Loading...
Plans (4)BUP2015-00351 PROJECT DIRECTORY BUILDING MANAGER: Jones Lang LaSalle 415 NW 11th Avenue Portland, OR 97209 Telephone (503) 546-3670 ARCHITECT: LRS Architects, Inc. 720 NW Davis, Suite 300 Portland, Oregon 97209 Telephone (503) 221-1121 GENERAL CONTRACTOR: Commercial Contractors Inc. 5573 S. 1 st Circle Ridgefield, WA 98642 Telephone (503) 227-4440 DRAWING INDEX SHEET NAME Eric Turner: Eric.Turner@am.jll.00m Cayla Wardenburg: Cayla.Wardenburg@am.jll.com Michelle Startt: MStartt@LRSArchitects.com Darcie McConnaha: DMcConnaha@LRSArchitects.com Jake Money: jake@ccigc.com A001 COVER SHEET A100 GENERAL NOTES & STANDARD MOUNTING HEIGHTS A201 DEMOLITION PLAN & FLOOR PLAN A202 REFLECTED CEILING DEMOLITION PLAN & RCP A301 ENLARGED PLANS & INTERIOR ELEVATIONS & DETAILS A302 INTERIOR DETAILS & DOOR SCHEDULE Bank of the West r0�� 5 c�G Portland Running 6 0 Red Curry zto !t Children of the Sea ger King 10115 SW Nimbus Ave Wl Fanno 6cry Nimbus Ave F 0* C�r°r°k marl � x Is N 1. VICINITY MAP m SCALE. NOT TO SCALE I T EXPRESS EMPLOYMENT PROFESSIONALS T./,. NIMBUS C -EN -TER 10115 SW NIMBUS AVENUE -SUITE 500 PROJECT SUMMARY L GENERAL INFORMATION PROJECT NAME. EXPRESS EMPLOYMENT PROFESSIONALS T.I. PROJECT ADDRESS: 10115 SW NIMBUS AVENUE SUITE 500 TIGARD, OR 97223 PROPERTY ID. W269875 H. APPLICABLE CODES: 2012 INTERNATIONAL BUILDING CODE (IBC) 2014 OREGON STRUCTURAL SPECIALTY CODE (OSSC) 2014 OREGON MECHANICAL SPECIALTY CODE (OMSC) 2014 OREGON FIRE CODE 2014 OREGON ENERGY EFFICIENCY SPECIALTY CODE (OEESC) 2014 OREGON PLUMBING SPECIALTY CODE (OPSC) 2014 OREGON ELECTRICAL SPECIALTY CODE (DESC) Ill. BUILDING STANDARDS: BUILDING CONSTRUCTION TYPE: 111-8 BUILDING OCCUPANCY. B AREA OF WORK.' +/-1, 939 R. S. F. TOTAL TENANT OCCUPANT LOAD: 41 TiGmYRAIRD, OR 97223 PERMIT SET 12.14.15 IV. ADA ACCESSIBILITY UPGRADES: UPGRADES REQUIRED: 1. PROVIDE (1) NEW UNISEX ACCESSIBLE RESTROOM. 2. PROVIDE VERTICAL GRAB BAR AT BOTH RES TROOMS. ALL OTHER ELEMENTS IN THE ALTERED AREA HAVE BEEN UPGRADED ACCORDING TO THE ACCESSIBILITY UPGRADES LIST AS OUTLINED IN OSSC 3411. V. EMERGENCYSYSTEM STANDARDS: 1. BUILDING IS FULLY SPRINKLERED (NFPA 13). MAKE CODE MINIMUM CORRECTIONS AS REQUIRED PER NEW PLAN. 2. PROVIDE EMERGENCY EGRESS LIGHTING FOR THE EGRESS PATH IN ALL PUBLIC AND TENANT SPACES. MINIMUM INTENSITY SHALL NOT BE LESS THAN 1 FOOTCANDLE AT FLOOR LEVEL ALONG THE ENTIRE LENGTH OF THE PATH. CONNECT TO BUILDING ELECTRICAL SYSTEM. 3. PROVIDE EXIT SIGNAGE. EXIT SIGNAGE SHALL BE CONNECTED TO BUILDING POWER SUPPLY WITH BATTERY BACK-UP FOR MIN 1-1/2 HOUR DURATION. DEFERRED SUBMITTALS - DESIGN BUILD ELECTRICAL SYSTEMS LOW VOLTAGE SYSTEMS MECHANICAL SYSTEMS SPRINKLER SYSTEMS PLUMBING SYSTEMS EGRESS LIGHTING GENERAL NOTES THE SITE PLAN AND SUITE LOCATION PLAN ARE FOR REFERENCE ONLY. SEE ALL OTHER PLAN SHEETS FOR CONTRACT DOCUMENT INFORMATION. THE PROJECT SUMMARY IDENTIFIES SOME SPECIFIC OSSC REQUIREMENTS BUT IS NOT INTENDED TO LIST ALL OSSC REQUIREMENTS. BUILDING 2. SITE PLAN SCALE: NOT TO SCALE PLUMBING FIXTURE COUNT REQUIREMENTS (PER TABLE 2902.1) LEVEL OCCUPANCY FIXTURES WATER CLOSETS LAVATORIES DRINKING FOUNTAINS MALE FEMALE MALE FEMALE REQUIRED 1 1 1 1 1 B 0 PROPOSED 1 1 1 1 CODE SUMMARY (SEE EGRESS PLAN BELOW) REQUIRED EXITS PER SECTION 1015 OCCUPANCY SPRINKLERED I REQUIRED I PROVIDED B 1 Y 1 1 1 2 EXIT ACCESS TRAVEL DISTANCE FROM MOST REMOTE POINT PER TABLE 1016.2 OCCUPANCY SPRINKLERED I REQUIRED PROPOSED B I Y 300' MAX 57'-7" COMMON PATH TRAVEL DISTANCE FROM MOST REMOTE POINT BEFORE 2 WAYS PROVIDED PER TABLE 1014.3 OCCUPANCY SPRINKLERED REQUIRED I PROPOSED B I Y I 100' MAX 1 18'-3" pp AREA OF WORK OCCUOPANCY LEGEND (SEE EGRESS PLAN BELOW) C D AREA OF WORK — — — — 44" MIN. EXIT EGRESS PATH B OCCUPANCYGROUP X ROOM OCCUPANT LOAD PER SECTION 1004 (XX) ACCUMULATIVE OCCUPANT LOAD UO UNOCCUPIED SPACE ® EXIT SIGN w/INTEGRATED DIRECTIONAL ARROW WHERE OCCURS AT ALL EXITS, EVERY 100' IN CORRIDORS, AND IN SPACES WHERE 2 MODES OF EGRESS ARE REQUIRED PER SECTION 1011. (REFER TO ELECTRICAL DRAWINGS FOR MORE INFORMATION), POCHE INDICATES "EXIT" TEXT SIDE OF SIGN, SIGNS SHOWN IN CORRIDORS ARE CEILING HUNG. SIGNS SHOWN ON WALL ARE WALL HUNG. E REQUIRED EXIT 3. SUITE LOCATION AND EGRESS PLAN SCALE., NOT TO SCALE LAS ARCH I T E C T S 720 NW Davis 503.221.1121 T Suite 300 503 221.2077 0 Portland OR 97209 www.Irsarchitects.com OF CONSULTANT: PROJECT NUMBER: 215216 Express Employment Professionals T.I. Nimbus Center 10115 SW Nimbus Avenue Suite 500 Ti-addo 22r� ITY TIGAD REVIEWED FOR CODE COMPLIANCE Approved: [ 14-� OTC: Permit #: Address: C( 17il7 Suite #:5fc-i 13y: — Dare- 2 - OFFICE COPY SHEET TITLE: Cover Sheet DRAWN BY: JSS DATE ISSUED: 12.14.15 Ja A001 `' SHEET: LRS AroW.as, Inc. 0 2015 PERMIT SET 12.14.15 GENERAL NOTES GENERAL 1. THE GENERAL NOTES ARE INTENDED TO CONVEY DESIGN INTENT NOT OTHERWISE STATED IN THE DRAWINGS AND SPECIFICATIONS. THE PROJECT INTENT IS TO PROVIDE A COMPLETE WORKING TENANT OR BUILDING IMPROVEMENT. 2. ALL WORK SHALL CONFORM TO THE 2012 INTERNATIONAL BUILDING CODE (IBC), 2014 OREGON STRUCTURAL SPECIALTY CODE (OSSC), 2014 OREGON MECHANICAL SPECIALTY CODE (GMSC), 2014 OREGON FIRE CODE, 2014 OREGON ENERGY EFFICIENCY SPECIALTY CODE (OEESC), 2014 OREGON PLUMBING SPECIALTY CODE (OPSC), 2014 OREGON ELECTRICAL SPECIALTY CODE (OESC) AND TO CONDITIONS AND SPECIFICATIONS OF ALL GOVERNING AUTHORITIES. 3. CAREFULLY EXAMINE THE PROJECT SITE AND CONSTRUCTION DOCUMENTS. VERIFY ALC DIMENSIONS AND CONDITIONS PRIOR TO START OF WORK AND REPORT ANY DISCREPANCIES TO THE ARCHITECT. 4. OBTAIN AND PAY FOR ALL PERMITS AND FEES TO COMPLETE THE WORK OBTAIN AND PAY FOR ADDITIONAL DRAWINGS AND SPECIFICATIONS REQUIRED FOR PERMITS. 5. THE CONTRACTOR SHALL PROVIDE AND PAY FOR DUMPSTER AND TELEPHONE. 