Loading...
Report D_ EL 14795 S.W. 72nd Avenue PORTLAND, OR 97224 PHONE 503-620-4020 FIRE INC. CCB# 64674-1058 p VFD • B U R N H A M & AS H ate NG DIVISION APARTMENTS - BLDG. 2 TIGARD, OR City of Tigard A. rov-d Plans fByri Date \ 12e1-€1 v2 OFFICE COPY DATA SUBMITTAL FOR FIRE PROTECTION SYSTEM BA-ACCO SUBMITTAL REVIEW teviewed for general compliance with contract ��IIIII�'II III NO EXCEPTIONS NOTED ❑ DISAPPROVED ocuments. ❑ NO EXCEPTIONS NOTED IN CORRECTED COPY JBA-ACCO X Reviewed ❑ REVISE AND RESUBMIT ❑ NOT REVIEWED Reviewed: Make Corrections Noted The delegated design work referenced in this submittal is the Reviewed: Revise & Resubmit responsibility of the design-build contractor. The design-build contractor is fully responsible for the detailed design and :ontractor's review does not relieve subcontractor/supplier of construction and its coordination with the Work in accordance with is responsibility for dimensions,quantities, accuracy, the Contract Documents and all applicable rules, regulations and oordination w/other trades or completeness of this other requirements. Review by Architect is solely for aesthetic ubmittal. Subcontractor/Supplier remains responsible for the intent and general compliance with the design intent in the >rms&conditions of his contract/purchase order with BA-ACCO, LLC. Contract Documents. Such review does not, in any way, relieve ate 3-15-2016 By Brian Lasswell the delegated design contractor from strict compliance with all Contract Requirements and the Authority Having Jurisdiction. BA-ACCO Job# J 15-001 Submittal# 21-0000 6 Digitally signed by Jos Cabot Josh Cabot evewedlthsdeocument SERA Date:2016.03.22 10:21:44-07'00' FEBRUARY 10, 2016 DELTA FIRE, INC. PROJECT #15-5481 FIRE PROTECTION CONTRACTORS Burnham&Ash Apartments—Bldg. 1 Tigard, OR February 10, 2016 Page 2 of 3 TABLE OF CONTENTS Pipe & Fittings Steel Pipe CPVC Pipe Ductile Iron Pipe Class 52 CPVC Fittings Ductile Iron Screwed Fittings Mechanical Joint Fittings Victaulic Grooved Fittings Style #01, 02, 03 & 06 Victaulic Coupling Style #09 Victaulic Coupling Style #75 Hangers Anvil Ring Hanger Fig. #69 Anvil Threaded Rod Anvil Pipe Clamp Fig. #212 Anvil Strut Clamp Anvil Strut Channel Hex Lag Screw Tolco `Stand Off' Hanger & Retrainer CPVC Fig. #28 Tolco Double Fastener Strap Horizontal CPVC Fig. #23 Tolco Double Fastener Strap Vertical CPVC Fig. #24 Tolco `In-line' Sway Brace Fig. #4L Tolco Universal Swivel Sway Brace Fig #980 Tolco 'Fast Clamp' Sway Brace Attachment Fig #1000 Tolco Sway Brace Attachment Fig. #1001 Sammy GST 20 Vertical Screw Sammy SWG 20 Horizontal Screw Sprinkler Heads Reliable Model F1 FR-56 - 1/2", 155 Degree, White, Pendent Reliable Model F1 FR-56 - 1/2", 155 Degree, Chrome, HSW Reliable Model F1FR-56 - 1/2", 200 Degree, Brass, Upright Reliable Model F1 RES-49 - 1/2", 155 Degree, Recessed, White, Pendent Reliable Model F3QR - 1", 155 Degree, Chrome, Dry Pendent Reliable Model F3QR - 1", 155 Degree, Chrome, Dry HSW Reliable Model G5-56 - 1/2", 155 Degree, White, Concealed Reliable Model J112 —3/4", 155 Degree, Brass Upright Tyco Model SW20 - 2/4", 155 Degree, Brass, HSW FIRE PROTECTION CONTRACTORS Burnham&Ash Apartments—Bldg. 1 Tigard. OR February 10,2016 Page 3 of 3 Sprinkler Valves Potter Roemer Hose Valve Fig. #4065 Potter Roemer Cap/Chain Fig. #4612-4625 Potter Roemer FDC — Straight Fig. #5710 Reliable Model D Dry Pipe Valve Victaulic Butterfly Valve #705 Victaulic Check Valve #717 Watts Pressure Relief Valve Switches & Bells Potter PS-10 Pressure Switch Potter PS-40 Tamper Switch Potter VSR-F Flow Switch Potter 6" Alarm Bell Backflow Device Ames Colt C300 DDCVA Miscellaneous Jenny Air Compressor Hilti FS1 Fire Stopping FIRE PROTECTION CONTRACTORS 5 A DELT PORT S.W. 72R 9722ue PORTLAND, OR 97224 PHONE 503-620-4.020 iiAE,iE C■ CCB# 64174 PIPE & FITTINGS FIRE PROTECTION CONTRACTORS I 111. I Man r a. MINI Al a i. r t aNI /NIJ t' NVCN -=Pipe and Supply Corp. Pipe Specification A135 Specification A135 NPS 1/4 -- 30", Schedules 10, 40 and XL THD, Lightwall Scope Covers two grades of electric resistance welded steel pipe. Grade A is adapted for flanging and bending and is suitable for welding. Purpose for which pipe is intended should be stated on order. Kinds of Steel Permitted Open-hearth Basic-oxygen For Pipe Material Electric-furnace Permissible Variations The minimum wall thickness at any point shall not be more than 12.5%under the nominal wall thickness specified. in Wall Thickness Threadable,lightwall(XL)must meet manufacturers minimums. Chemical C max% Mn max% P max% S max% Requirements Seamless or ERW Grade A 0.25 0.95 0.05 0.06 Grade B 0.30 1.20 0.05 0.06 Tensile Grade A Grade B Requirements Tensile Strength,min.,psi 48,000 60,000 Yield Strength,min.,psi 30,000 35,000 NDE& Hydrostatic inspection test pressures for plain end and threaded are specified. Hydrostatic pressure shall be maintained Hydrostatic for not less than 5 seconds for all sizes of electric resistance weld pipe. Non-destructive electric test should be in accordance Testing with practices E213,method E227 or practice E213. Permissible Variations Plus or Minus 10%schedule 10 in Weights per Foot Plus 10%minus 3 1/2%schedule 40 Permissible Variations Plus or minus 1% in Outside Diameter Mechanical Tests Tensile Test--Transverse retumed on pipe NPS 8 and larger. Specified Flattening test--Three steps required with weld located 0°or 90°from the line of direction of force required. Number of Flattening and tensile on one length of pipe from each lot of 400 lengths or less of a style. Tests Required Lengths Pipe shall be furnished in 38'with a minimum of 20 ft. Pipe furnished to schedule 10 shall be in a specified length between 16 and 22 ft. Required Markings Rolled,Stamped or Stenciled(Mfgrs.Option) on Each Length Name or brand of manufacturer. (On Tags attached to Kind of pipe,that is,electric-resistance welded A,electric welded B,same schedule wall thickness,schedule 10 or 40,NL each Bundle in case ASTM A135 of Bundled Pipe) Length of pipe. General End finish may be plain end beveled or plain end square cut. Information SPEARS FlameGuard®CPVC Fire Sprinkler Products Technical Information FlameGuardO Product Weights & Dimensions The information contained in this section is based on current information and Product design at the time of publication and is subject to change without notification.Our ongoing commitment to product improvement may result in some variation.No representations,guarantees or warranties of any kind are made as to its accuracy,suitability for particular applications or results to be obtained therefrom.For verification of technical data or additional information not contained herein,please contact Spears®Technical Services Department[West Coast:(818)364-1611—East Coast:(678)985-1263]. • General Information RECOMMENDATIONS FOR INSTALLERS AND USERS: Plastic piping systems should be ENGINEERED, INSTALLED and OPERATED in accordance with ESTABLISHED DESIGN AND ENGINEERING STANDARDS AND PROCEDURES for plastic piping systems.Suitability for the intended service application should be determined by the installer and/ or user prior to installation of a plastic piping system.All Installation and maintenance personnel should be trained in the proper handling and installation requirements and precautions of plastic piping systems. PRIOR TO ASSEMBLY,all piping system components should be inspected for damage or irregularities.Mating components should be checked to assure that tolerances and engagements are compatible.Do not use any components that appear irregular or do not fit properly.Contact the appropriate manufacturer of the component product in question to determine usability. Consult all applicable codes and regulations for compliance prior to installation. Installation must be made in accordance with Spears®Manufacturing Company FlameGuard®CPVC Fire Sprinkler Piping Products Installation Instructions-FG-3 NOTE—Individual or group instruction in correct solvent welding procedures is available by contacting your local distributor or your servicing Spears® Regional Distribution Center. SOLVENT CEMENT CONNECTIONS—Spears®Manufacturing Company recommends the use of Spears®FS-5 One Step solvent cement for joining Spears® products.Use of solvent cementing products not approved for CPVC fire sprinkler systems,or failure to follow installation instructions will automatically void the warranty. THREADED CONNECTION—Spears®Manufacturing Company recommends the use of Spears®BLUE 75TM Thread Sealant.This product has been tested by Spears®and the sealant manufacturer for compatibility wittrthe Spears®CPVC fire sprinkler products.Consult the sprinkler head manufacturer before using this product.WARNING:OTHER PIPE JOINT COMPOUNDS OR PASTES MAY CONTAIN SUBSTANCES THAT COULD CAUSE STRESS CRACKING IN THE CPVC OR OTHER FITTING COMPONENTS.Care must be taken to avoid over torquing-generally 1 to 2 turns beyond finger tight is all that is required to make up a threaded connection.Factory testing has indicated 10-25 ft.lbs.of torque is adequate to obtain a leak free seal. GASKET SEALED THREAD CONNECTIONS—This type of connection can only be made with Spears®TorqueSafeT° style Gasket Sealed Female Sprinkler Adapters. DO NOT USE ANY TYPE OF THREAD SEALANT WHEN INSTALLING THIS TYPE OF ADAPTER.Tape or paste may impair proper sealing and function.Testing has shown that hand tight until snug is all that is needed to seal this special connection. Installation Training Available-Contact Spears®Technical Services for Details FlameGuard®Products must be installed in accordance with Spears®CPVC Fire Sprinkler Piping Products Installation Instructions,National Fire Protection Association Standards 13, 13R,13D,and in accordance with local codes.Code requirements and field conditions may differ. It is the responsibility of the installing contractor to insure that the product is suitable to meet these requirements. Dimension Reference G = (LAYING LENGTH)Intersection of center lines to bottom of socket/thread;90° M = Outside diameter of socket/thread hub;±1/16 inch. elbows,tees,crosses;±1/32 inch. N = Socket bottom to socket bottom;couplings;±1/16 inch. H = Intersection of center lines to face of fitting;90°elbows tees,crosses;±1/32 inch. Q = Width of flats;±1/16 inch. J = Intersection of center lines to bottom of socket/thread;45°elbows;±1/32 inch W= Height of cap;±1/16 inch. L = Overall length of fittings;±1/16 inch. CPVC FIRE SPRINKLER PIPE SDR 13.5(ASTM F 442) Nominal Size Average O.D. Average I.D. Part Number Approx.Weight Lbs./Ft. Inches (mm) Inches (mm) Inches (mm) CP-007 3/4 (19.1) 1.050 (26.7) .874 (22.5) 0.168 CP-010 1 (25.4) 1.315 (33.4) 1.101 (28.2) 0.262 CP-012 1-1/4 (31.8) 1.660 (42.2) 1.394 (35.6) 0.418 CP-015 1-1/2 (38.1) 1.900 (48.3) 1.598 (40.7) 0.548 CP-020 2 (50.8) 2.375 (60.3) 2.003 (50.9) 0.859 CP-025 2-1/2 (63.5) 2.875 (73.0) 2.423 (61.5) 1.257 CP-030 3 (76.2) 3.500 (88.9) 2,950 (75.0) 1.867 "Lead Free"low lead certification–unless other wise specified,all Spears®FlameGuard®fittings specified here-in are certified by NSF International to ANSI/ NSF®Standard 61,Annex G and is in compliance with California's Health&Safety Code Section 116825(commonly known as AB1953)and Vermont Act 193. Weighted average lead content<=0.25%.Spears®PVC and CPVC Pipe,Fittings and Valves have always been lead-free and Certified by NSF International for use in potable water systems.Spears®offers a wide range of lead-free specialty fittings and transition adapters for plumbing applications.However,certain brass threaded adapter fittings for applications that are not intended to convey water for human consumption through drinking or cooking are still produced and available. PaSuitable for Oil-Free air handling to 25 psi,not for distribution of compressed air or gas Spears®Manufacturing Companyge Due to Material Cost Variations,Prices Subject to Change.Check On-line Catalog @ www.spearsmfg.com FlameGuard®CPVC Fire Sprinkler Products Technical Information FlameGuard® Product Weights & Dimensions 1 DE • _ 1 SOCKET DIMENSIONS [...-c-.-1 SCH 40-ASTM F438 litiiiiitAIIIIIR-- SCH 80-ASTM F439 t III A 1111101112 4 Size Socket Socket Tolerance SCH 40 Minimum SCH 80 Minimum Entrance A Bottom B Socket Length C Socket Length C 3/4 1.058 1.046 ±.004 .719 1.000 1 1.325 1.130 ±.005 .875 1.125 1-1/4 1.670 1.655 ±.005 .938 1.250 1-1/2 1.912 1.894 ±.006 1.094 1.375 2 2.387 2.369 ±.005 1.156 1.500 2-1/2 2.889 2.868 ±.007 1.750 1.750 3 3.516 3.492 ±.008 1.875 1.875 TEE - Socket x Socket x Socket t! i M Mill - - G �--- HI S L Part Number Size G H L M Approx.Wt.(Lbs.) 4201-007 3/4 9/16 1-1/2 2-31/32 1-5/16 .11 4201-010 1 7/8 1-13/16 3-5/8 1-5/8 .20 4201-012 1-1/4 15/32 2-3/32 4-7/32 2 .29 4201-015 1-1/2 1-5/32 2-9/16 5-3/32 2-11/32 .54 4201-020 2 1-13/32 2-15/16 5-7/8 2-7/8 .86 4201-025 2-1/2 1-23/32 3-1/2 7 3-15/32 1.62 4201-030 3 2-1/16 3-31/32 7-15/16 4-5/32 2.53 REDUCING TEE h-tM1 Socket x Socket x Socket p3f t= H1 M 2 Mififir-*A2 ; G W.G2 H f � H2- L Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx.Wt. (Lbs.) 4201-102 3/4x3/4x1 3/4 3/4 3/4 1-11/16 1-25/32 1-11/16 3-13/32 1-5/16 1-21/32 1-5/16 .13 4201-125 1x3/4x3/4 23/32 7/8 23/32 1-25/32 1-13/16 1-21/32 3-7/16 1-19/32 1-11/32 1-5/16 .16 4201-126 1x3/4x1 23/32 23/32 3/4 1-27/32 1-27/32 1-3/4 3-19/32 1-5/8 1-5/8 1-5/16 .17 4201-131 1x1x3/4 11/16 13/16 11/16 1-13/16 1-13/16 1-13/16 3-5/8 1-5/8 1-5/16 1-5/8 .17 4201-157 1-1/4x1x3/4 11/16 1-1/32 11/16 1-15/16 2-1/32 1-13/16 3-25/32 2-3/32 1-13/32 1-23/32 .32 Made in the U.S.A. Suitable for Oil-Free air handling to 25 psi.not for distribution of compressed air or gas Page 386 Due to Material Cost Variations,Prices Subject to Change.Check On-line Catalog @ www.spearsmfg.com g FlameGuard®CPVC Fire Sprinkler Products Technical Information SPAS FlameGuard® Product Weights & Dimensions r REDUCING TEE (continued) f 1 M1 Socket x Socket x Socket }___PL..._{ t M2 { H1 i A G1 G MUM G2 H -.—H2 L I Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx.Wt. (Lbs.) 4201-158 1-1/4x1x1 27/32 29/32 25/32 2-1/16 2-1/32 1-29/32 3-15/16 1-31/32 1-5/8 1-5/8 .24 4201-159 1-1/4x1x1-1/4 31/32 31/32 31/32 2-7/32 2-7/32 2-3/32 4-11/32 2-1/8 2-1/8 1-23/32 .36 4201-167 1-1/4x1-1/4x3/4 21/32 1 21/32 1-29/32 2 1-29/32 3-13/16 2 1-5/16 2 .22 4201-168 1-1/4x1-1/4x1 13/16 1 13/16 2-1/16 2-1/8 2-1/16 4-1/8 1-31/32 1-21/32 1-31/32 .24 4201-169 1-1/4x1-1/4x1-1/2 1-1/8 15/16 1-1/8 2-3/8 2-11/32 2-3/8 4-3/4 2-3/32 2-11/32 2-3/32 .51 4201-201 1-1/2x1-1/4x3/4 11/16 1 1/4 2-1/16 2 1-15/16 4 2-5/16 1-3/8 2-1/16 .41 4201-202 1-1/2x1-1/4x1 27/32 1-1/32 1 2-7/32 2-5/32 2-1/4 4-15/32 2-5/16 1-11/16 2-1/16 .42 4201-210 1-1/2x1-1/2x3/4 11/16 1-1/32 11/16 2-1/16 2-1/32 2-1/16 4-5/32 2-11/32 1-13/32 2-11/32 .39 4201-211 1-1/2x1-1/2x1 13/16 1-3/32 13/16 2-3/16 2-1/4 2-3/16 4-3/8 2-11/32 1-3/4 2-11/32 .41 4201-212 1-1/2x1-1/2x1-1/4 1-1/32 1-3/32 1-1/32 2-13/32 2-11/32 2-13/32 4-13/16 2-11/32 2-1/8 2-11/32 .49 4201-213 1-1/2x1-1/2x2 1-9/32 1-5/32 1-9/32 2-21/32 2-21/32 2-21/32 5-11/32 2-11/32 2-29/32 2-11/32 .64 4201-248 2x2x3/4 11/16 1-13/32 11/16 2-7/32 2-7/16 2-7/32 4-7/16 2-27/32 1-3/8 2-27/32 .52 4201-249 2x2x1 27/32 1-13/32 27/32 2-11/32 2-9/16 2-11/32 4-23/32 2-7/8 1-3/4 2-7/8 .58 ' 4201-250 2x2x1-1/4 1-1/32 1-11/32 1-1/32 2-17/32 2-19/32 2-17/32 5-3/32 2-7/8 2-3/32 2-7/8 .65 4201-251 2x2x1-1/2 1-5/32 1-7/16 1-5/32 2-11/16 2-13/32 2-11/16 5-3/8 2-7/8 2-13/32 2-7/8 .79 4201-289 2-1/2x2-1/2x1 27/32 1-23/32 27/32 2-5/8 2-27/32 2-5/8 5-1/4 3-17/32 1-23/32 3-17/32 1.01 4201-290 2-1/2x2-1/2x1-1/4 1-3/32 1-23/32 1-1/32 2-13/16 2-31/32 2-13/16 5-21/32 3-9/16 2-3/32 3-9/16, '9.13 4201-291 2-1/2x2-1/2x1-1/2 1-3/16 1/2 1-3/16 2-15/16 1-7/8 2-15/16 5-7/8 3-15/32 2-11/32 3-15/32 1.26 4201-292 2-1/2x2-1/2x2 1-13/31 1-5/8 1-13/32 3-3/16 3-1/8 3-3/16 6-3/8 3-1/2 2-7/8 3-1/2 1.37 4201-335 3x3x1 7/8 1-15/16 7/8 2-3/4 3-1/16 2-3/4 5-15/32 4-3/16 1-23/32 4-3/16 1.26 4201-336* 3x3x1-1/4 1-3/8 1-3/4 1-3/8 3-5/16 3-1/2 3-5/16 6-5/8 4-1/8 2-7/8 4-1/8 1.94 4201-337 3x3x1-1/2 1-5/32 2-1/16 1-5/32 3-1/32 3-7/16 3-1/32 6-3/32 4-3/16 2-3/8 4-3/16 1.46 4201-338 3x3x2 1-7/16 1-13/16 1-7/16 3-5/16 3-5/16 3-5/16 6-19/32 4-3/16 2-7/8 4-3/16 1.69 4201-339 3x3x2-1/2 1-3/4 1-31/32 1-3/4 3-5/8 3-23/32 3-5/8 7-1/4 4-3/16 3-17/32 4-3/16 2.11 *Branch Outlet Sized with Bushing TorqueSafeTM SPRINKLER HEAD TEE Gasket Sealed Brass Ml Thread Insert Style ___. R 1 G1—I f Socket x Socket x Gasket Fipt t f i1 With Elastomer Seal-Use NO Thread Sealant M M2 G """' G2 H H2 L Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx.Wt.(Lbs.) 4202-101 G 3/4x3/4x1/2 7/16 1-3/16 7/16 1-7/16 1-7/16 1-17/32 2-29/32 1-3/8 1-3/8 1-3/8 .22 4202-124 G 1x3/4x1/2 7/16 1-11/32 9/16 1-9/16 1-11/16 1-9/16 3-1/8 1-11/16 1-3/8 1-3/8 .26 4202-130 G 1x1x1/2 7/16 1-11/32 7/16 1-9/16 1-11/16 1-9/16 3-1/8 1-23/32 1-3/8 1-23/32 .28 4202-166 G 1-1/4x1-1/4x1/2 7/16 1-5/8 7/16 1-11/16 1-15/16 1-11/16 3-3/8 2-1/16 1-3/8 2-1/16 .34 4202-209 G 1-1/2x1-1/2x1/2 1/2 1-13/16 1/2 1-7/8 2-3/32 1-7/8 3-3/4 2-11/32 1-3/8 2-11/32 .41 4202-247 G 2x2x1/2 1/2 2-1/16 1/2 2 2-11/32 2 4-1/32 2-27/32 1-3/8 2-27/32 .54 Not intended to convey or dispense water for human consumption through drinking or cooking PaSuitable for Oil-Free air handling to 25 psi,not for distribution of compressed air or gas Spears®Manufacturing Companyge Due to Material Cost Variations,Prices Subject to Change.Check On-line Catalog @ www.spearsmfg.com FlameGuard®CPVC Fire Sprinkler Products Technical Information FlameGuard® Product Weights & Dimensions uSihA SPRINKLER HEAD TEE Brass Thread Insert Style (: .il G1— t Socket x Socket x Fipt A H1 M M2 G2 H L H2 L Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx.Wt.(Lbs.) 4202-010 1x1x1 21/31 1-1/8 21/31 1-25/32 1-29/32 1-25/32 3-19/32 1-23/32 1-23/32 1-23/32 .37 Not intended to convey or dispense water for human consumption through drinking or cooking SofTorqueTM SR REDUCING TEE Gasket Sealed Special Reinforced Plastic Thread Style Socket x Socket x SR Fipt M1 With Elastomer Seal-Use NO Thread Sealant i1 G1H1 G <>- G2 H >4 H2—e- L > Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx.Wt. 4202-101GSR 3/4x3/4x1/2 7/16 1-1/2 7/16 1-3/8 1-7/8 1-3/8 2-3/4 1-5/16 1-3/8 1-5/16 .16 4202-130GSR 1x1x1/2 7/16 1-5/8 7/16 1-1/2 2 1-1/2 3 1-5/8 1-3/8 1-5/8 .20 SPRINKLER REDUCING HEAD TEE J Brass Thread Insert Style 11 Socket x Socket x Fipt r M M2 G1 I �wraw 414444 L Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx.Wt.(Lbs.) 4202-101 3/4x3/4x1/2 7/16 1-1/16 7/16 1-15/32 1-5/8 1-15/32 2-29/32 1-13/32 1-3/16 1-13/32 .20 4202-124 1x3/4x1/2 7/16 1-11/32 9/16 1-9/16 1-11/16 1-9/16 3-1/8 1-11/16 1-3/8 1-3/8 .26 4202-130 1x1x1/2 7/16 1-7/32 7/16 1-9/16 1-25/32 1-9/16 3-1/8 1-3/4 1-3/16 1-3/4 .26 4202-156 1-1/4x1x1/2 7/16 1-7/16 9/16 1-11/16 2-1/32 1-11/16 3-3/8 2-3/32 1-3/16 1-23/32 .30 4202-166 1-1/4x1-1/4x1/2 7/16 1-15/32 7/16 1-11/16 2-1/32 1-11/16 3-3/8 2-3/32 1-3/16 2-3/32 .31 4202-199 1-1/2x1-1/4x1/2 1/2 1-5/8 9/16 1-7/8 2-3/16 1-13/16 3-11/16 2-11/32 1-3/16 2-1/16 .37 4202-209 1-1/2x1-1/2x1/2 1/2 1-5/8 1/2 1-7/8 2-3/16 1-7/8 3-3/4 2-11/32 1-3/16 2-11/32 .38 4202-237 2x1-1/2x1/2 1/2 1-27/32 17/32 2 2-7/16 1-29/32 3-15/16 2-7/8 1-3/16 2-11/32 .47 4202-247 2x2x1/2 1/2 1-7/8 1/2 2 2-7/16 2 4-1/32 2-27/32 1-3/16 2-27/32 .50 Not intended to convey or dispense water for human consumption through drinking or cooking Made in the U.S.A. Suitable for Oil-Free air handling to 25 psi,not for distribution of compressed air or gas Page 388 Due to Material Cost Variations,Prices Subject to Change.Check On-line Catalog @ www.spearsmfg.com g FlameGuard®CPVC Fire Sprinkler Products Technical Information I- , PEARS FlameGuard® Product Weights & Dimensions SPRINKLER HEAD TEE rM1~1 Special Reinforced i It5 G1 t1 Plastic Thread Style F `� j Socket x Socket x SR Fipt M M2 -- G G2 H H2 Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx.Wt.(Lbs.) 4202-010SR 1x1x1 21132 314 21132 1-25/32 1-5/8 1-25/32 3-19/32 1-23/32 1-11/16 1-23/32 .26 SPRINKLER REDUCING HEAD TEE H-mi-H Special Reinforced --rf I Plastic Thread Style mR G, ' Socket x Socket x SR Fipt G G2,1 H -*-H2-.- - L Part Number Size G 01 G2 H H1 H2 L M M1 M2 Approx.Wt.(Lbs.) 4202-101SR 3/4x3/4x1/2 19/32 25/32 19/32 1-19/32 1-7/16 1-19/32 3-7/32 1-13/32 1-3/16 1-13/32 .15 4202-124SR 1x3/4x1/2 7/16 29/32 9/16 1-19/32 1-5/8 1-9/16 3-5/32 1-23/32 1-3/16 1-17/32 .19 4202-130SR 1x1x112 7/16 29132 7116 1-9/16 1-5/8 1-9/16 3-1/8 1-23/32 1-3/16 1-23/32 .20 4202-156SR 1-1/4x1x1/2 15/32 1-5/32 19/32 1-23132 1-7/8 1-23/32 3-13/32 2-3/32 1-3/16 1-23132 .26 4202-166SR 1-1/4x1-1/4x1/2 7/16 1-1/8 7/16 1-11/16 1-27/32 1-11/16 3-3/8 2-3/32 1-3/16 2-3/32 .26 4202-168SR 1-1/4x1-1/4x1 27/32 1-1/32 27/32 2-3/32 1-29/32 2-3/32 4-7/32 2-3/32 1-11/16 2-3/32 .34 4202-199SR 1-1/2x1.1/4x1/2 9/16 1-9/32 17/32 1-15/16 2 1-25/32 3-23/32 2-11/32 1-3/16 2-3/32 .33 _ 4202-209SR 1-1/2x1-1/2x112 112 1-1/4 1/2 1-7/8 1-31/32 1.718 3-3/4 2-11/32 1-3/16 2-11132 .35 4202-211SR 1-1/2x1-1/2x1 27/32 1-7/32 27/32 2-7/32 2-1/8 2-7/32 4-15/32 2-11/32 1-23/32 2-11/32 .44 4202-237SR 2x1-1/2x1/2 23/32 1-9/16 3/8 2-7/32 2-9/32 1-3/4 3-31/32 2-7/8 1-3/16 2-11/32 .45 4202-247SR 2x2x1/2 1/2 31/32 1/2 2 1-11/16 19/32 4 2-7/8 1-3/16 2-7/8 .48 4202-287SR 2-112x2-1/2x112 17/32 1-314 17/32 2-9/32 2-1/2 2-9/32 4-19/32 3-1/2 1-7/32 3-1/2 .78 TorqueSafeTM M1 SPRINKLER HEAD TEE t--- ilk G1 Gasket Sealed i H1 - T 1 Brass Thread Insert Style M !' M2 1 jm Socket x Gasket Fipt x Socket .1 With Elastomer Seal-Use NO Thread Sealant �� G2 1.-*--G H �---H2 L Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx.Wt.(Lbs.) 4203-122 G 1x1/2x1 19/32 13/16 1-13/32 1-19/32 1-27/32 1-3/4 3-11/32 1-5/8 1-5/8 1-3/8 .25 Not intended to convey or dispense water for human consumption through drinking or cooking Pa 25 ring Company Page Due to Material Cost Variations,Prices Subject to Change.Check On-line Catalog @ www.spearsmfg.com FlameGuard®CPVC Fire Sprinkler Products Technical Information FlameGuard® Product Weights & Dimensions • SPEIit SPRINKLER HEAD TEE -- Brass Thread Insert Style 0G1 Socket x Fipt x Socket t 11 � ,ri2k7ir G G2 H -- H2 Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx.Wt.(Lbs.) 4203-122 1x1/2x1 23/32 3/4 1-1/4 1-5/8 1-5/8 1-15/16 3-1/2 1-23/32 1-23/32 1-3/16 .25 Not intended to convey or dispense water for human consumption through drinking or cooking SPRINKLER HEAD TEE M1—I Special Reinforced _ PrI G1- Plastic Thread Style fii1 M2 Li Socket x SR Fipt x Socket Itill� _I G2 H H2— L Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx.Wt.(Lbs.) 4203-122SR 1x1/2x1 27/32 23/32 1-3/32 1-23/32 1-5/8 1-25/32 3-13/32 1-3/4 1-3/4 1-3/16 .21 STREET TEE Spigot x Socket x Socket PIPE M2 o H1 IG1 G2 - -H —i--H2— - L ---,- Part sPart Number Size G G1 G2 H H1 H2 L M1 M2 Approx.Wt.(Lbs.) 4244-007 3/4 13/16 27/32 27/32 1-13/16 1-7/8 1-7/8 3-5/8 1-13/32 1-13/32 .16 4244-010 1 1-5/32 1-1/32 1-1/32 2-1/8 1-29/32 1-29/32 4-3/16 1-3/4 1-3/4 .27 4244-012 1-1/4 1-1/4 1 1 2-7/16 2-9/32 2-9/32 4-27/32 2-3/32 2-3/32 .42 4244-015 1-1/2 1-13/16 1-1/8 1-1/8 2-7/8 2-9/16 2-9/16 5-11/32 2-11/32 2-11/32 .56 4244-020 2 1-23/32 1-7/16 1-13/32 3-1/4 2-15/16 2-15/16 6-5/32 2-7/8 2-7/8 .84 Made in the U.S.A. Suitable for Oil-Free air handling to 25 psi,not for distribution of compressed air or gas Page 390 Due to Material Cost Variations,Prices Subject to Change.Check On-line Catalog @ www.spearsmfg.com g N FlameGuard®CPVC Fire Sprinkler Products Technical Information SPEARS FlameGuard® Product Weights & Dimensions J 90° ELBOW Socket x Socket G Fra il H, min ,. .a Part Number Size G h M Approx.Wt.(Lbs.) 4206-007 3/4 9/16 1-1/2 1-5/16 .07 4206-010 1 3/4 1-5/8 1-5/8 .11 4206-012 1-1/4 15/16 2-3/16 2 .22 4206-015 1-1/2 1-5/32 2-17/32 2-3/8 .41 4206-020 2 1-13/32 2-29/32 2-7/8 .62 4206-025 2-1/2 1-15/32 3-3/8 3-1/2 1.15 4206-030 3 1-29/32 3-13/16 4-7/32 1.83 SIDE OUTLET ELBOW Socket x Socket x Socket llPIM ('-----7< 1 I G H—.I Part Number Size G H M Approx.Wt.(Lbs.) 4213-007 3/4 27/32 1-19/32 1-5/16 .09 4213-010 1 13/16 1-7/8 1-5/8 .18 REDUCING 90° ELBOW Socket x Socket 4 H1 G1 - -1 M1 JPi TI. . lam—M—+I Part Number Size G G1 H H1 M M1 Approx.Wt.(Lbs.) 4206-131 1x3/4 21/32 13/16 1-25/32 1-13/16 1-19/32 1-5/16 .11 Page SuitableDue to Material Cost Variations,Prices Subject to Change.Check On-line Catalog @ www.spearsmfg.com FlameGuard®CPVC Fire Sprinkler Products Technical Information FlameGuard® Product Weights & Dimensions SPEARS • TorqueSafe' 90° SPRINKLER HEAD ELBOW Gasket Sealed Brass Thread Insert Style Socket x Gasket Fipt With Elastomer Seal-Use NO Thread Sealant H1 G1 G "IIt fjpir 1 II Part Number Size G G1 H H1 M M1 Approx.Wt.(Lbs.) 4207-101 G 3/4x1/2 9/16 1-7/32 1-13/32 1-17/32 1-13/32 1-3/8 .19 4207-130 G 1x1/2 7/16 1-3/16 1-9/16 1-11/16 1-23/32 1-3/8 .23 4207-166 G 1-1/4x1/2 15/32 1-19/32 1-15/16 1-11/16 2-3/32 1-3/8 .25 Not intended to convey or dispense water for human consumption through drinking or cooking SPRINKLER HEAD 90° ELBOW Brass Thread Insert Style Socket x Fipt H1 G1 G gp 'III,11„�jj�l lial M1 1 I~ M _.i Part Number Size G G1 H H1 M M1 Approx.Wt.(Lbs.) 4207-101 3/4x1/2 1/2 1-3/32 1-1/2 1-5/8 1-13/32 1-3/16 .17 4207-130 1x1/2 7/16 1-7/32 1-19/32 1-25/32 1-23/32 1-3/16 .21 4207-131 1x3/4 17/32 1-11/32 1-21/32 1-31/32 1-23/32 1-3/8 .25 4207-166 1-1/4x1/2 15/32 1-17/32 1-11/16 1-15/16 2-3/32 1-17/32 .33 Not intended to convey or dispense water for human consumption through drinking or cooking SofTorqueTM SR 90° ELBOW SPRINKLER HEAD ADAPTER Gasket Sealed Special Reinforced Plastic Thread Style Socket x SR Fipt With Elastomer Seal-Use NO Thread Sealant k "' G,-1 G .4-1- 1 ,: . H ._-.� :LtidI M .I Part Number Size G G1 H H1 M M1 Approx.Wt.(Lbs.) 4207-101GSR 3/4x1/2 7/16 1-17/32 1-3/8 1-27/32 1-11/32 1-3/8 .17 4207-130GSR 1x1/2 7/16 1-11/16 1-1/2 2 1-21/32 1-3/8 .19 4207-166GSR 1-1/4x1/2 7/16 1-7/8 1-11/16 2-7/32 2 1-3/8 .22 Made in the U.S.A. Suitable for Oil-Free air handling to 25 psi,not for distribution of compressed air or gas Page 392 Due to Material Cost Variations,Prices Subject to Change.Check On-line Catalog @ www.spearsmfg.com g FlameGuard®CPVC Fire Sprinkler Products Technical Information SPEARS FlameGuard® Product Weights & Dimensions g seons SPRINKLER HEAD 90° ELBOW Special Reinforced Plastic Thread Style H1 -7 Socket x SR Fipt G1 ,. I '-!!!1!1111 i H III I-4—M—,I Part Number Size G G1 H . H1 M M1 Approx.Wt.(Lbs.) 4207-101SR 3/4x1/2 11/32 13/16 1-15/32 1-1/2 1-13/32 1-3/16 .14 4207-130SR 1x1/2 7/16 7/8 1-9/16 1-5/8 1-23/32 1-3/8 .20 4207-131SR 1x3/4 1/2 7/8 1-5/8 1-9/16 1-23/32 1-3/8 .16 4207-166SR 1-1/4x1/2 13/32 1-1/32 1-21/32 1-23/32 2-3/32 1-7/32 .19 90° STREET ELBOW -.4—H1----.{ Spigot x Socket G1 A M1 I - - H , 1 I r I PIPE O.D. Part Number Size G G1 H H1 M1 Approx.Wt.(Lbs.) 4209-007 3/4 29/32 19/32 1-15/16 1-11/16 1-13/32 .12 4209-010 1 1-3/32 27/32 2-7/32 1-7/32 1-23/4 .20 4209-012 1-1/4 1-9/16 27/32 2-13/16 2-3/32 2-3/32 .32 4209-015 1-1/2 1-15/32 1-3/16 2-27/32 2-9/16 2-11/32 .42 4209-020 2 1-23/32 1-3/8 3-7/32 2-15/16 2-27/32 .65 22-1/2° ELBOW Socket x Socket J /41141/1 1111611111 i I_._MSI Part Number Size H J M Approx.Wt.(Lbs.) 4216-007 3/4 1-3/16 7/32 1-13/32 .09 4216-010 1 1-3/8 9/32 1-25/32 .14 4216-012 1-1/4 1-1/2 5/16 2-3/32 .20 4216-015 1-1/2 1-7/16 13/32 1-3/8 .19 4216-020 2 1-7/8 3/8 2-27/32 .43 4216-025 2-1/2 2-7/32 15/32 3-1/2 .72 4216-030 3 2-3/8 1/2 4-5/32 1.00 Pa g Due to Material Cost Variations,Prices Subject to Change.Check On-line Catalog @ www.spearsmfg.com I FlameGuard®CPVC Fire Sprinkler Products Technical Information FlameGuard® Product Weights & Dimensions 22-1/2° STREET ELBOW Spigot x Socket H1 3 /''' M1 1 itifry r- f t1H J [- -I PIPE O.D. Part Number Size H H1 J J1 M1 Approx.Wt.(Lbs.) 4242-007 3/4 1-1/4 1-1/2 1/4 1/2 1-3/8 .08 4242-010 1 1-7/16 1-11/32 5/16 7/32 1-23/32 .14 4242-012 1-1/4 1-9/16 1-25/32 17/32 11/16 2-1/16 .21 4242-015 1-1/2 1-13/32 1-23/32 1/2 11/32 2-11/32 .28 4242-020 2 1-29/32 2-1/8 7/32 5/8 2-7/8 .42 4242-025 2-1/2 2-7/32 2-7/32 15/32 15/32 3-1/2 .68 4242-030 3 2-13/32 2-13/32 9/16 17/32 4-5/32 .99 45° ELBOW Socket x Socket • J #) J H 3 ,....__NA___, Part Number Size H J M Approx.Wt.(Lbs.) 4217-007 3/4 1-11/32 13/32 1-5/16 .07 4217-010 1 1-13/32 3/8 1-5/8 .11 4217-012 1-1/4 1-5/8 3/8 2-1/8 .24 4217-015 1-1/2 1-13/16 7/16 2-13/32 .32 4217-020 2 2-1/8 5/8 2-7/8 .47 4217-025 2-1/2 2-17/32 3/4 3-1/2 .88 4217-030 3 2-29/32 29/32 4-5/32 1.16 Made in the U.S.A. Suitable for Oil-Free air handling to 25 psi,not for distribution of compressed air or gas Page 394 Due to Material Cost Variations,Prices Subject to Change.Check On-line Catalog @ www.spearsmfg.com g FlameGuard®CPVC Fire Sprinkler Products Technical Information SPt�RS FlameGuard() Product Weights & Dimensions- g 45° STREET ELBOW Spigot x Socket H1iA\ J1 M1 Me. H J .-.3.;' � f� e I-' .-I PIPE 0.0. Part Number Size H H1 J J1 M1 Approx.Wt.(Lbs.) 4227-010 1 1-1/2 1-3/8 1/2 11/4 1-5/8 .10 4227-012 1-1/4 1-25/32 1-9/16 9/16 11/32 1-31/32 .15 4227-015 1-1/2 2-1/32 2-1/8 19/32 25/32 2-11/32 .29 4227-020 2 2-5/16 1-15/16 25/32 13/32 2-7/8 .44 CROSS Socket x Socket x Socket x Socket i_ _ retrli;::H.fGI1 ML1 -EA4 _ H1 Fit 0 L I. r —H L—*-- Part Number Size G G1 H H1 L L1 M Approx.Wt.(Lbs.) 4220-007 3/4 5/8 5/8 1-21/32 1-21/32 3-5/16 3-5/16 1-13/32 .22 4220-010 1 3/4 3/4 1-5/8 1-5/8 3-1/4 3-1/4 1-23/32 .23 4220-012 1-1/4 1-1/8 1-1/8 2-3/8 2-3/8 4-3/4 4-3/4 2-3/32 .63 4220-015 1-1/2 1-7/32 1-7/32 2-5/8 2-5/8 5-7/32 5-7/32 2-3/8 .80 4220-020 2 1-1/2 1-1/2 3 3 6 6 3 1.36 4220-025 2-1/2 1-11/16 1-11/16 3-7/16 3-7/16 6-7/8 6-7/8 3-17/32 2.16 4220-030 3 2-3/32 2-3/32 3-31/32 3-31/32 7-15/16 7-15/16 4-7/16 3.37 Pae 395 Suitable for Oil-Free air handling to 25 psi,not for distribution of compressed air or gas Spears®Manufacturing Company g Due to Material Cost Variations,Prices Subject to Change.Check On-line Catalog @ www.spearsmfg.com ik iii , FlameGuard®CPVC Fire Sprinkler Products Technical Information FlameGuard® Product Weights & Dimensions illsfisl REDUCING CROSS Socket x Socket x Socket x Socket '--f-M1 jrj. „.1, ..,... H1 1Li M � G1 G I- . • H L - Part Number Size G G1 H H1 L L1 M M1 Approx.Wt.(Lbs.) 4220-131 1x3/4 23/32 5/8 1-5/8 1-5/8 3-1/4 3-1/4 1-7/8 1-1/2 .31 4220-167 1-1/4x3/4 1-1/16 23/32 2-1/16 1-31/32 4-3/32 3-31/32 2-1/16 1-13/32 .35 4220-210 1-1/2x3/4 11/16 1-5/32 2-3/32 2-3/16 4-3/16 4-11/32 2-3/8 1-13/32 .42 4220-248 2x3/4 11/16 1-7/16 2-7/32 2-7/16 4-13/32 4-7/8 2-29/32 1-13/32 .56 4220-289 2-1/2x1 29/32 1-3/4 2-11/16 2-7/8 5-11/32 5-3/4 3-1/2 1-3/4 .98 COUPLING Socket x Socket F v. ,, 1 M L N L Part Number Size L M N Approx.Wt.(Lbs.) 4229-007 3/4 1-31/32 1-5/16 3/32 .05 4229-010 1 2-3/16 1-5/8 3/32 .08 4229-012 1-1/4 2-19/32 2 3/32 .13 4229-015 1-1/2 2-7/8 2-11/32 3/32 .22 4229-020 2 3-1/8 2-27/32 3/32 .32 4229-025 2-1/2 3-11/16 3-15/32 3/16 .48 4229-030 3 4 4-3/16 1/4 .89 Made in the U.S.A. Suitable for Oil-Free air handling to 25 psi,not for distribution of compressed air or gas Page 396 Due to Material Cost Variations,Prices Subject to Change.Check On-line Catalog l www.spearsmfg.com g 1 FlameGuard®CPVC Fire Sprinkler Products Technical Information SPEARS FlameGuard® Product Weights & Dimensions REDUCER COUPLING Socket x Socket --1- f--,..-v :-.,, ..M1 M1 j ''' 1 $ 1. N L 1 Part Number Size L M M1 N Approx.Wt.(Lbs.) 4229-131 1x3/4 2-3/8 1-23/32 1-13/32 7/32 .10 4229-167 1-1/4x3/4 2-19/32 2-3/32 1-5/8 11/32 .17 4229-168 1-1/4x1 2-11/16 2-3/32 1-23/32 5/16 .18 4229-210 1-1/2x3/4 2-13/16 2-11/32 1-13/32 15/32 .19 4229-211 1-1/2x1 2-7/8 2-11/32 1-15/16 3/8 .24 4229-212 1-1/2x1-1/4 2-13/16 2-13/32 2-1/8 5/32 .23 4229-248 2x3/4 3-3/16 2-7/8 1-7/16 23/32 .32 4229-249 2x1 3-1/8 2-7/8 1-23/32 1/2 .31 4229-250 2x1-1/4 3-3116 2-7/8 2-1/8 17/32 .33 4229-251 2x1-112 3-3/16 2-27/32 2-11/32 9/32 .31 4229-291 2-112x1-112 3-23/32 3-15/32 2-11/32 21/32 .51 4229-292 2-1/2x2 3-21132 3-1/2 2-7)8 13/32 .52 4229-337 3x1-112 3-112 4-3116 2-3/8 7/32 .71 4229-339 3x2-1/2 3-27/32 4-3116 3-1/2 3/16 .80 GripLocTM PUSH-ON COUPLING - LEAD FREE w/EPDM 0-Ring Seals L 175 psi Maximum Push On Compression Internal Pressure @ 150°F .L,. Jr. In= M WARNING: DO NOT INSERT FINGERS. Part Number Size L L1 M Approx.Wt.(Lbs.) GL4229-007 3/4 4 1-9/16 1-15/16 .26 GL4229-010 1 4-1/8 1-15/16 2-1/4 .35 Page Due to Material Cost Variations,Prices Subject to Change.Check On-line Catalog @ www.spearsmfg.com FlameGuard®CPVC Fire Sprinkler Products Technical Information FlameGuard® Product Weights & Dimensions SPEARS GROOVED COUPLING ADAPTERElli Groove x Socket Fill":1, PPE M1 OD. .---N L Part Number Size L M1 N Approx.Wt.(Lbs.) 4233-012 1-1/4 3-5/8 2-3/32 2-11/32 72 4233-015 1-1/2 3-3/4 2-11/32 2-11/32 .83 4233-020 2 3-27/32 2-27/32 2-11/32 1.27 4233-025 2-1/2 4-3/16 3-15/32 2-7/16 2.02 4233-030 3 4-5/32 4-1/8 2-7/16 2.79 Not intended to convey or dispense water for human consumption through drinking or cooking FEMALE ADAPTER I. Brass Thread Insert Style s Socket x Fipt M 1' I 1111 M1 1 11111 N IN L Part Number Size L M M1 N Approx.Wt.(Lbs.) 4235-007 3/4 2 1-13/32 1-3/8 5/16 .23 4235-010 1 2-3/16 1-3/4 1-11/16 11/32 .25 4235-012 1-1/4 2-3/8 2-3/32 2-1/16 3/8 .36 4235-015 1-1/2 2-17/32 2-11/32 2-7/16 3/8 .49 4235-020 2 2-25/32 2-27/32 3-3/16 7/16 1.05 Not intended to convey or dispense water for human consumption through drinking or cooking FEMALE ADAPTER Special Reinforced Plastic Thread Style Socket x SR Fipt I 11'i7 m46:7441,41,„„ A',r I fl a't4i; 1, \I IIIII,I— Part Number Size L M M1 N Approx.Wt.(Lbs.) 4235-007SR 3/4 1-7/8 1-13/32 1-3/8 3/32 .08 4235-010SR 1 2-5/32 1-23/32 1-7/8 3/32 .22 4235-012SR 1-1/4 2-5/16 2-1/8 2-1/16 3/16 .20 Made in the U.S.A. Suitable for Oil-Free air handling to 25 psi,not for distribution of compressed air or gas Page 398 Due to Material Cost Variations,Prices Subject to Change.Check On-line Catalog @ www.spearsmfg.com g FlameGuard®CPVC Fire Sprinkler Products Technical Information I SPEARS FlameGuard® Product Weights & Dimensions I FEMALE REDUCING SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style Socket x SR Fipt ;,-4 f, 0 M M1 Ali l I illN L______ Part Number Size L M M1 N Approx.Wt.(Lbs.) 4235-101SR 3/4x1/2 1-29/32 1-13/32 1-3/16 1/8 .08 4235-130SR 1x1/2 1-15/16 1-23/32 1-3/8 3/32 .16 4235-131SR 1x3/4 2-3/32 1-3/4 1-3/8 1/4 .13 FEMALE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style with Socket Wrench Flats Socket x SR Fipt WO M= Flat-to-Flat Dimension M " �'I M1 N Part Number Size L M M1 N Approx.Wt.(Lbs.) W4235-101SR 3/4x1/2 2-9/32 1-13/32 1-3/16 17/32 .09 W4235-130SR 1x1/2 2-9/32 1-3/4 1-3/16 13/32 .12 FEMALE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread w/Metal Thread Start Socket x SR Fipt 1111 l^ — — —H`1"�� M1 t N—i.- L Part Number Size L M M1 N Approx.Wt.(Lbs.) Z4235-101SR 3/4x1/2 1-7/8 1-3/8 1-7/16 3/16 .08 PaSuitable for Oil-Free air handling to 25 psi,not for distribution of compressed air or gas Spears®Manufacturing Companyge Due to Material Cost Variations,Prices Subject to Change.Check On-line Catalog @ www.spearsmfg.com FlameGuard®CPVC Fire Sprinkler Products Technical Information FlameGuard® Product Weights & Dimensions S`cARS SPIGOT FEMALE ADAPTER Brass Thread Insert Style Spigot x Fipt T i —1_ PIPE - �IIII sill M1 7 _L,3.,..1111,1.11111 r N 4•-► 1 L Part Number Size L M1 N Approx.Wt.(Lbs.) 4278-007 3/4 2-5/32 1-3/8 17/32 .15 4278-010 1 2-9/32 1-11/16 7/16 .22 Not intended to convey or dispense water for human consumption through drinking or cooking SPIGOT FEMALE ADAPTER Special Reinforced Plastic Thread Style Spigot x SR Fipt T 'i4 PIPE ,- _ IifhliI N L Part Number Size L M1 N Approx.Wt.(Lbs.) 4278-007SR 3/4 1-15/16 1-3/8 11/32 .08 4278-010SR 1 2-1/4 1-23/32 13/32 .13 TorqueSafeTM FEMALE SPRINKLER HEAD ADAPTER Gasket Sealed Brass Thread Insert Style Socket x Gasket Fipt With Elastomer Seal-Use NO Thread Sealant i �sow 11 M Lotlailii � M1 IIIIIIIrrarrila N- - L---- Part -Part Number Size L M M1 N Approx.Wt.(Lbs.) 4235-101 G 3/4x1/2 1-7/8 1-13/32 1-3/8 17/32 .15 4235-130GS 1x1/2 2-1/32 1-11/16 1-3/8 17/32 .17 4235-131 G 1x3/4 2 1-11/16 1-9/16 9/16 .18 Not intended to convey or dispense water for human consumption through drinking or cooking Made in the U.S.A. Suitable for Oil-Free air handling to 25 psi,not for distribution of compressed air or gas Page 400 Due to Material Cost Variations,Prices Subject to Change.Check On-line Catalog @ www.spearsmfg.com g FlameGuard®CPVC Fire Sprinkler Products Technical Information SPEARS FlameGuarde Product Weights & Dimensions3 FEMALE SPRINKLER HEAD ADAPTER Brass Thread Insert Style Socket x Fipt mom - slll h► 11 I II• . N-1--►4 i L Part Number Size L M Ml N Approx.Wt.(Lbs.) 4235-101 3/4x1/2 1-7/8 1-13/32 1-17/32 15/32 .19 4235-130 1x1/2 2-11/32 1-11/16 1-3/16 5/8 .16 4235-131 1x3/4 2-5/16 1-11/16 1-3/8 17/32 18 Not intended to convey or dispense water•for human consumption through drinking or cooking SofTorqueTM SR FEMALE SPRINKLER HEAD ADAPTER Gasket Sealed Special Reinforced Plastic Thread Style Socket x SR Fipt With Elastomer Seal-Use NO Thread Sealant L 1,- 1 - I .__ IN C�• I M1 impwillill N Part Number Size L M M1 N Approx.Wt.(Lbs.) 4235-101GSR 3/4x1/2 2-5/16 1-5/16 1-3/8 31/32 .11 4235-130GSR 1x1/2 2-13/32 1-19/32 1-3/8 31/32 .13 4235-131GSR 1x3/4 2-13/32 1-5/8 1-23/32 1 .16 FEMALE SPRINKLER HEAD ADAPTER ,,,,,,,,,,,:“1", . Brass Thread Insert Style M -4 Iti i i M1 with Long Body 1. t1,11Illli Socket x Fipt N —L Part Number Size L M M1 N Approx.Wt.(Lbs.) L4235-130 1x1/2 2-3/16 1-23/32 1-7/32 1/2 .19 Not intended to convey or dispense water for human consumption through drinking or cooking Page 401 DueStuoitrtiteefgar lOCil-oFsrteeVaairriahtaiondnlsin,gPtroc2e5s pSsu,ibnjoetcfor o diChtraibnugteio.nCohf eccokmOrnesisneed Car taorlogas@ wwSpweasrsp®eMaarsnumfafcgtu.rcinogm Company FlameGuard®CPVC Fire Sprinkler Products Technical Information FlameGuard® Product Weights & Dimensions SPEW FEMALE SPRINKLER HEAD ADAPTER Brass Thread Insert Style with Positioning Ring 1tv hw LJ Socket x Fipt M ihif1111 i1 N 61 L Part Number Size L M M1 N Approx.Wt.(Lbs.) R4235-101 3/4x1/2 2-1/32 1-7/16 1-3/16 15/32 15 Not intended to convey or dispense water for human consumption through drinking or cooking FEMALE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style with Positioning Ring1goo "'""' I Socket x SR Fipt Mm„ NA 1 N— L Part Number Size L M M1 N Approx.Wt.(Lbs.) R4235-101SR 3/4x1/2 1-15/16 1-7/16 1-7/32 7/32 .09 TorqueSafeTM FEMALE SPIGOT SPRINKLER HEAD ADAPTER Gasket Sealed Brass Thread Insert Style Spigot x Gasket Fipt . With Elastomer Seal-Use NO Thread Sealant f " I PIPEIlli M1 O.D. iel,ilill 1 N �� L Part Number Size L M N Approx.Wt.(Lbs.) 4238-101 G 3/4x1/2 1-15/16 1-3/8 17/32 .14 4238-130 G 1x1/2 2-1/16 1-3/8 19/32 15 Not intended to conveyor dispense water for human consumption through drinking or cooking SPIGOT FEMALE SPRINKLER HEAD ADAPTER Brass Thread Insert Style Spigot x Fipt _ ,11"""' PIPEi',"':77:.'!-- 1111101111 . ii4 ►ii M1 o. . 4 �ll101��ll� t u.-..J.. I N __ L Part Number Size L M1 N Approx.Wt.(Lbs.) 4238-101 3/4x1/2 2-5/32 1-7/32 19/32 .12 4238-130 1x1/2 2-1/4 1-3/16 11/32 .19 Not intended to convey or dispense water for human consumption through drinking or cooking Made in the U.S.A. Suitable for Oil-Free air handling to 25 psi,not for distribution of compressed air or gas Page 402 Due to Material Cost Variations,Prices Subject to Change.Check On-line Catalog @ www.spearsmfg.com g FlameGuard®CPVC Fire Sprinkler Products Technical Information Fa FlameGuard® Product Weights & Dimensions TorqueSafeTm BUSHING - GASKET SEALED Brass Thread Insert Style Spigot x Gasket Fipt' oda Linn" With Elastomer Seal-Use NO Thread Sealant I IIII PIPE `' .!119 O.D. L Part Number Size L Approx.Wt.(Lbs.) 4238-130BR G 1x1/2 1-5/32 10 Not intended to conveyor dispense water for human consumption through drinking or cooking BUSHING with BRASS THREAD INSERT Spigot x Fipt o■1 o PIPE l [ O.D. t•—L---'1 Part Number Size L Approx.Wt.(Lbs.) 4238-130BR 1x1/2 1 .13 Not intended to convey or dispense water for human consumption through drinking or cooking SPIGOT FEMALE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style Spigot x SR Fipt ,:_ PIP — — II 1 o .+WV ry11111I1I j t«-LSI Part Number Size L M1 N _ Approx.Wt.(Lbs.) 4238-101SR 3/4x1/2 1-29/32 1-7/32 1/8 .07 4238-130SR 1x1/2 2-1/32 1-7/32 7/32 .09 MALE ADAPTER �� With CPVC Lined Thread Brass Insert MiptxSocket ----- --- M1 iiirimini ii I -I N J Part Number Size L M1 N Approx.Wt.(Lbs.) 4236-007 3/4 2-17/32 1-13/32 13/16 .26 4236-010 1 2-15/16 1-23/32 29/32 .43 4236-012 1-1/4 3-1/8 2-3/32 31/32 .66 4236-015 1-1/2 3-9/32 2-11/32 31/32 .80 4236-020 2 3-7/16 2-27/32 31/32 1.00 Pae403 Suitable for Oil-Free air handling to 25 psi,not for distribution of compressed air or gas Spears®Manufacturing Company g Due to Material Cost Variations,Prices Subject trod o Change.Check On-line Catalog @ www.spearsmfg.com FlameGuard®CPVC Fire Sprinkler Products Technical Information FlameGuard® Product Weights & Dimensions 1SPEARS ' ADJUSTABLE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style —Q Socket x SR Fipt `7 N Body L Width L N Part Number Size Q Body Width Approx.Wt.(Lbs.) Min Max Min Max 42001SR 3/4x1/2 6-5/8 8-11/32 4-7/8 6-19/32 1-1/4 2-3/16 .66 42011SR 1x1/2 6-23/32 8-7/16 4-27/32 6-9/16 1-1/4 2-3/16 .69 ADJUSTABLE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style Spigot x SR Fipt _Q PIPE I~–N II I Body ' L r Width L N Part Number Size Q Body Width Approx.Wt.(Lbs.) Min Max Min Max 42004SR 3/4x1/2 6-23/32 8-11/32 4-29/32 6-17/32 1-1/4 2-3/16 .66 42014SR 1x1/2 6-3/4 8-13/32 4-29/32 6-9/16 1-1/4 2-3/16 .67 REDUCER BUSHING Flush Styleu Spigot x Socket PIPE -` ,a$ N I L Part Number Size L N Approx.Wt.(Lbs.) 4237-131 1x3/4 1-1/4 1/4 .04 4237-167 1-1/4x3/4 1-7/16 7/16 .10 4237-168 1-1/4x1 1-13/32 9/32 .06 4237-210 1-1/2x3/4 1-5/8 5/8 .19 4237-211 1-1/2x1 1-17/32 13/32 .13 4237-212 1-1/2x1-1/4 1-9/16 5/16 .07 4237-248 2x3/4 1-29/32 29/32 .28 4237-249 2x1 1-23/32 9/16 .23 4237-250 2x1-1/4 1-11/16 7/16 .21 4237-251 2x1-1/2 1-11/16 5/16 .15 4237-290 2-1/2x1-1/4 2-5/32 7/8 .41 4237-291 2-1/2x1-1/2 2-5/32 3/4 .39 4237-292 2-1/2x2 2-9/32 3/4 .28 4237-338 3x2 2-7/32 11/16 .63 4237-339 3x2-1/2 2-5/16 1/4 .42 Made in the U.S.A. Suitable for Oil-Free air handling to 25 psi.not for distribution of compressed air or gas Page 404 Due to Material Cost Variations,Prices Subject to Change.Check On-line Catalog @ www.spearsmfg.com g FlameGuard®CPVC Fire Sprinkler Products Technical Information 0 1 F R lameGuard® Product Weights & Dimensions TRANSITION BUSHING } IPS Spigot x CTS Socket PIPE `'- O.D 1 L N Part Number Size L N Approx.Wt.(Lbs.) 4240-101 3/4x1/2 1-1/8 5/8 .03 4240-130 1x1/2 1-1/4 23/32 .05 CAP Socket k ..:1,,,.,:?, M fi � . W-i Part Number Size M W Approx.Wt.(Lbs.) 4247-007 3/4 1-3/8 1-13/32 .05 4247-010 1 1-5/8 1-9/16 .06 4247-012 1-1/4 2-3/32 1-27/32 .13 4247-015 1-1/2 2-11/32 2 .17 4247-020 2 2-27/32 2-9/32 .39 4247-025 2-1/2 3-17/32 2-5/8 .50 4247-030 3 4-3/8 3 .92 TEST PLUG - 0-Ring Sealed Mipt-For Pressure Testing Only. Not For use with Gasket Sealed or Z4235 Series Adapters L 1I F7:71:41 1 M1 - M 1/2-14 NPT Part Number Size L M M1 Approx.Wt.(Lbs.) FTP-005 1/2 1-27/32 1-15/16 1-7/32 .03 Pa e 405 Suitable for Oil-Free air handling to 25 psi,not for distribution of compressed air or gas Spears®Manufacturing Company g Due to Material Cost Variations,Prices Subject to Change.Check On-line Catalog @ www.spearsmfg.com FlameGuard®C PVC Fire Sprinkler Products Technical Information FlameGuard® Product Weights & Dimensions FENS TEST PLUG for TorqueSafe' Gasket Sealed Head Adapters Mipt-For Pressure Testing Only. Use ONLY with Gasket Sealed Head Adapters t 1 M1 M 1 1(2-14 NPT Part Number Size L M M1 Approx.Wt.(Lbs.) FTP-005GS 1/2 1-25/32 2-1/32 1-1/4 05 TEST PLUG (PVC White)Not UL Listed Mipt-For Pressure Testing Only. [• L--.--I Part Number Size L Approx.Wt.(Lbs.) 4250-005 1/2 27/32 .02 FLANGE - ONE PIECE 4 Bolt Holes,175 psi Socket r--- M ----'1 L L— ',r--i x - t ii; Er N F I-0— BOLT CIRCLE DIA.---.1 MAX O.D. No.of Bolt Min. Part Number Size L M N R Bolt Circle Bolt Bolt Max. Approx.Wt. Holes Dia. Size Length O.D. (Lbs.) 4251-007 3/4 1-5132 1-1/2 118 17/32 4 2-3/4 112 2 3-29132 .31 4251-010 1 1-5/16 1-13/16 1/8 11/16 4 3-1/8 1/2 2-114 4-9/32 .35 4251-012 1-1/4 1-13/32 2-7/32 5/32 11/16 4 3-1/2 1/2 2-1/4 4-5/8 .44 4251-015 1-1/2 1-19/32 2-1/2 3/16 23/32 4 3-27/32 1/2 2-1/2 5-1/16 .61 4251-020 2 1-27/32 3 5/16 27/32 4 4-3/4 5/8 3 5-31/32 .95 4251-025 2-1/2 2-7/32 3-1/2 7/16 1-1/32 4 5-1/2 5/8 3-1/4 7 1.50 Made in the U.S.A. Suitable for Oil-Free air handling to 25 psi,not for distribution of compressed air or gas Page 406 Due to Material Cost Variations,Prices Subject to Change.Check On-line Catalog @ www.spearsmfg.com FlameGuard®CPVC Fire Sprinkler Products Technical Information MIS. FlameGuard® Product Weights & Dimensions BLIND FLANGE 4 Bolt Holes,175 psi R L 4Imo---- BOLT CIRCLE DIA. —I-1 1 I MAX 0.D. Bolt Circle No.of Bolt Min. Bolt Part Number Size R Dia. Holes Bolt Size Length Max.O.D. Approx.Wt.(Lbs.) 4253-007 3/4 17/32 2-3/4 4 1/2 2 3-27/32 .30 4253-010 1 23/32 3-1/8 4 1/2 2-1/4 4-1/4 .35 4253-012 1-1/4 21/32 3-1/2 4 1/2 2-1/4 4-5/8 .40 4253-015 1-1/2 23/32 3-27/32 4 1/2 2-1/2 5-1/16 .52 4253-020 2 27/32 4-3/4 4 5/8 3 5-31/32 .86 4253-025 2-1/2 1-1/32 5-1/2 4 5/8 3-1/4 6-15/16 1.70 4253-030 3 1-5/16 6 4 5/8 3-1/4 7-5/8 1.72 FLANGE - TWO PIECE Van Stone Style,4 Bolt Holes, 175 psi M Socket Ni —BOLT CIRCLE DIA—.--I MAX 0.D. Bolt Circle No.of Bolt Min.Bolt Max. Approx.Wt. Part Number Size L M N R Dia. Holes Bolt Size Length O.D. (Lbs.) 4254-030 3 2-1/8 4-1/4 9/32 1-1/32 6 4 5/8 3-1/4 7-15/32 1.75 FLANGE - TWO PIECE Van Stone Style,4 Bolt Holes,175 psi Spigot -PIPE O.D. 1 -N L R_ BOLT CIRCLE DIA-0-1 j MAX OD Bolt No.of Min.Bolt Part Number Size L N R Circle Bolt Bolt Size Length Max.O.D. Approx.Wt.(Lbs.) Dia. Holes 4256-007 3/4 1-15/16 13/16 17/32 2-3/4 4 1/2 2 3-27/32 .30 4256-010 1 2-7/32 1-1/32 11/16 3-1/8 4 1/2 2-1/4 4-1/4 .41 4256-012 1-1/4 2-3/8 1 11/16 3-1/2 4 1/2 2-1/4 4-5/8 .50 4256-015 1-1/2 2-7/16 1-3/32 23/32 3-7/8 4 1/2 2-1/2 4-31/32 65 4256-020 2 2-3/4 1-5/32 25/32 4-3/4 4 5/8 3 5-15/16 1.00 4256-025 2-1/2 3-1/16 1-9/32 1-1/32 5-1/2 4 5/8 3-1/4 6-15/16 1.62 4256-030 3 3-3/8 1-13132 1-1/32 6 4 5/8 3-1/4 7-9/16 1.76 Page 407 Suitable for Oil-Free air handling to 25 psi,not for distribution of compressed air or gas Spears®Manufacturing Company g Due to Material Cost Variations,Prices Subject to Change.Check On-line Catalog @ www.spearsmfg.com i FlameGuard®CPVC Fire Sprinkler Products Technical Information FlameGuard® Product Weights & Dimensions PEARS TRANSITION UNION Brass Thread Insert Style 1 7 5 p s i Socket x Fipt r 004 oi':., NUT „,, 0.0 M - rle "IIIIII — N L r Part Number Size L M N Nut O.D. Approx.Wt.(Lbs.) 4259-010BR 1 2-13/16 1-7/8 1-1/32 2-7/8 .52 4259-012BR 1-1/4 3 2-3/16 1-1/8 3-9/32 .98 4259-0158R 1-1/2 3-3/4 2-1/2 1-9/16 3-17/32 .93 4259-020BR 2 3-5/8 2-7/8 1-1/4 4-5/16 1.64 Not intended to convey or dispense water for human consumption through drinking or cooking UNION Socket x Socket 175 psi 1 r i 0 PA NUT M O.D. 1 L 1 .41111 l N t� 5; 1 Part Number Size L M N Nut O.D. Approx.Wt.(Lbs.) 4257-007 3/4 2-3/8 1-17/32 3/8 2-1/2 .38 4257-010 1 2-9116 1-27/32 38 2-7/8 41 4257-012 1-1/4 ,2-27/32 2-7/32 11/32 3-5/16 .52 4257-015 1-1/2 3-1/8 2-112 3/8 3-17/32 .63 4257-020 2 3-5/8 3-1/32 9/16 4-3/16 1.09 QuickTorqueTM SR FEMALE SPRINKLER HEAD ADAPTER Gasket Sealed Special Reinforced Plastic Thread Style Socket x SR Metal Fipt With Elastomer Seal-Use NO Thread Sealant C si M it Ml I.—N-.1 Part Number Size L M M1 N Approx.Wt. 4235-130GMR 1x1/2 2-3/16 1-19/32 1-9/16 15/16 .19 Made in the U.S.A. Suitable for Oil-Free air handling to 25 psi,not for distribution of compressed air or gas Page 408 Due to Material Cost Variations,Prices Subject to Change.Check On-line Catalog @ www.spearsmfg.com g FlameGuard®CPVC Fire Sprinkler Products Technical Information S FlameGuard® Product Weights & Dimensions SofTorqueTM SR FEMALE SPIGOT SPRINKLER HEAD ADAPTER Gasket Sealed Special Reinforced Plastic Thread Style Spigot x SR Fipt With Elastomer Seal-Use NO Thread Sealant --All- :ID PE �� M1 LJ L 1 Part Number Size L M1 N Approx.Wt.(Lbs.) 4278-101GSR 3/4x1/2 2-1/4 1-3/8 1 .11 SHORT REPAIR COUPLING Spigot x Socket 17 i s, i L2 4 L1 I.-0—o—L3 k 1 7 ,, 3 y S Part Number Size L1 L2 L3 M S Approx.Wt.(Lbs.) SH118-07C0 3/4 4-13/16 5-17/32 3/4 1-3/4 2-3/16 .31 SH118-1000 1 4-3/4 5-5/8 31/32 2-1/16 2-5/32 .40 GripLocTM REPAIR COUPLING — LEAD FREE w/EPDM 0-Ring Seals L1 175 psi Maximum L-- g --L Pressure @ 150°F irk;-"T::,. L2 WARNING: DO NOT INSERT FINGERS. Part Number Size L L1 L2 M S Approx.Wt. (Lbs.) SG118-1000 1 1-17/32 7-17/32 4-1/4 2-1/4 2-27/32 .73 Pa e 409 Suitable for Oil-Free air handling to 25 psi,not for distribution of compressed air or gas Spears®Manufacturing Company g Due to Material Cost Variations,Prices Subject to Change.Check On-line Catalog @ www.spearsmfg.com FlameGuard®CPVC Fire Sprinkler Products Technical Information FlameGuard®CPVC True Union Drain & Swing Check Valves for NFPA 13Dg�fgg Applications Only i FlameGuardl CPVC Drain & Swing Check Valves for NFPA 13D Applications Only Application: FlameGuard®CPVC Orange Swing Check Valves and PVC/CPVC True Union Drain Valves are for use in configuring CPVC Fire Sprinkler System connection to water supply(riser/drain assembly)in NFPA 13D installations only.These valves are not UL Listed and NOT for use in any other locations within the fire sprinkler system. TRUE UNION INDUSTRIAL DRAIN VALVES CPVC Gray Valve with CPVC Orange End Connector Socket x Socket E r I • � • D I ii1 A1I�I W1W.IML-rda I B C r Part Number Size A B C D E 1822-007CFG 3/4 2-1/4 2-3/4 4-3/4 2-7/8 3-3/8 1822-010CFG 1 2-1/2 2-7/8 5-1/8 3-1/8 3-7/16 1822-012CFG 1-1/4 3-1/16 3-1/4 5-3/4 3-5/8 3-7/8 1822-015CFG 1-1/2 3-1/2 3-1/2 6-1/4 4 4-3/16 1822-020CFG 2 4-1/4 4-3/4 7-3/4 4-1/2 5-1/8 Not UL Listed TRUE UNION DRAIN VALVES PVC Valve with CPVC End Connector Socket x Socket E -+I 1 D A ®r MI III B C r Part Number Size A B C D E 3622-007FG 3/4 2-1/4 2-3/4 4-3/4 2 3 3622-010FG 1 2-1/2 2-7/8 5-1/8 2-5/16 3-7/16 Not UL Listed Made in the U.S.A. Suitable for Oil-Free air handling to 25 psi,not for distribution of compressed air or gas Page 410 Due to Material Cost Variations,Prices Subject to Change.Check On-line Catalog @ www.spearsmfg.com g FlameGuard®CPVC Fire Sprinkler Products Technical Information I- , I' R FlameGuard®CPVC True Union Drain & Swing Check Valves for NFPA 13D Applications Only i CPVC SWING CHECK VALVES Socket x Socket ammu A ' D 4_ 1 I C........)"