Loading...
Report (12) v COr 016 ' ).: } IS_--r 144111.4111% Rx - ${ y# SO w M a w w w M VJ ON w w r w w w w w wWASHINGTON STATE w CERTIFICATE OF COM ETENCY 1 I FIRE PROTECTION SPRINKLER SYSTEMS I 1 1 Williem J. LeFave I 3794-0507-A Level 1 I 1 AGS Construction, L.L.C. I d /_�� f AGSCOCL880M5 /(o cr 1 r" 1 t 1 i 1y31 Signature/ Expires 1 Fire Protection 6y Computer Design w w w'w'�"""'w w w..w..../1 w NW Plumbing Concepts Bill LeFave 5642 SW Idaho St. Portland, OR. 97221 - - 503-293-5451 Job Name : Brittany Homes Building : 1 Location : 6919 Oak St., Tigard, Oregon System : 1 Contract : Data File : 3_1_16_GravityPlumbing_BrittanyHomes_69190akStTigardOregon.W Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 NW Plumbing Concepts Page 1 Brittany Homes Date 3/1/2016 HYDRAULIC CALCULATIONS for Project name: Brittany Homes Location: 6919 Oak St., Tigard, Oregon Drawing no: 1 Date: 3/1/2016 Design Remote area number: 1 Remote area location: NE Corner Bedroom Occupancy classification: 2013 NFPA 13D Standard Density: .05 - Gpm/SqFt Area of application: 262 - SqFt Coverage per sprinkler: 256 - SqFt Type of sprinklers calculated: Senju RC-RES, 4.9 K-Factor No. of sprinklers calculated: 2 In-rack demand: 0 -GPM Hose streams: 0 -GPM Total water required(including hose streams): 26.776 -GPM @ 56.344 - Psi Type of system: Wet Volume of dry or preaction system: 0 - Gal Water supply information Date: 2/1/16 Location: Onsite Per Jon Hinkle the Plumbing Contractor Source: 1"Water meter Name of contractor: Gravity Plumibng Address: Phone number: Name of designer: Bill LeFave Authority having jurisdiction: City of Tigard Oregon Notes: (Include peaking information or gridded systems here.) Plumbing contractor provided elevations, pressures and distances for calculations. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C NW Plumbing Concepts Page 2 Brittany Homes Date 3/1/2016 City Water Supply: Demand: Cl -Static Pressure : 65 D1 - Elevation : 5.197 C2- Residual Pressure: 65 D2 -System Flow : 26.776 C2 -Residual Flow : 50 D2-System Pressure : 56.344 Hose ( Demand) D3 -System Demand : 26.776 Safety Margin : 8.656 150 140 130 P 120 R 110 E 100 S 90 S 80 U 70 Cl C2 O p R 60 D2 E 50 40 30 20 10 ;,,,.,.X11.. ......... . . . . . . . . . . . . . . . . . . . . . , 10 20 30 40 50 60 70 80 90 FLOW( NA1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 m. Fittings Used Summary NW Plumbing Concepts Page 3 Brittany Homes Date 3/1/2016 Fitting Legend Abbrev. Name % 3/a 1 11/4 1% 2 2% 3 3% 4 5 6 8 10 12 14 16 18 20 24 N* CPVC 90'Ell Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 0* CPVC Tee-Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R* CPVC Coupling Tee-Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 Zwa Watts 007 Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a *show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a *will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD • ' NW Prumbing Concepts Page 4 Brittany Homes Date 3/1/2016 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. 1 12.0 4.9 7.0 na 12.96 0.05 1 7.0 2 12.0 4.9 7.95 na 13.81 0.05 1 7.0 3 0.0 26.57 na TOR 0.0 29.75 na BOR 0.0 36.51 na MTR 0.0 51.47 na POS 0.0 56.34 na The maximum velocity is 10.41 and it occurs in the pipe between nodes MTR and POS Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 • Final Calculations - Hazen-Williams NW Plumbing Concepts Page 5 Brittany Homes Date 3/1/2016 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 1 12.96 1.101 2N 14.0 16.000 7.000 K Factor=4.90 to 150.0 R 1.0 15.000 0.0 2 12.96 0.0305 0.0 31.000 0.946 Vel = 4.37 2 13.82 1.101 N 7.0 85.000 7.946 K Factor=4.90 to 150.0 13R 13.0 30.000 5.197 3 26.78 0.1167 20 10.0 115.000 13.425 Vel = 9.02 3 0.0 1.394 N 8.0 60.000 26.568 to 150.0 6R 6.0 26.000 0.0 TOR 26.78 0.0370 20 12.0 8. 6.000 3.181 Vel = 5.63 TOR 0.0 1.394 Zwa 0.0 5.000 29.749 to 150.0 2R 2.0 2.000 6.500 ** Fixed Loss = 6.5 BOR 26.78 0.0370 0.0 7.000 0.259 Vel = 5.63 BOR 0.0 1.263 0.0 200.000 36.508 to 150.0 0.0 0.0 3.000 ** Fixed Loss = 3 MTR 26.78 0.0598 0.0 200.000 11.965 Vel = 6.86 MTR 0.0 1.025 Eql 9.45 20.000 51.473 to 150.0 0.0 9.450 0.0 POS 26.78 0.1654 0.0 29.450 4.871 Vel = 10.41 0.0 26.78 56.344 K Factor= 3.57 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 3/1/2016 8:34:54 AM Section 2 -Raw Data for Brittany Homes DataFile=D:IUserslBill LeFavelDocumentslH Fields Page 1 ydraCalsl3_1_96_GravityPlum bing_BrittanyHomes_69190 Strt Fns Dia akStTigardOregon,WXF Pnt. Pnt. Type Length& Fittings C 1 2 Fact Markang Num K Den Area Press Hds Fact Elev 2 1 CPVC 16 2N1R 3 3 1 CPVC 150 TOR 1.25 CPVC 605 N6R201N13R20 TOR BOR 1.25 150 4.9 .05 1 BOR MTR 1.5 CPVC 51Zwa2R2# 150 4.9 .05 1 7 12 MTR Aquapex 200 3# 150 12 POS POS 1 COPPER-L 20 7 150 150 Page 2 31112016 8:34:54 AM Section 3 Raw Data for Brittany Homes File= (Untitled) Misc Information and Water Supplies Common Elevation Common Elevation=0 Calculation Question Answers Remote Point= 1 Source Point= POS Auto Peak Move Length= 0 Locate Remote seLdngths=Y Auto Alter Fitting Auto Peak=No Alter Lengths After Auto Peak=No City Water Supply Information Connection Point=POS Static Pressure= 65 Residual Pressure= 65 Residual Flow= 50 riLCC,r-IVFD MA1 2016 C Yry OF ft;:: 1 of 8 SIL r SENJU SPRINKLER CO.,LTD. 111111Residential Lead Free Flat Concealed Sprinkler, -- jime Pendent. I�I11A.PLI,„ Model: RC-RES, K-Factor: 4.9, SIN: SS8464 GENERAL DESCRIPTION The Model RC-RES Residential Flat Concealed Sprinklers are automatic sprinklers of the compressed fusible solder type.These are decorative and fast response.The Cover Plate Assembly hides the Deflector, Heat Responsive Element etc.,which is in turn concealed above the ceiling. The cover plate has a flat profile, and its diameter is extremely small (2-5/8 inch, 68mm). The push-on and/or thread-on, thread-off design of the concealed cover plate assembly allows easy installation of the cover plate. Therefore, the Model RC-RES should be your first choice when aesthetics is the major consideration for ultimate appeal and unbeatable performance is desired. The Model RC-RES is designed for the residential occupancies and it is perfect for use in homes, hotels and other living quarters. The Model RC-RES is to be used in wet pipe residential sprinkler systems for One- and Two- Family Dwellings and Manufactured Homes