6. COORDINATE ARCHITECTURAL WORK WITH MECHANICAL AND ELECTRICAL DESIGN BUILD WORK AND SUBMIT ALL DESIGN BUILD PLANS TO ARCHITECT FOR REVIEW PRIOR TO CONSTRUCTION, 7. DIMENSIONS TAKE PRECEDENCE OVER SCALE. DIMENSIONS ARE TYPICALLY TO FACE OF FINISH UNLESS OTHERWISE NOTED. 8 KEEP PROJECT AREA OF WORK FREE OF GARBAGE AND DEBRIS ON A DAILY BASIS. 9. DO NOT DISTURB ADJACENT TENANTS BY NOISY CONSTRUCTION (i.e., JACK HAMMERING OR CORE DRILLING), OR ODORS (i.e., PAINTING OR ADHESIVE FROM FLOOR OR WALL COVERINGS), SCHEDULE SUCH ACTIVITIES FOR AFTER NORMAL BUSINESS HOURS. COORDINATE SUCH ACTIVITIES WITH BUILDING OWNER. 10. STORAGE OUTSIDE OF BUILDING IS NOT ALLOWED WITHOUT AUTHORIZATION BY BUILDING OWNER. 11. OWNER SHALL NOT BE RESPONSIBLE FOR TOOLS OR MATERIAL GOODS STOLEN OR DAMAGED ON SITE. 12. CONTACT OWNER'S REPRESENTATIVE TO COORDINATE SCHEDULED ITEMS TO BE SALVAGED FOR RETURN 13. UPON COMPLETION OF WORK, BE RESPONSIBLE FOR RETURN TO OWNER OF ALL MASTER KEY ORIGINALS OR CARD ACCESS DEVICES. 14. WARRANTYALL PARTS, LABOR, EQUIPMENT; AND MATERIAL PROVIDED UNDER THIS CONTRACT OF A PERIOD OF ONE YEAR, UPON FINAL COMPLETION OF CONTRACT. 15 SUBMIT SUBSTITUTION REQUESTS ON CSI FORM TO ARCHITECT FOR APPROVAL ARCHITECT'S DECISION IS FINAL WHETHER A PROPOSED PRODUCT IS ACCEPTABLE FOR SUBSTITUTION. 16. APPLICATION OF MATERIALS TO SURFACES EXISTING OR PROVIDED UNDER THIS CONTRACT IMPLIES ACCEPTANCEAND SUITABILITY OF EXISTING CONDITIONS. 17. ALL WORK INDICATED ON DRAWINGS SHOULD BE CONSIDERED NEW UNLESS IDENTIFIED AS EXISTING TO REMAIN OR TO BE REUSED. 18. ALL MATERIALS AND PRODUCTS USED ON THE JOB SITE SHALL BE "ENVIRONMENTALLY SAFE", LOW ODOR AND NONFLAMMABLE. USE OF ANY PRODUCT NOT COMPLYING WITH THIS CRITERIA MUST BE APPROVED BY THE BUILDING OWNER. 19. CONTRACTOR WILL BE HELD RESPONSIBLE FOR ANY DAMAGE OR CLEANING THROUGHOUT STRUCTURE DEEMED TO BEA RESULT OF HISIHER WORK THOROUGHLY CLEAN PREMISES UPON COMPLETION OF WORK, INCLUDING WASHING OF WINDOWS, SO THAT BUILDING IS READY FOR OCCUPANCY BY TENANT. INCLUDE CLEANING OF ADJACENT AREAS WITHIN AND AROUND THE BUILDING THAT ARE NOT PART OF TENANT IMPROVEMENTS, BUT WERE AFFECTED BY TENANT IMPROVEMENT CONSTRUCTION OPERATIONS. 20. CONTRACTOR TO PROVIDE MECHANICAL AND ELECTRICAL AS -BUILT DRAWINGS, ALL WARRANTIES AND OPERATING MANUALS TO BUILDING OWNER WITHIN TWO WEEKS OF COMPLETION OF WORK. CONTRACTOR ALSO IS TO PROVIDE FINAL CERTIFICATE OF OCCUPANCY NO RETAINAGE SHALL BE RELEASED UNTIL OWNER HAS RECEIVED THESE ITEMS. 21. WHENEVER REMODEL WORK REQUIRES THE TENANTS FURNITURE TO BE MOVED, MONIES ARE TO BE INCLUDED FOR AN OFFICE FURNITURE MOVING COMPANY TO COMPLETE THIS WORK. PACKING AND UNPACKING ARTWORK PERSONAL BELONGINGS, LOOSE ITEMS ON DESK AND SHELVES, AS WELL AS ITEMS WITHIN DESKS AND FURNITURE, WILL BE COMPLETED BY THE TENANT. 22 ALL DEMOLITION WORK TO CONFORM TO CURRENT OSHA STANDARDS. PROVIDEADEQUATE BRACING ON EXISTING CEILING FRAMING SYSTEM PRIOR TO DEMOLITION DOOR AND HARDWARE 23. DOORS SHALL OPEN FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. CLEAR FLOOR SPACE CLEAR FLOOR SPACE PARALLEL APPROACH FORWARD APPROACH Fig. 308.2.2 OBSTRUCTED HIGH FORWARD REACH L . 10° MAX L _ > 10" - 24° Fig. 3082.1 UNOBSTRUCTED FORWARD REACH �10. MAX Fig. 308.3.1 UNOBSTRUCTED SIDE REACH z 00 A LIMITS OF PROTRUDING OBJECTS EXCEPTIONS: 1. HANDRAIS MAY PROTRUDE 41/2*MAX, Z DOOR CLOSEST AND DOORSTOPS SHALL BE PERMITTED TO BE 78* MIN ABOVE FLOOR 24. NEW DOOR HARDWARE SHALL MATCH EXISTING BUILDING STANDARD LEVER HANDLE WITH FINISH TO MATCH BUILDING STANDARD. FINISH OF HINGES AND CLOSERS TO MATCH. ALL HARDWARE SHALL BE ADA ACCESSIBLE. 25 CONTRACTOR SHALL VERIFY COMPATIBILITY OF HARDWARE SPECIFIED WITH BUILDING KEYING SYSTEM. 26. PROVIDE NEW DOORS MATCHING EXISTING DOORS' VENEER SLICING PATTERN AND GRAIN DENSITY, AND FINISH. 27. PROVIDE CLOSERS ON ALL TENANT ENTRY OR EXIT DOORS TO MATCH EXISTING BUILDING STANDARD FINISH AND TYPE. 28 PROVIDE DOOR OPENINGS IN RATED WALLS COMPLYING WITH REQUIRED SMOKE CONTROL ASSEMBLYAND INDICATED FIRE PROTECTION RATING OF NO LESS THAN 20 MINUTES. WHERE EXISTING DOOR OPENINGS DO NOT COMPLY WITH PRESENT BUILDING CODE REQUIREMENTS, PROVIDE NEW DOORS, FRAMES AND HARDWARE THAT COMPLY. 29. ADJUST THE RESISTIVE FORCE OF ALL NEW AND EXISTING INTERIOR DOOR CLOSERS IN THE PROJECT AREA TO A MAXIMUM PRESSURE OF 5 LBS. TO COMPLY WITH ADA REQUIREMENTS. FINISHES 30 REPAIR / REFINISH ANY DAMAGE TO EXISTING FINISH SURFACES IN IMPROVEMENT AREA CAUSED BY CONSTRUCTION OPERATIONS. 31. PAINT EXISTING WALLS WITH 2 COATS OF EGGSHELL FINISH PAINT UNLESS OTHERWISE NOTED. SUBMIT COLOR DRAW -DOWNS TO ARCH/TECTAND OWNER FORAPPROVAL PRIOR TO APPLICATION. 32 WHERE ALL NEW PARTITIONS ABUT, JOIN OR CONNECT TO EXISTING SURFACES, WALLS, OR NEW CONSTRUCTION, THE FINISHED SURFACE SHALL BE ALIGNED FLUSH. 33. ALL NEW WALLS AND PARTITIONS SHALL HAVE TAPED JOINTS (3) COATS SANDED AND PRIMED TO MEET PAINT READY REQUIREMENTS. 34. EXISTING WALLS AND SURFACES SHALL BE STRIPPED, RESURFACED, AND PATCHED AS REQUIRED. 35. DISPOSE OF ALL PAINT MATERIALS OFF SITE DO NOT POUR DOWN DRAINS, CATCH BASINS, OR IN LANDSCAPING. 36. PROVIDE A FULL GALLON OF EACH WALL COLOR WITH LABELS IN TENANT CLOSET OR UNDER SINK, LABEL ALL LEFT OVER PAINT, AND DELIVER TO OWNER WHERE DIRECTED. 37. TAPE AND SAND EXPOSED GYPSUM BOARD FOR A FLAT, SMOOTH SURFACE FINISH TO MATCH EXISTING ADJACENT SURFACES IN BUILDING, UNLESS OTHERWISE INDICATED. 38. PROVIDE FINISH MATERIALS MATCHING ESTABLISHED BUILDING STANDARD QUALITY; UNLESS OTHERWISE INDICATED. PROVIDE COLORS APPROVED BY OWNER AND ARCHITECT. 