--__I lam_B i-.. C ► Part Number Size A B C D Approx.Wt.(Lbs) S1520-1000 1 1-11/16 2-5/16 4-9/16 2-5/8 .33 S1520-12C0 1-1/4 2-1/16 2-15/16 5-1/2 3-3/8 .42 S1520-15C0 1-1/2 2-7/16 3 5-5/8 3-3/8 .89 Not UL Listed CPVC SPECIAL REINFORCED THREAD INLET SWING CHECK VALVES SR Fipt x Socket it 1A -----.III�� k �® D Mil MICIINglenalli. B-P.- C Part Number Size A B C D Approx.Wt.(Lbs) S1520-10FSRSCO 1 1-11/16 2-15/16 4-9/16 2-5/8 .33 S1520-12FSRSCO 1-1/4 2-1/16 3-5/8 5-1/2 3-3/8 .42 S1520-15FSRSCO 1-1/2 2-7/16 3-11/16 5-5/8 3-3/8 .89 Not UL Listed { PagePacompressed air or gas Spears®Manufacturing Company Due to Material Cost Variations,Prices Subject to Change.Check On-line Catalog @ www.spearsmfg.com PACIFIC STATES PSCIPCO CAST IRON PIPE COMPANY DIVISION OF McWANE,INC. P.O. BOX 1219, PROVO, UTAH 84603 TELEPHONE(AREA CODE 801)373-6910 Mechanical Joint with Tyton® Joint Thickness, Dimensions and Weights of MJ/TJ Joint Ductile Iron Pipe by size for Each Thickness Wt. of Nominal Nominal Barrel Wt. of Wt. Per Nom. Wt. Laying** Thickness Thickness OD* Per Ft. t Bell Lgth.t Per Ft.$ Length Size Class In. In. Lb. Lb. Lb. Lb. Ft. 6 50 .25 6.90 16.00 29 315 17.71 6 51 .28 6.90 17.80 29 345 19.37 6 52 .31 6.90 19.60 29 380 21.30 6 53 .34 6.90 21.40 29 410 22.95 6 54 .37 6.90 23.20 29 445 24.88 6 55 .40 6.90 25.00 29 475 26.54 6 56 .43 6.90 26.70 29 505 28.19 18.125 8 50 .27 9.05 22.80 51 445 25.431 8 51 .30 9.05 25.20 51 490 27.64 8 52 .33 9.05 27.70 51 535 30.12 8 53 .36 9.05 30.10 51 575 32.61 8 54 .39 9.05 32.50 51 620 35.09 8 55 .42 9.05 34.80 51 660 37.30 8 56 .45 9.05 37.20 51 705 39.78 18.125 10 50 .29 11.10 30.10 66 590 33.60 10 51 .32 11.10 33.20 66 645 36.91 10 52 .35 11.10 36.20 66 695 39.94 10 53 .38 11.10 39.20 66 750 42.70 10 54 .41 11.10 42.10 66 805 45.74 10 55 .44 11.10 45.10 66 860 48.77 10 56 .47 11.10 48.00 66 910 51.53 18.125 12 50 .31 13.20 38.40 79 750 42.21 12 51 .34 13.20 42.00 79 815 45.79 12 52 .37 13.20 45.60 79 880 49.66 12 53 .40 13.20 49.20 79 945 53.24 12 54 .43 13.20 52.80 79 1010 56.55 12 55 .46 13.20 56.30 79 1070 59.86 12 56 .49 13.20 59.90 79 1135 63.45 18.125 14 50 .33 15.30 47.50 148 935 54.90 14 51 .36 15.30 51.70 148 1010 59.31 14 52 .39 15.30 55.90 148 1085 63.45 14 53 .42 15.30 60.10 148 1160 67.59 14 54 .45 15.30 64.20 148 1235 71.72 14 55 .48 15.30 68.40 148 1310 75.59 14 56 .51 15.30 72.50 148 1385 79.72 18.125 1-Including bell;calculated weight of pipe rounded off to the nearest 51b. *Tolerances of OD of spigot end;3-12 in.±0.06 in., 14-24 in. *Including bell;average weight per foot, based on calculated weight of +0.05 in.,-0.08 in. pipe before rounding. **Average lengths only. Variances may occur as a result of foundry processes or installation. Pacific States Cast Iron Pipe Company Mechanical Joint With Tyton® Joint Thickness, Dimensions and Weights of MJ/TJ Joint Ductile Iron Pipe by size for Each Thickness Wt. of Nominal Nominal Barrel Wt. of Wt. Per Nom. Wt. Thickness Thickness OD* Per Ft. t Bell Lgth.t Per ft.$ Laying** Size Class In. In. Lb. Lb. Lb. Lb. Length 16 50 .34 17.40 55.80 74 1100 60.69 18.125 16 51 .37 17.40 60.60 74 1185 65.38 18.125 16 52 .40 17.40 65.40 74 1270 70.07 18.125 16 53 .43 17.40 70.10 74 1355 74.76 18.125 16 54 .46 17.40 74.90 74 1445 79.72 18.125 16 55 .49 17.40 79.70 74 1530 84.41 18.125 16 56 .52 17.40 84.40 74 1615 89.10 18.125 18 50 .35 19.50 64.40 85 1270 70.07 18.125 18 51 .38 19.50 69.80 85 1365 75.31 18.125 18 52 .41 19.50 75.20 85 1465 80.83 18.125 18 53 .44 19.50 80.60 85 1560 86.07 18.125 18 54 .47 19.50 86.00 85 1660 91.59 18.125 18 55 .50 19.50 91.30 85 1755 96.83 18.125 18 56 .53 19.50 96.70 85 1850 102.07 18.125 20 50 .36 21.60 73.50 98 1445 79.72 18.125 20 51 .39 21.60 79.50 98 1555 85.79 18.125 20 52 .42 21.60 85.50 98 1665 91.86 18.125 20 53 .45 21.60 91.50 98 1770 97.66 18.125 20 54 .48 21.60 97.50 98 1880 103.72 18.125 20 55 .51 21.60 103.40 98 1985 109.52 18.125 20 56 .54 21.60 109.30 98 2090 115.31 18.125 24 50 .38 25.80 92.90 123 1830 100.97 18.125 24 51 .41 25.80 100.10 123 1960 108.14 18.125 24 52 .44 25.80 107.30 123 2090 115.31 18.125 24 53 .47 25.80 114.40 123 2215 122.21 18.125 24 54 .50 25.80 121.60 123 2345 129.38 18.125 24 55 .53 25.80 128.80 123 2475 136.55 18.125 24 56 .56 25.80 135.90 123 2605 143.72 18.125 tlncluding bell; calculated weight of pipe rounded off to the nearest 51b *Tolerances of OD of spigot end;3-12 in.±0.06 in., 14-24 in. Including bell; average weight per foot, based on calculated weight of +0.05 in.,-0.08 in.,30-36 in.+0.08 in.,-0.06 in. pipe before rounding. **Average lengths only. Variances may occur as a result of foundry processes or installation. CPVC Fittings Section 51 CPVC Fittings MEM PFS Mfg. Description Pack Number Number , RE ABBREVIATIONS FIP =Female Pipe Thread BlazeMaster GVD =Grooved MIP =Male Pipe Thread 5 =Slip SPG =Spigot CPVC Fittings Made from BF Goodrich BiazeMasterTM resin, a lough thermoplastic material with exceptional heat resistance and hydraulic capabilities, UL Listed and FM Approved. 9Q° Elbows 511121 4206-007 3/4" -SXS 240/30 511122 4206-010 1" -SXS 160/20 511123 4206-012 1-114" -SXS 10 511124 4206-015 1-1/2" -SXS 10 511125 4206-020 2" -SXS 25 511126 4206-025 2-1/2" -SXS 5 90° Elbows - Reducing 511147 4207-101S 3/4"X 1/2" -SXFIP 20 511150 4207-1305 1"X 1/2" -SXFIP 10 q7) 511151 4206-131 1"X 314" -SXS 20 45° Elbows 511201 4217-007 3/4" -SXS 120 0 511202 4217-010 1" -SXS 15 511203 4217-012 1-1/4" -SXS 10 511204 4217-015 1-1/2" -SXS 10 511205 4217-020 2" -SXS 10 511206 2-1/2" -SXS 5 Tees Tees are read straight through and , 2 then outlet-1,2,3, 3 511001 4201-007 3/4" -SXSXS 15 511002 4201-010 1" -SXSXS 15 511003 4201-012 1-1/4" -SXSXS 10 511004 4201-015 1-1/2" -SXSXS 10 511005 4201-020 2" -SXSXS 10 511006 4201-025 2-1/2" -SXSXS 20 — 511007 4201-030 3" -SXSXS 5 511095 4202-010 1" -SXSXFIP 10 511104 1" -SXSXFIP 30 511011 1/2"X 1/2"X 1" -FXFXS 10 FERGUSON'dof •Supplier Of Quality Fire Protection Products To The Trade• Fila&Fabriozhbia . 51-1 CPVC Fittings Section 51 CPVC Fittings PFS Mfg. Description Pack Number Number - PUOSI Tees - Reducing Tees are read straight through and 2 BlazeMaster� r then outlet-1,2,3. T 3 11 511012 4201-102 3/4"X 3/4"X 1" -SXSXS 15 511035 4201-125 1"X 3/4"X 3/4" -SXSXS 15 511036 4201-126 1"X 3/4"X 1" -SXSXS 15 511040 4201-131 1"X 1"X 3/4" -SXSXS 15 511044 4201-157 1-1/4"X I"X 3/4" -SXSXS 15 511045 4201-158 1-1/4"X 1"X 1" -SXSXS 15 511046 4201-159 1-1/4"X 1"X 1-1/4" -SXSXS 15 511052 4201-167 1-1/4"X 1-1/4"X 3/4" -SXSXS 15 511053 4201-168 1-1/4"X 1-1/4"X 1" -SXSXS 15 511054 4201-169 1-1/4"X 1-1/4"X 1-1/2"-SXSXS 10 CE:1 511058 4201-202 1-1/2"X 1-1/4"X 1" -SXSXS 10 511057 1-1/2"X 1-1/2"X 1-1/4"-SXSXS 10 511060 4201-210 1-1/2"X 1-1/2"X3/4" -SXSXS 10 511061 4201-211 1-1/2"X 1-1/2"X 1" -SXSXS 10 511063 4201-213 1-1/2"X 1-1/2"X 2" -SXSXS 10 511070 4201-248 2"X 2"X 3/4" -SXSXS 10 511071 4201-249 2"X 2"X 1" - SXSXS 10 511073 4201-251 2"X 2"X 1-1/2" -SXSXS 10 511076 2-1/2"X 2-1/2"X 1" -SXSXS 10 511081 4201-339 3"X 3"X 2-1/2" -SXSXS 5 511100 4202-1O1S 3/4"X 3/4"X 1/2" -SXSXFIP 50 511101 4202-126S 1"X 3/4"X 1/2" -SXSXFIP 50 0 511102 4202-130S 1"X 1"X 1/2" -SXSXFIP 50 511110 1"X 1/2"X 1" -SXFIPXS 50 511105 4202-1565 1-1/4" X 1"X 1/2" -SXSXFIP 15 511107 4202-166S 1-1/4"X 1-1/4" X 1/2" -SXSXFIP 15 511112 4202-199S 1-1/2"X 1-1/4"X 1/2" -SXSXFIP 10 511114 1-1/2"X 1-1/2"X 1" -SXFIPXS(BRASS) 1 511115 2"X 1-1/2"X 1/2" -SXSXFIP(PLASTIC) 10 511116 4202-247S 2"X 2"X 1/2" -SXSXFIP 10 Crosses 511231 4220-007 3/4" -SXSXSXS 15 511232 4220-010 1" -SXSXSXS 15 - 511233 4220-012 1-1/4" -SXSXSXS 10 .■II 4220-015 1-1/2" -SXSXSXS 5 511235 4220-020 2' -SXSXSXS 5 11111511240 4220-131 1"X 3/4" -SXSXSXS 15 Caps 511801 4247-007 3/4" -S 25 511802 4247-010 1" -S 15 511803 4247-012 1-1/4" -S 10 511804 4247-015 1-1/2" -S 10 511805 4247-020 2" -S 10 511807 4247-025 2-1/2" -S 5 511806 4247-030 3" -S 5 tytFERGUSON' •Supplier Of Quality Fire Protection Products To The Trade• �IFre&Thbriartim,Iuc o� 51-2 CPVC Fittings Section 51 CPVC Fittings PFS Mfg. Description Pack Number Number Mil Couplings BlazeMaster�; 511301 4229-007 3/4" -SXS 15 511302 4229-010 1" -SXS 15 511303 4229-012 1-1/4" -SXS 10 511304 4229-015 1-1/2" -SXS 10 511305 4229-020 2" -SXS 10 111 II 511306 4229-025 2-1/2" -SXS 5 511315 4229-131 1" X 3/4"-SXS 15 511318 4229-168 1-1/4"X 1" -SXS 25 511319 4229-212 1-1/2"X 1-1/4" -SXS 1 Couplings - Reducing Head Adapter 511500 4235-101SR 3/4"X 1/2" -ADAPT-PLASTIC 50 511400 4235-1015 3/4"X 1/2" -SXFIP -BRASS 50 511502 4235-130SR 1"X 1/2" -ADAPT-PLASTIC 50 MINI511402 4235-1305 1"X 1/2" -SXFIP -BRASS 50 511410 4235-1315 i"X 3/4" -SXFIP 50 511315 4229-131 1"X 3/4" -SXS 15 Bushings 511600 4237-131 1"X 3/4" -SXS 50 511602 4237-167 1-1/4"X 3/4" -SXS 25 511603 4237-168 I-1/4"X 1" -SXS 25 mis _i 511604 4237-210 1-1/2"X 3/4" -SXS 25 511605 4237-211 1-1/2"X 1" -SXS 25 511606 4237-212 1-1/2"X 1-1/4" -SXS 25 511612 4237-248 2"X 3/4" -SXS 10 ii11 . 511613 4237-249 2"X 1" -SXS 10 511615 4237-250 2"X 1-1/4" -SXS 10 511623 4237-251 2"X 1-1/2" -SXS 10 511650 4237-292 2-1/2"X 2" -SXS 10 511670 4237-338 3"X 2" -SXS 10 511640 4237-339 3"X 2-1/2" -SXS 10 511690 4238-101S 3/4"X 1/2" -SXFIP 50 .III IIH 511702 4238-130S 1"X 1/2" -SPGXFIP 50 511716 42001 3/4"X 1/2" -SXF 10 511720 42004 3/4"X 1/2" -SXF 10 511718 42011 1" X 1/2" -SXF 10 Unions 511932 4257-010 1" -SXS 10 ME 511933 4257-012 1-1/4" 5 0 FERGUSON` •Supplier Of Quality Fire Protection Products To The Trade• Fire&FnbncatibitInc .20. 51-3 CPVC Fittings Sectionc CPVC Fittings, Cement & CPVC Pipe PFS Mfg, Description Pack tEl Number Number B1azeMaster; Female Adapters 511380 4235-007 3/4" -SXFIP 15 511391 51139 4235-010 1" -SXRP 15 4235-012 1-1/4" -SXFIP 15 1111111111 511392 4235-015 1.1/2" -SXFIP 10 511393 4235-020 2" -SXFIP 5 Ma Female Adapters -Adjustable 511720 3/4"X 1/2"-SPGXFIP 10 III 511721 42014 1"X 1/2" -SPGXFIP 10 6-: Grooved Adapters 511953 4275-012 1-1/4" -SXGVD 10 511954 4275-015 1-1/2" -SXGVD 10 511955 4275-020 2" -SXGVD 5FII 511956 4275-025 2-1/2" -SXGVD 5 Glue Dauber Replaces worn or lost dauber for solvent cement or primer. 512025 997-0301 1-1/2"-QUART CANS 1 .A lk 1-Step Low VOC CPVC Cement Used to solvent weld the joints between CPVC pipe and fittings.Low VOC. — =-- 512030 FS4-020 PINT 12 24« 512031 FS4-030 QUART 12 Teflon®Paste for CPVC Thread sealant used with CPVC threaded fittings only. .2..8 512040 PT-BLUE 75-THREAD SEALANT 12 CPVC PIPE CPVC is a plastic pipe used for fire protection application In \ictaulic residential homes. 'Lica 073021 3/4" X 15' 9000'/LIFT 450 073022 1" X 15' 5100'/LIFT 255 073023 1-1/4" X 15' 4200'/LIFT 210 073024 1-1/2" X 15' 2475'/LIFT 165 rcr• tYYINIIII, 073025 2" X 15' `kAse '�' 1800'/LIFT 75 �0: 073026 2-1/2" X 15' 900'/LIFT 60 073027 3" X 15' 720'/LIFT 45 ,r FERGUSON •Supplier Of Quality Fire Protection Products To The Trade• es FERGUSON' . 51-4 90° ELBOW i"sr,ANVIL Ductile Iron MATERIAL SPECIFICATIONS Ductile iron threaded Fittings are UL& ULC Listed & ;i� 1 , ) FM Approved for 500 psi service. - a- t `7`/l 7 Ductile iron per ASTM A536 Class 65-45-1 2. i v, Dimensions conform to ASME B16.3 Threads ore NPT per ANSI/ASME B 1.20.1. NOTKE:Ductile iron fittings have higher tensile strength*ion that of std pipe.Therefore,over tightening con cause damage to pipe threads which may cause leakage.Ductile iron fittings should be tightened three turns beyond hand tight,but no more than{our turns. c@Si < th U APPROVED ra=tat s1panviv ins tb turrris90.. ELBOW e�arrawai.wv c or masa to Mur'Sale*Riarisioratnic Nominal Size Max.Working Dimensions Approx. Pressure• A B Wt.Eorh i.—A.-1 , In.tmml PSI t 1�1 b.`(mint kr.(nes lbs.OBI 1 _ .� 500 150 1.50 0.62 500 175 1.75 09. ., 1 . 90 t r - W 500 1.94 1.94 1.20 B i 2 500 225 2.25 1.85 A—working Pressure Ratings ors for reference only and bawd on Sat 40 pipe.For Ills(vest 1.11/ULC, and FM pressure ratings versus pipe schedule,please visit orwwlintl.cont or contact your local Anvil Representative. 45° ELBOW :)AFAn ►tL CCIDF/RNVIL ) Ductile Iron MATERIAL SPECIFICATIONS r \� Ductile iron threaded Fittings are UL& ULC Listed & FM Approved for 500 psi service. "- 414.. 1 Ductile iron per ASTM A536 Class 65-45-12. Dimensions conform to ASME 816.3 Threads ore NPT per ANSI/ASME B1.20.1. NOTICE:Ductile iron fittings have higher tensile strength than that of steel pipe.Therefore,over tightening con cause damage to pipe threads which may cause leakage.Ductile iron fittings should be tightened three turns beyond hand fight,but no more than for toms,�fj��'�� c&s fM UMW APPROVED 45° ELBOW i, r«"' m444 r Awe pars Fiftvisonteb. Nominal Sin Max.Working Dimensions Approx. Pressure. A B Wt.Each h.ha* PSS NW tn.fin) it ttttrA) tea.Op) 1 500 1.12 1.12 0.46 �� 11i 500 1.29 1.29 0.73 ,v'( „'r A 1.'i 500 1.43 1.43 092 .t.____I i 1 2 500 1.66 1.a 1.50 .-Working Pressure Ratings ore for reference only and bused on$ch.dD pipe.For the loteit UL/UIC, and FM pressure ratings versus pipe schcdvle,please visit onvuintl.com or contact your local Anvil Representot,ve. STRAIGHT TEE \... _)? • •• . --- , (C(i—pF/FiNvii Ductile Iron ....„ MATERIAL SPECIFICATIONS Ductile iron threaded Fittings are Ul.& ULC Listed & -- -.- FM Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-12. Dimensions conform to ASME B16.3 Threads are NPT per ANSI/ASME B1.20.1. NOTICE:Duchlo iron fngs have higher tensile strength than that of steel pipe.Therefore,over tightening con corse damage to pipe ihremis which may cause leakage.Ductile iron fngs should be tightened three turns beyond hand tight,but no more than lour turns CC)II 4 UM APPROVIO F v Ush,),ALVvia4 DOM,and litvOrOCra STRAIGHT TEE MY.041:4)SIM at owcanvint corn at Nominal Size Max.Working Dimensions Approx. Pressure. 1 A 8 Wt.Each ra.urimi PSI tkPo) la tmat) Ia.OW ltd.(iit) t 1•11111111111 _.„_ _ _ 1 500 1.50 1,50 0.85 1 B 1, : . . 1 yi 500 1.15 1.15 1.22 1 i 500 1.94 1,94 1.55 ii k—A--.-",-..—A---1 2 500 2.25 2.25 2.45 A-Working Pressure Ratings ore for reFecome on and based on&II 40 pipe.For the low UVUtC, and FM pressure ratings versos pipe schedule,please visit onvilinicom or contact your local Anvil Representative. BUSHINGS 1 - 11nwIL i�wvJ� Ductile Iron MATERIAL SPECIFICATIONS •: i"7,-.. Ductile iron threaded fittings are UL& ULC Listed & FM Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-12. Dimensions conform to ASME B16.14 Threads are NPT per ANSI/ASME B1,20.1. NOTICE:Ductile iron fittings have higher tensile strength than Iha+of steel pipe,There/ore,over tightening can cause damage to pipe threads which may corse leakage.Ductile iron fittings should be tightened three turns beyond hand tight,but no more than four turns,�� c® FM tittle APPROVtO r o•Usl gs Appcn4 Deists and Lmsa4o-, BUSHINGS »yr *abaft p» an.-armor -.- -. ocnu.:i an Arne S. RtVauninatn., Neriine!Size Hex.Working' DimensionsStile Approx. Pressure• A i B ( WI.Each kr.(evi) PSI Oki ta.(ntm) fa Onmi h:(kW t6s,IV C ix vi 500 0-75 0.25 1,42 Outside 0.22 r i B 25x15 ._ . 1 x 4 500 0.75 0.25 1.42 Outside 0.17 - 1 A 25x70 t.3., 114 x 1 500 0.80 0.28 1.76 Outside 0.28 Inside Head 7.i.74 ,, '; .-- l • '0 �. 1'. x l 500 0.83 0.31 2.00 Outside 0.45 I A.x I'h 500 0.83 0.31 2.00 Outside 0.30 C 343.: _ l # B 2 x 1 500 0.88 0"41 1.95 inside 0.67 - i ; 2x 1% 500 0.88 0.34 2.48 Outside 0,73 .i4K' :.,"...i: e, . - Outside Head 2 x 1A 500 0.88 0.34 2.48 Outside 0.61 ♦-Working Pressure Ratings ore for reference only and based on Sch.40 pipe.For she loses(ULNLC, and FM pressure ratings versus pipe schedule,please visit arM1intl,cons or contact your local Anvil Representative. GAP L7rialwill:. OC-pF/Fir. Ductile Iron MATERIAL SPECIFICATIONS Ductile iron threaded fittings ore UL& ULC Listed & FM Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-,45-12. Dimensions conform to ASME B16.14 Threads are NPT per ANSI/ASME 81.20.1. NOTICE:Ductile iron Fittings have higher tensile strength than that of steel pipe.Therefore,over tightening ton cause damage to pipe threads which may cause leakage.Ductile iron Fittings should be tightened three turns beyond hand light,but no more than Four turns, UM APPROVED CAP iv,lairwaoprocia Woo and lanomorn vac av lobar row an a cc woo an mor Saba Raposaratonk Nominal Size Max.Working Dimensions Approx, Pressure* ), Wt.Each h..(rwo) PSI(kPo) la(ma) abs.(&gt 1 500 1.1b 0.32 f :u Q1p 1i 500 1,28 0,43 IIIIIIII 500 1.33 0.60 • 2 500 1.45 0.91 A—1A+artcirsg Pressure Ratings ore For reference only and based on Sch.AO pipe For the laical U1/UIC, and FM pressure ratings verws pipe schedule,please visit orrviiintl.00m or tont c$your local Anvil Repressentotive. COUPLING z i/SNviL (CC-PF/RNVIIID Ductile Iron MATERIAL SPECIFICATIONS Ductile iron threaded fittings are UL& ULC Listed & FM Approved for 500 psi service. Ductile iron per ASTM A536 Class 65.45-12. Dimensions conform to ASME 816,14 Threads are NPT per ANSI/ASME B1.20.1. NOTICE:Ductile iron fittings hove higher tensile strength than that of steel pipe.T evefore,over lightening con cause damage to pipe threads which may cause leakage.Ductile iron fittings should be tightened three turns beyond hand light,but no more than four tams, e®tin Q► IIaN APPROVED ` ngs,Am t ° edLnCOUPLING rutna v u»wanvlktldn m a MAW an kwr SWs Flopnasontarno Nominal Size Max.Working Dimensions Approx. Pressure. A WI.Each ie.Am) ?SP(kA? kc(nth) 1 500 1.67 0.40 f ' 1;. 500 1.93 0.57 --- 3 .. i 500 1,15 0.75 2 500 2.53 1.15 A—toning Pressure Ratings ore for reference only and based on Sdr,ata pipe.For the latest UVULC, and FM pressure ratings versus pipe schedule,please visit an rii ntl.corn Or contort your local April Representative. Q CROSS :; AP VIL V j,) Ductile Iron MATERIAL SPECIFICATIONS Ductile iron threaded fittings are Lit.&ULC Listed & FM Approved for 500 psi service. -s; Ductile iron per ASTM A536 Class 65-45-12. Dimensions conform to ASME 816.3 # 9F � ;: fI%�//'- Threads are NPT per ANSI/ASME B 1.20.1_ � r f �( ,.rY a ( NOTICE:Docttle iron fittings have higher tensile strength than that of steel .4 z,t ' pipe.Therefore over tiOstening con cause drmnoge to pipe&mods which may souse leakage.Ductile iron fittings should be tightened three turns beyond hand tight,but no marc than Sour tens, t®Vi sir" ISM APPROVE0 Fa int s'*et pawls sne LmtsNs,s CROSS "sK..r.'"'t..,rw,,.n..`°n," otatsei art t om . Max.Working Dimensions Approx. Nominal Size Pressure. A f S WI.Each As Noll PSI(LPo) In,(OW As(nxr) an.(kg) 1 500 1.50 1.50 0.98 i • 500 1.75 1.75 1.50 -+-B--. .--B ---. 44,45 t —1111.11111.111111 t tib 1 500 1.94 1.94 1.90 A h7 rc + i. 2 5002.25 2.25 2.95 1.3-0A I 1 x 1 500 1.58 1.67 1.27 .,A 25 , . 40.13 42.41 0.58 4 moms 1A x 1 500 1.65 1.80 1.48 i 40x25 41.91 45/2 D.a7 2 x 1 500 1.73 2.02 2.10 A Working Pressure Ratings Ore hr refeeePke 0*and based on 5th.40 pipe.Far Ow latest ULJULC. and FM pressure ratings versus p.pe schedule,please visit orwiintl.corn a-Conrad ypu'local Anv,1 Representative, REDUCING 900 ELBOW 1r /&11IVIL .,.............._ ((((spF/RNviL)))) Ductile Iron MATERIAL SPECIFICATIONS Ductile iron threaded fittings ore UL&ULC Listed & i 1 FM Approved for 500 psi service. r„ .... 't i` - , ''. ikjii. Ductile iron per ASTM A536 Class 65-45-12. -...,, Dimensions conform to ASME 816.3 Threads ore NPT per ANSI/ASME 81.20.1. ----- NOTICE:Ductile iron fittings have higher tensile strength than thoi of steel pipe.Therefore,over tightening con cause clornoge to pipe threads which may cause leakage.Ductile iron kings should be tightened three turns beyond hand tight,but no more than lour turns. CODIll '4:: Mtn APPROVED f te ultrip./wpm&(Mak inl I.Mti1447,4 REDUCING 90° ELBOW vat otr**Wile it wor*Amitoll tan or • 0:01ftel kr,Armr Sitikt Ricoimolkt.. Nominal Size MDX.Working Dimensions Approx. . r---- rressure. A B WI.Emil i.fmm) P9 aPoi k far) it tion) ibs,Che ... 1 x v, 500 1.26 1.36 0.44 1, 500 137 1.45 0.52 -.—8—,– i , . - •.''. 34 79 !..."i'.',.4 ' - .....c– 1 500 1.34 1.53 0.64 ;',hr.i 500 145 142 032 A l'A x 1 500 1.58 1.67 0.75 1.7i.x 1 500 -I 1.65 1.'or 0.92 Wili1/2 500 1.82 1,;t 1.08 1.08 2x Yi 500 1.60 1,97 1.24 2x 1 500 1.73 2.02 1.40 2 x 11/4 500 1.90 2.10 1.52 2 x 11/2 500 2.02 2.16 1.65 •-Working Pressure Ratings ore for reference otiky and based on Sch.40 pipe.For iie latest Llt../ULC., and FM pressure noting%versus pipe schedule,please visit otwilireltasni or coreoci your local Amil Reprerentative. REDUCING COUPLING 'Z Anvil 4C(C—PF/FINVI Ductile Iron MATERIAL SPECIFICATIONS • Ductile iron threaded fittings are UL& ULC Listed & FM Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-12. Dimensions conform to ASME B16.3 Threads are NPT per ANSI/ASME B1.20.1. NOTICE:Ductile iron fittings have higher tensile strength than that of steel pipe.Therefore,over liglsieesing con cause domoge to pipe threads which may cause leakage.Ductile iron fittings should be tightened three turns beyond hond light.but no more then lour turns, egg Q LEM APPROVED REDUCING COUPLING Kuoat rxgs mY(A eat..arvweasan at et tomo cr contact an kne r Sanas Raohaertxrct tiominol Size Max.Working Dimensions Approx. Pressure. Wl.Each tv(mat) PSI(k ) in.(mi) lir,(kg) • 10: A 500 1.69 039 A 1 x at 500 1,69 0.53 -Waning Pressure Ratings ore for reference only and based on Soh.40 pipe.For the latest UtfULC, and FM pressure ratings versus pipe schedule,please visit onriliml.cons or contact your local Anvil Rapresentotive. REDUCING TEE r Ductile Iron MATERIAL SPECIFICATIONS t eta• Ductile iron threaded fittings are UL& ULC Listed & C FM Approved for 500 psi service. - Ductile iron per ASTM A536 Class 65-45-U. Dimensions conform to ASME 316,3 I--A--:--B Threads ore NPT per ANSI/ASME 81.20.1, REDUCING TEE NOTICE:Ductrle iron fittings have higher tensile shenyth than that of steel pipe.Therefore,over tinh tening can cause do age to pipe thsreads which MOX: Dimensions may cause leakage.Ductile iron fittings should be tightened three turns Nominal Size Working Approx. bcyood hand tight,but no more then four tura, + - Pressure. d B ( Wt.Each ce. . › M.0Th P9 07 fn.Ow) _b S4 fr.form) In.rant) lbs.(kg) mu AppR.,oveu 1020 500 1.50 1.36 1-50 0.64 `O1 '°'"44.0. tWilkWKSL.W"°"n NW at �a x,.. on s oor 1 x 94 x 1 500 1.50 1,45 150 0.73 22xi06,, 0L ' REDUCING TEE 1 x 1 x 9S 500 1.26 1.26 1.36 0,71 25x25x/5 '1.54 �:° 1 x I x#4 Max. Dimensions rox. 500 137 1.31 1.45 16 ®aminal Size Working WtA[a b ,5. 0 as. ?6.53 1 x 1 x /� 500Pressure. r' B C 1.67 1.67 1.5$ 0.98 - -_I l x I x 11 . 540 1.80 1.80 1.65 1.16 ht.t`mmi P511LFii) fn.(rem; k front) it.! tbs.(41 1 .x 1 x` 500 1.53 1.52 1.75 1-24 1ii x 1 x Yx 500 1.34 1.26 1.53 0.82 _ 61 x ; x l 500 1.65 1.65 1.80 1.30 1',1x500 1.45 1.37 1.62 0,90 a • '`ft , I x 1 x 1:# 500 1.82 1.82 1.88 1.48 ` 1 x 1;1 500 1.56 - 1.50 1.67 1.00 3450 "? 4.t t i `"x,' 4-% 4" 1 xI,x2 S00 2.16 2.16 2.02 1 98 116x1x1,4 500 135 1.61 1.15 Lt; 1sr,�: 2x7 � 1 . '-- 4 :. -14..4 049 �2x1x2 500 ' 2:25 2.02 2,25 2.15 194 x l x 1' 500 1.86 1.80 1.82 1.42 2 x l ,x 2 , -500 2.25 210 7,"x 25 a 3455 45l; 46.?: a.¢� t 225 - 2.30 lthxl!6x 500 1.34 1.34 1.53 0.840,s., , 3450 _?1 a x ;' . 345< a,i9 , 2 x 1 Yx x 1 1,49 1.41 1.88 1.50 ' 11/2x 114x44 S00 1A5 ' 1.45 1.62 0.92 5tx40x15 3450 -7.3.;192552 ,:j 32x32x2i1 345, � ' 0a` 2x11rx1't 500 1.6 1. -'1 1.62 1)44114x1 500 1.56 1.59 1.67 0.95 x40x?' 2xliirix 1 500 1.73 1.65 2.02 ' 1.64 1 <x 1 x 1 500 1.88 1.8$ 1.62 1,45 6 :45.'1 "2i2x1 .x l':{ 500 1.90 1.82 2.10 1.80 lir+,1';a x? 500 2.10 2.10 ' 1.90 1,75 ;,ra5n '162 ;s 34 2 x 1..;liiii 500 2.02 1.94 2.16 2.00 1 x14 5001.41 1,34 1.66 0.95 �,; 3 ,9 44 y,. : 34041 43 2 x 1!ix 2 500 2.25 2.16 2,25 2.35 1. 1 x=t 500 1 .52 1.37 1.75 1.14 7, _,>�, a;SG ani ;°" 0.52 2 x 2; 500 1.49 1.49 1,88 1.60 1 :x x 1 sob t.6s i.50 1.80 1.17 3.150 ./ 5 73 2 x 2 x>y 500 1.60 1.60 1.97 1,68 1:':x 1 x 1/1 S00 1.82 1.67 1.68 1.34 3Cr5;. .C. 4att7 .�c� 4'dd 42 42 2 x 2 x 1 500 173 173 2.02 - 1.85 114 x l x 1/1. 500 1.94 L80 1-94 1.45 `"' 2x2 x1,4 500 1.90 1.90 2.10 2.04 1'l xl s4 x 1h 500 1.41 1.34 1 1.66 1,05 , 32 40 x 3'15 200'4 - 500 2.02 2.02 2.16 2.16 115x1Ya14 500 1.52 1.45 1.75 1.15 42.42 4445 40 z.32 r 70 , ,.r r x 2 x 2:'r 500 2.60 2,60 239 3.61 114%1%1(1 500 1.65 1.58 1.60 1:25 0 4x4 X?5 ,; ; t • . x 2 x ; 500 1 79 1.60 2.32 2.28 11hx1Y{x2 500 2,16 2.10 7.02 1.90 ,. °? 40x32x5C' 5;i' 54.x- n- _ 141 x 114x45 500 1.41 1.41 116' 1.15 it.-w P, s,we Ratings ore for retrrr roc only Qn<l based an Soh .iQ pip.,for it�c 49 x 4ii 1 15 345,,E 35.8; orad yrxrc local Mva_l Repreientatroti s.mesas pi*c xhedulc,please visit tocol Oil.com or 22U - Mechanical Joint C110/A21 .10 TYLER UNION' Full Body Revised 10/09 Quality Waterworks Products SUBMITTAL (Current Revisions for All Standards Apply) SIZES: 2" through 48" STANDARDS: ANSI/AWWA Cl 10/A21.10-08 and 3"-12" UL Listed (EX21 1 1) Note: Cast with tested and traceable ASTM A536 Ductile Iron PRESSURE RATING: 2"- 24" rated @ 350 PSI; 30"- 48" & all fittings with flanged branches rated @ 250 psi Note: With use of special flange gasket 2"-24" flanged fittings can be rated @ 350 psi DEFLECTION: Upon completion of installation, mechanical joint fittings 2" - 12" are rated for a maximum of 5° deflection and 14" - 48", a maximum of 3° deflection. NSF-61: Meets all requirements, UL Registered BITUMINOUS M- B - COATING• ANSI/AWWA C104/A21.4-08 L CEMENT LINING: ANSI/AWWA C104.A21.4-08, 0.19 -{ y o Double cement lining available \\b \\\ EPDXY COATING• ANSI/AWWA C116/A21.16-09 �- 1 ,'- X g Note: Epoxy coated fittings are \\\\ KW% � available to the specification(s) �\��Oy •��\\\\ required for your application(s) Ar Ar.r 7 BARE• Available F-P 0.12 BOLTS: ANSI/AWWA C111/A21.11-7 K2 J D C A N F K1 INSTALLATION: AWWA C600-99 using pipe conforming to ANSI/AWWA C151/A21.51-02 JOINT DIMENSIONS IN INCHES Size A B C D F 0 X J K' K2 L M NOP S 2 2.50 2.50 3.39 3.50 2.61 28° 3/4 4.75 6.25 6.25 .75 .62 .31 .63 .44 3 3.96 2.50 4.84 4.94 4.06 28° 3/4 6.19 7.69 7.69 .94 .62 1.37 .31 .63 .52 4 4.80 2.50 5.92 6.02 4.90 28° '/8 7.50 9.12 9.12 1.00 .75 1.50 .31 .75 .65 6 6.90 2.50 8.02 8.12 7.00 28° 78 9.50 11.12 11.12 1.06 .88 1.63 .31 .75 .70 8 9.05 2.50 10.17 10.27 9.15 28° '/8 11.75 13.37 13.37 1.12 1.00 1.75 .31 .75 .75 10 11.10 2.50 12.22 12.34 11.20 28° '/8 14.00 15.69 15.62 1.19 1.00 1.75 .31 .75 .80 12 13.20 2.50 14.32 14.44 13.30 28° /8 16.25 17.94 17.88 1.25 1.00 1.75 .31 .75 .85 14 15.30 3.50 16.40 16.54 15.44 28° %8 18.75 20.31 20.25 1.31 1.25 2.00 .31 .75 .89 16 17.40 3.50 18.50 18.64 17.54 28° /8 21.00 22.56 22.50 1.38 1.31 2.06 .31 .75 .97 18 19.50 3.50 20.60 20.74 19.64 28° '/8 23.25 24.83 24.75 1.44 1.38 2.13 .31 .75 1.05 20 21.60 3.50 22.70 22.84 21.74 28° 7/8 25.50 27.08 27.00 1.50 1.44 2.19 .31 .75 1.12 24 25.80 3.50 26.90 27.04 25.94 28° '/8 30.00 31.58 31.50 1.62 1.56 2.31 .31 .75 1.22 30 32.00 4.00 33.29 33.46 32.17 20° 1Y8 36.88 39.12 39.12 1.81 2.00 2.75 .38 1.00 1.50 36 38.30 4.00 39.59 39.76 38.47 20° 1%8 43.75 46.00 46.80 2.00 2.00 2.75 .38 1.00 1.80 42 44.50 4.00 45.79 45.96 44.67 20° 1% 50.62 53.12 53.12 2.00 2.00 2.75 .38 1.00 1.95 48 50.80 4.00 52.09 52.26 50.97 20° 13/8 57.50 60.00 60.00 2.00 2.00 2.75 .38 1.00 2.20 Tyler Pipe Company • 11910 CR 492 • Tyler, Texas 75706 • (800) 527-8478 Union Foundry Company • 1501 W. 17th Street • Anniston,Alabama 36202 • (800) 226-7601 www.tylerunion.com DUCTILE IRON C110 FULL BODY MECHANICAL JOINT DIMENSIONS TYLER UNION® SAMPLE SPECIFICATION Mechanical Joint watermain fittings with accessories, 2"through 48"shall be produced of Ductile Iron in accordance with and meet all applicable terms and provisions of standards ANSI/AWWA Cl 10/A21.10 ANSI/AWWA C111/A21.11 (current revi- sions). Ductile Iron Mechanical Joint Fittings 3"through 24"shall be rated for 350 PSI working pressure. All Ductile Iron Me- chanical Joint Fittings 30"through 48"shall be rated for 250 PSI working pressure. Flanged ductile-iron fittings in 24-in. (610 mm) and smaller sizes may be rated for 350 psi (2,413 kPa) with the use of special gaskets. NOTE - EXCEPTIONS: Mechanical Joint Fittings with flanged branches and 14" and larger caps and plugs are rated for water pressure of 250 PSI. NOTE: Fittings are CEMENT-LINED and seal coated in accordance with ANSI/AWWA C104/A21.4; also available double cement-lined, bare or epoxy coated.All coated fittings meet requirements of NSF-61. JOINT DIMENSIONS IN INCHES FOR MECHANICAL JOINT FITTINGS DIMENSIONS IN INCHES Size A B C D F 1/3 X J K' K2 L M N 0 P S *2 2.50 2.50 3.39 3.50 2.61 28° 3/4 4.75 6.25 6.25 .75 .62 ... .31 .63 .44 3 3.96 2.50 4.84 4.94 4.06 28° 3/4 6.19 7.69 7.69 .94 .62 1.37 .31 .63 .52 4 4.80 2.50 5.92 6.02 4.90 28° '/8 7.50 9.12 9.12 1.00 .75 1.50 .31 .75 .65 6 6.90 2.50 8.02 8.12 7.00 28° 7/8 9.50 11.12 11.12 1.06 .88 1.63 .31 .75 .70 8 9.05 2.50 10.17 10.27 9.15 28° '/e 11.75 13.37 13.37 1.12 1.00 1.75 .31 .75 .75 10 11.10 2.50 12.22 12.34 11.20 28° '/8 14.00 15.69 15.62 1.19 1.00 1.75 .31 .75 .80 12 13.20 2.50 14.32 14.44 13.30 28° 78 16.25 17.94 17.88 1.25 1.00 1.75 .31 .75 .85 14 15.30 3.50 16.40 16.54 15.44 28° '/8 18.75 20.31 20.25 1.31 1.25 2.00 .31 .75 .89 16 17.40 3.50 18.50 18.64 17.54 28° 78 21.00 22.56 22.50 1.38 1.31 2.06 .31 .75 .97 18 19.50 3.50 20.60 20.74 19.64 28° Ye 23.25 24.83 24.75 1.44 1.38 2.13 .31 .75 1.05 20 21.60 3.50 22.70 22.84 21.74 28° '/8 25.50 27.08 27.00 1.50 1.44 2.19 .31 .75 1.12 24 25.80 3.50 26.90 27.04 25.94 28° '/8 30.00 31.58 31.50 1.62 1.56 2.31 .31 .75 1.22 30 32.00 4.00 33.29 33.46 32.17 20° 1'/8 36.88 39.12 39.12 1.81 2.00 2.75 .38 1.00 1.50 36 38.30 4.00 39.59 39.76 38.47 20° 1 Y8 43.75 46.00 46.00 2.00 2.00 2.75 .38 1.00 1.80 42 44.50 4.00 45.79 45.96 44.67 20° 13/s 50.62 53.12 53.12 2.00 2.00 2.75 .38 1.00 1.95 48 50.80 4.00 52.09 52.26 50.97 20° 13/8 57.50 60.00 60.00 2.00 2.00 2.75 .38 1.00 2.20 *Not included in AWWA C110. ACCESSORIES AND WEIGHTS 14"THRU 48" GLANDS MAY Wt. of Gland, Pipe BE TAPERED Bolt Bolt Bolt Torque Bolts and Barrel Size No. Size Length Ft/Lbs. Gasket,Lbs. O.D. *2 2 5/8 3 45-60 5 2.50 M F - B 3 4 % 3 45-60 7 3.96 - L 4 4 3/4 3'/2 75-90 10 4.80 - 0 6 6 3/4 4 75-90 16 6.90 0.19 8 6 3/4 4 75-90 25 9.05 10 8 3/4 4 75-90 30 11.10 7f f j 12 8 3/4 4 75-90 40 13.20 .� 14 10 3/4 4'/2 75-90 45 15.30 -, -, \N WM \ 16 12 3/4 41/2 75-90 55 17.40 k\�\\� 0 2• 18 12 3/4 4'/2 75-90 65 19.50 Ar A7,1r 0 \\� 20 14 3/4 4'/2 75-90 85 21.60 ,, 24 16 3/4 5 75-90 105 25.80 ~P 30 20 1 6 100-120 220 32.00 0.12 36 24 1 6 100-120 301 38.30 K2 J D C A N y F K1 42 28 11/4 61/2 120-150 389 44.50 48 32 11/4 61/2 120-150 477 50.80 * Not included in AWWA C110. ANSI/AWWA C110/A21.10,ANSI/AWWA C111/A21.11 Tyler Utilities Division • 11910 CR 492 • Tyler,Texas 75706 • (800)527-8478 02/01/08 Union Foundry Company • Box 309 • Anniston,Alabama 36202 • (800) 226-7601 11 DUCTILE IRON C110 FULL BODY MECHANICAL JOINT FITTINGS TYLER UNION® fy At -.A aroIk1r,s1 C k or 3360 M1, MJ x FIPT ECCENTRIC REDUCER Dimensions Size L Weights 6x2 13 51 8x2 15 71 BENDS 90° Bends (1/4) Dimensions Weights p'¢lki ip" 1Om=%p" Size R Y Z MJxMJ MJxPE MJxFE *2 2.25 3.25 16 Y R ' R- ._ ARigi Y 's• , 3 4.0 5.5 13.5 26 36 nil ',5 4 4.5 6.5 14.5 56 53 51 ..`'�I'�•-iI% ...l• •.I 8.0 16.0 88 80 ��• 8 7.0 9.0 17.0 123 119 118 Y " Y --- 10 9.0 11.0 19.0 189 181 168 90°MJ x MJ (1/4) 90°MJ x FE (1/4) 12 10.0 12.0 20.0 268 252 288 14 11.5 14.0 22.0 380 ... ... 16 12.5 15.0 23.0 552 470 465 'M'�,��ie"' 18 14.0 16.5 24.5 625 600 577 920 15.5 18.0 26.0 862 775 ... % R 24 18.5 22.0 30.0 1423 1301 1150 Y I 'y 11< .... 30 21.5 25.0 33.0 1942 1920 ... 90°MJ x PE (1/4) �•`yhy - 36 24.5 28.0 36.0 2629 2310 I 42 27.5 31.0 3410 ... ... Z ^ 48 30.5 34.0 4595 ... ... Mechanical Joint weights do not include Glands, For sizes not found in this section check MJ-SSB DI Nuts, Bolts and Gaskets. fittings, pages 1 thru 8. See Joint Accessories. ANSI/AWWA C110/A21.10,ANSI/AWWA C111/A21.11 Tyler Utilities Division • 11910 CR 492 • Tyler,Texas 75706 • (800) 527-8478 12 Union Foundry Company• Box 309 • Anniston,Alabama 36202 • (800)226-7601 02/01/08 ., DUCTILE IRON C110 FULL BODY MECHANICAL JOINT FITTINGS TYLER UNION' 45° Bends (1/8) BENDS Dimensions Weights Size RY Z MJ MJxFE* MJxPE v•-:"( Y si *2 1.96 1.8 16 ... si�'ii�''._.....,,ui.,,, 2 3 3.62 3.0 11.0 30 ... ` ' 4.,41,i,,,, - _� 4 4.81 4.0 12.0 53 48 45 , ,/ ti 6 7.25 5.0 13.0 77 60 69 �`,� -1;'-'4411,/ '// R 8 8.44 5.5 13.5 110 107 111 410 10.88 6.5 14.5 172 168 167 45°MJ (1/8) 45°MJ x PE (1/8) 12 13.25 7.5 15.5 222 215 218 14 12.06 7.5 15.5 311 16 13.25 8.0 16.0 364 360 360 ,.-1-1, y 18 14.50 8.5 16.5 531 430 455 :���-- ,, /7 it 20 16.88 9.5 17.5 655 543 664 24 18.12 11.0 19.0 865 1099 825 30 27.75 15.0 23.0 1447 ... 1510 36 35.00 18.0 26.0 2435 ... 1930 R '' 42 42.25 21.0 2955 ... ... 45°MJ x FE (1/8) 48 49.50 24.0 4080 ... ... * Not included in AWWA C110. Y -y. Y 221/2° Bends (1/16) s i-r.' �'.---__i ?."__ ! Dimensions Weights 't; Size R Y Z MJ MJxFE* MJxPE 111# -- ,� ill/ 3 7.56 3.0 11.0 30 •�„�, //'� - 4 10.06 4.0 12.0 52 ... : ; s R 6 15.06 5.0 13.0 77 71 70 221/2°MJ (1/16) 22'/2°MJ x PE (1/16) 8 17.62 5.5 13.5 110 107 109 10 22.62 6.5 14.5 156 155 163 12 27.62 7.5 15.5 221 215 224 r'( Y--7 14 25.12 7.5 15.5 300 ... 16 27.62 8.0 16.0 391 315 365 18 30.19 8.5 16.5 527 422 455 ,*+ 20 35.19 9.5 17.5 611 575 ' 24 37.69 11.0 19.0 986 800 930 liers R 30 57.81 15.0 23.0 1898 ... 1540 221/2 MJ x FE (1/16) 36 72.88 18.0 26.0 2372 ... 1970 42 88.00 21.0 3020 ... ... 48 103.06 24.0 4170 ... ... Y Y 11'/4° Bends (1/32) : ,,,,,,._,,..„_,, = Y Z - Dimensions Weights I',"""'" -- ---------- 01,,,________...._ Size R Y Z MJ MJxFE* MI(PE 3 15.25 3.0 1 1.0 30 /�/�����-���"'�,�I ,• 4 20.31 4.0 12.0 52 R '` r R 6 30.50 5.0 13.0 65 71 11'/4°MJ (1/32) 111/4°MJ x PE (1/32) 8 35.50 5.5 13.5 104 105 ... 10 45.69 6.5 14.5 171 ... ... 12 55.81 7.5 15.5 221 215 ... 14 50.75 7.5 15.5 305 ... ... Y Y-� 16 55.81 8.0 16.0 391 367 ... s i 18 60.94 8.5 16.5 525 422 20 71.06 9.5 17.5 605 ... 24 76.12 11.0 19.0 996 800 972 j/r�-- --..,� 30 116.75 15.0 23.0 1410 ... 1305 : R - 36 147.25 18.0 26.0 2397 ... 2185 111/4°MJ x FE (1/32) 42 177.69 21.0 3035 ... ... 48 208.12 24.0 4190 ... ... ANSI/AWWA C110/A21.10,ANSI/AWWA C111/A21.11 Tyler Utilities Division • 11910 CR 492 • Tyler,Texas 75706 • (800) 527-8478 02/01/08 Union Foundry Company • Box 309 • Anniston,Alabama 36202 • (800)226-7601 13 DUCTILE IRON C110 FULL BODY MECHANICAL JOINT FITTINGS TYLER UNION® MJ TAPPED TEE MJ Tapped Tee (2"Tapj Dimensions L Size L Max.Tap Weights s fillIIII.III .•../._ .i.-.#//ill 3 8 2 40 4 8 2 51 For sizes not found in this 6 8 2 73 section check MJ-SSB DI 8 8 2 104 fittings, pages 1 thru 8. //0�,,.. 10 8 2 130 F 12 8 2 180 TEES Size Dimensions Weights �;p��w. Run Run Branch X Y Z MJ **MJxPExMJ **MJxMJxFE r -% Z* 2 2 2 3.25 3.25 ... 21 r `,,,. ._% `•__ rf , *3 3 2 3.25 3.25 ... 45 ... ... Ii,_' _ __ • II11 ' 3 3 3 5.5 5.5 13.5 58 ... ... } *4 4 2 4.8 4.8 14.5 68 49 x x- 4 4 3 6.5 6.5 14.5 77 ... ... Straight Tees and 4 4 4 6.5 6.5 14.5 78 75 76 Reducing on Branch Tees 4 4 6 8.0 8.0 112 *6 6 2 8.0 8.0 ... 78 ... ... 6 6 3 8.0 8.0 16.0 112 ... ... 6 6 4 8.0 8.0 16.0 110 ... 109 6 6 6 8.0 8.0 16.0 119 120 141 T .,_ y 6 6 8 9.0 9.0 ... 158 ... ... 1 8 8 3 9.0 9.0 17.0 155 Y ""�� j 1i 8 8 4 9.0 9.0 17.0 157 ... 150 1 N 8 8 6 9.0 9.0 17.0 175 170 182 - ' 8 8 8 9.0 9.0 17.0 199 180 194 _-' " • 10 10 4 11.0 11.0 19.0 ... ... 229 x--»--x 10 10 6 11.0 11.0 19.0 258 ... 264 Bullhead 10 10 8 11.0 11.0 19.0 268 ... 245 10 10 10 11.0 11.0 19.0 300 250 ... 12 12 4 12.0 12.0 20.0 318 315 323 12 12 6 12.0 12.0 20.0 325 325 335 1-- :r cmc 12 12 8 12.0 12.0 20.0 335 335 372 L... j �„- 12 12 10 12.0 12.0 20.0 392 390 iii 12 12 12 12.0 12.0 20.0 396 396 476 ����� _.,,,i') *16 16 4 15.0 15.0 600 ... 575 X x 16 16 6 15.0 15.0 ... 656 ... 605 16 16 8 15.0 15.0 ... 625 ... 615 MJxMJxFE 16 16 10 15.0 15.0 ... 645 ... ... 16 16 12 15.0 15.0 ... 715 ... 651 16 16 16 15.0 15.0 ... 780 ... 730 * Not included in AWWA C110 ** Made to order only. Not Returnable NOTICE: Weights published in this catalog are for shipping purposes only. Actual weights may vary because some fittings are produced in both foundries. All fittings meet the AWWA standards to which they are designed. For weights of specific fittings, please contact Tyler Pipe or Union Foundry Company. ANSI/AWWA C110/A21.10,ANSI/AWWA C111/A21.11 Tyler Utilities Division • 11910 CR 492 • Tyler,Texas 75706 • (800)527-8478 14 Union Foundry Company • Box 309 • Anniston,Alabama 36202 • (800)226-7601 02/01/08 y �M DUCTILE IRON C110 FULL BODY MECHANICAL JOINT FITTINGS TYLER UNION® TEES (Con't) Size Dimensions Weights Run Run Branch X Y Z MJ **MJxPExMJ **MJxMJxFE Nf ��M: %:F z --- 18 18 6 13.0 15.5 ... 710 707 F 18 18 8 13.0 15.5 ... 674 ... 675 Y 1-:- ---.,.-" i if 1 18 18 12 13.0 15.5 ... 749 ... 733 11 18 18 18 16.5 16.5 945 953 ���•� --���====7 20 20 6 14.0 17.0 ... 849 ... ii x x- 20 20 8 14.0 17.0 ... 892 859 Straight Tees and 20 20 12 14.0 17.0 896 Reducing on Branch Tees 20 20 16 18.0 18.0 ... 1095 ... 20 20 20 18.0 18.0 ... 1258 ... 1168 24 24 6 15.0 19.0 ... 1233 ... 1228 24 24 8 15.0 19.0 ... 1234 ... 1242 41;��M. 24 24 12 15.0 19.0 ... 1256 ... 1165 I: 1 24 24 14 15.0 19.0 ... 1220 V 24 24 16 15.0 19.0 1245 ... ti",,-„) ..\-----,1" 24 24 18 22.0 22.0 ... 1735 - 24 24 20 22.0 22.0 ... 1720 ... ... i�� y�1 24 24 24 22.0 22.0 ... 1947 1795 x--»-- i�` -- 30 30 6 18.0 23.0 ... 2050 ... ... Bullhead 30 30 8 18.0 23.0 ... 2060 ... ... 30 30 10 18.0 23.0 ... 2075 ... ... 30 30 12 18.0 23.0 ... 2090 .... ... 30 30 16 18.0 23.0 ... 2145 ... �- 'M9'� i - %M% 30 30 18 18.0 23.0 ... 2170 ... ... Y 30 30 20 18.0 23.0 ... 2205 ... ... i ' ' ./ -, ,'p 30 30 24 25.0 25.0 ... 2880 ... I!" - ' 30 30 30 25.0 25.0 ... 2275 3080 36 36 6 20.0 26.0 ... 2439 ... 2430 x -x 36 36 8 20.0 26.0 ... 2444 MJxMJxFE 36 36 10 20.0 26.0 ... 2535 ... ... 36 36 12 20.0 26.0 ... 2541 ... 2550 36 36 14 20.0 26.0 ... 2570 ... ... 36 36 16 20.0 26.0 ... 2585 ... 2450 36 36 18 20.0 26.0 ... 2610 ... ... 36 36 20 20.0 26.0 ... 2635 ... ... 36 36 24 20.0 26.0 ... 2792 ... 2660 36 36 30 28.0 28.0 ... 3545 ... ... 36 36 36 28.0 28.0 ... 3450 ... 42 24 42 23.0 30.0 ... 3690 ... ... 42 30 42 31.0 31.0 ... 4650 ... ... 42 36 42 31.0 31.0 ... 4880 ... ... 42 42 42 31.0 31.0 ... 6320 ... 48 24 48 26.0 34.0 ... 4995 ... ... 48 30 48 26.0 34.0 ... 5140 ... ... 48 36 48 34.0 34.0 ... 6280 ... ... 48 42 48 34.0 34.0 ... 8130 ... ... 48 48 48 34.0 34.0 ... 8420 ... ... *Not included in AWWA C110 **Made to order only. Not Returnable ANSI/AWWA C110/A21.10,ANSI/AWWA C111/A21.11 Tyler Utilities Division • 11910 CR 492 • Tyler,Texas 75706 • (800)527-8478 02/01/08 Union Foundry Company • Box 309 • Anniston,Alabama 36202 • (800)226-7601 15 UCTILE IRON C110 FULL BODY DMECHANICAL JO NT FITTINGS TYLER UNION® WYES/LATERAL CROSSES (Not included in AWWA C110.) n.���N .p.=� N 11..14 jI- hj1 :IY = / !l4iPi! ir+Andr,II/fo *01 • PI Al 1 N�_aimi�•N- -Nv��'N• z - x ALL MJ *MJ xMJxFExFE Size Dimensions Size Dimensions Weights Run Branch X Z Weights Run Branch X Y MJ *MJxFE 3 3 10.0 3.0 60 6 6 8.0 8.0 160 141 4 4 12.0 3.0 90 8 4 9.0 9.0 185 6 4 14.5 3.5 130 8 6 9.0 9.0 205 182 6 6 14.5 3.5 145 8 8 9.0 9.0 255 245 10 6 11.0 11.0 285 8 4 17.5 4.5 190 10 8 11.0 11.0 310 8 6 17.5 4.5 205 10 10 11.0 11.0 380 360 8 8 17.5 4.5 230 12 6 12.0 12.0 361 367 10 6 20.5 5.0 330 12 8 12.0 12.0 371 373 10 8 20.5 5.0 310 12 12 12.0 12.0 486 487 10 10 20.5 5.5 435 14 8 14.0 14.0 550 ... 12 8 24.5 5.5 505 14 14 14.0 14.0 779 ... 12 12 24.5 5.5 490 16 6 15.0 15.0 650 ... 14 6 27.0 6.0 626 16 8 15.0 15.0 675 655 16 16 30.0 6.5 1079 16 16 15.0 15.0 895 875 18 8 32.0 7.0 1073 18 8 13.0 15.5 775 ... 18 10 32.0 7.0 975 18 10 13.0 15.5 760 18 12 32.0 7.0 1015 18 12 13.0 15.5 860 ... 18 16 32.0 7.0 1135 18 18 16.5 16.5 1 140 ... 18 18 32.0 7.0 1130 20 8 14.0 17.0 951 ... 20 10 35.0 8.0 1220 20 12 14.0 17.0 977 ... 20 12 35.0 8.0 1260 20 16 18.0 18.0 1245 ... 20 16 35.0 8.0 1375 20 20 18.0 18.0 1448 ... 20 20 35.0 8.0 1525 24 8 15.0 19.0 1244 ... 24 24 40.5 9.0 2372 24 12 15.0 19.0 1326 ... 30 30 49.0 10.0 3670 24 16 15.0 19.0 1479 ... 24 20 22.0 22.0 1965 ... 24 24 22.0 22.0 2192 ... 30 6 18.0 23.0 2085 ... 30 12 18.0 23.0 2165 ... For sizes not found in this 30 24 25.0 25.0 3180 section check MJ-SSB DI 30 30 25.0 25.0 3640 fittings, pages 1 thru 8. 36 36 28.0 28.0 4370 ... * Not included in AWWA C110. ANSI/AWWA Cl 10/A21.10,ANSI/AWWA C111/A21.11 Tyler Utilities Division • 11910 CR 492 • Tyler,Texas 75706 • (800)527-8478 16 Union Foundry Company • Box 309 • Anniston,Alabama 36202 • (800) 226-7601 02/01/08 DUCTILE IRON C110 FULL BODY MECHANICAL JOINT FITTINGS TYLER UNION® REDUCERS Laying Lengths(L) Weights L Size MJ MJ-SEB MJ-LEB PExPE FExMJ MJxFE MJ MJ-SEB MJ-LEB PExPE FExMJ MJxFE _,,,, ". * 3x2 6 14 1424 24 24 �/ *4x2 7 15 15 ... ... ... 31 30 31 ... ... ... III1111''i" i'1 lvii 4x3 7 15 15 23 7 7 37 38 37 34 34 35 I ', • �,') *6x2 9 17 17 ... ... ... 46 43 47 �p�/""' v"''= 6x3 9 17 17 ... ... 9 55 50 55 ... ... 50 6x4 9 17 17 25 9 9 56 60 59 57 53 62 MJ Reducer 8x3 11 19 19 ... ... 84 77 70 ... L 8x4 11 19 19 ... 11 11 84 82 84 ... 73 75 8x6 11 19 19 27 11 11 94 90 93 96 84 80 ii,/� 10x6 12 20 20 ... 12 12 115 116 117 ... 100 105 """",,,I 10x8 12 20 20 28 12 12 142 135 130 135 130 130 12x4 14 22 22 ... ... ... 139 131 „ ,II 12x6 14 22 22 ... 14 12 148 150 153 ... 145 130 ' 4s e..,„ a 12x8 14 22 22 30 14 12 173 168 165 168 170 175 MJ Small End Bell Reducer 12x10 14 22 22 30 14 12 194 190 178 185 188 190 14x6 16 195 L y 14x8 ... ... ... ... ... � I ... 16 ... ... ... ... 215 '�.�., 14x12 270 '" 16x6 18 250 16x8 18 26 ... ... ... ... 288 248 ... ... ... ... IIII' 16x10 18 300 -- """"""" 16x12 18 26 26 ... 18 18 330 304 325 ... 305 325 ? 16x14 18 370 MJ Large End Bell Reducer 18x8 19 ... ... ... ... 19 320 ... ... ... ... 300 18x10 19 388 I L y 18x12 19 27 ... ... ... 19 380 355 ... ... ... 405 18x14 19 450 18x16 19 ... ... ... ... 19 476 ... ... ... ... 445 20x10 20 410 20x12 20 28 ... ... ... ... 515 420 ... ... ... ... 20x16 20 28 28 20 578 525 510 510 #,,, #/#"." 20x18 20 575 Plain End-Plain End Reducer 24x12 24 32 24 610 570 455 24x16 24 32 32 ... ... ... 705 665 753 ... ... ... 24x18 24 32 ... ... ... 789 720 ... ... ... ... L 24x20 24 32 32 ... ... ... 815 775 804 ... ... ... ;" " a- *30x16 30 38 ... 46 ... ... 1 150 1040 ... 1015 ... ... "�// 30x18 30 38 ... 46 ... 1160 1050 ... 1025 30x20 30 38 ... 46 ... 1225 1120 ... 1090 ... ... 30x24 30 38 38 46 ... ... 1360 1255 1320 1215 ... ... ",.07'" 36x20 36 ... 44 ... 1495 ... 1466 36x24 36 ... 44 52 ... ... 1580 ... 1535 1389 ... FExMJ Reducer 36x30 36 44 ... 52 ... ... 1919 1721 ... 1585 ... ... L 42x24 42 2060 42x30 42 2370 42x36 42 ... ... ... ... ... 2695 ... 48x30 48 ... ... ... ... ... 3005 ... 48x36 48 ... ... ... ... ... 3370 ... 48x42 48 ... ... ... ... ... 3750 ... * Not included in AWWA Cl 10 MJxFE Reducer ANSI/AWWA C110/A21.10,ANSI/AWWA C111/A21.11 Tyler Utilities Division • 11910 CR 492 • Tyler,Texas 75706 • (800)527-8478 02/01/08 Union Foundry Company• Box 309 • Anniston,Alabama 36202 • (800) 226-7601 17 DUCTILE IRON C110 FULL BODY MECHANICAL JOINT FITTINGS TYLER UNION® SOLID SLEEVES 1 L Si 6.6 elf n#n/1/IIFQFFFFFn/1 ' yr,,,,,,,....~IPM-a..." . i 11 1 i geh.ite/0.W.1w{iriFi rplj $ eItefo neWIREsRe'frinfiFk% ii Standard � * Dual Purpose t Pipe Short Long Pipe Short Long Size O.D. L Weight L Weight Size O.D. L Weight L Weight *2 2.50 8.0 13 12 18 4 4.80/5.00 7.5 33 12 44 3 3.96 7.5 ... 12 36 6 6.90/7.10 7.5 46 12 63 4 4.80 7.5 35 12 47 8 9.05/9.30 7.5 65 12 88 • 6 6.90 7.5 45 12 65 10 11.10/11.40 ... ... 12 111 8 9.05 7.5 65 12 90 t12 13.20/13.50 ... ... 12 221 10 11.10 7.5 85 12 115 t16 17.40/17.80 ... ... 15 385 12 13.20 7.5 120 12 136 All Sizes Use MJ Dual Purpose Gland 16 17.40 9.5 206 15 281 * Not included in AWWA C110 18 19.50 9.5 246 15 362 t 12"& 16"are sold assembled NOTE: Sizes 4-10"use standard MJ Gaskets; 20 21.60 9.5 275 15 404 12"and 16"require special duo gaskets. 24 25.80 9.5 360 15 540 30 32.00 15.0 745 24 1085 36 38.30 15.0 1047 24 1502 42 44.50 ... ... 24 1550 48 50.8 ... ... 24 1940 * Not included in AWWA C110 * MJ x PE DUAL-PURPOSE CUTTING-IN SLEEVE With Dual-Purpose Accessories (NOTES: Gland with cup-joint set screws available at extra cost ADAPTERS when specified. NOT FOR RESTRAINT.) Currently, Tyler and Union Dual Purpose Glands are NOT MJ x FE L interchangeable. Dimensions Size L Weights 3 8 30 S Cutting-In t- MIlMl 4 8 42 Sleeve&Gland DC 6 8 62 L. ... .11 8 8 88 I 10 8 120 L---L L. ----L---L 12 8 150 Weight 16 8 257 For Use Gland Gland 18 8 324 Size On Pipe O.D. L L' D Only &Sleeve 20 8 365 4 4.80 - 5.00 12 8 4.80 6.0 72 24 8 528 6 6.90 - 7.10 12 8 6.90 10.0 94 30 10 760 8 9.05 - 9.30 12 8 9.05 16.0 122 36 10 1070 10 1 1.10 - 1 1.40 12 8 11.10 25.0 175 12 13.20 - 13.50 12 8 13.20 30.0 235 * Not included in AWWA C110. ANSI/AWWA C110/A21.10,ANSI/AWWA C111/A21.11 Tyler Utilities Division • 11910 CR 492 • Tyler,Texas 75706 • (800)527-8478 18 Union Foundry Company• Box 309 • Anniston,Alabama 36202 • (800) 226-7601 02/01/08 lDUCTILE IRON C110 FULL BODY MECHANICAL JOINT FITTINGS TYLER UNION® PLUGS CAPS OFFSETS L - -, 1;411 < flip ti ''• ,., N ISI '''�►.�r-� i" Solid or Tapped '"��``•y r'IIlt-11 i :., Weight ''`•..,II =� Solid or Tapped Size Tap Solid Tapped Weight *2 2 6 ... MJxMJ MJxPE Size Tap Solid Tapped 3 2 10 10 Dimensions Weights *2 2 5 5 4 2 18 13 Size D L' L MJxMJ MJxPE 3 2 9 9 6 2 34 30 4 6 19 27 ... 82 4 2 13 14 8 2 46 45 4 12 22 30 85 80 6 2 15 15 10 2 58 54 4 18 30 38 105 ... 8 2 45 45 12 2 86 80 * 4 24 26 34 126 125 10 2 66 66 16 2 178 175 6 6 20 28 114 105 12 2 79 79 t18 2 215 215 6 12 26 34 148 143 t20 2 250 249 6 18 33 41 188 176 14 2 120 120 * 6 24 24 32 182 160 16 2 147 147 t24 2 370 370 -I-18 2 192 190 t30 2 680 680 8 6 21 29 177 155 t36 2 850 850 8 12 28 36 231 195 t20 2 220 219 42 1180 8 18 35 43 287 282 t "' 24 2 338 338 * 8 24 36 44 280 285 t30 2 660 660 48 1595 ... 10 12 30 38 347 280 T36 2 838 838 tDished-Not flat as shown. 10 18 38 46 340 340 42 .. 1 180 ... * Not included in 10 24 38 46 420 ... 48 .. 1455 ... AWWA C110. 12 12 37 45 420 420 12 18 48 56 520 520 t Dished-Not flat as shown. *12 24 48 56 649 630 * Not included in AWWA C110. 16 12 40 48 715 16 18 50 58 850 830 *20 12 40 48 1025 ... `�� II��`� ? *20 18 48 60 1362 ... y.,�\ raH-- �/11111)! * Not included in AWWA C110. - ii.., i31:1 e31� ` 4-- � IJI/!11 \\ N.,1L :::::)4-0- TYTON® Plug** Solid Tapped Solid or Tapped Push-In Plug with Ears Size Tap T Weight* (To be used with all push-in 4 2 .60 18 pipe and fittings) 6 2 .65 25 Size Tap Weight 8 2 .70 46 14 2.0 101 10 2 .75 70 16 2.0 137 12 2 .75 95 18 2.0 177 t20 2.0 239 * Weights do not include accessories t24 2.0 311 **Not included in AWWA C110. MON®is a registured trademark t Dished - Not flat as shown of U.S. Pipe and Foundry Company. NOTE: Blocking still required- ears for assembly only. ANSI/AWWA C110/A21.10,ANSI/AWWA C111/A21.11 Tyler Utilities Division • 11910 CR 492 • Tyler,Texas 75706 • (800)527-8478 02/01/08 Union Foundry Company • Box 309 • Anniston,Alabama 36202 • (800)226-7601 19 DUCTILE IRON C110 FULL BODY MECHANICAL JOINT ELLS, ADAPTERSAT AND GLANDS TYLER UNION' For Valve and Hydrant Connections ADAPTERS Swivel x Solid Adapter VARIABLE Size by Wall Other Swivel Hydrant Laying Length Thickness Weight* Fittings, Pages 3, 4 and 5. 't","I' 4x13 .52 52 6x12 .55 84 6x18 .55 91 6x24 .55 105 6x36 .55 156 8x13 .60 126 12x13 .75 186 *Weights with Gland. ELLS r-. B CE j —_ a *90°Swivel x Swivel Ell D II 1 F (Not Included In AWWA C110) Wall Dimensions A i R - Size Thickness A B C D E F R *Weight 111111MWEIM4IN 6 .55 10.5 15.5 7.10 11.12 6.90 8.02 6.0 106 L i . 8 .60 11.5 16.5 9.20 13.37 9.05 10.17 7.0 156 4111 *With 2 Swivel Glands SWIVEL GLAND ASSEMBLY Used with swivel fittings,the TYLER Swivel Gland,with its rotating feature, permits the installer to meet any grade require- ments regardless of bolt-hole alignment. In addition,the system permits stiff connections without braces, blocking or strapping. Swivel Glands** O +5-`tee ' Size Weight NOTE: When ordering glands O O 12 30 -� ** Not included in separately, AWWA C1 10. (1) Specify TYLER UPCode �� ;� Number, 0 0 (2) Description, and O • , _ , (3) Size of fitting to be joined. ANSI/AWWA C110/A21.10,ANSI/AWWA C111/A21.11 Tyler Utilities Division • 11910 CR 492 • Tyler,Texas 75706 • (800) 527-8478 02/01/08 Union Foundry Company • Box 309 • Anniston,Alabama 36202 • (800) 226-7601 21 IPS CARBON STEEL PIPE—FIRE PROTECTION PRODUCTS 10.03 FireLock® Fittings 0 K> ® ,LPCB VdS See Victaulic publication 10.01 for details FireLock®products comprise a unique system specifically designed for fire protection services.FireLock full-flow elbows and tees are a CAD-developed, hydrodynamic design that has a shorter center-to-end dimension than standard fittings.A noticeable bulge allows the water to make a smoother turn to maintain similar flow characteristics as standard full flow fittings. FireLock fittings are designed for use exclusively with Style 005 and Style 009 FireLock couplings.Use of other couplings or flange adapters may result in bolt pad interference. Victaulic FireLock fittings pressure ratings conform to the ratings of Victaulic FireLock Style 005 couplings. MATERIAL SPECIFICATIONS Fitting: Ductile iron conforming to ASTM A-536,grade 65-45-12. Fitting Coating:Orange enamel. • Optional: Hot dipped galvanized. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.®2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. I Ct'a U I I C REV_H IPS CARBON STEEL PIPE-FIRE PROTECTION PRODUCTS 10.03" FireLock® Fittings DIMENSIONS �CtoEi 'toE� -a I tr- 0 CtoE toEJ" 0 ry..... 0 --ltif); o =1,=,IE NO.001 NO.003 NO.002 NO.006 No.001 No.003 No.002 No.006 Size 90 Elboo. 45 Elbow Stra'ght Tee Cap • Nominal Actual Approx. Approx. Approx. Approx. Size Outside Diameter C to E Weight Each C to E Weight Each C to E Weight Each Thickness"T" Weight Each Inches Inches Inches Lbs. Inches Lbs. Inches Lbs. Inches Lbs. mm mm mm kg mm kg mm kg mm kg 11/4 1.660 _ 0.8 0.3 32 42.4 21 0.1 1 Y 1.900 - - - - - - 0.82 0.4 40 48.3 - - - - 21 0.2 2 2.375 2.75 1.7 2.00 1.8 2.75 2.4 0.88 0.6 50 60.3 70 0.8 51 0.8 70 1.1 22 0.3 21/2 2.875 3.00 3.1 2.25 2.2 3.00 3.6 0.88 1.0 65 73.0 76 1.4 57 1.0 76 1.6 22 0.5 76.1 mm 3.000 3.00 3.30 2.25 2.4 - - 76.1 76 1.5 57 1.1 3 3.500 3.38 4.0 2.50 3.1 3.38 5.3 0.88 1.2 80 88.9 86 1.8 64 14 86 2.4 22 0.5 08mm 4.250 4.00 5.7 3.00 5.1 4.00 7.51 - 108.0 102 • 2.6 76 2.3 102 3.4 4 4.500 4.00 6.7 3.00 5.6 4.00 8.7 1.00 2.4 100 114.3 102 3.0 76 2.5 102 3.9 25 1.1 5 5.563 4.88 12.6 3.25 8.3 1 4.88 15.7 1.00 4.1 125 141.3 124 5.7 83 3.8 124 7.1 25 1.9 159mm 6.250 5.50 12.6 3.50 9.2 5.50 17.9 - 158.8 140 5.7 89 4.2 140 8.0 6 6.625 5.50 18.3 3.50 11.7 5.50 22.7 1.00 5.9 150 168.3 140 8.3 89 5.3 140 10.3 25 2.7 8 8.625 6.81 25.5 4.25 20.4 6.94 38.7 1.13 12.7 200 219.1 173 11.6 108 9.3 176 17.6 29 5.8 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ICt.'a1 iC 10.03_2 REV H IPS CARBON STEEL PIPE-FIRE PROTECTION PRODUCTS 10.03 FireLock® Fittings FLOW DATA Frictional Resistance 5.