Report (6) Sotot`l - OO( c/ fl Garr eii System Power Requirements �a �,�E�o".Ao, SEP 15 20;4 a� "STa�ME"s S3 Addressable Control Panel by Honeywell CITY0 fk5 _ tj Protected Premises: TVF&R Station 51 eutl.® :' no late: V! 13// 2014 Address: 8935 SW Burnham Rd City: Tigard State: OR Zip: 97223 Prepared By: Scott Sullivan Advanced Alarm Systems Inc. Phone: 503-550-0999 Address: 1030 NW Corporate Drive Email: City: Troutdale State: OR Zip: 97060 Secondary Load Requirements 6.83 Amp Hours Total Secondary Load from the calculation table below. Current Draw Time (hours) I Total (AH) Secondary Standby Loadx Required Standby Time 0.225 A 24 hours 5.39 Secondary Alarm Load Required Alarm Time (hours) 3.611 A x 0.084 hours 0.30 Total Secondary Load 5.69 Derating factor x 1.20 Secondary Load Requirements 6.83 AH Battery Selection 12.00 Amp Hours Select batteries from the list • 12 AH Battery (12 volt) Battery Distribution Chart Shows amp-hour distribution of your selections. •Spare Battery Capacity Secondary Alarm Load 3% ■Secondary Standby Load Secondary Alarm Load ->: Spare Battery Capacity 43% Secondary Standby Load 54% Spare Battery Capacity 5.17 Amp Hours Secondary Standby Load 6.47 Amp Hours Secondary Alarm Load 0.36 Amp Hours aGarnentell System Current Draw FIDI s72S3 Series Addressable Control Panel h,Hon Total Standby 0.225 A Total Alarm 3.611 A Standby Current Alarm Current Device Qty Draw Standby Qty Draw Alarm 1.System Device SLP-E3 Smart Loop Panel Main Board 1 x 0.10000 0.10000 1 x 0.18000 0.18000 FLPS-7-Power Supply 1 x 0.00000 0.00000 1 x 0.00000 0.00000 SLC-PM-SLC Expander(System Sensor) 0 x 0.01400 0 x 0.01400 SLC95-PM-SLC Expander(Apollo) 0 x 0.01600 0 x 0.01600 3.S3 Optional Modules DACT-E3-Digital Communicator - 1 x 0.01800 1 x 0.01800 0.01800 LCD-7100/RAN-7100-Remote Serial Annunicator 1 x 0.12000 0.12000 1 x 0.23000 0.23000 4.Smoke Detectors/Modules Addressable Smoke/Heat ASD-PL2F/ATD-RL2F 10 x 0.00030 0.00300 0 x 0.00650 Addressable Input Module AMM-2F/AMM4-F 2 x 0.00038 0.00075 0 x 0.00060 Addressable Output Module AOM-2RF 0 x 0.00030 0 x 0.00030 Addressable Signal Module AOM-2SF 0 x 0.00030 0 x 0.00030 Addressable Pull Station MS-7AF 3 x 0.00030 0.00090 0 x 0.00100 5.Notification Appliances NAC 1 1 x 0.00000 0.00000 1 x 0.84500 0.84500 NAC 2 1 x 0.00000 0.00000 1 x 1.39800 1.39800 I NAC 3 1 x 0.00000 0.00000 1 x 0.94000 0.94000 0 x 0.00000 0 x 0.00000 Total Standby 0.225 A Total Alarm 3.611 A Load: Load: C.).N SYSTEM ,... SENSOR' advanced Ideas. 'w'iri ec jtc Job Name: TVF&R FIRE STATION Si Prepared By: Scott Sullivan 8935 SW BURNHAM RD. Advanced Alarm Systems Inc. 1030 NW Corporate Drive TIGARD , OR 97223 Troutdale, 97060 503-290-4091 Circuit Information Panel Name: FACP (2) amp circuit Circuit Name: NAC CKT 1 Class B @ 14 AWG Starting Voltage: Starting Voltage = 20.4 DC 24 - volt Supply Type and Model Candela Current Tone and Volume Dist from last Dist from 14 device(ft) source(ft) Horn/Strobe 15 0.066 Temporal, Low 15 15 20.319 P2W Strobe 15 0.066 15 30 20.245 SW Strobe 15 0.066 25 55 20.131 SW Horn/Strobe 15 0.066 Temporal, Low 10 65 20.090 P2W Strobe 15 0.066 40 105 19.941 SW Horn/Strobe 15 0.066 Temporal, Low 40 145 19.810 P2W Strobe 75 0.158 20 165 19.753 SW Horn/Strobe 30 0.093 Temporal, Low 25 190 19.706 P2W Strobe 15 0.066 20 210 19.681 SW Horn/Strobe 15 0.066 Temporal, Low 30 240 19.656 P2W Horn/Strobe 15 0.066 Temporal, Low 35 275 19.641 P2W Total current/amps 0.845 Total Dist:275 voltage drop 0.759 8/8/2014 1 SYSTEM `\4 SENSOR' . advanced s,ad./arc r;t als,. Circuit Information Panel Name: FACP (2) amp circuit Circuit Name: NAC CKT 2 Class B @ 14 AWG Starting Voltage: Starting Voltage = 20.4 DC 24 - volt Supply Type and Model Candela Current Tone and Volume Dist from last Dist from 14 device(ft) source(ft) Strobe 15 0.066 35 35 20.088 SW Horn/Strobe 110 0.198 Temporal, Low 25 60 19.875 P2W Strobe 15 0.066 15 75 19.767 SW Strobe 15 0.066 25 100 19.597 SW Horn/Strobe 30 0.093 Temporal, Low 20 120 19.469 P2W Horn/Strobe 15 0.066 Temporal, Low 20 140 19.353 P2W Strobe 177 0.281 25 165 19.218 . SWH Strobe 177 0.281 5 170 19.200 SWH Strobe 177 0.281 25 195 19.155 SWH Total current/amps 1.398 I Total Dist:195 voltage drop 1.245 8/8/2014 2 • OCM,..,‘ STEM SENSOR' - ,ncedi ,cis ced solutolsr Circuit Information Panel Name: FACP (2) amp circuit Circuit Name: NAC CKT 3 Class B @ 14 AWG Starting Voltage: Starting Voltage = 20.4 DC 24 - volt Supply Type and Model Candela Current Tone and Volume Dist from last Dist from source 14 device(ft) (ft) Horn/Strobe 135 0.245 Temporal, High 20 20 20.28( P2WH Strobe 15 0.066 80 100 19.925 SW Horn/Strobe 30 0.093 Temporal, Low 30 130 19.805 P2W Strobe 15 0.066 40 170 19.66E SW Strobe 15 0.066 5 175 19.65: SW Strobe 15 0.066 30 205 19.57E SW Horn/Strobe 30 0.093 Temporal, Low 25 230 19.52; P2W Horn/Strobe 135 0.245 Temporal, High 10 240 19.50E . P2WH Total current/amps 0.940 I Total Dist:240 I voltage drop) 0.891 8/8/2014 3 GameweH S3 Series FIRE CONTROL • r' INSTRUMENTS Control Panel by Honeywell Description Small Analog Addressable Fire Alarm Control Panel The Gamewell-FCI,S3 Series Intelligent Fire Alarm Control Panel provides the latest innovative high-end processing power. It offers a simple, intuitive solution for the small to mid-sized fire alarm applications. In standalone or network configurations, the S3 Series complies with most fire alarm application requirements. It supports either of the following types of networks: • Up to 64 nodes using the 7100 Series panel. y • Up to 122 nodes using the S3 Series or E3 Series® panels. Use either twisted-pair wire or fiber-optic to network panels at a high-speed 625K baud ARCNET network bus. With flexible Boolean logic, intelligent detection, and Ether- net connectivity, this system provides power and versatility that surpasses comparable, small addressable fire alarm systems. S3 Series The basic S3 Series consists