39 CONTRACTOR TO FILL AND PATCH EXIST7NG CONCRETE SLABS AND SHALL PROVIDE SMOOTH UNIFORM SURFACE PRIOR TO NEW FLOOR COVERINGS TO BE INSTALLED. SPECIALTIES 40. FIRE EXTINGUISHER REQUIREMENTS: SURVEY EXISTING CONDITIONS OF ENTIRE FLOOR THAT PROJECT OCCURS, AND PROVIDE NOT LESS THAN ONE APPROVED FIRE EXTINGUISHER WITH RATING OF NOT LESS THAN 2A 10BIC FOR EACH 1,500 S.F. OF FLOOR AREA OR FRACTION THEREOF. TRAVEL DISTANCE TO AN EXTINGUISHER FROM ANY PORTION OF THE BUILDING SHALL NOT EXCEED 75 FEET. PROVIDE FIRE EXTINGUISHER IN ACCORDANCE WITH CURRENT CODES. PROVIDE NEW FIRE EXTINGUISHER AT ALL EXISTING CABINETS WHERE MISSING. ALL REUSED EXISTING FIRE EXTINGUISHERS ARE TO BE INSPECTED ANDIOR RECHARGED, AS NECESSARY, JUST PRIOR TO SUBSTAN77AL COMPLETION. FURNISHINGS 41. INSTALL BUILDING STANDARD WINDOWCOVERINGS AT ALLPERIMETER WINDOWS IN IMPROVEMENT AREA UNLESS OTHERWISE NOTED. 42. FURNITURE INDICATED ON PLANS IS FOR REFERENCE ONLY AND SHALL BE CONSIDERED NOT IN CONTRACT. MECHANICAL - DESIGN BUILD 43. MECHANICAL SYSTEM AND REQUIREMENTS ARE DESIGN -BUILD. SUBMIT PLANS AND SPECIFICATIONS TO ARCHITECT FOR COORDINATION WITH ARCHITECTS DRAWINGS, IN ADDITION, CONTRACTOR SHALL PROVIDE WITH SUBMITTAL (2) COPIES OF A COLORED FLOOR PLAN DESIGNATING WHICH AREAS ARE CONTROLLED BY EACH THERMOSTAT MECHANICAL DESIGN MUST BE APPROVED BY OWNER AND MECHANICAL ENGINEER IF EMPLOYED BY ARCHITECT PRIOR TO CONSTRUCTION. 44. PAY ALL FEES AND OBTAIN ALL PERMITS AND APPROVALS FROM GOVERNING AGENCIES NECESSARY TO COMPLETE WORK 45. COORDINATE ITEMS REQUIRED FOR DEMOLITION NOT INDICATED ON DRAWINGS. EXIT SIGN TYPICAL DOOR OPENING 9" TO RAISED r --t CHARACTERS TYPICAL ATDOOR :SSORY ZONE TOILET - RECESSED MOUNT ACCESSORYZONE (SECTION 604.7) CARD READER 46. COORDINATE ELECTRICAL REQUIREMENTS FOR MECHANICAL SYSTEM. 47. DESIGN -BUILD CONTRACTOR SHALL PREPARE WRITTEN SCOPE OF HVAC WORK WITH BID. THIS IS TO INCLUDE NEW EQUIPMENT, NUMBER OF ZONES, DESCRIPTION AND QUANTITY OF CONTROLS AND THERMOSTATS, ETC. OWNER WILL REVIEW SCOPE OF WORK PROPOSED PRIOR TO ACCEPTANCE OF BID. 48. DESIGN -BUILD CONTRACTOR TO PROVIDE CERTIFICATION THAT OUTDOOR AIR REQUIREMENTS OF CURRENT CODES WILL BE MET FOR EACH OCCUPANCY USE WITHIN THE TENANT IMPROVEMENT AREA 49. INTERIOR AND PERIMETER OFFICES SHALL NEVER BE ON THE SAME ZONE. CONFERENCE ROOMS AND LUNCHROOMS CAPABLE OF SEATING (6) OR MORE SHALL ALWAYS BE ON THEIR OWN ZONE 50. DESIGN -BUILD CONTRACTOR SHALL VERIFY THE SUITABILITYAND CONDITION OF SCHEDULED EQUIPMENT TO BE RE -USED OR RELOCATED. DETERMINE ITEMS THAT NEED TO BE REPAIRED OR REPLACED. PRICE THESE ITEMS SEPARA TEL YAND AS EXCEPTIONS / CLARIFICATIONS IN BID. 51. AUTOMATIC SPRINKLER SYSTEM SUPERVISION: ALL VALVES, INCLUDING THOSE IN PITS, SHALL BE MONITORED BY UL LISTED FIRE MARSHAL -APPROVED CENTRAL STATION WATER FLOW AND HIGWLOW PRESSURE FOR DRY PIPE SYSTEMS IF USED) SHALL BE SUPERVISED, AS WELL AS OTHER FEATURES DEEMED NECESSARY BY CURRENT NATIONAL FIRE PROTECTION ASSOCIATION STANDARDS. 52. PREPARE SPRINKLER SYSTEM SHOP DRAWINGS FOR COORDINATION WITH ARCHITECTS DRAWINGS BYARCHITECT. 53. PAY ALL FEES AND OBTAIN ALL PERMITS AND APPROVALS FROM GOVERNING AGENCIES NECESSARY TO COMPLETE THE WORK 54. PROVIDE FIRE DAMPERS AS REQUIRED BY CURRENT OSSSC STANDARDS FOR NEW CONFIGURATION OF FIRE -RATED PARTITIONS. 55. BALANCE DESIGN -BUILD HVAC SYSTEM TO TENANT AND BUILDING OWNERS SATISFACTION. TOUR EXISTING CONDITIONS AND CONTACT OWNER FOR QUESTIONS PRIOR TO BID. 56. INSTALL TEMPORARY FILTERS ON HVAC VAV BOXES AFFECTED BY WORK OF PROJECT PRIOR TO CONSTRUCTION. REMOVE FILTERS AT COMPLE77ON OF THE PROJECT 57. COORDINATE ZONE CONTROL OF EXISTING HVAC SYSTEM AT IMPROVEMENT AREA. SEPARATE AND REROUTE EXISTING DUCTWORK AND CONTROLS REQUIRED TO PROVIDE INDEPENDENT OPERATION BY TENANTS ON EACH SIDE OFA DEMISING WALL. 58. CLEAN ALL NEWAND EXISTING HVAC GRILLS AND DIFFUSERS SCHEDULED TO REMAIN. ALL DUCTWORK BEHIND GRILLS SHALL BEA UNIFORM DARK COLOR. 59. DESIGN -BUILD CONTRACTOR AT COMPLETION SHALL PREPARE AND SUBMIT AN AIR BALANCING REPORT TO THE OWNER. 60. HVAC CONTRACTOR TO PROVIDE 100% FRESH AIR SUPPLIED TO ENTIRE TENANT SPACE THREE CALENDAR DAYS PRIOR TO THE FIRST DAY AFTER SUBSTANTIAL COMPLETION. PROVIDE 100% FRESH AIR WITHOUT MAKING OTHER TENANTS UNCOMFORTABLE ELECTRICAL - DESIGN BUILD 61. ELECTRICAL SYSTEM AND REQUIREMENTS ARE DESIGN -BUILD. SUBMIT ELECTRICAL DESIGN TO ARCHITECT FOR COORDINATION WITH ARCHITECTS DRAWINGS PRIOR TO CONSTRUCTION. 62. IF AN OVERRIDE SYSTEM EXISTS, PROVIDE EACH TENANT SPACE WITH AN OVERRIDE SWITCH FOR FULL-SERVICE BUILDINGS. 63. PAY ALL FEES AND OBTAIN ALL PERMITS AND APPROVALS FROM GOVERNING AGENCIES NECESSARY TO COMPLETE WORK 64. COORDINATE ITEMS REQUIRED FOR DEMOLITION NOT INDICATED ON DRAWINGS. 65 COORDINATE ELECTRICAL REQUIREMENTS FOR MECHANICAL SYSTEMS. 66. DESIGN -BUILD CONTRACTOR SHALL PREPARE WRITTEN SCOPE OF ELECTRICAL WORK TO BE PERFORMED TO THE OWNER WITH BID. 67. ELECTRICAL LIGHTING ON DRAWINGS IS PROVIDED FOR REFERENCE ONLYAND IS INTENDED TO SHOW FIXTURE TYPES AND LOCAPONS. ELECTRICAL DESIGN IS BY DESIGN -BUILD CONTRACTOR IN ACCORDANCE WITH EXISTING BUILDING STANDARDS. COMPLY WITH ENERGY CODE REQUIREMENTS AS REQUIRED BY CURRENT ENERGY CODES AND PROVIDE ENERGY CALCULATIONS REQUIRED FOR WORK OF THIS PROJECT. 68. SWITCHING FOR LIGHTING IS INDICATED IN THE DRAWING FOR REFERENCE ONLY AND IS INTENDED TO ONLY SHOW STITCH LOCATIONS. REQUIREMENTS FOR DUAL SWITCHING, AUTOMATIC AREA SHUT OFF CONTROLS AND ALL OTHER CODE REQUIREMENTS SHALL BE THE RESPONSIBILITY OF THE DESIGN -BUILD CONTRACTOR. PROVIDE A MINIMUM OF ONE SWITCH PER ROOM, UNLESS OTHERWISE INDICATED. 69. PROVIDE ILLUMINATED EXIT SIGNS AT REQUIRED EXIT DOORWAYS AND WHERE NECESSARY TO INDICATE THE DIRECTION OF EGRESS WHEN THE EXIT SERVES AN OCCUPANT LOAD OF FIFTY OR MORE. 70. PROVIDE ILLUMINATION AT EXITS WITH LIGHT HAVING THE INTENSITY OF NOT LESS THAN 1 FOOT-CANDLE AT THE FLOOR LEVEL PROVIDE EMERGENCY SYSTEM LIGHTING WHERE THE EXISTING SYSTEM SERVES AN OCCUPANT LOAD OF A 100 OR MORE AS REQUIRED BY CODE. - TOWEL DISPENSER AND WASTE RECEPTACLE HAND DRYER COAT &UTILITY SOAP ,° � .