�.:. Equivalent Feetlineters of Straight Pipe t Actual No.002 Nominal Outside Elbows Straight Tee Size Diameter Inches Inches No.001 1No.003 mm I mm 90°Elbow 45°Elbow Branch Run 1 1/4 1.660 1.5 0.8 3.7 1.5 32 42.4 0.5 0.2 1.1 0.5 1 1/2 1.900 2.2 1.1 5.5 2.2 40 48.3 0.7 0.3 1.7 0.7 2 2.375 I 3.5 1.8 r 8.5 3.5 50 60.3 1.1 0.5 2.6 1.1 2/2 2.875 4.3 2.2 10.8 4.3 65 73.0 1.3 0.7 3.3 1.3 76.1 mm 3.000 4.5 2.3 11.0 4.5 76.1 1.4 0.7 3.4 1.4 3 3.500 5.0 2.6 13.0 5.0 80 88.9 1.5 0.8 4.0 15 O8mm 4.250 6.4 3.2 15.3 6.4 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 3.4 16.0 68 100 114.3 2.1 1.0 4.9 2.1 5 5.563 8.5 4.2 21.0 8.5 125 141.3 2.6 1.3 6.4 2.6 159mm 6.250 9.4 4.9 25.0 9.6 158.8 2.9 1.5 7.6 2.9 6 6.625 10.0 5.0 25.0 10.0 150 168.3 3.0 1.5 7.6 3.0 8 8.625 13.0 5.0 33.0 13.0 200 219.1 4.0 1.5 10.1 4.0 t The flow data listed is based upon the pressure drop of Schedule 40 pipe. • www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ICY.aUIIC` REV_H 10.03_3 IPS CARBON STEEL PIPE- FIRE PROTECTION PRODUCTS 10.03 FireLock® Fittings GENERAL NOTES NOTE:When assembling FireLock EZ couplings onto end caps,take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009 and Style 009V couplings,use FireLock No.006 end caps containing the"EZ"marking on the inside face or No.60 end caps containing the"QV EZ"marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V couplings. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. • 111111111111111111111111111111 WCAS-7MX2JY For complete contact information,visit www.victaulic.com 10.03 1539REV H UPDATED 1/2009 •CtaIUI.C` VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 10.03 Victaulic® FirelockTM Rigid Coupling ✓ctaulic° Style 009N 10.64 . , . ;,,: 1'7r Patented 1.0 CERTIFICATION/LISTINGS C • ® LPCB VdS LIM C104-1a/36 2.0 PRODUCT DESCRIPTION • The FireLock EZTM Style 009N Installation-ReadyTM Rigid Coupling is for use in the fire protection market. • The coupling's unique design eliminates loose parts, promotes consistent installation and provides substantial gains in productivity. • IMPORTANT: FireLock EZTM Style 009N couplings are recommended for use ONLY on fire protection systems. 3.0 MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A 536, Grade 65-45-12. Ductile iron conforming to ASTM A 395, Grade 65-45-15, is available upon special request. Housing Coating: (specify choice) ❑ Orange enamel (North America, Asia Pacific) ❑ Red enamel (Europe) ❑ Hot dipped galvanized Gasket: (specify choice') [j Grade "E" EPDM (Type A) FireLock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited, and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services within the rated working pressure. 1 Services listed are General Service Guidelines only.It should be noted that there are services for which these gaskets are not compatible.Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts: Zinc electroplated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A 449 and physical requirements of ASTM A 183. • System No. Location Spec Section Paragraph Submitted By Date Approved Date • victaulic.com I Couplings I FireLock I Rigid I Style 009N I Publication 10.64 victaulic.com I Couplings I FireLock I Rigid I Style 009N I Publication 10.64 • • 4.0 LISTINGS/APPROVAL 2 The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Nominal Size cULus FM Vds LPCB Sch.5 Sch. 10 Sch.40 Sch.5 Sch. 10 Sch.40 inches psi psi psi psi psi psi psi psi mm kPa kPa kPa kPa kPa kPa kPa kPa 11/4 232 365 365 175 363 363 363 363 32 1600 2517 2517 1205 2502 2502 2500 2500 1' 232 365 365 175 363 363 363 363 40 1600 2517 2517 1205 2502 2502 2500 2500 2 363 365 365 175 363 363 363 363 50 2502 2517 2517 1205 2502 2502 2500 2500 21N/A 365 365 175 363 363 363 363 65 2517 2517 1205 2502 2502 2500 2500 a 76.1 mm N/A 3653 N/A N/A 3634 N/A 363 363 25173 25024 2500 2500 3N/A 365 365 175 363 363 363 363 80 2517 2517 1205 2502 2502 J 2500 2500 4 365 365 175 363 363 363 363 100 N/A 2517 2517 1205 2502 2502 2500 2500 175 363 363 108.0 mm N/A N/A N/A 1205 2502 2502 N/A N/A 5N/A 290 365 N/A 363 363 232 N/A 125 2000 2517 2502 2502 1600 133.0 mm N/A N/A N/A N/A 250244 N/A N/A N/A 139.7mm N/A ?055 N/A N/A 2502290 36344 N/A 12600 N/A 159.0 mm N/A N/A N/A N/A 2502 4 N/A N/A N/A 165.1 mm N/A 2 90 6 N/A N/A 250 44 N/A N/A N/A 000 6N/A 290 365 N/A 363 363 232 N/A 150 2000 2517 2502 2502 1600 216.0 mm N/A N/A N/A N/A 250 63 4 N/A N/A N/A 8 290 365 363 . 363 232 200 N/A 2000 2517 N/A 2502 2502 1600 N/A 2 Listed/Approved for wet and dry pipe systems(>—40°F/-40°C)for continuous use in freezing conditions,use of Style 005H Coupling with Silicone Gasket is recommended. Please see the Victaulic Installation Manual 1-009N/009H for details concerning when supplemental lubrication is required. 3 cULus listed for DIN 2458 2.6 mm pipe wall. 4 FM approved for BS 1387 Medium 3.6 mm pipe wall. 5 cULus listed for EN 10220 4.0 mm pipe wall. 6 cULus listed for EN 10255 4.5 mm pipe wall. • • 10.64 7072 Rev G Updated 10/2014 0 2014 Victaulic Company.All rights reserved. DUCTILE IRON C110 FULL BODY MECHANICAL JOINT FITTINGS TYLER UNION® Pipe Wall Thickness: *RETAINER GLAND ASSEMBLY Sizes 3"-12"are recommended for ductile iron pipe class 50 thru 56. Sizes 14"thru inMit 24" are recommended for ductile iron pipe "'$ r'"" class 53 thru 56. ..2. -4--- Na DUCTILE IRON RETAINER B e \ GLANDS =` �� ������������� Mechanical Joint Retainer Glands are designed to provide a method for restrain- A ing mechanical joint pipe and fittings See Installations Instructions Page 50 and other standardized mechanical joints against possible joint separation, rupture Pressure Gland Pipe O.D. D.I. Pipe No of Size of or blow-out caused by internal water pres- Rating, O.D. O.D. Wall Set Set Gland Weight sure. Size psi B A Class Screws Screws Weight w/Acces. The set screws are square-headed 3 350 7.69 3.96 50-56 4 5/8x2 4 8 with Type C knurled cup points, and are 4 350 9.12 4.80 50-56 4 5/8x2 5 11 shipped already assembled in the Glands. 6 350 11.12 6.90 50-56 6 5/8x2 9 16 They are manufactured of 4140 grade 8 250 13.37 9.05 50-56 9 5/8x2 13 21 alloy steel, and are heat treated to a Rock- 10 250 15.62 11.10 50-56 12 5/8x2 17 26 wall "C"45/53 case hardness. Tee-head 12 150 17.88 13.20 50-56 16 5/8x2 20 28 bolts and gaskets are not included, but 14 250 20.25 15.30 53-56 20 5/8x2'/2 44 55 may be ordered separately. Recommend- 16 200 22.50 17.40 53-56 24 5/8x21/2 54 64 ed torque for set screws is 75 foot pounds, 18 200 24.75 19.50 53-56 24 5/8x21/2 62 72 and set screws on opposite sides of the glands should be tightened alternately. 20 200 27.00 21.60 53-56 28 5/8x3 76 91 Tee-head bolt hole size and spac- 24 150 31.50 25.80 53-56 32 5/8x3 103 118 ing are equal to MJ Glands as shown in *Not included in AWWA C110 AWWA C-111. Standard mechanical Joint gaskets as shown in C-111 should be used. TEES MJ GLAND 1 MINIIMEFI RH��f= N f _ Y a i Gland Weight (I' , Size Wt. Pack Gland Only IITice,,, „���' 2 5 3 3 7 4 x x 4 10 6 MJxMJxSwivel 6 16 10 Dimensions 8 25 16 Size X Y Weight 10 30 19 6 8.0 10.5 150 12 40 26 8x6 9.0 11.5 199 14 45 34 8 9.0 11.5 210 16 55 54 10x6 11.0 13.5 267 18 65 52 12x6 12.0 14.5 346 20 85 73 16x6 15.0 17.5 619 24 105 91 16x8 15.0 17.5 649 30 220 90 30x6 18.0 24.5 2070 36 301 127 All weights shown include the Swivel Gland ANSI/AWWA Cl 10/A21.10,ANSI/AWWA C111/A21.11 Tyler Utilities Division • 11910 CR 492 • Tyler,Texas 75706 • (800) 527-8478 20 Union Foundry Company • Box 309 • Anniston,Alabama 36202 • (800)226-7601 02/01/08 victaulic.com I Couplings I FireLock I Rigid I Style 009N I Publication 10.64 • 4.1 LISTINGS/APPROVAL Speciality Pipe Pipe Size Pressure Rating Pipe Size Pressure Rating Pipe Size I Pressure Rating cULus FM cULus FM cULus FM inches psi psi inches psi psi inches psi psi kPa kPa ! kPa kPa kPa kPa BLT 1'/4—2 300 365 EZT 1'/—2 300 365 MT 1'/—2 300 365 2068 2517 2068 2517 2068 2517 DF 1'/4-4 300 365 FF 1'/4-4 300 365 MLT 1'/4-2 N/A 365 2068 2517 2068 2517 2517 DT 1'/4-2 21608 3651FLF 1'/4-4 N/A 3651ST 1'/4-2 N/A 2517 175 175 365 365 EF 1'/+-4 1206 1206 FLT 1'/4-2 N/A 2517 STF 1'/4-4 N/A 2517 EL 1'/4-2 2068 3651FLTL 1'/4-2 N/A 3651TF 2'/4-4 N/A 256� ET40 1'/4-2 300 365 GL 1'/a-2 300 365 WLS 1'/4-2 300 365 2068 2517 2068 2517 2068 2517 EZF 3-4 300 365 MF 1'/4-4 300 365 WST 1'/4-2 N/A 365 2068 2517 2068 2517 2517 XL 1'/4-2 300 365 2068 2517 NOTES • BLT=BLT steel pipe manufactured by Allied Tube&Conduit Corp. • DF=DYNA-FLOW steel pipe manufactured by Allied Tube&Conduit Corp. • DT=DYNA-FLOW steel pipe manufactured by Allied Tube&Conduit Corp. • EF=EDDY FLOW steel pipe manufactured by Bull Moose Tube Co. • EL=EDDYLITE steel pipe manufactured by Bull Moose Tube Co. • ET40=Eddythread 40 steel pipe manufactured by Bull Moose Tube Co. • EZF=EZ-Flow steel pipe manufactured by Northwest Pipe Co. • EZT=EZ-Thread steel pipe manufactured by Youngstown Tube Co. • FE=Fire-Flo steel pipe manufactured by Youngstown Tube Co. • ELF=Fire-Line Flow steel pipe manufactured by Western International Forest Products Inc. • FLT=Fire-Line Threadable steel pipe manufactured by Western International Forest Products Inc. • FLTL=Fire-Line Threadable Light steel pipe manufactured by Western International Forest Products Inc. • GL=GL steel pipe manufactured by Wheatland Tube Co. • MF=Mega-Flow steel pipe manufactured by Wheatland Tube Co. • MT=Mega-Thread steel pipe manufactured by Wheatland Tube Co. • MLT=MLT steel pipe manufactured by Wheatland Tube Co • ST=STD wall pipe in accordance with ASTM A53. • STF=Steady Flow steel pipe manufactured by AMS Tube Corp. • TF=Tex-Flow steel pipe manufactured by Tex-Tube Co. • WLS=WLS steel pipe manufactured by Wheatland Tube Co. • WST=WST steel pipe manufactured by Wheatland Tube Company. • XL=XL steel pipe manufactured by Allied Tube&Conduit Corp. • • 10.64 7072 Rev G Updated 10/2014 ©2014 Victaulic Company.All rights reserved. i victaulic.com I Couplings I FireLock I Rigid I Style 009N I Publication 10.64 • 5.0 DIMENSIONS Style 009N z Y Z 44t 11111 :,��& 11=111 MIT Style 009N Pre-Assembled (Push On Condition) Style 009N Joint Assembled Dimensions Pre-assembled Actual Maximum Maximum Allow. Approx. Nominal Outside ' Working End Pipe End Bolt/Nut 9 (Push On Condition) Joint Assembled Weight Size Diameter I Pressure 7 Load 7 !Separation8 Size X Y X Y Z Each inches inches ' psi lbs. inches inches inches inches inches inches inches lbs. mm mm kPa N ' mm No. mm mm mm mm mm j mm kg - 1'/4 1.660 365 790 0.10 ' 44 x 2 3.13 5.00 2.75 5.00 • 2.00 1.4 32 42.4 2517 3514 2.54 2 M10x2 79 127 70 127 _ 51 0.6 1'h 1.900 365 1035 0.102 3/b x 2 338 5.13 3.00 5.13 2.00 1.5 40 48.3 2517 4604 2.54 M10x2 86 130 76 130 51 0.7 2 2.375 365 1616 0.12 3/s x21/2 4.00 5.63 3.50 5.63 2.00 1.9 50 60.3 2517. 7193 3.05 2 M10 x 21/2 102 143 89 143 51 0.9 21/2 2.875 365 2370 0.122 %x 2' 4.50 6.13 4.00 6.13 2.00 2.1 65 73.0 2517 10542 3.05 M10 x21/2 114 156 102 156 51 1.0 76.1mm 3.000 365 2580 0.12 2 %x2' 4.63 6.00 4.13 6.13 2.00 2.1 76.1 2517 11476 3.05 M10 x 2"1/2 118 152 105 156 51 1.0 3 3.500 365 3512 0.12 Mix 21/2 5.13 6.75 4.63 6.75 2.00 l 2.3 80 88.9 2517 15622 3.05 2 M10 x 21/2 130 171 117 171 51 1.0 4 4.500 365 5805 0.173/tix 2'/ 6.00 7.88 5.63 7.50 2.13 2.9 100 114.3 2517 25822 ' 432 2 M10 x 21/2 152 200 143 191 54 1.3 108.0 mm 4.250 365 5175 0.17 2 3/e x 21/2 5.63 738 5.38 7.38 2.13 3.1 108.0 2517 23020 432 M10 x21/4 152 1.87 137 187 54 1.4 5 5.563 365 8870 0.17 1/4 x 3 7.25 9.25 6.75 9.13 2.25 5.0 125 141.3 2000 39456 4.32 2 M12x3 184 235 171 232 57 2.3 5.250 365 7897 0.17 2 'h x 3 6.63 9.00 638 9.00 2.25 133.0 mm 4.8 133.0 2517 35106 4.32 M12x3 168 229 162 229 57 2.2 139.7 mm 5.500 365 8667 0.17 2 1/4 x 3 6.88 9.25 6.75 9.13 2.25 4.9 139.7 2517 38529 432 M12 x3 175 235 171 232 57 2.2 159.0mm 6.250 365 11192 0.17 2 'h x 3'/4 7.88 10.00 7.38 9.88 2.25 5.6 159.0 2517 49753 432 M12 x 3'/4 200 254 187 251 57 2.5 6.500 365 12105 0.17 'h x 3 Ya 8.00 10.25 7.75 10.13 2.25 6.0 165.1 mm 165.1 2517 53813 432 2 M12x31/4 203 260 197 257 57 2.7 6 6.625 365 12582 0.17 1/2x314 838 1038 7.88 10.13 2.25 6.0 150 168.3 I 2000 44469 4.32 2 M12 x 3'/4 213 264 200 257 57 2.7 216.0 mm 8.500 I 365 20712 0.17 2 5/s x 4 10.63 13.25 10.25 10.13 2.63 11.4 216.0 2517 55968 4.32 M16 x4 270 337 260 257 67 5.2 8 8.625 365 21326 0.17 5/a x 4 10.88 1338 10.25 13.13 2.50 11.4 200 219.1 1620 94863 4.32 2 M16 x4 276 340 260 333 64 5.2 7 Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.See the Listings/Approvals section of this publication for ratings on other pipe. 8 The allowable pipe separation dimension shown is for system layout purposes only.FireLock EZTM couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. 9 Number of bolts required equals number of housing segments. ' NOTES • When assembling FireLock EZTM couplings onto end caps,take additional care to make certain the end cap is fully seated against the gasket end stop.For FireLock EZT""Style 009N couplings,use FireLock No.006 end caps containing the"EZ"marking on the inside face or No.60 end caps containing the"QV EZ"marking on the inside face.Non-Victaulic end cap products shall not be used with Style 009N couplings.IMPORTANT:Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009N coupling.There is no interchanging of gaskets or housings between coupling styles. • Use Of Flushseal Gaskets For Dry Pipe Systems FireLock EZT""couplings are supplied with FireLock EZTM Grade"E"Type A gaskets.These gaskets include an integral pipe stop,that once installed provides the similar benefits as a FlushSeal gasket for dry pipe systems.It should be noted that standard Victaulic Flush-SealT"gaskets are not compatible and cannot be used with the FireLock EZT""couplings. • • 10.64 7072 Rev G Updated 10/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com I Couplings I FireLock I Rigid I Style 009N I Publication 10.64 • • 6.0 REFERENCE MATERIALS Publication 05.01:Seal Selection Guide I-009N/009H:Installation Instructions FireLock EZTM Rigid Coupling • • User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications.All products Victaulic products for a particular end-use application,in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications,as well as Victaulic performance,maintenance, Victaulic reserves the right to change product specifications,designs and standard safety,and warning instructions.Nothing in this or any other document,nor any verbal equipment without notice and without incurring obligations. recommendation,advice,or opinion from any Victaulic employee,shall be deemed to Installation alter,vary,supersede,or waive any provision of Victaulic Company's standard conditions Reference should always be made to the I-009N/I-009H Firelock EZ Rigid Coupling of sale,installation guide,or this disclaimer. Installation Instructions for the product you are installing.Handbooks are included with Intellectual Property Rights each shipment of Victaulic products,providing complete installation and assembly data, No statement contained herein concerning a possible or suggested use of any material, and are available in PDF format on our website at www.victaulic.com. product,service,or design is intended,or should be constructed,to grant any license Warranty under any patent or other intellectual property right of Victaulic or any of its subsidiaries Refer to the Warranty section of the current Price List or contact Victaulic for details. or affiliates covering such use or design,or as a recommendation for the use of such material,product,service,or design in the infringement of any patent or other intellectual Trademarks property right.The terms"Patented"or"Patent Pending"refer to design or utility patents Victaulic,FireLock EZTM Flush-SeaFTM,and Installation-ReadyTM are trademarks or or patent applications for articles and/or methods of use in the United States and/or other registered trademarks of Victaulic Company,and/or its affiliated entities,in the U.S.and/ countries. or other countries. • • 10.64 7072 Rev G Updated 10/2014 ©2014 Victaulic Company.All rights reserved. _; :DN STEEL PIPE-GROOVED COUPLINGS i • • 1 Coupling 0 m ® yds LPCB SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 75 fOrta'. Style 75 is available where moderate pressures are expected or weight considerations are a factor. Up to 50%lighter in weight than the Style 77, *° the Style 75 coupling is recommended for service up to 500 psi/3450 kPa depending on size. Housings are cast in two identical pieces in all sizes. Hot-dip galvanized and special coatings are available for all sizes. im„_„ • ins x• P"I ea Exaggerated for clarity MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536,grade 65-45-12. Ductile iron conforming to ASTM A-395,grade 65-4545, is available upon special request. Housing Coating: Orange enamel. • Optional: Hot dipped galvanized and others. Gasket: (specify choice*) • Grade"E"EPDM EPDM (Green color code).Temperature range-30°F to+230°F/-34°C to+110°C. Recommended for hot water service within the specified temperature range plus a variety of dilute acids,oil-free air and many chemical services. UL classified in accordance with ANSI/NSF 61 for cold+86°F/+30°C and hot+180°F/+82°C potable water service. NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade"T"nitrile Nitrile(Orange color code).Temperature range-20°F to+180°F/-29°C to+82°C. Recommended for petroleum products,air with oil vapors,vegetable and mineral oils within the specified temperature range;except hot,dry air over+140°F/+60°C and water over +150°F/+66°C. NOT RECOMMENDED FOR HOT WATER SERVICES. * Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. • Bolts/Nuts: Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. • JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved • Date www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2006 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. ictau I.0 DC1l U ,r; ,. 1 CARBON STEEL PIPE-GROOVED COUPLINGS U b,U Coupling STYLE 75 DIMENSIONS Max.Work Allow.Pipe Bolt/Nut@ Approx. Size Pressure* Max.End Load* End Sep.t Deflect.Fr.Cit No-Size Dimensions-Inches/mm Wgt.Each . Tr Actual ominal Outside x;' Size Diameter Per Pipe Inches Inches psi Lbs. Inches Cplg. In./Ft. Lbs. mm mm kPa N mm Deg. mm/rn Inches X Y Z - kg 1 1315 500 680 0-0.060.57 238 427 1.77 13 2°-43' 2-3/8x2 25 33.4 3450 3025 0-1.6 48 61 108 45 0.6 11/4 1.660 500 1080 0-0.060.45 2.68 4.61 1.77 1.4 32 42.2 3450 4805 0-1.6 2°-10' 38 2-3/8 x 2 68 117 45 0.6 1P/ 1.900 500 1.420 0-0.06. 0 40 2.91 4.82 1.77 1.5 1`-56' 2-3/8x2 40 48.3 3450 6320 0-1.6 33 74 122 45 0.6 2 2.375 500 2.215 0-0.060.32 3.43 5.22 88 , 1.7 1°-31' 2-3/8x2 50 60.3 3450 9860 0-1.6 26 87 133 48 0.8 2 Yz 2.875 500 3.245 0-0.060.26 3.88 5.68 1.88 1.9 1`-15' 2-3/8x2 65 73.0 3450 14440 0-1.6 22 98 144 48 0.9 3.000 500 3.535 0-0.06 0.26 4.00 5.90 1.88 1.9 76.1 mm# 1°-12' 2-3/ax2 76.1 3450 15730 0-1.6 22 102 150 48 0.9 3 3.500 500 4.800 0-0.061°_2, 0.22 2-''/z x 23/4 4.50 7.00 1.88 2.9 80 88.9 3450 21360 0-1.6 18 114 178 48 1.3 3 1 4.000 500 6.300 0-0.060.19 5.00 7.50 1.88 2.9 0°-54' 2-/x21/4 90 101.6 3450 28035 0-1.6 16 127 191 48 1.3 4 4.500 500 7.950 0-0.130.34 5.80 8.03 2.13 4.1 100 114.3 3450 35380 0-3.2 1°-36' 28 2--1/2 x 2 3/a 147 204 54 1.9 1 08.0 mm 4.250 450 6.380 0-0.13 0.35 5.55 7.79 2.13 3.7 108.0 3100 28395 0-3.2 1°-41' 29 2-12 x 70.0 141 198 54 1.7 4'/ 5.000 450 8.820 0-0.131°_26' 0.25 2-5/8 x 31/ 6.13 9.43 2.13 5.5 120 127.0 3100 39250 0-3.2 21 156 240 54 2.5 5 5.563 450 10.935 0-0.130.27 6.88 10.07 2.13 5.8 1°-18' 2-5/xx31/4 125 141.3 3100 48660 0-3.2 23 175 256 54 2.6 33.0 mm 5.250 450 9.735 0-0.13 0.28 6.55 9.37 2.13 6.0 133.0 3100 43325 0-3.2 1 -21 24 2-16 x 82.5 166 238 54 2.7 5.500 450 10.6650.28 6.80 9.59 2.13 6.3 139.7mm# 1 0-0.13 °-18' 2-5/8x3'// 139.7 3100 47460 0-3.2 24 173 244 54 2.9 52.4mm 6.000 450 12.735 0-0.13 1°-12' 0.21 2-5/8x3'/a 7.38 10.48 1.88 6.2 152.4 3100 56670 0-3.2 18 187 266 48 2.8 6 6.625 450 15.525 0-0.131.-5, 0.23 8.00 11.07 2.13 7.0 150 168.3 3100 69085 0-3.2 18 2-5/nx3Ya 203 281 54 3.2 Continued on page 3. *t @#Refer to notes on page 3. Y 1.4-Z sl is �� hili �o- 1111 www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2006 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. ICta -.. nc nG 0 DC1/ LI CARBON STEEL PIPE-GROOVED COUPLINGS U b,u Coupling STYLE 75 DIMENSIONS Max.Work Allow.Pipe Bolt/Nut@ Approx. Size Pressure* Max.End Load* End Sep.+ Deflect.Fr.CLi No-Size Dimensions-Inches/mm Wgt.Each Nominal Outside Size Diameter Per Pipe :.rhes Inches psi Lbs. Inches Cplg. In./Ft. Lbs. m mm kPa N mm Deg. mm/m Inches X Y Z kg 4 ',5. 59.0 m m 6.250 450 13.800 0-0.13 0.24 7.63 10.49 2.13 6.8 1°-9' 2-16x82.5 159.0 3100 1 61405 0-3.2 20 194 266 54 3. 65.1 mm# 6.500 450 14.940 0-0.13 0.23 7.84 10.66 2.06 7.2 1°-6' 2-5/ax3Ya 65.1 3100 66483 0-3.2 19 199 271 52 33 203.2mm# -t- 8 000 450 1 22.635 0-0.13 0`-54' 0.16 2-3/ax4/a 9.72 13.33 2.31 12.6 203.2 3100 i 100725 0-3.2 13 247 339 58 5.7 8 8.625 450 1 26.280 0-0.130°-50' 0.18 10.34 13.97 2.32 12.4 200 219.1 3100 _ 116945 0-3.2 14 2-3/ax4Ya 263 355 59 5.6 254.0 mm i 10.000 350 27.500 0-0.13 -43' 2-0.15 12.16 5.81 2.53 20.8 0` '/8 X 51/2 309 402 64 9.4 254.0 2400 122375 0-3.2 • 11 304.8 mm# 12.000 350 i 39.500 0-0.13 0°-36' 0.13 2-%a x S'/2 14.16 17.69 2.53 23.6 304.8 2400 175775 0-3.2 9 360 449 64 10.7 * Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.Contact Victaulic for performance on other pipe. WARNING:FOR ONE TIME FIELD TEST ONLY,the Maximum Joint Working Pressure may be increased to 1 1/2 times the figures shown. t Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe.Figures for standard cut grooved pipe may be doubled.These figures are maximums;for design and installation purposes these figures should be reduced by:50%for 34-31/2'%20-90 mm;25%for 47100 mm and larger. @ Number of bolts required equals number of housing segments. Metric thread size bolts are available(color coded gold)for all coupling sizes upon request.Contact Victaulic for details. Y > �-Z 1C1111""Nas I!J ,A1 ja 4111 - �1 11111 www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2006 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. 1Ctaul1C DCl/ LI CARBON STEEL PIPE- GROOVED COUPLINGS • g Coupling STYLE 75 WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. • ( III II11IIIIIIII11111111IIIIIIIIIIII 1111 WCAS-6QAQQT For complete contact information,visit www.victaulic.com 06.05 1470 REV H UPDATED 9/2006 ictaul1C VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2006 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. nc n� 14795 S.W. 72'd OR D /:....\-, PHONE PORTLAND,036020 40204e FAX 503-620-1058 FIRE, INC. CCB# 64174 FIRE PROTECTION CONTRACTORS PIPE RINGS -'\‘'i(Z�j;mVV I rl Fig. 69 Adjustable Swivel Ring, Tapped Per NFPA Standards Size Range:1/2"through 8" Material:Carbon steel Finish:❑ Galvanized Service:Recommended for suspension of non-insulated stationary pipe line. %...:7- Maximum ----Maximum Temperature:650°F Approvals:Complies with Federal Specification A-A-1192A(Type 10) WW-H-171-E(Type 10),ANSI/MSS SP-69 and MSS SP-58(Type 10). UL Listed and FM Approved (Sizes 3/4"-8"). Features:': • Threads are countersunk so that they cannot become burred or damaged. • Knurled swivel nut provides vertical adjustment after piping is in place. • Captured swivel nut in the1/2"through 6"sizes.The capture is permanent in the bottom portion of the band,allowing the hanger to be opened during installation if desired, but not allowing the nut to fall completely out. Ordering:Specify size,figure number and name. Note:The acceptability of galvanized coatings at temperatures above 450°F is at the • discretion of the end user. Metric nut available upon request.Non-captured nut also available upon request. mpg , � fA gilil 1 • cB 1'/4"through 8"pipe 1/2"through 1"pipe FIG. 69: LOADS (LBS) • WEIGHT (LBS) • DIMENSIONS (IN) Pipe Size Max Load Weight Rod Size A B C F 1/2 0.10 2' 2 19/16 3/4 0.10 23/4 1'/e 15/16 1 300 0.10 29/16 1"As s 1 11/4 0.10 2% 13/4 11/2 0.10 % 2% 1% 7/8 2 0.11 31/4 23/8 11/8 21/2 525 0.20 4 23/4 15/6 3 0.20 313/16 215/16 13/16 4 650 0.30 411/16 3'3/s 5 0.54 55/6 4% 19/6 6 1,000 0.65 1/2 61/6 59/16 21/4 8 1.00 8 7 21/6 Note:Reflects changes in rod diameter from previously published data per recent revisions in MSS-SP-58&69 PROJECT INFORMATION APPROVAL STAMP Project: j Approved Address: ❑Approved as noted Contractor: ❑ Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: Catalog PH-2008 HANGER RODS ®ANNIIkT Fig. 146 g Continuous Threaded Rod Size Range:'/4"through 1'/2"Stocked in six,ten,and twelve foot lengths. Other even foot lengths can be furnished to order. Material:Carbon steel; rod threaded complete length. t tl t, t,,tprst—qtt+4fii•iI € , Finish:Cl Plain or❑galvanized. Maximum Temperature:650°F. Ordering:Specify rod diameter and length,figure number, name and finish. Note:The acceptability of galvanized coatings at temperatures above 450°F is at the discretion of the end user. �• Length v iNOMMENNOSONNOMMONNOMM f A FIG. 146: LOADS (LBS) • WEIGHTS(LBS) DIMENSIONS (IN) Rod Size Threads Max Load Weight A per Inch 650° F per Ft. 1/4 20 240 0.12 3/B 16 730 0.30 1/2 13 1,350 0.53 5/e 11 2,160 0.84 3/4 10 3,230 1.20 9 4,480 1.70 1 8 5,900 2.30 1'/4 7 9,500 3.60 1'/2 6 13,800 5.10 Note:Other rod sizes available upon request.Class 2 fit is available upon request. PROJECT INFORMATION APPROVAL STAMP Project: ❑Approved Address: ❑Approved as noted Contractor: ❑ Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: Catalog P11-2008 STEEL PIPE CLAMPS F Fig. 212 Medium Pipe Clamp Size Range:'/2"through 30" Material:Carbon steel c0 us Finish:0 Plain oro Hot-Dip Galvanized with Zinc Plated Bolts&Nuts LISTED ' ` Service:Recommended for suspension of cold pipe lines or hot lines where no insulation is required. .. Maximum Temperature:Plain 750°F,Galvanized 450°F APPROVED r, Approvals:Complies with Federal Specification A-A-1192A(Type 4) WW-H-171-E(Type 4),ANSI/MSS SP-69 t and MSS SP-58(Type 4).UL,ULC Listed and FM Approved(Sizes 3/4"-8"). Installation:Normally used with weldless eye nut Fig.290 or eye rod. F 1 b Features: i MI j cii • Clamps tightly to pipe. o • Wide range of sizes. • Equal gap design on many sizes. Ordering:Specify pipe size,figure number,name and finish. B Note:The"C"gap dimension ensures adequate clearance at the top attachmentIMI• j CI point for a weldless eye nut or other appropriate rod attachment.This gap may 1 or may not be present on the bottom portion of the clamp.If different loads or Note:This picture is representative of a typical Figure 212.Distance dimensions are required,refer to Fig.42 SD non-standard two bolt pipe clamp. between clamp ears beneath pipe may or may not be equal to—upper gap. FIG. 212: LOADS (LBS) • WEIGHT (LBS) • DIMENSIONS (IN) Pipe Span Max Load Rod G For Service Temp Weight B C Take Out H D F Size Ft. Width 650° F 750° F 1/2 0.29 1 13/6 11%2 123/32 3/40.33 11/4 125/32 7* 500 1'/a 121/32 1 — 0.35 1 13/e 129/32 5/6 11/4 0.38 17A6 /2 15/8 131/32 25/32 114 9* 800 0.43 19/6 111/6 23/32 2/32 1 2 10* 1.10 21/8 21/8 23/4 23/4 21/2 11* 1.20 25/8 25/8 31/4 31/4 3 12* 1,040 930 1.40 27/8 5/e 27/a 31/2 31/2 1/2 31/2 13* 1.50 33/,6 33/16 313A6 313/16 4 14* 1.80 31/2 31/2 41/4 41/4 5 16* 2.60 43/6 3/4 43/6 415A6 415A6 5/8 11/4 6 17* 5.40 47/a 4% 53/4 53/4 8 19* 1,615 1,440 6.50 6 1/4 6 6% 6% 3/4 11/2 10 22* 13.60 77/16 7'/16 89/16 89/16 2 12 23* 15.20 87/6 1 87A6 99A6 99/16 2,490 2,220 14 20 20.50 91/4 1 91/4 105/e 105/8 /a 16 15 22.30 101/4 1/a 101/4 115/8 1.15/8 t 18 15 31.60 115/a 11/4 11% 13 13 1 2/2 20 12 3,060 2,730 35.80 12% 13/. 12% 141/8 141/8 11/a 24 12 53.10 151/4 15/8 151/4 16/8 16/8 11/4 3 30 9 3,500 3,360 113.90 19 2 19 211/8 211/e 1% 4 Clamps may be furnished with square ends."Span"represents the maximum recommended distance between hangers on a continuous&straight run of horizontal standard weight steel pipe filled with water.In all cases,verify that chosen location of hangers does not subject hangers to a load greater than the maximum recommended load shown above.For vapor service,the presence of fittings or insulation,and other weights and types of pipe,spans may either increase or decrease.In all cases,verify that chosen location of hanger does not subject hangers to a load greater than the maximum recommended load shown.*Indicates that span represents the maximum span for water filled pipe. PROJECT INFORMATION APPROVAL STAMP Project: 0 Approved Address: 0Approved as noted Contractor: 0 Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: PH-1.15 SWI L-STRULI PIPE & CONDUIT SUPPORT NYAIr ABRA.OLINTERNAMPOLL ❑AS 1100AS ❑EG ❑SS ❑ZTC RIGID STEEL CONDUIT AND PIPE CLAMPS Also For IMC and GRC. Design Load PRE-ASSEMBLED RIGID STEEL f CONDUIT CLAMPS AND PIPE CLAMPS z0 D. Load Std Wt/100 �� Size Size Rating Pkg pcs 3/e" 0.675 400 100 10 /z" 0.840 400 100 11 3/4" 1.050 600 100 15 1 /' 1 1.315 600 100 17 J ri) Pullout 1W 1.660 600 100 19 11/2" 1.900 800 50 29 (Vertical) 2" 2.375 800 50 34 2W' 2.875 800 50 40 3 3.500 800 50 47 3'h" 4.000 1000 25 62 4" 4.500 1000 25 67 5" 5.563 1000 25 80 Slip Along C - Slip Thru 6" 6.625 1000 25 102 (Transverse) _ 8" 8.625 1000 25 130 (Longitudinal) 10" 10.750 1000 25 143 12" 12.750 1000 25 174 Nominal Average Ultimate Loads Design Loads Pipe Size Slip Thru(lbs) Slip Along(lbs) Pullout(lbs) Slip Thru(lbs) Slip Along(lbs) Pullout(lbs) 638 231 2,721 213 77 907 3/4" 427 507 2,975 142 169 992 1 394 523 2,417 131 174 806 114" 1,061 450 3,480 354 150 1,160 1'/z" 1,004 1,007 4,693 335 336 1,564 2" 1,216 1,518 4,715 405 506 1,572 21/2" 862 1,645 4,830 287 548 1,610 3 1,488 1,357 3,952 496 452 1,317 3W' 1,302 1,593 4,470 434 531 1,490 4" 1,555 1,727 4,516 518 576 1,505 5" 1,232 1,702 3,938 411 567 1,313 6" 1,219 1,689 4,592 406 563 1,531 8" 1,741 1,992 6,053 580 664 2,018 Std Pkg&Wt/100 pcs:See chart above. LEGEND: GR:Powder Coated Supr-Green EG:Electro-Galvanized AL:Aluminum HG:Hot Dipped Galvanized PL:Plain SS:Stainless Steel ZTC:Zinc Trivalent Chromium PROJECT INFORMATION APPROVAL STAMP Project: ❑Approved Address: ❑Approved as noted Contractor: ❑ Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: 8/08 ANVIL-STRUT- CHANNEL )j)Anivit_ LEGEND: GR:Powder Coated Supr-Green EG:Electro-Galvanized PG:Pre-Galvanized AL:Aluminum HG:Hot Dipped Galvanized PL:Plain SS:Stainless Steel ZTC:Zinc Trivalent Chromium AS 200 15/8" X 15 8 ' (41.28) -� I 3/8"(9.53) ` 12 Gauge Channel wt./100 ft. - 194# I 9/32".14 (7.14 Stocked in pre-galvanized, plain and powder coated Supr-Green, f in both 10 and 20 ft. len ths. Other materials,finishes and (41.28)8" 1.8"118) g 4 4 x 7/80 lengths are available upon request. 0.923-3! (22.23) (23.44) See page 16 for welded combinations. 4' '" (mm)millimeters Y PROPERTIES OF SECTION I=Moment of Inertia S=Section Modulus r=Radius of Gyration Wt./Ft. Area of Section X-X Axis Y-Y Axis Lbs kg Sq.In. Sq.Cm. I in' I cm' Sin' S cm3 r in. r cm, I in' I cm' S in3 S cm3 r in. r cm. AS 200 1.94 0.88 0.544 3.510 0.180 7.492 0.195 3.195 0.575 1.461 0.233 9.698 0.287 4.703 0.655 1.664 AS 200BTB 3.88 1,76 1.088 7.019 0.896 37.294 0.570 9.341 0.908 2.306 0.466 19.396 0.574 9.406 0.655 1.664 AS 200 BEAM AND COLUMN LOADS Max Load of Static Beam Load (X-X Axis) Span or Anvil-Strut- Column Loaded Column Catalog # Allowable Uniform Load @ Deflection @ Uniform Load Uniform Load @ C.G. 25,000 PSI(1758 Kg/cm2) 25,000 PSI(1758 Kg/cm2) @'/z4o @ I/360 In mm Lbs kg Lbs kg In mm Lbs kg Lbs kg 12 305 AS 200 7,109 3,225 3,249 1,474 0.014 0.356 ** ** ** ** AS 200 BTB 14,862 6,741 2,610*** 1,184 0.008 0.203 ** ** ** ** 18 457 AS 200 6,549 2,971 2,166 982 0.031 0.787 ** le* ** ** AS 200 BTB 14,402 6,533 2,610*** 1,184 0.018 0.457 ** ** ** ** 24 610 AS 200 5,938 2,693 1,625 737 0.055 1.397 ** ** ** ** AS 200 BTB 13,919 6,314 2,610*** 1,184 0.032 0.813 ** ** ** ** 30 762 AS 200 5,337 2,421 1,300 590 0.086 2.184 ** ** 1,257 570 AS 200 BTB 13,473 6,111 2,610*** 1,184 0.050 1.270 ** ** ** ** 36 914 AS 200 4,771 2,164 1,083 481 0.124 3.150 ** ** 873 396 AS 200 BTB 13,090 5,938 2,610*** 1,184 0.072 1.829 ** ** ** ** 42 1,067 AS200 4,242 1,924 928 421 0.169 4.293 ** *1r641 291 AS 200 BTB 12,771 5,793 2,610*** 1,184 0.099 2.515 ** ** ** ** 48 1,219 AS 200 3,745 1,699 812 368 0.220 5.588 737 334 491 223 AS 200 BTB 12,511 5,675 2,610*** 1,184 0.129 3.277 ** ** ** ** 60 1,524 AS 200 3,012 1,366 650 295 0.344 8.738 471 214 314 142 AS 200 BTB 11,685 5,300 1,899 861 0.202 5.131 ** ** 1,566 710 72 1 829 AS 200 2,514 1,140 542 246 0.496 12.598 327 148 218 99 AS 200 BTB 10,078 4,571 1,582 718 0.291 7.391 ** ** 1,087 493 84 2,134 AS 200 2,136 969 464 210 0.675 17.145 240 109 160 73 _ AS 200 BTB 8,180 3,710 1,356 615 0.396 10.058 1,199 544 799 362 96 2,438 AS 200 1,834 832 406 184 0.882 22.403 184 83 123 56 AS 200 BTB 6,291 2,854 1,187 538 0.517 13.132 917 416 611 277 AS 200 1,585 719 361 164 1.116 28.346 145 66 97 44 108 2,743 AS 200 BTB 4,971 2,255 1,055 479 0.655 16.657 725 329 483 219 120 3,048 AS 200 * * 325 147 1.378 35.001 117 53 78 35 AS 200 BTB 4,026 1,826 949 430 0.808 20.523 587 266 391 177 180 4,572 AS 200 * * 217 98 3.099 78.715 52 24 35 16 AS 200 BTB * * 633 287 1.819 46.203 261 118 174 79 240 6,096 AS 200 * 163 74 5.510 139.954 29 13 19 9 AS 200 BTB * 474 215 3.233 82.118 147 67 98 44 For Beam and Column Loading Data and load reduction information for channel with holes and concentrated loads,see notes on page 17. AS-1.10 /ANVIL-STR ((�CHANNEL 4nivABRANDO, � ❑AS 200 ❑PL, ❑GR, ❑PG, ❑Other ❑AS 200EH ❑PL, ❑GR, ❑PG, ❑Other SOLID WITH ELONGATED HOLES . 9/16"X 11/8"DIA HOLES f f 15/e" 15/e"MIME 7/16" 2" Wt/100 Ft 190 lbs. Wt/100 Ft 185 lbs. ❑AS 200KO ❑PL, ❑GR, ❑PG, ❑Other ❑AS 200H ❑PL, ❑GR, ❑PG, ❑Other WITH KNOCK OUT WITH HOLES 7/8" DIA KNOCKOUTS 9/16"DIA HOLES 15/8" • 15/8" • • • O 3" 6" 13/16" 17/8" 1/4"dia.holes available AS 200H MOD Wt/100 Ft:190 lbs. Wt/100 Ft:186 lbs. ❑AS 2005 ❑PL, ❑GR, ❑PG, ❑Other ❑AS 200H3 ❑PL, ❑GR, ❑PG, ❑Other WITH LONG SLOTS 4 s= WITH HOLES ON ALL 3 SIDES 13/32"x 3"SLOTS 9/16"DIA HOLES 15%e" 15 • • • 0 _I 1/2"H 4" 13/16" 17/8" Holes on all three sides are 17/8"on center. Wt/100 Ft:185 lbs. Wt/100 Ft:179 lbs. LEGEND: GR:Powder Coated Supr-Green EG:Electro-Galvanized PG:Pre-Galvanized AL:Aluminum HG:Hot Dipped Galvanized PL:Plain SS:Stainless Steel ZTC:Zinc Trivalent Chromium PROJECT INFORMATION APPROVAL STAMP Project: ❑Approved Address: ❑Approved as noted Contractor: ❑Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: AS-1.10 bNVR -sTruTj CHANNEL ®ANtvii, ❑AS 200BTB ❑PL, ❑GR, ❑PG, ❑Other ❑AS 200STS ❑PL, ❑GR, ❑PG, ❑Other WELDED Ina WELDED H1518— I 151H- 1. I „17/... 31v„..8 1E Wt/100 Ft 380 lbs. Wt/100 Ft:380 lbs. ❑AS 200EH BTB ❑PL, ❑GR, ❑PG, ❑Other ❑AS 200STSR Cl PL, ❑GR, ❑PG, ❑Other WELDED WITH ELONGATED HOLES WELDED --15/8"-11.-151...-1 9/16"X 11/6"DIA HOLES rtvl1 F-311,28: 3'/<" 1518 EMI= glE 3'/a" H 7/16" 2" 1 0 Wt/100 Ft 370 lbs. Wt/100 Ft 380 lbs. ❑AS 200H BTB ❑PL, ❑GR, ❑PG, ❑Other ❑AS 200BTS ❑PL, ❑GR, ❑PG, ❑Other WELDED WITH HOLESWELDED .-- I---1518'—.I I--1%"—H 19/16" ri DIA HOLES 1 /B' t I R/8 31" 15/8" A A • O 3q4.. 13/16" 17/s" 1 E Wt/100 Ft:372 lbs. Wt/100 Ft 380 lbs. LEGEND: GR:Powder Coated Supr-Green EG:Electro-Galvanized PG:Pre-Galvanized AL:Aluminum HG:Hot Dipped Galvanized PL:Plain SS:Stainless Steel ZTC:Zinc Trivalent Chromium PROJECT INFORMATION APPROVAL STAMP Project: ❑Approved Address: ❑Approved as noted Contractor: ❑Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: AS-1.10 —......... _________—__ -(ort_ Rit',i'lLue, Designation: A 307—04€' 03 - 26 r �o 5 c.) X11 _ INTERNATIONAL Standard Specification few. Carbon Steel Bolts and Studs, 60 000 PSI Tensile Strengths This standard is issued under the fixed designation A 307; the number immediately following the designation indicates the year of original adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapprovat A superscript epsilon(a) indicates an editorial change since the last revision or reapproval. This standard has been approved for use by.agencies of the Department of Defense. a' Nore—Sections 2.2 and 3112 were editorial¢`revised in October 2006. • 1. Scope'sA Nuts of other grades and styles having specified proof loadstresses strses(Sped- fication A 563,Table 3)greater than the specified grade and style of nut are also 1.1 This specification2 covers the chemical and mechanical suitable. requirements of three grades of carbon steel bolts and studs in 1.4 The values stated in inch-pound units are to be regarded sizes 1/4 in. (6.35 mm) through 4 in. (104 mm). The fasteners as the standard. The values,given in parentheses are for are designated by "Grade" denoting tensile strength and information only: intended use, as follows: 1.5 Supplementary Requirement S1 of an optional nature is Grade Description provided, which describes additional restrictions to be applied when bolts are to be welded. It shall apply only when specified. Grade A Bolts and studs having a in the inquiry, order, and contract, minimum tensile strength of • - 60 ksl(414 MPa)and In- 1.6 Terms used in this specification are defined in Tetmi- tended for general,applica- nology F 1789 unless otherwise defined herein. lions, Grade B Bolts and studs having a 2. Referenced Documents tensile strength of 60 to 100 ,ksi(414 to 690 MPa)and 2.1 ASTM Standards: 3 • Intended for flanged}pints in A 36/A 36M Specification for Carbon Structural Steel • piping systems with Cast iron ' flanges,and . A 153/A 153M Specification for Zinc Coating(Hot-Dip)on Grade C Nonheaded anchor botts, Iron and Steel Hardware either bent or straight,hay. A 370 Test Methods and Definitions for Mechanical Testing ing properties conforrming to Specification A 36/A 36M of Steel Products (tensile strength of 5B to 80 A 563 Specification for Carbon and Alloy Steel Nuts • ksi(apo to 550 MOO and -A 706/A 706M Specification for Low-AlloySteel De- intended for structural an- P chorage purposes. formed and Plain Bars for Concrete Reinforcement 1.1.1 The term studs includes stud stock, sometimes re A 751 Test Methods, Practices, and Terminology for ferred to as threaded rod.' Chemical Analysis of Steel Products . 1,2 This specification does not cover requirements for B 695 Specification for Coatings of Zinc Mechanically machine screws,' thread cutting/forming screws, mechanical Deposited on Iron and Steel expansion anchors or similar externally threaded fasteners. D 3951 Practice for Commercial Packaging . 1.3 Suitable nuts are covered in Specification A 563.Unless F 606 Test Methods for Determining the Mechanical Prop- otherwise specified, the grade and style of nut for each grade of ernes of Externally and Internally Threaded Fasteners, • fastener, of all surface finishes, shall be as follows; crashers, Direct Tension Indicators, and Rivets Fastener Grade and Size Nut Grade and Style" F 1470 Guide for Fastener Sampling for Specified Mecham- A,C,1/4 to 1ii In. A,hex cal Properties and Performance Inspection A,C,over 11 to 4 in. A,heavy hex F 17.89 Terminology for F16 Mechanical Fasteners • B,1/4 to 4 in. A,heavy hex 2.2 ASME Standards:4 B 1.1 Unified Screw Threads 'This specification is under the jurisdiction of ASTM Committee F16 on Fasteners and istbe direct responsibility of Subcommittee F16.02 on Steel Bolts, 3 For referenced ASTM standards, visit the ASTM website, www.astm.org,or Nuts,Rivets,and Washers. - contact ASTM Customer Service at service@astm.org.For Annual Book of ASTM Current edition approved Aug. 1, 2004. Published August 2004. Originally Standards volume information,refer to the standard's Document Summary page on approved in 1947.Last previous edition approved in 2003 as A 307-03. the ASTM website. 3 For ASME Boiler and Pressure Vessel Code applications see related Specifi- 4 Available from American Society of Mechanical Engineers(ASME),ASME cation SA-307 in Section II of that Code. International Headquarters,Three Park Ave.,New York,NY 10016-5990. 4 '"A Summary of Changes section appears at the end of this standard. ' Copyright©ASTM International,100 Herr Harbor©rive,PO Box C700,West Conshohocken,PA 19428-2959,United States. 5 . .;4 ` A307-04E1 B 18.2.1 Square and Hex Bolts and Screws 4.5.4 When no q preference is specified, the supp7 `'-;: B 18.24 Part Identifying Number (PIN) Code System Stan- furnish either a hot-dip zinc coating in accordan dard for B 18 Fastener Products • Specification A 153/A 153M, Class C or a mechanic 2.3 Military Standard: posited zinc coating in,accordance with Specificatioi MIL-STD 105 Single Sampling Plan for Normal Inspec- Class 50.15lreaded components(bolts and nuts)shall b .1 tion by the same zinc-coating process and the supplier's c limited to one process per item with no mixed prose: 3. Ordering Information lot. .. ' : 3.1 Orders for externally threaded fasteners (including'nuts . and accessories) under this specification shall 'include the 5. Chemical Composition i following: 5.1 Grade A and B bolts and studs shall have a heat 3.1.1 ASTM designation and year of issue, conforming.to the requirements specified in Table 1 t ;'` ' 3.1.2 Name of product, bolts or studs; and bolt head style, the steel producer's heat analysis:- ' - that is, hex or heavy hex, 5.2 The purchaser shall have the option of col 1;•••---;* 3.1.3 Grade, that is,A, or B, or C. If no grade is specified, product analyses on finished bolts in each lot, whi t;^ '' Grade A is furnished. conform to the product analysis specified in Table 1. i; :.. 3.1.4 Quantities (number of pieces by size including nuts), 5.3 In case of conflict or,for referee purposes, the . 3.1.5 Fastener size and length, analysis shall take precedence. . , . 3.1.6 Washers--Quantity and size (separate from bolts), 5.4 Bolts and studs are.customarily furnished from 1 ...'f';:;,'1". 3.1.7 Zinc Coating-Specify the zinc-coating process re- which case individual heats of steel cannot be identif quired, for examples hot-dip, mechanically deposited, or no 5.5 Application of heats of steel to which bismu preference:(see 4,5). : • nium, tellurium, or lead has been intentionally added 3.1.8 Other Finishes-Specify. other protective finish, if be permitted for Grade B bolts and studs. required. 5.6.Chemical ,analyses shall be performed in acc E' `M 3.1.9 Specify if inspection at point of manufacture is•re- with Test'Methods, Practices, and Terminology A 751 '" quired,u3red, 6. Mechanical Properties r ,_ cl� 3.1.10 Specify if certified test report is required (see 8.2), p a° and • - 6.1 Grades A and B bolts and studs shall conforr ll' 3.1.11 Specify additional testing (8.3) or special require- hardness specified in Table 2. ':; IT' ments. ., 6.2 Grade A and B bolts and studs 11 in.in diameter 3.1.12 For establishment of a part identifying system, see other than those excepted in 6.4, shall be tested full ASME B 18.24.. . shall confoirn to the requirrements for tensile strength s in Table.3: • • 4. Materials and Manufacture - 6.3, Grade A and B bolts and studs larger than 1? 4.1 Steel for bolts and studs shall be made by the open- diameter,other.than•t.hc a excepted in 6.4, shall prefe. hearth, basic-oxygen, or.electric-furnace process. tested full-size and:when equipment of sufficient cal ` ` 4.2 Bolts shall be produced by hot or cold forging. of the available, and shall conform,:to;the requirements foi i heads or machining from bar stock. strength specified in Table 3. When..equtpment Of s 4.3. Heat Treatment: ca aci for full-size bolt testingis n t available or v f. � P tY�. . ., P >.: 4.3.1 Cold headed fasteners with head configurations other length of the bolt makes full-size testing impractic4l,m than hex shall be stress relief annealed. . .; specimens, shall_ be.tested and..shall conform .t<o. the .4.3.2 Stress relieving of hex head fasteners shall be at the ments specified in Table 4; i. manufacturer's option. . : . 6.4 Grades A and B bolts andstuds Jess than three di 4.4 Bolt and stud threads shall be rolled or Cut. in length or bolts with drilled:or undersize heads s are no. 4.5,Zinc Coatings, Hot-Dip and Mechanically Deposited: to tensile tests. ,. . . • 4.5.1 When zinc-coated fasteners are required, the pur- 6.5 Grade C nonheaded anchor bolts shall be test( 1 chaser shall_specify the zinc-coating process,'for exaniple hot machined specimens and shall conform to the tensile pi r i dip, mechanically deposited, or no preference. specified for bars in Specification A 36/A 36M. Prope I 4.5.2 When hot-dip is specified, the fasteners 'shall be zinc-coated by the hot-dip process in accordance with the TABLE 1 Chemlcaj Requirements for Grades A and B Bt requirements of Class,C of Specification A 153/A 153M.• stride 4.5.3 When mechanically deposited is specified, the fasten- Heat Analysis Product An, ers shall be zinc-coated by the mechanical-deposition process carbo,,max 0,29 0:93 in accordance with the requirements of Class 50 of Specifica- . Manganese.max . 1.20. , ; . . . 1-25 tion B 695. Phosphorus,max, . . 0.04 - 0.041 Sulfur,max . Grade A 0.15 A Grade B 0.05 0.051 'Available from Stsnderdizauon Documents Order Desk,Bldg.4 Section D,700 A Resutfurized steel Is not subject to rejection based on product a Robbins Ave.,Philadelphia,PA 19111-5094,Attu:NPODS. suffur. • 6 .r.i' ormmummiminEmmoimmommomb, I- c4WA3O7_04151 TABLE 2 Hardness Requirements for Bolts and Studs TABLE 4 Tensile Requirements for Machined Specimens • Grade Length,In. Hardness" Grade A ' Grade B Grade C • 0 Brinell Rockwell B Tensile strength,ksi 60 min 60-100 58-80 • min max min • max Yield point,min ksi ,.. 36 Elongation In 2 in.,. 18 18 23 • • A Legs than 3 x dice 121 241 69 100 min,% ' . 3 X dla and longer 241 ... 100 B Less than 3 x dlas 121 212 69 95 - 3 x dla and longer ... 212 ... 95 • • C All No hardness required ' 4 As measured anywhere7. Dimensions on the surface or through the cross section. B Also bolts with drilled or undersize heads.These sizes and bolts with modified 7.1 Unless otherwise specified, threads shall be the Coarse heads shall meet the minimum and maximum hardness as hardness is the only requirement. Thread Series as specified in the latest issue of ASME B 1.1, ' and shall have a.Class 2A tolerance. .• • TABLE 3 Tensile Requirements for Full-Size Botts and Studs 7.2 Unless otherwise specified,.Grade.A bolts shall be hex bolts with dimensions as given in the latest issue. of ASME Bolt Threads Stress Tensile Strength,IbfB B 18.2.1: Unless otherwise specified, Grade B bolts shall be Size, per inch Ar ," Grade .Grade B heavy hex bolts with dimensions as given in the.latest issue of in. in.' A,min° min° max° ASME B 18.2.1. 1/4 20 '0.0318 ' 1 900 ' 1 900 3 180 • 7.3. Unless otherwise specified, bolts and studs.to be used V16 18 0.0524 3 100 3 100 5 240 with nuts or tapped holes which have been tapped oversize;in 14 16 0.0775 . 4 650 4 650 7 750 . accordance with:.Specification A 563, shall have Class 2A '/,6 14 0.1063 6 350 6 350 10 630 threads before hot-dip or mechanically deposited zinc'coating. 1/2 ' ' 13 0.1419 8 500 8 500 14,190 After zinc coating the maximum limit of pitch and Major me 12 0.1 s2 11 000 11 000 1 B 200 diameter shall not exceed the Class 2A maximum limit by more ' 11 0.228 13 550 13 550 22 600 3/4 10 0,334 20 050 20 050 33 400 than the following amounts: ' 9 0.462 27 700 27 700 46 200 . Diameter,in. Oversize Limit,in.(mm)A. .. • 1/4 0.016 • 1 8 0.606 36 350 36 350 60 600 5/i6,%. 0.017 1% 7 0.763 45 800 45 800 76 300 7/ia,1/2 0.018 1% 7 0.969 58 150 58 150 96 900 °As to 9/4,,incl0.020 1% 6 1.155 69 300 69 300 115 500 7,fe 0.022 1.0 to1V4,incl 0.024 11/2 6 1.405 84 300 84 300 140 500 . -0,4 ,11/2 0.027 13 6 1.90 114 000 114 000 190 000 , VA to 4.0,incl 0.050 2 41/2 2.50 150 000 '150 000 250 000 21/4 41 3.25 ' 195 000 195, 000 325 000 A These values are.the same as the overlapping required for zinc-coated nuts in i Specification A 563. • 21/2 4 4.00 240 000 240 000 400 000 7.4 The gaging limit for bolts and studs shall be verified • 23/4 4 4.93 295'800 ' 295 800 493 000 3 4 5.97 358 200 358 200 597 000 during manufacture or,use, by assembly of a nut tapped.as 31/4 ' 4 7.10 426 000 426 000 710 000 nearly as practical to the amount oversize shown above.In case 3Y2 4 8.33 499 800 499 800 833 000 of dispute, a calibrated thread ring gage of that same size 3314 4 9.66• . 579 600 579 600 966 000 (Class X tolerance, gage tolerance plus)shall be used.Assem- . 4 4. 11.08 664 800 664 60o 1 108 000 - bly of the gage, or the nut described'above, Must be possible • t A Area calculated from the equation:. with hand effort following application of light machine oil to - A6-0.7854(D-(0.9743/n)? prevent galling and damage to the gage. These inspections, where: when performed to resolve disputes, shall be performed at the As = stress area, • ' ' -s D = nominal diameter of bolt,and frequency and quality described in Table 5. n = threads per inch. • i . eilbf=4.448 N. • • °Based on 60 ksl(414 MPa). • TABLE 5 Sample Sizes and Acceptance Numbers for Inspection DBased on.60-100 ksi(414-690 Mia). of Hot-Dip or Mechanically Deposited Zinc-Coated Threads Lot Size Sample Size." Acceptance Number" shown in Table 4 for information. In the event of conflict 2 to 90 13 1 Specification A 36/A 36M shall control. 91 to 150 '20 2 6.6 In the event that bolts are tested by both full size and by 151 to 280 32. 3. 281 to 500 50 5 machine test specimen methods, the full-size test shall govern 501 to 1 200 80 7 if a controversy between the two methods exists. 1 201 to 3 200 • ' 125 . . 10 6.7 For bolts and studs on which both hardness and tension 3 201 to 10 000 200 14 �1 10 001 and over • 315 21 tests are performed, acceptance based on tensile requirements A •, < precedence in the event that there is controversyover Sample sizes of acceptance numbers are extrapted from Single Sampletg shall take Plan for Normal Inspection,'Table IIA,MIL-STD-105. ' low readings of hardness tests. a Inspect all bolts In the lot If the lot size is less than the sample size. i { '7 .A111' A 307-04d1 8. Number of Tests and Retests cation that are requested by the purchaser's representative shall 8.1 The requirements of this specification shall be met in be made before shipment, and shall be conducted as not to interfere unnecessarily with the operation of the works. continuous mass production for stock, and the manufacturer shall make sample inspections to ensure that the product 11. Responsibility conforms to the specified requirements. Additional tests of individual shipments of material are not ordinarily contem- 11.1 The party responsible for the fastener shall be the plated.Individual heats of steel are not identified in the finished organization that supplies the fastener to the purchaser. product. 