing installation can be avoided by han- sembly cannot be engaged sufficiently their fire protection system and devices dling the sprinkler by the Support Cup to contact the ceiling,the Sprinkler in compliance with this document, as only;that is, do not apply pressure to the Fitting must be repositioned. well as with the applicable standards of Solder Link Element(Figure 1). the National Fire Protection Association Obtain a leak-tight 1/2 inch NPT sprinkler Care and (for example, NFPA 25), in addition to joint by applying a minimum-to-maxi- the standards of any other authorities mum torque of 7 to.14 ft.-lbs. (9,5 to 19,0 Maintenance having jurisdiction.Contact the install- Nm). Higher levels of torque can distort ing contractor or sprinkler manufacturer the sprinkler inlet with consequentleak- The TYCO RAPID RESPONSE Series regarding any questions. age or impairment of the sprinkler. LFII Residential Flat-Plate Concealed rec- Pendent Sprinkler (TY2524) must be Automatic sprinkler systems are Do not attempt to compensate for in- o maintained sufficient adjustment in the Cover Plate/ to be inspected, tested, accordance maintained and serviced in and maintained by a qualified Inspec- Retainer Assembly by under-or over- with the following instructions, tion Service in accordance with local tightening the sprinkler.Re-adjust the requirements and/or national codes. position of the sprinkler fitting to suit. NOTICE • 1. Install pendent sprinklers in the Before closing a fire protection system pendent position, with the center- main control valve for maintenance work line of the sprinkler perpendicular on the fire protection system that it con- to the mounting surface, trols,obtain permission to shut down the • affected fire protection system from the 2. Remove the Protective Cap. proper authorities and notify all person- 3. With pipe-thread sealant applied nel who maybe affected by this action. to the pipe_threads,-and-using the_. When_pr_operly installed there-is-a-nomi------ —_- -- - __"" -_____ W Type 18 Wrench in Figure nal 1/8 inch (3,2 mm)air gap between 2, install and tighten the Sprinkler/ the lip of the Cover Plate and the cell- Support Cup Assembly into the fit- ing,as shown in Figure 3.This air gap ting. The W-Type 18 Wrench ac- is necessary for proper operation of the cepts a 1/2 inch ratchet drive. sprinkler by allowing heat flow from a 4. Replace the Protective Cap by fire to pass below and above the Cover pushing it upwards until it bottoms Plate to help assure appropriate release out against the Support Cup. The of the Cover Plate in a fire situation.If the ceiling needs repainting after sprinkler Protective Cap helps prevent dam- age to the Deflector and Guide installation,exercise care to ensure that Pins during ceiling installation and/ the new paint does NOT seal off any of or during application of the finish the air gap.Failure to do so may impair coating of the ceiling, sprinkler operation. Absence of a Cover Plate can delay the sprinkler operation in a fire situation. As long as the protective Cap re- Do not pull the Cover Plate relative to mains in place, the system is con- the Enclosure.Separation may result. sidered"Out Of Service". Exercise care to avoid damage to sprin- 5. After the ceiling has been corn- .klers before, during,and after installa- pleted with the 2-1/2 inch (63 mm) tion.Never paint, plate, coat, or other- diameter clearance hole and in wise alter automatic sprinklers after they preparation for installing the Cover leave the factory. Plate/Retainer Assembly, remove Never repaint factory-painted Cover and discard the Protective Cap, Plates.When necessary,replace cover and verify that the Deflector moves plates with factory-painted units. Non- up and down freely. factory applied paint can adversely de- If the Sprinkler has been damaged lay or prevent sprinkler operation in the - and the Deflector does not move up event of a fire. and down freely, replace the entire Sprinkler assembly. Do not attempt to modify or repair a damaged sprinkler. TFP443 Page 5 of 6 Limited Ordering • Warranty Procedure Products manufactured by Tyco Fire Contact your local distributor for avail- Suppression & Building Products ability. When placing an order, indicate (TFSBP)are warranted solely to the orig- the full product description and Part in al Buyer for ten(10)years against de- Number(P/N). fects in material and workmanship when paid for and properly installed and main- Sprinkler/Support Cup Assembly twined under normal use and service. Specify: Series LFII Residential Flat- This warranty will expire ten (10)years Plate Concealed Pendent Sprinkler from date of shipment by TFSBP. No (TY2524), K=4.9, without Cover Plate/ warranty is given for products or com- Retainer Assembly,P/N 51-114-1-160. ponents manufactured by companies Cover Plate/Retainer Assembly not affiliated by ownership with TFSBP Specify: Cover Plate/Retainer Assem- or for products and components which bly with finish (below) for the Series have been subject to misuse, improper LFII Residential Flat-Plate Concealed installation,corrosion,or which have not Pendent Sprinkler(TY2524),K=4.9, P/N been installed, maintained, modified or (below): repaired in accordance with applicable Standards of the National Fire Protection chrome P/N 56-201-9-135 Association,and/or the standards of any Custom P/N 56-201-X-135 other Authorities Having Jurisdiction. Off White P/N 56-201-0-135 Materials found by TFSBP to be defec- tive shall be either repaired or replaced, Pure White* at