of an SLP (Smart Loop Features Panel) main board, LCD-SLP touchscreen display, SLC • Listed per ANSI/UL®Standard 864 9th Edition. loop personality modules, and 7 amp power supply. The SLP provides either one or two SLC loops in Class A or B • Allows one SLC loop(expandable to two loops)that configuration that supports either of the following protocols: supports either System Sensor or Apollo devices in • Up to 318 devices per loop using the System Sensor® Class A or Class B(Style 4,6 or 7). protocol. If you add a second loop module, it increases System Sensor supports up to 318 intelligent the maximum device count to 636 devices. devices and each SLC loop supports the following: • Up to 126 devices per loop using the Apollo protocol. If -up to 159 detectors you add a second loop module,It increases the maxi- up to modules(expandable to 636 maximum mum device count to 252 devices. per panel).). - Apollo supports up to 126 intelligent detectors and Four Class B or two Class A NACs can be wired and syn- modules per SLC(expandable to 252 maximum per chronized using the System Sensor, Cooper-Wheelock, or • panel). Gentex strobes.To retrofit the SLP on the existing audible/ Includes a high resolution(4.3")(10.92 cm)color touch- visual appliances, the on-board Electronic EOL (EEOL) screen display. automatically adjusts to the EOL resistor in the field. • Supports a network system of up to 122 nodes (includes E3 Series®panels)or up to 64 nodes A 4.3" (10.92 cm) color touchscreen display screen shows (includes 7100 Series). the following: • 7.0 amp power supply(120VAC or 240VAC). • Events on the system • Includes four Class B or two Class A built-in Notification • Status of analog addressable devices Appliance Circuits(NAC). Provides selectable System • Complete diagnostic fault codes/messages Sensor, Cooper-Wheelock,or Gentex strobe synchroni- • Five programmable function buttons with LED status for zation. accessibility to the following functions: • Supports up to 32 serial annunciators(LCD, LED-only, -Disable/enable -Trouble Acknowledge LED Switch). -Bypass Output -Alarm Acknowledge -Lamp Test -Custom-defined SIGNALING E3 Series® UL and System Sensor@ are registered trademarks of Honeywell International Inc. UL®is a registered trademark of Underwriters'Laboratories Inc. LISTED fcn pnn' S1869 GAMEWELL-FCI •'""""` 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FCI for their use. ©2013 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9021-60730 Rev.A page 1 of 4 Features (Continued) Optional Accessories • Offers an Ethernet port for programming, a variety of DACT-E3-Dialer system reports, and a FocalPoint Graphic Workstation The Digital Alarm Communication Transmitter sends digital connectivity. signals over telephone lines to the central station. It con- • Provides two fully-programmable Form-C contacts for nects to the SLP through an RS 485 bus. Using the Con- fire, trouble, and supervisory. tact ID format, the DACT-E3 provides a four-digit account • TimeCap-Saves time and date up to 48 hours without code followed by the code/numbers listed below: any power or battery. • Three-digit Event Code • • Automatically adjusts to any NAC End-of-Line Resistor Two digit Group Number • (EOL)value(1k-55k ohm)for legacy audible/visual Three digit Contact Number appliances. All codes are used to provide specific point identification. • Removable display can be used as a remote annunciator. The DACT-E3 is compatible with digital alarm communica • Suitable for pre-action deluge applications. tor receivers (DACRs) that receive the following signaling formats: Application • Contact ID • SIA The S3 Series Fire Alarm and Life Safety System is an • 3+1 • 4+2 easy-to-use intelligent fire alarm solution designed for the For more information, refer to the following data sheets: small to mid-sized buildings. Analog technology delivers DACT-E3 Data Sheet, P/N: 9020-0610 the benefits of a simple system installation, while a user- FML-E3/FSL-E3 Data Sheet, P/N: 9021-60783 friendly interface makes panel operation and system main- RPT-E3-UTP-Network Repeater Card tenance quick and intuitive. The Network Repeater allows the SLP fire control panels to Smart Panel Programming connect to the broadband network from remote locations. It Using Boolean logic programming, the installer may cus- connects to other networked units using unshielded, tomize the system to precisely suit the needs of the build- twisted-pair wiring. The RPT-E3-UTP is available with two ing owner. Auto-programming allows the installer to add-on fiber modules: instantly locate all the devices on the SLC loop. • FML-E3 connects to the network using either 62.5/125 Simple, Intuitive Display micron multi-mode fiber. The front panel display provides a user-friendly interface • FSL-E3 connects to the network using 9/125 micron for the operator's control. A 4.3" (10.922 cm) color touch- single mode fiber. screen displays system status, event details and service For more information, refer to the RPT-E3-UTP Data Sheet, P/N: 9020-0609. modes. On the front of the panel,six LEDs show the follow- ing conditions. LCD-7100-Remote Annunciator • Fire • Silenced The Remote serial display features an 80-character dis- • Hazard (Gas or CO) • AC Power play. The LCD-7100 can be surface or flush-mounted on a • Supervisory • Trouble standard 4-gang electrical box. You can use up to five Five custom programmable switches allow the user quick LCD-7100 remote annunciators per SLP panel. access to common functions specific to the building like For more information, refer to the LCD-7100 Data Sheet, device disable, output bypass and device status. P/N: 9020-0486. Perfect for Retrofits ASM-16-Addressable Switch/LED Module The S3 Series is well-suited for retrofit applications. The There are 16 programmable switches available to perform SLP provides a simple way to upgrade your fire protection any