8.2 When specified in the order, the manufacturer shall 12. Rejection and Rehearing furnish a test report certified to be the last completed set of 12.1 Disposition of nonconforming lots shall be in accor- mechanical tests for each stock size in each shipment. dance with Guide F 1470, specifically sections on disposition 8.3 When additional tests are specified on the purchase of nonconforming lots,suppliers option,and purchasers option. order, a lot,for purposes of selecting test samples,shall consist of all material offered for inspection at one time that has the 13. Product Marking following common characteristics: 8:3.1 One type of item, 13.1 Grades A and B Bolts and Studs: 8.3.2 One nominal size, and 13.1.1 Bolt heads and one end of studs shall be marked with • 8.3.3 One nominal length of bolts and studs. a unique identifier by the manufacturer to identify the menu- 8.4 From each lot, the number of tests for each requirement facturer or private label distributor, as appropriate.Additional shall be as follows: marking required by the manufacturer for his own use shall be Number of Pieces in Lot Number of Samples at the option of the manufacturer. 800 and under t 13.1.2 In addition to the requirements of 13.1,all bolt heads, 801 to S 000 2 one end of studs 3/s in. and larger,and whenever feasible studs Over • 2z o000 8 eio 022 000 a less than 3/s in. shall be marked with a grade marking as 8.5 If any machined test specimen shows defective machin- follows: ing it shall be discarded and another specimen substituted. Grade Marking A 307A 8.6 Should any sample fail to meet the requirements of a B 307B specified test,double the number of samples from the same lot 13.1.3 All markings shall be located on the top of the bolt shall be tested,in which case all of the additional samples shall head or stud end and shall be raised or depressed at the option meet the specification. of the manufacturer. 9. Test Methods 13.2 Grade C Anchor Bolts: 9.1 Grades A and B bolts and studs shall be tested in 13.2.1 The end of Grade C anchor bolts intended to project accordance with Test Methods F 606. from the concrete shall be color coded green. 9.2 Grade C nonheaded anchor bolts shall have machined 13.2.2 When permanent marking of manufacturer's identi- specimen tension tests made on the bolt body or on the bar fication and grade identification is required, Supplementary stock used for making the anchor bolts. Tests on finished Requirements S2 and S3 shall be specified. anchor bolts shall be made in accordance with Test Methods 13.3 Grade and manufacturer's or private label distributor's F 606 and tests on bar stock in accordance with Specification identification shall be separate and distinct. The two identifi- A 36/A 36M and Test Methods and Definitions A 370. cations shall preferably be in different locations and, when on 9.3 Standard square and hex head bolts only shall be tested the same level, shall be separated by.at least two spaces. by the wedge tension method except as noted in 6.4. Fracture shall be in the body or threads of the bolt without any fracture 14. Packaging and Package Marking at the junction of the head and body. Other headed bolts shall 14.1 Packaging: be tested by the axial tension method. 14.1.1 Unless otherwise specified, packaging shall be in 9.4 Speed of testing as determined with a free running accordance with Practice D 3951. crosshead shall be a maximum of 1 in,/min(25.4 mm/min)for , 14.1.2 When special packaging requirements are required, the tensile strength tests of bolts. they shall be defined at the time of the inquiry and order. • 10. Inspection 14.2 Package Marking: 14.2.1 Each shipping unit shall include or be plainly marked 10.1 If the inspection described in 10.2 is required by the with the following information: �. purchaser it shall be specified in the inquiry,order,or contract. 14.2.1.1 ASTM designation and grade, 10.2 The inspector representing the purchaser shall have free entry to all parts of the manufacturer's works that concern 14.2.1.2 Size, . the manufacture of the material ordered. The manufacturer 14.2.1.3 Name and brand or trademark of the manufacturer, shall afford the inspector all reasonable facilities to satisfy him 14.2.1.4 Number of pieces, • . . that the material is being furnished in accordance with this 14.2.1.5 Purchase order number, ; specification. All tests and inspections required by the specifi- 14.2.1.6 Country of origin. • 8 441111 4)t' A 307-04" 1 15. Keywords 15.1 bolts; carbon steel; steel; studs SUPPLEMENTARY REQUIREMENTS . • The following supplementary requirement shall apply only when specified in the purchase order or contract: • • t , Si. Bolts Suitable for Welding • carbon equivalent(CE)not exceeding 0.55 when calculated as S1.1 The material described in this section is intended for follows: welding. This supplemental section, by additional chemical CE_ % C+ composition restrictions and by a carbon equivalent formula, %Mn %Cu %Ni %Cr %Mo_ %V provides assurance of weldability by chemical composition �+ 40 +20 +10 -50 10 control. S1.2 Welding technique is of fundamental importance when . 51.6--Analysis Reports—If requested on the•order or con- bolts produced to this supplementary section are welded. It is tract, the chemical composition of each heat of steel used and presupposed that suitable welding procedures for the steel the calculated carbon equivalent for each heat shall be reported being welded and the intended service will be selected. to the purchaser. S1.3 All of the requirements of this supplemental section 81.7 Product (Check) Verification Analysis--Chemical apply in addition to all of the chemical, mechanical,and other analyses when made by the purchaser or a representative on requirements of the base specification, Specification A 307 for bolts from each heat of steel, shall not exceed the values Grade B. specified in S1.5.2 by more than the following amounts: • S1.4 Because of the embrittling effects of welding tempera- tures on cold-forged steel, this supplemental section is limited Carbon +0.03 to hot-forged bolts, or, if not forged, then to bolts produced Manganese +0.06 from hot-rolled bars without forging or threaded bars, bars Sulfur us. +0.008 �g Sulfur • +0.008 studs, or stud bolts produced from hot-rolled bars without Sifloon +0-05 forging.Cold-forged bolts,or cold-drawn threaded bars,if they are given a thermal treatment by heating to a temperature of not S2. Permanent Manufacturer's Identification less than 1500°F (815°C) and air-cooled are also suitable. S2.1 The end of the anchor bolt intended to project from the S1.5 Chemical Requirements: concrete shall be steel die stamped with the manufacturer's S1.5.1 Heat Chemical Analysis—Material conforming to identification. the following additional analysis limitations shall be used to manufacture the product described in this supplementary Nara —For marking small sizes, customarily less than Vs in., consult the anchor bolt manufacturer for the minimum size capable of being requirement. marked. Carbon0.30%,max Manganese 1.00%,max S3. Permanent Grade Identification Phosphorus 0.04%,max Sulfur 0.05%,max S3.1 The end of the anchor bolt intended to project from the Silicon 0.59%,max concrete shall be steel die stamped with the Grade identifica- S1.5.2 Carbon Equivalent (Source—Specification A 7061 tion "307C". A 706M)—In addition to the heat chemical analysis require- S3.2 The requirements in S2.1 for marking small sizes shall ments in S1.5.1,the heat analysis shall be such as to provide a also apply to Supplementary Requirement S3. { 5 � 9 Pipe Clamps Fig. 23 - Hanger for CPVC Plastic Pipe III Ilin. Double Fastener Strap (Cooper B-Line B3182) V�M c Cl us LISTED Size Range: 3/4" (2omm)thru 3" (80mm)CPVC pipe Material: Pre-Galvanized Steel Function: Intended to perform as a hanger to support CPVC piping used in automatic fire sprinkler systems. Fig.23 can be installed on the top, bottom or side of a beam. Approvals: Underwriters Laboratories Listed in the USA(UL) and Canada(cUL)sizes 3/4" (20mm)thru 2" (50mm)to support fire sprinkler piping. May be installed in wood using fasteners supplied with product,or into minimum 20 gauge(0.9mm)steel using(2)1/4"x 1"tek type screw. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features: Fig.23 incorporates features which protect the pipe ,,, a and ease installation.The flared edge design protects the CPVC pipe from any rough surface. It also incorporates snap restrainers allowing easier and faster installation. Easily attaches to the building B A structure using the two UL Listed hex head self threading screws* c furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools(such as a hammer)are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish: Pre-Galvanized dr- Order rOrder By: Figure number and pipe size } *Hardened hex head self threading screw is furnished with thek414," product and is the minimum fastener size acceptable. ig . , __ t CPVC Max.Hanger Fastener Hex Approx. 11. Pipe Size A B C Spacing Head Size Wt./100 es 6 Part No. in. (mm) in. (mm) in. (mm) in. (mm) Ft (m) in. (mm) Lbs. (kg) 3 23-3/4 3/4" (20) 31/8" (79.4) 19/16" (39.7) 13/16" (30.2) 51/2 (1.67) 5/16" (7.9) 9 (4.1) 23-1 1" (25) 33/8" (85.7) 111/16" 42.9) 13/16" (30.2) 6 (1,83) 5/16" (7.9) 9 (4.1) co 23-11/4 11/4' (32) 43/16" (106.4) 23/32" (53.1) 13/16" (30.2) 61/2 (1.98) 5/16" (7.9) 11 (5.0) 23-11/2 11/2" (40) 47/16" (112.7) 27/32" (56.3) 13/16" (30.2) 7 (2.13) 5/16" (7.9) 12 (5.4) 23-2 2" (50) 47/8" (123.8) 27/16" (61.9) 13/16" (30.2) 8 (2.44) 5/16" (7.9) 15 (6.8) 23-21/2 , 21/2" (65) 53/8" (136.5) 211/16" (68.3) 13/16" (30.2) Consult Factory 5/16' (7.9) 22 (10.0) 23-3 3" (80) 6' (152.4) 3" (76.2) 13/16" (30.2) Consult Factory 5/16" (7.9) 25 (11.3) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. 94 Pipe Clamps Fig. 24 - Hanger for CPVC Plastic Pipe Double Fastener Strap Side Mounted (Cooper B-Line B3183) cOus LISTED Size Range: 3/4" (20mm)thru 2" (50mm)CPVC pipe Material: Pre-Galvanized Steel Function: Intended to perform as a hanger to support CPVC piping used in M h - automatic fire sprinkler systems. Can be installed on the top or on the bottom of a beam. Approvals: Underwriters Laboratories Listed in the USA(UL) and Canada(cUL)to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge(0.912mm)steel i using (2) 1/4" x 1"tek type screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features: Fig.24 incorporates features which protect the pipe and i'' ease installation.The flared edge design protects the CPVC pipe from any rough surface. Easily attaches to the building structure using the two 11 UL Listed hex head self threading screws*furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a hammer) are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. B Finish: Pre-Galvanized B�� Order By: Figure number and pipe size A Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. J I ,1/44411 CPVC Max.Hanger Fastener Hex Approx. Pipe Size A B C Spacing Head Size Wt./100 Part No. in. (mm) in. (mm) in. (mm) in. (mm) Ft. (m) in. (mm) Lbs. (kg) 24-3/4 3/4" (20) 25/16" (58.7) 15/32" (27.8) 13/16" (30.2) 51/2 (1.67) 5/16" (7.9) 9 (4.1) 24-1 ®M' 25/8" 66.7 15/16" M, 13/16" 30.2 6 1,83 5/16" 7.9 9 4.1 24-11/4 11/4" (32) 3" (76.2) 11/2" (38.1 13/16" (30.2) 61/2 (1.98) 5/16" 7.9) 11 (5.0) 24-11/2 11/2" (40) 31/4" (82.5) 15/8" (42.3) 13/16" (30.2) 7 (2.13) 5/16" (7.9) 12 (5.4) 24-2 2" (50) 311/16" (93.7) 127/32" (43.6) 13/16" (30.2) 8 (2.44) 5/16" (7.9) 15 (6.8) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. IIIIIIIIIIIIIIIIIIIIIIIIICIIIIIIIIIIIIIIIIIIIIM COOPER B-Line Pipe Clamps Fig. 28 - "Stand-Off" Hanger & Restrainer for CPVC Plastic Pipe Size Range:—3/4"(20mmCC)US through 2" (50mm) LISTED Material: Material:—Steel, Pre-Galvanized MrciirA Function:—Designed to be used as a hanger and restrainer for CPVC piping where / 1116-.14114 the "stand-off" design will ease installation by eliminating the need for wood blocking. Features: •Flared edge design protects CPVC pipe from any rough or abrasive surfaces. • Unique twist and lock design holds pipe firmly in place and allows retrofit type of installation. 1 t •The"Stand-Off"design eliminates the need for wood block extension. A •Can be installed on horizontal or vertical piping regardless of mounting surface orientation. B •Attaches easily to wood structure with two hex head self-threading screws furnished with c product. •Installs easily using rechargeable electrical driver with 5/16" (7.9mm)extension socket eliminating impact tool damage to pipe. •Attaches easily to steel, minimum 18 gauge (1.024mm)with (2) 1/4"x 1"tek type self drilling tapping screws. .- •UL Listed as a hanger and a restrainer for fire sprinkler piping. i= Approvals:—Underwriters Laboratory Listed in the USA(UL)and Canada(cUL)to support automatic fire sprinkler systems. May be installed into wood using fasteners supplied with product, or into minimum 18 gauge steel using (2) 1/4" x 1"tek type screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Fig. 28 satisfies the UL vertical restraint requirement where needed. UL Listed as a hanger and vertical restraint when installed on 3/s" (9.5mm) composite wood material. Use two Fig. 27B Speed Nuts when used as a hanger and restraint. Use one Fig. 27B Speed Nut on the upper `' installed screw when used as a hanger only. Order by:—Figure number and pipe size. Pat. #7,455,268, Pat.#7,832,248 'Sk ''''' \ 1 , - 1 ,................4, ,.„ /1/44 _ :� Fi ) i g.27B Fig.27B I 1 (1) Required (2) Required Fig. v High Side of (13 Hanger . Application 1��•' 74f- :a l - , Hanger Application Hanger and Restraint '-,-- -IJ. „ Application y u% Pipe Size A B C Approx.Wt./100 Part No. in. (mm) in. (mm) in. (mm) in. (mm) lbs. (kg) 28-3/4 3/4" (20) 31/32' (77.0) 2" (50.8) 31/2" (88.9) 18 (8.1) 28-1 1' (25) 35/16" (84.1) 23/16" (55.6) 31/2" (88.9) 21 (9.5) 28-11/4 11/4" (32) 35/8" (92.1) 23/8" (60.3) 31/2" (88.9) 23 (10.4) 28-11/2 11/2" (40) 4" (101.6) 21/2" (63.5) 31/2" (88.9) 31 (14.0) 28-2 2" (50) 41/2" (114.3) 211/16" (68.3) 35/8" (92.1) 34 (15.4) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. 98 Seismic Bracing Fig.4L- Longitudinal "In-Line"Sway Brace Attachment flic0 US 41> Size Range: 2"(50mm)through 8" (200mm)ips. LISTED Material: Steel ` St Screw&Hardware �� Function: For bracing pipe against sway and seismic disturbance. included e �!.� �y�/ri Approvals: Underwriters Laboratories Listed in the USA(UL)and �� Canada(cUL)21/2"(65mm)through 8"(200mm)pipe.Approved by Factory t Mutual Engineering(FM),2"(50mm)through 8"(200mm)pipe. Installation Instructions: Fig.4L is the"braced pipe"attachment component of a longitudinal sway brace assembly. It is intended to be D A )1 combined with the"bracing pipe"and Cooper B-LineITOLCO structural attachment component to form a complete bracing assembly.NFPA 13 and/or m OSHPD guidelines should be followed. e i To Install: Place the Fig.4L over the pipe to be braced and tighten m bolts.Then engage"bracing pipe" into jaw opening and tighten set screw c j 0 until head snaps off.Jaw attachment can pivot for adjustment to proper kl E brace angle. N Finish: Plain.Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number,pipe size and finish. .1 4001/.\ '! . -,,,„ - : '_.'k° ~• 4, (yam Longitudinal 4-Way Riser Brace l ,�� Brace (plan view) �•• Pipe Max.Rec.Load *Max.Design Load Approx. Part Size A C D Bolt Size (cULuc) (FM) Wt./100 No. in. (mm) in. (mm) in. (mm) in. (mm) lbs. (kN) lbs. (kN) lbs. (kg) =® (50) 53/8" (136.5) 21/16" (52.4) 21/16' (52.4) 1/2"-13 2015 (8.96) -- (--) 247 (112.0) 4L-21/2 ® (65) 67/16" (163.5) 21/2" (63.5) 23/4" (69.8) 1/2"-13 2015 (8.96) 3000 (13.34) 253 (114.7) 4L-3 ® (80) 7" (177.8) 23/4" (69.8) 31/16" (77.8) 1/2"-13 2015 (8.96) 1550 (6.89) 268 (121.5) 41-4 4" (100) 81/2 (215.9) 33/8 (85.7) 311/16" (93.7) 1/2"-13 2015 (8.96) 1550 (6.89) 348 (157.8) 4L-5 5" (125) 93/4" (247.6) 37/8" (98.4) 43/8" (111.1) 1/2"-13 2015 (8.96) 1450 (6.45) 380 (172.3) 4L-6 6" (150) 111/2" (292.1) 5" (127.0) 51/8" (130.2) 1/2"-13 2015 (8.96) 1450 (6.45) 640 (290.3)_ 4L-8 8" (200) 131/4" (336.5) 55/8" (142.8) 55/8" (142.9) 1/2"-13 2015 (8.96) 1450 (6.45) 728 (330.2) Pipe Max.Rec.Load *Max.Design Load(FM) Part Size (cULuc) 30°-44° 45°-59° 60°-74° 75°-90° No. in. (mm) lbs./(kN) lbs. (kN) lbs. (kg) *The loads listed are axial loads on the brace. 4L-2 ® (50) 2015(8.96) The horizontal load capacity, H,of the ®® brace is: H=F x sin?,where?the installation (65) 2015(8.96) 1030(4.58) 1180(5.24) 1420(6.31) 1590(7.07) angle measured from the vertical. 4L-3 3" (80) 2015(8.96) 1030(4.58) 1180(5.24) 1420(6.31) 1590(7.07) FM approved when used with 1", 11/4", 11/2" or 4L-4 4" 2" Sch.40 brace pipe. (100) 2015(8.96) 530(2.36) 730(3.25) 890(3.96) 990(4.40) 41-5 5" (125) 2015(8.96) 530(2.36) 730(3.25) 890(3.96) 990(4.40) 41-6 6 (150) 2015(8.96) 530(2.36) 730(3.25) 890(3.96) 990(4.40) 4L-8 8" (200) 2015(8.96) 490(2.18) 680(3.02) 830(3.69) 930(4.13) Cooper B-Line,Inc.'s("Cooper B-Line")seismic bracing components are designed to be compatible only with other Cooper B-Line bracing components,resulting in a listed seismic bracing assembly.Cooper-B-Line's warranty for seismic bracing components will be the warranty provided in Cooper B-Line's standard terms and conditions of sale made available by Cooper B-Line,except that,in addition to the other exclusions from Cooper B-Line's warranty,Cooper B-line makes no warranty relating to Cooper B-Line's seismic bracing components that are combined with products not provided by Cooper B-Line. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. 169 OO ER CB-Line ®TOLCO' Fig. 980 - Universal Swivel Sway Brace Attachment cOu LISTED APPROVED Size Range — One size fits bracing pipe 1"thru 2", TOLCO 12 gauge channel, and all structural steel up to 1/4" thick. Component of State of California OSHPD Approved Material — Carbon Steel Seismic Restraints System Function — Multi-functional attachment to structure or braced pipe fit- ting. Features — This product's design incorporates a concentric attachment OR opening which is critical to the performance of structural seismic con- %MO nections. NFPA 13 (2010) 9.3.5.8.4 indicates clearly that fastener table load values are based only on concentric loading. Mounts to any sur- face angle. Break off bolt head assures verification of proper installation. Installation — The Fig.980 is the structural or transitional attach- IIIIIH ment component of a longitudinal or lateral sway brace assembly. It is ' intended to be combined with the "bracing pipe" and TOLCO "braced ill pipe" attachment, Fig. 1000, 1001, 2002, 4L, 4A or 4B to form a com plete bracing assembly. NFPA 13 and/or OSHPD guidelines should be I followed. To Install — Place the Fig. 980 onto the "bracing pipe". Tighten the set bolt until set bolt head breaks off.Attachment can pivot for adjustment IIIIIIIII ,to proper brace angle. A b Approvals — Underwriters Laboratories Listed in the USA(UL)and Canada(cUL). Approved by Factory Mutual Engineering (FM). Included 8 in our Seismic Restraints Catalog approved by the State of California Officeof Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Note — The Fig. 980 Swivel Attachment and the Fig. 1001, Fig. 1000, 7.7T---, _._ `; Fig. 2002, Fig. 4A, Fig. 4B or Fig. 4L Pipe Clamp make up a sway brace •' system of UL Listed attachments and bracing materials which satisfies ".;,, % the requirements of Underwriters' Laboratories and the National Fire " Protection Association (NFPA) r -, $ Finish — Plain ( ' ,;� };.: rrr.. iit.. 74:a Note — Available in Electro Galvanized finish. a . .�"' Order By — Figure number and finish. r, { Pat. #6,273,372, Pat. #6,517,030, Pat. #6,953,174, -.; . I ' Pat. #6,708,930, Pat. #7,191,987, Pat. #7441 730 - t4" r- Pat. #7,669,806 Dimensions•Weights *Available with hole sizes to accommodate up to 3/4"fastener. Max.Design Max.Design Consult factory. A B H* Load Lbs. Load Lbs.** Approx. •*The loads listed are axial loads on the brace.The horizontal load (cULus) (FM) Wt./100 capacity, H,of the brace is:H=F x sin 0,where 0 is the installation angle measured from the vertical. 51/4 17/817/32 2765 2800 132 Cooper B-Line, Inc.'s ("Cooper B-Line") seismic bracing components are designed to be compatible only with other Cooper B-Line bracing components, resulting in a listed seismic bracing assembly. Cooper B-Line's warranty for seismic bracing components will be the warranty provided in Cooper B-Line's standard terms and conditions of sale made available by Cooper B-Line,except that,in addition to the other exclusions from Cooper B-Line's warranty,Cooper B-Line makes no warranty relating to Cooper B-Line's seismic bracing components that are combined with products not provided by Cooper B-Line. COOPER B-LINE 1375 Sampson Ave•Corona,CA 92879•800.786.5266•FAX:951.737.0330 www.tolco.com 1011 COOPER B-Line V TOLCO www.tolco.com NIBCO Revision 7/15/2011 Fig. 1000 - "Fast Clamp" Sway Brace Attachment Caliornlifornia OSHPD pDponent of pAppte of proved Seismic Restraints System Size Range — Pipe size to be braced: 1" thru 6" Schedule ..---- 10 thru 40 IPS.* Pipe size used for bracing: 1" and 11/4" Schedule 40 ' --~-- c0 VS tam IPS. Additionally(UL) approved for use with Allied Dyna Flow sprinkler m �'� \ pipe up to 2" as a restraint device. Maximum horizontal design load �� is 655 lbs. Torque requirement is 6-8 ft. lbs. I\ Material — Carbon Steel i Function — For bracing pipe against sway and seismic disturbance. \`� \ Features — Field adjustable, making critical pre-engineering of \ ' bracing pipe unnecessary. Unique design requires no threading of bracing pipe. Can be used as a component of a 4-way riser brace. Can be used as longitudinal brace with Fig. 907. Steel leaf spring f K% insert provided to assure installer and inspector necessary minimum torque has been achieved. — 1/' /+ r Installation — The Fig. 1000 is the "braced pipe" attachment j component of a lateral sway brace assembly. It is intended to be �_ combined with the "bracing pipe" and TOLCO structural attachment i . _f component, Fig. 980, 910 or 909 to form a complete bracing assem- /, bly. Follow NFPA 13 and/or OSHPD guidelines. .,. To Install — Place the Fig. 1000 over the pipe to be braced, insert bracing pipe through opening leaving a minimum of 1" extension. Brace pipe can be installed on top or bottom of pipe to be braced. Tighten hex nuts until leaf spring is flat. It is recommended that the brace angle be adjusted before hex nuts are fully tightened. UL Listed Design Load Approvals — Underwriters Laboratories Listed in the USA(UL) 1" thru 4" pipe size — 2015 lbs. and Canada (cUL). Approved by Factory Mutual Engineering (FM). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development FM Approved Design Loads (OSHPD). For additional load, spacing and placement information 1" - 21/2" - 600 lbs. relating to OSHPD projects, please refer to the TOLCO Seismic 3" - 4" - 700 lbs. Restraint Systems Guidelines. Application Note — Position Fast Clamp and tighten two hex nuts until leaf spring flattens. A minimum of 1" pipe extension beyond the Fig. 1000 is recommended. Finish — Plain ----,, Note — Available in Electro-Galvanized and HDG finish or Stainless { Steel materials. �,,'� +. Order By — Order first by pipe size to be braced, followed by pipe /f size used for bracing, figure number and finish. . / /J. �� 0r TOLCO®brand bracing components are desgined to be compatible ONLY with 1 other TOLCO®brand bracing components,resulting in a Listed seismic brac- � � ing assembly. DISCLAIMER — NIBCO does NOT warrant against the failure of TOLCO®brand bracing components, in the instance that such TOLCO®brand Lateral Brace bracing components are used in combination with products, parts or systemsy which are not manufactured or sold under the TOLCO®brand. NIBCO shall NOT WA be liable under any circumstance for any direct or indirect, incidental or conse- quential damages of any kind, including but not limited to loss of business or profit,where non-TOLCO brand bracing components have been, or are used. OFFICE/MANUFACTURING FACILITY•1375 SAMPSON AVE.•CORONA,CA 92879•PH. 951.737.5599•FAX: 951.737.0330 CUSTOMER SERVICE•800.786.5266111 www.fo/co.com Seismic Bracing Fig. 1001 - Sway Brace Attachment ®TOLCO Size Range: Pipe size to be braced: 21/2" (65mm)thru 8" (200mm) IPS. C 0 US * Pipe size used for bracing: 1" (25mm)and 11/4" (32mm)Schedule 40 IPS. Material: Steel LISTED Function: For bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace system: Fig. 1001 is used in conjunction with a Fig. 900 Series fitting and joined together with bracing pipe per NFPA 13,forming a complete sway brace assembly. Features: Can be used to brace schedules 7 through 40 IPS. Field adjustable, making critical pre-engineering of bracing pipe length unnecessary. Unique design requires no threading of bracing �� pipe. Comes assembled and ready for installation. Fig. 1001 has built-in visual verification of correct installation. See installation note below. Installation Note: Position Fig. 1001 over the pipe to be braced Set Bolts and tighten two hex head cone point set bolts until heads bottom c�` Included out.A minimum of 1" (25mm) pipe extension is recommended. Brace pipe \�� can be installed on top or bottom of pipe to be braced. Approvals: Underwriters Laboratories Listed in the USA(UL) and Canada(cUL). UL Listed Design Load For FM Approval information refer to page 65. Sch.7 - 1600 lbs.(7.11kN) Finish: Plain. Contact Cooper B-Line for alternative finishes and materials. Sch.10&40 w/1"(25mm)Brace Pipe Order By: Order by figure number, pipe size to be braced, followed by pipe 2015 lbs.(8.96kN) size used for bracing (1" (25mm)or 11/4" (32mm)) , and finish. Sch.10&40 w/11/4"(32mm)Brace Pipe Important Note: Fig. 1001 is precision manufactured to perform its 2765 lbs.(12.30kN) function as a critical component of a complete bracing assembly. To ensure performance, the UL Listing requires that Fig. 1001 must be used only with other Cooper B-LineiTOLCO bracing products. Pipe Part Number&Approx.Wt/100 Design .A Size 1"(24mm)Brace Pipe 11/4"(32mm)Brace Pipe Load in. (mm) Lbs. (kg) Lbs. (kg) ® (65) 1001-21/2 X 1 138.6 (62.8) 1001-21/2 X 11/4 160.4 (72.7) UL '+.. 111 (80) 1001-3 X 1 147.2 (66.7) 1001-3 X 11/4 168.7 (76,5) UL 4" (100) 1001-4 X 1 160.9 (73.0) 1001-4 X 11/4 182.4 (82.7) UL 6" (150) 1001-6 X 1 190.0 (86.2) 1001-6 X 11/4 211.4 (95.9) UL 8" (200) 1001-8 X 1 217.4 (98.6) 1001-8 X 11/4 238.8 (108.3) UL "See load ratings in UL Listed Design Load chart. The loads listed are axial loads on the brace.The horizontal load capacity, H,of the brace is: H= F x sin ?,where? is the installation angle measured from the vertical. il _....,,i iv i,`� IF El -- i All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. 00 COOPER B-Line Seismic Bracing Fig. 1001 - Sway Brace Attachment ®TOLCO Size Range: Pipe size to be braced:21/2" (65mm)thru 8" (200mm) IPS. II:* * Pipe size used for bracing: 1" (25mm)and 11/4" (32mm)Schedule 40 IPS. APPROVED Material: Steel Function: For bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace system: Fig. 1001 is used in conjunction with a Fig.900 Series fitting and joined together with bracing pipe per NFPA 13,forming a complete sway brace assembly. Features: Can be used to brace schedules 7 through 40 IPS. ; Field adjustable, making critical pre-engineering of bracing pipe C1 length unnecessary. Unique design requires no threading of bracing pipe. Can be used as a component of a four-way riser brace. Comes assembled and ready for installation. Fig. 1001 has built-in visual verification of correct installation. See installation note below. Set Bolts Included Installation Note: Position Fig. 1001 over the pipe to be braced • and tighten two hex head cone point set bolts until heads bottom out.A minimum of 1" (25mm) pipe extension is recommended. Brace pipe can be installed on top or bottom of pipe to be braced. Approvals: Approved by Factory Mutual Engineering(FM). For UL Listed information refer to page 64. FM Approved Design Loads* Finish: Plain. Contact Cooper B-Line for alternative finishes and materials. 21/2"(65mm)pipe size-1600 lbs.(7.11kN) Order By: Order by figure number, pipe size to be braced, followed by pipe 3"(75mm)to 4"(100mm)pipe size-1700 lbs.(7.56kN) size used for bracing(1" (25mm)or 11/4" (32mm)) , and finish. 5"(125mm)to 8"(2oomm)pipe size-1033 lbs.(4.59kN) Important Note: Fig. 1001 is precision manufactured to perform its function as a critical component of a complete bracing assembly. To ensure performance,the FM Approval requires that Fig. 1001 must be used only with other Cooper B-LineiTOLCO bracing products. Designed to meet or exceed requirements of FM DS 2-8. 7 a Pipe Part Number&Approx.Wt./100 Design Size 1"(24mm)Brace Pipe 11/4"(32mm)Brace Pipe Load , ( in. (mm) Lbs. (kg) Lbs. (kg) ** r,titt ® (65) 1001-21/2 X 1 138.6 (62.8) 1001-21/2 X 11/4 160.4 (72.7) FM ...,., ® (80) 1001-3 X 1 147.2 (66.7) 1001-3 X 11/4 168.7 (76,5) FM Lae 4" (100) 1001-4 X 1 160.9 (73.0) 1001-4 X 11/4 182.4 (82.7) FM 6" (150) 1001-6 X 1 190.0 (86.2) 1001-6 X 11/4 211.4 (95.9) FM 8" (200) 1001-8 X 1 217.4 (98.6) 1001-8 X 11/4 238.8 (108.3) FM **See load ratings in FM Approved Design Load chart. * The loads listed are axial loads on the brace.The horizontal load capacity, H,of the brace is: H=F x sin?,where? is the installation angle measured from the vertical. FM Approved design loads are based on ASD design method. i c � '111 J ._iii°.- All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. 00 COOPER B-Line nOCOd •"!,-.4''s SAMMYS `r"' WOOD • 1/4"Rod• Vertical Mount Bar quantity ioi except as toted with this marking I♦J Use#14 Nut Driver(Item#100) • Bar quantity 50 Item # Model Rod Size Shk Dia Shk Lgth 20 GST.750 1/4-20 1/4 3/4 1141l1cm 01001 21 GST 100 1/4-20 1/4 1 22 GST 200 1/4-20 1/4 2 23 GST 300 1/4-20 1/4 3 24• GST 600 1/4-20 1/4 6 See page 13 for Stainless Steel WOOD•3/8"Rod• Vertical Mount Note:Screws less than 2"in Use#14 Nut Driver(Item#100) length will be plated yellow. Greater than 2"are clear FM Test UL Test UL/FM zinc per ASTMB6331I1 Item# Model Rod Size Shk Dia Shk Lgth Load,lb. Load,lb. Pipe Size Actual Pullout 10 GST.75 3/8-16 1/4 3/4 5644-6 Ry 11 GST 10 3/8-16 1/4 1 2104-7/16 OSB 670#-3/4"Ry 4:1k.0, 12 GST 20 3/8-16 1/4 2 9404 850# 3/4-2 1/2 1760#-Fr 014(Item 0100) 27 • GST 25-380 3/8-16 3/8 2 1/2 1500# 4 21134-Fr < r 13 GST 30 3/8-16 1/4 3 14754 15004 3/4-4 2060#-Fr 403• GST 40 3/8-16 1/4 4 21804-Fr 14 • GST 60 3/8-16 1/4 6 22304-Fr WOOD • 1t2"Rod• Vertical Mount Use#14SW Nut Driver(Item#101) Item # Model Rod Size Shk Dia Shk Lgth Actual Pullout 8 • GST 2 1/2-13 1/4 2 17604-Fr •ItSW Ahem/1101i 06• GST 2.5-381 1/2-13 3/8 2 1/2 2113#-Ar NMS-the rusx•mut be used for strews wuh In"cab 15• GST 3 1/2-13 1/4 3 22754-Fr 16• GST 4 1/2-13 1/4 4 21804-Fr 17• GST 6 1/2-13 1/4 6 2230#-Fr Installations Not less then 2"nominal width ee Page S for installation instructions. (1 1n") r .e•( c8 Installation w € !M per NFPA 13 c s s .rte 1a ii b s � v 0 TGI Jois Truss eq • Consult truss manufacturer for recommended Installation point. Wood Flooring ( "Special Notes" 1 On"page r•1 I • .-e Wood Joist MI Lower face 01 f s --w Sammy beam or Joist •!• limp Minimum 2"knbedment Into base - - 1� material for NFPA 13 compliance For vertical use. �.�..�_• -f__.. -« N pInstall in center MIR of lower face. Double Sheetrock Ceiling I a„ a 1 r It you don't see cell us at I te=e I 1.888.773.0001 Wood-Sammys 1 1 Note:Must be installed with appropriate nut driver to comply with warranty. 511'(;. .. l-‘,-(-1's, _�..,�, flood s, page , ,nr 11ainJecc Si'ler' SIDEWINDERS WOOD•1/4"Rod•Horizontal Mount Bat quantity 100 except as noted with this marking (•) Usell14SW Nut Driver(Item#101) • Bus quantity 50 Item# Model Rod Size Shk Da Shk Lgth Actual Shear/Pullout i x14s»',hrn,ru , 300 SWG 200 1/4-20 1,4 2 1725#-Fr Now:Screws less than 2"in length WOOD •3/8"Rod•Horizontal Mount will be plated yellow.Greater than Use#14SW Nut Driver(Item#101) 2"are clear zinc per UL Test UL Pipe Actual ASTM86331!! Item # Model Rod Size Shk Dia Shk Lgth Load.lb. Size Shear/Pullout 18 SWG 10 3/8-16 1/4 1 N43stlIlion auu' lk 19 SWG 20 3/8-16 1/4 2 1250s 3 1725#-Fir 26 ♦ SWG 25-380 3/8-16 3/8 2 1/2 1500= 4 2249#- Fir 25 • SWG 30 3/8-16 1/4 3 if fastening through gusset plates.use the SWO 20(see page 5) Installations TGI Joist/Truss _ _ _____ Consult truss manufacturer for recommended Installation point. Sidewinder .-• ' (See-Special Notes ' Floor Joist w ! °^'t°xr I 1 Si ++Sidewinder 3 ' ; .'" F_ J Adil / WOOD INSTALLATION INSTRUCTIONS GST&SWG —See diagram figures 1-4,11-14 on page 1 18 and 19. Not less than 2"nominal width(1 12") (Self drilling&self-tapping into wood) up to 3 12"pipe:not less than 3" nominal width 4"8 5"pipe Step 1: Insert the appropriate nut driver into a 3/8"or 1/2" portable drill: (a) Use#14 for GST for 3/8"and 1/4"rod; (b) Installation use#14SW for SWG, and for GST for 1/2"rod. per NFPA 13 //f) Step 2: Insert the screw into the nut driver.Now you are ready to install the screw. / Step 3: Position drill and begin installation: (a)for installing GST drill should be in a vertical position; (b)for installing li SWG drill should be in a horizontal position at a right angle .. . i5 — Sidewinder to the structural member. Mlnlmum 212"from bottom for - n __ branch lines.Minimum 3"from Step 4: When the nut driver spins freely on the cap of the Tht'ottomformslnllnes.Exceptlon: requirement shall not apply to 2" screw installation is complete. or thicker nailing strips resung al on top of steel beams. IIIA v Step 5: Screw is now ready to receive 1/4", 3/8", 1/2"or metric all thread rod or bolt stock. Eye protection should be worn at all times when install- IL ing this product. Note: Must be installed with appropriate mit driver to comply with warranty. Wood-Sidewinders 5 D EL__'I"• S.W. 72Avenue PORT PORTLAND, ORR 97224 PHONE 503-620-4020 INC. FAX 503-620-1058 FIRE, CCB# 64174 FIRE PROTECTION CONTRACTORS Bulletin 014 Rev. F co •• Reliabld Model F1FR56 Series Quick Response Standard Spray Model F1FR56 Sprinkler Types Standard Upright - Standard Pendent `., ' ` Conventional ' 4 FI Vertical Sidewall . ' } Horizontal Sidewall + Model F1FR56 Recessed Sprinkler Types Standard Pendent/F1/F2/FP Upright Pendent Horizontal Sidewall Model F1FR56 Concealed Sprinkler Types Standard Pendent '' Listing & Approvals 1. Underwriters Laboratories Inc. and Certified for Canada (cULus). 2. Factory Mutual Approvals (FM) Vertical Sidewall Conventional 3. Loss Prevention Council (LPCB, UK) 4. VdS Schadenverhutung GmbH UL Listing Category Sprinklers, Automatic&Open (VNIV) Quick Response Sprinkler Product Description Reliable Models F1FR56 Series Sprinklers are quick re- ' ' sponse sprinklers which combine the durability of a stan- Horizontal Sidewall Recessed dard sprinkler with the attractive low profile of a decorative pendent/F1/F2 sprinkler. The Models F1FR56 Series Recessed automatic sprin- klers utilize a 3.0 mm frangible glass bulb. These sprin- . , klers have demonstrated response times in laboratory tests .)' ,.. k `t- , which are five to ten times faster than standard response y sprinklers. This quick response enables the Model F1FR56 , 'IP,,� Series sprinklers to apply water to a fire much faster than ,�, • standard sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount Recessed Recessed of special fluid hermetically sealed inside a precisely manu Horizontal Sidewall Pendent/FP factured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. At normal temperatures, the glass bulb contains the fluid Application in both the liquid and vapor phases. The vapor phase can Quick response sprinklers are used in fixed fire protec- be seen as a small bubble. As heat is applied, the liquid tion systems: Wet, Dry, Deluge or Preaction. Care must be expands, forcing the bubble smaller and smaller as the liq exercised that the orifice size, temperature rating, deflec uid pressure increases. Continued heating forces the liquid tor style and sprinkler type are in accordance with the lat to push out against the bulb, causing the glass to shatter, est published standards of the National Fire Protection As opening the waterway and allowing the deflector to distrib sociation or the approving Authority Having Jurisdiction. ute the discharging water. Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model F1 FR56 Quick Response Upright, Pendent & Conventional Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Sprinkler Identification NumberNominal Thread Nominal K Factor Sprinkler Approval (SIN) Orifice Size Height Organization US Metric Upright Pendent Standard-Upright(SSU)and pendent Deflectors Marked to Indicate Position 1/2"(15mm) 1/2"NPT(RY) 5.6 80 2.25"(57mm) 1,2,3,4 RA14250) RA1414(1x2) Conventional-Install in Upright or Pendent Position 15mmo) 1/2"NPT(RY) 5.6 80 57mm 3,4 RA1475 (1)cULus listed corrosion resistant(Polyester coated)sprinkler. (2)Polyester coated FM approved sprinkler. a 111 A, ,— _- ..&,..Lii Upright Pendent Conventional Model F1 FR56 Quick Response Recessed Pendent Sprinkler Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Thread K Factor Sprinkler Sprinkler Identification Number Orifice Size US Metric Height (SIN) 1/2"(15mm) 1/2" NPT(R' ) 5.6 80 2.25"(57mm) RA1414 (1) Refer to escutcheon data table for approvals and dimensions. f—2 5/8"DIA [66.7mm] .".-_2 1/4'HOLE DIA HOLE IN CEILING [572mm] 1 15/16'0/A 2 5/16'D/A. [58.7mmJ �- r49.2„,„,, CUP ______-I L ----- rs—=_1— _i, T 1'X 1/2'REDUCER I I I 1"X 1/2"REDUCER TURN COLLAR 4 UNTIL LIGHT AGAINST SPRINKLER WRENCH BOSS \ \ / I\ / iC�ll011 J1 - ilirli___,_LFACE OF FITTING TON CEILING ADJUSTMENT(?) CE/UNG D/MENS/ON _/�� l 1� : lFACE OF F1TTlNG fil , 1/B. - ! 'III i 'III' 70 FACE OF CEILING II! ii A' `\ I�l.' i,�ll , 'DIMENSION[f)Q.: ::/ r3.2mmJ n, 'j1���lj' 1��� 1 ADJUSTMENT J �•,I.I 'A" 2 27/32"DW. 014FGOI ..._�.... [72.2mmJ ••••• 014FCO2 (1)REFER TO Fl&F2 ESCUTCHEON DATA TABLE FOR APPROVALS AND DIMENSIONS. (1)REFER 70 FP ESCUTCHEON DATA TABLE FOR APPROVALS AND DIMENSIONS. Model F1FR56/F1 or F2 Model F1FR56/FP 2. Model Fl FR56 Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal K Factor Sprinkler Sprinkler ApprovalThread Size Orifice US Metric Height Organizations Identification _ Numbers (SIN) /2"(15mm) 1/2" NPT(R1/2) 5.6 8.0 2.25"(57mm) 1,2,3,4 RA1485 15mm 1"NPT(R1/2) 5.6 8.0 2.25"(57mm) 4(1) (1)LPC Approval is for pendent position only. Sprinkler Type Deflector to Ceiling Distance (Min. -Max.) 05111 Upright 4"(102mm) 12"(305mm) Pendent 4"(102mm)- 12"(305mm) Vertical Sidewall Model Fl FR56 Quick Response Horizontal Sidewall Sprinkler Deflector: HSW Installation Wrench: Model D Sprinkler Wrench Installation Data: Horizontal Sidewall Sprinkler Approval Organizations Nominal K Factor Height and Type of Approval Sprinkler Nominal Orifice Thread Size H Identification US Metric Light Hazard Ordinary Numbers (SIN) Hazard 'h"(15mm) 1/2"NPT(R1/2) 5.6 80 2.63"(67mm) 1,2 1 RA1435 4 FACE OF FITTING(1) TO FACE OF CEILING . DIMENSION 1 1/4"MIN. 2 1/4"HOLE DIA. [31.8mm] 1/8" 4"-12" • [57.2mm] [3.2mm] [101.6mm-304.8mm] CEILING TO 1"X 1/2"REDUCER \ DEFLECTOR / _^i Li \\O ii •� I�„„, i -rte c_..._ _ u .. 1 15/16"DIA /m'_IF---I III- — [49.2mm] , "°; i I lit- 2 27/32"DIA. i I L_n�u` i_i..,� [72.2mm] 1 ;-- Horizontal Sidewall i1 TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER `\`. WRENCH BOSS. Li • -H 1 ADJUSTMENT 013FG03A (1) REFER TO ESCUTCHEON DATA TABLE FOR APPROVALS AND DIMENSIONS. (2) FM APPROVED FOR 4" - 6"[101.6MM - 152.4MM] CEILING TO DEFLECTOR. Note: For Recessed HSW Sprinklers use installation wrench GFR2. 3. Model Fl FR56 Quick Response Concealed Pendent Sprinklers Installation Wrench: Model RC1 Sprinkler Wrench Technical Data: "K"Factor Temp.Rating Max. Bulb Sprinkler Nominal Thread Model Ambient Approvals Identification Orifice US Metric Size Sprinkler Cover Temp Color pp Number(SIN) 1/2"(15mm) 5.6 80 1/2" NPT F1FR 135°F/57°C 135°F/57°C 100°F/38°C Orange 1,2 RA1414 1/2"(15mm) 5.6 80 1/2"NPT F1FR 155°F/68°C 135°F/57°C 100°F/38°C Red 1, 2,411> RA1414 1/2"(15mm) 5.6 80 1/2" NPT F1FR 175°F/79°C 165°F/74°C 100°F/38°C Yellow 1,2 RA1414 1/2"(15mm) 5.6 80 1/2" NPT F1FR 200°F/93°C 165°F/74°C 100°F/38°C Green 1,2 RA1414 (1)For VdS'only= 155°F/68°C Norbulb and 1/2"[12,7mm]adjustment. /-x 1/2"REDUCING TEE OR ELBOW --r ________ 1"x 1/2"REDUCING Tr TEE OR ELBOW E Iii. + ,-Ff 11- 11 E ilrif -, l r-� 2 5/8"D/A. a i 2 5/16" DIA — '1 HOLE IN CEILING --r—) 1 r- 2 5/8"D/A. CUP L�m� ,>• 4 2 5/16"0/A — - HOLE IN CEILING .:� 'II�� Iii 1 1/2"MAX. CUP .� "I FACE OF FITTING fi[ it'1,L� 1 1/2"MAX. TO FACE OF CEILING FACE OF FITTING iii. ii __ "� �: _ T; .-:7 DIMENSION I TOOF ♦ I :� ,1��11FACE CEILING CEILING .111111 - / -&T /_ 1 q jT:::''/: After installation, inspect all sprinklers to ensure that Sprinkler Types there is a gap between the cover plate and ceiling and Standard Upright that the four cup slots are open and free from any air flow Standard Pendent impediment to the space above. Conventional Concealed cover plate/cup assemblies are listed only Recessed Pendent for use with specific sprinklers. The use of any other con- Vertical Sidewall cealed cover plate/cup assembly with the Model F1FR56 Horizontal Sidewall Pendent Sprinkler or the use of the Model CCP Concealed Recessed Horizontal sidewall cover plate assembly on any sprinkler with which it is not Concealed pendent specifically listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. Maximum Working Pressure Glass bulb sprinklers have orange bulb protectors to 175 psi (12 bar) minimize bulb damage during shipping, handling and 100% Factory tested hydrostatically to 500 psi (34.5 bar) installation. REMOVE THIS PROTECTION AT THE TIME Finishes (1) THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Removal of the protectors before this Standard Finishes time may leave the bulb vulnerable to damage. RASCO Sprinkler Escutcheon Cover plate Bronze Brass wrenches are designed to install sprinklers when covers Chrome Plated Chrome Chrome are in place. REMOVE PROTECTORS BY UNDOING THE White Polyester Plated White CLASP BY HAND. DO NOT USE TOOLS TO REMOVE Coated(4X5) White Painted THE PROTECTORS. Special Application Finishes Sprinkler Escutcheon Cover plate Temperature Ratings Bright Brass(3) Bright Brass Bright Brass Sprinkler Black Plated Black Plated Satin Max. Ambient Black Paint(2) Black Paint Off White Classification Temperature Bulb Color °C °F Temp. Off White(2) Off White Black Paint Satin Chrome Satin Chrome Black Plated Ordinary 57 135 100°F(38°C) Orange (1) Other finishes and colors are available on special order. Ordinary 68 155 100°F(38°C) Red Consult the factory for details. Intermediate 79 175 150°F(66°C) Yellow (2) cULus Listed only. Intermediate 93 200 150°F(66°C) Green (3) 200°F(93°C)maximum. High(1) 141 286 225°F(107°C) Blue (4) cULus listed"corrosion resistance"applies to SIN Numbers (1)Not available for recessed sprinklers. RA1425(Upright)and RA1414(Pendent)in standard black or white. (5) FM Approvals finish as"Polyester coated"applies to SIN Number Escutcheon Data (1) RA1414(Pendent)in standard black or white. Face of Fitting to Escutcheon Approvals Adjustment `A' Ceiling or Wap Ordering Information Model Dknension Dimension Specify: F1 1,3,4 Max Recess 11/2"(38.1mm) ahs"-15/16" 1. Sprinkler Model Min Recess 3/4"(19.1mm) (5mm-24m) 2. Sprinkler Type Max F2 1,2,3,4 Recess 11/2 (38.1mm) 3/18'-11/16" 3. Orifice Size Min Recess 1"(25nm) (5mm-17mm) FPPush-cni Max Recessed 7/16"(11mm) 11/2"(38.1mm) 4. Deflector Type Thread-off 1,4 Min Recessed 15/16(24m) 1"(25.4mm) 5. Temperature Rating (1)SIN:RA1435-cULus and FM permits use with Fl or F2 escutcheons for light 6. Sprinkler Finish hazard only. 7. Escutcheon Type 8. Escutcheon Finish (where applicable) Maintenance 9. Cover plate Model The Models F1FR56 and F1FR56 Recessed Sprinklers 10. Cover plate Thread size should be inspected quarterly and the sprinkler system 11. Cover plate Temperature maintained in accordance with NFPA 25. Do not clean 12. Cover plate Adjustment sprinklers with soap and water, ammonia or any other 13. Cover plate Finish cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has Note:When Model F1FR56 Recessed sprinklers are ordered,the sprin- been painted (other than factory applied) or damaged klers and escutcheons are packaged separately. in any way. A stock of spare sprinklers should be main- tained to allow quick replacement of damaged or oper- ated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging to mini- mize the potential for damage to sprinklers that would cause improper operation or non-operation. 5. Bulletin 176 Rev. C E Ns ® Model F1 Re I lalb le Residential Sprinklers for Design Density of .10 gpm/ft2 0 Model Fl Res Sprinklers Listed to meet the minimum design density as required by UL1626. Types: - , 1 . F1 Res 30 Pendent ,' ; • Application Model Fl Res Sprinklers are used for Residential Fire Pro- K=7.6)that will provide lower pressure demands for tection according to UL 1626 Standard. Be sure that orifice 0.1 gpm/ft2 densities in NFPA 13 residential applica- size, temperature rating, deflector style and sprinkler type tions. are in accordance with the latest published standards of Example No. 1 The National Fire Protection Association or the approving Room Size= 12 ft x 20 ft(3.6 m x 6.1 m) authority having jurisdiction. Coverage Area= 12 x 20 = 240 ft2 (22.3 m2) When usingFl Residential Sprinklers for p systems designed Flow @ 0.10 gpm/ft2density= 240 x 0.10 = 24 gpm to NFPA 13D or NFPA 13R, use listed area of coverage and Using an Fl Res 49 Pendent Sprinkler, K=4.9 minimum flow and pressure requirements shown in Bulletin Pressure= (24/4.9)2 = 24 psi (1.65 bar) 135. The baseline flow for a 20 ft x 20 ft(6.1 m x 6.1 m) cover- For systems designed to NFPA 13, use information in this age area using the baseline density of 0.05 gpm/ft2 will bulletin. The number of design sprinklers shall be the most be 20 gpm @ 16.7 psi (75.7 L/min @ 1.14 bar). There- hydraulically demanding sprinklers as required by NFPA fore, the minimum flow required is 24 gpm @ 24 psi (90.8 13. Flows and pressures can not be below the baseline L/min @ 1.65 bar). flows and pressures. NFPA 13 Example No. 2 For residential sprinkler systems designed to NFPA 13, a Room Size= 8 ft x 20 ft(2.4 m x 6.1 m) minimum density of 0.1 gpm/ft2 must be provided over the Coverage Area= 8 x 20 = 160 ft2(14.9 m2) "design area" that includes the four (4) hydraulically most Flow @ 0.10 gpm/ft2 density= 160 x 0.10 = 16 gpm demanding sprinklers for the actual coverage areas being Using an Fl Res 49 Pendent Sprinkler, K=4.9 protected by the 4 sprinklers. The minimum required dis Pressure= (16/4.9)2 = 10.7 psi (0.74 bar) charge from each of the four most hydraulically demanding The baseline flow for a 20 ft x 20 ft(6.1 m x 6.1 m) cover sprinklers shall be the greater of the following: age area using the baseline density of 0.05 gpm/ft2 will 1. The flow rates given in the Reliable Residential be 20 gpm ® 16.7 psi(75.7 L/min @ 1.14 bar). Therefore, Sprinkler Technical Bulletins referenced in Table A the minimum flow required is 20 gpm @ 16.7 psi (75.7 for NFPA 13D and 13R as a function of temperature L/min @ 1.14 bar). rating and maximum allowable coverage area (for actual coverage areas less than or between those Example No. 3 indicated in the respective technical bulletin, it is re-, Room Size= 10 ft x 16 ft(3.0 m x 4.91 m) quired to use the minimum required flow for the next Coverage Area= 10 x 16 = 160 ft2 (14.9 m2) largest coverage area); or Flow @ 0.10 gpm/ft2 density= 160 x 0.10 = 16 gpm 2. A minimum discharge density of 0.1 gpm/ft2 applied Using an Fl Res 76 Pendent Sprinkler, K=7.6 over the"design area"consisting of the four most by The baseline flow for a 16 ft x 16 ft coverage area is 21 draulically demanding sprinklers for the actual coy gpm @ 7.6 psi (79.5 L/min @ 0.52 bar). Therefore, the erage areas being protected by the four sprinklers, minimum flow and pressure is 21 gpm @ 7.6 psi (79.5 The maximum dimension of the actual coverage area L/min @ 0.52 bar). cannot be any greater than the maximum coverage Example No. 4 area indicated in the technical bulletins referenced Room Size= 14 ft x 18 ft(4.3 m x 5.5 m) in Table A. Coverage Area= 14 x 18 = 252 ft2(23.6 m2) Design Note: Using the As = S x L method to de Flow @ 0.10 gpm/ft2 density= 252 x 0.10 - 25.2 gpm termine the sprinkler protection area of coverage in (94.6 L/min) accordance with NFPA 13,apply the 0.1 gpm/ft2den Using an Fl Res 76 Pendent Sprinkler, K=7.6 city to this area to determine the minimum required Pressure= (252/7.6)2 = 11 psi (0.76 bar) flow. Compare this flow to the minimum 0.05 gpm/ft2 The baseline flow and pressure of an 18 ft x 18 ft cover- cULus Listed flow for the appropriate coverage area age area is 21 gpm @ 7.6 psi (79.5 L/min @ 0.52 bar). in the technical bulletin for the specific residential Therefore, the minimum flow and pressure is 25.2 gpm @ sprinkler. If the flow stated in the technical bulletin 11 psi (94.6 L/min @ 0.76 bar). is less than the calculated 0.1 gpm/ft2 density flow required,the .1 density flow must then be used in the In general residential sprinklers require flows and equation Q=KVI5, solving for P, to establish the mini pressures as listed for 0.05 densities to achieve the mum required pressure using the sprinkler K-factor. Note: In many cases the listed flow of individual resi proper spray pattern so the flows and pressures at dential sprinklers may exceed the required minimum 0.05 density are the baseline flows and pressures. 