per NFPA 13D; wet pipe residential sprinkler systems for Residential Occupancies up to and Including Four Stories in Height per NFPA 13R;or,wet pipe sprinkler systems for the residential portions of any occupancies per NFPA 13. The Model RC-RES has a 4.9 (70.6 LPM/bar1 ) K-factor that meets the required residential flow rates with minimal residual pressure,which allows for smaller pipe sizes and water supply requirements. For extended installation flexibility, the Model RC-RES provides 1/2 inch (12.8mm) vertical adjustment. This adjustment in installation decreases the need for precise cutting of the pipe that drops to the sprinkler and allows for a perfect fit with a range of pipe lengths. The heat sensitivity and water distribution design of Model RC-RES allows for an increased chance of residents' escape or evacuation in case of fire. However, residential fire sprinkler systems are not a substitute for fire safety awareness or fire safety construction required by building codes. "Lead Free" is defined in the Reduction of Lead in Drinking Water Act(S.3874)endorsed by AWWA's Water Utility Council, and California Assembly Bill #1953 as having less than or equal to a weighted average of 0.25% lead in wetted surface of pipes, plumbing fittings and fixtures. WARNINGS The Model RC-RES must be installed and maintained in accordance with the rules stated herein as well as in compliance with the applicable standards of the National Fire Protection Association regulations and the standards of any other authorities having jurisdiction. In the event of this condition, consult the authorities having jurisdiction for guidance and approval. Failure to do so may impair the integrity of these devices. It is the responsibility of the installing contractor to provide a copy of this document to the owner or his representative, and in turn, it is the obligation of the owner to provide a copy of this document to a succeeding owner. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any related questions. Document No.0085160 Date :Feb/09/2015 a ', Page : 2 of 8 TECHNICAL DATA AeULus , NSF-61-G Sprinklerpprovals:IdentificationListedNumber(SIN):SS8464 2—76'(0 52mm) Maximum Working Pressure: 175psi(12.1 bar) NPT1 2 Markin. Discharge Coefficient(Nominal K-Factor): Lot No.Year of Manufacture K=4.9 GPM/psi112(70.6 LPM/bar112) :311 I I SIN:558464 O _— K—factor:K4.9 Temperature Rating: E ` �� Temperature Rating or 1757TC UL Mark or 175'F/79'C 162°F (72°C)Sprinkler with 140T (60°C)Cover Plate L ri control No.:6P37 175T (79°C)Sprinkler with 162T (72°C)Cover Plate o II IIII NSFRMark NSF-61-G Color Code(Sprinkler) �N © }i I�' � 162T (72°C): Uncolored a 01 Body(Copper Alloy) ��� Deflector(Phosphorus Bronze) 175E (79°C):White }`'ft ©30 Gasket(PTFE) Color Code(Cover Plate) �_�l" �r—�� ®Fusible Metal(Solder) OS Heat Collector(Copper) 140°F (60°C): No Mark 2-5/8"(0 68mm) ©Cover Plate Assembly 162°F (72°C):White-Colored Mark or 3—Y44"(4)83mm) Vertical Adjustment: 1/2 inch(12.8 mm) or 2—%"square(068mm) Cover Plate Finishes: Standard Finishes- FIGURE 1. Model RC-RES K=4.9 White,Ivory, Beige,Brown, Black,Nickel, Wood Grain Color Code .l• Custom Finishes- V SIN-ac or: 4K i" �� K-factor:K4.9 Custom color and custompattern coverplates are �A T162 F/72'C ort175'F/79'C irte,--�`� available on special order. Contact a Senju 4, ' •�,, UL Mark Sprinkler representative with any custom orders. I} 111L-C, o of Please see chart on Page 8 for more detail. Physical Characteristics: Ref.Figure 1 "''�- COVER PLATE SPRINKLER (Top view) (Bottom view) OPERATION FIGURE 1-1. Markinq(Color Code) In case of fire, the solder component that holds together the Cover Plate and the Retainer melts. Then, the Cover Plate is released at once. As a result, the Deflector drops down to the intended position.Two Heat Collectors are exposed to fire, and when sufficient heat from the fire is recorded, internal components of the sprinkler to fall apart.This leads to allow the water flow to be distributed on the affected by fire area. (Ref. Figure 2) // 0/;/ ii n .„ / FloARTII. 11 '1 , --1 ' 71 1M' 1 71-tip 1IICIIs Normal Condition ..► Cover Plate Operation my Sprinkler Operation Water Discharge FIGURE 2. OPERATION PROCESS (The figure is for illustrative purpose only) Document No.0085160 Date :Feb/09/2015 DESIGN CRITERIA Page :3 of 8 The herein stated rules for use and installation of Model RC-RES are provided by the manufacturer and must be strictly implemented for safe and full results. NOTES Residential Fire Sprinkler Systems should only be designed and installed by individuals who are completely familiar with automatic sprinkler system design,installation procedures,and techniques. Several criteria may apply to the installation and usage of each sprinkler. Consequently, it is recommended that the sprinkler system designer review and develop a working understanding of the complete list of criteria prior to initiating the design of the sprinkler system. Questions concerning sprinkler installation and usage criteria, which are not coverage by the following instructions, should be submitted to Contact Company.Include sketches and technical details as appropriate. In some instances, the requirements of this document may concern specifications which are more stringent and which take precedence over those specified in NFPA 13, 13D, 13R, or by the authority having jurisdiction. The Model RC-RES must not be used in applications where the air pressure above the ceiling is greater than that below. Inspect all sprinklers after installation to ensure that both the gap between the cover plate,ceiling and the 6 slots in the cup are open and free from any air flow impediment. The spray from the sprinkler is distributed radically outward and downward from the sprinkler deflector. Consequently, the sprinklers must be located such that there will be no blind spaces shielded from spray by partitions,room dividers, overhangs or other parts of the dwelling structure. The number of sprinklers within each compartment(as defined by NFPA 13, 13D, or 13R) must be kept as small as possible.Do NOT use more sprinklers than necessary to cover a particular space. Use only the Cover Plate provided with the Model RC-RES. The sprinkler must be secured in place by firmly fastening the sprinkler system piping to the structure. If the sprinkler