TFSBP's sole option. TFSBP neither (RAL 9010) P/N 56-201-3-135 assumes, nor authorizes any person to Signal White** assume for it, any other obligation in (RAS 9003) P/N 56-201-4-135 connection with the sale of products or Standard White(Grey White) parts of products.TFSBP shall not be (RAL9002) P/N 56-201-5-135 responsible for sprinkler system design * Eastern Hemisphere sales only. errors or inaccurate or incomplete in- -• Previously known as Bright White. formation supplied by Buyer or Buyer's - representatives. Note: All Custom Cover Plates are _—_-peaeV=using Sherwin Williams Interior In no event shall TFSBP be liable,in con- Latex Paint. Contact TYCO Customer • tract,tort,strict liability or under any oth- Service with any questions related to er legal theory,for incidental, indirect, custom orders. special or consequential damages,in- cluding but not limited to labor charg- Sprinkler Wrench es, regardless of whether TFSBP was Specify W-Type 18 Sprinkler Wrench, informed about the possibility of such P/N 56-000-1-265. damages,and in no event shall TFSBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, express or implied. including warranties of mer • - chantability and fitness for a particular Purpose. This limited warranty sets forth the ex- clusive remedy for claims based on fail- ure of or defect in products,materials or components, whether the claim is made in contract,tort,strict liability or any oth- er legal theory. This warranty will apply to the full extent permitted by lam.The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. tqco Flow Tyco Fire Control Products 0 BlazeMaster & FIRE SPRINKLER PIPE FITTINGS SUBMITTAL SHEET • . . -uf TYCO FIRE PRODUCTS • 451 North Cannon Avenue • Lansdale, Pennsylvania 19446 www.tyco-fire.com TECHNICAL SERVICES TEL (800) 381-9312 • Fax: (800) 791-5500 E-MAIL:techserv@tycofp.com Ai ..1vtri,,r.cgast=sgswal I riArt,;:5 - . . No. 19-1.5 TD915 • 4-1.1.20 • 9/2001 . • • . w Introduction Tyco Fire Products (TFP) BlazeMaster®CPVC pipe and the same time, they provide superior heat resistance and fittings are designed exclusively for use in wet pipe strength as compared to traditional CPVC and PVC piping automatic fire sprinkler systems. They are made from a materials used in the plumbing trade. Various adapters are specially developed thermoplastic compound composed of available to connect CPVC pipe to metallic piping.All female post chlorinated polyvinyl chloride (CPVC) resin and state of pipe thread adapters have brass inserts for durability. the art additives. TFP BlazeMaster°CPVC products are Grooved adapters connect directly to grooved end valves easier to install than traditional steel pipe systems, and at and metallic pipe, with flexible grooved end couplings. Technical Data Sizes: 1/4"-3'' Manufacture Source: U.S.A. Maximum Working Pressure: 175 psi Material: Approvals: UL, FM, CUL, NSF, Dade County, LPCB, Pipe: ASTM F442, SDR 13.5 MEA, and the City of Los Angeles Fittings: ASTM F438 (Sch. 40) and Note: See current TFP BlazeMaster Installation Instructions and ASTM F439 (Sch. 80) Technical Manual,for exact listing/approval information Color: Orange Pipe Nom.Pipe Size Avg. O.U.Inches Avg. I.Q. Inches Wt. Lbs./Ft. Wt.Hz0 filled Pipe Lbs./Ft. Ft. of Pipe per Lift Wt.per Lift lbs. 3/4" 1.050 0.874 0.17 0.43 7875 1413 1" 1.315 1.101 0.26 0.67 5040 1320 11/4" 1.660 1.900 2.375 1.394 0.42 1.07 2835 1191 1'/:" 1.598 0.55 1.40 2205 1136 2" 2.003 0.86 2.20 1260 1063 2 '/2' 2.875 2.423 1.26 3.22 1215 1531 3" 3.500 2.952 • 1.87 4.79 720 1344 - Fittings • . • T,O T/O' ion T/O 11111..moi y.$` [ 45 Elbow �� T/O Reducinggipiii4.:. IV'° _ ��, - 90 Elbow -90°E1boW - -- illy -- _Nt__ T/OZ.- - - - -- T/0 I -1t i• i t ze T/O Wt. t T/O Wt. Part Size Sch. T/O Wt. 3 Size Sch. . 80050No. Si/<' 40Sch. /" 0.08 lb. ParNo. 1 2 Ib. 80025 No. /!" 40 9/,6" 0.09 lb. Par 80051 1" 40 3/e" 0.11 Ib. 80032 1"x 3/4" 40 "/,6" 13/,e" 0.16 80026 1" 40 3/<" 0.14 lb. 80052 11/+" 40 3/a" 0.20 lb. 80027 1'/4" 40 '/a" 0.21 lb. 80053 11/2" 80 '/,fi' 0.31 lb. 80028 11/2" 80 11/18" 0.40 lb. 80054 2" 80 3/4" 0.56 Ib. 80029 2" 80 17+" 0.79 lb. 80055 2'/2" 80 1/4: 0.89 lb. 80030 2'/2" 80 1'/2" 1.14 lb. 80056 3" 80 1.19 Ib. 80031 3" 80 113/18" 1.82 lb. i i II T/O' a , T/O I I I ,i I Tee _._. T/O Reducing . .. Crosse Cross EI T/O I I I T/O UO - , T/0 S T/O' MM. T/o' T/O MI T/O Part No. Size Sch. T/O Wt. Part T/O Wt. Part No. Size Sch. T/O Wt. 3 5 Size Sch. 0.11 Ib. No. 1 2 lb. 80009 3/." 40 '/16" 0.13 lb. 80001 1" 40 3/4" 0.19 lb. 80015 1"x 3/4" 40 11/e" 11/e" 0.28 80010 1" 40 15/16" 0.23 lb. 80002 11/4" 40 7/6" 0.26 lb. 80011 11/+" 40 15/16" 0.34 lb. 80003 11/2" 80 1" 0.51 lb. 80012 1'/:" 80 1'/i6" 0.67 lb. 80004 2" 80 13/e" 0.90 lb. 80013 2" 80 13/e" 1.00 lb. 80005 21/2" 80 19/,6" 1.59 lb. 80014 2'/2" 80 19/1e" 1.91 lb. 80006 3" 80 1"/,8" 2.41 lb. 80008 3" 80 113/6" 2.89 lb. NI IS 9002 ADCIEFITIRED C T/O T/O -I rio ii- Coupling Cap _ Reducer Bushing Part No. Size Sch. T/O Wt. e T/O 80200 1"x'/4" 40 7/16" 0.04 lb. 80075PartNo. 3/SizSch.