Loading...
Plans (3) BtP2013 - 00258 #3082 G,o RECEIVED MARTIN W. HANSON ��o TENANT IMPROVEMENT OCT 23 2013 cuA KAM S, OREGON,1 � o ti CITY OF TIGARD ��� J \� PROJECT LOCATION ��� for PLANNING/ENGINEERING O F PROJECT #13560 SW 72ND AVENUE Z J CONSa UMER ECELLULARW F _ INCORPORATED N w Q8 RR ERN P P(✓`F�C CONSOLIDATED UmT7URa UTT/ D PROJECT NARRATIVE H PROJECT CONSISTS OF EXPANSION OF EXISTING OFFICE SPACE INTO EXISTING Q $ BURLINGTON NORTHERN RR WAREHOUSE. CONSTRUCTION OF 5,684 SF OF ADDITIONAL OFFICE SPACE WORK SHALL SW 74TH AVENUE INCLUDE BUT NOT BE LIMITED TO DRYWALUMETAL STUDS, SUSPENDED CEILINGS, DOORS/FRAMES AND PAINTING. ALL WORK TO MEET ADA REQUIREMENTS. �"N I•� o g� 1 LOCATION MAP Z WORK INCLUDED BUT PERFORMED UNDER SEP. PERMIT 5+0 Wn w N NOT TO SCALE [••1 `o�0 FIRE PROTECTION SPRINKLERING c 0 0 kn HEATING, in a - VENTILATION & AIR CONDITIONING WORK � a o se c D of F (03 OH o� J oK Mj N gyp) ELECTRICAL WORK, BOTH LINE VOLTAGE AND LOW VOLTAGE �K rr rr rr r{ rr rr rJ. s4 rr r r{ Ibp • BUILDING INFORMATION TENANT USAGE W OWNER: PACIFIC REALTY ASSOCIATES, L.P. TENANT WILL BE STORING CELL PHONES ^ W $ 15350 SW SEQUOIA PKWY #300 AND PREPARING PACKAGES FOR a -- - --- ---} - -1 — ---- — -- -- --- -- --- ---4---- - --- - }--------4---- - PORTLAND, ORE 97224 DELIVERY TO COSTUMERS. �a O 4 a (503) 624-6300 (PHONE) O Q O- — - —-- — — ---— —-- ——— ---- - -- - - T----- -------- ---— -——--}------ -- (503) 624-7755 (FAX) � 4 AREA OF WORK BLDG. #: OBP III BLDG. I (3obp219) a- - - --- - — - ---- -- -- -- -- - -- - ----- ---------- --- ---- -- - --4--- Q A TENAI T SPACE I CONST. TYPE.: III-B 4 O- - - — - — ------- ----- ------ ------ - -- - - -------- -------- ----- --- ---- — - THIS BUILDING HOUSES SEVERAL SEPARATE TENANTS INCLUDING THIS TENANT. THE EXISTING BUILDING IS TWO SEPARATE BUILDINGS SEPARATED BY AN EXISTING 4-HR. BLDG. SEPARATION WALL. BUILDING A IS PRIMARILY A SINGLE STORY BUILDING OF © - - -- 69,737 SF AND IS FULLY SPRINKLERED (2,600 SF OF UNUSED SECOND STORY SPACE). �■ �� �■ BLDG. B IS PRIMARILY A SINGLE STORY BUILDING 56,970 SF AND IS FULLY SPRINKLERED AREA OF WORK (4,759 SF OF SECOND STORY SPACE). THERE IS FRONTAGE ON THREE SIDES OF AT BUILDINGS BUILDINGA LEAST 60 FEET. 2 OVERALL BUILDING PLAN Z ACTUAL BUILDING A AREA TOTALS ACTUAL BUILDING B AREA TOTALS I0=4 A-1 Ito=bot B OCCUPANCY = 2,636 SF EXISTING B OCC. - 10,139 SF 0=4 S2 OCCUPANCY = 67 101 SF EXPAN. B OCC. = 5,684 SF TOTAL B OCC. = 15,823 SF ---1-4— aai —1-4— Y44--f- it � � ¢ k~�g � TOTAL 69 737 SF i t t a i i ill a t M i ill;, t, t iataaiitai aaiiiatt i , ° .o 0 0 - ADJUSTED S2 OCC. _ _41,147 SF MIXED OCCUPANCY NON-SEPARATED F+� USES. (IBC 508.3.2) TOTAL 56,970 SF a N ALLOWABLE AREA (B MOST RESTRICTIVE) MIXED OCCUPANCY - NON-SEPARATED �' Q a USES. (IBC 508.3.2) o B 19,000 + 57,000 (300% SPRINKLER - INCREASE) = 76,000 SF. ALLOWABLE AREA B MOST RESTRICTIVE 0 zw z 3 69,737 SF < 76,000 SF - NON-SEPARATED B 19,000 + 57,000 (300% SPRINKLER a O p a, ° OCCUPANCY ALLOWED INCREASE) 76,000 SF. REVISION TENANT INFORMATION 56,970 SF < 76,000 SF - NON-SEPARATED 1 TENANT: CONSUMER CELLULAR OCCUPANCY ALLOWED 2 ° ° ° ° 3. OCCUPANCY AREAS & LOADS: 4. B 10,139 SF 102 OCC CITY Of TIGARD 5. S-2 46,831 SF 94 OCC Approved.........1..t.................. Conditionally Approved..............[ Approved plans 6' TOTAL 56,970 SF 196 OCC See Letter to:Follow..................[ shall be on job site. 134261-3-do, :...PxAttached....... NUMBER OF EXITS REQUIRED PermitNumb r. ►3-oo�sp� ] B 2 EXIT, 2 PROVIDED Ad • Date: zz OFFICE COPY S-2 2 EXITS, 6 PROVIDED ocr ;C DATE 9/30/13 Occupancy Low PERMIT SET Construction Type Rated Corridot 3 EXIT PLAN Energy Code 1ta=Sot Z Accessibility A-1 INDICATES EGRESS LIGHTING 1� O� BUILDE4G DEPARTMENT USE 0100 00 GENERAL DATA PSI)G60. d. HANGERS 12 GAUGE WIRE OR 18-GAUGE V WIDE STRAP. EXPOSED DUCT MUST HAVE ALL THREAD GENERAL REQUIREMENTS 4. PROVIDE THE LISTED GYPSUM BOARD PRODUCTS BY U.S.GYPSUM,GEORGIA PACIFIC,NATIONAL GYPSUM OR HANGERS AND FULL DIAMETER STRAP UP TO 18"0. LARGER THAN 18"MUST HAVE SADDLE TYPE AN APPROVED EQUAL. CLAMP. 