Loading...
Plans (3) BUP2013 00010 01 00 00 GENERAL DATA 7. UPON REMOVAL OF WALL BASE,REMOVE RESIDUAL ADHESIVE AND PREP WALL TO PAINT READY CONDITION. 5. POINT OF DEMAND WATER HEATER-BOSCH POWER STREAM PRO-MODEL RP2P 277V/30A. ADJUST WATER b. ELECTRONIC PDF FILE OF THE AIAOCAD FILE ABOVE. FLOW SETTING TO PROVIDE A HEATING RANGE OF 105 TO 120 DEGREES. CONTACT MESHER SUPPLY FOR TENANT IMPROVEMENT for GENERAL REQUIREMENTS WALL CONSTRUCTION MATERIALS AVAILABILITY,(503)236.4148. c. WARD COPY OF AutoCAD FILE ABOVE. 1. ALL CONSTRUCTION WORK SHALL BE DONE IN COMPLIANCE WITH THE LATEST EDITION OF THE OREGON t. PROVIDE STUDS,TRACKS,BRACING,FASTENING AND OTHER ACCESSORIES NECESSARY FOR COMPLETE d. OPERATIONS MANUALS FOR ALL EQUIPMENT,INCLUDING T-STATS. . STRUCTURAL SPECIALTY CODE,AND ALL OTHER STATE OR LOCAL CODE REQUIREMENTS THAT APPLY. INSTALLATION. 6. FLOOR DRAINS TO BE INSTALLED WITH PRIMER VALVE WITH ISOLATION VALVE. NO PROVIDE PH N.OPRIMERS. 3082 ik."DRAINS TO BE PRIMED FROM TOILET FIXTURES UNLESS APPROVED BY OWNER. PROVIDE A MIN.OF 12" e. COLORED ZONE MAP WiTH THERMOSTAT LOCATINJS INDICATED. # , 2. VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON DRAWINGS AND AT THE EXISTING BUILDING AND 2. FRAMING MEMBERS SHALL HAVE THE STRUCTURAL PROPERTIES INDICATED WHERE PHYSICAL STRUCTURAL ACCESS DOOR. 26 00 p0 ELECTRICAL :DESIGN/BUILD MARTIN W. HANSON NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO STARTING THE WORK PROPERTIES ARE NOT INDICATED,THEY SHALL BE AS NECESSARY TO WITHSTAND ALL IMPOSED LIVE LOADS. DESIGN FRAMING IN ACCORDANCE WITH AISI SG 673.L pLUNBPLUMB00 ING_REST ROOM FIXTURES(SINGLE OCCUPANCY) GENERAL T N TIONA3. CONTRACTOR AND ALL SUBCONTRACTORS SHALL PERFORM DUE DILIGENCE INSPECTION OF ALL EXISTING - .AR Ga IN ER CONDITIONS PRIOR TO SUBMITTAL OF A PROPOSAL.SUBMITTALOFA PROPOSAL SHALL BE CONSIDERED 3. COLD-FORMED FRAMING SHALL BE GALVANIZED METAL CONFORMING TOASTM A446/A 446 M GRADE A(33000 1. REUSE EXISTING FIXTURES WHERE POSSIBLE 1. ALL ELECTRICAL FEEDS TO OUTLET,SWITCHES,ETC.MUST BE VERTICAL DROPS FROM CEILINGS U.N.O. r/�CLA KAM S, OREGON,y CONFIRMATION THAT SUCH INSPECTION HAS BEEN MADE,AND NO FURTHER COMPENSATION SHALL BE DUE PSI)G60. 2. TOILET FLOOR MOUNT TANK TYPE TOTO CST744EL(SL AT ADA STALL)OR KOHLER CIMARRON K3496 EXCEPT FOR HORIZONTAL RUNS UNDER WINDOWS AND FIXTURES ON THE SAME STUD. `' O THE CONTRACTOR FOR CLAIMS ARISING AS A RESULT OF FAILURE TO PERFORM SUCH INSPECTION. 4. PROVIDE THE LISTED GYPSUM BOARD PRODUCTS BY U.S.GYPSUM,GEORGIA PACIFIC,NATIONAL GYPSUM OR 3. AT BACK TO BACK TANK TYPE TOILET INSTALLATIONS US 3"VENT PIPE THROUGH ROOF. 2. ALL ELECTRICAL FEEDS TO OUTLETS AND DATA BELOW WINDOW SILLS TO BE ROUTED THROUGH BUILDING CORPO)UTION EXAM NED TWINE SITE AND INCLUDED IN TWERP OPOSAL ALL W�DRK NEGE SARY O COMPLf£TE THE WORK AN APPROVED EQUAL. 4. TOILET SEAT: BEMIS 1955SSC OR OLSONITE 10SSCT SHELL WALLS. DO NOT FEED FROM PERPENDICULAR INTERIOR PARTITIONS. ,ff� 5. STANDARD GYPSUM BOARD SHALL BE TYPE W,5/8"THICK WITH TAPERED EDGES CONFORMING TO ASTM 3. PROVIDE LABELS AT EACH ELECTRICAL RECEPTACLE IDENTIFYING CORRESPONDING PANEL AND BREAKER. v � t - DESCRIBED OR REASONABLY IMPLIED IN THESE DOCUMENTS. THIS INCLUDES BUT MAY NOT BE LIMITED TO G-36. 5. WALL HUNG LAVATORY TOTO LT307.4 ALL MATERIALS AND INSTALLATION,DISPOSAL OF EXCESS MATERIALS(USEABLE FINISH MATERIALS SHALL BE3. PROVIDE UPDATED SCHEDULE AT PANEL TO IDENTIFY CIRCUIT BREAKERS. LEFT IN THE TENANT SPACE AS DIRECTED BY PACTRUST),CLEANING AND ALL PREPARATION OF SUBSTRATE 6. WATER RESISTANT GYPSUM BOARD SHALL BE 5/8'THICK WITH TAPERED EDGES. CONFORMING TO ASTM 6. LAVATORY FAUCET-DELTA 501 DST PROD ECT NARRATIVE SURFACES PRIOR TO INSTALLATION,AS w£LL AS FINAL CLEANUP.UP. C s30. 7. SEALANT OF PLUMBING FIXTURES: 4 IDENTIFICATION NUMBER AND TENANTDDREVERIFY ELECTRICAL METER AND TAG METER SS INFORMATION SHAH THE TENANTS DDRESS OR SUITE NUMBER. METER LLL BE GIVEN O PACTRUST PRIOR TO PROJECT#12680 5. IT IS THE INTENT OF THESE CONTRACT DOCUMENTS TO MATCH AND MAINTAIN EXISTING BUILDING 7. AT TOILET ROOMS USE 518"USG FIBERROCK BRAND AQUATOUGH INTERIOR PANEL FROM FLOOR TO 48"A.F.F. a. ALL SEALANT SHALL MATCH GROUT COLOR AT TILE SURFACES. TENANTS MOVE-IN. PROJECT CONSISTS OF REMODEL WORK TO 12,804 SF OF EXISTING OFFICE AND STANDARDS FOR ALL EXISTING PRODUCTS AND SYSTEMS. UPON DISCOVERY OF A DISCREPANCY TO THIS ON WALLS BEHIND OR ADJACENT TO PLUMBING FIXTURES. NO SUBSTITUTES.(EXCEPTION:EXCEPTION AT b. SUBMIT SEALANT COLOR PRIOR TO INSTALLATION FOR ARCHITECT APPROVAL FOR ALL OTHER 5. ELECTRICAL CONTRACTOR TO PROVIDE EMERGENCY LIGHTING IN PATH SHOWN ON PLAN EQUAL TO 1-FOOT WAREHOUSE SPACE. WORK SHALL INCLUDE BUT NOT BE LIMITED TO FINISHES,LIGHTING INTENSION,THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY. LOCATIONS TO RECIEVE PLASTIC LAMINATE OR TiLE WAINSCOT.) APPLICATIONS. CANDLE. T AND PAINTING. ALL WORK TO MEET ADA REQUIREMENTS. 6. FURNISH ALL NEW MATERIALS EXCEPT WHERE SPECIFICALLY NOTED OTHERWISE, 8. TRIM ACCESSORIES SHALL COMPLY WITH ASTM C-1047. PLUMBING-BREAK ROOM FIXTURES 7. COORDINATE THE WORK OF ALL TRADES. PROVIDE CARPET"WALK-OFF MATS"TO PROTECT EXISTING WALL CONSTRUCTION EXECUTION 6. EXIT LIGHTS:RUUD LIGHTING"PLASTIC LED EXIT SIGN"MODEL EXPBURWH RED LETTERS,WHITE HOUSING, u 1. REUSE EXISTING FIXTURES WHERE POSSIBLE. WITH BATTERY BACKUP. CARPETS. 1. FASTEN FRAMING MEMBERS TOGETHER BY WELDING OR BY USING SELF-DRILLING OR SELF-TAPPING WHERE NEEDED,CONTRACTOR TO FURNISH AND INSTALL NEW DRY TYPE TRANSFORMERS TO PROVIDE WORK INCLUDED BUT PERFORMED UNDER SEP. PERMIT 8. ALL ROOF PENETRATIONS FROM ABANDONED EQUIPMENT TO BE REMOVED. PATCH AND REPAIR ROOF SCREWS. WELDING SHALL CONFORM TO AWS D13 WELDING PROCEDURE. ELECTRODES AND SCREW 2• BREAK ROOM SINK ELKAY G£CR2521 7. 