Loading...
Report (13) Unit Report For 3T Project: -Untitled109 04/04/2016 Prepared By: Outdoor Unit Parameters Indoor Unit Parameters Unit Model. 25HCE Unit Model. FB4C Unit Size. 3 Tons Unit Size. 36,000 Btuh Voltage. 208/230-1-60 V-Ph-Hz Cabinet Style. TXV Voltage. 208/230-1-60 V-Ph-Hz Heating Size: No Heat Outdoor Unit Dimensions and Weight Indoor Unit Dimensions and Weight Unit Length. 31.1875 in Unit Length. 22.0625 in Unit Width 31.1875 in Unit Wdth17.625 in Unit Height 28.4375 in Unit Height 49.625 in Unit Shipping Weight: 201. lb Unit Shipping Weight 122. lb RESIDENTIALAPPLICATIONS This warranty is to the original purchasing owner and subsequent owners only to the extent and as stated in the Warranty Conditions and below. The limited warranty period in years,depending on the part and the claimant,is as shown in the table below. tflnit+ed"lAiat�attit�r{Years� J: `; r -' :' :lteft1 dginat Own r "i Sub$@tt cent Owner Parts 10*(or 5) 5 Compressor 10*(or 5) 5 *If properly registered within 90 days of original installation,otherwise 5 years(except in California and Quebec and other jurisdictions that prohibit warranty benefits conditioned on registration).See Warranty Conditions below. OTHERAPPUCATIONS The warranty period is five(5)years on the compressor,and one(1)year on all other parts. The warranty is the original owner only and is not available for subsequent owners. Ordering Information Part Number Description Quantity Outdoor Unit 25HCE436A003 Comfort Series Heat Pump with Puron 3 Tons Cooling 1 14 SEER @ ARI Conditions 1 Indoor Unit FB4CNP036L00 FB4C Base Series Fan Coil with Puron 36000 BTU Cooling 1 TXV 1 Aluminum 1 Accessories KFAHD0101 SLP Gasket Kit for Indoor Unit 1 KFCEH2601C10 10 kW Electric Heater with Circuit Breaker for Indoor Unit 1 The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information. Residential Carrier Products Bldr 1.19z Page 2 of 10 Performance Summary For 3T Project: -Untitled109 04/04/2016 Prepared By: System Performance System: 25HCE/FB4C Actual Airflow. 1150.0 CFM System Quantity:.---- - -.---..__ ------ 1 Standard Airflow. 1150.0 CFM Altitude. 0.0 ft Total Net Clg Capacity 32.83 MBH Linear Pipe Length. 0.0 ft Net Sensible Clg Capacity 24.82 MBH COP @ 47 F. 3.62 Htg HP Capacity 33.65 MBH COP @ 17 F: 2.40 Htg HP Integrated Capacity 33.65 MBH SEER @ ARI Conditions: --_... -14.0 Heating HP Compressor Power 2.75 kW EER @ ARI Conditions- 11.7 Total System Power 2.81 kW HSPF @ ARI Conditions. 8.2 System Parameters Outdoor Unit Parameters Indoor Unit Parameters Unit Model. 25HCE436A003 Unit Model. FB4CNP036L00 Unit Size(Nominal). 3 Tons Unit Size(Nominal). 36,000 Btuh Voltage: 208/230-1-60 V-Ph-Hz Voltage. 208/230-1-60 V-Ph-Hz Htg Ent Air DB. 70.0 °F Ent Air DB. 80.00 °F Htg Lvg Air DB• 97.1 °F Ent Air WB. 67.00 °F Clg Ent Air DB Ambient 95.0 °F Ent Enthalpy. 31.44 BTU/lb Htg Ent Air DB Ambient 47.0 °F Lvg Air DB* 60.02 °F Lvg Air WB. 58.10 °F Lvg Enthalpy- 25.09 BTUAb Heating Size(Nominal). No Heat • Indoor Unit External Static: 0.50 in wg Electrical Data Outdoor Electrical Data Indoor Electrical Data: Unit Voltage. 208/230-1-60 V-Ph-Hz (For units with no factory installed electric heaters) Fan Motor FLA• 1.10 Amps Unit Voltage. 208/230-1-60 V-Ph-Hz MCA. 20 Amps Unit FLA. 4.1 Amps Max Fuse. 30 Amps Unit MCA• 5.1 Amps Operating Range Min. 197 V Unit MOCP. 15.0 Amps Operating Range Max- 253 V Unit Min Wre Size' 14.0 Compressor RLA. 15.1 Amps Unit Fuse/Ckt Bkr Amps' 15.0 Amps Compressor LRA. 75.0 Amps Motor HP. 1/2 HP Notice: Indoor Elect data is for 2081230-1-60 voltage Accessory Electric Heater Data (Single point power for unit WITH electric heaters) EH Part Number KFCEH2601C10 Electric Heater kW: 10.0 kW For 2 wire operation (single circuit): Heater Amps. 36.2/40.0 Amps Heater+Motor MCA. 53.8/58.5 Amps Heater+Motor MOCP. 60/60 Amps Accessory Voltage' 208/230-1-60 V-Ph-Hz The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information. Residential Carrier Products Bldr 1.19z Page 3 of 10 Acoustic Summary For 3T Project: -Untitled109 04/04/2016 Prepared By: Outdoor Unit Parameters: Unit Model 25HCE Unit Size: 3 Tons Variations: Standard Octave Band Center Frequency, Hz 63 125 250 500 1k 2k 4k 8k dBA Sound Power,dB 0.0 51.0 62.0 66.0 69.0 64.0 61.0 53.0 A-Weighted Sound Power,dBA 77.0 Indoor Unit Parameters: Unit Model: FB4C Unit Size: 36,000 Btuh Cabinet Style: TXV Octave Band Center Frequency, Hz 63 125 250 500 1k 2k 4k 8k dBA Sound Power,dB 67.8 63.8 59.8 56.8 54.8 52.8 48.8 0.0 A-Weighted Sound Power,dBA 0.0 The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information. Residential Carrier Products Bldr 1.19z Page 4 of 10 -- ---1 Certified Drawing For 3T Project--Untitled109 04/04/2016 Prepared By: ... A -m m so Al,1, DIZIADEE —6 1 HI°MIAMI p•-.1,7.7----.. . _ a 1;4: /. * e:ri. --' ,.''' .... . • ,:///04 :i--4•.,,,,A\ . 1 ill II I I 11 . .= nter _ grift" Ati . FIELD COME 1 II 1 I ,I AIR IA—. law . iy. m11/741 3oPoLi COW. F 8 \\\\V br.e.4117,1 I FIELD AWEA APPLE COn. * ' i III I‘VI' ....! °, '°*.'' I 0 II,IOLI AM 01 118.PIC<PitT kik • di ill ..v.",..-z.„. ;,., I.1 , W I I , LIDAD tiNetor, Nil P lik N4.‘it.,_:..-:::: % 3 IP i5, 1 III II 1 i PAI '-----'• - /-' v ' " t I M7A/NPINIIErldfillIIMM j 1 "4. L i us'— i I t 00 mai 1 i I - T so I 1 — K 1-- I i UK CAA 1.-AR IX X SO it 03cE T,E30.4, 1 ,rx Outdoor Model Unit Model25HCE ::1:MhipplitslOtniehslansiiimt Welithts:'::;:"-:•;:'"---:-:-::':-":-1-:-Outdoor Vat Unit Size 3 Tons Height 33.25 in Voltage- 208/230-1-60 V-Ph-Hz Width 33.38 in SEER' 14 Length 33.38 in PartNumber 25HCE436A003 Operating Weight 170.lb Shipping VVeight 201.lb 31.19 in 28.44 in 3 75 in 0.75 in 6.56 in 24.69 in 9.13 in 2.94 in 0.63 in 1575in 14.00 in 10.75 in The Product and Ratings Data In this program Is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at www.ahrldlrectory.org for the most up-to-date Information. Residential Carrier Products Bldr 1.19z Page 5 of 10 Certified Drawing For 3T Project:-Untitled109 04/04!2016 Prepared By. k IT CC E0 P.S.I ZEEE`, rarE- ._rE iX�ri 6 6 S 17 EWEFT- -.2,t;,4-h°",:.`: i r�Pl,l, x[".+„SITZ>x ron SFirlf Fv.w -1 I.aI E.f Y 1�•DEFr xa.TE ,: v 1 .LL 01.F [ [I.'FLEES'PISCas warpIIIMI FO eta"- ,re• 0. 1,1 ' 1x+tiO. '-•iwE r:,g13Fu°F. :o.R l.1Xc _:- r e,. CCi.TI•CI..T.F -aSrEaluT[ ' y ---- -1K ES.Sr. K[F 1.10 IvOT. n .1 IinT,E. oosIE Sr( F. 4Pf OT , F —1.•. rod , :.LE cMTPofclFIYE C... T3? VIEW '-OPII sin[lai,u:.00i:::: • iX1R.i. 1 1 JK[.,[L u.ili n.Er. _ESE '�---�� '" %YiEL'c _-_�-- -_-� _____ _ W iT l/ uC.Lix[C-0YYEfTtOX . X• rXe o■ / • F ' E 'r AirELcs, .' 1 .0 FI.E CCI.[:11 �373i aE lC+t ]nnx �1 1• T . �_ • . •• H WI moms. 1Ir1 x[cIIXF •y. [i IL , s .[•[ss ,,.r"� F'�' J Fx Ie CPE.Ixs Y.xEL° SLQdE COIL DETAILC ax cines n sxaX . FSS Toa SL0 E CWLS FIGHT SIDE YIE0 IxLET E[ i I Oxs IeHT u11 11.4 [X1 FT Ave—" „F �c[Ls "L -I- FIEi;'IT ElrlYi W.,.•PFLIcri3-.X cO11 CI T•t1.UJ. i osnilaX's1Fa��wrlw�.w;.1: ..P111.l1a.s Indoor Model Unit Model FB4C Dimensions and Weights Indoor Unit Unit Size: 36,000 Btuh Height 49.63 in Voltage 208/230-1-60 V-Ph-Hz Width 17.63 in Cabinet Style: TXV Length 22.06 in Shipping Weight 122.lb Dimensions A C U E F G H d 49.63 in 17.63 in 15.75 in 15.63 in 15.38 in 23.13 in 23.63 in -- 17.00 in The Product and Ratings Data in this program Is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at www.ahridirectory.org for the most up-to-date Information. Residential Carrier Products Bldr 1 19z Page 6 of 10 Certified Drawing For 3T Project:-Untitled109 04!04/2016 Prepared By: !WES. SLOPE ;CIL I CO9DEA3ATE Pik ORAIM CAU NOT SNAR FOR CLttIA 2.ALL DIMENE1LAS ARE 11 llitiet MESS ACBE. Mit T}P. AIRFLDI I I2 P1422219 313FLOR 2 3113.'SI I .2 PLACES2* 1'TF PRIRAR'XAIfi D Q PEICESIA ?Ha. SEf'�tlAO}ORAIY� �� F 911 G PRIMAR7 SOAK- 1 I} ri I I14' 2 22409t}3RAIII-A�i P31►A+t DaAiiF-� ISi 14'-+{ �'' l I nPA Iiii F. *oar NA11,-, 1� t�t � T1P4r ' ' \ }y $EtD1'DAIh P1AIY-� ;.. '1 R ®,. �` 21 'I\ifi l r j ilir3.16' ` 11 1 I S!9' r I 122' I I'T•P, 1114'TIP. F— I2n Ty,I sir Uf' �2�9r14' IF AIAfESb Il;{ACCS:A i 11A" I lie TIP A 1,R' 7;A., 2 he' 2 3 le 3 1,1. I3IIi'�. F T}PI 1,,., T 2 PEA;up. a ONNFLOW H0:.1 LEFT s' ELGw :FIELDCONV'ErTE , HORI7 RIGHT (A5 SHIPPED) IAC SHIPPE i ,FIE[, CONVERTED: Indoor Model Unit Model:_____ FB4C Unit Size: 36,000 Btuh Voltage: 208/230-1-60 V-Ph-Hz The Product and Ratings Data In this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information. Residential Carrier Products Bldr 1.19z Page 7 of 10 Certified Drawing For 3T Project:—Untitled109 04/042016 Prepared By: 1116'TIP. • 101120SIAL PJt"IT LOCt1I01S-MIKES 010112/0 It I9?PLL, 11 RFLP 31 PLICESI IIIFL01 MO lICE OE U331IET,IN CUNEI ODlt r/HOLES PRPIIB 2 VIP TDP. .136'Ilk.It4120tb1 NtKlit 1333 33331 10 OE FIELD StPPLlE0. I I !t PLt roii 0 I'W. {2 PLICESI SKIMP tiAIP-i F 1 UI'--- 6 pump Roil, �, 3 1113' collar @tit Iii0I1 HAM PIMPS.33.13-.