Loading...
Correspondence (3) Sherman Engineering, Inc. (503) 230-8876 Ph 4 I 0 WW Kearney#517, Portland, OR 97209 (503) 226-4745 Fax /45 J',t•Gao - 00,2. 70 MEMORANDUM c73(.eD SGJ 647we,( S7 TO: Mr. Peter Magaro, Architect '' 3, )- 10570 SW Citation Drive Beaverton, OR 97008 / qT3 DATE: June 13. 2007 / / qy� v FROM: Don P Sherman, PE Principal RE: Cedar Ridge plans Hillsboro, Oregon NOTE: This memo is to inform you of our recommendations for a clarification and a change to the original design. On our design we only show one holdown in corners with abutting shear walls because the design forces are required in one direction at a time and one holdown may work for both directions. Make a note that the larger of the two holdowns must be used. Also we understand a STI-1D14 holdown has been misplaced. We recommend using a HTT22 in a epoxy setting per our detail RI. If you have any questions please give me a call. ra 4_..,0:1'—.....N , c.1 .4%‘‘' ni \ 0‘p, id 4 .LI• i aii CC: Dean Grey @Comcast.net ,1r :v.. rile-Magaro061307.doc