208V/120V POWER FROM THE 480V/277V SYSTEM. SIZE TO BE BIDDER DESIGN. MEMBRANE AS NEEDED. CONNECTIONS SHALL BE AS REQUIRED AND INDICATED IN THE DESIGN CALCULATIONS. DO NOT FIELD WELD 3. KITCHEN FAUCET DELTA 100-DST a. TRANSFORMERS TO BE ENERGY STAR LABELED. PLUMBING WORK MATERIALS LIGHTER THAN 18 GA.9. ALL ROOF WORK TO BE PERFORMED BY PACTRUST APPROVED ROOFING COMPANIES. APPROVED 4. 114"COPPER WATER LINE W/SHUT OFF VALVE FOR COFFEE MAKER AND REFRIGERATOR,SEPARATE LINES 1F b. CASE fi0 BE TOTALLY ENCLOSED WITH LOUVERS TO PREVENT FOREIGN OBJECTS INTO THE INTERIOR. 9 I FIRE PROTECTION SPRINKLERING COMPANIES INCLUDE: 2. PROVIDE ACCURATELY ALIGNED RUNNERS AT TOP AND BOTTOM OF PARTITIONS. ANCHOR TRACKS AS REQUIRED. r INDICATED IN THE DESIGN CALCULATIONS. BUTT WELD JOINTS IN TRACKS OR SPLICE WITH STUD INSERTS. c. ENCLOSED AND VENTILATED,AIR COOLED TYPE,CLASS H INSULATION,DESIGNED FOR 115 DEGREES C Q HEATING,VENTILATION AIR CONDITIONING WORK a. ANDERSON ROOFING, (503}294-0202 FASTENERS SHALL BE AT LEAST 31NCHES FROM THE EDGE OF CONCRETE SLABS. 23 00 00 HVAC :DESIGN/BUILD TEMPERATURE RiSE ABOVE 40 DEGREES C AMBIENT TEMPERATURE AT FULL LOAD CONTINUOUS ELECTRICAL WORK,BOTH LINE VOLTAGE AND LOW VOLTAGE b. PACIFIC ROOFING (503)6403163 3. CUT STUDS SQUARE AND SET WITH FIRM BEARING AGAINST WEBS OF TOP AND BOTTOM TRACKS. POSITION GAS METER OPERATION. EQUIP WITH 2-1/2 PERCENT ANFC TAPS AND FOUR 2-12 PERCENT BNFC TAPS. MAXIMUM c. GRIFFITH ROOFING (503)6431596 STUDS VERTICALLY IN TRACKS AND SPACE AS INDICATED IN DESIGN. DO NOT SPLICE STUDS. PROVIDE AT 1. CONTRACTOR TO VERIFY GAS METER AND TAG METER WITH THE TENANTS ADDRESS OR SUITE NUMBER. SOUND LEVEL SHALL BE NEMA STANDARD WITH ISOLATION DAMPERS BETWEEN THE CORE AND COIL LEAST TWO FULL HEIGHT KING STUDS AT DOORS AND OTHER OPENINGS 2 FEET WIDE OR LARGER. PROVIDE METER IDENTIFICATION NUMBER AND TENANT ADDRESS INFORMATION SHALL BE GIVEN TO PACTRUST PRIOR ASSEMBLY AND CASE. •, 10.KEEP THE AREA OF WORK FREE OF GARBAGE AND DEBRIS ON A DAILY BASIS INCLUDING DOCK ACCESS JACK STUDS OVER OPENINGS,AS NECESSARY,TO MAINTAIN INDICATED STUD SPACING. PROVIDE TRIPLE TO TENANTS MOVE-IN. 9. FOR FLOOR POWER AND DATA ACCESS IN BUILDINGS WiTH ACCESS BELOW FLOOR,USE WIREMOLD RC7 AREAS AND COMMON AREA. FLOORS TO BE SWEPT OR VACUUMED DAILY. STUDS AT CORNERS,POSITIONED TO RECEIVE INTERIOR AND EXTERIOR FINISHES. FASTEN STUDS AT TOP FLUSH POKE-THRU SERIES OR EQUAL. FOR SLAB ON GRADE INSTALLATIONS USE RACO#5511,2 AT EACH 11. HVAC-BID PROCEDURE PROVIDE ADEQUATE PROTECTION TO ALL EXISTING IMPROVEMENTS INCLUDING BUT NOT LIMITED TO AND BOTTOM TRACKS BY WELDING OR SCREWING BOTH FLANGES TO THE TRACKS. LOCATION TO SEPARATE POWER AND DATA WITH 1"CONDUIT FOR POWER AND 2"CONDUIT'FOR DATA. BUILDING INFORMATION TENANT INFORMATION COMMON CORRIDORS AND STAIRS,BUILDING ENTRANCES,SUITE ENTRANCES,ETC. THE CONTRACTOR WILL 4. INSTALL ALL INTERIOR AND EXTERIOR GYPSUM BOARD PRODUCTS AND ACCESSORIES AS REQUIRED FOR 1. FOR BIDDING PURPOSES,THE HVAC CONTRACTOR WILL ASSUME THAT EXISTING HVAC EQUIPMENT is iN 10.TELECOMMUNICATION SYSTEM BY FUTURE TENANT. rA m BUILDING OWNER: TENANT: pbc188-800 SPEC SPACE BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGES TO EXISTING IMPROVEMENTS DUE TO CONSTRUCTION THE PROJECT PROPER WORKING ORDER. ACTIVITIES. ION WORKERS SHALL NOT USE BUILDING UNIT 12.00CUPANCY CONTROL DEVICES SHALL BE LEVITON OR WATT STOP.I I.LIGHTING ENERGY MANAGEMENT IS REQUIRED IN ALL BUILDINGS. PACIFIC REALTY ASSOCIATES,L.P. 5. COMPLY WITH USG GYPSUM CONSTRUCTION HANDBOOK AND MANUFACTURER'S RECOMMENDATIONS. 2. INVENTORY EXISTING H.V.A.C.ROOFTOP UNITS AND SUBMITTOARGHRfCT A CONDITIONS REPORT OF EACH 15350 SW SEQUOIA PKWY#300 OCCUPANCY: B/S-2 12.PROVIDE TEMPORARY SANITARY FACILITIES. CONSTRUCT RESTROOM FACILITIES. 6. FINISH QUALITY: 3. LIST TONNAGE OF EACH UNIT. 13.TEST ALL LIGHTING CONTROL SYSTEMS TO ENSURE THATCONTROL DEVICES,COMPONENTS,EQUIPMENT a N PORTLAND,OR 97224 13.STORAGE AND STAGING OF CONSTRUCTION MATERIALS SHALL BE LIMITED TO AREAS AS DESIGNATED AT AREA PROCESS TRADE NOMENCLATURE AND SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND FLOOR AREA PRE-CONSTRUCTION MEETING. UNDER NO CIRCUMSTANCES SHALL BUILDING UTILITY AREAS OR ANY OTHER HVAC-DESIGN PROCEDURE SPECIFICATIONS. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THAY OPERATE • N (503)624-6300 (PHONE) B 2,984 SF WAREHOUSE TAPE/FINISH COAT* TIGHT DOUBLE ch COMMON BUILDING AREA BE USED FOR STORAGE. USE EXISTING AND/OR NEW EQUIPMENT TO DESIGN MECHANICAL H.V.A.C.SYSTEM PER DESIGN STANDARDS IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. 01 (503)624-7755(FAX) S-2 9,820 SF OFFICEIOTHER AREAS TAPE/2 FINISH COATS*/ SMOOTH FINISH TAPED LiSTED BELOW. ,�� 8 14.KEEP THE ROOF FREE OF DEBRIS{L£.NAILS,SCREWS,BOTTLES,ETC.)ATALLTIMES. 14.REQUIRED IN DIVISION 15,PROVIDE MONITORING OF HVAC EQUIPMENT PER CODE. USG"FIRST COATent- *SAND AFTER TAPE/FINISH COAT(S) PRIOR TO AWARD OF CONSTRUCTION CONTRACT,H.V.A.Q CONTRACTOR SHALL SUBMIT TO ARCHITECT FOR t-. TOTAL 12,804 SF 15.ALL DIMENSIONS ARE TO FACE OF GYPSUM BOARD UNLESS OTHERWISE NOTED. 15.REMOVE ALL UNUSED DATA AND POWER BOXES AND INFILL WITH GYP BOARD. EXCEPTION-UNUSED DATA 7. FINISH EXPOSED INTERIOR GYPSUM BOARD WALLS AND CEILINGS SMOOTH STRAIGHT READY FOR FINISH AS REVIEW AND APPROVAL A FULL DESIGN SCHEMATIC FOR THE TENANT SPACE INCLUDING BOTH BOXES UNDER WINDOW SILLS TO REMAIN. ALL BLANK COVER PLATES TO BE BUILDING STANDARD FINISH. W BLDG.