1. ALL CONSTRUCTION WORK SHALL BE DONE IN COMPLIANCE WITH THE LATEST EDITION OF THE OREGON 5. STANDARD GYPSUM BOARD SHALL BE TYPE'X',5(8"THICK WITH TAPERED EDGES CONFORMING TO ASTM e. BRANCH DUCTS SHALL BE PLUMB AND SQUARE(NO OCTOPUS). TEES SHALL BE MAXIMUM OF 45 STRUCTURAL SPECIALTY CODE,AND ALL OTHER STATE OR LOCAL CODE REQUIREMENTS THAT APPLY. C-36DEGREES. #3082 2. VERIFY ALL DIMENSIONS AND CON DITIONS SHOWN ON DRAWINGS AND AT THE EXISTING BUILDING AND 6. WATER RESISTANT GYPSUM BOARD SHALL BE 5/8"THICK WITH TAPERED EDGES. CONFORMING TO ASTM f. EACH BRANCH DUCT TO HAVE BALANCE DAMPER IN Y BRANCH. BLDG.STRUCTURE ABOVE NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO STARTING THE WORK. C-630CAULKING IN 1/2' SPACE MARTIN W. HANSON 3. CONTRACTOR AND ALL SUBCONTRACTORS SHALL PERFORM DUE DILIGENCE INSPECTION OF ALL EXISTING y. ALL DISTRIBUTION DUCT WORK TO BE INSTALLED MIN.24"ABOVE FINISH CEILING. CONDITIONS PRIOR TO SUBMITTAL OF A PROPOSAL.SUBMITTAL OF A PROPOSAL SHALL BE CONSIDERED 7. AT TOILET ROOMS USE 5/8"USG FIBERROCK BRAND AQUATOUGH INTERIOR PANEL FROM FLOOR T048"A.F.F. 18.FLEX DUCT WILL BE NO LONGER THAN 6'FROM RIGID DUCT DOWN TO DIFFUSER. DEFLECTION CHANNEL CONFIRMATION THAT SUCH INSPECTION HAS BEEN MADE,AND NO FURTHER COMPENSATION SHALL BE DUE LO WALLS BEHIND OR ADJACENT LA PLUMBING FIXTURES. NO SUBSTITUTES.(EXCEPTION:EXCEPTION AT CLA KAM S, OREGON THE CONTRACTOR FOR CLAIMS ARISING AS A RESULT OF FAILURE TO PERFORM SUCH INSPECTION. LOCATIONS TO RELIEVE PLASTIC LAMINATE OR TILE WAINSCOT.) 19.DIFFUSERS: 4. BY SUBMITTING A PROPOSAL,CONTRACTOR AND ALL SUBCONTRACTORS CERTIFY THAT THEY HAVE 8. AT TILE WAINSCOT LOCATIONS INSTALL CEMENT BACKER BOARD'/"THICK WITH SQUARE,REINFORCED, a. SUSPENDED CEILING SYSTEM(f-BAR)-PERFORATED FACE ADJUSTABLE CURVED BLADES-DESIGN EXAMINED THE SITE AND INCLUDED IN THEIR PROPOSAL ALL WORK NECESSARY TO COMPLETE THE WORK SMOOTH EDGES. PROVIDE DUROCK BRAND CEMENT BOARD OR APPROVED EQUAL. TITUS PCS SUPPLY AND TITUS PAR RETURN OR APPROVED EQUAL. DESCRIBED OR REASONABLY IMPLIED IN THESE DOCUMENTS. THIS INCLUDES BUT MAY NOT BE LIMITEDTO 9. AT FRP,PLASTIC LAMINATE,ETC.,WAINSCOT PANELING INSTALL WATER-RESISTANT GYPSUM BOARD. b. GYP.BD.CEILING;SUPPLY-CURVED BLADE W/OBD DESIGN TITUS 250;RETURN-BAR TYPE-DESIGN CENTER LINE OF STUD �j ALL MATERIALS AND INSTALLATION,DISPOSAL OF EXCESS MATERIALS(USEABLE FINISH MATERIALS SHALL BE 10.TRIM ACCESSORIES SHALL COMPLY WITH ASTM C-1047. TITUS 350;EXHAUST-METAL OR ALUMINUM-1/2"x 12"EGG CRATE DESIGN TITUS 50F. 6" NTL.STUDS a 24" O.C. O1+ LEFT IN THE TENANT SPACE AS DIRECTED BY PACTRUST),CLEANING AND ALL PREPARATION OF SUBSTRATE c. ALL SUPPLY REGISTERS TO HAVE MANUAL VOLUME DAMPERS LOCATED IN DUCT AT/OR NEAR CLOSEST SURFACES PRIOR TO INSTALLATION,AS WELL AS FINAL CLEAN UP. 11.USE GEORGIA PACIFIC DENSGLAS GOLD ON EXTERIOR FACE OF EXTERIOR WALLS AND COAT WITH STO FINISH WYE BRANCH. ONE LAYER 5/8" SHEETROCK BRAND 5. IT IS THE INTENT OF THESE CONTRACT DOCUMENTS TO MATCH AND MAINTAIN EXISTING BUILDING SYSTEM. FIRECODE CORE GYPSUM PANEL ON PROJECT #13560 d. CLEAN OR REPLACE ALL SUPPLY AND RETURN AIR GRILLS AND THEIR HOUSINGS AT PROJECT EACH SIDE OF METAL STUDS 24" O.C. STANDARDS FOR ALL EXISTING PRODUCTS AND SYSTEMS. UPON DISCOVERY OF A DISCREPANCY TO THIS WALL CONSTRUCTION EXECUTION COMPLETION. WITH TYPE S DRYWALL SCREWS 8' O.C. INTENSION,THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY. 1. FASTEN FRAMING MEMBERS TOGETHER BY WELDING OR BY USING SELF-DRILLING OR SELF-TAPPINGQ AT VERTICAL EDGES AND 12' O.C.TO 20.THERMOSTAT: ALL EXISTING MERCURY TYPE THERMOSTATS TO BE REPLACED. NEW THERMOSTATS TO BE > 6. FURNISH ALL NEW MATERIALS EXCEPT