+" 40 /T/Oe" 0.07Wt.Ib. Part 80100No. 3/Size4" Sch.40 5/, " 0.04Wt.Ib. 80201 1'/4"X 3/4" 40 7,6" 0.11 lb. 80076 1" 40 1/e" 0.11 lb. 80101 1" 40 3/a" 0.06 lb. 80202 1'14"x 1" 40 5/,6" 0.12 lb. 80077 1 74" 40 3/1a" 0.12 lb. 80102 1'/4" 40 1/2" 0.10 lb. 80203 112"x 3/1' 80 5/e" 0.16 lb. I 80078 11/2" 80 3/,6" 0.25 lb. 80103 1'/2" 80 5/e" 0.20 lb. 80204 1'/2"x 1" 80 '/2" 0.14 lb. 80079 2" 80 1/4e" 0.38 lb. 80104 2" 80 5/e" 0.31 lb. 80205 11/2"x 1'/4" 80 3/e" 0.17 lb. 80080 2'/2" 80 3/16" 0.67 lb. 80105 2'/2" 80 '/s" 0.58 lb. 80206 2' x 3/4" 80 3/4" 0.27 lb. 80081 3" 80 3/15' 0.91 lb. 80106 3" 80 1" 0.88 lb. 80207 2"x 1" 80 "/16" 0.26 lb. 80208 2"x 114" 80 9/,6" 0.24 lb. rio 80209 2"x 1'/2" 80 716" 0.19 lb. Grooved 80215 2'/2"x 1" 80 115/16" 0.42 lb. Coupling IN P,pe o. 80214 2'/2"x1'/4" 80 13/4' 0.45 Ib. Ada ter _�, --1 80213 272"x 1'2" 80 1W' 0.46 lb. P / 80211 21/2"x 2" 80 19/16" 0.29 lb. Part No. Size Sch. T/0 Wt. Pipe OD 80210 3"x 2" 80 2 3/,a" 0.72 lb. 80160 11/4"x 174" Grooved 40 2 5/16" 0.78 lb. 1'/4"(1.660") 80212 3"x 272" 80 115/16" 0.47 lb. 80161 1'/2"x 1'12"Grooved 80 2 5/16" 0.95 lb. 172"(1.900") . 80162 2"x 2" Grooved .80 2 5/16" • 1.42 lb. 2" (2.375") s , 80163 2'/2"x 2'/2' Grooved 80 2 5/16" 2.28 lb. 2'/2"(2.875") ��>-- 80164 3"x 3" Grooved 80 2'/4" 3.00 lb. 3"(3.500") Reducing ��� �' 80168 3"x 76.1mm Grooved 80 2'/4" 2.72 lb. 76.1mm (3.000") Tee 170' III T/0' iii _T./O.__ _-_-0 ..- -- .- - -- - - -- - �_ ___--____.--------�__.._Tr.�-: --_: ----=-Pat` =---__.--.__�=- _=-_ __-_ _-T/0...-- ---=:1wt._ No. Size Sch. 1 2 3 . lb. Female - Ilii _ 80132 3/4"x 3/4"x 1" 40 3/4" 3/4" 5/8' 0.14 Adapter � 80133 1"x 3/4"x 3/4" 40 72" "/,e" 3/4" 0.14' 80134 1"x 3/4"x 1" 40 5/e" 3/4" 3/4" 0.17 Part No. Size Sch. T/O Wt. 80260 1"x 1"x 3/4" 40 3/," 3/+" "/,6" 0.16 80142 3/4"x 3/4" NPT 40 5/a" 0.41 lb. 80145 1"x 1" NPT 40 80135 1'/4"x 1"x 3/4" 40 '/,6" 3/+" 15/,6" 0.21 3/4" 0.63 lb. 80136 1'/+"x 1"x 1" 40 "he" 3/," 15/,6" 0.22 80.146 1'/4"x 11/4" NPT 40 '/e" 1.03 lb. 80137 1'/+"X 1"X 1'/+ 40 13/,6" 15/,e" 3/,6" 0.26 80147 1'/2"x 11/2" NPT 80 1" 1.42 lb. 80261 174'x 174'x 3/4" 40 5/e" 5/6" 7/6" 0.23 80148 2"x 2" NPT 80 13/6" 2.66 lb. 80262 174"x 11/4"X 1" 40 3/4" 3/4' 7/e" 0.26 80138 11/4"x 1'/4'x 172" 80 1" 1" 1" 0.43 1/0 80140 172"x 1'/4"X 3/4" 80 '/2" 5/e" 1" 0.36 80141 1'/2"x 174"x 1" 80 1/2" 5/a" 1'/a" 0.38 Male __ __ 80263 11/2"X 11/2"x3/4" 80 9/,e" 9/16" 1" 0.36 Adapter 80264 1'/s"X 1'/2"X 1" 80 a/,e" 9/,e" 1" 0.38 80275 1 72"X 1'/2"X 174" 80 7/8" '/a" 1" 0.45 Part No. I Size Sch. T/O Wt. 80265 2"x 2"x 3/4" 80 3/a" 3/4" 13/6" 0.61 80266 2"x 2"x 1 80157 3/4"x 3/4" NPT 40 15/,a" 0.33 lb. " /a" 1 3 " /a 0.66 80 '/a" ' + 80158 1"X 1" NPT 40 13/e" 0.56 lb. 80274 2"X 2"X 174" 80 1" 1" 13/a" 0.74 80267 2"x 2"x 1'/2" 80 1'/6" 1'/a" 13/a" 0.78 T/O 80271 21/2"X 2'/2"x 1" 80 1"/18" 111,5"" 19/,a" 1.43 80272 2'/2"x 272"X 11/4" 80 1171e" 1"/,e" .19/,6" 1.46 Reducing _ __ _ _ 80273 21/2"x 272"x 1'h" 80 1"/,5" 19/,a" 1.48 Coupling _. 80276 2'/2"X 2'/2"X 2" 80 1"/,e" 1"/,e" 19/,a" 1.50 80270 3"x 3" x 112" 80 13/4' 13/4" 113/16" 2.28 Part No.I Size Sch. T/O Wt. 80268 3"x 3"x 2" 80 13/4" 13/4" 13/4" 2.25 80220 I 1" x 3/4" 40 /e" 0.08 lb. 80269 3"x 3"x 212" 80 13/4" 13/+" 115/,e" 2.44 170 170 Sprinkler Head Adapter gifilSprinkler Head Adapter ._. with Brass Threaded Insert with Brass Threaded Insert I � Part No. Size 1 Sch. T/0 Wt. 1 Part No. Size Sch. T/O I Wt. 80175E 3/4"x'/2" NPT 80 '/,e" 0.20 lb. 80175W 3/4"x'/2" NPT 40 '/,s" 0.19 lb. 80176E 1"x '/2" NPT 80 '/16" 0.22 lb. 80176W 1"x1/2" NPT 40 1/46" 0.18 lb. 80177WL 3/4"x'/2" NPT 40 9/1e" 0.16 lb. 80179 1 x 3/4" NPT 40 3/4" 0.43 lb. • T/& ow T/0 ""‘-4-,.ai VL.;..a• Sprinkler Head Adapter Back-to-Back Cross i u�i+• with Brass Threaded Insert ��� ��� (Spigot) _ T/°' ' with Brass Threaded Insert T/0' T/O+ Part No. Size Sch.I T/O I Wt. Part T/O Wt. 80177L 3/4"x 1/2" NPT 40 1/2' 0.16 lb. No. Size Sch. 1 2 lb. 80178 1"x '/2" NPT 40 '/2" 0.20 lb. 80462 1"x 1"x'/2"NPT x1/2"NPT 40 5/8" 11/e" 0.46 80463 1"x 1"x 12"NPT x 12"NPT 40 5/e" 15/6" 0.47 III Sprinkler Head Adapter To 90 Elbow A j ,-. ! with Brass Threaded Insert im T/°' Back-to-Back Tee T . �C� �; •I�i� _ • with Brass Threaded Insert I i T/0 2 T/0 2 Part i T/O 1 Wt. Part Size Sch. T/O Wt. No. Size Sch. 1 ---2- ,_Ib.= --- _.__No.__ - --- ------------- -=-- 1 -- 2---- Ib:--- 80199 3/4"x 1/2"NPT 40 5/s" 15/16" 0.20 80459 "I"x '/2"NPT x1/2"NPT 40 "/,e" 15/16" 0.48 80189 1"x '/2"NPT 40 13/16" 13/16" 0.26 80460 1"x'/2"NPT x'/2"NPT 40 "/16" 1'/e" 0.46 Part T/O Wt. No. Size Sch. 1 2 Ib. 80250 3/4"x 3/4"x1/2"NPT 40 5/e" 5/e" 13" 0.22 I 80251 1"x 1"X1/2"NPT 40 "he "As" 13/,6" 0.29 80249 1"x 1"x 1"NPT 40 15/,e" 15/1/3" Sprinkler Head Adapter "� T{d , „ " /18 Ws" 0.73 p p 80256 1 /. x 1 x'/z°NPT 40 '/,e" 9 ' " /,6' 1 /e 0.30 Tee — -- -- --1 80252 11/4" x 11/4"x '/2"NPT 40 7/16" 7/,6" 1'/e" 0.31 with Brass Threaded Insert -'- 80257 112" x 1'/4"x '/2" NPT 80 9/e" 5/s" 1'/ie" 0.43 T/0' I - I T/02 80254 1'/2" x 11/2"x 12"NPT 80 She 9/16" 17/16" 0.46 80258 2"x 11/2"x'/2"NPT 80 1/2" 5/e 15/6" 0.56 80253 2" x 2"x'/2"NPT 80 '/2" '/2" 15/6" 0.62 Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten(10)years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten(10)years from date of shipment by Tyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse,improper installation.corrosion,or which have not been installed,maintained,modified or repaired in accordance with applicable Standards of the National Fire Protection Association(NEPA),crnd/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced,c t Tyco Fire Products sole option. Tyco Fire Products neither assumes,nor authorizes any person to assume for it,any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE,IN CONTRACT,TORT,STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY,FOR INCIDENTAL,INDIRECT,SPECIAL OR CONSEQUENTIAL DAMAGES,INCLUDING BUT NOT LIMITED TO LABOR ' CHARGES,REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCT'S LIABILITY EXCh±.11 AN AMOUNT EQUAL TO THE SALES PRICE. t THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED,INCLUDING ` WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, tgca/F/o�v Control/PTyca Fire roducts - DynaNThreaci ' Full Line ch 40 Replacement Dyna-Thread"offers the life expectancy of&chair) with superior hydraulics and greater value. Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry,It combines The safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Comparison to Schedule 40 - Com NarisQn to t W T Ptpes': • Dyne-Thread's inside diameter is up . With its ineraased strength and lighter • More wall tbtckncea at the thread to 3.6%larger than Soh-40 giving it weight,Dyna-'thread reduces (CRt.,L00)gives Dyna-Thread�-Tire�aupctior hydraulics.And,when used installation fatigue and is ideal for better life expectancy than lightw allin combination with Dyna-Flow P1Pe• retre.fitappicationstlreadablc pipe Joints.dawn sizing ellen occurs. Corrosion Resistance Ratio(CRR)is a • Unlike lightwall threedable pipe, • Dyna-Thread is fully listed and UL(Underwriters Labors approved by UL,ULC,and FM ihrmay) a for Dyna-Thread has no thread gauge the estimated life expectancy of a pipe waffling, Sm sprinkler applications. joint.This is based en the calculated • The life expectancy of Dyna-Thread wall thioitnass at the base of the first • Dyna- is apptong for Dyne- and 3ch 40 arc equal based on the exposed thread.assumed to be the standard hanger spacing(15 ft, • calculated wall thicknesses per UL. weakest peiat of the pipe length.Dyna- way(can be used as safe to use 11 Thread and 3ch-40 have the same sway bracing, and is safe to use as • The consistent quality of steel used to calculated wall thiclmesaes at this point droPs' make Dyna-Thread thol itates smooth and are bath assigned the same CRR of threading and lower maintenance 1,00. Dyna-Thread is safer to weld on, costs, • Dyna-Thread is more widely • The exterior of Dyna-Thread is The internal suffuse of all black Allied accepted than lightwall threadable protected by a clean,durable mill Tuba&Conduit Fire Sprinkler pipe where 9vh-40 is specified. coating for extended shelf life and products up to 4.5000"in diameter is easy paint application. coated with our now Anv3acterial -Formula,"ABF",In scientific laboratory- test,ABS proved to have superior Specifications & Approvals., resistance to microbial colonization of 0 411e0/' 40 pipe walls,thereby delaying or possibly super 40/Dyna-Thread pipe is Preventing the onset of manufactured to meet:ASTIvI A-135, Listed Approved Listed Microbiologioally Influenced corrosion tirade A and is in compliance with (MIG)when the First Spainkler System NFPA-13.All sizes of Super 40/Dyna- is fast inattalled- Thread are rated at 300 psi working pressure.Super 40/Dyne-Thread is UL Specifications ULC Listed for wet,dry deluge and NPS NamMal I,R, Nfb Wt,(N20 FlII®d) Pas/ W1/1.1111211 pre'aotioa sprinkler systems and FM In;mm In;mm Lbs/W Kt1Rn Lbs Kg/rn is Lift Lbs;KWI/Lift(24') Wt/LIIt(25' Approved for use in wet systems.Super DLbs Kg Lbs;Kg 40/Dyne-Thread can be"hot-dip" I" 1.080 1.330 1,75 70 1965 2234 2327 galvanized to meet FM requirement for 25 274 2.0 2.80 70 887 1015 105: dry systems, Super 40/Dyna-Thread is 1v 1,408 1,870 2.54 51 2002 2288 2384 approved for all threaded couplings and 32 55.8 2.8 9,78 51 908 7038 i08 welded outlets and is suitable for all l'it' 1.539 2.290 3.82 44 2115 2418 251' roll-grooved,and plain-end fittings. 40 41.8 3.4 4.79 44 959 1097 114 (See listing information), 2" 2.104 3.050 4.57 30 1821 2198 2287 50 53.4 4.5 8.80 30 877 996 103 tile°/liocortuo� allied �( 16100 S.Lathrop•Harvey, IL 50425 Customer Service: / w [ (•J 11350 Noncom Rd,•Philadelphia,PA 19154 (800)882.5543 rues a=NOW 2525 N,27th Ave,•Phoenix,AZ 65009 Fax 708-338-1806 83.3 Submittal Data Sheet Dyna-Threa • s�,,,N��,� Full Line Sch-40 Replacement • Dyna-Thread sprinkle pias repseaents an engIeeering advancement for the sprinkler pipe industry.It combines the safety and lemgevity of traditional Soh-40 pipe with quality and superior hydraulic advantages, • Comparison to Schedule 40 Dyna-Threads inside diameter is up to 3.6%larger than Sch-40 giving it superior hydraulics.Also,when used in combination with Dyna-Flow pine,down siring often occurs.Dyna-Thread is fully listed and approved UL, ULC, - _ - -- :- '>._-: and FM for fire sprinkler applications.The life expectancy of Dyne Thread and Sch-40 -.";"•' --- � are equal based on the calculated wall thicknesses per U.L.The consistent quality _ - _ _ :' - steel used to make Dyne Thread facilitates smooth threading and lower maintenance =sm.The exterior of Dyne-Thread is protected by a clean,durable mill coating for • extended shelf life end easy paint application.With its inereased strength and lighter - "' weight,Dyne-Thread reduoea installation fatigue -- tigu creel is ideal for retro-fit applications. - Carrosion Resistance Ratio(CRR)is a UL(Underwriters Laboratory) I.- - - - - _ .t.---.- estimated term for the '� :.- : life cmpeatamey of a pipe joint.This is based cY+ the calculated wall thickness '":7:1`' ..- at the base of the fast exposed thread,assumed to be the wealmat point of the pipe length.Dyna-Thread and Soh-40 have the sane calculated wall thiakeesses at this c. l point and are both assigned the same CRR of 1.00. .; �,.t tl4 1� , tr . 1r, • Comparison to L.W.T.Pipe Mott wall t ndo:toes at the thread(CRR-1.00)giyea _ - - 4' Dyr> -Thread better life expectancy than lightwall threadable pipe joints.Un1S1a " : r• 44.1k .