{ 113116' 1 �� VIP SECC43tl 08613-3 t TI}r r v .m. II?4 rao-tl/3313 q n mom Inti '� ''\ 1 n r ln. �i iiliAIII! II ,`D(` _ 3"inElj r12 PtAESIf 1 1112• , mem jki 31716' IllS 1311' IfY., S t7!" 2 11113' 11' 1 3f 16' Tiff 2 3/13' ~-4 311• U AL6CESu 1 1/0' 1r.-4 iron 17'a' c2 Plals• DOWNFLNI DPP In'_ HORIl. LEFT (FIELD CONVERTED) NORil. FIGHT 1rP,, ?FLOW IFIELD CONVERTED) IAS SHIPPED) IAS SHIPPED) Indoor Model Unit Model: FB4C Unit Size' 36,000 Btuh Voltage 208/230-1-60 V-Ph-Hz The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at www.ahridirectory.org for the most up4o-date Information. Residential Carrier Products Bldr 1.19z Page 8 of 10 25HCE4 • ComfortT" 14 Heat Pump -~-~ with P'urona Refrigerant Carrier 1-1/2 to 5 Nominal Tons turn to the exports Product Data INDUSTRY LEADING. ° FEATURES i BENEFITS Efficiency 4 ^.{ • 14 SEER.11.5-113F.ER18.2 IISPF • Microtube Thcbnology'"te$%geratioa system * Indoor air quality accessories available Sound •Sound level as low as 69 dl3A •Sound levels as low as 68 dB.Awith accessory sound blanket Comfort •-System supports C&R"'.Edges or standard thermostat controls. Reliability Purone refiigeraat-environmentally sound,won't deplete the ozone layer and low lifetime service cost •Scroll compressor •Internal pr sure relief valve • Internal thermal ovetload Comfort • High switch rtSERIES *Loss of charge switch puro • E R I E * Filler drier' •Balanced refrigeration system for maximum reliability Durability Carrier heat pumps with Purane refrigerant provide a collection of features unmatched by any other family of equipment The• Weatherr�or" proterrion package: 25F CE4 has been designed ntilivinp Carrier's Futon refrigerant_ *Solid.durable street metal constntction. The environmentally sound refrigerant allows consumers to make a •Dense wire coil guard responsible decision in the protection of the earth's axone layer_ +Baked_on powder paint NOTE: Ratings contained in this document are subject to kppiit`8tions change at any time. AlwaysABM refer to' the Adirectory (www ahtidirectorc.orgt for the most up-to-date ratings • Ione-line-ftp to 7.50 feet(76 20 m)total equivalent length up ittfornnation. to 200 feel(60.96 m)condenser above evaporator,or up to 80 ft. (24.38 m)evaporator above condenser(See i onglitte Guide for more information.) •Low ambient(down to-20°F.-28.9C with accessory:'kit. Residential Carrier Products Bldr 1.19z Page 9 of 10 FB4C Base Series Fan Coil tea) Sizes 018 thru 060 turn to the expert Product Data AIR HANDLER TECHN()I1()(sIr AT ITS FINEST w s The FB4C fan coil combines the proven technology of Carrier fan cod units with the flexibility to handle both Futon®refrigerant and R-22,as well as vertical and horizontal applications, The design 40) features contoured condensate pans with rugged drain connections, ,a ?' ensuring that little water is left in the unit at the end of the cooling duty cycle. The lack of standing condensate and corrosion free pans improves IA() and product Ilk. features homeowners • appreciate. • Standard features include grooved copper tubing and louvered aluminum fins. Coil circuiting has also been updated to make the most of all Carrier heat pumps and air conditioners, Units come with solid state fan controls, 1-inch(25mm)thick insulation with R-value of 4.2, multi-speed motors, and fully-wettable coils, Units can accommodate factory- andlar field-installed heaters from 3to30kW. It also should be noted that the unique cabinet design of these fan cods meet new stringent regulations for cabinet air leakage - a requirement of 2%cabinet leakage rate when tested at 1.0 inches of r,14'1 rh`'t,r static pressure. The FB4C fan coil design is loaded with popular features. These fan coils utilize the latest in electronic commutation motor(ECM) technology through the use of high efficiency. multi-tap ECM w , t motors allowing reliable air delivery with increased static pressure. It comes in a pre-painted (taupe metallic)galvanised steel casing and a factory-supplied power plug for ease of installation. ArmorCoat' provides a tin plating of the indoor coil's copper momhairpins. This creates a barrier between the corrosion-causing elements and the coil. The FB4C unit is shipped with a factory-installed Teflon-ring piston (018 thru 048) or a Puron refrigerant TXV(060). • Residential Carrier Products Bldr 1.19z Page 10 of 10 ._._.._� LITERATURE F$.E SUPERSEDE INFO: Converted THE RI7/lf COMPANY from Cumberland to Trane. SPH B-I NISO.C-1 LA CROSSE,WISCONSIN INSTAUATION PRINTED IN U S A Siace The Trans Company hos o policy of continuous produd JANUARY 1976 improvement,it reserves the right to change specifications and design without notice. Supersedes CSPHA-INC-1 November 1974 HEAT PUMP ACCESSORIES RECEIVED APR 7 2016 FOR USE WITH TRANE AND CUMBERLAND HEAT PUMPP I ARD BUDING DIOF V SIGN ELECTRIC HEAT - 6KW FOR USE WITH CBPUA AND BPUA ORDER NO. 465-17-1 465-22-1 The coil/blower units are manufactured To install the optional additional heat- ' % with a standard heating capacity and er proceed as follows on the initial therefore have a specific heater fac- installation. tory installed. See tabulation below. 1. Remove the front panel of the coil/ blower unit. Max. Standard Additional Coil/Blower Allowable Healer Field Inst. Model K.W. K.W. Heater(K.W.) 2. Remove the two screws "B" from 302 15.2 9.2 6.0 mounting plate "A". Refer to 252 15.2 9.2 6.0 Figure 2. One additional heater may be installed in the coil/blower unit as shown in the above tabulation. This additional accessory heater ships as shown in x " - J''t' `> Figure 1. This heater is equipped with • .. a time delay relay. tt' /_���y�l/moi • T ,-v _ "I• Nn. '_` \ ..s FIGURE 2 -. S.,..44*- -r'Cliik4414k, .,, • .. . !.., %Sr , .•A. NiSit, AFI.. , FIGURE 1 -- Accessory 6 KW Electric Heat © THE TRANE CO., 1976 OLD 4 PAYNE f— _� r Heating&Coolin 111 I 11 a. • g I ���� 11 1111111111111 111 ii.a,III �111II111111.2-. o m 111;I� .o2 a. --woo SIIIII 11 Q i-m-i _...... FEATURES W AVAILABLE Nominal sizes are available from 018 COMPONENTS: Includes a suction-tube accumulator that SIZES: through 060 to meet the needs of residen- minimizes the amount of squid refrigerant tial and fight commercial appications. reaching the compressor;a low-pressure switch that stops the compressor if refriger- 2 EFFICIENCY: With SEER of at least 10.0 and HSPF of ant charge is lost;and an intemal compres- 6.8, these heat pump systems provide sor relief valve on all sizes. economy of operation through energy con- III servation.They recover heat for indoor DEFROST Incorporates a defrost relay,defrost timer comfort from outdoor air during the heating CONTROL and low-voltage terminations.The defrost season and,by automatically reversing the BOARD: control is a time/temperature initiationf refrigerant system,remove indoor heat and termination control which includes 3 field- excess humidity during the cooling season. selectable time periods of 30,50,and 90 CERTIFICATION: All models are listed with UL, (U.S. minutes.The control includes built-in 5 minute compressor delay. and Canada),ARI,and CEC. ELECTRICAL Units are offered in 208-230v,single COMPRESSOR: Designed specifically for heat pump duty, RANGE: phase 018 thru 060 sizes and 208-230v with energy efficiency during heating and cooling 3 phase in the 048 and 060 sizes. operation.Each compressor is her- , meticaly sealed against contamination to FAN MOTOR: The totally enclosed fan motor means assure long life and dependable perfor- greater reliability under adverse weather mance and is internally sprung(018-036 - conditions and dependable performance sizes)and externally mounted on rubber for many years.Permanent split capacitor isolators for quiet operation.Continuous MIMI type motors provide more economical compressor operation is approved down to operation. -30°F(-34°C)in the heating mode andOM down to 55°F(12.8°C)in the cooling mode. CABINET: The steel cabinet is protected with a gal- For improved serviceability,all models are CO vanized coating and treated with a layer equipped with a compressor terminal plug. of zinc phosphate.A modified polyester powder coating is then applied and baked SERVICE Both service valves are brass,front seat- on, providing each unit with a hard, VALVES: ung type with sweat connections.Valves are smooth finish that will last for many years. externally located so refrigerant tube con- CC screws on cabinet exterior are coated nections can be made quickly and easily. 