WHERE SPECIFICALLY NOTED OTHERWISE. SCREWS. WELDING SHALL CONFORM TO AWS D13 WELDING PROCEDURE. ELECTRODES AND SCREW HONEYWELL COMNERCIAL GRADE V/SIONPRO 8000 TOUCH SCRJM MODEI-T'88220U1003*WEREPOSSNLE TOP AND BOTTOM RUNNERS AND rl CONNECTIONS SHALL BE AS REQUIRED AND INDICATED IN THE DESIGN CALCULATIONS. DO NOT FIELD WELD APPROVED SUBSTITUTEOTAL-LI E SIGNATURECOMM A TA N NO 374.28W -7 DAY = INTERMEDIATE STUDS. STAGER ALL r l 7. COORDINATE THE WORK OF ALL TRADES. PROVIDE CARPET'WALK-0FF MATS"TO PROTECT EXISTING . V CARPETS. MATERIALS LIGHTER THAN 18 GAPROGRAMMABLE WITH LOCKOUT FUNCTION- U A H (MAY � VERTICAL AND HORIZONTAL JOINTS 24" 8. ALL ROOF PENETRATIONS FROM ABANDONED EQUIPMENT TO BE REMOVED. PATCH AND REPAIR ROOF Z. PROVIDE ACCURATELY ALIGNED RUNNERS AT TOP AND BOTTOM OF PARTITIONS. ANCHOR TRACKS AS REQUIRE CHANGING HEIGHT AT"REPLACEMENT'LOCATIONS). CONTRACTOR SHALL PROGRAM O.C. W MEMBRANE AS NEEDED. INDICATED IN THE DESIGN CALCULATIONS. BUTT WELD JOINTS IN TRACKS OR SPLICE WITH STUD INSERTS. THERMOSTATS AND BALANCE SYSTEM. FASTENERS SHALL BE AT LEAST 3 INCHES FROM THE EDGE OF CONCRETE SLABS. 21.THERMOSTAT LOCATIONS TO BE REVIEWED BY ARCHITECT PRIOR TO INSTALLATION. Emil 9. ALL ROOF WORK TO BE PERFORMED BY PACTRUST APPROVED ROOFING COMPANIES. APPROVED 3. CUT STUDS SQUARE AND SET WITH FIRM BEARING AGAINST WEBS OF TOP AND BOTTOM TRACKS. POSITION COMPANIES INCLUDE: STUDS VERTICALLY IN TRACKS AND SPACE AS INDICATED IN DESIGN. DO NOT SPLICE STUDS. PROVIDE AT 22•VAC TESTING. (I�� a. ANDERSON ROOFING, (503)294-0202 LEAST TWO FULL HEIGHT KING STUDS AT DOORS AND OTHER OPENINGS 2 FEET WIDE OR LARGER. PROVIDE a. CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES,COMPONENTS, b. PACIFIC ROOFING (503)640-3163 JACK STUDS OVER OPENINGS,AS NECESSARY,TO MAINTAIN INDICATED STUD SPACING. PROVIDE TRIPLE EQUIPMENT AND SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH STUDS AT CORNERS,POSITIONED TO RECEIVE INTERIOR AND EXTERIOR FINISHES. FASTEN STUDS AT TOP APPROVED PLANS AND SPECIFICATIONS. BATT INSUL. PER PLAN c. GRIFFITH ROOFING (503)643-1596 AND BOTTOM TRACKS BY WELDING OR SCREWING BOTH FLANGES TO THE TRACKS. b. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE IN 4" RUBBER BASE-TYP. 10.KEEP THE AREA OF WORK FREE OF GARBAGE AND DEBRIS ON A DAILY BASIS INCLUDING DOCK ACCESS 4. INSTALL ALL INTERIOR AND EXTERIOR GYPSUM BOARD PRODUCTS AND ACCESSORIES AS REQUIRED FOR ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. ATTACH BOTTOM TRACK TO FLOOR WITH AREAS AND COMMON AREA. FLOORS TO BE SWEPT OR VACUUMED DAILY. THE PROJECT. c. A COMPLETE COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND POWDER DRIVEN ANCHORS AT 12' 0.C, 11.PROVIDE ADEQUATE PROTECTION TO ALL EXISTING IMPROVEMENTS INCLUDING BUT NOT LIMITED TO 5. COMPLY WITH USG GYPSUM CONSTRUCTION HANDBOOK AND MANUFACTURER'S RECOMMENDATIONS. FILED WITH PACTRUST. COMMON CORRIDORS AND STAIRS,BUILDING ENTRANCES,SUITE ENTRANCES,ETC. THE CONTRACTOR WILL FINISH PER PLAN 6. FINISH QUALITY: 23.PROJECT CLOSE OUT DOCUMENTS REQUIRED: BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGES TO EXISTING IMPROVEMENTS DUE TO CONSTRUCTION O M ACTIVITIES. AREA PROCESS TRADE NOMENCLATURE a. AutoCAD FILE SHOWING AS-BUILT INFORMATION. 1 1/4' 12.PROVIDE TEMPORARY SANITARY FACILITIES. CONSTRUCTION WORKERS SHALL NOT USE BUILDING WAREHOUSE TAPE/FINISH COAT` TIGHT DOUBLE b. ELECTRONIC PDF FILE OF THE AutoCAD FILE ABOVE. 1 FULL HEIGHT WALL SECTION W/ INS. RESTROOM FACILITIES. OFFICE/OTHER AREAS TAPE/2 FINISH COATS•/ SMOOTH FINISH TAPED c. HARD COPY OF AutoCAD FILE ABOVE. 13.STORAGE AND STAGING OF CONSTRUCTION MATERIALS SHALL BE LIMITED TO AREAS AS DESIGNATED ATSAND AFTER TAPE/FINISH COAT(S) USG"FIRST COAT" d. OPERATIONS MANUALS FOR ALL EQUIPMENT,INCLUDING TSA-2 TATS. SCALE 1 n = F-10" p•N PRE-CONSTRUCTION MEETING. UNDER NO CIRCUMSTANCES SHALL BUILDING UTILITY AREAS OR ANY OTHER ` COMMON BUILDING AREA BE USED FOR STORAGE. 