` lightwell threadablc Dgaugewarning Dyne-Thread to • -e, !' ,ix� pipe yea-Thread has no thread a D Thr PAe-a. .. - • '!. - +�. F30, approved for standard hanger spacing(15 ft.O.C.),can be used as earthquake sway •� z braoing,•and is safe to use at drops.D "' ti 4 '":' Dyna-Thread fa safer to weld an than maty '�'�'" -"+ . ,. � ,�": coated Iightwall thrcadable a rode �°- '$t : `t4.ii ;':r:;,;:":i�:::: lightwall threads here Sah•40 '�:' pipe products.Dyna-Thread ie more widelyaccepted than .,„;�i.Yl; _ k�:,t�•;;,..�_di` �. Isle w is specified, ' ". ,+?t.,, .N7is:: Specifications&ApprovaIs Super 40/ Dyna-Thread pipe is manufactured to Specifications manufactured meet:ASTM A 135,Grade A and is in UPS Hsmisal 1.0. Wt. Wt.(H20 Filled). Peri WWII(21') Wyilt(24') W1/1111(25' compliance with NFPA-13.All sizes of In:mm hr mm Lbvft 141.0 Leek?'K•I1n Luff Lbs;Kg Lbs;Kg L,. K. Super 40/Dyne-Thread are rated at 300 1' 1.08D 1.330 1.75 . 70 1955 2234 232 psi working pressure.Super 40/Dyne- 25 27.4 2,0 250 70 887 1013 105; Thread is UL and ULC Listed far wet, _ -- - -— — -- - - - -- - - --1W 1.4°8-- -- --1.870----- - 2 -- -...-51: -.__ 2002- -2288 238. 32 dry and pm-action.sprinkler systems and 8 28 3.78 51 808 1098 106 • FM Approved for use in wet systems. Super 40/Dyne Thread oast be"hot-dip" 1W 1.639 2.290 3,22 44 2115 2418 251! galvanized to meet FM requirement for 40 41.6 3.4 4.79 44 959 1097 11• dry systems.Super 40/Dyna-Thread is 2' . 2.104 3.050 4.67 30 1921 2196 228 approved for all threaded couplings and 60 53.4 9,5 6.80 30 871 998 103 welded outlets and is suitable for all roll- grooved,and plain-end fittings.(Seo American Tube and Pipe was acquired by Allied Tube end Conduit on.February 1, listing informality), 1997.The engineered ligbtwall end standard wall family of products although they The internal surface of all black Fire havediiiixrrt names arc the same in all respects with regard to strength,weight, Sprinkle pipe up to 4.5000"in diameter bundle count,listings and approvals.For example, shall be coated with Allied Tube& Dyna-Flow and Super Flo arc the mune product as 411 44> CD Conduit Antibacterial Formula"ABF", are Dyne ThreadSuper 40.XL is manufactured with Exterior galvanized coating.BLT is manufactured with Black lacquer coating Listed Approved Listed Project: Sprinkler contractor: starts: Engineer, Specification Reference: System Typs: Locations: comments: - S3-4 P0TFERSMALL FOR PIPE VSR-S VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD UL,ULC,CSTM Listed and NY119EA Accepted Service Pressure: Up to 300 PSI(20,7 BAR) Flow Sensitivity Range for Signal: 4-10 GPM(15-38 LPM UL Maximum Surge: 18 FPS(5,5 m/s) Enclosure: Die-cast,red enamel finish Cover held in place with tamper resistant screws Contact Ratings: Two sets of SPDT(Form C) • 10.0 Amps at 125/250 VAC - 2.0 Amps at 30 VDC Resistive 10mAmps min.at 24 VDC Conduit Entrances:Two openings provided for 1/2"conduit. Individual switch compartments suitable for dissimilar voltages. Usage: Listed plastic,copper and schedule 40 iron pipe Fits pipe sizes- 1"(25mm), 1 1/4"(32mm),1 1/2"(38mm) and 2"(50mm) Stock No. 1144440 Note:12 paddles are furnished with each unit,one for each pipe size of threaded and sweat TEE,one for 1"(25rmn)CPVC, one for 1"(25mm)CPVC(Central),one for 1"threaded Nibco CPVC,and one for 1 1/2"(38mm)threaded(Japan). i N -' �4, °; Environmental Specifications: • NEMA-4/1P54 Rated enclosure suitable for indoor or outdoor Installation must be perfomed by qualified personnel and in use with factory installed gasket and die-cast housing when used accordance with all national and local codes and ordinances. with appropriate conduit fitting. Shock hazard. Disconnect power source before servicing. • Temperature range:40°F to 120°F,(4,5°C to 49°C)UL Serious injury or death could result. Service Use: Risk of explosion. Not for use in hazardous locations. Serious Automatic Sprinkler NFPA-13 injury or death could result. One or two family dwelling NEPA-13D Residential occupancy up to four stories NEPA-13R National Fire Alarm Code NFPA-72 Optional:Cover Tamper Switch Kit,Stock No.0090148 (See Fig.7 for terminations) Replaceable Components:Retard/Switch Assembly,stock no. 1029030 The Model VSR-S is a vane type waterflow switch for use on wet Installation sprinkler systems that use 1"(25mm),1'4"(32mn).11/2"(38mm)or 2" These devices may be mounted in horizontal or vertical pipe. On (50mm)pipe size.The unit may also be used as a sectional waterflow horizontal pipe they should be installed on the top side of the pipe where detector on large systems. they will be accessible.The units should not be installed within 6"(15cm) The unit contains two single pole double throw snap action switches and of a valve,drain or fitting which changes the direction of the waterflow. an adjustable, instantly recycling pneumatic retard. The switches are Select the proper paddle for the pipe size and type of TEE used see Fig. actuated when a flow of 10 gallons per minute(38 LPM)or more occurs 1 for instructions on changing paddle.The unit has a 1"NPT bushing downstream of the device.The flow condition must exist for a period of for threading into anon-con olive TEE.See Fig.2 for proper TEE size. type and installation.Use no more than three wraps of teflon tape. time necessary to overcome the selected retard period. Enclosure Screw the device into the TEE fitting as shown in Fig.2.Care must be The V SR-S switches and retard device are enclosed in a general purpose, taken to properly orient the device for the direction of waterflow. die-cast housing.The cover is held