Loading...
Plans (3) BUP2015 - 00054 ------ 0100 00 GENERAL DATA 9. AT FRP,PLASTIC LAMINATE,ETC.,WAINSCOT PANELING INSTALL WATER-RESISTANT GYPSUM BOARD. e. THERMOSTAT LOCATIONS AND ZONE/UNIT ASSOCIATED THEREWITH ` GENERAL REQUIREMENTS 10.TRIM ACCESSORIES SHALL COMPLYWITH ASTM G1047, C ANY SUPPLEMENTAL EXHAUST FANS OR SPECIAL SYSTEMS 1. ALL CONSTRUCTION WORK SHALL BE DONE IN COMPLIANCE WITH THE LATEST EDITION OFTHE OREGON 11.USE GEORGIA PACIFIC DENSGLAS GOLD ON EXTERIOR FACE OF EXTERIOR WALLS AND COAT WITH STO FiNISH g. ZONE DIAGRAM TENANT IMPROVEMENT for � 3a8� STRUCTURAL SPECIALTY CODE,AN D ALL OTHER STATE OR LOCAL CODE REQUIREMENTS THATAPPLY. SYSTEM. HVAC DESIGN STANDARDS 2. VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON DRAWINGS AND AT THE EXISTING BUILDING AND WALL CONSTRUC71ON EXECUTION THE FOLLOWING ARE MINIMUM DESIGN STANDARDS: MARTIN W. HANSON NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO STARTING THE WORK 1. FASTEN FRAMING MEMBERS TOGETHER BY WELDING OR BY USING SELF-DRILLING OR SELF TAPPING 1. 350 SQUARE FOOT PER TON. 3. CONTRACTOR AND ALL SUBCONTRACTORS SHALL PERFORM DUE DILIGENCE INSPECTION OF ALL EXISTING SCREWS. WELDING SHALL CONFORM TO AWS D13 WELDING PROCEDURE. ELECTRODES AND SCREW Z�t CONDITIONS PRiOR TO SUBMITTAL OF A PROPOSAL.SUBMITTAL OFA PROPOSAL SHALL BE CONSIDERED CONNECTIONS SHALL BE AS REQUIRED AND INDICATED IN THE DESIGN CALCULATIONS. DO NOT FIELD WELD 2. ADDRESS LOADS BY SPECIFIC LOCATION AND USE AS WELL AS CRITERIA PROVIDED TO PACTRUST BYCLA KAM S, OREGON �'/� CONFIRMATION THAT SUCH INSPECTION HAS BEEN MADE,AND NO FURTHER COMPENSATION SHALL BE DUE MATERIALS LIGHTER THAN 18 GA. TENANT PRIOR TO CONSTRUCTION: RECEIVED REAL ASSET PORTFOLIO v'�''�' C� THE CONTRACTOR FOR CLAIMS ARISING AS A RESULT OF FAILURE TO PERFORM SUCH INSPECTION. 2. PROVIDE ACCURATELY ALIGNED RUNNERS AT TOP AND BOTTOM OF PARTITIONS. ANCHOR TRACKS AS a. EXTERIOR EXPOSURE AREAS 4. BY SUBMITTING A PROPOSAL,CONTRACTOR AND ALL SUBCONTRACTORS CERTIFY THAT THEY HAVE INDICATED IN THE DESIGN CALCULATIONS. BUTT WELD JOINTS IN TRACKS OR SPLICE WITH STUD INSERTS. b. INTERIOR AREAS,SIZE AND USE f EXAMINED THE SITE AND INCLUDED IN THEIR PROPOSAL ALL WORK NECESSARY TO COMPLETE THE WORK FASTENERS SHALL BE AT LEAST 3 INCHES FROM THE EDGE OF CONCRETE SLABS. MAR O 5 2015 OF O� DESCRIBED OR REASONABLY IMPLIED IN THESE DOCUMENTS. THIS INCLUDES BUT MAY NOT BE LIMITED TO 3. CUT STUDS SQUARE AND SET WITH FIRM BEARING AGAINST WEBS OFTOPAND BOTTOM TRACKS. POSITION c. CONFERENCE/TRAINING ROOMS MANAGEMENT LLC ALL MATERIALS AND INSTALLATION,DISPOSAL OF EXCESS MATERIALS(USEABLE FINISH MATERIALS SHALL BE STUDS VER71CALLY IN TRACKS AND SPACE AS INDICATED IN DESIGN. DO NOT SPLICE STUDS. PROVIDE AT d. COMPUTER/SERVER AND TELEPHONE ROOMS TO HAVE PROVISION FOR LOW AMBIENT OPERATION LEFT IN THE TENANT SPACE AS DIRECTED BY PACTRUST),CLEANING AND ALLPREPARATION OF SUBSTRATE LEAST TWO FULL HEIGHT KING STUDS AT DOORS AND OTHER OPENINGS 2 FEET WIDE OR LARGER. PROVIDE AND 24-HOUR USE. CIN OF TiGARD SURFACES PRIOR TO INSTALLATION,AS WELLAS FINAL CLEAN UP. JACK STUDS OVER OPENINGS,AS NECESSARY,TO MAINTAIN INDICATED STUD SPACING. PROVIDE TRIPLE 3. SYSTEM DESIGN CRITERIA-SIZE ZONES FOR 3-5TON UNITS BASED ON USE&EXPOSURE CRITERIA. p�NING�tNGINEERING PROJECT 5 160 5. IT iS THE INTENT OF THESE CONTRACT DOCUMENTS TO MATCH AND MAINTAIN EXISTING BUILDING STUDS AT CORNERS,POSITIONED TO RECEIVE INTERIOR AND EXTERIOR FINISHES. FASTEN STUDS AT TOP PACKAGED OR SPLIT SYSTEM EQUIPMENT GREATER THAN 5TONS SHALL BE SPLIT INTO MULTIPLE ZONES. STANDARDS FOR ALL EXISTING PRODUCTS AND SYSTEMS. UPON DISCOVERY OF A DISCREPANCY TO THIS AND BOTTOM TRACKS BY WELDING OR SCREWING BOTH FLANGES TOTHE TRACKS. VAV OR WATER SOURCE HEAT PUMP SYSTEMS GREATER THAN 3 TONS SHALL BE SPLiT INTO MULTIPLE INTENSION,THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY. 4. INSTALL ALL INTERIOR AND EXTERIOR GYPSUM BOARD PRODUCTS AND ACCESSORIES AS REQUIRED FOR ZONES. PROJECT NA RRATIV E 6. FURNISH ALL NEW MATERIALS EXCEPT WHERE SPECIFICALLY NOTED OTHERWISE. THE PROJECT. 4. ALL ENCLOSED ROOMS OR OFFICES TO HAVE DUCTED SUPPLY&RETURN GRILLES. CITY OF TIG PROJECT CONSISTS OF REMODEL WORK TO 1,857 SF OF EXISTING OFFICE SPACE. WORK 7. COORDINATE THE WORK OF ALL TRADES. PROVIDE CARPET"WALK-OFF MATS"TO PROTECT EXISTING 5. COMPLY WITH USG GYPSUM CONSTRUCTION HANDBOOK AND MANUFACTURER'S RECOMMENDATIONS. 5. VACANT SPACE SHALL HAVE DEDICATED GAS SERVICE FOR FUTURE BUILD-OUT OR FREEZE PROTECTION. �L ARD SHALL INCLUDE BUT NOT BE LIMITED TO DRYWALL/METAL STUDS,SUSPENDED CEILINGS, w CARPETS. 