° HOOK DISPENit­ 0 0 0 CO W)! CO * O �v v 0 ELECTRICAL OUTLET ELECTRICAL OUTLET TELEPHONE AT CASEWORK OUTLET AND SWITCHES c+j -- - - MO ¢z O Z � r- �2 .:v0 MISCELLANEOUS WALL MOUNTINGS � 12° MAX T-4" TOILET ROOM MOUNTINGS Li 0 LL! W z C3 0 36" GRAB BAR 18" VERTICAL OPERABLE THERMOSTAT REFLECTIVE MOUNTED PHONE MANUAL PULL GRAB BAR STATION iy 17* TO 25" r_ m 9 C1 0 0 0 et LL 0 co co v v FIRE ALARM SIGNALISTROBE FIRE EXTINGUISHER SIGN RECESSED FIRE EXTINGUISHER CABINET INTERCOM STATION Z 0 � m 0 24" W41111,11 MATCH EXISTING BUILDING STANDARD WHERE POSSIBLE FOR REQUIRED EMERGENCY SYSTEMS AND INSTALL IN ACCORDANCE WITH THE REQUIREMENTS OF THE CURRENT NATIONAL ELECTRICAL CODE 71- PROVIDE VISUAL AND AUDIBLEALARM SIGNAL APPLIANCES INTEGRATED INTO THE BUILDING ALARM SYSTEM AS REQUIRED BY ADA AND CURRENT OSSSC STANDARDS. PROVIDE ADDITIONAL ELECTRICAL SERVICE AS REQUIRED. COORDINATE REQUIREMENTS WITH BUILDING OWNER. ALARM LOCATIONS INDICATED ON PLANS ARE ONLY FOR REFERENCE. 72. PROVIDE SHOP DRAWINGS FOR ALARM SYSTEM LAYOUT AS REQUIRED BY CODE. 73. VERIFY SERVICEABILITY AND REUSABILITY OF EXISTING ELECTRICAL EQUIPMENT, AND REPAIR OR REPLACE AS NECESSARY. 74. VERIFY THE CAPACITY AND REUSABILITY OF EXISTING ELECTRICAL PANELS TO MEET PROJECT REQUIREMENTS. 75. TERMINATE ALL CONDUITS IN STANDARD DUPLEX BOXES, UNLESS OTHERWISE INDICATED. 76. KNOWN EXISTING (E) ELECTRICAL AND PHONE/DATA OUTLETS HAVE BEEN INDICATED ON THE DRAWING. ADDITIONAL EXISTING OUTLETS MAY EXIST AND SHOULD BE VERIFIED BY CONTRACTOR. 77. VERIFY WITH TENANT OR OWNER LOCATIONS OF ELECTRICAL AND VOICEIDATA OUTLETS FOR SYSTEMS FURNITURE PRIOR TO INSTALLATION. 78. SMOKE DETECTION DEVICES INDICATED ON THE DRAWINGS ARE FOR REFERENCE ONLY. CONFIRM SPACING OF DETECTORS WITH DEVICE LISTING. 79. CLEAN AND REPAIR EXIS77NG SMOKE DETECTORS TO BE REUSED TO GOOD WORKING CONDITION, 80 CLEAN NEW, EXISTING, AND RELOCATED LIGHT FIXTURES IN PROJECT AREA, OR IN AREAS AFFECTED BY WORK OF THIS PROJECT, AT COMPLETION OF JOB. RELAMP AND REPLACE BALLAST IN LIGHT FIXTURES AS REQUIRED TO RESTORE TO WORKING ORDER. 81. CLEAN AND REPAIR EXISTING EXIT SIGNS TO BE REUSED. REPLACE BATTERY ANDIOR BALLAST IF NOT IN GOOD WORKING CONDITION. 82 COORDINATE TELECOMMUNICATIONS AND MODIFICATION TO BUILDING ALARM SYSTEM PROVIDED BY TENANT. VERIFY WITH TENANT LOCATION OF NEW OUTLETS PRIOR TO INSTALLATION. 83 REMOVE ALL UNUSED OR ABANDONED ELECTRICAL WIRING, EQUIPMENT, AND PHONE AND DATA CABLING. CONFIRM WITH OWNER PRIOR TO REMOVAL. ALL WIRING AND CABLING TO REMAIN SHALL BE SUSPENDED FROM STRUCTURE AS REQUIRED BY CURRENT CODE. SCHEDULING OF FIRE SPRINKLER AND ALARM SYSTEMS 84. CONTACT OWNER'S REPRESENTATIVE FOR INSTRUCTIONS WHEN SCHEDULING WORK ON FIRE SPRINKLER & ALARM SYSTEMS. ACCESSIBLE FIXTURE MOUNTING REQUIREMENTS 85 ALL DIMENSIONS INDICATED ON THIS SHEET ARE CLEAR MINIMUM TO FACE OF FINISH. DIMENSIONS TO TOILET ROOM ACCESSORIES ARE TO THE CENTER LINE AS NOTED OR TO THE HIGHEST PORTION OF THE OPENING OR OPERATING DEVICE. 86. ALL ITEMS INDICATED BELOW MAY NOT OCCUR ON THIS PROJECT. SEE PROJECT PLANS AND ELEVATIONS FOR ITEMS THAT OCCUR. SEE ARCHITECTURAL PLANS FOR ACCESSIBILITY ANDIOR ADAPTABILITY CONFORMANCE IN THE HORIZONTAL PLAN LAYOUT 87. CONFORMANCE TO FIXTURE MOUNTING HEIGHT REQUIREMENTS AREAPPUCABLE IN ANY PUBLIC AREA OR EMPLOYEEAREA MORE THAN 1000 SF, AS THEY OCCUR PER PROJECT. 88. VERIFY ACCESSORY SIZE WITH MANUFACTURER TO ENSURE CONFORMANCE WITH REQUIRED MOUNTING HEIGHTS. 89. PROVIDE CODE -COMPLIANT BLOCKING tMTHIN WALLS AS REQUIRED FOR PROPOSED AND FUTURE ACCESSORIES AND GRAB BAR MOUNTING FIXTURES. BLOCKING IS REQUIRED FROM STUD SPACE TO BACK OF SURFACE OF ALL FIXTURES INCLUDING BUT NOT LIMITED TO TUBISHOWER ENCLOSURES. 90. FLOOR DRAINS: ACCESSIBLE FIXTURES REQUIRE A CLEAR FLOOR SPACE CONTIGUOUS OR OVERLAPPING THE ACCESSIBLE ROUTE. FLOOR DRAINS SHOULD NOT BE PLACED IN THIS CLEAR FLOOR SPACE. EXCEPTION. DRAINS MAY RESIDE IN CLEAR FLOOR SPACE PROVIDED DRAIN HOLES DO NOT EXCEED 112" DIA. MAX; FLOOR SLOPE DOES NOT EXCEED 2% IN ANY DIRECTION,' AND THE ELEVATION CHANGE AT THE DRAIN LIP DOES NOT EXCEED 118". END OF GENERAL NOTES SORY ZONE 0j TOILET- SURFACE MOUNT ACCESSORY ZONE (SECTION 604.7) ANNUNCIATOR PANEL WALL MOUNTED FIRE EXTINGUISHER 010j z Z ,, IND-RWI EMERGENCY POWER OFF PUSH BUTTON TACTILE SIGNAGE BASE OF CHARACTER 0j z o ct Tr c0 O REFLECTIVE SHELF AND --` GRAB BAR iy EMERGENCY POWER OFF PUSH BUTTON TACTILE SIGNAGE BASE OF CHARACTER 0j z o ct Tr c0 O REFLECTIVE SHELF AND --` GRAB BAR iy 17* TO 25" SURFACE POLE 42* GRAB BAR 12" MIN LAVATORY & LAV IN COUNTER 8" MIN 8 LAV 5 >= co W Q M CL 0 � 0 t1 M 0 INSULATE EXPOSED HOT WATER z SUPPLY AND O o O * 14 DRAIN �r m ° M z _ m �, �* 18" VERTICAL PIPES TYP N I�L" GRAB BAR SIDE APPROACH m 18' 42* GRAB BAR 66 MAX 11' IN MIRRORS (SECTION 603.3) SHELVES (SECTION 603.4) WATER CLOSET (SECTION 604) FLUSH CONTROLS ON WATER CLOSET- PLAN LAVATORY AND SINKS (SECTION 606) OPEN SIDE OF WATER CLOSET (SECTION 604) 1. ACCESSIBLE FIXTURE MOUNTING REQUIREMENTS (PER ICC/ANSI A11 7.1-2009) SCALE NOT TO SCALE ARCHITECTS 720 NW Davis 503.221.1121 IM Suite 300 503 221.2077 L1 Portland OR 97209 www.irsarchftects.com CONSULTANT. PROJECT NUMBER: 215216 Express Employment Professionals T.I. Nimbus Center 10115 SW Nimbus Avenue Suite 500 Tigardi OR 97223 SHEET TITLE: General Notes & Standard Mounting Heights DRAWN BY: JSS DATE ISSUED: 12.14.15 SHEET: A100 CRS Architects, Inc. 02015 PERMIT SET 1 2.14.1 5 1. DEMOLITION PLAN SCALE. 1/8" = 1'-0" DEMO PLAN GENERAL NOTES 1. REFER TO SHEET A100 FOR A COMPLETE LIST OF GENERAL NOTES. 2. REMOVE EXISTING FLOORING & BASE UNLESS OTHERWISE NOTED. WHERE STAINED CONCRETE IS CALLED OUT, REMOVE ALL EXISTING CARPET GLUE AND GRIND/BUFF FLOORS PRIOR TO STAINING. 