0.05 gpm/ft2 density. Reliable has available resi Flows and pressures below the listed 0.05 density dential sprinklers with larger K-factors (K=5.8 and shall not be used. 2 Installation Models F1 Res sprinklers are to be installed as shown. Use of wrenches other than those specified may dam- Model Fl, F2 and FP Escutcheons, illustrated herewith, age these sprinklers. are the only recessed escutcheons to be used with Mod- Note: A 'leak tight" sprinkler joint can be obtained with el Fl Res sprinklers. Use of any other recessed escutch- the following torque: eon will void all approvals and warranties. For installing • 3/4" NPT (R3/4)— 14-20 ft-lbs (19 - 27.1 N-m) Model Fl Res Pendent sprinklers use only the Model D • 1/2" NPT(R72)—8-18 ft-lbs (10.8—24.4 N-m) sprinkler Wrench; for installing Models Fl Res Recessed Do not tighten sprinklers over maximum recom- Pendent, CCP sprinklers use only the Model GFR2 sprin- mended torque. It may cause leakage or impairment kler wrench; for installing Model F1 Res recessed HSW of the sprinklers. sprinklers use only the Model GFR2 Sprinkler wrench. • Model Fl Res 30, 49, 58 & • Model Fl Res 30, 49, 58 & 76 76 Pendent Recessed Pendent / Fl/F2 X ,. \\.107 ,,x,' . i'' 1 F1 escutcheon, 3/4" (19mm) adjustment Note: See escutcheon table for dimensions. L.__2 1/4"HOLE DIA_J -----.\,------ [522mm] � 1 15/16'DN. __I (492mm] 1 1 - 1:==-7ff._______ - X 1/2'REDUCER TURN COLLAR UNTIL I LIGHT AGLNST SPRINKLER WRENCH BOSS. i 1 --_ ` FACE OF TITLING TO [ - EILMO OIYENSION: i_ 7i_ 7 ` f - C- J/16-IS/16(FL ESCUTCHEON) v _ I 3/I6-11/16(F2 ESCUTCHEON) 'II 411illitJT[Jfi l_0 OS l . ADJ}EM �I 035V1 III I///���/ W. \le ....�.�.�. .�.... 135FGO2A . 2 27/J2'DB. [72.2mm] 135FG03 Fig. 1 Fig. 2 3. Technical Data: F1Res 30 Pendent and Recessed Pendent(SIN R3511) Thread Nominal Orifice Max. Sprinkler Max. Actual Sprinkler Size Inch(mm) Pressure Temp. Rating Ambient Temp. K Length psi(bar) °F °C °F °C Factor Inch(mm) 1/2"NPT 155 (R1/2) 8 21/64"(8.2) 175(12) 175 7g 100 38 3.0 2.25(57) **Baseline flows and pressures for 0.05 density Max. Coverage area Max. Ordinary Temp. Bating Intermediate Temp. Rating Top of Deflector Minimum g Spacing (155 F/68 C) (175 F/79 C) to Ceiling Spacing Ft x Ft(m x m) Flow Pressure Flow Pressure Ft(m) GPM(L/min) PSI(bar) GPM(1../min) PSI(bar) Inch(mm) Ft(m) 12 x 12(3,6 x 3,6) 12(3,6) 8(30,3) 7.0(0,48) 8(30,3) 7.0(0,48) 1 to 4(25 to 100); 1/2 recessed using 8(2,4) 14 x 14(4,3 x 4,3) 14(4,3) 10(37,8) 11 (0,76) 10(37,8) 11 (0,76) F2 escutcheon For Ceiling types refer to NFPA 13, 13R or 13D **Calculate for a .10 density but in no case go below the baseline flows & pressures Technical Data: Fl Res 49 Pendent and Recessed Pendent Nominal Sprinkler Max. Max. Sprinkler Escutcheon*, Fl or F2, Data: Actual Thread Orifice Temp. Pressure Ambient Length Face of fitting to Size Inch Rating psi Temp. K InchAdjustment "A" Factor Type ceiling (mm) °F °C (bar) °F °C (mm) Inch(mm) Inch(mm) Inch(mm) 1/2"NPT7/x,(11) 155 68 175(12) 100 38 4.9 2.25(57) Min.=3/4(19.1) 3/16-15/16 (R1/2) 175 79 150 66 F1 3/4"(19.0) Max.=1'/2(38.1) (4.7 24.0) **Baseline flows and pressures for 0.05 density F2 1/2"(127) Min.=15/,6(23.8) 3/,6-"/,6 Max.=11/2(38.1) (4.7-17.4) Deflector-to-ceiling *Note:Escutcheons F1 or F2 may be used with Model F1 Res 49&58 Recessed Pendent Sprinkler Maximum 1" (25mm)to 4" (100mm) *Deflector-to-ceiling Max Sprinkler Flow Pressure Sprinkler Maximum 4"(100mm)to 8" (203mm) Spacing Identification Max Sprinkler ft (m) gpm(Lpm) psi(bar) Number(SIN) Flow Pressure Sprinkler Spacing)g gpm(Lpm)psi(bar) Identification 12 x 12(3.6x3.6) 13(49) 7.0(0.48) ft m Number(SIN) 14 x 14(4.3x4.3) 13(49) 7.0(0.48) 12 x 12(3.6x3.6) 15(57) 9.4 (0.65) 16 x 16(4.9x4.9) 13(49) 7.0(0.48) R3516 14 x 14(4.3x4.3) 16(60.5) 10.6(0.73) 18 x 18(5.5x5.5) 17(64.3) 12.0(0.83) 16 x 16(4.9x4.9) 17(64.3) 12.0(0.83) R3516 20x20(6.1x6.1) 20(75.7) 16.7(1.14) 18 x 18(5.5x5.5) 19(72) 15.0(1.0) 20x20(6.1x6.1) 22(83.2) 20.2(1.4) *Note: The F1 Res 49 pendent and recessed pendent residential sprinklers can be installed per NFPA 13 in beamed ceilings meeting the following criteria: 1. Maximum beam depth=7"(178mm) 2. Beam spacing at or greater than 7.5 ft.(2.3m)on center. Technical Data: Fl Res 58 Pendent and Recessed Pendent Sprinkler Temp. Max. Thread Size Nominal Orifice Rating Max. Pressure Ambient Temp. K Sprinkler Length Inch (mm) °F °C psi (bar) °F °C Factor Inch (mm) 1/2"NPT(R1/2) 1/2 (13) 155 68 175(12) 100 ' 38 5.8 2.25(57) 175 79 150 66 **Baseline flows and pressures for 0.05 density Max. Sprinkler Spacing Flow Pressure Ceiling-to-Deflector Sprinkler Identification ft(m) gpm(Lpm) psi(bar) Inch (mm) Number(SIN) 12 x 12(3.6x3.6) 16(61) 7.6(0.53) 14 x 14(4.3x4.3) 16(61) 7.6(0.53) 1-4 16 x 16(4.9x4.9) 16(61) 7.6(0.53) (25-100) R3513 18 x 18(5.5x5.5) 19(72) 10.8(0.75) 20 x 20(6.1x6.1) 22(83.3) 14.4(1.0) **Calculate for a .10 density but in no case go below the baseline flows & pressures 4. Technical Data: Fl Res 76 Pendent and Recessed Pendent • SprinklerMax. Escutcheon*, Fl or F2, Data: Nominal Max Sprinkler Thread Temp. Ambient K Face of fitting Orifice Pressure Length Adjustment "A" SizegInch(mm) .F Rating aC psi(bar) °F0 Factor Inch(mm) Type to ceiling Inch(mm) Inch(mm) Inch(mm) 3/4"NPT /32(13.5) 155 68 175(12) 100 7.6 2.25(57) F1 3/4(19.0) Min.=3/4(19.1) 3/16-15/16(4.7 24.0) (R3/4) 175 79 150 66 Max.=11/2(38.1) * F2 /2(12.7) Min.=15/16(23.8) 3/t6.11/s(4.7-17.4) Baseline flows and pressures for 0.05 density Max.=11/2(38.1) Max.Sprinkler Flow pressure Sprinkler Spacing gpm(Lpm) psi(bar) Identification *Calculate for a .10 density but in no case go ft(m) Number(SIN) below the baseline flows & pressures 12x 12(3.6x3.6) 21 7.6(0.53) 14 x 14(4.3x4.3) 21 7.6(0.53) 16 x 16(4.9x4.9) 21 7.6(0.53) R7618 18 x 18(5.5x5.5) 21 7.6(0.53) 20x 20(6.1x6.1) 23 9.2(0.63) • Model Fl Res 30, 49, 58 & • Model Fl Res 30, 49, 58 & 76 CCP Pendent* 76 Recessed Pendent / FP ft, ',.. ' „.. 001 ‘, FP push-on/thread-off *Not listed for corrosion resistance. escutcheon . 8"[66.7mm] D/A. 2 5/8.DIA[66.Jmm] 2 5/8" HOLE IN CEILING 2 5/16"D/A. HOLE IN CEILING [58.7mm] 2 5/16"DIA mj CUP LS----- L--==_ '_= 1 1"x1/2"REDUCER � H-77-==---.-7---- ---_=7-E=i I 1"X 1/2'REDUCER CUP I Jrr�/ CEILING =_� 1 j �II[•_7L_I�� 1 1/4"[31.5mm] \ 1 / T",1 Iat‘ `ro' MAX FACE OF FITTING - 1 '` TO FACE OF CEILING ♦ r I A 41 T�n DIMENSION CEILING L J � � ,,,. � ice, -- — T - -•-•• '8" i. FACE OF FITTING COVER ADJUSTMENT (TQC\ III jillVIlli TO FACE OF CEILING HEIGHT 1\\ .\ - IIIc II ,iI �" DIMENSION C 3 5/16"DIA. I 1/2•Cdord,,wx\. .-......,i, •'1 " ji 17 A I ,l } 135FG04D [84.1mm] FP AUUS MEN �41„��� i Fl RES 30, 49, 58 & 76 CCP PEND. 135FGOtA Fig. 3 Fig. 4 NOTE: The Fl Res 76 will use a 1" x 34" reducer. 5. Technical Data: F1Res 30 CCP Pendent and Recessed Pendent/FP (SIN R3511) CCP Assembly Max. Thread Nominal Orifice Max. Pressure K Sprinkler Length Temp. Rating Ambient Temp. Size Inch (mm) psi (bar) °F °C °F °C Factor Inch (mm) i ''/z"NPT(R1/2) 21/64"(8.2) 175(12) 135 57 100 38 3.0 2.25(57) *Baseline flows and pressures for 0.05 density Ordinary Temp. Rating Max. Coverage area Max.Spacing (155°F/68°C) Top of Deflector Minimum m x m Ft m to Ceiling Spacing Ft x Ft ( ) ( ) Flow Pressure Inch (mm) Ft(m) GPM(Umin) PSI(bar) 12 x 12(3,6 x 3,6) 12(3,6) 8(30,3) 7.0(0,48) 1 to 4(25 to 100); 1/2(13mm)recessed 8(2,4) 14 x 14(4,3 x 4,3) 14(4,3) 11 (37,8) 13.4(0,92) using FP escutcheon For Ceiling types refer to NFPA 13, 13R or 13D *Calculate for a .10 density but in no case go below the baseline flows & pressures Technical Data: Fl Res 49 CCP Pendent and Recessed Pendent/FP CCP Options Data: Nominal CCP Max. Sprinkler "A" Sprinkler Max. Thread Orifice Assembly Ambient K Length Cover Temp. Rating Pressure CCP Height Size Inch Temp. Rating Temp. Factor Inch Adjustment (mm) °F °C °F °C psi(bar) °F °C (mm) Inch (mm) Inch (mm) 1/2"NPT7/16"(11) 155 68 135 57 175(12) 100 38 4.9 2.25(57) 1/2(12.7) 15/16(24) (R1/2) 3/16(4.7) 3/4 (19) *Baseline flows and pressures for 0.05 density FP Data "A": Max. Sprinkler Sprinkler "A" Spacing Flow Pressure Identification FP Position Inchmm ft(m) gpm(Lpm) psi(bar) Number(SIN) Inch ( ) Max.Recessed 7/16(ii) 12 x 12(3.6x3.6) 13(49) 7.0(0.48) 14 x 14(4.3x4.3) 13(49) 7.0(0.48) Min. Recessed 5/16(24) 16 x 16(4.9x4.9) 14(53) 8.2(0.56) R3516 Note:Sprinklers shown in Fig.3 and Fig. 4 are not suitable for in- 18 x 18(5.5x5.5) 18(68.1) 13.5(0.93) stallation in ceilings which 20 x 20(6.1x6.1) 20(75.7) 16.7(1.14) have positive pressure in the space above. Technical Data: Fl Res 58 CCP Pendent and Recessed Pendent/FP Sprinkler CCP Assembly Max.Ambient Sprinkler Nominal Orifice Max. Pressure K Thread Size Temp. Rating Temp. Rating Temp. Length Inch Inch (mm) °F °C °F °C psi (bar) °F °C Factor (mm) '/z"NPT(R1/2) Y (13) 155 68 135 57 175(12) 100 38 5.8 2.25(57) *Baseline flows and pressures for 0.05 density Max. Sprinkler Spacing Flow Pressure Sprinkler Identification ft(m) gpm(Lpm) psi(bar) Number(SIN) 12 x 12(3.6x3.6) 16(61) 7.6(0.53) 14 x 14(4.3x4.3) 16(61) . 7.6(0.53) 16 x 16(4.9x4.9) 16(61) 7.6(0.53) R3513 18 x 18(5.5x5.5) 19(72) 10.8(0.75) 20 x 20(6.1x6,1) 22(83.3) 14.4(1.0) *Calculate for a .10 density but in no case go below the baseline flows & pressures 6. Technical Data: Fl Res 76 CCP Pendent and Recessed Pendent/FP Nominal Orifice Sprinkler Temp. CCP Assembly Max.Ambient Sprinkler Thread Size Rating Temp. Rating Max. Pressure Temp. K Length Inch (mm) psi (bar) Factor `F °C °F °C °F °C Inch (mm) 3/4"NPT(R3/4) 17/32"(13.5) 155 68 135 57 175(12) 100 38 7.6 2.25(57) 175 79 150 66 *Baseline flows and pressures for 0.05 density Max. Sprinkler Spacing Flow Pressure Sprinkler Identification ft(m) gpm(Lpm) psi (bar) Number(SIN) 12 x 12(3.6x3.6) 21 7.6(0.53) 14 x 14(4.3x4.3) 21 7.6(0.53) *Calculate for a .10 density but in 16 x 16(4.9x4.9) 21 7.6(0.53) R7618 no case go below the baseline flows 18 x 18(5.5x5.5) 22 8.4(0.58) & pressures 20 x 20(6.1x6.1) 25 10.8(0.74) • Model Fl Res 44 & 58 HSW • Model Fl Res 44 & 58 Recessed HSW/F2 t . *,.....-[,i,-*-0.,-, _,. ., • t x l r i } --\'' \ i I 1 Fl Res 44 & 58 Recessed HSW/F2 Technical Data: Fl Res 44 HSW& HSW/F2 Escutcheon, F2, Data: Sprinkler Max. Face of Fitting to Thread Nominal Temp. Max. Ambient K Sprinkler Type Adjustment wall Size Orifice Rating Pressure Temp. Factor Length Inch (mm) Inch (mm) Inch (mm) psi (bar) o o Inch (mm) °F °C F �. F2 1/2(13) 3/16-"/.5(4.7- 17.4) /z"NPT 3/8(10) 155 68 175(12) 100 38 4.4 2.45(62) (R1) 175 , 79 150 66 *Baseline flows and pressures for 0.05 density «A„ Max. Sprinkler Sprinkler Sprinkler Ceiling-to- Flow Pressure Spacing Temp. Rating Identification Deflector gpm(Lpm) psi (bar) ft(m) Inch (mm) °F(°C) Number(SIN) 12 x 12(3.6x3.6) 155(68) 175(79) 12(45.4) 7.5(0.52) 14 x 14(4.3x4.3) 155(68) 175(79) 14(53.0) 10.2(0.71) 16 x 16(4.9x4.9) 4-6 155(68) 175(79) 16(60.6) 13.3(0.92) 16 x 18(4.9x5.5) (101-152) 155(68) 175(79) 18(68.1) 16.8(1.16) 18 x 18(5.5x5.5) 155(68) 175(79) 19(72.0) 18.7(1.29) 16 x 20(4.9x6.1) 155(68) 175(79) 23(87.1) 27.4(1.89) R3531 12 x 12(3.6x3.6) 155(68) 175(79) 14(53.0) 10.2(0.71) 14 x 14(4.3x4.3) 155(68) 175(79) 16(60.6) 13.3(0.92) 16 x 16(4.9x4.9) 6 12 155(68) 175(79) 17(64.4) 15.0(1.04) (152-305) 16 x 18(4.9x5.5) 155(68) 175(79) 20(75.7) 20.7(1.43) 16 x 20(4.9x6.1) 155(68) 175(79) 23(87.1) 27.4(1.89) *Calculate for a .10 density but in no case go below the baseline flows & pressures 7. • Model Fl Res 44 SWC* f (101.60mm To 1 ) st 1 1/4'[31.75mm]Maximum 304.80mm ""• Face Of Fitting PUSH ON COVER, THEN ''''''''"'".....Z � .., To Wolf Dimension TURN TO ADJUST UNTIL . ,.,_ - '3 X77 TIGHT AGAINST WALL. ,434,,e..' "- t l"X 1/2"Reducer d%% } f r 1 -, ---= Recommended �'�u Wall Hole 2 5/16" n moi//iii 2 5/8" [58.74mmJ.)J_5—f — �_ - - - - _ [66.68mm) Dia. i O/6;0%% (84.14m1 . m I Die. , �1 .• 1 TURN COLLAR UNTIL ..i TIGHT AGAINST SPRINKLER �'� 12/ 32" -�._- WRENCH BOSS. "' / [42.07mm) 135FG07 --.1 f 1/2"[12.70mm] Not listed for corrosion resistance. Adjustment F1 RES 44 SWC Fig. 5 Technical Data: Fl Res 44 SWC Sprinkler Cover Max. Thread Nominal Temp. Temp. Max. Ambient K Sprinkler Size Orifice Rating Rating Pressure Temp. Factor Length Inch (mm) °F °C °F aC psi (bar) °F °C Inch (mm) '/2"NPT 3/8(10) 155 68 135 57 175(12) 100 38 4.4 2.45(62) (R/z) *Baseline flows and pressures for 0.05 density Max. "A" Ceiling -to- Flow Pressure Sprinkler Sprinkler Spacing Deflector Identification ft(m) Inch (mm) gpm(Lpm) psi(bar) Number(SIN) 12 x 12(3.6x3.6) 13(49.2) 8.7(0.60) 14 x 14(4.3x4.3) 14(53.0) 10.2(0.71) 16x16(4.9x4.9) (101-152) 17(64.3) 15.0(1.1) 16 x 18(4.9x5.5) 19(71.8) 18.7(1.13) 16 x 20(4.9x6.1) 23(87 1) 27.4(1.89) R3531 12 x 12(3.6x3.6) 14(52.9) 10.2(0.71) 14 x 14(4,3x4.3) 6.12 15(56.7) 11.7(0.81) 16 x 16(4.9x4.9) (152-305) 18(68.1) 16.8(1.16) 16 x 18(4.9x5.5) 20(75.6) 20.7(1.43) *Calculate for a .10 density but in no case go below the baseline flows & pressures 8. Technical Data: Fl Res 58 HSW & HSW/F2 Sprinkler Max. Escutcheon, F2, Data: Thread Nominal Temp. Max. Ambient K Sprinkler Orifice Pressure Length Face of Fitting to Size Rating Temp. Factor g Adjustment Type wall Inch (mm) °F °C psi (bar) °F oC Inch (mm) Inch(mm) Inch (mm) 1/"NPT 1/2(13) 155 68 175(12) 100 38 5.8 2.45(62) F2 1/2(13) 3/16-11/16(4.7- 17.4) (R1/2) 175 79 150 66 *Baseline flows and pressures for 0.05 density Max. A Sprinkler Sprinkler Ceiling-to- Flow Pressure Sprinkler Spacing Temp. Rating Identification Deflector ft(m) Inch (mm) °F(°C) gpm(Lpm) psi(bar) Number(SIN) 12 x 12(3.6x3.6) 155(68) 175(79) 16(60.6) 7.6(0.53) 14 x 14(4.3x4.3) 155(68) 175(79) 18(68.2) 9.7(0.67) 16 x 16(4.9x4.9) (101-152) 155(68) 175(79) 21 (79.5) 13.2(0.91) 16 x 18(4.9x5.5) 155(68) 175(79) 25(94.7) 18.6(1.28) 16 x 20(4.9x6.1) 155(68) 175(79) 29(109.8) 25(1.73) R3533 12 x 12(3.6x3.6) 155(68) 175(79) 22(83.3) 14.4(1.0) 14 x 14(4.3x4.3) 6-12 155(68) 175(79) 22(83.3) 14.4(1.0) 16 x 16(4.9x4.9) (152-305) 155(68) 175(79) 26(98.4) 20.1 (1.39) 16 x 18(4.9x5.5) 155(68) 175(79) 31 (117.4) 28.6(1.97) *Calculate for a .10 density but in no case go below the baseline flows & pressure 9. Technical Data: F1 Res 58 HSWX(SIN RA3533) Nominal Max. Sprinkler Max. Sprinkler Sprinkler Thread Orifice Pressure Temp. Rating Ambient K Length Identification Size Inch (mm) psi(bar) ° Temp. Factor Inch Number(SIN) F °C °F C (mm) Bulb 1/z"NPT 1/2"(13) 175(12) 155 68 100 38 5.8 2.45(62) RA3533 (Rh) 175 79 150 66 *Baseline flows and pressures for 0.05 density f- Ordinary Temp. Rating Intermediate Temp. Max. Max. Spacing (1550F/68°C) Rating Top of Deflector , Minimum Coverage area 1 Ft(m) (175°F/79°C) to Ceiling Spacing Ft x Ft(m x m) Flow Pressure Flow Pressure Inch (mm) Ft(m) GPM(L/min) PSI(bar) GPM(L/min) PSI(bar) 18 x 20(5,5 x 6,1) 18(5,5) 30(114) 26.8(1,85) 30(114) 26.8(1,85) 20 x 20(6,1 x 6,1) 20(6,1) 30(114) 26.8(1,85) 30(114) 26.8(1,85) 4 to 6(100 to 152); 16 x 22(4,9 x 7,3) 16(4,9) 33(125) 32.4(2,23) 33(125) 32.4(2,23) 1/2(13)recessed using F2 escutcheon 16 x 24(4,9 x 7,3) 16(4,9) 38(144) 42.9(2,96) 38(144) 42.9(2,96) 14 x 26(4,3 x 7,9) 14(4,3) 42(160) 52.4(3,75) 42(160) 52.4(3,75) 8(2,4) 18 x 20(5,5 x 6,1) 18(5,5) 35(133) 36.4(2,5) 35(133) 36.4(2,5) 16 x 22(4,9 x 6,7) 16(4,9) 38(144) 42.9(2,9$) 38(144) 42.9(2,96) 6 to 12(152 to 305); 1(13)recessed 16 x 24(4,9 x-7,3) 16(4,9) 42(160) 52.4(3,6) 42(160) 52.4(3,6) using F2 escutcheon 14 x 26(4,3 x 7,9) 14(4,3) 46(174) 62.9(4,34) 46(174) 62.9(4,34) For Ceiling types refer to NFPA 13, 13R or 13D *Calculate for a 0.10 density but in no case go below the baseline floor and pressures. • Model Fl Res 58 HSWX(Bulb) FACE OF FITTING TO - " +'' F WALL DIMENSION - s, 1 11/16"MIN. -2 1/4"HOLE DIA. X1/8 [31.8mm] A, *�.< ., s, [572mm] CEILING TO "' .1 [3.2mm] DEFLECTOR 1"X 1/2"REDUCER DIMENSION / ill OA -�}rC= 4 i ,,c �iI%//mo- ,.�.e_mm___..- 1 15/16 DIA. /v�_ - 111' '` [49.2mm] ' iim I�Zfi ;': ""-'mac 22732"DIA. I r ������._ / `_"u y,� [72.2mm] • Model KRes58 HSWX (Link) TURN COLLAR UNTIL 41 i TIGHT AGAINST SPRINKLER WRENCH BOSS. --H -.- 1/2"[13mm] 135FG08 ADJUSTMENT F1 RES 58 HSWX t ' ir t s Fig. 6 - X I . ,. Ai& - h 10. Technical Data: KRes58 HSWX (RA3593) Max. Sprinkler Nominal Max. Sprinkler Thread Orifice Pressure Ambient K Length Identification Size Inch (mm) psi (bar) Temp. Factor Inch Number(SIN) °F °C (mm) Link '/2"NPT 1/2„(13) 175(12) 100 38 5.8 2.45(62) RA3593 (R'/2) *Baseline flows and pressures for 0.05 density Ordinary Temp. Rating Top of Deflector Minimum Max.Coverage area Max. Spacing . (165°F/74°C) to Ceiling Spacing Ft x Ft(m x m) Ft(m) Flow Pressure Inch (mm) Ft(m) GPM(L/min) PSI(bar) 18 x 20(5,5 x 6,1) 18(5,5) 29(109) 25(1,72) 20 x 20(6,1 x 6,1) 20(6,1) 30(114) 26.8(1,85) 4 to 6(100 to 152); 16 x 22(4,9 x 7,3) 16(4,9) 33(125) 32.4(2,23) Y (13)recessed using F2 escutcheon 16 x 24(4,9 x 7,3) 16(4,9) 38(144) 42.9(2,96) 14 x 26(4,3 x 7,9) 14(4,3) 42(160) 52.4(3,75) 8(2,4) 18 x 20(5,5 x 6,1) 18(5,5) 35(133) 36.4(2,5) 16 x 22(4,9 x 6,7) 16(4,9) 38(144) 42.9(2,96) 6 to 12(152 to 305); 1(13)Recessed 16 x 24(4,9 x 7,3) 16(4,9) 42(160) 52.4(3,6) using F2 escutcheon 14 x 26(4,3 x 7,9) 14(4,3) 46(174) 62.9(4,34) For Ceiling types refer to NFPA 13, 13R or 13D *Calculate for a 0.10 density but in no case go below the baseline floor and pressures. Maintenance Model Fl Res 30, 49, Fl Res 58 & Fl Res 76 Sprin- manufacturer's installation guidelines and the appli- klers should be inspected and the sprinkler system cable installation standard. Where pendent residential maintained in accordance with NFPA 25, 13, 13D, and sprinklers are installed under sloped ceilings having 13R. Do not clean sprinkler with soap and water, Am- a pitch from [4/12] to [8/12], the sprinklers shall be monia or any other cleaning fluids. Remove dust by listed for such use. Deflector-to-ceiling distance list- using a soft brush or gentle vacuuming. Remove any ing shall be 1" to 8" maximum. Sprinkler frame and de- sprinkler which has been painted (other than factory flector shall be of bronze frame construction having a applied)or damaged in any way.A stock of spare sprin- 1" NPT thread. Water seal assembly shall consist of a klers should be maintained to allow quick replacement Teflon* coated Belleville spring washer with top-loaded I of damaged or operated sprinklers. Prior to installation, extruded or cold head cup with 3 mm glass bulb con- sprinklers should remain in the original cartons and taining no plastic parts, and having a temperature rat- packaging until used. This will minimize the potential ing of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall for damage to sprinklers that could cause improper op- have a nominal K-factor of 4.9 & 5.8. Standard finish: eration or non-operation. [Bronze] [Chrome-plated] [White Polyester] [Special Model F1 Res 30, 49 & 58 Pendent Sprinkler finish-specify]. Residential pendent sprinklers shall be Reliable Model F1 Res 49 & 58, SIN R3516 & R3513 Specifications (Bulletin 135). Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential pen- dent sprinklers engineered to provide a minimum de- sign density of 0.10 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential • sprinklers shall be installed in conformance with the I "DuPont Registered Trademark 11. Model F1 Res 30,49&58 Recessed Pendent/F1, Model F1 Res 30,49& 58 Recessed Pendent/F2, plate adjustment. Cover plate temperature rating shall be Model F1 Res 30,4.9&58 Recessed Pendent/FP 135°F(57°C). A plastic protective cap shall be provided Sprinklers shall be [cULus Listed] [New York City MEA and factory installed inside the sprinkler cup to protect Approved (258-93-E)] low flow residential recessed pen- the sprinkler from damage, which could occur during dent sprinklers engineered to provide a minimum design construction before the cover plate is installed. Standard density of 0.10 gpm/ft2 over the listed coverage area. cover plate finish: [White] [Custom Color-specify].].Con- Listed flows as specified by the manufacturer's technical cealed pendent sprinklers shall be Reliable Model Fl Res data sheets are to be used. Residential sprinklers shall 49&58 CCP, SIN R3516&R3513(Bulletin 135). be installed in conformance with the manufacturer's instal- Model Fl Res 44, Fl Res 58 Horizontal lation guidelines and the applicable installation standard. Sidewall, Fl Res 58 HSWX & KRes58 HSWX Where pendent residential sprinklers are installed under sloped ceilings having a pitch from [4/12] to [8/12], the Residential Sprinkler Specifications sprinklers shall be listed for such use. Deflector-to-ceiling Sprinklers shall be [cULus Listed] low flow residen distance listing shall be 1"to 8"maximum.Sprinkler frame tial horizontal sidewall sprinklers engineered to pro and deflector shall be of bronze frame construction hav vide a minimum design density of 0.10 gpm/ft2 over ing a'/2"NPT thread. Water seal assembly shall consist of the listed coverage area. Listed flows as specified a Teflon* coated.Belleville spring washer with top-loaded by the manufacturer's technical data sheets are to be I extruded or cold head cup with 3 mm glass bulb contain- used. Residential sprinklers shall be installed in con- ing no plastic parts, and having a temperature rating of formance with the manufacturer's installation guide [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a lines and the applicable installation standard. Where nominal K-factor of 4.9 (70). Standard finish: [Bronze] horizontal sidewall residential sprinklers are installed [Chrome-plated] [White Polyester] [Special finish- spec- under sloped ceilings having a pitch from [4/12] to ify]. Recessed escutcheon assembly shall be a steel, [8/12],the sprinklers shall be listed for such use. Sprin two-piece escutcheon [with '/2" adjustment (Model F2)] kler frame and deflector shall be of bronze frame con [with 3/4" adjustment (Model F1)] [of push on and thread struction having a 1" NPT thread. Water seal assem- { off design with 1"adjustment(Model FP)].Standard finish bly shall consist of a Teflon coated Belleville spring shall be [brass][bright chrome] [white painted]. Residen- washer with top-loaded extruded or cold head cup tial recessed pendent sprinklers shall be Reliable [Model with 3 mm glass bulb containing no plastic parts, and Fl Res 49 & 58 Recessed Pendent/F1] [Model Fl Res having a temperature rating of [155°F (68°C)] [175°F 49 & 58 Recessed Pendent/F2] [Model Fl Res 49 & 58 (79°C)]. The solder element (Link) version, the water Recessed Pendent/FP]SIN R3516&R3513(Bulletin 135). seal consist of a cap with a bellville spring washer and a temperature rating of 165°F (74°C). The recessed Model Fl Res 30, 49 & 58 CCP Pendent assembly forthe HSWX(Bulb& Link) should be a steel (Concealed) two pieces escutcheon with 1/2" adjustment (Model Sprinklers shall be [cULus Listed] [New York City MEA F2) standard finish should be Bright Chrome and white Approved (258-93-E)] low flow residential concealed painted. The Fl Res 58 HSW is also available with low sprinklers engineered to provide a minimum design den- lead frame. Fl Res 58 HSW and HSWX sprinklers shall sity of 0.10 gpm/ft2 over the listed coverage area. Listed have a nominal K Factor of 5.8 and Fl Res 44 a nomi- flows as specified by the manufacturer's technical data nal K factor of 4.4. Standard finish: [Bronze] [Chrome- sheets are to be used. Residential sprinklers shall be in- plated] [White Polyester] [Special finish- specify]. stalled in conformance with the manufacturer's installa- Residential horizontal sidewall sprinklers shall be Reli- tion guidelines and the applicable installation standard. able Model Fl Res 44, Fl Res 58, Fl Res 58 HSWX & Where pendent residential sprinklers are installed under Model KRes58 HSWX, SIN R3531, RA3533 & RA3593 sloped ceilings having a pitch from [4/12] to [8/12], the (Bulletin 135). sprinklers shall be listed for such use. Sprinkler frame and deflector shall be of bronze frame construction having a 1/2" NPT thread. Water seal assembly shall consist of a I Teflon* coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb contain- ing no plastic parts, and having a temperature rating of 155°F (68°C). Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange. Meth- od of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a 1/2" cover I "DuPont Registered Trademark 12. Model Fl Res 44 & 58 Recessed Horizontal Sidewall Sprinkler Residential recessed pendent sprinklers shall be Reliable Use description for the Model Fl Res 58 horizontal [Model F1 Res 76 Recessed Pendent/F1] [Model Fl Res sidewall sprinkler with the following modifications: Re- 76 Recessed Pendent/F2] [Model Fl Res 76 Recessed place "horizontal sidewall sprinkler" with "recessed hori- Pendent/FP]SIN R7618(Bulletin 135). zontal sprinkler." Add: Recessed escutcheon assembly Model Fl Res 76 CCP Pendent (Concealed) shall be a steel, two-piece escutcheon with 1/2" adjust Sprinklers shall be [cULus Listed] low flow residential ment (Model F2). Standard finish shall be [brass][bright concealed sprinklers engineered to provide a minimum chrome] [white painted] [Special finish— specify]. Resi design density of 0.10 gpm/ft2 over the listed coverage dentia) recessed horizontal sidewall sprinklers shall be area. Listed flows as specified by the manufacturer's Reliable Model F1 Res 58/F2, SIN R3513(Bulletin 135). technical data sheets are to be used. Residential sprin- Model Fl Res 76 Pendent klers shall be installed in conformance with the manufac- Sprinklers shall be [cULus Listed] low flow resi- turer's installation guidelines and the applicable installa- dential pendent sprinklers engineered to provide a tion standard. Sprinkler frame and deflector shall be of minimum design density of 0.10 gpm/ft2 over the list- bronze frame construction having a 3/4"NPT thread. Water ed coverage area. Listed flows as specified by the seal assembly shall consist of a Teflon-coated Belleville manufacturer's technical data sheets are to be used. spring washer with machined or cold head cup with 3 Residential sprinklers shall be installed in conformance mm glass bulb containing no plastic parts, and having a with the manufacturer's installation guidelines and the temperature rating of 155°F (68°C). Cover plate assem- applicable installation standard. Sprinkler frame and bly shall consist of a brass cover plate and copper alloy deflector shall be of bronze frame construction having retainer flange. Method of attaching the cover plate to the a 3/4" NPT thread. Water seal assembly shall consist of sprinkler cup shall be a push-on and thread-off design a Teflon-coated Belleville spring washer with machined allowing a '/2" cover plate adjustment. Cover plate tern- or cold head cup with 3 mm glass bulb containing no perature rating shall be 135°F (57°C). A plastic protec- plastic parts, and having a temperature rating of[155°F tive cap shall be provided and factory installed inside the (68°C)] [175°F(79°C)]. Sprinklers shall have a nominal sprinkler cup to protect the sprinkler from damage, which K-factor of 7.6. Standard finish: [Bronze] [Chrome-plat- could occur during construction before the cover plate ed] [White Polyester] [Special finish—specify]. Residen- is installed. Standard cover plate finish: [White] [Custom tial pendent sprinklers shall be Reliable Model Fl Res Color—specify]. ]. Concealed pendent sprinklers shall be 76, SIN R7618 (Bulletin 135). Reliable Model F1 Res 76 CCP, SIN R7618(Bulletin 135). Model Fl Res 76 Recessed Pendent/F1, Finishes(') Model Fl Res 76 Recessed Pendent/F2, Standard Finishes Model Fl Res 76 Recessed Pendent/FP Sprinkler Fl, F2, FP Escutcheons Sprinklers shall be [cULus Listed] low flow residen Bronze Brass tial recessed pendent sprinklers engineered to provide Chrome Plated Bright Chrome Plated a minimum design density of 0.10 gpm/ft2 over the listed White Polyester Coated(2) White Painted coverage area. Listed flows as specified by the manu Special Application Finishes facturer's technical data sheets are to be used. Residen- tial sprinklers shall be installed in conformance with the Sprinkler Fl,F2,FP Escutcheons manufacturer's installation guidelines and the applicable Electroless Nickel Electroless Nickel installation standard. Sprinkler frame and deflector shall PTFE(Teflon®)")2) PTFE(Teflon®)* Bright Brass Bright Brass be of bronze frame construction having a 3/4" NPT thread. Black Plated Black Plated Water seal assembly shall consist of a Teflon-coated Bel- Black Paint Black Paint leville spring washer with machined or cold head cup with Off White Off White 3 mm glass bulb containing no plastic parts, and having Chrome Dull Chrome Dull a temperature rating of [155°F (68°C)] [175°F (79°C)]. (1)Other finishes and colors are available on special order. Consult factory for details. Sprinklers shall have a nominal K-factor of 7.6. Standard (2)cULus listed Corrosion Resistant. finish:[Bronze][Chrome-plated][White Polyester][Special finish—specify]. Recessed escutcheon assembly shall be Ordering Information a steel, two-piece escutcheon [with 1/2" adjustment(Mod- Specify: el F2)] [with 3/4" adjustment (Model F1)] [of push-on and 1. Sprinkler Model thread off design with '/2" adjustment (Model FP)]. Stan 2. Sprinkler Type dard finish shall be[brass][bright chrome][white painted]. 3. Temperature Rating 4. Sprinkler Finish I *DuPont Registered Trademark 5. Escutcheon Finish 13. Bulletin 157 Rev. K NM ® Model F3QR co 5. ReliableQuick Response cri Cary Sprinklers C Features ,t 1. The Model F3QR sprinkler utilizes Belleville Spring - , Closure Technology. Reliable is the first in the industry to produce a Quick Response Dry Concealed sprin- kler utilizing this technology. 2. Styles available 4 ` • Pendent • Recessed FP Pendent • Recessed Fl Pendent ' • Concealed • Horizontal Sidewall Pendent Pendent/HB • Recessed FP Horizontal Sidewall (See Fig. 1) (See Fig. 2) • Recessed Fl Horizontal Sidewall 3. 11/2"(38mm)escutcheon adjustment on pendent sprinkler. 4. 1/2" (13mm) escutcheon adjustment on recessed sprin- kler with push-on/thread-off FP Model Escutcheon ring. 5. 3/8" (9.5mm) cover plate adjustment on concealed sprinkler with push-on/thread-off CCP Cover Plate. 6. 3/4" (19mm) escutcheon adjustment on recessed '$, sprinkler with Fl Escutcheon. 7. Attractive appearance. Employs 3mm frangible glass 4. 0 bulb and galvanized nipple. Recessed FP Pendent Concealed 8. Lengths available to accommodate installation di- . (See mensions from 2" - to - 48" (51mm - to - 1219mm), in Fig. 3) (See Fig. 4) 1/4" (6mm) increments. See specific styles for correct "A" dimension range. 9. Available in a variety of plated and painted finishes. 10.Polyester Coated or Electroless Nickel PTFE (Teflon®)* Plated Corrosion Resistant Sprinklers. .~ *Concealed Sprinkler is not corrosion resistance. US Patent Numbers 5,775,431 and 5,967,240. ,._...: ` Other US Patents pending. Approvals Recessed Fl Pendent Horizontal Sidewall 1. Listed by Underwriters Laboratories Inc. and UL (See Fig. 5) (See Fig. 6) Certified for Canada (cULus) Style Response Sprinkler Hazard System Type 4.- Pendent 1 Recessed FP Pendent Wet Pipe Light Recessed Fl Pendent Quick Dry Pipe Ordinary r ,._ ,, °- CCP Concealed All Preaction (R5714) Horizontal Sidewall Wet Pipe Recessed Horizontal Sidewall Quick Dry Pipe Light Horizontal Sidewall/HB F1 &FP(R5734) All Preaction (See Fig. 7) 2. Certified by FM Approvals Style Response Sprinkler Hazard System Type Pendent Wet Pipe Light � , Ordinary, f Recessed El Pendent Quick Dry Pipe f (R5714) All Preaction Groups . ' ; 'l+ Horizontal Sidewall Wet Pipe Recessed Fl Horizontal Sidewall Quick Dry Pipe Light (R5734) All Preaction Recessed FP Recessed Fl 3. NYC MEA 258-93-E Horizontal Sidewall Horizontal Sidewall (See Fig. 8) (See Fig. 9) "DuPont Registered Trademark Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model F3QR Dry Pendent Sprinkler "A"Dim. 2"to 48"(51mm to 1219mm)in'/a"(6mm)increments Finishes Sprinkler Escutcheon Electroless Nickel PTFE(Teflon®)*(4) Electroless Nickel PTFE(Teflon®)* Bronze Brass(3) Chrome Chrome White Polyester(2( White (1)Other finishes and colors are available on special order.Consult factory for details. (2)cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. (3)Not available for HB escutcheons. (4)cULus listed Corrosion Resistant rz s(21 i f -j - - - 1- r -' ' J 1_s—� r zJ I, \ I System Tee N 1" NPT 2 1/8" Dia. [54.0mm] "A" Dimension Hole in Ceiling ' Adjustment Range —1/4" [-6.4mm] 1 43/64" Die. +1 1/4" [+31.8mm] [42.5mm] 1 1/2" [38.1mm] Total Adjustment Sprinkler Can 1 Ceiling ( 1/4" [31.8mm] / 1/4" [6.4mm] Escutcheon Esutchen Ceiling Ceiling Adjcustment o • +....H `� Nominal Position 1 5/8"[41.3mm] of Escutcheon 1/4" [6.4mm] Protrusion 3" Dia. _ _ [76.2mm] 1570001 Fig. 1 Note: The sprinkler can protrudes 1/4"when escutcheon is in nominal position. Escutcheon adjustment provides-1/4" (-6mm)to +11/4" (+32mm) "A"dimension adjustment range. Sprinkler Guard: Model C-2 Sprinkler Installation Wrench: Model F3 Sprinkler Wrench Sprinkler Identification Number(SIN): R5714 *DuPont Registered Trademark 2. Model F3QR Dry Pendent w/HB Escutcheon "A"Dim. 31"to 48"(89mm to 1219mm)in 1/4"(6mm)increments Standard Temperature Ratings Classification Sprinkler Temperature Max. , Bulb Color Rating Ambient Temp. Ordinary 135°F (57°C) 100°F (38°C) Orange Ordinary 155°F (68°C) 100°F (38°C) Red Intermediate(1) 175°F (79°C) 150°F (66°C) Yellow Intermediate 200°F (93°C) 150°F (66°C) Green High 286°F(141°C) 225°F(107°C) Blue (1)Listed and Certified only by cULus. Electroless Nickel PTFE(Teflon®)°Plated sprinklers,escutcheons and cups are recommended for exterior applications. ,!dH 11 11 4 - 4111 ,__, -..='_. 1 __HAH_LIE ___,, 1 .-=J System Tee ! NPT 2 1/2" [63.5mm] i "A" Dimension Dia. Hole in Ceiling Adjustment Range –1/2" [-12.7mm] - I 3 1/2" [88.9mm] +1/2" [+12.7mm] Escutheon Dia. 1/2" [12.7mm-I Escuthecn Adj. Cei!ir,g 1 ! f 1' [25.4] Escutcheon ME —1\ Total Adj. 1/2" [12.7mm] ! Escutheon Adj. [ Nominal Position Sprinkler Can_ I of Escutcheon 1 1-1/4" [31.75mm] 1 5/8" Nominal Protrusion lip [41.3mm] i 1 157FG02 2 13/64" [55.88mm] _ Dia. Fig. 2 Note: The sprinkler can protrudes 11/4"when escutcheon is in nominal position. Escutcheon adjustment provides-1/2"(-12.7mm)to+1/2"(+12.7mm) "A"dimension adjustment range. Sprinkler Guard: Model C-2 Sprinkler Installation Wrench: Model F3 Sprinkler Wrench Sprinkler Identification Number(SIN): R5714 `DuPont Registered Trademark 3. Model F3QR Dry Recessed FP Pendent Sprinkler "A"Dim. 31/2"to 48"(89mm to 1219mm)in 1/4"(6mm)increments Finishes"' Standard Temperature Ratings Sprinkler Escutcheon Sprinkler Max. Electroless Nickel PTFE(Teflon9"(3( Electroless Nickel PTFE (Teflon®)*)O) Classification Temperature Ambient Bulb Color Bronze Brass Rating Temp. Chrome Chrome Ordinary 135°F (57°C) 100°F (38°C) Orange White Polyester(2) White Ordinary 155°F (68°C) 100°F (38°C) Red (1)Other finishes and colors are available on special order. Intermediate(1) 175°F (79°C) 150°F (66°C) Yellow Consult factory for details.Cup remainds unfinished, Intermediate 200°F (93°C) 150°F (66°C) Green Only the escutcheon will contain desired finish. High(1) 286°F(141°C) 225°F(107°C) Blue (2)cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. (3)cULus Listed Corrosion Resistant Sprinkler. Sprinkler cup and FP Escutcheon fabricated of steel and recommended (4)Cup and Escutcheon Electroless Nickel PTFE(Teflon°)"Plated. for interior applications. of Listed and Certified only by cULus. 7 z s 7 __7 E--+AFI — , i 0 iii, \_-2----4 -_____[� " ,-- J H i System Tee ■ 1 ' NPT 2 1/2" Dia. - _� [63.50mm Hole in Ceiling "A" Dimension Adjustment Range ±1/4" 2 19/64" Dia. [±6.35mm] [58.34mm Nominal Position Sprinkler of Escutcheon Cup Assembly Escutcheon Ceiling ,We • ' i1IIj Ceilig 1/4" [6.35mm] i T I Escutcheon Adjustment 1/4" [6.35mm _1 1, 3 7/32" Dia. —0.-- Escutcheon Adjustment _81 .76mm] 1/2" [12.7mm] Total Adjustment 157FG03 Fig. 3 Note: Do not install the Model F3QR Dry Recessed FP Pendent Sprinkler in ceilings which have positive pressure in space above. Sprinkler Installation Wrench: Model XLO2 Sprinkler Wrench Sprinkler Identification Number(SIN): R5714 "DuPont Registered Trademark 4. Model F3QR Dry Pendent Concealed Sprinkler "A"Dim. 31/2"to 48"(89mm to 1219mm)in 1/4"(6mm)increments CCP Cover Plate"' Finishes (2) Standard Temperature Ratings Standard Finishes Special Application Finishes Sprinkler Max. Chrome Plated Bright Brass Plated Classification Temperature Cover Plate Ambient White Black Plated Rating Temp.Rating Temp. Black Paint Ordinary 135°F (57°C) 135°F (57°C) 100°F (38°C) Off White Ordinary 155°F (68°C) 135°F (57°C) 100°F (38°C) Satin Chrome Intermediate(1 175°F (79°C) 165°F (74°C) 150°F (66°C) (1)Utilizes the 1/2"cover plate with 3/8"total adjustment. Intermediate 200°F (93°C) 165°F (74°C) 150°F (66°C) (2)Other finishes and colors are available on-special order. High(1) 286°F(141°C) 165°F (74°C) 150°F (66°C) Consult factory for details. Sprinkler cup fabricated of steel and CCP Cover Plate fabricated of brass and recommended for interior applications. (1)Listed and Certified only by cULus. 2 11 1---- 1 T---{FF---illi b � � I` - j11111 rIilili 1 1 :=.---...==.- 1 \ -� �� System Tee 111 1" NPT 2 1/2" Dia. N_ [6.35mm] "A" Dimension Hole in Ceiling Adjustment Range ± 3/16" 2 19/64" Dia. [±4.76mm] [58.34mm] I Nominal Position of Coverplate Sprinkler 1 Cup Assembly ,...111 Coverplate I ' Ceiling (f�- Assembly y • -.,,' I I. 1� Ceiling 3/16" [4.76mm] Coverplate Adjustment 3/16" [4.76mm] — / Coverplate Adjustment f 3 5 16" Dia. [84.13mmj 3/8" [9.53mm] — Total Adjustment 757F004 Fig. 4 Note: Do not install the Model F3QR Dry Concealed Pendent Sprinkler in ceilings which have positive pressure in the space above. Sprinkler Installation Wrench: Model XLO2 Sprinkler Wrench Sprinkler Identification Number(SIN): R5714 `DuPont Registered Trademark 5. Model F3QR Dry Recessed Fl Pendent Sprinkler "A"Dim. 31/2"to 48"(89mm to 1219mm)in 1/4"(6mm)increments Finishes (1) Sprinkler Escutcheon Collar Electroless Nickel PTFE(Teflon®)"(3) Electroless Nickel PTFE(Teflon®)* Electroless Nickel PTFE(Teflon®)* Chrome Chrome Chrome White Polyester(2) White White (1)Other finishes and colors are available on special order. Consult factory for details. (2)cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. (3)cULus Listed Corrosion Resistant Sprinkler. Standard Temperature Ratings Sprinkler Max. Classification Temperature Ambient Bulb Color Rating Temp. Ordinary 135°F (57°C) 100°F (38°C) Orange Ordinary 155°F (68°C) 100°F (38°C) Red Intermediate(1) 175°F (79°C) 150°F (66°C) Yellow Intermediate 200°F (93°C) 150°F (66°C) Green High(1) 286°F(141°C) 225°F(107°C) Blue (1)Listed and Certified only by cULus. �s >(_z LSystem Tee Kt\ 1" NPT 2 1/2" Dia. [63.50mm] Hole in Ceiling 1 15/16" "A" Dimension [49.2mm] Adjustment Range • ± 1/4" [±6.35mm] 15/16"5/16" Nominal Position i [23.8mm] of Escutcheon Sprinkler �� Cup Assembly Ceiling 1/8"�; ' Ceiling [[3.2mm] 1/4" [6.35] ip Escutcheon Adjustment 1/4,, [6.35] ---'— Escutcheon Adjustment Escutcheon 1/2" [12.7mm] — Adjustment 2 27/32" [72.2mm] 1570005 Fig. 5 Sprinkler Installation Wrench: Model XLO2 Sprinkler Wrench Sprinkler Identification Number(SIN): R5714 "DuPont Registered Trademark 6. Model F3QR Dry Horizontal Sidewall Sprinkler "A"Dim. 2"to 48"(51mm to 1219mm)in 1/4"(6mm)increments Finishes"' Sprinkler Escutcheon Electroless Nickel PTFE(Teflon°))4) Electroless Nickel PTFE(Teflon°) Bronze Brass(3) Chrome Chrome White Polyester(2) White (1)Other finishes and colors are available on special order. Consult factory for details. (2)cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. (3)Not available for HB escutcheons. (4)cULus listed Corrosion Resistant 1 1/2" [38.10mm] —. ► Total Adjustment Ceiling a 4" [101 .60mm] Mln. N_ 12" [304.80mm] Max. 1 1/4" [31 .75mm] Escutcheon Adjustment 1/4" [6.35mm] System Tee Escutcheon Adjustment 1 " NPT pi 2 3/32" A [5 3.1 8mm] -- T 40 , ri _______ ' zr I [76.20mm] 1I T; 2 1/8" Dia. o [53.98mm Hole in Wall 0.- -.II1/4" [6.35mm] Sprinkler Can • Protrusion "A" Dimension Adjustment Nominal Position Range — 1/4" [-6.35mm] of Escutcheon 757Fc06 + 1 1/4 [+31 .7 5M11-11 Fig. 6 Note: The sprinkler can protrudes'/"when escutcheon is in nominal position. Escutcheon adjustment provides-1/4"(-6mm)to +11/4" (+32mm) "A" dimension adjustment range. Sprinkler Installation Wrench: Model F3 Sprinkler Wrench Sprinkler Identification Number(SIN): R5734 "DuPont Registered Trademark 7. Model F3QR Dry HSW w/HB Escutcheon "A"Dim. 31/2"to 48"(89mm to 1219mm)in 1/4"(6mm)increments Standard Temperature Ratings Sprinkler Max. Classification Temperature Ambient Bulb Color Rating Temp. Ordinary 135°F (57°C) 100°F (38°C) Orange Ordinary 155°F (68°C) 100°F (38°C) Red Intermediate"' 175°F (79°C) 150°F (66°C) Yellow Intermediate 200°F (93°C) 150°F (66°C) Green High(') 286°F(141°C) 225°F(107°C) Blue (1)Listed and Certified only by cULus. 1 " [25.4mm] ► Total Adjustment Ceiling J 1/2" [12.7mm] Escutcheon Adjustment 4" [101.60mm] Min. /2" [12.7mm] — ^^� 12" [304.80mm] Max. Escutcheon Adjustment 2 3/32" System Tee ! [53. 8mm] /� SPT ' — � 1 1 �I► I..II rjk r-- 2-13/64" i I F ll, I ISI, i I ; i �" Dia. L88.9mm, -�Ap-....:.1 „i I �T'�- Escutcheon Dio. 1 2 1/2" Dia. '� I [63.5mm i Hole in WallI.- l _ --11/4" [31.75mm] Nominal r Protrusion t Sprinkler Can "A" Dimension — Escutcheon Adjustment Nominal Position ?57FC07 Range + 1/2" [+1 2.7mm] of Escutcheon - 1/2" [-12.7mm] Fig. 7 Note: The sprinkler can protrudes 11/4"when escutcheon is in nominal position. Escutcheon adjustment provides-1/2"(-12.7mm)to+1/2"(+12.7mm) "A"dimension adjustment range. Sprinkler Installation Wrench: Model F3 Sprinkler Wrench Sprinkler Identification Number(SIN): R5734 "DuPont Registered Trademark 8. Model F3QR Dry Recessed FP Horizontal Sidewall Sprinkler "A"Dim. 31/2"to 48"(89mm to 1219mm)in'/4"(6mm)increments Finishes 11) Standard Temperature Ratings Sprinkler Escutcheon Sprinkler Max. Electroless Nickel PTFE(Teflon(2)*(3) Electroless Nickel PTFE (Teflon®)*(4( Classification Temperature Ambient Bulb Color Bronze Brass Rating Temp. Chrome Chrome Ordinary 135°F (57°C) 100°F (38°C) Orange White Polyester White Ordinary 155°F (68°C) 100°F (38°C) Red (1)Other finishes and colors are available on special order. Intermediates) 175°F (79°C) 150°F (66°C) Yellow Consult factory for details.Cup remainds unfinished."See page 2" Intermediate 200°F (93°C) 150°F (66°C) Green (2)cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. High Cl) 286°F(141°C) 225°F(107°C) Blue (4)cULus Listed Corrosion Resistant Sprinkler. (1)Listed and Certified only by cULus. Sprinkler's can and FP Escutcheon Electroless Nickel PTFE(Teflon©) Plated recommended for exterior applications. 4 Ceiling 1 13/32" Escutcheon [35.7mm] 4" [101 .6mm]Min. System Tee Cup 0 12" [304.8mm_Max.* \, J / 1" NET �, i //:;" / ,\ (I. H, ii I3 7/32" Dia. \\/_ice )6114 1 [81 .8mm] ��� - // 1 i ) 1_ 2 1/2" Dia. [63.5mm] Hole in WallNominal Position of Escutcheon 2 19/64" Dia. _ [58.3mm] �• 1/4" [6.35] Escutcheon Adjustment "A" Dimension --.4 Adjustment Range — 1-....-- 1/2" [12.7mm] , 157FG08 ±1/4" Escutcheon Adjustment [±6.35mm] —�1 1/4" [6.35] Escutcheon Adjustment * • FOR FACTORY MUTUAL (FM) • 4" — 6" FOR UNDERWRITERS LABORATORIES (UL) Fig. 8 . Notes: Do not install the Model F3QR Dry Recessed FP Horizontal Sidewall Sprinkler in walls which have positive pressure in their side space. • Listed by cULus for Quick Response.Approved by FM for Standard Response. • Recessed Horizontal sidewall sprinklers are listed with cULus for installation of min.4"(100mm)-to-max.6"(150mm)below ceiling and ap- proved by FM for installation of min.4"(100mm)-to-max. 12"(300mm)below ceiling. Sprinkler Installation Wrench: Model XLO2 Sprinkler Wrench Sprinkler Identification Number(SIN): R5734 *DuPont Registered Trademark 9. Model F3QR Dry Recessed Fl Horizontal Sidewall Sprinkler "A"Dim. 31/2"to 48"(89mm to 1219mm)in 1/4"(6mm)increments Finishes (1) Standard Temperature Ratings Sprinkler Escutcheon Collar Sprinkler Max. Classification Temperature Ambient Bulb Color Electroless Nickel Electroless Nickel Electroless Nickel Rating Temp. PTFE(Teflon®)*(3' PTFE(Teflon®)" PTFE(Teflon)" Ordinary 135°F (57°C) 100°F (38°C) Orange Chrome Chrome Chrome Ordinary 155°F (68°C) 100°F (38°C) Red White Polyester(/) White White Intermediate(1) 175°F (79°C) 150°F (66°C) Yellow Intermediate 200°F (93°C) 150°F (66°C) Green "'Other finishes and colors are available on special order. High(1) 286°F(141°C) 225°F(107°C) Blue Consult factory for details, (1)Listed and Certified only by cULus. (21 cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. 13)cULus Listed Corrosion Resistant Sprinkler. --—-- -- Ceiling r' t Escutcheon [i [3.2mm] F -1 4" [10) .6mm]Min. System Tee Sprinkler Cup 2 304.8mm Max. Assembly I [ ] ' NF \ "Lvv / �i „ ! 2 27/32" - — - I� I r-- h m m ii "V / ill, 111 [72.2 1_r \–_ ------Z- .+1 1 2 1/2" Dia. [63 5mml Hole in WaH I I Nominal Position 1 5/ 6" L---..- 1 of Escutcheon [49.2mm] ►• 1/4" [6.35] Escutcheon Adjustment I "A" Dimension 1/2" [1 2.7mm] 1570009 ___ Adjustment Rcnge ] Adjustment +1/4" 1 [±6.35mm] — ir-..-- 1/4" [6.35] Escutcheon Adjustment k • FOR FACTORY MUTUAL (FM) • 4" 6" FOR UNDERWRITERS LABORATORIES (UL) Fig. 9 • Listed by cULus &Approved by FM for Quick Response. • Recessed Horizontal sidewall sprinklers are listed with cULus for installation of min. 4" (100mm) - to - max. 6" (150mm) below ceiling and approved by FM for installation of min. 4" (100mm)-to-max. 12" (300mm) below ceil- ing. Sprinkler Installation Wrench: Model XLO2 Sprinkler Wrench Sprinkler Identification Number(SIN): R5734 "DuPont Registered Trademark 10. Technical Data: Note: Orifice Size: '/2" (15mm) 1. The "A" dimension is based on a nominally gauged Thread Size: 1" NPT per ANSI B2.1 pipe thread "make-up" of 0.600" (15mm) per ANSI Working Pressure: 175 psi (12 bar) B2.1 [71 threads approximately]. Nominal K Factor- US/(Metric): 5.6/(80) 2. All platings and paintings are decorative and intend- Product Description ed for interior use. Reliable Model F3QR Dry Sprinklers are quick response General Installation Instructions sprinklers utilizing a durable 3mm frangible glass bulb. This Model F3QR dry sprinklers must be installed only in stan- quick response enables these sprinklers to apply water to a dard (ANSI B 16.3 class 150 and ANSI B 16.4 class 125) fire much sooner than standard response sprinklers of the pipe tees in the horizontal position,even at branch line ends. similar temperature rating. They should not be installed into elbows or pipe couplings Model F3QR Dry Sprinklers are intended for use in dry and located on drop nipples to the sprinklers.For these and other preaction systems and in areas subjected to freezing tern- fittings including CPVC,the dry sprinkler should be installed peratures, such as freezers and unheated portions inside into a fitting to allow protrusion into the fitting in accordance and outside buildings. with the diagrams. The "A" dimension of the dry sprinkler, Environments wherein dry sprinklers are employed can which extends into the freezers or a freezing zone from wet be corrosive. For this reason, Model F3 Sprinklers have a pipe systems, should be selected to provide, as a minimum, special wax fillet placed in the gap between the cup that the specified lengths in inches shown in Fig. 10. supports the bulb and the wrenching boss.This wax will not Caution: interfere with the operation of the sprinkler, and it prevents Do not install Model F3QR Dry sprinklers into CPVC adapt- contaminents from entering the internal portion of the drop er fittings or tees that have an internal obstruction. This will nipple.The wax must not be removed. damage the sprinkler and/or the fitting. Refer to Fig. 11. Operation The glass bulb consists of an accurately controlled amount During installation, the following steps must be followed: of special fluid hermetically sealed inside a precisely manu- factured glass capsule. This glass bulb is specially con- 1. Cut the specified size hole(see illustrations)for the sprin- structed to provide fast thermal response. When the tern- kler in the ceiling or wall directly in line with the tee. perature increases sufficiently, due to a fire,the bulb shatters 2. Apply pipe joint compound to the 1" (25mm) pipe allowing operating parts to clear the waterway. This enables threads and install sprinkler using the Model F3 or XLO2 the inlet seal to release air or water and subsequently,cause Sprinkler Wrench as specified', water flow over the deflector in a uniform spray pattern,con- 3. Install the Model FP push-on /thread-off escutcheon or trolling or extinguishing the fire. CCP cover plate if required. Ordering Information Note: Installation of the Model F3QR Sprinklers is not recom- Specify: mended in copper pipe systems,as this may reduce the life 1. Sprinkler Type (select one): expectancy of the sprinklers. (a) Model F3QR Dry Pendent (b) Model F3QR Dry Pendent/HB Model F3QR Concealed and Recessed In- (c) Model F3QR Dry Recessed FP Pendent stallation Instructions (d) Model F3QR Dry Recessed Fl Pendent • The Model XLO2 wrench (Fig. 12) is designed to lo- (e) Model F3QR Dry Concealed Pendent cate on the wrenching pads of the recessed sprin- (f)Model F3QR Dry Horizontal Sidewall kler while centering in the cup'. A standard 1/2" drive (g) Model F3QR Dry Horizontal Sidewall/HB ratchet may be used to drive this wrench. Fig. 13 and (h)Model F3QR Dry Recessed FP Horizontal Sidewall-UL Fig. 14 show sequentially the insertion of the wrench. (i)Model F3QR Dry Recessed Fl Horizontal Sidewall-UL First the wrench, with its jaws above the sprinkler de- &FM flector, is moved laterally until centered with the cup. 2. Sprinkler Temperature Rating. Then raise the wrench inside of the cup until its jaws 3. Sprinkler Finish. engage the sprinkler's square wrenching pads (Fig. 4. Escutcheon type (F1 or FP). 14). To remove the wrench, follow this procedure in 5. Cover Plate/Escutcheon Finish. reverse order. Care should be taken to avoid striking 6. Length: the deflector, with the wrench. "A" Dimension(face of tee to face of ceiling or wall)in 1/4" • Model F3 Wrench (Fig. 15) is used for installation of (6mm)increments. Pendent and Horizontal Sidewall sprinklers'. 7. Model F3QR Dry Pendent (a) is available without sprinkler can and escutcheon. ' Installation Wrenches: Throughout this technical bulletin,Reliable has specified specific installation wrenches for use on each version of our sprinklers.A pipe wrench may also be used to install a dry sprinkler provided that it only interfaces with the steel outer tube of the assembly(Item#8 on fig 16). Keep in mind that a pipe wrench will incorporate a large amount of torque into the final assembly.This torque will have to be matched or exceeded upon the sprinkler's removal at a later date. 11. RECOMMENDED EXPOSED MINIMUM BARREL LENGTH BASED ON AMBIENT TEMPERATURE IN THE PROTECTED AREA (STANDARD DRY PENDENT SPRINKLER SHOWN) INSTALL 1 INCH NPT THREADED END OF DRY PENDENT SPRINKLER WET PIPE INTO THE 1 INCH NAT SIDE OUTLET EXPOSED BARREL OF A MALLEABLE IRON TEE FITTING AMBIENT AMBIENT TEMPERATURE rz s PER ANSI B 16.3 (CLASS 150) TEMPERATURE ___,,,r OR CAST IRON THREADED TEE FITTING 'F/4' OF PROTECTED . 