6. FINISH QUALITY: 6. UNITS: LENNOX,TRANE,YORK OR CARRIER-71/2 TON MAXIMUM UNIT SIZE. ANY UNIT IN EXCESS OF 712 Approved by Planning DOORS/FRAMES AND PAINTING. ALL WORK TO MEET ADA REQUIREMENTS. H 8. KEEP THE AREA OF WORK FREE OF GARBAGE AND DEBRIS ON A DAILY BASIS INCLUDING DOCK ACCESS AREA PROCESS TRADE NOMENCLATURE TONS SHALL HAVE SPECIAL APPROVAL BY BUILDING OWNER. AREAS AND COMMON AREA. FLOORS TO BE SWEPT OR VACUUMED DAILY. Date: -9/S j OFFICE/OTHER AREAS TAPE/2a FiNISH COATS'! SMOOTH FINISH TAPED 7. HVAC UNITS WITH EQUAL TO OR GREATER THAN 5-TONS TO HAVE DUCT SMOKE DETECTORS AND BE15 MM��11 9. PROVIDE ADEQUATE PROTECTION TO ALL EXISTING IMPROVEMENTS INCLUDING BUT NOT LIMITED TO CONNECTED TO A MONITORING STATION WITHIN THE BUILDING. COMMON CORRIDORS AND STAIRS,BUILDING ENTRANCES,SUITE ENTRANCES,ETC. THE CONTRACTOR WILL USG*FIRST COAT' 'SAND AFTER TAPE/FINISH COAT(S) Initials: h'I(3 WORK INCLUDED BUT PERFORMED UNDER SEP. PERMIT BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGES TO EXISTING IMPROVEMENTS DUE TO CONSTRUCTION 7, FINISH EXPOSED INTERIOR GYPSUM BOARD WALLS AND CEILINGS SMOOTH STRAIGHT READY FOR FINISH AS 8. ECONOMIZER TO MEET CODE AND AS FOLLOWS: ACTIVITIES. SHOWN ON PLANS. 9 a. 6 TONS AND ABOVE MUST HAVE ECONOMIZER. PLUMBING 10.PROVIDE TEMPORARY SANITARY FACILITIES. CONSTRUCTION WORKERS SHALL NOT USE BUILDING 09 53 00 SUSPENDED ACOUSTICAL CEILING b. BAROMETRIC RELIEF ON 5-712 TON UNITS. RESTROOM FACILITIES. 1. IN EXISTING SPACES REPLACE WATER STAINED OR DAMAGED TILES. c. 8 TONS AND ABOVE MUST HAVE POWER EXHAUST. FIRE PROTECTION SPRINKLERWG 11.STORAGE AND STAGING OF CONSTRUCTION MATERIALS SHALL BE UNITED TO AREAS AS DESIGNATED AT PRE-CONSTRUCTION MEETING. UNDER NO CIRCUMSTANCES SHALL BUILDING UTILITY AREAS OR ANY OTHER 2. TUNE UP GRiD SYSTEM TO WITHIN PLUS OR MINUS 0.5 INCHES OF LEVEL d. t 12 THRU 4-TON OSA INTAKE WITH DAMPER. COMMON BUILDING AREA BE USED FOR STORAGE. 3. BENT OR DAMAGED T-BARS TO BE REPLACED. 15.ALL UNITS TO MEET OR EXCEED CURRENT ENERGY EFFICIENCY CODE REQUIREMENTS. I HEATING,VENTILATION&AiR CONDITIONING WORK 0 rA en 12.KEEP THE ROOF FREE OF DEBRIS(I.E.NAILS,SCREWS,BOTTLES,ETC.)AT ALL TIMES. 4. REPAIR HOLES IN GRID FROM REMOVED WALLS. USE OFARMSTRONG"BP ES-4 EXPANSION SLEEVE 16.DISTRIBUTION DUCTWORK i ELECTRICAL WORK, BOTH LINE VOLTAGE AND LOW VOLTAGE 13.ALL DIMENSIONS ARE TO FACE OF GYPSUM BOARD UNLESS OTHERWISE NOTED. ACCEPTABLE. a. SPIRAL ONLY IF EXPOSED. 14.CONFIRM SIZES OF ALL OPENINGS REQUIRED FOR THE INSTALLATION OF STRUCTURAL,MECHANICAL, 09 65 19 RESILIENT FLOORING-VINYL COMPOSITION TILE b. 26 GAUGE OR TO SMACNA STANDARDS IF PIPE IS CONCEALED ABOVE DROP OR HARD CEILING. ELECTRICAL AND PLUMBING WORK PRIOR TO FRAMING OR CUTTING FOR INSTALLATION. 1. EXTEND FINISH FLOORING UNDER CASEWORK. c. WRAP CONCEALED SUPPLY DUCTWORK IN NON-CONDITIONED AND SEMI-CONDITIONED SPACE WITH r� R �a p 15.LEAVE THE PROJECT CLEAN AND READY FOR OCCUPANCY. ' BUILDING INFORMATION TENANT INFOI�;MATION , a1N 2. INSTALL TILES IN QUARTER TURN PATTERN. MINIMUM R4.21NSULATION WITH FSK BARRIER. 16.CLEAN ADJACENT EXTERIOR AREA,I.E.WALKS,EXTERIOR GLASS,ETC. 09 9123 PAINTING d. HANGERS 12 GAUGE WIRE OR 18-GAUGE 1"WIDE STRAP. EXPOSED DUCT MUST HAVE ALLTHREAD OWNER: PACIFIC REALTY ASSOCIATES,L.P. TENANT: 4 ON t- ITFILL ALC PAPER AND SOAP DISPENSERS IN BREAK AREA. HANGERS AND FULL DIAMETER STRAP UP TO 18"0. LARGER THAN 18"MUST HAVE SADDLE TYPE Q INTERIOR: CLAMP. 15350 SW SEQUOIA PKWY#300 REAL ASSET PORTFOLIO MANAGEMENT LLC �14 C)r„ 18.PROVIDE"AS-BUILT"DRAWINGS OF THE WORKAT THE CONCLUSION OF CONSTRUCTION."AS-BUILT' 1. WALLS; e. BRANCH DUCTS SHALL BE PLUMB AND SQUARE{NO OCTOPUS). TEES SHALL BE MAXEMUM OF45 PORTLAND,ORE 97224 4 cn DRAWINGS MAY BE iN THE FORM OF TWO COPIES OF CONSTRUCTION DOCUMENTS MARKED-UP WITH RED cO ^ PEN.DELIVER RECORD DRAWINGS TO THE ARCHITECT. COMPLETE OPERATION AND MAINTENANCE MANUALS a. PRIME NEW DRYWALL WITH MILLER'S HIGH-BUILD"SUPER SEAL"PRIMER. DEGREES. OCCUPANCY_ $ SHALL BE PROVIDED FOR ALL MECHANICAL,ELECTRICAL AND PLUMBING EQUIPMENT.PACTRUST MAY HOLD L EACH BRANCH DUCT TO HAVE BALANCE DAMPER IN Y BRANCH. 503 624-6300 PHONE EI VND� b. NEW AND EXISTING DRYWALL TO 8E FINISHED TO ACHIEVE UNIFORM COVERAGE WITH M[LLER'S 6200 OR { � (PHONE) CONTRACTOR'S FINAL PAYMENT UNTIL"AS-BUILT"DRAWINGS AND O&M MANUALS HAVE BEEN RECEIVED 4480 WITH A TiGHT ROLLER STIPPLE FINISH. RESTROOM FINISHES TO BE MILLER'S S/G LATEX ENAMEL AND APPROVED. g. ALL DISTRIBUTION DUCT WORK TO BE INSTALLED MIN.24"ABOVE FINISH CEILING. {503}6247755(FAX) FLOOR AREA 1,857 SF OFFICE a o 2. DOORS AND FRAMES: 18.FLEX DUCT WILL BE NO LONGER THAN 6 FROM RIGID DUCT DOWN TO DIFFUSER. 19.1T IS THE INTENT OF THE CONTRACT DOCUMENTS THAT THE CONTRACTOR PROVIDE A COMPLETE, FUNCTIONING PROJECT INCLUDING ALL GENERAL,MECHANICAL AND ELECTRICAL CONSTRUCTION REQUIRED a. NEW HOLLOW METAL-PRIME,SAND,AND FINISH WiTH TWO COATS OF SEMI-GLOSS OIL BLDG.