111 for a long-lasting, rust-resistant, quality Each valve has a service port for ease of appearance. checking operating refrigerarl pressures. UNIT DESIGN: The copper tube,enhanced sine wave,alu- SERVICEABILTY: One panel provides access to electrical UNI minum fin coil is designed for optimum heat controls.Removal of top gives access to fan transfer.Vertical air discharge carries sound motor,compressor,and condenser coil. and hot condenser air up and away from adjacent patio areas and foliage.The base 0 pan is designed for easy removal of water, • dirt,and leaves. r SS-PH 10-07 NOTES: 1.Allow 30 in.clearance to service side of unit,48 in. 3.Series designation is the 14th position of the unit above unit,6 in.on one side, 12 in.on remaining side, model number. and 24 in.between units for proper airflow. 4.Center of gravity S. 2.Minimum outdoor operating ambient in cooling mode is 55°F max 125°F. I — A • AIR IN AIR f2CHARGE 4 AIR DISCHARGE DISCHARGE DISCHARGE IMENIMINENIIIIIIIIII111111111111111111111 FIELD POWER 3/BIN.DIA • 1 `' SUPPLY CONN , .00 .."...... �`• III�IIJ 7/e IN.DIA HOLE WITH TIEDOWN �/' KNOCKOUTS ''' AIR IN 1111111.11111111111 1 DIN.DIA KNOCKOUT (2)PLACES .F 1111111 AND 1 3/e FIELD DIA KNOCKOUT ����U� CONTROL AIR IN n� � j1'/IJP I�►gDji 11111111111111111111 SUPPLY CONN .������ %/ IIII!I�I■ %/8IN.DIA HOLE ` + .. `I • ��� N - IN.DIA LIQUID ♦�,"` • 4 J P III�IIII■I� 0 ,.. 0 LINECONN AIR 1114111 :: .4. /, K i�■■' =:"i:-�'/ C DISCHARGE AIR IN# _ 8 HL 4 i 4 N l G D DIA LIQUID LINE CONN M 1 1/4, IAF E A93003 DIMENSIONS(IN.) UNIT MINIMUM MOUNTING SIZE SERIES A B C D E F G H J K L M N P PAD DIMENSIONS 018 D,F 22-1/2 29-15/16 3-3/16 5/8 18-1/2 4-1/16 2-3/4 15/16 8-3/16 3-5/8 7/16 9-1/4 10-7/8 11-7/8 22-1/2 X 22-1/2 - 018 E 22-1/2 27-15/16 3-3/16 5/8 18-1/2 4-1/16 2-3/4 15/16 8-3/16 3-5/8 7-16 9-1/4 10-1/2 11-1/2 22-1/2 X 22-1/2 024 D,F 22-1/2 37-15/16 3-3/16 5/8 18-1/2 4-1/16 2-3/4 15/16 8-3/16 3-5/8 7/16 10-1/4 11-1/2 14-1/4 22-1/2 X 22-1/2 - 024 E 22-1/2 27-15/16 3-3/16 5/8 18-1/2 4-1/16 2-3/4 15/16 8-3/16 3-5/8 7/16 9-1/4 10-1/2 11-1/2 22-1/2 X 22-1/2 030 D,E 22-1/2 37-15/16 3-3/16 3/4 18-1/2 4-1/16 2-3/4 15/16 8-3/16 3-5/8 7/16 10-1/4 11-1/2 14-1/4 22-1/2 X 22-1/2 036 D 22-1/2 37-15/16 3-3/16 3/4 18-1/2 4-1/16 2 3/4 15/16 8-3/16 3-5/8 7/16 10-1/4 11-1/2 14-1/4 22-1/2 X 22-1/2 036 E,F 30 27-15/16 3-1/4 3/4 23-1/2 6-1/2 2-3/4 15/16 10 3-5/8 7/16 11-1/4 17-1/2 12-1/4 30 X 30 _ 042 B,C 30 37-15/16 3-1/4 7/8 23-1/2 6-1/2 2-3/4 15/16 10 3-5/8 7/16 12-3/8 17-11/16 15-3/4 30 X 30 048 B,C 30 37-15/16 3-1/4 7/8 23-1/2 6-1/2 2-3/4 15/16 10 3-5/8 7/16 14 15-1/2 15-5/8 30 X 30 060 B,C 30 27-15/16 3-1/4 7/8 23-1/2 6-1/2 2-3/4 15/16 10 3-5/8 7/16 10-5/16 17-1/4 12-3/4 30 X 30 SPECIFICATIONS UNIT SIZE-SERIES 018-D,F/E 024-D,FIE 030-0,E 036-D/E,F Operating Weight(Lb) 123 126 136 127/160 ELECTRICAL Unit Volts—Hertz—Phase 208-230-60-1 208-230-60-1 208-230-60-1 208-230-60-1 Operating Voltage Range 197-253 197-253 197-253 197-253 Unit Ampacity for Wire Sizing(MCA) 12.3/12.0 15.1/14.5 19.0 23.8/22.2 Min Wire Size 60°C Copper(AWG)* 14 14 14 12 Min Wire Size 75°C Copper(AWG)* 14 14 14 12 Max Wire Length 60°C Copper(Ft)t 66 53 41 52/57 1 Max Wire Length 75°C Copper(Ft)t 62 50 39 50/54 Max Branch Circuit Fuse Size(Amps) 20 25 30 35 Compressor Rated Load Amps 9.4/9.2 11.4/11.2 14.1 17.9/16.6 Compressor Locked Rotor Amps 49.0/48.0 61.0 73.0 105.0/86.0 Fan Motor Full Load Amps 0.5 0.5 1.4 1.4 COMPRESSOR AND REFRIGERANT Compressor Type Reciprocating I Scroll/Reciprocating Refrigerant Type R-22 Refrigerant Charge(Lb) 4.38/4.13 5.30/4.38 5.25 5.31/5.63 OUTDOOR COIL AND FAN Coil Face Area(Sq Ft) 9.38/8.67 12.26/10.84 12.26 12.26/12.85 Coil Fins per In.—Rows--Circuits 20-1-2 20/25-1-3 20-1-3 20-1-3 Fan Motor HP 1/12 1/12 1/4 1/4 Fan Motor RPM 1100 1100 1100 1100 Rated Airflow(CFM) 2000/1700 2100/1700 2300 2300/3300 OPTIONAL EQUIPMENT Time-Delay Relay KAATD0101TDR Outdoor Thermostat KHAOT0301 FST Secondary Outdoor Thermostat KHAOT0201 SEC Cycle Protector KSACY0101AAA KAACH1201AAA/ Crankcase Heater KAACH1001AAA KAACH1001AAA Compressor Start Assist— KSAHS1001AAA KSAHS0901AAA/ Capacitor/Relay KSAHS2001AAA KSAHS2101AAA KSAHS0901AAA KSAHS2101AAA Compressor Start PTC KAACS0201PTC KSASH1101COP/ KSASH1101COP KSASH1901CYU Sound Hood KSASH2001BRL KSASH2001BRL KSASH2001BRL KSASH2001BRL TXV Kits(Hard Shutoff)" KSATX0601HSO TXV Kits(RPB) KHATX0201 RPB I KHATX0301 RPB KHATX0401 RPB KHATX0501 RPB High-Pressure Switch KHAHI0101HPS Low-Ambient Pressure Switch KSALA0201R22 MotorMaster®Control 32LT660004(RCD) Ball Bearing Fan Motor HC34GE231 HC40GE232 Filter Drier P504-8083S Evaporator Freeze Thermostat$$ KAAFT0101AAA Isolation Relay$$ KHAIR0101AAA Liquid-Line Solenoid Valve KHALSO401 LLS Thermostat,Auto Changeover, Non-Programmable,°F/°C 2-Stage Heat,1-Stage Cool TSTATPPBHP01-A Thermostat,Auto Changeover, 7-Day Programmable,°F/°C 2-Stage Heat,1-Stage Cool TSTATPPPHP01-A Outdoor Air Temperature Sensor(For Programmable Thermostat) TSTATXXSEN01-B Backplate for Non-Programmable Thermostat TSTATXXBBP01 Backplate for Programmable Thermostat TSTATXXPBP01 Thermostat Conversion Kit(4 to 5 Wire) —10 pack TSTATXXCNV10 See notes on page 4. -3- SPECIFICATIONS Continued UNIT SIZE-SERIES 042-B/C 048-B,C 060-B,C Operating Weight(Lb) 178 189 220 ELECTRICAL Unit Volts—Hertz—Phase 208-230-60-1 208-230-60-1 208-230-60-3 208-230-60-1 208-230-60-3 Operating Voltage Range 197-253 197-253 187-253 197-253 187-253 Unit Ampacity for Wire Sizing(MCA) 33.2/29.3 31.9 19.4 42.7 27.8 Min Wire Size 60°C Copper(AWG)* 8 8 14 6 10 Min Wire Size 75°C Copper(AWG)* 10 10 14 8 10 Max Wire Length 60°C Copper(Ft)t 91/104 97 48 115 82 • Max Wire Length 75°C Copper(Ft)t 56/63 59 46 69 78 Max Branch Circuit Fuse Size(Amps) 50 50 30 60 40 Compressor Rated Load Amps 25.4/22.3 24.4 14.4 33.0 21.1 Compressor Locked Rotor Amps 115.0/127.0 140.0 105.0 165.0 125.0 Fan Motor Full Load Amps 1.4 1.4 1.4 1.4 1.4 COMPRESSOR AND REFRIGERANT Compressor Type Scroll Refrigerant Type R-22 Refrigerant Charge(Lb) 7.00/7.38 7.93 7.93 I 12.00 12.00 OUTDOOR COIL&FAN Coil Face Area(Sq Ft) 18.21 18.21 18.21 12.85 12.85 Coil Fins per In.—Rows—Circuits 20-1-4 20-1-5 20-1-5 20-2-5 20-2-5 Fan Motor HP 1/4 1/4 1/4 1/4 1/4 Fan Motor RPM 1100 1100 1100 1100 1100 Rated Airflow(CFM) 3300 3300 3300 3300 3300 OPTIONAL EQUIPMENT Time-Delay Relay KAATD0101TDR Outdoor Thermostat KHAOT0301 FST Secondary Outdoor Thermostat KHAOT0201SEC Cyde Protector KSACY0101AAA Crankcase Heater KAACH1201AAA KAACH1201AAA Standard KAACH1201AAA Standard Compressor Start Assist— Capacitor/Relay KSAHS1501AAA KSAHS1601AAA N/A KSAHS1601AAA N/A Compressor Start Thermistor—PTC KAACS0201 PTC KAACS0201 PTC N/A KAACS0201 PTC N/A Sound Hood KSASH1901CYL KSASH2001CYL TXV Kits(Hard Shutoff) KSATX0601HSO KSATX0701HSO TXV Kits(RPB) KHATX0501RPB KHATX0601RPB KHATX0701RPB High-Pressure Switch KHAHI0101HPS Low-Ambient Pressure Switch KSALA0201 R22 MotorMaster®Control 32LT660004(RCD) Ball Bearing Fan Motor HC40GE230 Filter Drier(RCD) P504-8163S Evaporator Freeze Thermostat$$ KAAFT0101AAA Isolation Relay$$ KHAIR0101AAA Liquid-Line Solenoid Valve KHALSO401LLS Thermostat,Auto Changeover, Non-Programmable,°F/°C, 1-Stage Heat,1-Stage Cool TSTATPPBHP01-A Thermostat,Auto Changeover, 7-Day Programmable,°F/°C, 1-Stage Heat,1-Stage Cool TSTATPPPHP01-A Outdoor Air Temperature Sensor(For Programmable Thermostat) TSTATXXSEN01-B Backplate for Non-Programmable Thermostat TSTATXXBBP01 Backplate for Programmable Thermostat TSTATXXPBP01 Thermostat Conversion Kit(4 to 5 Wire) —10 pack TSTATXXCNV10 `The ampacity of non-metallic(NM)sheathed cable shall be that 0160°C(140"F)conductors per NEC 1999,Article 336-26.If wire used is other than specified in chart,refer to applicable tables available in 1999 NEC.Copper wire must be used from disconnect to unit. t Length shown is as measured 1 way along the wire path between the unit and the service panel for a voltage drop not to exceed 2%. $ Units may use fuses or circuit breakers(U.S.only). "Capacitor and relay start assist required on 018-036 sizes(reciprocating compressors)when accessory TXV,liquid-line solenoid,or PF1 M coil is applied. tt Consult low-ambient control Installation Instructions for application. N/A—Not Applicable NOTE:Model 042 MCA value is greater than 048 due to U.L.testing. -4- • REFRIGERANT METERING DEVICE AND LINE SET DATA UNIT SIZE-SERIES 018-D,FIE 024-D,F/E 030-D,E 036-D/E,F 042-B/C 048-B,C 060-B,C METERING DEVICE Outdoor Piston Size 40/42 46/52 55 61/57 63 67 76 Indoor Piston Size* 55 61/63 70 78/73 82/80 88 101 Required Subcooling(°F)t 8/10 14/12 14/10 10/9 10/14 12 11 REFRIGERANT LINE CONNECTION DIAMETERS(IN.ID) Liquid Line 3/8 Vapor Line 5/8 5/8 3/4 3/4 7/8 7/8 7/8 REFRIGERANT LINE DIAMETERS(IN.OD) Liquid Line(All Applications) 3/8 Vapor Line(0-50 Ft Line Lengths) 5/8 5/8 3/4 3/4 7/8 7/8 1-1/8 Vapor Line(Long-Line Applications) 3/4 3/4 7/8 7/8 1-1/8 1-1/8 1-1/8 * Piston listed is for any approved coil combination. t Charging subcooling for indoor TXV-type expansion device. U .