40C 50T 10'C 60'F 16'C 1:i _r d -' yl PER ANSI 16.4 (CLASS 125) ONLY. AREA* AT THE - Ilial l-�-- - -Il -'� DISCHARGE END EXPOSED MINIMUM BARREL LENGTH"* Ii i�1 OF THE SPRINKLER (FACE OF TEE TO TOP OF CEILING) i-, -14--T1 I----61____✓ IN. (MM) IN. (MM) IN. (MM) Ls-1 --,_L r l, IF HUMIDITY AND TEMPERATURE DIFFERENTIAL 40'F (4'C) 0 0 0 == CAUSES CONDENSATION ON THE EXPOSED DRY ME SPRINKLER. CONSIDER WRAPPING THE EXPOSED 30'F (-1'C) 0 0 0 BARREL WITH INSULATION, FOAM INSULATING 20'F (-7'C) 4 (101) 0 0 TAPE OR EQUIVALENT. 10'F (-12'C) 8 (203) 1 (25.1) 0 PF (-18'C) 12 (305) 3 (75) 0 MINIMUM (HEATED AREA) SEAL THE CLEARANCE SPACE -10'F EXPESED (-23'C) 14 (356) 4 (101) 1 (25.1) BARREL AROUND THE SPRINKLER TO AVOID LENGTH LEAKAGE OF AIR INTO THE PROTECTED -20'F (-29'C) 14 (356) 6 (152) 3 (75) AREA AND CONSEQUENT FORMATION OF CONDENSATE AROUND THE FRAME, WHICH I -30'F(-34'C) 16 (406) 8 (203) 4 (101) COULD INHIBIT OPERATION OR CAUSE PREMATURE OPERATION, SEE BELOW FOR -40'F (-40'C) 18 (457) 8 (203) 4 (101) RECOMMENDED METHODS L.A" CLEARANCE -50'F (-46'E) 20 (508) 10 (254) 6 (152) - DIMENSION HOLE -60'F (-51'C) 20 (508) 10 (254) 6 (152) * THE PROTECTED AREA REFERS TO THE AREA BELOW THE CEILING. THE AMBIENT TEMPERATURE IS THE TEMPERATURE AT THE DISCHARGE � END OF THE EPRINEAET. FOR PROTECTED AREA TEMPERATURES THAT OCCUR BETWEEN THE VALUES I. LISTED, USE THE NEXT COOLER TEMPERATURE. ...NW IMIN **THE MIN. REQUIRED BARREL LENGTH IS NOT THE SAME AS THE 'A' DIMENSION. ESCUTCHEON ' NOTE: EXPOSED MINIMUM BARREL LENGTHS ARE INCLUSIVE UP TO 30MPH CEILING IRO WIND VELOCITIES IN THE PROTECTED AREA. � (PROTECTED AREA) == -#---3" DIA. 1 *RECOMMENDED EXPOSED MINIMUM BARREL LENGTHS ALSO APPLY TO HORIZONTAL SIDEWALL DRY SPRINKLERS* RECOMMENDED DRY SPRINKLER SEAL ARRANGEMENTS WET PIPE (STANDARD DRY PENDENT SPRINKLER SHOWN) WET PIPE i Ft it - 1H,f' F 11TE, -Ilii I(1==== �`i i r -Hp= t,-,;, 4- II IHS- ,,_ 11 i -'� t Y• hII � �I '4- , II IIP li L„�, 1� - Dill- - l -'ti �w- YI rJ ti-fit--- w-- L--I1 MEI rL kkt=== r == S C =_ C J MIE (HEA"ED AREA) ■■ MINIMUM Ic (HEATED AREA) EXPOSED MINIMUM BARREL / EXPOSED LENGTH DECKTITE FLASHING j INSIDE FACE SEAL BARREL (SEE ABOVE) RISCO #400397; % \ \\\\ LENGTH RECOMMENDED \ (SEE ABOVE) � %////////. I/////% I %////// IIII CLEARANCE HOLE INSULATED FREEZER, OR COOLER STRUCTURE OR EXTERIOR FRAMING m lot (PROTECTED AREA) �I�'ll+ DRY COLD SPRINKLE AREAR (PROTECTED AREA) `I�� I+ DR COLD SPRINKLE AREA IN 157FG10 Fig. 10 12. *CAUTION* DO NOT INSTALL MODEL F3, MODEL F3QR OR MODEL DH56 HSW DRY SPRINKLERS INTO CPVC ADAPTER FITTINGS OR TEES THAT HAVE AN INTERNAL OBSTRUCTION. THIS WILL DAMAGE THE SPRINKLER AND/OR THE FITTING. CPVC ADAPTER FITTINGS AND TEES WITH INTERNAL OBSTRUCTIONS ARE ALSO COMMONLY FOUND DURING THE RETROFITTING PROCESS OF RELIABLE'S OLDER MODEL G3 DRY SPRINKLERS. INTERNAL NO OBSTRUCTION INTERNAL OBSTRUCTION FEMALE 4 FEMALE �! � PIPE /, ` PIPE . l 10ATHREAD THREAD INCORRECT CORRECT CPVC ADAPTER CPVC ADAPTER FITTING OR TEE FITTING OR TEE SHORTER LONGER INLET INLET MALE PIPE MALE THREAD - _ __ PIPE THREAD wm- MODEL F3-PL. MODEL F3QR-PL OR STANDARD MODEL DH56 HSW-PL MODEL F3. DRY SPRINKLER MODEL F3QR OR MODEL DH56 HSW DRY SPRINKLER BE SURE TO ORDER THE CORRECT SPRINKLERS FOR YOUR APPLICATION 016fg08A Fig. 11 13. tr. , i ' 4 Fig. 12-XLO2 Wrench Fig. 13-XLO2 Wrench Fig. 14-XLO2 Wrench r ;, A Fig. 15-F3 Wrench Maintenance • Glass bulb sprinklers have orange bulb protectors The Model F3QR Quick Response Dry Sprinklers should to minimize bulb damage during shipping, handling be inspected and the sprinkler system maintained in accor- and installation. REMOVE THIS PROTECTION AT THE dance with NFPA 25. Do not remove the factory applied TIME THE SPRINKLER SYSTEM IS PLACED IN SER- thermally sensitive wax fillet between the bulb supporting VICE FOR FIRE PROTECTION. Removal of the pro- cup and the wrenching boss. Do not replace this wax with a tectors before this time may leave the bulb vulnerable substitute substance. An Alternate substance may interfere to damage. RASCO wrenches are designed to install with proper operation of the sprinkler. Do not clean sprinklers sprinklers when covers are in place. REMOVE PRO- with soap and water, ammonia or any other cleaning fluids. TECTORS BY UNDOING THE CLASP BY HAND. DO Remove dust by using a soft brush or gently vacuuming. NOT USE TOOLS TO REMOVE THE PROTECTORS. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non- operation. 14. MATERIAL SPECIFICATIONS 14 ® ITEM# DESCRIPTION MATERIAL SPECIFICATION S. Y mu 1 FRAME BRASS PER UNS C83600 2 DEFLECTOR BRONZE PER UNS C51000 s 3 LOAD SCREW BRASS PER UNS 022000 ® 4 SEAT ADAPTOR BRASS ALLOY PER UNS C36000 II 5 BULB INSERT COPPER ALLOY PER UNS C331400 6 GLASS BULB GLASS W/GLYCERIN SOLUTION A 11 -/ 7 ORIFICE ADAPTOR BRASS ALLOY PER UNS C36000 p ' 8 OUTER TUBE GALVANIZED STEEL a 9 INNER TUBE BRASS ALLOY PER UNS C23000 , I 10 YOKE BRASS ALLOY PER UNS 038000 I / 11 INLET BRASS ALLOY PER UNS C35330 12 CAP BRASS ALLOY PER UNS C54400 ® 13 SPRING WASHER/SEAL TEFLON COATED BERYLLIUM NICKEL 14 FLIP DISK BRASS ALLOY PER UNS C54400 Z 1 \ 0 15 CAN/ESCUTCHEON PAINTED OR PLATED MILD STEEL g ,. 0 , , Fr.:111 1 0 (PIPE WRENCH MAY ONLY BE USED ON OUTER STEEL PIPE OF SPRINKLER) I . \ 11 0 ., y ®'', , ,i 1. , , I‘'.1:„„ II , 153 fg10 g© I I 757fg 16 16 O 0 c 0 APPEARANCE OF DEFLECTOR MAY VARY DEPENDING ON MODEL Fig. 16 15. Bulletin 034 Rev,A a Model G5-56 F ilebabi ® Model G5-42 Quick Response Concealed Automatic Sprinkler UL Quick Response FM Standard Response Concealed Sprinkler With a 3/4" (19mm) Adjustment .114 Features 1. Cover plate attachment (Plain or Perforated) with 3/4"(19mm)assembly adjustment. 2. Smooth aesthetic ceiling profile. 3. Factory installed protective cap. 4. Available in brass, chrome or black plated and white painted finishes. 5. Ordinary and Intermediate temperature rating. Plain Cover Plate For K2.8 &additional Sprinklers refer to Bulletin 154 for Technical Specification and Approvals Approvals & Listings 011114 1. Underwriters Laboratories Inc. and cULus- Quick Response 2. Factory Mutual Research Corp. (FM)- Standard Response (See Page 3) • Light Hazard Occupancies - _No Limitations • Ordinary Hazard Occupancies Groups 1 & 2 Wet Systems Only U.S. Patent number 6,554,077. Application Perforated Cover Plate The Reliable Model G5-56 and G5-42 are the most versatile quick response concealed sprinklers available. It provides Product Description the best form of fire protection while offering an attractive ap- The Reliable Model G5-56 and G5-42 uses a proven quick pearance and 3/4" (19mm) of cover adjustment for ease of response fusible element in a standard style sprinkler frame installation. The small diameter cover plate assembly is cos- with a drop-down deflector. This assembly is recessed into ily attached and blends into the ceiling, concealing the most the ceiling and concealed by a flat cover plate assembly. The dependable fire protection available, an automatic sprinkler threaded engagement provides 3/4" (19mm) of cover adjust- system. ment. The flat cover plate is attached to the skirt using either The Model G5-56 and G5-42 are designed for use where 135°F(57°C)or 165°F(74°C)ordinary temperature classifica- aesthetic appearance is important. Offices, hospitals, motels tion solder. and restaurants are but a few of the applications where it can When the ceiling temperature rises, the solder holding the be used. flat cover plate melts,the flat cover plate released thus expos- The Model G5-56 and G5-42 is a UL Listed Quick Response ing the sprinkler inside to the rising ambient temperature. Concealed sprinklers intended for use in accordance with The subsequent fusing of the element opens the waterway NFPA 13. FM Approves the G5-56 sprinkler as a standard re- and causes the deflector to distribute the water. Any secure sponse concealed sprinkler intended for use in accordance engagement between the cover plate and cup will assure that with FM Loss Prevention Data Sheet 2.0. the drop-down deflector is properly located below the ceiling. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Installation Ordering Information Do not install the G5-56 and G5-42 in ceilings which have 1. Sprinkler Model positive pressure in the space above. 2. Nominal Orifice • Cut a 25/"inch(67mm)diameter hole is cut in the ceiling,the 3. Flat Cover Plate sprinkler is easily installed with the Model FC Wrench. The Plain or Perforated wrench has a socket drive which is inserted into the body of 4. Flat Cover Plate Lak—d the sprinkler. When installing a sprinkler the wrench is first Assembly Finish positioned into the sprinkler/cup assembly until the wrench 5. Inlet Type socket engages the body of the sprinkler. The sprinkler is Cover Plate Finishes(1) then tightened into the pipe fitting. When inserting or remov- Standard Finishes Od ing the wrench from the sprinkler/cup assembly,care should Chrome Ow` be taken to prevent damage to the sprinkler. DO NOT White Paint WRENCH ON ANY OTHER PART OF THE SPRINKLER/ Special Application CUP ASSEMBLY. Install the cover plate by hand turning the Finishes(2) cover in the clockwise direction until it is tight against the ceil- Bright Brass Model FC Sprinkler Wrench ing. Finished Bronze UL Listing Category A protective cap is provided to protect the drop-down sprinkler Black Plating Sprinklers, Automatic and deflector from damage which could occur during construction Black Paint Open before the cover plate is installed. The cap is factory installed Off White Quick Response Sprinkler inside the sprinkler cup.Remove cap to install sprinkler,then re- Satin Chrome UL Guide Number install cap until the cover plate is installed. (1) Other finishes and colors are VN IV available on special order. Maintenance Consult factory for details. The Model G5-56 and G5-42 should be inspected quarterly Coverplate custom paint is and the sprinkler system maintained in accordance with NFPA semi-gloss, unless specified 25. Do not clean sprinklers with soap and water, ammonia or 2 otherwise. For the perforated style cover- any other cleaning fluids. Remove any sprinkler that has been plate,consult factory for avail- painted(other than factory applied) or damaged in any way. A ability on these and other cus- stock of spare sprinklers should be maintained to allow quick re- tom finishes. placement of damaged or operated sprinklers. Prior to installa- Maximum Working Pressure tion,sprinklers should be maintained in the original cartons and 175 psi (12 bar) packaging to minimize the potential for damage to sprinklers 100% Factory tested Hydrostatically to 500 psi (34.5 bar) that would cause improper operation or non-operation, Temperature Rating Classification Sprinkler Cover Max.Ambient Plate Temp. Ordinary 165°F/74°C 135°F/57°C 100°F/38°C Intermediate 212°F/100°C 165°F/74°C 150°F/66°C 2. Technical Data Sprinkler Total Nominal Nominal K Factor Thread Approvals Sprinkler Inlet Adjustment Orifice US Metric Identification (SIN) Non Adjustable 3/4"(19mm) 1/2"(15mm) 5.6 80 1/2"NPT(R1/2) 1,2 RA3415 Non Adjustable 34"(19mm) '/,,"(10mm) 4.2 60 1/2"NPT(RY) 1 RA3413 7" x 1/2" REDUCING TEE OR ELBOW H -- b - .„ J28" [66.55mm_1 2ii" [58.42mm] DIA bH �I HOLE IN CEILING L J CUP - MOW -.. MM.� I \ \�\ lit 2-1/4" OF. MAX. , NN��\ 1 FACE OF FITTING ‘N N N N‘ M TO FACE OF CEILING _ ' DIMENSION CEILING iii iiiii - 4" [19.05mm] MAX. COVER ADJUSTMENT 7'4" [4.96mm] J FLAT COVER PLATE .3i" [84.21 mm] DIA. - ASSEMBLY 16 SPRINKLER 034FGO1 COVER PLATE: 3/4- [7 9.O5mm] ADJUSTMENT Notice FOR USE AS A REPLACEMENT OF MODEL G4A SPRINKLERS 1"x 1/2'REDUCING TEE OR ELBOW 1 II 1 711 -- RELIABLE P/N 6999991900 1 3"X}'BRASS NIPPLE EXT. L J (58.42mm]DIA- %Jail HOLE IN CEILING 3-1/16"[77.72mm]MAX. CUP IFIIFACE OF FITTINGTO FACE OF CEILING DIMENSION 2-1/4'[50.8mm]MAX. `\\,,,,, FACE OF NIPPLE EXT. TO FACE OF CEILING _-. DIMENSION CEILING < iiiiiiii .•- •,, ti u....... .-. ii i"[19.05mm]MAX._ COVER ADJUSTMENT A-[4.96mm] FLAT COVER PLATE _ 31i"[84.21mm]ON. ASSEMBLY SPRINKLER • 0JFD2 COVER PLATE: 3/4" [19.05mm] ADJUSTMENT NOTE: 1. Testing has shown that use of a"nipple extension"will not affect the listing of the sprinkler. 2. For RETROFIT installations, per NFPA 13(2010)section 8.15.19.4, "which allows the use of nipples as the same pipe thread size as the existing outlet when revamping existing systems". 3. Do not exceed 8-18 ft-lbs of torque during installation. 3. Bulletin 173 Rev, B Model JL112&J112-Upright ® Extended Coverage Light Hazard ` Extended Co 0 verage Ordinary Hazard ECOH Extlended Coverage Or�diriary Hazard -Quick Response cc Model JL112 & J112 ECLH/ECOH Upright SIN RA7326 is Corrosion Resistant with White (SIN R7326 - Link and RA7326 - Bulb) Polyester Coating. • Quick Response for Light Hazard (16'x 16'(4.9m x 4.9m), 18'x 18'(5.5m x 5.5m)and - 20' x 20' (6.1m x 6.1m) spacing) • Quick Response for Ordinary Hazard (12' x 12' (3.7m x 3.7m)and 14'x 14' (4.3m x 4.3m) spacing) � A • Standard Response for Ordinary Hazard (16'x 16' (4.9m x 4.9m), 18'x 18'(5.5m x 5.5m)and 20' x 20' (6.1m x 6.1m) spacing) Features 1. Extended Coverage Ordinary Hazard and Light Hazard protection to 400 ft2(37.2 m2) per sprinkler. E 2. Nominal K = 11.2(160), Model JL112 Upright Model J112 Upright 3. Available in brass, chrome and polyester coated finishes. (R7326) - Link (RA7326) - Bulb 4. For applications as per NFPA 13. Approvals Organizations 1. Underwriters Laboratories, Inc. (UL) Design Criteria 2. Underwriters Laboratories of Canada(cULus) Reliable Model JL112 & J112 ECLH/ECOH sprinklers 3. NYC MEA 258-93-E shall only be used in systems designed and installed in UL Listing Category accordance with NFPA 13 and all other local codes and ordinances. The following design criteria also apply: Sprinklers, Automatic and Open Extended Coverage Sprinklers-Ordinary Hazard Occupancy UL Guide Num- • Minimum sprinkler spacing is 8 ft(2.44m). ber VNIV. • Sprinklers have a minimum flow requirement for each The Reliable Model JL112 and J112 sprinkler are Ex- spacing as shown in the Flow Requirements Table on tended Coverage Sprinklers for use in Ordinary Hazard the reverse side. • Sprinklers are only to be used in systems hydraulically 1 and 2 occupancies with a coverage area of up to 400 square feet(37,2m2) per sprinkler. designed per NFPA 13. For all light hazard applications it is a Quick Response • Deflector to commodity clearance shall be a minimum sprinkler. For ordinary hazard applications, it is a Standard of 18 in (457mm). Response sprinkler when the spacing is 16' x 16' (4.9m • ECOH sprinklers shall be installed in unobstructed x 4.9m) and larger. When the spacing is 12' x 12' (3.7m constructions as defined in NFPA 13. For open web x 3.7m) or 14' x 14' (4.3m x 4.3m), the sprinkler is Quick truss construction web thickness is not to exceed 1 Response for ordinary hazard applications. inch (25.4mm). The use of ECLH/ECOH sprinklers can provide lower in- • ECOH sprinklers which are installed above the bottom stallation costs by requiring fewer sprinklers, less piping of a horizontal obstruction, shall have their deflectors and reduced labor. located as shown in the Obstruction Table on page 3. ECLH/ECOH sprinklers are to be installed according to • Sprinklers can be installed under a sloping ceiling the design criteria shown in this bulletin, NFPA 13, and all not exceeding 2 inches (50.8mm) of rise in 12 inches other local codes and ordinances. Flows and pressures (305mm). as shown on pages 2 and 3 of this bulletin, must be used • Maximum working pressure is 175 psi (12.07bar) at for the appropriate spacing and for the designated hazard the sprinkler. classifications. This ECLH/ECOH sprinkler is available in various fin- ishes, which includes a white polyester corrosion resistant finish. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Sprinkler Model Specifications Temperature Max. Maximum Maximum Sprinkler Model Type Rating Ceiling Sprinkler Coverage THD Temp. Spacing Area Size Approvals °F °C °F °C ft(m) ft2(m2) JL112 ECLH/ECOH-R7326 Link/Upright 165 74 100 38 212 100 150 66 20(6.1) 400(37.2) JL112 ECLH/ECOH-R7326 Link/Upright 3/4"NPT 1,2 J112 ECLH/ECOH-RA7326 Bulb/Upright 155 68 100 38 (19mm) J112 ECLH/ECOH-RA7226 Bulb/Upright 200 93 150 66 20(6.1) 400(37.2) Flow Requirements - Light Hazard -Quick Response Spacing Coverage Area Flow Pressure "K" Factor ft(m) ft2(m2) gpm(Ipm) psi(bar) US Metric 16 x 16(4.9 x 4.9) 256(23.8) 30(113.6) 7.2(0.5) 18 x 18(5.5 x 5.5) 324(30.1) 33(124.9) 8.7(0.6) 11.2 160.0 20x20(6,1 x 6.1) 400(37.2) 40(151.4) 12.8(0.9) Flow Requirements -Ordinary Hazard -Standard Response Ordinary Hazard 1 Ordinary Hazard 2 Spacing Coverage 0.15 gpm/ft2(6.1 L/min/m2) 0.20 gpm/ft2 (8.1 L/min/m2) "K" Factor ft(m) Area Density Density ft2(m2) Flow Pressure Flow Pressure US Metric gpm(Lpm) psi(bar) gpm(Ipm) psi(bar) 16 x 16(4.9 x 4.9) 256(23.8) 39(147.6) 12.1 (0.8) 51 (193.0) 20.7(1.4) 18 x 18(5.5 x 5.5) 324(30.1) 49(185.5) 19.1 (1.3) 65(246.0) 33.7(2.3) 11.2 160.0 20 x 20(6.1 x 6.1) 400(37.2) 60(227.1) 28.7(2.0) 80(302.8) 51.0(3.5) Flow Requirements -Ordinary Hazard -Quick Response Ordinary Hazard 1 Ordinary Hazard 2 Spacing Coverage 0.15 gpm/ft2(6.1 L/min/m2) 0.20 gpm/ft2 (8.1 L/min/m2) "K" Factor ft(m) Area Density Density ft2(m2) Flow Pressure Flow Pressure gpm(Lpm) psi(bar) gpm(Lpm) psi(bar) US Metric 14 x 14(4.3x4.3) 196(18.2) 30(113.6) 7.2(0.5) 39(147.6) 12.1 (0.8) 11.2 160.0 12 x 12(3.7x3.7) 144(13.4) 2. Finishes J1 Wrench Sprinkler Finishes Sprinkler Bronze Chrome White Polyester Coated } - ..,aµ; Ordering Information 1. Sprinkler Model 2. Temperature Rating 3. Finish Corrosion Resistant Bulb Model J1 °F °C Sprinkler Wrench J112 ECLH/ECOH Use Model J1 Wrench for JL112&J112 155 68 ECLH/ECOH Upright Sprinkler Removal and 200 93 Installation Minimum Flow Requirements For Earlier Editions of NFPA 13- FOR REFERENCE ONLY NFPA13-1991 Requirements NFPA13-1989 Requirements "K"Factor Ordinary Hazard 1 Ordinary Hazard 2 Ordinary Hazard 1 Ordinary Hazard 2 Ordinary Hazard 3 0.15 gpm/ft2 0.20 gpm/ft2 0.16 gpm/ftz 0.19 gpm/ft2 0.21 gpm/ft2 Spacing Coverage (6.1 L/min/m2) (8.1 L/min/m2) (6.5 L/min/m2) (7.7 L/min/m2) (8.6 L/min/m2) ft(m) Area Density Density Density Density Density ft2(m2) US Metric Flow Pressure FloPressure Flgpmow Pressure Flow Pressure Flow Pressure m psigpmpsi gpm psi gpm 9P psi (Lpm) psi(bar) (Lpm) (bar) (bar) (Lpm) (bar) (Lpm) (bar) (Lpm) ) 14 x 14 196 30.2 7.0 39.2 11.9 31.4 7.6 37.3 10.7 41.2 13.0 (and less) (18.2) (114.3) (0.48) (148.3) (0.82) (118.8) (0.52) (141.2) (0.74) (155.9) (0.90) 16 x 16 256 38.4 11.4 51.2 20.2 41.0 12.9 48.7 18.2 53.8 22.3 (4.9 x 4.9) (23.8) (145.3) (0.79) (193.8) (1.39) (155.2) (0.89) (184.3) (1.26) (203.6) (1.54) 11.4 164.4 18 x 18 324 48.6 18.2 64.8 32.3 51.9 20.7 61.6 29.2 68.0 35.7 (5.5x5.5) (30.1) (184.0) (1.24) (258.9) (2.23) (196.4) (1.43) (233.2) (2.01) (257.4) (2.46) 20 x 20 400 60.0 27.7 80.0 49.3 64.0 31.5 76.0 44.5 84.0 54.3 (6.1 x 6.1) (37.2) (227.1) (1.91) (302.8) (3.40) (242.2) (2.17) (287.7) (3.07) (317.9) (3.75) 3. Installation Requirements for Under Concrete Tees - cULus • The stems of the concrete tee construction must be spaced at less than 7.5 feet (2.3m) on center but more than" 3 feet (0.9m) on center. The depth of the concrete tees must not exceed 30 inches (762mm). The maximum permitted concrete tee length is 32 feet (9.8m); however, where the concrete tee length exceeds 32 feet (9.8m), non-combustible baffles, equal in height to the depth of the tees, can be installed so that the longitudinal space between the tees does not exceed 32 feet (9.8m) in length. • The sprinkler deflectors are to be located in a horizontal plane at or above 1 inch (25.4mm) below the bottom of the concrete tee stems. • When the sprinkler deflectors are located higher than a horizontal plane 1 inch (25.4mm) beneath the bottom of the concrete tee stems, the obstruction to sprinkler discharge criteria requirements of NFPA13 for extended coverage upright sprinkler applies. Location of Deflector to Horizontal Obstruction Distance from Sprinkler Maximum Allowable Distance to Side of Obstruction Deflector Above Bottom of Ar,,•�,` .-�.,-,t� 4:0-4. _ 4,16 Obstruction ; ; 7 ;� WRENCH FLAT % Less than 1' (// \ 0„ j-j\ (Less than 0.305m 1'to less than 1'-6" Omm0" `� ` \ (0.305m to less than 0.305m- 152.4mm 0mm) ��r ���� \ 1'-6"to less than 2' 1" � 2-13/16 1116- 111111(0.305m- 152.4mm to less than 0.61m 25.4mm �_,,� 2'to less than 2'-6" 1" II't_. �I' I 11, (0.61m to less than 061m- 152.4mm 25.4mm) �� / 2'-6"to less than 3' 1" s a"NR, (0.61m 152.4mm to less than 0.915m 25.4mm) 3'to less than 3'-6" 3" (0.915m to less than 0.915m- 152.4mm 76.2mm) 3'-6"to less than 4' 4" LINK BULB (0.915m- 152.4mm to less than 1.22m 101.6mm) 17..01 4'to less than 4'-6" 5" (1.22m to less than 1.22m- 152.4mm 127mm) Fig. 1 4'-6"to less than 5' 7" (1.22m- 152.4mm to less than 1.525m 177.8mm) 5'to less than 5'-6" 7" (1.525m to less than 1.525m- 152.4mm 177.8mm) 5'-6"to less than 6' 7" (1.525m- 152.4mm to less than 1.83m 177.8mm) 6'to less than 6'-6" 9" (1.83m to less than 1.83m- 152.4mm 228.6mm) 6'-6"to less than 7' 11" (1.83m- 152.4mm to less than 2.135m 279.4mm) 7'and greater 14" (2.135m and greater 355.6mm) Solder Link Bulb Classification °F °C Classification °F °C Bulb Color *Ordinary 165 74 Ordinary 155 68 Red Intermediate 212 100 Intermediate 200 93 Green *Ordinary Hazard only The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Productsmanufactured and distributed by Reliable have been protecting life and property for over 90 years,and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States,Canada and foreign countries. Manufactured by mieliatild The Reliable Automatic Sprinkler Co., Inc. Recycled (800)484381:61505881 Sales Offices �� Paper (800) Sales Fax Revision lines indicate updated or new data. (914)829-2042 Corporate Offices www.reliablesprinkler.com Internet Address EG.Printed in USA 03/10 PN 9999970311 ti,sii Worldwide www.tyco-fire.com Fire Protection Contacts Products Model SW-20 and SW-24 — 11.2 K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) General rosive atmospheres.Consequently, it is recommended that the end user be Description consulted with respect to the suitability of these corrosion resistant coatings for $' , The TYCO Model SW-20 and SW-24, any given corrosive environment.The -S 11.2 K-factor, Extended Coverage Ordi- effects of ambient temperature, con- ' 4i. nary Hazard(ECOH)Horizontal Sidewall centration of chemicals,and gas/chemi- cal velocit should be considered,as a "�< Y. Sprinklers,Standard Response are dec- orative glass bulb sprinklers designed minimum, along with the corrosive na- SW-2o for use in ordinary hazard occupancies ture of the chemical to which the sprin- per NFPA 13. klers will be exposed. The SW-20 provides protection of coy- NOTICE " erage areas up to 16 ft. x 20 ft. (320 ,, ft2), whereas the SW-24 provides pro- The Model SW-20 and SW-24 Sprin- f, 40 .-� tection of coverage areas up to 16 ft.x kers described herein must be installed to ti n of co as compared to standard and maintained in compliance with this ,: * 1 document and with the applicable stan- coverage horizontal sidewall sprinklers dards of the National Fire Protection As- having a maximum coverage area of 10 sociation, in addition to the standards ft.x 10 ft. (100 ft2)for ordinary hazard of any authorities having jurisdiction. occupancies. Failure to do so may impair the perfor- SW-24 Horizontal sidewall sprinklers are de- mance of these devices. Maximum Working Pressure signed for installation along a wall or The owner is responsible for maintain- 175 psi(12,1 bar) the side of a beam and are common- ing their fire protection system and de- ly used instead of pendent or upright vices in proper operating condition. The Discharge Coefficient sprinklers due to aesthetics or building installing contractor or sprinkler manu- K. 11.2 GPM/psit/2(161,3 LPM/bar1'2) construction considerations,where pip- facturer should be contacted with any ing across the ceiling is not desirable. questions. Temperature Rating SW-20: 155°F(68°C)&200°F(93°C) Corrosion resistant coatings, where SW-24:200°F(93°C) applicable, are utilized to extend the Sp rinkler life of copper alloy sprinklers beyond Finishes that which would otherwise be ob- Identification Refer to Table B tained when exposed to corrosive at- mospheres.Although corrosion resis- Number (SIN) Physical Characteristics: tant coated sprinklers have passed the Frame Bronze standard corrosion tests of the appli- TY5332-SW-20 Button Bronze cable approval agencies,the testing is TY5337-SW-24 Sealing Assembly Beryllium not representative of all possible cor- Nickel wi TEFLON TY5332 is a re-designation for C5332 Bulb Glass TY5337 is a re-designation for C5337 Compression Screw Brass Deflector Bronze Technical Data IMPORTANT Approvals Always refer to Technical Data UL and C-UL Listed Sheet TFP700 for the "INSTALLER (Refer to the Design Criteria Section) WARNING"that provides cautions Polyester coated sprinklers are UL and with respect to handling and instal- C-UL Listed as Corrosion Resistant lation of sprinkler systems and corn- Sprinklers ponents. Improper handling and in NYC under MEA 177-03-E stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 MARCH 2014 TFP230 TFP230 Page 2 of 6 Components: 6* 5 I WRENCH 1 - Frame \ / RECESS 2 - Button ,•N'.D`�`U ° (END"B") 3 - Bulb ;1�A APPLY "i —� \ WRENCH AS 4- Compression Screw 0 II / 5- Sealing Asembly '0 %/ SHOWN 6- Deflector* `R6.AW *Temperature rating is �` indicated on Deflector. 4 3 2 1 1 " **Pipe thread connections per ISO FIGURE 3 7-1 can be provided CENTERLINE W-TYPE 3 SPRINKLER on special request. 1/2" OF SPRINKLER WRENCH WRENCH (12,7 mm) WATERWAY FLAT I3/4"** NPT = ;-)!_ / f I .. I MAXIMUM �� THROW \ 1/2" 12,7 mm 2" (50,8 mm) NOMINAL ) f \\\ MAKE-IN 6"(152,4 mm) 3/4" 2-3/8" TO 12"(304,8 mm) (19,1 mm) (60,3 mm) CEILING TO TOP 4/12 FIGURE 1 OF SPRINKLER SLOPE MODEL SW-20(TY5332) DEFLECTOR MAXIMUM EXTENDED COVERAGE ORDINARY HAZARD DISTANCE HORIZONTAL SIDEWALL SPRINKLER FIGURE 4 11.2 K-FACTOR,3/4 INCH NPT SPRINKLER PLACEMENT UNDER SLOPED CEILINGS IN Components: LOADING DOCKS 2-B Frame on �■ Operation 4- Bulb 4- Compression Screw 0 �I� g The lass bulb contains a fluid that ex- 5- Sealing Assembly pands when exposed to heat.When the 6 Deflector* \ \ rated temperature is reached, the fluid *Temperature ** expands sufficiently to shatter the glass Temperature rating is NPT bulb, allowing the sprinkler to activate indicated on Deflector. WRENCH and water to flow. FLAT **Pipe thread connections per ISO 7-1 can be provided CENTERLINE on special request. 9/16" OF SPRINKLER (14,3 mm) WATERWAY 1 5 2 ----- 6* " �11►V i—litrillniO tut• \ if ' 4 3 (���.`R►e 2.. 1/2"(12,7 mm) (50,8 mm) NOMINAL f MAKE-IN 3/4" _ 2-3/8" (19,1 mm) (60,3 mm) FIGURE 2 MODEL SW-24(TY5337) , EXTENDED COVERAGE ORDINARY HAZARD HORIZONTAL SIDEWALL SPRINKLER 11.2 K-FACTOR,3/4 INCH NPT TFP230 Page 3 of 6 MODEL SW-20 ECOH HORIZONTAL SIDEWALL SPRINKLER(TY5332) OH Group 1 (0.15 gpm/sq.-ft.) Response Coverage Minimum Minimum Deflector-To-Ceiling Sprinkler Minimum Rating Area(1), Flow(2), Pressure), Distance), Temperature Spacings4), Ft.x Ft.(m x m) GPM(LPM) PSI(BAR) In.(mm) Rating,°F Ft.(m) Standard 16 x 16(4,9 x 4,9 38(144) 11.5(0,79) 6 to 12(150 to 300) 155,200 8(2,4) Standard 16 x 18(4,9 x 5,5) 43(163) 14.7(1,01) 6 to 12(150 to 300) 155,200 8(2,4) Standard 16 x 20(4,9 x 6,1) 48(182) 18.4(1,27) 6 to 12(150 to 300) 155,200 8(2,4) MODEL SW-20 ECOH HORIZONTAL SIDEWALL SPRINKLER(TY5332) OH Group 2(0.20 gpm/sq.-ft.) Response Coverage Minimum Minimum Deflector-To-Ceiling Sprinkler Minimum Rating Area(1), Flow(2), Pressure), Distance), Temperature Spacing(4), Ft.x Ft.(m x m) GPM(LPM) PSI(BAR) In.(mm) Rating,°F Ft.(m) Standard 16 x 16(4,9 x 4,9 51 (193) 20.7(1,43) 6 to 12(150 to 300) 155,200 8(2,4) Standard 16 x 18(4,9 x 5,5) 58(220) 26.8(1,85) 6 to 12(150 to 300) 155,200 8(2,4) Standard 16 x 20(4,9 x 6,1) 64(242) 32.7(2,25) 6 to 12(150 to 300) 155,200 8(2,4) MODEL SW-24 ECOH HORIZONTAL SIDEWALL SPRINKLER(TY5337) OH Group 1 (0.15 gpni/sq.-ft.) Response Coverage Minimum Minimum Deflector-To-Ceiling Sprinkler Minimum Rating Area(1), Flow(2), Pressure), Distance), Temperature Spacing(4), Ft.x Ft.(m x m) GPM(LPM) PSI(BAR) In.(mm) Rating,°F Ft.(m) Standard 16 x 22(4,9 x 6,7) 53(200) 22.4(1,54) 6 to 12(150 to 300) 200 8(2,4) Standard 16 x 24(4,9 x 7,3) 58(220) 26.8(1,85) 6 to 12(150 to 300) 200 8(2,4) MODEL SW-24 ECOH HORIZONTAL SIDEWALL SPRINKLER(TY5337) OH Group 2(0.20 gpm/sq.-ft.) Response Coverage Minimum Minimum Deflector-To-Ceiling Sprinkler Minimum Rating Area(1), Flow(2), Pressure), Distance), Temperature Spacing(4), Ft.x Ft.(m x m) GPM(LPM) PSI(BAR) In.(mm) Rating,°F Ft.(m) Standard 16 x 22(4,9 x 6,7) 71 (269) 40.2(2,77) 6 to 12(150 to 300) 200 8(2,4) Standard 16 x 24(4,9 x 7,3) 77(291) 47,3(3,26) 6 to 12(150 to 300) 200 8(2,4) NOTES 1.Backwall(where sprinkler is located)by sidewall(length of throw). 2.Requirement is based on minimum flow in GPM from each sprinkler.The indicted residual pressures are based on the nominal K-factor. 3.The centerline of the sprinkler waterway is located below the deflector as shown in Figures 1 and 2. 4.Minimum spacing is for lateral distance between sprinklers located along a single wall.Otherwise adjacent sprinklers(i.e., sidewall sprinklers on an adjacent wall,on an opposite wall,or pendent sprinklers)must be located outside of the maxi- mum listed protection area of the extended coverage sidewall sprinkler being utilized. TABLE A UL AND C-UL LISTING COVERAGE AND FLOW RATE CRITERIA TFP230 Page 4 of 6 Design Step 2.With pipe thread sealant ap- Frequent visual inspections are recom- plied to the pipe threads, hand tighten mended to be initially performed for Criteria • the sprinkler into the sprinkler fitting. corrosion resistant coated sprinklers, Step 3.Tighten the sprinkler into the after the installation has been complet- The TYCO Model SW-20 and SW-24, sprinkler fitting using only the W-Type ed,to verify the integrity of the corro- 11.2 K-factor, Extended Coverage Ordi- 3 (End B) Sprinkler Wrench (Ref. Fig- sion resistant coating.Thereafter, an- nary Hazard(ECOH)Horizontal Sidewall ure 3).With reference to Figures 1 and nual inspections per NFPA 25 should Sprinklers are for use in ordinary haz- 2,the W-Type 3 Sprinkler Wrench is to suffice; however, instead of inspecting and occupancies with non-combustible be applied to the sprinkler wrench flats from the floor level,a random sampling unobstructed construction and with a of close-up visual inspections should ceiling slope not exceeding 2 inches be made,so as to better determine the per foot(9.2°), using the design crite- Care and exact sprinkler condition and the long ria provided in Table A, (as well as any term integrity of the corrosion resistant additional requirements specified in Maintenance coating as it may be affected by the cor- NFPA 13 for Extended Coverage Side- rosive conditions present. wall Spray Sprinklers). The TYCO Model SW-20 and SW-24, 11.2 K-factor,Extended Coverage Ordi- A 36 inch (914 mm) clearance must nary Hazard(ECOH)Horizontal Sidewall L�m�ted be maintained between the top of the Sprinklers must be maintained and ser- sprinkler deflector and any miscella- viced in accordance with this section. Warranty neous storage. Before closing a fire protection system For warranty terms and conditions,visit The SW-20 and SW-24 may be installed main control valve for maintenance work www.tyco-fire.com. on sloped ceilings in loading docks with on the fire protection system that it con- a maximum roof slope of 4 inches per trols,obtain permission to shut down the foot (18.4°) as shown in Figure 4 and affected fire protection system from the using the design criteria provided in proper authorities and notify all person- Table A. nel who may be affected by this action. The SW-20 and SW-24 can be used only The owner is responsible for the in- for exposed applications.The SW-20 spection,testing, and maintenance of and SW-24 cannot be recessed. their fire protection system and devices in compliance with this document, as Installation well as with the applicable standards of the National Fire Protection Associa- The TYCO Model SW-20 and SW-24, tion (e.g., NFPA 25), in addition to the 11.2 K-factor, Extended Coverage Ordi- standards of any other authorities hay- nary Hazard(ECOH)Horizontal Sidewall ing jurisdiction. Contact the installing Sprinklers must be installed in accor- contractor or sprinkler manufacturer re- dance with this section. garding any questions. General Instructions Automatic sprinkler systems should be Do not install any bulb type sprinkler if inspected,tested,and maintained by a the bulb is cracked or there is a loss qualified Inspection Service in accor- of liquid from the bulb.With the sprin- dance with local requirements and/or kler held horizontally,a small air bubble national code. should be present.The diameter of the Absence of an escutcheon, which is air bubble is approximately 1/16 in.(1,6 used to cover a clearance hole, may mm). delay the time to sprinkler operation in A leak tight 1/2 inch NPT sprinkler joint a fire situation. should be obtained with a minimum Automatic sprinklers must never be to maximum torque of 7 to 14 ft.-lbs. painted, plated, coated or otherwise (9,5 to 19,0 Nm). Higher levels of torque altered after leaving the factory. Modi- can distort the sprinkler Inlet with con- fied sprinklers must be replaced.Sprin- sequent leakage or impairment of the klers that have been exposed to corro- sprinkler. sive products of combustion, but have Do not attempt to compensate for in- not operated,should be replaced if they sufficient adjustment in the Sprinkler by cannot be completely cleaned by wiping under-or over-tightening the Sprinkler/ the sprinkler with a cloth or by brushing Support Cup Assembly. Re-adjust the it with a soft bristle brush. position of the sprinkler fitting to suit. Care must be exercised to avoid dam- Step 1. Horizontal sidewall sprinklers age to the sprinklers before,during,and are to be installed with their center- after installation. Sprinklers damaged line perpendicular to the back wall and by dropping, striking, wrench twist/ parallel to the ceiling.The word "TOP" slippage,or the like, must be replaced. on the deflector is to face towards the Also, replace any sprinkler that has a ceiling. cracked bulb or that has lost liquid from its bulb.(Ref. Installation Section). TFP230 Page 5 of 6 P/N 51 - XXX - X - XXX I SPRINKLER SPRINKLER MODEL SIN FINISH TEMPERATURE RATING 072 Model SW-20 TY5332 1 Natural Brass 155 155°F(68°C) (SW-20 Only) 073 Model SW-24 TY5337 4 Signal White(RAL9003) 200 200°F(93°C) Polyester (SW-20 or SW-24) 9 Chrome Plated TABLE B PART NUMBER SELECTION MODEL SW-20 AND SW-24 ECOH HORIZONTAL SIDEWALL SPRINKLERS WITH 3/4 INCH NPT CONNECTION Ordering Procedure Contact your local distributor for avail- ability.When placing an order, indicate the full product name and Part Num- bers(P/N). Sprinkler Assemblies with NPT Thread Connections: Specify: Model (specify) ECOH Hori- zontal Sidewall Sprinkler,SIN(specify), (specify)temperature rating, (specify) finish, P/N(specify from Table B) Sprinkler Wrench: Specify:W-Type 3 Sprinkler Wrench, P/N 56-895-1-001 DE _ 14795 S.W. 7 Avenue PORTLAND, ORR 97224 PHONE 503-620-4020 INC. FAX 503-620-1058 FIRE, CCB# 64174 SPRINKLER VALVES FIRE PROTECTION CONTRACTORS POTTER ROEMER 1 MEmsER Cerritos,California mne OAiD!lCnoN Union,New Jersey14) 7 i ION .1 Flre Protection Products � J _Ili% Division of Smith Industries.Inc. \__ 0' HOSE VALVES ANGLE FEMALE X MALE DOUBLE FEMALE REGULARLY FURNISHED: Cast brass valve REGULARLY FURNISHED: Cast brass valve with red hand wheel. Female N.P.T. inlet X male hose thread with red hand wheel.Female N.P.T.inlet and outlet.300 lb.rated 0 outlet.3001b.rated o Fig. . > ❑4070 1r/z"Size c 0 4060 11/2"Size 0 4075 21/2"Size W ❑4065 21/2"Size G cbl OPTIONAL FINISHES: THREADS: r---1 it ❑—B Polished Brass 0 N.S.T. "' ❑—C Rough Chrome Plated 0 Other amik, (,' W ❑—D Polished Chrome Plated 10 s VARIATIONS: Extended stem up to 24",SPECIFY length Mite �� I g >"petcock SPECIFY location N 11 IIINip I�� MI J m Closed Open C �'_ D Female X Male shown o ✓ Sine% BCCDE � l '.1 s 11h 21A 31h 6th 71h 21h 2 cli E = 2112 31h 5 91h 111h 31h 234 LIKAIP____IA tii ALL DIMENSIONS IN INCHES (.-A 'Si 3 W ®'� ADJUSTABLE PRESSURE . Z RESTRICTING ANGLE VALVE FEMALE X MALE DOUBLE FEMALE REGULARLY FURNISHED: Cast brass valve REGULARLY FURNISHED: Cast brass valve Z with red hand wheel with pressure restricting feature. Female with red hand wheel with pressure restricting feature. Female N.P.T.inlet X male hose thread outlet.175 lb. rated.Furnished N.P.T.inlet and outlet.175 lb.rated.Furnished with field setting Z with field setting chart. chart. Fig. fig. Q ❑4060 1 th"Size ❑4090 11/2"Size L. ❑4085 21/2"Size 0 4095 2'/z"Size 0 cn W OPTIONAL FINISHES: THREADS: — cc ❑—B Polished Brass ❑N.S.T. 11= =k1 - � g ❑—C Rough Chrome Plated ❑Other ❑—D Polished Chrome Plated _• .li@ ��e �- 6- Closed Open W V Size A IICCDE D y 1th 2f/. 31h 61h 7+h 2+h 20 /{ Double Female shown 21h 31h 5 91h 111 31h 23A I j co o ALL DIMENSIONS IN INCHES E 0 AL CAST BRASS CAP WITH CHAIN. • CAST BRASS FLANGE WITH SET SCREW. Fig. Size CAP VARIATION: p-4 N. Size O.D. 0 4615 11/2" 0 With Rocker Lugs 7 of. 0 4711 11/2" 3" '' ❑ 4625 21h" ) ❑4712 21/2" 61/4" Threads: 0 N.S.T. 0 Other DATE I OPTIONAL FINISHES:0—B Polished BrassFIGURE NUMBER 1-25-90 . n—C Rnunh(lemma Platart n—D PnliahMd ChmmA Plated .r_.. r —a OPOTTER Model/Series No. ROEMER VALVES 4605-4733 FIRE PRO ACCESSORIES SERIES Member of Morris Group International^" SPECIFICATIONS CAPS Used to cover and protect male threads on valves and hydrants. Discourages entry of foreign materials. Cast brass cap with female hose thread. Pin lug and chain. 1 FLANGES '�- Used to trim pipe entry. Cast brass flange with set screw. . Y -y V''':.A' MODEL SELECTION MODEL 4630 & 4713 (Shown) CAPS PRODUCT OPTIONS ❑4605 3/4" LI 4610 1" FINISHES: (Caps) , ❑4615 1-1/2" ❑-B Polished Brass LI-C Rough Chrome Plated ID 4625 2-1/2" ❑-D Polished Chrome Plated ❑4630 3" VARIATIONS: (Caps) ❑4640 4" ❑-RL Rocker Lugs (Model 4625&4630 Only) FLANGES ❑-P Plastic ❑4711 1-1/2" ❑4712 2-1/2" ❑47133" ❑4733 3"Chrome plated stamped steel split ring flange • Call Potter Roemer sionsePmbjecttcurrent listings and - POTTER ROEMER/FIRE PRO approvals.Dimensions are subject to manufacturer's >'' FIRE EOOIPUP21 ®NFSA tolerance and may change without notice.Potter Roemer- CI; MANUFACTURERS' ASSOCIATION Headquarters: Also in: Fire Pro assumes no responsibility for use of void or "°" ^ '°^ P O.BoX 3527 New York(800)526-4592 superceded data.©Copyright Potter Roemer-Fire Pro, City of Industry,CA Chicago(800)547-3473 Member of Morris Group International""Please visit ``t 91744 U.S.A. Atlanta(800)762-0542 potterroemer.com for most current specifications. 1 t �) ASP E Los Angeles Area Miami(866)961-3473 'TrIm 800-366-3473 Dallas(866)644-3473 46054133 SERIES Date:03/27/14 NFPA® _,., ' `J ` -E 'y 626-855-4890 --��-s� www.potterroemer.corn POTTER Model/Series No. ONNECTI �S° (FDC) i\s\ ROEMER � 57�g=s734 FRE Ppa CONNECTIO E CLAPPER TYPE SERIES Member of Morris Group International.' , .. SPECIFICATIONS c u)us UL File#EX4078 0 TWO-WAY WITH SINGLE CLAPPER usren Model#S201 B APPROVED Cast brass two-way inlet body,swing clapper and pin lug swivel. Back or angle outlet as selected by model number. Lettering as selected.Size 4"x 2-1/2"x 2-1/2". TWO-WAY WITH DOUBLE CLAPPER fr Cast brass two-way inlet body,drop clappers and pin lug _ swivels. Size and outlet as selected by model number. --. • Lettering as selected. Fv MODEL 5710 (Shown) MODEL SELECTION PRODUCT OPTIONS TWO-WAY WITH SINGLE CLAPPER FINISHES: ❑5710 Back Outlet(UL Listed) 4F► ❑-B Polished Brass U 5715 Angle Outlet(UL Listed) 4 FMO. ❑-C Rough Chrome Plated Body TWO-WAY WITH DOUBLE CLAPPER ❑-D Polished Chrome Plated ❑5721 Back Outlet THREADS: ❑5722 Back Outlet U N.S.T. ❑5723 Back Outlet U Other U 5724 Back Outlet U 5731 Angle Outlet LETTERING AVAILABLE: U 5732 Angle Outlet U AUTO.SPKR. ❑STANDPIPE U 5733 Angle Outlet U 5734 Angle Outlet Note: Refer to Model Dimensional Chart for UL& FM Listing Call Potter Roamer-Fire Pro for current listings and - POTTER ROEMER/FIRE PRO approvals.Dimensions are subject to manufacturer's -- FIRE EQUIPMENT NFSA rBG MANUFACTURERS' tolerance and maychange without notice.Potter Roemer- ��, g ASSOCIATION Headquarters: Also in: Fire Pro assumes no responsibility for use of void or a° "" `°`" ` P.O.Box 3527 New York(800)526-4592 superceded data.©Copyright Potter Roemer-Fire Pro, City of Industry,CA Chicago(800)547-3473 Member of Morris Group Internationale Please visit __ a�,�o, 81744 U.S.A. Atlanta(800)762-0542 potferroemercom for most current specifications. m ��P 7�� Los Angeles Area Miami(866)961-3473 800-366-3473 Dallas(866)644-3473 5110-5734 SERIES Date: 10/20/15 NFPA® '�¢ E- 'bEMSEP . 626-855-4890 www.potterroemer.com POT TER Model/Series No. ROEMER CONNECTIONS (FDC) 5710-5734 EXPOSED FIRE DEPT. INLET FIRE PRO CONNECTIONSCLAPPER TYPE SERIES Member of Morris Group International" MODEL DIMENSIONS TWO-WAY� WITH SINGLE CLAPPER [r � � 0)ilill[ imimmi-f- 4%•10 1i 1I0. UL Listed File#EX4078 MODEL 5710 - 5715 Model#S201B 11> APPROVED TWO-WAY WITH DOUBLE CLAPPER Outlet Approvals Outlet Approvals cOus c4Lus Size A B C D Back MED Angle usmEr Model No. #EX3314 Model No. #B(3314 5721 Yes 5731 Yes 4 x 2-1/2 x 2-1/2 7-1/2 11-1/2 8-1/2 11-1/2 5722 Yes 5732 Yes 6 x 2-1/2 x 2-1/2 9-1/2 10-1/2 9 10-3/4 5723 Yes 5733 Yes 4 x 3 x 3 9-1/2 11-1/2 9-1/2 11 5724 Yes 5734 Yes 6 x 3 x 3 10 11 10-1/2 11 ennemmime j- -----F AllIW i 1 7-1/4" C -LH": 04_ , .:_, , _.,_ ...50. .., . . . , ... , .. to. / I_ . B D MODEL 5721 - 5734 UL Listed File#EX3314 Model#A105 Call Potter Roemer-Fire Pro for current listings and POTTER ROEMER/FIRE PRO approvals.Dimensions are subject to manufacturer's 'a A FIRE ERUIPMERS 0NFSA 4 tolerance and may change without notice.Potter Roemer- i MANUfATION ' ASSOCIATION Headquarters: Also in: Fire Pro assumes no responsibility for use of void or """'^""'^'°` P.O.Box 3527 New York(800)526-4592 superceded data.©Copyright Potter Roemer-Fire Pro, City of Industry,CA Chicago(800)547-3473 Member of Morris Group International'e Please visit 91744 U.S.A. Atlanta(800)762-0542 potterroemercom for most current specifications. Da \ cASPE ^ Los Angeles Area Miami(866)961-3473 800-366-3473 5110-5134 SERIES Date: 10/20/15 NFPA j y�la 626-855-4890 Dallas ro 644-3473 -...Q www.potterroemercom Bulletin 351 Rev.R CD Model D Reliabl ® Dry Ve W 4"(100mPipem)alv 6"(150mm) 1 coFeatures 1 . Differential Type...simple. . .light weight ,, construction. {: 2.Threaded in one.piece air and water seat—eases maintenance. 3. Bronze seat with "O"-Ring seals — minimizes corrosion and leakage. 4.Single hinge pin and latch design — no � ".�w complicated levers. 3 5.Simple to reset— no special tools required. ► �. �' 16.Tapered air and water seats. 7. One piece rubber facing—provides more reliable rubber-to-metal water seal. 8.Three connections styles available: ^X^ • ANSI flanged inlet and outlet • ANSI flanged inlet and grooved outlet • Metric flanged inlet and outlet The Reliable Model D Dry Pipe Valve makes pos- sible the installation of automatic sprinkler sys- tems in buildings in which freezing temperatures prevail. This type of system, called a Dry Pipe Sys- tem, has air under pressure instead of water in the Listings & Approvals piping above the dry pipe valve. When one. or more automatic sprinklers operate due to fire, the 1. Listed by Underwriters Laboratories, Inc. (UL) air pressure in the system is reduced — the dry 2. Listed by Underwriters Laboratories of Canada.(ULC) pipe valve opens and water under pressure flows 3. Certified by FM Approvals in the activated sprinkler(s)and is then distributed 4. Loss Prevention Council. (LPC, UK) on the fire. 5. NYC BS&A No. 587-75-SA. 6. Scientific Services Laboratories (SSL, Australia) 7. Conforms to EN 12259-3 (CE) The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive , Elmsford, New York, 10523 Operation Quick Opening Devices The Reliable Model D Dry Pipe Valve in its closed When an automatic sprinkler operates, the result- and open positions is shown in Figures 1 and 2. ing air pressure decay is inversely proportional to The closed position is maintained as long as the air the size of the dry system – the larger the system, pressure in the system piping above the dry pipe the slower the air pressure decays which slows the valve is sufficient to exert a greater force on the top operation of the Dry Pipe Valve. NFPA 13, Installa- side of the clapper than is exerted on its underside tion of Sprinkler Systems, specifies that quick by the pressure of the water supply. Since the area opening devices may be required in dry systems included by the air seat is approximately six times having capacities of more than 500 gallons. that of the water seat(The Differential Principle)the Reliable's Model B1 Accelerator is an approved air pressure needed to keep the dry pipe valve quick opening device that is easily attached to Reli- closed is only a fraction of that of the water supply. able's Dry Pipe Valves. The accelerator is sensitive Table 1 gives the recommended air pressure for to small drops in system pressure and it's quick op- various water supply pressures for both sizes of eration allows the system air to pass through to the Model D Dry Pipe Valves. alarm outlet and the underside of the clapper. Here Table 1 the air pressure build-up, coupled with the pres- sure of the water supply, opens the dry pipe valve Water Pressure Air Pressure psi (bar) clapper permitting the water to flow instantly to the in Supply Line psi (bar) To be Pumped into System operated sprinkler(s). Maximum Not less than Not more than Reliable's Model B1 Accelerator is described in 20 (1,38) 10 (0,68) 20 (1,37) greater detail in Bulletins 320 and 322. 50 (3,44) 15 (1,03) 25 (1,72) 75 (5,17) 20 (1,37) 30 (2,06) Valve Description 100 (6,89) 25 (1,72) 35 (2,41) 1. Rated working pressure 175 psi (12.1 bar). 125 (8,62) 30 (2,06) 40 (2,75) 2. Factory hydrostatic test pressure:350 psi(24.1 bar). 150 (10,34) 35 (2,41) 45 (3,10) 3. End and trim connections: Three valve connec- 175 (12,06) 40 (2,75) ' 50 (3,44) tion styles are available: a. US Standard Flanged Inlet and Outlet: • Flanges mate with ANSI B 16.1 (125 lb.) Flange. When one or more automatic sprinklers operate • Threaded openings per ANSI B 2.1. due to fire, the air pressure in the system piping U.S. Flange Dimensions in Inches above the dry pipe valve is reduced. The pressure I Bolt Bolt Flange of the water supply, now by exerting the greater Valve Circle Hole Outside Flange No. Size Dia. Dia. Dia. Thickness Bolts force, raises and rotates the clapper to its open po 4„ 7y 9 1x6 8 sition, permitting the water to flow to the operated 1 6,, 9/ % 11 1 8 sprinkler(s). Water also flows from the alarm outlet of the dry pipe valve through a strainer to the Reli- • Reliable's standard trim sets are compati- able Mechanical Sprinkler Alarm and Electric ble with US Flanged Valves. Alarm Switch to automatically actuate mechanical • Color— Black. b. • US Standard Flanged Inlet and Grooved Out- and electrical alarms. let (Fig. 3): Reliable Model D Dry Pipe Valves can be reset • Inlet flange mates with ANSI B 16.1 quickly and easily without the use of special tools. (125 lb.) flange. • Outlet Groove per ANSI/AWWA C606. SYSTEM AIR PRESSURE AIR INLET1 \\\\\\ \\ PRIMING l,l \ BRINING n__ __-___ WATER LEVEL FN'ATRI INLET ] _ _ CLAPPER.4 j - -__::::_1:1:1-_-___''6, /// ' PLTER SEAT �_-_-_-_- i LH ATC /- DRAIN, O _ _-at-_ __ ____________�t \\ ��" xry -- Y, imi�� ALARM OUTLET �`,�'"�d� - Ammo . �yy/�'� i ALARM TEST ' -y /ry ,I=1: o SUPPLY WATER s+cor At PRESSURE SUPPLY WATER PRESSURE Figure 1 Closed Figure 2—Open 2. U.S. Groove Dimensions in Inches The trimmings for Reliable Model D Dry Pipe Valve Outlet Groove Outlet Face Valves (Fig 4) are arranged for rapid, easy and Size Dia. Groove Dia. Width Ito Groove compact attachment and serve as connection 4" 4.500 4.334 % points to Reliable Alarm and other devices. They 1 6" 6.625 6.455 YB Y8 also serve as a means of setting and resetting the • Threaded opening per ANSI B 2.1. dry pipe valve prior to and after operation as well • Reliable's standard trim sets are compati- as allowing testing of the alarm devices without ble with US Flanged and Grooved Valves. • Color— Black. causing the system to operate. c. Metric Flanged Inlet and Outlet: The Model D Basic Trim Set is shown in Fig. 4(The • Flanges mate with EN 1092-2, electric sprinkler alarm switch is not part of the trim NF-E-29-282 and BS 4504 PN16 Flanges. set and must be separately ordered.) This trim set • Threaded openings per ISO 7/1 R. provides the air supply, drain, priming level and Metric Flange Dimensions in Millimeters alarm connections. An alarm test valve, which al- Bolt Bolt Flange I lows the alarm devices to be tested without operat- Valve Circle Hole Outside Flange Number Size Dia. Dia. Dia. Thickness Bolts ing the dry pipe valve, is included. The basic trim 100 180 18.3 229 123.8 8 set includes all items such as ball drip valves, 150 241 22.2 279 25.4 , 8 pressure gauges, etc which are needed to enable • Reliable's standard trim sets may be used pCoper dry pipe valve operation. with Metric Valves providing trim is assem The basic trim set is available in either black or gal bled carefully and extra thread sealant is vanized in one of three forms: loose, segmentally as- applied to connections between valves sembled trim or factory trimmed on the valve. and trim. Two additional trimming attachments are offered: • Color— Red. the priming chamber attachment and the fill line at- 4. Face to Face Dimension: tachment. The priming chamber attachment al- • The 4" (100 mm) Valve— 16"(406 mm) lows the priming level to be maintained while the • The 6" (150 mm) Valve— 19"(482 mmsystem remains pressurized. The fill line attach- 5. Shipping Weight: ment provides a source of water for maintaining the 6.Friction Loss Elpressed in Equivalent Length of Pipe, Valve prime level. Size Flanged Inlet Flanged Inlet The trimmings, connection, operation and main- and Outlet and Grooved tenance of the additional items which comprise a Outlet p dry pipe valve system, such as air maintenance 4" (100 mm) 120 lb. (54.5 kg) , 110 lb. (49.83 kg) devices, air compressors, accelerators, electric 6" (150 mm) 242 lb. (109.5 kg) 228 lb. (103.28 kg) alarm switches, mechanical sprinkler alarms, etc., are described in detail in the individual bulletins for based on Hazen-Williams formula with C = 120: these products. 