#. PCC BLDG. 17(PCC241) 19.DEFFUSERS: t+') TO FULFILL THAT INTENT. ALL ITEMS REQUIRED SHALL BE FURNISHED AND INSTALLED,REGARDLESS OF v10 r�i + b. EXISTING HOLLOW METAL-SAND,FILL IMPERFECTIONS WITH RONDO,SAND AND PRIME PATCHES WITH a. SUSPENDED CEILING SYSTEM(17-BAR) W PERFORATED FACE ADJUSTABLE CURVED BLADES-DESIGN .-i p.� 04 WHETHER OR NOT SHOWN ON THE DRAWINGS. ALKYD PRIMER,AND FINISH WITH SEMI-GLOSS OIL ENAMEL TITUS PCS SUPPLY AND T7TUS PAR RETURN OR APPROVED EQUAL CONST.TYPE.. Ii-B 20.ITEMS OR WORK NOT TO BE FURNISHED OR ACCOMPLISHED BY CONTRACTOR ARE NOTED"N.I.0". c. NEW WOOD-PRiME WITH ALKYD OIL UNDER-COATER,SAND,FILL ALL FASTENING HOLES WiTH b. GYP.BD.CEILING;SUPPLY-CURVED BLADE W1 080 DESIGN TTR1S 250;RETURN-BAR TYPE-DESIGN 21'ALIGN'AS USED IN THESE DOCUMENTS,MEANS TO ALIGN THE FINISHED FACES OF ELEMENTS IN THE SAME PAINTER'S PUTTY,CAULK ALL CRACKS IN CASINGS AND BETWEEN JAMBS AND WALLS USING DAP LATEX TITUS 350;EXHAUST-METAL OR ALUMINUM-12'x 12"EGG CRATE DESIGN TiTUS 50F. THIS BUILDING HOUSES VARIOUS TENANTS INCLUDING THIS TENANT. THE EXISTING PLANE,EITHER IMMEDIATELY ADJACENT TO ONE ANOTHER OR ACROSS AN OPENING. CAULK,AND FINISH WITH SATIN OIL ENAMEL c. ALL SUPPLY REGISTERS TO HAVE MANUAL VOLUME DAMPERS LOCATED IN DUCT ATIOR NEAR CLOSEST BUILDING IS A THREE(3)STORY BUILDING OF 61,990 SF AND IS FULLY SPRINKLERED. 1� 22.DO NOT DISASSEMBLE SETS OF CONSTRUCTION DRAWINGS.DRAWINGS ARE INTERRELATED. d. EXISTING WOOD-PREP,REPAIR IMPERFECTIONS,PRIME AS REQUIRED,AND REPAINT WITH SATIN OiL WYE BRANCH. THERE IS FRONTAGE ON ALL FOUR SIDES OF AT LEAST 110 FEET. 23.SUBMIT SAMPLES OR DRAW DOWNS FOR ALL FINISHES REQUESTED TO THE ARCHITECT OF RECORD WITHIN ENAMEL. IF FINISH iS NOT PAINTED,TOUCH UP STAiN,SEAL AS REQUIRED,AND RE VARNISH WiTH SATIN d. VARNISHCLEAN OR REPLACE ALL SUPPLY AND RETURN AIR GRILLS AND THEIR HOUSINGS AT PROJECT . TWO WEEKS OF PROJECT AWARD.PRODUCTS INSTALLED WITHOUT APPROVED SAMPLES ARE SUBJECT TO COMPLETION. ALLOWABLE AREA REPLACEMENT AT CONTRACTOR COST. AN APPROVED SUBMITTAL DOES NOT CHANGE THE CONTRACTUAL 3. CEILINGS; 20.THERMOSTAT: ALL EXISTING MERCURY TYPE THERMOSTATS TO BE REPLACED. NEW THERMOSTATS TO B£ REQUIREMENT TO PROVIDE THE SPECIFIED ITEMS UNLESS SPECIFICALLY NOTED ASA SUBSTITUTION BY THE a, EXISTING GYP BOARD/PLASTER-SAND,SPACKLE ALL IMPERFECTIONS,SPOT PRIME AND FINISH TO CONTRACTOR AND SPECIFICALLY APPROVED BY THE ARCHITECT AS SUCH.REPLACE SUCH PRODUCTS AS HONEYWELL COMMERCIAL GRADE WSIONPRO 8000 TOUCH SCREEN MODEL T8822OU1003 WHERE POSSIBLE DIRECTED AT CONTRACTOR'S COST. ACHIEVE UNIFORM COVERAGE WITH MILLER'S 620008 4480. APPROVED SUBSTITUTE: TOTAL-LINE SIGNATURE COMMERCIAL THERMOSTAT MODEL NO P374.2800 -7 DAY B 23,000 SF BASE AREA .^. T 24.SUBMIT COMPLETE SHOP DRAWINGS FOR MILLWORK,SPECIAL SYSTEMS,MECHANICAL,ELECTRICAL AND b. NEW GYP BOARD/PLASTER -PRiME WITH SUPER SEAL AND FINISH TO ACHIEVE UNIFORM COVERAGE PROGRAMMABLE WITH LOCKOUT FUNCTION-AUTO CHANGEOVER ONLY. MOUNT DAHEIGHT(MAY 69,000 SF 300%INCREASE FOR MULTI STORY WITH MILLER'S 6200 OR 4480. REQUIRE CHANGING HEIGHT AT"REPLACEMENT"LOCATIONS). CONTRACTOR SHALL PROGRAM 46,000 SF 200%INCREASE FOR SPRINKLERS T V O PLUMBING SYSTEMS(INCLUDING FIRE PROTECTION SYSTEMS). SUBMIT A MINIMUM OF TWO COPIES OF ALL THERMOSTATS AND BALANCE SYSTEM. SHOP DRAWINGS FOR REVIEW AND APPROVAL TO THE ARCHITECT OF RECORD.ARCHITECT WILL RETAIN ONE 4. GENERAL NOTES: 17,250 SF 75%INCREASE FOR FRONTAGE COPY AND ONE COPY WILL BE RETURNED TO THE CONTRACTOR. 21.THERMOSTAT LOCATIONS TO BE REVIEWED BY ARCHITECT PRiOR TO INSTALLATION. a. KEEP ALL HARDWARE,HINGES,AND DOOR KNOBS CLEAN OF ALL PAINT SPLATTERS,DRIPS,OR ROLLER 155,250 SF TOTAL ALLOWABLE AREA 4t 25.THE DESIGN OF FIRE PROTECTION SYSTEMS IS THE RESPONSIBILITY OFTHE FIRE PROTECTION SYSTEMS SPRAY. 22.EXHAUST FANS: CONTRACTOR.ALL FiRE PROTECTION SYSTEMS SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER b. ALL SURFACES TO BE SANDED BETWEEN COATS,PRIOR TO INSTALLATION OF NEXT COAT. a. CEILING MOUNTED EXHAUST FANS SHALL HAVE A MINIMUM PERFORMANCE TO MEET THE CURRENT EL LICENSED BY THE APPROPRIATE JURISDICTION FOR THE DESIGN OF THIS TYPE OF SYSTEM. COORDINATE CODE REQUIREMENTS INCLUDING INTEGRAL BACKDRAFT DAMPER AND VENTING TO THE EXTERIOR. INTERFACE WITH EXISTING BUILDING SYSTEMS AND WITH ARCHITECT. ALL SPRINKLER HEADS SHALL BE c. DURING PROGRESS OF WORK,KEEP JOB SITE CLEAN OFALL PAINT MATERIALS,RUBBISH,CANS,AND COOK GEMINI SERIES 100 OR EQUAL;80 CFM WITH A SONE RATING OF 1.6 OR LESS,100 CFM WITH A BUILDING LOCATION CENTERED IN CEILING TILE(OR 2 x 2 MODULE OF A SECOND LOOK 11 TYPE OF CEILING TILE WHERE RAGS AT THE END OF EACH DAY. SONE RATING OF.9 OR LESS,200 CFM WITH A SONE RATING OF 1.6 OR LESS. I, (F APPLICABLE). LOCATION OF THOSE IN GYPSUM BOARD CEILINGS SHALL BE PRE-APPROVED IN WRITING BY d. UPON COMPLETION OF WORK,CLEAN ANY PAINT SPLATTER BY USING PROPER METHODS OF WASHING b. SINGLE FIXTURE RESTROOMS,JANITOR'S CLOSETS OR SINGLE SHOWER ROOMS TO HAVE CEILING YI THE ARCHITECT PRIOR TO INSTALLATION. AND SCRAPING,USING CARE NOT TO SCRATCH OR DAMAGE FINISHED SURFACES. MOUNTED EXHAUST FANS,WIRED PER DIVISION 16 AND SWITCHED WITH THE LIGHTS. 