#. PBC BLDG. O (pbc180) 16.CONFIRM SIZES OF ALL OPENINGS REQUIRED FOR THE INSTALLATION OF STRUCTURAL,MECHANICAL, SHOWN ON PLANS. NEW/RENOVATED WORK AND SYSTEMS UNTOUCHED BY THE TENANT IMPROVEMENT AS APPLICABLE. W (4 C4 ELECTRICAL AND PLUMBING WORK PRIOR TO FRAMING OR CUTTING FOR INSTALLATION. INCLUDE THE FOLLOWING: 16.REMOVE ALL UNUSED LOW VOLTAGE WIRING(TELEPHONE AND DATA)FROM THE RECEPTACLE TOTHE �c�O 09 53 00 SUSPENDED ACOUSTICAL CEDING DISTRIBUTION BOARD.LEAVE PULL STRINGS FROM THE BOX TO THE SPACE ABOVE THE CEILING. A SECTION ). r•,.-. CONST.TYPE.: 111$ 17.LEAVE THE PROJECT CLEAN AND READY FOR OCCUPANCY, a. DUCTING AND SiZES OF THE EXISITNG LOW VOLTAGE WIRE MAY BE LEFT IN LIEU OFA PULL STRING W en cn 1. COMPLY WITH CURRENT SEISMIC REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE. in O CCC 18.CLEAN ADJACENT EXTERIOR AREA,I.E.WALKS,EXTERIOR GLASS,ETC. b. SUPPLY AND RETURN LOCATIONS AND CFM O OFFICE LIGHTING 2. FOLLOW MANUFACTURERS PRINTED INSTRUCTIONS FOR THE DELIVERY AND INSTALLATION OF CEILING m cu`✓ 19.FILL ALL PAPER AND SOAP DISPENSERS IN RESTROOMS AND BREAK AREAS. . ROOF EQUIPMENT,SIZES AND LOCATIONS SYSTEM,INCLUDING GRID,PANELS,AND HANGARS AND ACCESSORIES. 1. GROUP RE-LAMP EXISTING FLUORESCENT LIGHTS THROUGHOUT U.N.O. kn a W THIS BUILDING HOUSES TWO SEPERATE TENANTS INCLUDING THIS TENANT. THE EXISTING 20.PROVIDE"AS-BUILT"DRAWINGS OF THE WORK AT THE CONCLUSION OF CONSTRUCTION."AS-BUILT` d. UNITS REQUIRING DUCTED SMOKE DETECTION V-4BUILDING IS A SINGLE STORY BUILDING OF 27,500 SF AND IS FULLY SPRINKLERED. THERE IS DRAWINGS MAY BE iN THE FORM OF TWO COPIES OF CONSTRUCTION DOCUMENTS MARKED-UP WITH RED 3. USE ALL PRODUCTS FROM ARMSTRONG WORLD INDUSTRIES,INC. 2. OFFICE LIGHT FIXTURES- LITHONUA 2ES8P F 232 MVOLT ADVANCE OR EQUAL.(NO SYLVANiA BALLASTS) FRONTAGE ON ALL FOUR SIDES OF AT LEAST 100'FEET. e. THERMOSTAT LOCATIONS AND ZONE/UNIT ASSOCIATED THEREWITH PEN.DELIVER RECORD DRAWINGS TO THE ARCHITECT. COMPLETE OPERATION AND MAINTENANCE MANUALS 4. CO-ORDINATE CEILING WORK WITH INSTALLERS OF RELATED WORK INCLUDING BUT NOT LIMITED TO 3. OPEN OFFICE LiGHT FIXTURES- FOCAL POINT-VERVE 11 FV2S-PS-3T8.2C-277-2-C48-M WH-00 SHALL BE PROVIDED FOR ALL MECHANICAL,ELECTRICAL AND PLUMBING EQUIPMENT.PACTRUST MAY HOLD INSULATION,GYPSUM BOARD,LIGHT FIXTURES,MECHANICAL SYSTEMS,ELECTRICAL SYSTEMS AND FIRE f. ANY SUPPLEMENTAL EXHAUST FANS OR SPECIAL SYSTEMS 4. CONFERENCE ROOM- FOCAL POINT-VERVE IV FV4S-RB-DR4-3T8-X-277 2 C48-W01alVFl-00 CONTRACTOR'S FINAL PAYMENT UNTIL"AS-BUILT'DRAWINGS AND O&M MANUALS HAVE BEEN RECEIVED SPRINKLERS g. ZONE DIAGRAM ACTUAL BUILDING AREA TOTALS AND APPROVED. 5. PRODUCTS: HVAC DESIGN STANDARDS 5. WALL WASH LIGHT- FOCAL POINT -ID FC44-32TT-3-277-SO-T-L836- D WH 21.IT LS THE INTENT OF THE CONTRACT DOCUMENTS THAT THE CONTRACTOR PROVIDE A COMPLETE, 6. REST ROOM-WALL MOUNTED LIGHT FIXTURE - LITHONIA WC 2 32 MVOLT GEB101S OR EQUAL B OCCUPANCY = 16,246 SF a. GRID-PRELUDE 24 XL 15116"EXPOSED TEE{HEAVY DUTY) FUNCTIONING PROJECT INCLUDING ALL GENERAL,MECHANICAL AND ELECTRICAL CONSTRUCTION REQUIRED THE FOLLOWING ARE MINIMUM DESIGN STANDARDS: S-2 OCCUPANCY = 11,254 SF TO FULFILL THAT INTENT. ALL ITEMS REQUIRED SHALL BE FURNISHED AND INSTALLED,REGARDLESS OF b. TILES-ARMSTRONG FISSURED ITEM#I 705,24 x 24 x 5/8"W/ANGLED TEGULAR EDGE 1. 350 SQUARE FOOT PER TON. WHETHER OR NOT SHOWN ON THE DRAWINGS. c. ACCESSORIES-MANUFACTURERS'STANDARD TOTAL 27,500 SF 2. ADDRESS LOADS BY SPECIFIC LOCATION AND USE AS WELL AS CRITERIA PROVIDED TO PACTRUST BY 22.ITEMS OR WORK NOT TO BE FURNISHED OR ACCOMPLISHED BY CONTRACTOR ARE NOTED"N.I.C.". 6. ALL TILE CUTS SHALL BE DONE WITH RAZOR SHARP KNIVES. CUTITRIM TILE EDGE TO CREATE TEGULAR EDGE TENANT PRIOR TO CONSTRUCTION: 0 m MIXED OCCUPANCY NON-SEPERATED USES. IBC 508.3.2 23."ALIGN"AS USED IN THESE DOCUMENTS,MEANS TO ALIGN THE FINISHED FACES OF ELEMENTS IN THE SAME CONDITION SO THAT CEILING TILES LAY FLAT. a. EXTERIOR EXPOSURE AREAS � ( ) PLANE,EITHER IMMEDIATELY ADJACENT TO ONE ANOTHER OR ACROSS AN OPENING. 7. AT CEILINGS OVER 144 SF PROVIDE HORIZONTAL RESTRAINT WIRE OR RIGID BRACING. � 00 11 b. INTERIOR AREAS,SIZE AND USE � 24.DO NOT DISASSEMBLE SETS OF CONSTRUCTION DRAWINGS.DRAWINGS ARE INTERRELATED. 8. INSTALL CEILING GRID WITH TWO EDGES ATTACHED TO ADJACENT WALLS. THE OTHER TWOEDGES SHALL BE V-4 ALLOWABLE AREA F0104 '* 0 25.SUBMIT SAMPLES OR DRAW DOWNS FOR ALL FINISHES REQUESTED TO THE ARCHITECT OF RECORD WITHIN ATTACHED TO WALL MOLD USING BERC2 CLIPS ALLOWING THOSE TWO SIDES ALLOWED TO FLOAT. c. CONFERENCE/TRAINING ROOMS TWO WEEKS OF PROJECT AWARD.PRODUCTS INSTALLED WITHOUT APPROVED SAMPLES ARE SUBJECT TO 9. PROVIDE CEILING SEISMIC JOINTS AT LOCATIONS AS SHOWN TO LIMIT CONTIGUOUS CEILING GRID AREAS TO d. COMPUTER/SERVER AND TELEPHONE ROOMS TO HAVE PROVISION FOR LOW AMBIENT OPERATION CDVED4 S-2 26,000+(200%INCREASE FOR SPRINKLERS)=78,000 SF REPLACEMENT AT CONTRACTOR COST. NO MORE THAN 2500 S.F. AND 24-HOUR USE. losl IL B 19,000+(200%INCREASE FOR SPRINKLERS)-57,000 SF 26.SUBMIT COMPLETE SHOP DRAWINGS FOR MILLWORK,SPECIAL SYSTEMS,MECHANICAL,ELECTRICAL AND 3. SYSTEM DESIGN CRITERIA-SIZE ZONES FOR 3-5 TON UMTS BASED ON USE&EXPOSURE CRITERIA. 10.PROVIDE RIGID STRUTS TWELVE FEET ON CENTER EACH WAY BEGINNING WITHIN SIX FEET OF PERIMETER �t PLUMBING SYSTEMS(INCLUDING FIRE PROTECTION SYSTEMS). SUBMIT MINIMUM OF TWO COPIES OF ALL EDGE. INSTALL SWAY BRACING EACH STRUT ALONG FIXED EDGE IN ALL FOUR DIRECTIONS PACKAGED OR SPLIT SYSTEM EQUIPMENT GREATER THAN 5TONS SHALL BE SPLIT INTO MULTIPLE ZONES. JAN 1 O 2013 SHOP DRAWINGS FOR REVIEW AND APPROVAL TO THE ARCHITECT OF RECORD.ARCHITECT WILL RETAIN ONE VAV OR WATER SOURCE HEAT PUMP SYSTEMS GREATER THAN 3TONS SHALL BE SPLIT INTO MULTIPLE t I- COPY AND ONE COPY WILL BE RETURNED TO THE CONTRACTOR. 11.IN EXISTING SPACES REPLACE WATER STAINED OR DAMAGED TILES. ZONES. CITY .TPGARD � Q M 6W 12ND AvENUE 27.THE DESIGN OF FIRE PROTECTION SYSTEMS IS THE RESPONSIBILITY OF THE FIRE PROTECTION SYSTEMS 12.TUNE UP GRID SYSTEM TO WITHIN PLUS OR MINUS 0.5 INCHES OF LEVEL. 