3. PROTECT ALL ADJACENT AREAS DURING DEMOLITION & FROM DUST AND TRASH INTRUSION. PATCH AREAS ADJOINING ANDIOR ADJACENT TO DEMOLITION WORK TO MATCH EXISTING AND/OR NEW CONSTRUCTION. 4. REMOVE & SALVAGE DOORS, FRAMES, & RELITES FOR REUSE. 5. REMOVE BLINDS & WINDOW COVERINGS FOR REUSE. CLEAN AND REINSTALL PRIOR TO JOB COMPLETION. REPAIR AND/OR REPLACE ANY MISSING AND/OR DAMAGED WINDOWCOVERINGS TO MATCH EXISTING AS NEEDED THROUGHOUT ENTIRE AREA OF WORK. 6. REMOVE AND SALVAGE FIRE EXTINGUISHERS & CABINETS FOR REUSE. PROVIDE AS REQUIRED BY CODE. DEMO PLAN KEYNOTES 01 REMOVE EXISTING WALL MOUNTED SINK. RELOCATE LIGHT SWITCH. 3 LEGEND Lf 2 3 7 0 a EXISTING PARTITION A R C H I T E C T S 720 NW Davis 503.221.112111 SERVER DEMOLISH EXISTING ELEMENT AS NOTED C ADA UNISEX C PT -1 SCONC 107 Suite 300 503 221.2077 D 106 �\ UNISEX 105 o v ( 7 O ® 56" HIGH PARTIAL HEIGHT WALL (SEE DETAIL Portland OR 97209 www.IrsarChitecis.Com A301 2 301 N 8/301) N A ' N A N108 EP NEW BUILDING STANDARD PARTITION 2• sv� CPT -1 CPT -1 scos �_ 4 F N105 A N (SEE DETAIL 1/302) � OS N >. BREAKROOM ® RELITE PARTITION op v ¢ 108L ?1 q 6 O DOOR FRAME & RELITE TYPES C STAIIIT kl301 CD (SEE 11 /A302) or '9-6ITV P) e_- J _ Q NYN 4N • LSal r PWRM LN� n—� NEW RELITE PARTITION .�����.[7?�� N� �Y �N �, ` ,I j N BELOW ITEMS SHOWN FOR REFERENCE ONLY0� LL ---------- OPS MGR OFFICE N $ SWITCH BULLPEN b O N fog $OS SWITCH wl OCCUPANCY SENSOR ME r 1 N109 Jos N P TELE / DATA OUTLET CONSULTANT: N DUPLEX OUTLET rr1� O N 9$" QUAD OUTLET L TYP N N rl ® N �_ LL E EXISTING - - BRANCHMNGR — N NEW OFFICE --� 110 R RELOCATED 71Q N �i N FE FIRE EXTINGUISHER TESTING 103 10o �� 1 Cir - T I 1 11' . l N APPLICATIONS 8 N 102 1II,2FIS SCONC 2. FLOOR PLAN SCALE. 116"= V-0" v �l cPr-1 O o ¢ r 2 SCONC RECEPTION 101 X4 FLOOR PLAN GENERAL NOTES 1. REFER TO SHEET A100 FOR A COMPLETE LIST OF GENERAL NOTES. 2. DIMENSIONS ARE TO FACE OF WALL UNLESS OTHERWISE NOTED. ADVISE ARCHITECT OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 3. ALL ELECTRICAL WORK IS DESIGN BUILD - ALL ELECTRICAL OUTLETS, DATA & SWITCHES SHOWN FOR REFERENCE ONLY. VERIFY EXISTING CONDITIONS. SUBMIT ELECTRICAL PLANS TO ARCHITECT FOR REVIEW PRIOR TO CONSTRUCTION. ASSUME TYPICAL OFFICE ENVIRONMENT THROUGHOUT, 4. PATCH AREAS ADJOINING AND/OR ADJACENT TO DEMOLITION WORK TO MATCH EXISTING AND/OR NEW CONSTRUCTION. 5. SOUND CAULK ALL WALL/GLASS & WALUMULLION JOINTS. 6. PROVIDE NEW FLOORING & BASE UNLESS OTHERWISE NOTED. 7. REPAINT ENTIRE SUITE UNLESS OTHERWISE NOTED. ASSUME MIN OF (5) ACCENT WALLS - LOCATIONS TO BE DETERMINED. 8. WHERE NEW DOORS, FRAMES & HARDWARE ARE PROVIDED, MATCH EXISTING BUILDING STANDARD TYPE, SIZE, FINISH & COLOR. TOUCH UP EXISTING FRAMES & DOORS WHERE NEEDED TO APPEAR AS NEW. REPLACE ALL EXISTING "ORB" STYLE DOORKNOBS WITH ADA LEVERS TO MATCH EXISTING, 9. PROVIDE J -BOX AND PULL STRING FOR TENANT -SUPPLIED VOICE & DATA. ALL DATA LOCATIONS SHOULD BE SERVICEABLE POST CONSTRUCTION SO HARD LID AREAS REQUIRE CONDUIT TO OPEN SPACE. ALL DESK LOCATIONS NEED A DATA LOCATION WITH MUD RINGS AND STRING OR CONDUIT, SUITE MUST HAVE SERVICEABLE CONDUIT FROM BUILDING DMARC TO SUITE OR OTHER ACCESSIBLE CABLE PATHWAY. 10. ALL FURNITURE SHOWN DASHED FOR REFERENCE ONLY AND TO BE PROVIDED BY TENANT. PROJECT NUMBER: 215216 SHEET: A201 LRS Architects, Inc. ® 2015 PERMIT SET 12.14.15 Express Employment FLOOR PLAN KEYNOTES Professionals T.I. OPROVIDE LOUVER IN DOOR TO SERVER. PROVIDE A DEDICATED 20 AMP QUAD OUTLET FOR Nimbus Center TENANT PROVIDED SERVER AND STORE ROOM LOCK AT DOOR. PROVIDE A 4'x 4' PAINTED FIRE TREATED PLYWOOD BACKERBOARD FOR PHONEIDATA TERMINATION. VERIFY LOCATION 10115 SW Nimbus Avenue w/TENANT. Suite 500 OPROVIDE NEW ACCESSIBLE 48" WIDE PLASTIC LAMINATE COUNTER WITH PORCELAIN SINK Tigard, OR 97223 AND AUTOMATIC FAUCET. PROVIDE VERTICAL GRAB BAR AT TOILET. PROVIDE NEW FLOORING AND BASE. O3 INSTALL NEW OR RELOCATED DOOR AND HARDWARE AS REQUIRED FOR NEW DOOR SWING. PROVIDE OCCUPANCY INDICATOR AT DOOR IF NOT ALREADY EXISTING. OPROVIDE POWER, DATA AND BLOCKING IN WALL FOR TENANT PROVIDED TELEVISION. COORDINATE EXACT LOCATION WITH TENANT PRIOR TO CONSTRUCTION. O5 PROVIDE NEW PARTIAL HEIGHT GYP WALL WITH A PLASTIC LAMINATE TRANSACTION COUNTER, WORKSURFACE WITH GROMMETS (LOCATIONS TBD), CABINETS AND FACE OF DESK (PROVIDE 36" WIDE MIN AT ADA HEIGHT). PROVIDE TWO (2) DUPLEX OUTLETS AND TWO (2) LOW VOLTAGE DROPS. O6 PROVIDE ACCESSIBLE PLASTIC LAMINATE CASEWORK, STAINLESS STEEL SINK, GOOSENECK FAUCET, AND WATERLINE FOR TENANT PROVIDED REFRIGERATOR AND COFFEE SYSTEM. PROVIDE TWO (2) DEDICATED CIRCUITS FOR TENANT PROVIDED REFRIGERATOR AND MICROWAVE. PROVIDE PHONE JACK BY DOOR. O7 PROVIDE LOCKABLE PLASTIC LAMINATE CABINET WITH ADJUSTABLE SHELVES. O8 PROVIDE ALUMINUM/GLASS STOREFRONT DOOR, FRAME, ACCESSIBLE HARDWARE AND 7' HIGH RELITE WHERE SHOWN. SHEET TITLE: OEACH WORKSTATION AND DESK THROUGHOUT AREA OF WORK TO HAVE A MINIMUM OF ONE Demolition Plan (1) DUPLEX OUTLET AND ONE (1) LOW VOLTAGE DROP. 10 BUILDINGPROVIDE STANDARD PLASTIC LAMINATE UPPER CABINETS ABOVE TENANT & Floor Plan PROVIDED FILES. O11 PROVIDE BUILDING BUILDING STANDARD PLASTIC LAMINATE WORKSURFACE WITH COMPUTER STORAGE BELOW. PROVIDE ONE (1) QUAD OUTLET AND ONE (1) LOW VOLTAGE DROP FOR EVERY TWO COMPUTERS. 12 TENANT TO PROVIDE FURNITURE FOR TESTING AREA. PROVIDE ONE (1) QUAD OUTLET AND ONE (1) LOW VOLTAGE FOR EVERY TWO COMPUTERS. DRAWN BY: JSS 13 PROVIDE TRANSLUCENT WINDOW FILM AT THIS RELITE. DATE ISSUED: 12.14.15 SHEET: A201 LRS Architects, Inc. ® 2015 PERMIT SET 12.14.15 A 1. REFLECTED CEILING DEMOLITION PLAN SCALE., 1/8"= V-0" RCP GENERAL NOTES 1. REFER TO SHEET A100 FOR A COMPLETE LIST OF GENERAL NOTES. 