26.COORDINATE ALL CONSTRUCTION SEQUENCING WiTH PACTRUST AND SCHEDULE ALL SERVICE . c. MULTIPLE FIXTURE RESTROOMS, e. PROTECT WORK OF OTHER TRADESOMS,COMBINATION RESTROOM&SHOWER,AND LOCKER ROOMS TO HAVE ��✓ INTERRUPTIONS OUTSIDE NORMAL BUSINESS HOURS TO MINIMIZE INCONVENIENCE TO CURRENT TENANTS, TOPORT6AM C ROOFTOP MOUNTED EXHAUST FAN FACTORY CURB AND BACKDRAFT DAMPER,WIRED PER DIVISION 16, ARMAN1i°' f. PROVIDE"WET PA1NT SIGNS AS REQUIRED TO PROTECT NEWLY PAINTED FINISHES. GENERAL CONTROLS AS REQUIRED BY DESIGN.COOKACE-D SERIES OR EQUAL. 1. REMOVE ALL EXISTING VCT,SHEET VINYL,ETC.IN AREAS WHERE NEW FLOOR COVERING IS SPECIFIED PRIOR 10 00 00 SPECIALTIES d. SPECIALTY ROOMS REQUIRING EXHAUST SHALL MEET THE ABOVE MINIMUM REQUIREMENTS- 12 13 15 Fes" TO INSTALLATION OF NEW FLOORING. 10 28 13 BREAK COUNTER INDIVIDUAL ROOMS WITH AN EXHAUST REQUIREMENT GREATER THAN 250 CFM,WILL REQUIRE THE USE 08 10 00 DOORS AND WINDOWS 1. PAPER TOWEL DISPENSERS,SURFACE MOUNTED(KITCHEN/BREAK ROOM)BOBRICK B-262 OF A ROOFTOP MOUNTED FAN. 1�1--+� o■ N O N 76 1. RE-USE EXISTING DOORS AND FRAMES WHERE POSSIBLE 12 00 00 FURNISHINGS 24.HVAC TESTING. t--1-�� 14 , +� 2. APPROVED DOOR,FRAME,AND HARDWARE SUPPLIERS INCLUDE: 1. CLEAN/REFURBISH EXISTING BUILDING STANDARD BUa. CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES,COMPONENTS NDS AT EXTERIOR GLASS. 11 EQUIPMENT AND SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH a. BAXTER AND FLAMING. (503)225-0486 2. INSTALL BUILDING STANDARD ADDRESS AND/OR SUITE NUMBER LABELS TO ALL EXTERIOR DOORS. APPROVED PLANS AND SPECIFICATIONS. b. D&D DOOR (503)205 5533 12 23 16 CABINET SPECIFICATIONS b. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTEaTO ENSURE THEY OPERATE IN ( ) 1. ALL CABINETRY TO BE INSTALLED OVER FINISH FLOOR ATALL RESILIENT FLOORING LOCATIONS. ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. - e t c. BENSON INDUSTRIES 503 907-2200 3 e � d. GRANT SUPPLY (360)887-0647 2. AWI CUSTOM GRADE STANDARDS FOR CASEWORK AND COUNTER TOPS U.N.O c. A COMPLETE COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND 4 3 /rte FILED WITH PACTRUST. 3. DOOR AND RELITE FRAMES SHALL BE WESTERN INTEGRATED MATERIALS(WIM). SUBMITTAL REQUIRED PRIOR TO ORDERING MATERIAL.NEW FRAMES TO BE FACTORY FINISH CUSTOM COLOR. ). .HIGH PRESSURE LAMINATE(P-LAM HPL)ALL EXTERIOR SURFACES,INCLUDING 4"TOE KICK EDGE BANDING 25.PROJECT CLOSE OUT DOCUMENTS REQUIRED: 10 (MATCHING PVC ACCEPTABLE),FIN ENDS,DOORS,AND LIGHT VALENCE ETC. UPPER CABINET BOTTOMS 4. FIELD VERIFY EXISTING DOOR,FRAME AND HARDWARE FINISH PRIOR TO ORDERING. ALL NEW DOORS, OPTIONAL HPL FINISH,STANDARD MELAMINE FINISH. OPEN CABINETS OPTIONAL HPL FINISH,STANDARD a. AutoCAD FILE SHOWING AS-BUILT INFORMATION. FRAMES AND HARDWARE TO MATCH EXISTING BUILDING STANDARDS. MELAMINE FINISH. b. ELECTRONIC PDF FILE OF THE AutoCAD FILE ABOVE, 5. ALL INTERIOR DOORS SHALL BE SOLID CORE WOOD UNLESS NOTED OTHERWISE. 4. TOE KICK PLYWOOD 4"H WiTH P-LAM COVER c. HARD COPY OF AutoCAD FILE ABOVE. 6. DOOR HARDWARE SHALL BE SCHLAGE AL SATURN OR D RHODES SERIES U.N.O. 5. DOORS AND DRAWER FRONTS PLASTIC LAMINATE OVER 11/16"PARTICLE BOARD WITH MATCHING P-LAM OR d. OPERATIONS MANUALS FOR ALL EQUIPMENT,INCLUDING T-STATS. 7. ALL DOOR HARDWARE SHALL BE INSTALLED WiTH A 5'BACKSET, PVC EDGES. e. COLORED ZONE MAP WITH THERMOSTAT LOCATIONS INDICATED. I LOCATION MAP z 8. DOOR FINISH SUBMITTAL:CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR DOOR FRAMES DOOR 6. MELAMINE(LOW PRESSURE LAMINATE!LPL)ALL INTERIOR AREAS,DRAWER PARTS,SHELVING ETC. A-L SCALE 1"=600' 7. FLUSH OVERLAY/FRAMELESS STYLE CONSTRUCTION. 26 00 00 ELECTRICAL :DESIGN/BUILD HARDWARE AND DOORS AS WELL AS A CONTROL SAMPLE OFTHE FINISHED DOOR SKIN WlSTAIN AND FINISH GENERAL APPLIED(IF NEW DOORS ARE BEING PROVIDED). BEFORE FINISHING OF DOORS IS COMMENCED ARCHITECT 8. HINGES-BLUM#75M3580,110 DEG.SELF CLOSING CLIP ON(OR EQUAL). SHALL APPROVE CONTROL SAMPLE. FINISHED PRODUCT IS SUBJECT TO REJECTION BY ARCHITECT IF THIS 1. ALL ELECTRICAL FEEDS TO OUTLET,SWITCHES,ETC.MUST BE VERTICAL DROPS FROM CEILINGS U.N.O. PROCESS IS NOT FULLY ADHERED TO AND FIELD PRODUCT DOES NOT MATCH THE APPROVED CONTROL 9. DRAWER SLIDES-BLUM #230M SERIES EXTENSION(OR EQUAL)75 LBS.MIN.FOR STANDARD DRAWERS. EXCEPT FOR HORIZONTAL RUNS UNDER WINDOWS AND FIXTURES ON THE SAME STUD. + z a s s s s p + SAMPLE. ACCURIDE#4032(OR EQUAL)HD/FULL EXT 150 LBS.MIN.FOR HD AND FILE DRAWERS. 