© C US CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI. SOUND RATING (dBA) UNIT SIZE—SERIES SOUND RATING • 018-D,F/E 80/78 024-D,F/E 78/78 030-13,E 80 036-DIE,F 80/81 042-B,C 80 048-B,C 80 060-B,C 80 OPTIONAL EQUIPMENT USAGE GUIDELINE REQUIRED FOR REQUIRED FOR LOW-AMBIENT APPLICATIONS LONG-LINE APPLICATIONS* ACCESSORY (Below 55°F) (Over 50 Ft) Crankcase Heater Yes Yes Evaporator Freeze Thermostat Yes No Accumulator No No Compressor Start Assist Capacitor and Relay Yes Yes MotorMaster®Control or Yes No Low-Ambient Pressure Switch Wind Baffle See Low-Ambient No Instructions Support Feet Recommended No Liquid-Line Solenoid Valve See Long-Line or No Application Hard Shutoff TXV Guideline Ball Bearing Fan Motor Yes# No For tubing line sets between 50 and 175 ft,refer to the Residential Split-System Long-Line Application Guideline. t Required for low-ambient controller(full modulation feature)and MotorMaster®Control only. —5— OPTIONAL EQUIPMENT DESCRIPTION AND USAGE(Listed Alphabetically) 1. Ball Bearing Fan Motor A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication. SUGGESTED USE:Required on all units where Low-Ambient Controller(full modulation feature)or MotorMaster®Control has been added. 2. Compressor Start Assist—Capacitor/Relay Start capacitor and start relay which gives a"hard"boost to compressor motor at each start-up. SUGGESTED USE:Installations where interconnecting tube length exceeds 50 ft. Installations where outdoor design temperature exceeds 105°F(40.6°C). Replacement installations with hard shutoff expansion valve and a reciprocating compressor. Installations where Liquid-Line Solenoid Valve has been added. Units installed with low-ambient controller. 3. Compressor Start Assist—PTC Solid-state electrical device which gives a soft boost to compressor motor at each start-up. SUGGESTED USE:Installation with marginal power supply. • Replacement installations with rapid pressure balance(RPB)expansion valve on indoor coil. 4. Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles.Improves compressor lubrication on restart and minimizes chance of refrigerant slugging.May or may not include a thermostat control. SUGGESTED USE:When interconnecting tube length exceeds 50 ft. When unit will be operated below 55°F(12.8°C)outdoor air temperature.(Use with low-ambient controller.) All commercial installations. 5. Cycle Protector Solid-state timing device which prevents compressor rapid recycling.Control provides an approximate 5-minute delay after power to the compressor has been interrupted for any reason,including normal room thermostat cycling. SUGGESTED USE:Installations in areas where power interruptions are frequent. Where user is likely to play with room thermostat. All commercial installations. Installations where interconnecting tube length exceeds 50 ft. High-rise applications. 6. Evaporator Freeze Thermostat An SPST temperature actuated switch which stops unit operation when evaporator reaches freeze-up conditions. SUGGESTED USE:All units where Low-Ambient Controller has been added. 7. Fitter Drier—Bi-Flow A device for removing contaminants from refrigerant circulating in a heat pump system:2-direction flow. SUGGESTED USE:All field-connected split-system heat pumps. 8. High-Pressure Switch Auto reset SPST switch activated by refrigerant pressure on high side of refrigerant circuit.Cycles compressor off if refrigerant pressure rises to about 426±7 psig and resets at 320±20 psig.Provides protection against compressor damage due to loss of outdoor airflow.To prevent rapid compressor recycling,Cycle Protector can be used with this switch. • SUGGESTED USE:Installations exposed to very"dirty"outdoor air. Installations where condenser inlet air temperature exceeds 125°F(51.7°C). 9. Isolation Relay An SPDT relay which switches the Low-Ambient Controller out of the outdoor fan motor circuit when the heat pump switches to heating mode. SUGGESTED USE:All heat pumps where Low-Ambient Controller has been added. 10. Liquid-Line Solenoid Valve An electrically operated shutoff valve to be installed at the outdoor or indoor unit(depending on tubing configuration)which stops and starts refrigerant liquid flow in response to compressor operation.Maintains a column of refrigerant liquid ready for action at next compressor operation cycle. Note:Compressor Start Assist—Capacitor/Relay must also be used. SUGGESTED USE:For improved system performance in heat pumps for certain combinations of indoor and outdoor units.Refer to ARI Unitary Directory. In certain long-line applications.Refer to the Residential Split System Long-Line Application Guideline. 11. Low-Ambient Pressure Switch A long life pressure switch which is mounted to outdoor unit service valve.It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits(approximately 100 psigto 225 psig).The control will maintain wonting head pressure at low-ambient temperatures down to 0°F(-17.8°C)when properly installed. SUGGESTED USE:Cooling operation at outdoor temperatures below 55°F(12.8°C). 12. MotorMaster®Control A fan speed control device activated by a temperature sensor.Designed to control condenser fan motor speed in response to the saturated,condensing temperature during operation in cooling mode only.For outdoor temperatures down to—20°F,it maintains condensing temperature at 100°F±10°F. SUGGESTED USE:Cooling operation at outdoor temperatures below 55°F(12.8°C). All commercial installations. 13. Outdoor Air Temperature Sensor A device that allows the temperature at a remote location(outdoors)to be displayed at the thermostat. SUGGESTED USE:All Payne programmable thermostats. 14. Outdoor Thermostat An SPDT temperature-actuated switch which turns on supplemental electric heaters when outdoor air temperature drops below set point. SUGGESTED USE:Heat pump installations with multiple-stage supplemental heaters. 15. Secondary Outdoor Thermostat An SPDT temperature actuated switch which turns on third-stage of supplemental electric heaters when outdoor air temperature drops below the second- stage set point. SUGGESTED USE:Heat pump installations where 3-stage operation of supplemental heaters is desired. 16. Sound Hood Wraparound sound attenuation cover for the compressor.Reduces unit sound level by about 2 dBA. SUGGESTED USE:Unit installed closer than 15 ft to quiet areas—bedrooms,etc. Unit installed between 2 houses less than 10 ft apart. 17. Thermostatic Expansion Valve(TXV)—Bi-Flow A modulating flow control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator.Kit includes valve,adapter tubes,and external equalizer tube.Both hard shutoff and RPB valves are available. SUGGESTED USE:For improved system performance in cooling mode for certain combinations of indoor and outdoor units.Refer to ARI Unitary Directory. 18. Time-Delay Relay An SPST delayrelay which briefly continues operation of the indoor blower motor to provide additional cooling after the compressor cycles off. SUGGESTED USEFor improved efficiency ratings for certain combinations of indoor and outdoor units.Refer to ARI Unitary Directory. —6— L3. COODWa00DOJ OWOOCD00 MNCDCDCDCOWCDNcocococococo0M NONONNNNNNNNNNNNN 000000NOONONNONON NNNO???CONCOCDCOCOCDCOCOCDCO N N r N N N N N N N N N N N N N N N S cOCOCOco(ocOf--cOf�f�CDN-I� t`cocc;66 Ocococci6c6w6Cocorn N:t`N�nnnnN`nrnnrnN-N-N- N-n�t`N:t`rt`N`N`nrN-N`N-N-n NNNpgN8N8NNppNNNSNN8NSN8NN8N8NSN CL 00000OTON?ONN C-'-) CD CO N�NNNNcV NNWNM N.-N�NNNNNNNNNNNWW NNNNNNNNNNNNNNNNN BCk COWC0D.WCC-0. DC�DCOWG?NWODO 1 C.) NNNNNNNNNNNNN NNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNN N:CO CDCO CO CO CD O CO CO OCD CO CO COO N N N N N N N N N N N N N N N N N N r g (� 088800000 000 00008888880000000 00000880000000000 00000008000000800 ?NOCOCDCDCOOWCONNNNNNNCO ---O)CO 0M010 Ln(A(A mOrOrrNOCONMNCINC9M0 COLn00Ln Nf,1,.000D6 0001WMMO CONNNNNNNe'cl"crVVdVVV o000)OOOr601-0, rOrrr x O)OMOO a OM CAOQ)00 ?C)MC0MMC")C7MMCI000OCOCOCi�f COLDCDCOCOCOCOCOCOCOCOCOCOCOCOCOCD NNNNNNNNNNNNNNNNN C0C0 NN C')C`')MMNC0MC0MM MMMM 000000000000000000 O O?cOCDOCONONNCD00 COCO000?00CD0CDCDCD00?CD CO CDOOCDCDOVJCDCOCOCOWCDCDCACO O?V'NOOCDNCOCOCOCD 000COCO? 00 00 00 000 00 000 0000 r CAOCOr OONr NfCVVrNN NrNNNr NNNNr N,-,-N,-NN`-c`4,-,- Nrrrr Ln Ln OLn OnOOLna0L0Lo Cn Ln V MNMMMMMMMMMMM MMMMMMM MMC0C0MC0MMC0M M6M66MCOMMMMC0C06C0MM MMMMMMMMMMMMCOMMMM N?N?N?�?N?NN?N?N??N�aN?N?CV?NNNc 885� S 85�8888 8888880�0088o 888885S88888p8888 8888888888888p8888888888pp88888888 o p p 2 U VO§V' ORO 7&&§§ C8§888888D.NOWOCDOWCD§ VOWNOACOCONOCO§88§88§ VOOOOaOOSN{OONO aN V'O8§8 u/L")LnmNMMMNM NM CO],NMMN C7 ~ ~^^��^^��^^nom CNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNN C") M MMMMC7MC")MMC')MM 000M000MOOOOMOMO00 LtOLfLnOLCOLC)oOLnLCLn Ln Ln OLn OLn O Cn Ln Ln Loin in Loin Ln Ln 00000 Lo Ln O Lou,Ln Lnln Ln Ln OLA Ln O 000no Ln Ln 0000Ln000n 0000000000000000 W ??OON`cOOLnWWnCDM NNMNMMNMMMMNMM MNRNVNM? 