4. ALL ENCLOSED ROOMS OR OFFICES TO HAVE DUCTED SUPPLY&RETURN GRILLES, y yViI�I � f DIVISION w� --� - ,---- - CONTRACTOR.ALL FIRE PROTECTION SYSTEMS SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER 13.BENT OR DAMAGED T-BARS TO BE REPLACED. 5. VACANT SPACE SHALL HAVE DEDICATED GAS SERVICE FSR FUTURE BUILD-OUT OR FREEZE PROTECTION. $.TVI Y IOIO -� - LICENSED BY THE APPROPRIATE JURISDICTION FOR THE DESIGN OF THIS TYPE OF SYSTEM. COORDINATE z ._ n n INTERFACE WITH EXISTING BUILDING SYSTEMS AND WITH ARCHITECT. ALL SPRINKLER HEADS SHALL BE 14.REPAIR HOLES IN GRID FROM REMOVED WALLS, USE OF ARMSTRONG"BP ES-4"EXPANSION SLEEVE 6. UNITS: LENNOX,TRANS,YORK OR CARRIER-71/2-TON MAXIMUM UNIT SIZE. ANY UNIT IN EXCESS OF 7112 I••�i A ` CENTERED IN CEILING TILE(OR 2 x 2 MODULE OF A SECOND LOOK 11 TYPE OF CEILING TILE WHERE ACCEPTABLE. TONS SHALL HAVE SPECIAL APPROVAL BY BUILDING OWNER. A B � F r f L r APPLICABLE). LOCATION OF THOSE IN GYPSUM BOARD CEILINGS SHALL BE PRE APPROVED IN WRITING BY 09$S 1$RESILIENT FLOORING-SHEET VINYL FLOORING THE ARCHITECT PRIOR TO INSTALLATION. 7. HVAC UNITS WITH EQUAL TO OR GREATER THAN 5-TONS TO HAVE DUCT SMOKE DETECTORS AND BE j CONNECTED TOA IN HIN THE BUILDING. I 28.CooRDINATE ALL CONSTRUCTION SEQUENCING WITH PACTRUST AND SCHEDULE ALL SERVICE 1. SEAL THE EDGES N THE SHEET VINYL FLOORING E I THE CONCRETE FLOOR WITH A CONTINUOUS BEAD OF g ROOF TOP UNITS SHALL BE PLACED 24'MINIMUM FROM ROOF EDGE TO CENTER OF UNIT. MULTIPLE UNITS 0 05 0 INTERRUPTIONS OUTSIDE NORMAL BUSINESS HOURS TO MINIMIZE INCONVENIENCE TO CURRENT TENANTS. APPROVED SEALANT. SET THE 6"ViNYL COVE BASF INTO A FRESH BED OF SEALANT TO SEAL THE BASE TO p I S THE SHEET VINYL. MITER THE CORNERS AND APPLY A BEAD OF SEALANT TO SEAL THE JOINT. SHALL BE PLACED SYMMETRICALLY IN A LINE BASED ON STRUCTURAL CALCULATIONS BY ENGINEER. 0 r✓ cam_ / GENERAL 09 6519 RESILIENT FLOORING-VINYL COMPOSITION TILE 9. CURBS: 14"CURBS. ASSEMBLED AND LEVELED TO ROOF,ANCHORED TO STRUCTURAL MEMBERS BELOW {� C' � / 1. REMOVE ALL EXISTING VCT,SHEET VINYL,ETC.IN AREAS WHERE NEW FLOOR COVERING IS SPECIFIED PRIOR ROOFING. �� 1. EXTEND FINISH FLOORING UNDER CASEWORK. TO INSTALLATION OF NEW FLOORING. a. PROFESSIONALLY ROOF IN ALL CURBS AND PENETRATIONS BY PACTRUST APPROVED ROOF E �i � 2. INSTALL TILES IN QUARTER TURN PATTERN. Q -1 / '� N 2. ALL ROOF PENETRATIONS FOR ELECTRICAL,LOW VOLTAGE,GAS PiPING,ETC.SHALL BE SLEEVED THROUGH CONTRACTOR, SEE DIVISION 1 GENERAL NOTES THIS PAGE. r I p A LEAD ROOF JACK,CLAMPED WITH A STAINLESS STEEL CLAMP AND SEALED WITH VULKEM 921 09 91 23 PAINTING b. UNIT MUST BE LEVEL,SEALED WITH NO AIR LEAKS AND COUNTER FLASHED. "o, 'f r//, POLYURETHANE SEALANT. SILICONE SEALANT NOT PERMITTED. c. CONDENSATE MUST BE TRAPPED AT UNIT. o S H 01 73 29 CUTTING AND PATCHING11b 1M yyA ; 10.SEISMICALLY ATTACH UNIT TO CURB IN CODE-APPROVED METHOD. 0 1. PERFORM CUTTING AND PATCHING WITH SKILLED CRAFTSMEN EXPERIENCED WiTH THE TYPE OF WORK a. PRIME NEW DRYWALL WITH MILLER'S HIGH-BUILD"SUPER SERI"PRIMER. 11.ALL GAS PIPING SHALL BE STANDARD BLACK STEEL PIPE W1 SUPPORTS PER CODE. PIPING SHALL BE RUN G17 M BEING UNDERTAKEN. INSIDE OF BUILDING W/LEAD FLASHINGS AT ROOF PENETRATIONS. LEAD ROOF JACKS TO BE SEALED AND 2. PROTECT EXISTING CONSTRUCTION TO PREVENT DAMAGE. b. NEW AND EXISTING DRYWALL IP BE FINISHED TO ACHIEVE UNIFORM COVERAGE WITH LATEXMILLER'S AME 0R CLAMPED(S.S.WORM GEAR 4480 WITH A TIGHT ROLLER STIPPLE FINISH. RESTROOM FINISHES TO BE MILLER'S S/G LATEX ENAMEL. ). r 3. PERFORM CUTTING USING METHODS LEAST LIKELY TO DAMAGE ELEMENTS TO BE RETAINED. 2. CEILINGS: 12.ALL EXISTING AND NEW GAS PIPING EXPOSED TO THE EXTERIOR TO BE PROTECTED FROM RUST AND a I 4. PATCH,USING MATERIALS IDENTICAL TO EXISTING MATERIALS THAT VISUALLY MATCH EXISTING ADJACENT e. EXISTING GYP BOARD/PLASTER-SAND,SPACKLE ALL IMPERFECTIONS,SPOT PRIME AND FINISH TO CORROSION WITH OIL BASED PAINT(COLOR GREY). 0 J� , € BUILDING LOCATION SURFACES TO THE FULLEST EXTENT POSSIBLE 13.LOW VOLTAGE IN SEALTITE CONDUIT FROM BELOW ROOF LINE DIRECT TO UNIT. DO NOT EXCEED BEND ACHIEVE UNIFORM COVERAGE WITH MILLER'S 62000R 4480. 4 5. PATCH WITH DURABLE,INVISIBLE SEAMS THAT ELIMINATE EVIDENCE OF PATCHING AND REFINISHING. RADIUS MANUFACTURER'S GUIDELINE. b. NEW GYP BOARD 1 PLASTER -PRIME WITH SUPER SEAL AND FINISH TO ACHIEVE UNIFORM COVERAGE &NN4 6. AT CONCRETE SLAB REPAIRS(POUR BACKS),PROVIDE 93 x 12"LONG REBAR DOWELS AT 24'O.C. MN.WITH WITH MILLER'S 6200 OR 4480. 14.ECONOMIZER TO MEET CODE AND AS FOLLOWS: MIN.2"PENETRATION INTO EXISTING CONCRETE AND MIN.OF 10"EXPOSURE INTO POUR BACK CENTER a. 6 TONS AND ABOVE MUST HAVE ECONOMIZER. ��^e t0 1'8C I t it DOWEL IN SLAB. 3. GENERAL NOTES: } LOCATION MAP m 7. REMOVE PATCHES THAT ARE VISUALLY UNSATISFACTORY IN THE ARCHITECTS OPINION AND REPLACE AT NO a. KEEP ALL HARDWARE,HINGES,AND DOOR KNOBS CLEAN OF ALL PAINT SPLATTERS,GRIPS,OR ROLLER b. BAROMETRIC RELIEF ON 5-7112 TON UNITS. Z ADDITIONAL COST. SPRAY. c. 8 TONS AND ABOVE MUST HAVE POWER EXHAUST. A-1 NOT TO SCALE 07 0000 THERMAL S MOISTURE PROTECTION b. ALL SURFACES TO BE SANDED BETWEEN COATS,PRIOR TO INSTALLATION OF NEXT COAT. d. 1 12 THRU 4-TON OSA INTAKE WITH DAMPER. 1. REPLACE ALL MISSING AND DAMAGED ROOF AND WALL INSULATION ABOVE THE CEILING GRID. c. DURING PROGRESS OF WORK,KEEP JOB SITE CLEAN OF ALL PAINT MATERIALS,RUBBISH,CANS,AND 15.ALL UNITS TO MEET OR EXCEED CURRENT ENERGY EFFICIENCY CODE REQUIREMENTS. RAGS AT THE ENO OF EACH DAY. i e T e d a a ' 16.DROP CANS TO FULL SIZE OF UNIT CURB OPENING. MINIMUM CLING.GAUGE WITH SUPPLY AIR. EDGES OF SUPPLY 2. PROVIDE NEW ROOF INSULATION TO MATCH EXISTING AT ABANDONED MECHANICAL UNITS. d. UPON COMPLETION OF WORK,GLEAN ANY PAiNT SPLATTER BY USING PROPER METHODS OF WASHING AIR SEALED. DROP CANS TO BE EXTENDED TO WITHIN 2'OF CEILING. 