Loading...
Plans (41) McKinstry 116790 NE Mason St.,Suite 100 I Portland,Oregon ( (503)849-6484 I MC nstry CCB#172811 For fir Of IM•Pilidin J / To: From: Darren Brault Company: ID Experts Pages: RECEIVED ( Phone: Date: 4/05/16 Cell: Re: Ductless system MAY 052016 Scope:Install ductless system in copy room CITY OFTIiGARD Furnish and Install(1)2 ton ductless system with two 12,000 BTU fan coil units install high on the waBIirGD VJSIOI Provide and install(1)condensing unit on the roof up to 15 feet above your space Run refrigeration lines between the fan coil and condensing unit Provide electrical requirements Provide start up and test Provide permits Provide one-year parts and labor warranty Total turnkey project:$14.900.00 Clarifications/Exclusions Any work related to asbestos to be performed by others All work to be performed during normal business hours unless stated differently Structural modifications or structural engineering is not included in this bid Seismic upgrades are excluded HVAC Screens are excluded No other repairs are part of this bid Cutting,patching and paint are excluded New electrical panels or electrical service is excluded New gas meter or water service not included This proposal is valid for 60 days from the date proposed. Upon your favorable review,please sign and return this proposal for scheduling and implementation.Should you have any questions or require additional information, please feel free to call me at 503-849-6484. Sincerely, Darren Brault McKinstry Co. Project Manager Acceptance: Customer Signature P.O. 84. 66e I 16790 NE Mason St.•Suite 100•Portland,OR 97230• (503)331-0234.Oregon California•Colorado•Idaho•Kansas•Minnesota•Montana•Oregon•Texas•Washington•Wisconsin OR CCB Numbers:Electrix,LLC,148685•McKinstry Company,LLC,172811 ■McKinstry Essention,Inc.,168664 MITSUBISHI ELECTRIC in If.S L()M® e Split-ductless A/C and Heat Pumps SUBMITTAL DATA: MXZ-2B2ONA-1 MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM Job Name: ID Experts Location: Lincoln Center Date: 4/22/16 Purchaser: McKinstry Engineer: Submitted to: For ❑Reference 0 Approval ['Construction Unit Designation: ID Experts Copy Room Schedule No.: GENERAL FEATURES Electrical Requirements •Compact side discharge outdoo ,-,V-1:-..---- Power Supply 208/230V,1-Phase,60 Hz Recommended Fuse/Breaker Size 20 A •Wireless or wired remote ° j ( MCA 15 A controller,depending on the " , voltage indoor units used Indoor-Outdoor St-S2 AC 208/230V •Quiet operation—both indoor and ' Indoor-Outdoor S2-S3 DC 12-24V outdoor units •Automatic fan speed control '` OPERATING RANGE •Auto restart following a power m- f outs a "% = Indoor Intake Air Temp. Outdoor Intake Air Temp. •Selfgcheckfunction—integrated •" Cooling Maximum 95°F(35°C)DB,71°F(22°C)WB 115°F(46°C)DB diagnostics Minimum 67°F(19°C)DB.57°F(14°C)WB 14°F(-10°C)DB •Advanced microprocessor control Outdoor Unit:MXZ-2B20NA-1 Maximum 80°F(27°C)DB,67°F(19°C)WB 75°F(24°C)DB,65°F(18°C)WB •Limited warranty:fiveyears onparts and Heating tY Minimum 70°F(21°C)DB,60°F(16°C)WB 6°F(-14°C)DB,5°F(-15°C)wB defects and seven years on compressors OPTIONAL OUTDOOR UNIT ACCESSORIES Compressor DC Inverter-driven Twin Rotary •Air Outlet Guide(MAC-889SG) Fan Motor 0 96 F.L.A. •3/8"x 1/2"Port Adapter(MAC-A454JP;for use with Sound Pressure Level 15,000 Btu/h Indoor units) Cooling(Non-ducted/Ducted) ...49 dB(A) Heating(Non-ducted/Ducted) ..51 dB(A) Cooling" DIMENSIONS INCHES/MM Rated Capacity(Non-ducted/Ducted)...18,000 Btu/h/20,000 Btu/h W 33-1/16!840 Minimum Capacity(Non-ducted/Ducted)..7,800 Btu/h/7,800 Btu/h Total Input(Non-ducted/Ducted) 1 440 W/2,190 W D 13/330 Heating at 47°F' H 27-15/16/710 Rated Capacity(Non-ducted/Ducted)...22,000 Btu/h I 22,000 Btu/h Weight 130 lbs./59 kg Minimum Capacity(Non-ducted/Ducted)..8,500 Btu/h/8,500 Btu/h External Finish Munsell No.3Y 7.8/1.1 Total Input(Non-ducted/Ducted) 1 650 W/1,780 W Heatingat 17°F" Refrigerant Type R410A Refrigerant Pipe Size O.D.—Two Ports Rated Capacity(Non-ducted/Ducted)..12,500 Btu/h/12,500 Btu/h Gas Side A B-3/8"/9.52 mm Total Input(Non-ducted/Ducted) 1 350 W/1,430 W Liquid Side 1/4"/6.35 mm •Rating Conditions(Coding)-Indoor 80°F(27°C)DB/67°F(19°C)WB.Outdoor 95°F(35°C) Max.Refrigerant Pipe Length 164'/50 m DB/75°F(24°C)WB. Max.Piping Length for Each Indoor Unit 82'/25 m (Heating).Indoor 70°F(21°C)os/60°F(16°C)WB.Outdoor:47°F(8°C)DB/43°F(6°C)WB. Max.Refrigerant Pipe ht Difference (Heating at 17°F)-Indoor:70°F(21°C)DB/60°F(16°C)WB.Outdoor 17°F(-8°C)DB/15°F 9 P 9 (-9�)v,B_ If Indoor Unit is Above Outdoor Unit 49'/15 m If Indoor Unit is Below Outdoor Unit 33'/10 m - (For data on specific indoor units[all ducted,all non-ducted,and both ducted Connection Method Flared and non-ducted]combinations,see the Technical and Service Manuals.) COMPATIBLE INDOOR UNITS AND ASSOCIATED REMOTE CONTROLLERS Horizontal-ducted Indoor Units:SEZ-KD09,12,15NA 1 Remote Controller PAR-21MAA- Packaged with SEZ ` -- - MXZ-2B2ONA-1 ENERGY EFFICIENCIES Indoor Unit Type SEER EER HSPF COP @ COP @ GnYP Wall-mounted Indoor Units:MSZ E06,09,12,15NA 47°F 17°F Non ducted 18.0 12.5 8.9 3.91 2.71 wireless Renate Controller- (09+09) Packs ed with MSZ-GE,-FE and ...._ _... a.,.„ MFZMAA(Reonalc Wired -21- Ducted and Non-ducted 16.75 10.8 8.7 3.77 2.64 Ducted 15.5 9.10 8.5 3.62 2.56 Wail-mounted indoor Units: Floor-standing Indoor Units: (09+12) MSZ-FE09,12NA MFZ-KA09,12NA 41P !RR Refer to the separate submittal forms for the SEZ,MSZ,and MFZ indoor Units. MXZ-2B2ONA-1 OPERATION PERFORMANCE • • r • Minimum of two Indoor Units must be connected to the MXZ-2B2ONA-1. • Minimum installed capacity cannot be less than 12,000 Btu/h. • System can operate with only