60; OMMMNNMNMMMMMMN 00 G W A A COMOmM(n CA ODO 000QDDcnmOCA(no)0)OOO CA OD)OmODiO 6TO6 60)cn666 0MO)m0)OOCA cO6O DM MCA(nM O00000000000000000 Cl) CC Q Z Q (� M} OO O O O O O OO O O O O O O O O O O O O O O O 0 N O N 0 0 0 O O O O O O O 0 0 0 0 O N O O N 0 N N 0 N 0 0000000000000000 0 0 0 0 N N N N N N N N N N N H gE El000000DooIIIIOOD0000D0000011ll000000000000001110000d000000000011o0o00000oo00000oigit 1 Q aLLQ~ 1 CC `o Z O „,,00.0„, 0 0 0 0 0 0 0 8888888888888 088800088088 O O O N O O O O O O O O O O 88888N88N8NN0N0 8$$OONN N N N N N N N N I0000000001 1 I 16666666666666111 1 1 1OOOOOOOOOOOOOO1 1 10006666666666661 160006666666666662,¢ 1 I p. y Q 8 Q z o E 03 gr 8° n o 88N ' 88 8 N 8 N GI1II1ll1I0I11111Ill1IIIll111111111111Ol1111111111111p611111111111111110 E'E rr r 0 OS Cwwwwwwwww wWwwwwwwwwwww wwwwwwwwwwwwww wwwwwwwwwwwwwww wwwwwwwwwwwwwwww ° ZZZZZZZZZmmmmZZZZZZZZZZZmmmmZZZZZZZZZZZZZZmm ¢ZZZZZZZZZZZZZZZm ¢ZZZZZZZZZZZZZZZm T � , Z u.a6 -ZZZZZZzzz Zzzzzzzzzzzz OZZZZZZZZZZZZZZ� ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ 0000000000000000000000000000000000000000000000000000000000000000000000000000000000 0 8<WCODN?R?RciD.8c98 CO+�V(OVDVE8 CO�(COVO.?CD?E.?GOD_SC.8? c982808g538OOc00000DcOO8??3 8NRsN?�e?.p88c9NR?N??sSs��N?F,'S L0n.0 p0p��S0pLn0 p0p p0p0LOn,8SLSp�88 p0pp8p8p ~ N`N`n^^r^fin^NICD NNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNN mAgAcoAAAAMMAMMM A MMco8C09V7?MMco ?V?'V MONCV MNCV NN 0.0.0 NCo NM QM MM ppCCpp tCpp COjM cp cONCDN ccppNNccpp NcC$p NCV NN NCpN Nc� 00Q0¢0 OOW?N 0000 NMNM `'' CO CO C'� M NjM�M? co??M?`''N ?? ?? ????? OOOOet OO OO OOOOO OO OO 000000. 00 OO OOOooOe, m m„eN¢NQommmoom m,*aaN`go'NoommmmCe,m mg 33c�i`c�Mc�ic�iaQ 330^m QQ33c`Q,ar`O)rt et«WL-1 ^me�U33000000¢Qwl-10 ¢dd 4dd QQ� aL�4L�a�7a<0Q0Q00Q0ococo mm co �4paQQ000�0000mmmmmmm a¢QQoo¢ooQoQ�OQQoommmmmcpm §m ZmUmUmciLnmUUVmmZ Z�0mOMcQo�mMmMUUVUmOZ ZUV0Uc mi.nC)C 000000Z Z0000Uc¢Dc%)U)mm00O000Z Z0000,,cQoa)LQmM,,0000UVZ i MaaawwYaaaLiL M 2aaaOOLL.YYaaaatili2 Maaa,OWNi- .ZaaLi2 2aaaaOOOYYaaaaaa2 2aaaaOw0OYYaaaaa2 LI. u_ a��UUUUUUUYYYYwwa dUUUUUUUUUYYYyyLLa dUUVVUUUUUYYYYYYa aUU��UUUUUUYYYYYya � UUU UUU 0000 0C)0c) UUUU 00000 000000 UUUUUU 000o UUUUUU m a c 0 w 0 N W LLN CL u- d NVQ) O u_ pj C W fr 06 0w Ow coo ciS ow U) o o COMBINATION RATINGS Continued ARI STANDARD RATINGS° Cooling Heating SEER High-Temp Low-Temp Factory- Payne Gas Supplied Furnace UNIT SIZE- INDOOR Enhance- Standard Accessory or Accessory SERIES UNIT TC ment Rating TXV TDRt EER TC COP TC COP HSPF *PF1MN(A,B)048 45,000 TDR 10.10 - - 9.10 47,000 3.22 30,600 2.34 7.2 • CC5A/CO5AA060 44,500 NONE 10.00 10.20 10.20 9.10 46,500 3.08 30,200 2.28 7.2 CC5A/CD5AC048 43,500 NONE - 10.00 10.00 9.00 45,000 3.00 30,200 2.24 7.2 CC5A/CD5AW048 44,000 NONE - 10.00 10.00 9.05 46,500 3.12 30,400 2.30 7.2 CD5AA048 44,000 NONE - 10.00 10.00 9.05 46,500 3.12 30,400 2.30 7.2 CE3AA048 44,500 NONE 10.00 10.50 10.50 9.20 46,500 3.16 30,400 2.32 7.2 ' CE3AA060 46,000 NONE 10.00 10.50 10.50 9.45 45,500 3.24 30,400 2.36 7.2 CF5AA048 45,000 NONE 10.00 - - 9.25 44,500 3.06 31,600 2.36 7.1 CK3BA048 44,500 NONE 10.00 10.50 10.50 9.20 46,500 3.18 30,200 2.32 7.2 048-B,C CK3BA060 46,500 NONE 10.00 10.50 10.50 9.45 46,000 3.28 30,400 2.38 7.2 CK5A/CK5BA048 44,500 NONE 10.00 10.50 10.50 9.20 46,500 3.18 30,200 2.32 7.2 CK5A/CK5BA060 45,500 NONE 10.00 10.50 10.50 9.30 47,000 3.20 30,400 2.34 7.2 CK5A/CK5BT048 44,500 NONE 10.00 10.50 10.50 9.20 46,500 3.18 30,200 2.32 7.2 CK5A/CK5BT060 45,500 NONE 10.00 10.50 10.50 9.30 47,000 3.20 30,400 2.34 7.2 CK5A/CK5BW048 44,500 NONE 10.00 10.50 10.50 9.20 46,500 3.18 30,200 2.32 7.2 CK5A/CK5BX060 46,500 NONE 10.00 10.50 10.50 9.45 46,000 3.28 30,400 2.38 7.2 PF1MN(A,B 060 46,000 TDR 10.50 - - 9.15 45,500 3.20 31,000 2.34 7.2 PF1MN(A,B 070 47,500 TDR 10.50 - - 9.45 42,500 3.16 30,800 2.40 7.2 PF1MN(A,B 071 48,000 TDR&TXV 11.50 - - 9.95 45,500 3.36 32,400 2.58 8.0 'PF1MN(A,B)060 55,500 TDR 10.00 - - 8.75 58,000 3.02 38,500 2.28 6.9 CC5A/C 5AA060 53,500 NONE - 10.00 10.00 8.75 56,000 2.82 37,400 2.20 6.8 CC5A/CD5AW060 55,000 NONE - 10.00 10.00 8.90 57,000 2.96 37,600 2.28 7.0 CE3AA060 56,000 NONE 10.00 10.20 10.20 9.10 57,000 3.02 37,400 2.30 6.8 060-B,C CK3BA060 56,000 NONE 10.00 10.20 10.20 9.15 57,000 3.06 37,600 2.32 7.0 CK5A/CK5BA060 54,000 NONE - 10.20 10.20 9.00 56,000 2.92 37,000 2.26 6.8 CK5A/CK5BT060 54,000 NONE - 10.20 10.20 9.00 56,000 2.92 37,000 2.26 6.8 CK5A/CK5BX060 56,000 NONE 10.00 10.20 10.20 9.15 57,000 3.06 37,600 2.32 7.0 PF1MN(A,B)060 55,500 TDR 10.00 - - 8.75 58,000 3.02 38,500 2.28 6.9 PF1 MN(A,B)070 57,000 TDR 10.00 - - 9.10 58,000 3.16 38,000 2.36 7.0 ' Outdoor section/indoor section combination tested in accordance with DOE test procedures for heat pumps.Ratings for other combinations are determined under DOE computer simulation procedures. I- In most cases,only 1 method should be used to achieve TDR function.Using more than 1 method in a system may cause degradation in performance.Use either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR.All Payne furnaces are equipped with TDR. $ Requires hard shutoff TXV;based on computer simulation. " Ratings are net values reflecting the effects of circulating fan heat.Supplemental electric heat is not included. Ratings are based on: Cooling Standard:80°F(27°C)db,67°F(19°C)wb indoor entering air temperature and 95°F(35°C)db air entering outdoor unit. High-Temperature Heating Standard:70°F(21°C)db indoor entering air temperature and 47°C(8°C)db 43°F(6°C)wb air entering outdoor unit. Low-Temperature Heating Standard:70°F(21°C)db indoor entering air temperature and 17°F(-9°C)db,15°F(-10°C)wb air entering outdoor unit. COP -Coefficient of Performance EER -Energy Efficiency Ratio HSPF-Heating Seasonal Performance Factor SEER-Seasonal Energy Efficiency Ratio TC -Total Capacity(Btuh) TDR -Time-Delay Relay TXV -Thermostatic Expansion Valve -8- DETAILED COOLING CAPACITIES* EVAP CONDENSER ENTERING AIR TEMPERATURES°F AIR 85 95 105 115 Capacity Total Capacity Total Capacity Total Capacity Total MBtuhtSyyss MBtuht Syyss MBtuht Syyss MBtuht Sys CFM EWB Total Sens* kW*` Total Sens* kW** Total Sens# kW** Total Sens* kW** PH1OJA018-D, E. F Cutdoor Section With PF1MN(A.B)018 Indoor Section 72 19.12 9.61 1.82 18.31 9.34 1.91 17.21 8.90 2.01 16.03 8.45 2.10 67 17.50 11.90 1.77 16.46 11.45 1.87 15.29 10.95 1.96 14.12 10.46 2.04 525 6311 16.05 11.42 1.75 15.00 10.94 1.83 13.93 10.45 1.91 12.82 9.95 1.99 62 15.71 14.04 1.75 14.71 13.55 1.82 13.68 13.02 1.90 12.66 12.46 1.98 57 15.07 15.07 1.73 14.27 14.27 1.81 13.45 13.45 1.89 12.60 12.60 1.98 72 19.40 10.03 1.87 18.69 9.84 1.97 17.68 9.51 2.07 16.46 9.05 2.17 67 18.02 12.84 1.84 17.00 12.52 1.93 15.76 12.02 2.02 14.52 11.50 2.11 650 6311 16.63 12.42 1.81 15.45 11.92 1.89 14.34 11.43 1.98 13.18 10.93 2.06 62 16.36 15.50 1.81 15.27 14.90 1.89 14.27 14.27 1.98 13.37 13.37 2.07 57 16.03 16.03 1.80 15.16 15.16 1.89 14.28 14.28 1.98 13.37 13.37 2.07 72 19.39 10.08 1.89 18.71 9.93 1.99 17.75 9.61 2.09 16.53 9.17 2.18 67 18.10 13.00 1.85 17.08 12.70 1.94 15.84 12.22 2.03 14.58 11.70 2.13 675 6311 16.73 12.64 1.83 15.56 12.12 1.91 14.39 11.61 1.99 13.23 11.10 2.07 62 16.49 15.73 1.82 15.36 15.14 1.90 14.42 14.42 1.99 13.49 13.49 2.08 57 16.20 16.20 1.81 15.31 15.31 1.90 14.42 14.42 1.99 13.50 13.50 2.08 Multipliers for Determining the Performance With Other Indoor Sections Indoor Cooling Indoor Cooling Section Size Capacity Power Section Size Capacity Power CC5A/CD5AA 018 1.02 1.03 CK5A/CK5BA 018 1.02 1.01 024 1.05 1.03 024 1.05 1.01 CC5A/CD5AW 024 1.05 1.03 CK5A/CK5BW 024 1.05 1.01 CE3AA 024 1.05 1.02 FF1DNA 018 1.00 0.97 CF5AA 024 1.02 1.00 024 1.05 1.00 CK3BA 024 1.05 1.01 PF1MN(A,B) 018 1.00 1.00 - - - 024 1.06 1.02 • PHIOJA0024-D. E. F Outdoor Section With PF1 MN(A,B)024 Indoor Section 72 26.13 13.39 2.39 24.86 12.97 2.55 23.34 12.40 2.71 21.70 11.75 2.87 67 23.73 16.73 2.34 22.22 16.06 2.49 20.77 15.46 2.63 19.42 14.89 2.76 700 63tt 21.65 15.98 2.28 20.33 15.38 2.41 19.05 14.79 2.54 17.76 14.22 2.67 62 21.55 19.95 2.28 20.00 19.12 2.40 18.79 18.46 2.53 17.66 17.66 2.67 57 20.69 20.69 2.25 19.67 19.67 2.39 18.66 18.66 2.53 17.65 17.65 2.67 72 26.54 13.98 2.45 25.31 13.53 2.61 23.74 12.98 2.76 22.10 12.36 2.93 67 24.23 17.74 2.39 22.60 17.08 2.53 21.11 16.47 2.69 19.72 15.89 2.82 800 63tt 22.09 16.94 2.34 21.16 17.07 2.49 20.25 16.72 2.65 18.04 15.15 2.73 62 21.77 21.10 2.33 20.47 20.41 2.46 19.38 19.38 2.61 18.31 18.31 2.75 57 21.51 21.51 2.32 20.43 20.43 2.46 19.39 19.39 2.61 18.32 18.32 2.75 72 26.83 14.43 2.50 25.61 14.12 2.66 24.05 13.55 2.81 22.44 12.98 2.97 67 24.59 18.69 2.44 22.96 18.07 2.58 21.40 17.45 2.74 19.98 16.86 2.88 900 6311 22.52 17.93 2.39 21.01 17.26 2.53 19.65 16.65 2.66 