function the application requires. Each ASM-16 switch system. It is designed to be an upgrade solution for the leg- has 3 LEDs fully programmable in red, yellow, and green. acy FCI 7100 and Gamewell 602 Series panels. An added These LEDs can be programmed to operate with a certain feature is the SLP's EEOL. Using EEOL, the installers can button press or operate independently as a status signal automatically identify the EOL for existing audible/visual (e.g. ON, OFF,Activated, etc). appliances. Up to 16 ASM-16 modules can be connected to the SLP Flexibility for Future Growth panel. For more information, refer to the ASM-16 Data The S3 Series can be expanded to add a second SLC loop Sheet, P/N: 9020-0554. without replacing the entire system. Using the RPT-E3- ANU-48-48 LED Driver Unit UTP Network Repeater, you can network up to 64 nodes The ANU-48 provides output for eight remote panel (122 nodes with the ANX node expander) using either switches and 48 remote LEDs for use in a remotely located twisted-pair or fiber-optic. The built-in Ethernet port allows the connection to the Gamewell-FCI's FocalPoint for UL®Listed annunciator enclosure. Up to 16 ANU-48 mod- Graphical Workstation. ules can be connected to the SLP panel. For more infor- mation, refer to the ANU-48 Data Sheet, P/N: 9020-0596. Vegglgot 400040414. MTTMT4 Figure 1 LCD-SLP Display GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 9021-60730 Rev.A page 2 of 4 www.gamewell-fci.com Specifications SLP-BB CABINET BACKBO '4 Device Loops Up to two Class A or B,System Sensor O �42y units,each loop supporting up to 318 S9w device addresses. SLP-BB CABINET 1 Apollo units,each loop supporting up p to 126 device addresses per loop. NAC circuits 4 Class B or 2 Class A(2.OA each circuit), � 6.0 A total NAC Operating Voltage 24 VDC o NAC Minimum Voltage 19.5 VDC @ 20.4 V battery voltage j SLC Loop Circuit Operating Voltage 24 V peak-to-peak Input Voltage120 VAC,60 Hz, 21.50'H 240 VAC 50-60 Hz (6.5532m) Input Current 120 VAC,2.75 amps max. 240 VAC, 1.4 amps max. • O 0,/:0 Aux Power 1(Continuous) 24 VDC nominal at 1.OA Aux Power 2(Resettable) 24 VDC nominal at 1.OA Base Panel Current draw Standby:0.111 amps • Alarm: 0.243 amps ® Operating Temperature 32°-120°F(0°-49°C) Relative Humidity 93%(non-condensing) Battery Charger Voltage +24 VDC g 14.547•D Battery Charger Capac- 55 A/H batteries(cabinet accommo- (1.3859m) ity dates 12 NH batteries) Alarm,Trouble& Supervisory Relay Contacts Form-C,2 amps @ 24VDC(resistive) Cabinet Dimensions: Figure 2 SLP Enclosure SLP-BB Dimensions 14.094•"W x 21.5"H x 4.547"D (35.79 W x 54.61 Hx11.54cm) S3BB-RB Dimensions 19 3/8"W x 19 3/8"H x 4.5"D (49.22 W x 49.22 H x 11.43 D) Supports up to 636 Velociti S3 Series - devices or 252 XP95 devices Fire Alarm Control Panel +7 _• MCS-COF Intelligent-Dud Fire/Carbon Monoxide Networkable up to 122 panels using twisted- , pair wire or fiber-optic /e" 4.. irk ;. ASD-PL2F ASD-LS iZa Photo Detector Laser Detector I sZ IN} AMM-2IF i' '' Mini Monitor Module MM- RIF Dual Irlput/Output Local rev 1 1 FIRA Energy E3 Series r• •+, \ �5 ,, Trip Panel ♦, sw It S A O XI AOM-2RF MS-7AF o m 0 N Ethernet Relay Module Pull Station a <. -i ' . ill LCD-7100 LCD-SLP LCD-E3 w 0 O Remote Color Touchscreen Remote c Q Annunciator Annunciator Annunciator i 0 ~4 GFocalPolnt 111111111i01 .. b....,,,... Workstation ! i }} ASM-16 ANU-48 Laptop LED Switch Control LED Display Driver Programming Figure 3 SLP Panel Configuration i GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 www.gamewell-fci.com 9021-60730 Rev.A page 3 of 4 J Ordering Information Ordering Information (Continued) Part Number Description Part Number Description SLP-BLK SLP addressable FACP in black SLP-BB Accessories enclosure. DACT-E3 Digital Dialer Communicator Requires either an SLC-PM or an Transmitter for the S3 or E3 Series. SLC95-PM for SLC loops. LCD-SLP LCD Color Touchscreen display with SLP-RED SLP addressable FACP with red door five programmable switches. and black SLP-BB backbox. For use with the S3 Series panels. Requires either an SLC-PM or an Remote annunciation requires the E3 SLC95-PM for SLC loops. Series A2 cabinet. SLP-RED-G SLP addressable FACP (E3BB-BA2, E3BB-RA2) 240VAC power supply with red door and RPT-E3-UTP Network repeater card with twisted- black SLP-BB backbox. pair Fiber connections require either Requires either an SLC-PM or an an FML-E3 or an FSL-E3 card. SLC95-PM for SLC loops. FML-E3 Multi-mode fiber optic card for one SLC-PM System Sensor Loop Card- channel on the RPT-E3-UTP. 1 loop used for 159 sensors and 159 FSL-E3 Single-mode fiber optic card for one modules. For use with the SLP-E3 panels only. channel on the RPT-E3-UTP. SLC95-PM Apollo Loop Card-1 loop used for 126 SLP-RB SLP motherboard sensors and modules. For use with the replacement or the For use with the SLP-E3 panels only. retrofit solutions. FLPS-7-RB SLP 120VAC 7A power supply. For use with the replacement or the retrofit solutions. SLP-RETROFIT SLP Retrofit Kit for 7100 B-Slim and IF602 panels. Includes the new door and the mount- ing plate. Requires the following: • SLP-RB • LCD-SLP • SLC-PM/ • FLPS-7-RB SLC95-PM S3BB-RB SLP red cabinet with an inner door for the mounting display behind the • plexiglass. Requires the following: • SLP-RB • LCD-SLP • SLC-PM/ • FLPS-7-RB SLC95-PM LCD-7100 Remote Serial LCD Annunciator ASM-16 Remote Programmable Addressable Switch/LED Module ANU-48 Remote LED Driver Module GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 9021-60730 Rev.A page 4 of 4 www.gamewell-fci.com Gamewell 1100 Series FIRE CONTROL INSTRUMENTS LCD1100 by Honeywell Description Remote Serial LCD Display The LCD-7100 remote serial display provides superior flex- ibility to the 7100 or E3 Series®installations. It features an 80-character display which duplicates all the information on the main display with the exception of menus. r-, The LCD-7100 