2. ALL ELECTRICAL AND MECHANICAL WORK IS DESIGN BUILD - VERIFY EXISTING CONDITIONS AND REPORT ANY DISCREPANCIES TO ARCHITECT. 3. EXISTING CEILING CONFIGURATION TO REMAIN UNLESS OTHERWISE NOTED. 4. ADJUST EMERGENCY LIGHTING & SPRINKLERS AS REQUIRED BY CODE. I t I 8,-0s U c�'-9" • lillil I I I I0lilt, II I I • \ r V • A • r \ /n\ 1111111 Mo nl V • IL11IL"gillilil 00100m 1111111 r / rt — nl • • ❑ \r V r\ r\ • \r V • • /nr • r rl V n \v I n V n /r - ll Il I (I Il V • ii /n\ a II H r,MEN 1. REFLECTED CEILING DEMOLITION PLAN SCALE., 1/8"= V-0" RCP GENERAL NOTES 1. REFER TO SHEET A100 FOR A COMPLETE LIST OF GENERAL NOTES. 2. ALL ELECTRICAL AND MECHANICAL WORK IS DESIGN BUILD - VERIFY EXISTING CONDITIONS AND REPORT ANY DISCREPANCIES TO ARCHITECT. 3. EXISTING CEILING CONFIGURATION TO REMAIN UNLESS OTHERWISE NOTED. 4. ADJUST EMERGENCY LIGHTING & SPRINKLERS AS REQUIRED BY CODE. LEGEND 117 ARCH I T E C T S NEW GYPSUM BOARD FRAMED CEILING 720 NW Davis 503.221.1121 19 .� (SEE DETAIL 9/ A301 Suite 300 503 221.2077 D EXISTING 2X4 ACOUSTICAL SUSPENDED CEILING Portland OR 97209 www.Irsarchitecis.com ® EXISTING HVAC SUPPLY EXISTING HVAC RETURN vp EXISTING BUILDING STANDARD LIGHT FIXTURE OF MCHWUPM © PROVIDE NEW OR RELOCATED BUILDING e STANDARD 2x4 LIGHT FIXTURE r ® EGRESS PATH SHOWN FOR REFERENCE ONLY 6z (DESIGN -BUILD) - " 0 tv �e --%'' EXISTING 2x4 LIGHT FIXTURE TO BE REMOVED OR RELOCATED NEW PENDANT LIGHT FIXTURE CONSULTANT: NEW EXHAUST FAN • EXISTING SPRINKLER +8'-1 CEILING HEIGHT AFF 4 NEW VANITY LIGHT FIXTURE MFR: YLIGHTING MODEL: LATITUDE 5652 BATH BAR 0 (3+ EXIT SIGNS (W/ INTEGRAL ARROW WHERE OCCURS) 2. REFLECTED CEILING PLAN PROJECT NUMBER: 215216 SCALE: 1/8"= 1' -Cl" Express Employment RCP GENERAL NOTES Professionals T.I. 1. REFER TO SHEET A100 FOR A COMPLETE LIST OF GENERAL NOTES. Nimbus Center 2. ALL ELECTRICAL WORK IS DESIGN BUILD - EXISTING & NEW LIGHT FIXTURES SHOWN FOR 10115 SW Nimbus Avenue REFERENCE ONLY. VERIFY EXISTING CONDITIONS AND REPORT ANY DISCREPANCIES TO ARCHITECT. SUBMIT ELECTRICAL PLANS TO ARCHITECT FOR REVIEW PRIOR TO Suite 500 COMPLETION. CLEAN & RESTORE ALL LIGHTS TO WORKING ORDER PRIOR TO JOB Tigard, OR 97223 3. ALL MECHANICAL WORK IS DESIGN BUILD - EXISTING & NEW DIFFUSERS SHOWN FOR REFERENCE ONLY. VERIFY EXISTING CONDITIONS AND REPORT ANY DISCREPANCIES TO ARCHITECT. SUBMIT MECHANICAL PLANS TO ARCHITECT FOR REVIEW PRIOR TO CONSTRUCTION. CLEAN ALL DIFFUSERS PRIOR TO JOB COMPLETION. EACH ENCLOSED ROOM TO HAVE ONE (1) HVAC SUPPLY AND ONE (1) HVAC RETURN UNLESS OTHERWISE NOTED. 4. SUBMIT PROPOSED LOCATIONS FOR EMERGENCY LIGHTING & SPRINKLERS TO ARCHITECT FOR REVIEW AND COORDINATION PRIOR TO CONSTRUCTION, 5. REPLACE ALL DAMAGED CEILING TILES & GRID TO MATCH EXISTING BUILDING STANDARD. 6. WHERE NEW LIGHTS ARE ADDED - MATCH EXISTING BUILDING STANDARD TYPE AND FINISH. ADJUST LIGHT FIXTURES AS NEEDED PER NEW LAYOUT. RCP KEYNOTES 1 PROVIDE AND INSTALL THREE (3) BRUCK, RAINBOW 1 DOWN PENDANTS, 4" CANOPY, SUNSET, MATTE CHROME AT 6'-6" AFF AT RECEPTION DESK. 2 PROVIDE NEW FRAMED GYPSUM BOARD CEILING TO MATCH EXISTING WITH NEW VANITY LIGHT FIXTURE AND EXHAUST FAN. PROVIDE NEW, MORE POWERFUL, EXHAUST FAN AT SERVER. 4 PROVIDE LED EXIT SIGN. SHEET TITLE: Reflected Ceiling Demolition Plan & RCP DRAWN BY: JSS DATE ISSUED: 12.14.15 SHEET: A202 LRS Archkexs, Inc. ® 2015 PERMIT SET 12.14.15 NONE lillil I0lilt, I 1111111 Mo nl IL11IL"gillilil 00100m 1111111 LEGEND 117 ARCH I T E C T S NEW GYPSUM BOARD FRAMED CEILING 720 NW Davis 503.221.1121 19 .� (SEE DETAIL 9/ A301 Suite 300 503 221.2077 D EXISTING 2X4 ACOUSTICAL SUSPENDED CEILING Portland OR 97209 www.Irsarchitecis.com ® EXISTING HVAC SUPPLY EXISTING HVAC RETURN vp EXISTING BUILDING STANDARD LIGHT FIXTURE OF MCHWUPM © PROVIDE NEW OR RELOCATED BUILDING e STANDARD 2x4 LIGHT FIXTURE r ® EGRESS PATH SHOWN FOR REFERENCE ONLY 6z (DESIGN -BUILD) - " 0 tv �e --%'' EXISTING 2x4 LIGHT FIXTURE TO BE REMOVED OR RELOCATED NEW PENDANT LIGHT FIXTURE CONSULTANT: NEW EXHAUST FAN • EXISTING SPRINKLER +8'-1 CEILING HEIGHT AFF 4 NEW VANITY LIGHT FIXTURE MFR: YLIGHTING MODEL: LATITUDE 5652 BATH BAR 0 (3+ EXIT SIGNS (W/ INTEGRAL ARROW WHERE OCCURS) 2. REFLECTED CEILING PLAN PROJECT NUMBER: 215216 SCALE: 1/8"= 1' -Cl" Express Employment RCP GENERAL NOTES Professionals T.I. 1. REFER TO SHEET A100 FOR A COMPLETE LIST OF GENERAL NOTES. Nimbus Center 2. ALL ELECTRICAL WORK IS DESIGN BUILD - EXISTING & NEW LIGHT FIXTURES SHOWN FOR 10115 SW Nimbus Avenue REFERENCE ONLY. VERIFY EXISTING CONDITIONS AND REPORT ANY DISCREPANCIES TO ARCHITECT. SUBMIT ELECTRICAL PLANS TO ARCHITECT FOR REVIEW PRIOR TO Suite 500 COMPLETION. CLEAN & RESTORE ALL LIGHTS TO WORKING ORDER PRIOR TO JOB Tigard, OR 97223 3. ALL MECHANICAL WORK IS DESIGN BUILD - EXISTING & NEW DIFFUSERS SHOWN FOR REFERENCE ONLY. VERIFY EXISTING CONDITIONS AND REPORT ANY DISCREPANCIES TO ARCHITECT. SUBMIT MECHANICAL PLANS TO ARCHITECT FOR REVIEW PRIOR TO CONSTRUCTION. CLEAN ALL DIFFUSERS PRIOR TO JOB COMPLETION. EACH ENCLOSED ROOM TO HAVE ONE (1) HVAC SUPPLY AND ONE (1) HVAC RETURN UNLESS OTHERWISE NOTED. 4. SUBMIT PROPOSED LOCATIONS FOR EMERGENCY LIGHTING & SPRINKLERS TO ARCHITECT FOR REVIEW AND COORDINATION PRIOR TO CONSTRUCTION, 5. REPLACE ALL DAMAGED CEILING TILES & GRID TO MATCH EXISTING BUILDING STANDARD. 6. WHERE NEW LIGHTS ARE ADDED - MATCH EXISTING BUILDING STANDARD TYPE AND FINISH. ADJUST LIGHT FIXTURES AS NEEDED PER NEW LAYOUT. RCP KEYNOTES 1 PROVIDE AND INSTALL THREE (3) BRUCK, RAINBOW 1 DOWN PENDANTS, 4" CANOPY, SUNSET, MATTE CHROME AT 6'-6" AFF AT RECEPTION DESK. 2 PROVIDE NEW FRAMED GYPSUM BOARD CEILING TO MATCH EXISTING WITH NEW VANITY LIGHT FIXTURE AND EXHAUST FAN. PROVIDE NEW, MORE POWERFUL, EXHAUST FAN AT SERVER. 