18.27 16.03 2.79 62 22.29 22.29 2.38 21.09 21.09 2.53 19.97 19.97 2.68 18.86 18.86 2.82 57 22.28 22.28 2.38 21.09 21.09 2.53 19.97 19.97 2.68 18.86 18.86 2.82 Multipliers for Determining the Performance With Other Indoor Sections Indoor Cooling Indoor Cooling Section Size Capacity Power Section Size Capacity Power CC5A/CD5AA 024 0.97 0.97 CK5A/CK5BA 024 0.97 0.96 030 0.99 0.99 030 0.99 0.98 CC5A/CD5AW 024 0.97 0.97 CK5A/CK5BW 024 0.97 0.96 030 0.99 0.99 030 0.99 0.98 CE3AA 024 0.98 0.97 FF1DNA 024 0.96 0.96 030 1.00 0.98 030 1.00 0.99 CF5AA 024 0.98 0.98 PF1MN(A,B) 024 1.00 1.00 CK3BA 024 0.97 0.96 030 1.02 1.01 030 0.99 0.98 - - - See notes on page 12. -9- I DETAILED COOLING CAPACITIES* Continued EVAP CONDENSER ENTERING AIR TEMPERATURES°F AIR 85 95 105 115 Capacity Total Capacity Total Capacity Total Capacity Total MBtuhf MBtuht MBtuht MBt h Sys CFM EWB Total Senef kSW* Total Sens* kSWs Total Sens* kW** Total Sens# kV* PH1OJA030-D, E Outdoor Section With PF1MN(A.B)030 Indoor Section 72 32.4 16.4 2.86 30.6 15.8 3.04 28.7 15.1 3.22 26.9 14.5 3.41 67 29.5 21.0 2.78 27.7 20.3 2.95 26.0 19.7 3.12 24.3 19.0 3.29 875 6311 27.3 20.3 2.72 25.6 19.6 2.88 24.0 18.9 3.04 22.2 18.2 3.19 62 26.8 25.3 2.71 25.3 24.5 2.87 23.8 23.6 3.03 22.3 22.3 3.20 57 26.3 26.3 2.69 25.0 25.0 2.86 23.7 23.7 3.03 22.3 22.3 3.20 72 33.1 17.5 2.94 31.2 16.8 3.13 29.2 16.2 3.31 27.3 15.5 3.50 67 30.1 22.8 2.87 28.3 22.1 3.04 26.5 21.4 3.21 24.7 20.7 3.38 1050 6311 27.8 22.0 2.81 26.1 21.3 2.97 24.4 20.6 3.13 22.7 19.8 3.28 62 27.7 27.5 2.80 26.2 26.2 2.97 24.9 24.9 3.14 23.4 23.4 3.32 57 27.6 27.6 2.80 26.2 26.2 2.97 24.8 24.8 3.15 23.4 23.4 3.32 72 33.6 18.6 3.03 31.6 17.9 3.22 29.6 17.3 3.40 27.6 16.6 3.59 67 30.6 24.8 2.95 28.7 24.0 3.13 26.9 23.3 3.30 25.0 22.6 3.47 1250 6311 28.3 23.8 2.89 26.5 23.1 3.06 24.8 22.3 3.22 23.0 21.5 3.38 62 28.7 28.7 2.91 27.3 27.3 3.08 25.8 25.8 3.26 24.3 24.3 3.44 57 28.7 28.7 2.90 27.3 27.3 3.08 25.8 25.8 3.26 24.3 24.3 3.44 Multipliers for Determining the Performance With Other Indoor Sections Indoor Cooling Indoor Cooling Section Size Capacity Power Section Size Capacity Power CC5A/CD5AA 030 0.99 1.00 CK5A/CK5BA 030 0.99 1.00 036 1.04 1.02 036 1.03 1.01 CC5A/CD5AW 030 1.00 1.01 CK5A/CK5BT 036 1.03 1.01 036 1.04 1.02 CK5A/CK5BW 030 0.99 1.00 CE3AA 030 1.01 1.01 036 1.03 1.01 CE3AA 036 1.02 1.02 FF1DNA 030 1.02 1.04 CF5AA 036 1.03 1.02 PF1MN(A,B) 030 1.00 1.00 CK3BA 030 0.99 1.00 036 1.00 1.02 036 1.03 1.01 - - - PH1OJA036-D. E. F Outdoor Section With PF1MN(A.B)036 Indoor Section 72 38.60 19.88 3.62 37.03 19.18 3.86 35.14 18.51 4.10 33.07 17.71 4.34 ' 67 35.24 24.86 3.54 33.42 24.00 3.76 31.38 23.19 3.99 29.45 22.39 4.19 1050 6311 32.36 23.87 3.47 30.50 22.97 3.66 28.70 22.16 3.86 26.90 21.36 4.06 62 31.74 29.49 3.46 29.99 28.57 3.65 28.29 27.63 3.84 26.64 26.64 4.05 57 30.79 30.79 3.42 29.43 29.43 3.62 28.01 28.01 3.83 26.62 26.62 4.05 72 38.97 20.39 3.70 37.43 19.87 3.94 35.65 19.33 4.19 33.61 18.62 4.43 67 35.94 26.38 3.62 34.00 25.45 3.85 31.92 24.70 4.08 29.92 23.88 4.29 1200 6311 33.00 25.25 3.55 31.10 24.41 3.76 29.20 23.58 3.95 27.34 22.75 4.15 62 32.54 31.41 3.54 30.74 30.37 3.75 29.09 29.09 3.95 27.62 27.62 4.17 57 32.05 32.05 3.53 30.57 30.57 3.74 29.09 29.09 3.95 27.62 27.62 4.17 72 39.23 21.00 3.78 37.74 20.59 4.02 35.95 20.05 4.27 34.01 19.51 4.52 67 36.38 27.65 3.70 34.45 26.89 3.93 32.31 26.13 4.15 30.28 25.28 4.38 1350 6311 33.51 26.63 3.63 31.56 25.77 3.85 29.60 24.91 4.04 27.67 24.03 4.24 62 33.16 33.16 3.62 31.58 31.58 3.85 29.99 29.99 4.07 28.43 28.43 4.29 57 33.09 33.09 3.62 31.60 31.60 3.86 30.00 30.00 4.07 28.44 28.44 4.29 Multipliers for Determining the Performance With Other Indoor Sections Indoor Cooling Indoor Cooling Section Size Capacity Power Section Size Capacity Power CC5A/CD5AA 036 1.01 0.98 CK5A/CK5BA 036 1.01 0.98 042 1.01 0.98 042 1.01 0.98 CC5A/CD5AW 036 1.01 0.98 CK5A/CK5BE 042 1.02 0.98 042 1.01 0.99 CK5A/CK5BT 036 1.01 0.98 CE3AA 036 1.00 0.98 042 1.01 0.98 042 1.02 0.98 CK5A/CK5BW 036 1.01 0.98 CF5AA 036 1.01 0.98 PF1MN(A,B) 036 1.00 1.00 CK3BA 036 1.01 0.98 042 1.02 1.00 042 1.01 0.98 - - - See notes on page 12. -10- DETAILED COOLING CAPACITIES* Continued EVAP CONDENSER ENTERING AIR TEMPERATURES°F AIR 85 95 105 115 Capacity Capacity Capacity Capacity Total Total Total Total MBtuhtSys MBtuht s MBtuht Sys MBtuht Sys CFM EWB Total Sens$ kW** Total Sens# kSW" Total Sens$ kW'* Total Sens$ kW" PH1OJA042-B, C Outdoor Section With PF1MN(A,B)042 Indoor Section 72 44.42 22.84 3.94 42.85 22.26 4.32 40.91 21.55 4.74 38.64 20.67 5.21 67 40.69 28.68 3.86 38.80 27.86 4.24 36.83 27.02 4.62 34.85 26.20 5.05 1225 63 37.51 27.58 3.79 35.79 26.78 4.13 34.01 25.98 4.52 32.14 25.14 4.94 62 36.84 34.08 3.76 35.17 33.22 4.11 33.49 32.31 4.50 31.74 31.30 4.93 • 57 35.81 35.81 3.73 34.43 34.43 4.08 33.05 33.05 4.49 31.56 31.56 4.92 72 44.94 23.64 4.02 43.44 23.21 4.40 41.53 22.55 4.82 39.27 21.72 5.29 67 41.40 30.41 3.95 39.50 29.63 4.32 37.44 28.76 4.72 35.38 27.91 5.15 1400 63 38.24 29.23 3.88 36.44 28.43 4.22 34.60 27.61 4.61 32.61 26.72 5.03 62 37.63 36.28 3.86 35.98 35.32 4.21 34.27 34.27 4.61 32.64 32.64 5.04 57 37.14 37.14 3.86 35.70 35.70 4.20 34.25 34.25 4.60 32.65 32.65 5.04 72 45.18 24.35 4.10 43.81 24.05 4.48 41.97 23.48 4.90 39.77 22.74 5.36 67 41.92 32.00 4.03 40.01 31.27 4.40 37.88 30.39 4.82 35.76 29.51 5.24 1575 63 38.82 30.82 3.95 36.94 29.98 4.32 34.98 29.11 4.70 32.96 28.21 5.12 62 38.34 38.34 3.95 36.81 36.81 4.32 35.19 35.19 4.71 33.55 33.55 5.15 57 38.27 38.27 3.95 36.82 36.82 4.32 35.20 35.20 4.71 33.58 33.58 5.15 Multipliers for Determining the Performance Wilh Other Indoor Sections Indoor Cooling Indoor Cooling Section Size Capacity Power Section Size Capacity Power CC5A/CD5AA 042 0.99 0.97 CK5A/CK5BA 042 1.00 0.99 CC5A/CD5AC 048 0.99 0.99 048 1.00 0.98 CC5A/CD5AW 042 0.97 0.97 CKSA/CK5BE 042 1.01 1.00 048 1.00 0.99 CK5A/CK5BT 042 1.01 1.00 CD5AA 048 0.99 0.97 048 1.01 1.00 CE3AA 042 1.01 0.99 CK5A/CK5BW 048 1.01 1.00 048 1.01 0.99 PF1MN(A,B) 042 1.00 1.00 CF5AA 048 1.01 1.00 048 1.03 1.01 CK3BA 042 1.00 0.99 - - - 048 1.01 1.00 PH1OJA048-B. C Outdoor Section With PF1MN(A.B)048 Indoor Section 72 51.2 26.1 4.53 48.8 25.3 4.96 46.4 24.4 5.44 43.7 23.5 5.95 67 46.9 33.8 4.44 44.7 32.9 4.87 42.4 32.0 5.33 40.0 31.0 5.84 1500 63ff 43.7 32.8 4.38 41.6 31.9 4.80 39.4 30.9 5.26 37.0 29.9 5.75 62 43.2 41.0 4.37 41.2 40.0 4.79 39.2 38.8 5.25 37.1 37.1 5.76 57 42.5 42.5 4.35 40.8 40.8 4.78 39.0 39.0 5.25 37.1 37.1 5.76 72 51.5 26.7 4.58 49.1 25.9 5.01 46.6 25.0 5.49 43.9 24.1 6.00 67 47.3 34.8 4.49 45.0 33.9 4.92 42.6 33.0 5.39 40.2 32.0 5.89 1600 63tt 44.0 33.7 4.42 41.8 32.8 4.85 39.6 31.8 5.31 37.2 30.8 5.80 62 43.6 42.3 4.42 41.6 41.1 4.84 39.6 39.6 5.31 37.7 37.7 5.82 57 43.2 43.2 4.41 41.5 41.5 4.84 39.6 39.6 5.31 37.7 37.7 5.82 72 51.8 27.3 4.63 49.4 26.4 5.06 46.8 25.5 5.54 44.1 24.6 6.05 67 47.6 35.8 4.54 45.3 34.9 4.97 42.9 34.0 5.44 40.4 33.0 5.94 1700 63ff 44.2 34.6 4.47 42.1 33.7 4.90 39.8 32.8 5.36 37.4 31.7 5.85 62 44.0 43.4 4.47 42.1 42.0 4.90 40.2 40.2 5.37 38.2 38.2 5.88 57 43.8 43.8 4.46 42.0 42.0 4.90 40.2 40.2 5.37 38.2 38.2 5.88 Multipliers for Determining the Performance With Other Indoor Sections Indoor Cooling Indoor Cooling Section Size Capacity Power Section Size Capacity Power CC5A/CD5AA 060 0.99 0.99 CKSA/CKSBA 048 0.99 0.98 CC5A/CD5AC 048 0.97 0.98 060 1.01 0.99 CC5A/CD5AW 048 0.98 0.98 CK5A/CK5BT 048 0.99 0.98 CD5AA 048 0.98 0.98 060 1.01 0.99 CE3AA 048 0.99 0.98 CK5A/CK5BW 048 0.99 0.98 060 1.02 0.98 CK5A/CK5BX 060 1.03 1.00 CF5AA 048 1.00 0.98 PF1MN(A,B) 048 1.00 1.00 CK3BA048 0.99 0.98 060 1.02 1.02 060 1.03 1.00 070 1.06 1.02 - - - 071 1.07 0.98 See notes on page 12. -11- DETAILED COOLING CAPACITIES* Continued EVAP CONDENSER ENTERING AIR TEMPERATURES°F AIR p 185 Capacity95 Capacity105 p 1115 CaMBtuhf TSottsal MBtuht Sys MBtuTotal MBtuht Total CFM EWB Total Sens# kW'* Total Sens$ kW" Total Sens# kW" Total Sens# kW" PH1 OJA060-B, C Outdoor Section With PF1111N(A.B)060 Indoor Section 72 64.2 32.6 5.73 61.2 31.5 6.25 58.0 30.4 6.83 54.7 29.3 7.46 ' 67 58.6 42.4 5.61 55.8 41.2 6.13 52.8 40.1 6.69 49.7 38.9 7.31 1900 63ff 54.4 41.0 5.53 51.8 39.9 6.04 49.0 38.7 6.60 46.0 37.4 7.19 62 53.7 51.5 5.51 51.3 50.2 6.03 48.7 48.6 6.59 46.3 46.3 7.20 57 53.0 53.0 5.50 50.9 50.9 6.02 48.7 48.7 6.59 46.3 46.3 7.20 • 72 64.5 33.2 5.79 61.4 32.1 6.32 58.1 31.0 6.89 54.9 29.8 7.52 67 58.9 43.4 5.67 56.0 42.2 6.19 53.0 41.0 6.76 49.9 39.9 7.37 2000 63ff 54.7 42.0 5.59 52.0 40.8 6.10 49.1 39.6 6.66 46.2 38.3 7.26 62 54.2 52.8 5.58 51.6 51.3 6.09 49.2 49.2 6.66 46.8 46.8 7.27 57 53.7 53.7 5.57 51.5 51.5 6.09 49.2 49.2 6.66 46.8 46.8 7.28 72 64.8 33.7 5.85 61.6 32.6 6.38 58.4 31.5 6.95 55.0 30.4 7.58 67 59.1 44.4 5.73 56.1 43.2 6.25 53.1 42.0 6.82 50.0 40.8 7.43 2100 63ff 55.0 42.9 5.64 