contains the following function keys: • Alarm Acknowledge • System Reset/Lamp Test • Trouble Acknowledge • System Drill Test i • Signal Silence LCD-7100 A keylock must be placed in the"ON"position to enable the function keys with the exception of the "Trouble Acknowl- edge" key which is used to silence the trouble sounder on Features the LCD-7100. • Listed under UL Standard 864,9th Edition LEDs on the LCD-7100 are: • Alarm • System Silenced • 80-character alphanumeric LCD display • Supervisory • NAC#1 Silenced • System Trouble • NAC#2 Silenced • Full complement of function keys and LEDs • Power Fault • Remote location up to 3,000 feet(914.4 m)away from the control panel Installation • 7100 and E3 Series®will accommodate up to five(5), The LCD 7100 can be surface or flush-mounted on a stan- annunciators dard four-gang electrical box and installed up to 3,000 feet (914.4 m) away from the main control. The 7100 or E3 • Surface or flush-mount on a standard four-gang, Series® control panels can accommodate up to five (5), electrical box remote LCD-7100 annunciators. • Compact,attractive appearance Specifications Operating Voltage: 24 VDC(nominal) Ordering Information Supervisory Current: .012 amp. Alarm Current: .023 amp. Model Description Absolute Maximum LCD-7100 Remote Serial LCD Display Operating Temperature:32°to 120°F(0°to 49°C) Relative Humidity: 0 to 93%max.,non-condensing at 90°F(32°C) An ISO 9000-2000 Company Dimensions: 8 1/4"L x 4 1/2"H x 1 7/8"D City of • scRauNc (21 x 11 x 4.5 cm) 11, Chicago 0 O MEA ApPrwed Oty of LISTED APPROVED Aco..d Clan 1 DENVER O suss 3006578 255-02-E 73000694:231 class 2 Approved E3 Series is a registered trademark of Honeywell International Inc. High Pose GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FCI for their use. ©2007 by Honeywell International Inc. All rights reserved. WWw.gamewell-fci.com 9020-0486 Rev.h1 page 1 of 1 ISI • -••••••••%` TM Gamew�eHl VeIocitiTM Series amisFIRE CONTROL 111:71• ' INSTRUMENTS ASD-PL2F and by Honeywell ASD-PTL2F Description Analog, Addressable Photoelectronic Smoke Sensor The Gamewell-FCI VelocitiTM Series, analog addres- sable plug-in smoke sensors with integral communi- cation provide features that surpass conventional ��� sensors. Sensitivity can be programmed in the con- trol panel software, and is continuously monitored � ~ and reported to the panel. Point ID capability allows each sensor's address to be set, providing exact locations for selective maintenance when the cham- ber contamination reaches an unacceptable level. ASD-PL2F ASD-PTL2F The ASD-PL2F photoelectric sensor's unique optical sensing chamber is engineered to sense smoke pro- Features duced by a wide range of combustion sources. Dual electronic thermistors add 135°F (57°C) fixed-tem- perature thermal sensing on the ASD-PTL2F model. • Sleek, low-profile design. The VelocitiTM Series use a communication protocol • Visual rotary,decimel switch addressing(01-159). that substantially increases the speed of communica- • Built-in functional test switch activated by an external tion between the sensors and certain Gamewell-FCI magnet. analog addressable fire alarm controls. These • Bicolor LEDs flash green whenever the sensor is devices operate in a grouped fashion. If one of the addressed,and light steady red on alarm'. devices in the group has a status change,the panel's • microprocessor stops the group poll and concen- relay, isolator,or sounder bases. trates on the single device. The net effect is a • Low standby current. response speed up to five times greater than earlier • Analog addressable communication. designs. • Stable communication technique with noise immunity. • Optional remote,single-gang LED Indicator(RA400Z). Ordering Information • Suitable for installation in ducts. • Compatible with Gamewell-FCI analog addressable Model Description ASD-PL2F Analog,addressable photoelectronic panels. smoke sensor Note:'Only the red LED is operative in panels that do not operate ASD-PTL2F Analog,addressable photoelectronic smoke in VelocitiTM mode. sensor with thermal sensing An ISO 9001-2000 Company SIGNALING 42) ® MEA 4,21 • LISTED APPROVED Approved 1t 1.3 S1913 3023594 219.02E Vd.VI 07272.0694263 GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1653 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FCI for their use. 02006 Honeywell lntemational Inc. All rights reserved. www.gamewell-fci.com 9020-0617 Rev.E page 1 of 2 Specifications Installation Size: 2.1"(5.1 cm)high x 4.1"(10.4 cm)diameter installed in 3501 base,6.1" ASD-PL2F plug-in sensors use a separate base to simplify installation, service, and maintenance. A diameter installed in ADB-FL(15.5 cm)L base. special tool allows maintenance personnel to plug-in Shipping weight: 5.2 oz.(147 g) Operating and remove sensors without using a ladder. temperature: ASD-PL2F: 3Mount the base on a box which is at least 1.5" (3.8 cm) AS F to 120°F(0°C to 49°C) SD-PTL2F: deep. Suitable mounting base boxes include: 32°F to 100°F(0°C to 38°C) UL-Listed • 4.0"(10.2 cm)square box. velocity range: 0-4000 ft./min. (1,219.2 m/min.), • 3.5"(8.9 cm)or 4.0"(10.2 cm)octagonal box. suitable for installation in ducts. • Single-gang box(except relay or isolator bases). Relative • With 8501 BH or B501 BHT base, use a 4.0"(10.2 cm) humidity: 10-93%(non condensing) square box. Thermal ratings: Fixed-temperature setpoint 135°F(57°C) • With B224RB or B224B1 base,use a 3.5"(8.9 cm)octag- onal box,or a 4.0"(10.2 cm)octagonal or square box. Electrical Specifications NOTE: Because of the inherent supervision provided Voltage range: 15-32 volts DC peak by the SLC, end-of-line resistors are not required. Standby current: (max.avg.):300 pA @ 24 VDC Wiring "T-taps" or branches are permitted for Style 4 (one communication every 5 (Class"B")wiring. seconds with LED enabled) Maximum alarm Sensor Spacing current: 6.5 mA @ 24 VDC(LED)lit). Gamewell-FCI recommends spacing sensors in com- pliance with NFPA 72. In low airflow applications with Bases and Options smooth ceilings, space sensors 30 feet (9.1 m). For specific information regarding sensor spacing, place- ADB-FL: 6.1"(15.5 cm)diameter ment and special applications, refer to NFPA 72. 