is not properly secured in position, reaction forces resulting from sprinkler operation could alter its orientation and its water distribution pattern. Obstruction to Water Distribution Locations of sprinklers must follow the obstruction rules of NFPA 13 for Residential Sprinklers. General Service Conditions The Model RC-RES must only be utilized in WET PIPE sprinkler systems. Heat Source Criteria Refer to NFPA 13D or 13R for the requirements relating to the prevention of possible activation of the Heat Responsive Element of Model RC-RES, due to exposure to a heat sources other than an actual fire. Precautionary Warnings for Corrosive Environments The Model RC-RES should not be installed where they may be subjected to a corrosive environment including the following: (1) Chlorine ion and Chloride environment. Stress corrosion cracking may be caused by exposure to environments with Chlorine ion and Chloride. Exposure to this environment may result in sprinklers operating under Non-Fire conditions or Not Operating when exposed to an actual fire. (2) Sprinkler system piping with Copper. Sprinkler systems should be constructed in compliance with the applicable standards and the requirements for the copper piping when copper piping is used in the sprinkler system. (Reference standards NFPA 13, ASTM B813, B828, and CDA (Copper Development Association)—Solder Joint) All residual flux must be removed from the interior and exterior of copper piping by thoroughly flushing before installation of the Sprinkler Heads. Otherwise, residues of flux may cause corrosion and leakage in the sprinkler system. Hydraulic Design Criteria The minimum required sprinkler flow rates for system designed to NFPA 13D or 13R are given in Table A as a function of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from the most hydraulically demanding sprinkler from each of the total number of"design sprinklers"as specified in NFPA 13D or 13R. For systems designed to NFPA 13, the number of designed sprinklers is to be the four most hydraulically demanding sprinklers.The minimum required discharge from each of the four sprinklers is to be the greater of the followings; • The flow rates given in Table A for NFPA 13D and 13R as a function of temperature rating and maximum allowable coverage area. Document No.0085160 Date :Feb/09/2015 Page : 4 of 8 • A minimum discharge 0.1GPM/sq.ft. [4.07LPM/sq.m] over the "design area" comprised of the four most hydraulically demanding sprinklers for the actual coverage areas being protected by the four sprinklers. TABLE A. NFPA 13D& 13R WET PIPE HYDRAULIC DESIGN CRITERIA for Model SS8464 Ordinary Intermediate Maximum Maximum Temperature Rating Temperature Rating Deflector Minimum Coverage Spacing 162°F (72°C) 175"F (79°C) to Installation Spacing Area Ft. Flow(b) Pressure ) Flow(b) Pressure') Type Ft. Ft. x Ft. Ceiling (m) (m xm) (m) GPM PSI GPM PSI (LPM) (bar) (LPM) (bar) Smooth 12x12 12 13 7.0 13 7.0 Ceilings (3.7x3.7) (3.7) (49.2) (0.48) (49.2) (0.48) 3/8 to 7/8 Inches. 14x14 14 13 7.0 13 7.0 Beamed (4.3x4.3) (4.3) (49.2) (0.48) (49.2) (0.48) Ceilings per NFPA 16x16 16 13 7.0 14 8.2 13D,13R 13R Concealed (2.4) ( .9x4.9) (4.9) (49.2) (0.48) (53.0) (0.57) or Installed in beam 18x18 18 17 12.0 18 13.5 3/8 to (5.5x5.5) (5.5) (64.3) (0.83) (68.1) (0.93) 7/8 inches below 20x20 20 21 18.4 — — bottom of (6.1x6.1) (6.1) (79.5) (1.27) beam. (a) For coverage area dimensions less than the above mentioned, it needs to use the minimum required flow for the Next Higher Coverage Area listed. (b) Requirement is based on minimum flow in GPM/LPM from each sprinkler.The associated residual pressures are calculated using the nominal K-Factor. Refer to Hydraulic Design Criteria Section for details. (c) For systems with ceiling types smooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R or 13 as applicable. Sprinkler Spacing Criteria The minimum spacing between sprinklers is 8 feet(2.4m). The maximum spacing between sprinklers cannot go beyond the coverage area calculated by using the specific hydraulic factors. (Ref.Table A) INSTALLATION The Model RC-RES must be installed in accordance with the following instructions. NOTES Do not use any sprinklers which have been subjected to potential mechanical damage.Do not use any sprinklers which show deformation or cracking in either the Sprinkler or the Protective Cap. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. The Protective Cap must remain on the sprinkler during installation and until the ceiling installation is completed. The Protective Cap must be removed to place the sprinkler in service. Document No.U085160 Date :Feb/09/2015 Page : 5 of 8 Use a torque of 7 to 14 ft.lbs(9.5 to 19.0Nm)to achieve a 1/2 inch NPT sprinkler joint.If you exceed the recommended maximum torque, this could result in damage to the sprinkler inlet, which may lead to leakage from the sprinkler. In case of insufficient adjustment in Cover Plate installation,do not try to overly tighten,screw the sprinkler too loosely or make any modification to the cover plate assembly.Readjust the sprinkler fitting for a better fit. Installing Procedure Step 1 The installation requirements for the sprinkler are as follows: to be installed only in the pendent position with the waterway perpendicular to the ceiling. Install the sprinkler fitting so that the distance from the face of the fitting to the mounting surface will be nominally 2 inch(50.8mm)as shown in Figure 3. Step 2 With pipe thread sealant applied to the threads, hand tighten the sprinkler into the sprinkler fitting. Then tighten it with the Sprinkler Socket or Wrench & Socket Combination (Ref. Figure 4). The grooves of the Socket must fit perfectly with the grooves on the Sprinkler for proper installation(Ref. Figure 4). Step 3 If desired the Protective Cap may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Protective Cap. Before the installation of the ceiling,the sprinkler installation can be started with the 2-3/8 inch (60mm) diameter clearance hole (Ref. Figure 3). Use the "Tolerance Limit of Ceiling Level" indicator on the Protective Cap to check for proper installation height(Ref. Figure 3). Make a Space Here Do T UN Ave. "'(6.4mm) Over—Tighten hten /a —Ti Min.Y"(3.2mm) g Groove on the S.rinkler I I _ ow/ NITWIT"* iii mais Ei E Tolerance Limit E of Ceilin. Level