52.1 41.7 6.16 49.4 40.5 6.72 46.3 39.2 7.32 62 54.6 53.9 5.64 52.2 52.1 6.16 49.8 49.8 6.73 47.3 47.3 7.35 57 54.3 54.3 5.63 52.1 52.1 6.16 49.7 49.7 6.73 47.3 47.3 7.35 Multipliers for Determining the Performance With Other Indoor Sections Indoor Cooling Indoor Cooling Section Size Capacity Power Section Size Capacity Power CC5A/CD5AA 060 0.96 0.96 CK5A/CK5BT 060 0.97 0.95 CC5A/CD5AW 060 0.99 0.97 CK5A/CK5BX 060 1.01 0.96 CE3AA 060 1.01 0.97 PF1MN(A,B) 060 1.00 1.00 CK3BA 060 1.01 0.96 070 1.03 0.99 CK5A/CK5BA 060 0.97 0.95 071 1.01 0.92 NOTE:When the required data fall between the published data,interpolation may be performed.Extrapolation is not an acceptable practice. *Detailed cooling capacities are based on indoor and outdoor unit at the same elevation and connected by 25 ft(4.59m)of tubing.If other than 25 ft (4.59m)of tubing is used and/or indoor unit is located above outdoor unit,a slight variation in capacity may occur. f Total and sensible capacities are net capacities.Blower motor heat has been subtracted. $Sensible capacities shown are based on 80°F(27°C)entering air at the indoor coil.For sensible capacities at other than 80°F(27°C),deduct 835 Btuh(245 kW)per 1000 CFM(480 US)of indoor coil air for each degree below 80°F(27°C),or add 835 Btuh(245 kW)per 1000 CFM(480 US)of indoor coil air per degree above 80°F(27°C). **System kW is total of indoor and outdoor unit kilowatts. 11AtTVA rating indoor condition(75°F edb/63°F ewb).All other indoor air temperatures are at 80°F edb. -12- HEAT PUMP HEATING PERFORMANCE INDOOR OUTDOOR COIL ENTERING AIR TEMPERATURES°F AIR -3 7 17 27 37 47 57 67 Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total MBtuht Pwr MBtuht Pwr MBtuht Pwr MBtuht Pwr MBtuht Pwr MBtuht Pwr MBtuht Pwr MBtuht Pwr EDB CFM Total Int kW#Total Int kW$Total Int kW#Total Int kW#Total Int kW#Total Int kW#Total Int kW#Total Int kW* PH1OJA018-11 E. F Outdoor Section With PF1MN(A.B)018 Indoor Section • 525 5.18 4.77 1.16 7.31 6.72 1.25 9.56 8.72 1.34 11.99 10.65 1.44 14.55 13.24 1.54 17.31 17.31 1.66 20.38 20.38 1.81 23.77 23.77 1.97 65 650 5.46 5.02 1.21 7.63 7.01 1.30 9.97 9.09 1.38 12.47 11.07 1.47 15.07 13.71 1,57 17.89 17.89 1.69 21.09 21.09 1.84 24.00 24.00 1.95 675 5.51 5.06 1.22 7.69 7.07 1.31 10.04 9.15 1.39 12.54 11.14 1.48 15.15 13.79 1.58 17.98 17.98 1.69 21.08 21.08 1.83 23.98 23.98 1.94 525 4.69 4.31 1.15 6.85 6.29 1.25 9.09 8.28 1.35 11.56 10.26 1.45 14.07 12.81 1.56 16.82 16.82 1.68 19.86 19.86 1.83 23.30 23.30 2.00 70 650 4.95 4.55 1.20 7.18 6.60 1.30 9.49 8.65 1.39 12.04 10.69 1.49 14.62 13.30 1.59 17.40 17.40 1.71 20.55 20.55 1.85 23,73 23.73 1.98 675 5.00 4.60 1.21 7.23 6.64 1.31 9.56 8.71 1.40 12.12 10.76 1.50 14.70 13.38 1.60 17.51 17.51 1.71 20.63 20.63 1.86 23.70 23.70 1.98 525 4.17 3.84 1.15 6.38 5.87 1.26 8.63 7.87 1.36 11.07 9.83 1.46 13.64 12.41 1.58 16.33 16.33 1.70 19.36 19.36 1.85 22.78 22.78 2.04 75 650 4.42 4.07 1.20 6.70 6.15 1.30 9.00 8.20 1.40 11.56 10.26 1.50 14.13 12.86 1.61 16.92 16.92 1.73 20.04 20.04 1.88 23.35 23.35 2.02 675 4.47 4.11 1.20 6.75 6.20 1.31 9.07 8.27 1.41 11.64 10.33 1.51 14.22 12.94 1,61 17.02 17.02 1.74 20.15 20.15 1.88 23.43 23.43 2.02 Multipliers for Determining the Performance With Other Indoor Sections Indoor Heating Indoor Heating Section Size Capacity Power Section Size Capacity Power CC5A/CD5AA 018 0.98 1.03 CK5A/CK5BA 018 0.98 0.98 024 1.00 1.01 024 1.00 0.96 CC5A/CD5AW 024 1.00 1.01 CK5A/CK5BW 024 1.00 0.96 CE3AA 024 1.00 1.00 FF1DNA 018 1.00 0.98 CF5AA 024 0.98 0.99 024 1.01 0.98 CK3BA 024 1.00 0.96 PF1MN(A,B) 018 1.00 1.00 - - - 024 1.02 0.99 PH10JA024-D. E. F Outdoor Section With PF1 MN(A.B)024 Indoor Section 700 7.73 7.11 1.35 10.26 9.43 1.47 12.98 11.83 1.59 15.94 14.16 1.72 19.23 17.50 1.87 22.88 22.88 2.03 27.02 27.02 2.23 31.20 31.20 2.41 65 800 7.93 7.29 1.38 10.48 9.63 1.50 13.24 12.07 1.62 16.27 14.45 1.75 19.63 17.87 1.89 23.35 23.35 2.04 27.55 27.55 2.22 7.73 7.73 1.35 900 8.11 7.46 1.42 10.68 9.81 1.53 13.47 12.28 1,65 16.55 14.70 1.77 19.97 18,17 1.91 23.74 23.74 2.06 27.72 27.72 2.21 30.76 30.76 2.33 700 7.31 6.73 1.36 9.84 9.04 1.49 12.56 11.45 1.62 15.49 13.75 1.75 18.72 17.04 1.90 22.33 22.33 2.08 26.45 26.45 2.28 30.69 30.69 2.47 • 70 800 7.52 6.91 1.40 10.06 9.24 1.52 12.82 11.69 1.65 15.81 14.04 1.78 19.14 17.41 1.92 22.80 22.80 2.08 26.97 26.97 2.27 30.87 30.87 2.43 900 7.69 7.08 1.43 10.26 9.43 1.55 13.06 11.90 1.67 16.09 14.29 1.80 19.46 17.71 1.94 23.18 23.18 2.10 27.33 27.33 2.27 30.70 30.70 2.40 700 6.88 6.33 1.37 9.41 8.65 1.50 12.13 11.06 1.64 15.05 13.37 1.78 18.26 16.61 1.94 21.80 21.80 2.12 25.86 25.86 2.33 30.18 30.18 2.53 75 800 7.08 6.51 1.41 9.63 8.85 1.54 12.39 11.30 1.67 15.35 13.63 1.81 18.62 16.94 1.96 22.26 22.26 2.13 26.42 26.42 2.33 30.47 30.47 2.49 900 7.25 6.67 1.44 9.83 9.04 1.57 12,62 11.51 1.70 15.62 13.88 1.83 18.94 17.24 1.98 22.64 22.64 2.14 26.85 26.85 2.33 30.41 30.41 2.47 Multipliers for Determining the Performance With Other Indoor Sections Indoor Heating Indoor Heating Section Size Capacity Power Section Size Capacity Power CC5A/CD5AA 024 0.97 0.97 CK5A/CK5BA 024 0.97 0.94 030 0.90 0.91 030 0.90 0.89 CC5A/CD5AW 024 0.97 0.99 CK5A/CK5BW 024 0.97 0.94 030 0.90 0.91 030 0.90 0.89 CE3AA 024 0.97 0.98 FF1 DNA 024 0.97 0.96 030 0.97 0.96 030 0.97 0.95 CF5AA 024 0.97 0.99 PF1MN(A,B) 024 1.00 1.00 CK3BA 024 0.97 0.94 030 1.00 1.00 030 0.90 0.89 - - - See notes on page 16. -13- L HEAT PUMP HEATING PERFORMANCE Continued INDOOR OUTDOOR COIL ENTERING AIR TEMPERATURES°F AIR -3 7 17 27 37 47 57 67 Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total MBtuht Pwr MBtuht Pwr MBtuht Pwr MBtuht Pwr MBtuht Pwr MBtuht Pwr_ MBtuht Pwr MBtuht Pwr EDB CFM Total Int kW#Total Int kW#Total Int kW#Total Int kW# Total Int kW#Total Int kW#Total Int kW#Total Int kW# PH IOJA030-D, E Outdoor Section With PF1 MN(AB)030 Indoor Section 875 11.1 10.2 1.77 14.0 12.9 1.91 17.2 15.7 2.05 20.5 18.2 2.20 24.2 22.1 2.36 28.4 28.4 2.54 33.0 33.0 2.76 38.2 38.2 3.02 65 1050 11.4 10.5 1.83 14.4 13.2 1.96 17.6 16.1 2.10 21.0 18.6 2.24 24.8 22.6 2.39 29.0 29.0 2.56 33.7 33.7 2.77 38.9 38.9 3.03 • 1250 11.8 10.8 1.89 14.8 13.6 2.02 18.0 16.4 2.16 21.4 19.0 2.29 25.2 23.0 2.43 29.5 29.5 2.60 34.3 34.3 2.81 39.5 39.5 3.07 875 10.6 9.76 1.79 13.6 12.5 1.93 16.8 15.3 2.09 20.0 17.8 2.24 23.7 21.6 2.41 27.8 27.8 2.59 32.4 32.4 2.82 37.5 37.5 3.09 • 70 1050 11.0 10.1 1.84 14.0 12.8 1.99 17.2 15.6 2.13 20.5 18.2 2.28 24.3 22.1 2.44 28.4 28.4 2.62 33.1 33.1 2.83 38.2 38.2 3.10 1250 11.3 10.4 1.91 14.3 13.2 2.05 17.6 16.0 2.19 20.9 18.6 2.33 24.7 22.5 2.48 28.9 28.9 2.66 33.6 33.6 2.87 38.8 38.8 3.13 875 10.1 9.29 1.80 13.2 12.1 1.95 16.3 14.9 2.11 19.6 17.4 2.28 23.3 21.2 2.45 27.2 27.2 2.65 31.7 31.7 2.88 36.8 36.8 3.15 75 1050 10.4 9.61 1.86 13.6 12.5 2.01 16.7 15.2 2.16 20.0 17.8 2.31 23.8 21.6 2.48 27.8 27.8 2.67 32.4 32.4 2.89 37.5 37.5 3.16 1250 10.8 9.93 1.92 13.9 12.8 2.07 17.1 15.6 2.22 20.4 18.2 2.37 24.2 22.0 2.53 28.3 28.3 2.71 33.0 33.0 2.93 38.1 38.1 3.19 Multipliers for Determining the Performance With Other Indoor Sections Indoor Heating Indoor Heating Section Size Capacity Power Section Size Capacity Power CC5A/CD5AA 030 0.99 1.01 CK5A/CK5BA 030 0.99 0.99 036 0.98 0.98 036 1.01 0.98 CC5A/CD5AW 030 0.99 1.02 CK5A/CK5BT 036 1.01 0.98 036 0.98 0.98 CK5A/CK5BW 030 0.99 0.99 CE3AA 030 1.01 1.01 036 1.01 0.98 036 1.01 1.00 FF 1 DNA 030 1.01 1.01 CF5AA 036 0.99 0.99 PF1MN(A,B) 030 1.00 1.00 CK3BA 030 0.99 0.99 036 1.02 1.02 036 1.01 0.98 - - - PH10JA436-D. E. F Outdoor Section With PF1MN(A.B)036 Indoor Section 1050 12.13 11.16 2.17 15.89 14.60 2.35 19.96 18.20 2.53 24.24 21.53 2.72 28.94 26.34 2.93 34.07 34.07 3.17 40.0 40.02 3.46 46.42 46.42 3.76 65 1200 12.45 11.46 2.23 16.25 14.93 2.40 20.37 18.57 2.58 24.72 21.95 2.77 29.44 26.79 2.97 34.62 34.62 3.19 40.6.40.62 3.48 46.31 46.31 3.71 1350 12.75 11.73 2.29 16.58 15.24 2.46 20.73 18.90 2.63 25.10 22.29 2.81 29.87 27.18 3.01 35.08 35.08 3.23 40.