8501: 4.1"(10.4 cm)diameter B501 BH or Sounder base assembly(B501 BHT 8501 BHT: produces a temporal pattern). Includes B501 base. B224RB Relay Base: Screw terminals: Up to 14 AWG(2.0 mm2) Relay type: Form-C Rating: 2.0A @ 30 VDC resistive; 0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC inductive. Dimensions: 6.2"x 1.2"(15.7 x 3.0 cm) Maximum:25 devices between isolator bases. RA400Z Remote alarm indicator,LED. BCK-200 Black detector covers(box of 10). GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1653 USA•Tel:(203)484-7161 •Fax:(203)484-7118 9020-0617 Rev.E page 2 of 2 www.gamewell-fci.com L� N 1 O cz N _Q 0 cz Q AlLJ O, v < C z ~' ay � 7 0 0. 0 a 3 c ro c 0) ca (0 CL cn N m o .0 '� 0 N C- U) N UUS c0i cz o� a-2 a) co O -C � N .0 o (a cz e N Z cis E V p c U cn c4 p_ O E U 0- 0 cc), c L p E LL 0 o) a . o a O (d � M O ro N 0 3 U Fa L 0 0 .V O — N O O C _0 c0 O N U >, N U) L c0 N> C O -0 V O E O. U U N as— U C -o a c 3 0 0 3 H C ca N U)> rn C)0_0rn o� 0 c orn E CD :2 CD ' co o U Y na) E o C L > "O p N -o0prn N 3 47 (n .N U) LL U 'C C O E N N v O CM E O o U a c_ U N U` 0 U 0 ca E o O ro E N N o C7 .r E U o c0 O Qj O O U E L a) .> N i' 0 0 cnL,., y o a) 0 c N ca 6)E >� N 0 ,LL- O O E a '=p O c< N 1- C O _T C 0 Rf Q O mEao.0 O ' C O t N v 7 r L ++ •� C 0 2 U CL Y _o c CO N N c O 0 c O N * E — U N C} U CD U O 7? NO r O °p a X Q •E- - N U p 2C ccaorn 01 .�C 0 c0 L N ''0 0 p O N N 4 N -D cl thin o A) N ,> U (0 > E c6 O > (n .L.. 'y 0 'Fn 'y LL O C cN7 N Cl) J d > O i0 N a 70 o O X o X N C LL 7 LL af cc -0 . N o% Cl) Q Q Oi _p. O CV C p U C > O c� o13E01ooC, O oQ 0 '3 3 o U a OOoo M U N c o (n (0 r- cl)) cl)) ccl) - p, U) E (n N o Cn in d cn o N iii L i U N p LL U _ze W O d i d ❑ Q a)0 w-0 -i co i N G Q N N N'D V E-- N d W N N Y O ci i d r E N V C 0 O o ¢ o O _ y 5 0 .L Ir h -> c 0 L%> Q) d V r > N 4) E E + Q% N (D f- > CO (a p U :? > � R CL ami E L 00 • z.=_ /CL �/ N40cc 0 0 �a O, v < C z ~' ay � 7 0 0. 0 a 3 c ro c 0) ca (0 CL cn N m o .0 '� 0 N C- U) ,� (n U O L C71 UUS c0i cz o� a-2 a) co O cc o= = a) C -C � N .0 o (a cz e N Z cis E V p c U cn c4 p_ O E U 0- 0 cc), c L p E LL 0 o) a . o a O (d � M O Co M N 0 3 U Fa L c L U 0 .V O — N O O C _0 c0 O N U >, N U) L c0 N> C O -0 V O E O. U U N as— U C -o 3 0 0 3 H C ca N U)> rn C)0_0rn o� 0 c CD :2 CD ' co o U Y na) E o C L > "O p N -o0prn N 3 47 (n ma) U) LL U 'C C O E N N v O CM E O m CD rn N 'O E Q i N" E U (n c° c_ U N U` 0 U 0 ca E o O ro E N N o C7 .r E U o c0 O Qj O O U E L a) .> N i' 0 0 cnL,., o LL N c L M 00 H N- o a) 0 7 0 M p O C 0 N ca Z >� N 0 ,LL- O O E N co p 0 0- N O- (a 7 '=p O c< N 1- C O (� 7 :6 0 0 0 10 ca a) N a) N �cocac�_c 0 Rf Q O mEao.0 0 U)!n E N i C O t N O L C N O ++ •� N y (p >. o -a CU 'O 2 U CL Y _o c CO N N c O 0 c U f6 L ca — U C} U CD U O 7? NO > C a) N a) C N Q •E- - N p 2C ccaorn 74 0 L FD C 5 N H ro N L N ''0 0 p O N N 4 N -D cl thin o A) L CA L O` Q H'in cu=— (n O, v < C z ~' ay � 0 L a o � LUL N m a� LO N co.cD 0 ,-o co M h0 zcu M d (O o z n of cc) o 'T 'o M L N3E m0 v W U J d UJ>> 3 M y b QNNIM F o. C) O 39 r� 1 o Z a O >�?a� C H O o C o o _ U�2¢ N o c r� 0 4 O E c o _ � d 0 0 O C O cdO N N N O v pQU a) UU ma) U U CL Q U Z U z Z Z U Z c 0 O. > >> > > E > E > (n V 'y 'N 'Fn 'y c N Cl) J d 0 0 N 0 70 C!3 C LL C C o13E01ooC, 0 o U a M r N N r- CC� C Cl) co C07 C O U c c d U CC N N 0 O ¢ 0 O O 0 L a o � LUL N m a� LO N co.cD 0 ,-o co M h0 zcu M d (O o z n of cc) o 'T 'o M L N3E m0 v W U J d UJ>> 3 M y b QNNIM F o. C) O 39 r� 1 o Z a O >�?a� C H O o C o o _ U�2¢ N o c r� 0 4 O E c o _ � d 0 0 O rM& rLVelociti'� Series MENTS by Honeywell AMM2F Addressable Description Monitor Module The FCI VelocitiTM Series, addressable monitor module AMM-2F is a single Style B, Class B initiating device circuit (IDC) with a 47KW end-of-line resistor. This module provides an address for any device or group of ---�. devices connected to this circuit on the signaling line circuit (SLC) of the FCI addressable series fire alarm control panel. Any initiating device with normally open (N.O.) dry contacts may be made addressable when -•.... ' connected to the AMM-2F module. The VelocitiTM Series use a communication protocol that AMM-2F substantially increases the speed of communication between the sensors and certain FCI analog addressable fire alarm controls. These devices operate in a grouped Features fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll • Compact size allows easy installation. and concentrates on the single device. The net effect is • Class B, Style B, initiating circuit. response speed up to five times greater than earlier de- • 40 Ohm line resistance for each initiating device signs. circuit. • Connects to any normally open dry contact device. The AMM-2F module can be programmed to provide a • Bicolor LEDs flash green whenever the module wide variety of input functions to the FCI addressable is addressed, and light steady red on alarm.