in place with two tamper resistant The vane msrst not rub the inside of the TEE or bind in any way.The screws which require a special key for removal.A field installable cover stern should move freely when operated by hand. tamper switch is available as an option which may be used to indicate The device can also be used in copper or plastic pipe installations with unauthorized removal of the cover: See bulletin number 5401103 for the proper adapters so that the specified TEE fitting may be installed installation instructions of this switch, on the pipe run. Note:Do not leave cover off for an extended period of time. Potter Electric Signal Company,LLC•2081 Craig Road,St.Louis,MO,63146-4161•Phone:800-325-3936'Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MFG.85401206-REV G PAGE]OF 3 12%0$ POR SMALL PIPE VS R-S _ P P0UFR VANE TYPE W4TERFLO\% The Symbol of Protection ALARM SWITCH WITH RETARD Fig. 1 Fig.2 Retard Adjustment DO NOT ERA,,ECO\'IROPIlORC'TRNDEDPERIOD Of7IIdE r Ow =.Mht .eP11101 The time delay is factory set at 30+10 seconds. COVER TAMPER SWITCH The delay can be adjusted by rotating the retard 1 ..1 -3 1- 90 adjustment knob from 0 to the max setting(60- ������ � I DEPTH I 90seconds).Thetimedelayshouldbesetatthe ,0 j. minimum required to prevent false alarms. --4 _ ;F3 1 fito g ,Iraq MOUNT SO `�I r/� WATER,EUN. --�iOl�r` device for the direction of l��aterflow.On sweat <3,ii# I ARROW ' .:", IN D1RECHONOF tees,no threaded bushings,inserts,or adapters RT DIRECTION OF \: «:rE,rEow' 1 1111 are permitted,unless they comply with the dimensions listed in the chart below. ""`""-, 1"NPT Important-The depth to the inside bottom of THREADED PITTING ON �".•� the tee should have the following dimensions: t 4 , ALL SIZES ��'� RUN OF n�IEE €::- ..:,) � Approximate Depth Requirnnent RIAS HE There are 12 paddles furnished with each unit. THREADED OR ���� Tee Size nxesaea s},e:it CPUC SWEAT PIPE One for each size of threaded sweat or plastic 1^,i.,1" 21,1C 13,4" 2716" DIRECTION OF (a. TEE as described in Fig.2.These paddles have n ArFRn ov.� t\\� I I�I'•x11,4"t I' 27,1,a" 27/16" N 4 raised lettering that shows the pipe size and type IA%0,b2.3. 11 2",1 1_',I" 2 11116" 21/4" NA lir of TEE that they are to be used with.The proper _„, ,1° 3316" 234" N'A paddlemust.beused Thepaddlemusl.beproperly Shown with optional Cover Tamper Switch Kit, attached(see drawing)and the screw that holds .='''AWARNING '` the paddle must be securely tightened. Do not INC more than three wraps of teflon tape. Fig.3 Switch Terminal Connections Clamping Plate Terminal Fig.7 Cover Tamper Switch Wiring (Shown with cover in place) `- 4(...,,,,„...c., . 11R114��lilLftl a • /,I... • An=insulated section of a single conductor should not be looped o, around the terminal and serve as two separate connections.The wire © 4) 60 " I,WCr-923 .:: must be severed,thereby providing supervision of the connection in o"' the event that the wire become dislodged from under the terminal. C N.O. N.C. Failure to sever the wire may render the device inoperable risking (WHT) (RED) (BLK) severe property damage and loss of life, D\ww98100/9.2 Fig.4 Typical Electrical Connections Fig.5 Fig.6 �I- To remove knockouts: Breakout thin sectionofcoverwhenwiing ® NrnIZ Dc oR Place screwdriver at edge of both switches from one conduit entrance. �® ,+� EF_LL Nrl�rIU1L AC b knockouts,not in the center. POSITn\E DC OR — '':_!� HOT Af.' \ ( ) • ::.—r1 I16.: iLl 71. -`• wAn Iu LOSc ZONE ON • APOP'�`I\': \® ''O +, j" I nice PANEL ,+L `\�-J1 frx- ;Votes: 4 I I. The Model y'SR-5 has two switches,one can be used to operate a 1 central station.proprietary or remote signaling unit,while the other 1�® is used to operate a local audible or visual annunciator. 2. For supervised circuits see"Switch Terminal Connections-drawing 4 - and caution note(Fig.3). PRINTED 11'r USA MFG.i5t401206-REV G PAGE 2 OF 3 12'O8 FOR SMALL PIPE V S R_S VANE TYPE WATERFLOW • The Symbol of Protection ALARM SWITCH WITH RETARD Testing Removal The frequency of inspection and testing for the Model VSR-S and its • To prevent accidental water damage,all control valves should associated protective monitoring system should be in accordance with be shut tight and the system completely drained before waterflow applicable NFPA Codes and Standards and/or the authority having detectors are removed or replaced. jurisdiction(manufacturer recommends quarterly or more frequently.) • Turn off electrical power to the detector,then disconnect wiring. An inspector's test vah-e(usually located at the end ofthemostremote branch • Use a wrench on the flats of the bushing.Turn the switch line)should always be used for test purposes.If there are no provisions for counterclockwise to disengage the pipe threads. testing the operation of the flow detection device on the system,application • Gently lift with your fingers,roll the vane so it will fit through the of the VSR-S is not recommended or advisable. hole while continuing to lift the waterfiow detector. A minimum flow of 10 gpin(38 Lpm)is required to activate this device. • Lift detector clear of pipe. NOTICE Please advise the person responsible for testing of the A CAUTION fire protection system that this system must he tested in accordance with CAUTION the testing instructions. Waterfdow switches that are monitoring wet pipe sprinkler systems Maintenance shall not be used as the sole initiating device to discharge AFFF, Inspect detectors monthly for leaks. If leaks are found, replace the deluge,or chemical suppression systems.Waterfl ow switches used detector.The VSR-S waterfiow switch should provide years of trouble- for this application may result in unintended discharges caused free service.The retard and switch assembly are easily field replaceable. by surges,trapped air,or short retard times. In the unlikely event that either component does not perform properly, please order replacement retard switch assembly stock#1029030.There is no maintenance required,only periodic testing and inspection. Mounting Dimensions 3.50" - 5.56" • GROUND SCREWS (89.0 mm) (141.2 mm) - 0"O t I .tit/ .82.m ragliti). mum (50.8 mm) 2.34" !iJI 1 _ _1 �_�_ 4.89" EINIIIIIIIIIM=�O _ _ ��i.;=r.