one Indoor Unit turned on(see table below for single Indoor Unit performance). • Indoor Units can be All Non-ducted,All Ducted,or a Combination of Non-ducted and Ducted(Select style as installation requires). • Information provided at 208/230V.Refer to the MXZ Outdoor Unit Service Manual for detailed specifications and additional information per Indoor Unit Combination. Operation Performance for Indoor Unit Cooling Capacity Range(Btulh) Combinations(Unit A+Unit B) Heating Capacity Range(Btuih) Power Usage Range(W) Unit A Unit B Total Range 6 6,000 - 5,400-9,000 490-680 7,400 - 5,200-14.400 480-1,400 9 9,000 - 5,400-9,000 490-750 10,900-11,000 - 5200-15,400 480-1,430 12 12,000 - 5,400-12,000 490-1,010 13,600 - 5,200-16,400 480-1,460 15 15,000 - 5.400-15,000 490-1,560 18,000 - 5,200-21,100 480-2,100 6+6 6,000 6,000 7,800-15,000 510-1,820 7,400 7,400 8.500-25.500 520-2.410 6+9 6,000 9,000 7,800-18,000 630-1,820 7,400 10,900-11,000 8,500-25.500 520-1.400 6+12 6,000 12,000 7,800-20,000 630-1,820 7,400 13,600 8,500-25,500 520-2,520 6+15 5,800 14,200 7,800-23,000 630-2,230 6.400 15,600 8,500-25,500 520-2,520 9+9 9,000 9,000 7,800-20,000 630-1,820 10,900-11.000 10,900-11,000 8,500-25.500 520-2.620 9+12 8,500 11,500 7,800-20,000 630-2,230 9,500 12,500 8,500-25,500 520-2,620 9+15 7,500 12,500 7,800-23,000 630-2,230 8,250 13.750 8,500-25,500 520-2,620 12+12 10,000 10,000 7,800-23,000 630-2,230 11,000 11.000 8,500-25,500 520-2,620 DIMENSIONS: MXZ-2B2ONA-1 ' 6-9/16' 19.11/16• 6-21/32• Unit inch 2-1/2" 111111 nn T. t IIV'^— 'i:=— Soo AY60*.O IF— a a I In 340'516•)Dreln Hole11. 111111111.11111110 13/32.13/16.Oval Hole (Foundation Bolt MI0) 33-1/16• 1-3/18" 1-3/16" 13• 1/2 1 leemmal lie IIIIIIIIII!!"ml,l!h ;!I!IIIIIIIIIIz uIII!I ll I mullluuuuii;Iluu IhIJI!!IIIIIIIIIIIIIIIIIIIIIIVII '// 2 2, imlluilll l!;Irlluuuuu!,Ir 2-5/e- 1!IIIIIIIIIITIIIIIIIIII:Iu!5IIIIII!I I IIIIIIIIIIii'CIIIIIIIIII;I'Illlllllllif I � I!FIIIIIIII''I IIIIIIIIIIIIWIIAll IIIIIi!!IIII''LIIIIIIIIIIIIII!!iilllll ? ,,'°a}.. w enenuRE OGAS Zo 11-3/4• 1 29/32 to 1.Installation space Note:Leave both sides ..— free of obstruction. m More than 3-15/16' Y I dua *ril e. ifs; p /� E• I l I It— N. More than 19.11/16"n .: Lone nut Connector Note:Leave overhead s i �_'' free of obstruction. - More than 3-15116• 6 More than13-25132' More than 19-11/16' 2.Service space to �s More than 3-15/16' MOIIIM SERVICE SPACE More than 13-25/32" More than 13-25/32" ,,,f„ f - MITSUBISHI ELECTRIC 1 CERTIFIED., ""'` � HVAC Advanced Products Division urrt.nv s",ml nrnel s :It, «. o 3400 Lawrenceville Suwanee Rd nla�a o az m,z10 Suwanee,GA 30024 .,, ..,. -,. .. �fSTb� ® Tele 6783762900•Fac8068899204 Toll Free:800-433-4822(#3) www.mehvac.com C SD-MXZ-2B2ONA-1 for Multiple Indoor Unit Styles-201005 ©MITSUBISHI ELECTRIC/HVAC 2010 SpedAcalions westEject to chalpe without notice