7. FINISH EXPOSED INTERIOR GYPSUM BOARD WALLS AND CEILINGS SMOOTH STRAIGHT READY FOR FINISH AS e. COLORED ZONE MAP WITH THERMOSTAT LOCATIONS INDICATED. a Q• 14.KEEP THE ROOF FREE OF DEBRIS(I.E.NAILS,SCREWS,BOTTLES,ETC.)AT ALL TIMES. SHOWN ON PLANS. 26 00 00 ELECTRICAL : DESIGN/BUILD BUILT UP ROOF ON WOOD 15.ALL DIMENSIONS ARE TO FACE OF GYPSUM BOARD UNLESS OTHERWISE NOTED. 09 9123 PAINTING GENERAL DECK a [� 16.CONFIRM SIZES OF ALL OPENINGS REQUIRED FOR THE INSTALLATION OF STRUCTURAL,MECHANICAL, INTERIOR: 1. ALL ELECTRICAL FEEDS TO OUTLET,SWITCHES,ETC.MUST BE VERTICAL DROPS FROM CEILINGS U.N.O. w N N EXCEPT FOR HORIZONTAL RUNS UNDER WINDOWS AND FIXTURES ON THE SAME STUD. EXISTING ROOF INSULATION ELECTRICAL AND PLUMBING WORK PRIOR TO FRAMING OR CUTTING FOR INSTALLATION. 1. WALLS: �D 17.LEAVE THE PROJECT CLEAN AND READY FOR OCCUPANCY. a. PRIME NEW DRYWALL WITH MILLER'S HIGH-BUILD"SUPER SEAL"PRIMER. 2. ALL ELECTRICAL FEEDS TO OUTLETS AND DATA BELOW WINDOW SILLS TO BE ROUTED THROUGH BUILDING `7\ O O 18.CLEAN ADJACENT EXTERIOR AREA,I.E.WALKS,EXTERIOR GLASS,ETC. b. NEW AND EXISTING DRYWALL TO BE FINISHED TO ACHIEVE UNIFORM COVERAGE WITH MILLER'S 620008 SHELL WALLS. DO NOT FEED FROM PERPENDICULAR INTERIOR PARTITIONS. 19.PROVIDE"AS-BUILT"DRAWINGS OF THE WORK AT THE CONCLUSION OF CONSTRUCTION."AS-BUILT" 4480 WITH A TIGHT ROLLER STIPPLE FINISH. RESTROOM FINISHES TO BE MILLER'S SIG LATEX ENAMEL. 3. PROVIDE LABELS AT EACH ELECTRICAL RECEPTACLE IDENTIFYING CORRESPONDING PANEL AND BREAKER. -- CONCRETE DRAWINGS MAY BE IN THE FORM OF TWO COPIES OF CONSTRUCTION DOCUMENTS MARKED-UP WITH RED 2. DOORS AND FRAMES: 3. PROVIDE UPDATED SCHEDULE AT PANEL TO IDENTIFY CIRCUIT BREAKERS. Q PEN.DELIVER RECORD DRAWINGS TO THE ARCHITECT. COMPLETE OPERATION AND MAINTENANCE MANUALS SHALL BE PROVIDED FOR ALL MECHANICAL,ELECTRICAL AND PLUMBING EQUIPMENT.PACTRUST MAY HOLD a. NEW HOLLOW METAL-PRIME,SAND,AND FINISH WITH TWO COATS OF SEMI-GLOSS OIL. 4. ELECTRICAL CONTRACTOR TO PROVIDE EMERGENCY LIGHTING IN PATH SHOWN ON PLAN EQUAL TO 1-FOOT CONTRACTOR'S FINAL PAYMENT UNTIL"AS-BUILT'DRAWINGS AND O 8 M MANUALS HAVE BEEN RECEIVED b. EXISTING HOLLOW METAL-SAND,FILL IMPERFECTIONS WITH RONDO,SAND AND PRIME PATCHES WITH CANDLE. AND APPROVED. ALKYD PRIMER,AND FINISH WITH SEMI-GLOSS OIL ENAMEL. 5. EXIT LIGHTS:RUUD LIGHTING"PLASTIC LED EXIT SIGN"MODEL EXPBURWH RED LETTERS,WHITE HOUSING, a 20.IT IS THE INTENT OF THE CONTRACT DOCUMENTS THAT THE CONTRACTOR PROVIDE A COMPLETE, c. NEW WOOD-PRIME WITH ALKYD OIL UNDER-COATER,SAND,FILL ALL FASTENING HOLES WITH WITH BATTERY BACKUP- INSTALL R-13 BATT INSULATION FS 25 FUNCTIONING PROJECT INCLUDING ALL GENERAL,MECHANICAL AND ELECTRICAL CONSTRUCTION REQUIRED PAINTER'S PUTTY,CAULK ALL CRACKS IN CASINGS AND BETWEEN JAMBS AND WALLS USING DAP LATEX 6. WHERE NEEDED,CONTRACTOR TO FURNISH AND INSTALL NEW DRY TYPE TRANSFORMERS TO PROVIDE TO CONCRETE WALLS WITH STICK CLIPS TO FULFILL THAT INTENT. ALL ITEMS REQUIRED SHALL BE FURNISHED AND INSTALLED,REGARDLESS OF CAULK,AND FINISH WITH SATIN OIL ENAMEL. 208V/120V POWER FROM THE 4BOV1277V SYSTEM. SIZE TO BE BIDDER DESIGN. (OR EXTEND STUDS) - COVER WITH a. WHETHER OR NOT SHOWN ON THE DRAWINGS. d. EXISTING WOOD-PREP,REPAIR IMPERFECTIONS,PRIME AS REQUIRED,AND REPAINT WITH SATIN OIL a. TRANSFORMERS TO BE ENERGY STAR LABELED. WHITE METALIZED POLYPROPYLENE 21.ITEMS OR WORK NOT TO BE FURNISHED OR ACCOMPLISHED BY CONTRACTOR ARE NOTED"N.I.0". ENAMEL. IF FINISH IS NOT PAINTED,TOUCH UP STAIN,SEAL AS REQUIRED,AND RE-VARNISH WITH SATIN b. CASE TO BE TOTALLY ENCLOSED WITH LOUVERS TO PREVENT FOREIGN OBJECTS INTO THE INTERIOR. WITH FIBERGLASS SCRIM 22."ALIGN"AS USED IN THESE DOCUMENTS,MEANS TO ALIGN THE FINISHED FACES OF ELEMENTS IN THE SAME VARNISH. PLANE,EITHER IMMEDIATELY ADJACENT TO ONE ANOTHER OR ACROSS AN OPENING. 