� (52.3 mm) 111 lei ,. u u w i ,0 1"-II 1/2 NPT 11 II DWG#1206-5 PRINTED UN USA MFG. 5401206-REV G PAGE 3 OF 3 l✓OF A/ F TES TESTANDRAI N DRAI • gne � � � t� 'tc S i t F4 rd l; 3 wr`e4� t, is��'az Y' aLr �psa3g � ,��f�.k FA, f, 1 x oaf N NT� �t 2•X� n heft e6 SC # in � '� i t� � � p nyeff 1�x� s�l��`'"� �Lst�rr ��i1FkF�'� k 1 .. ^.....,.�. � rey }� 9t �i setstt ` mtn q� � i 't} i� 9 f 71,7' k+fig Jst� "row .ui r^tr p _ C r t,.un tp i n t , ' d''"`. }.9r k rt A'.,` aE"; p1 rF- ,�0;0%,i4 4�ipnfvY i sa U f1 �S.nr l�idr� iat ft 4 �. fiN L1,� da ? F}wr9 r a 3IF-t: . f '91t4d CFi 3i s °f fj t At i40' V it t f Int C� 1 �k kJ.�.�'lort ila.4.7; �qu,�rrp ent.Paur,i-- fr � e ����.;. � �t 1.1'11) —0 • • frj rxi 'r i rf Of' . ll CS�,i...4m.3..�L:.h..it�.•..,.�+..uw ..�.(I.w��...�L,w.aw�.. w. e�` • ■ The AGF Manufacturing Co., Inc. Model 1000 has been designed to provide both the Test Function and the Express Drain Function in a multi story installation. ■ Complies with all requirements of NFPA-13, and NFPA-13R ■ Complies with all requirements of NFPA-13D (HOUSING) ■ Positive Shut Off O Single Locking Handle • Tapped '/Z" for Pressure Gauge • Tamper Resistant Orifice permanently installed • Available with all required Orifices • • Orifice size noted on Indicator Plate • Lightweight and compact (114" weighs 5 lbs.) • 300 PSI Rating • Fused, tempered, tamper resistant Sight Glasses 0 II • Ill • II 1 i i - - TESTANDRAIR iffi • 3/411 * ■ 1 " ■ 1 1/4 " ' 1 1/2 II ■ 2 " _ *'h"NOT FM APPROVED PLAN VIEW FRONT VIEW A tFROM LICA\ BRANCHGAUGE OUTLET e --0.....--mil RI PROVIDED III iri r TO DRAIN C /11111 ( 0! =' ' IMI GAUGE OFF n lit[O� IT " STREET EL1 m� DRM3 1 lino 1 FRONT VIEW/HORIZONTAL INSTALLATION. STREETEL�+ i TO DRAIN E1 -� II lain -_ F _� �• TEST TO DRAIN 0 '---- ' z, • < N o \ FOR RIGHT HAND/STRAIGHT INSTALLATION TO DRAIN " �IIIIII.._ ....--_- _ _.___ __. .__.. _.__ ' �1I o o APPROVALS • I 0 ■ UL and ULC Listed We nom Nmed ■ FM Approved except 3/4" ■ NYC BD. of S&A CAL. NO. 720-87-SM • CA. State Fire Marshall ORIFICE SIZE PROVIDED-3/8-7/16—1/2-17/32-55/8**-3/4** DIMENSIONS—INCHES MATERIAL LIST SIZE A B C D E F G H PART MATERIAL 3/4 5'/,6 13/4 23/B 4'/e 33/8 13/4 49/16 65/i6 HANDLE STEEL STEM ROD BRASS 1 5'/6 13/4 23/8 4'/8 33/a 13/4 49/16 65/6 BALL C.P. BRONZE 17/4 57/6 13/4 27/8 45/B 35/6 115/16 57/2 77/,6 BODY BRONZE VALVE SEAT GLASS INPREGNATED TEFLON 1 '/2 67//6 13/4 3"/I6 57/6 3'/z 23/B 8'/6 10'/16 INDICATOR PLATE STEEL 2 67/I6 13/4 3"/16 57/16 3'/z 23/B 81/16 107/16 HAND' LOrK SPRING STEEL SIGHT GLASS (2) FUSED TEMPERED GLASS ** Available on 11/4"to 2"size units only. AGF MFG. CO. JOB NAME: l 'Box 4437, 150 Mt. Bethel Rd. ____ Warren, N.J. 07059-0437 ARCHITECT: MADE IN U.SA. Telephone (908) 604-6471 ENGINEER: Fax (908) 604-6501 CONTRACTOR: 1000 8/94 r - IOLCO 0 • INCORPORATED CORONA,CA (909)737-5599 • 0 c® Fig. 27 & 27A "Stand-Off" Hanger/Restrainer for CPVC Plastic Pipe Size Range-3/4" & 1" CPVC Plastic Pipe*. Material- Carbon Steel, Pre-Galvanized. Ti Function-Designed to be used as a hanger/restrainer**for CPVC piping \ -' where the "stand-off' design will ease installation by eliminating the need for \., wood blocking. Features: I • • Rared edge design protects CPVC from any rough or abrasive surfaces. \ / • Snap-in retainers hold pipe firmly in place during installation. li • The "Stand-Off'design eliminates the need for wood block extension. • Can be installed on horizontal or vertical piping regardless of mounting Fig. 27 surface orientation. • Attaches easily to wood structure with 2 hex head self-threading screws furnished with product. • Installs easily using rechargeable electrical driver with 5/16"sockets, eliminating impact tool damage to pipe ° Approvals- Underwriters Laboratories Listed in the U.S. (UL) and Canada o (cUL) to support automatic fire sprinkler systems. Meets and exceeds the 1 ' ;requirements of NFPA 13, 13R, and 13D. Fig. 27A • **Important Note-When installed in slot opening on_Fig.27, Fig_,27A _____, _._ ` r:____ - provides additional stability and satisfies the UL vertical restraint requirement where needed. Order By-Fig. 27: By figure number and CPVC pipe size. \' \ Fig. 27A: By figure number and CPVC pipe size. i / U.S. and International Patent application in process. I *for other sizes consult factory. 1� Fig. 27 and Fig. 27/27A have also been tested by U.L. mounted on 3/8" ' composite wood web material (such as TJI Series/Trus Joist MacMillan) Fig. 27/Fig. 27A without the use of back up wood blocking. When using Fig.27 & 27A in Combination combination on 3/8"web to satisfy the UL requirement for vertical restraint, install 2 reinforcing speed nuts (Fig. 27B). Fig. 27B is UL Listed only. when. G.27 W/FIG.27A used with Tolco products. ■-.Is FIG.27B � w FIG.27 I feta W/FIG.27A ■.• ! ■�= C FIG.27 FIG.27 FIG.27 FIG.27 W/FIG.27A III FIG.27 • T� 11TY Illtil 11 -0 V Typical Applications rtrg CS-A-2000B :,-:: --:.:::: : : -. , -::: ,- - - i .