00= €MA 3. AT ALL UN-USED EXISTING ROOF PENETRATIONS,REMOVE EQUIPMENT AND REPAIR ROOF SYSTEM. AND SCRAPING,USING CARE NOT TO SCRATCH OR DAMAGE FINISHED SURFACES. 17.DISTRIBUTION DUCTWORK: a o 0810 00 DOORS AND WINDOWS a. SPIRAL ONLY IF EXPOSED.e. PROTECT WORK OF OTHER TRADES. &W04 8 1 1. RE-USE EXISTING DOORS AND FRAMES WHERE POSSIBLE f. PROVIDE'WET PAINT"SIGNS AS REQUIRED TO PROTECT NEWLY PAINTED FINISHES. 00 ill b. 26 GAUGE OR TO SMACNA STANDARDS IF PIPE IS CONCEALED ABOVE DROP OR HARD CEILING. 9 2. APPROVED DOOR,FRAME,AND HARDWARE SUPPLIERS INCLUDE: 10 00 00 SPECIALTIES �} 4t: c. WRAP CONCEALED SUPPLY DUCTWORK N NON-CONDITIONED AND SEMI-CONDITIONED SPACE WITH € € a. BAXTER AND FLAMING. {503}225-0488 #028 13 REST ROOM ACGESSORiES(SINGLE OCCUPANCY) MINIMUM R4.2 INSULATION WITH FSK BARRIER. in 00 - N I I b. D&D DOOR (503)205-5533 1. REUSE EXISTING ACCESSORIES WHERE POSSIBLE. d. HANGERS 12 GAUGE WIRE OR 18-GAUGE 1"WIDE STRAP. EXPOSED DUCT MUST HAVE ALL THREAD4 � e r _ c1 I . BENSON INDUSTRIES (503)907-2200 2. PAPER TOWEL DISPENSER,SURFACE MOUNTED(ONE PER REST ROOM)BOBRICK 8-262 HANGERS NGGERS AND FULL DIAMETER STRAP UP TO 18"0. LARGER THAN 18"MUST HAVE SADDLE TYPE � MP. Go 04 1 1 1 € 1 1 t I d. GRANT SUPPLY (360)887-0647 3. SURFACE WALL MOUNTED SOAP DISPENSER BOBRICK 8-4112(use with wall hung sink) e. BRANCH DUCTS SHALL BE PLUMB AND SQUARE(NO OCTOPUS). TEES SHALL BE MAXIMUM OF 45 ,, 0 `D 0 f Ic 3. DOOR AND RECITE FRAMES SHALL BE TIMELY,OR APPROVED. SUBMITTAL REQUIRED PRIOR TO ORDERING 4. SURFACE MOUNTED MULTI-ROLL TOILET TISSUE DLSPENSER BOBRICK 8-2888 DEGREES. �t � iMATERIAL.NEW FRAMES TO BE FACTORY FINISH CUSTOM COLOR. 5. SURFACE MOUNTED TOILET SEAT COVER DISPENSER BOBRICK B-4221 f. EACH BRANCH DUCT TO HAVE BALANCE DAMPER IN Y BRANCH. t 4. FIELD VERIFY EXISTING DOOR,FRAME AND HARDWARE FINISH PRIOR TO ORDERING. ALL NEW DOORS U r% A 6. MIRROR STANDARD SIZES 1/4"PLATE MIRROR WITH EDGES"FLAT GROUND"BOTTOM EDGE SUPPORTED BY A g. ALL DISTRIBUTION DUCT WORK TO BE INSTALLED MIN.24"ABOVE FINISH CEILING. \ � I FRAMES AND HARDWARE TO MATCH EXISTING BUILDING STANDARDS. CONTINUOUS BRIGHT CHROME"J"METAL,5116"X 318" (HEIGHT OF EXPOSED FACE)WITH CONCEALED LEG vl. I,I,J : a 18.FLEX DUCT WILL BE NO LONGER THAN 6'FROM RIGID DUCT DOWN TO DIFFUSER. I- __ I nfl I I I r_1Lfr1L__ I � 5. ALL INTERIOR DOORS SHALL BE SOLiD CORE WOOD UNLESS NOTED OTHERWISE. SCREWED TO THE WALL TO CARRY THE WEIGHT OF MIRROR. 0 9 CA o- - - - 7. GRAB BAR SATIN FINISH BOBRICK B-6806 SERIES 19.DIFFUSERS: �( 00 1x 6. DOOR HARDWARE SHALL BE SCHLAGE AL SATURN OR D RHODES SERIFS U.N.O. � � � � a. SUSPENDED CEILING SYSTEM{T-BAR}-PERFORATED FACE ADJUSTABLE CURVED BLADES-DESIGN 1 CV Q 7. ALL DOOR HARDWARE SHALL BE INSTALLED WiTH A T BACKSET. 10 2818 BREAK COUNTER TUTUS PCS SUPPLY AND TUTUS PAR RETURN OR APPROVED EQUAL. a+ n P �A OF WORK 8. DOOR FINISH SUBMITTAL:CONTRACTOR TO PROVIDE SWOP DRAWINGS FOR DOOR FRAMES,DOOR 1. PAPER TOWEL DISPENSERS,SURFACE MOUNTED(KITCHENiBREAK ROOM)190BRICK 8262 b. GYP.BD.CEILING;SUPPLY-CURVED BLADE W/OBD DESIGN TITUS 250;RETURN-BAR TYPE-DESIGN CITY OF TIGA D HARDWARE AND DOORS AS WELL AS A CONTROL SAMPLE OF THE FINISHED DOOR SKIN W/STAIN AND FINISH 10 4416 FIRE EXTINGUISHERS TITUS 350;EXHAUST-METAL OR ALUMINUM-12"x 12"EGG CRATE DESIGN TITUS 50F. "�'1 " " q----",* y.�"' REVISIONS �j��+�/"���5 APPLIED(IF NEW DOORS ARE BEING PROVIDED). BEFORE FINISHING OF DOORS IS COMMENCED ARCHITECT Approved"-•...."-.-.Ll............ * �7 REV S7 V til SHALL APPROVE CONTROL SAMPLE. FINISHED PRODUCT IS SUBJECT TO REJECTION BY ARCHITECT IF THIS 1. FIRE EXTINGUISHER 2A10 BC (WALL MOUNTED OR IN SEMI RECESSED CABINET AS INDICATED ON PLAN) c. ALL SUPPLY REGISTERS TO HAVE MANUAL VOLUME DAMPERS LOCATED IN DUCT ATIOR NEAR CLOSEST Conditionally App PROCESS IS NOT FULLY ADHERED TO AND FIELD PRODUCT DOES NOT MATCH THE APPROVED CONTROL 2. FIRE EXTINGUISHER CABINET: JL INDUSTRIES ACADEMY SERIES MODEL#tC1027V10. WYE BRANCH. roved C I 2 BUILDING PLAN SAMPLE. d. CLEAN OR REPLACE ALL SUPPLY AND RETURN AIR GRILLS AND THEIR HOUSINGS AT PROJECT See Letter to:Fo!low,""""'"w_"",»""."C I v SCALE I"=60' 9. ALL INTERIOR GLAZING SHALL BE TEMPERED. 11 00 00 EQUIPMENT COMPLETION. Auac le,d............... Add#1 12/3/12 N 1. DISHWASHER: ASKO-D3112 ADA,OR EQUAL APPROVED BY PACTRUST. Permit Number: " "L',I,t t Rev#1 12/13/12 10.PATCH AND REPAIR ALL HOLES OR DAMAGE TO EXISTING STORE FRONT WINDOWS AND DOORS.TOUCH UP 20.THERMOSTAT: ALL EXISTING MERCURY TYPE THERMOSTATS TO BE REPLACED. NEW THERMOSTATS TO BE FINISH FOR AS NEW LOOK. 2. DOCK LEVELERS: IN ALL CASES INCLUDE TRANSITION PLATE RHE2001/4 X 108 X 12 WiTH BEND WELDED TO HONEYWELL COMMERCIAL GRADE V/SIONPRO 8000 TOUCH SCREEN MODEL T9622OUION WNEREPOSSALE Addre �� I1.TOUCH UP ALL EXISTING INTERIOR DOORS AND FRAMES FOR AS NEW LOOK EXISTING ANGLE IRON AND BOLTED TO FLOOR AT INSIDE EDGE 6"O.0 . REMOVE EXISTING DOCK BUMPERS. APPROVEDSUBSTITUTE: O L-LIN Si N L H AT P974-2800 -7 AY B . Rev#2 1/10/13 Permit SEE PLAN FOR LOCATIONS. PACTRUST APPROVED OPTIONS INCLUDE: PROGRAMMABLE WITH L FUNCTION-AU ONLY. ( Y: Date: 09 00 00 FINISHES a. RITE-HITE EDGE OF DOCK LEVELER.72"w 30k 12"LIP PROJECTION W/12 X 13 BUMPERS AND BLOCKS. REQUIRE CHANGING HEIGHT AT"REPLACEMENT"LOCATIONS). CONTRACTOR SHALL PROGRAM GENERAL /� rTHERMOSTATS AND BALANCE SYSTEM. he b. NEVERLIFT EDGE OF DOCK LEVELER MODEL NL7230 WITH BUMPERS. 21.fiHERMOSTAT LOCATIONS TO BE REVIEWED BY ARCHITECT PRIOR TO INSTALLATION. ^ 3L" 1. CLEAN,SEAL AND WAX ALL RESILIENT FLOORS PER MANUFACTURERS SPECIFICATIONS. 