* *Note:Only the red LED is operative in panels that do not oper- series fire alarm control panels. It can be identified as a ate in VelocitiTM mode. manual station, heat detector, plenum detector, waterflow switch, tamper switch, N.O. contact, smoke detector, projected beam smoke detector, sub loop, Specifications remote zone, etc. It can also serve as a remote system silence, system reset, system acknowledge or drill switch. It is even possible to customize its device type to Supervisory current: 375 pA meet specific job requirements. Alarm current: 600 pA Operating temperature: 32°to 120° F(0°to 49°C) The initiating device circuit of the AMM-2F can supporta Relative humidity: 10 to 93%(non-condensing) maximum line resistance of up to 40 ohms allowing the End-of-line Resistance: 47K ohms use of linear heat detection devices. The compact size Dimensions: 1.3" L x 2.5"W x 0.5" D facilitates the installation of the module inside manual (3.3 x 6.4 x 1.3 cm) stations, or mounting boxes of various types of alarm initiating devices. Ordering Information An ISO 9001-2000 Company Model Description SIGNALING AMM-2F Addressable monitor module,single circuit, Style B,Class B ® MEA * 41) y Ir. LISTED APPROVED Approved `) J{ Velocitile and E3 SeriesTm are trademarks of Fire Control Instruments. S1949 3023594 221.03•E VOI.IV 07300-0694:178 GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-Tel:(203)484-7161 -Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FCI for their use. 2006 Gamewell-FCI. All rights reserved. www.gamewell.fci.com 9020-0626 Rev.C page 1 of 1 Gamewell MS-i Series Fc' FIRE CONTROL INSTRUMENTS by Honeywell Description Non-Coded, Manual Fire Alarm Stations The Gamewell-FCI, MS-7 Series manual fire alarm sta- tions are available in a wide variety of configurations. The Stations comply with the Americans with Disabilities Act (ADA) 5-lb. maximum pull force requirement. Operating F R E instructions and Braille text are engraved in the handle.All stations have a key lock/reset which is keyed alike with rtr Gamewell-FCI fire alarm control panels and other manual IyuL DOWN fire alarm stations. MS-7AF Velociti Addressable Station The MS-7AF Velociti®Series addressable station is a dou- ble action station designed for installation in the signaling line circuit of Gamewell-FCI analog addressable control ferarnewen panels. Activation of the station causes its assigned address to register at the control panel.The door contains an LED which flashes green in normal condition and lights MS-7 steady red when the station has been activated.*The sta- tion features screw terminals. Features MS-7ASF Velociti Addressable Station The MS-7ASF Velociti® Series addressable station is a • Addressable stations compatible with all Gamewell-FCI single action station designed for installation in the signal analog addressable fire alarm controls ing line circuit of Gamewell-FCI analog addressable con- trol panels. Activation of the station causes its assigned • Conventional stations suitable for use with any UL® address to register at the control panel.The door contains Listed control panel an LED which flashes green in normal condition and lights steady red when the station has been activated.*The sta- • Both single and double action stations available tion features screw terminals. • Tumbler lock for test and reset keyed alike with The Velociti® Series stations use a communication proto- Gamewell-FCI controls col that substantially increases the speed of communica- tion between the sensors and certain Gamewell-FCI • Surface or semi-flush mounting analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the • Shock and vibration resistant group has a status change, the panel's microprocessor stops the group poll and focuses on the single device.The net effect is response speed up to five times greater than • Stations(MS-7LOB) Listed for outdoor applications earlier designs. • Complies with ADA pull force requirements MS-7 Double Action Station *Only the red LED is operative in panels that do not oper- The MS-7 double action station is used with conventional ate in Velociti mode. fire alarm control panels. It features a set of single pole contacts and screw terminals for connection to an initiating circuit. An ISO 9001-2000 Company Velociti®is a registered trademark of Honeywell International Inc. uxc UL®is a registered trademark of Underwriter's Laboratories Inc. 0<> LEXAN®is a registered trademark of GE Plastics,a subsidiary of General MEA Electric Company. OVed so 67�*MI 07150.0694261 GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FCI for their use. ©2010 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9020-0616 Rev.D page 1 of 2 , MS-7S Single Action Station Specifications The MS-7S single action station is used with conventional fire alarm control panels. It features a set of single pole Material: Lexan® contacts and wire leads for connection to an initiating circuit. Contact Ratings: 0.25 amps. @ 30 VAC/VDC MS-7SP Double Action Station (resistive) The MS-7SP is a double action station similar to the MS-7 Dimensions: 5 5/8" H x 4 1/4"W x 1 1/4" D station, with the additional feature of both English and (14 x 10.1 x 3.2 cm) Spanish instructions molded into the unit. Operating Temperature MS-7LR Dual-action Agent Release Station (MS-7AF, MS-7ASF): 32°to 120° F(0°to 49° C) The MS-7LR is designed for use with the Gamewell-FCI (MS-7LOB): -30°to 150° F(-35°to 66°C) fire alarm control panels with releasing capabilities and Relative Humidity Flex Series releasing systems. It features a set of single (MS-7AF, MS-7ASF): 10 to 93%(non-condensing) pole contacts and screw terminals for connection to an ini- (MS-7LOB): 85%±5%@ 86° ±3.6° tiating circuit. (30°±2° C) Alarm Current: .0030 amp. 0.007 for LED MS-7LRA Agent Release Station with Abort Supervisory Current The MS-7LRA is designed for use with the Gamewell-FCI (MS-7AF,MS-7ASF): .00030 amps. fire alarm control panels with releasing capabilities and Flex Series releasing systems where system abort capabil- ities are required. It consists of an MS-7LR mounted on a Ordering Information plate with an abort switch and LED indicators for system normal, and system activated status. Part Number Description MS-7LOB Double Action Station MS-7 Double action station (Listed for Outdoor Applications) MS-7AF** Velociti addressable double action The MS-7LOB station must be mounted on a Model SB-I/O station backbox. In retrofit applications, the station is UL Listed for MS-7ASF** Velociti addressable single action station use with the WP-10 backbox. It is intended for use with MS-7S Single