7. Installation Position: Vertical All valves are listed and approved by Under- Size Equiv. Length writers Laboratories, Inc. and Factory Mutual 4"(100 mm) 28ft (8.51 m) Research Corp. only when used with the valve 6"(150 mm) 47ft (14.29 m) manufacturers trim sets. Trim Description 1 R 1998 AIR CONTROL VALVE CONNECTION FOR . AIR RELIEF VALVE ____/------1:INCH AUTOMATIC SPRINKLER IN MODEL D IN D.P.V ENCLOSURE PRIMING WATER VALVE DRY PIPE VALVE ryy `�) ELECTRIC ALARM . • PRESSURE SWITCH O �9 't-:-..r: y LOCATION TO MECHANICAL RELIABLE. AUTOMATIC . j , --SPRINKLER ALARM SPRINKLER CO. i•, MT.VERNON - NEW YORK `+�1, MODEL D 'BYL., LISTED �IV, t,,,N Li AVTtl4 70fiA MAIN DRAIN VALVE MMM iNCN "`' �� 4 F M D itr, ((//--���'DRY PIPE O W, �q r D ��VALVE) �- _ 175 PSI , ���� ,f lN+ PR/MJN6 TEST R IN-' �r�a;; et ELECTRIC NON-S'LENCEABLE N ALARM `• ALARM PRESSURE SWITCH �\ 175 PSI �S/FGoaB �. LOCATION D7PG65B 1 7En ALARM TEST VALVE SAN BALL DRIP VALVE 351E103 I Figure 3 Figure 4—Model D Dry Pipe Valve Model D Basic Trimming 3. Ordering Information Specify . • Valve Size: Either 4"(100 mm) or 6"(150 mm). • Style of Trim - Loose Individual part trim or seg- When size is specified in mm, a metric valve mentally assembled trim or factory trimmed per 3(c) will be supplied. valve. • Inlet and Outlet Connection — Either • Additional Equipment—Air Maintenance De- Flanged/Flanged or Flanged/Grooved. vices, Air Compressors, Accelerators, Electric • Trim - Basic Trim Sprinkler Alarm Switches and Mechanical Priming Chamber Attachment Sprinkler Alarms must be separately ordered. Fill Line Attachment • Galvanized or Black Trim. Installation Measurement in Inches Valve A B C D E F G H I J 4" (100mm) 16 6% 5 17 10 11 15 4% 2% 3% 6" (150mm) 19 8% 6% 18% 11% 11 15% 4% — 3% Installation Dimensions of 4" (100mm) & 6" (150mm) sizes h"---- B / • ao :o � ao ! w' ' 1 f C i a 11101110.45M ' �_. 1998 I-: m, 4INCH I,I C7 �' l:'I MODEL D 1Jm� _ —OOO PIPED VALVE 111.111011111i•II���III o LE .I �_ A / RELIABLE AUTOMATIC 0 .. I SPRINKLER irC ° Y'Bv�y ®LISTED Y°[i IOTA '` _ '� '"iaPN01 QdFMD0 Y� ����� iij Ir-1� _ 0 o ■ RMI. ���i�=� f 1 T 1 ��: r _I*I_111 t .. I III t F -- H i D G 350D/M The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances,whenever applicable. Products manufactured and distributed by RELIABLE have been protecting life and property for over 80 years,and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States,Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. .= Recycled PaP er ReIiabIö800.431.1588 Sales Office 800.848.6051Fax Sales Fax 914.829-2042 Corporate Office Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address PG. Printed in U.S 10/06 P/N 9999970045 �AR�QN EL P1PE.... FIR QTJ QTEQN l!4 S e • • ::.# ,z.. Fire cus LPCB cE vds See Victaulic publication 10.01 for details SERIES 705W WITH WEATHERPROOF ACTUATOR FOR 300 PSI SERVICE • The Series 705W butterfly valve features an approved weatherproof actuator housing r approved for indoor or outdoor use. It has a ductile iron body and disc with EPDM disc coating.The body is coated with a heat fused polyphenylene sulfide blend to meet FM requirements. Designed for fire protection services only,Series 705W valve is UL Listed and FM Approved for 300 psi/2065kPa service.Contact Victaulic for details of agency approvals. WEATHERPROOF ACTUATOR • Supervisory switches that monitor the valve in the fully open or fully closed position for valves are available 21 — 12"/65-300mm pre-wired (PW). OPTIONAL SUPPLY-SIDE TAP Series 705W valves are available with a 1/2" (for 21/2", 76.1 mm and 3"sizes)or 1/4' (4 12"/100—300 mm sizes) NPT supply side tap designed to allow direct water supply connection to Victaulic FireLock actuated fire protection valves. See separate drawings below.This is an optional feature and must be clearly noted on all orders. 1/4"tap avail- able by special order. Contact Victaulic for additional information on tapped valves. MATERIAL SPECIFICATIONS Body: Ductile iron conforming to ASTM A-536,coated with polyphenylene sulfide blend. Disc: Ductile iron conforming to ASTM A-536,various grades, EPDM coated. Disc Coating: • Grade"E" EPDM EPDM (Green color code). Temperature range—30°F to+230°F/-34°C to+110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids,oil-free air and many chemical services. UL classified in accordance with ANSI/NSF 61 for cold+86°F/+30°C and hot+180°F/+82°C potable water service. NOT RECOMMENDED FOR PETROLEUM SERVICES. Stem Bearings:Teflon impregnated fiberglass with stainless steel backing. Stem Bearing Nuts:Type 416 Stainless Steel. Tap Plug:Carbon steel, plated. 0-Ring: EPDM Bracket:Carbon steel, painted. Actuator: • 21/ —8"/65—200 mm: Bronze traveling nut on a steel lead screw, in a ductile iron housing. • 10—12"/250—300mm: Steel worm and cast iron quadrant gear, in a cast iron housing. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2006 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. �('tcal.Jl1(2° 7 rr 552 1 IPS CARBON STEEL PIPE—FIRE PROTECTION VALVES ireLo kButterfly Valve SERIES 705W WITH WEATHERPROOF ACTUATOR FOR 300 PSI SERVICE MATERIAL SPECIFICATIONS Handwheel: Size Version cULus,LPCB,FM Mack VdS* Inches inches Red mm mm mm 21/2 4 3.0 25 65-100 76.2 5-6 4.5 200 125-150 114.3 $ 160 mm 250 200 10-12 9 250-300 225 *VdS version not UL Listed,FM Approved or LPCB Approved. www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2006 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA �CtaUlIC° in 14 acv C IPS CARBON STEEL PIPE• FIRE PROTECTION VALVES 1 U, 1 o re ock® Butterfly Valve SERIES 705W WITH WEATHERPROOF ACTUATOR FOR 300 PSI SERVICE DIMENSIONS- c®us ® LPCB Aprx.Wgt. Size Dimensions-inches/millimeters Each Nominal ActualOutside Size Diameter inches inches End to End Hgt. mm mm .A «&� E . 'J "0" "N"t ,gyp„8 Lbs/kg 2'// I 2.875 3.77 8.76 4.21 6.08 3.00 0.00* 0.75 8.3 65 73.0 95.6 222.5 106.9 154.4 76.2 0.0* 19.1 3.8 76.1 mm 3 000 3.77 8.76 4.21 6.08 3.00 0.00* 0.75 8.3 I 76.1 95.6 222.5 106.9 154.4 76.2 0.0* 19.1 3.8 3 3.500 3.77 9.40 0.08 4.2' 6.08 3.00 0.00* 0.75 8.9 80 88.9 95.6 238.8 2.0 106.9 154.4 76.2 0.0* 19.1 4.0 4 4.500 4.63 10.84 0.07 6.01 6.98 3.00 0.73 1.13 14.9 100 114.3 117.6 275.3 1.8 152.7 177.3 76.2 18.5 28 7 6.8 39.7 mm 5.500 5.88 12.38 0.43 6.01 8.57 4.50 21.0 139.7 149.4 314.5 10.9 152.7 217.7 114.3 9.5 5 5.563 5.88 12.38 0.43 6.01 8.57 4.50 21.0 125 i 141.3 149.4 314.5 10.9 152.7 217.7 114.3 9.5 65.1 mm 6.500 5.88 13.41 1.00 7.51 9.32 4.50 1.60 1.88 26.5 165.' 149.4 340.6 25.4 190.8 236.7 114.3 40.6 47.8 12.0 6 6.625 5.88 '1341 1.00 7.51 9.32 4.50 '.60 1.88 26.5 150 168.3 1494 340.6 25.4 190.8 236.7 114.3 40.6 47.8 2.0 8 8.625 5.33 16.50 1.27 9.65 10.98 6.30 0.00* 0.68 43.0 200 219.1 135.4 4'9.- 32.3 245.1 278.9 1.60.0 0.0* 17.3 '9.5 10 10.750 6.40 1914. 1.72 12.20 16.19 9.00 80.0 250 273.0 162.6 486.2 43.7 309.9 411.2 228.6 36.3 12 12.750 6.50 21.54 2.66 14.25 17.22 9.00 102.0 300 323.9 165.1 547", 67.6 362.0 437.4 228.6 46.3 *On Centerline t These dimensions apply only to a Series 705W Butterfly Valve with a 1/2-inch NPT,supply-side tap 1.To prevent rotation of valves.it is recommended that Series 705W be installed with Victaulic Style 07 Zero-Flex,Style 005 FireLock,Style 009/009V FireLock EZ,or Style HP-70 Rigid Couplings.If Victaulic flexible couplings are used.additional support may be required. 2.Valve must not be installed with disc in full open position.Disc must be partly closed so that no part is protruding beyond end of valve body. 3.Victaulic grooved end butterfly valves are permitted for use with grooved end pipe(IPS)only.Not permitted for use with plain end(IPS)pipe. 4.Series 705W valves are designed for ambient weather conditions as opposed to submersible service. Ir _ II .rten. I irmt_ - MAIM II lialin M�►. . _ l'i pi i�Supply Tap\ I 4, ':"NT ‘-i 1 iir- sJo' Ta IIIA. I �:� Wir- ISI ill � � 1._Ga liill N i� �� �,i�ii, II - F � F LL � - AJ L P 21-4-INCH/65-100-MM SIZES 5-12-INCH/125-300-MM SIZES www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2006 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. ictaulic` 1n 1Q IPS CARBON STEEL PIPE- FIRE PROTECTION VALVES 1.U. .1.6 reLoc • Butterfly Valve SERIES 705W WITH WEATHERPROOF ACTUATOR FOR 300 PSI SERVICE DIMENSIONS- (VdS) Aprx.Wgt. Size Dimensions-inches/millimeters Each Nominal Actual Outside Size Diameter inches inches End to End Mgt. mm mm "A" "B" "E" "F" 'J" "D" 1 "N"4 I "P"#, 1bslkg 2'/z 2.875 3.77 8.76 4.21 6.08 4.92 0.00* 0.75 8.3 65 73.0 95.6 222.5 1069 154.4 125 0.0* 19.1 3.8 76.1 mm 3.000 3.77 8.76 _ 4.21 6.08 4.92 0.00* 0.75 8.3 761 95.6 222.5 106.9 154.4 125 0.0* 19.1 3.8 3 3.500 3.77 9.40 0.08 4.21 6.08 4.92 0.00* 0.75 89 80 88.9 95.6 238.8 2.0 106.9 154.4 125 0.0* 19.1 4.0 4 i 4.500 4.63 10.84 0.07 6.01 6.98 4.92 0.73 1.13 14.9 100 114.3 117.6 275.3 1.8 152.7 177.3 125 18.5 28.7 6.8 39.7mm 5.500 5.88 12.38 0.43 6.01 8.57 7.87 210 139.7 149.4 314.5 10.9 152.7 217.7 200 9.5 5 5.563 5.88 12.38 0.43 6.01 8.57 7.87 _ 21.0 125 141.3 149.4 314.5 10.9 152.7 217.7 200 9.5 65.1 mm 6.500 5.88 13.4' 1.00 7.51 9.32 7.87 1.60 1.88 26.5 165.1 149.4 340.6 25.4 190.8 236.7 200 40.6 478 12.0 I 6 6.625 5.88 13.41 1.00 7.51 9.32 7.87 1.60 1 88 265 150 ^tl 168.3 149.4 340.6 25.4 190.8 236.7 200 40.6 47.8 12.0 8 I 8.625 5.33 16.50 1.27 9.65 10.98 9.84 0.00* 0.68 43.0 200_ 1 219.1 135.4 419.1 32.3 245.1 278.9 250 0.0* 173 19.5 10 10.750 6.40 1914. 172 12.20 16.19 9.84 80.0 250 273.0 162.6 486.2 43.7 309.9 411.2 250 36.3 12 i 12.750 6.50 21.54 2.66 14.25 17.22 9.84 102.0 300 323.9 165.1 547.' 67.6 362.0 4374 250 46.3 ' *On Centerline #These dimensions apply only to a Series 705W Butterfly Valve with a 1/2-inch NPT,supply-side tap 1.To prevent rotation of valves.it is recommended that Series 705W be installed with Victaulic Style 07 Zero-Flex®.Style 005 FireLock,Style 009/00W FireLock EZ,or Style HP-70 Rigid Couplings.If Victaulic flexible couplings are used,additional support may be required. 2.Valve must not be installed with disc in full open position.Disc must be partly closed so that no part is protruding beyond end of valve body. 3.Victaulic grooved end butterfly valves are permitted for use with grooved end pipe(IPS)only.Not permitted for use with plain end(IPS)pipe. 4.Series 705W valves are designed for ambient weather conditions as opposed to submersible service. 1 i , _ .1.ii,ts....- A. ErealPilliliri'le °, LLA „� i i II i 1/2��NPT -_ B �F"NFT I �q Supply Tap * 41: Supply Tap itil MIL.' GIS il �� N- I -� !fir II II' r II N I I " r F A �E L-A E 21-4-INCH/65-100-MM SIZES 5-12-INCH/125-300-MM SIZES • www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2006 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA.. ictaulic°--- 1 f11p A IJ C11 C IPS CARBON STEEL PIPE - FIRE PROTECTION VALVES .1.U. J.t$ Firs f rock® Butterfly Valve SERIES 705W WITH WEATHERPROOF ACTUATOR FOR 300 PSI SERVICE PERFORMANCE The chart expresses the frictional resistance of Victaulic Series 705W in equivalent feet/meters of straight pipe. Size Size Actual Actual Nominal Outside Nominal outside Size Diameter >;,` -Equiv. Sim Diameter Equiv.` Inches Inches feet/m Inches F inches Feet/m mm mm of Pipe mm mm of Pipe 212 2.875 5 65.1 mm 6.500 8 65 73.0 1.6 165.1 2.5 J 76.1 mm 3.000 5 6 6.625 8 76.1 1.6 150 168.3 2.5 3 3.500 5 8 8.625 1 80 88.9 1.6 200 219.1 3.4 4 4.500 12 10 10.750 12 100 114.3 3.7 250 273.0 3.7 39.7 mm 5.500 12 12 12.750 14 139.7 3.7 300 323.9 4.3 5 5.563 12 125 141.3 3.7 www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY©2006 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. ,CtauIic` ory r rn io r IPS CARBON STEEL PIPE- FIRE PROTECTION VALVES 1 U, 1 o r m _.cbutterfly Valve SERIES 705W WITH WEATHERPROOF ACTUATOR FOR 300 PSI SERVICE PERFORMANCE Cv values for flow of water at+60°F/+16°C with a fully open valve are shown in the table below. For additional details,contact Victaulic. Formulas for Cv Values: OP = Q2 Where: C z Q=Flow(GPM) AP=Pressure Drop(psi) Q = C x AP Cy=Flow Coefficient Size Cv Size Cv Size Cv Actual Actual Actual Nominal Outside Nominal Outside Nominal Outside Size Diameter Size Diameter • Size Diameter Inches • Inches Inches Inches Inches Inches mm mm (Full Open) mm mm (Full Open) mm mm (Full Open) 21/2 2.875 5.500 8 8.625 65 73.0 325 139.7 mm 139.7 1150 200 219.1 3400 76.1 mm 3.000 325 5 5.563 1150 10 10.750 5750 76.1 125 141.3 250 j 273.0 3 3.500 6.500 12 12.750 8300 482 165.1 1850 80 88.9 mm i 165.1 300 ' 323.9 4 4.500 600 6 6.625 850 100 1'4.3 10 168.3 Formulas for Kv Values: AP = Q2 Where: K Q=Flow(t) Q = K, xAP AP=Pressure(bar) K =Flow Factor Size K2 Size K2 Size Ki, Actual Actual Actual Nominal Outside Nominal Outside Nominal Outside Size Diameter Size Diameter Size Diameter Inches Inches Inches Inches Inches inches mm mm (Full Open) mm mm (Full Open) mm mm (Full Open) 21/2 2.875 280 139.7 mm 5.500 995 8 8.625 2940 65_._,.__... 73.0 139.7 200 . 219.1 76.1 mm 3.000 280 5 5.563 10 1 10.750 76.1 125 141.3 995 250 273.0 4975 3 3.500 6.500 12 12.750 80 - 88.9 415 65.1 mm 165.1 1600 300 323.9 7180 4 4.500 6 6.625 100 114.3 520 150 168.3 1600 www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY©2006 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. ictaulic° 1r11P a rc i c IPS CARBON STEEL PIPE— FIRE PROTECTION VALVES 1 U. j ö Fit Lock°, Butterfly Valve SERIES 705W WITH WEATHERPROOF ACTUATOR FOR 300 PSI SERVICE SWITCH AND WIRING 1. The supervisory switch contains two,single pole, double throw, pre-wired switches. 2.Switches are rated: 10 amps @ 125 or 250 VAC/60 Hz 0.50 amps @ 125 VDC 0.25 amps @ 250 VDC 3.Switches supervise the valve in the 'open" position. 4.One switch has two#18 MTW wires per terminal,which permit complete supervision of leads (refer to diagrams and notes below).The second switch has one#18 MTW wire per terminal. This double circuit provides flexibility to operate two electrical devices at separate locations, such as an indicating light and an audible alarm, in the area that the valve is installed. 5.A#14 MTW ground lead (green)is provided. Switch#1 =S1 For connection to the supervisory circuit of a UL Listed alarm control panel Switch#2=S2 Auxiliary switch that may be connected to auxiliary devices, per the authority having jurisdiction Normally Closed: (2) Blue S1 Common: (2)Yellow Normally Closed: Blue with Orange Stripe S2 Normally Open: Brown with Orange Stripe Common: Yellow with Orange Stripe ,T PPM NP T�F\ '�H\E RESISTOR,COeTEOL PA\EL 6F fxT I� <Uf'ERVI5OAY DICATTR CIRCUIT C ►�♦« �'��Il� MEI s AVD <, c BEOR eolT sr ,uRCE Switch 1:2 leads per terminal Switch Z:1 lead per terminal NOTE:The above diagram shows a connection between the common terminal(yellow—51 and yellow-with-orange stripe—S2)and the normally closed terminal (blue—S1 and blue-with-orange stripe—S2). In this example,the indicator light and alarm will stay on until the valve is fully open. When the valve is fully open,the indicator light and alarm will go out.Cap off any unused wires (e.g. brown with orange stripe). Only S1 (two leads per terminal)may be connected to the fire alarm control panel. The connection of the alarm switch wiring shall be in accordance with NFPA 72 and the auxiliary switch per NFPA 70(NEC). www.victaulic.com vICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2006 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. ictaulac' nn1 c 1(1 14 '7 P$C .N STIr FIRED TECTI?N I I S i FireLock® Butterfly Valve SERIES 705W WITH WEATHERPROOF ACTUATOR FOR 300 PSI SERVICE WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications.designs and standard equipment without notice and without incurring obligations. INSTALLATION Reference should always be made to the installation sheet included with the valve.Verify you have the latest revision by visiting our website at www.victaulic.com. Further reference can be found in the I-100 Victaulic Field Installation Handbook. III 11 111 10 I III IIIIIII 111111IIII II111111III WCAS-6LU PQL For complete contact information,visit www.victaulic.com 10.18 2466 REV F UPDATED 12/2006 CtaUliC® VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2006 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. In 14 IPS CARBON STEEL PIPE-FIRE PROTECTION VALVES 10.08 VICTAULIC'I IS AN ISO 9001 CERTIFIED COMPANY Series 717 FireLock® Check Valves PRODUCT DESCRIPTION Series 717 FireLock check valve is a CAD-developed design that is hydrodynamically efficient.A totally rubber encapsulated disc on 4 - 12" (100- 300 mm) sizes provides superior corrosion resistance. This single disc design incorporates a spring assisted feature for non-slamming operation. For systems requiring a Riser Check option refer to section 10.09. The 4" (100 mm) and larger sizes are provided with upstream and downstream drains and a welded-in ® ® nickel seat design. All sizes of Series 717 can be installed in the vertical or horizontal position to provide ''' leak-free sealing under conditions as low as five feet of head. Each valve is factory tested to 500 psi See Victaulic (3440 kPa).The 21/2 and 3"(65 and 80 mm)sizes are UL/ULC Listed and 4"(100 mm)sizes and larger are publication 10.01 UL/ULC Listed and FM Approved for services up to 250 psi(1725 kPa).Sizes 4-8'/100-200 mm(except Sizes 21/2-3" for details. 165,1 mm size) are VdS approved. Grooved ends allow fast, easy installation with just two Victaulic couplings or the valve may be mounted If to flanged (ANSI CL.150)equipment using either to Victaulic Style 741 Vic-Flange®or Style 744 FireLock '' - flange adapters on either end. 1\- 0 6) -kitio ,1 See Victaulic publication 10.01 for details. Sizes 4-12" DIMENSIONS A-1 rB ) Valve Size Dimensions-Inches/millimeters Actual Outside Approx.'Q Wgt.Ea. II1I 0 Nominal iameter Diameter E to E Lbs. Inimm Infmm A B C D E J K P R kg Typical 21/2-3" 21/2 2.875 3.88 4.26 3.57 - - - - - - 3.6 65 73,0 99 108 91 - - - - - - 1,6 76,1 mm 3.000 3.88 4.26 3.57 - - - - 3.6 76,1 99 108 91 - - - - - - 1,6 RA > 3 3.500 4.25 5.06 4.17 - - - - - 4.5 R I� 80 88,9 108 129 106 - - - - - - 2,0 4 r4 t 4.500 9.63 6.00 3.88 2.75 3.50 2.00 4.50 3.50 3.35 20.0 P ' -f 100 1143 245 152 99 70 89 51 114 89 85 91 I D E 525 5.563413 10.502 6.80173 4.501 _4 4.17 2555 5.88 4.008 3.4 0981 27.01 1-K--> © I 139,7 mm t 5.500 10.50 6.80 4.50 - 4.17 2.15 5.88 4.08 3.98 27.0 <-B--> ->1 J k- 0 139,7 267 173 114 - 106 55 149 104 101 12,3 CD >"NPT Upstream Drain 6 t 6.625 11.50 8.00 5.00 - 4.50 2.38 6.67 4.73 3.89 38.0 OO '/z"NPT Downstream Drain 150 168,3 292 203 127 - 114 61 169 120 99 17,2 OO 2"NPT(Drain Optional) 6.500 11.50 8.00 5.00 - 4.50 2.38 6.67 4.73 3.89 38.0 165,1 mm 165,1 292 203 127 - 114 61 169 120 99 17,2 Typical 4-8" 8 1 8.625 14.00 9.88 6.06 5.05 5.65 2.15 8.85 5.65 5.75 64.0 200 219,1 356 251 154 128 144 55 225 144 146 29,0 A 1 10 10.750 17.00 12.00 7.09 5.96 6.69 2.15 10.92 6.73 - 100.0 250 273,0 432 305 180 151 170 55 277 171 - 45,4 ��u 1+1 IIIIi I C 12 12.750 19.50 14.00 8.06 6.91 7.64 2.51 12.81 7.73 - 140.0 O III �I300 323.9 495 356 205 176 194 64 925 196 - 63,5 D E t VdS Approved K ©' '0 ®'/i"NPT Upstream Drain 0'/"NPT Downstream Drain Typical 10-12" ®REGISTERED TRADEMARK OF VICTAULIC-0 COPYRIGHT 2004 VICTAULIC-PRINTED IN U.S.A.-SKU#WCAS-66VPXF 1479 REV F Victaulic Company of America•Phone:1-800-PICK-VIC(1-800-742-5842)•Fax.610-250-8817•e-mail:pickvic@victaulic.com Victaulic Company of Canada•Phone:905-884-7444•Fax:905-884-9774•e-mall:viccanada@victaulic.com Victaulic Europe•Phone:32-9-381-1500•Fax:32-9-380-4438•e-mail:viceuro@victaulic.be Victaulic America Latina•Phone:610-559-3300•Fax:610-559-3608•e-mail:vical@victaulic.com ,Cta u',C® Victaulic Asia Pacific•Phone:86-21-58855151 •Fax:86-21-58851298•e-mail:vicap@victaulic.com 10.08 FLOW CHARACTERISTICS NOTE:Placement of check valves too SERIES 717 close to sources of unstable flow will shorten the life of the valve and 6.0 potentially may damage the system 5.0 —FLOW OF WATER To extend valve life,valves should be 4.0 -AT 60°F(16°C) installed a reasonable distance THROUGH VALVE downstream from pumps,elbows, lir. expanders,reducers fi other similar 3.0 Si far..devices.Sound piping practicesdictate a minimum of five(5)timeso�• the pipe diameter for general use. 2.0 t. �. Distances between three(3)and five • r rot V r (5)diameters are allowable provided Vj � the flow velocity is less than eight(8) 0- feet per second(2.4 mps).Distances less than three(3)diameters are not f1 1.0 recommended and will violate the 0. 0.9 Victaulic product warranty. Lt 0.8 0.7 w 0.6 0.5 u) 0.4 ix 0.3 a 0.2 0.1 10 20 30 40 60 80 100 200 300 400 600 1,000 2,000 4,000 6,000 10,000 20,000 800 3,000 8,000 FLOW RATE-G.P.M. MATERIAL SPECIFICATIONS Body: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. 21/2-3"(65-80 mm) sizes PPS coated, 4- 12" (100- 300 mm) sizes painted black enamel. Body Seat: 21/2- 3" (65-80 mm) sizes PPS coated. 4 - 12"(100- 300 mm) integrally welded on nickel alloy. Disc Seal or Coating: • Grade"E" EPDM EPDM(Green color code).Temperature range-30°F to+230°F(-34°C to+110°C). Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids,oil-free air and many chemical services.UL classified in accordance with ANSI/NSF 61 for cold+86°F(+30°C) and hot+180°F (+82°C) potable water service. NOT RECOMMENDED FOR PETROLEUM SERVICES. *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Discs: 21/2-3" (65-80 mm) Aluminum bronze conforming to ASTM B-148 with Grade"E"Seal. 4 - 12" (100- 300 mm)ductile iron conforming to ASTM A-536, grade 65-45-12,fully encapsulated in Grade"E"elastomer. Shaft: 21/2-3" (65 -80 mm) Type 416 stainless steel. 4- 12" (100-300 mm)Type 316 stainless steel. Spring:All sizes Type 302/304 stainless steel. Shaft Plug:21/2-3"(65-80 mm)only;SAE Hex Socket Type conforming to ASTM A-576,cadmium plated to military specifications QQ-P-416A,class 3 type 2.4-12"(100-300 mm)only;carbon steel zinc plated to ASTM B-633. Pipe Plug: 4- 12'(100- 300 mm)only; carbon steel zinc plated to ASTM B-633. This product shall be manufactured by Victaulic Company.All products shall be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. 2 Series 717 FireLock® Check Valves ES-FP53L For Fire Protection Applications Job Name Contractor Job Location Approval Engineer Contractor's P.O. No. Approval Representative No. FP53L 1/211 Pressure Relief Valve Set 175 psi .27 i6 ® Underwriters Laboratory listed R _ — 1/2" NPT Female Watts No. FP53L is designed for use in fire protection grid sys- Outlet tems to provide protection against excessive water pressure caused by thermal expansion or line surge. It has a standard 175 psi pressure relief setting and can be installed horizontally or vertically. Bronze body construction with stainless steel r tiF spring to inhibit corrosion. The valve is constructed with a pre- cision re cision stem guide to ensure proper reseating. The test lever af- fords periodic manual testing and flushing of waterways and seating surfaces. 1/2" NPT FEATURES Male I Underwriters Laboratory listed Outlet I Forged stainless steel spring I Bronze body construction for superior strength and to prevent corrosion 1 Manual test lever I' Valve stem is guided to enhance reseating UL 111, o 1/2"male inlet x female outlet 1' 175 psi pressure setting DIMENSIONS/WEIGHT No. Size I Height Width Weight Pressure Relief Valves should be tested FP53L 1h" I 31/2. 17/8" 1/2 lb. periodically to ensure that the product has not been affected by corrosive water conditions and to ensure that the valve and discharge SPECIFICATIONS piping have not been altered or tampered with. For applications requiring a UL approved relief valve to provide pressure relief protection from water pressure in excess of 175 psi. Each valve shall be bronze body construction with forged stainless steel spring. It shall have a test lever and the valve shall be guided to enhance reseating and to decrease chance of A LEADER iN VALVE TECHNOLOGY the seat being misaligned. Watts Regulator Company Model `WA ® No. FP53L "I Watts product specifications in U.S.customary units and metric are approximate and are ' REGULATOR provided for reference only. For precise measurements,please contact Watts Technical -Since 1874 Watts Industries,Inc.— Service. Watts serves the right to change or modify product design, construction, Water Products Division•Safety&Control Valves specifications,or materials with out prior notice and without incurring any obligation to USA:815 Chestnut Street,North Andover,MA 01845-6098 make such changes and modifications on Watts products previously or subsequently sold. Canada:5435 North Service Road,Burlington,Ontario L7L 5H7 Series B-6000-UL/B-6001-UL No. FS10-F Waterflow Detectors for Fire 2-Piece, Bronze, Standard Port Ball Valves Protection sprinkler Service No.FS10-F No.B-6001 Waterflow detectors provide a positive way of indicat- x'• 3/8"-2" ing the flow of water in any distribution, branch or No.B-6000A. Solder Ends mainline piping of a sprinkler system. Underwriters 1/4"-2" *Al1 Laboratories listed for automatic sprinkler protection IiiiLiky, Threaded Ends service and signalling systems in branch piping or mainline sprinkler systems. It immediately indicates the location of an open head(s). a' • Sizes '/4"- 1/2"and 11/4"- 2" have Durafill seats (carbon/ For pipe size 1", 11/4"or 11/2"using standard ASTM tees. glass-filled PTFE); sizes 3/4" and 1" have Uniseal seats Factory set and sealed for a minimum alarm flow rate of 4 (enhanced PTFE). to 10 gpm. • Electroless Nickel plated brass ball Max. pressure 175 psi,Max.temperature 300°F. 1"NPT connection. • Sizes /4"-2"pressure rated at 600 WOG and 150 WSP Weight 2.5 lbs. • Adjustable stem packing gland 0 Llsted/ilFM IP-Approved • Temperatures from 0°to 450°F (-18°to 232°C)at 50 psi No. FS10 FL with indicator light. (3.4 bars)for Durafill/Uniseal seats,and 0 to 350°F(-18° •Paddle adaptable for 1", 11/4"or 11/2"pipe p to 177°C)at 50 psi(3.4 bars)for Virgin PTFE. • High and low sensitivity adjustment •Single cover retainer screw For additional information,send for F-FS10-F. Models:B-6000-UL U.L.fire protection 1/4"-2"-HFVFX WATTS B-6000-UL ACV automatic control valves Dimensions(Inches) Weight For waterworks, commercial, irrigation,fire protection systems and H— Size C H I L lbs.1/4 13/4 31/16 3/6 21/,6 .6 controls. Watts ACV manufactures automatic control valves to solve a wide variety of fluid control problems. Pace-setting •.•• 3/8 13/4 31/16 3/8 21/16 .6 features include our exclusive, positive-closure �,� 1/2 13/4 33/4 1/2 21/4 .6 QUAD RING SEAT SEAL, a non-edged seat, 'It` """".�.,. 3/4 2 33/4 11/16 213/16 1.0 9 illi�'ur 1 21/4 a1/2 1/a 3'/16 1.6 and a high-protection, FDA apporved, .�` . 1 I 21/2 ,3 , FUSED epoxy finish. In-line maintenance - . gi111 Illi 11/4 3 h6 1 3/a 2.2 P Y iriZ11- ti 11 3 51/2 11/4 41/4 3.2 is minimal. Sizes range from 11/4" - 16" - t . L---1 2 35/16 51/2 11/2 413/16 4.9 globe pattern and 11/4"-12"angle pattern. 141; qf 8-6001-UL End connections in threaded, grooved and 4r " 3/8 11/2 33/4 3/8 25/16 .5 flanged. Main valve materials are available in 1/2 13/4 33/4 1/2 23/8 .6 cast iron, ductile iron,steel,aluminum, bronze and aluminum 3/4 2 33/4 11/16 3°/16 1.1 bronze. Pilot operated, diaphragm actuated,the valve is capable of 1 21/2 41/2 7/e 33/4 1.4 numerous functional combinations. 11/4 21/2 313/16 1 41/2 2.0 For additional information,send for C-CACV. 11/2 3 51/2 11/4 5 3.3 2 35/16 51/2 11/2 '61/4 5.2 —H— T For additional information,send for ES-86000. I I Series 408-OSY-RW Iron Flanged OS&Y I 9 F E Gate Valves For Water Service v ASTM A126 Class B Iron gate valves. 250 psi CWP non-shock. Max. Temp. 140°F y, Std.Tap Sizewll ') 1k";21/2-4 C Series 408-0SY-RW * 3/4";6"-12" =. Plisfitti14, . Sizes 21/2" 12" Q , ..v—.ma B— _ G No.& Numff D size of 1316.1 Class Resilient wedge disc design, �A— bolt holes d2i5l Std. epoxy coated for additional m9 corrosion resistance. 4`,`, Dimensions Weight Size A BCDE F G H lb. • Easy in-line service EI 21/2 71/ 33/4 7 11/56 137/8 163/e 4-5/e 71/4 55 • Full port flow- low head loss 3 8 4 71/2 3/4 15% 187/8 4-3/4 10 70 1 4 4 9 41/2 9 15/16 181/4 223/4 8-5/8 10 100 la Listed/ FM No-Approved 4 6 101/2 51/4 11 1 233/4 301/8 8-3/4 12 150 8 111/2 53/4 131/2 11/8 291/4 373/4 8-3/4 14 250 10 13 61/2 16 13/16 353/8 453/4 12-7/8 18 400 12 14 7 19 11/4 405/8 531/8 12-1/e 18 580 A LEADER /N VALVE TECHNOLOGYUSA:815 Chestnut Street,North Andover,MA 01845-6098 `WA ® Canada:5435 North Service Road,Burlington,Ontario L7L 5417 www.wattsreg.com REGULATOR ��9�001 —Since 1874 Watts Industries,Inc.— I CERTwED Water Products Division•Safety&Control Valves ES-FP53L 9840 ©Watts Regulator Co.,1998 Printed in U.S.A. 14795 Aven DELTZ „, S.W. 72ndR ue PORTLAND, OR 97224 PHONE 503-620-4020 INC. N C. FAX 503-620-1058 FIRE CCB#64174 SWITCHES & BELLS FIRE PROTECTION CONTRACTORS MODEL PS10A P POTTER PRESSURE SWITCH The Symbol of Protection UL and CSFM Listed,FM and LPC Approved,NYMEAAccepted,CE Marked Dimensions: 4 3/4"(12,1 cm)W x 2 1/4"(5,7cm)D x 4 3/8"(11,1 cm)H Enclosure: Cover-Die-cast with textured red powdercoat finish Base-Plated Steel Pressure Connection:1/2"NPT Male ()POTTER 1.0611 Factory Adjustment: St.Louis,Missouri CE Operates on Pressure increase at6±1 PSI(0,41±0,07 BAR) ModelOISVJ Operates on Pressure decrease at 5±1 PSI(0,35±0,07 BAR) •'�°� PS10-1A :•~° Q Maximum Differential: 1 PSI(0,06 BAR) Maximum System Pressure: 250 PSI(17,2 BAR) Switch Contacts:SPDT(Form C) ( = 15.0Ampsat125/250VAC,2.5Ampsat30VDC + One set in PS 10-1 A,Two sets in PS 10-2A Environmental Specifications: Indoor or outdoor use NEMA4/IP55 Rated Enclosure-when used with proper conduit fittings Temperature range:-40°F to 140°F(-40°C to 60°C) (Not for use in hazardous locations) Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D PS10-1A Single Switch-Stock No. 1340101 Residential Occupancy up to four stories NFPA-13R PS10-2A Double Switch-Stock No.1340102 National Fire Alarm Code NFPA-72 Tamper:Cover incorporates tamper resistant fasteners that require a special key for removal.One key is supplied with each device.For optional cover tamper switch kit,order Stock No.0090134. INSTALLATION AND TEST PROCEDURES installed on the alarm outlet side of the retard chamber of the sprinkler The Potter PSI OA Series Pressure Actuated Switches are designed for system. the detection of a waterflow condition in automatic fire sprinkler systems TESTING: Accomplished by opening the inspector's end-of-line test of particular designs such as wet systems with alarm check valves or valve.Allow time to compensate for system or control retard. dry pipe systems.They may also be used to provide a low pressure supervisory signal. They may be adjusted to operate on pressure CAUTION: Method 2 is not applicable for remote station service use, between 4 and 20 PSI(0,27 and 0,4 BAR). if there is an unsupervised shut-off valve between the alarm check valve and the PS10A. MOUNTING: Device should be mounted in upright position(threaded connection down). Requires NEMA type 4 conduit hub for outdoor WET SYSTEM WITH EXCESS PRESSURE: installations. Connect PS10A into alarm port piping extending from alarm check valve. Retard provisions are not required. Insure that no unsupervised shut- TESTING:The operation ofthe pressure alarm switch should be tested off valves are present between the alarm check valve and the PS10A. upon completion of installation and periodically thereafter in accordance TESTING:Accomplished by opening the water by-pass test valve orthe with the applicable NFPA codes and standards and/or the authority inspector's end-of-line test valve.When using end-of-line test,allow having jurisdiction(manufacturer recommends quarterly or more fre- time for excess pressure to bleed off. quently). W DRYSYSTEM: ETSYSTEM: METHOD 1:When using PSi OA and control unitwith retard-connect Connect PS10A into alarm port piping thatextendsfrom the intermediate PS10A into alarm port piping on the input side of retard chamber and chamber ofthe alarm check valve. Install on the outlet side of the in-line electrically connect PS10A to control unit that provides a retard to checkvalveofthealarmportpiping. Insure that no unsupervised shut- compensate for surges.Insure that no unsupervised shut-off valves off valves are present between the alarm check valve and the P51 OA. are present between the alarm check valve and PS10A. TESTING:Accomplished by opening the water by-pass test valve. METHOD 2:When using the PS10A for local bell application or with a CAUTION: The above tests may also activate any other circuit closer control that does not provide a retard feature-the PS10A must be or water motor gongs that are present on the system. Potter Electric Signal Company•2081 Craig Road,St.Louis,MO,63146-4161 •Phone:800-325-3936/Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MKT.#8810001-REV V PAGE 1 OF 2 MFG.#5400923-8/02 MODEL PS10A P POTTER PRESSURE SWITCH ® The Symbol of Protection UIMtNSlUN5 SWITCH TERMINAL CONNECTIONS r—cc., NJI. 4,C CLAMPING PLATE TERMINAL NOTE - TO PREVENT LEAKAGE.NTPLY I Ii n: • ADJUSTMENT Q �° I 0(;01t46 2.TSO `� TEFLONATAPE I I I I (TJDrnD •/1:1 , e' SEALANT TO — �, / THREADS ONLY. - -_ _iii iii' MALE i�i��i��i_�� i��ii i ii WARNING; I I .. I -In) II. 0i,14 USCE NT MAY JOINT I I RESULT IN OBSTRUCTION OF THE APERTURE 0° DWG.#923-3 AND LOSS OF — = CAUTION: SIGNAL. I An uninsulated section of a single conductor should L2 ) I--soil not be looped around the terminal and serve as two DWG.#923-13770 - 75O separate connections. The wire must be severed, (1,1740(1,1740 (I24.I�m) thereby providing supervision of the connection in the event that the wire becomes dislodged from under the terminal. TYPICAL SPRINKLER APPLICATIONS WET SYSTEM WET SYSTEM DRY SYSTEM WITH EXCESS PRESSURE WITHOUT EXCESS PRESSURE PS IDA PSIDA ALARM PRESSURE WATER PSI OA MOTORWATER SWITCH WATER GONG MOTOR MOTOR ANA GONG GONG WET ENS RETARD ENS CHECK BVS SYSTEM- WET DRY ' VALVE SYSTEM H µµM SYSTEM A H 4 CHECK CHECK MARY VALVE CHECK RETARD I VALVE VALVE VALVE WA FR •1 •I OS k Y • BY-PASS WATER WATER VALVE •♦ VALVE OS k Y • RV-PASS os k Y• BY-PASS VALVE ♦ VALVE VALVE • VALVE DMC.1923-2 CAUTION: Closing of any shutoff valves between the alarm check valve and the PS10A will render the PS10A inoperative.To comply with NFPA-72 any such valve shall be electrically supervised with a supervisory switch such as Potter Model BVS. TYPICAL ELECTRICAL CONNECTIONS FOR LOW PRESSURE SIGNAL 'O.pRY IOP PRE-ACTON SYSTEMS PR"`R�NW 30 IS o-"' FOR WATER FLOW SIGNAL �= TO RING A LOCAL BELL FOR WATERFLOW 13II�1 PRESSURE SWITCH ¢a 110 cm E o N e ca� TERMINATION U. m ■■ ■■ ■■ ■■10 N ■■ POSITIVE DC TO FIRE ALARM PANEL SYSTEM OR HOT AC 0 NCREASI NEGATIVE DC PRESSURE OR NEUTRAL AC TO FIRE ALARM PANEL DWG.#5924-3 •t TYPICAL ORDERING INFORMA1 ION WATERPLOW Model Description Stock RiSrALUT ON 0 No. COIL N.O. N.C. PS10-1A Pressure switch with one set SPDT contacts 1340101 svnrcN MARKINGS PS10-2A Pressure switch with two sets SPDT contacts 1340102 LDW��URE �' Hex Key 5250062RNSON Cover Tamper Switch Kit 0090134 DEC SYST BVS 1/2" Ball Valve with tamper switch 1010150 PRESSURE O COM. N.D. N.C. SWITCH MARKINGS APPLICATION WARNING! CONTACT POSITION Due to the possibility of unintended discharges caused by pressure surges, trapped air, or short retard times, SHOWNWITH DEVICE IN ED waterflow switches that are monitoring wet pipe sprinkler systems should not be used as the sole initiating CONDITION device to discharge AFFF, deluge, or chemical suppression systems. DWG./982-4 ENGINEER/ARCHITECT SPECI FICATIONS Pressure type waterflow switches shall be a Model PS10A as manufactured by Potter Electric Signal Co. of St. Louis, Mo. and shall be installed on the sprinkler systems as shown on the drawings and/or specified herein. Switches shall be provided with a 1/2"NPT male pressure connection to be connected into the alarm check valve of a "wet"sprinkler system or into the intermediate chamber of a "dry"pipe system and shall be actuated by any flow of water to or in excess of the discharge from one sprinkler head. Switches shall have a maximum service pressure rating of 250 PSI (17,2 BAR) and shall be factory adjusted to operate on pressure increase at 6±1 PSI(0,4±0,06 BAR).There shall be one(1)or two(2)SPDT contacts rated at 15.0 Amps at 125/250VAC and 2.5 Amps at 30VDC. The switch housing shall be weather proof and oil resistant. The cover shall incorporate tamper resistant screws. The unit shall be UL and CSFM Listed,FM and LPC Approved,and NYMEA Accepted. PRINTED IN USA MKT.#8810001-REV V PAGE 2 OF 2 MFG.#5400923-8/02 MODEL PS40A P POTTER HIGH/LOW ® The Symbol of Protection PRESSURE SWITCHES MODEL PS40A PRESSURE SWITCH FOR MONITORING HIGH UL and CSFM Listed,FM and LPC Approved, AND/OR LOW PRESSURE VARIATIONS NYMEA Accepted,CE Marked Dimensions: 4 3/4" (12,1 cm)W x 2 1/4" (5,7cm)D x 4 3/8" (11,1cm)H Enclosure: Cover-Die-cast with textured red powdercoat finish. Base- Plated Steel Pressure Connection: 1/2"NPT Male Factory Adjustment: PS40-1 A: Operates on decrease at 30 PSI (2,1 BAR) PS40-2A: Operates on increase at 50 PSI(3,5 BAR),and on decrease at 30 PSI (2,1 BAR) 1 _S, � �Syouis,M,"f,`°"`"°" Pressure Range: 10- 175 PSI(0,7- 12,1 BAR) Model S40—b. a P340-1A Maximum Differential: Approx.2lbs.at 20 PSI(0,14@1,4 BAR) 5 lbs. at 175 PSI (0,35@12,1 BAR) API Maximum System Pressure: 250 PSI (17,2 BAR) Switch Contacts: SPDT(Form C) 15.0 Amps at 125/250VAC, 2.5 Amps at 30VDC One set in PS40-1A, Two sets in PS40-2A Environmental Specifications: Indoor or outdoor use • NEMA 4/IP55 Rated Enclosure - when used with proper conduit fittings Temperature range: -40°F to 140°F (-40°C to 60°C) (Not for use in hazardous locations) Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 Tamper: Cover incorporates tamper resistant fasteners that PS40-1A Single Switch-Stock No. 1340401 require a special key for removal. One key is supplied with each PS40-2A Double Switch-Stock No. 1340402 device. For optional cover tamper switch kit, order Stock No. 0090134. The Potter PS40A Series are pressure actuated switches de- of any shutoff or check valve. signed primarily to detect a 10 PSI (.7 BAR) increase and/or decrease from normal system pressure in automatic fire sprin- Provision for testing the unit can be accomplished with the kler systems. installation of a Potter Bleeder Valve(Model BVL)in the line to the PS40A. Typical applications are air pressure supervision in dry pipe systems and pressure supervision of pressure tanks, air supply Testing: The operation of the pressure supervisory switch or water supply. should be tested upon completion of installation and periodically thereafter in accordance with the applicable NFPA codes and INSTALLATION AND TEST PROCEDURES standards and/or the authority having jurisdiction(manufacturer recommends quarterly or more frequently). Mounting: Device should be mounted in upright position(thread- ed connection down). CAUTION: Testing the PS40A may activate other system con- nected devices. Requires NEMA type 4 conduit hub for outdoor installations. Dry System: Connect PS40A in air supply line on the system side Potter Electric Signal Company•2081 Craig Road,St.Louis,MO,63146-4161•Phone:800-325-3936/Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MKT.#8810002-REV T PAGE 1 OF 2 MFG.#5400924-8/02 MODEL PS40A PPOTTER HIGH/LOW ® The Symbol of Protection PRESSURE SWITCHES DIMENSIONS NOTE: 1 1 TO PREVENT LEAKAGE,APPLY TEFLON TAPE SEALANT Md ,C TO MALE THREADS ONLY. WARNING: I t I O '°' O I 2758 USE OF PIPE JOINT CEMENT MAY RESULT IN OBSTRUC- KNO,saENT I "OeAJ MiM)05 TION OF APERTURE AND LOSS OF SIGNAL. 1 I 4.375 I I � I (I1.1an) FIELD ADJUSTMENTS:The operating point of the switch(or L— _ switches on the PS40-2A) can be adjusted to any point between 10 and 175 PSI(0,7 and 12,1 BAR) by turning the adjustment knob(s) clockwise to raise the actuation point, and counter-clockwise to lower the actuation point. In the I.—case of the PS40-2A, the two switches operate completely �u. ) ca<°A,) independently of one another, and each switch may be axso „x) DWG. /924-30 adjusted to actuate at an `67m' "71e"' y point the system requires. Final adjustment should be made with a pressure gauge. Typical Sprinkler Application-Dry System Pressure Switch Terminations PRESSURE N.C. N.C. vsaw INCREASE COM. COM. N.O. • N.O. AR UNE r (13 PRESSURE • -OTT• BLEEDER nsla DECREASE • • VALVE v TEST W b[CA • VALVE PRESSURE • WAVE BVL 51YIfCH AM WATER COM. N.O. N.C. COM. N.O. N.C. DWG. 0926-3 —0 MOTOR GONG DRY ZVE8 895 Typical Electrical Connections Low AirOnly Low and High Air on the Same Zone OK#914-1 WATERS PS-40-AI PS-40-A2 osar� wLVE TT�ST LOW AIR SWITCH HIGH AIR SWITCH 13313 111011 LOW AIR SWITCH 111232 . EMCIIIBE 11Eir [�9 C� 0••rlin V�• •• — .. = .. ■. ■■ 1a TO FIRE ALARM PANEL TO FIRE ALARMPANEL I DWG. #5924-1 NOTE: High switch changes with pressure increase. Low switch changes with pressure decrease. Ordering Information Switch Terminal Connections Clamping Plate Terminal Model Description Stk.No. CAUTION: PS40-1A Pressure switch with one set SPDT contacts 1340401 It/6 An uninsulated section of a single PS40-2A Pressure switch with two sets SPDT contacts 1340402 ��r Ir conductor should not be looped BVL Bleeder Valve 1000018 �' around the terminal and serve as two Hex Key 5250062 separate connections. The wire must Cover Tamper Switch 0090134 .,c✓ be severed, thereby providing super- BVS 1/2" Ball Valve with tamper switch 1010150 bra' 923-3 vision of the connection in the event that the wire becomes dislodged from under the terminal. Engineer/Architect Specifications Air pressure supervisory switch shall be a Model PS40A as manufactured by Potter Electric Signal Co. of St. Louis, Mo. and shall be installed on the sprinkler systems as shown on the drawings and/or as specified herein. Switches shall be provided with a 1/2"NPT male pressure connection to be connected into the air supply line on the system side of any shut-off valve. A Model BVL bleeder valve as supplied by Potter Electric Signal Co.of St. Louis,Mo.or equivalent shall be connected in line with the PS40A to provide a means of testing the operation of the supervisory switch. (See DWG.#924-1) The switch unit shall contain SPDT(Form C)switch(es). One switch shall operate at a pressure decrease of 10 PSI (0,7 BAR)from normal. If two switches are provided, the second switch shall operate at a pressure increase of 10 PSI (0,7 BAR)from normal. Switch contacts shall be rated at 15.0 Amps at 125/250VAC and 2.5 Amps at 30VDC.The units shall have a maximum pressure rating of 250 PSI(17,2 BAR)and shall be adjustable from 10 to 175 PSI(0,7 to 12,1 BAR). The switch housing shall be weatherproof and oil resistant. The cover shall incorporate tamper resistant screws. The unit shall be UL and CSFM Listed,FM and LPC Approved,and NYMEA Accepted. PRINTED IN USA MKT.#8810002-REV T PAGE 2 OF 2 MFG.#5400924-8/02 VSR-F PPO VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD UL,U LC and CSFM Listed,FM an d LPCBApproved,NYMEA Accepted,CE Marked Service Pressure: Up to 450 PSI(31 BAR) Minimum Flow Rate forAlarm:10 GPM(38 LPM) Maximum Surge: 18 FPS(5,5 m/s) Contact Ratings: Two sets of SPDT(Form C) 15.0 Amps at 125/250VAC 2.0 Amps at 30VDC Resistive Conduit Entrances: Two knockouts provided for 1/2"conduit Environmental Specifications: • Suitable for indoor or outdoor use with factory installed gasket and die-cast housing. • NEMA 4/IP54 Rated Enclosure-use with appropriate •� conduit fitting. • Temperature Range: 40°F/120°F, 4,5°C/49°C • Non-corrosive sleeve factory installed in saddle. Caution:This device is not intended for applications in explosive environments. dfr Sizes Available: Steel Pipe schedules 10 thru 40,sizes 2"thru 8" BS 1387 pipe 50mm thru 200mm Note: For copper or plastic pipe use Model VSR-CF. Service Use: Automatic Sprinkler NFPA-13 U.S. Pat. No. 3921989 One or two family dwelling NFPA-13D Canadian Pat. No. 1009680 Residential occupancy up to four stories NFPA-13R Other Patents Pending National Fire Alarm Code NFPA-72 Potter Electric, Rd., 1990 Optional: Cover Tamper Switch Kit,Stock No.0090018 GENERAL INFORMATION INSTALLATION: See Fig.2 The Model VSR-F is a vane type waterflow switch for use on These devices may be mounted on horizontal or vertical pipe. wet sprinkler systems. It is UL Listed and FM Approved for On horizontal pipe they should be installed on the top side of the use on steel pipe; schedules 10 through 40, sizes 2" thru 8" pipe where they will be accessible. The units should not be in- (50mm thru 200mm). stalled within 6"(15cm)of a fitting which changes the direction of LPC approved sizes are 2" thru 8" (50mm thru 200mm). the waterflow or within 24" (60 cm) of a valve or drain. The unit may also be used as a sectional waterflow detector Drain the system and drill a hole in the pipe using a circular saw on large systems. in a slow speed drill.The 2"(50mm) and 2 1/2" (65mm)devices require a hole with a diameter of 1 1/4" + 1/8" - 1/16" (33mm The unit contains two single pole, double throw, snap action ±2mm).All other sizes require a hole with a diameter of 2"±1/8" switches and an adjustable, instantly recycling pneumatic re- (50mm ±2mm). tard. The switches are actuated when a flow of 10 gallons per minute (38 LPM) or more occurs downstream of the device. Clean the inside pipe of all growth or other material for a dis- The flow condition must exist for a period of time necessary to tance equal to the pipe diameter on either side of the hole. overcome the selected retard period. Roll the vane so that it may be inserted into the hole;do not bend ENCLOSURE: The unit is enclosed in a general purpose, die- or crease it. Insert the vane so that the arrow on the saddle cast housing. The cover is held in place with two tamper resis- points in the direction of the waterflow. Install the saddle strap tant screws which require a special key for removal. A field in- and tighten nuts alternately to an eventual 50 ft-lbs. (68 n-m) of stallable cover tamper switch is available as an option which torque(see Fig. 2).The vane must not rub the inside of the pipe may be used to indicate unauthorized removal of the cover. See or bind in any way. bulletin no. 5400775 for installation instructions of this switch. Specifications subject to change without notice. Potter Electric Signal Company•2081 Craig Road,St.Louis,MO,63146-4161 •Phone:800-325-3936/Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MKT.#8800001-REV W PAGE 1 OF 2 MFG.#5400761-7/02 VSR-F P POTTER VANE TYPE WATERFLOW ® The Symbol of Protection ALARM SWITCH WITH RETARD FIG. 1 FIG.2 SWITCH TERMINAL CONNECTIONS OPTIONAL TAMPER SWITCH DO NOT LEAVE COVER OFF FOR EXTENDED PERIOD OF TIME CLAMPING PLATE TERMINAL RETARD ADJUSTMENT: 'fl TO CHANGE TIME TURN KNOB (EITHER DIRECTION) `1�[''/ �� � TIGHTEN NUTS FOR DESIRED TIME DELAY. USE THE MINIMUM '',44:211\\ 11� �l\`! ALTERNATELY TO AN AMOUNT OF RETARD NECESSARY TO PREVENT �'�y : �' EVENTUAL 50 FT.-LBS (68 n-m) INS FALSE ALARMS, A "B" SETTING IS USUALLY ��I`�� OF TORQUE (,_!_r.), �� I ADEQUATE FOR THIS. FACTORY IS SET TO "B". < ,'-� . 4: ✓� TO INSTALL, DRILL HOLE AS INDICATED: \ 1 PIPE SIZE HOLE SIZE TO 00 it46 DWG./923-3 2" to 2 1/2" 1 1/4" +1/8" -1/16" ,��\ MOUNT ON PIPE SO (50mm to 65mm) (33mm ±2mm) A1mi ARROW ON SADDLE CAUTION: Y POINTS IN DIRECTION 3" to 8" 2" ±1/8" OF WATERFLOW An uninsulated section of a (80mm to 200mm) 50mm ±2mm) single conductor should not 0 ROLL PADDLE IN Cover Tamper OPPOSITE DIRECTION be looped around the termi- r7..) OF WATERFLOW nal and serve as two sepa- rate connections. The wire • must be severed, thereby ©©1 DIRECTION ROWOF providing supervision of the C NO O \\ i APPROX. RETARD SETTINGS (IN SECS.) connection in the event that (WMT) (RED) (BLN) OM./-W41-2 0 A BC DE the wire becomes dislodged DWG. #761-30 0 10-25 20-40 35-55 50-70 60-90 from under the terminal. FIG. 3 TYPICAL ELECTRICAL CONNECTIONS NOTES: FIG.4 1. The Model VSR-F has two To remove knockouts: Place switches, one can be used to screwdriver at edge of knock- 2 SETS OF operate a central station, pro- outs, not in the center. NORSILLY OPEN CONTACTS NATER LON ZONE EOLR IRON CLOSE ON ALAR" ON ONE PANEL nRE R.REL prietary or remote signaling MM=IN `o_ unit,while the other contact is 0 D D C:J O \",� 1 I1Z 1,�`I 1t�,11 I,�`1 used to operate a local audible 1 1 0 0 0 CI 1:31or visual annunciator. IMF l I,l IC��1I'`IIC I 2. A condition of LPC Approval of EN mi ■■ ■■ A THE NC ANO NO,,, iGS POSTNE DC this product is that the electri- N!ENE {ARNT,a,°A NOT AC cal entry must be sealed to --I, NEGATIVE DC `HE woNM REVERSEDS ARE ca m&ac ,,,4 E„1-, exclude moisture. 1i Q Y-! TFCRA&COMM 3. For supervised circuits see e "Switch Terminal Connec- tions” drawing and caution DWG. 1761-4 note(Fig. 1). APPLICATION WARNING! Due to the possibility of unintended discharges caused by pressure surges, trapped air, or short retard times,waterflow switches that are monitoring wet pipe sprinkler systems should not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. TESTING The frequency of inspection and testing for the model VSR-F and its associated protective monitoring system should be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). If provided,the inspector's test valve,that is usually located at the end of the most remote branch line, should always be used for test purposes. If there are no provisions for testing the operation of the flow detection device on the system, application of the VSR-F is not recommended or advisable. A minimum flow of 10 gpm(38 Lpm) is required to activate this device. IMPORTANT NOTICE: Please advise the person responsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions. PRINTED IN USA MKT.#8800001-REV W PAGE 2 OF 2 MFG.#5400761-7/02 BELLS PPOTTER PBA-AC & PBD-DC ® The Symbol of Protection UL Listed,FM Approved Sizes Available:6"(150mm),8"(200mm)and 10"(250mm) Voltages Available: 24VAC . 