12 00 00 FURNISHINGS 22.WAREHOUSE HEAT: cmqlttlSyTm 2. SUBMIT SAMPLES OR DRAW DOWNS FOR THE FOLLOWING: 1. CLEAN/REFURBISH EXISTING BUILDING STANDARD BLINDS AT ALL EXTERIOR GLASS. a. GAS FIRED UNIT HEATERS USED IN NON-CONDITIONED AREAS SHALL COMPLY WITH CURRENT STATE occupwiq a. FLOOR COVERINGS AND BASE 2. REPLACE BUILDING STANDARD BLINDS AT ALL EXTERIOR GLASS AND PROVIDE BUILDING STANDARD BLINDS ENERGY CODE REQUIREMENTS. PROVIDE ADJUSTABLE T•STAT FOR EACH UNIT. C ttstt'miotlE'Tm 9 b. PLASTIC LAMINATES TO MATCH AT NEW EXTERIOR GLASS. BLINDS SHALL BE PER CURRENT PACTRUST STANDARD(WHITE, 23.EXHAUST FANS: Rood Corridor ) NON-PERFORATED.. c. ALL NATURAL WOOD(INCLUDING DOORS AND CASEWORK) VERTICAL, a. CEILING MOUNTED EXHAUST FANS SHALL HAVE A MiNIMUM PERFORMANCE TO MEET THE CURRENT 9MV Code 4"W"4"W" 3. PROVIDE BUILDING STANDARD BLINDS AT ALL EXTERIOR GLASS. CODE REQUIREMENTS INCLUDING INTEGRAL BACMDRAFT DAMPER AND VENTING TO THE EXTERIOR. 4. INSTALL BUILDING STANDARD ADDRESS AND/OR SUiTE NUMBER LABELS TO ALL EXTERIOR DOORS. d. PAINT COOK GEMINI SERIES 100 OR EQUAL;80 CFM WITH A SONE RATING OF 1.6 OR LESS,100 CFM NTH A A� u%llity e. TiLE,MARBLE,GRANITE,STONE,AND GROUT 2100 00 FIRE SUPPRESSION :DESIGN/BUILD SONE RATING OF.9 OR LESS,200 CFM WITH A SONE RATING OF 1.6 OR LESS. f. TOILET PARTITIONS b. SINGLE FIXTURE RESTROOMS,JANITOR'S CLOSETS OR SINGLE SHOWER ROOMS TO HAVE CEILING DRAWN BY: g. HARDWARE 1. PROVIDE CEI SPRINKLERS BELOW SUSPENDED SPRINKLERS BY CON RAPER CODE. SPRINKLER HEADS SHALL BE CENTERED!N 2 MOUNTED EXHAUST FANS,WIRED PER DIVISION 16 AND SWITCHED WITH THE LIGHTS. OFFICE COPY X 2 CEILING TILE.LAYOUT OF SPRINKLERS BY CONTRACTOR. SPRINKLER LAYOUT IN ALL HARD CEILING L` R.M.T. 3. EXTEND FINISH FLOORING UNDER ALL NEW CASEWORK AREAS(GYPSUM BOARD/PLASTER)TO BE REVIEWED AND APPROVED BY ARCHITECT PRiOR TO INSTALLATION. c. MULTIPLE FIXTURE RESTROOMS,COMBINATION RESTROOM&SHOWER,AND LOCKER ROOMS TO HAVE 09 2100 GYPSUM BOARD 2. IN NEW CEILING GRID SYSTEMS OVER 144 SF PROVIDE FLEXIBLE HEADS FOR MINIMUM SEISMIC MOVEMENT. ROOFTOP MOUNTED EXHAUST FAN,FACTORY CURB AND BACKDRAFT DAMPER,WIRED PER DIVISION 16, NO"OOPS RINGS ALLOWED". CONTROLS AS REQUIRED BY DESIGN.COOK ACE-0 SERIES OR EQUAL DATE: 11/27/12 GENERAL d. SPECIALTY ROOMS REQUIRING EXHAUST SHALL MEET THE ABOVE MINIMUM REQUIREMENTS- Approved plans BID I" ALL GYPSUM BOARD TO BE A MINIMUM OF 5/8"THICK VERTICALLY ATTACHED TO METAL STUDS 24"O.C.WITH 3. PROVIDE AUTOMATIC FIRE SPRINKLER FLOW INDICATOR SIEMENS GU-MHU-MCS-W OR EQUAL.SEE PLAN FOR INDIVIDUAL ROOMS WITH AN EXHAUST REQUIREMENT GREATER THAN 250 CFM,WILL REQUIRE THE USE 1"TYPE S-12 SCREWS 12"O.C.UNLESS OTHERWISE NOTED. LOCATIONS. OF A ROOFTOP MOUNTED FAN. shall be on job site,, 2. ALL OFFICE GYPSUM BOARD TO RECEIVE ONE TAPE COAT AND TWO FINISH COATS WITH SANDING BETWEEN 22 00 00 PLUMBING 24.HVAC TESTING. FINISH COATS. APPLY USG SHEETROCK BRAND FIRST COAT. PAINT AS INDICATED. GENERAL REQUIREMENTS a. CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES,COMPONENTS, 3. ALL OTHER GYPSUM BOARD TO RECEIVE ONE TAPE COAT AND ONE FINISH COAT WITH SANDING AFTER FINISH 1. CONTRACTOR TO SUBMIT LAYOUT ON ELEVATIONS AND PLANS PROVIDED FOR ALL SHUT OFF VALVES,CLEAN EQUIPMENT AND SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH COAT. PAINT AS INDICATED. OUTS,ACCESS DOORS,AND FLOOR DRAINS TO THE ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION. APPROVED PLANS AND SPECIFICATIONS. _ 4. IN FINISHED SPACES FURR-OUT BUILDING COLUMNS AND EXTERIOR WALLS WITH 518"GYPSUM BOARD OVER 2. PLUMBING CONTRACTOR TO PROVIDE AND INSTALL(1)MASTER SHUT OFF VALVE FOR EACH SET OF b. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE IN METAL STUDS. RESTROOMS. LOCATE VALVE BEHIND HANDICAP TOILET IN MEN'S RESTROOM. ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. 5. PROVIDE ACOUSTIC GASKETS WHERE WALL INTERSECTS MULLIONS OR GLAZJNG. 3. ALL DOMESTIC WATER PIPING TO BE TYPE L COPPER-NO EXCEPTIONS. ALL EXPOSED PIPING TO BE c. A COMPLETE COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND itt• FILED WITH PACTRUST. 6. AT ALL EXISTING WALLS,REMOVE ALL NAiLS,SCREWS,FASTENERS,ETC.LEFT BY PREVIOUS TENANT AND INSULATED. 25.PROJECT CLOSE OUT DOCUMENTS REQUIRED: AUILDING DEPARTMENT USE PATCH HOLES READY FOR PAINT. 4. WATER HEATER(ELECTRIC)30 GAL AND LARGER 277V LESS THAN 30 GAL 120V. PROVIDE HUB DRAIN AT LOCATION. a. AutoCAD FILE SHOWING AS-BUILT INFORMATION. ■wl�wrlr�rwr� -j � �� �• 3082 ( 5 ) (4 , 1 -" MARTIN W. HANSOM I CLA KAT S, OREGONOF ,4 XXX X � e ' I PROJECT #12680 } J I I 1 I ii CONTRACTOR TO REUSE ALL DOORS, y,. CASEWOW AND FIXTURES IN NEW ff Y CONSTRUCTION UIERE POSSIBLE. T r, } II / i mak,_ - I li 451 a;I I II 110 I I 4:T., EQ- EQ. � 1 510 M (( I 1 A H 111 lilt it III III it III[it H 1111111111111111111111 til it I I III 111111111111111111111 1[l[it 11111111 11 Ill 11111 it]111 it 11111111 t ', si 109 © n C v� _ CONFERENCE OFFICE ------------ M w O I to6 OFFICE ----------------------- ___________ = 107 109 a o I I 2 DEMO PLAN m+ k (iiSOI fT <. _ • 1@l im8 Im3 t1-2 SCALE 1/8"= 1'-0" 106 l04 B - - - - - _ - - - - -- - - - - - - - - - - -- - -- — - N (2)'5x1 (2)35 X 7 z DOUB7E I -- - i SIDELITES 51DELITESUTILI ° �45'j SINK ° 45'MICRO. �--RELOCATE CIRC. REF. LUNCI'I CASEWO — J 109 I SINK AND —I— (I 10600 DISHWASHEF2� I —1- _ — — — T — _ — — x 4-m" 6' �° 4�-O lI�I� 00I Ea 4'-m Ea I I I POWER IN I I CEILING FOR x a I 4NANT SYSTEMS I It O SC VCT CIRC. VCT LP I I I FURNITURE I ( �--------- ----------..} 4F; 61 Im3 i I � I I„ I@5 — — ■ 9 a : s � 103 1m4 - — — — � __ .._._ — � — � _._. .._._� c. I ( I krk'T * t -------- - ---- - > > ( I I ----------- j S3 - II I I I I XXxiX� i 2 j fx 03 -- - - --- - - --- - f WOMENN- -- _.. r I A 3 1 A-3 } 1 = I R I I I 2 , q -fJV 1 r 106 1{, 111 ( - - - - -I- - - - - L - - _ J ;0 1 I E I 4 Q 1 I f , MM EXTEND EXISTING EQ. 102 I WALL TO ROOF a STRUCTURE — OFFICE -__-.