9. ALL INTERIOR GLAZING SHALL BE TEMPERED. 10.PULLS-96 MM C-TO-C WIRE PULLS. FINISH TO MATCH DOOR HARDWARE. 2. ALL ELECTRICAL FEEDS TO OUTLETS AND DATA BELOW WINDOWSILLS TO BE ROUTED THROUGH BUILDING ,Qa sd aaa +sa aa+r ma aaa �y/ SHELL WALLS. DO NOT FEED FROM PERPENDICULAR INTERIOR PARTITIONS. 10.DEAD BOLT LOCKS AT NEW EXTERIOR DOORS TO BE INSTALLED WITH A SCHLAGE MORTISE DOUBLE 11.GENERAL CONTRACTOR TO PROVIDE CABINET MAKER WITH SINKTEMPLATE(SPEC SHEETS)FOR EACH SINK 3. PROVIDE LABELS AT EACH ELECTRICAL RECEPTACLE IDENTIFYING CORRESPONDING PANEL AND BREAKER. , CYLINDER 20-013C "C'KEYWAY;SOLID BRASS;WITH ADAMS-RITE CAM AND COMPRESSION RING 1 1/8"LENGTH SiNK CUTOUT SHALL BE DONE IN SHOP WHEN FEASIBLE AND BEFORE BACK SPLASH IS INSTALLED IN ALL WITH HARDENED CYLINDER GUARD RING KEEDEX K-24. FINISH TO MATCH BUILDING STANDARD. CASES TO ALLOW CUTOUT TO BE POSITIONED PROPERLY. ALL RAW EDGES OF CUTOUT AND BACK SPLASH 3. PROVIDE UPDATED SCHEDULE AT PANEL TO IDENTIFY CIRCUIT BREAKERS. TO BE SEALED. MINIMIZE COUNTERTOP BUILDUPS AT FRONT AND BACK OF SINK CUTOUT TO o 11.PATCH AND REPAIR ALL HOLES OR DAMAGE TO EXISTING STOREFRONT WINDOWS AND DOORS.TOUCH UP 4. VERIFY ELECTRICAL METER AND TAG METER WITH THE TENANT'S ADDRESS OR SUiTE NUMBER. METER FINISH FOR AS NEW LOOK ACCOMMODATE PLUMBERS SINK CLAMPS CLEARANCE. o $ I I I C4 IDENTIFICATION NUMBER AND TENANT ADDRESS INFORMATION SHALL BE GIVEN TO PACTRUST PRIOR TO 12.KITCHEN/BREAK ROOM CABINETS-BASE CABINET WiTH P-LAM TOP ON PLYWOOD DECKING AND 4"BACK TENANTS MOVE-IN. EA 12.TOUCH UP ALL EXISTING INTERIOR DOORS AND FRAMES FOR AS NEW LOOK $ ' SPLASH. ALL CABINETS TO HAVE DOORS AND DRAWERS,U.N.O. UPPERS 12 D X 36"H-ATTACH TO WALL __ __ _ _ con "/""'� t 5. ELECTRICAL CONTRACTOR TO PROVIDE EMERGENCY LIGHTING IN PATH SHOWN ON PLAN EQUALTO 1-FOOT e - __ ___ _ ___- _ -_ - �✓..i U 09 00 00 FINISHES WITH FRENCH CLEAT,COUNTER AND COUNTERTOPS 26'D. MICROWAVE SHELF 18"D WITH 3"RADIUS OUTSIDE CANDLE. � _ CORNERS. P-LAM AT TOEIBASE. ALL SHELVES ADJ.HOLES AND POSTS(1 AT BASE,2 AT UPPERS). $ GENERAL 6. EXIT LIGHTS:RUUD LIGHTING"PLASTIC LED EXIT SIGN"MODEL EXPBURWH RED LETTERS,WHITE HOUSING, F - -� - - --- - - '"/`� C4 1. CLEAN,SEAL AND WAX ALL RESILIENT FLOORS PER MANUFACTURERS SPECIFICATIONS. 2100 Oq FIRE SUPPRESSION :DESIGN/BUILD WITH BATTERY BACKUP. o 1. ADJUST EXISTING SPRINKLERS BELOW SUSPENDED CEILING PER CODE. SPRINKLER HEADS SHALL BE 7. WHERE NEEDED,CONTRACTOR TO FURNISH AND INSTALL NEW DRY TYPE TRANSFORMERS TO PROVIDE I I I ' It- 2. SUBMIT SAMPLES OR DRAW DOWNS FOR THE FOLLOWING: CENTERED IN 2 X 2 CEILING TILE.LAYOUT OF SPRINKLERS BY CONTRACTOR. SPRINKLER LAYOUT IN ALL HARD 208V/120V POWER FROM THE 480V277V SYSTEM. SIZE TO BE BIDDER DESIGN. a. FLOOR COVERINGS AND BASE CEILING AREAS(GYPSUM BOARD/PLASTER)TO BE REVIEWED AND APPROVED BY ARCHITECT PRIOR TO a ----I----- --- - -- - - ---- '----- O ►a �� INSTALLATION. a. TRANSFORMERS TO BE ENERGY STAR LABELED. ` 0 b. PLASTIC LAMINATES 2. iN NEW CEILING GRID SYSTEMS OVER 144 SF PROVIDE FLEXIBLE HEADS FOR MINIMUM SEISMIC MOVEMENT. b. CASE TO BE TOTALLY ENCLOSED WITH LOUVERS TO PREVENT FOREIGN OBJECTS INTO THE INTERIOR. ' c. ALL NATURAL WOOD(INCLUDING DOORS AND CASEWORK) NO`OOPS RINGS ALLOWED'. H ff c. ENCLOSED AND VENTILATED,AIR COOLED TYPE,CLASS H INSULATION,DESIGNED FOR 115 DEGREES C d. PAINT 22 00 00 PLUMBING TEMPERATURE RISEABOVE 40 DEGREES C AMBIENT TEMPERATURE AT FULL LOAD CONTINUOUS e. TiLE,MARBLE,GRANITE,STONE,AND GROUT OPERATION. EQUIP WITH 2-12 PERCENT ANFC TAPS AND FOUR 2-12 PERCENT BNFC TAPS. MAXIMUM 9 GENERAL REQUIREMENTS SOUND LEVEL SHALL BE NEMA STANDARD WITH ISOLATION DAMPERS BETWEEN THE CORE AND COIL--- - f. TOILET PARTITIONS ASSEMBLY AND CASE. _ _ O 1. CONTRACTOR TO SUBMIT LAYOUT ON ELEVATIONS AND PLANS PROVIDED FOR ALL SHUT OFF VALVES,CLEAN K - V M g. HARDWARE OUTS,ACCESS DOORS,AND FLOOR DRAINS TO THE ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION. 9. FOR FLOOR POWER AND DATA ACCESS iN BUILDINGS WITH ACCESS BELOW FLOOR,USE WIREMOLD RC7 3. EXTEND FINISH FLOORING UNDER ALL NEW CASEWORK 2. PLUMBING CONTRACTOR TO PROVIDE AND INSTALL(1)MASTER SHUT OFF VALVE FOR EACH SET OF FLUSH POKE THRU SERIES OR EQUAL. FOR SLAB ON GRADE INSTALLATIONS USE RACO#5511,2 AT EACH AREA OF WORK =JZ p t � a RESTROOMS. LOCATE VALVE BEHIND HANDICAP TOILET IN MEN'S RESTROOM. LOCATION TO SEPARATE POWER AND DATA WITH 1'CONDUIT FOR POWER AND r CONDUIT FOR DATA. � BUILDING PLAN rT �T 09 21 04 GYPSUM BOARD 3. ALL DOMESTIC WATER PIPING TO BE TYPE L COPPER-NO EXCEPTIONS. ALL EXPOSED PIPING TO BE 10.TELECOMMUNICATION SYSTEM BY FUTURE TENANT. Ze REVISION GENERAL INSULATED. 