3. GENERAL NOTES: C. ENCLOSED AND VENTILATED,AIR COOLED TYPE,CLASS H INSULATION,DESIGNED FOR 115 DEGREES C a TEMPERATURE RISE ABOVE 40 DEGREES C AMBIENT TEMPERATURE AT FULL LOAD CONTINUOUS 23.DO NOT DISASSEMBLE SETS OF CONSTRUCTION DRAWINGS.DRAWINGS ARE INTERRELATED. a. KEEP ALL HARDWARE,HINGES,AND DOOR KNOBS CLEAN OF ALL PAINT SPLATTERS,DRIPS,OR ROLLER OPERATION. EQUIP WITH 2-1/2 PERCENT ANFC TAPS AND FOUR 2-1/2 PERCENT BNFC TAPS. MAXIMUM ON 24.SUBMIT SAMPLES OR DRAW DOWNS FOR ALL FINISHES REQUESTED TO THE ARCHITECT OF RECORD WITHIN SPRAY. SOUND LEVEL SHALL BE NEMA STANDARD WITH ISOLATION DAMPERS BETWEEN THE CORE AND COIL FURRING TO 10' AFF,WITH INSULATION V-4 N TWO WEEKS OF PROJECT AWARD.PRODUCTS INSTALLED WITHOUT APPROVED SAMPLES ARE SUBJECT TO b. ALL SURFACES TO BE SANDED BETWEEN COATS,PRIOR TO INSTALLATION OF NEXT COAT. ASSEMBLY AND CASE. AND 5/8'GYP BOARD. m' ala. O REPLACEMENT AT CONTRACTOR COST. c. DURING PROGRESS OF WORK,KEEP JOB SITE CLEAN OF ALL PAINT MATERIALS,RUBBISH,CANS,AND 9 TELECOMMUNICATION SYSTEM BY FUTURE TENANT. p 25.SUBMIT COMPLETE SHOP DRAWINGS FOR MILLWORK,SPECIAL SYSTEMS,MECHANICAL,ELECTRICAL AND RAGS AT THE END OF EACH DAY. 10.LIGHTING ENERGY MANAGEMENT IS REQUIRED IN ALL BUILDINGS. ALUMINUM WINDOW SYSTEM FLASHING ch PLUMBING SYSTEMS(INCLUDING FIRE PROTECTION SYSTEMS). SUBMIT A MINIMUM OF TWO COPIES OF ALL IL SHOP DRAWINGS FOR REVIEW AND APPROVAL TO THE ARCHITECT OF RECORD.ARCHITECT WILL RETAIN ONE d. UPON COMPLETION OF WORK,CLEAN ANY PAINT SPLATTER BY USING PROPER METHODS OF WASHING 11.00CUPANCY CONTROL DEVICES SHALL BE LEVITON OR WATT STOP. O AND SCRAPING,USING CARE NOT TO SCRATCH OR DAMAGE FINISHED SURFACES. CAULK AT JAM COPY AND ONE COPY WILL BE RETURNED TO THE CONTRACTOR. 12.TEST ALL LIGHTING CONTROL SYSTEMS TO ENSURE THAT CONTROL DEVICES,COMPONENTS,EQUIPMENT 26.THE DESIGN OF FIRE PROTECTION SYSTEMS IS THE RESPONSIBILITY OF THE FIRE PROTECTION SYSTEMS e. PROTECT WORK OF OTHER TRADES. AND SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND CONTRACTOR.ALL FIRE PROTECTION SYSTEMS SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER f. PROVIDE"WET PAINT"SIGNS AS REQUIRED TO PROTECT NEWLY PAINTED FINISHES. SPECIFICATIONS. SEQUENCES OF OPERATION SHALL FUNCTIONALLY TESTED TO ENSURE TRAY OPERATE 5/8' GYP BRD FLASHING LICENSED BY THE APPROPRIATE JURISDICTION FOR THE DESIGN OFTHIS TYPE OF SYSTEM. COORDINATE IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATK>rIS. INTERFACE WITH EXISTING BUILDING SYSTEMS AND WITH ARCHITECT. ALL SPRINKLER HEADS SHALL BE 10 00 00 SPECIALTIES 13.REQUIRED IN DIVISION 15,PROVIDE MONITORING OF HVAC EQUIPMENT PER CODE. --STO PANEL L R-19 BATT INSULATION CENTERED IN CEILING TILE(OR 2 x 2 MODULE OF A SECOND LOOK II TYPE OF CEILING TILE WHERE 10 4416 FIRE EXTINGUISHERS 14.REMOVE ALL UNUSED DATA AND POWER BOXES AND INFILL WITH GYP BOARD. EXCEPTION-UNUSED DATA APPLICABLE). LOCATION OF THOSE IN GYPSUM BOARD CEILINGS SHALL BE PRE-/APPROVED IN WRITING BY 1. FIRE EXTINGUISHER 2A10 BC (WALL MOUNTED OR IN SEMI RECESSED CABINET AS INDICATED ON PLAN) BOXES UNDER WINDOW SILLS TO REMAIN. ALL BLANK COVER PLATES TO BE BUILDING STANDARD FINISH. FLASHING O A THE ARCHITECT PRIOR TO INSTALLATION. 2. FIRE EXTINGUISHER CABINET: JL INDUSTRIES ACADEMY SERIES MODEL#C1027V10. 15.REMOVE ALL UNUSED LOW VOLTAGE WIRING(TELEPHONE AND DATA)FROM THE RECEPTACLE TOTHE FINISH FLOOR 27.COORDINATE ALL CONSTRUCTION SEQUENCING WITH PACTRUST AND SCHEDULE ALL SERVICE DISTRIBUTION BOARD.LEAVE PULL STRINGS FROM THE BOX TO THE SPACE ABOVE THE CEILING. A SECTION INTERRUPTIONS OUTSIDE NORMAL BUSINESS HOURS TO MINIMIZE INCONVENIENCE TO CURRENT TENANTS. 