- A . . . _ . .. Series 2000B :-."-: 1 (� � 1, A NI E S Double Check Valve Assemblies .. :..... FIRE&WATERWORKS'' Sizes lit" -2" (15-60mm) 5::::,_: .. '"� S e Features ; • Ease of maintenance with only one cover 20008 HC • Top entry2"(50mm) • Replaceable seats and seat discs • Modular•construction : E • Compact design +. '/z' 2 (15 50mm)•Cast bronze ,' h body construction �, • ,8 •J'/"20006.::, Top mounted ball valve test cocks Low pressure drop (20mm) • No special tools required _ ;: Series 20008 Double Check Valve Assemblies shall be installed at referenced cross-con- • '/z 1" (15-25 mm)have nections to prevent the backflow of polluted water into the potable water supply.Only tee handles those cross-connections identified by local inspection authorities as non-health hazard shall be allowed the use of an approved double check valve assembly. Check with local authority having jurisdiction regarding vertical orientation,frequency of Available Models testing or other installation requirements. f' Suffix: These valves meet the requirements of ASSE Std. 1015 and AWWA Std. C510 and are 1 ` _B= Quarter..turn.ball_valves______ _approved by the Foundation for_Cross_Connection Control and_Hydraulie Research-at the • LBV- less ball valves University of Southern California.- LH- locking handle ball valves(open position) Specifications SH- stainless steel ball valve handles HCAssembly shl be installed at each notd location.The 2W inlet/ouflet fire hydrant fitting shAall consist of twoouble Checklve positive seating check modules with captured springs and rubberbly seat (2"valve) discs.The check module seats and seat discs shall be replaceable.Service of all internal Prefix: components shall be through a single access cover secured with stainless steel bolts.The U union connections assembly shall also include two resilient seated isolation valves and four top mounted, re- silient seated test cocks.The assembly shall meet the requirements of ASSE Std. 1015 and AVVWA Std.C510.Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California.Assembly shall be an Ames Pressure — Temperature Temperature Range:33°F-140°F Company Series 20008 (5°C-60°C) Approvals Maximum Working Pressure:175psi (12 bars) t ASSE,IAPM0,CSA,UPC A. Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California. Standards • Model LBV is not listed. ASSE Std. 1015,AWWA Std. C510 u UL Classified(LBV models only)3/4"-2"(19-50mm) IAPMO PS31, CSA B64.5 . Horizontal and vertical "flow up"approval on all sizes. e� pp � SP �o 42) Job Name Contractor Job Location Approval Engineer Contractor's P.O.No. _ Approval Representative Ames product specifications in U.S.customary units and metric are approximate and are provided for reference only.For precise measurements,please contact Ames Technical Service.Ames reserves the right to change or modify product design,construction,specifications,or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames products previously or subsequently sold. www.am esfi rewater.corn Dimencions - Weights Witi erg.11._i; ..= �� 1111�,� B . 0 0 1 WI, F H __Ir-4-I G Suffix HO-Fire Hydrant Fittings dimension "A"=231/2"(594mm) Size(DN) A B Dimensions Weight Model in. mm in. mm in. mm in. mm in. F mm in. G mm in. H mm in. I mm lbs. kgs. 2000B Y 15 10 254 4% 117 23/46 62 5 127 3% 85 236 59 21/16 52 4.5 2 2000B M3 3/4 20 11% 282 4 102 31/s 79 63/15 157 33/46 87 2% 54 15/6 33 5 2.3 20008 1 25 13% 337 51/s 130 4 102 7% 191 3% 85 1"A6 43 11/6 43 12 5.4 20006 1'% 32 16% 416 5 127 35/6 84 9% 241 5 127 3 76 2 50 15 6.8 2000B 1'% 40 163/4 425 4% 124 314 89 93/4 248 513/46 148 31/s 79 21/6 68 15.86 7.2 20006 2 50 19% 495 6% 159 4 102 13% 340 6% 156 33/46 87 213/46 68 25.75 11.7 Strainer sold separately Capacities bars As compiled from documented Foundation for Cross-Connection Control 1 74 f�4 (32mm) and Hydraulic Research at the University of Southern California lab tests. y .8 12 'Typical maximum system flow rate(7.5 feet/sec.,2.3 meters/sec.) .5 8 cobars psi •`(15mm)F+4* N .3 4 111111111411•1111111111imEingililliglill11 N .8 12 ca 0 .7 10 .- .1 2 m .5 8 ° D 0 Cl)i ,3 q ti 0 10 20 30 40 50 60 70 80 90 100 110 120 gpm w eP 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm a-QO 5 7.5__10- - 15 �.E - fps 1.5 2 3 3.0 4.6 - _ 0 2 4 6 8 10 12 gpm mps AP 0 7.6 15.2 22.8 30.4 38 45.6 1pm Flow Rate 155 7.3 10 fps bars psi 11h"(40mm) * 3.0 mps .8 12 bars psi 3/a"(20mm) Flow Rate N y 1.5 22 * 3 .7 10 m .5 8 1.2 18 y .4 6 .96 14 .3 Cl) 4 .69 10 a .1 2 .41 6 eP0 10 20 30 40 50 6D 70 80 90 100 110 120 gpm a o 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm .14 2 5 7.5 10 15 fps AP 0 5 10 15. 20 25 30 35 40 45 50 gpm 1.5 2.3 3.0 4.6 mps 0 19 38 57 76 95 114 133 152 171 190 Ipm Flow Rate 7.5 15 2.3 4.6 mps bars psi 2"(50mm) Flow Rate v, .8 12 N bars psi 1"(25mm) * W 7 10 w 1.1 16 p - .8 12 .5 8 v .7 10 3 A 6 y .4 6 ,_4) .11 2 a .3 4 a 0 0 ' 1 2 0 25 50 75 100 125 150 175 200 gpm 0 5 10 15 20 25 30 35 40 45 50 55 69 gpm AP 0 95 190 285 380 475 570 665 760 Ipm 'fir 0 19 38 57 76 95 114 133 152 171 190 209 228 Ipm 5 7.5 10 15 fps 5 7.5 10 15 1.5 2.3 3.0 4.6 mps 1.5 2.3 3.0 4.6 fps Flow Rate mps Flow Rate : A I IMPORTANT inquire with governing authorities for local installation requirements. Q M E S ISO 9001 t FKS 'FIRE A Division of Watts Industries www.amesfirewater.com CERTIFIED i 875 National Drive • Suite #107 • Sacramento, CA 95834 • Phone: 916-928-0123 • Fax: 916-928-9333 ES-A-2000B 0313 ©Ames Co.2003 Printed in U.S.A.