11.LiGHTiNG ENERGY MANAGEMENT IS REQUIRED IN ALL BUILDINGS. SCALE 1"=40' 1. ALL GYPSUM BOARD TO BEA MiNIMUM OF SW THICK VERTICALLY ATTACHED TO METAL STUDS 24 O.C.WITH 4. WATER HEATER(ELECTRIC)30 GAL AND LARGER 277V LESS THAN 30 GAL 12OV. PROVIDE HUB DRAIN AT 12.OCCUPANCY CONTROL DEVICES SHALL BE LEVITON OR WATT STOP. 1'TYPE S-12 SCREWS 12"O.C.UNLESS OTHERWISE NOTED. LOCATION. 2. ALL OFFICE GYPSUM BOARD TO RECEIVE ONE TAPE COAT AND TWO FiNISH COATS WiTH SANDING BETWEEN 5. POINT OF DEMAND WATER HEATER-BOSCH POWER STREAM PRO-MODEL RP2P 277Vf30A. ADJUST WATER 13.TEST ALL LIGHTING CONTROL SYSTEMS TO ENSURE THAT CONTROL DCOMPONENTS,EQUIPMENT Z. FINISH COATS. APPLY USG SHEETROCK BRAND FIRST COAT. PAiNT AS INDICATED. FLOW SETTING TO PROVIDE A HEATING RANGE OF 105 TO 120 DEGREES. CONTACT MESHER SUPPLY FOR SPECIFICATIONS. SEQUENCES OF OPERATION SHALL BE FUN AND SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE ACCORDANCE TESTEEDDWITH APPROVED PLANS AND = . TO ENSURE TRAY OPERATE 3. ALL OTHER GYPSUM BOARD TO RECEIVE ONE TAPE COAT AND ONE FINISH COAT WITH SANDING AFTER FINISH AVAILABILITY,(503)236.4148. IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. 2' COAT. PAINT AS INDICATED. 6. FLOOR DRAINS SHALL BE INSTALLED iN TOILET ROOMS CONTAINING TWO(2)OR MORE WATER CLOSETS OR 2 14.REQUIRED IN DIVISION 15,PROVIDE MONITORING OF HVAC EQUIPMENT PER CODE. 13. 4. ALL ONE HOUR RATED WALLS(WHERE APPLICABLE): ONE LAYER 5T TYPE X GYPSUM WALLBOARD,EITHER EXCEPTION-UNUSED DATA EXC OR MORE WATER CLOSETS AND URINALS IN COMBINATION.THE FLOOR SHALL SLOPE TOWARD THE FLOOR . AT RIGHT ANGLES OR PARALLEL TO FRAMING ON EACH SIDE OF METAL STUDS SPACED AT 24 O.C. FASTEN 15 BOXES UNDER WINDOW SILLS TO REMAIN. ALL BLANK COVER PLATES TO BE REMOVE ALL UNUSED DATA AND POWER BOXES AND INFILL WiTH GYP BOARDEXCBUILDNG STANDARD FINISH. Q. WITH 1"TYPE S DRYWALL SCREWS 8"O.C.TO VERTICAL EDGES AND IT O.C.TO TOP AND BOTTOM RUNNERS 7. FLOOR DRAINS TO BE INSTALLED WITH PRIMER VALVE WITH ISOLATION VALVE. NO ATMOSPHERIC PRIMERS. _ AND INTERMEDIATE STUDS. STAGGER ALL VERTICAL AND HORIZONTAL JOINTS 24"O.C.(OR ONE STUD DRAINS TO BE PRIMED FROM TOILET FIXTURES UNLESS APPROVED BY OWNER. PROVIDE A MIN.OF 12" 16 REMOVE ALL UNUSED BOARD.LOW VOLTAGE WIRING FROM T E BOXTOTHE)FROM THE PACE ABOVE THE TA CEILING.TO SECTION CITY OF 7TGARD �• SPACING),EACH SIDE AND OPPOSITE SIDES. ACCESS DOOR. - 5. IN FINISHED SPACES FURR-OUT BUILDING COLUMNS AND EXTERIOR WALLS WiTH 5/8"GYPSUM BOARD OVER PLUMBING-BREAK ROOM FIXTURES OF THE EXISITNG LOW VOLTAGE WIRE MAY BE LEFT IN LIEU OF A PULL STRING REVIEWED FOR CODE CONLPLIANCS 6, 2. KITCHEN FAUCET DELTA 100-DST METALSTUDS. 1. BREAK ROOM SINK ELKAYGECR2521 OFFICE LIGHTING i 6. PROVIDE ACOUSTIC GASKETS WHERE WALL INTERSECTS MULLIONS OR GLAZING. 1. GROUP RE-LAMP EXISTING FLUORESCENT LIGHTS THROUGHOUTAS NEEDED. APPd' ''7 7" f 7. AT ALL EXISTING WALLS,REMOVE ALL NAILS,SCREWS,FASTENERS,ETC.LEFT BY PREVIOUS TENANT AND 2. OFFICE LIGHT FIXTURES- LITHONIA 2PM3N G B 3 3218LD MVOLT ADVANCE OR EQUAL(NO SYLVANIA OTC: PATCH HOLES READY FOR PAINT. 3 REQUIRED. WATER LINE W/SHUT OFF VALVE FOR COFFEE MAKER AND REFRIGERATOR,SEPARATE LINES iF BALLASTS) s i 8. 8. UPON REMOVAL OF WALL BASE,REMOVE RESIDUAL ADHESIVE AND PREP WALLTO PAINT READY CONDITION. 28 30 00 ELECTRONIC DETECTION AND ALARM Pcffrift#. LL P'96 I 1, WALL CONSTRUCTION MATERIALS 23 00 00 HVAC :DESIGN I BUILD GENERAL Address; HVAC-BID PROCEDURE DRAWN BY: t. PROVIDE STUDS,TRACKS,BRACING,FASTENING AND OTHER ACCESSORIES NECESSARY FOR COMPLETE FOR HORN/STROBE DEVISES USE'SYSTEM SENSOR"SPECTRALERT ADVANCE DEVISES,OR APPROVED EQUAL Suite#; Z '� INSTALLATION. 1. FOR BiDDING PURPOSES,THE HVAC CONTRACTOR WILL ASSUME THAT EXISTING HVAC EQUIPMENT 6S IN Br- PROPERTIES � t R.M.T. 2. FRAMING MEMBERS SHALL HAVE THE STRUCTURAL.PROPERTIES INDICATED WHERE PHYSICAL STRUCTURAL PROPER WORKING ORDER. D1te; t DATE: DESIGN FRAMING N ACCORDANCE THEY SHISI ALL BEA NECESSARY TO WITHSTAND ALL IMPOSED LIVE LOADS. 2. INVENTORY RNTORY EXISTING H.VA.C.ROOFTOP UNITS AND SUBMITTOARCHITECTA CONDITIONS REPORT OF EACH DATE: 31��4jj115 �r 3. LIST TONNAGE OF EACH UNIT. ` PERNUT/ BID SET 3. COLD-FORMED FRAMING SHAH BE GALVANIZED METAL CONFORMING TO ASTM A4461A 446 M GRADE A(33000 ������ ���� PSI)G60. HVAC-DESIGN PROCEDURE 4. PROVIDE THE LISTED GYPSUM BOARD PRODUCTS BY U.S.GYPSUM,GEORGIA PACIFIC,NATIONAL GYPSUM OR USE EXISTING AND/QR NEW EQUIPMENT TO DESIGN MECHANICAL H.V.A.C.SYSTEM PER DESIGN STANDARDS AN APPROVED EQUAL LISTED BELOW. 5. STANDARD GYPSUM BOARD SHALL BE TYPE W,5/8"THICK WITH TAPERED EDGES CONFORMING TO ASTM PRIOR TO AWARD OF CONSTRUCTION CONTRACT,H.V.A.C.CONTRACTOR SHALL SUBMIT TO ARCHITECT FOR Com- REVIEW AND APPROVAL A FULL DESIGN SCHEMATIC FOR THE TENANT SPACE INCLUDING BOTH 6. WATER RESISTANT GYPSUM BOARD SHALL BE 5!8"THiCK WiTH TAPERED EDGES. CONFORMINGTOAST•M NEW/RENOVATED WORK AND SYSTEMS UNTOUCHED BY THE TENANT IMPROVEMENT AS APPLICABLE. Com. INCLUDE THE FOLLOWING: 7. AT TOILET ROOMS USE 51W USG FIBERROCK BRAND AQUATOUGH INTERIOR PANEL FROM FLOOR TO 48"A.F.F. a. DUCTING AND SiZES ON WALLS BEHIND OR ADJACENT TO PLUMBING FIXTURES. NO SUBSTITUTES.