Report (30) i Fire Marshal's Offices , 40 North Division- 14480 SW Jenkins Rd.,Beaverton,OR 97005•PH(503)356-4700•Fax(503)644-2214 Tualatin Valley South Division-7401 SW Washo Ct.,Ste. 101,Tualatin,OR 97062•PH(503)612-7000•Fax(503)612-7003 Fire & Rescue zzzzzz J J J J J J - } } } >- CC CC CC CC CC cc DDDDDD mm m m m m Building Survey Report cc cc wwwWww ZZZZZZ FMZ : (to be filled out by TVF&R) Code Edition: 98OSSC u < < < u u Name of Facility: Canterbury Woods V V) J) N C N N v M .-i o Name of Building: Carriage Buildings, Buildings 1,2,3,5,6 & 7 00 00 00 00 00 00 0 0 0 0 0 0 c Address: SA rn � o o0 0 N N 00 00n 00 01 Owner: Polygon Northwest Telephone No. (360) 695-7700 0 0 0 0 0 0 0 0 0 0 0 0 Architect: Leonard J. Milbrandt Telephone No. (425) 454-7130 0 0 0 0 0 LA 0 0 0 0 0 0 0 N N N N N N Architect Address: a a a a a a DDDODD m m m m m m r-1 (Ni M In to N ITEM. COMM:- DEKARTION 1. Occupancy Type R1 Use 6 unit condo Capacity None 2. Construction Type V-1 hr Year Built 3. Area(Sq.Ft.) Total 7748 Largest Floor 2 Basement None 4. Stories No 2 Height 28'-5" High Rise ❑Y ®N 5 a. Exterior Wall Construction WF-1 h r b. Opening Protection None 6. Interior Wall Construction GB on WF/GB on WT 7. Floor Construction Carpet-CD-Ply-WGL-GB-GB/1 hr 8. Roof Construction Class "C" RS-Roof felt-Ply-WT @ 24" o.c. 9. Attic Draft Stops No. Yes-4 1/2" GB-WT 10a. Occ.Sep. Wall Construction No. Yes-4 GB-WF-Insulation-Airspace-WF-GB b. Opening Protection None l la. Fire Wall Construction No.None PER 98OSSC b. Opening Protection None 12a. Smoke Barrier Wall Construction No. None b. Opening Protection None 13a. Corridor Wall Construction None b. Opening Protection None 14a. Corridor Ceiling Construction None b. Opening Protection None 15a. Shafts No. 4 Type Dryer vent GB-WF 1 hr b. Opening Protection UL Fire caulk Building Survey Report FMZ : (to be filled out by TVF&R) Name of Facility: Carriage Buildings, Buildings 1,2,3,5,6 & 7 ITEM ` COMM. ,DES[RIPTION 16a. Stair Enclosure No. None b. Opening Protection DF 17. Stairs No. 4 18. Ramps No. None 19. Interior Finish Class Room None Exit Enclosure Corridor 20. Exits No. 6 Total WidthNone per 98OSSC 21. Exit Hardware Type Knob 22a. Exit Signs/Illumination None b. Emergency Lighting None 23. Auto Sprinkler Coverage Yes-P 24. Standpipe Class/Locations None 25. Fire Alarm Type/Coverage Yes- 26. Heating,Ventilation&Air Conditioning Type Unit heat Fuel Electric 27. Electrical Installation Romex-Circuit breaker 28. Stage/Platform None 29. Hazardous Area None 30. Other Comments: Alternate Materials&Methods TVF&R Use Only Inspected By: Date No.Attachments Reviewed By: Date Updated