4 PROVIDE LED EXIT SIGN. SHEET TITLE: Reflected Ceiling Demolition Plan & RCP DRAWN BY: JSS DATE ISSUED: 12.14.15 SHEET: A202 LRS Archkexs, Inc. ® 2015 PERMIT SET 12.14.15 1. ENLARGED PLAN- RECEPTION/APPLICATIONS/F.O.C. SCALE: 114'= 1'-0" _ _.._.._.. a -1v I.V. 4 EQUAL CABINETS VERTICAL 5 A3fl2 8 C14 A3fl2 A3fl2 D PROVIDE VERTICAL GRAB BAR 4 GRAB BAR r — — _1 _ _ rmI F—'----- �—.� _.--� FILES FILES { :r (NIC) i (NIC) ICU G� VERTICAL SURFACES, PL - 4. F.O.G. 111 ELEVATIONS SCALE.' 114"= 1'-0" VERTICAL SURFACES, PL_ PROVIDE LOCKABLE HARDWARE RUBBER BASE, RB - 7. HALLWAY ELEVATION SCALE: 114" = f-0" FXI.CT1K1r'.1 nN ADA UN1S1s UNSEX 105 B > 5 v A A3fl 1 " N 2. ENLARGED PLAN - ADA UNISEX RESTROOM SCALE: 114"= 1'-0" 118" COVER PLATE HSS 3x3x1t8 FIAT. HEIGHT 35J8'x9'x318' " BASE PIWITH (2)318` C1fAMk . TiTEN HD SECnON a SECTION A EXISTING COLLUMN HORIZONTAL I SURFACES, PL - 314" STAINED HARDWOOD TO MATCH DOORS 1/4" PAINTED REVEAL, TYP CONTINUOUS TRACK WITH FASTENER TO TOP PLATE 1/8" STEEL 3-518' 25 GA. (362S125-18) MTL STUDS @ 24" O.C. WITH 518" GYP. BD. EACH SIDE PROVIDE 3x3x1/8 HSS TUBE STEEL SUPPORTS AT 48' O.C. INSIDE EXPOSED WALL ENDS TO FULL WALL HEIGHT AND MOUNT TO FLOOR WITH 318" PLATE STEEL. POWDER DRIVEN ANCHOR AT 2'-0' O.C. THRU MTL. STUD TRACK, UON BASE ON BOTH SIDES AS SPECIFIED EXISTING SLA 8. PARTIAL HEIGHT WALL w/ WOOD CAP SCALE.1'= ?'-0" OPEN .'6g VERTICAL L SURFACES, PL - RUBBER BASE, RB- r — END PANEL AT — EXTERIOR WINDOWS 3. APPLICATIONS 102 ELEVATIONS SCALE: 114"= V-0" VALL MOUNT LIGHT FIXTUR– MIRRC PLAM COUNTER WIT 4" BACKSPLASH (PL ADA COMPLIANT SIN AND FAUCET; PROVIE HEAT WRAP AT AI EXPOSED PIPES; BRACE AS NEEDED VERTICAL SURFACES, PL - AL i, PL- RB - 3'-0" 4`-2" Z-51/4" VERTICAL 5 _ 8 C14 A3fl2 A3fl2 D 314" STAINED HARDWOOD TO MATCH DOORS 1/4" PAINTED REVEAL, TYP CONTINUOUS TRACK WITH FASTENER TO TOP PLATE 1/8" STEEL 3-518' 25 GA. (362S125-18) MTL STUDS @ 24" O.C. WITH 518" GYP. BD. EACH SIDE PROVIDE 3x3x1/8 HSS TUBE STEEL SUPPORTS AT 48' O.C. INSIDE EXPOSED WALL ENDS TO FULL WALL HEIGHT AND MOUNT TO FLOOR WITH 318" PLATE STEEL. POWDER DRIVEN ANCHOR AT 2'-0' O.C. THRU MTL. STUD TRACK, UON BASE ON BOTH SIDES AS SPECIFIED EXISTING SLA 8. PARTIAL HEIGHT WALL w/ WOOD CAP SCALE.1'= ?'-0" OPEN .'6g VERTICAL L SURFACES, PL - RUBBER BASE, RB- r — END PANEL AT — EXTERIOR WINDOWS 3. APPLICATIONS 102 ELEVATIONS SCALE: 114"= V-0" VALL MOUNT LIGHT FIXTUR– MIRRC PLAM COUNTER WIT 4" BACKSPLASH (PL ADA COMPLIANT SIN AND FAUCET; PROVIE HEAT WRAP AT AI EXPOSED PIPES; BRACE AS NEEDED VERTICAL SURFACES, PL - AL i, PL- RB - 3'-0" 4`-2" Z-51/4" 5. ADA UNISEX RESTROOM 105 ELEVATIONS 6. BREAKROOM 108 ELEVATION SCALE: 114'= 1'-0" SCALE: 114"= 1'-0" 3 518" 20 GA (362S162-33)— JOISTS @ 24" MIN. O.C. 518" GYP. BD. SCREWED TO JOIST BOTTOM FLANGE 1/4' MW. PENETRATION 9. FRAMED CEILING DETAIL SCALE., NOT TO SCALE 11/2- 16 GA (150U50-54) U -CHANNEL BRIDGING @ MIDSPAN NO A NO BACK - ACCESS TO ELECTRICAL PLUGS T.O. FIN_FLR CPU (NIC) i I — CLEAR SILICONE CAULK AT SEAM (TYP) — PLASTIC LAMINATE COUNTERTOP & SPLASH AT ALL EXPOSED SURFACES & EDGES (SEE ELEVATION) OVER 314- SUBSTRATE N r MAGNETIC PUSH TO OPEN HARDWARE WITH LOCK (TYP) 4" DIA. PLASTIC AIR VENT GROMMET CAP, 4 TOTAL PER CABINET - 2 EACH SIDE, VERIFY COLOR (DOUG MOCKET 2GAVG2 OR SIM.) PLASTIC LAMINATE AT ALL SEMI -EXPOSED SURFACES OVER 3/4" SUBSTRATE; SELF EDGE WHITE INTERIOR w/ ADJUSTABLE SHELVES (TYP) BASE AS SPECIFIED (TYP) 10. LOWER CABINET WJ DOOR SCALE: 1 " = !'-V" NOTE COORDINATE WITH ELECTRICIAN - OUTLETS TO BE BEHIND CABINETS ARCHITECTS 720 NW DaVis 503.221.1121 19 Suite 300 503 221.2077 d Portland OR 97209 www1sarchitecksmin CONSULTANT: PROJECT NUMBER: 215216 Express Employment Professionals T.I. Nimbus Center 10115 SW Nimbus Avenue Suite 500 Tigard, OR 97223 SHEET TITLE: Enlarged Plans, Interior Elevations & Details EMMMMI DRAWN BY: JSS DATE ISSUED: 12.14.15 SHEET: PERM/ T SET 92.14.95 VERTICAL 5 _ 8 SURFACES, A3fl2 A3fl2 PL -1 PROVIDE VERTICAL GRAB BAR GRAB BAR r — — _1 _ _ rmI \ix TOILET PAPER ICU DISPENSER I TOILET SEAT I COVER DISPENSER ( REF PLASTIC r (NIC) " LAMINATE WAINSCOTING ON ALL WALLS, TYP. (PL-) 7 8 RUBBER BASE, 2 A302 HORIZONTAL SURFACES, PL- RB- 1'-4" T-0" 2'-3" RUBBER BASE, RB - 5. ADA UNISEX RESTROOM 105 ELEVATIONS 6. BREAKROOM 108 ELEVATION SCALE: 114'= 1'-0" SCALE: 114"= 1'-0" 3 518" 20 GA (362S162-33)— JOISTS @ 24" MIN. O.C. 518" GYP. BD. SCREWED TO JOIST BOTTOM FLANGE 1/4' MW. PENETRATION 9. FRAMED CEILING DETAIL SCALE., NOT TO SCALE 11/2- 16 GA (150U50-54) U -CHANNEL BRIDGING @ MIDSPAN NO A NO BACK - ACCESS TO ELECTRICAL PLUGS T.O. FIN_FLR CPU (NIC) i I — CLEAR SILICONE CAULK AT SEAM (TYP) — PLASTIC LAMINATE COUNTERTOP & SPLASH AT ALL EXPOSED SURFACES & EDGES (SEE ELEVATION) OVER 314- SUBSTRATE N r MAGNETIC PUSH TO OPEN HARDWARE WITH LOCK (TYP) 4" DIA. PLASTIC AIR VENT GROMMET CAP, 4 TOTAL PER CABINET - 2 EACH SIDE, VERIFY COLOR (DOUG MOCKET 2GAVG2 OR SIM.) PLASTIC LAMINATE AT ALL SEMI -EXPOSED SURFACES OVER 3/4" SUBSTRATE; SELF EDGE WHITE INTERIOR w/ ADJUSTABLE SHELVES (TYP) BASE AS SPECIFIED (TYP) 10. LOWER CABINET WJ DOOR SCALE: 1 " = !'-V" NOTE COORDINATE WITH ELECTRICIAN - OUTLETS TO BE BEHIND CABINETS ARCHITECTS 720 NW DaVis 503.221.1121 19 Suite 300 503 221.2077 d Portland OR 97209 www1sarchitecksmin CONSULTANT: PROJECT NUMBER: 215216 Express Employment Professionals T.I. Nimbus Center 10115 SW Nimbus Avenue Suite 500 Tigard, OR 97223 SHEET TITLE: Enlarged Plans, Interior Elevations & Details EMMMMI DRAWN BY: JSS DATE ISSUED: 12.14.15 SHEET: PERM/ T SET 92.14.95 PROVIDE (2) #8 SHEET METAL SCREWS AT EA. BRACE ATTACHMENT TO STRUCTURAL MEMBER TYP. PROVIDE 2' X 1/8' LIGHT & SOUND SEALING GASKET CONTINUOUS BETWEEN WALL & CEILING PROVIDE (2) FASTENERS @ EA BRACE STUD CONNECTION TO TOF OF WALL STU[ 3-518' 25 GA (362S125-18) MTL STUDS @ 24" O.C. WITH 518" GYP. BD. EACH SIDE. PROVIDE 3' SOUND ATTENUATION BATT INSULATION FRICTION FIT IN STUD SPACE AND ACOUSTIC SEALANT @ CEILING GRID. BASE ON BOTH SIDES AS SPECIFIED 1, BUILDING STANDARD PARTITION SCALE: 112'= 1-0 5. TYPICAL UPPER CABINET SCALE: 1" =1'-0" 20 GA. 3 5/8' STUD BRACING TO STRUCTURE @ 8'-0" O.C. VERIFY HEIGHT 'OWDER DRIVEN ANCHOR iT 2'-0' Q.C. THRU MTL. STUD TRACK, UON -- EXISTING SLAB 2. TALL CABINET SCALE. 