— — — AD I D STICK PEN INSULATION POWER M I (At EXTERIOR WALL ABOVE CEISYSTEMSLING FOR IEXISTING OFFICE 4'-5" 4_g• ,. I ,��%' (2)3.5X7 T T EVAN I SiDEL{TES � — J — — FURNITURE — OPEN OFF= ` 1 FWD I i I A 2 ENLARGED RESTROOM PLATS SCALE 1/4"= F-0" ,_ N t OFFICE f I 5XT I I I � I Tr I�� �� ( EQ. EQ. _ 101 SIDELITE w I i I - i WALL BRACKET LIGWT ,I-t 5/81 U-06 A __ _ _ _ _ ADD STICK FEN INSULATION FIBERROCK AT EXTERIOR WALL ABOVE BRAND _U EXISTING OFFICE AQUATOUGH 2'-gyp INTERIOR 3' 4° PANEL 1 PARTITION AND POWER PLAN BOBRI2 a MIRROR L� A-2 SCALE 1/8"= 1'-0" N �y � DOOR SCHEDULE __ pc pp w DOOR DATA FRAME DATA HARDWARE — � A I Fire Rating Remarks z_f o ? W A Mark Door Size Thk Core j Veneer Finish Hand Type Frame Depth Hardware Manufacturer Finish Function � C7 101 3`-0' x T-0' 1 3/4' 5C OAK WATCO Right - i TIMELY 4 l/8" PA55AGE LATCH 5CHLAGE 625 BRIGHT CHROME AL105 RELOCATED DOOR ! NEW FRAME / 5 X 1 51DELITE �, BOBRICK in 8-221 M a n 102 3'-0' x T-0' 1 3/4' 5C OAK WATCO Right • TIMELY 4 I/8" PA55AGE LATCH 5CHLAGE 625 BRIGHT CHROME AL105 (2) 3.5 X -I 51DELITE5 103 3'-0' x -1'-0' 1 3/4' 5C OAK WATCO -Right 0 TIMELY 1 1/4' CLO5ER/PA55AGE LATCH 5CHLAGE 625 BRIGHT CHROME ND105 RELOCATED DOOR AND FRAME REVISIONS 104 3'-0' x I'-0" 1 3/4" 5C OAK WATCO Right 1 TIMELY 4 l/8" PRIVACY LOCK LATCH 5CHLAGE 625 BRIGHT CHROME 5L405 RELOCATED DOOR 4 FRAME 105 3'-0' x T-O' 1 3/4' 5C 1OAK WATCO I Left 0 TIMELY 4 '1/8" PRIVACY LOCK LATCH 5CHLAGE 625 BRIGHT CHROME 5L405 RELOCATED DOOR d FRAME s'-Q" I-3, Add.#1 12/3/12 101 3'-0' x T-0' 1 3/4' 5C OAK WATCO R112ht ! TIMELY 4 1/8" PA55AGE LATCH SCHLAGE 625 BRIGHT CHROME AL105 36' 51DELITE x''-02" , -t'-2° Rev#112/13/12 106 3'-O' x T-0' 13/4' 5C OAK WATCO Left ! TIMELY 4 1/8" PA55A6E LATCH 5CHLAGE 625 BRIGHT CHROME AL105 RELOCATED DOOR / NEW FRAME / (2) 3.5 X -1 SIDELITE5 Rev#21/10/13 Permit 109 3'-O' x -I'-O' 1 3/4' 5C OAK WATCO Left • TIMELY r4_1/i" PA55AGE LATCH 5CHLAGE 625 BRIGHT CHROME AL105 RELOCATED DOOR / NEW FRAME / (2) 3.5 X 151DELITES 4 RESTROOM ELEVATIONS A-2 SCALE 1/2"= 1'-0" MEN 104(WOMEN 105 OPPOSITE HAND) FINISH SCHEDULE FINISH MATENALS ITA ALL FINISHES MUST BE SUBMITTED TO PACTRUST PRIOR TO INSTALLATION. CONSTRUCTION LEGEND WALLS CARPET LOOP PILE: RM# NAME FLOOR BASE CEILING CLG. REMARKS LP PATCRAFT 10129-NIGHT MOVES, 29703 LIONS TIGERS&BEARS,DIRECT GLUE NORTH EAST 5OUTH WEST HTWALK-OFFCARPET EXISTING TO REMAIN wOC CONNEXUSPROTEGT-1N,BROWN EXISTtNGTOBEREMOVED ' 100 OPEN OFFICE LP / E-1-P WOC 4' RF / E-4" RF E-WW-PGWB PGWB PGWB WW-PGWB SAT il'-0" -- SHEET VINYL 101 OFFICE E-LF 4' RF E-WW-PGWB E-PGWB I='GWB E-PGWB SAT - 111-0" - SV ARMSTRONG MEDINTECH,88439 DESERT GOLD, WELDED SEAMS t4 NEW STANDARD WALL DRAWN BY: 102 OFFICE LP 4' RF PGWB E-PGWB PGWB PGWB SAT 11'-0' - BASE 2 3 NEW STANDARD WALL WITH INS. R.M.T. RF BURKE MERCER 4"FLAT RUBBER BASE,597 MOCHA AT ALL CARPET AREAS. 4 4 103 CIRC. VCT 4' RC E-PGWB PGWB PGWB ---- SAT I I'-0" - RC BURKE MERCER 4"COVE RUBBER BASE,597 MOCHA AT ALL HARD SURFACES. / ® A.4 NEW STANDARD WALL WITH INS.TO ROOF STRUCTURE DATE: 11/2712 104 MEN 5V 4' RC E-PGWB PGWB PGWB PGWB WBC — 9'-0" AQUATOUGH WAINSCOT PAI PT-1 MILLER 4480 PREMIUM SATIN 8721W CLAY BEIGE,SATIN LATEX BID 105 WOMEN 5V 4" RC E-PGWB PGWB PGWB PGWB WE3C 9'-0' AQUATOUGH WAINSCOT PT-3 MILLER 6180 PERFORMANCE FLAT0 PREMIUM SATIN -MIX VW9W{WAREHOUSE WAMEADOWLARK,SATIN LATEX LLS ENT COLOR) DUPLEX RECEPTACLE ELECTRICAL PANEL 106 LUNCH VCT 4' RC PGWB PGWB PGWB PGWB SAT II'-0" - LAMINATE: FOURPLEX RECEPTACLE O POWER J-BOX 101 CONFERENCE LP 4" RF PGWB PGWB PGWB PGWB SAT III-01 -- PLA WILSONART 1530-W BEIGE,AT ALL FACES PL-2 WILSONART 4669-60 NATURAL TIGRIS COUNTER,B.S.AND SELF-EDGE D#�) DEDICATED OUTLET ® FLUSH MOUNT FLOOR MONUMENT W/POWER AND DATA 108 OFFICE LP 4' RF PGWB PGWB PGWB PGWB SAT 11'-O" - GAB PULLS 625 BRIGHT CHROME 109 OFFICE LP 4' RF PGWB PGWB PGWB PGWB SAT 11'-0" -- EXISTING ELECTRICAL TO REMAIN FER FIRE EXTINGUISHER IN RECESSED CAB. DOORS,HARDWARE AND FRAMES 110 WAREHOU5E LP 4' RF PGWB PGWB PGWB PGWB SAT 101-01 -- HARDWARE or 625 POLISHED CHROME FLOOR MONUMENT W/SERVICES SHOWN Fes FIRE EXTINGUISHER-SURFACE MOUNTED FRAMES SMOKE WHITE Jill WH RR E-5V E-4" RC E-PGWB E-PLW-PGWB E-PLW-PGWB E-PGWB I E-WBC 1 91-011 - CONTRACTOR TO PROVIDE BUILDING STANDARD BLINDS AT ALL EXTERIOR GLASS. � SPECIAL OUTLET UT THERMOSTAT TEL/DATA MUD RING WITH PULL STRING #3082 �� ' MARTIN W. HANSON ( ; �4 CLA K S, OREGON, 3 I I 1 OF � J I I PROJECT#12680 1 1 1 1 l f i 1 I I I I 1 a i 1 z I 1 i RELOCATE 1 RELOCATE QQ WAREHOUSE WAREHOUSE RELOCATE FDaURE I WARE}iOUSE HEATER 1 eyo Q Q1`y ;VA II! I aW 11'-0'CEILING HT. ❑ 0 I -i 02 ac //��yy .j o W MW DEMO ALL CEILINGS. ADJU5T i �M�/ 5pF2IWLERS AND HVAC TO NEW !f I I I CEILING HEIGHT. SEE DRAILIM I!A-3 CEILING HT. r.._ ..-t---- r._...____. R 0 r 08UNG HT. 7:4a `H 5 E� ULit y F� 3C, G' �ji,� !1 �; 19 � 1 �f' Erti� F1 - - i ,71- a �1 �.....�; ...7 i rr f ----------------------- ----------------- 7. i ._!___L_.