Protective Ca. o � N � N t iCeiling��=� =Ir 7 y I,I • ' • Mounting Surface Groove of the Socket Mountin. Surface 2-3A" 0;560mm) Socket Wrench Ceiling Hole Diameter CORRECT INCORRECT -I FIGURE 3. INSTALLATION FIGURE 4 Step 4 Use the Cap Remover RC to remove the Protective Cap(Ref. Figure 5), and then push or screw a Cover Plate Assembly on the Cup of the Sprinkler by hand until its flange just comes in contact with the ceiling (Ref. Figure 6 and Figure 7). Stop tightening the Cover Plate Assembly once the flange has come in contact with the ceiling. If the ceiling has been lifted from its normal position in the process of tightening of the Cover Plate Assembly, readjust the cover plate assembly as necessary. If the flange of the Cover Plate Assembly cannot come in contact with the ceiling sufficiently, readjust the sprinkler fitting as necessary. When properly installed, there is a nominal 1/16 inch (1.6mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 6 Document No.0085160 Date :Feb/09/2015 1 ,. Page : 6 of 8 IIII .111 MI Il Ii i Sprinkler Head � '=�� ce_ i_ kmaij MINIM Protective Cap Bra: onimio Step 1 ■ ...... ,.... Ca. Remover RC illil Step 24 .......■ ■ Hook by turning 11 Step 3 4 Pull down FIGURE 5. PROTECTIVE CAP REMOVAL MO MO VIII lISTS ISIS cu. KIM mom mom iii ii -LAIL. A.., i— IN -L' ir- .111 .-ii r — _ N E®3Mr EE ■ N Ceiling //�` - \Ceiling Ceiling�-- Ceiling7 „/I —� Mounting Surface — Screw E Deflector ,�v 4-.1 +co u s Cover Plate Assembly L2-5/e"(068mm) or 3—Y4"(083mm) or 2-5/B-square(068mm) FIGURE 6 —\---�� MO INKS \ / Il�A � - E u imp LvT _i l LI �v J �____-_ NI N • jCeiling</ /Ceiling,<�— _ /Ceiling —J - --- _. a -- i INCORRECT CORRECT INCORRECT FIGURE 7. INSTALLATION(CORRECT OR INCORRECT) Document No.U085160 Date :Feb/09/2015 Page : 7 of 8 CARE AND MAINTENANCE The following instructions must be implemented for the maintenance and service of the Model RC-RES. NOTES Wet pipe sprinkler systems must be maintained at a minimum temperature of 40 F/4°C to prevent freezing and bursting of the pipe and/or sprinklers. Automatic sprinklers are not to be tested with a heat source. Operation of the heat responsive element can result. Absence of a Cover Plate Assembly may delay the response time of the sprinkler in case of fire. Install the cover plate assembly properly, as shown in Figure 6. Improper installation of the cover plate assembly may cause improper operation or non-operation. If the ceiling is to be repainted after the installation of the Sprinkler,care must be exercised to ensure that the new paint does not seal off any of the air gap. Factory painted Cover Plates must not be repainted. They should be replaced, if necessary, by factory painted cover plates.Non-factory applied paint may adversely delay or prevent sprinkler operation in case of a fire. Do not pull the Cover Plate. Separation may result. In preparation for maintenance of the fire protection system, permission to close the main control valve must be obtained from the proper authorities and all affected by this action parties must be informed before the maintenance session can commence. Do NOT enclose any sprinklers within drapes, curtains,or valances. Do NOT hang anything from the sprinklers. Do NOT clean the sprinklers with soap and water, detergents, ammonia, cleaning fluids, or other chemicals. Remove dust, lint, cobwebs, cocoons, insects, and larvae by gently brushing with a feather duster or gently vacuuming with a soft bristle(Le.,dusting)brush attachment. Exercise suitable safety precautions in the use and storage of highly flammable materials. The rapid rate of fire development and spread of these materials can reduce the ability of the sprinkler systems to aid in the control of a fire involving such hazards. Leaking or corroded sprinklers must be replaced. Automatic Sprinklers must never be shipped or stored where the temperature exceeds 100°F/38°C. Automatic sprinkler must never be physically altered, such as painted, plated, or coated, once shipped from the factory. If the sprinklers have been in any way modified,they must be replaced. Great caution must be applied to prevent damage to the sprinklers at all stages-before, during, and after installation. Damaged units, as a result of dropping, hitting,over-tightening, or wrench slippage, must be replaced. The Model RC-RES must only be replaced with pendent sprinklers which are listed for residential fire protection service and which have the same nominal K-Factor,the same coverage area,and the same or lower flow ratings(as indicated under Table A "Hydraulic Design Criteria"). When remodeling, such as by adding false beams or light fixtures or changing the location of compartment walls, first verity that the new construction will not violate the installation requirements of the applicable standards of NFPA.Alter the new construction and/or the sprinkler system to suit the requirements of this document and the applicable NFPA regulations. The owner is responsible for the maintenance of the sprinkler system, including inspection and testing, its compliance with this documents, as well as the standards of the National Fire Protection Association(e.g., NFPA 25),and the regulations of any other authorities having jurisdiction.The owner should direct any questions regarding the above rules and regulations to the installing contractors or the sprinkler manufacturer. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with NFPA 25. Document No.0085160 Date :Feb/09/2015 Page : 8 of 8 ORDER PROCEDURE When placing an order,please contact a local distributor with the following information(Model Name,Specify,Temp.and Finish). Sprinkler: Model: RC-RES (SIN: SS8464, Residential Flat Concealed Sprinkler, Pendent, K4.9,Temperature: 162°F (72°C)or 175°F (79°C)) Cover Plate Assembly: 2-5/8 inch(t 68mm)or 3-1/4 inch (083mm)or 2-5/8 inch square(068mm), Order Separately from Sprinkler Please refer to the chart below for available sizes,temperature, and finishes. Standard Finishes Custom Finishes White Ivory Beige Brown Black Nickel Wood grain Custom Color Custom Pattern 2-5/8"Round, 140°F 0 0 - - - 0 - 0 0 3-1/4"Round, 140°F 0 0 0 0 0 0 0 0 0 2-5/8"Square, 140°F 0 - - - - - - 0 0 2-5/8"Round, 162°F 0 - - - - - - 0 0 3-1/4"Round, 162°F 0 - - - - - - 0 0 Tools for Installation of Model: RC-RES • Socket for Model RC-RES • Wrench&Socket for Model RC-RES • Cap Remover RC Document No.0085160 Date :Feb/09/2015 .,, porni RD 13 a The Symbol of Protection Residential Riser Features • Pre-assembled and pressure tested f 4.1',» • Available in I",1 1/4",1 1/2",&2"nominal pipe size models • Female adapter ships loose so riser can be installed in a confined space • Fits in standard 2X4 construction walls , ,:z. . ...,- ..,. iy • Installation must be performed by qualified personnel and in w M.. accordance with all national and local codes and ordinances. • Shock hazard.Disconnect power source before servicing.Serious injury or death could result. • Risk of explosion.Not for use in hazardous locations.Serious injury or death could result. Description Flow Switch Technical Specifications The RDI3 Riser (with NPT connectors) is constructed from Listed CPVC products suitable for fire sprinkler services subject to the Dimensions See Fig 2 limitations and installation requirements of Flameguard®CPVC pipe Service Pressure 175 PSI(12,07 BAR)-UL and Spears®CPVC.fittings.The RD 13 Riser incorporates a VSR-SG Flow Sensitivity flow switch,gauge,and drain/test valve. The VSR-SG flow switch is 4-IOGPM(IS-38LP1V1)-LIL equipped with union connection to facilitate the installation and removal Range for Signal of the switch in confined spaces. Maximum Surge 1 H FPS(5.5 m/s) Installation Two sets of SPDT(Form C) 1. Usingappropriate sealant, thread the female adapter on to the 10.0 Amps at l 25'250VAC p Contact Ratings main water supply. Then glue the riser assembly to the female 2.0 Amps at stave Resistive 10 mAinps ruin. at adapter.Pipe the drain connection to an adequate drain location 24VDC Resistive capable of handling the drain discharge.The riser can be mounted 10 in Amps min.at 24VDC in the horizontal or vertical position.Direction of flow is indicated Environmental in Fig. 1. The waterflow switch must be located on the top or Limitations Temperature range:40°F-120°F(4.5°C-49°C)-UL on the side of the pipe when installed in the horizontal position. Conduit This will prevent debris from entering the throat of the waterflow Entrances Two knockouts provided for 1/2"conduit switch which could interfere with proper operation. 2. Following CPVC manufacturer's instructions for preparation and Listing UL,CUL CSFM Listed,and CE Marked gluing of CPVC piping systems,glue the main riser to the main Specifications subject to change without notice supply line for the sprinkler heads.NOTE:All glued connections must be completed and cured before the flowswitch is installed. Service Use (Conti,‘,,,„„,,,,,,,,,,,,....„nued on page 2). Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D ,. . : , .0 ,,,,,,,,,, ,,,,, .11..„ ,„ ,,, , , ; Residential occupancy up to four stories NFPA-13R l •l preNational Fire Alarm Code NEPA-72 t' British Standard BS9251 Do not over-tighten the union nut,hand tighten only.Use of a wrench may cause damage to the union nut. Potter Electric Signal Company, LLC • St.Louis,MO • Tech Support: 866-956-0988/Customer Service: 866-572-3005 • wwwpottersignal.com 5401152-REV K • 2/15 PAGE I OF 3 P n POTTER RD'I 3 The Symbol of Protection Residential Riser Installation (Continued) 3. A thread sealant shall be used in making threaded connections. Teflon®thread tape is the recommended sealant. Some thread sealants other than Teflon thread tape contain solvents or other materials that may be damaging to CPVC.For other types of thread sealants,which have been specifically investigated and confirmed to be"System Compatible",refer to www.spearsmfg.com.Attach gauge to riser.Apply Teflon®tape to male fitting of gauge only.See Fig 1. 4. Check to make sure the proper paddle is installed on the switch. (Paddle size must match the riser pipe size and Tee manufacture.) 5. Install the flow switch to the RD13 Riser.Verify that the o-ring is properly positioned in its groove.Hand tighten the nut to the union after orienting the flow switch in the appropriate direction to detect waterfiow.The paddle must not rub the inside of the Tee or bind in any way.The stem should move freely when operated by hand.See Fig. I. NOTE:Do not leave switch cover off for an extended period of time. 6. The side of flow switch must be perpendicular with the riser piping.See Fig.3. Testing The frequency of inspection and testing for the Model VSR-SG and its associated protective monitoring system,should be in accordance with applicable Codes and Standards and/or the authority having jurisdiction(manufacturer recommends quarterly or more frequently.) If provided,the inspector's test valve(usually located at the end of the most remote branch line)should be used for test purposes.If there is no remote inspection test connection; a short length of hose may be connected to the discharge of the 1"drain line valve,or if the drain line is connected to a drain such as a slop sink or storm drain that will sufficiently handle the discharge of the main drain valve.The drain valve can be used to test the operation of the VSR-SG switch. A minimum flow of 10 GPM(38 LPM)is required to activate this switch.An orifice equal to the smallest sprinkler head orifice used in the system shall be attached to the drain line for testing purposes. Maintenance The VSR-SG waterfiow switch should provide years of trouble-free service. The retard and switch assembly are easily field replaceable. In the unlikely event that either component does not perform properly,please order replacement retard switch assembly stock number 1029030.There is no maintenance required,only periodic testing and inspection.. Removal • To prevent accidental water damage,all control valves should be shut tight and the system completely drained before waterflow detectors are removed or replaced. • Turn off electrical power to the detector,then disconnect wiring. • Loosen nut on union fitting. • Lift detector clear of pipe. Fig 7 Optional Cover Tamper Retard Adjustment Switch The delay can be adjusted by rotating the retard adjustment knob from 0 to the max setting(60-90 seconds). The time delay should be set at the �J� DO NOT LEAVE iJ' minimum required to prevent false alarms. Retard ► �1 '\,:� COVER OFF Adjusting NW's FOR EXTENDED Knob � �r 1r 110 PERIOD OF TIME. (60 r 1 'd 'I Mount so arrow DIRECTION OF J %� on base points WATERFLOW indirection of' t