••40.99 3.49 45.72 45.72 3.67 • 1050 11.50 10.58 2.18 15.29 14.05 2.37 19.35 17.64 2.56 23.64 21.00 2.76 28.34 25.79 2.98 33.45 33.45 3.23 39.2 39.23 3.52 45.95 45.95 3.87 70 1200 11.82 10.87 2.24 15.65 14.38 2.42 19.75 18.01 2.61 24.10 21.41 2.80 28.83 26.24 3.02 34.00 34.00 3.25 39.::39.88 3.55 46.00 46.00 3.81 1350 12.12 11.15 2.30 15.97 14.68 2.48 20.13 18.35 2.66 24.50 21.76 2.85 29.26 26.63 3.06 34.45 34.45 3.29 40.4:40.46 3.59 45.70 45.70 3.78 1050 10.80 9.93 2.19 14.67 13.48 2.39 18.75 17.10 2.59 23.10 20.51 2.80 27.77 25.27 3.03 32.84 32.84 3.29 38.5.38.59 3.60 45.24 45.24 3.97 75 1200 11.13 10.24 2.25 15.02 13.80 2.44 19.16 17.47 2.64 23.54 20.91 2.85 28.25 25.71 3.07 33.38 33.38 3.32 39.17 39.17 3.61 45.63 45.63 3.92 1350 11.42 10.51 2.31 15.35 14.10 2.50 19.52 17.79 2.69 23.94 21.26 2.89 28.66 26.08 3.11 33.84 33.84 3.35 39.76 39.70 3.65 45.52 45.52.3.88 Multipliers for Determining the Performance With Other Indoor Sections Indoor Heating Indoor Heating Section Size Capacity Power Section Size Capacity Power CC5A/CD5AA 036 1.00 0.99 CK5A/CK5BA 036 1.00 0.98 042 1.00 0.99 042 1.01 0.99 CC5A/CD5AW 036 1.00 0.99 CK5A/CK5BE 042 1.01 0.98 042 1.00 1.00 CK5A/CK5BT 036 1.00 0.98 CE3AA 036 1.00 1.00 042 1.01 0.99 042 1.01 0.99 CK5A/CKSBW 036 1.00 0.98 CF5AA 036 0.97 0.96 PF1MN(A,B) 036 1.00 1.00 CK3BA 036 1.00 0.98 042 1.02 1.00 042 1.01 0.99 - See notes on page 16. • • -14- • HEAT PUMP HEATING PERFORMANCE Continued INDOOR OUTDOOR COIL ENTERING AIR TEMPERATURES°F AIR -3 7 17 27 37 47 57 67 Capacity Tl Capacity Total Capacity Capacity Capacity Capacity Capacity Capacity Total MBtuht PwrMBtuhf PwrMBtuht PwrMBtuht PwrMBtuht Pwr MBtuht PwrMBtuhf PwrMuht Pwr EDB CFM Total Int kW$ Total Int kW$Total Int kW$Total Int kW#Total Int kW$ Total Int kW# Total Int kW# Total Int kWf PH10JA042-B. C Outdoor Section With PFTMN(A.B)042 Indoor Section ' 1225 18.02 16.58 2.81 21.94 20.16 2.96 26.23 23.92 3.14 31.05 27.58 3.37 36.46 33.17 3.63 42.48 42.48 3.96 49.4.49.49 4.38 57.66 57.66 4.92 65 1400 18.31 16.84 2.85 22.25 20.44 2.99 26.57 24.23 3.16 31.41 27.90 3.37 36.86 33.54 3.63 42.92 42.92 3.95 50...50.00 4.35 57.88 57.88 4.79 • 1575 18.58 17.09 2.90 22.55 20.72 3.03 26.88 24.51 3.19 31.73 28.18 3.40 37.21 33.86 3.65 43.29 43.29 3.96 50.41 50.41 4.36 57.42 57.42 4.68 1225 17.69 16.28 2.92 21.65 19.89 3.09 25.88 23.60 3.27 30.72 27.28 3.51 36.08 32.83 3.78 42.07 42.07 4.12 48.97 48.97 4.54 57.02 57.02 5.08 f 70 1400 18.01 16.57 2.96 21.95 20.17 3.11 26.24 23.93 3.28 31.07 27.60 3.51 36.48 33.20 3.77 42.50 42.50 4.10 49.49 49.49 4.51 57.59 57.59 5.01 1575 18.26 16.80 3.01 22.24 20.43 3.15 26.55 24.21 3.31 31.40 27.89 3.52 36.83 33.52 3.78 42.89 42.89 4.10 49.91 49.91 4.51 57.50 57.50 4.89 1225 17.33 15.95 3.03 21.35 19.62 321 25.70 23.43 3.41 30.36 26.97 3.65 35.71 32.49 3.93 41.66 41.66 4.29 48.4444 48.44 4.71 56.38 56.38 5.26 75 1400 17.63 16.22 3.07 21.66 19.90 3.24 26.03 23.74 3.42 30.75 27.31 3.65 36.11 32.86 3.92 42.09 42.09 4.26 48.98148.98 4.67 57.03 57.03 5.20 1575 17.91 16.48 3.12 21.93 20.16 327 26.19 23.88 3.44 31.08 27.60 3.67 36.46 33.18 3.93 42.47 42.47 4.26 49.41 49.41 4.67 57.33 57.33 5.13 Multipliers for Determining the Performance With Other Indoor Sections Indoor Heating Indoor Heating Section Size Capacity Power Section Size Capacity Power CC5A/CD5AA 042 1.00 1.00 CK5A/CK5BA 042 0.99 0.98 CC5A/CD5AC 048 0.99 1.03 048 0.99 0.96 CC5A/CD5AW 042 1.00 1.03 CK5A/CK5BE 042 1.00 0.97 048 1.00 0.99 CK5A/CK5BT 042 1.00 0.99 CD5AA 048 0.99 0.98 048 1.00 0.97 CE3AA 042 1.00 0.99 CK5A/CK5BW 048 1.00 0.97 048 1.00 0.98 PF1MN(A,B) 042 1.00 1.00 CF5AA 048 0.99 1.01 048 1.01 0.98 CK3BA 042 0.99 0.98 - - - 048 1.00 0.98 PH10JA048-B. C Outdoor Section With PF1 MN(A.B)048 Indoor Section 1500 26.4 24.2 3.76 30.0 27.5 3.79 33.5 30.6 3.80 37.2 33.0 3.83 40.9 37.2 3.87 45.2 45.2 3.96 50.4 50.4 4.12 53.2 53.2 4.17 • 65 1600 26.5 24.4 3.79 30.1 27.7 3.81 33.7 30.7 3.82 37.4 33.2 3.84 41.1 37.4 3.87 45.5 45.5 3.95 50.6 50.6 4.10 52.8 52.8 4.11 1700 26.7 24.6 3.82 30.3 27.9 3.83 33.9 30.9 3.84 37.6 33.4 3.85 41.3 37.6 3.88 45.7 45.7 3.96 50.8 50.8 4.09 53.2 53.2 4.11 1500 26.0 23.9 3.90 29.6 27.2 3.94 33.2 30.3 3.96 36.8 32.7 3.99 40.5 36.8 4.04 44.7 44.7 4.13 49.9 49.9 4.29 53.6 53.6 4.41 70 1600 26.2 24.1 3.93 29.8 27.4 3.96 33.4 30.5 3.98 37.0 32.9 4.00 40.7 37.0 4.04 45.0 45.0 4.12 50.2 50.2 4.29 53.6 53.6 4.36 1700 26.4 24.3 3.96 30.0 27.6 3.98 33.6 30.6 4.00 37.2 33.1 4.01 40.9 37.2 4.04 45.2 45.2 4.12 50.4 50.4 4.28 53.5 53.5 4.33 1500 25.5 23.4 4.03 29.3 26.9 4.09 32.9 30.0 4.13 36.5 32.4 4.17 40.1 36.5 4.21 44.2 44.2 4.30 49.3 49.3 4.47 53.6 53.6 4.64 75 1600 25.7 23.6 4.06 29.5 27.1 4.12 33.1 30.2 4.14 36.7 32.6 4.17 40.3 36.7 4.21 44.5 44.5 4.29 49.6 49.6 4.46 53.7 53.7 4.60 1700 25.9 23.8 4.09 29.7 27.3 4.14 33.3 30.3 4.16 36.9 32.7 4.18 40.5 36.8 4.22 44.7 44.7 4.29 49.8 49.8 4.45 53.4 53.4 4.54 Indoor Heating Indoor Heating Section Size Capacity Power Section Size Capacity Power CC5A/CD5AA 060 0.99 1.03 CK5A/CK5BA 048 0.99 1.00 CC5A/CD5AC 048 0.96 1.03 060 1.00 1.01 CC5A/CD5AW 048 0.99 1.02 CK5A/CK5BT 048 0.99 1.00 CD5AA 048 0.99 1.02 060 1.00 1.01 CE3AA 048 0.99 1.01 CK5A/CK5BW 048 0.99 1.00 060 0.97 0.96 CK5A/CK5BX 060 0.98 0.96 CF5AA 048 0.95 1.00 PF1MN(A,B) 048 1.00 1.00 CK3BA 048 0.99 1.00 060 0.97 0.97 060 0.98 0.96 070 0.90 0.92 - - - 071 0.97 0.93 See notes on page 16. -15- HEAT PUMP HEATING PERFORMANCE Continued INDOOR OUTDOOR COIL ENTERING AIR TEMPERATURES°F AIR CapacityCapacity Totalp 17ypa 27 67 CapacityCapacityTotal 37 Capacity 47 Total Capacity57 Total Capacity Total MBtuht TotalPwrMBtuht Pwr MBtuht TotalPwrMBtuht TotalPwrMBtuhf PwrMht PwrMBtuht PwrMBtuht Pwr EDB CFM Total Int kW#Total Int kW*Total Int kW*Total Int kW#Total Int kW# Total Int kW#Total Int ,kW*Total Int kW$ PH1 OJA060-B, C Outdoor Section With PF1IVN(A.B)060 Indoor Section 1900 28.0 25.8 4.36 32.8 30.2 4.51 38.2 34.8 4.67 44.0 39.1 4.86 50.9 46.3 5.12 59.4 59.4 5.50 69.7 69.7 6.06 79.0 79.0 6.35 65 2000 28.2 25.9 4.40 33.0 30.4 4.54 38.4 35.0 4.70 44.3 39.3 4.89 51.2 46.6 5.14 59.7 59.7 5.52 70.0 70.0 6.08 78.8 78.8 6.51 2100 28.4 26.1 4.44 33.2 30.5 4.58 38.6 35.2 4.73 44.5 39.5 4.92 51.4 46.8 5.17 59.9 59.9 5.54 70.3 70.3 6.11 78.5 78.5 6.47 1900 27.7 25.5 4.51 32.5 29.8 4.68 37.8 34.4 4.86 43.6 38.7 5.06 50.3 45.8 5.32 58.7 58.7 5.70 68.8 68.8 6.27 78.7 78.7 6.87 70 2000 27.9 25.6 4.55 32.7 30.0 4.71 38.0 34.6 4.88 43.8 38.9 5.08 50.6 46.0 5.34 59.0 59.0 5.72 69.0 69.0 6.28 78.9 78.9 6.85 2100 28.1 25.8 4.59 32.9 30.2 4.75 38.2 34.8 4.91 44.0 39.1 5.11 50.8 46.2 5.36 59.3 59.3 5.74 69.4 69.4 6.31 78.8 78.8 6.82 1900 27.3 25.1 4.66 32.1 29.5 4.85 37.4 34.1 5.05 43.1 38.3 5.26 49.7 45.3 5.53 58.0 58.0 5.92 68.0 68.0 6.49 78.2 78.2 7.16 75 2000 27.5 25.3 4.70 32.3 29.7 4.89 37.6 34.3 5.07 43.3 38.5 5.28 50.0 45.5 5.55 58.3 58.3 5.94 68.3 68.3 6.50 78.4 78.4 7.16 2100 27.7 25.5 4.74 32.5 29.9 4.92 37.8 34.5 5.10 43.6 38.7 5.31 502 45.7 5.57 58.5 58.5 5.95 68.6 68.6 6.52 78.8 78.8 7.19 Multipliers for Determining the Performance With Other Indoor Sections Indoor Heating Indoor Heating Section Size Capacity I Power Section Size Capacity I Power Indoor Heating Indoor Heating Section Size Capacity Power Section Size Capacity Power CC5A/CD5AA 060 0.97 1.03 CK5A/CK5BT 060 0.97 1.00 CC5A/CD5AW 060 0.98 1.00 CK5A/CK5BX 060 0.98 0.97 CE3AA 060 0.98 0.98 PF1MN(A,B) 060 1.00 1.00 CK3BA 060 0.98 0.97 070 1.00 0.96 CK5A/CK5BA 060 0.97 1.00 071 0.97 0.92 NOTE:When the required data fall between the published data,interpolation may be performed.Extrapolation is not an acceptable practice. f The Btuh heating capacity values shown are net integrated values from which the defrost effect has been subtracted.The Btuh heating from supplement heaters should be added to those values to obtain total system capacity. $ The kW values include the compressor,outdoor fan motor,and indoor blower motor.The kW from supplement heaters should be added to these values to obtain total system kilowatts. EDB-Entering Dry Bulb SYSTEM DESIGN 1. Intended for outdoor installation with free air inlet and outlet.Outdoor fan external static pressure available is less than 0.01-in.wc. 2. Minimum outdoor operating air temperature for cooling mode without low-ambient operation accessory is 55°F(12.8°C). 3. Maximum outdoor operating air temperature for cooling mode is 115°F(46.1°C). 4. Minimum outdoor operating air temperature for heating mode is-30°F(-34.4°C). 5. Maximum outdoor operating air temperature for heating mode is 66°F(18.9°C). 6. For reliable operation,unit should be level in all horizontal planes. 7. Maximum elevation of indoor coil above or below base of outdoor unit is:indoor coil above=50 ft,indoor coil below=150 ft.(See items 8 and 9 following.) 8. For interconnecting refrigerant tube lengths greater than 50 ft or 20 ft vertical differential,consult the Residential Split-System Long-Line Appli- cation Guideline available from equipment distributor. 9. IF ANY refrigerant tubing is buried,provide a minimum 6-in.vertical rise to the valve connections at the unit.Refrigerant tubing lengths up to 36 in.may be buried without further consideration.For burial of refrigerant tubing lengths greater than 36 in.,consult local distributor. 10. Use only copper wire for electric connection at unit.Aluminum and clad aluminum are not acceptable for the type of connector provided. • SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE r UNIT MUST BE INSTALLED IN ACCORDANCE PAYNE WITH INSTALLATION INSTRUCTIONS Cancels.SS-PH10-06 Heating&Cool ing ®2003 Payne Heating&Cooling P.O.Box 70,Indianapolis,IN 46206 PRINTED IN U.S.A. Catalog No.52PH-106 09-03 -16-