12 00 00 FURNISHINGS OF THE EXISTTNG LOW VOLTAGE WIRE MAY BE LEFT IN LIEU OF A PULL.STRING GENERAL 1. PROVIDE BUILDING STANDARD BLINDS AT ALL NEW EXTERIOR GLASS. UGHTING 2 EXTERIOR WALL FURRING DETAIL 1. ALL ROOF PENETRATIONS FOR ELECTRICAL,LOW VOLTAGE,GAS PIPING,ETC.SHALL BE SLEEVED THROUGH 23 00 00 HVAC : DESIGN I BUILD 1. (2)TUBE T5HO LIGHTING AT 15'A.F.F.FOR 40 FC AT 30"A.F.F. A LEAD ROOF JACK,CLAMPED WITH A STAINLESS STEEL CLAMP AND SEALED WITH VULKEM 921 A'2 SCALE 1"= 1'-0" POLYURETHANE SEALANT. SILICONE SEALANT NOT PERMITTED. GAS METER 07 00 00 THERMAL&MOISTURE PROTECTION 1. CONTRACTOR TO VERIFY GAS METER AND TAG METER WITH THE TENANTS ADDRESS OR SUITE NUMBER. I1 1. REPLACE ALL MISSING AND DAMAGED ROOF AND WALL INSULATION ABOVE THE CEILING GRID. METER IDENTIFICATION NUMBER AND TENANT ADDRESS INFORMATION SHALL BE GIVEN TO PACTRUST PRIOR TO TENANTS MOVE-IN. 2. PROVIDE NEW ROOF INSULATION TO MATCH EXISTING AT ABANDONED MECHANICAL UNITS. HVAC-BID PROCEDURE 3. AT ALL UN-USED EXISTING ROOF PENETRATIONS,REMOVE EQUIPMENT AND REPAIR ROOF SYSTEM. 1. FORBIDDING PURPOSES,THE HVAC CONTRACTOR WILL ASSUME THAT EXISTING HVAC EQUIPMENT IS IN 0810 00 DOORS AND WINDOWS PROPER WORKING ORDER. 1. RE-USE EXISTING DOORS AND FRAMES WHERE POSSIBLE 2. INVENTORY EXISTING H.V.A.C.ROOFTOP UNITS AND SUBMITTO ARCHITECTA CONDITIONS REPORT OF EACH 2. APPROVED DOOR,FRAME,AND HARDWARE SUPPLIERS INCLUDE: UNIT 3. LIST TONNAGE OF EACH UNIT. a. BAXTER AND FLAMING. (503)225-0486 HVAC-DESIGN PROCEDURE b. D 8 D DOOR (503)205-5533 TYPICAL STUD c. BENSON INDUSTRIES (503)907-2200 USE EXISTING AND/OR NEW EQUIPMENT TO DESIGN MECHANICAL H.V.A.C.SYSTEM PER DESIGN STANDARDS LISTED BELOW. d. GRANT SUPPLY (360)887-0647 PRIOR TO AWARD OF CONSTRUCTION CONTRACT,H.V.A.C.CONTRACTOR SHALL SUBMIT TO ARCHITECT FOR 3. DOOR AND RELITE FRAMES SHALL BE TIMELY,OR APPROVED. SUBMITTAL REQUIRED PRIOR TO ORDERING REVIEW AND APPROVAL A FULL DESIGN SCHEMATIC FOR THE TENANT SPACE INCLUDING BOTH MATERIAL.NEW FRAMES TO BE FACTORY FINISH CUSTOM COLOR. NEW/RENOVATED WORK AND SYSTEMS UNTOUCHED BY THE TENANT IMPROVEMENT AS APPLICABLE. 4. EXTERIOR DOORS AND FRAMES TO BE HOLLOW METAL. FRAMES OF ONE-PIECE WELDED CONSTRUCTION, INCLUDE THE FOLLOWING: 14-GA.GALV.SHEET STEEL. DOORS,SDI-100,GRADE II,SEAMLESS EDGES,16GA.GALV.SHEET STEEL. a. DUCTING AND SIZES TYPICAL TRACK FABRICATE DOORS AND FRAMES WITH HARDWARE REINFORCING WELDED IN PLACE. b. SUPPLY AND RETURN LOCATIONS AND CFM 5. FIELD VERIFY EXISTING DOOR,FRAME AND HARDWARE FINISH PRIOR TO ORDERING. ALL NEW DOORS, c. ROOF EQUIPMENT,SIZES AND LOCATIONS INSTALL STUDS WITH SAME FRAMES AND HARDWARE TO MATCH EXISTING BUILDING STANDARDS. DIMENSION (10' MIN.)FOR 6. ALL INTERIOR DOORS SHALL BE SOLID CORE WOOD UNLESS NOTED OTHERWISE. d. UNITS REQUIRING DUCTED SMOKE DETECTION BRIDGING ALIGNMENT e. THERMOSTAT LOCATIONS AND ZONENNIT ASSOCIATED THEREWITH 7. DOOR HARDWARE SHALL BE SCHLAGE AL SATURN OR D RHODES SERIES U.N.O. f. ANY SUPPLEMENTAL EXHAUST FANS OR SPECIAL SYSTEMS 8. ALL DOOR HARDWARE SHALL BE INSTALLED WITH A 5"BACKSET. 9. DOOR FINISH SUBMITTAL:CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR DOOR FRAMES,DOOR 9. ZONE DIAGRAM HARDWARE AND DOORS AS WELL AS A CONTROL SAMPLE OFTHE FINISHED DOOR SKIN W/STAIN AND FINISH HVAC DESIGN STANDARDS APPLIED(IF NEW DOORS ARE BEING PROVIDED). BEFORE FINISHING OF DOORS IS COMMENCED ARCHITECT THE FOLLOWING ARE MINIMUM DESIGN STANDARDS: POWDER DRIVEN a N SHALL APPROVE CONTROL SAMPLE. FINISHED PRODUCT IS SUBJECT TO REJECTION BY ARCHITECT IF THIS IN PROCESS IS NOT FULLY ADHERED TO AND FIELD PRODUCT DOES NOT MATCH THE APPROVED CONTROL 1. 350 SQUARE FOOT PER TON. ANCHORS AT 12 O.C. cn SAMPLE. 