action station, wire leads conventional control panels and has a set of single pole MS-7SP Double action station, English and contacts and screw terminals. Spanish instructions Mounting MS-7LR Agent release station,dual-action MS-7LRA Agent release station with abort switch, The MS-7 interior stations may be surface mounted or LED indicators, dual-action semi-flush mounted on a standard double-gang, or 4-inch MS-7LOB Double action station, outdoor use (10.2 cm)square electrical box.An optional trim ring (Includes SB-I/O-Indoor/outdoor use (BG12TR)may also be used for semi-flush mounting. backbox) NYC-Plate SB-I/O Indoor/outdoor use backbackbox The NYC-Plate provides the backplate for the manual pull SB-10 Surface backbox station. (See Figure 1). BG12TR Trim ring for semi-flush mount, plastic NY-PLATE NYC backplate for manual pull station **For use with the Gamewell-FCI analog addressable control panels only. FIRE ( PUSH IN f �PUL1D WN� ao9 fiN Q Figure 1 NYC-Plate GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 9020-0616 Rev.D page 2 of 2 www.gamewell-fci.com • *Th, SYSTEM �.. SENSOR Selectable Output '0,ktftI Horns, Strobes, and Horn/Strobes SpectrAlert®Advance selectable-output horns,strobes, and horn/strobes are rich with features guaranteed to p� �� cut installation times and maximize profits. SPECTRANert Grary A. NI IC Features The SpectrAlert Advance series of notification appliances is •Electrically compatible with existing SpectrAlert products designed to simplify installations,with features such as plug in designs,instant feedback messages to ensure correct installation of •Automatic selection of 12-or 24 volt operation at 15 and 15/75 individual devices,and 11 field-selectable candela settings for wall candela and ceiling strobes and horn/strobes. • •Plug-in design •Field selectable candela settings on wall and ceiling units:15,15/75, When installing Advance products,first attach a universal mounting 30,75,95,110,115,135,150,177,185 plate to a four-inch square,four-inch octagon or double-gang •Same mounting plate for wall-and ceiling-mount units junction box.The two-wire mounting plate attaches to a single-gang •Shorting spring on mounting plate for continuity check before junction box. installation Next,connect the notification appliance circuit wiring to the SEMS •Tamper resistant construction terminals on the mounting plate. •Outdoor wall and ceiling products rated from—40°F to 151°F •Design allows minimal intrusion into the back box Finally,attach the horn,strobe or horn/strobe to the mounting plate •Horn rated at 88+dbA at 16 volts by inserting the product's tabs in the mounting plate's grooves.The device will rotate into position,locking the product's pins into the •Rotary switch for horn tone and three volume selections mounting plate's terminals.The device will temporarily hold in place •Outdoor products UL listed to UL 1638(strobe)and UL 464(horn) with a catch until it is secured with a captured mounting screw. outdoor requirements •Outdoor products NEMA 4X rated The SpectrAlert Advance series includes outdoor notification appliances.Outdoor strobes and horn/strobes(two wire and four •Compatible with MDL sync module wire)are available for wall or ceiling.Outdoor horns are available for wall only.All System Sensor outdoor products are rated between minus 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or Agency Listings dry applications. SIGNALING 4 7125-1653186(indoor strobes) MEA 7386-1653187(o,,tdoor strobes) • 7125-,653:,88(horn/strobes, approved O: mei obey) LISTED APPROVED f I 7135-1653:189(horns,chimes) 54011 3023572 MEA452-05-E 55512 53593 SpectrAlert Advance Specifications Architect/Engineer Specifications General SpectrAlert Advance horns,strobes and horn/strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch octagon back box or double-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,SpectrAlert Advance products,when used with the Sync•Circuit"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts;24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC,or full-wave rectified,unfiltered power supply.Strobes and horn/strobes shall have field-selectable candela settings including 15,15/75,30, /5,95,110,115,135,150,177,185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn/Strobe Combination The horn/strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall he approved for fire protective service. The horn/strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal(continuous) pattern.These options are set by a multiple position switch.On four-wire products,the strobe shall be powered independently of the sounder.The horn on horn/strobe models shall operate on a coded or non-coded power supply. Outdoor Products SpectrAlert Advance outdoor horns,strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahrenheit.The products shall be listed for use with a System Sensor outdoor/weatherproof back box with half inch and three-fourths inch conduit entries. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn/strobe models over a single pair of wires.The module shall mount to a 4"A6 x 4"1/26 x 21/2s-inch back box.I he module shall also control two Style Y(class B)circuits or one Style L (class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) K Series Operating Temperature —40°F to 1517(-40`C to 66°C) Humidity Range 10 to 93%non-condensing(indoor products) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 17DC/FWR or regulated 24DC/FWR' Operating Voltage Range' 8 to 17.5 V(12V nominal)or 16 to 33 V(24 nominal) Input terminal wire gauge 12 to 18 AWG Ceiling mount dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Wall mount dimensions(including lens) 5.61 x 4.1W x 2.51)(142 mrn L x 119 rnrn W x 64 mm D) Horn dimensions 5.61x4.7'Wx1.3"D(142mmLx119mmWx33mmD) Wall-mount back box skirt dimensions(BBS-2,BBSW-2) 5.91 x 5.0'W x 2.21)(151 mm L x 128 mm W x 56 mm D) Ceiling-mount back box skirt dimensions(BBSC-2,BBSCW-2) 71-diameter x 2.25"high(180 mm diameter x 57 mm high) Wall-mount weatherproof back box dimensions(SA-WBB) 5.71 x 5.1'W x 2.OT)(145 mm I x 130 mm W x 51 mm D) Ceiling-mount weatherproof back box dimensions(SA-WBBC) 7.1"diameter x 2.0"high(180 mm diameter x 51 mm high) Wall-mount trim ring dimensions(TR-HS,TRW-HS) 5.71 x 4.812"W x 0.35D(146 mm L x 122 W mm x 9 D mm) Ceiling-mount trim ring dimensions(TRC-HS,TRCW-HS) 6.9"diameter x 0.35 high(176 mm diameter x 9 mm high) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time varying power source that is used on some power supply and panel outputs. 