(EXCEPTION:EXCEPTION AT b. SUPPLY AND RETURN LOCATIONS AND CFM LOCATIONS TO RECIEVE PLASTIC LAMINATE OR TILE WAINSCOT.) 8. AT TILE WAINSCOT LOCATIONS INSTALL CEMENT BACKER BOARD W THICK WiTH SQUARE,REINFORCED, c. ROOF EQUIPMENT,SIZES AND LOCATIONS SMOOTH EDGES. PROVIDE DUROCK BRAND CEMENT BOARD OR APPROVED EQUAL d. UNITS REQUIRING DUCTED SMOKE DETECTION BUILDING DEPARTMENT USE FINISH MATERIALS (FOR BUDGET ONLY)R B ET N ABBREVIATIONS #3082 1 ALL FINISHES MUST BE SUBMITTED TO PACTRUST PRIOR TO INSTALLATION. BRK BRICK PAVERS MARTIN W. HANSON ` � � � � � CPQ CUT PILE CARPET (� CARPET LOOP PILE: CR CHAIR RAIL CLA KAM S, OREGON LP PATCRAFT COLOR CHOICE-00557 DOLPHIN, (COLOR T.B.D.), DIRECT GLUE E EXISTING 'A ETR EXTEND TO ROOF BASE FWC FABRIC WALL COVERING ZRF JOHNSONITE 4"FLAT RUBBER BASE,63 BURNT UMBER AT ALL CARPET AREAS. GT GROUT OF U o Z�rRC JOHNSONITE 4"COVE RUBBER BASE,63 BURNT UMBER AT ALL HARD SURFACES. HM HOLLOW METAL - PGWB PAINTED GYPSUM WALL BOARD c PAINT: PL-# PLASTIC LAMINATE PROJECT #15160 PT-1 MILLER 4480 PREMIUM SATIN 0539 PLACE OF DUST,SATIN LATEX. PLW PLASTIC LAMINATE WAINSCOT PT-2 MILLER- 4480 PREMIUM SATIN 0542 CAPTAIN NEMO,SATIN LATEX (ACCENT COLOR) POT PORCELAIN TILE CONTACT FOR PACTRUST PRICING,&ORDERING INFO:AMY TACKE 503-348.3307 POTW PORCELAIN TILE WAINSCOT [�I PT-# PAINT LAMINATE: RC RUBBER BASE COVED W RF RUBBER BASE FLAT PLA WILSONART 7949K-18 ASIAN NIGHT,AT ALL FACES SAT SUSPENDED ACOUSTICAL TILE H I CONTACT TECH SERVICES: $00-433-3222 PNoraE PL-2 NEVEMAR S6029T GUNMETAL,COUNTER,B.S.AND SELF-EDGE.A� SC SV SHEETVINYL RETE CAB PULLS 613 OIL RUBBED BRONZE STOR l BREAK VCT VINYL COMPOSITION TILE A2 201RECE DOORS, HARDWARE AND FRAMES WBC WALL BOARD CEILING 66'MIG SHREDDER ® I HARDWARE 613 OIL RUBBED BRONZE WCG WALL CORNER GUARD WD WOOD HT TBD. FRAMES MATCH EXISTING WOC WALK OFF CARPET • A 8'�: I �> �� �> CONTRACTOR TO PROVIDE BUILDING STANDARD BLINDS AT ALL EXTERIOR GLASS. WW WINDOW WALT Z o - :< I 1 a _ CONFERENCE e -- r F2031 DOOR SCHEDULE - o II OPEN OFFICE � �- OPEN OFFICE -- I DOOR DATA ,, r-y • FRAME DATA HARDWARE n 4 ® � 202 N \i��� �,, Fire Rat Remarks Mark W �'.d' A_z ,_U Mark Door Size Thk Core Veneer Finish Nand __ Type Frame Depth Hardware Manufacturer Finish Function to ty eq _8. � - 2@1 3'-@' x 9'-0' 1 3/4' SC BIRCH BJ DOOR FINISH 1@@1@2 i ht • WIM 4 1/8' L OCK SCH AG 6113 OI BED ONE A I@S -- 2@1 3'-�' ' R LEVER/LOCK L E L RC1 B BR Z L ,� r,,M ------ __ , 203A 3'-0' x 9'-@' 13/4' SC BIRCH BJ DOOR FINISH 100102 Left • WIM 4 U8' LEVER LATCH SCPLAGE 613 OIL RUBBED BRONZE AL105 18' SIDELITE 203A o a eG „ 2035 2 -6 x 9-@ 13/4' 5C 81RC4 BJ DOOR FIN15P 100102 Right • WIM 141/8' LEVER LATCH 5CNLAG�E 613 OIL RUBBED BRONZE AL105 -- 2038 0 x�+ b x b 6 x 6 -� 2@6 3'-@' x 9'-0' 13/4' SC BIRCH BJ DOOR FINISH 100102 FZ ht • WIM 41/8' LEVER LATCH SCNLAGE 613 OIL RUBBED BRONZE AL105 -- 2@6 ^'a+ �+Pk ' RECITE zmb 209 RELITE iC' 2@1 3'-@' x 9'-0' 13/4' SC BIRCH BJ DOOR FINISH 100102 Left • WIM 4 1/8' LEVER LATCH SCHLAGE 613 OIL RUBBED BRONZE AL105 RELOCATED DOOR AND FRAME 201 F@=3 x 9'-0, 1 3/4' 1 SC BIRCH BJ DOOR FINISH 100102 Right • WIM 41/8' 1 LEVER LATCH 5CHLAGE 613 OIL RUBBED BRONZE AL105 -- 2@8 OFFICE OFFICE 1209 3'-0' x 9'-@' 13/4' SC I BIRCH BJ DOOR FINISH 10Nl@2 Left 1 • 1WIM 4 1/8' LEVER LATGN SGNLAGE 613 OIL RUBBED BRONZE ALl@S RELOCATED DOOR ANp FRAME 2@9 ® CIRC. ® , 5 FINISH SCHEDULE 6x6 6X6 ,� --,, WALLS W �I''E I RMO NAME FLOOR BASE CEILING CLC. REMARKS i� o �� NORTH EAST 5OUTH WEST HT. N Q PA 200 RECEPTION LP 4' RF PGWB E-PGWB E-PGWB PGWB E-5AT 9'-@' -- 200 a 13 zoT Zoe 201 5TOR /BREAK LP 4' RF E-PGxWB E-PGxWB PGWB PGWB E-5AT 9'-@' -- 201 CE OFFICE OFFICE __ ( • 2@2 OPEN OFFICE LP 4' RF PGWB PGWB E-PGWB PGsWB E-5AT 9'-@' 2@2 F Q 20� 2°$ 203 CONFERENCE LP 4' RF PGWB E-PGWB FGWB PGWB E-SAT 9'-0' -- 203 LL 204 OPEN OFFICE LP 4' RF E-PGWB PGWB PGWB PGWB E-5AT 9'-0' - 204 -`` -figK 205 CIRC. LP 4' RF PGWB PGWB PGsWB PGWB E-SAT 9'-@' -- 1@5 1 4k I I I - LA J=jL- 2@6 OFFICE LP 4' RF E-PGWB PGWB PGWB PGWB E-SAT 9'-@' -- 206 03 201 OFFICE LP 4' RF E-WW-PGxWB PGWB PGWB E-WW-PGW_B E-SAT 9'-0' -- 201 p 208 OFFICE LP 4' RF PGWB PGWB E-PGWB E-WW-PGWB E-5AT 9'-0' -- 208 r 209 OFFICE LP 4' RF PGWB PGWB E-PGWB PGWB JE-SAT 9'-@' -- 1@9 9 Q PARTITION AND POWER PLAN Z 2 REFLECTED CEILING PLAN Q A-2 SCALE 1/8"= 1'-0" A-2 SCALE 118"= 1'-0" Z� 13 (3 184' 183' 28�' IADJ. HELI' c4 — _ � ADJ. PELF MICRO SHELF AT IB'DEEP WITH 2' �+ RADIOUS CORNERS ® �' W t OPEN 6ACK 12 � U � 134 ' PROVIDE PAPER L GROMMETS IN COUNTER N CN`• ~ TOWEL DISPENSER Q n Ft-2 TOP FOR POWER AND 33, 33' 20' DATA ACCESS 1' 1 # 30' 21' 30' 11' 30' O BACK SPLASH CONSTRUCTION LEGEND a © W " �� - - - - - - ;414 ADA SINK r ®Fil \ ® — ® — ® EXISTING TO REMAIN V O I . ~ rn 0 ADJ.SHE LF ® — — — - -- — EXISTING TO BE REMOVED '4", U IY+ `� r = `� ADJ.SH LF ADJ.SH LF p ef,' TEN REF. C CANN&/ _ �i V1 W •-+ p.