120VAC 12VDC(10.2 to 15.6)Polarized 24VDC(20.4 to 31.2)Polarized : Service Use: Fire Alarm I"' General Sinirk , _ � Signaling -o- Burglar Alarm Environment: Indoor or outdoor use(See Note 1) -40°to 150°F(-40°to 66°C) (Outdoor use requires weatherproof backbox.) Termination: 4 No. 18 AWG stranded wires 6" BELL SHOWN Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox These vibrating type bells are designed for use as fire, burglar or general signaling devices. They have low power con- sumption and high decibel ratings. The unit mounts on a standard 4" (101 mm) square electrical box for indoor use or on a model BBK-1 weatherproof backbox for outdoor applications. Weatherproof backbox model BBK-1, Stock No. 1500001. ALL DC BELLS ARE POLARIZED AND HAVE BUILT-IN TRANSIENT PROTECTION: SIZE CURRENT TYPICAL dB MINIMUM dB INCHES VOLTAGE MODEL NO. STOCK NO. ( ) AT 10 FT. AT 10 FT. (mm) (3m)(2) (3m)(1) 6(150) 12VDC PBD126 1706012 12A 85 76 8(200) 12VDC PBD128 1708012 .12A 90 76 10(250) 12VDC PBD1210 1710012 .12A 92 76 6(150) 24VDC PBD246 1706024 .06A 87 76 8(200) 24VDC PBD248 1708024 .06A 91 79 10(250) 24VDC PBD2410 1710024 06A 94 79 6(150) 24VAC PBA246 1806024 .17A 91 76 8(200) 24VAC PBA248 1808024 .17A 94 76 10(250) 24VAC PBA2410 1810024 .17A 94 76 6(150) 120VAC PBA1206 1806120 .05A 92 82 8(200) 120VAC PBA1208 1808120 05A 99 82 10(250) 120VAC PBA12010 1810120 05A 99 85 Notes: 1. Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is-30°to 150°F(-34°to 66°C). 2. Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. Potter Electric Signal Company•2081 Craig Road,St.Louis,MO,63146-4161 •Phone:800-325-3936/Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MKT.#8850001-REV Q PAGE 1 OF 2 MFG.#5400776-12/01 P POTTER BELLS PBA-AC & PBD-DC ® The Symbol of Protection DIMENSIONS INCHES(mm) FIG. 1 BELLS FIG. 2 WEATHERPROOF BACKBOX BOX HAS ONE THREADED 1/2"CONDUIT ENTRANCE [ :[1 1 10" --TH— (250) 1"-1- 5 3/4" _ 3 3/8' 5" 8" i I (146)LI— fa O (86) (127) 0D(200) 6" I (150) 0 I I - .6)--) D. —�1 6/8'� (86) 3 3/8" (41) 4 1/4" 2 11/16" -- owc. 1776-11 (1 ) (68) DWG. #776-2 FIG. 3 WIRING (REAR VIEW) D.C. BELLS (OBSERVE POLARITY) A.C. BELLS RED (IN) ,daiRED (OUT) WHITE (IN) Adimhh. WHITE (OUT) FROM CONTROL PANEL ("r0 TO NEXT BELL FROM CONTROL PANEL tilleilOR I' OR ENS-OF-LINE �'' PRECEDING BELL RESISTOR PRECEDING BELL BLACK (IN) _ISOM& BLACK (OUT) BLACK (IN) -�' BLACK (OUT) CAUTION- CAUTION, WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. WHEN ELECTRICAL SUPERVISION IS REOUIRED USE IN AND OUT LEADS AS SHOWN. NOTES: NOTES: 1, OBSERVE POLARITY TO RING D.C. BELLS. 1. WHEN USING A.C. BELLS, TERMINATE EACH EXTRA WIRE SEPARATELY 2, RED WIRES POSITIVE (+) AFTER LAST BELL 3. BLACK WIRES NEGATIVE (-) 2, END-OF-UNE RESISTOR IS NOT REQUIRED ON A,C. BELLS. DWG. #776-3 INSTALLATION 1. The bell should be mounted a minimum of 8 ft. (2,4m)from the floor or as close to the ceiling as possible. 2. Remove the gong. 3. Connect wiring(see Fig.3). 4. Mount bell mechanism to backbox(bell mechanism must be mounted with the striker pointing down). 5. Reinstall the gong(be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). 6. Test all bells for proper operation and observe that they can be heard where required(bells must be heard in all areas as designated by the authority having jurisdiction). PRINTED IN USA MKT.#8850001-REV Q PAGE 2 OF 2 MFG.#5400776-12/01 DELT 14795ORTLANDS.W. 72"d Avenue P , OR PHONE 503-620-4020 FIREINC. FAX 503-620-1058 ■ CCB# 64174 7 BACKF LOW DEVICE FIRE PROTECTION CONTRACTORS ES-A-C300/C300N Colt Series C300, C300N AMES FIRE&WATERWORKS Double Check Detector Assemblies Sizes: 21/2" — 10" (65 —250mm) �_. C300BFG C3000SY — i 3 iA 1. • .: 11 1011,11011111115 /1 N r Features The Colt C300, C300N Double Check Detector Assemblies are used to • Extremely Compact Design prevent backflow of pollutants, that are objectionable but not toxic, from • 70% Lighter than Traditional entering the potable water supply system.The Colt C300, C300N may Designs be installed under continuous pressure service and may be subjected • 304 (Schedule 40) Stainless Steel to backpressure. The Colt C300, C300N is used primarily on fire line Housing &Sleeve sprinkler systems when it is necessary to monitor unauthorized use of water. For use in non-health hazard applications. • Groove Fittings Allow Integral Pipeline Adjustment • Patented Tri-Link Check Provides Specifications Lowest Pressure Loss The Colt C300, C300N Double Check Detector Assemblies shall consist • Unmatched Ease of Serviceability of two independent Tri-Link Check modules within a single housing, • Available with Grooved Butterfly sleeve access port, four test cocks and two drip tight shutoff valves. Valve Shutoffs Tri-Link Checks shall be removable and serviceable, without the use of May be Used for Horizontal, special tools. The housing shall be constructed of 304 (Schedule 40) • Vertical or N Pattern Installations stainless steel pipe with groove end connections. Tri-Link Checks shall Replaceable Check Disc Rubber have reversible elastomer discs and in operation shall produce drip tight • closure against the reverse flow of liquid caused by backpressure or backsiphonage. The bypass assembly shall consist of a meter, which registers in either gallon or cubic measurement, a double check valve assembly and required test cocks. Assembly shall be a Colt C300, C300N as manufactured by the Ames Company. Job Name Contractor Job Location Approval Engineer Contractor's P.O.No. Approval Representative Ames product specifications in U.S.customary units and metric are approximate and are provided for reference only.For precise measurements,please contact Ames Technical Service.Ames reserves the right to change or modify product design,construction,specifications,or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames products previously or subsequently sold. www.amesfirewater.com Configurations Available Models • Horizontal Suffix: • Vertical up OSY- UUFM outside stem and yoke resilient • "N" pattern horizontal seated gate valves BFG - UUFM grooved gear operated butterfly valves Materials with tamper switch • Housing &Sleeve: 304 (Schedule 40) Stainless Steel "OSY FxG - Flanged inlet gate connection and grooved • • Elastomers: EPDM, Silicone and Buna 'N' outlet gate connection • Tri-Link Checks: Noryl®, Stainless Steel *OSY GxF - Grooved inlet gate connection and flanged • Check Discs: Reversible Silicone or EPDM outlet gate connection • Test Cocks: Bronze Body Nickel Plated "OSY GxG -Grooved inlet gate connection and grooved outlet gate connection • Pins& Fasteners: 300 Series Stainless Steel Available with grooved NRS gate valves -consult factory` • Springs: Stainless Steel Post indicator plate and operating nut available-consult factory* "Consult factory for dimensions Dimensions — Weights Pressure — Temperature Temperature Range: 33°F- 140°F (5°C-60°C) Maximum Working Pressure: 175psi (12.06 bar) fI� w �I Coen " Ot11111111: 111k� 111, �� y I I illiggiall_h- oi< * H A Ewa D I G • P C300, C300N SIZE(DN) DIMENSIONS WEIGHT ,A C(OSY) D G H I J P C300 C300N in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kqs. lbs. kqs. 21/2 65 31 787 163/6 416 311 89 291/26 738 22 559 1511 393 813/6 223 133A6 335 139 63 147 67 3 80 3111/16 805 181/2 479 311/26 94 3014 768 22% 578 1712 435 93/6 233 1412 368 159 72 172 78 4 100 3311/16 856 223/4 578 4 102 33 838 24 610 181/2 470 915/6 252 153/6 386 175 79 198 90 6 150 4312 1105 30'/2 765 512 140 44% 1137 33% 857 233A6 589 1316 332 19 483 309 140 350 159 8 200 50 1270 37% 959 6116 170 54% 1375 40% 1032 271/6 697 15116 399 213/6 538 494 224 569 258 10 250 571/2 1460 453/4 1162 83/16 208 66 1676 50 1270 321/2 826 175/16 440 24 610 795 361 965 438 w w -- EL� �m .. 11 C UUrk J fi�i°� ■ NilCII)•.-..irmrd Amp_:-.,-----mii E117 . I 1., =r ire l �.� A L l H I P I C300BFG, C300NBFG G SIZE(ON) DIMENSIONS WEIGHT A C D G H I J P C300BFG C300NBFG in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. lbs. kgs. 211 65 28 711 8 203 312 89 291/2 759 22 559 1415/6 379 813/16 223 13 330 70 32 78 35 3 80 281/2 724 85/6 211 3"/16 94 3011/26 779 22% 578 151/6 392 93/6 233 1312 343 68 31 81 37 4 100 293/6 741 815/6 227 311/6 94 3115A6 811 24 610 161 412 915/6 252 14 356 75 34 98 44 6 150 3611 927 10 254 5 127 433/6 1097 33% 857 19116 500 13116 332 141/2 368 131 59 171 78 8 200 43 1092 1214 311 611 165 51116 1297 40% 1032 235/6 592 151116 399 183/16 462 275 125 351 159 Noryl®is a registered trademark of General Electric Company. Approvals ��psS/f,4, z, c ® US 4z› o�® .m Approved 1048 864.4 For additional approval information please contact the factory or visit our website at www.amesfirewater.com Capacity UUFM Certified Flow Characteristics Flow characteristics collected using butterfly shutoff valves. See literatue S-Colt-200/300 for gate valve flow characteristics * = Rated Flow ** = UL Tested Horizontal Vertical N - Pattern kPa psi 2' " (65mm) 6" (150mm) Pa p4 * ** kPa psi * ** 9683 12 N 83 12 N69 10 H H 55 69 18 ''0 � H 55 8 � ,� 41 6 28 4m 28 4 14 2 14 2 0 0 0 0 0 50 100 150 200 250 300 350 gpm 0 300 600 900 1200 1500 gpm 0 190 380 570 760 950 1140 1330 Ipm 0 1140 2280 3420 4560 5700 Ipm 15 fps 15 fps 4.6 mps 4.6 mps kPa psi 3" (80mm)* ** kPa psi 8" (200mm) * ** 83 12 83 12 N 69 10 - H 69 10 55 8 -- — �..-- N 55 8 41 6 �� v 41 6 tee •- � � � �— ! . 28 4 ..,. 28 4 X - F 14 2 14 2 — 0 0 0 0 0 100 200 300 400 500 gpm 0 500 1000 1500 2000 2500 gpm 0 380 760 1140 1520 1900 Ipm 0 1900 3800 5700 7600 9500 Ipm 15 fps 15 fps 4.6 mps 4.6 mps 4" (100mm)* kPa psi 10" (250mmm kPa psi ** ** 165 24 83 12 138 20 � _ N 69 10 N 110 16 -� H 55 8 .."" H 83 12 ..__.._;_______,„....•"" ' 41 6 s _'` 55 8 �--.% 28 4 � 0 0 0 0 0 100 200 300 400 500 600 700 800 gpm - 0 380 760 1140 1520 1900 2280 2660 3040 Ipm 0 500 1000 1500 2000 2500 3000 3500 gpm 15 fps 0 1900 3800 5700 7600 9500 11400 13300 Ipm 4.6 mps fps mps IMPORTANT:INQUIRE WITH GOVERNING AUTHORITIES FOR LOCAL INSTALLATION REQUIREMENTS For additional information, visit our web site at: www.amesfirewater.com (ILO) AM E S ®• 9001-2000 FIRE&WATERWORKS• www.amesfirewater.com 'MfMBEP • RTIFIED A Watts Water Technologies Company USA: Backflow-1427 N.Market Blvd•Suite#9•Sacramento,CA 95834•T:916-928-0123•F:916-928-9333 Control Valves-18550 Hansen Road•Houston,TX 77075•T:713-943-0688•F:713-944-9445 Canada: 5435 North Service Rd.•Burlington,ONT.L7L 5H7•T:905-332-4090•F:905-332-7068 ES-A-C300/C300N 1006 ©2010 Ames Fire&Waterworks 14795 D EPORT S.W. 72nd 97224e PORTLAND, ORR Avenue PHONE 503-620-4020 FIRE, INC. FAX 503-620-1058 CCB# 64174 MISCELLANEOUS FIRE PROTECTION CONTRACTORS �r l r idr } t r ors k t Base Plate Mounted • Directional air shroud for reduced pump temperatures Standard Features •Totally enclosed heavy-duty belt guard • Heavy-duty single stage cast iron compressor pump • Powder coated, extra heavy steel base plate Made in Somerset, PA USA • Large canister intake filter with replaceable filter elements • Splash lubricated ■ Magnetic starter is included on all 5HP and larger units • Belt driven with a large flywheel for extra cooling and easier start-up • Industrial/Commercial grade UL Listed electric motor • Each unit is filled with,Jenny Ultimate Blue Compressor Pump Oil •Thermal overload motor protection Base Mounted System Size Optional Maximum Gallons Auto F12S-30S in system to be pumped to 40 PSI Pump CFM del'd @ Control N. in 30 Minutes Model Pump HP Power Supply RPM 40 PSI Group 220 F13S-BS 1/3 670 2.9 $ •• f' 290 F12S-BS F 1/2 950 3.8 ACGF F-: ,. 350 F34S-BS 115 Volt 1200 4.4 K34S-BS K 3/4 (through 2 HP) 425 or 230 Volt 520 5.3 ACGK jeY 480 F1S-BS F1 1 Phase 1430 6.0 ACGF 600 K1 S-BS 790 7.4 885 K15S-BS K 1-1/2 1140 10.9 ` ACGK -. ' 985 K2S-BS 208, 230, 1280 12.4 1215 G2S-BS 2 460 or 630 15.1 l 575 Volt x 1775 G3S-BS G 3 3 Phase 950 21.8 ACGD 1950 GC5S-BS.li5 1030 24.2 ACGJ 2115 J5S-BS J 830 26.0 Tank Mounted/30 Gallon 220 F13S-30UMS 1/3 670 2.9 pr 290 F12S-30UMS F 1/2 950 3.8 'f 350 F34S-30UMS 3/4 115 Volt 1200 4.4 425 K34S-30UMS K (through 2 HP) 520 5.3 - k 480 F1 S-30UMS F 230 se 1430 6.0 GC5S-30S 1 1 'Phas -N 600 K1S-30UMS 790 7.4 '4%.';‘,Z 885 K15S-30UMS K 1-1/2 1140 10.9 985 K2S-30UMS 208, 230, 1280 12.4 �a 2 460 or 1215 G2S-30UMS G 575 Volt 630 15.1 775 G3S-30UMS 3 3 Phase 950 21.8 1950 GC5S-30UMS GC 1030 24.2 �.,o R. -. .. 2115 J5S-30UMS J 5 830 26.0 .101flY Tank Mounted Additional Standard Features Options -,,. •Tanks are powder coated and ASME certified ASME National Board tank • Protectively mounted fittings Magnetic starter N K15S-30S ■Manual tank drain(s) 17 gallon tank•Vertical tank • Large canister intake filter with replaceable filter elements Low oil level switch •Oil sight glass • Special unloading valves to assist in motor starting ■Tank gauge Automatic tank drain •Air line filter • Pressure relief safety valve Aftercooler■ Dryer ■Auto Start/Stop control with pressure unloader set at 25-40 PSI Control Group IR COMPRESSORS ';:s4%-,1s,1st. f _, 7 Product Information N1`7.1 FS-ONE ,: High Performance Intumescent Firestop Sealant Product description • Intumescent(expands when exposed to fire)firestop sealant that - �, helps protect combustible and non-combustible penetrations for ::fes up to 4 hours fire rating A. . . Product features ,- . , :, , • Smoke,gas and water resistant after material has cured .- ■ Contains no halogen,solvents or asbestos '..=:1,--;:.• .. ■ High fire rating properties -` u • Water based,easy to clean IN Protects most typical firestop penetration applications • Paintable Technical Data* FS-ONE • Single component systems available Chemical basis Water-based intumescent acrylic INMeets LEEDTm requirements for indoor environmental quality credit dispersion 4.1 Low Emitting Materials,Sealants and Adhesives and 4.2 Paints Color Red and Coatings Application temperature 40°F to 104°F(5°C to 40°C) Skin forming time Approx.20-30 min. Areas of application Curing time Approx.2 mm/3 days ■ Steel,copper and EMT pipes Movement capability Approx.5% • Insulated steel and copper pipes Expansion rate(unrestricted) Up to 3-5 times original volume • Cable bundles Temperature resistance(cured) -40°F to 212°F(-40°C to 100°C) • Closed or vented plastic pipes Surface burning characteristics Flame Spread:0 • HVAC penetrations (ASTM E 84-96) Smoke Development:5 Sound transmission classification 56(Relates to specific construction) For use with (ASTM E 90-99) • Concrete,masonry,drywall and wood floor assemblies Approvals ■ Wall and floor assemblies rated up to 4 hours •California State Fire Marshal- No.4485-1200:108 •City of New York-MEA 326-96-M Vol.IV Examples Tested in accordance with • Sealing around combustible pipe penetrations in fire rated •UL 1479 •ASTM E 814 •ASTM E 84 construction "At 73°F(23°C)and 50%relative humidity ■ Sealing around non-combustible penetrations in fire rated construction o psOo FILL,VOID OR CAVITY MATERIAL {` . FOR USE IN THROUGH-PENETRATION FIRESTOP SYSTEMS ® UC USSEE UL FIRE RESISTANCE DIRECTORY 66Y7 APPROVED SYSTEM COMPATIBLE Installation instructions for FS-ONE Notice 4. Smoothing of firestop sealant:To complete the • On materials where oil,plasticizers or solvents may • Before handling,read Material Safety Data Sheet seal,tool immediately to give a smooth appearance. bleed i.e.impregnated wood,oil based seals,green and product label for safe usage and health Excess sealant,prior to curing,can be cleaned away or partially vulcanized rubber information. from adjacent surfaces and tools with water. • In any penetration other than those specifically • Instructions below are general guidelines—always 5. Leave completed seal undisturbed for 48 hours. described in this manual or the test reports refer to the applicable drawing in the UL Fire 6. For maintenance reasons,a penetration seal could Resistance Directory or Hilti Firestop Systems Guide be permanently marked with an identification plate. Storage for complete installation information In such a case,mark the identification plate and Store only in the original packaging in a location protected from moisture at temperatures between Opening fasten it in a visible position next to the seal. 40°F(5°C)and 86°F(30°C) 1. Clean the opening.Surfaces to which FS-ONE will Not for use • Observe expiration date on the packag be applied should be cleaned of loose debris,dirt, • High movement expansion joints oil,moisture,frost and wax.Structures supporting • Underwater penetrating items must be installed in compliance with local building and electrical standards. LULi .. Application of firestop sealant _. 2. Install the prescribed backfilling material type and W ,►depth to obtain the desired rating(if required).Leave C) ;' El .- N 04 °''. �_sufficient depth for applying FS-ONE. 3. Application of firestop sealant:Apply FS-ONE to the 1.Clean opening. 2.Pack mineral wool. 3.Apply FS-ONE. 4.Smooth 5.Leave completed 6.Fasten identification required depth in order to obtain the desired fire rating. r required) FS-ONE. sea undistu bed fo pa a(d aqui ed. 48 hours. Make sure FS-ONE contacts all surfaces to provide maximum adhesion.For application of FS-ONE use a F1E1E]standard caulking gun,foil pack gun,bulk loader and D .) ;bulk gun.With FS-ONE buckets,Graco type sealant pumps may be used.(Contact pump manufacturer for ` proper selection). 1.Clean opening. 2.Pack mineral wool. 3.Apply FS-ONE. 4.Smooth 5.Leave completed 6.Fasten identification (If required) FS-ONE. seal undisturbed for plate(if required). 48 hours. Hilti. Outperform. Outlast. Hilti,Inc.(U.S.)1-800-879-8000•www.us.hilti.com•en espanol 1-800-879-5000•Hilti Firestop Systems Guide Material S:ltety U. is Shoe; MSDS No.: 259 Revision No.: 010 Revision Date: 08/17/04 Page: 1 of 2 Product name: FS-ONE High Performance Intumescent Firestop Sealant Description: One-part acrylic-based sealant Supplier: Hilti. Inc. P.O.Box 21148,Tulsa, OK 74121 Emergency#(Chem-Trec.): 1 800 424 9300(USA, PR,Virgin Islands,Canada);001 703 527 3887(other countries) INGREDIENTS AND EXPOSURE LIMITS Ingredients: CAS Number: PEL: TLV: STEL: Polyacrylate dispersion Mixture NE NE NE Calcium carbonate 001317-65-3 5 mg/m'm 10 mg/m'(T) NE Zinc borate 138265-88-0 NE NE NE Ammonium polyphosphate 068333-79-9 NE NE NE Talc 014807-96-6 20 mppcf 2 mg/m3 NE Expandable graphite 012777-87.6 5 mg/m'(T) 2 mg/m'(T) NE Ethylene glycol 000107-21-1 NE C:100 mg/m'(A) NE Polybutene 009003-29-6 NE NE NE Iron oxide 001309-37-1 10 mg/m' 5 mg/m3 NE Glass filament 065997-17-3 NE 5 mg/m'-(T) NE Silicon dioxide 014808-60-7 0.05 mg/m'(T) 0.1 mg/m'(T) NE Water 007732-18-5 NE NE NE Abbreviations: PEL=OSHA Permissible Exposure Limit. TLV=ACGIH Threshold Limit Value. C=Ceiling. STEL=Short Term Exposure Limit. NE=None Established. NA=Not Applicable. (T) indicates"as total dust". (R)indicates"as respirable fraction". (A)indicates "as an aerosol". mppcf=million particles per cubic foot. PHYSICAL DATA Appearance: Red paste. Odor: Odorless. Vapor Density: (air=1) Not determined. Vapor Pressure: 23mbar©20C/68F Boiling Point: Not applicable. VOC Content 75.0 g/L. Evaporation Rate: Not applicable. Solubility in Water: Soluble. Specific Gravity: 1.5 pH: Not determined. FIRE AND EXPLOSION HAZARD DATA Flash Point: Non-flammable. Flammable Limits: Not applicable. Extinguishing Media: Not applicable. Use extinguishing media as appropriate for surrounding fire. Special Fire Fighting Procedures: None known. Use a self-contained breathing apparatus when fighting fires involving chemicals. Unusual Fire and Explosion Hazards: None known. Thermal decomposition products can be formed such as oxides of carbon, sulfur and phosphorous. REACTIVITY DATA Stability: Stable. Hazardous Polymerization: Will not occur. , Incompatibility: Strong acids, peroxides,and oxidizing agents. Decomposition Products: Thermal decomposition can yield CO and CO2. Conditions to Avoid: None known. HEALTH HAZARD DATA Known Hazards: None known. Signs and Symptoms of Exposure: Possibly irritating upon contact with the eyes or upon repeated contact with the skin. Medical Conditions Eye and skin conditions. Aggravated by Exposure: Routes of Exposure: Dermal. m`m Hilti Firestop Saving Lives through innovation Hilti. Outperform. Outlast, and education ,00 t,., .s. ; 1-800-879-8000•www.ts.hittl.com• sr::.. ni 1-800-879-5000•i11, r. 3.1.7,, i„• 1-800-363-4458 www.hllti.ca • MEt1,2ri,a1 Safety 1Jait.,Sheet MSDS No.: 259 Revision No.: 010 Revision Date: 08/17/04 Page: 2 of 2 Carcinogenicity: IARC classifies crystalline silica(quartz sand)as Group I based upon evidence among workers in industries where there has been long-term and chronic exposure(via inhalation)to silica dust;e.g. mining,quarry,stone crushing, refractory brick and pottery workers. This product does not pose a dust hazard;therefore,this classification is not relevant. Based upon the nature and intended use of this product, it does not pose an increased cancer risk to workers. EMERGENCY AND FIRST AID PROCEDURES Eyes: Immediately flush with plenty of water. Call a physician if symptoms occur. Skin: Immediately wipe off material and wash with soap and water. Material can adhere to the skin. If material has adhered to the skin,use an abrasive containing hand cleaner. If material does not come off, buff with a pumice stone. Inhalation: Move victim to fresh air if discomfort develops. Call a physician if symptoms persist. Ingestion: Seek medical attention. Do not induce vomiting unless directed by a physician. If a large quantity was ingested,give 1 to 2 glasses of water to dilute. Never give anything by mouth to an unconscious person. Other: Referral to a physician is recommended if there is any question about the seriousness of the injury/exposure. CONTROL MEASURES AND PERSONAL PROTECTIVE EQUIPMENT Ventilation: General(natural or mechanically induced fresh air movements). Eye Protection: Not required,however,safety glasses should be worn in most industrial settings. Skin Protection: Avoid skin contact. Cloth gloves are suitable for hand protection. Respiratory Protection: None normally required. Where ventilation is inadequate to control vapors, use a NIOSH- approved respirator with organic vapor cartridges. Never enter a confined space without an appropriate air-supplied respirator. PRECAUTIONS FOR SAFE HANDLING AND USE Handling and Storing Precautions: Store in a cool,dry area preferably between 40o and 77o F. Keep from freezing. Do not store in direct sunlight. Avoid contact with the eyes or skin. Practice good hygiene;i.e. always wash thoroughly after handling and before eating or smoking. For industrial use only. Keep out of reach of children. Follow label/use instructions. Spill Procedures: Immediately wipe away spilled material before it hardens. Place in a container for proper disposal in accordance with all applicable local,state,or federal requirements. REGULATORY INFORMATION Hazard Communication: This MSDS has been prepared in accordance with the federal OSHA Hazard Communication Standard 29 CFR 1910.1200. HMIS Codes: Health 1, Flammability 0, Reactivity 0, PPE 8 DOT Shipping Name: Not regulated. IATA/ICAO Shipping Name: Not regulated. TSCA Inventory Status: Chemical components listed on TSCA inventory.SARA Title Ill, Section 313:This product contains<3% ethylene glycol(CAS 107-21-1)and< 15%zinc borate(re:zinc compounds)which are subject to reporting under Section 313 of SARA Title III(40 CFR Part 372). EPA Waste Code(s): Not regulated by EPA as a hazardous waste. Waste Disposal Methods: Consult with regulatory agencies or your corporate personnel for disposal methods that comply with local,state,and federal safety,health and environmental regulations. CONTACTS Customer Service: 1 800 879 8000 Technical Service: 1 800 879 8000 Health/Safety: 1 800 879 6000 Jerry Metcalf(x6704) Emergency# (Chem-Trec): 1 800 424 9300(USA, PR,Virgin Islands,Canada); 001 703 527 3887(other countries) The information and recommendations contained herein are based upon data believed to be correct;however, no guarantee or warranty of any kind expressed or implied is made with respect to the information provided. p Hitti Firestop M Saving Lives through innovation Hilti. Outperform. Outlast. and education t ,,z-. m. 1-800-879-8000•www.us.hllti.com•; :.n:_ 1-800.879-5000•_ ,i, ;.:-r1E -.1-.1' 1-800-363-4458 www.hlltLca Certificate of Corn ' Nance Certificate Number 20100512-R13240 Page 1 of 1 Report Reference 2010 May 12 Issue Date 2010 May 12 Underwriters Laboratories Inc.ce Issued to: Hilti, Inc. 54 S 122ND East AVe Tulsa, OK 74146 USA This is to certify that Fill, Void or Cavity Materials representative samples of FS-ONE Have been investigated by Underwriters Laboratories Inc. (UL)or any authorized licensee of UL in accordance with the Standard(s)indicated on this Certificate. Standard(s)for Safety: ANSWL 1479, ANSI/UL 2079, CAN/ULC-S115-05 Third Edition,revised March 1, 2010 Additional Information: FS-ONE Sealant for use in Joint Systems and FS-ONE for use in Through-Penetration Firestop Systems as currently described in the UL Fire Resistance Directory. Only those products bearing the UL Classification Mark should be considered as being covered by UL's Classification and Follow-Up Service. vow The UL Classification Mark includes: UL in a circle symbol: with the word"CLASSIFIED"(as shown);a control number (may be alphanumeric) assigned by UL; a statement to indicate the extent of UL's evaluation of the product; and, the product category name(product identity)as indicated in the appropriate UL Directory. Look for the UL Classification Mark on the product lssti����Gl��I,�Z.�=�• Reviewed `, �' Chris . Mona Couloute nson Underwriters Laboratories Inc: Underwriters Laboratories Inc: Anyynformation and documentation ins ulving UL Mark services are provided on behalf of Underwriters laboratories"Inc.(UL)or any Authorized licensee of UL. Certificate of Com ' Bance Certificate Number 20060214-R13240E Page 1 of 1 Report Reference 2006 February 14 Issue Date 2006 February 14 Underwriters YL Laborat rl Inc.,o es Issued to: Hilti, Inc. 5400 S 122ND East Ave Tulsa, OK 74146 USA This is to cert fit that Fill, Void or Cavity Materials representative samples of FS-ONE Have been investigated by Underwriters Laboratories Inc.®in accordance with the Standard(s) indicated on this Certificate. Standard(s)for Safety: ANSI/UL 1479, ANSI/UL 2079, CAN/ULC-S 115-05 Additional Information: FS-ONE Sealant for use in Joint Systems and FS-ONE for use in Through- Penetration Firestop Systems as currently described in the UL Fire Resistance Directory. Only those products bearing the UL Classification Mark should be considered as being covered by UL's Classification and Follow-Up Service. The UL Classification Mark includes: UL in a circle symbol: t with the word "CLASSIFIED" (as shown); a control number (may be alphanumeric) assigned by UL; a statement to indicate the extent of UL's evaluation of the product;and, the product category name(product identity)as indicated in the appropriate UL Directory. Look for the UL Classification Mark on the product ettouloute ssued by�IBt{t� Reviewed by: Christopher fison Underwriters Laboratories Inc. Underwriters L .oratories Inc. 104 I liar I Hilti North America 5400 South 122nd East Avenue Tulsa,OK 74146 P.O.Box 21148 I Tulsa,OK 74121-1148 T 1-800-879-8000 I F 918-252-6742 www.hilti.com June 27, 2008 To Whom It May Concern: Re: Hilti FS-ONE Intumescent Firestop The Hilti FS-ONE Intumescent Firestop is manufactured in Kaufering, Germany. The FS-ONE pail is made of polyethylene and can be completely recycled. There is no post- consumer or post-industrial content in FS-ONE and it cannot be recycled. The VOC content for FS-ONE is 75 grams/liter. FS-ONE is not regulated as a hazardous waste by the Federal EPA Standards. The regulations for the disposal of non-regulated industrial waste can vary from state to state and even city to city. For this reason, you should consult your local and state regulatory agencies for direction on disposal. Please feel free to contact me at (918) 252-6704 if you have questions. Sincerely, Jerry Metcalf MPH, CHMM Safety/Environmental Manager Hilti Inc (918) 252 6704 lerry.metcalfc hilti.com NOTES/DEFINITIONS: 1. Post-Consumer Recycled Content: Portion of material or product derived from discarded consumer waste that has been recovered for use as a raw material[e.g.,plastic bottles, newspaper] 2. Post-Industrial Recycled Content: Portion of material or product derived from recovered industrial and mfg.materials that are diverted from municipal solid waste for use in a different mfg.process,prior to use by a consumer[e.g.,fly-ash in concrete or synthetic gypsum board,both of which are by-products of coal-burning power plants]. Spills and scraps from the original manufacturing process that are combined with other constituents after a minimal amount of reprocessing for use in further production of the same product do not qualify. 3. Manufactured: Final assembly of components into building product that is furnished and installed by trades[e.g.,if the hardware comes from Dallas,TX,the lumber from Keene, NH,and the joist is assembled in Kent,WA;then the location of final assembly is Kent,WA]. www.gpsvisualizer.com/calculators can be used to calculate straight-line distance between project site/New York,NY and location of manufacture and raw material source. Note:location noted on material data sheets is often corporate location;need manufacturer to verify actual manufacture location. 4. Raw Materials: Virgin or recovered resources from which the product's components are made[i.e.,before processing or manufacturing]. 5. Rapidly Renewable: Materials and products made from raw materials that are harvested within a 10-year cycle[e.g.,bamboo,cork,linoleum,fast-growing poplar,wheatboard,wool carpet]. 6. FSC Certified: Wood-based products that are certified by the Forest Stewardship Council and carry a Chain-of-Custody certificate number from the vendor or manufacturer. 7. VOC Content: The quantity of volatile organic compounds contained in products such as adhesives,sealants and architectural coatings.VOC content is to be reported in grams/liter or lbs/gallon,less water and any exempt compounds/solvents. CONTRACTOR CERTIFICATION: I, a duly authorized representative of hereby certify that the information contained herein accurately represents the listed"green building"characteristics of the material to be provided by our company as components of the building construction. Furthermore, I understand that any change in such"green building"material characteristics during the purchasing and/or installation period will require prior written approval from the Construction Manager and Owner. SIGNATURE OF AUTHORIZED REPRESENTATIVE: DATE: p. of MSDS No.: 259 111*1111111.1911MI Revision No.: 010 Revision Date: 08/17/04 ® Page: 1 of 2 MATERIAL SAFETY DATA SHEET Product name: FS-ONE High Performance Intumescent Firestop Sealant Description: One-part acrylic-based sealant Supplier: Hilti, Inc. P.O. Box 21148,Tulsa, OK 74121 Emergency#(Chem-Trec.): 1 800 424 9300(USA, PR,Virgin Islands, Canada);001 703 527 3887(other countries) INGREDIENTS AND EXPOSURE LIMITS ril redie lte -- g , ...#neer:. : ' �� ,� � .� ,.'TLV: Polyacrylate dispersion Mixture NE NE NE Calcium carbonate 001317-65-3 5 mg/m3(T) 10 mg/m3(T) NE Zinc borate 138265-88-0 NE NE NE Ammonium polyphosphate 068333-79-9 NE NE NE Talc 014807-96-6 20 mppcf 2 mg/m3 NE Expandable graphite 012777-87-6 5 mg/m3(T) 2 mg/m3(T) NE Ethylene glycol 000107-21-1 NE C:100 mg/m3(A) NE Polybutene 009003-29-6 NE NE NE Iron oxide 001309-37-1 10 mg/m3 5 mg/m3 NE Glass filament 065997-17-3 NE 5 mg/m3(T) NE Silicon dioxide 014808-60-7 0.05 mg/m3(T) 0.1 mg/m3(T) NE Water 007732-18-5 NE NE NE Abbreviations: PEL=OSHA Permissible Exposure Limit. TLV=ACGIH Threshold Limit Value. C=Ceiling. STEL= Short Term Exposure Limit. NE=None Established. NA=Not Applicable. (T)indicates"as total dust". (R)indicates"as respirable fraction". (A) indicates"as an aerosol". mppcf=million particles per cubic foot. PHYSICAL DATA Appearance: Red paste. Odor. Odorless. Vapor Density: (air=1) Not determined. Vapor Pressure: 23mbar @ 20C/68F Boiling Point: Not applicable. VOC Content: 75.0 g/L. Evaporation Rate: Not applicable. Solubility in Water: Soluble. Specific Gravity: 1.5 pH: Not determined. FIRE AND EXPLOSION HAZARD DATA Flash Point: Non-flammable. Flammable Limits: Not applicable. Extinguishing Media: Not applicable. Use extinguishing media as appropriate for surrounding fire. Special Fire Fighting None known. Use a self-contained breathing apparatus when fighting fires involving chemicals. Procedures: Unusual Fire and Explosion None known. Thermal decomposition products can be formed such as oxides of carbon, sulfur Hazards: and phosphorous. REACTIVITY DATA Stability: Stable. Hazardous Polymerization: Will not occur. Incompatibility: Strong acids, peroxides,and oxidizing agents. Decomposition Products: Thermal decomposition can yield CO and CO2. Conditions to Avoid: None known. HEALTH HAZARD DATA Known Hazards: None known. Signs and Symptoms of Possibly irritating upon contact with the eyes or upon repeated contact with the skin. Exposure: Medical Conditions Eye and skin conditions. Aggravated by Exposure: Routes of Exposure: Dermal. HILTI®is a registered trademark of Hilti Corp. Carcinogenicity: IARC classifies crystalline silica(quartz sand)as Group I based upon evidence among workers in - industries where there has been long-term and chronic exposure (via inhalation) to silica dust; e.g. mining, quarry, stone crushing, refractory brick and pottery workers. This product does not pose a dust hazard; therefore, this classification is not relevant. Based upon the nature and - intended use of this product, it does not pose an increased cancer risk to workers. EMERGENCY AND FIRST AID PROCEDURES prpyes: eh- , Immediately flush with plenty of water. Call a physician if symptoms occur. r Skin: - Immediately wipe off material and wash with soap and water. Material can adhere to the skin. If material has adhered to the skin, use an abrasive containing hand cleaner. If material does not come off, buff with a pumice stone. inhalation: Move victim to fresh air if discomfort develops. Call a physician if symptoms persist. Ingestion: Seek medical attention. Do not induce vomiting unless directed by a physician. If a large quantity . was ingested, give 1 to 2 glasses of water to dilute. Never give anything by mouth to an - unconscious person. Other: Referral to a physician is recommended if there is any question about the seriousness of the injury/exposure. CONTROL MEASURES AND PERSONAL PROTECTIVE,EOUIPMENT Ventilation: General(natural or mechanically induced fresh air movements). F,Eye Protection: Not required, however,safety glasses should be worn in most industrial settings. Skin Protection: Avoid skin contact.Cloth gloves are suitable for hand protection. Respiratory Protection: None normally required. Where ventilation is inadequate to control vapors, use a NIOSH- ' approved respirator with organic vapor cartridges. Never enter a confined space without an appropriate air-supplied respirator. PRECAUTIONS FOR SAFE HANDLING AND USE Handling and Storing Store in a cool, dry area preferably between 40°and 77° F. Keep from freezing. Do not store in Precautions: direct sunlight. Avoid contact with the eyes or skin. Practice good hygiene; i.e. always wash thoroughly after handling and before eating or smoking. For industrial use only. Keep out of reach of children. Follow label/use instructions. Spill Procedures: Immediately wipe away spilled material before it hardens. Place in a container for proper disposal in accordance with all applicable local, state,or federal requirements. Hazard Communication: This MSDS has been prepared in accordance with the federal OSHA Hazard Communication Standard 29 CFR 1910.1200. HMIS Codes: Health 1, Flammability 0, Reactivity 0, PPE B DOT Shipping Name: Not regulated. IATA/ICAO Shipping Name: Not regulated. TSCA Inventory Status: Chemical components listed on TSCA inventory. SARA Title III,Section 313: This product contains < 3% ethylene glycol (CAS 107-21-1) and < 15% zinc borate (re: zinc compounds) which are subject to reporting under Section 313 of SARA Title III (40 CFR Part 372). EPA Waste Code(s): Not regulated by EPA as a hazardous waste. Waste Disposal Methods: Consult with regulatory agencies or your corporate personnel for disposal methods that comply :1, with local,state,and federal safety, health and environmental regulations. CONTACTS 1 800 879 8000 Technical Service. ��� w 1 800 879 8000 Health/Safety: 100879800 Jerry Metcalf (x6704) 1 800 424 9300(USA, PR,Virgin Islands, Canada); 001 703 527 3887(other countries) The information and recommendations contained herein are based upon data believed to be correct; however, no guarantee or warranty of any kind expressed or implied is made with respect to the information provided. MSDS 259, Page 2 of 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION `CAL--��t, OFFICE OF THE STATE FIRE MARSHAL FIRE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE .,/ LISTING No. 4485-1200:108 Page 1 of 1 CATEGORY: Opening Protection (Firestopping) LISTEE: Hilti, Inc., 5400 S. 122nd East Ave, Tulsa, OK 74146 Contact: *Clay Hensley(918)252-6216 Fax(918)254-1679 DESIGN: Model FS-ONE Firestop Sealant. Refer to listee's printed data sheet and UL Fire Resistance Directory for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes &ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, type identification and UL label. APPROVAL: Listed as firestop devices for use in through-penetration firestop system up to 3 hour rating. For indoor use only. Approved under Through-Penetration Fire Stop Systems: CAJ1155, CAJ2091, CAJ2118, CAJ3095, CAJ5044, CAJ8041, F-C-2025, WL1085, WL1056, WL3047, WL5029, WL8004. Refer to UL Fire Resistance Directory for detailed constructions. *Rev.06-20-2006 y®,,,E This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results r and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation I ..I criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 10, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division Report of Materials and xBUILDINGS Equipment Acceptance Division NYC Department of Buildings 280 Broadway, New York,NY 10007 Patricia Lancaster, FAIA,Commissioner (212)566-5000,TTY:(212)566-4769 Pursuant to Administrative Code Section 27-131, the following equipment or material has been found acceptable for use subject to the terms and conditions contained herein. MEA 326-96-M Vol. 5 Manufacturer: Hilti, Inc., 5400 S. 122 East Avenue, Tulsa, OK 74146 Trade Name(s): Hilti, Inc. Product: Fill, void or cavity material for fire protection Pertinent Code Section(s): 27-345 Prescribed Test(s): RS 5-19 (ASTM E814), UL 2079 Laboratory: Underwriters Laboratories, Inc. Test Report(s): File R13240, dated July 16, 1993, July 21, 1993, July 13, 1993, July 22, 1993, April 1, 1993, March 25, 1994, March 3 and 6, 1995, September 4, 1996, September 27, 1997; File R13644, dated April 12, 1993 and May 3, 1993; File R12232, dated August 2, 1993; UL-design listings. Description: Fill, void or cavity material for through-penetrations in fire-rated wall and/or floor/ceiling construction. The Hilti FS-ONE Firestop Sealant shall be applied in accordance with Underwriters Laboratories Inc. system numbers, listed on following pages, in achieving the required fire-resistance ratings. MEA 326-96-M Vol.5 Page 1 of 10 DELTA INC1 FIRE PROTECTION CONTRACTORS 14795 S. .72nd, ?ORi1A1@,OR 91724 (503)620-4020 DeltaFire, Inc 14795 Sw 72nd Ave Portland, OR 97224 503-620-4020 Job Name : Burnham &Ash Apartments Building : BUILDING 2 Location : Burnham st&Ash ave, Tigard OR 97223 System : 5 Contract : 15-5481 Data File : 155481-BHAA-FP-RevO Area 5.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C DeltaFire, Inc Page 1 Burnham&Ash Apartments Date 3/11/2016 City Water Supply: Demand: Cl -Static Pressure : 104 D1 -Elevation : 5.570 C2-Residual Pressure: 92 D2-System Flow : 912.83 C2-Residual Flow : 1610 D2 -System Pressure : 94.984 Hose( Demand) : 250 D3-System Demand : 1162.83 Safety Margin : 2.443 150 E 140 130 P 120 R 110 . ci E 100 D� C2 S 90 D3 S 80 L U 70 R 60 E 50 40 30 20 10 j 200 400 600 800 1000 1200 1400 1600 1800 FLOW( NA1.85 ) • Computer Programs by Hydratec Inc. Route 111 Windham N.H.USA 03087 Fittings Used Summary DeltaFire, Inc Page 2 Burnham&Ash Apartments Date 3/11/2016 Fitting Legend Abbrev. Name % % 1 1% 1% 2 2% 3 3% 4 5 6 8 10 .__12 14 16 18 20 24 Bvcb B Fly Vic 705W 0 0 0 0 0 0 5 5 0 12 12 8 11 12 14 0 0 0 0 0 E NFPA 13 90'Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Fsp Flow Switch Potter VSR Fitting generates a Fixed Loss Based on Flow T NFPA 13 90'Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 1 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with*. The fittings marked with a *show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a*will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. • Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 vressure / How summary - s I ANUAKU DeltaFire, Inc Page 3 Burnham &Ash Apartments Date 3/11/2016 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual _ Actual Req. 285 11.92 11.2 11.58 na 38.11 0.15 60 7.0 134 10.92 13.3 na 135 10.92 18.01 na 136 10.89 20.75 na 137 10.86 24.48 na 138 10.83 25.9 na 139 9.83 34.87 na 140 9.82 35.05 na 141 9.8 36.39 na 142 9.77 39.41 na 143 9.73 44.95 na 144 3.0 81.99 na 145 -3.5 94.69 na HOSE -3.5 95.73 na 250.0 TEST 0.0 94.98 na 286 11.92 11.2 12.35 na 39.35 0.15 85 7.0 146 10.92 14.14 na 147 10.92 17.79 na 287 12.85 11.2 15.68 na , 44.36 0.15 120 7.0 151 11.85 17.82 na 152 11.85 24.64 na 150 11.85 25.52 na 149 9.85 34.84 na 288 11.89 11.2 16.7 na 45.77 0.15 130 7.0 289 11.83 11.2 18.05 na 47.59 0.15 130 7.0 148 10.83 20.43 na 290 12.82 11.2 18.04 na 47.57 0,15 100 7.0 153 11.82 20.41 na 154 11.82 29.12 na 291 12.88 11.2 18.35 na 47.97 0.15 60 7.0 156 11.88 20.75 na 157 11.88 26.55 na 158 11.86 27.16 na 159 11.82 30.13 na 160 11.8 31.27 na 292 11.86 11.2 19.82 na 49.86 0.15 130 7.0 293 12.86 11.2 19.1 na 48.95 0.15 102 19.1 161 11.86 21.58 na 294 12.82 11.2 19.35 na 49.27 0.15 200 7.0 155 11.82 21.86 na 295 12.85 11.2 19.95 na 50.02 0.15 120 7.0 296 12.8 11.2 21.96 na 52.48 0.15 154 7.0 162 11.8 24.71 na 297 12.82 11.2 24.54 na 55.48 0.15 200 7.0 298 13.77 11.2 24.14 na ' 55.03 0.15 238 19.1 163 11.77 28.39 na 164 11.77 35.5 na 299 13.83 11.2 26.37 na 57.51 0.15 102 19.1 165 11.83 33.67 na 166 11.79 34.8 na 300 13.79 11.2 27.3 na 58.52 0.15 238 19.1 301 13.8 11.2 30.6 na 61.96 0.15 102 19.1 167 11.8 38.85 na 168 11.76 40.16 na 169 11.74 40.95 na 302 13.76 11.2 31.67 na 63.03 0.15 238 19.1 The maximum velocity is 23.4 and it occurs in the pipe between nodes 302 and 168 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 anal Latculations - riazen-vvllnams DeltaFire, Inc Page 4 Burnham &Ash Apartments Date 3/11/2016 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes . Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 285 38.11 1.049 E 2.0 1.000 11.576 K Factor= 11.20 to 120.0 0.0 2.000 0.433 134 38.11 0.4287 0.0 3.000 1.286 Vet= 14.15 134 0.0 1.049 T 5.0 6.000 13.295 to 120.0 0.0 5.000 0.0 135 38.11 0.4289 0.0 11.000 4.718 Vel= 14.15 135 39.35 1.38 0.0 6.500 18.013 to 120.0 0.0 0.0 0.013 136 77.46 0.4189 0.0 6.500 2.723 Vel= 16.62 136 45.77 1.61 0.0 7.970 20.749 to 120.0 0.0 0.0 0.013 137 123.23 0.4670 0.0 7.970 3.722 Vel= 19.42 137 49.86 2.067 0.0 5.430 24.484 to 120.0 0.0 0.0 0.013 138 173.09 0.2591 0.0 5.430 1.407 Vel= 16.55 138 47.59 2.067 21 20.0 1.000 25.904 to 120.0 0.0 20.000 0.433 139 220.68 0.4064 0.0 21.000 8.534 Vel= 21.10 139 94.38 4.26 0.0 7.700 34.871 to 120.0 0.0 0.0 0.004 140315.06 0.0232 0.0 7.700 0.179 Vel= 7.09 140 _ 96.84` 4.26 T 26.334 8.490 35.054 to 120.0 0.0 26.334 0.009 141_ 411.9 0.0381 0.0 34.824 1.326 Vel= 9.27 141 204.88 4.26 E 13.167 24.290 36.389 to 120.0 0.0 13.167 0.013 142 616.78 0.0804 0.0 37.457 3.011 Vel= 13.88 142 171.06 4.26 T 26.334 17.290 39.413 to 120.0 0.0 26.334 0.017 143 787.84 0.1264 0.0 43.624 5.515 Vel= 17.73 143 124.99 4.26 2E 26.334 119.020 44.945 to 120.0 T 26.334 68.468 5.915 ** Fixed Loss= 3 144 912.83 0.1660 Bvcb 15.8 187.488 31.126 Vet= 20.55 ---1--44- - Fsp 0.0 - 0.0 4.26 E 13.167 10.250 81.986 to 120.0 0.0 13.167 8.815 ** Fixed Loss =6 145 912.83 0.1660 0.0 23.417 3.888 Vel = 20.55 145 0.0 6.16 2E 40.168 10.000 94.689 to 140.0 0.0 40.168 0.0 HOSE _ 912.83 0.0207 0.0 50.168 1.039 Vel= 9.83 HOSE 250.00 8.27 0.0 100.000 95.728 Qa=250 to 140.0 0.0 0.0 -1.516 TEST 1162.83 0.0077 0.0 100.000 0.772 Vel= 6.95 0.0 1162.83 94.984 K Factor= 119.31 286 39.35 1.049 E 2.0 1.000 12.345 K Factor= 11.20 to 120.0 0.0 2.000 0.433 146 39.35 0.4553 0.0 3.000 1.366 Vel = 14.61 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 rinat uaicuiations - riazen-vviiiiams DeltaFire, Inc Page 5 Burnham &Ash Apartments Date 3/11/2016 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 146 0.0 1.049 E 2.0 6.000 14.144 to 120.0 0.0 2.000 0.0 147 39.35 0.4551 0.0 8.000 3.641 Vel= 14.61 147 0.0 1.049 0.0 0.500 17.785 to 120.0 0.0 0.0 0.0 135 39.35 0.4560 0.0 0.500 0.228 Vel = 14.61 0.0 39.35 18.013 K Factor= 9.27 287 44.36 1.049 E 2.0 1.000 15.684 K Factor= 11.20 to 120.0 0.0 2.000 0.433 151 44.36 0.56800.0 3.000 1.704 Vel= 16.47 151 0.0 1.049 0.0 12.000 17.821 to 120.0 0.0 0.0 0.0 152 44.36 0.5680 0.0 12.000 6.816 Vel= 16.47 152 50.02 1.38 0.0 1.460 24.637 to 120.0 0.0 0.0 0.0 150 94.38 0.6034 0.0 1.460 0.881 Vel= 20.24 150 0.0 1.38 2T 12.0 2.000 25.518 to 120.0 0.0 12.000 0.866 149 94.38 0.6039 0.0 14.000 8.455 Vel= 20.24 _ 149 0.0 4.26 0.0 9.470 34.839 to 120.0 0.0 0.0 0.009 139 94.38 0.0024 0.0 9.470 0.023 Vel= 2.12 - 0.0 94.38 34.871 K Factor= 15.98 288 45.77 1.049 T ` 5.0 1.000 16.704 K Factor= 11.20 to 120.0 0.0 5.000 0.433 136 45.77 0.6020 0.0 6.000 3.612 Vel= 16.99 0.0 45.77 20.749 K Factor= 10.05 289 47.59 1.049 E 2.0 1.000 18.052 K Factor= 11.20 to 120.0 0.0 2.000 0.433 148 47.59 0.6470 0.0 3.000 1.941 Vel= 17.67 148 0.0 1.049 0.0 8.470 20.426 to 120.0 0.0 0.0 0.0 138 47.59 0.6468 0.0 8.470 5.478 Vet= 17.67 0.0 47.59 25.904 K Factor= 9.35 290 47.57 1.049 E 2.0 1.000 18.040 K Factor= 11.20 to 120.0 0.0 2.000 0.433 153 47.57 0.6467 0.0 3.000 1.940 Vel= 17.66 153 0.0 1.049 T 5.0 8.470 20.413 to 120.0 0.0 5.000 0.0 154 47.57 0.6465 0.0 13.470 8.708 Vel= 17.66 154 49.27 1.38 T 6.0 2.000 29.121 to 120.0 0.0 6.000 0.866 140 96.84 0.6334 0.0 8.000 5.067 Vel= 20.77 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Anal calculations - tiazen-vvuuams DeltaFire, Inc Page 6 Burnham &Ash Apartments Date 3/11/2016 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes +"""' Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 96.84 35.054 K Factor= 16.36 291 47.97 1.049 E 2.0 1.000 18.346 K Factor= 11.20 to 120.0 0.0 2.000 0.433 156 47.97 0.6567 0.0 3.000 1.970 Vel = 17.81 156 0.0 1.049 T 5.0 3.830 20.749 to 120.0 0.0 5.000 0.0 157 47.97 0.6565 0.0 8.830 5.797 Vel= 17.81 157 0.0 1.38 0.0 3.500 26.546 to 120.0 0.0 0.0 0.009 158 47.97 0.1726 0.0 3.500 0.604 Vel= 10.29 158 48.95 1.61 0.0 9.860 27,159 to 120.0 0.0 0.0 0.017 159 96.92 0.2995 0.0 9.860 2.953 Vel = 15.27 159 55.48 2.067 0.0 5.540 30.129 to 120.0 0.0 0.0 0.009 160 152.4 0.2049 0.0 5.540 1.135 Vel= 14.57 160 52.48 2.067 T 10.0 2.000 31.273 to 120.0 0.0 10.000 0.866 141 204.88 0.3542 0.0 12.000 4.250 Vel = 19.59 0.0 204.88 36.389 _ K Factor= 33.96 292 49.86 1.049 T 5.0 1.000 19.819 K Factor= 11.20 to 120.0 0.0 5.000 0.433 137 49.86 0.7053 0.0 6.000 4.232 Vel = 18.51 0.0 49.86 24.484 K Factor= 10.08 293 48.95 1.049 E 2.0 1.000 19.100 K Factor= 11.20 to 120.0 0.0 2.000 0.433 161 _ 48.95 0.6817 0.0 3.000 2.045 Vel= 18.17 161 0.0 1.049 T 5.0 3.190 21.578 to 120.0 0.0 5.000 0.0 158 48.95 0.6814 0.0 8.190 5.581 Vel = 18.17 0.0 48.95 27.159 K Factor= 9.39 294 49.27 1.049 E 2.0 1.000 19.353 K Factor= 11.20 to 120.0 0.0 2.000 0.433 155 49.27 0.6900 0.0 3.000 2.070 Vel= 18.29 155 0.0 1.049 T 5.0 5.530 21.856 to 120.0 0.0 5.000 0.0 154 49.27 0.6899 0.0 10.530 7.265 Vel= 18.29 0.0 49.27 29.121 K Factor= 9.13 295 50.02 1.049 T 5.0 1.000 19.947 K Factor= 11.20 to 120.0 0.0 5.000 0.433 152 50.02 0.7095 0.0 6.000 4.257 Vel= 18.57 0.0 50.02 24.637 K Factor= 10.08 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 rinai uatcutations - riazen-vvuhams DeltaFire, Inc Page 7 Burnham &Ash Apartments Date 3/11/2016 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 296 52.48 1.049 E 2.0 1.000 21.955 K Factor= 11.20 to 120.0 0.0 2.000 0.433 162 52.48 0.7753 0.0 3.000 2.326 Vel= 19.48 162 0.0 1.049 0.0 8.460 24.714 to 120.0 0.0 0.0 0.0 160 52.48 0.7753 0.0 8.460 6.559 Vet= 19.48 0.0 52.48 31.273 K Factor= 9.38 297 55.48 1.049 T 5.0 1.000 24.540 K Factor= 11.20 to 120.0 0.0 5.000 0.433 159 55.48 0.8593 0.0 6.000 5.156 Vel= 20.60 0.0 55.48 30.129 K Factor= 10.11 298 55.03 1.049 E 2.0 2.000 24.141 K Factor= 11.20 to 120.0 0.0 2.000 0.866 163 55.03 0.8465 0.0 4.000 3.386 Vel= 20.43 163 0.0 1.049 0.0 8.400 28.393 to 120.0 0.0 0.0 0.0 164 _ 55.03 0.8464 0.0 8.400 7.110 Vet= 20.43 164 116.03 2.067 T 10.0 2.000 35.503 to 120.0 0.0 10.000 0.866 142 171.06 0.2537 0.0 12.000 3.044 Vel= 16.36 0.0 171.06 39.413 K Factor= 27.25 299 57.51 1.049 T 5.0 2.000 26.370 K Factor= 11.20 to 120.0 0.0 5.000 0.866 165 57.51 0.9184 0.0 7.000 6.429 Vet= 21.35 165 0.0 1.61 0.0 9.800 33.665 to 120.0 0.0 0.0 0.017 166 57.51 0.1141 0.0 9.800 1.118 Vel= 9.06 166 58.52 2.067 0.0 5.610 34.800 to 120.0 0.0 0.0 0.009 164 116.03 0.1237 0.0 5.610 0.694 Vel= 11.09 0.0 116.03 35.503 K Factor= 19.47 300 58.52 1.049 T 5.0 2.000 27.296 K Factor= 11.20 to 120.0 0.0 5.000 0.866 166 58.52 0.9483 0.0 7.000 6.638 Vel= 21.72 0.0 58.52 34.800 K Factor= 9.92 _ 301 61.96 1.049 T 5.0 2.000 30.603 K Factor= 11.20 to 120.0 0.0 5.000 0.866 167 61.96 1.0541 0.0 7.000 7.379 Vel= 23.00 167 0.0 1.61 0.0 9.860 38.848 to 120.0 0.0 0.0 0.017 168 61.96 0.1308 0.0 9.860 1.290 _ Vel= 9.76 168 63.03 2.067 0.0 5.550 40.155 to 120.0 0.0 0.0 0.009 169 124.99 0.1420 0.0 5.550 0.788 Vel= 11.95 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams DeltaFire, Inc Page 8 Burnham &Ash Apartments Date 3/11/2016 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 16.9 0.0 2.067 2T 20.0 2.000 40.952 to 120.0 0.0 20.000 0.871 143 124.99 0.1419 _ 0.0 22.000 3.122 Vel = 11.95 0.0 124.99 44.945 K Factor= 18.64 302 63.03 1.049 T 5.0 2.000 31.672 K Factor= 11.20 to 120.0 0.0 5.000 0.866 168 63.03 1.0881 0.0 7.000 7.617 Vel= 23.40 0.0 — 63.03 40.155 K Factor= 9.95 Computer Programs by Hydratec inc. Route 111 Windham N.H.'USA 03087