waterfiow J 0 1"Male LT...), DWG, #1063-3 Fitting on --- All Sizes Important: Riser may ` The paddles have raised lettering that show the pipe size and the TEE be 1",for manufacturer they are to he used with. The proper paddle must he used. 1 L/2",or 2" The paddle must be properly attached and the screw that holds the paddle must be securely tightened. Potter Electric Signal Company,LLC • St.Louis,MO • Tech Support: 866-956-0988/Customer Service: 866-572-3005 • www.pottersignal.coin 5401152-REV K • 2/15 PAGE 2OF3 POTTER RD1 3 The Symbol of Protection Residential Riser Dimensions (See Chart Below) Orientation Fig 2 Fig 3 E F F . _ 3 1/2"Gauge (Shipped Loose) M . ACso 11► A B C DITIIIIIII .o, - M�� -II■••E Drain T I�_o IrClIM / _ •o Valve -il�� 1�1 � II NI ApiLim, 0' 1114 4 VSR-SG Flow Switch NPT Adaptor(Shipped Loose) Flow switch must be properly orientated.Side of cover must be perpendicular with the pipe.Improper orientation could delay or prevent notification of waterflow. *RD13 Risers(ASSEMBLED DIMENSIONS) Riser Model Dimension"A" Dimension"B" Dimension"C" Dimension"D" Dimension"E" Dimension"F" Part Number Size Number (in) (mm.) (in.) (mm.) (in.) (mm.) (in.) (mm.) (in.) (mm.) (in.) (mm) 1" RD13-100-1 1119067 16 406 15 3.4 400 14 7/8 378 14 5/8 371 12 1/4 311 10 1/2 267 1 1/4" RD13-125-1 1119077 165/8 422 161/2 419 151/2 394 153/8 391 121/2 318 105/8 270 1 1;2" RD13-150-1 1119087 N/A N/A 16 3/4 425 N/A N/A 15 5/8 397 12 3/4 324 10 3/4 273 2" RD13-200-1 1119097 N/A N/A 18 1/4 464 N/A N/A 16 7/8 429 13 3/8 340 11 1/8 283 Ordering Information Ordering Information Nominal Pipe Model Part Number Site Optional: Cover Tamper Switch Kit,stock no.0090148 1" RDI3 Riser 1119067 Replaceable Components:Retard/SwitchAssembly,stock no. 1029030 1 1/4" RDI3 Riser 1119077 Gauge,Flow Switch,and NPT Adapter shipped loose in box. 1 1/2" RD 13 Riser 1119087 2" RD13 Riser 1119097 Potter Electric Signal Company,LLC • St. Louis,MO • Tech Support: 866-956-0988/Customer Service: 866-572-3005 • www.pottersignal.com 160 8001:20001 DESIGNING,MANUFACTURING, CERTIFIED &DISTRIBUTING QUALITY SYSTEMS 5401152-REV K • 2/15 PAGE 3 OF 3 4, ES-LF007 For Non-Health Hazard Applications Job Name Contractor Job Location Approval Engineer Contractor's P.O. No. Approval Representative LEAD FREE* Series LF007 Double Check Valve Assemblies Sizes: 1/2" -3" (15-80mm) 4Ig 44' Series LF007 Double Check Valve Assemblies shall be installed at ` referenced cross-connections to prevent the backflow of polluted § ` water into the potable water supply. Only those cross-connections identified by local inspection authorities as non-health hazard shall be allowed the use of an approved double check valve assembly. The LF007 features Lead Free*construction to comply with Lead 3/a"(20mm)LF007M3QT Free*installation requirements. Check with local authority having jurisdiction regarding vertical orien- tation,frequency of testing or other installation requirements. The valve shall meet the requirements of ASSE Std. 1015 and AWWA Std.C510.Approved by the Foundation for Cross- t Connection Control and Hydraulic Research at the University T mks of Southern California. �MOS :<•;;7;".?, Features • Ease of maintenance— only one cover •Top entry "" r • Replaceable seats and seat discs • Modular construction II r y •Compact design • Lead Free*cast copper silicon alloy body construction — -2"(15-50rnrn) • Fused epoxy coated cast iron body --- 21/2"-3" (65--80mm) First Check Second Check •Top mounted Lead Free"ball valve test cocks Module Assembly Module Assembly • Low pressure drop The LF007 Series features a modular design concept which facilitates • No special tools required for servicing complete maintenance and assembly by retaining the spring load. •1/2"-1"(15-25mm)have tee handles Specifications A Double Check Valve Assembly shall be installed at each noted location.The assembly shall consist of two positive seating check modules with captured springs and rubber seat discs.The check module seats and seat discs shall be replaceable. Service of NOW'14Vallabe all internal components shall be through a single access cover secured with stainless steel bolts.The Double Check Valve WattsBox Insulated Enclosures. Assemblies shall be constructed using Lead Free*cast copper For more information,send for literature ES-WB, silicon alloy. Lead Free*Double Check Valve Assemblies shall comply with state codes and standards,where applicable, requir- ing reduced lead content.The assembly shall also include two NOTICE resilient seated isolation valves;four top mounted, resilient seated Inquire with governing authorities for local installation requirements test cocks.The assembly shall meet the requirements of ASSE Std. 1015 and AWWA Std.C510.Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University *The wetted surface of this product contacted by consumable of Southern California.Assembly shall be a Watts Series LF007. water contains less than 0.25%of lead by weight. Watts product specificationss in U.S.customary units and mh are eior te and are uct provided for,referencenstronly.For pati ns measurements, WA� ��11' ® please contact Watts Technical Service.Watts reserves the right to change or modify product design,construction,specifications,or materials with- out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold. Pressure — Temperature Models 1/2"-2" (15-50mm) Sizes: Temperature Range: 33°F-180°F(0.5°C-82°C). 1/2"-2" (15-5Omm) Maximum Working Pressure: 175psi(12.1 bar). Suffix: 21/2"-3" (65-8Omm) S-copper silicon alloy strainer Temperature Range: 33°F-110°F(0.5°C-43°C)continuous, LF-without shutoff valves 140°F(60°C)intermittent. Prefix: Maximum Working Pressure: 1 75psi(12.1 bar). U-Union connections Standards 21/2"-3" (65-8Omm) ASSE Std. 1015,AWWA Std.C51O Suffix: IAPMO PS31,CSA 864.5 NRS-non-rising stem resilient seated gate valves oys FjFo ( OSY-UL/FM outside stem and yoke resilient seated gate valves Approvals .NSF LF-without shutoff valves t ASSE,AWWA, IAPMO,CSA,UPC ` U0 l QT-FDA-FDA epoxy coated quarter-turn ball valves • Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California. • Models with suffix LF and S are not listed. • UL Classified(without shutoff valves only)3/4"-2" (20-50mm)(except O07M3LF) • UL Classified with OSY gate valves (21/2"and 3"horizontal only.) T lig"-2"models Lead Free*with strainer Horizontal and vertical"flow up"approval on all sizes Asa A1 x ........ _____ ... € it • ,^ ' fi ; aimeta 4 "Pi�rr�s�rrrrEr `a _ f ,• snrwrMM 1�' r"-1r) �1i Mgr D �` /sal € .... :77,,,::.,,,,'''T.,.. ,__ Subscript'S'=strainer model Dimensions-Weights MODEL SIZE(ON) DIMENSIONS WEIGHT A B C D F G R T in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. tAT LF007QT 1/2 15 10 254 45/6 117 27/6 62 — — 5 127 3% 85 2%6 59 21/6 52 4.5 2 tAT LF007M3QT 3/4 20 111/6 282 4 102 31 79 — — 6%6 157 37/6 87 2% 54 15/6 33 , 5 2.3 tAT LF007M1QT 1 25 131/4 337 51/s 130 4 102 — — 71 191 33/s 85 11%6 43 11%6 43 . 12 5.4 tAT LF007M2QT 11/4 32 16% 416 5 127 3%6 84 — — 91/2 241 5 127 3 76 2 50 15 6.8 tAT LF007M2QT 11/ 40 16% 425 47/3 124 31/2 89 — — 93/4 248 513/6 148 31/4 79 2"/e 68 15.9 7.2 tAT LF007M1QT 2 50 191 495 61/4 159 4 102 — — 13% 340 61 156 37/6 87 2i1/6 68 25.7 11.7 •T LF0070T-S 1/2 15 13 330 6 152 27/6 62 3 76 5 127 33/s 85 2%6 59 21/6 52 5.5 2.5 •T LF007M3QT-S 3/Ci 20 141 368 61/6 156 31/2 79 3 76 63/is 157 3%6 87 21/8 54 1546 33 6.7 3.1 •T LF007M1QT-S 1 25 171%6 157 7%4 197 4 102 31/4 83 71/ 191 3% 85 111/6 43 111A6 43 14 6.4 •T LF007M2QT-S 11/4 32 211 546 71A6 179 3%6 84 312 83 91/2 241 5 127 3 76 2 50 19 8.6 •T LF007M2QT-S 11/2 40 25%6 637 71A6 179 31/2 89 33/4 95 9% 248 513/6 148 31/2 79 211/6 68 19.6 8.9 •T LF007M1QT-S 2 50 271/4 692 83/4 222 4 102 4 102 13% 340 6'/6 156 3%6 87 211/6 68 33.5 15.2 Dimensions—Weights Sizes:21/2"-3"(65-80mm) amommowo �,_ __ _ (open) — !I 9"(229inin) -., — R te. tR. , { 'NV " airr r�r fl i r..._ Ait 6 .,..,0 7—„,,... 45/6'(109mm) 0 0 I UI ._,— ; M R M _... A MODEL SIZE{DN) DIMENSIONS WEIGHT Strainer Dimensions A B E,E1 R SIZE WEIGHT in. mm i in. mm in. mm in. mm in. mm lbs. kgs. M N • LF007QT-FDA 2'/2 65 33V6 ! 841 63/8 162 9'/6 230 83/4 222 155 70 in. mm in. mm in. mm lbs. . kgs. A LF007-NRS 21/2 i 65 331/8 841 93/8 238 9'/8 230 83/4 222 155 70 21/2 65 10 254 61/2 165_._._._28_-.x___.13 ip A• LF007-0SY 2'/2 65 331/8 841 163/8 416 91/8 230 83/4 222 158 72 3 80 10'/8 267 7 178 34 j 15 LF007-QT-FDA 3 80 331/8 867 63/8 162 91/8 230 83/4 222 155 70 A LF007-NRS 3 80 331/g 867 101/4 260 9'/8 230 83/4 222 185 84 ♦♦ LF007-0SY 3 80 331/8 j 867 187/8 479 91/s 230 83/4 222 185 84 1"LFU007M1QT Union Tailpiece Union Tailpiece Union Nut ------ Union Nut .. i* [ it Iiiii E , J , ' 181r 111 A Sizes:1/2"-2”(15-50mm) MODEL SIZE(DN) DIMENSIONS A in. mm in. mm LF00070T 1/2 15 1213/6 326 LF0007M20T 3/4 20 1313/48 350 LF0007M20T _ 1 25 165/8 422 LF0007M2OT 11/4 32 203/4 527 LF0007M2QT 11/240 211/2 546 LF0007M1QT 2 50 241/2 622 Capacity As compiled from documented Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California lab tests. if Typical maximum system flow rate(7.5 feet/sec.,2.3 meters/sec.) **UL rated flow • 1%2"(15mm) 1Y (40mm) bars psi tt bars psi tt .8 12 p,.8 12 2 .7 10 Q .7 10 ' t= .5 8 In... � .5 8 y• .3 4 H .3 4 .1 2 2 .1 2 o- 0 0 ° 0 0 0 2 4 6 8 10 12 gpm 0 10 20 30 40 50 60 70 80 90 100 110 120 gpm 0 7.6 15.2 22.8 30.4 38 45.6 Ipm 0 38 76 114 152 190 228 66 304 342 380 418 456 ipm 5 7.5 10 fps 5 7.5 10 15 fps 1.5 2.5 3.0 mps 1.5 2.5 3.0 4.5 mps Flow Flow bars psi 3/4"(20mm) tt 2"(50mm) 1.5 22 bars psi tt .8 12 1.2 18 • - - G..7 10 ' o .96 14 _ .5 8 ....r.•'�` ` 4 6 C m 3 4 • s9 10 y.1 2 y• .41 6 6 0 0 .�..�"� 0 25 50 75 100 125 150 175 200 gpm a - 0 95 190 285 380 475 570 665 760 Ipm .14 2 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps 0 5 10 15 20 25 30 35 40 45 50 gpm 0 19 38 57 76 95 114 133 152 171 190 Ipm Flow 7.5 15 Ips 2.3 4.6 mps Flow 1"(25mm) 21/2"(65mm) bars psi bars psi 0181 162 tt o.7 10 tt -A- m .7 10 a.5 8 • _• .5 8 y.4 6 • vs 2 .3 4 ,.++••r-' 2.1 2 0_ .1 2 • 0 0 0 5 10 15 20 25 30 35 40 45 50 55 60 gpm 0 25 50 75 100 125 150 175 200 225 250 gpm 0 19 38 57 76 95 114 133 152 171 190 209 228 Ipm 0 95 190 285 380 475 570 665 760 855 950 Ipm 5 7.5 10 15 fps 5 7.5 10 15 fps 1.5 2,3 3.0 4.6 mps 1.5 2.3 3.0 4.6 mps Flow Flow 11/4"(32mm) 3"(80mm) bars psi tt bars psi 1 14 .7 10 tt - o •8 12ea 5 8 O .7 10 / 2 4 6 .a...-........+ . ..+• 5 .5 8 Mme/ Ct "/' o `.3 A 0.0 d .1 2 i 0 0 0. 0 25 50 75 100 125 150 175 200 225 250 275 300 325 gpm 0 0 0 95 190 285 380 475 570 665 760 855 950 1045 1140 1235 ipm 0 10 20 30 40 50 60 70 80 90 100 110 120 gpm 5 7.5 10 fps 0 38 76 114 152 190 228 266 304 342 380 418 456 1pm 1.5 2.3 3.0 mps 5 7.5 10 15 fps Flow 1.5 2.3 3.0 4.6 mps Flow • BUILD/rye e wwAl-rs® M9001-2008: MgM",A CERTIFIED A Watts Water Technologies Company USA:Tel:(978)688-1811 •Fax:(978)794-1848•www.watts.corn Canada:Tel:(905)332-4090•Fax:(905)332-7068•www.watts.ca ES-LF007 1 325 ©2013 Watts tqco I & Building Products rapid response"" HOME FIRE SPRINKLER SYSTEM Technical Services:Tel: (800)381-9312/Fax: (800)791-5500 BlazeMaster® CPVC Fire Sprinkler Pipe & Fittings Submittal Sheet General Description Technical Tyco® CPVC Pipe and Fittings pro- Data duced by Tyco Fire & Building Prod- ucts (TFBP) are designed exclusively Sizes • , � � for use in wet pipe automatic fire sprin- 3/4"to 3" kler systems. The Tyco CPVC Pipe Maximum Working Pressure and Fittings are produced from Blaze- 175 psi • Master® CPVC compound that is a p specially developed thermoplastic Approvals a compound composed of post chlorin- UL, FM, C-UL, NSF, LPCB, MEA, and ated polyvinyl chloride (CPVC) resin the City of Los Angeles. (Refer to (n- and state of the art additives. Tyco stallation Handbook IH-1900 dated CPVC Pipe and Fittings are easier to June 2008 for exact listing/approvalf • install than traditional steel pipe sys- information.) tems, and at the same time, provide Manufacture Source superior heat resistance and strength U.S.A. as compared to traditional CPVC and PVC piping materials used in the Material plumbing trade. Various adapters are • Pipe:ASTM F442, SDR 13.5 available to connect CPVC pipe to me- tallic piping. All female pipe thread • Fittings: ASTM F438 (Sch. 40) and adapters have brass inserts for dura- ASTM F439(Sch. 80),ASTM F1970 bility. Grooved adapters connect di- Color rectly to grooved end valves and me- Orange tallic pipe, with flexible grooved end couplings. NOTICE Tycoe CPVC Pipe and Fittings pro- duced with BlazeMastere CPVC com- pound described herein must be in- stalled and maintained in compliance with this document and with the appli- cable standards of the National Fire