2.P,5,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. Ao5-0395-005 N UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts ` Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15* 123 128 66 /1 lemporal High 5/ 55 69 /5 Candela Range 15/75* 142 148 77 81 Temporal Medium 44 49 58 69 30* NA NA 94 96 Temporal Low 38 44 44 48 75* NA NA 158 153 Non-temporal High 57 56 69 75 95* NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 SO 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-wire Horn/Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 13/ 14/ /9 90 10/ 1/6 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-temporal High 141 152 91 100 116 176 201 221 229 Non-temporal Medium 133 145 75 85 102 163 187 707 716 Non-temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 /8 88 103 160 184 202 206 • Temporal Low 129 151 76 86 101 160 184 194 201 Non-temporal High 142 161 103 112 126 181 203 221 229 Non-temporal Medium 134 155 85 95 110 166 189 208 216 Non-temporal I ow 137 154 80 90 105 161 184 207 711 UL Max.Current Draw(mA RMS),2-wire Horn/Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 lemporal High 24S 259 290 29/ lemporal High 21S 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-temporal High 255 270 303 309 Non-temporal High 233 248 275 281 Non-temporal Medium 242 259 293 799 Non-temporal Medium 219 732 262 267 Non-temporal Low 238 254 291 295 Non-temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures,listed candela Horn and Horn/Strobe Output(dBA) ratings must be reduced in accordance with this table. 8-17.5 16-33 24 Volk Nominal Strobe Output(cd) Switch Volts Volts Reverberant Anechoic Listed Candela Candela rating at-40"F Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 15 1 Temporal High 78 78 84 84 88 88 99 98 15/75 Do not use below 32°F 2 Temporal Medium 74 74 80 80 86 86 96 96 30 3 Temporal Low 71 73 76 76 83 80 94 89 75 44 4 Non-temporal High 87 82 88 88 93 92 100 100 9S /0 5 Non-temporal Medium 78 78 85 85 90 90 98 98 110 110• 6 Non-temporal Low 75 75 81 81 88 84 96 92 115 115 7i Coded High 82 82 88 88 93 92 101 101 135 135 8} Coded Medium /8 /8 85 8S 90 90 9/ 98 • 150 150 91 Coded Low 75 75 81 81 88 85 96 92 177 177 'Settings 7,8,and 9 are not available on 2-wire horn/strobe. 185 185 A05-0395-005 SpectrAlert Advance Dimensions * �4.7" 2.5" 6.8' lil�h Dia. 11111111,117.0 1 \• 1\IITjII56I!p) , \ �� Wall-mount horn/strobes Ceiling-mount horn/strobes 7.1' 7.1" 12.25:1 2.0" Dia. 5.°5-_i �2.73�1 i — Dia. I I / \ o o ��� � o. _ .o � 00 0 r `eo02. 5.98". ^ 6.2" Oo ' 0O I t ���� I e ' ' 0 / 1 ...— ii j Co c_ Wall back box skirt Ceiling back box skirt Wall weatherproof back box Ceiling weatherproof back box SpectrAlert Advance Ordering Information Model Description Model • Description Wall Horn/Strobes Ceiling Horn/Strobes(contd.) P2R' 2-wire Horn/Strobe,Standard cd$,Red PC4W 4-wire Horn/Strobe,Standard cd,White P2RH* 2-wire Horn/Strobe,High cd,Red PC4WH 4-wire Horn/Strobe,High cd,White P2RK*" 2-wire Horn/Strobe,Standard cd,Red,Outdoor Ceiling Strobes P2RHK° 2-wire Horn/Strobe,High cd,Red,Outdoor SCR* Strobe,Standard cd,Red P2W* 2-wire Horn/Strobe,Standard cd,White SCRH* Strobe,High cd,Red P2WH* 2-wire Horn/Strobe,High cd,White SCRK° Strobe,Standard cd,Red,Outdoor P4R* 4-wire Horn/Strobe,Standard cd,Red SCRHK" Strobe,High cd,Red,Outdoor P4RH* 4-wire Horn/Strobe,High cd,Red SCW*i Strobe,Standard cd,White P4RK" 4-wire I lorn/Strobe,Standard cd,Red,Outdoor SCWI I*r Strobe,I ligh cd,White P4RHK° 4-wire Horn/Strobe,High cd,Red,Outdoor Horns P4W* 4-wire Horn/Strobe,Standard cd,White HR Horn,Red P4WH* 4-wire Horn/Strobe,High cd,White HRK° Horn,Red,Outdoor Wall Strobes HW Horn,White SR' Strobe,Standard cd,Red Accessories SRH' Strobe,High cd,Red BBS-2 Back Box Skirt,Wall,Red SRK" Strobe,Standard cd,Red,Outdoor BBSW-2 Back Box Skirt,Wall,White SRI IK Strobe,High cd,Red,Outdoor BBSC-2 Back Box Skirt,Ceiling,Red SW* Strobe,Standard cd,White BBSCW-2 Back Box Skirt,Ceiling,White SWH* Strobe,High cd,White TR-HS Trim Ring,Wall,Red Ceiling Horn/Strobes TRW-HS Trim Ring,Wall White PC2R* 2-wire Horn/Strobe,Standard cd,Red TRC-HS Trim Ring,Ceiling,Red PC2RH" 2-wire Horn/Strobe,High cd,Red TRCW-HS Trim Ring,Ceiling,White PC2RK° 2-wire Horn/Strobe,Standard cd,Red,Outdoor Notes: PC2RHK" 2-wire Horn/Strobe,High cd,Red,Outdoor *Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g., PC2W*t 2-wire Horn/Strobe,Standard cd,White P2R-P PC2WI I*' 2-wire I torn/Strobe,I ligh cd,White t Add"-SP"to model number for"FUEGO"marking on cover,e.g.,P2R-SP. PC4R 4-wire Horn/Strobe,Standard cd,Red #"Standard cd,"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd,"refers to strobes that include 135,150,177,and 185 PC4RH 4-wire Horn/Strobe,High cd,Red candela settings. PC4RK 4-wire Horn/Strobe,Standard cd,Red,Outdoor All outdoor units ending in"K"include a weatherproof back box. PC4RHK° 4-wire Horn/Strobe,High cd,Red,Outdoor a Add"-R"to model number for weatherproof replacement device(no back box included). SYSTEM 02008 System Sensor �� /+� 3825 Ohio Avenue•St.Charles,IL 60174 a°d"Rso ran«„s"yet°change�,mmn"°ocemm"ystem „#comm �7� SE�SOR Phone:800-SENSOR2•Fax:630-377-6495 current product mformaton.induringthe latest version ofthis data sheet A05-0395-005.8/08-#2018