2. ADDRESS LOADS BY SPECIFIC LOCATION AND USE AS WELL AS CRITERIA PROVIDED TO PACTRUST BY GW' as i a as 10.ALL INTERIOR GLAZING SHALL BE TEMPERED. TENANT PRIOR TO CONSTRUCTION: (1) 010-I6 SCREW Q 11.DEAD BOLT LOCKS AT NEW EXTERIOR DOORS TO BE INSTALLED WITH A SCHLAGE MORTISE DOUBLE a. EXTERIOR EXPOSURE AREAS PER STUD FLANGEN CYLINDER 20-013C "C'KEYWAY;SOLID BRASS;WITH ADAMS-RITE CAM AND COMPRESSION RING 1 1/8"LENGTH b. INTERIOR AREAS,SIZE AND USE L� WITH HARDENED CYLINDER GUARD RING KEEOEX K-24. FINISH TO MATCH BUILDING STANDARD. O z Fir V 12.PATCH AND REPAIR ALL HOLES OR DAMAGE TO EXISTING STORE FRONT WINDOWS AND DOORS.TOUCH UP c. CONFERENCE/TRAINING ROOMS FINISH FOR AS NEW LOOK. d. COMPUTER/SERVER AND TELEPHONE ROOMS TO HAVE PROVISION FOR LOW AMBIENT OPERATION AND 24-HOUR USE. V cn 0900 00 FINISHES 3 WALL BASE DETAIL o i 3. SYSTEM DESIGN CRITERIA-SIZE ZONES FOR 3-5 TON UNITS BASED ON USE 8 EXPOSURE CRITERIA. GENERAL PACKAGED OR SPLIT SYSTEM EQUIPMENT GREATER THAN 5 TONS SHALL BE SPLIT INTO MULTIPLE ZONES. 1. CLEAN,SEAL AND WAX ALL RESILIENT FLOORS PER MANUFACTURERS SPECIFICATIONS. VAV OR WATER SOURCE HEAT PUMP SYSTEMS GREATER THAN 3TONS SHALL BE SPLIT INTO MULTIPLE A-2 SCALE 3" = 1t-O" ZONES. REVISION E�/�` T �T 2. SUBMIT SAMPLES OR DRAW DOWNS FOR THE FOLLOWING: 4. ALL ENCLOSED ROOMS OR OFFICES TO HAVE DUCTED SUPPLY 8 RETURN GRILLES. R1SIO1�1 a. FLOOR COVERINGS AND BASE 5. VACANT SPACE SHALL HAVE DEDICATED GAS SERVICE FOR FUTURE BUILD-OUT OR FREEZE PROTECTION. b. PLASTIC LAMINATES 6. UNITS: LENNOX,TRANE,YORK OR CARRIER-7 1/2-TON MAXIMUM UNIT SIZE. ANY UNIT IN EXCESS OF 712 C. ALL NATURAL WOOD(INCLUDING DOORS AND CASEWORK) TONS SHALL HAVE SPECIAL APPROVAL BY BUILDING OWNER. 1 d. PAINT 7. HVAC UNITS WITH EQUAL TO OR GREATER THAN 5-TONS TO HAVE DUCT SMOKE DETECTORS AND BE 2. e. TILE,MARBLE,GRANITE,STONE,AND GROUT CONNECTED TO A MONITORING STATION WITHIN THE BUILDING. f. TOILET PARTITIONS 8. ROOF TOP UNITS SHALL BE PLACED 24'MINIMUM FROM ROOF EDGE TO CENTER OF UNIT. MULTIPLE UNITS 3• SHALL BE PLACED SYMMETRICALLY IN A LINE BASED ON STRUCTURAL CALCULATIONS BY ENGINEER. g. HARDWARE 9. CURBS: 14"CURBS. ASSEMBLED AND LEVELED TO ROOF,ANCHORED TO STRUCTURAL MEMBERS BELOW 4. 3. EXTEND FINISH FLOORING UNDER ALL NEW CASEWORK. ROOFING. 09 2100 GYPSUM BOARD a. PROFESSIONALLY ROOF IN ALL CURBS AND PENETRATIONS BY PACTRUST APPROVED ROOF 5• GENERAL CONTRACTOR. SEE DIVISION 1 GENERAL NOTES THIS PAGE. 1. ALL GYPSUM BOARD TO BE A MINIMUM OF 5/8"THICK VERTICALLY ATTACHED TO METAL STUDS 24"O.C.WITH b. UNIT MUST BE LEVEL,SEALED WITH NO AIR LEAKS AND COUNTER FLASHED. 6' 1"TYPE S-12 SCREWS 12"O.C.UNLESS OTHERWISE NOTED. c. CONDENSATE MUST BE TRAPPED AT UNIT. 2. ALL OFFICE GYPSUM BOARD TO RECEIVE ONE TAPE COAT AND TWO FINISH COATS WITH SANDING BETWEEN 10.SEISMICALLY ATTACH UNIT TO CURB IN CODE-APPROVED METHOD. FINISH COATS. APPLY USG SHEETROCK BRAND FIRST COAT. PAINT AS INDICATED. 11.ALL GAS PIPING SHALL BE STANDARD BLACK STEEL PIPE W/SUPPORTS PER CODE. PIPING SHALL BE RUN 3. ALL OTHER GYPSUM BOARD TO RECEIVE ONE TAPE COAT AND ONE FINISH COAT WITH SANDING AFTER FINISH INSIDE OF BUILDING W/LEAD FLASHINGS AT ROOF PENETRATIONS. LEAD ROOF JACKS TO BE SEALED AND COAT. PAINT AS INDICATED. CLAMPED(S.S.WORM GEAR). 4. ALL ONE HOUR RATED WALLS(WHERE APPLICABLE): ONE LAYER 5/8"TYPE X GYPSUM WALLBOARD,EITHER 12.ALL EXISTING AND NEW GAS PIPING EXPOSED TO THE EXTERIOR TO BE PROTECTED FROM RUST AND AT RIGHT ANGLES OR PARALLEL TO FRAMING ON EACH SIDE OF METAL STUDS SPACED AT 24"O.C. FASTEN CORROSION WITH OIL BASED PAINT(COLOR GREY). WITH 1"TYPE S DRYWALL SCREWS 8"O.C.TO VERTICAL EDGES AND 12"O.C.TO TOP AND BOTTOM RUNNERS 13.LOW VOLTAGE IN SEALTITE CONDUIT FROM BELOW ROOF LINE DIRECT TO UNIT. DO NOT EXCEED BEND AND INTERMEDIATE STUDS. STAGGER ALL VERTICAL AND HORIZONTAL JOINTS 24"O.C.(OR ONE STUD RADIUS MANUFACTURER'S GUIDELINE. SPACING),EACH SIDE AND OPPOSITE SIDES. DATE 9/30/13 5. IN FINISHED SPACES FURR-OUT BUILDING COLUMNS AND EXTERIOR WALLS WITH 5/8"GYPSUM BOARD OVER 14.ECONOMIZER TO MEET CODE AND AS FOLLOWS: METAL STUDS. a. 6 TONS AND ABOVE MUST HAVE ECONOMIZER. PERMIT SET 6. PROVIDE ACOUSTIC GASKETS WHERE WALL INTERSECTS MULLIONS OR GLAZING. b. BAROMETRIC RELIEF ON 5-712 TON UNITS. 