Protection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may im- pair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. BlazeMastere is a registered trademark of The Lubrizol Corporation Page 1 of 2 JUNE, 2008 TFP1915 Page 2 of 2 TFP1915 Installation Limited Tyco® CPVC Pipe and Fittings pro- Warranty duced by Tyco Fire & Building Prod- ucts (TFBP) are to be installed in Products manufactured by Tyco Fire& accordance with Installation Hand- Building Products (TFBP) are war- book IH-1900 dated June 2008. ranted solely to the original Buyer for ten(10)years against defects in mate- Care and rial and workmanship when paid for and properly installed and maintained under normal use and service. This Maintenance warranty will expire ten (10) years for the in- from date of shipment by TFBP. No The owner is responsible warranty is given for products or com- spection, testing, and maintenance of ponents manufactured by companies their fire protection system and de- not affiliated by ownership with TFBP vices in compliance with this docu- or for products and components which ment, as well as with the applicable have been subject to misuse,improper standards of the National Fire Protec- installation, corrosion, or which have tion Association (e.g., NFPA 25), in not been installed, maintained, modi- addition to the standards of any fied or repaired in accordance with ap- authority having jurisdiction. The in- plicable Standards of the National Fire stalling contractor or product manufac- Protection Association, and/or the turer should be contacted relative to standards of any other Authorities any questions. Having Jurisdiction. Materials found Automatic sprinkler systems should be by TFBP to be defective shall be either inspected,tested,and maintained by a repaired or replaced, at TFBP's sole qualified Inspection Service in accord- option. TFBP neither assumes, nor ance with local requirements and/or authorizes any person to assume for it, national codes. any other obligation in connection with the sale of products or parts of prod- ucts.NOTICE TFBP shall not be responsible for sprinkler system design errors or sup- Beforeinac- closing a fire protection system curate or incomplete information control valve for inspection or mainte- plied by Buyer or Buyer's repre- control work on the fire protection sys- tem that it controls,permission to shut In no event shall TFBP be liable, in down the affected fire protection sys- contract, tort, strict liability or under tem must first be obtained from the any other legal theory, for incidental, proper authorities and all personnel indirect,special or consequential dam- who may be affected by this action ages, including but not limited to labor must be notified. charges, regardless of whether TFBP was informed about the possibility of After placing a fire protection system such damages, and in no event shall in service, notify the proper authorities TFBP's liability exceed an amount and advise those responsible for moni- equal to the sales price. toring proprietary and/or central sta- The foregoing warranty is made in lieu tion alarms. of any and all other warranties ex- press or implied. including warranties of merchantability and fitness for a par- ticular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law.The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. ©2008 TYCO FIRE&BUILDING PRODUCTS,451 North Cannon Avenue,Lansdale,Pennsylvania 19446 t m prod __ ° CPVC PIPE FIXING SO • Two-hole strap for CPVC pipe • Support CPVC pipe off of the vertical face of structural or composite wood joists with a minimum of 3/8" web thickness • See page 87 ( 1) CADDY, 84 800-333-0852 www.erico.com ��i.3 t sS-a '���'.. �, ;I i s dm- r > §. .. _.. 4 ',.104.1,y040 ; 491521011111111111111111. Page 86 • Pa• ge 86 Page 87 Page 87 • 107108 • 109 SO • • • • .sy i .ai P 800-333-0852 85 www.erico.com 1 r CPVC PIPE FIXINGS 107 �e r One-hole Wrap Around Strap for CPVC Pipe < • Size Range: 3/4" thru 2" CPVC pipe ` • Surface Finish: Electro-zinc plated :1II • Support CPVC pipe horizontally from top or side of beam • Flared edges protect the CPVC piping Part Nominal A B Max. Hanger Number Pipe Size Spacing 1070075EG 3/4" 1-1/4" ` 2-3/8" 5-1/2' 1070100EG 1" 1-7/16" 2-11/16" 6' 1-3/16" O 1070125EG 1-1/4" 1-5/8" 3-1/16" , 6-1/2' 1070150EG 1-1/2" 1-3/4" 3-5/16" 7' 1070200EG 2" 1-7/8" 3-11/16" 8' .230 DIA. c(1;;11.!1 us — —� A CPVC PIPE FIXINGS 108 Two-hole Strap for CPVC Pipe ' a • Size Range: 3/4" thru 2" CPVC pipe • Surface Finish: Electro-zinc plated • Support CPVC pipe horizontally from top, bottom or side of beams f • Retainer dimples secure hanger to pipe during installation • Flared edges protect the CPVC piping Part Nominal A B Max. Hanger Number Pipe Size Spacing .230 DIA. B 1080075EG 3/4" 3-1/4" 2-1/4" 5-1/2' ---�\ --- 1080100EG. 1' 3-1/2" 2-1/2" 6 1 ISI 1080125EG 1-1/4" 4-1/4" 3-1/4" 6-1/2' 1080150EG 1-1/2" 4-7/16" 3-7/16" 7' A 1080200EG 2" 4-15/16" 3-15/16" 8' 1 r 1 3/16" O I O CU8 ,„ i CADDY, 86 800-333-0852 www.erico.com , � � _ � FIXINGS , •s` �' ,, '','; ';',--:-'2, y s . .[ , r fl' CPVC PIPE FIXINGS 109 ° ' Side Mount Strap for CPVC Pipe • Size Range: 3/4" thru 2" CPVC pipe • Surface Finish: Electro-zinc plated , • Support CPVC pipe horizontally from top or bottom of beam • Retainer dimples secure hanger to pipe during installation • Flared edges protect the CPVC piping , Part Nominal A B Max. Hanger Number Pipe Size Spacing A B 1090075EG 3/4" 2.5/16" 1-11/16" 5-1/2' 1090100EG 1" 2-5/8" 1-15/16"' 6' 0 0 1090125EG 1-1/4" 2-15/16" 2-5/16" 6-1/2' 1090150EG 1-1/2" 3-3/16" 2-1/2" 7' 230 DIA 1090200EG 2" 3-5/8" 3" 8' i -JJ�J� coos , ---1111— � CPVC PIPE FIXING S4 £ 7 ' , ;',4.. Stand-off Two-hole Strap for CPVC Pipe • Size Range: 3/4" thru 2" CPVC pipe ., • Surface Finish: Electro-zinc plated , • Support CPVC pipe off of the vertical face of structural i or composite wood joists with a minimum of 3/8" web thickness • Flared edges protect the CPVC piping Part Nominal A B Max. Hanger Number Pipe Size Spacing SO12A 3/4" 2-11/16" 3-1/4" 5-1/2' . orilmm S016A 1" 2-15/16" 3-1/4" 6' 1 INENTAAW ll ''t S020A 1-1/4" 3-5/16" 3-1/4" 6-1/2' S024A 1-1/2" 3-9/16" 4-1/2" 7' .200 DIA. S032A 2" 4-1/16" 5" 8' (Mh ;- ,. ',A C sJr% Bs \ r2t,::;111';:',,i7‘Il'''''''' :''e:''''' k ,, �� 800-333-0852 87 Ei 1IC13' k www.erico.com i i v