112" = 1'--O' CONTINUOUS FRENCH CLEAT PLASTIC LAMINATE AT ALL EXPOSED SURFACES & EDGES (SEE ELEVATION) OVER 3/4" SUBSTRATE; SELF EDGE 4' WIRE PULLS, BRUSHED ALUMINUM (TYP) WHITE INTERIOR w/ ADJUSTABLE SHELVES (TYP) BASE AS SPECIFIED (TYP) PLASTIC LAMINATE AT ALL EXPOSED & SEMI -EXPOSED wo i -1, + PLASTIC LAMINATE AT ALL EXPOSED & I SEMI -EXPOSED SURFACES OVER 314" SUBSTRATE; SELF EDGE SURFACES OVER 3/4' TEMP O SUBSTRATE; SELF LL WHITE INTERIOR w/ EDGE ADJUSTABLE SHELVES (TYP) p • WHITE INTERIOR (TYP) WHITE INTERIOR w1 TEMP 4- WIRE PULLS, BRUSHED I P ADJUSTABLE -`� ALUMINUM (TYP) SHELVES (TYP) Uj ADA COMPLIANT SINK TO �-- -- PLASTIC LAMINATE AT ALL EXPOSED & z t>= SEMI -EXPOSED SURFACES OVER 314" BE INSTALLED w/ CLEAR MICROWAVE ! SUBSTRATE; SELF EDGE 4' WIRE PULLS, (NIC) # BRUSHED CAULK AT ALL SEAMS OPEN TO WALL; NO BACK ALUMINUM (TYP) N _j -.-�-- VERIFY SIZE OF MICROWAVE WITH TENANT � U_ C PRIOR TO CONSTRUCTION 1'-6" 1-112" THICK MICROWAVE SHELF ADA COMPLIANT MIRROR PLASTIC LAMINATE COUNTERTOP & 2,-0R SPLASH AT ALL EXPOSED SURFACES & EDGES (SEE ELEVATION) OVER 314 - MEDIUM -DENSITY FIBERBOARD I ff MADE W/ EXTERIOR GLUE. BLOCKING AS REQUIRED 2X4 LEDGER BACK & wo i -1, 'I -V TEMP O LL a - SIDES p 0 o TEMP 11 1 Uj ADA COMPLIANT SINK TO z z t>= z z BE INSTALLED w/ CLEAR O . p M � CAULK AT ALL SEAMS N _j � U_ C CONTINUOUS STEEL ANGLE SUPPORT 1'-1" 11" HEAT PROOF WRAP @ -- EXPOSED PIPING 9. SECTION THRU VANITY SCALE: 1" = 1'-0' C :[P. FIN. FLR 6. MICROWAVE CABINET SECTION SCALE' 1"= V-0" I T-0 �341-04� i ` TEMP M 0 F L A FLUSH PANEL FLUSH w/ LOUVER ALUMINUM FRAMED GLASS DOOR NOTES: 1. DOORS 105, 106, AND 108 TO BE SOLID WOOD TYPE F UNLESS OTHERWISE NOTED AND STAINED TO MATCH EXISTING (SOLID CORE ROTARY SLICED BIRCH WITH A CLEAR FINISH - FIELD VERIFY). REUSE EXISTING DOORS IF POSSIBLE. 2. PROVIDE NEW ADA LEVER STYLE DOOR HARDWARE (SCHLAGE AL SERIES SATURN IN 626 BRUSHED CHROME FINISH) AS NEEDED. REPLACE ALL ORB STYLE DOOR KNOBS. 3. PROVIDE LOCKS ON DOORS 107,109 AND 110. 4. PROVIDE OCCUPANCY INDICATORS ON DOORS 105 AND 1€ 6. 5. DOOR 107 TO BE TYPE L. 6. DOORS 101,103,109 AND 110 TO BE TYPE A - CASCADE NARROW STYLE DOOR WITH 10' BOTTOM RAIL (OR SIMILAR) 1& DOOR TYPES SCALE: 114" = 1'-0" PLASTIC LAMINATE AT ALL EXPOSED SURFACES & EDGES (SEE ELEVATION) OVER 3/4' SUBSTRATE 11/40 3-0/8" 20 GA. MTL STUDS @ 24" O.C. WITH 5/8' GYP. BD. EACH SIDE; PROVIDE PAINT 1 2" GROMMET; 2 MIN. LOCATIONS TBD IN FIELD STEEL ANGLE SUPPORT AS REQ'D; PAINT ANY EXPOSEI BRACKET TO MATCH WALL COLOR BASE AS SPECIFIED; REFEF / TO ELEVATION OtT.O. FIN. FLR 3. RECEPTION DESK SCALE: 1 " = 1-0" n CLEAR SILICONE CAULK AT SEAM (TYP) PLASTIC LAMINATE COUNTERTOP & SPLASH AT ALL EXPOSED SURFACES & EDGES (SEE ELEVATION) OVER 3/4' SUBSTRATE R 6" DRAWER 4" WIRE PULLS, BRUSHED ALUMINUM (TYP) PLASTIC LAMINATE AT ALL SEMI -EXPOSED SURFACES OVER 3/4" SUBSTRATE; SELF EDGE WHITE INTERIOR w/ ADJUSTABLE SHELVES (TYP) BASE AS SPECIFIED; REFER TO ELEVATION 2" GROMMET - (5) LOCATIONS TO BE DETERMINED IN FIELD PLASTIC LAMINATE COUNTERTOP AT ALL EXPOSED SURFACES & EDGES (SEE ELEVATION) OVER 314' SUBSTRATE STAINLESS STEEL WORKSURFACE SUPPORT AS REQUIRED CASEWORK SEEN BEYOND BASE AS SPECIFIED (TYP) 4. CASEWORK AT APPLICATIONS SCALE. I" BLACK HEAT PROOF WRAP @ EXPOSED PIPING n CLEAR SILICONE CAULK AT SEAM (TYP) CHROME ACCESSIBLE GOOSENECK FAUCET ADA COMPLIANT STAINLESS STEEL KITCHEN SINK PLASTIC LAMINATE COUNTERTOP & SPLASH AT ALL EXPOSED SURFACES & EDGES (SEE ELEVATION) OVER 314" MEDIUWDENSITY FIBERBOARD MADE W/ EXTERIOR GLUE. 4" WIRE PULLS, BRUSHED ALUMINUM PLASTIC LAMINATE OVER 314" SUBSTRATE REMOVABLE BASE CABINET DOORS W/ FULLY CONCEALED EUROPEAN HINGE & QUICK SNAP OFF CAPABILITY WHITE INTERIOR (TYP) T.O. FIN. FLR IFI VT .I T.O. FIN. FLR - CONTINUE FLOOR FINISH UNDER CABINET AT SINK, SEE FLOOR PLAN 7. LOWER CABINET W/ DRAWER & DOOR 8. TYPICAL LOWER CABINET w/ SINK SCALE: 1" =1'-0" SCALE.- i" = 14" r (:K) SINGLE OPENING SINGLE OPENING w/ 374" a SINGLE OPENING w/ 2'-0' ® SINGLE OPENING TWO (2) RELITES SINGLE OPENING THREE (3) RELITES WIDE RELITE WIDE RELITE NOTES: 1. ALL FRAMES TO BE BUILDING STANDARD KNOCKDOWN (BLACK -VERIFY) UNLESS OTHERWISE NOTED. 2. FRAMES 101,103,109 AND 110 TO BE CASCADE 450 CS CENTER PLANE NON THERMAL STOREFRONT, 2" x 4FOR 8' GLAZING. FINISH: CLEAR ANODIZED (OR SIMILAR). 3. PROVIDE TEMPERED GLASS AT ALL RELITES UNLESS OTHERWISE NOTED. it J -3v wo i -1, 'I -V TEMP r (:K) SINGLE OPENING SINGLE OPENING w/ 374" a SINGLE OPENING w/ 2'-0' ® SINGLE OPENING TWO (2) RELITES SINGLE OPENING THREE (3) RELITES WIDE RELITE WIDE RELITE NOTES: 1. ALL FRAMES TO BE BUILDING STANDARD KNOCKDOWN (BLACK -VERIFY) UNLESS OTHERWISE NOTED. 2. FRAMES 101,103,109 AND 110 TO BE CASCADE 450 CS CENTER PLANE NON THERMAL STOREFRONT, 2" x 4FOR 8' GLAZING. FINISH: CLEAR ANODIZED (OR SIMILAR). 3. PROVIDE TEMPERED GLASS AT ALL RELITES UNLESS OTHERWISE NOTED. it J -3v wo i -1, 'I -V R iL- TEMP TEMP 11 1 •►-uwt TEMP I I TEMPTEMP 11 1 11. DOOR FRAMES & RELITE TYPES SCALE: 114" = 1' O" �� 8'x 4' FRAMED RELITE ARCH ITECT: 720 NW Davis 503.221.1121 IR Suite 300 503 221.2077 D Portland OR 97209 www.irsa.mhftects.com CONSULTANT: PROJECT NUMBER: 215216 Express Employment Professionals T.I. Nimbus Center 10115 SW Nimbus Avenue Suite 500 Tigard, OR 97223 SHEET TITLE: Interior Details & Door Schedule DRAWN BY: JSS DATE ISSUED: 12.14.15 SHEET: LRS Amhiteds Inc. � 2015 PERMIT SET � 2.14.?' 5