� I ® s NEW STANDARD WALL I I A 3 NEW STANDARD WALL WITH INS. REVISION L'�TfCiT!f1�T 'v OPEN BASE P-LAM BASE L _ — J -v RE Y 1►,711J1�1 13 1Z 9 IPJ It 1. DUPLEX RECEPTACLE vEw ELECTRICAL PANEL 3 CABINET ELEVATION Z@ FOURPLEX RECEPTACLE O POWER J-BOX 2. A-2 SCALE 1/2"= 1'-0" a:�) 3. DEDICATED OUTLET ® FLUSH MOUNT FLOOR MONUMENTW/POWER AND DATA 4. EXISTING ELECTRiCALTOREMAIN ER FIRE EXTINGUISHER IN RECESSED CAB. FLOOR MONUMENT W/SERVICES SHOWN FEs FIRE EXTINGUISHER-SURFACE MOUNTED 5. SPECIAL OUTLET a THERMOSTAT 6. 7. TEL/DATA MUD RING WITH PULL STRING 8. CEILING LEGEND 2 X 4 FLUOR.7$3 TUBE FIXTURE ® SUPPLY DIFFUSER DRAWN BY: PARABOLIC LENS ® F.-M.T. 2 X 4 FLUOR.FIXTURE RETURN DUCT DATE:TE: 3/4/15 PARABOLIC LENSISTEADY BURN BALLIST EXHAUST FAN p 7�,� /�pp } RECESSED LED DOWN LIGHT(TYP.) 2 X SPRINKLER HEAD PER WTABID SET STANDARD SWITCH Q EXIT SIGN(LED RED) ® OCCUPANCY SWITCH HORNISTROBE FIRE ALARM(WALL MOUNT) CEILING OCCUPANCY SENSOR al HORN/STROBE FIRE ALARM(CEILING MOUNT) G SMOKE DETECTOR i - RAGO HEAD #3082 20 GA 3 5/8'METAL STUD BRACING A AIR VENT 24' 24' MARTIN W. HANSON TO ROOF STRUCTURE AT 10-0 OC -- WHERE REQUIRED 6' 1' 1• �" CLA KAM- , OREGON„, Y_0' v LITE KIT WHERE SPECIFIED TIN Ta ,!N h /P-LAM COUNTER TOP P LAM COUNTER TOP P-LAM COUNTER TOP FF-1 ..,._. 1=XISTING SUSPEt+1DED CEtL1NG u�i y ` s. ,- �i RACO SME RECESSED REVEAL HEADER CONCEPT WALLS 01-4811;Dr �, o PROJECT #15160 I MELAMINE MELAMINE q INTERIORINTERIOR i O ADDITIONAL SWITCH ADJ. —3-50M.STUDS a 24' O.C. w w GANG LOGATI r�� r � 5/8'GYP.BIRD.BOTH SIDES 9 PROVIDE ACCESS' N cv 'ry°o to co W s� CENTER LINE OF STUD av TO POWER AND PROVIDE ACCESS 6' DATA OUTLETS i TO POWER AND t M `C DATA OUTLETS r j z AIR VENT V w \ E�LIELERICAL U IOR J-BOX U' � � z 4'RUBBER EASE-TTP. `L ATTACH BOTTOM TRACK TO FLOOR WITH POWDER DRIVEN ANCHORS AT 12'O.C. UNDERCUT DOOR A ;Q ;o @ 3" P-LAM BASE 3' P-LAM BASE 13� P-LAM BASE /r O FINISH FLOOR p REQUIRED TO CLEA ao m v .0 6+ -.1 �✓ O FLOOR FINISH 4 1/8' 1 TYPICAL WALL SECTIONT AB TI 1CABINET SECTION s MOL1N INCr HEIGHTS 9 CABINET SECTION CTION 10 C INET SECTION 1 O A-3 SCALE 1" = 1'-0" A-3 SCALE 1/2" = If-off A-4 SCALE 1"=1'-0" A-4 SCALE V=1'-0" A-4 SCALE V=1'-0" a'N p� M t r 26' vNO(4 P-LAM COUNTER 26' TOP&BACK SPLASH 20 CSA 3 5/8'METAL STUD BRACING OVER PLYWOOD O • TO ROOF STRUCTURE AT 10'-0'OG -(I— I 1 WHERE REQUIRED —� �u=ISI - — cn oP-LW(� R-11 BATT INSULATION 4'CENTERED OVER WALL TOP& COUNTER — � o � � Q � TOP BACK SPLASH T � ,- - = OVER PLYWOOD EXISTING SUSPENDED CEILING O ADA SINK RACO SME RECESSED M WEAL HEADER CONCEPT WALLS 01-481RDT SOAP PAPER TOWEL SAN.NAP. PAPER TOWEL/ RECESSED 1"M' 3-W' BATT IN5UIL- DISPENSER DISPENSER D15PENSER DISPENSER/ TOWEL Sao DISPENSER MELAMINE INTERIOR 3-51$'MTL STUDS i 24'O.C. • *�dC14a 5/8'GYP.BRO.BOTH SIDESm a e CENTER LINE OF STUD c� t� 0 rim MELAMINE CISz — INTERIOR p r T 1 ow 3-1R' BATT INSUL.IN SOUND ATTENUATION WALLS 4'RUBBER BASE-TYP. n m _ -"+ � ATTACH BOTTOM TRACK TO FLOOR WITH 3 A "C POWDER DRIVEN ANCHORS AT 12'OL. SEAT COVER TOIL.PAPER/ GRAB BAR MIRROR 3- P-LAM BASE FINISH FLOOR DISPENSER SEAT COV.DISPJ a SAN.NAP. 41/8' DISPOSAL 2 WALL SECTION W/ SOUND INSUL. 6 ACC. - MOUNTING ]WEIGHTS MICABINET SECTION 13 CABINET SECTION � Q A-3 SCALE 1" = 1'-U' A-3 NOT TO SCALE A-4 SCALE 1"=1'-0" A-4 SCALE I"=1'-0" 13s' O I P-LAM DOOR FACES 138 FRENCH - P-LAM DOOR CLEAT FACES HANGER TYPICAL STUD FRENCH MELAMINE CLEAT MELAMINE INTERIOR 8o HANGER INTERIOR T _ TYPICAL TRACK ADJ. cy _ INSTALL STUDS WITH SAME DIMENSION (10' MIN.)FOR to BRIDGING ALIGNMENT - co NO K PANEL a P-LAM a T� INTERIOR V1 U POWDER DRIVEN pa N k ANCHORS AT 24' O.G. 2'RADIUS AT J N 12" + CORNERS tf (1)"10-16 SCREW = _ p0.� go PER STUD FLANGE ow tai P-LAM BOTTOM r U W U _ P-LABOTTOM r M 3 V1 V �., 0 A 3 WALL BASE DETAIL A 4 CABINET SECTION A-54 CABINET,SECTION cr en o SCALE 3 1-0 SCALE 1 - 1-0SCALE 1"=1'-0 REVISION i. 2. _ 3. _ ROOF DECK OR BEAM 5. 6. RACO STYLE RECESSED REVEAL 7. HEADER CONCEPT SUSPENDED CLG ASSEMBLY 8. WALLS fl-481RDT 45? — DRAWN BY: R.M.T. 20 GA 3 5/8' METAL STUD BRACING DATE: 3/4/15 TO ROOF STRUCTURE AT 10'-0' PERMIT/BID SET OC W/(2) *8 SHEET METAL SCREWS AT EACH END.BRACING TO BE PROVIDED WHERE DISTANCE BETWEEN PERPENDICULAR INTERSECTING WALLS OR HORIZONTAL BRACING BETWEEN WALLS EXCEEDS 12'-0' OG R - - tllllllll� 4 WALL BRACING DETAIL = A-3 SCALE 3" = 1'-0"