�_._ t REFLECTED CEILING PLAN z DEMO PLAN A-3 SCALE 1/8"= 1'-0" N N A-3 SCALE 1/8"= 1'-0" v��, 2 X 2 SUSPENDED CEILING SYSTEM: Q ATTACHED EDGE cr ; (� SEISMIC EXPANSION JOINTS w O � p � UNATTACHED EDGE W GRID MAIN Q N pAli Rr [ R REVISIONS Add#112/3/12 Rev#112/13/12 Rev#21/10/13 Permit CEILING LEGEND ® 2 X 4 FLUOR.T-8 2 TUBE FIXTURE AT OFFICES ® SUPPLY DIFFUSER ® RETURN DUCT DRAWN BY: DIRECT/INDIRECT LIGHTING AT OPEN OFFICE R.M.T. ® EXHAUST FAN DIRECT I INDIRECT LIGHTING AT CONFERENCE TIE SPRINKLER HEAD DATE. 11/27/12 a WALT.WASH LIGHT THROUGHOUT BID Q EXIT SIGN(LED RED) i711J ® 2 x 4 FLUOR.T-8 S TUBE FIXTURE FIXTURE (g Ns HORNISTROBE FIRE ALARM(WALL MOUNT) ( ws 4 HORN/STROBE FIRE ALARM(CEILING MOUNT) RECESSED COMPACT FLUORESCENT LIGHT(TYP.) C6 E) SMOKE DETECTOR $ STANDARDSWITCH (1) OCCUPANCY SWITCH CEILING OCCUPANCY SENSOR 1/4' FILLER FOR 20 GA 3 1/2" METAL STUD BRACING TO 91? CONDITION8'MAX. rMAX. #3082 ROOF STRUCTURE AT 10'-0' OG 70 BUILDING 5TRUGTURE ABOVE FOR MARTIN W. HANSON WALLS LONGER THAN 12'-0" WITHOUT INTERSECTING WALLS. FASTEN EACH m m T END WITH (1) #5 SHEET METAL ° ° OCLA KAM S, OREGON, SGREWWHERE REQUIRED - -- - - - - - - �SUSPENDED CEILING ® �® ° ° `p° �dOF �O BLOCKING TYPICAL AT FASTENING POINTE PROJECT D/'� ►�+ Lp ARi"ISTRONGa BERC2 CLIP O ° o p ARMSTRONG 5ERC2 CLIP ® C1tll�C 112V00 ATTACHED TO GRID UNATTACHED TO GRID 3 1/2" MTL. 5TUD5 24' O.G. 1N REMODEL5 SIZE 5TUD5 TO ALLOW ATTACHED WALL UNATTACHED WALL REUSE 8" MAX ­-14ANGER WIRE W/ STRUT OF BLDG. STD, DOORS AND FRAMES HANGER AND SPLAY WIRES PER w CEILING BRACING DETAIL w5/8' GYP. BRD.BOTH SIDES CENTER LINE OF STUD POP-RIVET GROSS TEE MAIN BEAM CROSS TEE �o o �o oo � aoo � � oo� o00 00 �oo � � �o o � 000c FREE END FIXTED END 4" RUBBER BASE TYP. -I/&' ANGLE MOLDING 1" (FULL 24"TILE SECTION) ATTACH BOTTOM TRACK TO FLOOR WITH POP RIVET 2° 2 ANGLE MOLDING POWDER DRIVEN ANCHORS AT 12" O.C. UNATTACHED THIS SIDE FINISH FLOOR EXPANSION JOINT g NOTE: CEILING SYSTEM TO BE USED SHALL BE CLASSIFIED AS en "HEAVY DUTY'. ALL CONNECTION DEVICES TO BE IBC APPROVED TYPE AND HAVE 1000 CAPACITY 1 TYPICAL WALL SECTION 9 CEILING SEISMIC JOINTS a N A-4 SCALE 1 - 1-0 A-4 SCALE 3 - 1-0 C4 p� BUILT UP ROOF ON W .1a g� DECK a0 w � 20 GA 3 5/5' METAL STUD BRACING R-19 5A77 INSULAT TO ROOF 5TRUGTURE AT 10'-0" OC TO ',�► -..°-� H� �� BUILDING STSRUGTURE ABOVE FOR WALLS LONGER THAN 12'-0" WITHOUT INTERSECTION WALLS. FASTEN EACH I I M CONC.OR BRICK Q END WITH CI) L SHEET METAL SCREW r_AS OCCURS FRAME TO MA CH DOOR V-4 V'476 R-11 BATT INSULATION 4' CENTERED OVER WALL ' PROVIDE HC 51GNAGE 6" 6" FOR ALL NEW AND —SUSP2M - - _ - - ENDED CEILING EXISTING E R NORN R-11 BATT INSULATION FS 25 2._�. 2" KROY 02835201 BLACK(MEN) STICK CLIP ON GONG. WALL —i– KROY $2835209 BLACK(WOMEN) BLOCKING TYPICAL AT FASTENNG POINTS OR EXTEND 5TUD5 W/IN5ULAT10 TO ATTACH STO PANEL 31/2 BATT IN6UL. STO OR BRICK j MEN SUSPENDED CEILING AS OCCURS w / "` ADDITIONAL SWITCH Q W 3 1/2" MTL. STUDS 24' O.G. TI WORK SHELL WORK a �1 GANG LOCATIO ^ ? IN REMODELS SIZE STUDS TO ALLOW REUSEJ 00 a w OF BLDG. STD. DOORS AND FRAMES FLASHING ° �j" z 5/8'GYP.BRD.BOTH SIDES W _ TH 0 � w CENTER LINE OF STUD !� ALUMINUM WINDOW SYSTEMCAULK AT JAM Q v z Q J SHELL WORK �j— � QFLASHING w ELECTRICAL 5/8" GYP � TI WORK OL w STO PANEL OR J-BOX O z R-19 BATT INSULATION O SHELL WORK SHELL WORK I } 4' RUBBER BASE TYP. O i ATTACH BOTTOM TRACK TO FLOOR WITH QAS j ' 0 POWDER DRIVEN ANCHORS AT 12' O.C. UNDERGO?DOOR ,4 © REQUIRED TO CLEAR FIN15H FLOOR FLOOR FINISH A FIN16H FLOOR ------------ O � 2 WALL SECTION WITH SOUND INS. r64 EXTERIOR WALL FURRING DETAIL A 4 MOUNTING,HEIGHTS L SCALE 1 = 1 -0 SCALE 1 1/2 1 0 SCALE 1/2 1 0 � Q 10' MAX SPAN 5/8' PLYWOOD DECK WITH SHEET METAL SCREWS OVER AREA INDICATED ON PLAN -- 6006250-54 METAL STUDS AT 16" O.C., n ALIGN WITH WALL STUDS -®- - - X11- - - oo - - - - - - - - - - - - F.G. INSULATION METAL CEILING STUD LOAD CHART MAX.6PAN 10' TYPICAL STUD MAX.SPACING 161 q MAX.POINT LOAD 315 LB/STUD °� i+> w g 5f8' GYP.B SUSPENDED CEILING v < 4 3625131-33 METAL STUDS AT 16° O.C. SOAP PAPER TOWEL SAN. NAP. PAPER TOWED RECESSED TYPICAL TRACK DISPENSER DISPENSER DISPENSER DISPENSER/ TOWEL ' INSTALL 5TUD5 WITH SAME DISPENSER D IMEN51ON (10" MIN.) FOR BRIDGING ALIGNMENT 5/6" TYP WRGYP. 5/8' GYP.BD. - - - - - - - - - - - - - - W 00 BD. CENTER LINE OF STUD ED 0 V 3-v2' F.G. INSULATION k POWDER DRIVEN k 0 cAll � C4 CIED— (o MIN. 5A5EANCH0R5 AT 12" O.C. 4 n 5EE FINISH 4" RUBBER BASE-TYP. 4 6 0% SCHEDULE ATTACH BOTTOM TRACK TO Iii FOR MATERIAL FLOOR WITH POWDER DRIVEN (1) *10-1(o SCREW 0 Q ANCHORS AT 12' O.C. PER 5TUD FLANGEw FINISH FLOOR SEAT COVER TOIL. PAPER/ GRAB BAR MIRROR O H FIN15H FLOOR-TOP OF SLAB DISPENSER SEAT COV.DISP./ U_ Q SAN. NAP. LU V � RE�JT R®®P'I SIDE OFFICE SIDE DISPOSAL 3 REST ROOM WALL SECTION WALL BASE DETAIL 11 TOILET ROOM ACC. - MOUNTING HEIGHTS � � a C4 P A-4 SCALE 1" = 1'-0" A-4 SCALE 3" = 1'-0" A-4 SCALE. 1/4 - F-0 REVISIONS FLOOR AND/OR ROOF STRUCTURE ARMSTRONG BERC2 CLIP(A5 ALTERNATE MEANS OF CONSTRUCTION Add#1 12/3/12 BLDG. STRICTURE ABOVE FOR THIS PROJECT. Q DEFLECTION CHANNEL ADDITIONAL HANGERS AT ALL MAINS WITHIN 8" OF THE PERIMETERLu RSV#1 12/13/1Z CAULKING IN I/2" SPACE Rev#2 1/10/13 Permit APPROVED VERTICAL STRUT AT 12'-0 O.C.EA.WAY BEGINING WITHIN = R-il BATT INSULATION 6'-0" OF THE PERIMETER OF EACH CEILING SECTION, STRUTS AT FIXTED EDGES NOT ATTACHED TO THE BUILDING TO HAVE 4 WAY LATERAL BRACING FROM THE MAIN RUNNER TO THE BUILDING STRUCTURE ABOVE. SUSPENDED CEILING 6' MTL. 5TUD5 16' O.C. 5/5' TYPE X GYP. BRD, Q BOTH 51DE5 SCREW ATTACHED DRAWN BY: CENTER LINE OF STUD z I R.M.T. 8' CRO55 MEM5ER5 BETWEEN MAIN U MAX RUNNERS DATE: 11/27/12 6'-0" MAX MAIN RUNNERS AT 4'-0' O.C. w SUPPORT WITH *'12 WIRE AT 4'-0° O.C. BID `q U OR WITH "10 WIRE AT 5'-0' O.G. Lu w R-11 BATT INSULATION COUNTER5LOPE HANGERS IF MORE w 4' RUBBER BASE TYP. THAN 1:6 OUT OF PLUMB Lu w ATTACH BOTTOM TRACK TO FLOOR WITH SECURE ALL HANGERS TO BLDG, POWDER DRIVEN ANCHORS AT 24" O.G. STRUCTURE OR A TRAPEZE FOR FINISH FLOOR DUCT AND/OR PIPE WORK NOTE: CEILING 5Y5TEM TO 5E USED SHALL PE CLASSIFIED WAREHOU5E OFFICE 45 "HEAVY DUTY". ALL CONNECTION DEVICES TO 5E IEC APPROVED TYPE AND HAVE 100# CAPACITY 4 OFFICE TO WAREHOUSE SEP. WALL s CEILING BRACING DETAIL A-4 SCALE 1 It = 1'-0" A-`} NOT TO SCALE