7. AT ALL EXISTING WALLS,REMOVE ALL NAILS,SCREWS,FASTENERS,ETC.LEFT BY PREVIOUS TENANT AND c. 8 TONS AND ABOVE MUST HAVE POWER EXHAUST. PATCH HOLES READY FOR PAINT. d. 1 12 THRU 4-TON OSA INTAKE WITH DAMPER. 8. UPON REMOVAL OF WALL BASE,REMOVE RESIDUAL ADHESIVE AND PREP WALL TO PAINT READY CONDITION. 15.ALL UNITS TO MEET OR EXCEED CURRENT ENERGY EFFICIENCY CODE REQUIREMENTS. WALL CONSTRUCTION MATERIALS 16.DROP CANS TO FULL SIZE OF UNIT CURB OPENING. MINIMUM 26 GAUGE WITH SUPPLY AIR. EDGES OF SUPPLY 1. PROVIDE STUDS,TRACKS,BRACING,FASTENING AND OTHER ACCESSORIES NECESSARY FOR COMPLETE AIR SEALED. DROP CANS TO BE EXTENDED TO WITHIN Z OF CEILING. INSTALLATION. 17.DISTRIBUTION DUCTWORK: 2. FRAMING MEMBERS SHALL HAVE THE STRUCTURAL PROPERTIES INDICATED WHERE PHYSICAL STRUCTURAL a. SPIRAL ONLY IF EXPOSED. PROPERTIES ARE NOT INDICATED,THEY SHALL BE AS NECESSARY TO WITHSTAND ALL IMPOSED LIVE LOADS. DESIGN FRAMING IN ACCORDANCE WITH AISI SG-673. b. 26 GAUGE OR TO SMACNA STANDARDS IF PIPE IS CONCEALED ABOVE DROP OR HARD CEILING. 3. COLD-FORMED FRAMING SHALL BE GALVANIZED METAL CONFORMING TO ASTM A44EJA 446 M GRADE A(33000 c. WRAP CONCEALED SUPPLY DUCTWORK IN NON-CONDITIONED AND SEMI-CONDITIONED SPACE WITH MINIMUM R4.2 INSULATION WITH FSK BARRIER. r---------- CIRC. #3082 1Z 11. MARTIN W. HANSON LJ --- CLA KAM S, OREGON HCWRR MEF IT ------ - tAL�j 1141 wom Eiiii afil 0 IL----------il 'COL OF 0* Cl PROJECT #13560 i L-------i Ila 0 cl STOR ENT 116 3 FLOOR PLAN NOTES: m O DEMO WALL AND DOOR CEILING PLAN NOTES: 7 (J) INSTALL HVAC WITH SPIRAL DUCTING DISTRIBUTION (4) (4) CONSTRUCT NEW FULL HEIGHT WALL WITH INSULATION 104 INSTALL(2)TUBE T5HO LIGHTING AT 15'A.F.F. FOR 40 FC AT 30"A.F.F. (4) INSTALL GYP BOARD FURRING WITH INSULATION TO 10'A.F.F. =O r------- ------- ------- --------r------- --------r--------r--------T---------r-------i AND STICK PEN INSULATION ABOVE TO STRUCTURE. (4) PRVIDE EMERGANCY EGRESS LIGHTING IN PATH SHOWN. PATCH AND PAINT EXISTING WALLS NEW EXIT SIGN REMOVE OVERHEAD DOOR IN INFILL OPENING. INSTALL --------------------------------------- WINDOWS IN TOP 24"OF OPENING. 4 ch N o in REMOVE EXTERIOR STAIRS en It (J) INSTALL RELOCATED DOUBLE IMPACT DOORS WITH BOLT PEN LOCKS AND CLOSERS INSTALL NEW DOUBLE IMPACT DOORS WITH BOLT PEN LOCKS M p4 w AND CLOSERS TO MATCH EXISTING. Re GRIND AND RE-SEAL CONCRETE FLOOR. WAR84OUSE F120 10 PROVIDE POWER THROUGH WALL FOR TENANT FURNITURE 10 11 PROVIDE PROVIDE POWERIDATA DROP FOR TENANT FURNITURE EMM4 OPEN OFFICE O oIL OF122] Fm L § ------------------------ lk�------ z. L--------L--------L--------L------- cA i roll -------- -------- -------- --------T--------I Ea 15-0 15'-0Ea IV N ------------- -------------------------- I L--------I L--------1 L--------I L--------I L-------i I CONSTRUCTION LEGEND ------------ EXISTING TO REMAIN fl ---------------- --------- -------- EXISTING TO BE REMOVED NEW WALL TO ROOF STRUCTURE -------------------------------- con 1( 1�) 1 i ELECTRICAL LEGEND u I Z DUPLEX RECEPTACLE ------- ------- ------- ------- ------- C) L FOURPLEX RECEPTACLE k",0_1 u OD=,Q DEDICATED OUTLET EXISTING ELECTRICAL TO REMAIN VISION 'D4 FLOOR MONUMENT W/SERVICES SHOWN ,wl, SPECIAL OUTLET 1 TEL/DATA MUD RING WITH PULL STRING 2. ui ELECTRICAL PANEL 3. POWER J-BOX 4. 5,684 SF OFFICE EXPANSION 4) FLOOR MONUMENT W/POWER AND DATA 5. FER FIRE EXTINGUISHER IN RECESSED CAB. 6. FEs FIRE EXTINGUISHER-SURFACE MOUNTED THERMOSTAT rl \PARTIAL FLOOR PLAN riPARTIAL REFLECTED CEILING PLAN CEILING LEGEND SCALE 1/8"= 1'-0" SCALE 1/8"= F-0" INDICATES EGRESS LIGHTING FEE=j (2)TUBE T5HO LIGHTING AT 157 A.F.F.FOR 40 FC AT 30"A.F.F. DATE 9/30/13� $ STANDARD SWITCH PERMIT SET (1) OCCUPANCY SWITCH CEILING OCCUPANCY SENSOR EXIT SIGN(LED RED) UIQ HORN/STROBE FIRE ALARM(WALL MOUNT)(SINGLE-S-INDICATES STROBE ONLY) 4X( 0 HORN/STROBE FIRE ALARM(CEILING MOUNT)(SINGLE W INDICATES STROBE ONLY) Affil WO NC LIGHTING QUAL INDICATES COMMON PATH OF TRAVEL REQUIREING EMERGENCY E TO FOOT CANDLE. 31